MC-11-1532Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Inspection Number: INSP- 164851 Permit Number: MC -8 -11 -1532 Scheduled Inspection Date: September 28, 2011 Inspector: Perez, JanPierre Owner: BLANCHET, FRITZNER Job Address: 174 NW 100 Terrace Miami Shores, FL Project: <NONE> Contractor: MERCURY RISING HVAC INC Permit Type: Mechanical - Residential Inspection Type: Final Work Classification: New A/C System Phone Number Parcel Number 1131010230270 Phone: (239)348 -9927 Building Department Comments NEW A/C INSTALLATION 2 1/2 TON WITH NEW DUCT WORK coi Passed rr Failed Correction Needed Re- Inspection Fee No Additional Inspections can be scheduled until re- inspection fee is paid. Inspector Comments CREATED AS REINSPECTION FOR INSP- 163589. no one home jpp September 27, 2011 For Inspections please call: (305)762 -4949 Page 22 of 26 Project Address Miami Shores Village 10050 N.E. 2nd Avenue NW Miami Shores, FL 33138 -0000 Phone: (305)795 -2204 Parcel Number System V Expiration: 03/05/2012 Applicant 174 NW 100 Terrace Miami Shores, FL 1131010230270 Block: Lot: FRITZNER BLANCHET Owner Information Address Phone Cell FRITZNER BLANCHET 174 NW 100 TERR MIAMI SHORES FL 33150 -1210 Contractor(s) Phone Cell Phone MERCURY RISING HVAC INC (239)348 -9927 Valuation: Total Sq Feet: $ 3,000.00 0 Tons: 2 1/2 TON Additional Info: NEW A/C INSTALLATION Classification: Residential Approved: Yes Comments: NEW A/C CAN NOT BE LOCATED IN A REQI Date Approved: 9/2/2011 : Yes Date Denied: 8/22/2011 Type of Work: MECHANICAL Scanning: 1 Fees Due CCF DBPR Fee DCA Fee Education Surcharge Permit Fee Scanning Fee Technology Fee Total: Amount $1.80 $2.00 $2.00 $0.60 $105.00 $3.00 $2.40 $116.80 Pay Date Pay Type Invoice # MC -8 -11 -41797 09/07/2011 Check #: 699 $ 116.80 $ 0.00 Amt Paid Amt Due Available Inspections: Inspection Type: Final Rough Duct Underground In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL PLUMBING, MECHANICAL WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Futhermore, I authorize the above -named contractor to do the work stated. September 07, 2011 Authorized Signature: Owner / Applicant / Contractor / Agent Building Department Copy Date September 07, 2011 1 Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 INSPECTION'S PHONE NUMBER: (305) 762 4949 BUILDING PERMIT APPLICATION FBC 20 IF, Tam-m.3 al AUG 1 9 2019 ID Y: pennit J10 II—IS-57, Master Permit No. 6/I Permit Type: MECHANICAL j� ,�, OWNER: Name (Fee Simple: Titleholder): cc/ � ,/ c1 Address. City: /7q\ 404,J /00 -leYY State: 11 /1132 Phone #: zip: -33/ 3`a Tenant/Lessee Name: s n Phone #: Email: JOB ADDRESS- / / / //&J 49c 'k City: Folio/Parcel#: Miami Shores County: Miami Dade ez Zip: 3 3/ j-c) Is the Building Historically Designated: Yes NO Flood Zone: CONTRACTOR: Company Name: / 922eire'l./79 / e1 �'0�4hone #: e.3 [� 33© 2 Address. 3% 3 C e4C\nv:1' J(O6 4c/6-- City: /1/4 P 1t5 State: .'Ire ®c Zip: Qualifier Name: Refr71 A - Phone #: State Certification or Registration #: C/4 4 ( % kfi Certificate of Competency #: PAID q Contact Phone #: ? ( TX-/-376 V Email Address: G DESIGNER: Architect/Engineer: Value Work fonthistPermit ��J K osF spdv� f or I: aTfal reSSa -1914 01 ilCti ptibn of Wore r r5 00 ; g4 /, j teration Squar New w +: ea Phone #: 3o5 fit 1— 3 o 1 k i: } t Me i7< ga °rig, 4aB7etlalida; ° tasrb is C3D Cr t 2 '`3NEM et r I‘-e2 -ca& Lae olition **** x****** **************** * ****** *a ***F * *** * * * * ****** **** ** ********** * * *** ***** ** Submittal Fee $ Permit Fee $ tvso Scanning Fee $ Radon Fee $ Notary $ Training/Education Fee $ Double Fee $ Structural Review $ CCF $ CO /CC $ DBPR $ Bond $ Technology Fee $ TOTAL FEE NOW DUE $ (A\\.1. Bolting (ygmpany's Name (if applicable) fu Bonding Cd}npany's Address City State Zip Dig !tgagps N e (if applicable) k , Mortgage Lei der's )`,�i ss �', �. to k of • City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which curs sev z (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not 'e a nd a re.' ;, ection fee will be charged. Signa The foregg. day of ,./.4.1 if who is pers� ins ' ent was ac le % ged befo , 20JI,bY "u ' ally known to me or who has produced Mir take an oath. Contractor _,jl The foreg . ins ment was acknowl: : t bef • this day of , 20 %L , by (%, =.> who is pe 'nally known to me or who has produced NOTA Sign: Print: My Commission Expires: Sign: Print: My Commission Expires: *** *************a**** +six** ** ** . , *: ** ******** ** * * * ** * *** ******** ***** ** ***** ***** ** *********** *** 622" APPROVED BY Plans Examiner Structural Review (Revised 07 /10/07)(Revised 06 /10/2009)(Revised 3/15/09) ]ping Clerk Miami Shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 AIR CONDITIONING REPLACEMENT DATA PERMIT NUMBER: MC This form must accompany ALL air conditioning replacement permit applications. Each unit change -out must be on its own data sheet. Multiple units on single sheets are not acceptable. Job Address (where the work is being done): City: Miami Shores Village County: Miami Dade Zip Code: ALL CONDENSING UNITS MUST BE ON A 4 INCH SOLID CONCRETE SLAB ALL UNITS MUST COMPLY WITH F.E.M.A MINIMUM FLOOD ELEVATION A COPY OF THE CONTRACT IS REQUIRED WITH ALL SUBMITALS ARI (AHRI) DATA SHEET REQUIRED Change Disconnecting means: YES 0 NO ❑ ARHI Sheet Attached: YES ❑ NO ❑ Contract Attached: YES ❑ 1. Minimum Circuit Ampacity (Wire Size): 2. Maximum Overcurrent Protection (Fuse /Breaker Size): 3. Voltage of Circuit (208/240/480): 4. Size Disconnecting Means: Contractor's Company Name: Phone: State Certificate or Registration N. Certificate of Competency N. Signature (Qualifier's signature only) Date: UNIT BEING REPLACED DATA NEW UNIT MANUFACTURER 6,arese AHU or PKG. UNIT MODEL # /4' ATM 7.04o COND. UNIT MODEL # 44/0- KW HEAT t&Zl {1I_L /4,44 3 ® / 7--rAI NOM TONS AHU CU PKG 1) M.C.A AHU CU PKG AHU CU PKG 2) M.O.P AHU CU PKG AHU CU PKG 3) VOLTS AHU CU PKG PKG UNIT / / PKG UNIT / / EER/SEER YES " NO REPLACING DUCTS YES NO YES NO REPLACING THERMOSTAT YES NO YES NO NEW 4 "CONCRETE SLAB YES NO YES NO NEW ROOF STAND YES NO YES NO- NEW RETURN PLENUM BOX YES NO - 1. Minimum Circuit Ampacity (Wire Size): 2. Maximum Overcurrent Protection (Fuse /Breaker Size): 3. Voltage of Circuit (208/240/480): 4. Size Disconnecting Means: Contractor's Company Name: Phone: State Certificate or Registration N. Certificate of Competency N. Signature (Qualifier's signature only) Date: Planning and Zoning Criteria Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL 33138 -0000 Phone: (305)795 -2204 Fax: (305)756 -8972 Folio Number:1131010230270 Owner's Name: FRITZNER BLANCHET Job Address: 174 100 Terrace Miami Shores, FL Owner's Phone: Total Square Feet: Total Job Valuation: 0 $ 3,000.00 Contractor(s) Phone Primary Contractor MERCURY RISING HVAC INC (239)348 -9927 Yes I Planning and Zoning Criteria and Comments Tons: 2 1/2 TON Classification: Residential Additional Info: NEW NC INSTALLATION Approved: Yes 2011 -07 -01 13:02 » 9547971086 2011 -07- 0113:02 COLUER COUNTY BUSINESS TAX BUSINESS TAX NUMBER: 031335 COLLIER COUNTY TAX COLLECTOR - 2800 N. HORS&SHOE DRIVE - NAPLES FLORIDA 34104 - (239) 252 -2477 VISIT OUR WEBS AT: +ww wutartar lm THIS RECEIPT EXPIRES SEPTEMBER 30. 