Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
RC-11-666
Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Inspection Number: INSP- 164507 Scheduled Inspection Date: September 20, 2011 Inspector: Bruhn, Norman Owner: GARCIA, LUCIA Job Address: 9426 NW 2 Place Miami Shores, FL 33150- Permit Number: RC -4 -11 -666 Project: <NONE> Contractor: HOME OWNER Permit Type: Residential Construction Inspection Type: Final Building Work Classification: New Phone Number Parcel Number 1131010150070 Building Department Comments ALUMINUM COVER PATIO 18 X 26 1/2 Passed Failed Correction Needed Re- Inspection Fee No Additional Inspections can be scheduled until re- inspection fee is paid. Inspector Comments CREATED AS REINSPECTION FOR INSP - 164325. CREATED AS REINSPECTION FOR INSP - 158467. U channel at wall must have anchors exposed or provide special inspector report. NB C`G September 19, 2011 For Inspections please call: (305)762 -4949 Page 19 of 31 September 16, 2011 US South Engineering & Testing Laboratory, Inc. 14345 Commerce Way, Miami, FL 33016 Phone: 305.558.2588 1 Fax: 305.362.4669 Miami Shores, Fl Building Department Re: FLAT ROOF CONNECTION W/ CONCRETE TIE BEAM (SCREW) INSPECTION Address: 9426 NW 2"d PL. Miami, Florida, PERMIT #: RC 4- 11.666 Dear Sirs: This letter is issued to inform you that a representative of uS. South Engineering & Testing lab. performed a visual Inspection of Existing connection with Tie Beam on Septemberl6, 2011 at the above referenced project. Based on our inspection observation, existing one 1/2" screw @ 12" connected to the concrete tie beam W/ Flat roof.. U.S. South Engineering & Testing lab.. appreciates the opportunity of assisting you in this project. If there is any questions or comments, please do not hesitate to contact our office. Sincerely, U.S. SOUTH Engineering and Testing Lab I.atory, Inc. Ghasem Khavanin, P.E. Florida Registration Number: 41955 Miami Shores Village tanem 'iv-'16,,;(5Arog Building Department ql BUILDING PERMIT APPLICATION FBC 20 X10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 INSPECTION'S PHONE NUMBER: (305) 762.4949 Permit Type: BUILDING OWNER: Name (Fee Simple Titleholder): Address: 9j1.24 /' W ,7 ,00Opee City: 4%x/0% o/4®.ee,, • Tenant/Lessee Name: APR 1.52011 BY: - - -- Permit No. 121C . I 1 ' Master Permit No. Phone #: yj' /IV �7/ J- State: .2.4e// Zip: ti-1437)" Email: c if%.Sp , 2 I/'E' • co xi Phone #: JOB ADDRESS: ,e,6.- tiw t' ' ,4' nL . City: Miami Shores County: Miami Dade Zip: 1,97 Folio/Parcel #: Jij/o /0/6p0 70 Is the Building Historically Designated: Yes NO Flood Zone: CONTRACTOR: Company Name: evAie I' Phone #: Address: 49 /%6 4,1R) 2'" 0#9Z477- City: 0-0- -00/- c5—k'/2e.1% State: .®.41: 9 Zip: ?r7IJ'i7 Qualifier Name: Phone #: State Certification or Registration #: Certificate of Competency #: Contact Phone #: Email Address: DESIGNER Architect/Engineer: Phone #: Value of Work for this Permit: $‘—.Fisg�® 4? Type of Work: °Address Alteration Demolition Description of Work: -- / ,te/' e#6447 4 •�f' 0 Square/Linear Footage of Work �5S'e'� ON w �°Repair/Replace , Z/9/5 o4i ' /f7ifi COLOR THROUGH ROOF TILE IS REQUIRED acknowledged by: Submittal Fee $ ♦ Permit Fee $ /Sad J CCF $ CO /CC $ Scanning Fee $ Radon Fee $ DBPR $ Bond $ Notary $ Training/Education Fee $ Technology Fee $ 1 Double Fee $ Structural Review $ 4, ) o« S� �, ; Q' = �D 180 T OTA -' L FE NOW DUE $ 2591 Q• KJ Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be proved and a reinspection fee will be charged. Owner or Agent The foregoing instrument was acknowledged before me this day of Arfla 1 L.20 (i , by LUC, 1 t-Ar who i wnto me or who has produced As ide, i tification and who did take an oath. i...n. ►UI I I II!N,Jlf „4„i't Sign: �_--,� ?9j/ Print:' pia b✓tarrr� '�� lt'� My Commission Expires: �i.�� ?i; .° , . ;` + k&> it*******de+k*Ne************* *********** ***************** ****** ****** NOTARY PUBLIC: Signature Contractor The foregoing instrument was acknowledged before me this day of , 20 _, by who is personally known to me or who has produced as identification and who did take an oath. NOTARY PUBLIC: Sign: Print: My Commission Expires: APPROVED BY 3 /is Plans Examiner Structural Review (Revised 07 /10 /07)(Revised 06 /l0/2009)(Revised 3/15/09)(rev6/4/10) Zon. Clerk �1 NOTICE OF COMMENCEMENT A RECORDED COPY MUST BE POSTED ON THE JOB SITE AT:TNIE OF FIRST INSPECTION PERMIT NO. STATE OF FLORIDA: COUNTY OF MIAMI -DADE: 111111111111111111111111111111111111111111111 TAX FOLIO NO THE UNDERSICaNED._hereby gives notice that =irnprovernents will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement. 1. Legal • z. portion ofproperty.and reet/add mss:: 1 PN. i *In ll■ CFN 2011R0590491 OR Bk 27813 Ps 009211 (1Ps) RECORDED 0002/2011 11:22 :37 HARVEY RUVTH, CLERK OF COURT HI Atli -DADE Cf3IJHTYr FLORIDA LAST PAGE Space above reserved 101: use of recording offic 2. Description of improvement - .3, Owner(s) naive and ddress: Interest in propertyy: Name and address of fee simple titleholder: 4. ntractor's name, address and ne number. _.