Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
RF-11-1249
Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Inspection Number: INSP - 162584 Scheduled Inspection Date: August 02, 2011 Inspector: Bruhn, Norman Owner: ROLL, BEVERLY Permit Number: RF -7 -11 -1249 Job Address: 60 NE 111 Street Miami Shores, FL Project: <NONE> Contractor: OCEAN COAST ROOFING Permit Type: Roof Inspection Type: Final Work Classification: Fiat Phone Number Parcel Number 1121360040060 Phone: (754)204 -5007 Building Department Comment RE ROOF FLAT ROOF ONLY' Passed 7 r,, Failed Correction Needed Re- Inspection Fee No Additional Inspections can be scheduled until re- inspection fee is paid. Inspector Comments CREATED AS REINSPECTION FOR INSP- 161925. Flashing at lower roof not complete. Remove excess tar from shingles. Tile and tile mortar must be set properly and be the same color of tile. NB Cc_ August 02, 2011 For Inspections please call: (305)762-4949 Page 17 of 26 4 RE: Permit # r 17 /9 1 as r/€f T j%S (Print name and circle License Type) IYI iami Shores Vitiage Building Department INSPECTION AFFIDAVIT License #: G<_.G /3 Z Z Z Z licensed as a (n FS 468 Building Inspector 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 DATE: 9/Z 5-/ / Contractor Engineer / Architect, On or about 1-77:571// , I did personally inspect the roof deck nailing and (Date & time) Secondary water barrier work at 66C /0 i l %% 6t � ,° ,:5hareS FL 3 ; /('J (Complete Job Site Address) Based upon that examination I have determined the installation was done according to the Hurricane Mitigation Retrofit Manual (Based on 553.844 F.S) r?�-�G ignature State of Florida County of Dade: The undersigned, being the first duly swom, deposes and says that he/she is the contractor for the above property mentioned. Swom to and subscribed before me this day of J tNotary Public, Sate of Florida at Large Oa MARGARET HODGES • Notary Public - State of Florida �', • My Comm. Expires Feb 8, 2014 # DD 953651 O, ,,so st Bonded Through Commission Notary Assn. * • *General, Building, Residential, or Roofing Contractors or any individual certified under 468 F.S. to make such an inspection. Include photographs of each plane of the roof with permit # and address # clearly shown marked on the deck for each Inspection Revised on 5/21/2009 (Ifr ect,Grvij Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 INSPECTION'S PHONE NUMBER: (305) 762.4949 BUILDING PERMIT APPLICATION FBC 20 !'. JUL 1 2311 Permit No. k' ) Master Permit No. Permit Type: BUILDING ROOFING 7 _ OWNER: Name (Fee Simple Titleholder): ,ve X* 1 t✓[) t ( Phone#: 305— 1 3� Address: _ /1% 51 City: $4; Q 01: irrwe.5 State: /— Zip: 3 3 (6,1 Tenant/Lessee Name: Phone #: Email: JOB ADDRESS: 610 &) v 11 / S City: Miami Shores County: Folio/Parcel #: 11-Z(3(o °C! / `' coGn Is the Building Historically Designated: Yes NO Miami Dade zip: 3 31( 1 Flood Zone: ' cLJ (00,1 -- qG 1 ,5t? l CONTRACTOR: Company ©C e.G Ct t WQr1 � Phone #: -5 '20 '0 726'7 Address: iQ Cal Aue-- City: ar /I► 1 State: FC. char -i e S State Certification or Registration #: (r C' %.3 a, 7 as S Certificate of Competency #: / 3 Z l' ZZ. 3 Contact Phone #: Email Address: DESIGNER: Architect/Engineer: Phone #: Qualifier Name: Zip: oeJf Phone#: 945V- 1-11z/-7 Value of Work for this Permit: $ .5( 0O S uare/Linear Footage of Work: 70 fWWarksY Additiot3....:- .IZlAlteration r) ew 7l;��1ail a ,; 1. /Re c bi. ; X4.11, FBesrnptw.V+ n of Rr ti 4. ar i F I 0,:1, . ;, J' Ii017' .• ".( f,1, n�u film +., -;a ❑Demolition ******** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Fees************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** 7f6°° Submittal Fee $ Permit Fee $ Scanning Fee $ Radon Fee $ Notary $ Training/Education Fee $ Double Fee $ Structural Review $ CCF $ CO /CC $ DBPR $ Bond $ Technology Fee $ TOTAL FEE NOW DUE $ r � Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Owner or Ag -'t The foregoing instrument was acknowledged before e, this day of , 20 // , by ,,1/A :U , day of "who is , rsona y known to me or who has produced As identification and who did take an oath. NOTARY PUBLIC: The foregoing instrument was acknowledg before me thi 7 ,20oi,by C s , / known to me or who has produced 1 as identification and who did take an oath. NOTARY PUBLIC: Sign: Print: My Commission Expires: Sign: Print: My Commission ET HODGES 8 2014 oT scion # DD 953851 ()ugh National Notary Assn. ***** ac***** shep*****+ k*+ k*****S: ** aRNs*skve*=k*+k=k°k*tknk**nkDka skskHsskHsiksksi * W :p***akNasbHs*jksNHa***H xsnkHaH kaRa******shnkoknk*sk&+s sggsebsksk=k** **+h*** APPROVED BY Plans Examiner Structural Review (Revised 07 /10 /07)(Revised 06 /10/2009)(Revised 3/15/09) Zoning Clerk Miami Shores Viiiage Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 OWNERS'S AFFIDAVIT OF EXEMPTION ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR EXISTING SITE- BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES PERSUANT TO SECTION 553.844 F.S. To: Miami Shores Village Building Department Date: 10050 NE 2nd Ave Miami Shores, Fl 33138 Re: Owner's Name: 3&VG(1 y IPA ° .o 11 Property Address: i ) 6. i l l 5t i :r'.. . Roofing Permit Number: Dear Building Official: P\U —L-Q_ certify that I am not required to retrofit the roof to wall connections of my building because: e1`he just valuation for the structure for purpose of ad valorem taxation is less than $300,000.00. Please attach proof of ad valorem taxation. ❑ The building was constructed in compliance with the provisions of the Florida Building Code (FBC) or with the provisions of 1994 edition of the South Florida Building Code (1994 SFBC) fAnore)s 3i60 S gnature x B E- v tjLy Ro1 . Print Name State of Florida County of Dade The undersigned, being the first duly swom, deposes and says that he/ he is t Swom to and subscribed before me this f day of Notary Public, Sate of Florida at Large /7/ ' i'j .:.. ..n. ,� MARGARE HO A Notary Public - State of Florida _. +,` • e My. Comm. Expires Feb 8, 2014 y, i,111,1, moo;= Commission # DD 953851 �' O'''''`�: Bonded Through National Notary Assn. e • When the just valuation of the structure for purpose of ad valorem taxation is equal to or more than $300,000.00, and the building was not constructed with FBC nor a 1994 SFBC. Then you must provide a building application from a General Contractor for the Roof to Wall connection Hurricane Mitigation. Revised on 5/2112009 Miami -Dade My Home My Home tams a e. Show Me: Property Information Search By: Select Item ■ Q Text only ij Property Appraiser Tax Estimator EJ Property Appraiser Tax Comparison E+ Portability S.O.H. Calculator Summary Details: Folio No.: 11- 2136 -004 -0060 roperty: 60 NE 111 ST Mailing Address: BEVERLY M ROLL 60 NE 111 ST MIAMI SHORES FL 33161 -7047 Proeerty Information: primary Zone: 1000 SINGLE FAMILY RESIDENCE CLUC: 0001 RESIDENTIAL - INGLE FAMILY Beds/Baths: 2/1 Floors: 1 Living Units: 1 Adj Sq Footage: 1,603 Lot Size: 9,225 SCE FT Year Built 1950 $50,500/ $50,445 36 52 41 COLLEGE Legal HEIGHTS PB 42-8 LOT 6 Desription: BLK 1 LOT SIZE 75.00 X 123 OR- 9659 -1553 OR - 09659.1553 0477 00 Assessment Information: Mr12 2010 2009 EZIMEM $83,801 atgal ;.�r I==1 LLIt1�1-1 YiTh''L'a 1 t$11T2::T4,,�8817 gEMI t x,114 - -,. �?�-i1/ $100 845 ? 1TRE $98 292 Exemption Information: ear. 2010 2009 $25 000 $25,000 Homestead: ® Exemption/ Taxable }nd W Lq'yl'i . "I dip* $500 ACTIVE TOOL_ SELECT Year 2010 2009 Applied Applied Taxing Authority: Exemption/ Taxable Exemption/ Taxable Value: Value: Regional: $50,500/ $50,445 x,'00/ $47,792 County: $50,500/ $50,445 $50,500/ $47,792 City: $50,500/ $50,445 $50,500/ $47,792 School Board: $25,500/ $75,445 $25,500/ $72,792 Sale Information: 'Sale Date: 14/1977 IQCt El Iai fl el El Aerial Photography - 2009 0 113 ft IVIy Home l Property information' Property Taxes 1 My Neighborhood I Property Appraiser Home I Using Our Site 1 Phone Directory I Privacy 1 Disclaimer If you experience technical difficulties with the Property Information application, or wish to send us your comments, questions or suggestions please email us at Webmaster. Web Site O 2002 Miami -Dade County. Ali rights reserved. http:// gisims2. miamidade .gov /myhome /propmap.asp Page 1of2 MIAMI-DADE,)__,I Legend Property Boundary Selected Property edf N Street Highway MIamI -Dade County Water WC_ _,,'E $ 7/8/2011 NOTICE OF COMMENCEMENT A RECORDED COPY MUST BE POSTED ON THE JOB SITE AT :TINS OF FIRST INSPECTION PERMIT NO STATE OF FLORIDA: COUNTY OF MIAMI -DADE: 111111111111111111111111111111111111111111111 TAX FOLIO NO. (1-"/ t 36 — c,oq'6514 THE UNDERSIGNED hereby gives.notice that Improvements will be made to certain real : property, and in accordance with Chapter 713, Florida Statutes, the fofowiing information is provided in this Notice of Commencement. 1 . Legal description of property and street/address: 2. Description of improvement: CFN 2011120416617 OR Bk 27752 Ps 4910; (fps) RECORDED 07/1.2/2011 13:59:34 HARVEY RUVINr CLERK OF COURT MIAMI -DADE COUNTY, FLORIDA LAST PAGE Space above reserved for use of recording off ci 3. Owner(s) name and address: Interest in property: Name and address of fee simple titleholder. 4. Contractor's name, address and phone number: a - rL 37sciv o 4/- 5 757/ ?c 7 5. Surety: (Payment bond required by Owner from contractor, If any) Name, address and phon,e umber. n Amount of bond $ 5 120 6. Lender's name and hddress: 7. Persons Within the -State of Fibrida designated by Owner upon whom notices or other documents may be served as provided by Section 713.13(1)(47„ Florida Statutes; Name, address and phone number s� -- �'L -111. ■Q. A... 8. In addition to himself, Owners designates the following person(s) to receive a copy, of the.Uenor's Notice as provided in Section 713.13(1)(b), Florida-Statutes. Name, address and phone number 9. Expiration date of this Notice of Commencement - (the exphation date is 1 year from the date of recording antes* a different date a specified) WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF CO.MMENCEMENTARE.CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART I, SECTION 7';313. FLORIDA STATUTES; AND CAN RESULT IN SOUR PAYING TWICE FOR IMPROVEMENTS TO. YOUR PROPERTY.. A NOTICE OF COMMENCEMENT MUST` BE # ECORDED AND POSTED: OW THE'JOB SIT-E`BEFORETHE FIRST INSPECTION. IF YOU INTEND to OBTAIN `FINANCING, CONSULT WITH YOUR LENDER OR AN. ATTORNEY- BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. ' Signatures pf Ow , - is),or ® s)' Authorized Officer /Director/Partner/Manager Pre Bred B P By .: t� Prepared By , Print Name . # 1 F V E. 