2011 LOCATION: 3983 EXCHANGE AVE UNIT C ZONED: INDUSTRIAL BUSINESS PHONE: 348 -9927 STATE LID: CAC1813888 I8.RP1 AY AT PLACE OF BUSINESS FOR PUBLIC INSPECTIOP FAILURE TO DO SO IS CONTRARY TO LOCAL LAWS. `• MERCURY RISING HEATING & AIR, INC. - THIS TAX IS NON - REFUNDABLE - i r "'`qk iPEREZ, RAFAEL A 3983 'EXCHANGE AVE UNIT C 0 NAPLES DER OF EMPLOYEES: 1-10 EMPLOYEES • q • .. ,t CLASSIFICATIONAIR CONDITIONING CONTRACTOR - CL14SB 1 CLASSIFICATION CODE 05100501 �' b� �,�. a""; This document is a business tax only. This Is not oerl icatlon that 0 f' II does not permit the Acensee to violate any existing regulatory zoning ar cities nor does It exempt the licensee iron► any other taxes or perm Its that may be i Atfil+ed'bWiBw.� FL 34104 DATE 09/1012110 AMOUNT 1100 RECEIPT 370142 Aug. 19. 2011 12:34PM Policy Number. 8090016214 No.2388 P. 1 Dale Entered: 9/20/2003 ACORl7® CERTIFICATE OF LIABILITY INSURANCE I GATE (MMIDDJWYY) 8/19/2011 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED t3Y THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER, AND THE CERTIFICATE HOLDER. - IMPORTANT: If the certificate holder Is an ADDITIONAL INSURED, the pollcy(les) must be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder In lieu of such endorsement(s). PRODUCER Parlin Insurance Agency PO Box 366697 Bonita Springs, FL 34136 24520 Production Cr., #4 Bonita Springs, FL 34135 CONTACT NAME: PAX PAM P,,,), (239)263 -37.41 (iA1c,No1; (239)263 -8696 WC.N ADDRESS! INSURER(a) AF'FORDINO COVERAGE NA(C 0 INSURERAINORTREOTNTE INS. CO. LIABILITY coMMERC1ALOENEwu LwelLtllY INSURED MERCURY RISING UAVC INC RALPH PEREZ 3963"C EXCHANGE AVE . NAPLES, FL 34104 INSURER R: 8090016219 INSURER CI )4/14/2012 INSURER D I $500,000 ►URERE: x100,000 INSURER F r CLAWIS-MADEr OCCUR COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN. THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS. EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. WSR LTIA TYPE OP INSURANCE AWL INSR SUM CND POUCYNUMBER `POLICY EPP IMMU)DIYYYY), POLICY EIIP MMmIIYYYY) Loam A GENERAL LIABILITY coMMERC1ALOENEwu LwelLtllY 8090016219 04!14 /20X1 )4/14/2012 EACH OCCURRENCE $500,000 DAAApi1AAG RENTED PREMISESfEaocciYretwei x100,000 CLAWIS-MADEr OCCUR MED EXP (Anyone person) $5,000 LIMITS AS OF PERSONAL &ADVIMJURY $500,000 INCEPTION DATE GENERAL AGEIREGATE 31,000,000 G/EH�L AGGREGATE LIMITAPP�—LIES7PE[C XI POLICY El f<:T I I LOC PRODUCTS- CCM?/OPAOO $1,000,000 $ AUTOMOBILE — — _ LIABILITY ANYAUTO ALL OWNED AUTOS HIRED AUTOS _ — SCHEDULED AUTOS AmosPine COMBINED SINGLE LQAR (Ea acmdart) $ BODILY INJURY(Per person) $ NODILYINJURY(Perscodsny 1 $ $ UMBRELLA L)A$ EXCESS LIAR OCCUR ci. ws-MADE EACH OCCURRENCE $ AGGREGATE I 0E0 I I RETENTIONS 1 WORKERS COMPENSATION AND EMP60Yali5' LIABILITY YIN ANYPROPRIETORIPARTNER�(ECUrIVE OFFICERIMEMBEREXCWDED7 ❑ IMyiBeon Glory in NH) DESCRIPTION OF OPERATIONSbe»,, N/A I WC STI ATU- I 10TN- TORY ITS FR EL.. EACH ACCIDENT 1 el_ DISEASE -EA EMPLOYEE $ EL DISEASE - POLICY UNIT $ DESCRIPTION OP OPERATIONS I LOCATIONS I VERIOI.R$ (AMaoh ACORD 101, Additional Romania eoeaauto. II moos spans Is.quLed) HEAVING & AC INSTALLATION AND SERVICE ( CERTIFICATE HOLDER C MIAMI SHORES VILLAGE 10050 NE 2ND AVE. SHOULD AN OF . E ADO ' THE EXPIRA ON > TE 0 SCRUM') POLICIES BE OANOELLED BEFORE F. NOTICE WILL BE DELIVERED IN MIAMI SHORES, FL 337.39 ACCT D POL `/ _.S. VAX: 305 - 7568972 AUTHORIZED REPrR ` ` DERMA WILL ti `11r ACORD 26 (2010105) The ACORD name and logo are registered m Produced using Forma Ross Phis software. www.FormaSeas.00m; lmpreestie PuDDSN lg 800-208 -1977 ®1988.10 A� CORD Cd bRATION. All rights reserved. arks of ACORb 2011 -07- 0113:03 >> 9547971086 JEFF ATWATER CHIEF FINANCIALOFFICER DEPARTMENT OF FINANCIAL DIVISION OF WORKERS' COMP * * CERTIFICATE OF ELECTION TO BE EXEMPT FROM FLORIDA CONSTRUCTION INDUSTRY EXEMPTION This certifies that the individual listed below has elected to be exempt from EFFECTIVE DATE: 05/25/2011 PERSON: PEREZ FEIN; 272207013 BUSINESS NAME AND ADDRESS; MERCURY RISING HVAC INC 3983 —C EXCHANGE AVE NAPLES FL 34104 -3737 EXPIRATION DATE: 05 RAFAEL A SCOPES OF BUSINESS OR TRADE 1- HVAC CONTRACTOR 2- CERTIFIED AC CONTRACTOR IMPORTANT: Perserot to ehaptar 440 . 061141, F.L. an altica of a corporation who Mule eitamptino from II aeatten may not recover heniffid Or comminution ceder this chsytsr. Pursuant In Chapter 40.061121, f,5., Cord scope of the bueteeaO Of WO* lifted an the notice of elaetion to hi eaamp4 Puruset to Chapter 440.051151, election to he eseetpt men be subject to revotmtios If, Nagy lime after lba filing of the mice or the form certificate no longer mess the requirements of this sestina for Masse, at a centllcste. The eepaiiato that owed an the certificate to meet the requireateate of tiiis sullen. DWC -252 CERTIFICATE OF ELECTION TO BE EXEMPT REVISED 01 -11 P 414 05 -26 -2011 RVICES SATION NORK*RR' COMPENSATION LAW * * Florida Workers' Compensation law. 25/2013 s chapter by riling a certificate of alealoa and■r this testes a election to be exempt... apply only within the 5., Naxos of mouton to be exempt and ceniilHtee of tee of tee unlike*, the paean named an the notice or revoke s cenrilcete M any time for lallere 01 the pwrso9 OuESTIoNS? (850) 413- 9547971086 2011 -07 -01 13:02 e u tai #14'c 3 C3 - c EKcI -1 /wc 64A_ 4-16' ye--5 �. 3 f t O tf -_ -cl( 7 08/19/11 04:21P11 SOUTH UNITED APPLIANCE 305 - 823 -1081 p.01 —tau ■ % CERT EIEDT wow a ititfireeiory.bfq r. This combination qualifies for a Federal Energy Efficiency Tax Credit when placed In service between Feb 17, 2009 and Dec 31, 2011. Certificate of Product Ratings AHRI Certified Reference Number: 3805937 Date: 8/19/2011 Product: Split System: Air - Cooled Condensing Unit, Coil with Blower Outdoor Unit Model Number: 14AJM30 Indoor Unit Model Number: RHLL- HM3821 +RCSL -H *3821 Manufacturer: RHEEM MANUFACTURING COMPANY Trade /Brand name: RHEEM 14AJM SERIES Manufacturer ressponsible for the rating of this system combination is RHEEM MANUFACTURING COMPANY Rated as follows in accordance with AHRI Standard 210/240.2008 for Unitary Air-Conditioning and Air - Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI- sponsored, independent, third party testing: Cooling Capacity (Stub): 29600 EER Rating (Cooling): 13.00 SEER Rating (Cooling): 16 :00 • • • • 41' • Ratings followed by an asterisk (•) indicate a uolun1ary rcrate of previously published dale, unless accompanied with a WAS, which indicates en Involuntary mete. DiSCLAIMER AHRI does not endorse the productia) listed on this Certificate and makes no reprosontatlons, warranties or guarantees as to, and assumes no seapansibitisy for, the