Loading...
RF-11-1602Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Inspection Number: INSP- 164416 Permit Number: RF -8 -11 -1602 Scheduled Inspection Date: September 19, 2011 Inspector: Bruhn, Norman Owner: BASSIE, JACQUELINE Job Address: 195 NW 91 Street Miami Shores, FL 33138- Project: <NONE> Contractor: MURPHY ROOFS Permit Type: Roof Inspection Type: Final Roof Work Classification: Flat Phone Number Parcel Number 1131010000190 Phone: (305) 892 -1700 Building Department Comments RE ROOF FLAT ROOF BUILT UP MODIFIED BUILT Passed 9,V7'7 Failed Correction Needed Re- Inspection Fee No Additional Inspections can be scheduled until re- inspection fee is paid. Inspector Comments CREATED AS REINSPECTION FOR INSP- 163951. Remove dumpster. NB September 16, 2011 For Inspections please call: (305)762 -4949 Page 37 of 48 RE: Permit # Miami Shores Viiiage Building Department INSPECTION AFFIDAVIT (Print name and circle License Type) License #: 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756=8972 DATE: 7 D f licensed as a (n) Contractor / Engineer/ Architect, FS 468 Building Inspector , I did personally inspect the roof deck nailing and (Date & time) Secondary water barrier work at /Cj iA-Aw '9 i (Complete Job Site Address) Based upon that examination I have determined the installation was done according to the Hurricane Mitigation Retrofit Manual (Based on 553.844 F.S) Signatu State of Florida County of Dade: The undersigned, being the first duly sworn, deposes and says that he /she is the contractor for the above property mentioned. Sworn to and subscribed before me this 0 day o Notary Public, Sate of Florida at Large *General, Building, Residential, or Roofing Contractors or any Individual certified under 468 F.S. to make such an inspection. Include photographs of each plane of the roof with permit # and address # clearly shown marked on the deck for each Inspection Revised on 5/21/2009 11,2\11 PQAAA Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 BUILDING PERMIT APPLICATION FBC 2004 Permit Type (circle): Building Owner's Name (Fee Simple Titleholder) 4/'Q V4 MiehtfAID, Phone # . y SP'$ a 6 51.14 r 2011 Master Permit No. Owner's Address of ®V W 4 / St' City yiIA p I'M 0 "III State A.Z. Zip Tenant/Lessee Name Phone # Job Address (where the work is being done) 11 �` /1) !J Q 1 ST City Miami Shores Village County Miami -Dade Zip FOLIO / PARCEL # Is Building Historically Designated YES NO Contractor's Company Name Contractor's Address City c, e Sc Qualifier Name State Certificate or Registration No. 0-0 9(/ Zip . Phone # ° ` cY/ 'ficate of Competency No. S-03 2 Architect/Engineer's Name (if applicable) Phone # Value of Work For this Permit Type of Work: ❑Addiittiion Describe( Work: �1J t3 e tr " 7�3 Square / Linear Footage Of Work: ❑Alteration ❑New NwAt ❑ Rep. • /Replac ;331/ ❑ Demolition * * * **:x****** ***** **** ** **** * * *** * * **** Fees **:x**** * *** x * *********** * *:x***************** gfo Submittal Fee $ Permit Fee $ Notary $ Training/Education Fee $ Scanning $ Radon $ DPBR $ Bond $ Code Enforcement $ Double Fee $ Structural Review. $ Total Fee Now Due $ 1 ' CCF$ Technology Fee $ Zoning $ CO /CC See Reverse side -+ Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR . CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must' be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged f Signature Signature Owner or Agent The foregoing instrument was acknowledged before me this n The for day of 'r, 20 L, by 4414 /i/10,04(0 , day o who is personally known to me or who has produced "*-80-"- vho is Contractor strument wais ackn ,20! , by known to me or who h As identification and who did take an oath. as identification and wh Sign: Print My Commissio9 CoIm onweafth of Massachusetts My Commiselon Expires Ex ". klatch 14, 2014 ********* ********** k*********************** ** ********* ******************** NOTA ' PUBLIC: Sign: /� I /; MI/ ✓' Print: / e an oath. My Commis& cam APPLICATION APPROVED BY: % ?� (Revised 07/10/07) Plans Examiner Engineer Zoning NOTICE OF COMMENCEMENT A RECORDED COPY M & BE POSTED ON THE 10B SITE AT TIME OF FIRST NEFECTIZN PERMIT-NO. TAX FOLIO NO. STATE OF FLORIDA COUNTY OF MIAMI- DADE: THE UNDERSIGNED hereby gives notice that improvements will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement. 