RF-11-1156ip Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Inspection Number: INSP - 161364 Permit Number: RF -6 -11 -1156 Scheduled Inspection Date: August 03, 2011 Inspector: Bruhn, Norman Owner: STRONG, MICHAEL Job Address: 229 NE 101 Street Miami Shores, FL 33138 -2422 Project: <NONE> Contractor: EARL W JOHNSTON ROOFING, INC. Permit Type: Roof Inspection Type: Final Roof Work Classification: Tile /Flat Phone Number Parcel Number 1132060134790 Phone: 954- 989 -7794 Building Department Comments RESIDENTIAL TILE AND FLAT RE ROOF Passed Failed Correction Needed Re- Inspection Fee No Additional Inspections can be scheduled until re- inspection fee is paid. Inspector Comments c - August 02, 2011 For Inspections please call: (305)762 -4949 Page 27 of 47 ACB2 Engineering Inc. Testing & Engineering Services Certificate of Authorization# 8131 'el: 954 - 245.8976; Fax: 954.301.7776 P.O. Box 823612 Pembroke Pines, FL 33082 07/29/2011 Roof Tile Uplift Test Report Attention: Miami Shores Village, Building Division, 10050 NE 2 Avenue, Miami Shores FI 33138 Client: Earl W Johnston Test Date: 07/29/2011 Permit # RF -6-11 -1156 Property Address: Strong Residence 229 NE 101 Street, Miami Shores, FI Roof Pitch: Type of Tile: Roof Area: 3 1n 12 Entegra Roof Tile 23.00 squares Tile Attachment Method: Two Component Polyurethane Foam Adhesive -Poly Pro H 160 Field Instrument : IMADA Force Gauge 0 -10 Serial number: 243454 Test Location Perimeter Area: 10.00 sq Field Area: 13.00 sq No. of Corner. 10 Ridge Areas: 148 pcs Total Number of Tests Field Uplift Pull Test Test results 10 As per FBC 2007 13 As per FBC 2007 10 As per FBC 2007 13 As per FBC 2007 Important: Passed Passed Passed Passed These laboratory results can change due to future weather impacts and /or unavoidable roof traffic. Therefore, this report represents the TAS 106 results at the time of the test. Please see attached a Roof Sketch for this project. Cordially, ACB2 En 'g Inc. (NOA 09- 1005.01) Antonia ,�c. redo, PE Fla. R, g. No: 36466 !z12ttt ACB2 Engineering Inc. Engineering and Laboratory Services P.O. Box 823612 Pembroke Pines, Florida 33082 Phone: (954) 245 -8976 Fax: (954) 301 -7776 RE: Permit# R1:7-7) —I I —II51 Mami VoledfillAve aef2,0frategott 10050 NE 2nd Ave Miami Shores, Fl 33138 Phone 305-795-2204; Fax 305 -756 -8972 www.miamishoresvillage.com DATE: 146- ( 0 INSPECTION AFFIDAVIT I EARL a), 7 01v , 0 & I D A ) ROOi ht)G ctuRz4 licensed as a (n (Print name and circle License Type) FS 468 Building Inspe or License #: (C6067073 On or about / Engineer / Architect, / /2- Prr I did personally inspect the roof deck nailing and /or (Date & time) secondary water barrier work at 0,99 NE /0/ ,a7T 6 - l (Complete Job Site Address) Based upon that examination I have determined the installation was done according to the Hurricane Mitigation Retrofit Manual (Based on 553.844 F.S) State of Florida County of Dade: The undersigned, being the first duly sworn, deposes and says that he /she is the contractor for the above property mentioned. Sworn to and subscribed before me this day of" Notary Public, Sate of Florida at Large J J ✓ ME3 A. ROMEO MY COMMISSION 6 DD 788767 EXPIRES'. June 22, 2012 'rE6. nc a Bondedlluu Budge', Notary Services *General, Building, Residential, or Roofing Contractors or any individual certified under 468 F.S. to make such an inspection. Include photographs of each plane of the roof with permit # and address # clearly shown marked on the deck for each inspection Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 Permit No. °)---I Master Permit No. BUILDING PERMIT APPLICATION FOC 2004 JUN 242011 J :......................o Permit Type (circle): Building Electrical Plumbing Mechanical Owner's Name (Fee Simple Titleholder) HictiVia, N (- Owner's Address '2:2-q NE. 101 cty M i s Tenant/Lessee Name State Phone # 305-- /410 Del e� Zip333 Phone # Job Address (where the work is being done) City FOLIO / PARCEL # 2:2-41 i 101 6 ` c i" Miami Shores Village County Miami -Dade Is' dad 3- iip m i`3— 710 Building Historically Designated YES NO )4 Zip 3,'i 3'3 Contractor's Company Name. 1j %,,-r -e,1 3 i &I i f l Jc Phone # C ..-.cwc '7771 ll Contractor's Address 5111 revvV1 s i City liL irMil State V`t, Zip 330'2-3 Qpalifier Name 1 aint g d. art tri r Phone # ci m Li1C ._11 ti State Certificate or Registration No. CC-6-7 0 "b Certificate of Competency No. Architect/Engineer's Name (if applicable) Phone # Vdlue of Work For this Permit $ / Linear Footage & Work: -3"O Type of Work: ['Addition 1A1teration ['New ❑ Repair/Replace ❑ Demolition Describe Work: 1 cyehin A L P 4° ' P ow L, ********* ' * * * * * * * * * *** * * * * * * * * * * * * * * * * ** Fees************* * * * * * * *** * * * * * * *** * * * * * * * * * * * ** Submittal Fee $ Permit Fee $ CCF $ CO /CC Notary $ Training/Education Fee $ Technology Fee $ S4anning $ Radon $ DPBR $ Zoning $ Bond $ Code Enforcement $ Double Fee $ Structural Review. $ Total Fee Now Due $ See Reverse side ---> Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that_no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature Owner or Agent / Contractor The foregoing instrument was acknowledged before me this -) The foregoing instrument was acknowledged before me this day of j 0, , 20 I( , by Ml ckfAvi , day of (J u , 20 1 r , by Vel; who is personally known to me or who has produced who is personally known to me or who has produced As identification and who did take an oath. s 0".P;'B <<, MEG A. ROMEO MY COMMISSION # DD 788767 EXPIRES:. June 22, 2012 cried Thri Sud ei Notary Services Sign: Sign: Print: Print: My Commission . ).fires: 221 rt My Commission * * * * * * * * * * * * * * * * * * * * *** NOTARY PUBLIC: as identification and who did take an oath. NOTARY PUBLIC• ` ' (V ON # DD 788767i °'" APPLICATION APPROVED BY: (Revised 02/08/06) "I‘;.e-// ROMEO MY ESP: i. 3 22; 2012 es' Bonded T' •..c.ar/Services es: td nit I Plans Examiner Engineer Zoning NOTICE OF COMMENCEMENT A RECORDED COPY MUST BE POSTED ON THE JOB SITE AT TIME OF FIRST INSPECTION PERMIT NO. ff.