Loading...
RF-11-1645Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Inspection Number: I NSP- 164934 Scheduled Inspection Date: October 03, 2011 Inspector: Bruhn, Norman Owner: YVEL, ARMAND Permit Number: RF -9 -11 -1645 Job Address: 138 NW 106 Street Miami Shores, FL 33150- Project: <NONE> Contractor: DEL SOL ROOFINGENTERPRISE INC Permit Type: Roof Inspection Type: Final Roof Work Classification: Flat Phone Number (407)427 -1657 Parcel Number 1121360080040 Phone: (305)229 -5722 Building Department Comments RE ROOF ON FLAT ROOF Passe• Z [Z( Failed Correction Needed Re- Inspection Fee No Additional Inspections can be scheduled until re- inspection fee is paid. Inspector Comments CREATED AS REINSPECTION FOR INSP- 164221. Provide renail affidavit. NB September 30, 2011 For Inspections please call: (305)762 -4949 Page 17 of 29 Miami Shores Village Building Department RE: Permit # cam \ \- \ >1 INSPECTION AFFIDAVIT (Print name and circle License Type) License #: • 3 & On or about (Date & time) Secondary water barrier work at i 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 DATE: \ 1 to 1 \ licensed as a (n) Contractor / Engineer / Architect, FS 468 Building Inspector , I did personally inspect the roof deck nailing and \ 0 6) �� - Based upon that examination I have determined the installation State of Florida County of Dade: (Complete Job Site Address) was done according to the Hurricane Mitigation Retrofit The undersigned, being the first duly swom, deposes and says that he /she is the contractor for the above property mentioned. Sworn to and subscribed before me this day of Notary Public, Sate of Florida at Large AotY PuB`, DENA RODRIGUEZ • * MY COMMISSION # EE 033658 EXPIRES: Navetnbor 30, 2014 '4,t,,,,e1 Op Sanded TIN Budget *fay Semites `General, Building, Residential, or Roofing Contractors or any individual certified under 488 F.S. to make such an inspection. Include photographs of each plane of the roof with permit # and address # clearly shown marked on the deck for each inspection Revised on 5/21/2009 RE: Permit #‘K C Miami Shores Village Building Department INSPECTION AFFIDAVIT (Print name and circle License Type) License #: °S` Cob 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 7952204 Fax: (305) 756.8972 DATE: licensed as a (n) Contractor / Engineer / Architect, FS 468 Building Inspector On or about 1 1 1 In 11 , I did personally inspect the roof deck nailing and (Date & time) Secondary water barrier work at 1 S� (Complete Job Site Address) Based upon that examination I have determined the installation was done according to the Hurricane Mitigation Retrofit Manual (Based on 55 844 F 4 9111°1° Signatur State of Florida County of Dade: The undersigned, being the first duly swom, deposes and says that he/she is the contractor for the above property mentioned. Swom to and subscribed before me this /.5 day of ;- r Zd�'� Notary Public, Sate of Florida at Largo DMA RODRIG(JQ M" COMMISSION # EE 03308 EXPIRES Nyvember 30, 2414 Banded Thor Budset Notary Sewioes *General, Building, Residential, or Roofing Contractors or any individual certified under 468 F.S. to make such an inspection. Include photographs of each plane of the roof with permit # and address # dearly shown marked on the deck for each inspection Revised on 5/21/2009 r • •• Cl\\ ,Devo BUILDING PERMIT APPLICATION FBC 20 Permit Type: BUILDING ROOFING Miami Shores Village 13°/331V31 Building Department SEP 0 7 2o,t 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 INSPECTION'S PHONE NUMBER: (305) 762.4949 BY: 000011O000 400 0000000000 RtiPermit No. Master Permit No. OWNER: Name (Fee Simple Titleholder): °C �*,� `°I N) Phone #: Address: ` -1 L cAe. City:��� ® State: Zip: Tenant/Lessee Name: Phone #: Email: JOB ADDRESS: I .ss 1-v ► 0 & . City: Miami Shores County: Miami Dade Zip: .331 S Folio/Parcel #: % 1— Z. \ 3 b- 00 g- 0 0 Li Is the Building Historically Designated: Yes NO Flood Zone: CONTRACTOR: Company Name: �\ %c�\ 0 0 CI � G1 Phone #: O 5 - 2: 0 21 Address: .1 S 1® IA i Li 14 91 ‘ City: \ ' `► ; State: Qualifier Name: p�, -e '�, � ��� State Certification or Registration #: Contact Phone #: DESIGNER: Architect/Engineer: Zip: -3 1 Phone #: Certificate of Competency #: 0 6 -Z� Email Address:c.-,&,z,\c itt.�k..:aN-\C-.1 �CA. Cy, 'C.—CA-TN • Phone #: Value of Work for this Permit: $ 2® � Type of Work: DAddition ❑Alteration Description of Work:�� Square/Linear Footage of Work: 't ❑New %421Repair/Replace ❑Demolition ***:x********a **** : *******:x **** **** ** *Fees******************************************** '1"k Submittal Fee $ Permit Fee $a CCF $ CO /CC $ Scanning Fee $ Radon Fee $ DBPR $ Bond $ Notary $ Training/Education Fee $ Technology Fee $ Double Fee $ Structural Review $ TOTAL FEE NOW DUE $ 9al ' Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOTI.F.RS, HEATERS, TANKS and AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Contractor The foregoing ins ment was acknowledged before me this S 9 The foregoing instrument was acknowledged before me this 3 A day of 11,e ow 20 % a , by _ , day of �a1C���, 20 b ®, by who is personally known to me or who has produced who is personally known to me or who has produced As identification and who did take an oath. as identification and who did take an oath. NOTARY PUBLIC: Sign: c �' Print: My Commission Expires: APPROVED BY Dena RODRIGWZ * MY COMMISSION # EE 033$58 EXPIRES: November 3:; 2 i 144 044 < Bolded TIw WO Mary $en tee NOTARY PUBLIC: Sign- '���e-� Print: *Pt: P , DMA RODRIGUEZ My Commission Expires . * COMMISSION # EE ,201 EXPIRES: November 30, 2014 �t9�or ,too, Boded Thu Budget Notary Setnees 6 t `t/ Plans Examiner Zoning Structural Review Clerk (Revised 07 /10 /07)(Revised 06 /10/2009)(Revised 3/15/09) Miami Shores Vivage Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 OWNERS'S AFFIDAVIT OF EXEMPTION ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR EXISTING SITE - BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES PERSUANT TO SECTION 553.844 F.S. To: Miami Shores Village Building Department 10050 NE 2nd Ave Miami Shores, Fl 33138 Re: Owner's Name: s-c Date: Property Address: t `J ciS N ► \ D Roofing Permit Number: Dear Building 0 cial: I NV1 certify that I am not required to retrofit the roof to wall connections of my building because: to The just valuation for the structure for purpose of ad valorem taxation is less than $300,000.00. Please attach proof of ad valorem taxation. ❑ The building was