1. Legal description of pro rty an street /address: 1J 111111111111111111111111111111111111111111111 CFN 201180575835 OR 8k '278116 Ps 6529; Ups ) RECORDED 08/2? 2011 10:37 :43 HARVEY RUV'IH, CLERK OF COURT MIACII -FADE COUNTY? FLORIDA LAST PAGE 2. Description of improvement: 3. Owner(s) name and add Interest iri property: Name and address of fee simple titleholder: 4. Contractor's name and address: 5. Surety: (Payment bond required by owner from contractor, Name and address: Amount of bond $ 6. Lender's name and address: OA- if any) GQ- t HEREBY CERTIFY that this is a true Copy o i e urlgir�( fd rAn fk�sHOi;eon day et Fl(� it s� ,f! , A ;,fir WITNESS my hand • , • ' ial Seat. HARVEY ' cam i n and Cow, Courts __ %. �i trii►a�i r 'ments may be served as 7. Persons within the state of Florida designated by Owner upon whom notices o provided by Section 713.13(1)(a)7., Florida Statutes, Name and address: 8. In addition to himself, Owners designates the following person(s) to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b), Florida Statutes. Name and address: 9. Expiration date of this Notice of Commencement: (the expiration date is 1 year from the date of recording unless a different date ecified) Signature &1` Owner Print Owner's Name 44v'/9 Sworn to and subscribed before me this! ! day of Public otary's Name My commission expires: 11301 -39 8/04 PAGES Prepared by Address: *!v c •� - �'S .) n 40-0 JAMES J. HUSSON -COTE Notary Public Common wealth of Massachusetts My Commission Expires March 14, 2014 PERMIT #: — (0Z. IVilami Shores Viiiage Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 RECEIPT DATE: f l Contractor ❑ Owner ❑ Architect Picked up 2 sets of plans and (other) Address: 1. ' S Sfc."C C,czcU.¢sk -nor � From the building department on this date in order to have corrections done to plans And /or get County stamps. I understand that the plans need to be brought back to Miami Shores Village Building Department to continue permitting process. Acknowledged by: PERMIT CLERK INITIAL: RESUBMITTED DATE: 1I PERMIT CLERK INITIAL: Permit No: 11 -1602 Job Name: August 31, 2011. Miami Shores Vivage Building Department Building Critique Sheet 1) Provide a complete product approval. 2) Provide a fire directory listing page. 3) Provide calculations per limitation #7 and RAS 117. 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 Page 1 of 1 Plan review is not complete, when all items above are corrected, we will do a complete plan review. If any sheets are voided, remove them from the plans and replace with new revised sheets and include one set of voided sheets in the re- submittal drawings. Norman Bruhn CBO 305 - 795 -2204 Miami Shores Viiiage Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 OWNERS'S AFFIDAVIT OF EXEMPTION ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR EXISTING SITE - BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES PERSUANT TO SECTION 553.844 F.S. To: Miami Shores Village Building Department 10050 NE 2nd Ave Miami Shores, Fl 33138 Re: Owner's Name: 4471/0 "l '' mNo Date: Property Address: /41 '5— AvL/ q , 1T' 644/ Am/ s v p/l Roofing Permit Number: Dear Building Official: 1 ,,vii /4/ID Aevv certify that I am not required to retrofit the roof to wall connections of my building because: The just valuation for the structure for purpose of ad valorem taxation is less than $300,000.00. Please attach proof of ad valorem taxation. o The building was constructed in compliance with the provisions of the Florida Building Code (FBC) or with the provisions of 1994 edition of the South Florida Building Code (1994 SFBC) Signature 4.vv.,4 ,te /swd Print Name /ph.. c , Cnimrnf D de i%noel .Q The undersigned, being the first duly swam, deposes and says that he/ Sworn to and subscribed before me this 1 day of Notary Public, he is the owner for the above property mentioned. t. • When the just valuation of the structure for purpose of ad valorem taxation is equal to or more than $300,000.00, and the bu SFBC. Then you must provide a building application from a General Contractor for the Roof to Wall connection Hurricane Mitigation. Revised on 5/21/2009 a 1994 , 01)— t Miami Shores Village ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Florida Building Code