Loading...
WS-11-559Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Inspection Number: INSP- 157788 Permit Number: WS -3 -11 -559 Scheduled Inspection Date: August 29, 2011 Inspector: Bruhn, Norman Owner: MONTERO, ANGELICA Job Address: 9338 NW 2 Avenue Miami Shores, FL 33150- Project: <NONE> Contractor: HOME OWNER Permit Type: Windows /Shutters Inspection Type: Final Work Classification: Window /Door Replacement Phone Number Parcel Number 1131010150280 Building Department Comments REPLACEMENT OF 9 WINDOWS AND 1 DOOR Failed Correction Needed Re- Inspection Fee No Additional Inspections can be scheduled until re- inspection fee is paid. Inspector Comments August 26, 2011 For Inspections please call: (305)762 -4949 Page 6 of 41 Project Address Miami Shores Village 10050 N.E. 2nd Avenue NW Miami Shores, FL 33138 -0000 Phone: (305)795 -2204 9338 NW 2 Avenue Miami Shores, FL 33150- Owner Information Parcel Number Applicant Address 1131010150280 Block: Lot: BEATRICE SHADLOFF Phone CeII ANGELICA MONTERO 9338 NW 2 Avenue MIAMI SHORES FL 33150- i 9338 NW 2 Avenue MIAMI SHORES FL 33150- Contractor(s) HOME OWNER Phone CeII Phone Valuation: Total Sq Feet: $ 4,000.00 0 1 Type of Work: WINDOWS & DOORS No of Openings: 10 Additional Info: Classification: Residential Scanning: 6 , , Fees Due CCF DBPR Fee DCA Fee Education Surcharge Permit Fee Scanning Fee Technology Fee Total: Amount $2.40 $3.00 $3.00 $0.80 $200.00 $18.00 $3.20 $230.40 , Pay Date Pay Type Invoice # WS -3 -11 -40488 04/08/2011 Check #: 266 03/31/2011 Check #: 260 Amt Paid Amt Due $ 180.40 $ 50.00 $ 50.00 $ 0.00 Available Inspections: Inspection Type: Window Door Attachment Final Shutters Final Shutter Attachment In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Futhermore, I authorize the above -named contractor to do the work stated. April 08, 2011 Authorized Signature: Owner / Applicant / Contractor / Agent Building Department Copy Date April 08, 2011 1 d Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795,2204 Fax: (305) 756.8972 INSPECTION'S PHONE NUMBER: (305) 762.4949 BUILDING PERMIT APPLICATION FBC 20 I1 9. t Permit No. Master Permit No. Permit Type: BUILDING ROOFING . . Owner's Name (Fee Simple Titleholder) P %3 &i ■\C A -- 101J\--C (0 Phone # SAO\ 3b2— fi30�P Owner's Address Q 3'J FS t.) W . '2.tJC Ae , City LC S VW-ES State -FL Zip . 33 \ S 0 Tenant/Lessee Name Phone # Email LL Le ca e.144 t.10,-,' to (33 . C Job Address (where the work is being done) City Miami Shores Village County Miami -Dade Zip FOLIO / PARCEL Is Building Historically Designated YES NO Flood Zone Contractor's Company Name OU.)N'C. C Contractor's Address City Qualifier Name Phone # State Certificate or Registration No Certificate of Competency No, Contact Phone E -mail Phone # State Zip Architect/Engineer's Name (if applicable) Phone # Value of Work For this Permit $ '� Square / Linear Footage Of Work: Type of Work: ❑Addition ['Alteration An❑New ❑ Repair/Replace ❑ Demolition Describe Work: Rip. �Q Cf ef- feu?;- ! l Apt tQct too& 4TUOC3* * * * *. *: ar * * * * * * * * * *. * * * * * * * ** * *** * * * * * ** Fees***** * * * * * * * * * * * * * * * ** * ** * * ** * ** * * ** A�. 11�� O Q6 Submittal Fee $ W *00 Permit Fee $ CCF $ CO /CC $ Notary $ Training/Education Fee .$ Technology Fee $ Scanning $ Radon $ DPBR $ Bond $ Double Fee $ Violation date: Structural Review. $ _ Total Fee Now Due $ , yO See Reverse side --� Bonding Company's Name (if applicable) Bonding Company's Address City Mortgage e*der's Name (if app; Mortgage Lender's Address City State Zip able) State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation ] commenced prior to the issuance of a permit and that all work will he performed to meet the standards of all laws regulatin , construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC,...: OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. AltisTING TO ON VNER. YOUR FAILURE TO RECORD A NOTICE 0 COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY, IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCE LENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person' whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the, job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature Sign Owner or Agent The foregoing instrument was acknowledged before me this day of , 20 t by A3 1-1-1 CA' I' i't 's? he is personally known`to me or moo has produced f L M identification and who did take an oath. NOTARY PUBLIC: Contractor The foregoing instrument was acknowledged li day of ,20 ,by who is personally known to Inc . or who has produced as identification and who did take an oath. NOTARY PUBLIC: Print: Print: My Commission Expires: APPROVED Jay-,': Plans Examiner Engineer (Revised 07/10 Miami Shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 OWNER BUILDER DISCLOSURE STATEMENT NAME: I / C GG M DATE: ADDRESS: 93-375 %VV'J 9s. W Do hereby petition the Village of Miami Shores to act as my own contractor pursuant to the laws of the State of Florida, F.S 489.103(7). And I have read and understood the following disclosure statement, which entitles me to work as my own contractor; I further understand that I as the owner must appear in person to complete all applications. State Law requires construction to be done by a licensed contractor. You have applied for a permit under an exception to the law. The exemption allows you, as the owner of your property, to act as your own contractor even though you do not have a license. You must supervise the construction yourself. You may build or improve a one - family or two- family residence. You may also build or improve a commercial building at a cost of $25,000.00 or less (The new form states 75,000). The building must be for your own use and occupancy. It may not be built for sale or lease. If you sell or lease a building you have built yourself within one year after the construction is complete, the law will presume that you built for sale or lease, which is a violation of this exemption. You may not hire an unlicensed person as a contractor. It is your responsibility to make sure the people employed by you have licenses required by state law and by county or municipal licensing ordinances. Any person working on your building who is not licensed must work under your supervision and must be employed by you, which means that you must deduct F,I.C.A and with- holdings tax and provide workers' compensation for that employee, all as prescribed by law. Your construction must comply with all applicable laws, ordinances, buildings codes and zoning regulations. 3l JI Please read and initial each paragraph. 1. I understand that state law requires construction to be done by a licensed contractor and have applied for an owner- builder permit under an exemption from the law. The exemption specifies that I, as the owner of the properly listed, may act as my own contractor with certain restrictions even though I do not have a license. Initial ' 7L 2. I understand that building permits are not required to be signed by a property owner unless he or she is responsible for the construction and is not hiring a licensed contractor to assume responsibility. Initial ''`"" 7L- 3. I understand that, as an owner builder, I am the responsible party of record on a permit. I understand that I may protect myself from potential financial risk by hiring a licensed contractor and having the permit filed in his or her name instead of my own name. I also understand that the contractor is required by law to be licensed in Florida and to list his or license numbers on permits and contracts. Initial 4. I understand that I may build or improve a one family or two- family residence or a farm outbuilding. I may also build or improve a commercial building if the costs do not exceed $75,000. The building or residence must be for my use or occupancy. It may not be built or substantially improved for sale or lease. If a building or residence that I have built or substantially improved myself is sold or leased within 1 year after the construction is complete, the law will presume that I built or substantially improved it for sale or lease, which violates the exemption. 