-le-11-119U TAX FOLIO NO. 1 1- 32010 -O 3 -9190 STATE OF FLORIDA: COUNTY OF MIAMI -DADE: THE UNDERSIGNED hereby gives notice that improvements will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement. 1► 11111111111IIIIIIIIlIIIIIIIIIIIl111II1II III C F iN 2011R0413330 OR Bk 27734 Ps 3923; (fps) RECORDED 06/27/2011 12:05 :1 HARVEY RJYIN, CLERK OF COURT MIAMI-DADE COUNTY: FLORIDA LAST PAGE n� °� n �1 Space above reserved for use of recording office 1. Legal description of property and treet/address: m) Amt Sr ivy"- €S SE C.. 1— j� �Y\ 0 No (®- 70 LOT 15 4- ra h(AL S_ 2. Description of improvement: J .00F I' 1 LC 3.Owner(s) name and address: m K H PE L_ rs r 9 i ES Interest in property: FEE SIMPLE Name and address of fee simple titleholder 4. Contractor's name address and phone number. EARL W. JOHNSTON ROOFING, INC. W 5721 DEEY STREET, HOLLYWOOD, FLORIDA 33023 954 -989 -7794 5. Surety: (Payment bond required by owner from contractor, if any) Name, address and phone number. Amount of bond $ STATE OP 6. Lender's name and address: /HENRY 7. Persons within the State of Florida designated by Owner upon whcfekiNfilkiig Section 713.13(1)(a)7., Florida Statutes, Name, address and phone number. 8. In addition to himself, Owners designates the following person(s) t 713.13(1)(b), Florida Statutes. Name, address and phone number 9. Expiration date of this Notice of Commencement (the expiration date is 1 year from the date of recording unless a different date is specified) WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13. FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. Signature(s) of Owners or Owners ' Authorized Officer /Director /Partner /Manager By i By Print Name JDI,► cJ&&, A S+r-ev1,C/ Print Name Title /Office 0 c.) K'e r- tj Title/Office STATE OF FLORIDA COUNTY OF MIAMI -DADE — ``vt � t The foregoin instru nt was acknowled ed before me this 1 -.5 day of 3 NE R.W ndividually, or ❑ as for ❑ Personally known, or ❑ produced the following type of identificatio Signature of Notary Public: Print Name: (SEAL) VERIFICATION PURSUANT TO SECTION 92.525. FLORIDA STATUTES Under penalties of perjury, I declare that I have read the foregoing and that the facts stated in it are true, to the best of my knowledge and belief. 201 / MEG A. ROMEO MY COMMISSION # DD 788767 EXPIRES: June 22, 2012 F�• oce. Bonded Tin Budget Notary Services FOF Signature(s) of Owne ) or Owner(s)'s Authorized Officer /Director /Partner /Manager who signed above: By By CERTIFICATE OF LIABILITY INSURANCE OP ID: TO DATE (MMIDD/YYYY) 05/27/11 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER, AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED, the policy(ies) must be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER J.W. Edens & Company Commercial Ins of Brevard, Inc 325 Fifth Avenue, Suite 108 Indialantic, FL 32903 Theresa C. O'Brien 321 -725 -7000 321- 725 -7856 CONTACT NAME: PHONE (A/C. No. Ext): E -MAIL ADDRESS: FAX (A/C, No): PRODUCER EARJ001 CUSTOMER ID #: INSURER(S) AFFORDING COVERAGE NAIC # INSURED Earl W. Johnston Roofing Inc. 5721 Dewey Street Hollywood, FL 33023 -1917 INSURERA : Canal Indemnity Company INSURER B : Southern Eagle Ins. Co. 10151 INSURER C : INSURER D : INSURER E : INSURER F : • R: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED .0 INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRA, JR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR LTR TYPE OF INSURANCE ADDL MSR SUER WVD POLICY NUMBER (MMIDD/YYYY) 07/01/10 (MMIDD/YYYY) 07/01/11 LIMITS EACH OCCURRENCE $ 1,000,000 A GENERAL LIABILITY COMMERCIAL GENERAL LIABILITY OCCUR GL100120 X pREMISES Ea ocaurence) $ 50,000 CLAIMS -MADE X MED EXP (Any one person) $ 5,000 PERSONAL & ADV INJURY $ 1,000,000 GENERAL AGGREGATE $ 2,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: PRODUCTS - COMP /OP AGG $ 1,000,000 X POLICY .IF O- LOC $ AUTOMOBILE LIABILITY ANY AUTO ALL OWNED AUTOS SCHEDULED AUTOS HIRED AUTOS NON -OWNED AUTOS COMBINED SINGLE LIMIT (Ea accident) $ BODILY INJURY (Per person) $ BODILY INJURY (Per accident) $ PROPERTY DAMAGE (Per accident) $ _ $ $ UMBRELLA LIAB EXCESS LIAB OCCUR CLAIMS -MADE EACH OCCURRENCE $ AGGREGATE $ DEDUCTIBLE RETENTION $ $ _ $ B WORKERS COMPENSATION AND EMPLOYERS' LIABILITY ANY PROPRIETOR/PARTNER /EXECUTIVE OFFICER/MEMBER EXCLUDED? (Mandatory In NH) If yes, describe under DESCRIPTION OF OPERATIONS Y / N N / A 2011- 09117 -000 06/01/11 06/01/12 X WC STATU- OTH- TORY LIMA fS ER E.L. EACH ACCIDENT $ 1,000,000 E.L. DISEASE - EA EMPLOYEE $ 1,000,000 below E.L. DISEASE - POLICY LIMIT $ 1,000,000 DESCRIPTION OF OPERATIONS / LOCATIONS / VEHICLES (Attach ACORD 101, Additional Remarks Schedule U more space is required) VLI\ 11I IVfi 11. 1 I VL.LILI\ MIAMISH Miami Shores Building & Zoning Department Margarita 10050 N.E. 2nd Avenue Miami Shores, FL 33138 I • ••----- "-• --- SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE Theresa C. O'Brien "' ell f ACORD 25 (2009/09) CC)'1 lf88- Llllll9 A1. [!RU NIJRrIJ RfiI IVIY. fill Ilan IL3 Icicl vc .. The ACORD name and logo are registered marks of ACORD d4, ui; ?s4Pertte.t"<G..i9Irn,":0,,, U:.N IT1,1.17 = = IL-.6 �'e�__11 Y—I r 115 S. Andrews Ave., Rm. A -100, Ft. Lauderdale, FL 33301 -1895 — 954 - 831 -4000 VALID OCTOBER 1, 2010 THROUGH SEPTEMBER 30, 2011 DBA: Business Name: EARL W JOHNSTON ROOFING INC Owner Name: E W JOHNSTON Business Location: 5721 DEWEY ST HOLLYWOOD Business Phone: 989 -7794 Rooms Seats Number of Machines• Employees 10 Receipt #:185 -313 Business Type :ROOFING /SHEET METAL CONT CTO: (ROOFING CONTR) Business Opened:12 /31/1986 State /County /Cert/Reg:86448 3RX Exemption Code :NONEXEMPT For Vending Business Only Machines Professionals I 27 nnl CITY OF HOLLYWOOD LOCAL BUSINESS TAX RECEIPT Collection Cost 0.00 PRINT DATE: 9/20/10 THIS IS YOUR LOCAL BUSINESS TAX RECEIPT. PLEASE DETACH AND POST IN A CONSPICUOUS PLACE AT THE BUSINESS LOCATION. PLEASE DO NOT REMIT ANY PAYMENT THIS IS NOT A BILL. Business Name: Business Location: Business Class: Tax Basis: Receipt Number: Receipt Year: Expiration Date: JOHNSTON EARL W ROOFING INC 5719 DEWEY ST CONTRACTOR /ROOFING 5 - 25 WORKERS 11 00021533 10/01/10 09/30/11 NEW CHARGES: (Itemized Below) Base Fee Additional Charges: 316.00 316.00 TOTAL NEW CHARGES: Penalty Amount: Previous Balance Due: TOTAL AMOUNT PAID: 316.00 .00 .00 316.00 Comments: PURSUANT TO STATE LAW, THE LOCAL BUSINESS TAX IS LEVIED ON THE PRIVILEGE OF DOING BUSINESS WITHIN A CITY'S LIMITS, AND IS NON- REGULATORY IN NATURE. ISSUANCE OF A 'LOCAL BUSINESS TAX RECEIPT BY THE CITY OF HOLLYWOOD DOES NOT vending Type Tax Amount Transfer Fee NSF Fee Penalty Prior Years 27.00 0.00' 0.00 0.00 0.00'. I 27 nnl CITY OF HOLLYWOOD LOCAL BUSINESS TAX RECEIPT Collection Cost 0.00 PRINT DATE: 9/20/10 THIS IS YOUR LOCAL BUSINESS TAX RECEIPT. PLEASE DETACH AND POST IN A CONSPICUOUS PLACE AT THE BUSINESS LOCATION. PLEASE DO NOT REMIT ANY PAYMENT THIS IS NOT A BILL. Business Name: Business Location: Business Class: Tax Basis: Receipt Number: Receipt Year: Expiration Date: JOHNSTON EARL W ROOFING INC 5719 DEWEY ST CONTRACTOR /ROOFING 5 - 25 WORKERS 11 00021533 10/01/10 09/30/11 NEW CHARGES: (Itemized Below) Base Fee Additional Charges: 316.00 316.00 TOTAL NEW CHARGES: Penalty Amount: Previous Balance Due: TOTAL AMOUNT PAID: 316.00 .00 .00 316.00 Comments: PURSUANT TO STATE LAW, THE LOCAL BUSINESS TAX IS LEVIED ON THE PRIVILEGE OF DOING BUSINESS WITHIN A CITY'S LIMITS, AND IS NON- REGULATORY IN NATURE. ISSUANCE OF A 'LOCAL BUSINESS TAX RECEIPT BY THE CITY OF HOLLYWOOD DOES NOT SECTION 1524 ®11 HIGH VELOCITY HURRICANE ZONES REQUIRED OWNERS NOTIFICATION FOR ROOF#10 CONSIDERATIONS ' Lam►'""' 1524.1 As it pertains to this section, it is the responsibility of the roofing contractor to provide the owner with the required roofing permit, and to explain to the owner the content of this section... The provisions of Chapter 15 of the Florida Building Code, Building govem the minimum requirements and standards of the industry for roofing system installations. Additionally, the following items should be addressed as part of the agreement between the owner and the contractor. The owner's initial in the adjacent box indicates that the item has been explained. otit. S 1. Aesthetics Workmanship: The workmanship provisions of Chapter 15 (High Velocity Hurricane Zone) are for the purpose of providing that the roofing system meets the wind resistance and water intrusion performance standards. Aesthetics (appearance) issues are not a consideration with respect to workmanship provisions. Aesthetic issues such as color or architectural appearance, that are not part of a zoning code, should be addressed as part of the agreement between the owner and the contractor. 0" l, jj.S 2. Renailing Wood Decks: When replacing roofing, the existing wood roof deck may have to be renailed in accordance with the current provisions of Chapter 16 (High Velocity Hurricane Zones) of the Florida Building Code. (The roof deck is usually concealed prior to removing the existing roof system). S 3. Common Roofs: Common -roofs -are- those - which - -have no visible delineation--between neighboring units (i.e. townhouses, condominiums, etc.). In buildings . with common roofs, the roofing contractor and/or owner should notify the occupants of adjacent units of roofing work to be performed. MS 4. Exposed Ceilings: Exposed, open beam ceilings are where the underside of the roof decking can be viewed from below. The owner may wish to maintain the architectural appearance; therefore, roofing nail penetrations of the underside of the decking may not be acceptable. The Florida Building Code prAov11idcces the option of maintaining this appearance. 445 5. Ponding Water: The current roof system and/or deck of the building may not drain well and may cause water to pond (accumulate) in low -lying areas of the roof. Ponding can be an indication of structural distress and may require the review of a professional structural engineer. Ponding may shorten the life expectancy and performance of the new roofing system. Ponding conditions may not be evident until the original roofing system is removed. Ponding conditions should be corrected. 6.Ov overloaded if overflow accordance S 7. V interior of the reduced. It m the roof. (wall outlets): It is required that rainwater flows off so that the roof is not ater. Perimeter /edge walls or other roof extensions may block this discharge ts) are not provided. It may be necessary to install overflow scuppers in Code, Plumbing. ctures should have some ability to vent natural airflow through the e building itself). The existing amount of attic ventilation shall not be to consider additional venting which can result in extending the service life of Owner's/Agenrs Signature �c_ A me 101 11,■tk Property Address Date Mia r ores Village BY DATE ® ZONING DEPT _ BLDG DEPT ` z ` ? SUBJECT TO COMPUANCE WITH ALL FEDERAL STATE AND COUNTY RULES AND REGULATIONS �� t Sri S * a9e i'€dy Dejwitateat 10050 NE 2nd Ave * Miami Shores, FI 33138 Phone 305-795-2204; Fax 305-756-8972 OWNERS'S AFFIDAVIT OF EXEMPTION ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR EXISTING SITE - BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES PERSUANT TO SECTION 553.844 F.S. To: Miami Shores Village Building Department 10050 NE 2nd Ave Miami Shores, FI 33138 Re: Owner's Name: Fyn Property Address: 22 N E Roofing Permit Number: MtC->i'1I`h1ku ork2 Date: (R (I (, Dear Building Official: 1 M I C4 ( certify that I am not required to retrofit the roof to wall connections of my building because: ❑ The just valuation for the structure for purpose of ad valorem taxation is less than $300,000.00. Please attach proof of ad valorem taxation. ❑ The building was constructed in compliance with the provisions of the Florida Building Code (FBC) or with the provisions of 1994 edition of the South Florida Building Code (1994 SFBC) Signature A' bN G- Print Name State of Florida County of Dade The undersigned, being the first duly sworn, deposes and says that he /she is the contractor for the above property mentioned. Sworn to and subscribed before me this Notary Public, Sate of Florida at Large day of JLi4'ie,iOi( MEG A. ROMEO * MY COMMISSION # DD 788767 EXPIRES: June 22, 2012 cr9 %Fnc v, O� Bonded Tim Budget Notary Services * When the just valuation of the structure for purpose of ad valorem taxation is • to or more than $300,000.00, and the building was not constructed with FBC nor a 1994 SFBC. Then you must provide a building application from a G �- • I Contractor for the Roof to Wall connection Hurricane Mitigation. My Home n am;c % tie qov.,. Show Me: Property Information -Text Search By: Select Item Address Search 'Enter the address and click "LOCATE". Use the Tab key to switch between fields or click using the mouse. House 229 Number. ' Direction: NE Street Name: 101 Street Type: ST Unit (opt): Zip Code (opt): 6/24/2011 Go to property map Property Appraiser Tax Estimator EProoerty Appraiser Tax Comparison Portabilitv S.O.H. Calculator Summary Details: Print friendly version Folio No.: 11- 3206-013 -4790 Property: 229 NE 101 ST Mailing Address: MICHAEL D STRONG 229 NE 101 ST MIAMI SHORES FL 33138 -2422 Proeerty Information: Primary Zone: 1000 SINGLE FAMILY RESIDENCE CLUC: 0001 RESIDENTIAL - SINGLE FAMILY BedsBaths: 2/2 Floors: 1 Living Units: 1 AdJ Sq Footage: 2,019 Lot Size: 11,500 SQ FT Year Built 1938 Legal Description: MIAMI SHORES SEC 1 AMD PB 10 -70 LOT 15 816 BLK 35 LOT SIZE 100.000 X 115 OR 20644 -0768 08 2002 4 COC 25648 -4131 05 2007 5 OR 25648 -4131 0507 01 Assessment Information: Year: 2010 2009 Land Value: $1797.0 $198,144 Building Value: 159,092 $170,209 Market Value: $62 $366,353 Assessed Value: $293,167 $285,460 Exemctlan Information: Year: 2010 2009 Homestead: $25,000 $25,000 2nd Homestead: YES YES Taxable Value Information: Year: 2010 2009 Taxing Authority: Applied Exemption/ Taxable Value: Applied Exemption/ Taxable Value: Regional: $50,000 /$243,167 $50,000/$235,460 County: $50,000/$243,167 $50,000/$235,460 City: $ 50,000/$243,167 $50,000 /$235,460 School Board: $25,000/$268,167 $25,0004260,460 Sale Information: Sale Date: 5/2007 Sale Amount $0 Sale 0/R: 25648 -4131 Sales Qualification Description: Sales which are disqualified as a result of examination of the deed View Additional Sales Additional Information: lick here to see more information for his orooertv Community Development District Community Redevelopment Area Empowerment Zone Enterprise Zone Zoning Land Use Urban Development Boundary Zoning Non -Ad Valorem Assessments Environmental Considerations. Questions and Comments webmaster a(miamidade.gov Property Appraiser Home Pape Property Information Online Help Property Information Home Page Florida Building Code Edition 2007 High Velocity Hurricane Zone Uniform Permit Application Form ' INSTRUCTION PAGE COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING PERMIT APPLICATION FORM AND ATTACH THE RE- QUIRED DOCUMENTS AS NOTED BELOW: Roof System Required Sections of the Permit Application Form Attachments Required See List Below Low Slope ApplitIon A,B,C 1,2,3,4,5,6,7 A,B,C 4,5,6,7 Prescriptive BUR -RAS 150 Asphaltic Shingles A,B,D 1,2,4,5,6,7 CConcre> or CI 'T'. 1.2.3.4.5,6,7 Metal Roofs A,B,D 1,2,3,4,5,6,7 Wood Shingles and Shakes A,B,D 1,2,4,5,6,7 Other As Applicable 1,2,3,4,5,6,7 ATTACHMENTS REQUIRED: 1. Fire Directory Listing Page 2. From Notice of Acceptance: Front Page Specific System Description Specific System Limitations General Limitations Applicable Detail Drawings 3. Design Calculations per Chapt4r 16, or If Applicable, RAS 127 or RAS 128 4. Other Component Notice of Acgeptances 5. Municipal Permit Application 6. Owners Notification for Roofing Considerations (Re- Roofing Only) 7. Any Required Roof TestinglCalculation Documentation Florida Building Code Edition 2007 High Velocity Hurricane Zone Uniform Permit Application Fomi Master Permit No. Contractor's Name Job Address Section A (General Information) Process No. Vf . a114i ii)n tw®ci n. 221 NE IO 1 WO- X. Low Slope ❑ Asphaltic Shingles ROOF CATEGORY ❑ Mechanically Fastened Tile ❑ Metal Panel/Shingles ❑ Prescriptive BUR -RAS 150 Mortar/ dhe a Set Tile ❑ Wood Shingles/Shakes ROOF TYPE ❑ New Roof Re- Roofing O Recovering ❑ Repair ❑ Maintenance ROOF SYSTEM INFORMATION Low Slope Roof Area (SF) Steep Sloped Roof Area (SF) Total (SF) ' oo Section B (Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. ■■••■■ ■■ ■ ■ ■■ ■■■ ■■ ■ ■••■■■■•F-= :::•;<i ■i Florida Building Code Edition 2007 High Velocity Hurricane Zone Uniform Permit Application Form Section C (Low Sloped Roof System) Fill in Specific Roof Assembly Components and Identify Manufacturer (If a component is not used, identify as "NA ") System Manufacturer: NOA No.: p°i 2-.( . ° og Design Wind Pressures, From RAS 128 or Calculations: , t Pmax1:4t'2- Pmax2: 9 Z Pmax3: I2`t Max. Design Pre ure, rom the Specific NOA System: Type: WO OlO \ Gauge/Thickness: ci Slope: Fr /at o. o ' ly(s): nchor/Base Sheet Fastener/Bonding Material: I I'sulation Base Layer: {ase Insulation Siz ease Insulation r 11 op Insulation Size and Thickness: ,op Insulation Fastener /Bonding Material: Base Sheet(s) & No. of 4;71-0-0 5.1(1 Base Sheet ` �Fastener /Bon Ina pteria� �r ,�q 4 �‘ tivs moti s r Xi N cli and Thickness: Bonding Material: p Insulation Layer: Ply Sheet(s) & No. of Ply s): pi/ (7--) Ply Sheet Fastener /Bonding Material,: M a t e rial: alt - 14-t, t- ON n 1 i l- C Jts ,+y To Ply: ic / r t Top Ply Fastener /Bonding Material: f-1\.) Surfacing: f �d Fastener Spacing for Anchor /Base Sheet Attachment Field: 9 .0c @ Lap, # Rows /� @ " oc Perimeter: to " oc @ Lap, # Rows�l �� @ oc Corner: ( " oc @ Lap, # Rows{ @Co " oc Number of Faste ers Per Insulation Board Field 14,4 Corner Illustrate Components Noted and Details as Applicable: Woodblocking, Gutter, Edge Termination, Stripping, Flashing, Continuous Cleat, Cant Strip, Base Flashing, Counter- Flashing, Coping, Etc. Indicate: Mean Roof Height, Parapet Height, Height of Base Flashing, Component Material, Material Thickness, Fastener Type, Fastener Spacing or Submit Manufacturers Details that Comply with RAS 111 and Chapter 16. Parapet Height Mean Roof Height Florida Building Code Edition 2007 High Velocity Hurricane Zone Uniform Permit Application Form Section D (Steep Sloped Roof System) Roof System Manufacturer: ei'r° Notice of Acceptance Number: ®(Q '° 0 %I i) a tJ Minimum Design Wind Pressures, If A plicable (From RAS 127 or Calculations): Pmax1: 45 Pmax2:" Pmax3: j, t (0 ; Maximum Design Pressure (From the NOA Specific System): IOU' .(i' 1 Method of Tile Attachment: P01,1 ADAM 0171.,--q JO WV Pa+ UN Roof Slope: 12 eck Type: Sloped System Description WD Type Underlayment: Insulation: Fire Barrier: 30 4Un/vi Ridge � Vn Ventilation? Kit Mean Roof Height: M Fastener Type & Spacing: dhesive Type: ( rt i p; I 1'J f-bbT %3 jpif1 ri' ype Cap Sheet: 1 Ql0 'l -1'°12-AYVl oofing Covering: Type & Size Drip dge: I &A U u Florida Building Code Edition 2007 High Velocity Hurricane Zone Uniform Permit Application Form Section E (Tile Calculations) For Moment -based tile systems, choose either Method 1 or 2. Compared the values for Mr with the values from M. If the M1 values are greater than or equal to the Mr values for each area of the roof, then the tile attachment method is acceptable. �����.-- Method 1 "Moment -Based Tile Calculations Per R AS 127" (P1:_1J x A • 22.9 = t3nn 5 ) - Mg = Mr1 aIhe NOA Mr P.10 1 L (P2:1,__8_ x % .189 = 1I )-Mg =M2 } _.,:' 1 NOA Mr >tot k d ', D C9 (p3:111_, x .14361 =3'I ) -Mg: 1 ; = Mr3 :� .utmo NOA Mr 81p. 01 _ O Method 2 "Simplified Tile Calculations Per Table Required Moment of Resistance (Mr) From Table Below 30 aN NOA Mr Tte. to 1 Mr Required Moment Resistance* Mean Roof Height Roof Slope 15' 20' 25' 30' 40' 2:12 34.4 36.5 38.2 39.7 42.2 312 32.2 34.4 36.0 37.4 39.8 4:12 32.2 33.8 35.1 37.3 5:12 28.4 30.1 31.6 32.8 34.9 6:12 26.4 28.0 29.4 30.5 32.4 7:12 24.4 25.9 27.1 28.2 30.0 *Must be used in conjunction with a list of moment -based tile systems endorsed by the Broward County Board of Rules and Appeals. For Uplift-based tile systems use Method 3. Compared the values for P with the values for Fr. If the P values are greater than or equal to the Fr values for each area of the roof, then the tile attachment method is acceptable. Method 3 "Uplift-Based Tile Calculations Per RAS 127" (P1:_ xl:_= _xw:= _)- W:_xcos 6: =Fr1: NOAF1 (P2:_ xl: ___xw:_ W:_xcos 0: =F2: NOAF1 _)- (P3:_ xI: _xw:_ _)- W:_xcos 6: =F2: NOAF1 Where to Obtain Information Description Symbol Where to find Design Pressure P1 or P2 or P3 RAS 127 Table 1 or by an engineering analysis prepared by PE based on ASCE 7 Mean Roof Height H Job Site Roof Slope 0 Job Site Aerodynamic Multiplier d NOA Restoring Moment due to Gravity Ma NOA Attachment Resistance M, NOA Required Moment Resistance M Calculated Minimum Attachment Resistance F1 NOA - Required Uplift Resistance F, Calculated �- Average Tile Weight W NOA Tile Dimensions I= length w = width NOA All calculations must be submitted to the Building Official at the time of permit application. • iV► I oAar;. BUILDING CODE COMPLIANCE OFFICE (BCCO) PRODUCT CONTROL DIVISION NOTICE OF ACCEPTANCE (NOA) GAF Material Corporation. 1361 Alps Road Wayne, NJ 07470 MIAMI -DADE COUNTY, FLORIDA METRO -DADE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 MIAMI, FLORIDA 33130 -1563 (305) 375 -290I FAX (305) 375 -2908 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by the BCCO and accepted by the Building Code and Product Review Committee to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Division that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code and the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: GAF Conventional Built-Up Roof System for Wood Decks. LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews and revises NOA No. 03- 0501.05 and consists of pages 1 throygh 19. The submitted documentation was reviewed by Jorge L. Acebo. MIAMI DADE COUNTY APPROVED NOA No.: 07- 1219.09 Expiration Date: 11/04/13 Approval Date: 03/20/08 Pagel of 19, ROOFING SYSTEM APPROVAL Category: Sub - Category: Deck Tyne: Maximum Design Pressure Roofing BUR Wood -75 psf TRADE NAMES OF PRODUCTS MANUFACTURED"OR LABELED BY APPLICANT: TABLE 1 Product Dimensions Leak BusterTM MatrixTM 3, 5, 55 gallons 307 Premium Asphalt Primer GAF Mineral ShieldTM 60 & 100 lb. bags Granules Leak BusterTM MatrixTM 5 gallons 305 Fibered Asphalt Emulsion Leak BusterTM MatrixTM 303 Premium Fibered Aluminum Roof Coating LeakBusterTM MatrixTM • 322 Elastomeric Roof Coating LeakBusterTM MatrixTM Select Asphalt Emulsion Fibered 306 Leak BusterTM MatrixTM 204 Wet/Dry Roof Cement RUBEROID® Modified Bitumen Flashing Cement LeakBusterTM MatrixTM 201 Premium SBS Flashing Cement GAFGLAS® 1175 Test Specification ASTM D41 Product Description Asphalt concrete primer used to promote adhesion of asphalt in built -up roofing. ASTM D 1863 Granules for surfacing of exposed asphalt, cold process cement or emulsion. GAF Mineral ShieldTM Granules shall be used for flashing applications only. ASTM 1227 Surface coating for smooth surfaced roofs. 1, 5 gallons ASTM D 2824 Fibered aluminum coating. 55 gallons 55 gallons 1, 5 gallons 5 gallons 5 gallons Elastomeric roof coating. Asphalt emulsion fibered. ASTM D-4586 Refined asphalt blended with a mineral ASTM D -3409 stabilizer and fibers. Permits adhesion to wet and dry surfaces. ASTM D 4586 Fiber reinforced, polymer modified Flashing cement ASTM D 4586 Asphalt flashing Cement 39.37" (1 meter) ASTM D 4601 Asphalt impregnated and coated glass mat wide base sheet. NOA No.: 07- 1219.09 Expiration Date: 11/04/13 Approval Date: 03/20/08 Page 2 of 19 Product GAFGLAS® #80 ULTIMATM Base Sheet GAFGLAS® Flex PIyTM 6 GAFGLAS® illy 4 GAFGLAS® Mineral Surfaced Cap Sheet GAFGLAS® EnergyCapTM Mineral Surfaced Cap Sheet GAFGLAS® STRATAVENT® EliminatorTM Perforated GAFGLAS® Flashing GAFGLAS® STRATAVENT® EliminatorTM Nailable .RUBEROID® SBS Heat We1dTM Smooth RUBEROID® SBS Heat- WeIdTM Granule RUBEROID SBS Heat We1dTM 170 FR RUBEROID® SBS Heat We1dTM PLUS RUBEROID® SBS Heat- We1dTM PLUS FR. RUBEROID® SBS Heat- WeIdTM 25 RUBEROID® Modified Base Sheet MANMADE COUNTY APPROVED Dimensions 39.37" (1 meter) wide 39.37" (1 meter) wide 3937" (1 meter) wide 39.37" (1 meter) wide 39:37" (1 meter) wide 39.37" (1 meter) wide Various 39.37" (1 meter) wide 1 meter (39.37 ") wide 1 meter (39.37") • wide 1 meter (39.37") wide 1 meter (3937") wide 1 meter (39.37 ") wide 1 meter (39.37 ") wide 39.37" (1 meter) wide Test Specification ASTM D4601 ASTM D 2178 ASTM D2178 ASTM D 3909 ASTM D 3909 ASTM D 4897 D 3672 ASTM D 4897 D 3672 • ASTM D -6164 ASTM D -6164 ASTM D -6164 ASTM D -6164 ASTM D -6164 ASTM D -6164 ASTM D4601, Type II, UL Type G2 BUR Product • Description Asphalt impregnated and coated, fiberglass base sheet Type VI asphalt impregnated glass felt with asphalt coating. Type IV asphalt impregnated glass felt with asphalt coating. Asphalt coated, glass fiber mat cap sheet surfaced with mineral granules. Asphalt coated, glass fiber mat cap sheet surfaced with mineral granules with factory applied layer of TOPCOAT®EnergyCoteTM. Fiberglass base sheet impregnated and coated on both sides with asphalt. Surfaced on the bottom side with mineral granules embedded in asphaltic coating with factory perforations. Asphalt coated glass fiber mat flashing sheet available in three sizes. Fiberglass base sheet impregnated and coated on both sides with asphalt. Surfaced on the bottom side with mineral granules embedded in asphaltic coating. Non -Woven Polyester mat coated with polymer - modified asphalt and smooth surfaced. Non -Woven Polyester mat coated with polymer modified asphalt and surfaced with mineral granules. Non -Woven Polyester mat coated with fire retardant polymer modified asphalt and surfaced with mineral granules. Non -Woven Polyester mat coated with . polymer modified asphalt and surfaced with mineral granules. Non -Woven Polyester mat coated with fire retardant polymer modified asphalt and surfaced with mineral granules. Non -Woven Polyester mat coated with polymer- modified asphalt and smooth surfaced. Premium glass fiber reinforced SBS modified base sheet NOA No.: 07- 1219.09 Expiration Date: 11/04/13 Approval Date: 03/20/08 Page 3 of 19 Product RUBEROID® 20 RUBEROIDa) Mop Granule RUBEROID® Mop Plus (Granule) RUBEROID® MOP Smooth RUBEROID® MOP 170FR RUBEROID® MOP FR RUBEROID ® TORCH Smooth RUBEROID® TORCH Granule RUBEROID® TORCH PLUS (Granule) RUBEROID TORCH FR RUBEROID® 170FR TORCH RUBEROID® 30 RUBEROID® 30 FR RUBEROID® ULTRACLAD® RUBEROID® Dual FR Vent Stacks (metal and plastic) MIAMFOAD_ COUNTY APPROVED Dimensions 3937" (l meter) wide 39.37" (1 meter) wide 39.37" (1 meter) wide 39.37" (l meter) wide 3937" (1 meter) wide 39.37" (1 meter) wide 39.37" (1 meter) wide 3937" (1 meter) wide 39.37" (1 meter) wide 39.37" (l meter) wide 3937" (l meter) Wide 39.37" (1 meter) wide 39.37" (l meter) wide 39.37" (1 meter) wide 3937" (1 meter) Wide Test Specification ASTM D 6163 ASTM D 5147 ASTM D 6222 ASTM D 5147 ASTM D 6222 ASTM D 5147 ASTM D 6164 ASTM D 5147 ASTM D 6164 ASTM D 5147 ASTM D 6164 ASTM D 5147 ASTM D 5147 ASTM D 5147 .ASTM D 6222 ASTM D 5147 ASTM D 6222 ASTM D 5147 ASTM D 6222 ASTM D 5147 ASTM.D 6163 ASTM D 5147 ASTM D 6163 ASTM D 5147 ASTM D 6298 ASTM D 5147 ASTM D 6164 ASTM D 5147 TAS 100(A) ASTM D 1929 ASTM D 635 Product Description SBS modified asphalt base sheet and interply sheet reinforce with a glass fiber mat. Non -woven polyester mat coated with polymer modified asphalt and surfaced with mineral granules. Non -woven polyester mat coated with polymer modified asphalt and surfaced with mineral granules. Non -woven polyester mat coated with polymer- modified asphalt and smooth surfaced. Non -Woven polyester mat coated with fire retardant polymer modified asphalt and surfaced with mineral granules. Non -Woven polyester mat coated with fire retardant polymer modified asphalt and surfaced with mineral granule's. Heavy duty, polyester reinforced, asphalt modified bitumen membrane, smooth surface. Asphalt impregnated, coated felt, surfaced with mineral granule. Heavy duty, polyester reinforced, asphalt modified bitumen membrane, granule surface. Heavy duty, polyester reinforced, coated with fire retardant asphalt modified bitumen membrane, granule surface. Heavy duty, polyester reinforced, coated with fire retardant asphalt modified bitumen membrane, granule surface. Non -woven fiberglass mat coated with polymer modified asphalt and surfaced with mineral granules. Non -woven fiberglass mat coated with fire retardant polymer modified asphalt and surfaced with mineral granules. Woven fiberglass mat coated with Polymer modified asphalt and surfaced with aluminum, copper or stainless steel foil. Non -woven polyester and fiberglass mat coated with file retardant, polymer modified asphalt and surfaced with mineral granules. One way valve vent used to relieve bulup pressure within the roof system. GAF Vent Stacks are available in metal or plastic. NOA No.: 07- 1219.09 Expiration Date: 11/04/13 Approval Date: 03/20/08 Page 4 of 19 Product Leak BusterTM MatrixTM 302 Non Fibered Aluminum Roof Coating GAF Built -Up Roofing Asphalt - RUBEROID® MOD Asphalt, Asphalt L & Asphalt P Leak BusterTM MatrixTM 602 Leak BusterTM MatrixTM 715 LeakBusterTM MatrixTM 531 WeatherCoteTM SeamCoteTM FireOutTM VersaShield® VersaShield® FB-1S VersaShield® FB -2S TOPCOAT® FireShield® MB Leak BusterTM MatrixTM 201 SBS Flashing Cement Leak BusterTM MatrixTM 102 SBS Adhesive Leak BusterTM MatrixTM 202 SBS Flashing Cement Leak BusterTM MatrixTM 203 Plastic Roof Cement Leak BusterTM MatrixTM 103 Cold Process Adhesive M I•DADE • UN71r APPROVED Dimensions 5 gallons 1001b. cartons, bulk 60 Ib. kegs 5 gallons 5 gallons 2 gallons 2, 5 gallons 5, 55 gallons 350 sq ft. roll 350 sq ft. roll 350sg ft. roll 5, 55 gallons 5 gallons 5 gallons 5 gallons 5 gallons 5 gallons Test Specification Product Description ASTM D2824, Non- fibered aluminum pigmented, asphalt Type 1 roof coating. ASTM D312, - TypesI,II,III and IV proprietary ASTM D -412 ASTM D -21 -96 ASTM D1475 ASTM E -1644 ASTM D3019 ASTM D3019 ASTM D4586 ASTM D4586 ASTM D3019 Interply mopping and surfacing asphalt. SEBS modified asphalt. Surface coating for smooth surfaced and mineral surfaced roofs. Surface coating for smooth surfaced and mineral surfaced roofs. Surface coating for smooth surfaced and mineral surfaced roofs. Elastomeric roofing membrane. Low VOC, fire barrier coating. Non - Asphaltic Fiberglass -Based Underlayment. Non - Asphaltic Fiberglass -Based Underlayment. Non - Asphaltic