Edition High- Velocity Hurricane Zone Uniform Penult Applio Master Permit No n Contractor's Name ,(y\ ^ 1 Q' ' \ -s Job Address ) YYC__ / J ,1�t,,J v q APPROVED ZONING DEPT P C A .j EPT BY DATE SpctiOn A�C,anaral Informati SUBJECT TO COMPLIANCE WITH ALL FEDERAL STTATE AND COUNTY RULES AND REGULATIONS Process No. ❑ Mechanically Fastened Tile 0 Mortar /Adhesive Set Tile sphaltic ❑ Metal Panel /Shingles ❑ Wood Shingles /Shakes Shingles ❑ Prescriptive BUR -RAS 160 ROOF TYPE ❑ New Roof Lg7 Reroofin g ❑ Recovering ROOF SYSTEM INFORMATION Low Slope Roof Area (SF) 9 Steep Sloped Roof Area (SF) Section B (Roof plan) ❑ Repair ❑ Maintenance Total (SF) �4` D ilJ Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. a FLORIDA BUILDING CODE — BUILDING ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Florida Building Code Edition 2007 High - Velocity Hurricane Zone Uniform Permit Application Form. Section C (Low Slope Application) Surfacing: Fill in specific roof assembly components and Identify manufacturer Fastener Spacing for Anc, or/Base Sheet Attachment: (If a component is not use .identify, s "NA ") V' Field: " oc La # System Manufacturer. Perimeter " , c (» Product Approval No.: i i,Comer: oc ,) !' ap Design Wind Pres ures, From RAS 128 or Calculations: Number of Fasteners Per Insulation Board: �) � f PmaxT �.r. C P 3• (�:� ws "oc IRows @ " oc Rows @ " oc Pmax1: G max . �/i=ield Perimeter) Max. Design Pressure, from the specific Product 9 Approval system: Deck: Type: Gauge/Thicknes Slope: 2 Anchor/Base Sheet & No. of PIy(s): Anchor/Base Sheet Fastener/Bonding Material: Insulation Base Layer. /`z— P Base Insulation Size and Thickness: 94(—i L-- Base Insulagtionv Fastener/Bonding Material: Top Insulation Layer: Top Insulation Size and Thickness: 5 Top Insulation Fastener/Bonding Material: Base Sheet(s) & No. of PIy(s): poi, 506 Base Sheet Fastener/Bonding Material: Ply Sheet(s) & No. of PIy(s): -_ Ply Sheet Fastener /Bonding Material: Top Ply: Ptr- Top Pty Fastener/Bonding Material: FLORIDA BUILDING CODE — BUILDING Comer 1 Illustrate Components Noted and Details as Applicable: Woodblocking, Gutter, Edge Termination, Stripping, Flashing, Continuous Cleat, Cant Strip, Base Flashing, Counter - Flashing, Coping, Etc. Indicate: Mean Roof Height, Parapet Height, Height of Base Flashing, Component Material, Material Thickness, Fastener Type, Fastener Spacing or Submit MM I� D BUILDING CODE COMPLIANCE OFFICE (BCCO) PRODUCT CONTROL DIVISION MIAMI -DADE COUNTY, FLORIDA METRO -DADE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 MIAMI, FLORIDA 33130 -1563 (305) 375 -2901 FAX (305) 375 -2908 NOTICE OF ACCEPTANCE (NOAH Polyglass USA, Inc. 150 Lyon Drive Fernley, NV 89408 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by Miami -Dade County Product Control Division and accepted by the Board of Rules and Appeals (BORA) to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration 'date stated below. The Miami -Dade County Product Control Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Division that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code and the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Polyglass Self - Adhered Roof System over Wood Decks LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA No. 07- 0822.10 and consists of pages 1 through 20. The submitted documentation was'reviewed by Jorge L. Acebo. M I'DADE C • UNTY APPROVED NOA No.: 08- 0226.06 Expiration Date: 10/11/12 Approval Date: 01/28/09 Page 1 of 20 ROOFING ASSEMBLY APPROVAL Category: Sub - Category: Materials Deck Type: Maximum Design Pressure Roofing Modified Bitumen SBS/APP/TPO Wood -112.5 psf TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Test Product Dimensions Specification Elastobase 65' 2" x 3' 3 -3/8" ASTM D 4601 Elastobase P 5' 2" x 3' 3 -3/8" ASTM D6164 Elastoflex SA V 32' 6" x 3' 3 -3/8" ASTM D 6163 Vent Elastoflex SA V 32' 6" x 3' 3 -3/8" ASTM D 6163 FR Elastoflex SA V 32' 6" x 3' 33/$" ASTM D 6163 EIastoflex SA P 32' 6" x 3' 3 -3/8" ASTM D 6164 FR Elastoflex SA P 32' 6" x 3' 3 -3/8" ASTM D 6164 Polyflex SA P 32' 6" x 3' 3-34" " ASTM D 6222 Polyflex SA P FR 32' 6" x 3' 334" ASTM D 6222 Polyfresko SBS SAP Polyfresko SBS SAP FR Polyfresko APP SAP 32' 6" x 3' 3 -3/8" ASTM D 6164 32' 6" x 3' 3 -3/8" ASTM D 6164 32' 6" x 