product(e) listed on this Certificate. AHRI expressly disclaims ail liability for damedes of any kind arising out of the use or perl'amtanoe of the pro(ae 0), or the unauthorized alteration of dais listed on this Certificate. Certified ratings are valid only for models and configurations listed In the directory at www.ehritlifeotory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRt. This certificate shell only be used for Individual. personal end confidential ruference purpenes. The contents of this Certificate may not, In whole or in part, be reproduced; copied: disseminated; entered into a computer database; or otherwise utilized. In any form or manner or by any means, except for the user's individual, personal and confidential tolerance. CERTIFICATE VERIFICATION The Information for the model cited Om this certificate can be Verified at www.ahridiroctory.orp, Air - Conditioning, Hooting, elicit on `Verify Certificates link and enter the AHI I Certified Reference Number and the date on 111* *1 and Refrigeration institute which the certificate was issued, which is listed above, and the Certificate No„ which Is listed below. ©2011 Air - Conditioning, Heating, and Refrigeration institute CERTIFICATE NO.: 129582568449030000 I i Planning and Zoning Criteria Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL 33138 -0000 Phone: (305)795 -2204 Fax: (305)756 -8972 Permit NO. M C -8 -11 -1532 Expires: Not Issued Folio Number:1131010230270 Owner's Name: FRITZNER BLANCHET Job Address: 174 100 Terrace Miami Shores, FL Owner's Phone: Total Square Feet: 0 Total Job Valuation: $ 3,000.00 Contractor(s) MERCURY RISING HVAC INC Phone (239)348 -9927 Primary Contractor Yes i Planning and Zoning Criteria and Comments Tons: 2 1/2 TON Classification: Residential Additional Info: NEW A/C INSTALLATION Approved: No Neu 4/c � � (c. l c_ -(= d ;, s J 5 (A,- e7 9 2011-08-22 08:07 LICENSED & INSURED CAC1813688 • URY RISING I-NAC » 1 800 685 7530 P 1/1 DATE 8/14/2011 3963 — eexchange ave Naples Flozsda,34104 Phone: (786) 374 -3064 O.ffice/Fax(305) 280-1222 FAPAC Service I Repairs - 24 Roue Emergency Service • Building Services • Consulting Services • Team Design Protect Management • Preventive Maintenance • Programs • Energy Mews .ystems Refrigeration Computer Cmitng System • Value Engineering - Design & BuI1d Projects Blanchett Frltzner & W d mite 174 nw 700 ter:. BILL TO — ADDRESS WORKDONE AT ADDRESS CITY REM. CALL NIOlirCA11 SATURDAY.•- --w.�� SUNA{OLIDAY PHONE ND. LAS MIT/ALT INSTALJAT(ON TILE It MAT Install 2.5 ton a/c with heat and duct work as per plan . NC to be 16.0 seer Rheem a/c m. vents to be R6 and heater a 7.5 kw .units have a 10 year warranty on compressor 5 year on coma parts and 1 year on labor. �• COD. � COMPLETED INCOMPLETED -- - ELIWTRICAL — OUCIWORIC PART NO. DESCRIPTION Description Deposit required to start of 1000.00 balance upon completion 2000.00 thanks, Lorenzo. — TECHNICIAN nttylcE MATERIAL, RCS. CLEANERS, MISC. LUBRICANTS, ETC. r ss sT RaaOHr AIATERIAL DATE START FINISH TITHE O.T. HOURS TOTAL FIELD LABOR OWNERS ACKNOWLEDGMENT TOTAL BILL 1 3000.00 Miami Shores Village Building Department RECEIPT PERMIT #: frISMDATE: I, NContractor ❑ Owner ❑ Archite 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 Ad .r From the building department on this date in order to have corrections done to plans And /or get County stamps. I nderstand that the plans need to be brought back to Miami Shores Village Building D p rtment to continue per fitting process. Acknowledged by: PERMIT CLERK INITIAL: vidaa-qcei RESUBMITTED DATE: I PERMIT CLERK INITIAL: tAk, Miami Shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 Permit No. 14 — 2./* . Job Name CRITIQUE SHEET r 4 'AVILA 000 /alas .' stoke 00. W. all = . SU 201 HIALEAH. FL 33012 PHONE :005)8123710 BOUNDARY SURVEY PAGE 1 OF 2 NOT VAID WITHOUT PACE_ 2 OF 2 JOB No. 1 1- 0818608 Drawn by: e NW 2ND AVENUE NW 100TH TERRACE K-IEMALOT T OF LoT � 1 REMAINDER OF LOT 2 9 &POF DTS 1, LOT 10 LOT 11 LOT 1 OF LOT 3 REMAINDER OF LOT 4 LOT 5 LOT 6 LOT 16 LOT 15 LOT 14 LOT 1 LOT 7 LOT 8 NW 100TH STREET 3 JOB No. 11-0818608 CLIENT: FRITZNER BLANCHET & W MERITA PROPERTY ADDRESS 174 NW 100TH TERRACE, MIAMI SHORES FL 33150 LEGAL DESCRIPTION: (FURNISHED BY CLIENT) LOT 9 AND EAST 25.0 FEET OF LOT 1, 2. 3 & 4, BLOCK 4 SUBDIVISION MAP OF BONMAR PARK ADDITION A RESUBDIVISION OF AKRON ACCORDING TO THE PLAT THEREOF AS RECORDED IN PLAT BOOK _ 24 _ AT PAGE _» OF THE PUBLIC RECORDS OF MIAMI -DADE COUNTY, FLORIDA. SUBJECT TO ALL RESTRICTIONS, RESERVATIONS, EASEMENTS AND RIGHT -OF -WAY OF RECORD, UNDERGROUND ENCROACHMENTS IF ANY, NOT LOCATED. LEGAL NOTES THE SURVEY OF THE PROPERTY SHOWN HEREON IS IN ACCORDANCE WITH THE DESCRIPTION FURNISHED BY CUENT NO SEARCH OR PUBLIC RECORDS HAS BEEN MADE BY THIS OFFICE FOR ACCURACYNGVD DATUM 1929 OR OMISSIONS. SUBJECT TO OPINION TITLE. I HEREBY CERTIFY: THAT THE ATTACHED BOUNDARY SURVEY OF THE ABOVE DESCRIBED PROPERTY IS TO THE BEST OF MY KNOWLEDGE AND BELIEF AS RECENTLY SURVEYED PLATTED UNDER MY DIRECTION; ALSO THAT THERE ARE NO ABOVE GROUND ENCROACHMENTS OTHER THAN THOSE SHOWN, AND THAT THIS SURVEY MEETS THE MINIMUM TECHNICAL STANDARDS SET BY THE FLORIDA BOARD OF LAND SURVEYORS AS SET FORTH IN 472.027 (F.5) AND CHAPTER 5J -17 F.A.C. (FLORIDA ADMINISTRATIVE CODE). ELEVATIONS REFER TO: NGVO DATUM 1929 B.M. USED NN-567 _ ELEVATIONS 10.54 FEET B.M. LOCATED ME 104TH STREET N Mi nGERu anagtlittECOMBen BASED ON THE FLOOD INSURANCE RATE MAP OF THE FEDERAL EMERGENCY MANAGEMENT AGENCY DATED OR REVISED ON 9.9..412.09 THE HEREIN DESCRIBED PROPERTY IS SITUATED WITHIN ZONE _ X __ BASE FLOOD ELEVATION MLA__ COMMUNITY 120652 PANEL NUMBER - 0302 SUFFIX SURVEYOR NOTE: BEFORE ANY CONSTRUCTION THE SET BACKS MUST BE CHECKED THE CERTIFICATE DOES NOT ExTEND TO ANY UNNAMED PARTY. G'BM[FELI TO' FRITZNER BLANCHET & W MERITA SURVEY DATE: 08/26/11 `>t1 'AVILA 1 �p 7'soclates Services, Inc. an CERTIFICATE OF AUTHORIZATION NO. 29058 CERTIFICATE OF AUTHORIZATION NO. 7E38 1800 W. 49th ST. SUITE 201 HIALEAH, FL 33012 PHONE:(305) 512 -3710 9Y. EFRAIN C. LOPEZ, P.L.S. CERTIFICATE No.LS. -2300 STATE OF FLORIDA •NOT VALID WITHOUT THE SIGNATURE. DATE AND THE ORIGINAL RAISED SEAL OF A FLORIDA LICENSED SURVEYOR AND MAPPER. ( e N f>T1 '''+ ,1 PACE 2 OF 2 till= 'siig�n'AV I LA NOT TutO NTMOJT PAGE , 0F 2 wir/ales &Mees Inc 1800 W. 48UI BT. 201 JOB No. `L BOUNDARY SURVEY o>aIIY, i1- 0818608 NINE30PL33812 PNONE:(3D81813.3710 �'� SCALE: 1" = 0' »' ao l 011 '100TH TERRACE::.' ::::160 ASPH. PVA4T.... ;::':::•.. .' :': ............. inr‘r i 7500' ;•ASPHALT ; N '4' .' 75.00' R &M): :: •. :: '..... 89....... 49.T ..... :::. . :: ; .. ... ...... .. .. 17.0' PARKWAY F.IPa CORNER BLOCK F.I.P 31"11- W Z REMAINDER OF LOT 1 W BLOCK 4 Q Cl PORTION OF 91 0� LOT1 41.1 ' BLOCK 4 8.0 , • ;Y • h .• .y CONC. I • I �� 1/ I Ti 23.0' `o� P. • ' N ,j �o � A°j ,/ 21 R. /�8 S. ail LOT 10 BLOCK 4 'Cf o 13.80' 0 1c 0, LOT 9 r..1LOCK 4 1/ 22.3' Z CV �.8� 10.0' ^ • , - 0 +p 9p . in °ryo . 