constructed in compliance with the provisions of the Florida Building Code (FBC) or with the provisions of 1994 edition of the So : I II a Building Code (1994 SFBC) Signature iA ryAavtot Y. Yve.L Print Name State of Florida County of Dade The undersigned, being the first duly swom, deposes and says that he /she is the owner for the above property mentioned. Swom to and subscribed before me this -3 \ day of '..c.;,1' `A‘ ` 2 D i 1 Notary Public, Sate of Florida at Large— _�-- ���` ✓'% DE NIA RODRIGUEZ MY COMMISSION# EE 033658 EXPIRES: Numbs( 30,2014 Bonded T m End Nay Semis • When the just valuation of the structure for purpose of ad valorem taxation is equal to or more than $300,000.00, and the building was not constructed with FBC nor a 1994 SFBC. Then you must provide a building application from a General Contractor for the Roof to Wall connection Hurricane WGtigation. Revised on 5/21/2009 Miami Shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 CONTRACTORS' REGISTRATION FORM ALL CONTRACTORS MUST PROVIDE COPIES OF LICENCES AND INSURANCES EACH TIME A PERMIT IS SUBMITTED OR THE VILLAGE MAY MAINTAIN A FILE WITH YOUR INFORMATION FOR A $30.00 FEE PER YEAR. IF CONTRACTOR IS A FLORIDA STATE CERTIFIED CONTRACTOR: A. \ COPY OF QUALIFIER'S STATE LIC CARD B. \A COPY OF LOCAL BUSINESS TAX RECEIPT C. N COPY OF LIABILITY INSURANCE (CERTIFICATE HOLDER TO BE MIAMI SHORES VILLAGE BLDG DEPT) D. \ COPY OF WORKERS COMPENSATION (EITHER CERTIFICATE OR EXCEMPTION) IF CONTRACTOR HAS A MIAMI DADE COUNTY CERTIFICATE OF COMPETENCY: A. COPY OF CERTIFICE OF COMPETENCY OF QUALIFIER B. COPY OF MIAMI DADE COUNTY MUNICIPAL CONTRACTOR'S TAX RECEIPT C. COPY OF LIABILITY INSURACE (CERTIFICATE HOLDER MUST BE MIAMI SHORES VILLAGE BLDG DEPT) D. COPY OF WORKER COMP INSURANCE (EITHER CERTIFICATE OR EXEMPTION) YOUR INSURANCE COMPANY MUST ISSUE A CERTIFICATE HOLDER AS FOLLOW: MIAMI SHORES VILLAGE BLDG DEPT 10050 NE 2ND AVE MIAMI SHORES, FL 33138 COMPLETE CONTRACTOR'S INFORMATION BUSINESS NAME: =\ (ttb■ BUSINESS ADDRESS: °1 S-1 r °� v� ' \ \ `\ CITY e STATE \ ZIP CODE BUSINESS PHONE: (3 0 S) --z-Z °t-a'M FAX NUMBER (St S) CELL PHONE ( ) QUALIFIER'S NAME: L, �:r.—\*iN�� QUALIFIER'S LIC NUMBER: \ 3 2 tc 1 E -MAIL ADDRESS (IF APPLICABLE): ' -e\ N Created on 3119109 BY MLDV 1 RV 3126109 MLDV STATE OF FLORIDA DEPARTMENT OF BUSINESS AND PROFESSIONAL REGULATION CONSTRUCTION INDUSTRY LICENSING BOARD 1940 NORTH MONROE STREET TALLAHASSEE FL 32399 -0783 PACHECO, LISSETTE DEL SOL ROOFING ENTERPRISE INC 2525 W 3 CT HIALEAH FL 33010 Congratulations! With this license you become one of the nearly one million Floridians licensed by the Department of Business and Professional Regulation. Our professionals and businesses range from architects to yacht brokers, from boxers to barbeque restaurants, and they keep Florida's economy strong. Every day we work to improve the way we do business in order to serve you better_ For information about our services, please log onto www.myftoridaticense.com_ There you can find more information about our divisions and the regulations that impact you, subscribe to department newsletters and learn more about the Department's initiatives. Our mission at the Department is: License Efficiently, Regulate Fairly. We constantly strive to serve you better so that you can serve your customers. Thank you for doing business in Florida, and congratulations on your new license! DETACH HERE (850) 487 -1395 LATE BATCH t J'flEER' MIAMI -DADE COUNTY TAX COLLECTOR 140 W. FLAGLER ST. 1st FLOOR MIAMI, FL 33130 585464 -2 A Qty ou N ssSuUL RIOFIN6 ENTERPRISE INC 2011 LOCAL BUSINESS TAX RECEIPT 2012 MIAMI -DADE COUNTY - STATE OF FLORIDA EXPIRES SEPT. 30, 2012 MUST BE DISPLAYED AT PLACE OF BUSINESS PURSUANT TO COUNTY CODE CHAPTER 8A - ART. 9 & 10 T 14;;. I :1 NOT A SILL -- 50 NOT PAY pp RENEWAL STATE IEE1�S2573b 610526 -6 7570 NW 14 ST 33126 MIAMI OWNER DEL SOL ROOFING ENTERPRISE INC Sec�r96 SPECIALTY BUILDING CONTRACTOR THIS IS ONLY 6A LOCAL BUSINESS TAX RECEIPT. tT DOES NOT PERMIT THE HOLDER TO VIOLATE ANY EXISTING REGULATORY OR ZONING LAWS OF THE COUNTY OR CITIES. NOR DOES IT EXEMPT THE HOLDER FROM ANY OTHER PERMIT OR LICENSE REQUIRED BY LAW. THIS IS NOT A CERTIFICATION OF THE HOLDERS QUALIFICA- TIONS. PAYMENT RECEIVED MIAMI•DADE COUNTY TAX COLLECTOR; 07/19/2011 60000000182 000045.00 SEE OTHER SIDE • FIRST -CLASS U.S. POSTAGE PAID MIAMI, FL PERMIT NO. 231 WORKER /S 8 DO NOT FORWARD DEL SOL ROOFING ENTERPRISE INC DANIEL DEL SOL PRES 7570 NW 14 ST MIAMI FL 33126 11, 111 11 11,1,111111,1,111111111i111111u 11,1111111�l111} 111 09/02/2011 16:24 FAX 3052691108 DELTA INSURANCE UND. IJ001 /002 A °) CERTIFICATE OF LIABILITY INSURANCE �``°�°I;Y"' THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POUCIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSUREDS), AUTHORIZED REPRESENTATIVE OR PRODUCER, AND THE CERTIFICATE HOLDER. - IMPORTANT: If the corti (cats holder is an ADDITIONAL INSURED, the po-llcy((es) musFbe endorsed. If SUBROGATION IS WAIVED, subject to the tam and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer ruts to the certificate holder In Iteu of such endorsement(s). PRODUCER DELTA INSURANCE UNDERWRITERS, INC. 777 N.W. 7 AVENUE, SUITE 3193 MIAMI, FLORIDA 33128 1 LUIS DE LA LLERA t'' e E«>k 305- 289.1107 1 liriallo 305-269-1108 App; DELTAINSUND@AOLCOM INSURERS) AFFORDING COVERAGE RAC* INSURER SCOTTS[)ALE INSURANCE COMPANY 41297 INSURED DEL SOL ROOFING ENTERPRISE. INC. 7570 N.W. 14 STREET, SUITE 111 MIAMI, FLORIDA 33128 PH 305 228 0218 FAX 305 229 5722 INSURER IT: ' CPS1420044 INSURER : • 08/09/2012 INSURERD; - INSURERE: - - $ 100,000. INSURER F : - I -MADE ►I OCCUR CERTIFICATE NUMBER REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POUCIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. - SHOULD ANY OF THE ABOVE DESCRIBED POUCIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DEUVERE D IN ACCORDANCE WITH THE POLICY PROVISIONS. TYPE OF e13URpNCE INSR MOD POLICY NUMBER ( p1YYYi LaBTs A GENERAL 7 LIABILITY CO{ 1AL GENERAL LIABILITY CPS1420044 08/0912011 08/09/2012 EACH OCCURRENCE $ 1,000,000. PREMISES � ) $ 100,000. I -MADE ►I OCCUR MED EXP (Any one person) $ 5,000. PERSONAL aADVINJURY $ 1,000,000. GENERAL AGGREGATE • $ 2,000,000. GEN'L AGGREGATE LIMIT APPLIES PER: f POLICY JJECT n LOC PRODUCTS • COMPIOP AGO $ 1,000,000. - $ AUTOMOBILE UAEILI1Y ANY AUTO AUTOS NEO I= HIRED AUTOS EN AUTOS A ED NON -OWNED AUTOS 4ED SINGLE LIMIT $ ��LYINJURV(Perpe:son) $ BODILY INJURY (Per accident $ 'KOPr= R:YDAMAGE (Peracdde:H) $ IAA.kA UAB EXCESS LWS °CCUR CLAIMS-MADE , EACH OCCURRENCE $ AGGREGATE $ DED 'WORKERS $ COMPEL aA AND EMPLOYERS' LIABILITY Y/ N ANY ER NIA !WON •TUU.. (TORY UMITS� �fO� I E L. EACH ACCIDENT $ B �CU FFIC EXCLUDED? yes. describe In under DESCRIPTION OF OPERATIONS below DISEASE- EA EMPLOYE $ EL. DISEASE - POLCY LIMIT $ DESCRIPTION OF OPERATIONS I LOCATIONS / VEHICLES (ANedt ACORD 101, Additional Remarks $cheduue, Nmore space le requked) CONTRACTORS LICENSE NUMBER CCC1328657. i_RBTICIHA m ism nee MIAMI SHORES VILLAGE / BUILDING DEPT. 10050 N.E. 2nd AVENUE MIAMI SHORES, FLORIDA 33138 PH 305 795 2204 FAX 305 756 8972 I ACORD 25120101e51 SHOULD ANY OF THE ABOVE DESCRIBED POUCIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DEUVERE D IN ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED R SENTATIVE 4 1 mil a LUIS DE LA LLERA 1988 2010 /CORD CORPORATION. All rights reserved. The ACORD name and logo are registered marks of ACORD 09/01/2011 1:38:34 PM —0400 FRSA Self Insurers Fund 1111(fRS A ISSUED TO: PAGE 1 OF 1 Issue Date: 9/1/2011 FLORIDA ROOFING, SHEET METAL & AIR CONDITIONING CONTRACTORS ASSOCIATION, INC. SELF INSURERS FUND 1 -800- 767 -3772 • FAX (407) 671 -2520 CERTIFICATE OF INSURANCE Miami Shores Village Building Department 10050 NE 2 Avenue Miami Shores, FL 33138 Attention: Del Sol Roofing Enterprises, Inc. This is to Certify that: 7570 N.W. 14th Street, #111 Miami, FL 33126 COPY PROVIDED TO: Del Sol Roofing Enterprises, Inc. 7570 N.W. 14th Street, #111 Miami, FL 33126 being subject to the provisions of the Florida Workers' Compensation Act, has secured the payment of compensation by insuring their risk with the FLORIDA ROOFING, SHEET METAL & AIR CONDITIONING CONTRACTORS ASSOCIATION SELF INSURERS FUND, P.O. Box 4907, Winter Park, FL 32793. COVERAGE NUMBER: 870 - 033587 EFFECTIVE DATE: 1/19/2011 EXPIRATION DATE: 1/1/2012 LIMITS Workers' Compensation: Statutory - State of Florida Employers' Liability: $100,000.00 Each Accident $100,000.00 Disease, Each Employee $500,000.00 Disease, Policy Limit REMARKS: Non - cancelable, without 30 days prior written notice, except for non - payment of premium which will be a 10 day written notice. Lissette Pacheco as Qualifier, License #CCC1328657 This certificate is issued as a matter of information only, is not a policy and of itself does not afford any insurance. Nothing contained in this certificate shall be constructed as extending coverage not afforded by the policy(ies) shown above or as affording insurance to any insured not named above. This provides coverage for Florida policyholders and Florida domiciled employees only. By: By: Brett Stiegel, Administrator Debra Guidry, CPCU, Un•erwriting Manager SECTION R4402.13 HIGH VELOCITY HURRICANE ZONES — REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS R4402.13.1 Scope. As it pertains to the section, it is the responsibility of roofing contractor to provide the owner with the required roofing permit, and to explain to the owner the content of the section. The provisions of Section R4402 govem the minimum requirements and standards of the industry for roofing system installations. Additionally, the following items should be addressed as part of the agreement between the owner ant the contractor. The owner's initial in the designated space indicates that the item has been explained. 1. min Aesthetics- Workmanship: the workmanship provisions of Section R4402 are for the purpose of providi that the roof system meets the wind resistance and water instruction performance standards. Aesthetics (appearance) are not a consideration with respect to workmanship provisions. Aesthetic issues such as color or architectural appearance, that are not part of a zoning code, should be addressed as part of the agreement between the owner and the contractor. 2. AFl Renailing wood decks: When replacing roofing, the existing wood roof deck may have to be renailed in accordance with the current provisions of Section R4403. (The roof deck is usually concealed prior to removing the existing roof system). 3. Aftl Common roofs: Common roofs are those which have no visible delineation between neighboring units (i.e., townhouses, condominiums, etc.) In buildings with common roofs, the roofing contractor and/or owner should notify the occupants of adjacent units of roofing to be performed. 4. Exposed Ceiling: Exposed, open beam ceilings are where the underside of the roof decking can be vie ed from below. The owner may wish to maintain the architectural appearance; therefore, roofing nail penetration of the underside of the decking may not be acceptable. This provides the option of maintaining the appearance. 5. r, F i Ponding water: The current roof system and /or deck of the building may not drain well and may cause ater to pond (accumulate) in low -lying areas of the roof. Pounding can be an indication of structural distress and may require the review of a professional structural engineer. Pounding may shorten the life expectancy and performance of the new roofing system. Pounding conditions may not be evident until the original roofing system is removed. Pounding conditions should be corrected. 6. ,n Overflow scuppers (wall outlets): It is required that rainwater flows off so that the roof is not overlo'. • ed from a buildup of water. Perimeter /edge wall or other roof extension may block this discharge if overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in accordance with the requirements of Sections R4402, R4403 and R4413. 7. Law Ventilation: Most roof structures should have some ability to vent natural airflow through the interio` of the structure assembly (the building itself). The existing amount of attic entilation shall not be reduced. It may be beneficial to consider additional venting which can re " ; ' endin,> e service life of the roof. f g. 21-23n6 Owner /Ag: nt's Signature Date Revised on 7/9/2009 LD Contractor Signat - a Date 9 -‘ 6' ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Florida Building Code Edition 2007 High - Velocity Hurricane Zone Uniform Permit Application Form. Section A (General Information) Master Permit No. Process No. Job Address � l� (o:› S1 Low Slope ❑ Mechanically Fastened Tile ❑ Mortar /Adhesive Set Tile ❑ Asphaltic ❑ Metal PaneUShingles ❑ Wood Shingles /Shakes Shingles Contractor's Name ❑ Prescriptive BUR -RAS 150 ROOF TYPE ❑ New Roof N Reroofing ❑ Recovering ROOF SYSTEM INFORMATION ❑ Repair ❑ Maintenance Low Slope Roof Area (SF) Steep Sloped Roof Area (SF) Total (SF) y aO Section R (Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. APPROVED ••• ••• „ M. PT II • • • • •• • ••• •• • • • •• • • • • • • • • OfIr FLORIDA BUILDING CODE — BUILDING e • • ••••DATE SUBJECT TO COMPLIANCE WITH ALL FEDERAL STATE AND COUNTY RULES AND REGULATIONS ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Florida Building Code Edition 2007 High - Velocity Hurricane Zone Uniform Permit Application Form. , Surfacing: Section C (Low Slope Application) Fill in specific roof assembly components and identify manufacturer (If a component is not used, identify as "NA ") System Manufacturer: G X=N- Product Approval No.: 0 q — 0 Z v—A 01 Design Wind Pressures, From RAS 128 or Calculations: Pmax1:"-i,Ci 2- Pmax2: -. Pmax3: Z-\ Max. Design Pressure, from the specific Product Approval system: S 2. 