3' 33/8" ASTM D 6222 Product Description SBS modified asphalt coated fiberglass reinforced base sheet. SBS modified asphalt coated polyester reinforced base sheet. Partially self-adhered, fiberglass reinforced, SBS modified bitumen membrane with a self- adhering back face and a smooth top surface. Self- adhered, fiberglass reinforced, SBS modified bitumen membrane with a self - adhering back face and a smooth top surface. Self- adhered, fiberglass reinforced, SBS modified bitumen membrane with a self- adhering back face and a smooth top surface. Self - adhered, polyester reinforced, SBS modified bitumen membrane with a self - adhering back face and a granule top surface. Self - adhered, fiberglass reinforced, SBS modified bitumen membrane with a self - adhering back face and a granule top surface. Self-adhered, polyester reinforced, APP modified bitumen membrane with a self - adhering back face and a granule top surface. Self-adhered, polyester reinforced, APP modified bitumen membrane with a self - adhering back face and a granule top surface. Self-adhered, fiberglass reinforced, SBS modified bitumen membrane with a self - adhering back face and a granule top surface. Self - adhered, polyester reinforced, SBS modified bitumen membrane with a self - adhering back face and a granule top surface. Self - adhered, polyester reinforced, APP modified bitumen membrane with a self - adhering back face and a granule top surface. NOA No.: 084226.06 Expiration Date: 10/11/12 Approval Date: 01/28/09 Page 2 of 20 Product Polyfresko APP SAP FR PolyKool PolyBianko Cold Process Adhesive PG 100 Asphalt Primer PG350 Mod Bit Adhesive PG400 Plastic Roof Cement PG425 Wet/Dry Roof Cement PG450 Flashing Cement PG500 MB Flashing Cement Polyplus 35 Premium Mod Bit Adhesive Polyplus 45 Premium Flashing Cement PoIyplus 50 Premium MB Flashing Cement Polyplus 55 Premium Modified Flashing Cement APPROVED Dimensions 32'6"x3'334 32' 10" x 3' 3-34" Test Specification ASTM D 6222 ASTM D6222 Type I 32' 10" x 3' 3-34" ASTM D6222 Type I 1, 3, 5, 50, 55 gal. or tube 1, 3, 5, 50, 55 gal, tube or 17 oz. spray can 1, 3, 5, 50, 55 gal. or tube 1, 3, 5, 50, 55 gal. • or tube 1, 3, 5, 50, 55 gal, or tube 1, 3, 5, 50, 55 gal. or tube 1, 3, 5, 50, 55 gal. or tube 1, 3, 5, 50, 55 gal. or tube 1, 3, 5, 50, 55 gal. or tube 1, 3, 5, 50, 55 gal. or tube 1, 3, 5, 50, 55 gal. or tube ASTM D3019 'Type III ASTM D41 ASTM D3019 Type III ASTM D4586 ASTM D3409 ASTM D4586 ASTM D3409 ASTM D4586 ASTM D4586 ASTM D3019 Type I11 ASTM D4586 ASTM D4586 ASTM D4586 Product Description Self - adhered, polyester reinforced, APP modified bitumen membrane with a self - adhering back face and a granule top surface. Self - adhered, polyester reinforced, APP modified bitumen membrane with a self - adhering back face and a white film laminate on the top surface. Self- adhered, polyester reinforced, APP modified bitumen membrane with a self - adhering back face and a white film laminate on the top surface. A fibered cold process adhesive for use with roll or BUR roofmg. A penetrating solution of solvent and a blend of selected asphalts used to promote adhesion. A fibered rubberized adhesive designed for use with modified bitumen membranes. A thick, fibered, rubberized flashing cement for use in dry or damp conditions. A thick, fibered, rubberized flashing cement for use in dry or damp conditions. A thick, fibered, rubberized flashing cement. A thick, fibered, rubberized flashing cement for use with modified bitumen membranes. A fibered rubberized adhesive designed for use with modified bitumen membranes. A thick, fibered, rubberized flashing cement. A thick, fibered, rubberized flashing cement for use with modified bitumen membranes. A mastic compound for use as a roof flashing adhesive. NOA No.: 08- 0226,06 Expiration Date: 10/11/12 Approval Date: 01/28/09 Page 3 of 20 APPROVED INSULATIONS: Product Name Polytherm, POLYTHERM Al Polytherm Composite ACFoam lI ACFoam III High Density Wood Fiberboard Perlite Insulation Type X Gypsum Dens -Deck, Dens -Deck Prime H- Shield H- Shield CG ENRGY -3, JM ISO 3 Fesco Board Multi -Max, Multi -Max FA Securock APPROVED FASTENERS: Fastener Product Number Name 1. Dekfast Fasteners #12, #14 & #15 2. Dekfast Hex Plate 3. Dekfast Lock Plate 4. #12 & #14 Roofgrip 