Loading...
RF-11-1723Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Inspection Number: INSP - 164638 Scheduled Inspection Date: October 05, 2011 Inspector: Bruhn, Norman Owner: PERWIN, AMY Permit Number: RF -9 -11 -1723 Job Address: 800 NE 95 Street Miami Shores, FL Project: <NONE> Contractor: A PALMER ROOFING, INC. Permit Type: Roof Inspection Type: Final Roof Work Classification: Repair Roof Phone Number Parcel Number 1132060410010 Phone: (305)232 -9211 Building Department Comments REPAIR TO VALLEY AT FRONT TILE ROOF. REMOVE TILE AS NEEDED AT BOTH SIDES OF VALLEY. REMOVE AND RESEAL PAPER AS NEEDED. APPLY NEW TILE TO MACH EXISTING. Passed Inspector Comments Failed Correction Needed Re- Inspection Fee No Additional Inspections can be scheduled until re- inspection fee is paid. October 04, 2011 For Inspections please call: (305)762 -4949 Page 28 of 49 Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 ^ , �� Tel: (305) 795.2204 Fax: (305) 756.8972 / \ 1 St INSPECTION'S PHONE NUMBER: (305) 762.4949 BUILDING Permit No. PERMIT APPLICATION Master Permit No. FBC 20 1-723 Permit Type: BUILDING ROOFING /1 OWNER: Name (Fee Simple Titleholder): F� wtiy L lam` e. \`4 +r1 Phone #: 303-#757-4/0X2--' Address: 0QO t4•1E. c;5 S#rre' ' City: t A A\ S I� bre £ State: Ft- Zip: 33/38 Tenant/Lessee Name: 14 Phone #: Email: JOB ADDRESS: boo t4 • E. tS si-re, A- City: Miami Shores County: Miami Dade Zip: 33138 Folio/Parcel #: Is the Building Historically Designated: Yes NO Flood Zone: CONTRACTOR: Company Name: A- ?CX\ W e r .b0 h& -1 G• Phone #: 3 i) S- a 3 a -c1 a i Address: ql 10 0 S' w • Ho i.71 CA-, City: tq1CAW. to 1—t Qualifier Name: h, 'Irak) f4AvYlp,r State Certification or Registration #: C. C � t 3 a 6 5 t� Certificate of Competency! #: Contact Phone #: •� a S ' s a '" }}� v Email Address: G.�Gi I PNe r' r0 0'rt /3 g ✓�21I Its �10 '� l ,n DESIGNER: Architect/Engineer: N a- Phone #: 3 a s- IV VT Value of Work for this Permit: $ S Squar ear Footage . f Work: 410 s .4- Type of Work: ❑Addition ❑Alteration ❑ ew v • epair/Replace Demolition Description of Work: , r- A,��; Ci,4- �4r \e_ rta4. State: Ft° Zip: 33 t r 7 Phone #: 3 OS ° 23 Z -ct d. d Submittal Fee $ Scanning Fee $ Notary $ Training/Education Fee $ Double Fee $ Structural Review $ Permit Fee $ lo° e Radon Fee $ CCF $ CO /CC $ DBPR $ Bond $ Technology Fee $ TOTAL FEE NOW DUE $ Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City I.) I 4— State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature weer or Agent Contractor The foregoing instrument Vwas acknowledged before me this The foregoing instrument was acknowledged before me this 1 day of r °,20I9,by day °..J ` -,20 11, by who is +'sonal y kno o me or who has produced who i. , ersonally kno to me or who has produced As identification and who did take an oath. as identification and who did take an oath. NOTARY PUBLIC: Sign: Print: My Co XOl'%a% JOANNE KNESKI Notary Public - State of Florida pi. My Comm. Expires Oct 9, 2014 p�g494 Com s on E 1191 ************* 9:9 11 qpF )e�dtoY:F�Y�Y4 nnel *n*W*3eko *** APPROVED BY (Revised 07 /10 /07XRevised 06110 /2009XRevised 3/15/09) NOTARY PUBLIC: Sign: Print: My Comm JOANNE KNESKI Notary Public - State of Florida • gl My Comm. Expires Oct 9, 2014 :; o,o;, Commission # EE 1191 *********************** ******** *** **V4 *' ******* ******* Y********* k** Plans Examiner Structural Review Zoning Clerk Sep 21 11 12:24p Andrew Palmer Roofing,Inc 3052329361 p.3 415583 -4 THIS IS-NOT ABEL - DO NOT PAY • RENEWAL' 433988-3 eu W nn N WWOOFING INC 4156 SW 70 CT 33155 UNIN DADE COUNTY STATE EC 26750 OwPALMER ANDREW ROOFING INC SBc1 �'egiFIVent.TY BUILDING CONTRACTOR btORKE5IS THIS IS ONLY A LOCAL BUSINESS TAX RECEIPT. IT DOES NOT PERMIT THE HOLDER TO VIOLATE ANY �CISTINO REGULATORY OR ZONING LAWS OF THE COVN-Y OR CITIES. NOR DOES IT EXEMPT 'HE HOLDER FROM ANY OTHER PERMIT OR LICENSE REQUIRED BY LAW. THIS IS ROTA CER'TIFICAT.CN OF THE HOLDER'S'QUALIFICA- T1ONS. PAYMENT RECEIVED MIAMPDADE COUNTY TAX COLLECTOR: 07/12/2011 64080000413 000075.00 SEE OTHER SIDE DO NOT FORWARD PALMER ANDREW ROOFING INC ANDREW N PALMER PRES 3612 BAYVIEW RD MIAMI FL 33133 FIRST. - GLASS. U.S. POSTAGE PAID M1AMI, FL PERMIT NO: 231 JJI111 i�tt 111l1111l11Ii111I11i1i111 HISS'S 11 it 11 t1 ti �li Sep 21 11 12:40p Andrew Palmer Roofing,Inc «1i 21111 11: 34 3056668014 MCCARTNEY INS 3052329361 p.1 PAGE 01/01 OP ID: AM '4 °~ CERTIFhaeATE OF LIABILITY INSL ANCE THIS CERTIFICATE IS ISSUED AS A MATTER OF JNFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER,. THIS CER11FtCATC DOES NOT ATFIRMATWVEt_Y OR NF0 ATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTftUTE A CONTRACT BeriWEEN THE ISSUING rrt$UREIR(5), AUTHORIZED REPRESENTATIVE OR PRODUCER, AND THE CERTIFICATE HOLDER. IMPORTANT: IF the ato holder Is an ADDITIONAL INSURED, the polIeypeej muut ho rrtdcrsed, tf SUBROGATION 1S WAIVED, 6ubject to the terms and conditions of the .policy, certain policies may require an endorsement. A statement an thin certificate does not confer rights to the certificate holder In lieu of such endorssement(c). DATE SIMMI n1YYTY) 09112/11 pnorcrcen McCartney Insurance Agency,Ine 6739 131r Rood MVilamt, FL 331553705 Don McCartney INSURED Andrew Palmer Roofing, inc. 9700 SW 10B St, MlaanE,, FL 33457 305488 -4444 CONTACT Kama PRONL �a1Se 9ER _ ANDRE -1 I PAR IA/C,010): • INSURSRISI APR/NDINe COVERAGE INSURER A: Starr Indemnity J31 Liability INSURER a: NATO M INSUIWJ G r INSURER D r. INSURER E INSURER F. ON NUMBER: THIS IS TO CERTIFY THAT THE POLICIES INDICATED, NOTWITHSTANDING ANY REQUIREMENT, CERTIFICATE MAY DE ISSUED OR MAY EXCLUSIDNSANO CONDITIONS OFSUCH OF INSURANCE PERTAIN, POLICIES. gi ,p L(STED HELM/ HAVE BEEN TERM OR CONDITION OF ANY THE INSURANCE AFFORDED BY LIMITS SHOWN MAY HAVE BEEN ISSUED TO CONTRACT THE POLICIES REDUCED BY LM '•• CY Ai THE INSURED OR OTHER DESCRIBED PAID CLAIMS. FML•,a au 01512 NAMED ABOVE FOR THE DOCL1MENT W1T4 RESPECT HEREIN IS SUBJECT TO POLICY PERIOD TO WHICH THIS ALL THE TERMS, 7yTg TYPE OF INSURANCE PDUCYNUMBER a 1,000,000 A GENERA. LIAaIUTY COMMERCIAL GENERAL L'ABIlIY J OCCUR 11 -792 011/115/11 EACH OCCURRENCE X °AA O Tl J thlr eel i 50 004 r 1 CLAtM9•MADE ►... M b p (hint 0IMPR1019 $ $ 5,000 1,000,000 _ PERSONAL 8 ACV INJURY !!