Loading...
FW-11-822Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Inspection Number: INSP - 161235 Scheduled Inspection Date: December 05, 2011 Inspector: Bruhn, Norman Permit Number: FW -5 -11 -822 Owner: THE CHURCH OF THE RESURRECTION, Job Address: 456 NE 100 Street Miami Shores, FL 33138- Project: <NONE> Contractor: MCU CONSTRUCTION Permit Type: Fence/Wall Inspection Type: Final Work Classification: Iron/Ornamental Phone Number Parcel Number 1132060170350 Phone: (305)534 -1989 Building Department Comments TWO ALUMINUM PICKETS GATES Failed Correction Needed Re- Inspection Fee No Additional Inspections can be scheduled until re- inspection fee is paid. Inspector Comments CREATED AS REINSPECTION FOR INSP- 161123. Fence exceeds 5' at gate by driveway. Gate a t rear must not have aluminum panel attached. welds are not complete. provide completed welding by a licensed professional. Fence and gates must be painted. C/ December 02, 2011 For Inspections please call: (305)762 -4949 Page 6 of 46 Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 INSPECTION'S PHONE NUMBER: (305) 762.4949 BUILDING PERMIT APPLICATION FBC 20 rtogY 0 2011 J� B Y: °. Permit No. Master Permit No. ` — Permit Type: BUILDING ROOFING OWNER: Name (Fee Simple Titleholder): C13424914 OF 0 '°7 hone #: CS) F(/3-g-7-3 Address: 1)17 3 GU/i i.i(o ALM) City: (S044, AM. 120/4e_. Tenant/Lessee Name: /4 /4- State: Zip: 33 l ipl Phone #: Email: JOB ADDRESS: 1/56 / .g, I b U ,S City: Miami Shores County: Miami Dade Zip: 3313? Folio/Parcel #: Is the Building Historically Designated: Yes NO Flood Zone: CONTRACTOR: Company Name: I _ lC—L.{ C Svu e \ Z'a 1r1 Phone #: 3 1 � � � 1 --1 Address: - (7, %� E A. Ti L L7, i City: 1s / C -e_ (sA 4 6 State: r-10124 ,�_} zip: 33 107 Qualifier Name: �1 i,S'2 (mac a CL 1 Phone #: 3 1S °--CS CI ° 1. Z g 7 State Certification or Registration #: C,� lam' LS { 1 S� Certificate of Competency #: Contact Phone #: Email Address: 0,C. -Y'7 0. QS v" . WW1 DESIGNER: Architect/Engineer: Phone #: Vail o Work f6r this Peru ) lit: $ ' , ( S.--r) , C9-0 Square/Linear Footage of Work: ❑ ew % DRepair/Replace (3 —tLe s ra /v ula P/t u dot Type-of Work: ❑Addition Description of Work: d in pry ❑Alteration ct 1 UDemolition *** ** * ,x,x**** * * **** ***:x******* * *** *** Fees ** * * * * ** * * * ****** * * ***** ** ****x: *x,******* Submittal Fee $ _ ° Permit Fee $ /O7 CCF $ CO /CC $ Scanning Fee $ Radon Fee $ DBPR $ Bond $ Notary $ Training/Education Fee $ Technology Fee $ Double Fee $ Structural Review $ TOTAL FEE NOW DUE $ Co 6- /AO Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Owner or Agent The foregoing instrument was acknowledged before me this 1 day of , 20 .LL, by Signature ._' j4,144 Contractor The foregoing instrument was acknowledged before me this , day of , 20 _, by who is personally known to me or who has produced As identification and who did take an oath. NOTARY PUBLIC: Jose Area DD792227 M Y 27, 2012 My Commission Expires: oa> who is personally known to me or who has produced as identification and who did take an oath. °Mrs J098 P �1t� ',1153.3 "i i$t:)079222 ,i %SPY27,20'1; Sign `;' y +yy AA R: NIOTARYcelQ Print: jbse 4 rfze My Commission Expires: NOTARY PUBLIC: **** * * * * * * * * * * * * * * * **** * **** *** ** x****** ********* ******* *+x+x+x:x:x***+r********** APPROVED BY 'V/ / Plans Examiner Structural Review (Revised 07 /10 /07)(Revised 06 /10/2009)(Revised 3/15/09) -z-A * * * * * * * * * * * * * * * * * * * * * * * * * * ** 176/// Zoning Clerk 1 Miami Shores Village APPROVED BY ZONlNG DEPT BLDG DEPT St 111,11 CT TO COMM IANCE WITH ALL FEDERAL RI A FE AND CntlNI TY RULES AND REGULATIONS A das 1- 0 • at LLX „ • 1,41) Os° — )-- 0.17; 0 BY! roaaa■ ******* 0 000 0•Oed AS • N3#0 ' N. dip v?,/orff,,)", ; 2qej F:102 Departments \06 Sateguards109 Steel -Iron Fence or Rails1SKU 5203 - Welded Steel Fencing MPS (2007 FBC).dwg 05/04/2011 - 12:37pm Kat AT GRADE STEEL FENCE SCALE: N.T.S. 2" X 2" X 14GA POST 1" X 2" X 16GA RAILS 1 "X1 "X 16GA PICKET 1 7/8" -r •- 3 7187-7 • - BOTTOM RAIL CONCRETE FOOTING WELL COMPACTED SOIL v -a 1 6" \ \ / J /` /\ � % / \� \�/ \ MATCHING GATE PICKET THRU RAIL 48" & FULLY WELDED \ice \.� \.�\ LATCH - (SEE NOTES) GRADE NOTE: N /1" X 2" X 16GA RAIL 16GA PICKETS- UGA 14GA " HINGE (MAY VARY) , - ACCESS LATCHES TO GATES REQUIRED TO / PROTECT POOL MUST BE AT LEAST 48" ABOVE GRADE & EQUIPPED WITH A SELF CLOSING, SELF LATCHING LOCKING DEVICE NOT LESS THAN 54" FROM BOT-OF-GATE. GATE MUST OPEN OUTWARD AWAY FROM POOL & MUST HAVE NO OPENING - - >1/2 WITHIN 18" OF RELEASE MECHANISM. 2 "X2 "X14GA. POSTS FULLY WELDED CONNECTION (TYP.) .1-41" T N 1 RAIL 16GA DRAWING VALID ONLY WITH ORIGINAL SIGNATURE AND RAISED SEAL. VALID FOR (1) LOCATION PER SEALED DRAWING FRANK L. BENNARDO, P.E1 # PE0046549 GENERAL NOTES 1. THIS SYSTEM HAS BE NE DE-SIGN€DiND SHALL BE FABRICATED IN ACCORDANCE-WITH THE REQUIREMENTS;OF THE 2007 FLORIDA BUILDING CODE WITH`2009 SUPPLEMENTS. 2. DESIGN`BASED ON�ASCE 7-05 USING V = 90MPH (3 SEC GUST, UP TOa6' -2t IN,1HVHZ),AND 140MPH(3;JSEC GUST, BEYOND 6' -2" AND OUTSIDE HVHZ), EXPOSURE 'C', CATEGORY I (I = 0.77), USING THE 'OPEN�SIGN METHOD'. 80% OPEN USSED I V CALCULATIONS. 3. HIS FENCE DESIGN TO BE USED AT GROUND SURFACE ONLY, WITH USE LIMITED TO. DECORATIVE BARRIER PURPOSES ONLY. THIS FENCE IS NOT INTENDED ;TO MEET CODES GOVERNING ELEVATED BALCONIES OR STRUCTURAL-RAILINGS. 