'i.1 - 4 L L Print Name e/ *, STATE OF FLORIDA COUNTY OF MIAMI DADE . The to drib Iii " -Merit ` W dged before ire this BY F�L�1 wally Of "' for eisonally known; br C� produced the following type f efii ` , cation: Signature o`f tart' Public ': Print Name: (S) VERIFICATION PURSUANT TO SECTION 92.525. FLORIDA STATUTES Under penalties of rjuiy 1 declare that "'nitre read ti a for oing shit" that the facts stated In it are true, to the best of my knowledge and belief. Signatures) of Owners) on Owtter(s)'s Authorized Offic er/Direptor/Parttier/Manager who sighed above: OF FLORIC04, COUNTY OF DMA B r day of 29 sot Ow* Owls 4.f. M Miami Shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 7952204 Fax: (305) 756.8972 CONTRACTORS' REGISTRATION FORM ALL CONTRACTORS MUST PROVIDE COPIES OF LICENCES AND INSURANCES EACH TIME A PERMIT IS SUBMITTED OR THE VILLAGE MAY MAINTAIN A FILE WITH YOUR INFORMATION FOR A $30.00 FEE PER YEAR. IF CONTRACTOR IS A FLORIDA STATE CERTIFIED CONTRACTOR: A. COPY OF QUALIFIER'S STATE LIC CARD B. COPY OF LOCAL BUSINESS TAX RECEIPT C. COPY OF LIABILITY INSURANCE (CERTIFICATE HOLDER TO BE MIAMI SHORES VILLAGE BLDG DEPT] D. COPY OF WORKERS COMPENSATION (EITHER CERTIFICATE OR EXCEMPTION) IF CONTRACTOR HAS A MIAMI DADE COUNTY CERTIFICATE OF COMPETENCY: A. COPY OF CERTIFICE OF COMPETENCY OF QUALIFIER B. COPY OF MIAMI DADE COUNTY MUNICIPAL CONTRACTOR'S TAX RECEIPT C. COPY OF LIABILITY INSURACE (CERTIFICATE HOLDER MUST BE MIAMI SHORES VILLAGE BLDG DEPTI D. COPY OF WORKER COMP INSURANCE (EITHER CERTIFICATE OR EXEMPTIONI YOUR INSURANCE COMPANY MUST ISSUE A CERTIFICATE HOLDER AS FOLLOW: MIAMI SHORES VILLAGE BLDG DEPT 10050 NE 2ND AVE MIAMI SHORES, FL 33138 COMPLETE CONTRACTOR'S INFORMATION BUSINESS NAME: OR,ft C C T -� To "i�c IN 9-- BUSINESS ADDRESS: <96 SO t ) ( ( 14 V Q— CITY 176 /4 Gb STATE /!(-- ZIP CODE 3-.307,17 BUSINESS PHONE: ( &') 99/ S 3 3 FAX NUMBER (i, rtd) CELL PHONE (7V-6 5—cr37 QUALIFIER'S NAME: G/ de-e-s QUALIFIER'S LIC NUMBER: ( C C / 3 g. 7 a E -MAIL ADDRESS (IF APPLICABLE): 11 / ",y'Yi G� CI) Created on 3119109 BY MLDV 1 RV 3126109 MLDV al CERTIFICATE OF LIABILITY INSURANCE 7/12/2011 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER, AND THE CERTIFICATE HOLDER. IMPORTANT: if the certificate holder Is an ADDITIONAL INSURED, the policy Iles) must be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER FRANKCRUM INSURANCE AGENCY, INC. 100 S. MISSOURI AVE. CLEARWATER FL 33756 CONTACT NAME MOM P.a. pa awe 1- 600 - 277 -1620 X4800 °p,aAX,�a 727- 787 -0704 SOIL ADasesal INSURER(S) AFFORDING COVERAGE NAICO INSURER a FRANK WINSTON CRUM INSURANCE. INC. 11600 INSURED • FrankCrum 1- 600 - 277-1620 100 5 MISSOURI AVENUE CLEARWATER FL 33756 INSURER B: • INSURER C: INSURERS: $ $ INSURER E DAMAGE TO RENTED PR (Es oawrmosS INSURER Fc I Or1990 oNIRYr1M M111VMM THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDTTTON OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN I8 SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. UNITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAMS. LmR TYPE OF INSURANCE DDL WM SUB POLIOYNUMBER FGLCYEPF (Mtaartur YYI POLICY EXP savnDAYYYY) LIMITS - GENERAL MIRY COMMERCIAL GENERALI.JABL1TY 1SLAe16MADE ®OCCUR • EACH OCCURRENCE $ $ DAMAGE TO RENTED PR (Es oawrmosS MED MCP (Anyc2 Pmsa1I $ . PERSONAL a /WV INJURY $ ,PENWEGATE 1 $ PRODuCTS-COMP/OPAGa GEM AGGREGATE UAW APPUES PM -- IPOUCY • 1-1PRoSET I $. L • AUTOMOBILE ANY NT AUTO UTB AU. OWNED ALIT08 AUTOS SCHEDULED NON -OWNED ` Z Mt $ BODILY INJURY (Per persdn) $ • BODILY INJURY (Pe1'aa 6 .. _ WOBPERTYDAMAGE (Par $ —� _._,,N.17118 $ — �NUiED . .• UMBRELLA LAB EXCESS LAB QCCUR• CLAIMS-MADE 1AOHOCICE .. $ AGGRESATB $ DEED I RETENTION A WORKERS EMPLOYERS* PRY PROPRIETOROARTIVINEXECUTIVE OFFICERMEMBER Udandet Yr s,dm�ennder DESCRIPTION COMPENSATION AND L AMM EXCUIDEDT _ ryInNH) OP OPERATIONS below NIA WC201100000 1H/2011 1/1/2012 ViC STATU OTX- X (TORY En E/ EL OCR ACCIDENT 51,000,000 E,L,DBEASE•F1IEMPLOYEE $1.000.000 51.000,000 EJ..OISEASE- PCLIC'rLIMIT • • • DESCRIPTION EFFECTIVE CLIENT OF OPERATIONS I LOCATION8I VEHICLES (AIM&ACORD 101, Addiimnal Remarks Schedule, Dmore space le nsluked) 061021201 1; COVERAGE IS FOR 100% OF THE EMPLOYEES OF FRANKCRUM LEASED TO OCEAN COAST ROOFING, INC. (CLIENT) FOR WHOM THE IS REPORTING HOURS TO FRANKCRUM. COVERAGE IS NOT EXTENDED TO STATUTORY EMPLOYEES. • wise uTIeN CERTIFICATE HOLD CITY OF MIAMI SHORES 10050 NE 2ND AVENUE MIAMI SHORES, FL 33138 SHOULD ANY OF THE ABOVE DESCRIBED POUCIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POUCY PROVISIONS. AU DRMEO REPRESENTATIVE ACORD 20 (2010105) The ACORD name and logo are registered marks otACORD tS 18s -2010 ACORD CORPORATION. AO rights reserved. g CERTIFICATE OF LIABILITY INSURANCE DATE 07 /12DIYYYY) 07/12/11 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER, AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED, the policy(ies) must be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder In lieu of such endorsement(s). PRODUCER Marlins Insurance 850 S.W. 40 Ave. Plantation, FL 33317 Phone (954)587 -7850 Fax (954)587 -7778 CONTACT Angola PHONE 95 gg�9994 FAX (954)989-3995 Ext): ( ) (A/C, Not (AI Lo. ADDRESS: marllnsii@aol.com INSURER(S) AFFORDING COVERAGE NAIC # INSURER A : Century Insurance Group N INSURED Ocean Coast Roofing Inc. 2050 N 61 Ave Hollywood, FL 33024 (9554) 966 -5854 INSURER B : 03/28/2011 INSURER C : EACH OCCURRENCE INSURER D : DAMAGE TO RENTED PREMISES (Ea occurrence) INSURER E : V COMMERCIAL GENERAL LIABILITY INSURER F : $ 5,000.00 COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POUCY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POUCIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. ILTR TYPE OF INSURANCE NSRLSWVD POLICY NUMBER (MMILDDYIYYYY) (MMIDDIYYYY) LIMITS A GENERAL LIABILITY N CCP698878 03/28/2011 03/28/2012 EACH OCCURRENCE $ '1,000,000.00 DAMAGE TO RENTED PREMISES (Ea occurrence) $ 10000000 V COMMERCIAL GENERAL LIABILITY MED EXP (Any one person $ 5,000.00 ❑ ❑ CLAIMS -MADE V OCCUR ❑ PERSONAL & ADV INJURY $ 1,000,000.00 ❑ GENERAL AGGREGATE $ 2,000,000.00 GEN'L AGGREGATE UMIT APPLIES PER: PRODUCTS - COMP /OP AGG $ 2,000,000.00 V POLICY ❑ JECT ❑ LOC $ AUTOMOBILE LIABILITY ❑ ANY AUTO ALL OWNED SCHEDULED ❑ AUTOS ❑ AUTOS ❑ HIRED AUTOS ❑ AUTO-0OWNED ❑ ❑ COMBINED SINGLE UMIT (Ea accident) $ BODILY INJURY (Per person) $ BODILY INJURY (Per accident) $ (Per acciden DAMAGE $ $ ❑ UMBRELLA LIAB ❑ OCCUR ❑ EXCESS LIAB ❑ CLAIMS -MADE EACH OCCURRENCE $ AGGREGATE $ ❑ DED ❑ RETENTION $ $ WORKERS COMPENSATION AND EMPLOYERS' LIABILITY Y 1 N ANY PROPRIETOR/PARTNER/EXECUTIVE N / A ❑ ORY LA ❑ ER M S EL. EACH ACCIDENT $ OFFICER/MEMBER EXCLUDED? (Mandatory In NH) E.L. DISEASE - EA EMPLOYE $ If yes describe under DESCRIPTION OF OPERATIONS below E.L. DISEASE - POUCY UMIT $ DESCRIPTION OF OPERATIONS / LOCATIONS / VEHICLES (Attach ACORD 101, Additional Remarks Schedule, If more space Is required) ROOFING ICATE HOLDER CANCELLATIO I CITY OF MIAMI SHORES 10050 NE 2ND AVE MIAMI SHORES, FL 33138 SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE ACORD 25 (2010105) QF ©1988- 20'tOTACOo CORPORATION. All rights resery ed. The ACORD name and logo are registered marks of ACORD IN 115 Business Name: Owner Name: Business Location: Business Phone: Rooms S. Andrews Ave., Rm. A -100, Ft. Lauderdale, FL 33301 -1895 — 954 - 831 -4000 VALID OCTOBER 1, 2010 THROUGH SEPTEMBER 30, 2011 DBA: Receipt #:377-232064 OCEAN COAST ROOFING INC Business T yp e :OFFICE /SALES (ROOFING OFFICE) COLLEEN GEDDIS Business Opened:03 /25/2010 2050 W 61 AVE State /County /CertlReg: HOLLYWOOD Exemption Code:NONEXEMPT 754-204-5007 Seats Employees Machines Professionals /BUSINESS /AI For Vending Business Only Number of Machines: Vending Type: Tax Amount Transfer Fee NSF Fee Penalty Prior Years ' Collection Cost Total Paid 45.00 0.00 0.00 0.00 0.00 0.00 45.00 THIS RECEIPT MUST BE POSTED CONSPICUOUSLY IN YOUR PLACE OF BUSINESS THIS BECOMES A TAX RECEIPT This tax is levied for the privilege of doing business within Broward County and is - non- regulatory in nature. You must meet all County and /or Municipality planning WHEN VALIDATED and zoning requirements. This Business Tax Receipt must be transferred when the business is sold, business name has changed or you have moved the business location. This Geceipt does not indicate that the business is legal or that it is in compliance with.State or local laws and regulations. Mailing Address: COLLEEN GEDDIS Receipt #04A -09- 00018801 2050 W 61 AVE Paid 09/30/2010 45.00 HOLLYWOOD, FL 33024 • 2010 - 2011 ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Florida Building Code Edition 2 High - Velocity Hurricane Zone Uniform Permit Applic 1)— et-- Miami Shores Village APPROVED BY DATE ZONING DEPT "YLDG DEPT 22k7 FEDERAL km FUIIII. SUBJECT TO COMPLIANCE WITH ALL STATE AND COUNTY RULES AND REGULATIONS Master Permit No. Process No. Contractor's Nameeaer4a �� . 'S\° 'b4 AC_ IAA i Job Address (OV( ((I t 5'k— M10..wi1. �C � $ r% 1 I ow Slope Asphaltic Shingles ❑ Mechanically Fastened Tile ❑ Metal Panel /Shingles ❑ Prescriptive BUR -RAS 150 ROOF TYPE ❑ New Roof ®'Reroofing ❑ Recovering Low Slope Roof Area (SF) ROOF SYSTEM INFORMATION ❑ Mortar /Adhesive Set Tile ❑ Wood Shingles /Shakes ❑ Repair ❑ Maintenance Steep Sloped Roof Area (SF) Total (SF) Section B (Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. A FLORIDA BUILDING BUILDING 7 ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Florida Building Code Edition 2007 High - Velocity Hurricane Zone Uniform Permit Application Form. %® Surfacing: kilo Fastener Spacing for Anchor/Base Sheet Attachment: Field: O " oc @ Lap, # Rows 3 @ oc Z Perimeter di' " oc @Lap, # Rows '� @ " oc Corner: O" oc @ Lap, # Rows@ 8 " oc Number of Fasteners Per Insulation Board: Section C (Low Slope Application) Fill In specific roof assembly components and identify manufacturer (If a component is not used, identify as "NA ") System Manufacturer. C�,��Q, C 1p % 'V Cie OCt Product Approval No.: Design Wind Pressures, From � RAS 128 or Calculations: Pmax2: -1'T Pmax3: --im. I Max. Design Pressure, f lt the spsclflc Product Approval system: 9 r4S r Deck: l / 1pbbri YP e J� Gauge/Thickness: 5 /�j Slope: Anchor/Base Sheet & No. of Ply(s): l v 4-45- 1 oras�e §bee ener/Bonding Material: Insulation Base Layer. Base Insulation Size and Thickness: Base Insulation FastenerBonding Mats Top Insulation Layer: Top Insulation Size and Thickness: Aid/ Top Insulation Fastener/Bonding Material: ,/9 Base Sheet(s) & No. of Ply(s): Besot SrAsiten ndigg N,JBteril: Ply Sheet(s) & No. of Ply(s): /,4-64 Ply Sheet Fastener/Bo i Top Ply: 4 Mteri;I: 7 115, ,rif Top Ply FastenerB • M -j. rlal: FLORIDA BUILDING CODE — BUILDING Field Perimeter Corner Illustrate Components Noted and Details as Applicable: Woodblocking, Gutter, Edge Termination, Stripping, Flashing, Continuous Cleat, Cant Strip, Base Flashing, Counter - Flashing, Coping, Etc. Indicate: Mean Roof Height, Parapet Height, Height of Base Flashing, Component Material, Material Thickness, Fastener Type, Fastener Spacing or Submit FT 1 Parapet Height Mean Roof Height SECTION R4402.13 HIGH VELOCITY HURRICANE ZONES — REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS R4402.13.1 Scope. As it pertains to the section, it is the responsibility of roofing contractor to provide the owner with the required roofing permit, and to explain to the owner the content of the section. The provisions of Section R4402 govem the minimum requirements and standards of the industry for roofing system installations. Additionally, the following items should be addressed as part of the agreement between the owner ant the contractor. The owner's initial in the designated space indicates that the item has been explained. 1. R i. Aesthetics-Workmanship: the workmanship provisions of Section R4402 are for the purpose of providing that the roof system meets the wind resistance and water instruction performance standards. Aesthetics (appearance) are not a consideration with respect to workmanship provisions. Aesthetic issues such as color or architectural appearance, that are not part of a zoning code, should be addressed as part of the agreement between the owner and the contractor. 2. B R Renailing wood decks: When replacing roofing, the existing wood roof deck may have to be renailed in accordance with the current provisions of Section R4403. (The roof deck is usually concealed prior to removing the existing roof system). 3. -8 Ti 1\ Common roofs: Common roofs are those which have no visible delineation between neighboring units (i.e., townhouses, condominiums, etc.) In buildings with common roofs, the roofing contractor and/or owner should notify the occupants of adjacent units of roofing to be performed. 4. 13 R Exposed Ceiling: Exposed, open beam ceilings are where the underside of the roof decking can be viewed from below. The owner may wish to maintain the architectural appearance; therefore, roofing nail penetration of the underside of the decking may not be acceptable. This provides the option of maintaining the appearance. 5. J Ponding water: The current roof system and /or deck of the building may not drain well and may cause water to pond (accumulate) in low -lying areas of the roof. Pounding can be an indication of structural distress and may require the review of a professional structural engineer. Pounding may shorten the life expectancy and performance of the new roofing system. Pounding conditions may not be evident until the original roofing system is removed. Pounding conditions should be corrected. 6. 13 R Overflow scuppers (wall outlets): It is required that rainwater flows off so that the roof is not overloaded from a buildup of water. Perimeter /edge wall or other roof extension may block this discharge if overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in accordance with the requirements of Sections R4402, R4403 and R4413. 7. Ventilation: Most roof structures should have some ability to vent natural airflow through the interior of a structure assembly (the building itself). The existing amount of attic ventilation shall not be reduced. It may be beneficial to consider additional venting which can result in extending the service life of the roof. \_11177_a /'»' wner /A ents Signatur Date Contra ' r Signature ate 9 9 9 Revised on 7/9/2009 LD MIAMIOADE BUILDING CODE COMPLIANCE OFFICE (BCCO) PRODUCT CONTROL DIVISION NOTICE OF ACCEPTANCE (NOA) CertainTeed Corporation (PA) 1400 Union Meeting Road, P.O. Box 1100 Blue Bell, PA 19422 MIAMI-DADE COUNTY, FLORIDA METRO -DADE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 MIAMI, FLORIDA 33130 -1563 (305) 375 -2901 FAX (305) 375 -2908 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by the BCCO and accepted by the Building Code and Product Review Committee to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This. NOA shall not be valid after the expiration date stated below. The BCCO (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BCCO reserves the right to revoke this acceptance, if it is determined by BCCO that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and . has been designed to comply with the Florida Building Code and the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: CertainTeed Modified Bitumen Roofing Systems Over Wood Decks LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement "Miami Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA No. 03- 0827.02 and consists of pages 1 through 39. The submitted documentation was reviewed by Jorge L. Acebo. NOA No.: 08- 0227.09 Expiration Date: 06/19/13 Approval Date: 05/15/08 Page 1 of 39 ROOFING ASSEMBLY APPROVAL Category: Sub - Category: Deck Type: Maximum Design Pressure Roofing APP /SBS Modified Bitumen Wood -60 psf TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Product All Weather/Empire Base Sheet Flex I- G1asTm Base Sheet Flex- I- G1asTm FR Base Sheet Flintglas® Ply Sheet Type IV or VI Flintlastic STA STA Plus 5.0 Flintlastic GTA, GTA - FR or Flintlastic Diamond GTA Flintlastic GTS Flintlastic GMS, Premium GMS Flintlastic FR P, Premium FR -P Flintlastic FR Cap Flexiglas Premium Cap 960 Gaa7uffi..1') 4"•1•1'1.1 !O 1APPROVED Dimensions 36" x 72', Roll weight 86 lbs. (2 squares) 36" x 108', Roll weight 90 lbs. (3 squares) 39 34" x 50', Roll weight: 90 lbs. (1.5 squares) 36" x 180', Roll weight: 40/55 lbs. (5 squares) 39 3/8' x 33', Roll weight: 90 lbs. (1 square) 39 3 /8" x 33' 3 ", Roll weight 105 lbs. (1 square) 39 34" x 24'9 ", Roll weight: 92 lbs. (34 square) 39 3 /s' x 34' 2 ", Roll weight 100/105 lbs. (1 square) 3931$'x34'2 ",Roll weight: 105 lbs. (1 square) 39 318" x 34' 2 ", Roll weight: 90 lbs. (1 square) 36" x 38" (1 square) Test Product Sneciflcation Description ASTM D 2626 UL Asphalt coated organic base sheet. Type 15 UL Type G2 ASTM D 4601, type II UL Type G2 ASTM D 4601, type II ASTM D 2178 Type W or VI UL Type G1 ASTM D 6222, Grade S, Type II ASTM D 6222, Grade G, type II ASTM D 6164, Grade G, Type II ASTM D 6164, Grade 0, Type II ASTM D 6164, Grade G, Type I ASTM D 6163, Grade G, Type I ASTM D 6163, Grade 0, Type I Modified Bitumen coated fiberglass base sheet. Modified Bitumen coated fiberglass base sheet. Fiberglass, asphalt impregnated ply sheet. Smooth surfaced APP Modified Bitumen membrane with non -woven polyester mat reinforcement for torch application. Granule surfaced APP Modified Bitumen membrane with non -woven polyester mat reinforcement for toch application. Granule surfaced SBS Modified Bitumen membrane with non -woven polyestermat reinforcement for torch application. Granule surfaced SBS Modified Bitumen membrane with non -woven polyester mat reinforcement for mop application. Fire resistant, granule surfaced SBS Modified Bitumen Membrane with non- woven polyester mat reinforcement for mop application. Fire resistant, granule surfaced SBS Modified Bitumen membrane with fiberglass mat reinforcement for mop applications. Granule surfaced SBS Modified Bitumen membrane with fiberglass, mat reinforcement for mop application. NOA No.: 08- 0227.09 Expiration Date: 06/19/13 Approval Date: 05/15/08 Page 2 of 39 Product Ultra Poly SMS G1asBaseTM Base Sheet PoIySMS Base Sheet Yosemite® Mineral Surfaced Cap Sheet Black Diamond Base Sheet Flintglas® Mineral Surfaced Cap Sheet Dimensions 36" x 64'4" (2 squares) 36" x 108', Roll weight 69 lbs. (3 squares) 39 3/8" x 64' 4 ", Roll weight: 90 lbs. (2 squares) 36" x 36, Roll weight 90 lbs. (1 square) 36" x 75', Roll weight 75 lbs. (2.25 squares) 36 "X36 ; Roll Weight: 78 lbs. (1 square) APPROVED INSULATIONS: Product Name FlintBoard ISO PYROX ACFoam 11 ISO 95+ High Density Wood Fiberboard Perlite Insulation Dens Deck ENRGY-1; ENRGY 2, ENRGY -3, Plus, UltraGard Gold, PSI -25 FiberGlass Roof Insulation Fesco Board ISORoc Paroc Cap Board Multi-Max, FA Test Specification ASTM D 6164 Grade S, Type I ASTM D 4601 UL Type 02 ASTM D 5147 ASTM D 249 UL Type 30 TAS 103 ASTM D 1970 ASTM D 3909 Product Description Smooth surfaced SBS Modified Bitumen Membrane with non -woven polyester mat reinforcement for mop application. Asphalt coated, fiberglass base sheet. Modified Bitumen coated polyester base sheet. Mineral Surfaced organic cap and buffer sheet. Slag surfaced SBS Modified Bitumen sheet with fiberglass reinforcement for peel and stick application. Asphalt impregnated and coated inorganic glass fiber surfaced with mineral granules used as the top ply in conventional built - up roof membranes. TABLE 2 Product Description Polyisocyanurate foam insulation Polyisocyanurate foam insulation Polyisocyanurate foam insulation Polyisocyanurate foam insulation Wood fiber insulation board Perlite insulation board Water resistant gypsum board Polyisocyanurate foam insulation Glass fiber /Mineral fiber insulation Expanded mineral fiber insulation Polyisocyanurate foam / rockwool composite insulation Rockwool insulation Polyisocyanurate foam insulation Manufacturer (With Current NOA) CertainTeed Apache Products Co. Atlas Energy Products Firestone Building Products, Inc. generic generic G -P Gypsum Corp. Johns Manville Johns Manville Johns Manville Johns Manville Partek, Inc. RMax, Inc. NOA No.: 08-022'7.09 Expiration Date: 06 /19/13 Approval Date: 05/15/08 Page 3 of 39 APPROVED FASTENERS: Fastener Product Number Name 1. #12 & #14 Dekfast Fastener 2. Dekfast Hex Plate TABLE 3 Product Description Insulation fastener Galvalume AZ50 steel plate 3. Olympic Fastener #12 Insulation fastener & #14 4. Olympic Standard 5. Insul -Fixx Fastener 6. Insul -Fixx S Plate 7. Tru-Fast Fasteners 8. Tru -Fast MP -3 9. Tru-Fast Plates 10. Tru-Fast Plates EVIDENCE SUBMITTED: Test Agency Applied Research Laboratories Factory Mutual Research Corporation Factory Mutual Research Corporation 7nderwriters Laboratories, Inc. United States Testing Company, Exterior Research & Design, LLC Exterior Research & Design, LLC Exterior Research & Design, LLC 3" round galvalume AZ50 steel plate Insulation fastener for steel and wood decks Galvalume AZ50 steel plate Insulation fastener for wood and steel decks Galvalume AZ50 steel plate Galvalume AZ55 steel plate Polyethylene plastic plate Name Physical Properties Current Insulation Fastening Requirements PA 114 (FMRC 4470) Fire Classification Compliance ASTM D 5147 TAS 114 (J) TAS 114 TAS 117 Manufacturer Dimensions (With Current NOA) Construction Fasteners, Inc. 2 7 /8" x 3 Y4" Construction Fasteners, Inc. 3" round 3 " round 3" round 3" round 3" round Olympic Manufacturing Group, Inc. Olympic Manufacturing Group, Inc. SFS Stadler, Inc. SFS Stadler, Inc. The Tru -Fast Corp. The Tru-Fast Corp. The Tru-Fast Corp. The Tru-Fast Corp. 28013 06/02/87 FMRC 1994 01/01/95 #3Y8A1.AM 03/23/96 R11656 07/13/87 97457 -4 06/03/88 #3507.08.99 -1 04/18/01 • #3514.02LAB 11/11/02 #3515.07.03 07/22/03 NOA No.: 08- 0227.09 Expiration Date: 06/19/13 Approval Date: 05/15/08 Page 4 of 39 APPROVED ASSEMBLIES: Membrane Type: APP MODIFIED Deck Type 11: Wood, Insulated Deck Description: 19/32" or greater plywood or wood plank System Type A(1): Anchor sheet mechanically fastened; all layers of insulation adhered with approved asphalt. All General and System Limitations apply. One or more layers of any of the following insulations. Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 Pyrox Minimum 13" thick N/A N/A ACFoam -II, UltraGard Gold, ENRGY -1, ENRGY -2, PSI -25, FlintBoard ISO Minimum 1.5" thick N/A N/A Fiberglas Minimum 15/16. thick N/A N/A Perlite Minimum 3/a" thick N/A N/A High Density Wood Fiberboard Minimum W' thick N/A N/A Dens Deck Minimum V4" thick N/A N/A Note: All insulation shall be adhered to the anchor sheet in full mopping of approved hot asphalt within the EVT range and at a rate of 20-40 lbs/100 ft2. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulation listed as base layer only shall be used only as base layers with a second layer of approved top layer insulation installed as the final membrane substrate. Composite insulation panels may be used as a top layer placed with the polyisocyanurate side facing down. Anchor Sheet: One ply of Glas Base, Flex -I Glas Base, Flex -I Glas FR Base or Poly SMS base mechanically attached as detailed below. Fastening. Anchor sheet shall be lapped 4" and fastened with approved roofing nails and tin caps 9 "o.c. in the lap and two rows staggered in the center of the sheet 12 "o.c. Base Sheet Ply Sheet: One ply of products listed under 'Anchor Sheet' above adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. (Optional) One or more plies of Flintglas Ply Sheet (Type IV) or Flintglas Premium Ply Sheet (Type VI) adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. NOA No.: 08-0227.09 Expiration Date: 06119/13 Approval Date: 05115/08 Page 5 of 39 Membrane: Plintlastic STA, Flintlastic STA Plus 5.0, Flintlastic Diamond GTA, Flintlastic GTA or GTA-FR torch adhered to base/ply sheet. Surfacing. (Optional) Install one of the following: 1. 400-1b./sq. gravel or 300- lb./sq. slag in a flood coat of approved mopping asphalt at an application rate of 60lbsq. 2. Karnak 97, FlintCoat A -150, APOC 212 Fibrated Aluminum, Henry 520 Alunvnum or Grundy AL MB at an application rate of 1 V2 gal. Isq. Maximum Design Pressure: -45 psf (See General Limitation #9) NOA No.: 08-0227.09 Expiration Date: 06/19/13 Approval Date: 05/15/08 Page 6 of 39 Membrane Type: SBS MODIFIED Deck Type 11: Wood, Insulated Deck Description: 19/32" or greater plywood or wood plank System Type A(2): Anchor sheet mechanically fastened; all layers of insulation adhered with approved asphalt. All General and System Limitations apply. One or more layers of any of the following insulations. Insulation Layer Insulation Fasteners Fastener (Table 3) Density /ft2 Pyrox Minimum 1.3" thick N/A N/A ACFoam -II, UltraGard Gold, E'NRG'Y -1, E'NRG'Y -2, PSI -25, FlintBoard ISO Minimum 1.5" thick N/A N/A Fiberglas Minimum 1546" thick N/A N/A Perlite Minimum Ve" thick N/A N/A N/A N/A High Density Wood Fiberboard Minimum W' thick Dens -Deck • Minimum Y*" thick N/A N/A Note: All insulation shall be adhered to the anchor sheet in full mopping of approved hot asphalt within the EVT range and at a rate of 2d- 401bsF100 ft2. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulation listed as base layer only shall be used only as base layers with a second layer of approved top layer insulation installed as the final membrane substrate. Composite insulation panels may be used as a top layer placed with the polyisoeyanurate side fading down. Anchor Sheet: One ply of Glas Base, Flex -I Glas Base, Flex -I Gies FR Base or Poly SMS base mechanically attached as detailed below. Fastening- Anchor sheet shall be lapped 4" and fastened with approved roofing nails and tin caps 9 "o.c. in the lap and two rows staggered in the center of the sheet 12 "o.c. Base Sheet One ply of products listed under 'Anchor Sheet' above adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs.sq. Ply Sheet One more plies of Ultra Poly SMS, Flintglas Ply Sheet (Type IV) or Flintglas Premium Ply Sheet (Type VI) adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs sq. NOA No.: 08- 0227.09 Expiration Date: 06/19/13 Approval Date: 05/15/08 Page 7 of 39 Membrane: One ply of Flintlastic GMS, Flintlastic Premium GMS, Flintlastic FR P, Flintlastic Premium FR P, Flintlastic FR Cap sheet, Plexiglas Premium Cap 960, Ultra Poly SMS or Flintglas Mineral Surfaced Cap Sheet adhered to base/ply sheet with approved mopping asphalt applied within the EVT range and at a rate of 20 to 40 lbsJsq. or Flintlastic GTS. torch adhered to base/ply sheet. Surfacing: (Optional) Install one of the following: 1. 400- 1b. /sq. gravel or 300-lb./sq. slag in a flood coat of approved mopping asphalt at an application rate of 601bfsq. 2. Karnak 97, FlintCoat A -150, APOC 212 Fibrated Aluminum, Henry 520 Aluminum or Grundy AL MB at an application rate of 1 Vi gal. /sq. Maximum Design Pressure: -45 psf (See General Limitation #9) NOA No.: 0 8-0227.09 Expiration Date: 06/19/13 Approval Date: 05 /15 /08 Page 8 of 39 Membrane Type: APP MODIFIED Deck Type 1I: Wood, Insulated Deck Description: 19/32" or greater plywood or wood plank System Type A(3): Anchor sheet mechanically fastened; all layers of insulation adhered with approved asphalt. All General and System Limitations apply. One or more layers of any of the following insulations. Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 ACFoam -H, Multi-Max FA, ENRGY -3, FlintBoard ISO NFuaimujn 1.5" thick N/A N/A Note: All insulation shall be adhered to the anchor sheet in fall mopping of approved hot asphalt within the EVT range and at a rate of 20-40 lhs/100 ft2. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulation listed as base layer only shall be used only as base layers with a second layer of approved top layer insulation installed as the final membrane substrate. Composite insulation panels may be used as a top layer placed with the polyisocyanurate side facing down. Anchor Sheet One ply of Glas Base or Flintglas Premium Ply Sheet (Type VI) mechanically attached as detailed below. Fastening: Anchor sheet shall be lapped 4" and fastened with 11 ga. annular ring shank nails and approved tin caps 8 "o.c. in the lap and three rows staggered in the center of the sheet 8 "o.c. Base Sheet: One ply of Black Diamond Base Sheet self - adhered. Ply Sheet: (Optional ) One ply of Ultra Poly SMS, Glas Base, Flex -I Glas Base, Flex -I Glas FR Base or Poly SMS or one or more plies of Flintglas Ply Sheet (Type IV) or Flintglas Premium Ply Sheet (Type VI) adhered in a frill mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs.sq. Membrane: Flintlastic STA, Flintlastic STA Plus 5.0, Flintlastic Diamond GTA, Flintlastic GTA or GTA-FR torch adhered to base/ply sheet. Surfacing: (Optional) Install one of the following: 1. 400- 1b./sq. gravel or 300-1b./sq. slag in a flood coat of approved mopping asphalt at an application rate of 60 Ibisq. 2. Karnak 97, FlintCoat A -150, APOC 212 Fibrated Aluminum, Henry 520 Aluminum or Grundy AL MB at an application rate of 11 gal. /sq. Maximum Design Pressure: -52.5 psf (See General Limitation #7) NOA No.: 08-0221.09 Expiration Date: 06/19/13 Approval Date: 05/15/08 Page 9 of 39 Membrane Type: SBS MODIFIED Deck Type 11: Wood, Insulated, New Construction Deck Description: I9/32" or greater plywood or wood plank System Type A(4): Anchor sheet mechanically fastened; all layers of insulation adhered with approved asphalt. All General and System Limitations apply. One or more layers of any of the following insulations. Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 ACFoam -11, UltraGard Gold, ENRGY-2, ENRGY -3, PSI.25, FlintBoard ISO Minimum 1.5" thick N/A N/A Fiberglas Minimum 15 /16" thick N/A N/A Perlite Minimum Y(" thick N/A N/A High Density Wood Fiberboard Minimum W' thick N/A N/A Dens -Deck Minimum 4(1' thick N/A N/A Note: All insulation shall be adhered to the anchor sheet in full mopping of approved hot asphalt within the EVT range and at a rate of 20-40 lbs/100 fe. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulation listed as base layer only shall be used only as base layers with a second layer of approved top layer insulation installed as the final membrane substrate. Composite insulation panels may be used as a top layer placed with the polyisocyanurate side facing down. Anchor Sheet One ply of Glas Base or Flintglas Premium Ply Sheet (Type VI) mechanically attached as detailed below. Fastening: Anchor sheet shall be lapped 4" and fastened with 11 ga. annular ring shank nails and approved tin caps 8 "o.c, in the lap and three rows staggered in the center of the sheet 8 "o.c. Base Sheet: One ply of Ultra Poly SMS, Glas Base, Flex -I Glas Base, Flex -I Glas FR Base or Poly SMS base adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 2040 lbs./sq. Ply Sheet (Optional) One or more plies of Flintglas Ply Sheet (Type IV) or Flintglas Premium Ply Sheet (Type VI) adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbsdsq. NOA No.: 08-0227.09 Expiration Date: 06/19/13 Approval Date: 05/15/08 Page 10 of 39 Membrane: Surfacing: One ply of Flintlastic GMS, Flintlastic Premium GMS, Flintlastic FR P; Flintlastic Premium FR -P, Flintlastic FR Cap sheet, Plexiglas Premium Cap 960, Ultra Poly SMS or Flintglas Mineral Surfaced Cap Sheet adhered to base/ply sheet with approved mopping asphalt applied within the EVT range and at a rate of 20 to 40 lbs. /sq. or Flintlastic GTS torch adhered to base/ply sheet. (Optional) Install one of the following: 1. 400- 1bisq. gravel or 300-1b./sq. slag in a flood coat of approved mopping asphalt at an application rate of 60lbsq. 2. Karnak 97, FlintCoat A -150, APOC 212 Fibrated Aluminum, Henry 520 Aluminum or Grundy AL MB at an application rate of 1 i/i gal. /sq. Maximum Design Pressure: -52.5 psf (See General Limitation #7) APPROVED NOA No.: 08- 0227.09 Expiration Date: 06/19/13 Approval Date: 05/15/08 Page 11 of 39 Membrane Type: APP MODIFIED Deek Type 2i: Wood, Insulated, New construction Deck Description: Minimum 19/32" thick plywood attached using approved nails spaced 4" o.c. at wood joists spaced maximum 24" o. c. System Type A(5): Anchor sheet mechanically fastened; all layers of insulation adhered with approved asphalt. All General and System Limitations apply. One or more layers of any of the following insulations. Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 ACFoam -II, Multi-Max FA, ENRGY -3, FlintBoard ISO Minimum 1.5" thick N/A N/A Note: All insulation shall be adhered to the anchor sheet in full mopping of approved hot asphalt within the EVT range and at a rate of 20 -40 tbsI100 ft2. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulation listed as base layer only shall be used only as base layers with a second layer of approved top layer insulation installed as the final membrane substrate. Composite insulation panels may be used as a top layer placed with the polyisocyanurate side facing down. Anchor Sheet: One ply of GlasBase or Flintglas Premium Ply Sheet (Type VI) mechanically attached as detailed below. Fastening: Anchor sheet shall be lapped 4" and fastened with 11 ga. annular ring shank nails and approved tin caps 8 "o.c. in the lap and three rows staggered in the center of the sheet 8" o.c. Base: One ply of Black Diamond Base Sheet self- adhered. Ply Sheet Membrane: Surfacing: (Optional ) One ply of Ultra Poly SMS, Glas Base, Flex -I Glas Base, Flex -I Glas FR Base or Poly SMS base or one or more plies of Flintglas Ply Sheet (Type IV) or Flintglas Premium Ply Sheet (Type VI) adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs. /sq. Flintlastic STA, Flintlastic STA Plus 5.0, Flintlastic Diamond GTA, Flintlastic GTA or GTA -FR torch adhered to base or ply sheet. (Optional) Install one of the following: 1. 400- lb /sq. gravel or 300- lb./sq. slag in a flood coat of approved mopping asphalt at an application rate of 60 lb./sq. 2. Karnak 97, FlintCoat A -150, APOC 212 Fibrated Aluminum, Henry 520 Aluminum or Grundy AL MB at an application rate of 1 !h gal. /sq. Maximum Design Pressure: - 60psf. (See General Limitation #7) NOA No.: 08- 0227.09 Expiration Date: 06/19/13 Approval Date: 05/15/08 Page 12 of 39 Membrane Type: SBS MODIFIED Deck Type 1L Wood, Insulated, New Construction Deck Description: Minimum 19/32 " thick plywood attached using approved nails spaced 4" o.c. at wood joists spaced maximum 24" o. c. System Type A(6): Anchor sheet mechanically fastened; all layer of insulation adhered with approved asphalt All General and System Limitations apply. One or more layers of any of the following insulations. Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 ACFoam -II, UltraGard Gold, ENRGY -2, ENRGY -3, PSI -25, FlintBoard ISO M nimum 1.5" thick N/A N/A Fiberglas Minimum 1s /16" thick N/A N/A Perlite Minimum Va" thick N/A N/A High Density Wood Fiberboard Minimum Y2" thick N/A N/A Dens Deck Minimum W' thick N/A N/A Note: All insulation shall be adhered to the anchor sheet in full mopping of approved hot asphalt within the EVT range and at a rate of 20.40 Ibs/100 ft2. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulation listed as base layer only shall be used only as base layers with a second layer of approved top layer insulation installed as the final membrane substrate. Composite insulation panels may be used as a top layer placed with the polyisocyanurate side facing down. Anchor Sheet: One ply of GlasBase or Flintglas Premium Ply Sheet (Type Vi) mechanically attached as detailed below. Fastening. Anchor sheet shall be lapped 4" and fastened with 11 ga. annular ring shank nails and approved tin caps 8 "o.c. in the lap and three rows staggered in the center of the sheet 8 "o.c. Base Sheet One ply of Ultra Poly SMS, Glas Base, Flex -I Glas Base, Flex -I Glas FR Base or Poly SMS base adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs. /sq. Ply Sheet (Optional) One or more plies of Flintglas Ply Sheet (Type IV) or Flintglas Premium Ply Sheet (Type VI) adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs.sq. (j 011 ,X. 1 APPROVED NOA No.: 08- 0227.09 Expiration Date: 06/19/13 Approval Date: 05/15/08 Page 13 of 39 Membrane: Surfacing. One ply of Flintlastic GMS, Flintlastic Premium GMS, Flintlastic FR P, Flintlastic Premium FR -P, Flintlastic FR Cap sheet, Plexiglas Premium Cap 960, Ultra Poly SAM or Flintglas Mineral Surfaced Cap Sheet adhered to base/ply sheet with approved mopping asphalt applied within the EVT range and at a rate of 20 to 40 lbssq. or Flintlastic GTS torch adhered to base/ply sheet. (Optional) Install one of the following: 1. 400- lb. /sq. gravel or 300- lb. /sq. slag in a flood coat of approved mopping asphalt at an application rate of 60lbsq. 2. Karnak 97, FlintCoat A -150, APOC 212 Fibrated Aluminum, Henry 520 Aluminum or Grundy AL MB at an application rate of 1 1/2 gal. /sq. Maximum Design Pressure: -60psf. (See General Limitation #7) NOA No.: 08-0227.09 Expiration Date: 06/19/13 Approval Date: 05/15/08 Page 14 of 39 Membrane Type: Deck Type 11: Deck Description: System Type A(7): APP MODIFIED Wood, Insulated, New construction Minimum 19/32' thick plywood attached using wood screws spaced 6" o.c. at wood joists spaced maximum 24" o. c. Anchor sheet mechanically fastened; all layers of insulation adhered with approved asphalt. All General and System Limitations apply. One or more layers of any of the following insulations. Insulation Layer Pyrox Minimum 1.3" thick Insulation Fasteners Fastener (Table 3) Density/f 2 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A ACFoam -l1, lJltraGard Gold, ENRGY -2, ENRGY -3, PSI -25, FtintBoard ISO Minimum 1.5" thick N/A Fiberglas Minimum 15/16" thick Polite Minimum %" thick High Density Wood Fiberboard Minimum W' thick Dens -Deck MinimumW' thick Note: All insulation shall be adhered to the anchor sheet in full mopping of approved hot asphalt within the EVT range and at a rate of 20-40 lbs/100 ft2. Please refer to Roofing Application Standard RAS 117 for Insulation attachment. Insulation listed as base layer only shall be used only as base layers with a second layer of approved top layer insulation installed as the final membrane substrate. Composite insulation panels may be used as a top layer placed with the polyisocyanurate side facing down. Anchor Sheet One ply of GlasBase, Flex I-Glas Base, Flex-1 Glas FR Base or All Weather/ Empire Base sheet mechanically attached as detailed below. Fastening: Base Sheet: Ply Sheet: Anchor sheet shall be lapped 4" and fastened with Simplex Mega Cap Nails spaced 9" o.c. in the lap and the 9" o.c. in two staggered rows in the center of the sheet. One Ply of products listed under `Anchor Sheet' above adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20- 401bs. /sq. (Optional) One or more plies of Flintglas Ply Sheet (type IV) or Flintglas Premium Ply Sheet (type VI) adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20- 401bs. /sq. NOA No.: 08- 0227.09 Expiration Date: 06/19/13 Approval Date: 05/15/08 Page 15 of 39 Membrane: Flintlastic STA, Flintlastic STA Plus 5.0, Flintlastic Diamond GTA, Flintlastic GTA or GTA-FR torch adhered to base/ply sheet. Surfacing: (Optional) Install one of the following. 1. 400-lb./sq. gravel or 300- 1b. /sq. slag in a flood coat of approved mopping asphalt at an application rate of 601bsq. 2. Karnak 97, FlintCoat A -150, APOC 212 Fibrated Aluminum, Henry 520 Aluminum or Grundy AL MB at an application rate of 1 '1z gal. /sq. Maximum Design Pressure: - 60psf. (See General Limitation #7) A∎ _,.fix «.ir,.�./ !APPROVED; NOA No.: 08- 0227.09 Expiration Date: 06/19/13 Approval Date: 05/15/08 Page 16 of 39 Membrane Type: SBS MODIFIED Deck 'Type 11: Wood, Insulated, New Construction Deck Description: Minimum 1962" thick plywood attached using wood screws spaced 6" o.c. at word joists spaced maximum 24" o.c. System Type A(8): Anchor sheet mechanically fastened; all layer of insulation adhered with approved asphalt All General and System Limitations apply. One or more layers of any of the following insulations. Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 Pyrox Minhnum 1.3" thick NIA N/A ACFoam -II, UltraGard Gold, ENRGY -2, PSI -25, FlmtBoard ISO Minhnum 1.5" thick N/A N/A Fiberglas Minimum 1546" thick N/A N/A Perlite Minimum 3/' thick N/A . N/A IRgh Density Wood Fiberboard Minimum /a" thick N/A N/A Dens -Deck Minimum 1/a" thick N/A N/A Note: All insulation shall be adhered to the anchor sheet in full mopping of approved hot asphalt within the EVT range and at a rate of 20-40 Ibs/100 ft2. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulation listed as base layer only shall be used only as base layers with a second layer of approved top layer insulation installed as the final membrane substrate. Composite insulation panels may be used as a top layer placed with the polyisocyanurate side facing down. Anchor Sheet One ply of GlasBase, Flex -I Glas Base, Flex -I- Glas FR Base or All Weather/ Empire Base Sheet mechanically attached as detailed below. Fastening: Base Sheet Ply Sheet: Anchor sheet shall be lapped 4" and fastened with Simplex Mega Cap Nails spaced 9" o.c. in the lap and the 9" o.c. in two staggered rows in the center of the sheet. One ply of products listed under `Anchor Sheet' above adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20- r401bs. /sq. (Optional) One or more plies of Flintglas Ply Sheet (type IV) or Flintglas Premium Ply Sheet (Type VI) adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs. /sq. NOA No.: 08-0227.09 Expiration Date: 06/19/13 Approval Date: 05/15108 Page 17 of 39 Membrane: One ply of Flintlastic GMS, Plintlastic Premium GMS, Flintlastic FR P, Flintlastic Premium FR -P, Flintlastic FR Cap sheet, Plexiglas Premium Cap 960, Ultra Poly SMS or Flintglas Mineral Surfaced Cap Sheet adhered to base/ply sheet with approved mopping asphalt applied within the EVT range and at a rate of 20 to 40 Ibs./sq. or Plintlastic GTS torch adhered to base/ply sheet. Surfacing: (Optional) Install one of the following. 1. 400- lb. /sq. gravel or 300-1b./sq. slag in a flood coat of approved mopping asphalt at an application rate of 60lbsq. 2. Karnak 97, FlintCoat A -150, APOC 212 Fibrated Aluminum, Henry 520 Aluminum or Grundy AL MB at an application rate of 1 V2 gal. /sq. Maximum Design Pressure: - 60psf. (See General Limitation #7) NOA No.: 08- 0227.09 Expiration Date: 06/19/13 Approval Date: 05115/08 Page 18 of 39 Membrane Type: APP MODIFIED Deck Type 11: Wood, Insulated, New Construction Deck Description: 19/32" or greater plywood or wood plank System Type B(1): Base layer of insulation mechanically attached, optional top layer adhered with approved asphalt. All General and System Limitations apply. one or more layers of any of the following insulations under those listed as Top Layer: Base Insulation Layer Insulation Fasteners (Table 3) Pyrox Minimum 1.3" thick ENRGY -2, PSI -25 Minimum 1.4" thick ACFoam -II, UltraGard Gold, FlintBoard ISO Minimum 1.5" thick Fiberglas Minimum 15/16" thick Perlite Minimum 3" thick High Density Wood Fiberboard .Minimum W' thick Dens -Deck Minimum W' thick Any approved fasteners in Table 3 Any approved fasteners in Table 3 Any approved fasteners in Table 3 Any approved fasteners in Table 3 Any approved fasteners in Table 3 Any approved fasteners in Table 3 Any approved fasteners in Table 3 Fastener Density/ft2 1 :2 ft2 1:2ft2 1 :2 ft2 1:2 ft2 1:2 ft2 1:2ft2 1:2 ft2 Note: Base layer shall be mechanically attached with fasteners and density described above. Insulation panels listed are minimum sizes and dimensions; if larger panels are used the number of fasteners per board shall be increased maintaining the same fastener density (See Roofing Application Standard RAS 117 for fastening details). Top Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 Any of the insulations listed for Base Layer Note: Optional top layer of insulation shall be adhered with approved hot asphalt within the EVT range and at a rate of 20-40 lbs/100 ft2. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Composite insulation boards used as a top layer shall be installed with the polylsocyanurate face down. Base Sheet: One ply of GlasBase, Flex -I Glas Base, Flex -I Glas FR Base, Poly SMS, Flintglas Ply Sheet (Type IV) or Flintglas Premium Ply Sheet (Type VI) adhered to the insulated substrate with approved mopping asphalt applied within the EVT range and at a rate of 20- 40lbs./sq. NOA No.: 08- 0227.09 Expiration Date: 06119/13 Approval Date: 05 /15/08 Page 19 of 39 Ply Sheet (Optional) One ply of Glas Base, Flex- I -Glas Base, Flex I-Glas FR Base, Po1ySMS or one or more plies of Flintglas Ply Sheet (Type IV) or Flintglas Premium Ply Sheet (Type VI) adhered to the base sheet in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs sq. Membrane: Flintlastic STA, Flintlastic STA Plus 5.0, Flintlastic Diamond GTA, Flintlastic GTA or GTA-PR torch adhered to base or ply sheet. Surfacing: (Optional) Install one of the following: 1. 400- 1b./sq. gravel or 3001b. /sq. slag in a flood coat of approved mopping asphalt at an application rate of 60 lb./sq. 2. Karnak 97, FlintCoat A -150, APOC 212 Fibrated Aluminum, Henry 520 Aluminum or Grundy AL MB at an application rate of 1 y gal. /sq. Maximum Design Pressure: - 45psf. (See General Limitation #9) APPROVED NOA No.: 08- 0227.09 Expiration Date: 06/19/13 Approval Date: 05/15/08 Page 20 of 39 Membrane Type: SBS MODIFIED Deck Type 1I: Wood, Insulated, New Construction Deck Description: 19/32" or greater plywood or wood plank System Type B(2): Base layer of insulation mechanically attached, optional top layer adhered with approved asphalt. All General and System Limitations apply. One or more layers of any of the following insulations under those listed as Top Layer: Base Insulation Layer Pyrox Minimum 13" thick ENRGY -2, PSI -25 Minimum LA" thick ACFoana -II, UltraGard Gold, FliintBoard ISO Minimum 1.5" thick Fiberglas Minim an is/16 thick Perlite Minimum 334" thick High Density Wood Fiberboard Minhnum W' thick Dens -Deck Minimum VP thick Insulation Fasteners Fastener (Table 3) Density/ft2 Any approved fasteners in Table 3 1:2 ft2 Any approved fasteners in Table 3 1:2 ft2 Any approved fasteners in Table 3 1 :2 ft2 Any approved fasteners in Table 3 1:2 ft2 Any approved fasteners in Table 3 1:2 ft2 Any approved fasteners in Table 3 1:2 ft2 Any approved fasteners in Table 3 1 ft2 Note: Base layer shall be mechanically attached with fasteners and density described above. Insulation panels listed are minimum sizes and dimensions; if larger panels are used the number of fasteners per board shall be increased maintaining the same fastener density (See Roofing Application Standard RAS 117 for fastening details). Top Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 Any of the insulations listed for Base Layer Note: Optional top layer of insulation shall be adhered with approved hot asphalt within the EVT range and at a rate of 20-40 lbs/100 ft2. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Composite insulation boards used as a top layer shall be installed with the polyisocyanurate face down. Base Sheet: One ply of Glas Base, Flex -I Glas Base, Flex -I Glas FR Base, Poly SMS, Flintglas Ply Sheet (Type IV) or Flintglas Premium Ply Sheet (Type VI) or Ultra Poly SMS adhered to the insulated substrate with approved mopping asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. NOA No.: 08- 0227.09 Expiration Date: 06/19/13 Approval Date: 05 /15108 Page 21 of 39 Ply Sheet: (Optional) One ply of Glas Base, Flex -I -Glas Base, Flex I-Glas FR Base, PoIySMS or one or more plies of Flintglas Ply Sheet (Type IV) or Flintglas Premium Ply Sheet (Type VI) adhered to the base sheet in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. Membrane: One ply of Flintlastic GMS, Flintlastic Premium GMS, Flintlastic FR -P, Flintlastic Premium FR P, Flintlastic FR Cap sheet, Plexiglas Premium Cap 960, Ultra Poly SMS or Flintglas Mineral Surfaced Cap Sheet adhered to base/ply sheet with approved mopping asphalt applied within the EVT range and at a rate of 20 to 40 lbs. /sq. or Flintlastic GTS torch adhered to base/ply sheet. Surfacing: (Optional) Install one of the following: 1. 400- Ib./sq. gravel or 300- 1b. /sq. slag in a flood coat of approved mopping asphalt at an application rate of 60 lb./sq. 2. Karnak 97, FlintCoat A -150, APOC 212 Fibrated Aluminum at an application rate of 1.5 gal /sq. Maximum Design Pressure: 415psf. (See General Limitation #9) APPRCVED NOA No.: 08.227.09 Expiratloa Date: 06/19/13 Approval Date: 05 /15/08 Page 22 of 39 Membrane Type: Deck Type 1I: Deck Description: System Type C(1): APP MODIFIED Wood, Insulated, New Construction 19/32" or greater plywood Or wood plank All layers of insulation simultaneously attached. All General and System Limitations apply. One or more layers of any of the following insulations: Base Insulation Layer Insulation Fasteners (Table 3) Pyrox Minimum 1.3" thick ACFoam -II, UltraGard Gold, ENRG'Y -2, PSI -25, FlintBoard ISO Minimum 1.5" thick Fiberglas Minimum 1%6" thick Perlite Minimum 3/4" thick High Density Wood Fiberboard Minimum W' thick Dens -Deck Minimum W' thick NIA N/A N/A N/A N/A N/A Note: All layers shall be simultaneously fastened; see top layer below for fasteners and density. Top Insulation Layer Perlite Minimum 34" thick High Density Wood Fiberboard Minimum W' thick Dens -Deck Minimum 1/4" thick Fastener Density/ftz N/A N/A N/A N/A N/A N/A Insulation Fasteners Fastener (Table 3) Density/ft2 Any approved fasteners in Table 3 1:2 ft2 Any approved fasteners in Table 3 1:2 ft2 Any approved fasteners in Table 3 1 :2 ft2 Note: All layers of insulation shall be mechanically attached using the fastener density listed above. The insulation. panels listed are minimum sizes and dimensions; if larger panels are used, the number of fasteners shall be increased maintaining the same fastener density. Insulation fasteners shall be tested for withdrawal resistance in compliance with Testing Application Standard TAS 105 to confirm compliance with the wind load requirements. Please refer to Rooimg Application Standard RAS 117 for insulation attachment. NOA No.: 08-0227.09 Expiration Date: 06/19/13 Approval Date: 05 /15/08 Page 23 of 39 Base Sheet One ply of Glas Base, Flex I Glas Base, Flex -I Glas FR Base, Poly SMS, Flintglas Ply Sheet (Type IV) or Flintglas Premium Ply Sheet (Type VI) adhered to the insulated substrate with approved mopping asphalt applied within the EVT range and at a rate of 2040 lbs./sq. Ply Sheet (Optional) One ply of Glas Base, Flex -I -Glas Base, Fiex- I -Glas FR Base, Po1ySMS or one or more plies of Flintglas Ply Sheet (Type IV) or Flintglas Premium Ply Sheet (Type VI) adhered to the base sheet in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. Membrane: Flintlastic STA, Flintlastic STA Plus 5.0, Flintlastic Diamond GTA, Flintlastic GTA or GTA-FR torch adhered to base or ply sheet. Surfacing: (Optional) Install one of the following: 1. 400- 1bdsq. gravel or 300-lb./sq. slag in a flood coat of approved mopping asphalt at an application rate of 60 lb./sq. 2. Karnak 97, FlintCoat A -150, APOC 212 Ribrated Aluminum, Henry 520 Aluminum or Grundy AL MB at an application rate of 1 '/x gal. /sq. Maximum Design Pressure: -45psf. (See General Limitation #9) NOA No.: 08- 0227.09 Expiration Date: 96/19/13 Approval Date: 05/15108 Page 24 of 39 Base Sheet One ply of Glas Base, Flex4 Glas Base, Flex -1 Glas FR Base, Poly SMS, Fl t Ply Sheet (Type IV) or Flintglas Premium Ply Sheet (Type VI) or Ultra Poly SMS adhered to the insulated substrate with approved mopping asphalt applied within the RVVT range and at a rate of 20-40 lbs.sq. Ply Sheet (Optional) One ply of Glas Base, Flex -I -Glas Base, Flex -I -Glas FR Base, PoIySMS or one or more plies of Flintglas Ply Sheet (Type IV) or Flintglas Premium Ply Sheet (Type VI) adhered to the base sheet in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. Membrane: One ply of Flintlastic GMS, Flintlastic Premium GMS, Flintlastic FR P, Flintlastic Premium FR -P, Flintlastic FR Cap sheet, Plexiglas Premium Cap 960, Ultra Poly SMS or Flintglas Mineral Surfaced Cap Sheet adhered to base/ply sheet with approved mopping asphalt applied within the EVT range and at a rate of 20 to 40 lbsdsq. or Flintlastic GTS torch adhered to base/ply sheet. Surfacing: (Optional) Install one of the following. 1. 400- 1bisq. gravel or 300- Ib./sq. slag in a flood coat of approved mopping asphalt at an application rate of 60 lb. /sq. 2. Karnak 97, F1intCoat A-150, APOC 212 Fibrated Aluminum at an application rate of 1.5 galfsq. Maximum Design Pressure: - 45psf. (See General Limitation #9) NOA No.: 08- 0227.09 Expiration Date: 06/19/13 Approval Dater 05115/08 Page 26 of 39 Membrane Type: Deck Type 11: Deck Description: System Type C(2): SBS MODIFIED Wood, Insulated, New Construction 19/32" or greater plywood or wood plank All layers of insulation simultaneously attached. All General and System Limitations apply. One or more layers of any of the following insulations under those listed as Top Layer: Base insulation Layer Insulation Fasteners (Table 3) Pyrox Minimum 1.3" thick ACFoani -II, UltraGard Gold, ENRGY -2, PSI -25, FlintBoard ISO Minimum 1.5" thick Fiberglas Minimum' /16 thick Perlite Minimum %" thick High Density Wood Fiberboard Minimum Va" thick Dens -Deck Minimum 1/4" thick Fastener Density /ft2 N/A N/A N/A N/A N/A N/A NIA N/A N/A N/A N/A N/A Note: All layers shall be simultaneously fastened; see top layer below for fasteners and density. Top Insulation Layer Perlite Minimum 34" thick High Density Wood Fiberboard Minimum Vz" thick Dens -Deck Minimum W' thick Insulation Fasteners Fastener (Table 3) Density /ftz Any approved fasteners in Table 3 1:2 ft2 Any approved fasteners in Table 3 1 :2 ft2 Any approved fasteners in Table 3 1:2 ft2 Note: All layers of insulation shall be mechanically attached using the fastener density listed above. The insulation panels listed are minimum sizes and dimensions; if larger panels are used, the number of fasteners shall be increased maintaining the same fastener density. Insulation fasteners shall be tested for withdrawal resistance in compliance with Testing Application Standard TAS 105 to confirm compliance with the wind load requirements. Please refer to Roofing Application Standard RAS 117 for insulation attachment. a NOA No.: 08- 0227.09 Expiration Date: 06119113 Approval Date: 05/15/08 Page 25 of 39 Membrane Type: Deck Type 11: Deck Description: System Type D(1): APP MODIFIED Wood; Insulated, New Construction 19/' or greater plywood or wood plank All layers of insulation and base sheet simultaneously attached. All General and System Limitations apply. One or more layers of any of the following insulations: Insulation Layer Insulation Fasteners (Table 3) .Fastener Density/ft2 Pyrox Minimum 1.Y' thick N/A N/A ACFoam -II, UltraGard Gold, ENRGY -2, PSI -2S, FlintBoard ISO Minimum 1.5" thick N/A N/A Fiberglas Minimum 15/16" thick N/A N/A Periite Minimum Ve thick N/A N/A High Density Wood Fiberboard Minimum W' thick N/A N/A Dens -Deck Minimum V%" thick N/A N/A Note: Top layer shall have preliminary attachment, prior to the installation of the base/anchor sheet, at an application rate of two fasteners per board for insulation boards having no dimension greater than 4 ft., and four fasteners for any insulation board having no dimension greater than 8 ft. All layers of insulation and base sheet shall be simultaneously fastened. See base/anchor sheet below for fasteners and density. Base Sheet: Fastening #1: Fastening #2: Fastening #3: APPROVED One ply of Glas Base, Flex -I Glas Base, Flex -I Glas FR Base or Poly SMS base mechanically attached as detailed in Fastening #1, below or one ply of Poly SMS mechanically attached as detailed in Fastening.