� 'GENERAL AGGREGATE $ 2,000,000 AGGREGATE 'MT APPLIES PER: I POLICY n V& n LOC PRODUCTS • CO UPIOP AGO $ 2,000,000 �Ci —E7Ni $ AUTOMOBILE LI B1UTY ANY AUTO ALL OWNED AUTOS SCHEDULE° AUTOS HIRED AUTOS Nen -OwNED AUTOS COWNED SINOLE LIMB (EN,JJxNOenq 8 _ , BODILY INJURY (Per person) $ BODILY IIWURY (PAr saddent) $ ! PROPS DAMAGE (Pew aCCIdflnl) $ 1 a UMBRBL Uk L.IA9 EXCESSCIAE ..—, OCCUR CLAIM94UADE EACH OCCURRENCE S AGGREGATE 9 OEDUCTISI.E: R3LNTI• S WORKERS COMPENSATION AND EMPLOYERS' LIABILITY ANY RANEME OR& LITER/E O Elyyaeend.ddamm�pyqiIn NH) °ESC RIP'(IOR be 9P OPERATIONS Y N N!A WC STATU• ■ DTfI- Eo,. $ EL EACH ACCIDENT VE below E.L. DISEASE • SA EIaPLOYEE $ E.L. DISEASE - POLICY LIME? $ DESCRIPTION OF OP'ERATIONSILOCATIONSIVEIiCLES IAEacbAGORO ME, Addleane lRJMIW I, eSe1e ,FJla.1tmetaspewlaraqulavdt CERTIFICATE HOLDS R CANCELLATION CITYMIS CITY OF MIAMI SHORES Building Department 10050 N.E. 2ND AVENUE MIAMI SHORES„ FL 33130 SHOULD ANY OF THE ABOVE DESCRIBED POUCIE S BE CANCELLED BEFORE THE EXPIRATION RATE THEREOF, NOTICE MALL BE OELIVLRED IN ACCORDANCE WITH THE POLJCY PROVISIONS. AUTRDAIIEG REPA5DENTAnIVE Don McCartney ACORO 25 (2009109) L0 1988 -2009 ACORD CORPORATION. A0 rights reserved. The ACORD name and logo are registered marks of ACORD Sep 21 11 12:23p ACS. 8 Andrew Palmer Roofing,Inc p►TE PARE.' ':='• CONSTTRUCTTON= LICENSE.. 3052329361 pi The ROOFING .:' CONTRACTOR Named below IS CRRTIFIED'.: Under . 'the provisions of = Chapter 489 F.S Expiration date: • AUG 31, .. 2012 PALMER„......*: ANDREW N . ANDREW ;PALMER-' ROOFIN 9.700':. SW:.168 ".STREET 't�: MIAMI Sep 21 11 12:24p Andrew Palmer Roofing,Inc ISSUED TO: 3052329361 p.2 Issue Date: 1 /4/2011 FLORIDA ROOFING, SHEET METAL & AIR CONDITIONING CONTRACTORS ASSOCIATION, INC. SELF INSURERS FUND 1- 800 -767 -3772 • FAX (407) 671 -2520 CERTIFICATE OF INSURANCE COPY PROVIDED TO: Andrew Palmer Roofing, Inc. & Palmer & Feria 9700 Sw 168Th Street Miami, FL 33157 Village Of Miami Shores 10050 Ne 2Nd Ave. Miami Shores, FL 33138-2304 Attention: To Whom It May Concern Andrew Palmer Roofing, Inc. & Palmer & Feria Painting Corp. This is to Certify that 9700 Sw 168Th Street Miami, FL 33157 being subject to the provisions of the Florida Workers' Compensation Act, has secured the payment of compensation by insuring their risk with the FLORIDA ROOFING, SHEET METAL & AIR CONDITIONING CONTRACTORS ASSOCIATION SELF INSURERS FUND, P.O. Box 4907, Winter Park, FL 32793. COVERAGE NUMBER: 870- 033261 EFFECTIVE DATE: 1/1/2011 EXPIRATION DATE: 1/1/2012 LIMITS Workers' Compensation: Statutory - State of Florida Employers' Liability: $100,000.00 Each Accident $100,000.00 Disease, Each Employee $500,000.00 Disease, Policy Limit REMARKS: Non - cancelable, without 30 days prior written notice, except for non - payment of premium which will be a 10 day written notice. This certificate is issued as a matter of information only, is not a policy and of itself does not afford any insurance. Nothing contained in this certificate shall be constructed as extending coverage not afforded by the poticy(ies) shown above or as affording insurance to any insured not named above. This provides coverage for Florida policyholders and Florida domiciled employees only. By: Brett Stiegel, Administrator FRSA -SIF By: IL fO►1,& Debra Guidry, CPCU, Un • erwriting Manager FRSA -SIF ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Florida Building Code Editio High - Velocity Hurricane Zone Uniform Permit Ap I, zy�o Shoves \? 71ege, �,DpDO® /ED G DEPT ONT DATE alfrit I�C+r�T 1LCT TO COn)IPLIANCE WITH ALL FEDF�AL '� oi� - P•In �FCi -II ATI,�PI� �TATF. /\ ID C(�')N�Ft�ll � •� ! -1- - 1 •eu- Master Permit No Process Contractor's Name f--} VACv-1.1A.) .TCAA On 4.4( YtoUF \ 0, a 53o0 Ale c1 q ▪ sa-. AA; C A , F • 33 132 Job Address ❑ Low Slope ❑ Asphaltic Shingles ❑ Mechanically Fastened Tile Mortar /Adhesive Set Tile ❑ Metal Panel /Shingles ❑ Wood Shingles /Shakes ❑ Prescriptive BUR -RAS 150 ROOF TYPE ❑ New Roof ❑ Reroofing ❑ Recovering ROOF SYSTEM INFORMATION Low Slope Roof Area (SF) ( Repair ❑ Maintenance Steep Sloped Roof Area (SF) 2.9 Total (SF) Section B (Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. ti Vt. A`T 4 a FLORIDA BUILDING CODE — BUILDING I- dalvinizsd Metat- j 1 11023 1 1 Till Roof System Delivering Excellence Every Day' Roof System Manufacturer: Miami -Dade County Building Department Electronic Application Section 0 Sloped System Description Vie 'Roof .System `Monier Ufetlle NOtice of Acceptance Number (NOA): 107. 1023.12 Minimum Design WIrtd Pressures, If Applicable (from RAS 127 or Calculations): P1. 3.27 P2: P 3: 18.08 Maximum Design Wind Pressures, (From the NOA Spect is system) :140.4 1 Psi P111 In the specific roof assembly components. Ka component It net requnod, Insert not applldoble (hf.) in the text box. Roof Slope: %12" Roof Mean Height: 15 ft, Method of Tile Attachment: (Adhesive, Medium Paddy Polyfoam Polypra --1 tAiternete Method of Tile Attachment perNOA: Drip Edge Size & Gage: Drip Edge Material Type: Drip Edge Fastener Type: 1 -3" face 26 go.— 111 /4rsnails Hook Strip/Cleat gauge or weight: -- Select Hook Strip -- JUL 08,2009 12:02A ABC SUPPLY CO I Deck Type: 1--6/8" Plywood— Optional insulation: Optional Meltable Substrate: 1 Optional Nailable Substrate Attachment: 3asesheet Type: [30# astm d226 type 2 Fastener Type far Basesheet Attachment: 11 1/4 rs nails and 15/8 tin caps Tile Underlayment (Cap Sheet ) Type: P I LJ Tile Underlaymant Attachment Method: ,5 �.