4. ALL COMPONENTS TO BE FULLY WELDED GALV. STEEL USING A36 STEEL 0.063" WIRE MINIMUM W/ YIELD STRENGTH 36KSI OR BETTS . _ 5. ALL CONCRETE AND EPDXY TO REACH A MIN. COMPRESSIVE STRENGTH OF 3600 PSI IN 7 DAYS. CONCRETE FOOTERS SHALL CONTAIN MINIMUM 0.1% FIBER MESH CONTENT PER CUBIC YARD. 6. SURROUNDING SOIL TO BE COMPACTED TO 98% OPTIMUM DENSITY, 2500 PSF MIN. 7. PER FBC 424.2.17.1.8: POOL ACCESS GATES WHEN PROVIDED MUST BE AT LEAST 48" ABOVE GRADE & EQUIPPED WITH A SELF CLOSING, SELF LATCHING LOCKING DEVICE NOT LESS THAN 54" FROM BOT OF GATE. GATE MUST OPEN OUTWARD AWAY FROM POOL & MUST HAVE NO OPENING >1/2" WITHIN 18" OF RELEASE MECHANISM. 8. THE CONTRACTOR IS RESPONSIBLE TO INSULATE ALUMINUM MEMBERS FROM DISSIMILAR METALS TO PREVENT ELECTROLYSIS. 6. ALL WELDING MUST BE DONE BY AN AWS CERTIFIED WELDER OR SHALL CONFORM TO AISC STEEL CONSTRUCTION MANUAL 13TH ED AS INSPECTED AND VERIFIED BY OTHERS. MIN. WELD IS Y" FULL FILLET WELD. 7. ELECTRICAL GROUND, WHEN REQUIRED, TO BE DESIGNED & INSTALLED BY OTHERS. 8. ANY HINGE AND LATCH SHALL BE STRUCTURAL QUALITY MOLDED POLYMERS OR ZINC COATED METALS AND SHALL BE INSTALLED PER MANUFACTURER'S RECOMMENDATIONS & ANY APPLICABLE CODES. 9. ENGINEER SEAL AFFIXED HERETO VALIDATES STRUCTURAL DESIGN AS SHOWN ONLY. USE OF THIS SPECIFICATION BY CONTRACTOR, et. al. INDEMNIFIES & SAVES HARMLESS THIS ENGINEER FOR ALL COST & DAMAGES INCLUDING LEGAL FEES & APPELLATE FEES RESUL G FROM MATERIAL FABRICATION, SYSTEM ERECTION-CONSTRUCTION P -ES BEYOND THAT WHICH IS CALLED -FORBY LOCAL, STATE, & FEDERAL ODES & FROM DEVIATIONS OF.THIS -PLAN 10. ENGINEERING SS HAS NOT VISITED THIS JOBSITE. INFORMATION HEREIN IS BASED ON CONT TRACTOR SUPS? ED /DATA AND MEASUREMENTS. ENGINEERING EXPRESS SALLNO�BE HELD RESPONSIBLE OR LIABLE IN ANY WAY FOR ERRONEOUS OR IINACCURATEDATA OR, MEASUREMENTS. DIMENSIONS AR SHOWN TO ILLUSTRATEDESIGN FORCES AND OTHER DESIGNCRITERIA. tHEY,MAY VARY SLIGHTLY, BUT MUST REMAIN WITHIN THE - LIMITATIONS SPECIFIED HEREIN. WORK SHALL BE FIELD VERIFIED�BY OTHERS PRIOR TO CONSTRUCTION. BE FIELD t I '\ L 1. OTHERS � TO ENGINEERING EXPRESSDHALL BE PTI , ED'IAND`GIVEN AN OPPORTUNITY TO REEVALUATE OUR WORK UPON 'DISCOVERY OF ANY INACCURATE INFORMATION PRIORTO1MODIFICATION OF EXISTING FIELD CONDITIONS AND FABRICATION AND INSTALLATION OF MATERIALS. 11. EXCEPT AS EXPRESSLY PROVIDED HEREIN, NO ADDITIONAL CERTIFICATIONS OR AFFIRMATIONS ARE INTENDED. CD Z _ O N M Q 4;Ax WN =u- u ZW z 6LL 6 NQ W 1 W o '-W oW.