8.b., O 18.50' Z REMAINDER OF LOT 2 0.2'CL 3A u. 10.70' nj I ONE STORY /\::(:) 3' RES # 174 . I F.F. ELEV. 13.22 ,yr�L��)'j N BLOCK 4 x ad I re x a 6 N O $ O W P�� I 9.8' 19.50' I o " ' x ./ o v . o'Y 7.0. p b `° 23.50. N. TT` 2A x 22.3.x ___1 O.J'CI� '8 I \ / ��(�+p �CI LL Ol z ,% l \� I 8 \� `1\c > REkI�TdDEi $F 4' CLF \w�L'"'OT t (<, BLCO4 dos o -I u. v d ° \ M x 0 13 I, v. I z .L �N G. x �� ON O �/ in \ ) x \�3 —xIP� �- 4' CLF 0.25'0. 0 N-.., ( %—t —Y —Y I Y— Y-- K�I( F.IP3I C` O / 1, l + N.. LOT 5 C". BLOCK 4 /: . % 75.00' (R &M) P:P. / /�It✓✓✓ 4• CLF J in Q LOT 18 BLOCK 4 LOT 14 BLOCK 4 iggligLAKIABBEMENe U'. METAL FENCE —°' ��p PA ,P9 ELEVATION C. R G. cum b CUTTER P.R.0 OREM MEOW SLR. SET IRON ROD P.C. V.P. UTILITY POLE P.0.G POINT CF COMMEN- CEMENT F.NA. D.O.E. BASIS or BEARINGS F.N. FOUND MALL P.T. POINT OF TANGENCY P.C.C. AC AIR CONpITNONIN6 PAO )LT A ARC DISTANCE E.N.C. ENMCALNMENT N. OVA. SLOG. BUILDING FR. FINE HYDRANT CB. CATCH WSW FLT. POUNA EON PPE O.E. MS. CONCRETE BLOCK STRUCTURE FUR. MIND REBAR P.B. D.E. . DRAINAGE EASEMENT oz. LansT FLOOR ELEVATION P.C.P. P.G. CL. CLEAR LP. LIGHT POLE P.09. F CENTER Lau Ni MEASURED R E.D.W. CONC. CONCRETE (TT) RECORD EDGE Of WATER (R & Al) RECORD & MEAD N.T.S. uC,- '' 0. a u. E. PONT CA NTEBSECTION PONT OF REVERSE CURVE L Y. E. PORT OF CURVATURE —fi..— FOND NAIL/OI5K —%— POINT OF COMPOUND CURVE ® MONUMENT UNE B/C R D & UNAENASCE LUTE MAINTENANCE EASEMENT ROOD FENCE (a• NATO CAN NM FENCE (4' •_ d.9S. IYALL SO BLOCK CORNER RADIUS RMUL RESIDE/RI SAW OF we sEGTxxN SET WON PIPE STORY SbLITY EASEMENT UTILITY EASEMENT NIOIONAL GEODETIC VERTICAL DATUM RIID. PEAT BOOK ELECTRC LINE NCR. PLAT BOOK PERMANENT CONTm PONT SEC. PAGE PONT OF BEGINNING SIP. PROPERTY LNE STY NOT TO SCALE SOX CENTRa. ANGLE UL To whom it may concern: PROPOSAL FOR: M.R. AND RAFAEL PEREZ 174 NW.100 TERRACE MIAMI SHORES, FL. 8/10/2011 Prepared 8/10/2011 using O'Brien Quick Loads Pro - Version 1.01 - SN: XX X)0000( XXXXX To whom it may concern: Heat Load Summary Report for M.R. AND RAFAEL PEREZ Room Square Heating Loss Hydronic Heat Latent / Sensible Cooling Gain Cooling Cooling Name Ft. BTUH Linear Ft. Gain BTUH BTUH Tons CFM LIVING RM. 310 - 123353 - 246.71 2369 / 7171 9539 0.79 258 KITCHEN 137.5 -56035 - 112.07 669 / 3420 4089 0.34 110 DINING RM. 112.5 -45914 -91.83 252 / 1714 1965 0.16 44 FLORIDA RM. 220 -89213 - 178.43 492 / 7089 7581 0.63 210 BED RM. #2 138 0 0 0 / 0 0 0. 0 BATH RM. 42.5 0 0 0 / 0 0 0. 0 BED RM. #1 138 -55935 - 111.87 709 / 4351 5059 0.42 142 HALL 17.5 -7142 -14.28 39 / 1213 1252 0.1 42 TOTALS 1116 - 377592 - 755.18 4530 / 24958 29488 246 806 Disclaimer These computed results should be treated as estimates only and should be viewed as only one of the many tools required for a professional installation. The installing contractor's experience and expert judgement are also major factors in sizing and installing a complete system. The weather, customer usage, duct installation, and structure design may vary on each estimate and should be taken into account. Correct system sizing is based on the systems ability to meet both latent and sensible heat requirements, not Just total BTUs. Prepared 8/10/2011 using O'Brien Quick Loads Pro - Version 1.01 - SN: XX- )00000C- X)0000 To whom it may concern: Heat Load Detail Report for M.R. AND RAF'AEL PEREZ Room 1 of 8 Room Specifications: LIVING RM. 5 Sq. Ft windows facing NE & NW: — Sq. Ft windows facing South: — Sq. Ft windows facing SE & SW: — Number of Exterior Doors: 1 Sq. Ft Exterior Doors: 24 Number of People in Room: — Room Length (Ft.) : 15. Room Width (Ft) : 20 Room Height (Ft) : 8 Exposed Wall Length (Ft) : 36 Wall against unconditioned room (Ft.) :- Sq. Ft windows facing North: 48 Sq. Ft windows facing E & W: 12 Summer. inside (Thermostat setting) : Outside (Above ground): outside (below ground): Unconditioned Space : Above Ceiling (Attic/Crawl Space) : Concrete Slab (Ground temperature) : Unconditioned Basement : Below Floor Crawl Space : Watts Incandescent Light 300 Watts Flourescent Light Duct Length from A/H to room: Number of Large Electric Motors: Average Electric Motor Horsepower. BTUH Appliance Sensible Heat: BTUH Appliance Latent Heat Indoor /Outdoor Design Temperatures (degrees Farenheit) Winter 75 Inside (Thermostat setting) : 90 Outside (Above ground : 80 Outside (below ground) : 87 Unconditioned Space : 100 Above Ceiling (Attic/Crawl Space) : 77 Concrete Slab (Ground temperature) : 80 Unconditioned Basement : 86 Below Floor Crawl Space : 58 47 90 55 49 46 48 5046 Applicable Temperatures: Above Ceiling: Attic or Crawl Space Below Floor. Crawl Space Exposed Walls: Above Ground Design Conditions Occupant Sensible Load (BTUH per person) : 250 Occupant Latent Load (BTUH per person) : 200 Duct Insulation Factor : 1 Duct Temperature Difference (Summer) : 30 Duct Temperature Difference (Winter) : 25 Humidity Difference Inside/Outside % (Summer) : 50 Humidity Difference inside/Outside %(Winter) : 56 Fresh Air Per Person (CFM) : 2 Air Change Factor (Air change per hour) : .5 Space Shading Factor : .6 Air Handler Design Cooling (CFM per ton) : 400 Hydronic Heat (BTUH per linear ft : 500 Calculated Room Results - Wall Heat Gain (BTUH) : 346 Ceiling or Roof Heat Gain (BTUH) : 2224 Floor Heat Gain (BTUH) : 283 Glass Heat Gain (BTUH) : 148 Exterior Door & North Window Heat Gain (BTUH) : 454 Solar Heat Gain (BTUH) : 1548 Total Transmission Heat Gain (BTUH) : 5002 Calculated Room Results Transmission Heat Losses (BTUH) : - 126846 Sensible Ventilation Heat Losses (BTUH) : 840 Insulation Values (U- Factors) Exposed Walls (Above Ground) : Exposed Walls (Below Ground) : Partitions : Roof/Ceiling : Floor (Above basement) : Floor (Concrete slab) : Floor (Between conditioned spaces) : Doors : Windows : .080 .5 .075 0.287 .083 .001 .287 .500 .900 Summer Heat Gains Appliance/Else Motor Latent Heat Gain (BTUH) : 0 Appliance/Elec Motor Sensible Heat Gain (BTUH) :1023 Ventilation Latent Heat Gain (BTUH) : 2369 Ventilation Sensible Gain (BTUH) : 1145 Summer Total Latent Heat Gain: 2369 Summer Total Sensible Heat Gain (BTUH) : 7171 TOTAL SUMMER COOLING LOAD (BTUH) : 9539 - Winter Heat Losses Latent Ventilation Heat Losses (BTUH) : Hydronic Heat(Linear Ft.) : 2653 -247 TOTAL WINTER HEATING LOAD (BTUH) : - 123353 Calculated Totals for Entire Structure Size of Structure (Sq. Ft.): 1116 Total Sensible Heat Gain (BTUH): Total Heat Loss (BTUH): - 377592 Total Cooling Gain (BTUH): Total Hydronic Heat (Linear Ft): - 755.18 Total Cooling Requirement (Tons): Total Latent Heat Gain (BTUH): 4530 Total Cooling CFM: 24958 29486 2.46 806 Disclaimer These computed results should be treated as estimates only and should be viewed as only one of the many tools required for a professional installation. The installing contractor's experience and expert judgement are also major factors in sizing and installing a complete system. The weather, customer