� '' Ad h e, y-c,Z. Tile Profile: Atlantis Slate I 3057518579 page 3. SECTION R4402.13 HIGH VELOCITY HURRICANE ZONES — REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS R4402.13.1 Scope. As it pertains to the section, it is the responsibility of roofing contractor to provide the owner with the required roofing permit, and to explain to the owner the content of the section. The provisions of Section R4402 govem the minimum requirements and standards of the industry for roofing system installations. Additionally, the following items should be addressed as part of the agreement between the owner ant the contractor. The owner's initial in the designated space indicates that the item has been explained. 1. Aesthetics - Workmanship: the workmanship provisions of Section R4402 are for the purpose of providing that the roof system meets the wind resistance and water instruction performance standards. Aesthetics (appearance) are not a consideration with respect to workmanship provisions. Aesthetic issues such as color or architectural appearance, that are not part of a zoning code, should be addressed as part of the agreement between the owner and the contractor. 2. ket Renailing wood decks: When replacing roofing, the existing wood roof deck may have to be renailed in accordance with the current provisions of Section R4403. (The roof deck is usually concealed prior to removing the existing roof system). 3. Common roofs: Common roofs are those which have no visible delineation between neighboring units (i.e., townhouses, condominiums, etc.) In buildings with common roofs, the roofing contractor and/or owner should notify the occupants of adjacent units of roofing to be performed. 4. , Exposed Ceiling: Exposed, open beam ceilings are where the underside of the roof decking can be viewed from below. The owner may wish to maintain the architectural appearance; therefore, roofing nail penetration of the underside of the decking may not be acceptable. This provides the option of maintaining the appearance. 5. ifsiN Ponding water: The current roof system and /or deck of the building may not drain well and may cause water to pond (accumulate) in low -lying areas of the roof. Pounding can be an indication of structural distress and may require the review of a professional structural engineer. Pounding may shorten the life expectancy and performance of the new roofing system. Pounding conditions may not be evident until the original roofing system is removed. Pounding conditions should be corrected. 6. AV" Overflow scuppers (wall outlets): It is required that rainwater flows off so that the roof is not overloaded from a buildup of water. Perimeter /edge wall or other roof extension may block this discharge if overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in accordance with the requirements of Sections R4402, R4403 and R4413. 7. Ventilation: Most roof structures should have some ability to vent natural airflow through the interior of the structure assembly (the building itself). The existing amount of attic ventilation shall not be reduced. It may be beneficial to consider additional venting which can result in extending the service life of the roof. 6^Z-70 er/ ent's Signature Date Contractor Signature Date Revised on 7/9/2009 LD UUELDING CODE COMPLIANCE OFFICE (BCCO) PRODUCT' CONTROL DIVISION NOTICE OF ACCEPTANCE (NOA) Monier Lifetile, LLC 200 Story. Reed Lake Wales, FL 33898 SCOPE: MIAMI -BADE COUNTY, FT;.ORIDA METRO -DAVE MAGMA etnia NO 140 WEST FLAGLER STREET, SU11TE 1603 MIAMI, FLORIDA 33130.1563 (305) 375-2901 FAX (305) 375-2905 This NOA is being issued under the applicable tines and regulations governing the use of construction md;terials. The documentation submitted has been reviewed by Miami -Dade County Product Control Division and accepted by the Board of Rules and Appeals (BORA) to be used in Miami Dade County and other areas where allowed by the Authority /raving Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Division (In Miami Dade County) and/or the AHJ (in area other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the tight to revoke this acceptance, if it is determined by Miami -Dade County Product Control Division that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Atlantis Shake & State Concrete Roof Tile LABELING; Each unit shah bear a permanent label with the manufacturer's name or logo, city, state and .following statement "Miaarhi Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the atoneable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change In the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement alum product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, than it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and ARE be available for inspection at the job site at the request of the Building Official. ilia renews NOA #02-1211.08 and consists of pages 1 through 7. The submitted documentation was reviewed by Alex Tigers. JUL 08,2009 12:03A ABC SUPPLY CO I 3057518579 NOA No.: 07- 1023.12 Expiration Data: 12/102 Approval Date: 12/13/07 Page 1 of 7 page 3 ROOFING ASSEMBLY APPROVAL wry: Roofing Su ors: Flat Profile Roofing Tiles Concrete 1. SCOPE This renews a system using Monier Lifet 1e Atlantis Shake & Slate Concrete Roof Tile, as manufhctured Monier Lifeetile LLC in Boca Raton, FL and described in Section 2 of this Notice of Acceptance. For locations where the pressure requirements, as determined by applicable Building Code does not exceed the design pressure values obtained by calculations in compliance with RAS 127 using the values listed in section 4 herein. The attachment calculations shall be done as a moment based system. 