74--. Initial 5. I understand that, as the owner - builder, I must provide direct, onsite supervision of the construction. Initial 6. I understand that I may not hire an unlicensed person to act as my contractor or to supervise persons working on my building or residence. It is my responsibility to ensure that the persons whom I employ have the license required by law and by county or municipal ordinance. Initial 7. I understand that it is frequent practices of unlicensed persons to have the property owner obtain an owner - builder permit that erroneously implies that the property owner is providing his or her own labor and materials. I, as an owner- builder, may be held liable and subjected to serious financial risk for any injuries sustained by an unlicensed person or his or employees while working on my property. My homeowner's insurance may not provide coverage for those injuries. I am willfully acting as an owner - builder and am aware of the limits of my insurance coverage for injuries to workers on my property. Initial B. I understand that I may not delegate the responsibility for supervising work to be a licensed contractor who is not licenses to perform the work being done. Any person working on my building who is not licensed must work under my direct supervision and must be employed by me, which means that I must comply with laws requiring the withholding of federal income tax and social security contributions under the Federal Insurance Contributions Act (FICA) and must provide workers compensation for the employee. I understand that my failure to follow these may subject to serious financial risk: Initial /74r 9. I agree that, as the party legally and financially responsible for this proposed Construction activity, I will abide by all applicable laws and requirement that govern owner - builders as well as employers. I also understand that the Construction must comply with all applicable laws, ordinances, building codes, and zoning regulations. Initial 4-'1- 10. I understand that I may obtain more information regarding my obligations as an employer from the Internal Revenue Service, the United States Small Business Administration, and the Florida Department of Revenues. I also understand that I may contact the Florida Construction Industry Licensing Board at 850.487.1395 or http: / /www.myfloridalicense.com /dbpr /pro /cilb /index.html Initial 7C 11. I am aware of, and consent to; an owner - builder building permit applied for in my name and understands that I am the party legally and financially responsible for the proposed construction activity at the following address: Initial74>4 12. I agree to notify Miami Shores Village immediately of any additions, deletions, or changes to any of the information that I have provided on this disclosure. Initial Licensed contractors are regulated by laws designed to protect the public. If you contract with a person who does not have a license, the Constr4uction Industry Licensing Board and Department of Business and Professional Regulation may be unable to assist you with any financial loss that you sustain as a result of contractor may be in civil court. It is also important for you to understand that, if an unlicensed contractor or employee of an individual or firm is injured while working on your property, you may be held liable for damages. If you obtain an owner- builder permit and wish to hire a licensed contractor, you will be responsible for verifying whether the contractor is properly licensed and the status of the contractors workers compensation coverage. Before a building permit can be issued, this disclosure statement must be completed and signed by the property owner and returned to the local permitting agency responsible for issuing the permit. A copy of the property owner's driver license, the notarized signature of the property owner, or other type of verification acceptable to the local permitting agency is required when the permit is issued. Was acknowledged before me this ck"..‘ day of ,20 lb By N,kit.1.-kc-4-. who was personally known to me or who has Produced there License or OWNER as � 1entifcation. • ,ot �`0�1901,7/ ei < /// a71iIS s \`N' �����lll • GISELA REY, P.E. 14921 SW 30th TER Miami, Florida 33185 Phone: 305 229 -8374 Fax 305 226 -6904 By GR Date 2/1/11 Sheet 2 Of 4 ANGELICA MONTERO RESIDENCE 9338 NW 2 AVE MIAMI , FL 33150 WIND LOAD CALCULATION FOR WINDOWS AND DOORS Miami Shores Ville • e APPROVED ZONING DEPT BLDG DEPT DATE stAIACT ToCOMPUAN STATE AND COUNTY RULES ANDREDULATtoms f• 1 MAk31N11 • .. • •. .. • • .• .• • • • • • • • GISELA REY, PE STRUCTURAL ENGINEER FL, P.E. No. 66366 • GISELA REY, P.E. 14921 SW 30th TER Miami, Florida 33185 Phone: 305 229 -8374 Fax 305 226 -6904 By GR Date 2/1/11 Sheet 2 Of 4 Project: ANGELICA MONTERO RESIDENCE WIND LOAD DATA ONE STORY BUILDING WIND LOAD AS PER ASCE 7/05 FOR MEAN ROOF ELEVATION LESS THAN 60 FEET B = MINIMUM WIDTH (FT) = 25.50 H = MEAN ROOF ELEVATION (FT) = 11.50 V= WIND VELOCITY (MPH) = 146 I = IMPORTANCE FACTOR = 1.00 EXPOSURE CATEGORY C ROOF GEOMETRY : H (FT) = 3.00 L (FT) = 12.00 ROOF SLOPE (DG)= 14.03 • Kz= EXPOSURE COEFFICIENT = 0.85 Kd= WIND DIRECTIONALITY FACTOR = 0.85 •••• • • V = VELOCITY PRESSURE = 0.00256 x Kz x Kd x V2 x I = 39.43 PSF • • • • • • • • • •• • • • • • • • • APPLY REDUCTION PER ROOF SLOPE LESS THAN 10 GR NO • • • • • PERCENT OF REDUCTION = 0 CPI COEFFICIENTS = + / - 0.18 a = ZONE 5 EXTENSION (FT) = 3.00 SMALLER BETWEEN : BUT NOT LESS THAN : • a =0.10 B= 2.55 AND a =0.4 H= 4.60 = 2.55 4% OF B= 1.02 OR 3.00 • • • • • • • • • ▪ • • • • •••• •• •• ••..•• • • • • •• • •• • • • • • • • . • • • • • • • • • • • • • •• • • • • • • • • GISELA REY, P.E. 14921 SW 30th TER Miami, Florida 33185 Phone: 305 229 -8374 Fax 305 226 -6904 By GR Date 2/1/11 Sheet 2 • Of 4 Project: ANGELICA MONTERO RESIDENCE WIND LOAD SUMMARY MARK WIDTH HEIGHT EFFECT WIND AREA ZONE 4 ZONE 6 ZONE 4 ZONE 5 GCP GCP GCP GCP WL WL WL WL POSITIVE NEGATIVE POSITIVE NEGATIVE POSITIVE NEGATIVE POSITIVE NEGATIVE IN IN SF PSF PSF PSF PSF HR -53 1/8" X 50 5 /8 "(A,B,D) HR -74" X 50 5/8" ( C) HR -37" X 38 3/8" (E) FD-60" X 80" (101) SH -19 1/8" X 38 3/8" (F) HR -37" X 50 5/8" (G,I) CAS -37" X 50 5/8" (H) 26.50 50.63 9.32 1.00 -1.10 1.00 -1.40 46.52 -50.47 46.52 -62.29 37.00 50.63 13.01 0.99 -1.09 0.99 -1.38 46.03 -49.97 46.03 -61.31 18.50 38.38 4.93 1.00 -1.10 1.00 -1.40 46.52 -50.47 46.52 -62.29 30.00 80.00 16.67 0.98 -1.08 0.98 -1.35 45.54 -49.48 45.54 -60.32 19.13 19.19 2.55 1.00 -1.10 1.00 -1.40 46.52 -50.47 46.52 -62.29 18.50 50.63 6.50 1.00 -1.10 1.00 -1.40 46.52 -50.47 46.52 -62.29 37.00 50.63 13.01 0.99 -1.09 0.99 -1.38 46.03 -49.97 46.03 -61.31 • •• ••• • • • • • •• • • • • • • • •• ••• •• • • • •• ••• ••• ••• • • • • • • • • • • N `41 • • • • • • • • .. •• •. •. . • • • ••• ••• • ••• • • • • • • • .•. • • • • • • • • • •.• • • • • • • • • • • • • •• • • • •• •• • • ••• • • II • • GISELA REY, P.E. 14921 SW 30th TER Miami, Florida 33185 Phone: 305 229 -8374 Fax 305 226 -6904 By GR Date 2/1/11 Sheet 2 Of 4 Project: ANGELICA MONTERO RESIDENCE PRODUCT APPROVAL REVIEW MARK OPENING LOCATION SIZE NOA NUMBER NOA DESIGN PRESSURE RATING OPENING REQ'D PRESSURE RATING EGRESS REQUIREMENT SHUTTER REQUIREMENT WIDTH HEIGHT POSITIVE NEGATIVE POSITIVE NEGATIVE IN IN _ PSF PSF PSF PSF YES NO YES NO A BEDROOM #1 53.13 50.63 08- 0107.08 53.33 -88.40 46.52 -50.47 x x B LIVING ROOM 53.13 50.63 08- 0107.08 53.33 -88.40 46.52 -50.47 x x C FAMILY ROOM 74.00 50.63 08- 0107.08 53.33 -67.30 46.03 -49.97 x x D FAMILY ROOM 53 13 50.63 08- 0107.08 53.33 -88.40 46.52 -50.47 x x E FAMILY ROOM 37.00 38.38 08 -0107.08 53.33 - 120.00 46.52 -50.47 x x 101 DINING ROOM 60.00 80.00 08- 0417.05 70.00 -70.00 45.04 -48.99 x x F BATH 19.13 38.38 08- 0219.03 80.00 -90.00 46.52 -50.47 x x G BEDROOM #2 37.00 50.63 08- 0107.08 53.33 - 104.70 46.52 -50.47 x x H BEROOMD #2 37.00 50.63 08- 0604.01 75.00 -80.00 46.03 -49.97 x x I BEDROOM #1 37.00 50.63 08- 0107.08 53.33 - 104.70 46.52 -50.47 x x .. ... • • • • • .. • • • • • • • .. 0.. 00 • • • 00 000 000 4100 • • • • • • • • • • .. .. .. • • • • • • • 00. 00. • ... • • • • 0 41 0 • • • • • • • • • • • • • 000 • • • • • • • • • • • • • • 00 00 • • • 00 00 000 • • • 000 • • • �5 •. ••• • • • • • • • • • • • •• •. • FLOoR PLA1.1 ••. •••• •••• • • • . • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •• ••• ••• • • • • • • • •••• ••• • ••• • • • • •.• • • • • • • • • • • • • • • • • • • 0 • • ••• • • • • • • • • • . • • • • • • • • • • • • • • •••••• • • •••• ••. • • • • ••• • • • UM.: AMGLJCA Q0KIT o 4PD E : t338 NW MtZmt FL. 33[EO • BUILDING CODE COMPLIANCE OFFICE (BCCO) PRODUCT CONTROL DIVISION NOTICE OF ACCEPTANCE (NOA) Sunshine Windows Manufacturing, Inc. 1745 West 33rd Place Hialeah, FL 33012 SCOPE: MIAMI -DADE COUNTY, FLORIDA METRO -DADE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 MIAMI, FLORIDA 33130 -1563 (305) 375 -2901 FAX (305) 372 -6339 www.maimidade.gov /buildinecode This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by Miami -Dade County Product Control Division and accepted by the Board of Rules and Appeals (BORA) to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration -date stated below. The Miami -Dade County Product Control Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right to revoke this acceptance,Jf it is _determined b-y Miami -Dade Cnnnty Aroduct_Controf Division that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION: Series 2000 Aluminum Single Hung Window — L.M.I. APPROVAL DOCUMENT: Drawing No. SH08 -01, titled "Series 2000 Aluminum Single Hung Impact Resistant Window", sheets 1 through 6 of 6, dated 01/25/08, prepared by manufacturer, signed and sealed by Francisco Hernandez, P.E., bearing the Miami -Dade County Product. Control Approval stamp with the Notice of Acceptance number and approval date by the Miami -Dade County Product Control Division. MISSILE IMPACT RATING: Large and Small Missile Impact Resistant • • •••• LABELING: Each unit shall bear a permanent label with the manufacturer's name orlego,•city, slete n 1 following statement: "Miami -Dade County Product Control Approved ", unless otherMs% i1'c ted her iI'l. " RENEWAL of this NOA shall be considered after a renewal application has been fileel l there hgs been no change in the applicable building code negatively affecting the performance of thin' }ptaddct. '..'