5, Metal Plate 6. Plastic Plate 7. Insul -Fixx HD Fastener TABLE 2 Product Description Polyisocyanurate foam insulation Polyisocyanurate / perlite composite insulation. Polyisocyanurate foam insulation Polyisocyanurate foam insulation Wood fiber insulation board Perlite insulation board Fire resistant rated gypsum. Gypsum insulation board Polyisocyanurate foam insulation Polyisocyanurate/perlite composite insulation Polyisocyanurate foam insulation Expanded mineral fiber Polyisocyanurate foam insulation Fiber reinforced coverboard TABLE 3 Product Description Insulation fastener for wood, steel and concrete decks Galvalume hex stress plate. Manufacturer (With Current NOA) Polyglass USA, Inc. Polyglass USA, Inc. Atlas Energy Products Atlas Energy Products Generic Generic Generic Georgia- Pacific Hunter Panels, LLC Hunter Panels, LLC Johns Manville Corp. Johns Manville Corp. RMax, Inc. USG Manufacturer Dimensions ('With Current NOA) 2'I " x 3 'A" Polypropylene locking 3" x 3'A" plate. Insulation and membrane Various fastener Galvalume AZ50 stress 3" square plate Polyethylene stress' plate 3.2" round Insulation fastener for steel Various and wood decks SFS Intec SFS Intec SFS Inter OMG OMG OMG SFS Inter NOA No.: 08- 0226.06 Expiration Date: 10/11/12 Approval Date: 01/28/09 Page 4 of 20 APPROVED FASTENERS: Fastener Number Product Name • 8. Insul -Fixx S 9. Insul -Fixx P 10. Tru -Fast HD 11. Tru -Fast Plates 12. Tru -Fast Plates APPROVED SURFACING: Product Name PG200 Non - Fibered Roof Coating PG300 Fibered Roof Coating PG600 Non - Fibered Aluminum Roof Coating PG650 Fibered Aluminum Roof Coating P0700 White Reflective Roof Coating PG800 Non - Fibered Asphalt Emulsion Roof Coating TABLE 3 Product Description Galvalume AZ55 stress plate Polyethylene stress plate Insulation fastener for steel and wood decks Galvalume AZ55 steel plate Polyethylene plastic plate TABLE 4 Dimensions 3" round 3" round 3" round 3" round Product Application Description Rate A non fibered asphaltic coating 11/2-2 gal/sq used to add life and rejuvenate existing BUR roofing substrates. An asphalt cutback fibered roof 11/2-2 gal /sq coating. May be applied by brush or spray equipment to rejuvenate aged BUR Non - fibered aluminum roof coating. Fibered aluminum roof coating. A premium white elastomeric acrylic based roof coating (water - based). A polyester fabric may be used for reinforcement with this coating. An asphalt base, un- fibered clay emulsion P0850 Fibered Asphalt An asphalt base, fibered clay Emulsion Roof Coating emulsion Polyplus 65 Premium Fibered aluminum roof coating. Fibered Aluminum Roof Coating Manufacturer (With Current NOA) SFS Intec SFS Intec The Tru -Fast Corp. The Tru -Fast Corp. The Tru -Fast Corp. Specification Manufacturer TAS 140 Polyglass USA, Inc. ASTM D4479 '12-1 gal/sq ASTM D2824 Type I . 11/2-2 gal/sq ASTM D2824 Type III 1 -11/2 gal /sq ASTM D6083 3 gal/sq in two coats 3 gal/sq in two coats 11/2-2 gal/sq Polyglass USA, Inc. Polyglass USA, Inc. Polyglass USA, Inc. Polyglass USA, Inc. ASTM D1227 Polyglass USA, Inc. ASTM D1227 Polyglass USA, Inc. ASTM D2824 Polyglass Type III USA, Inc. NOA No.: 08- 0226.06 Expiration Date: 10/11/12 Approval Date: 01/28/09 Page 5 of 20 APPROVED SURFACING: Product Name Polyp[us 60 Premium Non - Fibered Aluminum Roof Coating Polybrite 70 White Elastomeric Roof Coating Mule -Hide 111 Non - Fibrated Roof Coating Mule -Hide 102 Fibrated Roof Coating Mule -Hide 416 Standard Non - Fibrated Aluminum Roof Coating TABLE 4 Product Description Non - fibered aluminum roof coating. A premium white elastomeric acrylic based roof coating (water - based). A polyester fabric may be used for reinforcement with this coating. Anon- fibrated asphaltic coating used to add life and rejuvenate existing BUR roofing substrates. An asphalt cutback fibered roof coating. May be applied by brush or spray equipment to rejuvenate aged BUR Non - fibrated aluminum roof coating. Mule -Hide 406 Standard Fibrated aluminum roof coating. Fibrated Aluminum Roof Coating Mule -Hide 401 Premium Fibrated Aluminum Roof Coating Mule -Hide 410 Premium Non- Fibrated Aluminum Roof Coating Mule -Hide 311 Emulsion Non - Fibrated Mule -Hide 301 Emulsion Fibrated Gravel Slag Fibrated aluminum roof coating. Non- fibrated aluminum roof coating. An