- �, mt4rnt s .17. 5. Surety: (Payment bond required by owner from contractor, if any) Name, address and phone number Amount of bend $ S. Lender's name and address 7. Persons`Within the State of Fibrida designated by Owner upon whom notices or other documents may be served asNprovided by Section 713:13(1)0)7., Fferida Statutes, Narne, address and phone nllrmber 8. In addition to himself; Owners designates the • following person(s) to,receive a oopy of the Uenor',s Notice as provided k) Section • 713:13( 1)(6) Florida Statutes: • Narne, address end phone number.: 9. Expiration. date of this Notice of Commencement: • is ECZ itht explratori date to 1 year from trie date of g unre a c ererlt date Is'specif'iec WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPI TION OF PTA NOTICE OF CO ENT ARE CONSIDERED IMPROPER PAYMENTS UNDER: CHAPTER 713 .PART I, SECTION 71313 FLOl A STA ES "11ND CAN RESULT YOl7R PAYING °TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF , ,MMENCEMENT MUST BE RECORDED AND POSTED °ON TIDE JOS StTE`�E T IE FIRST INSPECT IO YOU INTEND TO OBTAIN FINANCING; CONSULT WITH YOUR. LENDER OR AN ATTORNEY. *MG COMMENCING 'WORK OR RECORD, • UR NOTIC ,P• MMENCEMENT. JIM lIWO Prepared Print Name e .• cn uthd >rized Offer /Dtfec>;gr/Partner/Manager • prepared. By Print:Mame TIlle/Offit Tina/ S1i4TE OF t=1 ORID%C``' CO11NTY OF'`PA'" T}re foregoing )hfstrtlitiShf •BY • • day of �� ?�•(��'T ... for fc3ltt iilg die i3f ^tc Mif keno Sfgriature of btai , tl Print Nana: ($EAL) .t •, -mod i�71, VEF IFiCAS'iori PURSUANT TO'SECTION A2.SIS FLORIDA S'I'ATIr'f'Et Under berfalffesr6f-befidk I'ded tare l t 1 have reed`ttie'f&r oing ate'' that the facts stated in it are true, to the best of my knowledge and belief Signatures) -of ()wharfs) or (*holi j°s.Authprized Offs er/Direc orA'artteri By TATE-;OF FLORIDA, COUNTY OF DADE By HEREBY ERTIFY that this is a true copy of the •gr _) led +n j "s office on day of ,AD20 ear. ENO COufy e i� s 811 ro�*:, ?� '44�rrJSA�� •• ` er who nee .above Miami Shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 OWNER BUILDER DISCLOSURE STATEMEN NAM U /9 /NL G f9.ec% DATE: I w l C ADDRESS: Qj-2e ,O) 1449,/ 721,ul trees Do hereby petition the Village of Miami Shores to act as my own contractor pursuant to the laws of the State of Florida, F.S 489.103(7). And I have read and understood the following disclosure statement, which entitles me to work as my own contractor; I further understand that I as the owner must appear in person to complete all applications. State Law requires construction to be done by a licensed contractor. You have applied for a permit under an exception to the law. The exemption allows you, as the owner of your property, to act as your own contractor even though you do not have a license. You must supervise the construction yourself. You may build or improve a one - family or two- family residence. You may also build or improve a commercial building at a cost of $25,000.00 or less (The new form states 75,000). The building must be for your own use and occupancy. It may not be built for sale or lease. If you sell or lease a building you have built yourself within one year after the construction is complete, the law will presume that you built for sale or lease, which is a violation of this exemption. You may not hire an unlicensed person as a contractor. It is your responsibility to make sure the people employed by you have licenses required by state law and by county or municipal licensing ordinances. Any person working on your building who is not licensed must work under your supervision and must be employed by you, which means that you must deduct F.I.C.A and with - holdings tax and provide workers' compensation for that employee, all as prescribed by law. Your construction must comply with all applicable laws, ordinances, buildings codes and zoning regulations. Please read and initial each paragraph. 1. 1 understand that state law requires construction to be done by a licensed contractor and have applied for an owner - builder permit under an exemption from the law. The exemption specifies that I, as the owner of the property listed, may act as my own contractor with certain restrictions even though I do not have a license. 2. I understand that building permits are not required to be signed by a property owner unless he or she is responsible for the construction and is not hiring a licensed contractor to assume responsibility. 