.: TERMINATION of this NOA will occur after the expiration date or if there has beeRt'$ fe sion clripAppge in the materials, use, and/or manufacture of the product or process. Misuse of this NUA aran endoIsement of any product, for sales, advertising or any other purposes shall automatically terminate.fhisMI)A. Failure to • • • • . • • • • • .. comply with any section of this NOA shall be cause for termination and removal of NOA. • • ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, klatda, and followed • by the expiration date may be displayed in advertising literature. If any ortion of the NOA is dis a �eJ then Y P Y g YP PAY it shall be done in its entirety. INSPECTION: A copy of this entire NGA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA consists of this page 1 and evidence pages E-1 and E -2, as well as approval document nientioned above. The submitted documentation was reviewed by Manuel Perez, P.E. NOA No. 08- 0219.03 Expiration Date: April 24, 2013 Approval Date: April 24, 2008 Page 1 • Sunshine Windows Manufacturing, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED A. DRAWINGS 1. Manufacturer's die drawings and sections. 2. Drawing No SH08 -01, Sheets 1 through 6 of 6, titled "Series 2000 Aluminum Single Hung Impact Resistant Window ", dated 01/25/08, prepared by manufacturer, signed and sealed by Francisco Hernandez, P.E. B. TESTS 1. Test report >>n: 1) Air Infiltration Test, per FBC, TAS 202 -94 2) Uniform Static Air Pressure Test, Loading per FBC TAS 202 -94 3) Water Resistance Test, per FBC, TAS 202 -94 4) Large Missile Impact Test per FBC, TAS 201 -94 5) Cyclic Wind Pressure Loading per FBC, TAS 203 -94 6) Forced Entry Test, per FBC 2411 3.2.1, TAS 202 -94 along with marked -up drawings and installation diagram of series 2000 aluminum single hung window, prepared by Fenestration Testing Laboratory, Inc., Test Report No. FTL -5253, dated 10/02/07, signed and sealed by Carlos S. Rionda, P.E. 2. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202 -94 2) Uniform Static Air Pressure Test, Loading per FBC TAS 202 -94 • 3) Water Resistance Test, per FBC, TAS 202 -94 4) Large Missile Impact Test per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading per FBC, TAS 203 -94 6) Forced Entry Test, per FBC 2411 3.2.1, TAS 202 -94 along with marked -up drawings and installation diagram of series 2000 aluminize single hung window, prepared by Fenestration Testing Laboratory, Inc TestRvport No. FTL -5252, dated 08/17/07, signed and sealed by Carlos S. Ri'tfnd4 P.E.. • • • •• •• • •• C. CALCULATIONS • • 1. Anchor verification calculations and structural analysis, complyi epwith FBC:20Gli, • prepared by manufacturer, dated 12/22/07, signed and sealed by Primetsco HH ndez, • • P.E. • • • • • • Complies with ASTM E1300 -02 • • • • • • •. • D. QUALITY ASSURANCE • • . • • • • • • 1. Miami Dade Building Code Compliance Office (BCCO). E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 05- 1208.02 issued to E.I. DuPont DeNemours & Co., Inc. for their "DuPont Butacite PVB Interlayer" dated 01705/06, expiring on 12/11/10. • E -1 Manuel Pere Product Control Ex NOA No. 08-02 '.03 Expiration Date: April 24, 2013 Approval Date: April 24, 2008 • • • • Sunshine Windows Manufacturing, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED F. STATEMENTS 1. Statement letter of conformance, dated February 6, 2008, signed and sealed by Francisco Hernandez, P.E. 2. Statement letter of no financial interest, dated February 6, 2008, signed and sealed by Francisco Hernandez, P.E. 3. Laboratory compliance letter for Test Report No. FTL -5252 issued by Fenestration Testing Laboratory, Inc., dated 08/28/07, signed and sealed by Carlos S. Rionda, P.E. 4. Laboratory compliance letter for Test Report No. FTL -5253 issued by Fenestration Testing Laboratory, Inc., dated 10/10/07, signed and sealed by Carlos S. Rionda, P.E. G. OTHER 1. None. E -2 • • • • ...• • • • .. • • • . • • .... • • • • •••• • • • • • .. .... ▪ • .... • • • . .... • • .. • • • • • .. .. • • • • • • Manuel erez, Product Control Exa NOA No. 08 -0219. i 3 Expiration Date: April 24, 2013 Approval Date: April 24, 2008 • • • • • WINDOW HEIGHT HEAD ANCHORS SEE CHART 4" 10 "MAX. Al. •A2; I ;A3; 1 i FALSE MUNTINS (SURFACE APPLIED) MAY BE USED TIPICAL ELEVATION 1 OVER 1 GENERAL NOTES: 1.- FOR NUMBER OF ANCHORS FOR EACH UNIT SIZE REFER TO DESIGN PRESSURE CHART. 2.- REFERENCES: TEST REPORTS FTL -5252 AND FTL -5253. 3.- THIS PRODUCT MEETS THE REQUIREMENTS OF THE 2004 FLORIDA BUILDING CODE. 4.- FASTENERS MUST BE MADE OF STAINLESS STEEL OR HAVE ADEQUATE PROTECTION AGAINST CORROSION AS PER DIN 50018. ALUMINUM CONTACTING METALS SHALL BE PROPERLY PROTECTED. MIAMI- DADE IMPACT RESISTANT SHUTTERS ARE NOT REQUIRED DESIGN PRESSURE CHART - PSF SERIES -2000 ALUMINUM SINGLE HUNG IMPACT RESISTANT WINDOW WINDOW DIMENSION ANCHOR SCHEDULE DISIGN PRESSURE -PSF WIDTH HEIGHT PER sz PER JAMB EXT. INT. 19 1/8" 3 3 90.0 90.0 26 1/2" 26 " 3 90.0 90.0 37" 4 90.0 90.0 53 1/8" 6 - 75.0 75.0 19 1 8 ") - 3 /8 "l- - - 4 -,y '- - 90.0 90.0 26 1/2 "._- �.38 90,0 90.0 37" 4 90.0 90.0 53 1/8" 6 75.0 75.0 19 1/8" 50 5/8 " 3 6 90.0 90.0 26 1/2" 3 90.0 90.0 37" 4 90.0 90.0 53 1/8" 6 75.0 75.0 19 1/8" 63" 3 % 75.0 75.0 26 1/2" 3 75.0 75.0 37" 4 75.0 75.0 , 53 1/8" 6 75.0 75.0 19 1/8" 74 1/4" 3 8 75.0 75.0 26 1/2" 3 75.0 75.0 370 4 75.0 75.0 53 1/8" 6 75.0 75.0 IMPACT RESISTANT WINDOW Approved as coeiplying with the Florida ; _ , ag Date ... NO �lLeir Misted Dade Product C / )' Q --020b FRANCISCO HERNANDEZ FLORIDA PE # 51393 ................ ............... Sunshine Windows Manufacturing, Inc. 1745 W. 33rd Place Hialeah. Florida 33012 Ph: (305)364 -9952 Fax:(305)828 -5118 SERIES 2000 ALUMINUM Drawn 6v: RF Dote: 04-02-08 Scale: 1/2"=1* Redston: Revision: DRAWING NO. SHOE --01 SHEET 1 OF 6 DETAIL Al ATTACHMENT TO MASONRY GLAZING DETAIL TYPICAL ANCHORS 1/4" TAPCONS 1 1/4" MIN. EMBEDMENT INTO MASONRY THROUGH 1" BY W000 BUCK (FOR MAX. ANCHOR SPACING AND NUMBER OF ANCHORS REFER TO SHEET 1 OF 6) 1YPICAL ANCHORS TYPICAL ANCHORS 1/4" SMS 1 1/2" MIN. PENETRATION INTO W000. (FOR MAX. ANCHOR SPACING AND NUMBER OF ANCHORS REFER TO SHEET 1 OF 6) DETAIL A2 ATTACHMENT TO WOOD 1/4" SMS THROUGH METAL. (FOR MAX. ANCHOR SPACING AND NUMBER OF ANCHORS REFER TO SHEET 1 OF 6) DETAIL A3 ATTACHMENT TO METAL STRUCTURE DETAIL (STEEL. OR ALUMINUM 1/8" MIN. THICKNESS) TYPICAL HEAD SECTIONS IMPACT RESISTANT WINDOW Appraved as d1a!sp731b g whit Ste Florida Date ! '.. X NOAR A7+yli=M. Ptudast _ 02 -08 FRANCISCO HERNANDEZ FLORIDA PE # 51393 li iili M"'i I' Sunshine Windows Manufacturing, Inc. 1748 W. 33rd Place Hialeah, Florida 33012 Ph: (305)384 -9952 Fax:(305)828 -5118 SERIES 2000 ALUMINUM Drown Bv: RF Date: 04-02-08 Scale: 1 /2'al' Revision: Revision: DRAWING NO. SH08 --04 SHEET 2 OF 6 • o 4 • 4 4 • 4 • 4, • •4, 2 1/2" MIN. 2 1/2" MIN. 'TYPICAL ANCHORS 1/4" TAPCONS 1 1/4* MIN. EMBEDMENT INTO MASONRY (FOR MAX. ANCHOR SPACING AND NUMBER OF ANCHORS REFER TO SHEET 1 OF 8) DETAIL Cl ATTACHMENT TO PRE-CAST SILL 2" BY WOOD BUCK TYPICAL ANCHORS 1/4* SMS 1 1/2" MIN. PENETRATION INTO WOOD. (FOR MAX. ANCHOR SPACING AND NUMBER OF ANCHORS REFER TO SHEET 1 OF 6) DETAIL C3 ATTACHMENT TO WOOD g 2 \N 3/4" MAX. NON- SHRINK GROUT OR 1" BY W000 BUCK • 2 1/2" MIN. r 2 1/2" MIN. TYPICAL ANCHORS 1/4* TAPCONS 1 1/4" MIN. EMBEDMENT INTO MASONRY THROUGH 1" BY WOOD BUCK OR NON SHRINK NON METALLIC GROUT (FOR MAX. ANCHOR SPACING AND NUMBER OF ANCHORS REFER TO SHEET 1 OF 6) DETAIL C2 ATTACHMENT TO MASONRY TYPICAL ANCHORS 1/4" SMS THROUGH METAL. (FOR MAX. ANCHOR SPACING AND NUMBER OF ANCHORS REFER TO SHEET 1 OF 6) DETAIL C4 ATTACHMENT TO METAL STRUCTURE (STEEL OR ALUMINUM 1/8" MIN. THICKNESS) TYPICAL SILL SECTIONS IMPACT RESISTANT WINDOW APPrnvaai 9r •omplyiag with t$ Florida +.skiing ''e s Dote 1�� M1amiI iKhPrix1 4 0 • 4-02_08 FRANCISCO HERNANDEZ FLORIDA PE # 51393 Sunshine Windows Manufacturing, Inc. 1745 W. 33rd Piece Hialeeh. Reddo 33012 Ph: (305)364 -9952 Fox:(305)828 -5118 Drown RF Dote: 04 -02 -08 Scale: 1/2"=1' Revision: Revision: DRAWING NO. SH08 --05 SHEET 30F6 • 1/4" MAX. SHIM SPACE TYPICAL ANCHORS TYPICAL ANCHORS 1/4° SMS 1 1/2° MIN. PENETRATION INTO WOOD. (FOR MAX. ANCHOR SPACING AND NUMBER OF ANCHORS REFER TO SHEET 1 OF 6) DETAIL D2 ATTACHMENT TO WOOD 1/4° TAPCONS 1 1/4" MIN. EMBEDMENT INTO MASONRY THROUGH 1° BY WOOD BUCK (FOR MAX. ANCHOR SPACING AND NUMBER OF ANCHORS REFER TO SHEET 1 OF 6) DETAIL Dl ATTACHMENT TO MASONRY TYPICAL ANCHORS —1/4" SMS THROUGH METAL (FOR MAX. ANCHOR SPACING AND NUMBER OF ANCHORS REFER TO SHEET 1 OF 6) DETAIL VALIDS FOR JAMBS, HEAD AND SILL MIAMI —DADE COUNTY APROVED ULLION ATTACHMENT TO MULLION DETAIL TYPICAL JAMB SECTIONS IMPACT RESISTANT WINDOW 1/4" MAX. SHIM SPACE TYPICAL ANCHORS 1/4° SMS THROUGH METAL. (FOR MAX. ANCHOR SPACING AND NUMBER OF ANCHORS REFER TO SHEET 1 OF 6) DETAIL D3 ATTACHMENT TO METAL STRUCTURE (STEEL OR ALUMINUM 1/8" MIN. THICKNESS) Approead En emptying wtA the FEardztu Id&ng Date eig° i NO 01.;fl'I ✓LXIx [Miami r- : ; hugest BY 4_ of_ Of FRANCISCO HERNANDEZ FLORIDA PE # 51393 Sunshine Windows Manufacturing, Inc. 1745 W. 33rd Place Hialeah, Florida 33012 Ph: (305)384 -9952 Fax:(305)828 -5116 Drown Bv: RF Sc 04 1'>3 Scale: Revision: Revision: DRAWING N0. SH08 --06 SHEET 40F6 (SEE DETAILS C1, C2, C3 AND C4 ON SHEET 3 OF 6) VERTICAL SECTION 8 115 ;10? (16; WINDOW WIDTH (SEE DETAILS 01, D2 AND D3 ON SHEET 4 OF 6) HORIZONTAL SECTION VERTICAL SECTION WITH TOP LOCK IMPACT RESISTANT WINDOW Approved as complying with the Flan.:. Date ,C I�. NO �„ OLOBriLiiitlrix / 4_o2_oe, FRANCISCO HERNANDEZ FLORIDA PE # 51393 Sunshine Windows Manufacturing, Inc. 1745 W. 33rd Place Hialeah, Florida 33012 Ph: (305)384 -9952 Fax:(305)828 -5118 Drown gy RF Dote: 04 -02 -08 Scale: 1/2•=1' Revision: Revision: DRAWING NO. SHO8 -02 SHED- 5 OF 6 On' I---- 1.312 2.062 ----1 0.050 --1-- - 0.812 H F- 0.304 0 57 0 0.395 444 I MATERIAL 0.812 h 2.125 1.760 1_ FRAME HEAD 1.250 It_ I SW52101 1 FRAME SILL 8063 -T5 GLAZING BEAT SWW -101 6063 -T6 MEETING RAIL SW -015 6063 -T5 -,' , FRAME HEAD SW -014 6063 -T5 FRAME JAMB --, 0 937 I-- 4 1--- 1.625 ---1 ,._ 2.127 ' 0.062 2.314 5 2.000 1 0.050 1.875 SASH SW 6063 � 0.050 SASH BOTTOM RAIL 6063 -T5 7 SW8202B 2 SASH CAM NYLON 8 0.812 1-- TOP RAIL -017 -75 0.68 -1.._.I--- 2.078 ----I FRAME SILL SW -52101 6063 -15 2.375 - ---- - FRAME JAMB SW -011 6063 -75 I--- 1.890 ----I ---I-- 0.1870 -1 h 2.750 10 SW8202A 4 /VENT 0 0.062 j--- RAIL I- 0.592 1.0100 L --I 0.810 SASH SW 6063 0.050 LATCH BOTTOM RAIL 0.7119 1•.