asphalt base, un- fibered clay emulsion An asphalt base, fibered clay emulsion To be installed in a flood coat of approved asphalt at 60 lbs/sq To be installed in a flood coat of approved asphalt at 60 lbs /sq Application Specification Manufacturer Rate 1/2-1 gal/sq ASTM D2824 Polyglass Type I USA, Inc. 1 -11/2 gal/sq ASTM D6083 Polyglass USA, Inc. 1'/2 -2 gal/sq 11/2-2 gal/sq TAS 140 Mule -Hide Products Co., Inc. ASTM D4479 Mule -Hide Products Co., Inc. 1/2-1 gal/sq ASTM D2824 Type I 11/2-2 gal /sq ASTM D2824 Type III 11/2-2 gal /sq ASTM D2824 Type III Mule -Hide Products Co., Inc. Mule -Hide Products Co., Inc. Mule -Hide Products Co., Inc. 1/2-1 gal/sq ASTM D2824 Mule -Hide Type I Products Co., Inc. 3 gal/sq in two coats 3 gal /sq in two coats 400 lbs/sq 300 lbs/sq ASTM D1227 ASTM D1227 N/A N/A Mule -Hide Products Co., Inc. Mule -Hide Products Co., Inc. Generic Generic NOA No.: 08- 0226.06 Expiration Date: 10/11/12 Approval Date: 01/28/09 Page 6 of 20 EVIDENCE SUBMITTED: Test Anne*. Test Name/Report Report No. Date Factory Mutual Research 4470 J.I. 3001334 02.15.00 Corporation 4470 J.I. 3000857 01.12.00 4470 .1.1. 3004091 01.12 :00 Underwriters Laboratory TAS 114 00NK20869 06.08.00 Trinity 1 ERD TAS 114 11751.05.03 05.30.03 TAS 114 11758.08.03 08.11.03 TAS 114 P1738.02.07 02.05.07 TAS 117(B) -ASTM D903 020841.06.04 06.02.04 TAS 114 11757.12.00 -1 12.01.00 TAS 114 11757.04.01 -1 04.27.01 TAS 114 -J P9260.03.08 03.21.08 TAS 114 4 P7860SC.11:08 1130.07 TAS 117(B)- -ASTM D6862 C8500SC.11.07 11.30.07 ASTM D6164 /ASTM D6222 P10490.08.08 08.13.08 ASTM D6164 / ASTM D6222 P10490.10.08 -R1 10.03.08 ASTM D6222 P7400.03.08 -R1 04.04.08 TAS 114(D) — ASTM D1876 P10070.10.08 10.09.08 ASTM D6222 P10490.10.08 -2 1030,08 PRI Asphalt Technologies ASTM D6222 PUSA - 061 -02 -02 01.28.08 ASTM D6222 PUSA- 062 -02 -02 12.04.08 ASTM D6163. PUSA- 064 -02-02 02.27.08 _a WADE ! UNTY APPROVED NOA No.: 08- 0226.06 Expiration Date: 10/11/12 Approval Date: 01/28/09 Page 7 of 20 Deck Type 1I: Deck Description: System Type C(1): Wood, Insulated 19/32" or greater plywood or wood plank, fastened with wood screws at 6" o.c. All layers of insulation are mechanically attached to roof deck. Membrane is subsequently adhered to insulation. All General and System Limitations apply. One or more of the following Insulation Layer ENRGY -3, H- Shield or Polytherm Minimum 1.5" thick Insulation Fasteners (Table 3) 1,7 or 10 Note: All layers of insulation shall be mechanically attached using the faste above. The insulation panels listed are minimum sizes and dimensions; if larger the number of fasteners shall be increased maintaining the same fastener density. Roofing Application Standard RAS 117 for insulation attachment. Fastener Density /ft2 1:133 fts er density listed anels are used, ease ref o Base Sheet: Membrane: Surfacing: Maximum Design Pressure: One or more plies. of Elastoflex SA V or Elastoflex SA V FR self - adhered. . One ply of Polyfresko SBS SAP, Polyfresko SBS SAP FR, Polyfresko APP SAP, Polyfresko APP SAP FR, Elastoflex SA P, Elastoflex SA P FR, Polyflex SA P, PolyBianko, PolyKool or Polyflex SA P FR ..self adhered. (Optional) Install one of the approved surfacing products liste obtain desired coating or required fire classification. �-8 psf; (See General limitation #7.) NOA No.: 08- 0226.06 Expiration Date: 10/11/12 Approval Date: 01/28/09 Page 12 of 20 WOOD DECK SYSTEM LIMITATIONS: 1 A slip sheet is required with Ply 4 and Flex PIyTM 6 when used as a mechanically fastened base or anchor sheet. 2. Minimum ''A" Dens DeckTM or ' /a" Type X gypsum board is acceptable to be installed directly over the wood deck. GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance, refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs. /sq., or mechanically attached using the fastening pattern of the top layer 3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size shall be 4' x 4' maximum. 4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at each sidelap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 12lbs.sq. Note: Spot attached systems shall be limited to a maximum design pressure of -45 psf. 5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F') value of 275 lbf., as tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field - tested, are below 275 Ibf. insulation attachment shall not be acceptable. 