5 Deck: Type: �� Gauge!Thickness: 4 g Slope: Anchor /Base Sheet & No. of PIy(s): Anchor /Base Sheet Fastener /Bondin Insulation Base Layer: Base Insulation Size and Thickness: Base Insulation Fastener/Bonding Ma erial: Top Insulation Layer: Top Insulation Size and Thickness: \' Nc› Top Insulation FastenerlBonding Material: Base Sheet(s) & No. of Piy(s): 7 c `\CD Bev Sh t FastenerlBonding aterial: Ply Sheet(s) & No. of PIy(s) ubeS ©o 2.0 Ply Sheet Fasten r /Bondi g Materia • Top Ply: V-A \•4 Top Ply Faste er /Bonding Material: FLORIDA BUILDING CODE — BUILDING Fastener Spacing for Anchor /Base Sheet Attachment: Field: -1 " oc @ Lap, # Rows2-- @q / oc Perimeter: "' " oc @ Lap, # Rowsy @ " oc Corner: 40 " oc @ Lap, # Rows L-1 @ C " oc Number of Fasteners Per Insulation Board: Field.i� 4�� Perimeter t Comer Illustrate Components Noted and Details as Applicable: Woodblocking, Gutter, Edge Termination, Stripping, Flashing, Continuous Cleat, Cant Strip, Base Flashing, Counter - Flashing, Coping, Etc. Indicate: Mean Roof Height, Parapet Height, Height of Base Flashing, Component Material, Material Thickness, Fastener Type, Fastener pacing or Submit nLN.\ 9" c 3Y, 3 •.A• • •••• • • ••. • • • •• • . • • • • • • • • • • • •• • Parapet Height •••• • • • • • Mean •.Reof • .Weight • •••• • • 000 • ••• • • • •• • • • •••••• • • • • ••• • • MIA MMADE BUILDING CODE COMPLIANCE OFFICE (BCCO) PRODUCT CONTROL DIVISION NOTICE OF ACCEPTANCE (NOA) GAF Material Corporation 1361 Alps Road Wayne, NJ 07470 ° MIAMI -DADE COUNTY, FLORIDA METRO -DADE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 MIAMI, FLORIDA 33130 -1563 (305) 375 -2901 FAX (305) 375 -2908 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by the BCCO and accepted by the Building Code and Product Review Committee to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AI-13 may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Division that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code and the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: GAF RUBEROID® Modified Bitumen Roof System for Wood Decks. LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOtt pp* endorsement of any product, for sales, advertising or any other purposes shall autonagteic4Ily terpiin to this NOA. Failure to comply with any section of this NOA shall be cause for termin tiAn.and rerfatvat of • NOA. • ••.• •••• ADVERTISEMENT: The NOA number preceded by the words Miami -Dade* Cm-Ay, Floreiaisap and followed by the expiration date may be displayed in advertising literature. If any •popic of tht•N•O4 is displayed, then it shall be done in its entirety. • • •••••• • INSPECTION: A copy of this entire NOA shall be provided to the user by the mabufactiurer o, �t,�.; disl, ibutors and shall be available for inspection at the job site at the request of the$uijdipg Official. •• • • • This NOA revises NOA No. 07- 1203.01 and consists of pages 1 through 31. The submitted documentation was reviewed by Jorge L. Acebo. • NOA No.: 09- 0224.01 Expiration Date: 11/06/13 Approval Date: 04/08/09 Page 1 of 31 • •• •••••• • • • • • • • • • • ROOFING SYSTEM APPROVAL Category: Sub - Category: Material: Deck Type: Maximum Design Pressure Roofing Modified Bitumen SBS /APP Wood -75 psf TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Product Leak BusterTM Matrix"' 307 Premium Asphalt Primer GAF Mineral Shield® Granules Leak BusterTM MatrixTM 305 Fibered Asphalt Emulsion Leak BusterTM MatrixTM 303 Premium Fibered Aluminum Roof Coating LeakBusterTM MatrixTM 322 Elastomeric Roof Coating LeakBusterTM MatrixTM 306 LeakBusterTM MatrixTM 204 Wet/Dry Roof Cement GAFGLAS® #75 Base Sheet GAFGLAS® #80 ULTIMATM Base Sheet GAFGLAS® Flex P1yTM 6 GAFGLAS® Ply 4 GAFGLAS® Mineral Surfaced Cap Sheet Test Dimensions Specification 5, 55 gallons ASTM D41 60 Ib. Bags ASTM DI863 100 Ib. bags 5 gallons 1, 5 gallons 55 gallons 55 gallons 1, 5 gallons 39.37" (1 meter) Wide 39.37" (1 meter) Wide 39.37" (I meter) Wide 39.37" (1 meter) Wide 39;37" (I meter) Wide ASTM D1227 Product Description Asphalt concrete primer used to promote adhesion of asphalt in built -up roofing. Granules for surfacing of exposed asphalt, cold process cement or emulsion. GAF Mineral Shield® Granules shall be used for flashing applications only. Surface coating for smooth surfaced roofs. ASTM D 2824 Fibered aluminum coating. ASTM D3019 ASTM D3409 ASTM D4586 ASTM D3409 ASTM D4601 ASTM D4601 ASTM D2178 ASTM D2178 ASTM D3909 Elastomeric roof coating. Asphalt emulsion fibered. Refined asphalt blended with a mineral stabilizer and fibers. Permits adhesion to wet and dry surfaces. Type II Asphalt isnpregnated arrd coated glass mat base sheet. • • • • • • • •••• Type II Asphalt impregnated and Coated, fiberglass base shoe! • • • • • • •' • • •••• •••• Type VI asphalt impregnated glass flit with asphalt coating. • • Type IV asphalt iroptvgQated glass' felt with asphalt coatifig. • • Asphalt coated, glistarr mat cap gheet surfaced with mineral granules. • • • •••••• • • NOA No.: 09- 0224.01 Expiration Date: 11/06/13 Approval Date: 04/08/09 Page 2 of 31 • • • • • • • Product GAFGLAS ®EnergyCapTM Mineral Surfaced Cap Sheet GAFGLAS® EnergyCapTM BUR Mineral Surface Cap Sheet GAFGLAS® STRATAVENT® EliminatorTM Perforated GAFGLAS® Flashing GAFGLAS® STRATAVENT® EliminatorTM Perforated Nailable RUBEROID® SBS Heat- We1dTM Smooth RUBEROID® SBS Heat- We1dTM Granule Roof MatchTM SBS Mop Granule RUBEROID® SBS Heat- We1dTM 170 FR RUBEROID® SBS Heat- We1dTM PLUS RUBEROID® SBS Heat -Weld T"" PLUS FR RUBEROID® EnergyCap SBS Heat- WeIdTM PLUS FR