�, 1324 1-- SIDE RAIL -012 T5 . ,1, SASH BOTTON RAIL PLASTIC KOCETAL K300 SW -43353 *-I 1.000 SASH BOTTOM SW -43355 6063 -T5 MATERIAL LIST ITEM # PART # REQD. DESCRIPTION MATERIAL 1 SW -014 1 FRAME HEAD 6063-T5 2 SW52101 1 FRAME SILL 8063 -T5 3 SW -011 2 FRAME JAMB 6063 -T5 4 SW40111 1 MEETING RAIL 6063 -T5 5 SW -017 1 SASH TOP RAIL 6063 -T5 6 SW43355 1 SASH BOTTOM RAIL 6063 -T5 7 SW8202B 2 SASH CAM NYLON 8 SW -012 2 SASH SIDE RAIL 6063 -T5 9 SW -AS AS REQ ASSEMBLY SCREWS # 8X1" PH PHIWP CRS 10 SW8202A 4 /VENT FACE GUIDES NYLON 11 SW43353 2/VENT LATCH BOTTOM RAIL PLASTIC 12 SW1820 AS RQD SEAL PILE FELT 13 SW3257 AS RQD WEATHER STRIP BULB VINYL 14 - AS RQD SIUCONE DC- 899/GE -1200 15 SWW1O1 AS ROD GLAZING BEAD 6063 -T6 16 SW540 2 SPIRAL BALANCE ALUMINUM 17 SW -667 2/VENT LATCH ZINC 18 SW3082 AS RQD WEATHER STRIP BULB VINYL IMPACT RESISTANT WINDOW FRANCISCO HERNANDEZ FLORIDA PE # 51393 Sunshine Windows Manufacturing, Inc. 1746 W. 33rd Place Hialeah, Flortdo 33012 Ph: (305)384 -9952 Fc:c(305)828 -5118 F ij Drown Or RF Date: 04 -02 -08 Scole: 1/2 " =1' Revision: Revision: DRAWING NO. SHOE —O3 SHEET 6 OF 6 { 0 BUILDING CODE COMPLIANCE OFFICE (BCCO) PRODUCT CONTROL DIVISION NOTICE OF ACCEPTANCE (NOA) Florida Window Systems, Corp. 7191 NW 77 Terr. Medley, FL 33166 SCOPE: MIAMI -DADE COUNTY, FLORIDA METRO -DADE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 MIAMI, FLORIDA 33130 -1563 (305) 375 -2901 FAX (305) 372 -6339 www.maimidade.aov/buildinacode This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by Miami -Dade County Product Control Division and accepted by the Board of Rules and Appeals (BORA) to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Division that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION: Outswing Aluminum Casement Window — L.M.L APPROVAL DOCUMENT: Drawing No. W03 -36, titled "Alum. Outswing Casement Window (L.M.I.)", sheets 1 through 6 of 6, dated 05/28/03 with revision B 06/20/07, prepared by Al- Farooq, Corporation, signed and sealed by Humayoun Farooq, P.E., bearing the Miami -Dade County Product Control Revision stamp with the Notice of Acceptance number and expiration date by the Miami -Dade County Product Control Division. MISSILE IMPACT RATING: Large and Small Missile Impact Resistant LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement' "Miami -Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises and renews NOA # 03- 0612.04 and consists of this page 1 and evidence pages E -1 and E -2, as well as approval document mentioned above. The submitted documentation was reviewed by Manuel Perez, P.E. NOA No. 08- 0604.01 Expiration Date: September 18, 2013 Approval Date: October 02, 2008 Page 1 r Florida Window Systems, Corp. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED A. DRAWINGS 1. Manufacturer's die drawings and sections. 2. Drawing No W03 -36, Sheets 1 through 6 of 6, titled "Alum. Outswing Casement Window (L.M.I.) ", dated 05/28/03 with revision B dated 06/20/07, prepared by Al- Farooq Corporation, signed and sealed by Humayoun Farooq, P.E. B. TESTS 1. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202 -94 2) Uniform Static Air Pressure Test, Loading per FBC, TAS 202 -94 3) Water Resistance Test, per FBC, TAS 202 -94 along with marked -up drawings and installation diagram of an aluminum casement window, prepared by Hurricane Engineering & Testing, Inc. Test Report No. HETI -03 -1312 dated 4/17/03, signed and sealed by Rafael Droz, P.E. (Submitted under previous NOA #03- 0612.04) 2. Test reports on: 1) Large Missile Impact Test per FBC, TAS 201 -94 2) Cyclic Wind Pressure Loading per FBC, TAS 203 -94 along with marked -up drawings and installation diagram of an aluminum casement vinyl window, prepared by Hurricane Engineering & Testing, Inc. Test Report No. HETI -02 -1752 dated 12/3/02, signed and sealed by Rafael Droz, P.E. (Submitted under previous NOA #03- 0612.04) 3. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202 -94 2) Uniform Static Air Pressure Test, Loading per FBC, TAS 202 -94 3) Water Resistance Test, per FBC, TAS 202 -94 along with marked -up drawings and installation diagram of an aluminum casement vinyl window, prepared by Hurricane Engineering & Testing, Inc. Test Report No. HETI -02 -1230 dated 6 /23/02, signed and sealed by Rafael Droz, P.E. (Submitted under previous NOA #03- 0612.04) 4. Test reports on:1) Large Missile Impact Test per FBC, TAS 201 -94 2) Cyclic Wind Pressure Loading per FBC, TAS 203 -94 along with marked -up drawings and installation diagram of an aluminum casement vinyl window, prepared by Hurricane Engineering & Testing, Inc. Test Report No. HETI -02 -1751 dated 12 /3/02, signed and sealed by Rafael Droz, P.E. (Submitted under previous NOA #03- 0612.04) 5. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202 -94 2) Uniform Static Air Pressure Test, Loading per FBC, TAS 202 -94 3) Water Resistance Test, per FBC, TAS 202 -94 along with marked -up drawings and installation diagram of an aluminum casement vinyl window, prepared by Hurricane Engineering & Testing, Inc. Test Report No. HETI -02 -1235 dated 7/3/02, signed and sealed b Rafael Droz, P.E. (Submitted under previous NOA #03- 0612.04) E -1 Manuel P P.E. Product Control . - miner NOA No. 08- 0604.01 Expiration Date: September 18, 2013 Approval Date: October 02, 2008 • • Florida Window Systems, Corp. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED C. CALCULATIONS 1. Anchor verification calculations and structural analysis, complying with FBC -2004, prepared by Al- Farooq Corporation, dated 6/18/07, signed and sealed by Humayoun Farooq, P.E. Complies with ASTM E1300 -02 D. QUALITY ASSURANCE 1. Miami Dade Building Code Compliance Office (BCCO). E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 03- 0916.02 issued to Nebula Glass International, Inc. for their "Glasslam Safety- Plus - Laminated Glass" dated 10/23/03, expiring on 09/09/08. 2. Notice of Acceptance No. 06- 0216.06 issued to Solutia Inc. for their "Saflex IIIG Clear or colored interlayer" dated May 04, 2006, expiring on May 21, 2011. F. STATEMENTS 1. Statement letter of conformance, dated June 18, 2007, signed and sealed by Humayoun Farooq, P.E. 2. Statement letter of no financial interest, dated June 18, 2007, signed and sealed by Humayoun Farooq, P.E. G. OTHER 1. Notice of Acceptance No. 03- 0612.04, issued to Florida Window Systems for their Aluminum Casement Window, approved on 09/18/03 and expiring on 09/18/08. E -2 Manu PerezAd; Product Control Exa Iffrrr NOA No. 08 -0604.01 Expiration Date: September 18, 2013 Approval Date: October 02, 2008 13 1/2" MAX. HEAD /SILL SIUCONE DOW CORNING 995 GE 4000 5" MAX. HEAD /SILL CORNERS 'r -i ice- 30 15/16" D.L. OPG. 35 7/8° 1/8° ANN. GLASS 060" INTERLAYER GLASSLAM SAFETY -PLUS f.010" PET FILM .060" INTERLAYER GLASSLAM SAFETY -PLUS 1/8° ANN. GLASS VENT WIDTH 37" WINDOW WIDTH SINGLE VENT WDW, z m (n 1! SIUCONE DOW CORNING 995 GE 4000 [7732 GLASS TYPE 'Al' 1 ANCHOR REQD. AT EACH SIDE OF IMPOST SURFACE APPUED FALSE MUNTINS OPTIONAL 13 1/2° MAX. HEAD /SILL WINDOW HEIGH 5° MAX. HEAD /SILL CORNERS N rel 30 15/16" D.L. OPG. 35 7/8° VENT WIDTH 30 15/16° O.L. OPG. 35 7/8° SIUCONE TREMCO TREMGLAZE S -500 1/8" ANN. GLASS .090" INTERLAYER SAFLEX /KEEPSAFE MAXIMUM 1/8° ANN. GLASS SIUCONE TREMCO TREMGLAZE S -500 z GLASS TYPE 'A2' GLAZING OPTIONS 74" WINDOW WIDTH DUAL VENT wow, VENT WIDTH SIUCONE DOW CORNING 995 GE 4000 1/8° HEAT STREN'D. GLASS .060" INTERLAYER GLASSLAM SAFETY -PLUS .010° PET FILM 060° INTERLAYER GLASSLAM SAFETY -PLUS 1/8° HEAT STREN'D. GLASS SIUCONE DOW CORNING 995 GE 4000 GLASS TYPE 'B1' g THESE WINDOWS ARE RATED FOR LARGE MISSILE IMPACT. SHUTTERS ARE NOT REQUIRED. ALUMINUM OUTSWING CASEMENT WINDOW DESIGN LOAD RATINGS FOR THESE WINDOWS TO BE AS PER CHARTS SHOWN ON SHEET 2. APPROVAL APPUES TO SINGLE VENT OR DUAL VENT WINDOWS WITH X AND XX CONFIGURATIONS. ALSO COMBINATIONS OF CASMT /CASMT OR CASMT WITH OTHER WINDOW TYPES IN MODULES OF TWO OR MORE WINDOWS USING MIAMI -DADE COUNTY APPROVED MULLIONS IN BETWEEN. LOWER DESIGN PRESSURE FROM WINDOWS OR MULLION APPROVAL WILL APPLY TO ENTIRE SYSTEM. THIS PRODUCT HAS BEEN DESIGNED AND TESTED TO COMPLY WITH THE REQUIREMENTS OF THE FLORIDA BUILDING CODE 2004 EDITION INCLUDING HIGH VELOCITY HURRICANE ZONE (HVHZ). WOOD BUCKS BY OTHERS, MUST BE ANCHORED PROPERLY TO TRANSFER LOADS TO THE STRUCTURE. ANCHORS SHALL BE AS LISTED, SPACED AS SHOWN ON DETAILS, ANCHORS EMBEDMENT TO BASE MATERIAL SHALL BE BEYOND WALL DRESSING OR STUCCO. ANCHORING OR LOADING CONDITIONS NOT SHOWN IN THESE DETAILS ARE NOT PART OF THIS APPROVAL. A LOAD DURATION INCREASE IN ALLOWABLE STRESS IS USED IN DESIGN OF ANCHORS INTO WOOD ONLY. MATERIALS INCLUDING BUT NOT LIMITED TO STEEL/METAL SCREWS, THAT COME INTO CONTACT WITH OTHER DISSIMILAR MATERIALS SHALL MEET THE REQUIREMENTS OF 2004 FLORIDA BLDG. CODE SECTION 2003.8.4. Engr. DR. HUMAYOUN FAROOQ STRUCTURES nA. PE if 16557 C.A.N..535 PRODUCT USED is eareplyhtswitheerkStlif Belding Cede Acceptslee No s Bate tip V 3' 0 0 IJ W NW 0 2 g W 3g Q CO o CO zr7 N z O Z; °' EL A1 FAX (305) 805 -9424 co in 0 � . 5 c O a a0i 5 z 5 2 a % T .0 0 0 0 0 O c m • drawing no. W03 -36 sheet 1 of 6 �1-I 11 / I / i // U pp — O \M \ 11 II u l \ \I - I I \ — - II \ \ ,,I,f / II / I / - -- -I V - -- D.L OPG. - / / \ \ \ _ / ,/ N 1 \\ II \ 1 /M / H 1I 5° MAX. HEAD /SILL CORNERS N rel 30 15/16" D.L. OPG. 35 7/8° VENT WIDTH 30 15/16° O.L. OPG. 35 7/8° SIUCONE TREMCO TREMGLAZE S -500 1/8" ANN. GLASS .090" INTERLAYER SAFLEX /KEEPSAFE MAXIMUM 1/8° ANN. GLASS SIUCONE TREMCO TREMGLAZE S -500 z GLASS TYPE 'A2' GLAZING OPTIONS 74" WINDOW WIDTH DUAL VENT wow, VENT WIDTH SIUCONE DOW CORNING 995 GE 4000 1/8° HEAT STREN'D. GLASS .060" INTERLAYER GLASSLAM SAFETY -PLUS .010° PET FILM 060° INTERLAYER GLASSLAM SAFETY -PLUS 1/8° HEAT STREN'D. GLASS SIUCONE DOW CORNING 995 GE 4000 GLASS TYPE 'B1' g THESE WINDOWS ARE RATED FOR LARGE MISSILE IMPACT. SHUTTERS ARE NOT REQUIRED. ALUMINUM OUTSWING CASEMENT WINDOW DESIGN LOAD RATINGS FOR THESE WINDOWS TO BE AS PER CHARTS SHOWN ON SHEET 2. APPROVAL APPUES TO SINGLE VENT OR DUAL VENT WINDOWS WITH X AND XX CONFIGURATIONS. ALSO COMBINATIONS OF CASMT /CASMT OR CASMT WITH OTHER WINDOW TYPES IN MODULES OF TWO OR MORE WINDOWS USING MIAMI -DADE COUNTY APPROVED MULLIONS IN BETWEEN. LOWER DESIGN PRESSURE FROM WINDOWS OR MULLION APPROVAL WILL APPLY TO ENTIRE SYSTEM. THIS PRODUCT HAS BEEN DESIGNED AND TESTED TO COMPLY WITH THE REQUIREMENTS OF THE FLORIDA BUILDING CODE 2004 EDITION INCLUDING HIGH VELOCITY HURRICANE ZONE (HVHZ). WOOD BUCKS BY OTHERS, MUST BE ANCHORED PROPERLY TO TRANSFER LOADS TO THE STRUCTURE. ANCHORS SHALL BE AS LISTED, SPACED AS SHOWN ON DETAILS, ANCHORS EMBEDMENT TO BASE MATERIAL SHALL BE BEYOND WALL DRESSING OR STUCCO. ANCHORING OR LOADING CONDITIONS NOT SHOWN IN THESE DETAILS ARE NOT PART OF THIS APPROVAL. A LOAD DURATION INCREASE IN ALLOWABLE STRESS IS USED IN DESIGN OF ANCHORS INTO WOOD ONLY. MATERIALS INCLUDING BUT NOT LIMITED TO STEEL/METAL SCREWS, THAT COME INTO CONTACT WITH OTHER DISSIMILAR MATERIALS SHALL MEET THE REQUIREMENTS OF 2004 FLORIDA BLDG. CODE SECTION 2003.8.4. Engr. DR. HUMAYOUN FAROOQ STRUCTURES nA. PE if 16557 C.A.N..535 PRODUCT USED is eareplyhtswitheerkStlif Belding Cede Acceptslee No s Bate tip V 3' 0 0 IJ W NW 0 2 g W 3g Q CO o CO zr7 N z O Z; °' EL A1 FAX (305) 805 -9424 co in 0 � . 5 c O a a0i 5 z 5 2 a % T .0 0 0 0 0 O c m • drawing no. W03 -36 sheet 1 of 6 DESIGN LOAD CAPACITY - PSF FOR ( X ) SIZES WINDOW DIMS. GLASS TYPES 'AI' .& 'A2' GLASS TYPE 'B1' WIDTH HEIGHT EXT. ( +) 1NT. ( -) EXT. ( +) 1NT. ( -) 19 -1/8" 26 -1/2" 37• 26' (3) 55.0 55.0 75.0 80.0 55.0 55.0 75.0 80.0 55.0 55.0 75.0 80.0 19 -1/8" 26 -1/2" 37" 38 -3/8" (4) 55.0 55.0 75.0 80.0 55.0 55.0 75.0 80.0 55.0 55.0 75.0 80.0 19 -1/8" 26-1/2" 37" 50 -5/8° (5) 55.0 55.0 75.0 80.0 55.0 55.0 75.0 80.0 55.0 55.0 75.0 80.0 19 -1/8' 26 -1/2° 37' 63" (5) 45.5 45.5 75.0 80.0 34.0 34.0 75.0 80.0 - - 75.0 80.0 19 -1/8' 26 -1/2° 74 -1/4° (6) 27.5 27.5 75.0 80.0 - - 66.8 66.8 18° 24" 30' 36" 24" (3) 55.0 55.0 75.0 80.0 55.0 55.0 75.0 80.0 55.0 55.0 75.0 80.0 55.0 55.0 75.0 80.0 18" 24" 30" 36" 36" (3) 55.0 55.0 75.0 80.0 55.0 55.0 75.0 80.0 55.0 55.0 75.0 80.0 55.0. 55.0 75.0 80.0 18" 24' 30" 36° 48" (4) 55.0 55.0 75.0 80.0 55.0 55.0 75.0 80.0 55.0 55.0 75.0 80.0 55.0 55.0 75.0 80.0 18° 24" 30" 36" 60" (5) 55.0 55.0 75.0 80.0 43.2 43.2 75.0 80.0 35.9 35.9 75.0 80.0 - - 75.0 80.0 18" 24" 30" 72" (6) 32.0 32.0 75.0 80.0 24.5 24.5 75.0 80.0 - - 66.0 66.0 () = NO. OF ANCHORS PER JAMB NOTE: GLASS CAPACITIES ON THIS SHEET ARE BASED ON ASTM E1300 -02 (3 SEC. GUSTS) AND FLORIDA BUILDING COMMISSION DECLARATORY STATEMENT DCA05- DEC- 219 DESIGN LOAD CAPACITY - PSF FOR ( XX ) SIZES WINDOW DIMS. UNREINFORCED CENTER POST REINFORCED CENTER POST GLASS TYPES 'Al' & 'A2' GLASS TYPE 'B I' GLASS TYPE 'B1' WIDTH HEIGHT EXT. ( +) 1NT. ( -) EXT. ( +) 1NT. ( -) Er. ( +) 1NT. ( -) 26 -1/2° 37' 53 -1/8" 74" 26" (3) 55.0 55.0 75.0 80.0 75.0 80.0 55.0 55.0 75.0 80.0 75.0 80.0 55.0 55.0 75.0 80.0 75.0 80.0 55.0 55.0 75.0 80.0 75.0 80.0 26 -1/2" 37° 53 -1/8° 74" 38-3/8" (4) 55.0 55.0 75.0 80.0 75.0 80.0 55.0 55.0 75.0 80.0 75.0 80.0 55.0 55.0 75.0 80.0 75.0 80.0 55.0 55.0 75.0 80.0 75.0 80.0 26 -1/2" 37" 53 -1/8° 74" 50 -5 /8" (5) 55.0 55.0 75.0 80.0 75.0 80.0 55.0 55.0 75.0 80.0 75.0 80.0 55.0 55.0 75.0 80.0 75.0 80.0 55.0 55.0 65.7 65.7 75.0 80.0 26 -1/2" 37' 53 -1/8" 74' 63" (5) 55.0 55.0 75.0 80.0 75.0 80.0 47.0 47.0 75.0 80.0 75.0 80.0 34.0 34.0 68.4 68.4 75.0 80.0 - - 52.8 52.8 75.0 80.0 26-1/2" 37" 53 -1/8" 74 -1/4° (6) 39.2 39.2 75.0 79.0 75.0 80.0 28.4 28.4 57.2 57.2 75.0 80.0 - - 40.9 40.9 66.7 66.7 24" 36° 48' 60" 72" 24" (3) 55.0 55.0 75.0 80.0 75.0 80.0 55.0 55.0 75.0 80.0 75.0 80.0 55.0 55.0 75.0 80.0 75.0 80.0 55.0 55.0 75.0 80.0 75.0 80.0 55.0 55.0 75.0 80.0 75.0 80.0 24" 36" 48" 60" 72" 36" (3) 55.0 55.0 75.0 80.0 75.0 80.0 55.0 55.0 75.0 80.0 75.0 80.0 55.0 55.0 75.0 80.0 75.0 80.0 55.0 55.0 75.0 80.0 75.0 80.0 55.0 55.0 75.0 80.0 75.0 80.0 24" 36" 48" 60" 72" 48" (4) 55.0 55.0 75.0 80.0 75.0 80.0 55.0 55.0 75.0 80.0 75.0 80.0 55.0 55.0 75.0 80.0 75.0 80.0 55.0 55.0 75.0 80.0 75.0 80.0 55.0 55.0 71.2 71.2 75.0 80.0 24" 36" 48' 60" 72" 6g ' () 55.0 55.0 75.0 80.0 75.0 80.0 55.0 55.0 75.0 80.0 75.0 80.0 43.2 43.2 75.0 80.0 75.0 80.0 35.9 35.9 68.4 68.4 75.0 80.0 - - 57.0 57.0 75.0 80.0 24" 36° 48' 60" 72" (6) 47.4 47.4 75.0 80.0 75.0 80.0 32.0 32.0 64.5 64.5 75.0 80.0 24.5 24.5 49.3 49.3 75.0 80.0 - - 40.5 40.5 66.0 66.0 () m NO. OF ANCHORS PER JAMB Engr. DR. HUMAYOUN FAROOQ STRUCTURES F1A PE # 16557 CAN. 3538 !"ROIDLJC ' REUSED ascm i,:, :,;,,; with IssZ Cade inV N® ^Fain Data J 0 w as Lt rgo- O O t 1- vo ( a0w' patio O o o-a rtg LL Wyk Z J co co .t a 0 N rn g O re c0 2 ;71 P94. o Q LL. ao 0z[j R 0 - '-J v 0 .0 C 0 0 0 0 a 0 drawing no. W03 -36 (sheet 2 of 6 TYPICAL ANCHORS SEE ELEV. FOR SPACING • 0 x z 8 z 1BY •WOOD BUCK 0 4 O w 11 Ij • x * N v. v. v • 2 N TYPICAL ANCHORS SEE ELEV. FOR SPACING TYPICAL ANCHORS SEE ELEV. FOR SPACING 7 N TYPICAL ANCHORS SEE ELEV. FOR SPACING MIAMI —DADE COUNTY APPROVED MUWON & MUWON ANCHORS SEE SEPARATE NOA TYPICAL ANCHORS _ SEE ELEV. FOR SPACING s 1 WOOD BUCKS AND METAL STRUCTURE NOT BY FLORIDA WDW. SYS. MUST SUSTAIN LOADS IMPOSED BY GLAZING SYSTEM AND TRANSFER THEM TO THE BUILDING STRUCTURE. TYPICAL ANCHORS: SEE ELEV. FOR SPACING 1/4" TAPCONS INTO 2BY WOOD BUCKS OR WOOD STRUCTURES 1-1/2" MIN. PENETRATION INTO WOOD THRU 1BY BUCKS INTO CONC. OR MASONRY 1-1/4" MIN. EMBED INTO CONC. OR MASONRY 3/16" TEKS OR SELF DRILLING SCREWS INTO METAL STRUCTURES STEEL : 12 GA. MIN. (Fy = 36 KSI MIN.) ALUMINUM : 1/8° THK. MIN. (6063 —T5 MIN.) (STEEL IN CONTACT WITH ALUMINUM TO BE PLATED OR PAINTED) 110 SMS OR SELF DRIWNG SCREW$ INTO DADE COUNTY APPROVED MUWONS (MIN. THK. = .090") (NO SHIM SPACE) TYPICAL EDGE DISTANCE INTO CONCRETE AND MASONRY = 1 -1 /4° MIN. INTO WOOD STRUCTURE = 3/4° MIN. INTO METAL STRUCTURE = 3/4° MIN. SEALANTS: ALL FRAME AND VENT CORNERS AND INSTALLATION SCREWS SEALED WITH CLEAR /ALUMINUM COLORED SEALANT. Engr. DR. HUMAYOUN UCTURES FAROOQ FLA. PE / 157 CAN. 353 d DUCT DEVISED e9 comp$i g with annul* Aomecmo Datee 1141.ac i'. t'rodnit !ir 1DIv,: ,m 0/ Z n 0 P 42 O gl u. O t a O 8 ZI p ttQa WNe t -V�cv< 4Ei 'P F to a 8 t ) 0 z w FAX (305) 805 -9424 c 0 n 0 v .o 4, 8 O 8 0 ,c drawing no. W03 -36 (sheet 3 of 6 3/16° MAX. SHIM TYPICAL ANCHORS SEE ELEV. FOR SPACING 1/2" X 5/8" X 2" LONG ALUM BARS. 2/ VENT AT 6° FROM TOP & BOTTOM FASTENED W/ (2) #8 X 1" FH SMS -v m 1/4° MAX. MIAMI —DADE COUNTY SHIM APPR,D MULLION SEE SEPARATE NOA 1BY 'WOOD BUCKS SCREEN OPT. 08 80,81=8 METAL STRUCTURE EXTERIOR D.L OPG. WINDOW WIDTH SINGLE VENT WINDOWS 1/2" X 5/8° X 2" LONG ALUM BARS. 2/ VENT AT 6' FROM TOP & BOTTOM FASTENED W/ (2) #8 X 1' FH SMS TYPICAL ANCHORS SEE ELEV. FOR SPACING STEEL REINFORCING SEE SHEET 2 FOR CAPACITIES (STEEL TO BE PAINTED WITH A HEAVY BODIED BITUMINOUS PAINT OR BE GALVANIZED) TYPICAL ANCHORS SEE ELEV. FOR SPACING WINDOW WIDTH WINDOW WIDTH 'TYPICAL ANCHORS SEE ELEV. FOR SPACING TYPICAL ANCHORS SEE ELEV. FOR SPACING DUAL VENT WINDOWS Engr. DR. HUMAYOUN FAROOQ STRUCTURES FLA PE # 16557 C.A.N. 3538 DUCT WitVifEil eifeWay tlil5.:anNaszc ea• R:. UN ate ?rack wAtt4 IL U z FFu as A Q 0 o 0g V ? ei h g aJO W tC W e yj O I UJ v 0 z z W La U C.7 0 COMP- ANL \W03 -36FWS t in c L. c 0 0. v 0 0 v 0 0 0 c m N 1 k Sa' J drawing no. W03 -36 sheet 4of 6 FRAME VENT 4.000 4.626 IMPOST .621 GLAZING BEAD .830 l [090 J 1.720 J REINFORCING CHANNEL 36 KSI STEEL ITEM PART iP QUANTITY DESCRIPTION MATERIAL. MANF. /SUPPLIER /REMARKS 1 FWS -009 4 FRAME 6063 —T6 — 2 FWS -011 4 VENT 6063 —T6 — 3 FWS -010 1 CENTER POST 6063 —T6 — 4 FWG -008 AS REQD. GLAZING BEAD 6063 —T5 — 5 — AS REQD. FRAME ASSEMBLY SCREWS ST. STEEL #10 X 3/4" PH SMS 6 — AS REQD. VENT ASSEMBLY SCREWS ST. STEEL #10 X 1 -1/2" PH SMS 7 E102 AS REQD. FRAME WEATHERSTRIPPING (.078 X .300) VINYL ULTRAFAB 8 E206 AS READ. VENT WEATHERSTRIPPING (.187 X .350) VINYL ULTRAFAB 9 34,12,00,100 2/ VENT 4 BAR HINGE, AT TOP AND BOTTOM STEEL TRUTH, ATTACHED W/ (6) /8 X 3/8' SS SMS 10 30066 2/ VENT LEVER TYPE FACE MOUNT LOCK STEEL TRUTH, AT 12' FROM TOP AND BOTTOM 11 21087 2/ VENT LOCK KEEPERS, AT FRAME JAMB FACING LOCK STEEL ATTACHED W/ (2) #10 X 3/8° S5 SMS 12 40066 1 ROTO OPERATOR STEEL TRUTH, ATTACHED W/ (4) #8 X 3/8" SS SMS 13 — — .057 THICK CORNER KEY ST. STEEL 1 -1/2" X 1 -1/2" X 1/2" 14 — 2/ LOCK LOCK INSTALLATION SCREWS — #12 X 1/2° PH SMS 15 — AS READ. CENTER POST REINFORCING STEEL — Engr. DR. HHUUMA E CTURES N FAR FLA. PE_1 _8557 CAN. 3538 PRODUCT REVISED as comply* with tax Floc Elt)Ia apt; Cali Amy-az= No Daia Op) z O h O IM � O 0.t CC 0 0 0 m O da O iimE • it u. IA - J0 Q 8 O FAX (305) 805 -9424 N c 0 Ol L c 0 a a0i m 0 .0 0 0 0 N 0 N O c CO 1 c drowing no. W03 -36 (sheet 5 of 6 ) • • • • IMPOST CORNER VENT CORNER FRAME CORNER ALL FRAME AND VENT CORNERS TO BE SEALED WITH WHITE /ALUM COLORED SEALANT. Engr. DR. HUMAYOUN FAROOQ STRUCTURES FLA. PE 16557 C.A.N. 3538 PRODUCE REVISED xararpty°. 273 wlar°a Itte tV T'ks keno R�t9 .ilwaLlin Data z H• w g 0 tz • t 4 v3 o'OWt) • c • W3a f/1 - J o c' • w�g 8 6 8 z w 0 �4 t x N VI 0 CO r+ 0 a 0 0 • m r—� fiu drawing no. W03 -36 (sheet 6 of 6 BUILDING CODE COMPLIANCE OFFICE (BCCO) PRODUCT CONTROL DIVISION NOTICE OF ACCEPTANCE (NOA Sunshine Windows Manufacturing, Inc. 1745 W. 33n1 Place Hialeah, FL 33012 SCOPE: MIAMI -DADE COUNTY, FLORIDA METRO -DADE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 MIAMI, FLORIDA 33130 -1563 (305) 375 -2901 FAX (305) 372 -6339 www.miamidade.eov/buiidinecode This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by Miami -Dade County Product Control Division and accepted by the Board of Rules and Appeals (BORA) to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Division that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION: Series 1650 Aluminum Horizontal Sliding Window — L.M.L APPROVAL DOCUMENT: Drawing No. HS08 -01, titled "Series 1650 Aluminum Horizontal Sliding Window (XO) Impact Resistant Glass ", sheets 1 through 7 of 7, dated 03/14/08, prepared by manufacturer, signed and sealed by Francisco Hernandez, P.E., bearing the Miami -Dade County Product Control Approval stamp with the Notice of Acceptance number and Approval date by the Miami -Dade County Product Control Division. MISSILE IMPACT RATING: Large and Small Missile Impact Resistant LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA consists of this page 1 and evidence pages E-1 and E -2, as well as approval document mentioned above. The submitted documentation was reviewed by Manuel Perez, P.E. NOA No. 08- 0107.08 Expiration Date: April 10, 2013 Approval Date: April 10, 2008 Page 1 • • • Sunshine Windows Manufacturing, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED A. DRAWINGS 1. Manufacturer's die drawings and sections. 2. Drawing No HS08 -01, titled "Series 1650 Aluminum Horizontal Sliding Window (XO) Impact Resistant Glass ", sheets 1 through 7 of 7, dated 03/14/08, prepared by manufacturer, signed and sealed by Francisco Hernandez, P.E. B. TESTS 1. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202 -94 2) Uniform Static Air Pressure Test, Loading per FBC TAS 202 -94 3) Water Resistance Test, per FBC, TAS 202 -94 4) Large Missile Impact Test per FBC, TAS 201 -94 5) Cyclic Wind Pressure Loading per FBC, TAS 203 -94 6) Forced Entry Test, per FBC 2411 3.2.1, TAS 202 -94 along with marked -up drawings and installation diagram of Aluminum Horizontal Sliding Window, prepared by Fenestration Testing Laboratory, Inc., Test Report No. FTL -5331, dated 09/18/07, signed and sealed by Carlos S. Rionda, P.E. 2. Test reports an: 1) Air Infiltration Test, per FBC, TAS 202 -94 2) Uniform Static Air Pressure Test, Loading per FBC TAS 202 -94 3) Water Resistance Test, per FBC, TAS 202 -94 4) Large Missile Impact Test per FBC, TAS 201 -94 5) Cyclic Wind Pressure Loading per FBC, TAS 203 -94 6) Forced Entry Test, per FBC 2411 3.2.1, TAS 202 -94 along with marked -up drawings and installation diagram of Aluminum Horizontal Sliding Window, prepared by Fenestration Testing Laboratory, Inc., Test Report No. FTL -5015, dated 07/27/07, signed and sealed by Carlos S. Rionda, P.E. C. CALCULATIONS 1. Anchor verification calculations and structural analysis, complying with FBC -2004, prepared by Sunshine Windows Manufacturing, Inc., dated 12/15/07, signed and sealed by Francisco Hernandez, P.E. Complies with ASTM E1300 -02 D. QUALITY ASSURANCE 1. Miami Dade Building Code Compliance Office (BCCO). E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 05- 1208.02 issued to E.I. DuPont DeNemours & CO., Inc. for "DuPont Butacite PVB. Interlayer." dated January 05, 2006, expiring on December 11, 2010. E -1 Manuel Pe .E. Product Control i i er NOA No. 0: .08 Expiration Date: April 10, 2013 Approval Date: April 10, 2008 Sunshine Windows Manufacturing, Inc. • NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED F. STATEMENTS 1. Statement letter of conformance, dated December 15, 2007, signed and sealed by Francisco Hernandez, P.E. 2. Statement letter of no financial interest, dated December 15, 2007, signed and sealed by Francisco Hernandez, P.E. 3. Laboratory compliance letter for Test Report no. FTL -5331, issued by Fenestration Testing Laboratory, Inc., dated September 21, 2007, signed and sealed by Carlos S. Rionda, P.E. 4. Laboratory compliance letter for Test Report no. FTL -5015, issued by Fenestration Testing Laboratory, Inc., dated August 07, 2007, signed and sealed by Carlos S. Rionda, P.E. G. OTHER 1. None • E -2 Manuel Per Product Control E r NOA No. 08-0107.08 Expiration Date: April 10, 2013 Approval Date: Apr1110, 2008 3 1/8" MAX. y.10 WINDOW HEIGHT II c0 IMPACT GLASS MAX. IMPACT GLASS j 3 1/8" I' MAX. WINDOW WIDTH TYPICAL ELEVATION (XO) 00 {E) 10 "l MAX. GENERAL NOTES: IMPACT HORIZONTAL ROLLER WINDOW. 1.- CONFIGURATIONS OX AND X0 2.- FOR NUMBER OF ANCHORS FOR EACH UNIT SIZE REFER TO DESIGN PRESSURE CHART 3.- REFERENCES: TEST REPORTS FTL -5015 AND FTL -5331. 4.- THIS PRODUCT MEETS THE REQUIREMENTS OF THE 2004 FLORIDA BUILDING CODE 5.- FASTENERS MUST HAVE THEIR OWN NOTICE OF' ACCEPTANCE AND MUST BE MADE OF STAINLESS STEEL OR HAVE ADEQUATE PROTECTION AGAINST CORROSION, PER DIN 50018. ALUMINUM CONTACTING METALS SHALL BE PROPERLY PROTECTED. 6.- GLAZING: 0.340" OVERALL LAMINATED GLASS USING TWO LITES OF 0.125" HEAT STRENGTHENED GLASS WITH A 0.090" INTERLAYER FILM DUPONT BUTACITE PVB, BETWEEN THE TWO UTES OF GLASS. LAMINATED BY TECNOGLASS OR SIMILAR MIAMI- DADE IMPACT RESISTANT SHUTTERS ARE NOT REQUIRED IMPACT RESISTANT WINDOW FALSE MUNTINS (SURFACE APPLIED) MAY BE USED Approved as complying withthe Florida �,.�= Code Dale 117 ./.8 NOA4 .08 Miami Dad c . ' t Control By 3- 1`i -08 FRANCISCO HERNANDEZ FLORIDA PE # 51393 DESIGN PRESSURE CHART - PSF SERIES 1650 ALUMINUM HORIZONTAL SLIDING WINDOW (XO) HEAT STRENGTHENED LAMINATED IMPACT RESISTANT GLASS WINDOW DIMENSION ANCHOR SCHEDULE HURRICANE PROCTECTION IS NOT REQUIRED WIDTH HEIGHT pER HEAD & pER Aye 8 13/4" SILL 3" SILL Er. INT. EXT. INT. STANDARD SIZES 28 1/2" 37" 53 1/8" 74" 26" 3 SHEET 53.33 120.00 80.00 120.00 4 53.33 120.00 80.00 120.00 6 3 53.33 119.30 80.00 119.3 8 53.33 90.0 80.00 90.00 26 1/2" 37" 53 1/8" 74" s 3/8 3 5 53.33 120.0 80.00 120.00 4 53.33 120.0 80.00 120.00 6 53.33 95.50 80.00 95.50 8 53.33 78.90 78.90 78.90 37" 53 1/8' 74" 50 5/8" 4 6 53.33 104.70 80.00 104.70 6 53.33 88.40 80.00 88.40 i 8 53.33 67.30 67.30 67.30 1 37" 53 1/8' 74" 83" 4 7 53.33 88.20 80.00 88.20 6 53.33 75.00 75.00 75.00 8 53.33 62.00 62.00 62.00 MODULAR SIZES 24" 38" 48" 80' 72" 24" 3 3 53.33 120.0 80.00 120.0 4 53.33 120.0 80.00 120.0 5 53.33 120,0 80.00 120.0 6 53.33 120.00 80.00 120.0 7 53.33 90.00 80,00 90.00 24" 38" 48" 80' 72" 38" 3 4 53.33 120.00 80.00 120.0 4 53.33 120.00 80.00 120.0 5 53.33 120.00 80.00 120.0 6 53.33 99.90 80.00 99.90 7 53.33 88.60 80.00 88.60 38" 48" 60" 72" 48" 4 5 53.33 100.40 80.00 100.40 5 53.33 93.90 80.00 93.90 6 53.33 87.00 80.00 87.00 7 53.33 74.30 74.30 74.30 38" 48" 80' 72" 4 53.33 90.00 80.00 90.00 5 53.33 87.00 80.0 87.00 80" 6 7 53.33 83.40 80.0 83.40 7 53.33 67.80 67.80 67.80 3 1/8" MAX. y.10 WINDOW HEIGHT II c0 IMPACT GLASS MAX. IMPACT GLASS j 3 1/8" I' MAX. WINDOW WIDTH TYPICAL ELEVATION (XO) 00 {E) 10 "l MAX. GENERAL NOTES: IMPACT HORIZONTAL ROLLER WINDOW. 1.- CONFIGURATIONS OX AND X0 2.- FOR NUMBER OF ANCHORS FOR EACH UNIT SIZE REFER TO DESIGN PRESSURE CHART 3.- REFERENCES: TEST REPORTS FTL -5015 AND FTL -5331. 4.- THIS PRODUCT MEETS THE REQUIREMENTS OF THE 2004 FLORIDA BUILDING CODE 5.- FASTENERS MUST HAVE THEIR OWN NOTICE OF' ACCEPTANCE AND MUST BE MADE OF STAINLESS STEEL OR HAVE ADEQUATE PROTECTION AGAINST CORROSION, PER DIN 50018. ALUMINUM CONTACTING METALS SHALL BE PROPERLY PROTECTED. 6.- GLAZING: 0.340" OVERALL LAMINATED GLASS USING TWO LITES OF 0.125" HEAT STRENGTHENED GLASS WITH A 0.090" INTERLAYER FILM DUPONT BUTACITE PVB, BETWEEN THE TWO UTES OF GLASS. LAMINATED BY TECNOGLASS OR SIMILAR MIAMI- DADE IMPACT RESISTANT SHUTTERS ARE NOT REQUIRED IMPACT RESISTANT WINDOW FALSE MUNTINS (SURFACE APPLIED) MAY BE USED Approved as complying withthe Florida �,.�= Code Dale 117 ./.8 NOA4 .08 Miami Dad c . ' t Control By 3- 1`i -08 FRANCISCO HERNANDEZ FLORIDA PE # 51393 ............... ............... Sunshine Windo Manufacturing, In) . 1745 W. 33rd Place Hialeah, Florida 3.#012 Ph: (305)384 -9952 Fa:c(305)828 -5118 HORIZONTAL SLIDING WINDOW (XO) IMPACT RESISTANT GLASS Drown Bv: R F Date: 03 -14 -08 Scale 1- Revialon: Revision: DRAWING NO. • HS08 -01 SHEET 1 0 F 7 1 3 1 /8" 7" ' �- •• MAX. J ' MAX. DESIGN PRESSURE CHART - PSF WINDOW HEIGHT _ � , 1 IMPACT GLASS IMPACT GLASS ; " ; F /, . 4 SERIES 1650 ALUMINUM HORIZONTAL SLIDING WINDOW (XO) Sunshine Windows Manufacturing, Inc. nos W. 33rd Place Hialeah. Florida 33012 Ph: (305)384 -9952 Rec(305)828 -5118 { Ci / � ' { p /1; i •,n . -- /a } HEAT STRENGTHENED LAMINATED IMPACT RESISTANT GLASS WINDOW DIMENSION ANCHOR SCHEDULE HURRICANE PROCTECTION IS NOT REQUIRED ) �E 1 FALSE MUNTINS APPLIED) WIDTH HEIGHT PER HEAD & SILL PER JAMB 13/4" SILL 3" SILL EXT. INT. EXT. INT. M �n 1 STANDARD I 74" 38 3/8" 11 6 53.33 90.00 80.00 90.00 (SURFACE MAY BE USED 74" 50 s /8" 11 8 53.33 90.00 80.00 90.00 i 37" 83` 6 9 53.33 90.00 80.00 90.00 3 " ' 7" 531/8" 8 53.33 90.00 80.00 90.00 . MAX. MAX. 74" 11 53.33 85.20 80.00 85.20 WINDOW WIDTH VIN dT G1 AO X 72" 48" 11 7 53.33 90.00 80.00 90.00 48" 60" 7 9 53.33 90.00 80.00 90.00 TYPICAL ELEVATION (X0) 1* cfl V1 t.a F il F V W g V� C :i 60" 9 53.33 90.00 80.00 90.00 72" 11 53.33 90.00 80.00 90.00 GENERAL NOTES: IMPACT HORIZONTAL ROLLER WINDOW. 1.- CONFIGURATIONS OX AND XO 2.- FOR NUMBER OF ANCHORS FOR EACH UNIT SIZE REFER TO DESIGN PRESSURE CHART 3.- REFERENCES: TEST REPORTS FTL -5015 AND FTL -5331. 4.- THIS PRODUCT MEETS THE REQUIREMENTS OF THE 2004 FLORIDA BUILDING CODE 5.- FASTENERS MUST HAVE THEIR OWN NOTICE OF ACCEPTANCE AND MUST BE MADE OF STAINLESS STEEL OR HAVE ADEQUATE PROTECTION AGAINST CORROSION, PER DIN 50018. ALUMINUM CONTACTING METALS SHALL BE PROPERLY PROTECTED. 6.- GLAZING: 0.340" OVERALL LAMINATED GLASS USING TWO LITES OF 0.125" HEAT STRENGTHENED GLASS WITH A 0.090" INTERLAYER FILM DUPONT BUTACITE PVB, BETWEEN THE TWO LITES OF GLASS. LAMINATED BY TECNOGLASS OR SIMILAR Approved as complying with the Florida ' ' ding Code . �" I ,,,Ag NQA# 0 ; + d , Mind Dade Product Control • • , Ey Li 3 -16 -0$ FRANCISCO R 6ANDE Drown, ev R F Date: 03 -14-08 I MUM- DADE IMPACT RESISTANT SHUTTERS ARE NOT REQUIRED scale 1- 2" 1 Revision: IMPACT RESISTANT WINDOW Revision: DRAWING NO. HS08 --01 SHEET 2 of WINDOW HEIGHT E� 20 VERTICAL SECTION HORIZONTAL SECTION VERTICAL SECTION WITH SILL RISER IMPACT RESISTANT WINDOW Approved es complying with the F9osi Code Dare J !D NOM ; -•" .qg Miami Dade Prod Control 0 By *...to-oS FRANCISCO I-IERNANDEZ FLORIDA PE # 51393 ................ Sunshine Windows Manufacturing, Inc. 1745 W. 33rd Ploca Hialeah, Florida 33012 Ph: (305)364 -9952 Fax: (305)826-5116 HORIZONTAL SLIDING WINDOW (XO) IMPACT RESISTANT GLASS Drawn e„: R F Date: 03 -14-08 gems: 1 /2 "==1' Revision: Revision: DRAWING NO. HS08 -01 SHEET 30F7 MATERIAL LIST MATERIAL LIST ITEM # PART # REQD. DESCRIPTION MATERIAL ITEM # PART # REQD. DESCRIPTION MATERIAL 1 SW -019 1 FRAME HEAD 6063 -T5 13 SW -016 1 MOVING SIDE RAIL 6063 -T5 2 SW -019 1 FRAME SILL 6063 -T5 14 SW3257 AS RQD WEATHER STRIP BULB VINYL Sunshine Windows Manufacturing, Inc. 1745 W. 33rd Place Hialeah, Florida 33012 Ph: (305)364 -9952 Farc(305)828 -5118 3 SWxxx21 1 INSERT TRACK 6063 -T5 15 SW -667 AS RQD LATCH ZINC 5 SW -012 2 SLIDER TOP /BOTTOM RAIL 6063 -T5 16 SW -S10 2 /SILL RETICULATED FILTER FOAM 6 SW3019 AS RQD FIN SEAL PILE FELT 17 SW40771 1 SILL RISER 6063 -T5 8 SW321W 2 WHEEL BRASS 18 SW -014 1 JAMB TO FIXED PANEL 6083 -T5 O C (/) 9 SW -017 1 MOVING MEETING RAIL 6063 -T5 19 - AS RQD SILICONE PEC. -895 OR SIMILAR 10 SW40111 1 FIXED MEETING RAIL 6063 -T5 20 SW -101 AS RQD IMPACT GLAZING BEAD 6063 -T6 11 SW -AS AS RQD ASSEMBLY SCREWS # 8 X 1" SMS. 21 SW -STL 1 3/8" X 3/4" FLAT BAR STEEL 12 SW -013 1 JAMB TO MOVING PANEL 6063 -T5 22 SW -AS 4 ASSEMBLY SCREWS # 8 X 2 1/2" SMS. 0.812 1.625 ----) 394 N T0.0 5 0 2.125 1 1.875 �Li _F 0.050 RAIL 1.250 0.6137 r I 0.062 1.... 1.750 1.250 1.437 0.398 V 0.812— GLAZING BEAD SW-018 T5 63 1.312 V c_, FIXED MEETING RAIL SW -40111 6063 -T5 MOVING MEETING SW -017 8063 -T5 FRAME JAMB TO FIXED PANEL SW -014 6063 -T5 2.077 ---I JAMB TO MOVING PANEL SW -013 6063 -T5 I� 1.00 V1 E"I U i Q W Q C! ►F'Cli 0.078 Approved as complying with thej Florida ., oil . ' , Code Data • ' 0 /,' 0.062 1.8750 t 0.592 1.750 2.7 1.5090 3.062 1 0.050 0.750 -� SILL _TLI -d 0 810 �-- SUDER TOP AND BOTTOM RAIL SW -012 6063 -T5 --0-I 1.0000 1-.- 2.00 INSERT TRACK SW -xxx21 6083 -T5 NOA# 0 Mr'15k,..: FRAME HEAD AND SW -019 6063 -T5 MOVING SIDE RAIL SW -016 6063 -T5 SILL RISER SW -40771 6063 -T5 Miami Dade .. , .- carol Dead =. By �/: • '- 1 IMPACT RESISTANT WINDOW Dawn w: RF Date: 03 -14 -08 sage: 1/2"=1' Revision: Rwtaton: ''L°6t 4,,ii,o8 ORIDAC PE # 51 93 DRAWING 140. HS08 -01 SHEET 4 OF 7 TYPICAL ANCHORS TYPICAL ANCHORS 2 1/2" MIN. 2 1/2" MIN. 1 1/2" MIN. PENETRATION INTO WOOD. .. 1 4" TAPCONS 1 1 4" MIN. EMBEDMENT 1/4" SMS / / INTO MASONRY THROUGH 1" BY WOOD BUCK INTO MASONRY THROUGH 1" BY WOOD BUCK + (FOR MAX. ANCHOR SPACING AND NUMBER :• a a ' • a ° * "' a'•• E a h ° a °.. (FOR MAX. ANCHOR SPACING AND NUMBER OF ANCHORS REFER TO DESIGN PRESSURE CHART) _ OF ANCHORS REFER TO DESIGN PRESSURE CHART) Sunshine Windows Manufacturing, Inc. 1ii0l 5 .133rd Place 33012 Rh: (308)384 -9982 Fa x:(305)828-5118 �;• ,.. F.� . ,,,•;.. .1 ti• • • . 2 BY WOOD BUCK 1 ;. / —iii Jim el. 35 .:-...-6 )lam W N s ) t I 1 r DETAIL A ATTACHMENT TO MASONRY DETAIL B ATTACHMENT TO WOOD TYPICAL ANCHORS 1/4" SMS. THROUGH METAL (FOR MAX. ANCHOR SPACING AND NUMBER OF ANCHORS REFER TO DESIGN PRESSURE CHART) Q+ ►L SLIDING W1NDOV i! 0 Approved as complying with the Florida : , + Code, Date r -i 10 r i.. Et) °Llil 4t CI) a 0 H �� _ t ��� i f i 1 1 NOA# • ;..:ria -..'; Miami Pr, ■ . Control By r1L_.- _ ! ;- dr 1 111,17. / 3 —m_o8 ORIDACDPE HERNANDEZ # 51393 DETAIL C ATTACHMENT TO METAL STRUCTURE DETAIL (STEEL OR ALUM. 1/8" MIN. THICKNESS) TYPICAL HEAD SECTIONS Drown Dv: R F Date: 03 -14 -08 Scale: 1— 22"=1 Revt5Ion: Revision: DRAWING N0. HS08 -01 IMPACT RESISTANT WINDOW SHEET 5 OF 7 • d' A 2 1/2" MIN. TYPICAL ANCHORS 2 1/2" MIN. -1/4" TAPCONS 1 1/4" MIN. EMBEDMENT INTO MASONRY (FOR MAX. ANCHOR SPACING AND NUMBER OF ANCHORS REFER TO DESIGN PRESSURE CHART) DETAIL D ATTACHMENT TO PRE -CAST SILL TYPICAL ANCHORS 2" BY WOOD BUCK 1/4" SMS 1 1/2" MIN. PENETRATION INTO WOOD. (FOR MAX. ANCHOR SPACING AND NUMBER OF ANCHORS REFER TO DESIGN PRESSURE CHART) DETAIL F ATTACHMENT TO WOOD 2 1/2" MIN. DETAIL E 3/4" MAX. NON — SHRINK GROUT OR 1' BY WOOD BUCK • 4 TYPICAL ANCHORS 1/4" TAPCONS 1 1/4" MIN. EMBEDMENT INTO MASONRY THROUGH 1" BY WOOD BUCK OR NON SHRINK NON METALLIC GROUT (FOR MAX. ANCHOR SPACING AND NUMBER OF ANCHORS REFER TO DESIGN PRESSURE CHART) ATTACHMENT TO MASONRY TYPICAL ANCHORS SMS THROUGH METAL. (FOR MAX. ANCHOR SPACING AND NUMBER OF ANCHORS REFER TO DESIGN PRESSURE CHART) DETAIL G ATTACHMENT TO METAL STRUCTURE (STEEL OR ALUM. 1/8" MIN. THICKNESS) TYPICAL SILL SECTIONS IMPACT RESISTANT WINDOW Approved as complying with the Florida u' din,, Opd_ Date �,� Z NOAH • i 'Natal Dade . Di • • By —16. -00 FRANCISCO HERNANDEZ FLORIDA PE # 51393 El • • Sunshine Windows Manufacturing, Inc. 1745 W. 33rd Place Hialeah, Florida 33012 Ph: (305)364 -9952 Fax:(305)828 -5118 SERIES 1650 ALUMINUM HORIZONTAL SLIDING WINDOW (XO) IMPACT RESISTANT GLASS Drawn Br. RF Dote: 03 -14-08 snobs: 1/2"=1° Revision: Wean: n: DRAWING NO. HS08 -01 SHEET 6OF7 1 /4" MAX. SHIM SPACE II4MIN. -_ ,,,. 11;; ;J;uu:;;;::: ; ;r,:t- .71M.'-'511.1 f 1 00 1 1 /4" TYPICAL ANCHORS 1/4" TAPCONS 1 1/4" MIN. EMBEDMENT INTO MASONRY THROUGH 1" BY WOOD BUCK OR NON SHRINK NON METALLIC GROUT • a (FOR MAX. ANCHOR SPACING AND NUMBER OF ANCHORS REFER TO DESIGN PRESSURE CHART) DETAIL H ATTACHMENT TO MASONRY TYPICAL ANCHORS 1/4° SMS THROUGH METAL (FOR MAX. ANCHOR SPACING AND NUMBER OF ANCHORS REFER TO DESIGN PRESSURE CHART) MIAMI DADE COUNTY APROVED ULUON ATTACHMENT TO MULLIONS DETAIL 2" BY WOOD BUCK TYPICAL ANCHORS 1/4" SMS 1 1/2" MIN. PENETRATION INTO WOOD. (FOR MAX. ANCHOR SPACING AND NUMBER OF ANCHORS REFER TO DESIGN PRESSURE CHART) DETAIL I ATTACHMENT TO WOOD DETAIL GLAZING DETAIL 0.090" DUPONT BUTACITE PVB OR SIMILAR 1/8" HEAT 1/8" HEAT STRENGTHENED STRENGTHENED 3/8" GLASS BITE (TIPICAL) 31 10 4411110 SIUCONE PECORA 895 OR SIMILAR GLAZING: 0.340" OVERALL LAMINATED GLASS USING TWO LITES OF 0.125" HEAT STRENGTHENED GLASS WITH A 0.090" INTERIAYER FILM DUPONT BUTACITE PVB, BETWEEN THE TWO UTES OF GLASS. LAMINATED BY TECNOGLASS OR SIMILAR TYPICAL JAMB SECTIONS IMPACT RESISTANT WINDOW 1/4" MAX. SHIM SPACE TYPICAL ANCHORS 1/4" SMS. THROUGH METAL (FOR MAX. ANCHOR SPACING AND NUMBER OF ANCHORS REFER TO DESIGN PRESSURE CHART) DETAIL J ATTACHMENT TO METAL STRUCTURE DETAIL (STEEL OR ALUM. 1/8° MIN, THICKNESS) Approved as complying with the Florida : , ..Cpl Date ' ` 0 Pty NO. # 49 Miaini Dade Product Control Div' . By 14--0,6+ FRANCISCO HERNANDEZ FLORIDA PE # 51393 1PM Sunshine Windows Manufacturing, Inc. 1745 W. 33rd Place Hialeah, Florida 33012 Ph: (305)384 -9952 Fmc(305)828 -5118 SERIES 1650 ALUMINUM HORIZONTAL SLIDING WINDOW (XO) IMPACT RESISTANT GLASS Drawn Bv: RF Dote: 03 -14 -08 Seale: 1/2 " =1' RevWen: Revision: DRAWING