2. PRODUCT DESCRIPTION MUL tctsrad >X Applicant Monier Lifatile Atlantis Shake and Slate Tile Trim Pieces Pimaenslons, 1= 16" w 10" 1 V4" thick I= varies w = Varies varying thickness 2.1 SUBMITTED EVIDENCE: TjaMOIICY Redland Technologies The Center for Applied Bngineering, buc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. JUL 08,2009 12:03A ABC SUPPLY CO 1 Test S—.riona TAS 112 TAS 112 Test 1dei itifeer 7161 -03 Appendix III 94 -060A' 94-084 25- 7094.2 25-7094-8 25- 7094 -5 Product IhOgdOgn ' Flat, interlocking, high pressure extruded concrete shake and slate roof the equipped with two nail holes. For direct deck, mortar or adhesive set applications. Accessory trim, concrete roof pieces for use at hips, rakes, ridges and valley terminations, Manufactured for each tile profile. Test Nione/Rept rt Static Uplift Testing PA 102 & PA 102(A) Static Uplift Testing PA 101 (Mortar Set) (Adhesive Set). Static Uplift Testing PA 102 (4" Headlap, Nails, Direct Deck, New Construction) Static Uplift Testing PA 102 (4" Headlap, Nails, Battens) Static Uplift Testing PA 102 (4" Headlap, Nails, Direct Deck, Reoover/Reroof) 3057518579 Dec. 1991 March, 1994 May 1994 Oct 1994 Oct. 1994 Oct, 1994 NOA No.: 07. 1023.12 Expiration Date: 12/16/12 Approval Date: 12/13/07 Page 2 of 7 page 4 1,04Eilsi The Center for Applied Ong, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied Enging, Inc. Redland Technologies Redland Technologies Redland Technologies Redland Technologies The Centex for Applied Engbteering, Inc. Professional Service Industries, Inc. Ce lotex Commotion Testing Service Walker Engineering, Inc. Welker Engineering. Inc. Walker Ewing, Inc. Walker Engineering, Inc. Walker Engineering, Inc. Walker Engineering, Inc. Walker Engineering, Inc. Walker Engineering, Inc. Nutting Engineerins Test Identifier 25- 7183 -6 25-7183-5 25- 7214 -1 25-7214-5 716I -03 Appendix 11 Letter Dated Aug. 1,1994 P0631 -01 P0402 Ptoject No. 307025 Test #MDC -77 22447099 JUL 08,2009 12:04A ABC SUPPLY CO I 520109 -1 520111 -4 520191 -1 Calculations Calculations Calculations Calculations Caiculatit ons Calculations Calculations Calculations TAS -112 Test Name ort Static Uplift Testing PA 102 (2 Quik Drive Screws, Direct Deck) Static Uplift Testing PA 102 (2 Quit- Drive Screws, Battens) Static Uplift Testing PA 102 (1 Quilt-Drive Screw, Direct Deck) Static Uplift Testing PA 102 (1 Quik chive Screw, Battens) Wind Tunnel Testing PA 108 (Nail-On) Wind Tunnel Testing PA 108 (Nail -On) Wind Tunnel Tending PA 108 (Mortar Set) Withdrawal *Resistance Testing of screw vs. smooth shank nails Wind Driven Rain PA100 Physical Properties PA 112 Static Uplift Testing PA 101 Aerodynamic Multiplier Moment of Gravity 25 -7094 25 -7496 25 -7584 25- 7804b -8 25- 7804 -4 & 5 25- 7848 -6 25 -7183 Aerodynamic Multipliers Two Patty Adhesive Set System 13343.1 3057518579 Rag Feb. 1995 Feb. 1995 March, 1995 March, 1995 Dec. 1991 Aug. 1994 July 1994 Sept. 1993 Oct. 1994 Sept. 1994 Dec. 1998 March 1999 October 2007 August 2007 February 1996 April 1996 December 1.996 Merch1995 April 1999 April 1999 June 2007 IYOA No.: 07- 1023.12 Expiration Date: 12/16/12 Approval Date: 12/13/07 Page 3 of 7 page 5 3. LIMITATIONS 3,1 Fire classification is not part of this acceptance. 12 For mortar or adhesive set tile applications, a. static field uplift test shall be performed in accordance with RAS 106. 3.3 Applicai t shall retain the services of a Miami -Dade County Certified Laboratory to petfotm quarterly test in accordance with TAS 112, appendix `A'. Such testing shall be submitted to the Building Code Compliance Office for review. 3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed section 4.1 herein. 3.5. 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stag otherwise by the underlayment material manufacturers published literature. 3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with applicable building code. 3.7 May be installed on slopes 7:12 and greater with a minimum of two screws. 4. INSTALLATION 4.1 Monier Lifetile Atlantis Shake and Slate Concrete Roof Tile and its components shall be installed in strict compliance with Roofing Application Standard RAS 118, RAS 119, and RAS 120. 4.2 Data. For Attachment Calculations Table 1: Average Weight (WN) and Dimensions (I x w Tile Profile Monier Lifable Atlantis Shake 8 Slate Tile Weight -W (tbt) . length -I (ft) 8.5 Width-w (ft) 1.33 0.833 Tile Profile „Monier !OEMs Atlantis -Shake & Table 2: Ae T bie 3: n Moments due to Grav - M 1110 2" :12" 4 "t12" 5":12" ProEi e 8�ttt8 Direct Bette Deck Direct (: ns Direct Battens eck 1 Deck NIA 8.17 WWI N/A 6,01 Shake & Slate Tile A Hier Lifetile Atlantis s JUL 08,2009 12:04A ABC SUPPLY CO 2 Direct Deck. 6.89 (ft -I 1 6 ". Battens N/A Digit Dealt 5.75 3057518579 NOA No.: 07- 1023.12 ]Expiration Date; 12/16/12 Approval Date: 12/13/07 Page 4 of 7 page 6 Table 4: Attachment Resi ,/ Ce Expressed as a Moment - Mr (ft-tbf) for Nail•On Systems Tile Profile Fastener Type Direct Deck (min 1513" phwood) Direct Deck (min.19132" plywood) Battens *Mier Li stile Atlantis Shake & Slate Tile -1 d Ring Shank Nails 30,9 38.1 N/A 1.10d Smooth or Screw Shank Nail 7.$ 14.0 9,8 18.8 NIA N/A 2-10d Smooth or Screw Shank Naas__ 1 e8 'crew 30.5 30.8 N/A 2 #8 Screw 51,7 61.7 N/A 1 -10d Smooth or Screw Shank Nall (Field Clip) 34.3 24.3 • N/A 1.10d Smooth or Screew Shank Nati (Eave Clip) 19.0 : 19.0 N/A 2 -10d Smooth or Screw Shank Nails (Field Clip) 35.5 35.5 WA 2 -l0d Smooth or Screw Shank Nails Eave CII 31:9 31.9 N/A Table 5: • Attachment Resistance for Two Patty Expressed as a Moment Adhesive Set Systems Tile Application Mr (ft -lbf) Minimum Attachment Resistance Tile Profile Monier Life& Antis Shake & Slate Tile Adhesive' 31.3 " 1 See manufactures component approval or installation uirements. A Flexible .Products Company TtleBand Average weig _Polyfoam Product, irrc. verage weight par parr per patty 13.9 grams. 8 grams. Table 8A: Attachment Resistance for Single Patty Expressed as a Moment Adhesive Set Systems Tile Application - iif (ft -1bf) Mi; .. ,-gum Attachment Resistance Tile Profile Nlon�' r LIMI. Atlantis Shake & Slate Tile PotyProTM 118.9$ �.�40.4 PotyPro'TM . 