RUBEROID® Modified Base Sheet RUBEROID® SBS Heat- WeIdTM 25 MIAM4DADECOUNTY APPROVED Dimensions 39.37" (1 meter) Wide 39.37" (1 meter) wide 39.37" (I meter) Wide various 39.37" (1 meter) Wide 1 meter (39.37 ") wide 1 meter (39.37 ") wide 107 sq. ft. (9.9 m2) 1 meter (3937 ") wide 1 meter (39.37 ") wide 1 meter (39.37 ") wide 1 meter (39.37 ") wide 39.37" (1 meter) Wide 1 meter (39.37 ") wide Test Specification ASTM D3909 ASTM D3909 Energystarm Title 24 Compliant ASTM D3672 ASTM D4897 ASTM D3672 ASTM D4897 ASTM D6164 ASTM D6164 ASTM D6222 ASTM D5147 ASTM D6164 ASTM D6164 ASTM D6164 ASTM D6164 ASTM D4601, Type II, UL Type G2 BUR ASTM D6164 Product Description Asphalt coated, glass fiber mat cap sheet surfaced with mineral granules with factory applied layer of TOPCOAT® EnergyCoteTM. Asphalt coated, glass fiber mat cap sheet surfaced with mineral granules with factory applied EnergyCoteTM Fiberglass base sheet coated on both sides with asphalt. Surfaced on the bottom side with mineral granules embedded in asphaltic coating with factory perforations. Asphalt coated glass fiber mat flashing sheet available in three sizes. Fiberglass base sheet coated on both sides with asphalt. Surfaced on the bottom side with mineral granules embedded in asphaltic coating. Non -Woven Polyester mat coated with polymer - modified asphalt and smooth surfaced. Non -Woven Polyester mat coated with polymer modified asphalt and surfaced with mineral granules. Non -woven polyester mat coated with polymer modified asphalt and surfaced with colored mineral granules. Non -Woven Polyester mat coated with fire retardant polymer modified asphalt and surfaced with mineral granules. Non -Woven Polyester mat coated ; ith polymer modified asphalt and•aCed • with mineral gramepg. ; . • • • • Non -Woven Polye,iteraaat coateawrith • • • • • • fire retardant polynae; +Modified asphalt • .. • • and surfaced with1miier,a1 graattl .• . ..... A fiberglass mat relilfo*ced, SB$•modified • • bitumen cap memt ra . . n. e.• • • • . •. Premium glass fibDr r8in2orced•SBS• modified base sheet • • •• • .. • • Non -Woven Polyester mat coated with polymer - modified asphalt and smooth surfaced. • NOA No.: 09-0224.01 Expiration Date: 11/06/13 Approval Date: 04/08/09 Page 3 of 31 • • Product RUBEROID® Mop Granule RUBEROID® MOP Smooth RUBEROID® MOP PLUS RUBEROID® MOP 170FR RUBEROID® MOP FR RUBEROID ® TORCH Smooth RUBEROID® TORCH Granule RUBEROID ® EnergyCap Torch Granule FR Roof MatchT' APP Torch Granule RUBEROID® TORCH PLUS RUBEROID® TORCH FR RUBEROID® 170FR TORCH RUBEROID® EnergyCap SBS Heat Weld Plus FR RUBEROID® 20 RUBEROID® 30 Dimensions 39.37" (1 meter) Wide 1 sq. roll 87 lbs. 39.37" (1 meter) Wide 39.37" (1 meter) Wide 39.37" (1 meter) Wide 39.37" (I meter) Wide 39.37" (1 meter) Wide 1 meter (39.37 ") wide 107 sq. ft. (9.9 m2) 39.37" (1 meter) Wide 39.37" (1 meter) Wide 39.37" (1 meter) Wide 1 meter (39.37 ") wide 39.37" (1 meter) Wide 39.37" (1 meter) Wide Test Specification ASTM D6222 ASTM D5147 ASTM D6298 ASTM D5147 ASTM D6164 ASTM D5147 ASTM D6164 ASTM D5147 ASTM D6164 ASTM D5147 ASTM D6222 ASTM D5147 ASTM D6222 ASTM D5147 ASTM D6222 ASTM D5147 ASTM D6222 ASTM D5147 ASTM D6222 ASTM D5147 ASTM D6222 ASTM D5147 ASTM D6222 ASTM D5147 ASTM D6163 ASTM D5147 ASTM D6163 ASTM D5147 ASTM D6163 ASTM D5147 Product Description Non -woven polyester mat coated with polymer modified asphalt and surfaced with mineral granules. Non -woven polyester mat coated with polymer - modified asphalt and smooth surfaced. Non -woven polyester mat coated with polymer modified asphalt and surfaced with mineral granules. Non -Woven polyester mat coated with fire retardant polymer modified asphalt and surfaced with mineral granules. Non -Woven polyester mat coated with fire retardant polymer modified asphalt and surfaced with mineral granules. Heavy duty, polyester reinforced, asphalt modified bitumen membrane, smooth surface. Heavy duty, polyester reinforced, asphalt modified bitumen membrane, granule surface. A fiberglass mat reinforced, SBS modified bitumen cap membrane. Non -woven polyester mat coated with polymer modified asphalt and surfaced with colored mineral granules. Heavy duty, polyester reinforced, asphalt modified bitumen membrane, granule surface Heavy duty, polyester reinforced, coated with fire retardant asphalt modified bitumen membrane, granule snrfat; Heavy duty, polytsteicginforcet•d'oated •• with fire retardanttasphdlt mo4ified. • bitumen membra te,'gr'h?iule surface. • A fiberglass mat reinforced, SBAAppdified..•.. bitumen cap membge„• • ••.• ••;••• ••• • SBS modified asphaftbase sheet reinforce °°°° • • with a glass fiber Iraq*: Non woven fiberglass mat coatideitlli polymer modified place and surfaced with mineral granules. NOA No.: 09 -0224.01 Expiration Date: 11/06/13 Approval Date: 04/08/09 Page 4 of 31 • Product RUBEROID® 30 FR RUBEROID®EnergyCap SBS 30 FR RUBEROID® ULTRACLAD® SBS RUBEROID® Dual FR Vent Stacks (metal and plastic) GAF Built -Up Roofing Asphalt RUBEROID® MOD Asphalt Asphalt L & Asphalt P TOPCOAT® Surface Seal SB LEAK BUSTERTM MatrixTM 715 MB Elastomeric Roofing Membrane EnergyCoteTM Coating VersaShield® TOPCOAT® FireShield® MB Leak BusterTM MatrixTM 531 WeatherCoteTM Elastomeric Flashing Grade LeakBusterTM MatrixTM 201 Premium SBS Flashing Leak BusterTM MatrixTM 102 SBS Adhesive Label Dimensions 39.37" (1 meter) Wide 1 meter (39.37 ") wide 39.37" (1 meter) Wide 39.37" (1 meter) Wide 100 Ib. cartons, bulk 60 Ib. kegs 5 gallons 5 gallons 2, 5 gallons 350 sq. ft roll 5, 55 gallons 5 gallons 5 gallons 5 gallons Test Specification ASTM D6298 ASTM D5147 ASTM D6163 ASTM D6163 ASTM D5147 ASTM D6164 ASTM D5147 TAS I00(A) ASTM D1929 ASTM D635 ASTM D312, Types I, II, III and IV ASTM D3412 ASTM D21 ASTM D1475 ASTM E1644 ASTM D6083 ASTM -D226 4869 Type I, II ASTM D412 ASTM D21 ASTM 1475 ASTM E1644 ASTM D3019 ASTM D3019 Product Description Non woven fiberglass mat coated with fire retardant, polymer modified asphalt and surfaced with mineral granules. A fiberglass mat reinforced, SBS modified bitumen cap membrane. Woven fiberglass mat coated with Polymer modified asphalt surfaced with aluminum, copper or stainless steel foil. Non -woven polyester and fiberglass mat coated with file retardant, polymer - modified asphalt and surfaced with mineral granules. One -way valve vent used to relieve built - up pressure within the roof system. GAF Vent Stacks are available in metal or plastic. Interply mopping and surfacing asphalt SEBS modified asphalt Surface coating for smooth surfaced and mineral surfaced roofs. Surface coating for smooth surfaced and mineral surfaced roofs. Highly reflective elastomeric coating Non - Asphaltic Fiberglass - Based, • Underlayment • • • •••• Elastomeric roofing p erilbrane• • • •••.