usage, duct installation, and structure design may vary on each estimate and should be taken into account. Correct system sizing is based on the systems ability to meet both latent and sensible heat requirements, not just total BTUs. Prepared 8/10/2011 using O'Brien Quick Loads Pro - Version 1.01- SN: )OC- XXXXXX X)000( To whom it may concern: Heat Load Detail Report for M.R. AND RAFAEL PEREZ Room 2 of 8 Room Specifications: KITCHEN Sq. Ft windows facing NE & NW: — Sq. Ft windows facing South: — Sq. Ft windows facing SE & SW: — Number of Exterior Doors: — Sq. Ft. Exterior Doors: Number of People in Room: Room Length (Ft.) : 12.5 Room Width (Ft.) : 11 Room Height (Ft.) : 7 Exposed Wail Length (Ft.) : 22.5 Wall against unconditioned room (Ft.) :- Sq. Ft windows facing North: Sq. Ft windows facing E & W: — Summer. Inside (Thermostat setting) : Outside (Above ground): Outside (iielow ground): Unconditioned Space : Above Ceiling (Attic/Crawl Space) : Concrete Slab (Ground temperature) : Unconditioned Basement : Below Floor Crawl Space : Watts Incandescent Light — Watts Flourescent Light 80 Duct Length from A/H to room: — Number of Large Electric Motors: 1 Average Electric is Motor Horsepower. .250 BTUH Appliance Sensible Heat 800 BTUH Appliance Latent Heat 400 Indoor /Outdoor Design Temperatures (degrees Farenhelt) Winter: 75 Inside (Thermostat setting) : 90 Outside (Above ground : e0 Outside (Ueiow ground) : 87 Unconditioned Space : 100 Above Ceiling ( Attic/Crawl Space) : 77 / Concrete Slab (Ground temperature) : 80 ( Unconditioned Basement : 86 Below Floor Crawl Space : 58 47 5ti 55 49 46 48 5046 Applicable Temperatures: Above Ceiling: Attic or Crawl Space Below Floor. Crawl Space Exposed Walls: Above Ground Design Conditions Occupant Sensible Load (BTUH per person) : 250 Occupant Latent Load (BTUH per person) : 200 Duct Insulation Factor : 1 Duct Temperature Difference (Summer) : 30 Duct Temperature Difference (Winter) : 25 Humidity Difference Inside/Outside % (Summer) : 50 Humidity Difference Inside/Outside %(Winter) : 56 Fresh Air Per Person (CFM) : 2 Air Change Factor (Air change per hour) : .5 Space Shading Factor : Air Handier Design Cooling (CFM per ton) : Hydronic Heat (BTUH per linear ft : .6 400 500 Calculated Room Results - Wall Heat Gain (BTUH) : 189 Ceiling or Roof Heat Gain (BTUH) : 987 Floor Heat Gain (BTUH) : 126 Glass Heat Gain (BTUH) : 0 Exterior Door & North Window Heat Gain (BTUH) : 0 Solar Heat Gain (BTUH) : 0 Total Transmission Heat Gain (BTUH) : 1301 Calculated Room Results Transmission Heat Losses (BTUH) : -56432 Sensible Ventilation Heat Losses (BTUH) : 95 Insulation Values (U- Factors) Exposed Walls (Above Ground) : Exposed Walls (Below Ground) : Partitions: Roof/Ceiling : Floor (Above basement) : Floor (Concrete stab) : Floor (Between conditioned space) : Doors : Windows: .080 -5 .075 0.287 .083 .001 .287 .500 .900 Summer Heat Gains Appllance/Etec Motor Latent Heat Gain (BTUH) : 400 Appliance/Elec Motor Sensible Heat Gain (BTUH) :1988 Ventilation Latent Heat Gain (BTUH) : 269 Ventilation Sensible Gain (BTUH) : 130 Summer Total Latent Heat Gain: 669 Summer Total Sensible Heat Gain (BTUH) : 3420 TOTAL SUMMER COOLING LOAD (BTUH).: 4089 - Winter Heat Losses Latent Ventilation Heat Losses (BTUH) : 302 Hydronic Heat(Linear Ft.) : -112 TOTAL WINTER HEATING LOAD (BTUH) : -58035 Calculated Totals for Entire Structure Size of Structure (Sq. Ft.): 1116 Total Sensible Heat Gain (BTUH): Total Heat Loss (BTUH): - 377592 Total Cooling Gain (BTUH): Total Hydronic Heat (Linear Ft.): - 755.18 Total Cooling Requirement (Tons): Total Latent Heat Gain (BTUH): 4530 Total Cooling CFM: 24958 29486 2.46 806 Disclaimer These computed results should be treated as estimates only and should be viewed as only one of the many toots required for a professional installation. The installing contractor's experience and expert judgement are also major factors in sizing and installing a complete system. The weather, customer usage, duct installation, and structure design may vary on each estimate and should be taken into account. Correct system sizing is based on the systems ability to meet both latent and sensible heat requirements, not just total BTUs. Prepared 8/10/2011 using O'Brien Quids Loads Pro - Version 1.01 - SN: )O()0000CX)0000C To whom it may concern: Heat Load Detail Report for M.R. AND RAFAEL PEREZ Room 3 of 8 Room Specifications: DINING RM. 12.5 Sq. Ft windows facing NE & NW: — 9 Sq. Ft windows facing South: - 8 Sq. Ft windows facing SE & SW: — Number of Exterior Doors: — Sq. Ft. Exterior Doors: Number of People in Room: Room Length (Ft) : Room Width (Ft) : Room Height (Ft) : Exposed Wall Length (Ft.) : Wall against unconditioned room (Ft) :- Sq. Ft windows facing North: — Sq. Ft windows facing E & W: — Watts Incandescent Light 200 Watts Flourescent Light Duct Length from A/H to room: Number of Large Electric Motors: — Average Electric Motor Horsepower. — BTUH Appliance Sensible Heat — BTUH Appliance Latent Heat: — indoor /Outdoor Design Temperatures (degrees Farenheit) Winter. 75 inside (Thermostat setting) : 90 Outside (Above ground : 80 Outside (iietow ground) : 87 Unconditioned Space : 100 Above Ceiling (Attic/Crawl Space) : 77 Concrete Slab (Ground temperature) : 80 Unconditioned Basement : 86 Below Floor Crawl Space : Summer: Inside (Thermostat setting) : Outside (Above ground): Outside (Below ground): Unconditioned Space : Above Ceiling (Attic/Crawl Space) : Concrete Slab (Ground temperature) : Unconditioned Basement : Below Floor Crawl Space : 58 47 5U 55 49 46 48 5046 Applicable Temperatures: Above Ceiling: Attic or Crawl Space Below Floor. Crawl Space Exposed Walls: Above Ground Design Conditions Occupant Sensible Load (BTUH per person) : 250 Occupant Latent Load (BTUH per person) : 200 Duct Insulation Factor : 1 Duct Temperature Difference (Summer) : 30 Duct Temperature Difference (Winter) : 25 Humidity Difference Inside/Outside % (Summer) : 50 Humidity Difference Inside/Outside %(Winter) : 56 Fresh Air Per Person (CFM) : 2 Air Change Factor (Air change per hour) : .5 Space Shading Factor : .6 Air Handler Design Cooling (CFM per ton) : 400 Hydronic Heat (BTUH per linear ft : 500 Calculated Room Results - Wail Heat Gain (BTUH) : 0 Ceiling or Roof Heat Gain (BTUH) : 807 Floor Heat Gain (BTUH) : 103 Glass Heat Gain (BTUH) : 0 Exterior Door & North Window Heat Gain (BTUH) : 0 Solar Heat Gain (BTUH) : 0 Total Transmission Heat Gain (BTUH) : 910 Calculated Room Results Transmission Heat Losses (BTUH) : -46285 Sensible Ventilation Heat Losses (BTUH) : 89 Insulation Values (U- Factors) Exposed Walls (Above Ground) : Exposed Walls (Below Ground) : Partitions : Roof/Cei ing : Floor (Above basement) : Floor (Concrete slab) : Floor (Between conditioned spaces) : Doors : Windows: .080 .5 .075 0.287 .083 .001 .287 .500 .900 Summer Heat Gains Appfiance/Etec Motor Latent Heat Gain (BTUH) : 0 Appliance/Elec Motor Sensible