PLC-11-12
Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Inspection Number: INSP - 154624 Scheduled Inspection Date: August 03, 2011 Inspector: Hernandez, Rafael Permit Number: PLC- 1 -11 -12 Owner: , BARRY UNIVERSITY Job Address: 11300 NE 2 Avenue Andreas Buildin Miami Shores, FL 33138 -0000 Project: BARRY UNIVERSITY Contractor: MARLIN PLUMBING OF MIAMI INC Permit Type: Plumbing - Commercial Inspection Type: Final Work Classification: Addition /Alteration Phone Number Parcel Number 1121360010160 -21 Phone: 305 -652 -6108 Building Department Comments RUN NEW 3" SANITARY W/ ELECTOR PUMP FOR EXISTING BATHROOM TO EXSTING 4" SANITARY DRAIN AND RECONNECTING 1 -3 COMPARTMENT SINK AND 1 HAND SINK EXISTING Passed Failed Correction Needed Re- Inspection Fee No Additional Inspections can be scheduled until re- inspection fee is paid. Inspector Comments August 02, 2011 For Inspections please call: (305)762 -4949 Page 4 of 47 0'44 Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 INSPECTION'S PHONE NUMBER: (305) 762.4949 BUILDING Permit No. PERMIT APPLICATION Master Permit No. FBC 20 =1 57=-71 Permit Type: PLUMBING jj (( C/ OWNER: Name (Fee Simple Titleholder): COQ 1(r U ► ✓Q (Si '1"�/ p Phone #: ,� � -89'7- 1 � S T Address: US /Af e a AVE- City: M i a,a i Sh cy-e s State: FL Zip: 33 % (4 Tenant/Lessee Name: Phone#: Email: JOB ADDRESS: 113 Old Ai E 2, d City: Miami Shores Folio/Parcel #: I I- a13(o- CCU 1 -01 (pO County: Miami Dade Zip: 331401 Ls the Building Historically Designated: Yes NO Flood Zone: CONTRACTOR: Company Name: May 61 fit) U M 1,0 t r-1,5 O 4t MitipA470 Phone #: 5)5-C$2 - 303 / Address: aD I LI S N E up Pl a ea_ City: AI, mg' a d4 i IB ea. ail f State: F1_ Zip: 331 '] 6/ Qualifier Name: Ed tt) a,Y d W & t 1.1 e r Phone #:.365 -0 5,2 -3031 State Certification or Registration #: C Fa 0 q 0 a? / vZ Certificate of Competency #: Contact Phone#: 366-6,5.2- 3e) 3 Email Address: m ad i Yt' �i pion" to i r\5 c ac) Z. !V X71 DESIGNER: Architect/Engineer: \.J Phone#: Value of Work for this Permit: $ '7f Fie5-d Square/Linear Footage of Work: Type of Work: ❑Address Alteration New ❑Repair/Replace UDemolition Description of Work: QUA) Piety 3`' t.✓/ jeG7r POOP For E-e,s r,may P 44 0.0044 - -to exts +(my l 3 *. A" DRQ /N,. # ud 4e0APJ l')9 /- 8CC)arpsi�l� c td excsh j ******** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Fees************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Submittal Fee $ --) - (: Permit Fee $ O 7 5' . — CCF $ CO /CC $ Scanning Fee $ Radon n Fee $ DBPR $ Bond $ Notary $ Training/Education Fee $ Technology Fee $ • Double Fee $ Structural Review $ TOTAL FEE NOW DUE $ 2- 0 Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDTTIONERS, ETC OWNER'S AIl')AVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved: a reinspection fee will be charged. Signature Owner or Agent The foregoing instrument was acknowledged before me this day ofJ N • , 20 � , by BRAGS teDVAZDS who is personally known to me or who has produced As identification and who did take an oath. NOTARY PUBLIC: Sign: Print: My Commission Expire Signature La/,Q %UigkW v Contractor The foregoing instrument was acknowledged before me this / �o day of Deezt4420 lU , by Edt rd , who is personally known to me or who has produced as identification and who did take an oath. NOTARY PUBLIC: Print: My Commission Expire �•_ ,,r MY COMMISSION 4 DD 943806 EXPIRES: December 6, 2013 ' ' Bonded Thru Notary Public Undenvrfters * * * * ** * * * * * * * * * * * * * * * * * * * * ** ************************************************ *************m** * ** *** * * **** * ** APPROVED BY -7 `J// Plans Examiner Zoning Structural Review Clerk (Revised 07 /10/07)(Revised 06 /10/2009)(Revised 3/15/09) NOTICE OF COMMENCEMENT A RECORDED COPY MUST BE POSTED ON THE JOB SITE AT TIME OF RRST INSPECTION PERMIT NO. TAX FOLIO NO. it* ,ZOO -017 -17 0 STATE OF FLORIDA: COUNTY OF MIAMI -DADE: THE UNDERSIGNED hereby gives notice that improvements will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information Is provided in this Notice of Commencement. 