•• • •••• • .... .••• • • • • • Surface coating for S55th surf .igd apd mineral surfaced roofs. • • • • •• •• •• ..•.• • • • • . • Cold Applied Modified SEBS AtflIrts Adhesive — Flashing,•ad@. • • Cold Applied Modified SEBS Asphalt Adhesive. NOA No.: 09- 0224.01 Expiration Date: 11/06/13 Approval Date: 04/08/09 Page 5 of 31 •••••• • • • •.•..• • • •••••• • • •.••• • • .••.• •.•••• • •• • • • • Product Leak BusterTM Matrix 202 SBS Flashing Cement Label Leak BusterTM MatrixTM 203 Plastic Roof Cement Label Leak BusterTM MatrixTM 103 Cold Process Adhesive Label LeakBusterTM MatrixTM 304 Non -Fibered Aluminum Roof Leak BusterTM MatrixTM 602 MB Xtra Elastomeric Roofing Membrane TOPCOAT® MB Plus Dimensions 5 gallons 5 gallons 5 gallons 5 gallons 5 gallons 5, 55 gallons Test Specification ASTM D4586 ASTM D4586 Product Description Cold Applied Modified SEBS Asphalt Adhesive — Flashing Grade. Standard Plastic Asphalt Roofing Cement ASTM D3019 Cold Applied Asphalt Adhesive. ASTM D2824, Type 1 ASTM D412 ASTM B117 ASTM C794 ASTM G21 FTMS141.6271 ASTM D2196 ASTM D1475 ASTM E1644 ASTM D412, ASTM D21, ASTM D1475 ASTM E1644 Non- fibered. Aluminum pigmented, asphalt roof coating. Surface coating for smooth surfaced and mineral surfaced roofs. Water - based, low VOC, sprayable polymeric liquid, which cures to form a seamless rubber membrane. • • • • • •• • • • • • • • •• •• •0000• • • • • • • • • .• • •.. • • • • •• • • • •••• • •0•• • • •••• ••• • • • • • •• • • 000000 • NOA No.: 09-0224.01 Expiration Date: 11/06/13 Approval Date: 04/08/09 Page 6 of 31 00••00 • • • ••••.. • • •0•••• • • • • • • • • • APPROVED INSULATIONS: Product Name EnergyGuardTM Fiberboard EnergyGuardTM Permalite EnergyGuardTM Strip EnergyGuardTM Recover Board EnergyGuardTM Tapered Edge Strip EnergyGuardTM PolyIso EnergyGuardTM RA, RN EnergyGuardTM Composite, RA DensDeck® DensDeck Prime® DensDeck DuraGuardTM Structodek® Structodek® TD SecurockTM APPROVED FASTENERS: Fastener Product Number Name 1. Drill-TecTM #12 Standard, #14 and #15 extra Heavy Duty Fastener, Heavy Duty Roofing Fastener 2. Drill-TecTM ASAP 3. Drill-TecTM CR Base Sheet Fastener and Plate 4. Drill-TecTM Galvalume Plates 5. Drill -TecTM Polypropylene Plates 6. Drill -TecTM AccuTrac Plate Table 2 Product Description Fiberboard insulation Perlite insulation board Cut perlite board Perlite recover board Tapered perlite board Polyisocyanurate foam insulation Polyisocyanurate foam insulation Polyisocyanurate /wood fiberboard or perlite composite Water resistant gypsum board Water resistant gypsum board Water resistant gypsum board Wood fiber insulation board Flame Resistant High Density Wood Fiber board. Fiber reinforced roof board TABLE 3 Product Description Insulation fastener and Base Play fastener for steel, wood & concrete decks. Pre- assembled Drill -TecTM Fasteners and metal and plastic plates. Base sheet fastening assembly. Round Galvalume stress plates. Round polypropylene stress plates. Square Galvalume® coated steel plate. Dimensions Various Various Various 3" and 3 %2" 3" and 3'' /2" 3" Square Manufacturer (With Current NOA) GAF Materials Corp. GAF Materials Corp. GAF Materials Corp. GAF Materials Corp. GAF Materials Corp. GAF Materials Corp. GAF Materials Corp. GAF Materials Corp. G -P Gypsum Corp. G -P Gypsum Corp. G -P Gypsum Corp Knight Celotex Knight - Celotex USG Corporation Manufacturer (With Current NOA) GAF Materials Corp. • . GAF Materialreorp. • • • • •• •• • • • • •••• • '".AV Material§ iorp. •••• • . • •••• •••• ••• • • • • • •• •• •• .40,, .Materials Corp. • • • • • • • • • 3A4'Materials Corp. •• • • OMG NOA No.: 09- 0224.01 Expiration Date: 11 /06/13 Approval Date: 04 /08/09 Page 7 of 31 • • • •••••• • • • • .•••• • • • • • • EVIDENCE 1DENCE S lJ BMIT 1 ED: Test Agency Test Identifier Description Date Factory Mutual Research Corp. Underwriters Laboratories 3029832 4470 -TAS 114 05/11/07 3010215 4470 - TAS 114 03/01 /01 3001276 4470 - TAS 114 01/28/99 1B9A8.AM 4470 - TAS 114 09/04/97 3D4Q2.AM 4470 - TAS 114 04/30/97 ODIA8.AM 4470 - TAS 114 04/01/98 TGFU.R19254 UL 790 10/27/06 Trinity Engineering 4483.04 97 -1 TAS 114 06/06/97 PRI Asphalt Technologies, Inc. GAF - 020 -02 -01 ASTM D 249 02/01/02 ASTM D 4977 IRT -ARCON Inc. 02 -005 TAS 114 03/01/02 02 -014 TAS 114 04/08/02 01 -039 TAS 114 03/01/02 Trinity J ERD G6850.08.08 ASTM D6164 08/29/08 G6850.08.08 ASTM D6163 08/01/08 G6850.10.08 ASTM D6222 10/06/08 G6850.11.08 ASTM D6222 11/05/08 • • • • •• • • •••• • • •••• • • •• •• • • • • • • • • • • •••• • •• • • • • •••• • • ••• • • • • • • • • • • NOA No.: 09- 0224.01 Expiration Date: 11/06/13 Approval Date: 04/08/09 Page 8 of 31 • • • • • • 00000 • • • • • • • • Membrane Type: Deck Type 1: Deck Description: System Type E(1): All General and Fire Barrier: (optional) Base sheet: Fastening Options: SBS /SBS Cold Applied Wood, Non-insulated 19/32" or greater plywood or wood plank decks Base sheet mechanically fastened to roof deck. System Limitations shall apply. FireOutTM Fire Barrier Coating, VersaShield® Non-Asphaltic Fiberglass -Based Underlayment or SecurockTM. GAFGLAS® #80 ULTIMA TM Base Sheet, STRATAVENT® Eliminator"' Nailable, RUBEROID® Modified Base Sheet, RUBEROID® 20, RUBEROID® SBS Heat- WeidTM Smooth or RUBEROID® SBS Heat- We1dTM 25 base sheet mechanically fastened to deck as described below; GAFGLAS® Ply 4, GAFGLAS® Flex PIyTM 6, GAFGLAS® 1175 Base Sheet or any of above Base sheets attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" o.c. at the lap staggered and in two rows 12" o.c. in the field. (Maximum Design Pressure —45 psf, See General Limitation #7) GAFGLAS® Ply 4, GAFGLAS® Flex PIyTM 6, GAFGLAS® #75 Base Sheet or any of above Base sheets attached to deck with Drill-TecTM #12 standard, #14 or # 15 Screws and 3" Drill -TecTM steel plate or Drill -TecTM AccuTrac Plates, 12" o.c. in 3 rows. One row is in the 2" side lap. The other rows are equally spaced approximately l 2" o.c. in the field of the sheet. (Maximum Design Pressure —45 psf, See General Limitation #7) GAFGLAS® Flex PIyTM 6, GAFGLAS® #75 Base Sheet or any of above Base sheets attached to deck with approved annular ringihank nails and tin caps at