3 Large Leaf placement of 45 rams of PoI'Pm". j4eraum paddy placement of 24 grams of PolyProwA. Table b@: Attachment Resistance Expressed as a Moment - ...f (it -ibf) for Mortar or Adhesive Set Systc ms Tile Tile Profile Application Monier Lifetlie Atlani�-' is Shake & Slate Tile Mortar Setm 39.0 6 See spec mortar manufacturers Notice of AaeMance attachment 1.esistance JUL 08,2009 12:04A ABC SUPPLY CO I 3057518579 NQA No.: 07- 1023.12 E- 'ration Dates 12/16/12 ., >prove' Date: 72/13107 Page 9 of 7 page 7 5. LABELING All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo, or following statement: "Miami -Dade County Product Con trot Approve,' ". MONIER LTFETILE LLC, ATLANTIS SHARE ANDS! ,.A TF (fl OCA 4? A TON, FL PLANT) LOCATEDUNDEtzN LAI 11':'tr, 6, BUILDING PERMIT ItEQUIREMENTS 6.1 Application for building permit shall be accompanied by copies of the following 6.1.1 This Notice of Acceptance, 6.1.2 Any other documents required by the Building Official or applicable building code i n o r d e r to p r o p e r l y evaluate the instal l a t ion of this system. JUL 08,2009 12:05A ABC SUPPLY CO I 3057518579 NOA No.: 07- 1023.11 Expiration Date: 12116/12 Approval Date: 12/13/07 Page 6 of 7 page 8 • OVERLAY PROFILE DRAWINGS ...■■••••• • ..•••• ***** • MONTER LIFETILE ATLANTIS SHAKE & A " " -RETE ROOF TILE JUL 08,2009 12:05A ABC SUPPLY CO 1 ENO OF THIS Ar'r:r"-.- „INCE. NOA N04 07-1023.12 Expiration Date: 12/16/12 ' Approval Date: 12/13/07 Page 7 of 7 3057518579 page 9 BUILDING AND NEIGHBORHOOD COMPLIANCE DEPARTMENT (BNC) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NOA) Polyfoam Products, Inc. 11715 Boudreaux Road Tomball, TX 77375 MIAMI -DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Stream Room 248 Miami, Florida 33175 -2474 T (786) 315 -2590 F (786) 315 -2593 ..miamidade aov/baildinel SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County BNC - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AM): This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BNC reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product. Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Polypro® A11160 LABMING: Each unit shall bear a permanent label with the manufacturers name or logo, city, state and following statement "Miami -Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in is entirety. INSPECI#ON: A copy of this entire NOA shall be provided to the user by the manufacturer or its distribu ors and shall be available for inspection at the job site at the request of the Building Official. This renews NOA# 06- 0201.02 and consists of pages 1 through 7. The submitted documentation was reviewed by Alex Tiger& IAPPRNED 1 NOA No.: 11- 0124.04 Expiration Date: 05/10/12 Approval Date: 04/14/11 Page 1 of 7 ROOF)ENG COMPONENT APPROVAL: Category: Roofing Sub Category: Roof tile adhesive Materials: Polyurethane SCOPE: This approves Polypro® AH160 as manufactured by Polyfoam Products, Inc. as described in Section 2 of this Notice of Acceptance. For the locations where the design pressure requirements, as determined by applicable building code, does not exceed the design pressure values obtained by calculations in compliance withRoofing Application Standard RAS 127, for use with approved flat, low, and high profile roof tiles system using Polypro® All 160. Where the attachment calculations are done as a moment based system for single patty placement, and as an uplift based system for double patty systems PI ODUC `S MANIIPACTURID BY APPLICANT: Product Dimensions fig Polypro® AH160 N/A TAS 101 Foampra® RTF1000 N/A ProPack®30 & 100 N/A Product Descrintion Two component polyurethane foam adhesive Dispensing Equipment Dispensing Equipment. PRODUCTS MANUFACTURED BY OTHERS: Any Miami -Dade County Product Control Accepted Roof Tile Assembly having.a current NOA which list moment resistance values with the use of Polypro AH160 roof tile adhesive. PHYSICAL PROPERTIES: Property Density Compressive Strength Tensile Strength Water Absorption Moisture Vapor Transmission Dimensional Stability Closed Cell Content Test ASTM D 1622 ASTM D 1621 ASTM D 1623 ASTM D 2127 ASTM E 96 ASTM D 2126 ASTM D 2856 Re_ su 1.6 lbs. /ft.3 18 PS1 Parallel to rise 12 PS1 Perpendicular to rise 28 PSI Parallel to rise 0.08 Lbs./Ft2 3.1 Perm / Inch +0.07'"% Volume Change ® -40° F., 2 weeks +6.0% Volume Change (,a 158 °F.,100% Humidity, 2 weeks 86% Note: The physical properties listed above are presented as typical average values as determined by accepted ASTM test methods and are subject to normal manufacturing variation. NOA No.: 11-0124.04 Expiration Date: 05/10/12 Approval Date: 04114/11 Page 2 of 7 EVIDENCE SUBMITTED: Test Aencv Test Identifier Test Name/Renort DA Center for Applied Engineering #94 -060 TAS 101 04/08/94 257818 -1PA TAS 101 12/16/96 25- 7438 -3 SSTD 11 -93 10/25/95 25- 7438 -4 25- 7438 -7 SSTD 11 -93 11/02/95 25 -7492 SSTD 11 -93 12/12/95 Miles Laboratories NB -589 -631 ASTM D 1623 02/01/94 Polymers Division Ramtech Laboratories, Inc. 9637 -92 ASTM E 108 04/30/93 Southwest Research Institute 01- 6743 -011 ASTM E 108 11/16/94 01- 6739- 0621411 ASTMS 84 01/16/95 Trinity Engineering 7050.02.964 TAS 114 03/14/96 Celotex Corp. Testing Services 528454 -2 -1 TAS 101 10/23/98 528454 -9 -1 528454 -10 -1 520109 -1 TAS 101 1228/98 520109-2 520109 -3 520109-6 520109 -7 520191 -1 TAS 101 03/02/99 520109 -2 -1 LIMITATIONS: 1. Fire classification is not part of this acceptance. Refer to the Prepared Roof Tile Assembly for fire rating. 2. Polypro® A14160 shall solely be used with flat, low, & high tile profiles. 3. Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120. 4. Roof Tile manufactures acquiring acceptance for the use of Polypro® AH160 roof tile adhesive with their tile assemblies shall test in accordance with TAS 101. 5. Roof 'Tile manufactures acquiring acceptance for the use of HANDI -STICK roof tile adhesive with their tile assemblies shall test in accordance with TAS 101 with section 10.4 as modified herein. F4— MS W 2 NOA No.: 11-0124.04 Expiration Date: 05/1 Approval Date: 04/14/11 Page 3of1 INSTALLATION: 1. Polypro® AH 160 may be used with any roof tile assembly having a current NOA that fists uplift resistance values with the use of Polypro® AH160. 