3. I understand that, as an owner builder, I am the responsible party of record on a permit. I understand that I may protect myself from potential financial risk by hiring a licensed contractor and having the permit filed in his or her name instead of my own name. I also understand that the contractor is required by law to be licensed in Florida and to list his or license umbers on permits and contracts. Initial 4. I understand that I may build or improve a one family or two- family residence or a farm outbuilding. I may also build or improve a commercial building if the costs do not exceed $75,000. The building or residence must be for my use or occupancy. It may not be built or substantially improved for sale or lease. If a building or residence that I have built or substantially improved myself is sold or leased within 1 year after the construction is complete, the law will presume that I built or ,ibstantially improved it for sale or lease, which violates the exemption. 5. I understand that, as the owner - builder, I must provide direct, onsite supervision of the construction. Initial 6. I understand that I may not hire an unlicensed person to act as my contractor or to supervise persons working on my building or residence. It is my responsibility to ensure that the persons whom I employ have the license required by law and by county or municipal ordinance. 7. I understand that it is frequent practices of unlicensed persons to have the property owner obtain an owner- builder permit that erroneously implies that the property owner is providing his or her own labor and materials. I, as an owner - builder, may be held liable and subjected to serious financial risk for any injuries sustained by an unlicensed person or his or employees while working on my property. My homeowner's insurance may not provide coverage for those injuries. I am willfully acting as an owner - builder and am aware of the limits of my insurance coverage for injuries to workers on my property. Initial 8. I understand that I may not delegate the responsibility for supervising work to be a licensed contractor who is not licenses to perform the work being done. Any person working on my building who is not licensed must work under my direct supervision and must be employed by me, which means that I must comply with laws requiring the withholding of federal income tax and social security contributions under the Federal Insurance Contributions Act (FICA) and must provide workers compensation for the employee. I understand that my failure to follow these may subject to serious financial risk. Initial 9. I agree that, as the party legally and financially responsible for this proposed Construction activity, I will abide by all applicable laws and requirement that govem owner - builders as well as employers. I also understand that the Construction must comply with all applicable laws, ordinances, building codes, and zoning regulations. Initial 10. I understand that I may obtain more information regarding my obligations as an employer from the Internal Revenue Service, the United States Small Business Administration, and the Florida Department of Revenues. I also understand that I may contact the Florida Construction Industry Licensing Board at 850.487.1395 or htto://www.mvfloridalicense.com/dbpdproicilb/index.h Initial 11. I am aware of, and consent to; an owner - builder building permit applied for in my name and understands that I am the party legally and financially responsible for the proposed construction activity at the following address: 12. I agree to notify Miami Shores Village immediately of any additions, deletions, or changes to any of the information that I have provided on this disclosure. Initial Licensed contractors are regulated by laws designed to protect the public. If you contract with a person who does not have a license, the Constr4uction Industry Licensing Board and Department of Business and Professional Regulation may be unable to assist you with any financial loss that you sustain as a result of contractor may be in civil court. It is also important for you to understand that, if an unlicensed contractor or employee of an individual or firm is injured while working on your property, you may be held liable for damages. If you obtain an owner - builder permit and wish to hire a licensed contractor, you will be responsible for verifying whether the contractor is properly licensed and the status of the contractors workers compensation coverage. Before a building permit can be issued, this disclosure statement must be completed and signed by the property owner and returned to the local permitting agency responsible for issuing the permit. A copy of the property owner's driver license, the notarized signature of the property owner, or other type of verification acceptable to the local permitting agency is required when the permit is issued. Was acknowledged before me this 1 3 day of AWZ , 20 c i By L- - (-LCdr A 4, who w personally known to me who has Produced there License or 1 tk- STATE OF (FLORIDA) COUNTY OF (DADE) Miami Shores Viiiage Building Department SURVEY AFFIDAVIT 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 The undersigned Affiant, ivern 44,244E( '4toes hereby attest that (Property owner) The attached survey, performed by %' % #vd c./dea , r'/Pc ati • (Name of surveyor's company) For address: Z‘ 7'..