a fastener spacing of 9" o.c. at the 4" Iap staggered and in two rows 9" o.c. in the field. (Maximum Design Pressure —52.5 psf, See General Limitation #7) GAFGLAS® #80 ULTIMATM, RUBEROID®20, RUBEROID® Mop Smooth, base sheet attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" o.c. at the 4" lap staggered and in two rows 9" o.c. fl t1 • field. •••• • • • • • (Maximum Design Pressure —60 p • •• sf, See General Limitation • ii7) • • • GAFGLAS® #75 Base Sheet or any of above Base sheets attae1 ed to deck with Drill -TecT' #12 standard, #14 or # 15 Screws and 3" Drill- Teem's$ael plat 83 • Drill-Teem AccuTrac Plates, 12" o.c. in 4 rows. One row' is in tiie 2" side•Jp. • • • The other rows are equally spaced approximately 9" o.c. in th s fiejiptif the sheet. (Maximum Design Pressure —60 psf, See General Limitation] Z). • • • • • Any of above Base sheets attached to deck approved annular ling sjiank nati?s$nd 3" inverted Drill -TecT' insulation plates at a fastener spacing•gi9" b.c. at the 4i' lap staggered in two rows 9" in the field. (Maximum Design Pressure —60 psf, See General Limitation 117) • • • • • • • • • NOA No.: 09- 0224.01 Expiration Date: 11/06/13 Approval Date: 04/08/09 Page 27 of 31 • • • • • GAFGLAS® #75 Base Sheet or any of above Base sheets attached to deck with Drill -TecTM #12 standard, #14 or # 15 Screws and 3" Drill -TecTM steel plate or Drill -TecTM AccuTrac Plates, 8" o.c. in 4 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 9" o.c. in the field of the sheet. (Maximum Design Pressure —75 psf, See General Limitation #7) Ply Sheet: (Optional) One or more plies GAFGLAS® PLY 4, GAFGLAS® Flex P1yTM 6, GAFGLAS® #80, RUBEROID® MOP Smooth or RUBEROID® 20 sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. Membrane: One or more plies of RUBEROID® MOP Smooth, RUBEROID® Mop 170 FR, RUBEROID® Mop Granule, Roof MatchTM SBS Mop Granule, RUBEROID® Mop Plus Granule, RUBEROID®20 RUBEROID®30, RUBEROID®EnergyCap SBS 30 FR RUBEROID®0 R or RUBEROID® Mop FR or RUBEROID ULTRACLAD® SBS in adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs. /sq. Or, One or more plies of RUBEROID® MOP Smooth, RUBEROID® Mop Granule, Roof MatchTM SBS Mop Granule, RUBEROID® Mop 170 FR, RUBEROID® Mop Plus Granule, RUBEROID®20, RUBEROID® 30, RUBEROID EnerN ap SBS 30 FR, RUBEROID® 30 FR or RUBEROID® Mop FR or RUBEROID" ULTRACLAD® SBS in Leak Buster" MatrixTM 102 SBS Adhesive at an application rate of 1 -2 gal. /sq. Surfacing: (Optional, required if RUBEROID® MOP Smooth or RUBEROID® 20 is top membrane) Install one of the following: Gravel or slag applied at 400 lbs. /sq. and 300 lbs. /sq. respectively in a flood coat of approved asphalt at 60 lbs. /sq. or applied in a flood coat of Leak BusterTM MatrixTM 103 Cold Process Adhesive applied at a rate of 3 gal. /sq. GAFGLAS® Mineral Surfaced Cap Sheet, GAFGLAS® Energy Cap Mineral Suomi aced Capsheet adhered i a ll mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs. /sq. Leak BusterTM Matrix "303 Premium Fibered Aluminum Roof Coating, at 1.5 gal. /sq. Maximum Design Pressure: e •• Leak BusterTM Matrix" 715, Leak BusterTM Matrix" 322, TQPCO..' MB +, TOPCOAT® Fireshield Elastomeric Roofing Mentbale `.applietd its op 1.5 gal. /sq. •••• Leak BusterTM MatrixTM 602 MB Xtra Elastomeric Roofiri•lkembrane.„.. EnergyCotee roof coating applied at 1 to 1.5 gal. /sq. •.... • • ,,• • • TOPCOAT® Surface Seal, TOPCOAT® Fireshield® SB Sett ttased' • • ■• Elastomeric Roofing Membrane applied at Ito 1.5 gal. /sq•' " • Advance Green Technologies Photovoltaic Laminate solal ever& coilggyr; auxiliary roof equipment installed in compliance with mai ufa*twer's • specifications and applicable Building Codes. • 11 • ' • See Fastening above NOA No.: 09 -0224.01 Expiration Date: 11/06/13 Approval Date: 04/08/09 Page 28 of 31 • • •.•.•• • • • • • 11.4••• . • • • • • • WOOD DECK SYSTEM LIMITATIONS: 1 A slip sheet is required with Ply 4 and Flex Ply TM 6 when used as a mechanically fastened base or anchor sheet. 2. Minimum ''A" Dens Deck or V2" Type X gypsum board is acceptable to be installed directly over the wood deck. GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance, refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbsisq., or mechanically attached using the fastening pattern of the top layer 3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size shall be 4' x 4' maximum. 4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at each side lap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 12 lbs. /sq. Note: Spot attached systems shall be limited to a maximum design pressure of -45 psf. 5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F') value of 275 lbf., as tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field - tested, are below 275 lbf. insulation attachment shall not be acceptable. 6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing, prepared, signed and sealed by a Florida Registered Engineer, Architect, or Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117. 7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 117. Calculations prepared, signed and sealed by a FlojdMistered Professional Engineer, Registered Architect, or Registered Roof Consultant CW1I,&b this dilatation • is •• specifically referred within this NOA, General Limitation #9 will not be appli able) • •;,..' ... e • • • 8. All attachment and sizing of perimeter nailers, metal profile, and/or flashing termijt ippdesigns shall • • • • • conform to Roofing Application Standard RAS 111 and applicable wind load requi tints. •.