2. Polypro® AH160 shall be applied in compliance with the Component Application section and the corresponding Placement Details noted herein. The roof tile assembly's adhesive attachment with the use of Polypro® AH160 shall provide sufficient attachment resistance, expressed as an uplift based system, to meet or exceed the uplift resistance determined in compliance with Miami -Dade County Roofing Application Standards RAS 127. The adhesive attachment data is noted in the roof tile assembly NOA 3. Polypro® AH160 roof tile adhesive and its components shall be installed in accordance with Roofing Application Standard RAS 120, and Polyfoam Products, Inc. Polypro®AH160 Operating Instruction and Maintenance Booklet. 4. Installation must be by a Factory Trained 'Qualified Applicator' approved and licensed by Polyfoam Products, Inc. Polyfoam Products Inc. shall supply a list of approved applicators to the authority having jurisdiction. 5. Calibration of the Foampro® dispensing equipment is required before application of any adhesive. The mix ratio between the "A" component and the "B" component shall be maintained between 1.0- 1.1 5 (A) :1.0 (B). The dispense tuner shall be set to deliver 0.0175 to 0.15 pounds per file as determined at calibration. No other settings shall be approved. 6. Polypro® AH160 shall be applied with Foampro RTF1000 or ProPack® 30 & 100 dispensing equipment only. 7. Polypro® AH160 shall not be exposed permanently to sunlight. 8. Tiles must be adhered in freshly applied adhesive. Tile must be set within 2 to 3 minutes after Polypro® A11160 has been dispensed. 9. Polyprorv) AH160 placement and minimum patty weight shall be in accordance with the Placement Details' herein. Each generic tile profile requires the specific placement noted herein. Table 1: Adhesive Placement For Each Generic Tile Profile TRe Profile Placement Detail Single Paddy Weight Min, (grams) Two Paddy Weight per paddy Min. (warns) Flt Low, Hi Profiles #1 35 N/A High Profile (2 Piece Barrel #1 17 /side on cap and 34/ N/A. Flat, Low, High Profiles #2 24 N/A Flat, Low, High Profiles #3 8 LABELING: All Polypro® AH160 containers shall comply with the Standard Conditions listed herein. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or applicable building code in order t© properly evaluate the installation of this system. NOA Nu 111124.04 Expiration Date: 05/10/12 Approval Date: 04/14/11 Page 4 of 7 ADHESIVE PLAcEMENT DETAIL 1 SINGLE PATTY 9u!fay����ei{dele;�s� � ii; "• ='It��'1 =�� i NOA No.: 11-0124.04 Expiration Date: 05/10112 Approval Date: 04/14/11 Page 5 of 7 ADHESIVE. PLACEMENT DETAIL 2 SINGLE PATTY #OA No.: 114124404 Expiration Date: 95111112 Approval Date: 04/14/11 Page 6 of 7 ADIEESIVE PLACEMENT DETAIL 3 DOUBLE PATTY END OF THIS ACCEPTANCE =171.7r., 4.fel IT) APPROVED NOA No.: 11-0124.04 Expiration Bate: 05/10112 Approval Date: 04/14/11 Page 7 of 7 MIAI 0 CQUtirf BUILDING AND NEIGHBORHOOD COMPLIANCE DEPARTMENT (BNC) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NOA) Polyglass USA Inc. 150 Lyon Drive Fernley, NV 89408 M IAMI -DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175 -2474 T (786) 315 -2590 F (786) 315 -2599 www.miantidatlk..govibuitdme/ SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County BNC - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BNC reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Polyglass Polystick Undertayments LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This renews and revises NOA # 09- 0806.07 and consists of pages 1 through 8. The submitted documentation was reviewed by Alex Tigera. NOA No.: 11- 0601.10 Expiration Date: 09/13/16 Approval Date: 09/15 /11 Page 1 of 8 ROOFING COMPONENT APPROVAL CateEorv: Sub- Cateaorv: Material: Roofing Underlayment SBS , APP Self - Adhering Modified Bitumen PRODUCTS DESCRIPTION: Product Polystick MTS underlayment Manufacturing Location #2 Polystick 1R -Xe underlayment Manufacturing Location #1 &#2 Polystick TU underlayment Manufacturing Location #1 & #2 Polystick TU Plus underlayment (Facer of Membrane with surface printing) Manufacturing Location #1 & #2 Polystick TU P underlayment Manufacturing Location #2 Polystick Tile Pro Mamrfacturing Location #2 Dimensions Roll; 65'8" x 3'3-3/8" 60 mils thick Roll: 65' x 313/8" Or 65'x3' 80 mils thick Roll: 32' 10" x 3'3-3/8" 100 mils thick Roll: 65' x 3'3-3/8" 80 mils thick Roll: 32' 10" x 3'33/8" 130 mils thick Roll: 61' x 3'3 -3/8" 60 mils thick Test Specification TAS 103 TAS 103 and ASTM D 1970 TAS 103 and ASTM D 1970 TAS 103 and ASTM D 1970 TAS 103 and ASTM D 1970 TAS 103 and ASTM D 1970 Product Description A homogeneous, rubberized asphalt waterproofing membrane, glass fiber reinforced with polyolefinic film on the upper surface for use as an underlayment for metal roofing, roof tile, slate tiles and shingle underlayment. A fine granular /sand top surface self - adhering, APP polymer modified, fiberglass reinforced, bituminous sheet material for use as an underlayment in sloped roof assemblies. Designed as an ice & rain shield and as a flat roof tile underlayment. A heavy granuled surface self adhering, APP polymer modified, fiberglass or polyester reinforced, bituminous sheet material for use as an underlayment in sloped roof assemblies. Designed as a a roof tile underlayment. A non- wicking fabric surfaced, self- adhering, APP polymer modified, fiberglass reinforced with a high strength polyester fabric, bituminous sheet material for use an an underlayment in sloped roof assemblies. Designed as a metal roofing and roof tile underlayment. A rubberized asphalt waterproofing membrane, glass - fiber /polyester reinforced, with a granular surface designed for use as a tile roof underlayment. A rubberized asphalt self - adhering, glass - fiber /polyester reinforced waterproofing membrane. Designed as a metal roofing and roof tile underlayment. NOA No.: 11- 0601.10 Expiration Date: 09/13/16 Approval Date: 09/15/11 Page 2 of 8 PRODUCTS DESCRIPTION: Product Polystick Dual Pro Manufacturing Location #2 Dimensions Roll: 61' x 3'3'/8" 60 mils thick MANUFACTURING PLANTS: 1. Hazelton, PA 2. Winter Haven, FL