° /11i194,r Aezee A56) Performed on - ` "699 (date of survey) is an accurate representation of the existing conditions and locations of all structures on the property as of this date. The purpose of this Affidavit is to induce Miami Shores Village to issue a building permit for the property without first providing a survey Tess than seven (7) years old old. The Affiant, as property owner, further agrees to remove or obtain permits for any structures which now may exist on the property which are not permitted or which may violate zoning or building code regulations. The Affiant further understands that the existence of any such structures y affect final inspections as applicable to this or other permits. Furth: anAtioir h naught. Pro . erty • er Signature SWORN TO AND SUBSCRIBED before me this Affiant is Revised on 5/22/2009/ Revised on 6/12109 Property Owner Print Name day of '1 i2 lL, 14,3t ( A�`��,��►►nu��c?�'' . IVer e, produced as identification. 4 @r e„, - r r . d.T • ,'�..: lac - -- E.. � � •, = Notary PERMIT #: 11—(0(0"(0 I, LC.t W Go we-u Miami Shores Viiiage Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 7952204 Fax: (305) 756.8972 RECEIPT DATE: g 1 t°1 17W1 ❑ Contractor Owner ❑ rchitect Picked up 2 sets of plans and (other) Address: °14 L From the building department on this date in order to have corrections done to plans And /or get County stamps. I understand that the plans need to be brought back to Miami Shores Village Building Department to continue permitting process. Acknowledged by: PERMIT CLERK INITIAL: RESUBMITTED DATE: 13 PERMIT CLERK INITIAL: ...e.S2& Permit No: 11 -666 Job Name: August 11, 2011 Miami Shores Vivage Building Department Building Critique Sheet 1) Provide structural approval. 2) Provide a floor plan and foundation plan. 3) Provide product approval for roof panels. STOPPED REVIEW. 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 Page 1 of 1 Plan review is not complete, when all items above are corrected, we will do a complete plan review. If any sheets are voided, remove them from the plans and replace with new revised sheets and include one set of voided sheets in the re- submittal drawings. Norman Bruhn CBO 305 - 795 -2204 Wviiami Shores Village Building Department nc I VL�ew 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 Permit No. Ytil 6 C Job Name_C.,0,refa Date/q /LL STRUCTURAL CRITIQUE SHEET Ne. e 1';-- 1 v 6 r 1,10 / 1= a terT a aq h' b p s g 'Lqt t c) b f 121 r4/1 -1 s S• 1 ch h e 1,c, ,e ,fir c /1; `1- ( 5J41A, to cl-"L01-1 0,'.1316c3c try cat Ovt 1 1otof- /mil a 1. Vc Caf- f S/ab e aq e c otic uf 1-1'61,15 a --e �Yt d J-12 e a/ 4 ty-- - /°eY ' 2i $ f efifs ek cb's Co1.S-: r -ee ct i►vfr--134 -ac 51 J -e 17 et de C ` /2 p..0 u c /- ,q I (o fs P -- elf --- hi I //9h/- a 1 -1 1 Planning and Zoning Criteria Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL 33138 -0000 Phone: (305)795 -2204 Fax: (305)756 -8972 Folio Number:1131010150070 Owner's Name: LUCIA GARCIA Job Address: 9426 2 Place Miami Shores, FL 33150- Owner's Phone: Total Square Feet: Total Job Valuation: 496 $ 3,200.00 Contractor(s) HOME OWNER Phone Primary Contractor Yes Planning and Zoning Criteria and Comments Approved: Yes Date Approved: 8/4/2011: Yes Comments: FLAT ROOF CAN NOT EXCEED 300 SQUARE FEET IN AREA. 7/29/11 NEW PLAN OK Permit No: 11 -666 Job Name: July 28, 2011 Miami Shores Viiiage Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 Page 1 of 1 Building Critique Sheet 1) Plans must be signed and sealed by an architect or engineer licensed in Florida. 2) The plans are not at an acceptable scale. Plans at W per foot and details at no Tess than 3/8" per foot. 3) Zoning approval is required. STOPPED REVIEW. Plan review is not complete, when all items above are corrected, we will doa complete plan review. If any sheets are voided, remove them from the plans and replace with new revised sheets and include one set of voided sheets in the re- submittal drawings. Norman Bruhn CBO 305 - 795 -2204 a a 11 js ' -ss 5 Miami Shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 Permit No.; 6, Job Name Date (Ott IA ? /14 /m Aeth STRUCTURAL CRITIQUE SHEET 00 0/raierty Gf Gif" Berl are ,�~o fro be /etbJe —vfe 1/4:4 fltaff / 3 � s m sectroh, (mit$ ). istt 'rte i/ uir,n% load c 4 k u l of f l on" . Planning and Zoning Criteria Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL 33138-0000 Phone: (305)795-2204 Fax: (305)756-8972 Issue Date: Not Issued Folio Num5()013101015)070 Owner's Name: LUCIA GARCIA Job Address: 9426 2 Place Miami Shores, FL 33150- Owner's Phone: Total Square Feet: 496 Total Job Valuation: $ 3,20000 5 Contractor(s) HOME OWNER Phone Primary Contractor Yes Planning nd Zoning Criteria and Comments Approved: Yes Date Approved: 7/29/2011: Yes Comments: FLAT ROOF CAN NOT EXCEED 300 SQUARE FEET IN AREA. 1 7/29/11 NEW PLAN OK Permit No: 11 -666 Job Name: April 19, 2011 Miami Shores Viuiage Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 Page 1 of 1 Building Critique Sheet 1) Plans must be signed and sealed by an architect or engineer licensed in Florida. 2) Zoning approval is required. STOPPED REVIEW. Plan review is not complete, when all items above are corrected, we will doa complete plan review. If any sheets are voided, remove them from the plans and replace with new revised sheets and include one set of voided sheets in the re- submittal drawings. Norman Bruhn CBO 305 - 795 -2204 fA q_ Planning and Zoning Criteria Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL 33138 -0000 Phone: (305)795 -2204 Fax: (305)756 -8972 Permit NO. RC -4 -11 -666 Issue Date: Not Issued Expires:Not Issued Folio Number:1131010150070 Owner's Name: LUCIA GARCIA Job Address: 9426 2 Place Miami Shores, FL 33150- Owner's Phone: Total Square Feet: 496 Total Job Valuation: $ 3,200.00 Planning and Zoning Criteria and Comments Approved: No Date Denied: 4/15/2011 Comments: FLAT ROOF CAN NOT EXCEED 300 SQUARE FEET IN AREA. 04/20/2011 15:59 FAX 1 800 685 7530 DATA SCAN FIELD SERVICES 1001 * * * * * * * * * * * * * * * * * * * ** * ** TX REPORT *** * * * * * * * * * * * * * * * ** * * ** TRANSMISSION OK TX /RX NO 1291 RECIPIENT ADDRESS 919544586833 DESTINATION ID ST. TIME 04/20 15:58 TIME USE 01'00 PAGES SENT 2 RESULT OK Permit No: 11 -666 Job Name: April 19, 2011 Miami Shores Vivage Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 Page 1 of 1 Building Critique Sheet 1) Plans must be signed and sealed by an architect or engineer licensed in Florida. 2) Zoning approval is required. STOPPED REVIEW. Plan review is not complete, when all items above are corrected, we will doa complete plan review. If any sheets are voided, remove them from the plans and replace with new revised sheets and include one set of voided sheets In the re- submittal drawings. Norman Bruhn CBO 305 - 795 -2204 fax q_ MIAMFD�ApE COUNTY BUILDING CODE COMPLIANCE OFFICE (BCCO) PRODUCT CONTROL DIVISION NOTICE OF ACCEPTANCE (NOA) Elite Aluminum Corporation 4650 Lyons Technology Parkway Coconut Creek, Florida 33073 MIAMI -DADE COUNTY, FLORIDA METRO -DADE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 MIAMI, FLORIDA 33130 -1563 (305) 375-2901 FAX (305) 375 -2908 wwwamiamidade.aov SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by Miami -Dade County Product Control Division and accepted by the Board of Rules and Appeals (BORA) to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Division that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: 3" or 6" EPS Roof Panel for Open Structures APPROVAL DOCUMENT: Drawing No. 05 -539 titled " 3" or 6" Roof Panel ", prepared by Thornton Tomasetti, dated November 13, 2006, last revision #0 dated November 13, 2006, sheets I and 2 of 2, signed and sealed by J. W. Knezevich, P.E., bearing the Miami -Dade County Product Control Renewal stamp with the Notice of Acceptance number and the expiration date by the Miami Dade County Product Control Division. MISSILE IMPACT RATING: None LABELING: Fach panel shall bear a permanent label with the manufacturer's name or logo, city, state and the following statement: " Miami Dade County Product Control Approved ", unless otherwise noted herein RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance ofthis product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy ofthis entire NOA small be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA # 08- 0123.03 and consists of this page 1, evidence submitted pages E-1, E-2, E -3 & E-4 as well as approval document mentioned above. The submitted documentation was reviewed by Helmy A. Makar, P.E., M.S. llerG a3jo4,IZoeI NOA No. 08-0919.03 Expiration Date: 02120/2014 Approval Date: 03/04t2009 Page 1 Elite Aluminum Corporation NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 1. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL #95- 1219.04 A. DRAWINGS Title E.P.S. Roof Panel Number 95-681 Sheets 1 through 4 Signature V. John Knezevich, P.E. Date 12/15/95 Revision Date 04 /30/96 B. TESTS Laboratory Construction Testing Corporation Numbers 94-010 and 94-010 S Type PA 202 -94 and 24 Hour Live Load Test on 6 in. sandwich panel Signature Christopher G. Tyson, P.E. Date 01/25/95 and 04/11/95 Laboratory Construction Testing Corporation Numbers 94-013 and 94-012 S Type PA 202 -94 and 24 Hour Live Load Test on 4 in. sandwich panel Signature C. G. Tyson, P.E. Date 01/25/95 and 04/11/95 Laboratory Construction Testing Corporation Number 94-012 Type PA 202 -94 and 24 Hour Live Load Test on 3 in. sandwich panel Signature C. G. Tyson, P.E. Date 01/25/95 Laboratory QC Metallurgical, Inc. Number 4LM-3150 Type Aluminum Tensile Signature Frank Grate, P.E. Date 01/04/95 C. CALCULATIONS Title E.P.S. Roof System Signature V. John Knezevich., P.E. Date 04/13/95 Revision Date 05/09/96 E -1 Makar, P.E., M.S. °duct Control Examiner NOA No. 08-0919.03 Expiration Date: 02/20/2014 Approval Date: 03104/2009 Elite Aluminum Corporation NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 2. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL #99- 0519.05 A. DRAWINGS 1. None. B. TESTS 1. None. C. CALCULATIONS 1. None. D. MATERIAL CERTIFICATIONS 1. None. E. STATEMENTS 1. Letter requesting renewal of NOA No. 95- 1219.04 and stating that the product has not changed, prepared by Elite Aluminum Corporation, dated May 11, 1999, signed by Daniel Cooke. 3. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL # 03- 0109.01 A, DRAWINGS 1. Drawing No. 95-681 titled "E.P.S. Roof Panel", prepared by Knezevich & Associates, Inc., dated December 15, 1995, last revision #2 dated June 19, 2002, sheets 1 through 4 of 4, signed and sealed by V. John Knezevich., P.E. B. TESTS 1. None. C. CALCULATIONS 1. None. D. MATERIAL CERTIFICATIONS 1. None. E. STATEMENTS 1. Letter prepared by Knezevich & Associates, Inc., dated October 10, 2002, signed and sealed by V. John Knezevich., P.E. stating that the product has not changed and the only revised is the general note referring to the Florida Building Code. He ? +'�► �i4Makar, P.E., M.S. Product Control Examiner NOA No. 00-0919.03 Expiration Date: 02/20/2014 Approval Date: 03/04/2009 E -2 ■ Elite Aluminum Corporation NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 4. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL # 06- 1121.05 A. DRAWINGS 1. Drawing No. 05 -539 titled " 3" or 6" Roof Panel '; prepared by Thornton Tomasetti, dated November 13, 2006, last revision #0 dated November 13, 2006, sheets 1 and 2 of 2, signed and sealed by J. W. Knezevich, P.E. B. TESTS 1. None. C. CALCULATIONS 1. Calculation titled 3" & 6" EPS Roof Panels, prepared by Thornton Tomasetti, dated November 08, 2006, sheets 1 through 7 of 7, signed and sealed by John W Knezevich, P.E. D. QUALITY ASSURANCE 1. By Miami Dade County Building Code Compliance Office. E. MATERIAL CERTIFICATION: 1. None. 5. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL #08- 0123.03 A. DRAWINGS 1. None. B. TESTS 1. None. C. CALCULATIONS 1. None. D. QUALITY ASSURANCE - 1. By Miami Dade County Building Code Compliance Office. . MATERIAL CERTIFICATION: 1, None. E -3 4 A. Makar, P.E., M.S. Product Control Examiner NOA No. 08- 0919.03 Expiration Date: 02/20/2014 Approval Date: 03/04/2009 Elite Aluminum Corporation NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 6. NEW EVIDENCE SUBMITTED A. DRAWINGS 1. None. B. TESTS 1. Test Report # HETI -07 -4264, prepared by Hurricane Engineering & Testing Inc., perASTME 72 -05, dated 09/05/2007, signed and sealed by Candido F. Font, P.E. 2. Test Report # HETI-07-4265, prepared by Hurricane Engineering & Testing, Inc., perASTME 72 -05, dated 09/05/2007, signed and sealed by Candido F. Font, P.E. 3. Test Report # .HEI7 07 -4266, prepared by Hurricane Engineering & Testing, Inc., per ASTM E 72 -05, dated 09/05/2007, signed and sealed by Candido F. Font, P.E. 4. Test Report # HETI -07 -4271, prepared by Hurricane Engineering & Testing Inc., perASTME 72 -05, dated 09/05/2007, signed and sealed by Candido F. Font, P.E. 5. Test Report # HETI -07 -4272, prepared by Hurricane Engineering & Testing, Inc., perASTME 72-05, dated 09/05/2007, signed and sealed by Candido F. Font, P.E. 6. Test Report # HETI-07-4411, prepared by Hurricane Engineering & Testing Inc., per ASTME 72 -05, dated 02/20/2008, signed and sealed by Candido F. Font, P.E. 7. Test Report # HET.£ 07 -4412, prepared by Hurricane Engineering & Testing Inc., perASTME 72 -05, dated 02/20/2008, signed and sealed by Candido F. Font, P.E. 8, Test Report # HETI-07-4413, prepared by Hurricane Engineering & Testing, Inc., per ASTME 72 -05, dated 02/20/2008, signed and sealed by Candido F. Font, P.E. 9. Test Report # HETI -07 -4414, prepared by Hurricane Engineering & Testing Inc., per ASTME 72 -05, dated 02/20/2008, signed and sealed by Candido F. Font, P.E. 10. Test Report # HETI-07-4415, prepared by Hurricane Engineering & Testing, Inc., per ASTME 72 -05, dated 02/20/2008, signed and sealed by Candido F. Font, P.E. C. CALCULATIONS 1. None. D. QUALITY ASSURANCE 1. By Miami Dade County Building Code Compliance Office. E. MATERIAL CERTIFICATION: 1. Tensile Test, per ASTME 8-01, test report # HETI- 07 -T743, dated 09/05/2007, signed and sealed by Candido F. Font, P.E. 2. Tensile Test, per ASTME 8 -01, test report # HETI- 07 -T766, dated 02/20/2008, signed and sealed by Candido F. Font, P.E. E -4 y A. Maker, P.E., M.S. Product Control Examiner NOA No. 08-0919.03 Expiration Date: 02/20/2014 Approval Date: 03/04/2009 5 ���� ;;{{ CCaa EE ��qq• � �I� A/ ��ii tB LA <A ILNIMPACT REQUIMENNT 05 �r 2. STRkOSS EASE WHEN 0015€I184 /4 WITH IQ O SS IT taniflif NaNifig ils, cAlLskris, 9 w Y o f IV AS a 3. DIIA Rrj ARA&TY' LAR E M LE cOA A Y 4. TLI pE T MI AFiU M ATN Pp AEDtPOd EM 5. 4HE APOIQROWIN OR ADDITIONS TO THESE APPROVAL DOCUMENTS WILL VOID 6. THiE�APROPvwl*uljl�J MEtVTS.SHALL COMPLY WITH CHAPTER 61815 -23 OP THE 7. T AA ETel' NSIO R VW 5 C�� �y4j�1q�eTTO T�1E E TU CORD OR .A. It3,RREEB NA 9. 