-. t0 1.1.1 .. U W J W 1- U) c J W 3 2 2 LL lSg§ O 1111 Pk?g � COPYR1GHTFRAMC L BENNARDO PE 5203 SCALE: NTS - 101 PAGE DESCRIPTION: f OF I1 BOUNDARY SURVEY t LOT 19 LOT 18 5' WOOD FENCE EAST 1/2 LOT 3 LEGEND. FND - FOUND CM - CONCRETE MONUMENT IR - IRON ROD IP - IRON PIPE ROW - RIGHT OF WAY POD - POINT OF BEGINNING POC - POINT OF COMMENCEMENT PC - POINT OF CURVE POC - POINT ON A CURVE -. -• CHAIN LINK FENCE -i-- - !FOOD FENCE PR - PLAT BOOK P - PAGE M - MEASURED D • DEED R • RADIUS A - ARC D • CENTRAL ANOLE C • CHORD - ELEVATION - I---I- NON- VEHICRLAR ACCESS LINE - CONCRETE -U- • OVERHEAD L1V - PAVERS • TILE 0- MAtwOLE 1-.I -TREE 16.4' 87.5' 5.0' SWY 17.0' PARKWAY ro WEST 37.5' LOT 5 FNO I/2- IP NO ID --Q NE 100 STREET(75.0' TOTAL ---- - - - - -- 30' ASPHALT PAVEMENT SKETCH OF SURVEY SCALE. 1. • 20' GENERAL NOTES! 1) BASIS OF BEARZNOt AS PER PLAT 2) ELEVATIONS SHOWN HEREON ARE RELATIVE TO NATIONAL GEODETIC VERTICAL DATUMCN.O.V.O.) 31 LOCATION AND IDENTIFICATION OF UTILITIES ON AND/OR ADJACENT TO THE PROPERTY WERE NOT SECURE AS SUCH INFORMATION WAS NOT REQUESTED. 4) NOT VALID WITHOUT THE SIGNATURE AND THE ORIGINAL RAISED SEAL OF A FLORIDA LICENSED SURVEYOR AND MAPPER. 5) THIS SURVEY IS NOT INTENDED FOR CONSTRUCTION PURPOSES 6) ENCROACHMENTS AND VIOLATIONS ON SURVEY(IF ANY11 LEGAL DESCRIPTION EAST 12.5 FEET LOT 5. ALL LOT 4 & WEST 112 LOTS IN BLOCK $9 OF MIAMI SHORES SEC 4 ACCORDING TO THE PLAT THEROF AS RECORDED IN PLAT BOOK 15 AT PAGE 14 OF THE PUBLIC RECORDS OF MIAMI-DADE COUNTY. FLORIDA. CERTIFICATION OF I HEREBY CERTIFY RESPONSIBLE M AND BELIEF, THIS STAND -r• S S LAND S,y •CODE �1iT TO BOUNDRY SURVEY. THAT THIS SURVEY WAS MADE UNDER MY TQ'THE BEST OF MY KNOWLEDGE Y MEETS THE MINIMUM TECHNICAL H BY THE: BOARD OF PROFESSIONAL APTE'R 61017 -6 FLORIDA ADMINISTRATIVE N 472.027.• FLORIDA STATUTES. JULIO I ..L.S. PROFE ONAL LAND SURVEXOR LICENSE N0. PSM 5789 STATE OF FLORIDA J.S.P. SURVEYORS. INC. LAND SURVEYORS LB • 6971 7805 CORAL WAY, SUITE 116A MIAMI, FLORIDA 33155 PHONE, (786) 236 8344 SECTION: 33-56- 39 COUNTY: DADE CERTIFIED TO: THE CHURCH OF THE RESURRECTION 456 NE 100 STREET. MIAMI SHORES. FL DATE: 3/25/ 1 1 I REF: 1 1 - 03- 13 DeD:GL 1 1082 C:\Or1 ~vines \G_11082.dgr 3/27!2011 3:01:48 PM Jun. 17. 2011 10:18AM No. 5343 • it41?0$174q E: • pAlpy.„ .;;;; T.N. LL,c Jr:10E100EL (1.0Cik QUALIFIER • OLbk:,1?&LMA.-Itttla5-..;- : . 1 • t sr, (71 Jun. 17. 2011 10:18AM r1 ,�CC?RD CERTIFICATE OF LIABILITY INSURANCE No. 5343 P. 2 ASRLL -1 OP ID: IZ DATE (MM@P/YYYYI 06/09/11 PRODUCER InS0ur08, inc. 9800 South Dadeland Blvd.,#400 P.O. Box 561567 Miami, FL 33258 -1587 Devon!. Mimics 306. 970.6111 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES_BELOW. INSURERS AFFORDING COVERAGE NAM # INSURED ASR Interiors, LLC 42202 Fisher IslandnDrive Fisher Island, FL 33109.1288 INSURERA: Starr Indsmnl y & Liability Co INSURERS: Crum & Forster Indemnity Co 38318 31348 INSURERC: Evanston Insurance Company INSURERA INSURER E: COVERAGES THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS. EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. AGGREGATE LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR • AUDI , n :,. • • . , . POLICY NUMBER POUCYEFFECTIVE .: .. +�L POLICY EXPIRAII•N • .. LIMITS A GENERAL SIPGQL00116 -00 03/13/11 1 03/13/12 HpSCCURRENCE $ 1,000,000 X COMMERCIAL GENERAL LIABILITY j PRRFMEf o nca) $ 50,000 1 CLAIMS MADE X OCCUR MED EXP (My one person) $ 6,000 PERSONALSAOVINJURY $ 1,000+000 GENERAI.AGGREGATE $ 2,000,000 GENT. AGGREGATE LIMIT APPLIES PER: PRODUCTS - COMP/OP AGO 2,000,000 PODGY X PRM' n LOC AUTOMOBILE — — — LIABILITY ANYAUTO ALL OWNED AUTOS $CHEDULEDAUTOS HIREDAUTOS NON-OWNEDAUTOS • COMBINED SINGLE LIMIT (Eaecddenp S BODILY INJURY (Perpereon) $ BODILY INJURY (Per S PROPERTY IPAMAC E (Peracddenl S GARAGE UABIU?Y H ANY AVID AUTO ONLY .EAACCIDENT 5 OTHER EAACO s ON A00 S C EXCSSS 1OCCUR /Vseste4ALIABILITY XOMW226711 01/26/11 01/26/12 EACH OCCURRENCE _ $ 2,000,000 CLAIMSMAOs AGGREGATE $ 2,000,000 — X DEDUCTIBLE RETENTION $ 5 S $ 13 WORKERS AND EMPLOYERS, ANY PROPRIETOR/PARTNER/EXECUTIVE OFFICER/MEMSER (Mandatory reyee describe SPECIAL PRO\/ISIONSDelow COMPENSATION LIABIUTY Yi 14 405400255.5 06/23/10 X ■ 0,FI EXCLUDED? 06/23/11 E,L,EAcHACCIDENT s 1,000,000 lnNH) under E.L. DISEASE. EA EMPLOYEE 5 1,000,000 5.1. DISEASE- POLICY LIMIT S 1,000,000 OTHER - DESCRIPTION OF OPERATIONS / LOCATIONS / VEHICLES / EXCLUSIONS ADDED BY ENDORSEMENT 1 SPECIAL PROVISIONS 90 days written notice of cancellation for non- payment of premium. CANCELLATION Miami Shores Building & Zoning 10050 N.E. 2nd Avenue Miami Shores, FL 33138.2304 ACORD 26 (2008/01) MIAM099 SHOULD ANYOF THE ABOVE OESCReED POLIO SBEOANCELLEDeEFOHETHEEXPIRATION DATE THEREOF, THE ISSUING INSURER WILL ENDEAVOR TO MAIL 30 . DAYS WRITTEN NOTICE 70 THE CERTIFICATE HOLDER NAMED TO THE LEFT, BUT FAILURE TO 00 50 SHALL IMPOSE NO OBLIGATION OR LIABILITY OF ANY KIND UPON THE INSURER, ITS AGENTS OR REPRESENTATIVES. AUTHORIZED REPRESENTATIVE ®1988.2000 ACORD CORPORATION. All rights reserved. The ACORD name and logo are registered marks of ACORD Jun. 17. 2011 10:19AM No. 5343 P. 3 ASRLL -1 OP ID: IZ IMPORTANT If the certificate holder is an ADDITIONAL INSURED, the policy(ies) must be endorsed. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require en endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). DISCLAIMER This Certificate of Insurance does not constitute a contract between the Issuing Insurer(s), authorized representative or producer, and the certificate holder, nor does it affirmatively or negatively amend, extend or alter the coverage afforded by the policies listed thereon. ACORD 25 (2009/01)