EVIDENCE SUBMITTED: Test Ataxy Exterior Research & Design, LLC Trinity I ERD PRI Asphalt Technologies Momentum Technologies, Inc. Test Specification, ASTM D 1970 Test Identifier 1 1756.04.01 -1 11756.08.01-1 02202.08.05 P5110.08.07 P 10870.09.08-R1 P l 0870.04.09 P33360.06.10 P33370.03.11 P36900.09.1 I PR10 111 1 PUSA - 005 -02-0 I PUSA -018.02 -01 PUSA -035 -02-0 I PUSA -033 -02 -01 PUSA -055 -02 -02 PUSA -083 -02 -01 PUSA -089 -02-01 JX20H7A RX14E8A DX23D8B DX23D8A Product Description A rubberized asphalt self- adhering, glass - fiber /polyester reinforced waterproofing membrane, specific for use as a high temperature underlayment. Designed as a metal roofing. Test Name/Report TAS 103 ASTM D 1970 TAS 103 TAS 103 TAS 103 TAS 103 /ASTM D4798 & G155 ASTM D1970 TAS 103 TAS 103 /ASTM D4798 & G155 ASTM D 4977 ASTM D 4977 ASTM D 2523 TAS 103 ASTM D 1970 TAS 103 TAS 103 TAS 103 /ASTM D4798 & G155 TAS 103 /ASTM D4798 & G155 TAS 103 /ASTM D4798 & G155 TAS 103 /ASTM D4798 & G 155 TAS 103 /ASTM D4798 & G155 Date 04/27/01 08/14/01 08/29/05 08/29/07 12/04108 04/13/09 07/01/10 03/02/11 09/01/11 04/08/02 01/31/02 07/14/03 09/29/06 01/12/06 12/10 /07 06/30/08 07/06/09 04 /01 /08 11/09/09 02/18/10 02/18/10 NOA No.: 11- 0601.10 Expiration Date: 09/13/16 Approval Date: 09/15/11 Page 3 of 8 INSTALLATION PROCEDURES: Deck Type 1; Wood, non - insulated Base Sheet: One or more plies of ASTM D 226 Type 11 or ASTM D 2626. Fastening: Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4" head lap. (for base sheet only) Membrane: Polystick membranes self-adhered. Surfacing: None 1. All nails in the deck shall be carefully checked for protruding heads. Re- fasten any loose decking panels, and sweep the deck thoroughly to remove any dust and debris prior to application. 2. Place the underlayment over metal drip edge in accordance with RAS 111. 3. Place the first course of membrane parallel to the eave, rolling the' membrane to obtain maximum contact. Remove the release film as the membrane is applied. . All side laps shall be a minimum of 3 -''A" and end laps shall be a minimum of 6." Roll the membrane into place after removing the release strip. Vertical strapping of the roof with Polystick is acceptable. Membrane shall be back nailed in accordance with applicable building code. 4. When applying the membrane in the valley, start at the low point and work to the high point, rolling the meinbrane from the center outward in both directions. 5. For ridge applications, center the membrane and roll from the center outward in both directions. 6. Roll or broom the entire membrane surface so as to have full contact with the surface, giving special attention to lap areas. 7. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control Notice of Acceptance. 8. All protrusions or drains shall be initially taped with a 6" piece of underlayment. The flashing tape shall be pressed in place and formed around the protrusion to ensure a tight fit. A second layer of Polystick shall be applied over the underlayment. NOA No.: 13- 0601.10 Expiration Date: 09/13/16 Approval Date: 09 /15/11 Page 4 of 8 GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance. 2. Polystick MTS, TU Plus, and Tile Pro may be used in asphaltic shingles, wood shakes and shingles, non- structural metal roofing, roof tile systems and quarry slate roof assemblies. IR-Xe, TU, and TU P may be used in all the previous assemblies listed except metal roofing. Dual Pro may be used in all the previous assemblies listed except roof tile systems. 3. Deck requirements shall be in compliance with applicable bui ding code. 4. Polyglass Polystick membranes shall be applied to a smooth, clean and dry surface. The deck shall be free of irregularities. 5. Polyglass Polystick membranes and underlayments shall not be adhered directly over a pre - existing roof membrane as a recover system. 6, Polyglass Polystick membranes shall not be left exposed as a temporary roof for longer than the amount of days listed in the table below after application. Polyglass reserves the right to revise or alter product exposure times; not to exceed the preceeding maximum time limitations. Exposure Limitations (days) Polystick MTS MTS IR Xe TU TU Plus TU P Tile Pro Dual Pro Winter Haven, FL. 180 180 180 180 180 180 180 Hazelton, PA. N/A 30 30 180 N/A N/A N/A 7. All products listed herein shall have a quality assurance audit in accordance with the Florida Bui ding Code and Rule 9B -72 of the Florida Administrative Code. 8. In roof tile application, data for the attachment resistance of roof tiles shall be as set forth in the roof tile manufacturer's Notice of Acceptance. Polystick TU and TU Plus may be used in both adhesive set and mechanically fastened roof tile applications. Polystick 1R -Xe, and Tile Pro are limited to mechanically fastened roof tile applications. Polystick MTS is limited to mechanically fastened with battens roof tile applications. Polystick TU P may be used in both adhesive set and mechanically fastened roof tile applications with the exception of mortar set tile applications. 9. The maximum roof slope for use as roof tile underlayment for (direct -to -deck) tile assemblies shall be as follows: (See Table Below) Tile Profile Polystick MTS Polystick IR -Xe Polystick TU, TU Plus, TU P, Tile Pro Flat Tile Prohibited without battens 5:12 No limitation Profiled Tile Prohibited without battens Prohibited No limitation The above slope limitations can be exceeded only by using battens and counter battens in accordance with the Approved Tile System Notice of Acceptance and applicable Florida Building Code requirements. Battens are required for both loading and installation of tiles at all times. 