#2 or #3, below. Olympic Screws #12 or #14 and metal plates, Dekfast #14 or #15 and metal plates, Tru-Fast #12 or #14 and MP -3 Plates or SFS Insul Fixx #12 or #14 and metal plates spaced 4" o.c. at a 4" side lap and two staggered rows in the center of the sheet, 24" o.c. Olympic Screws #12 or #14 and metal plates, Dekfast #14 or #15 and metal plates, Tru-Fast #12 or #14 and MP -3 Plates or SFS Insul F xx #12 or #14 and metal plates spaced 12" o.c. at a 4" side lap and two staggered rows in the center of the sheet, 36" o.c. Tru -Fast #12 or #14 and 2" metal plates or SFS Insul-Fixx screws and 2" round metal plates at a 4" side lap, 12" o.c. NOA No.: 08- 0227.09 Expiration Date: 06/19/13 Approval Date: 05/15/08 Page 27 of 39 Ply Sheet (Optional) One ply of Glas Base, Flex - I-Glas Base, Flex- I -Glas FR Base, Po1ySMS or one or more plies of Flintglas Ply Sheet (Type IV) or Flintglas Premium Ply Sheet (Type VI) adhered to the base sheet in a full mopping of approved asphalt applied within the BVT range and at a rate of 20-40 lbs. /sq. Membrane: Flintlastic STA, Flintlastic STA Plus 5.0, Flintlastic Diamond GTA, Flintlastic GTA or GTA -FR torch adhered to base or ply sheet. Surfacing: (Optional) Install one of the following: 1. 400 - lb./sq. gravel or 300- lbisq. slag in a flood coat of approved mopping asphalt at an application rate of 60 lb./sq. 2. Karnak 97, FlintCoat A -150, APOC 212 Fibrated Aluminum, Henry 520 Aluminum or Grundy AL MB at an application rate of 1 %z gal. /sq. Maximum Design Pressure: - 45psf. (See General Limitation #9) AP PROM 1 NOA No.: 08- 0227.09 Expiration Date: 06/19/13 Approval Date: 05/15/08 Page 28 of 39 Membrane Type: Deck Type 1I: Deck Description: System Type D(2): SBS MODIFIED Wood, Insulated, New Construction 19/' or greater plywood or wood plank All layers of insulation and base sheet simultaneously attached. All General and System Limitations apply. One or more layers of any of the following insulations: Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 Pyrox Minimum 1.3" thick N/A N/A ACFoam -II, UltraGard Gold, ENRGY•2, PSI -25, FIintBoard ISO Minimum 1.5" thick N/A N/A Fiberglas Minimum x /16" thick N/A N/A Perlite Minimum 3R' thick N/A N/A High Density Wood Fiberboard Minimum W' thick N/A N/A Dens -Deck Minimum 1/4" thick N/A N/A Note: Top layer shall have preliminary attachment, prior to the installation of the base/anchor sheet, at an application rate of two fasteners per board for insulation boards having no dimension greater than 4 ft., and four fasteners for any insulation board having no dimension greater than 8 ft. All layers of insulation and base sheet shall be simultaneously fastened. See base /anchor sheet below for fasteners and density. Base Sheet: Fastening #1: Fastening #2: Fastening #3: One ply of Glas Base, Flex -I Glas Base, Flex -I Glas FR Base or Poly SMS base mechanically attached as detailed in Fastening #1, below or one ply of Poly SMS. mechanically attached as detailed in Fastening #2 or #3, below. Olympic Screws #12 or #14 and metal plates, Dekfast #14 or #15 and metal plates, Tru-Fast #12 or #14 and MP -3 Plates or SFS Insul-Fixx #12 or #14 and metal plates spaced 4" o.c. at a 4" side lap and two staggered rows in the center of the sheet, 24" o.c. Olympic Screws #12 or #14 and metal plates, Dekfast #14 or #15 and metal plates, Tru-Fast #12 or #14 and MP -3 Plates or SFS Insul -Fixx #12 or #14 and metal plates spaced 12" o.c. at a 4" side lap and two staggered rows in the center of the sheet, 36" o.c. Tru-Fast #12 or #14 and 2" metal Plates or SFS Insul -Fixx screws and 2" round metal plates at a 4" side lap, 12" o.c. NOA No.: 08. 4227.09 Expiration Date: 06/19/13 Approval Date: 05/15/08 Page 29 of 39 Ply Sheet: Membrane: (Optional) One ply of Glas Base, Flex -I -Glas Base, Flex- I -Glas FR Base, Po1ySMS or one or more plies of Flintglas Ply Sheet (Type IV) or Flintglas Premium Ply Sheet (Type VI) or Ultra Poly SMS adhered to the base sheet in a full mopping of approved asphalt applied within the EVT range and at a rate of 20- 40lbs.sq. One ply of Flintlastic GMS, Flintlastic Premium GMS, Flintlastic FR P, Flintlastic Premium FR -P, Flintlastic FR. Cap Sheet, Plexiglas Premium Cap 960 or Ultra Poly SMS adhered to ply sheet with approved mopping asphalt applied within the EVT range and at a rate of 20 to 40 lbs. /sq. or Flintlastic GTS torch adhered to ply sheet. • Surfacing: (Optional) Install one of the following: 1. 400- 1b./sq. gravel or 300- 1b. /sq. slag in a flood coat of approved mopping asphalt at an application rate of 60lb./sq. 2. Karnak 97, FlintCoat A -150, APOC 212 Fibrated Aluminum at an application rate of 1.5 gal./sq. Maximum Design Pressure: - 45psf. (See General Limitation #9) NOA No.: 08.0227.09 Expiration Date: 06/19/13 Approval Date: 05/15/08 Page 30 of 39 Membrane Type: APP MODIFIED Deck Type 1: Wood, Non - insulated Deck Description: 19 /' or greater plywood or wood plank decks System Type E(1): Base sheet mechanically fastened. All General and System Limitations apply. Base Sheet: One ply of Glas Base, Flex -I Glas Base, Flex -I Glas FR Base or Poly SMS base mechanically attached as detailed below. Fastening: Base sheet shall be lapped 4" and fastened with approved roofing nails and tin caps 9 ". o.c. hi the lap and two rows staggered in the center of the sheet 12" o.c. Ply Sheet: (Optional) One ply of Glas Base, Flex - I-Glas Base, Flex - I-Glas FR Base, PolySMS or one or more plies of Flintglas Ply Sheet (Type IV) or Flintglas Premium Ply Sheet (Type VI) adhered to the base sheet in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs. /sq. Membrane: Flintlastic STA, Flintlastic STA Plus 5.0, Flintlastic Diamond GTA, Flintlastic GTA or GTA-FR torch adhered to base or ply sheet. Surfacing: (Optional) Install one of the following. 1. 400- lb /sq. gravel or 300-1b./sq. slag in a flood coat of approved mopping 'asphalt at an application rate of 60 lb. /sq. 2. Karnak 97, FlintCoat A -150, APOC 212 Fibrated Aluminum, I-lenry 520 Aluminum or Grundy AL MB at an application rate of 1'/z gal. /sq. Maximum Design Pressure: 45psf. (See General Limitation #9) IAPPROVED1 NOA No.: 08- 0227.09 Expiration Date: 06/19///133 Approval Date: 05)15! 08 Page 31 of 39 Membrane Type: SBS MODIFIED Deck Type 1: Wood, Non - insulated Deck Description: 19/32" or greater plywood or wood plank decks System Type E(2): Base sheet mechanically fastened. All General and System Limitations apply. Anchor Sheet One ply of Glas Base, Flex -I Glas Base, Flex -I Glas FR Base or Poly SMS base mechanically fastened as detailed below. Fastening: Base sheet shall be lapped 4" and fastened with approved roofing nails and tin caps 9 "o.c. in the lap and two rows staggered in the center of the sheet 12 "o.c. Ply Sheet (Optional) One ply of Glas Base, Flex -I -Glas Base, Flex -1 -Glas FR Base, Po1ySMS or one or more plies of Flintglas Ply Sheet (Type IV) or Flintglas Premium Ply Sheet (Type VI) or Ultra Poly SMS adhered to the base sheet in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. Membrane:. One ply of Flintlastic GMS, Flintlastic Premium GMS, Flintlastic FR P, Flintlastic Premium FR -P, Flintlastic FR Cap sheet, Plexiglas Premium Cap 960, Ultra Poly SMS or Flintglas Mineral Surfaced Cap Sheet adhered to base/ply sheet with approved mopping asphalt applied within the EVT range and at a rate of 20 to 40 lbs./sq. or Flintlastic GTS torch adhered to base /ply sheet. Surfacing: (Optional) Install one of the following: 1. 400-lb./sq. gravel or 300-1b./sq. slag in a flood coat of approved mopping asphalt at an application rate of 60lb.sq. 2. Karnak 97, FlintCoat A -150 or APOC 212 Fibrated Aluminum at an application rate of 1.5 galisq. Maximum Design Pressure: -45 psf (See General Limitation #9) NOA No.: 08-0227.09 Expiration Date: 06/19/13 Approval Date: 05/15108 Page 32 of 39 Membrane Type: Deck Type 1: Deck Description: System Type E(3): APP MODIFIED Wood, Non - Insulated 1932" or greater plywood or wood plank Base sheet mechanically fastened. All General and System Limitations apply. Base Sheet Fastening: Ply Sheet Membrane: Surfacing: Maximum Design Pressure: One ply of Glas Base or Flintglas Premium Ply Sheet (Type VI) mechanically attached as detailed below. Base sheet shall be lapped 4" and fastened with 11 ga. annular ring shank nails and approved tin caps 8 "o.c. in the lap and three rows staggered in the center of the sheet 8 "o.c. (Optional) One ply of Ultra Poly SMS, Glas Base, Flex -I Glas Base, Flex -I Glas FR Base or Poly SMS or one or more plies of Flintglas Ply Sheet (Type IV) or Flintglas Premium Ply Sheet (Type VI) adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. Flintlastic STA, Flintlastic STA Plus 5.0, Flintlastic Diamond GTA, Flintlastic GTA or GTA-FR torch adhered to base/ply sheet. (Optional) Install one of the following: 1. 