NO. HS08 -01 SHEET 70F7 r • MIA M I•DADE BUILDING CODE COMPLIANCE OFFICE (BCCO) PRODUCT CONTROL DIVISION NOTICE OF ACCEPTANCE (NOA) MIAMI -DARE COUNTY, FLORIDA METRO -DADE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 MIAMI, FLORIDA 33130 -1563 (305) 375 -2901 FAX (305) 375 -2908 Sunshine Windows Manufacturing, Inc. 1745 W. 33rd Place Hialeah, Florida 33012 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by Miami -Dade County Product Control Division and accepted by the Board of Rules and Appeals (BORA) to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Division that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Series 2001 Aluminum French Door Impact Resistant. APPROVAL DOCUMENT: Drawing No. FD08 -1, titled "Series 2001 Aluminum French Door Impact Resistant ", sheets 1 through 3 of 3, prepared by the manufacturer, dated 04/02/08 with no revisions signed and sealed by Francisco Hernandez, P.E., bearing the Miami -Dade County Product Control Renewal stamp with the Notice of Acceptance number and expiration date by the Miami -Dade County Product Control Division. MISSILE IMPACT RATING: Large and Small Missile Impact LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA # 02- 1104.03 consists of this page 1, evidence page 1, as well as approval document mentioned above. The submitted documentation was reviewed by Mohammed Iqbal Shaikh, P.E. NOA No 08-0417.05 Expiration Date: May 08, 2013 Approval Date: May 22, 2008 Page 1 MIAMI -DADE COUNTY APPROVED Dy1y7/p° • Sunshine Windows Manufacturing, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED A. DRAWINGS 1. Drawing No. FD08 -01, titled "Series 2001 Aluminum French Door Impact Resistance ", sheets 1 through 3of 3, prepared by the manufacturer, dated 04 /02/08 with no revision, signed and sealed by Francisco Hernandez, P.E. B. TESTS ( Submitted Under NOA # 2- 1104.03) 1. Test reports on 1) Air Infiltration Test, per FBC, TAS 202 -94 2) Uniform Static Air Pressure Test, Loading per FBC, TAS 20294 3) Water Resistance Test, per FBC, TAS 202 -94 4) Large Missile Impact Test per FBC, TAS 201 -94 5) Cyclic Wind Pressure Loading per FBC, TAS 203 -94 6) Forced Entry Test, per FBC 2411 3.2.1 and TAS 202 -94 Along with marked -up drawings and installation diagram of an aluminum swinging glass door, prepared by Fenestration Testing Laboratory, Inc., Test Report No. 3399, dated 07/24/02, signed and sealed by Late Gilbert Diamond, P.E., reviewed by J. O. Chan, P. E. • C. CALCULATIONS 1. Anchor Calculations and structural analysis, prepared by Francisco Hernandez, PE, dated 03/31/08 signed and sealed by F. Hernandez, P.E. D. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 06- 0216.06 issued to Solutia, Inc. for "Saflex III G clear and colored interlayer", expiring on 05/21/11 2. . Die drawings prepared by Alcan ExtrusionsAWC -36, 37, 38, 39, 47 & 57, dated 2003. E. STATEMENTS 1. No Interest Letter signed and sealed by Francisco Hernandez, PE. on April 02, 2008, 2. Code Compliance letter signed and sealed by Francisco Hernandez PE, on April 02,2008 3. Test Compliance letter issued by Fenestration Testing Laboratory, Inc on 08/16/02 signed and sealed by J. Chan, PE.(Submitted Under NOA# 02- 1104.03) F. OTHER 1. NOA # 02- 1104.03 E -1 Mohammed Iqbal Shaikh. P.E. Senior Building Code Compliance Specialist NOA No. 08- 0417.05 Expiration Date: May 08, 2008 Approval Date: May 22, 2003 DOOR HEIGHT FOR ANCHOR OPTIONS AND NUMBER OF ANCHORS SEE NOTE #1 AND DESIGN PRESSURES CHART OF THIS SHEET. FOR DETAILS SEE SECTIONS SHOWN ON SHEETS 2 OF 3 AND 3 OF 3. 50 10" MAX. 37" MAX. DOOR WIDTH r".1 X DOOR LEAF WIDTH (NOMINAL) DOOR LEAF ANCHORS PER HEAD AND SILL DOOR HEIGHT (NOMINAL) DOOR LEAF ANCHORS PER JAMB I1 NEG. 3' -0" 1 1 8 70.0 26 1/8" 3 MAX. — DAYLIGHT // 3' -0" co M co E 7 _ 0/ c.-c- II 1 I I I 70.0 26 1/8" _ 37" MAX. DOOR WIDTH r".1 X MAX MAX. ELEVATIONS MAX. 72" MAX. DOOR WIDTH 5" AX MIAMI- DADE IMPACT RESISTANT SHUTTERS ARE NOT REQUIRED DESIGN PRESSURES CHART- PSF DOOR LEAF WIDTH (NOMINAL) DOOR LEAF ANCHORS PER HEAD AND SILL DOOR HEIGHT (NOMINAL) DOOR LEAF ANCHORS PER JAMB POS. NEG. 3' -0" 4 8' -0" 8 70.0 70.0 2' -6" 3 - 70.0 70.0 3' -0" 4 6' -8" 7 70.0 1 l _ f 26 1/8" 70.0 26 1/8" _ MAX. DAYLIGHT MAX. DAYLIGHT / a20 rn c STRIKE O PLATES / co J 1..._. • N N -N. t 0 MAX MAX. ELEVATIONS MAX. 72" MAX. DOOR WIDTH 5" AX MIAMI- DADE IMPACT RESISTANT SHUTTERS ARE NOT REQUIRED DESIGN PRESSURES CHART- PSF DOOR LEAF WIDTH (NOMINAL) DOOR LEAF ANCHORS PER HEAD AND SILL DOOR HEIGHT (NOMINAL) DOOR LEAF ANCHORS PER JAMB POS. NEG. 3' -0" 4 8' -0" 8 70.0 70.0 2' -6" 3 - 70.0 70.0 3' -0" 4 6' -8" 7 70.0 70.0 — 2' -6" - 3 70.0 70.0 NOTES: 1. ANCHOR OPTIONS AND NUMBER OF ANCHORS: 1/4" ELCO TAPCONS WITH 1 1/2" MIN. EMBEDMENT INTO CONCRETE BLOCK OR #14 S.M.S. WITH 1 1/2" MIN. EMBEDMENT INTO 28Y. WOOD BUCK OR #14 S.M.S. X 1 1/2" IN METAL FOR NUMBER OF ANCHORS FOR EACH DOOR UNIT SIZE REFER TO DESIGN PRESSURES CHART. 2. FLUSH BOLTS. ALL DOOR FLUSH BOLTS SHALL BE ENGAGED IN ORDER TO ACHIEVE DESIGN PRESSURES SHOWN ABOVE. 3. GLAZING. 5/16" OVERALL LAMINATED GLASS MADE OF TWO LITES OF 1/8" HEAT STRENGTHENED GLASS WITH A 0.090" INNER LAYER FILM SAFLEX- KEEPSAFE BY SOLUTIA INC. GLAZING PENETRATION 0.533 ". 4. COLONIAL MUNTINS CAN BE APPLIED. 5. FRAME CORNERS CONSIST OF BUTT JOINTS FASTENED WITH (2) #10 X 1" PAN HEAD SHEET METAL SCREWS. 6. SEALANT AROUND PERIMETER OF DEAD BOLT, HANDLE, STRIKE PLATES, FLUSH BOLTS, FRAME, PANEL, ETC. 7. REFERENCE TEST REPORT FFL -3399. 8. THIS PRODUCT MEETS THE REQUIREMENTS OF THE 2004 FLORIDA BUILDING CODE. f ®( PROI7T], a R.1?R'k?t'1'!s t ur 't!ys:yi:,,T with t't;.+ r'r:tir_l4 dAcc,r,ti•ri ' No Qg"' OW es • Evsairr Dr.to 4 -2 -0g FRANCISCO HERNANDEZ FL. PE # 51393 Sunshine Windows Manufacturing, Inc. 1745 W. 33rd Plate Hialeah, Florida 33012 Ph: (305)364 -9952 Fox:(305)828 -5118 Drawn By: RF Date: 04/02/08 fib: NTS Revision: Revision: DRAWING NO. FD08 -01 SHEET 1 OF 3 v va •p va ANCHORS @6° FROM CORNERS AND THE REST @12° O.C. MAX. FOR ANCHOR OPTIONS AND NUMBER OF ANCHORS SEE NOTE #1 AND DESIGN PRESSURE CHART ON SHEET 1 OF 3. (TYPICAL FOR DOOR JAMBS) 1BY OR 2BY WOOD BUCK BY OTHERS SHALL WITHSTAND ALL GLAZING SYSTEM LOADS (TYPICAL FOR ALL WOOD BUCKS) ANCHORS ®6° FROM CORNERS AND THE REST 4/112" O.C. MAX. FOR ANCHOR OPTIONS AND NUMBER OF ANCHORS SEE NOTE #1 AND DESIGN OPRESSURE CHART ON SHEET 1 OF 3. 4 (TYPICAL FOR DOOR JAMBS) 0 4S_.' HORIZONTAL SECTIONS CMU WALL GLAZING DETAIL 0.090° SAFLEX— KEEPSAFE BY SOLUTIA 1/8° HEAT 1/8° HEAT STRENGTHENED STRENGTHENED 1/2° GLASS BITE (MINIMUM) PERIMETER TRIM (OPTIONAL) SILICONE W CORNING 995/ PECORA 895 Sunshine Windows Manufacturing, Inc. 1745 W. 33rd Place Hialeah, Florida 33012 Ph: (305)384 -9952 Fa(305)828 -5118 SERIES 2001 AL o aE o z w Drown ey: RF Date: 04 -0 —08 Scale: 1/2"=1' Revhdom. Revlaion: DRAWING NO. FD08 -01 SHEET 2 OF 3 PROOJC:' R.Z.7...1'w:_I` as f i q with ti;, :7ioric14 endt'. Ateeptc;sse No 0 ; - 0 I}./ Expiration x,, - irit BY hitiamiENdefthutamtmd Division a A J III IF IIP'l 4- 2_03 FRANCISCO H ERNNW EZ FL. PE # 51393 Sunshine Windows Manufacturing, Inc. 1745 W. 33rd Place Hialeah, Florida 33012 Ph: (305)384 -9952 Fa(305)828 -5118 SERIES 2001 AL o aE o z w Drown ey: RF Date: 04 -0 —08 Scale: 1/2"=1' Revhdom. Revlaion: DRAWING NO. FD08 -01 SHEET 2 OF 3 1BY OR 28Y WOOD BUCK BY OTHERS SHILL WITHSTAND ALL GLAZING SYSTEM LOADS (TYPICAL FOR ALL WOOD BUCKS) a • `$ Qai. • C • V IMPACT GLASS: SEE NOTE #3 ON SHEET 1 OF 3 AND GLAZING DETAIL SHOWN IN SHEET 2 OF 3. STRUCTURAL SILICONE DOW CORNING OR SIMILAR ANCHORS 05" FROM CORNERS AND THE REST 010" 0.C. MAX. FOR ANCHOR OPTIONS AND NUMBER OF ANCHORS SEE NOTE #1 AND DESIGN PRESSURE CHART ON SHEET 1 OF 3. (TYPICAL FOR HEAD AND SILL) VERTICAL SECTION MATERIAL LIST ITEM # PART # REQD. DESCRIPTION MATERIAL 1 SW -38 1 FRENCH DOOR HEAD 6063 —T6 2 SW -39 4 FRENCH DOOR TOP AND BOTTOM RAIL 6063 —T6 3 SW -36 4 FRENCH DOOR VERTICAL STILE 6063 —T6 4 SW -37 2 FRENCH DOOR JAMB 6063 —T6 5 SW -40928 (4 ") 1 PER ANCHOR FLAT FILL COVER 6063 —T5 6 SW -40 1 FRENCH DOOR SILL (MILL FINISH) 6063 —T6 7 SW -47 1 FRENCH DOOR ADAPTER 6063 —T5 8 SW -3332 AS REQ'D FIN PILE WEATHER STRIP (VYNIL BULB) POLYPROPYLENE 9 SW -57 3 PER LEAF 8" BUTT HINGE 6063 T5 10 SILICONE AS REQD DOW CORNING 995/PECORA 895 SILICONE 11 SW —L1 1 LOCK (LATCH) METAL 12 SW —L2 1 YALE NEW TRADITIONS' 800 SERIES DEAD BOLT LOCK, KEY OPERATED ON THE EXTERIOR AND THUMB TURN ON THE INTERIOR METAL 13 SW—F8 2 PER LEAF SERIES 2510 CONCEALED FLUSH BOLT BY REGENT METAL 14 SCREWS AS —REQ'D # 10 X 1" SMS 15 SCREWS AS —REQD # 10 X 1 1/2" SMS 16 SW -30 AS —REQD APPLIED PERIMETER TRIM 6063 —T5 17 SCREWS AS —REQ'D # 8 X 1 /2" SMS 18 SW —H 1 SURFACE MOUNT HANDLE METAL OFD HEAD (SW -38) .078" 5.00" FD JAMB (SW -37) 0 FD ADAPTER(SW -47) 0 FD TOP & BOTTOM RAIL (SW -39) o 4.375 FD VERTICAL STILE (SW -36 657 if PERIMETER TRIM 3.50" J OFD FLAT FILL COVER (SW- 409280) 1.908" FD HINGE (SW -57) 5.00" FD SILL (SW -40) ... v > i ':; •, , ow Florida • A.,• 1.;•, - ,d;1-,0 0 E.F: t:s an I: 1e A F Ni Division kp aF.cz t Contra •0r 3 / i 'If lit 4. 2-08 FRANCISCO HERNANDEZ FL PE # 51393 Sunshine Windows Manufacturing, Inc. 1745 W. 33rd Place Htobah, Florida 33012 Ph: (305)364-9952 Fac(305)828 -5118 1 g:8 , et A 41 O x px N Z cil M fr.' Drown Dv: RF Date: 04 -02 -08 Saute: 1 /2"=1 ' Revision: Revision: DRAWING NO. FDOS -01 SHEET 3 OF 3