Heat Gain (BTUH) :682 Ventilation Latent Heat Gain (BTUH) : 252 Ventilation Sensible Gain (BTUH) : 122 Summer Total Latent Heat Gain: 252 Summer Total Sensible Heat Gain (BTUH) : 1714 TOTAL SUMMER COOLING LOAD (BTUH) : 1965 - Winter Heat Losses Latent Ventilation Heat Losses (BTUH) : Hydronic Heat(Linear Ft) : 282 -92 TOTAL WINTER HEATING LOAD (BTUH) : -45914 Calculated Totals for Entire Structure Size of Structure (Sq. Ft.): 1116 Total Sensible Heat Gain (BTUH): Total Heat Loss (BTUH): - 377592 Total Cooling Gain (BTUH): Total Hydronic Heat (Linear Ft.): - 755.18 Total Cooling Requirement (Tons): Total Latent Heat Gain (BTUH): 4530 Total Cooling CFM: 24958 29486 2A6 806 Disclaimer These computed results should be treated as estimates only and should be viewed as only one of the many tools required for a professional installation. The installing contractor's experience and expert judgement are also major factors in sizing and installing a complete system. The weather, customer usage, duct installation, and structure design may vary on each estimate and should be taken into account Correct system sizing is based on the systems ability to meet both latent and sensible heat requirements, not Just total BTUs. Prepared 8/10/2011 using O'Brien Quick Loads Pro - Version 1.01 - SN: XX- XX)000 -XXXX ( To whom it may concern: Heat Load Detail Report for M.R. AND RAFAEL PEREZ Room 4 of 8 Room Specifications: FLORIDA RM. Room Length (Ft.) : 10 Sq. Ft windows facing NE & NW: — Room Width (Ft.) : 22 Sq. Ft windows facing South: Sq. Ft windows facing SE & SW: Number of Exterior Doors: Sq. Ft. Exterior Doors: Number of People in Room: Room Height (Ft.) : 8 Exposed Wall Length (Ft.) : 23.5 Wall against unconditioned room (Ft.) :- Sq. Ft windows facing North: Sq. Ft windows facing E & W: 24 IndoorlOutdoor Summer. Inside (Thermostat setting) : Outside (Above ground): Outside (below ground): Unconditioned Space : Above Ceiling (Attic/Crawl Space) : Concrete Slab (Ground temperature) : Unconditioned Basement : Below Floor Crawl Space : Watts Incandescent Light 350 12 Watts Flourescent Light Duct Length from A/H to room: Number of Large Electric Motors: — 18 Average Electric Motor Horsepower. — BTUH Appliance Sensible Heat: — BTUH Appliance Latent Heat — Design Temperatures (degrees Farenheit) Winter. 75 Inside (Thermostat setting) : 90 Outside (Above ground : ti0 Outside (Below ground) : 87 Unconditioned Space : 100 Above Ceiling (Attic/Crawl Space) : 77 Concrete Slab (Ground temperature) : 80 Unconditioned Basement : 86 Below Floor Crawl Space : Applicable Temperatures: Above Ceiling: Attic or Crawl Space 58 47 50 55 49 46 48 5046 Below Floor. Crawl Space Exposed Walls: Above Ground Design Conditions Occupant Sensible Load (BTUH per person) : 250 Occupant Latent Load (BTUH per person) : 200 Duct Insulation Factor : 1 Duct Temperature Difference (Summer) : 30 Duct Temperature Difference (Winter) : 25 Humidity Difference Inside/Outside % (Summer) : 50 Humidity Difference Inside/Outside °tenter) : 56 Fresh Air Per Person (CFM) : 2 Air Change Factor (Air change per hour) : .5 Space Shading Factor : .6 Air Handler Design Cooling (CFM per ton) : 400 Hydronic Heat (STUN per linear ft : 500 Calculated Room Results - Wall Heat Gain (BTUH) : 226 Ceiling or Roof Heat Gain (BTUH) : 1578 Floor Heat Gain (BTUH) : 201 Glass Heat Gain (BTUH) : 443 Exterior Door & North Window Heat Gain (BTUH) : 113 Solar Heat Gain (BTUH) : 3096 Total Transmission Heat Gain (BTUH) : 5657 Insulation Values (U- Factors) Exposed Walls (Above Ground) : Exposed Walls (Below Ground) : Partitions : Roof/Ceiling : Floor (Above basement) : Floor (Concrete slab) : Floor (Between conditioned spaces) : Doors : Windows : Summer Heat Gains Appliance/Elec Motor Latent Heat Gain (BTUH) : Appliance/Elec Motor Sensible Heat Gain (BTUH) Ventilation Latent Heat Gain (BTUH) : Ventilation Sensible Gain (STUN) : Summer Total Latent Heat Gain: Summer Total Sensible Heat Gain (STUN) : TOTAL SUMMER COOLING LOAD (BTUH) : Calculated Room Results - Winter Heat Losses Transmission Heat Losses (BTUH) : -89939 Latent Ventilation Heat Losses (BTUH) : Sensible Ventilation Heat Losses (BTUH) : 175 Hydronic Heat(Linear Ft) : TOTAL WINTER HEATING LOAD (BTUH) : Calculated Totals for Entire Structure Size of Structure (Sq. Ft.): 1116 Total Sensible Heat Gain (BTUH): Total Heat Loss (BTUH): - 377592 Total Cooling Gain (STUN): Total Hydronic Heat (Linear Ft.): - 755.18 Total Cooling Requirement (Tons): Total Latent Heat Gain (BTUH): 4530 Total Cooling CFM: .080 .5 .075 0.287 .083 .001 .287 .500 .900 0 :1194 492 238 492 7089 7581 551 -178 -89213 24958 29486 2.46 806 Disclaimer These computed results should be treated as estimates only and should be viewed as only one of the many tools required for a professional installation. The installing contractor's experience and expert judgement are also major factors in sizing and installing a complete system. The weather, customer usage, duct installation, and structure design may vary on each estimate and should be taken into account Correct system sizing is based on the systems ability to meet both latent and sensible heat requirements, not just total BTUs. Prepared 8/10/2011 using O'Brien Quick Loads Pro - Version 1.01 - SN: XX)00000(40000( To whom it may concern: Heat Load Detail Report for M.R. AND RAFAEL PEREZ Room 5 of 8 Room Specifications: BED RM. #2 Room Length (Ft.) : 11.5 Sq. Ft windows facing NE & NW: Room Width (Ft) : 12 Sq. Ft windows facing South: Sq. Ft windows facing SE & SW: Number of Exterior Doors: Sq. Ft. Exterior Doors: Number of People in Room: 2 Room Height (Ft.) : 8 Exposed Wall Length (Ft.) : 11.5 Wall against unconditioned room (Ft) :— Sq. Ft windows facing North: — Sq. Ft windows facing E & W: 12 Watts Incandescent Light Watts Flourescent Light Duct Length from A/H to room: Number of Large Electric Motors: Average Electric Motor Horsepower. BTUH Appliance Sensible Heat BTUH Appliance Latent Heat Indoor /Outdoor Design Temperatures (degrees Farenheit) Winter: 75 Inside (Thermostat setting) : 90 Outside (Above ground : ti0 Outside (below ground) : 87 Unconditioned Space : 100 Above Ceiling (Attic/Crawl Space) : 77 Concrete Slab (Ground temperature) : 80 Unconditioned Basement : 86 Below Floor Crawl Space : Summer: Inside (Thermostat setting) : Outside (Above ground): Outside (below ground): Unconditioned Spam : Above Ceiling (Attic/Crawl Space) : Concrete Slab (Ground temperature) : Unconditioned Basement : Below Floor Crawl Space : Applicable Temperatures: na Design Conditions Occupant Sensible Load (BTUH per person) : 250 Occupant Latent Load (BTUH per person) : 200 Duct Insulation Factor : 1 Duct Temperature Difference (Summer) : 30 Duct Temperature Difference (Winter) : 25 Humidity Difference Inside/Outside % (Summer) : 50 Humidity Difference Inside/Outside %(Winter) : 56 Fresh Air Per Person (CFM) : 2 Air Change Factor (Air change per