•••• • • 9. The maximum designed pressure limitation listed shall be applicable to all roof presstxe zones (+.t! • field, ":' • • perimeters, and comers). Neither rational analysis, nor extrapolation shall be pennitittd•f {r enhaf184d fastening at enhanced pressure zones (i.e. perimeters, extended corners and corners)' (When this 1 imitation .' is specifically referred within this NOA, General Limitation #7 will not be ap'irtca{;e.) • • ....: • 10. All products listed herein shall have a quality assurance audit in accordance with the Florida BU'ilding Code' • • and Rule 9B-72 of the Florida Administrative Code. '. • • • • END OF THIS ACCEPTANCE NOA No.: 09- 0224.01 Expiration Date: 11/06/13 Approval Date: 04/08/09 Page 31 of 31 ROOF COVERING MATERIALS (TEVT) Roofing Systems. (TGFU)– Continued ASP11ALT.FEI.T SYSTEMS WITH HOT ROOFING ASPHALT Type �G�2qasps glass mat base sheet ("GAFGLAS #7 -.Base Sheet" or "GA-`�"-""' #�-U1,7)7)fg )1s -a suitable altecltate for Type Wilt a � glass fiber ply sheet ('GAFGLAS Y l' „ 6 ". -m the C -18SS C roof The systems indica ted below • cA iTaal gg Ost k,ayre redw h a •Type G2 asphalt: glass n?at base Shea . "GAPStratav�itt.Elimuralor Tenting•Base B '(Perforated) or: "GAF " �n Base Sheet (Naiable)"` : Perforated 'to be Strataveat Ehutmatoi`-Venng coo find iiailabre'fri be inedfanicallp'attached granule side don PPS mat base sheet ( "GAFGLAS #75 Base As an o hoer . G2 asphalt 81a �s Sheer, " LA tM, #80 UI,1TMA• or "GAF SdrataireotEtiminator Venting Base • Sheet (NailableY' may be substituted for G1 asphalt g)'ass- fiber ply sheet CGAFGLAS plY 4 ° "G.A.FG AS Ply. 6"; ) as the nafd base-ply in the following sys Bottom ply or-base.sheet May be solid mopped, spot mopped or inechani- Unless otherwise indicated, all :insulations may. be hotmopped or rriechani- cally_ .... „GAFGT-, g" or "x„bePia" may used for flashing in, any: of the Class•A. B-oris Nelc — " Wiien, "peclte!s refeiencedlids includes GAFLIIy1I P ®" or any other-UL Classified perlite insulation. ' . - • : 1. • Cnished stone -or slakare suitable alternates for. gravel in any of the Class A, B or C • Struuhiral cem build unity ate considered suitable to be included B or Csystems listed. over C- -15/32 or-NC as a deck lit ttie .-' CIass"A, B.or C systems '3he use.of gyipsirmp��� alt :.Qf tfie Waxing sy' does not adve y ef%ct thre AIMS- acceptable altemalg: for ' Lion ruler - 15/32 decks. The use of pb1.. ation board between min 3/4 in . to board Poma pa : rosin / l ,Mite) is a and deck mth rosin apex' �Cper']ite7 � ` ' , P� ppoo Y Pm' suitable alternate for " isocyanurafe- board m the. following. Class A, B or C hoard .• syste " itic ape l > ergyct are RA'' and "BMCA `"jGuard •.. "may tie sutirrartitt ite,d for. any Atlas polyisocyanurate insnla- 11 Of the fo11Q'winS Uas ifiCahons.. . IT• ,y "pe,j)op may be utilized with any of the following "Asphalt Felt Systems. with fiot R.00&ng . Asphalt". GAFGI.AS #!O Premium lie_ 5 may be used in any of the .flowing systems, . . _ "GAFGLAS Fiex Piy 6" is a suitable alternate to "GAFGLAS Ply 6 ". "GAF TEMP Rentable Recover Board" may be used in lieu of any perlite insulation in any of the following NC Classifications. • Class A, B and C Tl�e use of 1/2 in. min gypsum board is-an Hot roofing asphalt, for use with organic and glass fells or modified bitumen membranes. "Ruberoid Heat Weld" SBS roofing membrane may be used in lieu of "Ruberoid Mop" SBS products in any applicable Classification Class A 1. Deck: C -15/32 Incline 3 Insulation (Optional): One or more layers perlite, wood fiber, glass fiber, isocyanurate, urethane, perlite /isocyanurate composite, perlite/ urethane composite, woodfiber /?socyarlurate composite, Phenolic, any thicCa s>.:: .. Pik Sheet : Three or, more layers T }ape. Gl• "GAFGLAS. • Ply 4" or "GAFGLAS Ply 6 ", hot mopped.. • . Surfacing Gravel 2. Deck C -15/32 Indium 2 Insulation (Optional): One or more layers perlite, wood fiber, glass fiber, isocyanurate, urethane, perlite/isocyanurate composite, perlite/ urethane composite, wood fiber/isocyanurate composite, phenolic, any thickness. Ply Sheet Three or more layers Type Gi "GAFGLAS Ply 4" or "GAFGLAS Ply 6 ". Cap Sheet One layer Type G3 "GAFGLAS Mineral Surfaced Cap Sheer. 3. Deck: NC Incline 2 Insulation (Optional): One or more layers perlite, wood fiber, glass fiber, isocyanurate, urethane, perlite/isocyanurate composite, perlite/ :ethane composite, wood fibeer /isocyanurate composite, phenolic, 2 in. max. Ply Sheet Two or more layers Type GI "GAFGLAS Ply 4" or "GAF - GLAS Ply 6 ". Cap Sheet One Layer Type G3 "GAFGLAS Mineral Surfaced Cap Sheet". 4. Deck NC Incline: 1/2 Insulation: One or two layers "Isotherm R ", 4 in. max, hot mopped. ROOF COVERING MATERIALS (TEVT) 173 Roofing S �n ued .. Ply sheet -Any UL Classified gravel surfilted am A asp,* *SS fiber incline: i :. Deck C- 15/3'2. . Slip Sheet t , ::• ,.. , •papez.nailed to deck Base Sheet One la er at ey . #75 Base Sheet" (may be nailed) Ply Sheet'Ctne or more layera•Typpe GGl /'G� 1Ply 4`• or �' 'LAs Ely Cr°. neral Surfaced Ca Cali Sheet:, One layer Type- Type- G-3 `•GAFGI.AS- . Mi P 6. tear NC :.. Base Sheet One layer Type G2 "GAFGLAS #75 Base Sheer.:. . Ply Sheet One or more.layers Type G1 "GAFGLAS Ply 4" or. "GAF- GLAS Ply 6 ". - .. • Cap. Sheet One - Layer Type:,G -3 "GAFGLAS Mineral. Surfaced Cap Sheet" •- • :. 7. Deck C -15/32 Incline: 2 • Tnsirlation;. One or. more layers perlite, glass fiber, isocyanurate, ure- thane; perlite/isocyanurate cginposite, perlite /urethane composite, phe- nolic, 1.0 in. min (of 'set fro A Plywood joints 6 Base Sheet Oaw or more layers Type GI, G2•or G3. • Membricri One or mine layers• "Ruberout•Tbrdr" (Smooth or Granule), - "Rubergfd Torch-Plus" (granule); "Ruben: id Mop" (Smooth or Granule) or•'Ruberoid Mop Plus" (granule). Sheet; hot mopped. Cap Sheet: "GAFGLAS Mineral Surfaced Cap pP $. Deck 0-15/3V- " . • - • Incline 2 ' : • it sulatioh ( tfona-ut Ode -or amine layers perlite, wood fiber, glass • - petite /isocyanurate composite, perlite/ . urethane. .�, 13O��m' �• to composite, phenolic, any composite, wood finer /isocyanura . po p Base Sheep Two or more layers Type Gam. or G3. Ply-Sheet (Optional):. One or mace layers Type. dl. • Membrane: One or morelayers "Ruberoid Torch" (Smooth or Granule), "Ruberoid Torch Plus' (granule), "Ruberoid Mop'.': (Smooth or Granule) or "Ruberoid Mop Plus" (granule), Sheer, hot mopped. Cap Sheet.. • "GAPGLAS Mtheral Cap Class B 1. Decic C -15/32 - Incline: 3-1/2 Insulation (Optional): One or more layers perlite, wood fiber, glass fiber, isocyanurate, • urethane, perlite/isocyanurate composite, perlite/ urethane composite, wood fiber /isocyanurate composite, phenolic, any thickness. PIy Sheet Two or more layer Type G1 "GAFGLAS PIy 4" or "GAP - GLAS Ply 6" Cap Sheet Type G3 "GAFGLAS Mineral Surfaced Cap Sheet ", hot mopped. 2. Deck: C -15/32 .-. - • Incline: 3-1/2 Insulation (Optional)): One or more layers Whitt "'pod fiber, glass fiber,- isocyairufate; urethane; potrhte /!lsocyanutak•Nktipasitt".• 5 ;• urethane. compositet-wood AberNiejaillurate gamest* P heriolic • •y thido • • ••• ••••• Base Sheet Two or more layers tyFre t1, G2 or G3� • Membrane: One or more layers•'R ddid Torch" (Smooth or rwtia� "Ruberoicl Torch Plus" (granule) (granule),iiBtdbVid Mop'• i?Sttioyth or dranule4 or 'Ruberoid Mop Plus" (granule }. • • • • • • • • :•: