Loading...
EL-11-1546Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Inspection Number: INSP - 164569 Scheduled Inspection Date: September 20, 2011 Inspector: Devaney, Michael Owner: MARDINI, MARUAN Permit Number: EL -8 -11 -1546 Job Address: 26 NE 109 Street Miami Shores, FL Project: <NONE> Contractor: LONGMAN ELECTRIC INC Permit Type: Electrical - Residential Inspection Type: Final Work Classification: Alteration Phone Number Parcel Number 1121360110380 Phone: (305)758 -1211 Building Department Comments INSTALL ELECTRIC CHANGE UNDERGROUND Passed Failed Correction Needed Re- Inspection Fee No Additional Inspections can be scheduled until re- inspection fee is paid. Inspector Comments °/7/ September 19, 2011 For Inspections please call: (305)762 -4949 Page 30 of 31 Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 't Tel: (305) 795.2204 Fax: (305) 756.8972 �V✓" INSPECTION'S PHONE NUMBER: (305) 762.4949 BUILDING Permit No Il SkP PERMIT APPLICATION Master Permit No. FBC 20 AUG 2 2 2011 BYO .e ....................o Permit Type: Electrical ^ OWNER: Name (Fee Simple Titleholder): J 4 V /� /9-72.-4 Y Phone#: 7a g'3 /erd Address: A/E /67 % /h• -5."7-!2 �E7 City: / #9-?7T ( ./l Cr7Z State: zip: 3 3 / C` / Tenant/Lessee Name: Phone#: Finail• JOB ADDRESS: 2• /V %r7 92' Sz /e' E City: Miami Shores County: Miami Dade Zip: Z 3' / C Folio/Parcel #: // - Z /3 — // — ® s'' 0 Is the Building Historically Designated: Yes NO � Flood Zone: CONTRACTOR: Company Name: 1 r3,ot//61h4-ns �1r c/ L Phone#: 3o5 -751 01 l/ Address; , II 11/ J 74 _571k-eel- City: /hi e,41s 5 4 b State: Zip: 33 )34' Qualifier Name: /YLl t q�sl ��/ �, 9l Phone#: 365-- 75 r A// State Certification or Registration #: C- l ?, C c .3 7/ 3 Certificate of Competency #: Contact Phone#: '7256 97 a )3 G / Email Address: DESIGNER: Architect/Engineer: Phone#: Value of Work for this Permit: $ %L�CU . o U Square/Linear Footage of Work: Type of Work; GAddress AlteratJion l7New ORepair/Replace ODemolition Description of Work: 777/j761. / £/ l 711't C__ 1-e, Jz'Cc *************************************** F************* * * * * * * * * * * * * *** * * * *** * * * * * * * * ** Submittal Fee $ Permit Fee $ 1/-6 2-,' ' '� CCF $ CO /CC $ Scanning Fee $ Radon Fee $ DBPR $ Bond $ Notary $ Training/Education Fee $ Technology Fee $ Double Fee $ Structural Review $ TOTAL FEE NOW DUE $ I Bonding Company's Name (if applicable) Bonding Company's Address City State ZIP Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC OWNER'S AkFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged Signature .//) er or Agent The foregoing instrument was acknowledged before me this day of /4.0605 , 204_, by MVO N,QO who is ylcnnslvmto me or who has produced As identification and who did take an oath. NOTARY PUBLIC: Sign: 9" -N (AU- Print: DAu ii - i eet6 My Commission Expires/0 /I h (zoil p Notary Public State of Florida � David Treece e My Commission DD933744 ,or 0.o1° Expires 10/18/2013 Signature Contractor The foregoing instrument was acknowledged before me this,... day of 41/5 t,'S 7' , 20 IL,, by who ispersonally known to me or who has produced as identification and who did take an oath. NOTARY PUBLIC: Sign: Print: My Commission Expires: *********“************ a********* * ***** **************e **e ** * * ** *** ***** * *** ****eve * *a****ee+s************* APPROVED BY �' f 5% A k Plans Examiner Zoning Structural Review (Revised 07/10107)(Revised 06 /10/2009)(Revised 3/15/09) Clerk David Hardy 26 NE 109th Street Miami Shores, FL 33161 METER Main 200 AMP 3# 2/0 THHN 1 1/2 Sch. 80 PVC 200 AMP Nema 3R PANEL 1 Phase 120 / 240 12 CKT 4— #4 Ground ROD 8'X5/8 4— FPL 2" Sch. 80 PVC ROD 8' X 518 Cold Water SUI1JFCT TO COMPLIANCE WITH ALL FEDERAL S1 AIT AND CM INTY RULES AND REGULATIONS 26 NE 109th Street Miami Shores, FL 33161 David Hardy Panel Schedule 1.) A/C Handler 3.) A/C Handler 5.) A/C Compressor 7.) A/C Compressor 9.) lighting 11.) lighting 13.) Kitchen App. 15.) Kitchen App. 17.) lighting 19.) Lighting 21.) Pump 23.) Pump Longman Electric EC 13003713 60 Amp 60 Amp 40 Amp 40 Amp 20 Amp 20 Amp 20 Amp 20 Amp 15 Amp 20 Amp 20 Amp 20 Amp 6.) Dryer 30 Amp 8.) Dryer 30 Amp 10.) Lighting 15 Amp 12.) Lighting 15 Amp 14.) Lighting 15 Amp 16.) Lighting 15 Amp 18.) Lighting 20 Amp 20.) Refrig 20 Amp 26 NE 109 Street Miami Shores, FL 33161 David Hardy LOAD CALCULATION 1645 sqft x 3VA 4935 Small Appliance 3000 Laundry 1500 Dishwasher 1200 Water heater 4500 Disposal 1000 Dryer 5000 washer 1500 Pump 1200 19335 -10000 9335 10000 x 40% 3734.00 3734.00 13734 10000 air conditioning 23734 full VA 23734 / 240 0 volts= 98.89167 amperage David Hardy 26 NE 109th Street Miami Shores, FL 33161 METER Main 200 AMP 3# 2/0 THHN 1 1/2 Sch. 80 PVC 200 AMP Nema 3R PANEL 1 Phase 120 / 240 12 CKT 4— #4 Ground 4- FPL 2" Sch. 80 PVC ROD 8' X 5/8 ROD 8' X 5/8 Cold Water Miami Shores Village APPROVED ZONING DEPT BLDG DEPT BY v ZPV DATE 7Z` ;L1f3JFCT TO COMPLIANCE WITH ALL FEDERAL T A TV AND COUNTY RULES AND REGULATIONS 26 iJE 109th Street Miami Shores FL 3316.i David Hardy Panel Schedule 1.) A/C Handler 3.) A/C Handler 5.) NC Compressor 7.) NC Compressor 9.) lighting 11.) lighting 13.) Kitchen App. 15.) Kitchen App. 17.) lighting 19.) Lighting 21.) Pump 23.) Pump Longman Electric EC 13003713 60 Amp 60 Amp 40 Amp 40 Amp 20 Amp 20 Amp 20 Amp 20 Amp 15 Amp 20 Amp 20 Amp 20 Amp 6.) Dryer 30 Amp 8.) Dryer 30 Amp 10.) Lighting 15 Amp 12.) Lighting 15 Amp 14.) Lighting 15 Amp 16.) Lighting 15 Amp 18.) Lighting 20 Amp 20.) Refrig 20 Amp 26 NE 109 Street Miami Shores, FL 33161 David Hardy LOAD CALCULATION 1645 sqft x 3VA 4935 Small Appliance 3000 Laundry 1500 Dishwasher 1200 Water heater 4500 Disposal 1000 Dryer 5000 washer 1500 Pump 1200 19335 -10000 9335 10000 x 40% 3734.00 3734.00 13734 10000 air conditioning 23734 full VA 23734 / 240 0 volts= 98.89167 amperage