400 -1bsq. gravel or 300- lb. /sq. slag in a flood coat of approved mopping asphalt at an application rate of 601b, /sq. 2. Karnak 97, FlintCoat A -150, APOC 212 Fibrated Aluminum, Henry 520 Aluminum or Grundy AL MB at an application rate of 1 Vz gal. /sq. -52.5 psf (See General Limitation #7) NOA No.: 08-0227.09 Expiration Date: 06/19/13 Approval Date: 05/15/08 Page 33 of 39 Membrane Type: Deck Type 11: Deck Description: System Type E(4): SBS MODIFIED Wood, Non - Insulated 19132" or greater plywood or wood plank Base sheet mechanically fastened. All General and System Limitations apply. Base Sheet: Fastening: Ply Sheet: Membrane: Surfacing. Maximum Design Pressure: One ply of Glas Base or Flintglas Premium Ply Sheet (Type VI) mechanically attached as detailed below. Base sheet shall be lapped 4" and fastened with 11 ga. annular ring shank nails and approved tin caps 8 "o.c. in the lap and theme rows staggered in the center of the sheet 8 "o.c. (Optional). One ply of Ultra Poly SMS, Glas Base, Flex -I Glas Base, Flex -I Glas FR Base or Poly SMS or one or more Flintglas Ply Sheet (Type IV) or Flintglas Premium Ply Sheet (Type VI) adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20- 40lbs. /sq. One ply of Flintlastic GMS, Flintlastic Premium GMS, Flintlastic FR -P, Flintlastic Premium FR -P, Flintlastic FR Cap sheet, Plexiglas Premium Cap 960, Ultra Poly SMS or Flintglas Mineral Surfaced Cap Sheet adhered to base/ply sheet with approved mopping asphalt applied within the EVT range and at a rate of 20 to 40 lbs.sq. or Flintlastic GTS torch adhered to base/ply sheet. (Optional) Install one of the following. 1. 400- lb. /sq. gravel or 300- lb. /sq. slag in a flood coat of approved mopping asphalt at an application rate of 60lbsq. 2. Karnak 97, FlintCoat A -150, APOC 212 Fibrated Aluminum, Henry 520 Aluminum or Grundy AL MB at an application rate of 11 gal. /sq. -52.5 psf (See General Limitation #7) NOA No.: 08- 0227.09 Expiration Date: 06/19/13 Approval Date: 05/15/08 Page 34 of 39 Membrane Type: APP MODIFIED Deck Type 1: Wood, Non - Insulated Deck Description: Minimum 19/32" thick plywood attached using approved nails spaced 4" o.c. at wood joists spaced maximum 24" o. c. System Type E(5): Base sheet mechanically fastened. All General and System Limitations apply. Base Sheet: One ply of GlasBase or Flintglas Premium Ply Sheet (Type VI) mechanically attached as detailed below. Fastening: Base sheet shall be lapped 4" and fastened with 11 ga. annular ring shank nails and approved tin caps 8 "o.c. in the lap and three rows staggered in the center of the sheet 8 "o.c. Ply Sheet (Optional ) One ply of Ultra Poly SMS, Glas Base, Flex -I Glas Base, Flex -I Glas FR Base or Poly SMS or one or more Flintglas Ply Sheet (Type IV) or Flintglas Premium Ply Sheet (Type VI) adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20- 40lbs. /sq. Membrane: Flintlastic STA, Flintlastic STA Plus 5.0, Flintlastic Diamond GTA, Flintlastic GTA or GTA -FR torch adhered to base or ply sheet. Surfacing: (Optional) Install one of the following: 1. 400- lb /sq. gravel or 300-lb./sq. slag in a flood coat of approved mopping asphalt at an application rate of 60 lbisq. 2. Karnak 97, FlintCoat A -150, APOC 212 Fibrated Aluminum, Henry 520 Aluminum or Grundy AL MB at an application rate of 1 Y2 gal. /sq. Maximum Design Pressure: - 60psf. (See General Limitation #7) APPROVED NOA No.: 08-0227.09 Expiration Date: 06/19/13 Approval Date: 05/15/08 Page 35 of 39 Membrane Type: SBS MODIFIED Deck Type 1: Wood, Non - Insulated Deck Description: Minimum 19/32" thick plywood attached using approved nails spaced 4" o.c. at wood joists spaced maximum 24" o. c. System Type E(6): Base sheet mechanically fastened. All General and System Limitations apply. Base Sheet: One ply of GlasBase or Flintglas Premium Ply Sheet (Type VI) mechanically attached as detailed below. Fastening: Base sheet shall be lapped 4" and fastened with 11 ga. annular ring shank nails and approved tin caps 8 "o.c. in the lap and three rows staggered in the center of the sheet 8" o.c. Ply Sheet: (Optional) One ply of Ultra Poly SMS, Glas Base, Flex -I Glas Base, Flex -I Glas FR Base or Poly SMS or one or more Flintglas Ply Sheet (Type IV) or Flintglas Premium Ply Sheet (Type VI) adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 Ibs./sq. Membrane: One ply of Flintlastic GMS, Flintlastic Premium GMS, Flintlastic FR P, Flintlastic Premium FR -P, Flintlastic FR Cap sheet, Plexiglas Premium Cap 960, Ultra Poly SMS or Flintglas Mineral Surfaced Cap Sheet adhered to base/ply sheet with approved mopping asphalt applied within the EVT range and at a rate of 20 to 40 lbs.sq. or Flintlastic GTS torch adhered to base/ply sheet. Surfacing: (Optional) Install one of the following. 1. 400-lb./sq. gravel or 300- lb. /sq. slag in a flood coat of approved mopping asphalt at an application rate of 60 lbisq. 2. Karnak 97, FlintCoat A -150, APOC 212 Fibrated Aluminum, Henry 520 Aluminum or Grundy AL MB at an application rate of 1 Vz gal. /sq. Maximum Design Pressure: -60psf. (See General Limitation #7) wllilv��i7L1.j x�':•i 1 %i il.I '� -°-•- !APPROVED NOA No.: 08-0227.09 Expiration Date: 06/19/13 Approval Date: 05/15/08 Page 36 of 39 Membrane Type: APP MODIFIED Deck Type 1: Wood, Non - insulated Deck Description: Minimum 19/32" thick plywood attached using wood screws spaced 6 "o.c. at wood joists spaced maximum 24" o.c. System Type E(7): Base sheet mechanically fastened. All General and System Limitations apply. Base Sheet: One ply of Glas Base, Flex -I Glas Base, Flex -I Glas FR Base or All Weather / Empire Base Sheet mechanically fastened as detailed below. Fastening: Base sheet shall be lapped 4" and fastened with Simplex Mega Cap Nails spaced 9"o.c. in the lap and 9" o.c. in two staggered rows in the center of the sheet. Ply Sheet: (Optional) One ply of GlasBase, Flex -I- GlasBase, Flex - I-Glas FR Base, Po1ySMS or one or more plies of Flintglas Ply Sheet (Type IV) or Flintglas Premium Ply Sheet (Type Vi) adhered to the base sheet in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs.sq. Membrane: Flintlagtic STA, Flintlastic Diamond GTA, Flintlastic G'I'A or GTA -FR torch adhered to base or ply sheet. Surfacing: (Optional) Install one of the following: 1. 400- lb. /sq. gravel or 300- lb. /sq. slag in a flood coat of approved mopping asphalt at an application rate of 60 lbfsq. 2. Karnak 97, FlintCoat A -150, APOC 212 Fibrated Aluminum, Henry 520 Aluminum or Grundy AL MB at an application rate of 1 gal. /sq. Maximum Design Pressure: -60psf (See General Limitation #7) NOA No.: 08- 0227.09 Expiration Date: 06/19/13 Approval Date: 05/15/08 Page 37 of 39 Membrane Type: SBS MODIFIED Deck Type 1: Wood, Non - insulated Deck Description: Minimum 19/32' thick plywood attached using wood screws spaced 6 "o.c. at wood joists spaced maximum 24" o.c. System Type E(8): Base sheet mechanically fastened. All General and System Limitations apply. Base Sheet: One ply of GlasBase, Flex -I Glas Base, .Flex I Glas FR Base or All Weather/Bmpire Base Sheet mechanically fastened as detailed below. Fastening: Base sheet shall be lapped 4" and fastened with Simplex Mega Cap Nails spaced 9" o.c. in the lap and 9" o.c. in two staggered rows in the center of the sheet. Ply Sheet (Optional) One ply of GlasBase, Flex -I- GlasBase, Flex -I -Glas FR Base, Po1ySMS or one or more plies of Flintglas Ply Sheet (Type IV) or Flintglas Premium Ply Sheet (Type VI) or Ultra Poly SMS adhered to the base sheet in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. Membrane: One ply of Flintlastic GMS, Flintlastic Premium GMS, Flintlastic FR P, Flintlastic Premium FR -P, Flintlastic FR Cap sheet, Plexiglas Premium Cap 960, Ultra Poly SMS or Flintglas Mineral Surfaced Cap Sheet adhered to base/ply sheet with approved mopping asphalt applied within the EVT range and at a rate of 20 to 40 lbs. /sq. or Flintlastic GTS torch adhered to base/ply sheet. Surfacing: (Optional) Install one of the following. 1. 400- Ib.sq. gravel or 300-1b./sq. slag in a flood coat of approved mopping asphalt at an application rate of 60 lb. /sq. 2. Karnak 97, FlintCoat A -150 or APOC 212 Fibrated Aluminum at an application rate of 1.5 gal./sq. Maximum Design Pressure: - 60psf. (See General Limitation #7) NOA No.: 08- 0227.09 Expiration Date: 06/19/13 Approval Date: 05/15/08 Page 38 of 39 WOOD DECK SYSTEM LIMITATIONS: 1. A slip sheet is required with Ply 4 and Ply 6 when used as a mechanically fastened base or anchor sheet. GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance, refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Insulation -may be installed in multiple layers. The first layer shall be- attached incompliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq., or mechanically attached using the fastening pattern of the top layer 3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size shall be 4' x 4' maximum. 4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at each side lap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 12lbs. /sq. Note: Spot attached systems shall be limited to a maximum design pressure of -45 psi'. S. Fastener spacing for insulation attachment is based on a R+imiinum Characteristic Force (F) value of 275 lbf., as tested in compliance with Testing Application Standard TAS 105. If the fastener value, . as field - tested, are below 275 lbf. insulation attachment shall not be acceptable. 6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the fastener resistance be less than that required, as determined by the Building Official, a revised faster spacing, prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roof mg Application Standard RAS 117. 7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred within this NOA, General Limitation #9 will not be applicable.) 8. All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs shall conform to Roofing Application Standard RAS 111 and applicable wind load requirements. 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (Le. field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening atenhanced pressure zones (i.e. perimeters, extended corners and comers). When this limitation is specifically referred within this NOA, General Limitation #7 will not he applicable.) 10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9B-72 of the Florida Administrative Code. END OF THIS ACCEPTANCE NOA No.: 08- 0227.09 Expiration Data: 06119/13 Approval Date: 05/15/08 Page 39 of 39 PERMIT #: Miami Shores Viiiage Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 RECEIPT �11 -14°1 DATE: W� 1, i/Le?1r>,, ❑ Contractor ❑ Architect Picked up 2 sets of plans and (other) r\\ l lS-f Address: From the building department on this date in order to have corrections done to plans And /or get County stamps. I understand that the plans need to be brought back to Miami Shores Village Building Department to continue permitting process. Acknowledged PERMIT CLERK INITIAL: RESUBMITTED DATE: 1 1/0I PERMIT CLERK INITIAL: Permit No: 11 -1249 Job Name: July 15, 2011 Miami Shores Viiiage Building Department Building Critique Sheet 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 Page 1 of 1 1) Section C is incomplete. All sections must be done. 2) This permit will be double feed because affidavit submitted says work is complete. Plan review is not complete, when all items above are corrected, we will doa complete plan review. If any sheets are voided, remove them from the plans and replace with new revised sheets and include one set of voided sheets in the re- submittal drawings. Norman Bruhn CBO 305 - 795 -2204