517E SP( GIPKTPUCA TRTIO P TH C 10.EPSOMASPITB ROT PANEL roceR QR PROP I2 P THE EPS COMP • ROOFS RWAWA° s BE,ADFD°RESSE AND SHALL BE PERMANENTLY LABELED IN A VISIBLE �� pN g►aew�oaDE . @rB�gg 'nr a yLAPFnotri� }�p'p� M(� yH��Qgy�t� Hp 41. ypA��pl,,-EX'jNCtifil U kiMUTikti g iTALPS E ItIN I• Al allaDNLAY h1AYE A TOU��ryA� gEOpF +0.0566E"yyTU �j EHSCCppSg fSPLMatti-At CIFi�SA{q�1L Ii u. L �p � 12. M PUM+UM TEpNMSISIpgEggRRS�4 pN6e§T(}H�j� F BTLgy� ►{p vpORU TpAINLE8p5�SE to EWITRH - h3 88.8. OP THETFLOR�AC BUILLDIN6 COTDE EC1 EDTIN ACC! QANCE WITH BECTIOk 1. P qe WITM EXPA4DEq POITYS R POAMAPLASTIC CORE %ED OP ALUMINUM 2. PANEL PAtINEIS SHALL BE 0.032" WITH OUT PAINT, ALUMINUM ALLOY 2105-H154. 3. ;,,r yCCOIiSEH/SIH�A•LLL DEp EXPANDED pPOLYSTYRENE WITH THE NOMINAL DENSITY 4. APPLfE1D TO BOT►4$S ANCIID THLEg ORLELMTTi EVIAiLLpASS 2 BY ASHLAND CHEMICAL. 5. T rLC80 rairY 1 /n/taM WALLEBbARDEgR APP(tOVED 18R�INt�TE �MA A B 2. iR.aralli IANNIER 4140 ST C RAL �E EDP CAHITE� TDD S SPECtPI y���{ SS SPpREESSENTEED PRESENTED VALID �ONLY WITH 7110 CONNECTIONS 4. C Aflat RTS�H�A�L�L NOT BE gWC�RPEA�S¢EgD PORWWUILNlftepAQ e0INM�BIN�ATT�IOTM��9:E�g 5. FIE'iro gT AAIHEAD,�OLt Varifpg fililSppT� ril glit ipfTpES�STPryECIFICI EPLECTION 6. hA1�REppPREIS XITA4Mg6 TO BF UgxSED M 617E SPENLCI�I�sCrygCALL LATNTIOINSE6��OpRUT�NEGATIVE/ 7. S� lJTTOTTpp^H11RL,�EEXXouL1IS 5 ��E AH OICA E C P4 R4Cle UmaRACEO LENOT T O. TFi P L sv7TBE <13LON6 E SPEUCI ACUATNS TO THE PLANE OP 9' 940UT pkgASr TOlEpS/ED AS7EP NIPIMANAM CyALA ON7IVEI 10. VNEV SE ADVSRSPC5 AP110Ai�M ALCAHENAHOF71E 11. R�CEE V U 0 E ISO gTSRIpgDAyRABM S A pT EH- B WIDTH m 24.000" OR 4L000" 1 J.W KnezevicI 200E ), 3.000" DdzlaO wetly; B EXPO I`RDD(t¢T KIEV setr '• 2. a °°cOII Ingugh Ike Mold* 129" hl4fiyi Aeeopluk�No of We 00 Dives /13/200! () D !" D$CApit g'3v'1�- 0151.69 ROOF PANELS STRUc um. PROPERTIES x . Y x Y PANELTLNCKNESS 3° : g• , Rix 1.7S x 107 LBS/SI2 x IN4 /FT 5.16 x,107 LBS /IN2 It IN4 /P• Lmmx. 9' - ?" 13'7 10" fix (POS., NEB.) 96E 1.85 - .FT/PT . 1244 I.B - PT /PT V.L 310 LBS/PT 403 LEIS/PT li EI gy 102 SST x 107 1.99111427_4( IN4 /4PT PANEL 91./36 x 10 LBS /IH2 x 1Na /4FT PANEL 9617 LOS - PT /i.FT PANEL 6300 LBS - 147 /4PT PANEL, Y%7 7551 BS /4P 'PANEL ) 960 LOS /4FT PANEL 1. P qe WITM EXPA4DEq POITYS R POAMAPLASTIC CORE %ED OP ALUMINUM 2. PANEL PAtINEIS SHALL BE 0.032" WITH OUT PAINT, ALUMINUM ALLOY 2105-H154. 3. ;,,r yCCOIiSEH/SIH�A•LLL DEp EXPANDED pPOLYSTYRENE WITH THE NOMINAL DENSITY 4. APPLfE1D TO BOT►4$S ANCIID THLEg ORLELMTTi EVIAiLLpASS 2 BY ASHLAND CHEMICAL. 5. T rLC80 rairY 1 /n/taM WALLEBbARDEgR APP(tOVED 18R�INt�TE �MA A B 2. iR.aralli IANNIER 4140 ST C RAL �E EDP CAHITE� TDD S SPECtPI y���{ SS SPpREESSENTEED PRESENTED VALID �ONLY WITH 7110 CONNECTIONS 4. C Aflat RTS�H�A�L�L NOT BE gWC�RPEA�S¢EgD PORWWUILNlftepAQ e0INM�BIN�ATT�IOTM��9:E�g 5. FIE'iro gT AAIHEAD,�OLt Varifpg fililSppT� ril glit ipfTpES�STPryECIFICI EPLECTION 6. hA1�REppPREIS XITA4Mg6 TO BF UgxSED M 617E SPENLCI�I�sCrygCALL LATNTIOINSE6��OpRUT�NEGATIVE/ 7. S� lJTTOTTpp^H11RL,�EEXXouL1IS 5 ��E AH OICA E C P4 R4Cle UmaRACEO LENOT T O. TFi P L sv7TBE <13LON6 E SPEUCI ACUATNS TO THE PLANE OP 9' 940UT pkgASr TOlEpS/ED AS7EP NIPIMANAM CyALA ON7IVEI 10. VNEV SE ADVSRSPC5 AP110Ai�M ALCAHENAHOF71E 11. R�CEE V U 0 E ISO gTSRIpgDAyRABM S A pT EH- B WIDTH m 24.000" OR 4L000" 1 J.W KnezevicI 200E ), 3.000" DdzlaO wetly; B EXPO I`RDD(t¢T KIEV setr '• 2. a °°cOII Ingugh Ike Mold* 129" hl4fiyi Aeeopluk�No of We 00 Dives /13/200! () D !" D$CApit g'3v'1�- 0151.69 DETAB.CORD 0• ;© STRUCTURE BY OTHERS OrCCAL g /4" e fi - 9° CCONNE• SPEcIMC L.OAU RECUT MENTS. INCLUDING DIAPHRAGM FORCES 1/4'�0F DTHRAAUUq�- BOLT12° 0 AAS BEQUIREDITOR RESIST e ' RS AS • IC DIAPHRAGM LO RESIST SITE SPEtIR C LOAD REQUIREMENTS, INCLUDING DIAP AGM FORCES 1/4."0 ThRU..BO T 0 S °'O.C. PRRgOVID "AAp£DOITIINNRA�gL FASTENERS SPECIFIC DIAPHRAGMILOADSE SWAG (2)1/4 "0 THRU -COLT WITH 1'10x0.0 4" ALYA�p. STEEL WASHER D 0.079" NEOPRENE PANELS OR 0 9" MC FOR 6 S PS PANELS 13200 taw:trio* -0 5q �eatz�sx:r�.�rr�. STRUCTURE sY OTHERS 1 /T3/2906 {� 2 x2" ©8 EPS ST14UC BY ofHERS RaOF MNELP WAIJ. HEATER tv4Da>I _ SEE TAKE) C ALE13eo1'- • MECAWind. Version 2.1.0.5 per ASCE 7 -05 Developed by MECA Enterprises, Inc. Copyright 2011 www.mecaenterprises.com Date Company Name Address City State 8/1412011 Project No. 05 : :FLORIDA INTERN. ENG. & TEST Designed By . Description ALUM. FLAT ROOF Customer Name : ISMAEL GARCIA Proj Location : 9426NW 2 PL MIAMI FL : MIAMI : FL Detailed Basic Wind Speed(V) Structural Category Natural Frequency Importance Factor Alpha At Am Cc Epsilon Slope of Roof L: Roof Hor. Width ft Ht: Mean Roof Ht Wind Load Design(Method • 120.00 mph = III • N/A • 1.15 Kd 2) per ASCE 7 -05 = Building = C = No 0.85 Structure Type Exposure Category Flexible Structure Directional Factor = 9.50 Zg = 0.11 Bt = 0.15 Bm = 0.20 1 = 0.20 Zmin = 0.25 : 12 Slope of Roof(Theta) • 50.00 ft D: Roof Length along 900.00 ft 1.00 0.65 500.00 ft 15.00 ft = 1.19 Deg Ridge= 50.00 = 50.00 ft Type of Roof = Monoslope Geist Factor Category I' Rigid'' Structures - Simplified Method Gustl: For Rigid Structures (Nat. Freq.