hour) : .5 Space Shading Factor : .6 Air Handler Design Cooling (CFM per ton) : 400 Hydronic Heat (BTUH per linear ft : 500 Calculated Room Results - Wall Heat Gain (BTUH) : 0 Ceiling or Roof Heat Gain (BTUH) : 0 Floor Heat Gain (BTUH) : 0 Glass Heat Gain (BTUH) : 0 Exterior Door & North Window Heat Gain (BTUH) : 0 Solar Heat Gain (BTUH) : 0 Total Transmission Heat Gain (BTUH) : 0 Insulation Values (U- Factors) Exposed Walls (Above Ground) : Exposed Walls (Below Ground) : Partitions : Roof/Ceiling : Floor (Above basement) : Floor (Concrete slab) : Floor (Between conditioned spaces) : Doors : Windows: 58 47 50 55 49 46 48 5046 .080 .5 .075 0.287 .083 .001 .287 .500 .900 Summer Heat Gains Appliiance/Elec Motor Latent Heat Gain (BTUH) : 0 Applianc e/Elec Motor Sensible Heat Gain (BTUH) :0 Ventilation Latent Heat Gain (BTUH) : 0 Ventilation Sensible Gain (BTUH) : 0 Summer Total Latent Heat Gain: 0 Summer Total Sensible Heat Gain (BTUH) : 0 TOTAL SUMMER COOLING LOAD (BTUH) : 0 Calculated Room Results - Winter Heat Losses Transmission Heat Losses (BTUH) : 0 Latent Ventilation Heat Losses (BTUH) : Sensible Ventilation Heat Losses (BTUH) : 0 Hydronic Heat(Linear Ft) : TOTAL WINTER HEATING LOAD (BTUH) : Calculated Totals for Entire Structure Size of Structure (Sq. Ft.): 1116 Total Sensible Heat Gain (STUN): Total Heat Loss (BTUH): - 377592 Total Cooling Gain (BTUH): Total Hydronic Heat (Linear Ft.): - 755.18 Total Cooling Requirement (Tons): Total Latent Heat Gain (BTUH): 4530 Total Cooling CFM: 0 0 0 24958 29486 2.46 806 150 Disclaimer These computed results should be treated as estimates only and should b9 viewed as only one of the many tools required for a professional installation. The installing contractor's experience and expert judgement are also major factors in sizing and installing a complete system. The weather, customer usage, duct installation, and structure design may vary on each estimate and should be taken into account. Correct system sizing is based on the systems ability to meet both latent and sensible heat requirements, not just total BTUs. •wr. Prepared 8/10/2011 using O'Brien Quick Loads Pro - Version 1.01 - SN: XX400000C -XXXXX To whom it may concern: Heat Load Detail Report for M.R. AND RAFAEL PEREZ Room 6 of 8 Room Specifications: BATH RM. Room Length (Ft) : 5 Sq. Ft windows facing NE & NW: Room Width (Ft) : 8.5 Sq. Ft windows facing South: Room Height (Ft.) : 7 Sq. Ft windows facing SE & SW: Exposed Wall Length (Ft.) : 5 Number of Exterior Doors: Wall against unconditioned room (Ft) :— Sq. Ft Exterior Doors: Sq. Ft windows facing North: — Number of People in Room: Sq. Ft windows facing E & W: 6 Watts Incandescent Light: Watts Flourescent Light Duct Length from AM to room: Number of Large Electric Motors: Average Electric Motor Horsepower. BTUH Appliance Sensible Heat BTUH Appliance Latent Heat Indoor/Outdoor Design Temperatures (degrees Farenheit) Winter. 75 Inside (Thermostat setting) : 90 Outside (Above ground : 80 outside (below ground) : 87 Unconditioned Space : 100 Above Ceiling (Attic/Crawl Space) : 77 Concrete Slab (Ground temperature) : Unconditioned Basement : Below Floor Crawl Space : Summer: inside (Thermostat setting) : Outside (Above ground): Outside (below ground): Unconditioned Space : Above Ceiling (Attic/Crawi Space) : Concrete Slab (Ground temperature) : Unconditioned Basement : Below Floor Crawl Space : 58 47 50 55 49 46 80 48 86 Applicable Temperatures: na Design Conditions Occupant Sensible Load (BTUH per person) : 250 Occupant Latent Load (BTUH per person) : 200 Duct Insulation Factor : 1 Duct Temperature Difference (Summer) : 30 Duct Temperature Difference (Winter) : 25 Humidity Difference Inside/Outside % (Summer) : 50 Humidity Difference Inside/Outside %(Winter) : 56 Fresh Air Per Person (CFM) : 2 Air Change Factor (Air change per hour) : .5 Space Shading Factor : .6 Air Handler Design Cooling (CFM per ton) : 400 Hydronic Heat (BTUH per linear ft : 500 Calculated Room Results - Wall Heat Gain (BTUH) : 0 Ceiling or Roof Heat Gain (BTUH) : 0 Floor Heat Gain (BTUH) : 0 Glass Heat Gain (BTUH) : 0 Exterior Door & North Wmdow Heat Gain (BTUH) : 0 Solar Heat Gain (BTUH) : 0 Total Transmission Heat Gain (BTUH) : 0 Insulation Values (U- Factors) Exposed Walls (Above Ground) : Exposed Walls (Below Ground) : Partitions : Roof /Ceiling : Floor (Above basement) : Floor (Concrete slab) : Floor (Between conditioned spaces) : Doors : Windows : 5046 .080 .5 .075 0.287 .083 .001 .287 .500 .900 Summer Heat Gains Appliance/Elec Motor Latent Heat Gain (BTUH) : 0 Applianc e/Eiec Motor Sensible Heat Gain (BTUH) :0 Ventilation Latent Heat Gain (BTUH) : 0 Ventilation Sensible Gain (BTUH) : 0 Summer Total Latent Heat Gain: 0 Summer Total Sensible Heat Gain (BTUH) : 0 TOTAL SUMMER COOLING LOAD (BTUH) : 0 Calculated Room Results - Transmission Heat Losses (BTUH) : 0 Sensible Ventilation Heat Losses (BTUH) : 0 Winter Heat Losses Latent Ventilation Heat Losses (BTUH) : Hydronic Heat(Linear Ft.) : TOTAL WINTER HEATING LOAD (BTUH) : Calculated Totals for Entire Structure Size of Structure (Sq. Ft): 1116 Total Sensible Heat Gain (BTUH): Total Heat Loss (BTUH): - 377592 Total Cooling Gain (BTUH): Total Hydronic Heat (Linear Ft): - 755.18 Total Cooling Requirement (Tons): Total Latent Heat Gain (BTUH): 4530 Total Cooling CFM: 0 0 0 24958 29486 2.46 806 48 Disclaimer These computed results should be treated as estimates only and should be viewed as only one of the many tools required for a professional installation. The installing contractor's experience and expert judgement are also major factors in sizing and installing a complete system. The weather, customer usage, duct installation, and structure design may vary on each estimate and should be taken into account Correct system sizing is based on the systems ability to meet both latent and sensible heat requirements, not just total BTUs. Prepared 8/10/2011 using O'Brien Quick Loads Pro - Version 1.01- SN: XX XXXXXX)O(XXX To whom it may concern: Heat Load Detail Report for M.R. AND RAFAEL PEREZ Room 7 of 8 Room Specifications: BED RM. #1 t5 Sq. Ft windows facing NE & NW: — 2 Sq. Ft windows facing South: 12 Sq. Ft windows facing SE & SW: — 24 Number of Exterior Doors: — Sq. Ft Exterior Doors: Number of People in Room: 2 Room Length (Ft) : 1 Room Width (Ft.) : 1 Room Height (Ft.) : 8 Exposed Wall Length (Ft.) Wall against unconditioned room (Ft.) :— Sq. Ft windows facing North: Sq. Ft windows facing E & W: 12 Summer: Inside (Thermostat setting) : Outside (Above ground): Outside (below ground): Unconditioned Space : Above Ceiling (Attic/Crawi Space) : Concrete Slab (Ground temperature) : Unconditioned Basement : Below Floor Crawl Space : Watts Incandescent Light: Watts Flourescent Light Duct Length from AM to room: Number of Large Electric Motors: - - Average Electric Motor Horsepower. — BTUH Appliance Sensible Heat — BTUH Appliance Latent Heat 150 IndoorlOutdoor Design