6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing, prepared, signed and sealed by a Florida Registered Engineer, Architect, or Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred within this NOA, General Limitation #9 will not be applicable.) 8. All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs shall conform with Roofing Application Standard RAS 1 I 1 and applicable wind load requirements. 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners and corners). (When this limitation is specifically referred within this NOA, General Limitation #7 will not be applicable.) 10.. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9B -72 of the Florida Administrative Code. END OF THIS ACCEPTANCE NOA No.: 07- 1219.09 Expiration Date: 11/04/13 Approval Date: 03/20/08 Page 19 of 19 • TGFU.R14571 - Roofing Systems Page 4 of 8 15. Deck: NC Incline: 1/2 Insulation (Optional): — Polyisocyanurate, perlite, glass fiber or wood fiberboard, any thickness. Base Sheet: — On ply Type G2, hot mopped or mechanically fastened or "ELASTOBASE ", heat fused, hot mopped or mechanically fastened. Membrane: — " ELASTOFLEX S6 G FR ", " POLYFRESKO MOP FR" or "ELASTOSHIELD TS G FR" hot mopped or heat fused. 16. Deck: C -15/32 Incline: 1/2 Base Sheet: — One ply Type G2 or "ELASTOBASE ", mechanically fastened. Ply Sheet — One ply Type G2 (hot mopped or mechanically fastened) or "ELASTOBASE" (hot mopped, heat fused or mechanically fastened). Insulation (Optional): — Polyisocyanurate, perlite, glass fiber, any thickness. Membrane: — " ELASTOFLEX S6 G FR ", " POLYFRESKO MOP FR" or, ELASTOSHIELD TS G FR " hot mopped or heat fused. 17. Deck: C -15/32 Incline: 1/2 Insulation: — Polyisocyanurate (2 in. min), glass fiber (15/16 in. min), perlite / poiyisocyanurate composite, perlite /urethane composite (2 in. min). Base Sheet: — One or more layers "POLYFLEX" (heat fused or mechanically fastened), "ELASTOBASE ", " ELASTOFLEX V ", " ELASTOFLEX V- C" (hot mopped or heat fused) or Type G2 base sheet (hot mopped or mechanically fastened). Ply Sheet (Optional): — One or more layers "POLYFLEX" (heat fused), "ELASTOBASE ", " ELASTOFLEX V ", " ELASTOFLEX V -C" (hot mopped or heat fused) or Type G2 base sheet (hot mopped or mechanically fastened). Membrane: — "DUFLEX G FR ", " POLYFRESKO TORCH FR" or "POLYFLEX G FR" (modified bitumen), heat fused. 18. Deck: C -15/32 Incline: 1/2 Insulation: Polyisocyanurate (2 in. min), glass fiber (15/16 in. min), perlite / polyisocyanurate composite, perlite /urethane composite (2 in. min). Base Sheet: — One or more layers "POLYFLEX" (heat fused or mechanically fastened), "ELASTOBASE ", " ELASTOFLEX V" or Type G2 base sheet (hot mopped or mechanically fastened). Ply Sheet (Optional): — One or more layers "POLYFLEX" (heat fused), "ELASTOBASE ", " ELASTOFLEX V ", " ELASTOFLEX V -C" or Type G2 base sheet (hot mopped or mechanically fastened). Membrane: — " ELASTOFLEX S6 G ", " ELASTOFLEX S6 G -C" or "POLYFRESKO MOP" (modified bitumen), hot mopped. 19. Deck: C -15/32 Incline: 1 Insulation: — 1/4 in. thick G -P Gypsum DensDeck ®, perlite, wood fiber or glass fiber, 1 in., mechanically fastened. Ply Sheet — Type G2, mechanically fastened. Membrane: — "POLYFLEX ", heat welded. Surfacing: — Monsey Products "Endure Aluminum Roof Coating ", "Weather Check" or "Pro-Grade Aluminum Roof Coating ", 1.5 gal /sq; or Brewer "Fortress 5001 Asphalt Emulsion ", applied at 4 gal. /sq., followed by "PolyPlus 60 ", applied at 44-1 gal. /sq.. 20. Deck: C -15/32 Incline: 2 -1/2 Barrier Board: — 1/4 in. (min) G -P Gypsum DensDeck® with all joints staggered 6 in. from the plywood joints. Base Sheet: — Type G2, mechanically fastened. Membrane: — " POLYFLEX G FR" or "POLYFRESKO TORCH FR ", heat fused in place. 21. Deck: C -15/32 Incline: 2 Insulation (Optional): — Polyisocyanurate, perlite, wood fiber or polyisocyanurate /perlite board, any thickness. Barrier Board: — 1/4 in. (min) G -P Gypsum DensDeck ®, mechanically fastened with all joints staggered 6 in. from the plywood joints. Base Sheet: — " ELASTOBASE" (poly /sand), mechanically fastened or "ELASTOFLEX SA V PLUS FR "or "ELASTOFLEX SA V FR BASE VENT" (self adhered). Ply Sheet (Optional): — " ELASTOFLEX SA V PLUS FR" or "ELASTOFLEX SA V FR BASE VENT ", (self adhered). Membrane: — " POLYFLEX SA P FR ", " POLYFRESKO APP SA P FR ", " ELASTOFLEX SA P FR ", " POLYFRESKO SBS SA P FR ", " ELASTOFLEX SA V FR HT", (self adhered) or "POLYFLEX G FR ", " POLYFRESKO TORCH FR ", "DUFLEX G FR ", " ELASTOFLEX S6 G FR ", " POLYFRESKO MOP FR ", " ELASTOSHIELD TS G FR ", heat fused. 