1 111111 1111111111 11111 1111 1 111111111111111111 C :isH 2011 Rrep 1 1689s 0 OR Bk 27594 Ps 1633; (fps) RECORDED 02 {22/011 12:23:30 HARVEY RUiflNr CLERK OF COURT MIAMI. -DADE C©UNTYr FLORIDA LAST PAGE QG c� Space above reserved for use of recording office 1. Legal description of property and street/address: 6 71 l �/6 7 O J7 t t Mew 2. Description of improvement: Dal; Y1 P 3. Owner(s) name and address• Interest in property: Name and address of fee simple titleholder. 4. Contr c s name address and phone number: �Y ltl�. Qi u n r-191, IGt 6r-t Qs4l a i►c. �/ �{S Ale- C,, 5. Surety: (Payment bond required by owner from contractor, if any) Name, address and phone number: Amount of bond $ 6. Lenders name and address: 7. Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)7., Florida Statutes, Name, address and phone number: et.. d-1 dOS / f'1Erziramr- " r Ali 8. In addition to himself, Owners designates the following person(s) to receive a copy of the Uenor s Notice as provided in Section 713.13(1)(b), Florida Statutes. Name, address and phone number: 9. Expiration date of this Notice of Commencement (the ecptratlot. date Is 1 year from the date of recording unless a differelt.date Is specitied) WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER .713, PART 1, SECTION 713.13. FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR . IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING Y.UR N J CE OF COMMENCEMENT Signature(s) Prepared y, !►J : W . n� =, s Authorized Officer/Director/Partner/Manager ared By -lc-d 0'54 i� eeY Print Name ' % ���;��[ !fw . Print Name "Melia 5n, flotecreairf Title/Office Title/Office a co Il4u.✓rr~.ga4/' STATE OF FLORIDA G COUNTY OF MIAMI -DADE The foregoing instillment was acknowledged before me this 1 % day of , aobtact. rH_ : 2°11 . By_1LL� P�lrq .COS . O ❑.Individua ly, or a as. for Personally known, or arproduced the following type of identifi on: b L to - ?.3 - tee • ?O$ O Signature of Notary Public: Print Name: `True re.5cr_ A ee.ifeer (SEAL) VERIFICATION PURSUANT TO SECTION 92,525. FLORIDA STATUTES Under penalties of perjury, I declare that I have read the foregoing and that the facts stated in it are true, to the best of my knowledge and belief. SIgnature(s) of Owner(s) or Owner(s)`s Authorized Officer/Director/Partner/Manager By By 173.01_62 PAGE 3 3/10 STATE OF FLORIDA, COUNTY OF DADE • HEREBY CERTiFY•thaf this rs aL.ku.copy of the ?rrginal filed in�tgq15 office on ay of h ,AD20 \. nd and Official Seal. CLER of Circuit and County Courts D.C. iffi PROPOSAL MARLIN PLUMBING OF NIIAMI, INC. 20145 N.E.16th PLACE, NORTH MIAMI BEACH, FL 33179 (305) 652 -3031 fax (305) 652 -3135 PROPOSAL SUBMITTED TO Name: Barry University Street: 11300 N.E. 2 AVENUE Miami Shores, FL 33161 Phone: 305- 899 -3785 Fax: 305- 899 -3058 WORK TO BE PERFORMED AT Name: Andreas Park Street: 11300 NE 2 Avenue Miami Shores, FL 33161 Phone: Fax: We hereby propose to furnish the materials and perform the labor necessary for the completion of: Marlin Plumbing to supply and install Simplex System with Plaster Trap on existing Three Compartment Sink Outlet. Marlin Plumbing to tie in Drains from existing 