Temperatures (degrees Farenheit) Winter: 75 Inside (Thermostat setting) : 90 Outside (Above ground : f3U Outside (tretow ground) : 87 Unconditioned Space : 100 Above Ceiling (Attic/Crawl Space) : 77 Concrete Slab (Ground temperature) : 80 Unconditioned Basement : 86 Below Floor Crawl Space : 58 47 50 55 49 46 48 5046 Applicable Temperatures: Above Ceiling: Attic or Crawl Space Below Floor. Crawl Space Exposed Walls: Above Ground Design Conditions Occupant Sensible Load (BTUH per person) : 250 Occupant Latent Load (BTUH per person) : 200 Duct Insulation Factor : 1 Duct Temperature Difference (Summer) : 30 Duct Temperature Difference (Winter) : 25 Humidity Difference Inside/Outside % (Summer) : 50 Humidity Difference Inside/Outside %(Winter) : 56 Fresh Air Per Person (CFM) : 2 Air Change Factor (Air change per hour) : .5 Space Shading Factor : .6 Air Handler Design Cooling (CFM per ton) : 400 Hydronic Heat (BTUH per linear ft : 500 Calculated Room Results - Wall Heat Gain (BTUH) : 230 Ceiling or Roof Heat Gain (BTUH) : 990 Floor Heat Gain (BTUH) : 126 Glass Heat Gain (BTUH) : 295 Exterior Door & North Window Heat Gain (BTUH) : 0 Solar Heat Gain (BTUH) : 1548 Total Transmission Heat Gain (BTUH) : 3190 Calculated Room Results Transmission Heat Losses (BTUH) : -56391 Sensible Ventilation Heat Losses (BTUH) : 110 Size of Structure (Sq. Ft.): Total Heat Loss (BTUH): Total Hydronic Heat (Linear Ft.): Total Latent Heat Gain (STUN): Insulation Values (U- Factors) Exposed Walls (Above Ground) : Exposed Walls (Below Ground) : Partitions : Roof/Ceiling : Floor (Above basement) : Floor (Concrete slab) : Floor (Between conditioned spaces) : Doors : Windows: .080 .5 .075 0.287 .083 .001 287 .500 .900 Summer Heat Gains Appliance/Elec Motor Latent Heat Gain (BTUH) : 400 Applianc e/Elec Motor Sensible Heat Gain (BTUH) :1012 Ventilation Latent Heat Gain (BTUH) : 309 Ventilation Sensible Gain (BTUH) : 149 Summer Total Latent Heat Gain: 709 Summer Total Sensible Heat Gain (BTUH) : 4351 TOTAL SUMMER COOLING LOAD (BTUH) : 5059 - Winter Heat Losses Latent Ventilation Heat Losses (BTUH) : Hydronic Heat(Linear Ft) : 346 -112 TOTAL WINTER HEATING LOAD (BTUH) : -55935 Calculated Totals for Entire Structure 1116 Total Sensible Heat Gain (BTUH): - 377592 Total Cooling Gain (BTUH): -755.18 Total Cooling Requirement (Tons): 4530 Total Cooling CFM: 24958 29486 2.46 806 Disclaimer These computed results should be treated as estimates only and should be viewed as only one of the many tools required for a professional installation. The installing contractor's experience and expert judgement are also major factors in sizing and installing a complete system. The weather, customer usage, duct installation, and structure design may vary on each estimate and should be taken into account Correct system sizing is based on the systems ability to meet both latent and sensible heat requirements, not just total BTUs. Prepared 8/10/2011 using O'Brien Quick Loads Pro - Version 1.01 - SN: XX X)000(X XX)0CX To whom it may concern: Heat Load Detail Report for M.R. AND RAFAEL PEREZ Room 8 of 8 Room Length (Ft.) : 5 Room Width (Ft.) : 3.5 Room Height (Ft.) : 8 Exposed Wall Length (Ft.) : Wall against unconditioned room (Ft.) :- Sq. Ft windows facing North: — Sq. Ft windows facing E & W: Room Specifications: HALL Sq. Ft windows facing NE & NW: — Sq. Ft windows facing South: — Sq. Ft windows facing SE & SW: — Number of Exterior Doors: — Sq. Ft. Exterior Doors: Number of People in Room: Watts Incandescent Light Watts Flourescent Light Duct Length from A/H to room: Number of Large Electric Motors: Average Electric Motor Horsepower. BTUH Appliance Sensible Heat BTUH Appliance Latent Heat Indoor/Outdoor Design Temperatures (degrees Farenheit) Summer: Winter: Inside (Thermostat setting) : Outside (Above ground): Outside (below ground): Unconditioned Space : Above Ceiling (Attic/Crawl Space) : Concrete Slab (Ground temperature) : Unconditioned Basement : Below Floor Crawl Space : 75 Inside (Thermostat setting) : 90 Outside (Above ground : tj0 Outside (grow ground) : 87 Unconditioned Space : 100 Above Ceiling (Attic/Crawl Space) : 77 Concrete Slab (Ground temperature) : 80 Unconditioned Basement : 86 Below Floor Crawl Space : 58 47 bU 55 49 46 48 5046 Applicable Temperatures: Above Ceiling: Attic or Crawl Space Below Floor Crawl Space Exposed Walls: Above Ground Design Conditions Occupant Sensible Load (BTUH per person) : 250 Occupant Latent Load (BTUH per person) : 200 Duct Insulation Factor : 1 Duct Temperature Difference (Summer) : 30 Duct Temperature Difference (Winter) : 25 Humidity Difference Inside/Outside % (Summer) : 50 Humidity Difference Inside/Outside %(Winter) : 56 Fresh Air Per Person (CFM) : 2 Air Change Factor (Air change per hour) : .5 Space Shading Factor : .6 Air Handler Design Cooling (CFM per ton) : 400 Hydronic Heat (BTUH per linear ft : 500 Calculated Room Results Wall Heat Gain (BTUH) : 0 Ceiling or Roof Heat Gain (BTUH) : 126 Floor Heat Gain (BTUH) : 16 Glass Heat Gain (BTUH) : 0 Exterior Door & North Window Heat Gain (BTUH) : 0 Solar Heat Gain (BTUH) : 0 Total Transmission Heat Gain (BTUH) : 142 Calculated Room Results Transmission Heat Losses (BTUH) : -7200 Sensible Ventilation Heat Losses (BTUH) : 14 Size of Structure (Sq. Ft.): Total Heat Loss (STUN): Total Hydronic Heat (Linear Ft.): Total Latent Heat Gain (BTUH): Insulation Values (U- Factors) Exposed Walls (Above Ground) : Exposed Walls (Below Ground) : Partitions : Roof/Ceiling : Floor (Above basement) : Floor (Concrete slab) : Floor (Between conditioned spaces) : Doors : Windows : .080 .5 .075 0287 .083 .001 .287 .500 .900 - Summer Heat Gains Appliance/Elec Motor Latent Heat Gain (BTUH) : 0 Appliance/Elec Motor Sensible Heat Gain (BTUH) :1053 Ventilation Latent Heat Gain (BTUH) : 39 Ventilation Sensible Gain (BTUH) : 19 Summer Total Latent Heat Gain: 39 Summer Total Sensible Heat Gain (BTUH) : 1213 TOTAL SUMMER COOLING LOAD (STUN) : 1252 - Winter Heat Losses Latent Ventilation Heat Losses (BTUH) : Hydronic Heat(Linear Ft.) : 44 -14 TOTAL WINTER HEATING LOAD (STUN) : -7142 Calculated Totals for Entire Structure 1116 Total Sensible Heat Gain (BTUH): - 377592 Total Cooling Gain (BTUH): -755.18 Total Cooling Requirement (Tons): 4530 Total Cooling CFM: 24958 29486 2.46 806 60 1 .250 Disclaimer These computed results should be treated as estimates only and should be viewed as only one of the many tools required for a professional installation. The installing contractor's experience and expert judgement are also major factors in sizing and installing a complete system. The weather, customer usage, duct installation, and structure design may vary on each estimate and should be taken into account. Correct system sizing is based on the systems ability to meat both latent and sensible heat requirements, not just total BTUs. Prepared 8/10/2011 using O'Brien Quick Loads Pro - Version 1.01 - SN: XX)00000()000(X