22. Deck: C -15/32 Incline: 1/2 Insulation (Optional): — Polyisocyanurate 1.5 in. (min.) with all joints staggered 6 -in. (min.) from the plywood joints. Base Sheet: — Type G2, mechanically fastened followed by "ELASTOBASE ", mechanically fastened. Ply Sheet (Optional): — " ELASTOFLEX SA V PLUS FR" or "ELASTOFLEX SA V PR BASE VENT", (self adhered). Membrane: — " POLYFLEX SA P FR ", " POLYFRESKO APP SA P FR ", " ELASTOFLEX SA P FR ", " POLYFRESKO SBS SA P FR ", or "DUFLEX G FR ", "POLYFLEX G FR ", " ELASTOFLEX S6 G FR ", " POLYFRESKO MOP FR ", " ELASTOSHIELD TS G FR ", heat fused. 23. Deck: NC Incline: 2 http: // database. ul. com /cgi- bin/XYV /template /LISEXT/ 1 FRAME /showpage.html ?name =T... 8/30/2011 SECTION R4402.13 HIGH VELOCITY HURRICANE ZONES — REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS R4402.13.1 Scope. As it pertains to the section, it is the responsibility of roofing contractor to provide the owner with the required roofing permit, and to explain to the owner the content of the section. The provisions of Section R4402 govem the minimum requirements and standards of the industry for roofing system installations. Additionally, the following items should be addressed as part of the agreement between the owner ant the contractor. The owner's initial in the designated space indicates that the item has been explained. 1. �J/' Aesthetics- Workmanship: the workmanship provisions of Section R4402 are for the purpose of providing that the roof system meets the wind resistance and water instruction performance standards. Aesthetics (appearance) are not a consideration with respect to workmanship provisions. Aesthetic issues such as color or architectural appearance, that are not part of a zoning code, should be addressed as part of the agreement between the owner and the contractor. 2. / Renailing wood decks: When replacing roofing, the existing wood roof deck may have to be renailed in accordance with the current provisions of Section R4403. (The roof deck is usually concealed prior to removing the existing roof system). 3. 4` Common roofs: Common roofs are those which have no visible delineation between neighboring units (i.e., townhouses, condominiums, etc.) In buildings with common roofs, the roofing contractor and/or owner should notify the occupants of adjacent units of roofing to be performed. 4. 4 j Exposed Ceiling: Exposed, open beam ceilings are where the underside of the roof decking can be viewed from below. The owner may wish to maintain the architectural appearance; therefore, roofing nail penetration of the underside of the decking may not be acceptable. This provides the option of maintaining the appearance. 5. 4 / Ponding water: The current roof system and /or deck of the building may not drain well and may cause water to pond (accumulate) in low -lying areas of the roof. Pounding can be an indication of structural distress and may require the review of a professional structural engineer. Pounding may shorten the life expectancy and performance of the new roofing system. Pounding conditions may not be evident until the original roofing system is removed. Pounding conditions should be corrected. 6. Overflow scuppers (wall outlets): It is required that rainwater flows off so that the roof is not overloaded from a buildup of water. Perimeter /edge wall or other roof extension may block this discharge if overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in accordance with the requirements of Sections R4402, R4403 and R4413. 7. .� Ventilation: Most roof structures should have some ability to vent natural airflow through the interior of the structure assembly (the building itself). The existing amount of attic ventilation shall not be reduced. It may be beneficial to consider additional venting which can result in ding the service life of the roof. ?tit -7/11 Owner/Agents Signature Date Contactor nature Date Revised on 719/2009 LD ►l