1- Bathroom, 1 -Three Compartment Sink and 1 -Hand Sink. Note Sink will be moved to rear of building. Marlin Plumbing to run approximately 340ft of tin sch40 PVC pipe and fittings from Simplex Lift Station to 4in Main on North side of building. Marlin Plumbing to install approximately 75 Liner Feet of Sod. Marlin Plumbing to supply permit for scope of work mentioned above. Note any deviations from scope of work mentioned above will be done at time and materials. Marlin Plumbing not responsible for any permit fines or fees. Electrical to be done by other All Material and Workmanship is Guaranteed for One (1) Year starting from Completion date. Note: Marlin Plumbing will not be responsible for any underground water pipes, sprinkler lines, gas or electric lines while doing any trenching. If needed, Marlin will call for location services to mark services. All materials and workmanship is guaranteed for one (1) year from the completion date of the contract to be as specified, and the above work to be performed in accordance with the drawings and specifications submitted for the above work and completed in a workmanlike manner for the sum of $7,800.00 *In the event that the customer fails to make any payments to Marlin Plumbing in accordance with the terms and conditions of this agreement, Marlin Plumbing shall be entitled to all reasonable attorneys fees on collection and/or litigation or other court proceeding including attorney's fees on appeal. Respectfully submitted: Marlin Plumbing of Miami, Inc. By: Raul Bringas Date: 11/22/10 ACCEPTANCE OF PROPOSAL The above price, specifications, and conditions are satisfactory and are hereby accepted. You are authorized to do the work as specified. Payments will be made as outlined above. Any alteration or deviation from above specifications involving extra costs will be executed only upon written order and will become an extra charge over and above the estimate. All agreements are contingent upon strikes, accidents or delays beyond our control. Date: Signature: Date: Signature: marlinpropdoc /forml /1998 A?, e C `p NUiYegB �; 'IUIIAMI"DAI;DE `:AX:COLL E {1 F01W FL . 1'St F?IF OOR h^; +MIAMI, FL 3a 2010 LOCAL :BUSINESS TAX RECEIPT. MIAMI-DADE COUNTY ts STATE.OF FLORIDA--' I r7G IRES. Ss T 30 20x11 MUST`BEYDISpL a D AT LA O BUSINEB PURSUANTIO COUNTY BI7171 I NAP ERI;1- ART. THIS IS NOT A BILL — DO NOT PAY RENEWAL RECEIPT NO 2627/0-8 STATE* CFC048292 250346 -5 • BUSINESS NAME / LOCATION MARLIN PLUMBING OF MIAMI INC 20145 NE 16 PL 33179 UNIN DADE COUNTY OWNER MARLIN PLUMBI Sec. Type of Business THIS ' IS ' ONLY6A !mirth' LMBI NG BUSINESS TAX - RECEIPT. IT GOES NOT PERMIT THE HOLDER TO VIOLATE ANY EXISTING RP ON " THE - COUNTY.OR CITIES. NOR DOES IT EXEMPT THE HOLDER FROM ANY OTHER PERMIT OR LICENSE REQUIRED BY LAW. THIS IS NOT A CERTIFICATION OF THE HOLDER'S QUALIFICA- TIONS. PAYMENT RECEIVED MIAMI -DADE COUNTYTAX CoJ TOR: - 09/15/2010 • 09010199001 000075.00 SEE OTHER SIDE FIRST -CLASS U.S. POSTAGE PAID MIAMI, FL PERMIT NO. 231 NG OF MIAMI INC WORKER /S CONTRACTOR 1 —DO- NOT - FORWARD MARLIN PLUMBING OF MIAMI INC EDWARD WALKER 20145 NE 16 PL MIAMI FL 33179 itsl} tttiitttt���ttt��t�tttt�t��tstftt�afl�titt�attsltit�t96 t�1 ACORD CERTIFICATE OF LIABILITY INSURANCE DATE (MM/DD/YYYY) 12/16/2010 PRODUCER (954) 724 -7000 FAX: (954) 724 -7024 Keyes Coverage, Inc. 5900 Hiatus Road Tamarac FL 33321 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. INSURERS AFFORDING COVERAGE NAIC # INSURED Fax # 305 652 3135 Marlin Plumbing of Miami, Inc. 20145 N.E. 16th Place Miami COVERAGES FL 33179 INSURER A: Hartford Fire Insurance Co 19682 INSURER