>1 Hz) use 0.85 = 0.85 Gust Factor Category II Rigid Structures - Complete Analysis Zm: lzm: Lzm: Q: Gust2: 0.6 *Ht Cc* (33/Zm) AO. 167- 1 *(Zm /33) ^Epsilon (1/(1 +0.63 *((B +Ht) /Lzm) ^0.63)) ^0.5 0. 925*(( 1+ 1.7 *lzm *3.4 *Q) /(1 +1.7 *3.4 *lzm)) Gust Factor Summary Not a Flexible Structure use the Lessor of Gustl or Gust2 = 30.00 ft 0.2Q = 490..5,6 ft 0.90 - 0.88 - 0.85 Figure 6 -18A Open Building- Monoslope Roof L Load Case A B Load Case A B Cnw 1.200 -1.100 Cnw 1.200 -1.100 Notes: 1) Cnw- windward roof su Notes: 2) Cnl- leeward roof sur Length Along Ridge of Roof Gamma = 0 degrees, Clear Wind Flow Cnl Windward Wind Pres. Leeward Wind Pres. psf psf 0.300 41.775 - 0.100 - 38.294 10.444 -3.481 Gamma = 180 degrees, Clear Wind Flow Cnl Windward Wind Pres. Leeward Wind Pres. psf psf 0.300 - 0.100 41.775 - 38.294 10.444 -3.481 Net Pressures (contributions from top and bottom surfaces for rfaces. Net Pressures (contributions from top and bottom surfaces) for faces. Gamma = 90 degrees, Clear Wind Flow Roof Angle Load Cn Wind Pressure Along Ridge (Theta) Case psf psf <= 50.0 Theta< =45 deg A -0.800 B 0.800 - 27.850 27.850 Notes: 1) Cn- Net Pressures (contributions from top and bottom surfaces). Notes: 2) Plus and minus signs signify pressures acting towards and away from the top roof surface, respectively. MECAWind Version 2.1.0.5 ASCE 7 -05 Developed by MECA Enterprises, Inc. Copyright 2011 www.mecaenterprises.com Project No. . Company Name : Designed By . Address Description . City • Customer Name : State • Pro Location File Location: C: \Program Files \MECAWind \Default.wnd Date : 8/14/2011 Wind Pressure on Components and Cladding Width of Pressure Coefficient Zone "a" = 5 ft Description Width Span Area Zone Cn Cn Max P Min P ft ft ft ^2 Max Min psf psf Enter C &C Desc. 5.00 10.00 50.0 1 1.26 -1.15 43.98 -39.95 Khcc:Comp. & Clad. Table 6 -3 Case 1 = 1.14 Qhcc:.00256 *V ^2 *I *Khcc *Kht *Kd = 40.96 psf PAGE OF LEGAL DESCRIPTION LOT 7, BLOCK 1, ODELL MANOR, ACCORDING TO THE PLAT THEREOF, AS RECORDED IN PLAT BOOK 41, AT PAGE(S) 57, PUBLIC RECORDS OF DADE COUNTY, FLORIDA. 108.70' (CR) 108.80'(M) PROPERTY ADDRESS 9426 NW 2ND PLACE MIAMI SHORES, FL 33150 WI/ 2" RON 6OI'8 Pi NO V. MOCK I r }( 89 °50'43 "(CR) feka ON IL 90 °8'221CR) 90 °09'00 "(CR) 151Y. GARAGE ■ 24.71' INVOICE NUMBER: 4296 DATE OF FIELD WORK: 02/26/1999 CERTIFIED TO ISMAEL AND LUCIA GARCIA WATSON TITLE INSURANCE, INC. FIRST AMERICAN TITLE INSURANCE COMPANY AIB MORTGAGE COMPANY, ITS SUCCESSORS AND /OR ASSIGNS 151Y. IZE5. FLOOD ZONE: X — 120652- 0093 —J H:17Gc LINE 89 °53'38 "(CR) 89 °51'00'(M) 25.00' FNt7 I/ 2" IRON Pre NO)7. (p( y FND #4 RON ROO 149 V. REVISION SCHEDULE: LEGEND: X X X DENOTES CHAIN LANK FENCE UNE DENOTE WOOD FENCE UNE DENOTE ELEVAUON SITE ABBREVIATIONS: AL 4 CF CR DB DE DME e EASE F.F. FIND FPL - ARC LENGTH - CENTER LINE - CALC FROM HELD MEASURE - CALC FROM RECORD INFO - DEED BOOK - DRAINAGE EASEMENT - DRAINAGE MAINTENANCE EASEMENT - CENTRAL ANGLE -EASEMENT - FINISHED FLOOR - FOUND - FLORIDA POWER & LIGHT L - LEGAL M - MEASURED OHC - OVERHEAD POWER CABLE ORB - OFFICIAL RECORDS BOOK P - PLAT PC - POINT OF CURVATURE PCC - POINT OF COMPOUND CURVATURE PCP - PERMANENT CONTROL POINT PK - PARKER KALON NAB. - PROPERTY UNE POB - PONT OF BEGINNING POC - POINT OF COMMENCEMENT PRC - POINT OF REVERSE CURVATURE PT - POINT OF TANGENCY R/W - RIGHT OF WAY RP - RADIUS POINT SBR - SOUTHERN BELL RISER UE - UTILITY EASEMENT W/C • - WITNESS CORNER W/M - WATER METER N 2. 3. 4. 5. 6. 7. 8. OTES: THIS SURVEY IS BASED UPON RECORD INFORMATION AS PROVIDED BY CLIENT. NO SPECIFIC SEARCH OF THE PUBUC RECORD HAS BEEN MADE BY THIS OFFICE. UNDERGROUND IMPROVEMENTS HAVE NOT BEEN LOCATED EXCEPT AS SPECIFICALLY SHOWN. ELEVATIONS ARE BASED UPON NATIONAL GEODETIC VERTICAL DATUM 1929 (N.G.V.D. 1929). FENCE TIES ARE TO CENTERUNE OF FENCE IN SOME CASES, GRAPHIC REPRESENTATIONS HAVE BEEN EXAGGERATED TO MORE CLEARLY ILLUSTRATE MEASURED RELATIONSHIPS - DIMENSIONS SHALL HAVE PRECEDENCE OVER SCALED POSMONS. ALL DIMENSIONS SHOWN ARE FIELD MEASURED AND CORRESPOND TO RECORD INFORMATION UNLESS SPECIFCALLY NOTED OTHERWISE. CORNERS SHOWN AS 1ET ARE IDENTIFIED WITH A CAP MARKED LB (UCENSED BUSINESS) # 6799 ELEVATIONS SHOWN - IF APPLICABLE - ARE BASED UPON BENCH MARK: ELEVATION = N.G.V.D.1929 SURVEYOR'S CERTIFICATION: I HEREBY CERTIFY THAT THIS BOUNDARY SURVEY MEETS THE MINIMUM TECHNICAL STANDARDS FOR SURVEYS. AS SET FORTH BY THE FLORIDA BOARD OF SURVEY D =' - IN CHAPTER 61 G17-6 OF THE FLORIDA ADMINISTRATIVE CODE. PJdI U r TO SEC :2.J7. FLORIDA STATUTES. SIGNED: i DATE: ANDREW SNYDER P SURVEYOR AND MAPPER FLORIDA REGISTRATION NO. 5639 (NOT VALID WRnOUT THE SNGNATUkE AND THE ORIGINAL RAISED SEAL OF THE FLORIDA LI' ENSED'SURVTYYORAND MAPPER SHOWN ABOVE) LANDTECH SURVEYING & INSPECTIONS Provid'mg Land Surveying & Home Inspection Services to South Rorida 9,1QaeunaGG�. tolion.! 1500 NW 62ND STREET BUTTE 51 1 FORT LAUDERDALE, FLORIDA 33309 (954) 776-6766 - FAX: (954) 776-4660