4,PPP,OVED NOA No.: 11- 0601.10 Expiration Date: 89/13/16 Approval Date: 09/15/11 Page 5 of 8 GENERAL LIMITATIONS: (CONTINUED) 10. Care should be taken during the loading procedure to keep foot traffic to a minimum and to avoid dropping of tile directly on the underlayment. Refer to Polyglass' Tile loading detail below for loading procedure for all underlayments except Polystick MTS which shall be loaded onto battens. a1 11. Refer to prepared roofing system Product Control Notice of Acceptance for listed approval of this product with specific prepared roofing products. Polystick MTS,1R -Xe, TU, TU Plus, TU P, Dual Pro and Tile Pro may be used with any approved roof covering Notice of Acceptance listing Polystick MTS, IR -Xe, TU, TU Plus, TU P, Dual Pro and Tile Pro as a component part of an assembly in the Notice of Acceptance. If Polystick MTS, IR -Xe, TU, TU Plus, TU P, Dual Pro and Tile Pro is not listed, a request may be made to the Authority Having Jurisdiction (AHJ) or the Miami -Dade County Product Control Department for approval provided that appropriate documentation is provided to detail compatibility of the products, wind uplift resistance, and fire testing results. LABELING: 1. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city and state of manufacturing facility and the following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade County Product Control Seal as shown below. BUILDING PERMIT REQUIREMENTS: Application for building permit shall be accompanied by copies of the following: 1. This Notice of Acceptance. 2. Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this materials. NOA No.: 11- 0601.10 Expiration Date: 09/13/16 Approval Date: 09/15/11 Page 6 of 8 POLYGLASS GENERAL APPLICATION GUIDELINES FOR POLYSTICK MEMBRANES: 1. Polyglass does accept the direct application of Polystick underlayment membranes to wood decks. Installers are cautioned to refer to applicable local building codes prior to direct deck installation to ensure this is acceptable. Please also refer to applicable Product Data Sheets of the corresponding products. 2. All rolls, with the exception of Polystick TU Plus should be back- nailed in selvage edge seam as per Polyglass Back Nailing Guide. Nails shall be, 11 gauge ring shank type, applied with a minimum 1" metal disk as required in Dade County or simplex type nail as otherwise allowable in other regions, at a minimum rate of 12" o.c. Polystick TU Plus should be back nailed in designated area marked "nail area, area pare clavar" on the face of membrane, with the above stated nails and/or disks. The head lap membrane is to cover the area being back - nailed. (Please refer to applicable local building codes prior to installation.) 3. All seal lap seams (selvage laps) must be rolled with a hand roller to ensure full contact. 4. All fabric over fabric; and granule over granule end laps, shall have a 6" wide, uniform layer of Polyglass Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, Polyglass PG500 MB Flashing Cement, Mule -Hide 241 Premium Modified Flashing Cement, Mule -Hide 251 Premium Wet/Dry Elastomeric Flashing Cement, or Mule -Hide 421 Mod Bit Flashing Adhesive Trowel Grade mastic, applied in between the application of the lap. The use of mastic between the laps does not apply to Polystick MTS. 5. A maximum of 6 tiles per stack are allowed when loading tile on the underlayments. Refer to the Polyglass Tile Loading Guidelines. See General Limitations #9 and # 10. 6. Battens and/or Counter - battens, as required by the tile manufacturers NOA's, must be used on all projects for pitch/slopes of 7"!12" or greater. It is suggested that on pitch/slopes in excess of 6'/ "/12 ", precautions should be taken, such as the use of battens to prevent tile sliding during the loading process. 7. Minimum cure time after membrane installation & before loading of roofing tiles is Forty-Eight (48) Hours. 8. Polystick membranes may not be used in any exposed application such as crickets, exposed valleys, or exposed roof to wall details. 9. Repair of Polystick membranes is to be accomplished by applying Polyglass Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, Polyglass PG500 MB Flashing Cement, Mule -Hide 241 Premium Modified Flashing Cement, Mule -Hide 251 Premium Wet/Dry Elastomeric Flashing Cement, or Mule -Hide 421 Mod Bit Flashing Adhesive Trowel Grade mastic to the area in need of repair, followed by a patch of the Polystick material of like kind should be set and hand rolled in place over the area needing such repair. Patching membrane shall be a minimum of 6 inches in either direction. The repair should be installed in such a way so that water will run parallel to or over the top of all laps of the patch. 10. All self - adhered membranes must be rolled to ensure full contact with approved substrates. Polyglass requires a minimum of 40 Ibs for a weighted roller for the rolling of the field membrane. Hand rollers are acceptable for rolling of patches or small areas of the roof. Brooming may be used where slope prohibits rolling. 11. All approved substrates should be dry, clean and properly prepared, before any application of Polystick membranes commences. An approved substrate technical bulletin can be furnished upon request. It is recommended to refer to applicable building codes prior to installation to verify acceptable substrates. 12. The Polyglass Miami -Dade Notice of Acceptance (NOA) approval for Polystick membranes and PolyProtector UDL can be furnished upon request by our Technical Services Department by calling 1 (800) 894 -4563. NOA No.: 11- 0601.10 Expiration Date: 09/13/16 Approval Date: 09/15/11 Page 7 of 8 13. Questions in regards to the application of Polyglass products should be directed to our Technical Services Department at 1 (800) 894 -4563. 14. Polyglass recommends that applicators follow good roofing practices and applicable procedures as outlined by the National Roofing Contractors Association (NRCA). PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF SPECIFIC APPLICATIONS. LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS AND RECOMMENDATIONS. tla �.ly pt.s.�a41w 6. +�.$l..iJ4l APPRQYEr END OF THIS ACCEPTANCE NOA No.: 11- 0601.10 Expiration Date: 09/13/16 Approval Date: 09/15/11 Page 8of 8 .w• www w..• a.aJAa ...At.J