B: Bridgefield Employers Ins Co 10701x INSURER C: INSURER D: INSURER E: THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OFSUCH POLICIES. AGGREGATE LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR LTR ADD'L NSRD TYPE OF INSURANCE POLICY NUMBER POUCYEFFECTIVE DATE IMM/DD/YYYYI POLICY EXPIRATION DATE (MM/DD/YYYYI OMITS A GENERALLIABIUTY X COMMERCIAL GENERAL LIABILITY 21UUNIT9228 5/8/2010 5/8/2011 EACH OCCURRENCE $ 1,000,000 DAMAGE TO RENTED PREMISES (Ea occurrence) $ 300 , 000 I CLAIMS MADE X OCCUR MED EXP (Any one person) $ 10, 000 GENL PERSONAL &ADVINJURY $ 1,000,000 GENERAL AGGREGATE $ 2,000,000 $ 2,000,000 AGGREGATE LIMIT APPUES PER: POLICY JEa LOC PRODUCTS - COMP /OP AGG AUTOMOBILE - -- LIABILITY ANY AUTO ALL OWNED AUTOS SCHEDULED AUTOS HIRED AUTOS NON -OWNED AUTOS COMBINED SINGLE LIMIT (Ea accident) $ BODILY INJURY (Per person) $ BODILY INJURY (Per accident) $ PROPERTY DAMAGE (Per accident) $ GARAGE LIABILITY ANY AUTO AUTO ONLY - EA ACCIDENT $ OTHER THAN EA ACC $ AUTO ONLY: AGG $ EXCESS/ UMBRELLA LIABILITY OCCUR CLAIMS MADE 1 DEDUCTIBLE RETENTION $ EACH OCCURRENCE $ AGGREGATE $ $ $ $ B WORKERS COMPENSATION AND EMPLOYERS' LIABILITY Y / N ANY PROPRIETOR/PARTNER/EXECUTIVE OFFICER/MEMBER EXCLUDED? N (Mandatory lnNH) If yes, describe under SPECIAL PROVISIONS below 830 -25781 12/1/2010 12/1/2011 Y WSTAUS I OTH- E.L EACH ACCIDENT $ 1,000,000 E.L. DISEASE - EA EMPLOYEE $ 1,000,000 E.L DISEASE - POLICY LIMIT $ 1,000,000 OTHER DESCRIPTION OF OPERATIONS / LOCATIONS I VEHICLES / EXCLUSIONS ADDED BY ENDORSEMENT/ SPECIAL PROVISIONS CERTIFICATE HOLDER CANCELLATION (305) 756 -8972 MIAMI SHORES VILLAGE BUILDING DEPARTMENT 10050 NE 2ND AVENUE MIAMI SHORES, FL 33138 SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, THE ISSUING INSURER WILL ENDEAVOR TO MAIL 10 DAYS WRITTEN NOTICE TO THE CERTIFICATE HOLDER NAMED TO THE LEFT, BUT FAILURE TO DO SO SHALL IMPOSE NO OBLIGATION OR LIABILITY OF ANY KIND UPON THE INSURER, ITS AGENTS OR REPRESENTATIVES. AUTHORIZED REPRESENTATIVE Carey Keyes /MS 01IIP 7•••^"" ACORD 25 (2009/01) INS025 (200901) ©1988 -2009 ACORD CORPORATION. All rights reserved. The ACORD name and logo are registered marks of ACORD BOMA 112 GPM at 10' TDH 25' Maximum Head Features: Heavy cast iron construction Oil filled, thermally protected motor Permanently lubricated bearings 2 -vane, corrosion resistant *HYTREL® impeller All stainless steel fasteners and rotor shaft Quick- disconnect 10' standard power cord allows replacement of cord in seconds without breaking seals to motor. (25' length optional) *HYTREL' is a registered trademark of DuPont Polymers LE.:s1M 'f5"W, 12a, lttl rtual 1 i ?a, Automatic 6,8a, iVianu a 6.8,x, Automatic LE5OSERIES TECHNICAL SPECIFICATIONS PUMP The pump(s) shall be model as manufactured by Liberty Pumps, Bergen, NY, or equal. The pump(s) shall have a capacity of GPM at a total dynamic head of feet. Motor size shall be 1/2 horsepower, single phase, 60 hz. and volt operation. MOTOR The pump motor shall be of the submersible type, oil filled, hermetically sealed and shall be thermally protected. The overload element shall automatically reset when motor cools. Motor windings shall be of the class B insulation rating. The rotor shaft shall be made of 416 stainless steel and shall be supported by lower and upper sleeve bearings. The power cord shall be of the quick- disconnect design allowing replacement of the cord without breaking seals to the motor and /or oil chamber. IMPELLER The pump shall have a 2 -vane semi -open impeller capable of passing a 2" spherical solid. SEAL The shaft seal shall be of the carbon /ceramic unitized design, with BUNA N elastomers and stainless housings. EXTERNAL CONSTRUCTION The pump volute, legs and motor housing shall be gray iron castings, class 25 or better. All fasteners shall be of 300 - series stainless steel or brass. All castings shall be epoxy powder coated before assembly. LEVEL CONTROL Automatic units shall be controlled by an adjustable, mercury -free, wide angle float switch. Float cord shall be equipped with a series plug for manual bypass operation. MODELS HP VOLTS PHASE AMPS LE51M LE51A LE52M LE52A 1/2 1/2 1/2 1/2 115 115 230 230 1 1 1 1 12 12 6.8 6.8 DISCHARGE AUTOMATIC IMPELLER 2" FNPT NO 2" FNPT YES 2" FNPT NO 2" FNPT YES 2 -VANE SEMI -OPEN 2 -VANE SEMI -OPEN 2 -VANE SEMI -OPEN 2 -VANE SEMI OPEN 10' cord standard on above models. For 25' cord options, add a " -2" suffix to model number. Example: LE51A -2 for Model LE51A with 25' cord. DIMENSIONAL DATA: Weight: LE51M: 42 LBS. Height: 14" Major Width: 11.5" (manual models) Maximum fluid temperature 140° F. Specifications subject to change without notice 8 PERFORMANCE CURVE 1725 RPM 0 20 40 60 80 100 120 140 U.S. Gallons Per Minute 0 F I I 2.1 4.2 6.3 Liters Per Second 8.4 Liberty Pumps * 7 Apple Tree Avenue • Bergen, New York 14416 • Phone 800- 543 -2550 Fax (585) 494 -1839 www.libertypumps.com Copyright © Liberty Pumps, Inc. 2007 All rights reserved. LLIT 1500 R11/07 with Quick7)ee® Technology The most advanced residential sewage package available Features: Separate access cover QuickTree® float system. Allows easy removal of floats without pulling the pump. * Large 41 gallon capacity Anti-flotation collar * Molded torque-stops Integrally molded handles * Unique integrated cord seal technology Integral rubber cover seals YEN InfiRRIIRTY Shipped with Clear Construction Cover Clear disposable cover protects the system during masonry work and rough-in. QuickTree. re, I- QuickTree® system allows easy access and removal of switches without disturbing pump or plumbing. • Integral rubber seals permanently attached to cover. • Unique cord seal technology. • Inspection /Access cover. • Larger basin - 40% more capacity than standard 18" X 30" basins - decreases switch cycles, improves pump life. • Integrally molded torque stops secure the pump in its proper position. • Integrally molded anti - flotation collar. • Integrally molded handles to ease transportation and installation. • Durable polyethylene construction with radial ribs for added strength. • Completely assembled. Available with any of Liberty's 2" solids - handling sewage pumps. 4 Integral Rubber Seals 1 rrif 21'A" r6 Unique sntegratec cord seal technology and permanent rubber cover gasket:.. MODEL HP VOLTS PHASE DISCHARGE WGT. LBS. P372LE41 4/10 115 1 2" 60 P372LE51 1/2 115 1 2" 64 P372LE52 1/2 208 -230 1 2" 63 P372LE71 3/4 115 1 2" 83 P372LE72 3/4 208 -230 1 2" 83 P372LE102* 1 208 -230 1 2" 86 P372LEH102* 1 208 -230 1 2" 86 For 3" discharge systems change model number from "372" to "373." EXAMPLE: P373LE41 a.specit 4 _t_Serles literature tor �� „rp;�_ ��a�,3,f>pticationson4r. G, , '11 New integrated cord ..__.._- seal technology Separate inspection - -- cover allows access to switches 41 gallon capacity for longer pump cycles Integral handles Quick Tree' removable float system allows easy access to switch - separate from pump. Stainless steel rod. Molded anti - float collar �- P37OXL Series - IAPMO Listed The P370XL systems are specifically designed to pass a 10' stack test and are IAPMO listed. The P370XL- Series has all the same features as the standard P370 except ler a 16 bolt cover. To order, simply add "X" to any standard P370 system. Example: P372XLE41 QuickTree° Kit Pystal ° Pre Simply order a QuickTree Kit and manual 1.?"- pump. , - ainl+ oat . ;US Patent # 7,520,736 arid <7,563,082x` Stainless steel cover bolts Integral rubber permanently attached to covers Into gratfy molded no -hub type inlet, 4" Schedule 8O PVC disciiame pope integr.-: 1 r ^lokted ...o,--,,J..:- stops"` for security Need to install a Liberty pump in an ern; .ty Pro370 basin? ..,No- Problem! QuickTree Kits mako addition of a pump easy! Simply instal! a rri,,. lel LE- Series pump and a matching QuickTree'° Kit. Kits include stainless steel float tree, pre - mounted pump float and additional clamp for an alarm float. hang the QuickTree' fro!), .: ;elder ?.att1 the access cover and yo;,' • sac; MODEL DESCRIPTION QT370- 115 -10 QuickTree" for PRO370,115V,10' cord QT370- 115 -25 QuickTree8 for PROVO, 115V, 25' cord QT370- 230 -10 QuickTree for PR0370, 230V, 10' cord QT370- 230 -25 QuickTree for PRO370, 230V, 25' cord Blow .. A convenient chamber for all your pump's electrical and piping connections - out of sight and below grade. Riser simply slides over the sealed 370 system. Cover is retained by 4 stainless steel bolts and features a twist -lock design with provision for padlock to deter unwanted entry. fica .. . Weight: 28/bs.- (Riser and Cover) Riser Height: 18 -3/4" Total Height with Cover: 20 -1/2" Diameter: 32" MODEL DE;SCRIP . AR18 AC18 ARC18 ARCKIT115 ARCKIT230 IKIT2 -115 IKIT2 -230 Access Riser Access Riser Cover (Environmental Green) Kit, Access Riser with Cover Kit, Access Riser with Cover and 2" installation accessories - 115V Kit, Access Riser with Cover and 2" installation accessories - 230V Installation Kit 2 ", 115V Installation Kit 2 ", 230V liber ypumps Oute. —A acted 115 v ,it Alarm (not shown) Indoor with ,olt Battery Back p L� Pro380 - &€ s systems — Polyethylene Cover Padlock Provision Polyethylene Riser Liberty's installation kits provide ail the components for a professional installation inside the riser. Kit includes: JB- Series wiring box and hardware, check valve with a disconnect union feature, coupling and elbows (PVC piping not included). Kits available in 2" discharge and vent size only. Nov, nave the assurance of earl, ..,,r n.:ig in the event of a high-level condition an alarm option installed from the factory! We - e Won-_ . ryou by mounting the alai-re float ir. tha basin at its prober level -- no need to ever. open the ever! Simply mount the alarm panel in itt. r-::.tz'ted location, supply power and connect the alarm r. =...reads! Offered with three different al: options for indoor or outdoor app!! _ i lions. Alarm Model Add Suffix Ordering Example ALM -2 /A2 P372LE41/A2 ALM -2W /A2W P372LE41/A2W ALM -2 -1 /A21 P372LE41/A21 Alarm is pre-set at prco I _I nba : -in. Alarm rid, -ra .7t t.v tl cn I. Liberty Pumps " 7t '7, Apple Tree Ave /we Bergen, New York 14416 Pt: ine 800- 543 -2550 Fax (585) 494 - ::339 out notice. Ccpyrig t 0 Liberty P ceps, Inc. 2010 Ali rights reset i -d, LLI itiii32/it !,Cqe. -1 pg.ua 1Nto 4q Marl tk) u m adol a F m i Rnj i lvc (Ba,rrcl 0 rl l Versify 11300 N e au& AVE Iwt*Arrti Shore4 f'- ca+" pic(N) 5ewcr ed4V40 flip (N") 3 "P1.0) 3 u plic(/l ) 3t` Pvc 3`' Extsit*'S Seurat xts4t. C1 3441% RtyorA 3a PYC�) ABoue Grbu4 Grecst p 1t -3Comp 514k (QetQa,,+) l_ (+�P Nett ct) Ltme1 To Fee° 3 comp st4k JAN 052011 17 L t \ --1 Miami Shores Village APPROVED BY DATE ZONING DEPT BLDG DEPT ��I� i _7,// A SUBJECT TO COMPLIANCE WITH Al L FFI)( RAI_ STATE AND COUNTY RULES AND H[ (It II AI 'ON /00 e° ish ; C. ?. MO)) ) L hl Erts+tl Tie i O eict<sflue, 4" 5Ewe 6. 4xis iia`i