Fiberglass -Based Underlayment. Elastomeric roofing membrane Cold Applied Modified SEBS Asphalt Adhesive — Flashing Grade. Cold Applied Modified SEBS Asphalt Adhesive. Cold Applied Modified SEBS Asphalt Adhesive — Flashing Grade. Standard Plastic Asphalt Roofing Cement Cold Applied Asphalt Adhesive. NOA No.: 07- 1219.09 Expiration Date: 11/04/13 Approval Date: 03/20/08 Page 5 of 19 Product Dimensions Leak BusterTM MatrixTM 5 gallons 303 Fibered Aluminum Roof Coating Leak BusterTM MatrixTM 5 gallons 304 Non Fibered Aluminum Roof Coating APPROVED INSULATIONS: Product Name. EnergyGuardTM RA, RN Composite A & N EnergyGuardTM Fiberboard EnergyGuardTM Permalite EnergyGuardTM GAFCANTTM EnergyGuardTM Permalite Recover Board EnergyGuardTM Tapered Edge Strip EnergyGuardTM Perlite EnergyGuardTM High Density Fiberboard EnergyGuardTM Composite EnergyGuardTM Composite RA Wood Fiber High Density Wood Fiberboard Perlite Insulation Dens Deck', Dens Deck® Prime, Dens Deck® Dura GuardTM Structodek SecurockTM Test Specification ASTM D 2824 Product Description Fibered aluminum coating. ASTM D2824, Non - fibered aluminum pigmented, asphalt Type I - roofcoating. Table 2 Product Description: Polyisocyanurate foam insulation Polyisocyanurate foam insulation with high density fiberboard or Permalite perlite insulation. Fiberboard insulation. Perlite insulation board. Cut perlite board Perlite recover board Tapered perlite board Perlite insulation board High density wood fiberboard insulation. Polyisocyanurate/wood fiberboard composite Polyisocyanurate /wood fiberboard composite Wood fiber insulation board Wood fiber insulation board Perlite insulation board Water resistant gypsum board Wood fiber insulation board Fiber reinforced roof board Manufacturer (With Current NOA) BMCA • ' GAF Materials Corp. GAF Materials Corp. GAF Materials Corp. GAF Materials Corp. GAF Materials Corp. GAF Materials Corp. GAF Materials Corp. GAF Materials Corp. BMCA BMCA generic generic generic G -P Gypsum Corp Knight Celotex USG Corporation NOA No.: 07- 1219.09 Expiration Date: 11/04/13 Approval Date: 03/20/08 Page 6 of 19 APPROVED FASTENERS: Fastener Product Number Name 1. Drill -TecTM #12 Standard, #14 and #15 extra Heavy Duty Fastener , Heavy Duty Roofing-Fastener 2. Drill -TecTM ASAP 3. Drill -TecTM #12 or #14 Standard screws with AccuTrac Plate 4. Drill-TecTM Galvalume Plates 5. Drill -TecTM Polypropylene Plates 6. Drill -TecTM AccuTrac Plate EVIDENCE SUBMITTED: Test Aaencv Factory Mutual Research Corp. PRI Asphalt Technologies, Inc. IRT of S. Fl. MJAM 1 DADE COUNTY APPROVED TABLE 3 Product Description Insulation fastener and Base Play fastener for steel, wood & concrete decks. Pre - assembled Drill - TecTM Fasteners and metal and plastic plates. Base sheet fastening assembly. Round Galvalume stress plates. Round polypropylene stress plates. Square Galvalume® coated steel plate. Test Identifier J.I.2B8A4.AM J.I.3B9Q1:AM J.I. ODOA8.AM J.I.ODIA8.AM J.I.0Y9Q5.AM 3029832 GAF - 012 -02 -02 GAF- 020 -02 -01 02 -005 02 -014 Dimensions Various Various Various 3" and 3 %2" 3" and 3 1/2" Manufacturer (With Current NOA) GAF Materials Corp. GAF Materials Corp. GAF Materials Corp. GAF Materials Corp. GAF Materials Corp. 3" Square GAF Materials Corp. Description 4470 4470 4470 4470 -TAS 114 4470 - TAS 114 4470 - TAS 114 Physical Properties ASTM D 4977 TAS 114 TAS 114 . Date 07.02.97 01.08.98 07.09.99 07.29.94 04.01.98 05.11.07 11.06.01 02.01.02 01.18.02 03.22.02 NOA No.: 07- 1219.09 Expiration Date: 11/04/13 Approval Date: 03/20/08 Page 7 of 19 Deck Type 1: Wood, Non - insulated Deck Description: 19/3: or greater plywood or wood plank decks System Type E: Base sheet mechanically fastened. All General and System Limitations shall apply. Fire Barrier: FireOutTM Fire Barrier Coating, VersaShield Non - Asphaltic Fiberglass -Based (optional) Underlayment or SecurockTM. Base sheet: GAFGLAS® #80 ULTIMATM Base Sheet, STRATAVENT® EliminatorTM Nailable, RUBEROID® Modified Base Sheet, RUBEROID® 20, RUBEROID® Heat - Weld"' Smooth or RUBEROID® Heat - WeIdTM 25 base sheet mechanically fastened to deck as described below; Fastening Options:. GAFGLAS® Ply 4, GAFGLAS® Flex PlyTM 6, GAFGLAS® #75 Base Sheet or any of above Base sheets attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" o.c. at the lap staggered and in two rows 12" o.c. in the field. (Maximum Design Pressure —45 psf, See General Limitation #7) GAFGLAS® Ply 4, GAFGLAS® -Flex PIyTM 6, GAFGLAS® #75 Base Sheet or any of above Base sheets attached to deck with Drill -TecTM #12 standard, #14 or # 15 Screws and 3" Drill -Teem steel plate or Drill -TecTM AccuTrac Plates, 12" o.c. in 3 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 12" o.c. in the field of the sheet. (Maximum Design Pressure —45 psf, See General Limitation #7) GAFGLAS® Flex PIyTM 6,9AFGLAS® #75 Base Sheer any of above Base sheets attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" o.c. at the 4" lap staggered and in two rows 9" o.c. in the field. (Maximum Design Pressure —52.5 psf, See General Limitation #7) GAFGLAS® #80ULTIMATM, RUBEROID® 20, RUBEROID®Mop Smooth, base sheet attached to deck with approved 1'A" annular ring shank nails and inverted 3" steel plate at a fastener spacing of 9" o.c. at the 4" lap and in two rows staggered with a fastener spacing of 9" o.c. in the center of the membrane. (Maximum Design Pressure —60 psf, See General Limitation #7) GAFGLAS® #75 Base Sheet or any of above Base sheets attached to deck with Drill-Teem #12 standard, #14 or # 15 Screws and 3" Drill -TecTM steel plate or Drill -TecTM AccuTrac Plates, 12" o.c. in 4 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 9" o.c. in the field of the sheet. (Maximum Design Pressure —60 psf, See General Limitation #7) Any of above Base sheets attached to deck approved annular ring shank nails and:3" inverted Drill -TecTM insulation plates at a fastener spacing of 9" o.c. at the 4" lap staggered in two rows 9" in the field. (Maximum Design Pressure —60 psf, See General Limitation #7) NOA No.: 07- 1219.09 Expiration Date: 11/04/13 Approval Date: 03/20/08 Page 17 of 19 Ply Sheet: Cap Sheet: Surfacing: GAFGLAS® #75 Base Sheet or any of above Base sheets attached to deck with Drill -TecTM #12 standard, #14 or # 15 Screws and 3" Drill -TecTM steel plate or Drill -TecTM AccuTrac Plates, 8" o.c. in 4 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 9" o.c. in the field of the sheet. (Maximum Design Pressure —75 psf, See General Limitation #7j One orjoreplies of GAFGLAS® PL14 #80 ULTIMA, RUBEROID® MOP Smooth or RUBEROID® 20 adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20- 40lbs./sq. - (Optional) One • ly of GAFGLAS® Mineral Surfaced Ca • Shee or GAFGLAS'' EnergyCapTM Mineral Surfaced Cap Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20 -40 lbs./sq. (Optional, required if RUBEROID® MOP Smooth or RUBEROID® 20 is top membrane) Install one of the following: 1. Gravel or slag applied at 400lbs./sq. and 300 Ibs.sq. respectively in a flood coat of approved asphalt at 60 lbs. /sq. or applied in a flood coat of Leak BusterTM MatrixTM 103 Cold Process Adhesive applied at a rate of 3 gal. /sq. 2. GAFGLAS® Mineral Surfaced Cap Sheet, GAFGLAS® Energy Cap Mineral Surfaced Capsheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 Ibs./sq. 3. Leak BusterTM MatrixTM 303 Premium Fibered Aluminum Roof Coating, at 1.5 gal./sq. 4. Leak BusterTM MatrixTM 715 , Leak BusterTM MatrixTM 322, TOPCOAT® MB +, TOPCOAT® Fireshield Elastomeric Roofmg Membrane, applied at 1 to 1.5 gal./sq. S. Leak BusterTM MatrixTM 602 MB Xtra Elastomeric Roofing Membrane, EnergyCote® roof coating applied at 1 to 1.5 galisq. 6. TOPCOAT® Surface Seal, TOPCOAT® Fireshield® SB Solvent based Elastomeric Roofing Membrane applied at lto 1.5 galJsq 7. Advance Green Technologies Photovoltaic Laminate solar energy collector auxiliary roof equipment installed in compliance with manufacturer's specifications and applicable Building Codes. Maximum Design Pressure: See Fastening Above NOA No.: 07- 1219.09 Expiration Date: 11/04/13 Approval Date: 03/20/08 Page 18 of 19 WOOD DECK SYSTEM LIMITATIONS: 1 A slip sheet is required with Ply 4 and Flex PIyTM 6 when used as a mechanically fastened base or anchor sheet. 2. Minimum 'A" Dens DeckTM or %Z" Type X gypsum board is acceptable to be installed directly over the wood deck. GENERAL-LIMITATIONS: 1. Fire classification is not part of this acceptance, refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 Ibs.sq., or mechanically attached using the fastening pattern of the top layer 3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size shall be 4' x 4' maximum. 4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at each sidelap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 12 lbs./sq. Note: Spot attached systems shall be limited to a maximum design pressure of -45 psf. 5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F) value of 275 lbf., as tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field - tested, are below 275 lbf. insulation attachment shall not be acceptable. 6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing, prepared, signed and sealed by a Florida Registered Engineer, Architect, or Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117. 7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred within this NOA, General Limitation #9 will not be applicable.) 8. All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs shall conform with Roofing Application Standard RAS 111 and applicable wind load requirements. 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners and corners). (When this limitation is specifically referred within this NOA, General Limitation #7 will not be applicable.) 10.. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9B-72 of the Florida Administrative Code. END OF THLACCEPTANCE MIAMIIDAOE COUNTY APPROVED NOA No.: 07- 1219.09 Expiration Date: 11/04/13 Approval Date: 03/20/08 Page 19 of 19 .ii z (OOFING SYSTEMS (TGFU)— Continu lyl _. m: 'Poly -Iso' or "Po o Special' with'Poly(oant POIyfoam- +41 til tbs. min. •_ •, : :�:' ; : ±.,.. . .. • .'•; se Cost: One or two appUcations 'GacoRe�t (18.7050', applied at 1" /so/application or three applications. applied 1.1/4 gal /sq / application •32 .dry mils). •facing:'Gacofex UA•6S' Series (various colors), applied 1 gal /sq (12 • mils). : 11C Incline: 1/2 ' ' '' " am:'PolyIso' ot'Poly -iso Special' with'Potyloam 251—or 'Polyfoam 3' 1 In. min. • se Coat: One or two applications 'Gacoflex U0 -7050 , applied at 1 Do/application or lluee applications. applied 1.1/4 gal /sq/application t�l 3t dr/ mils).. rrfacing:'Gacoflex 0A-60-Series (various colors), applied 1 gat/sq (15 y mils). k: HC M lncllne: 2 ,am:'Poly -Iso' or'Poly -Iso Special' with 'Polyfoam 251' or'Potyfoam 33', 1 In, min. lied at 1 al�s (10 d mils ase Coat: 'GacoSil S- 1000', applied 9 q ( dry )• urfacing:'Gacoflex S•1000', applied at 1 gal/sq (10 dry mils). :k: IIC incline: 1 oam:'Polyfoam 251' or't'olyfoam 303'. any thickness- . .urfadng: 'Gacoflex Ure- Shield 7007'. 40 dry mils. ck: HC • Incline: 2.1/2 - oam:'Polyfoam 275". any thickness. - ;ase Coat:'GacoRex A- 6211', 1 -1/2 gal /sq (14 thy mils)_ • ;urfacing: 'Gacoflex A -6200' series (various colors). 1 -1/2 gal /sq (14 :ry'sits). . • iATERIALS CORP 61 ALPS R0, WAYNE 113 07470 :EROID 20' or 'RUBEROID Modified Base Sheet" may be utilized as an ate to Type G2 base sheets in any of the following Classifications. in thick (min) gypsum board or 1/4 in. prick (min) Georgia - Pacific -flecks' overlayrnerst board may be used in any existing noncombustible Classification. When this is done. the resulting roofing system • is •table for use over combustible (15/32 in. min) roof decks. the Joints in ypsum board and overlayment board are offset 6 in. with the joints in the If polyslyrerie'i1 part of the roof system. it must be placed below the syment board. ASPIIALT FELT SYSTEMS WITH IIOT ROOFING ASPHALT e G2 asphalt glass mat base sheet ( "GAFGLAS {i75 Base Sheet") is a !ale alternate for Type GI asphalt glass fiber ply sheet ('GAFGLAS Ply 4' or ;LAS Ply 6-) in the Class A. 8 or C roof systems indicated below. roof deck may first be coveted wills a Type G2 asphalt glass mat base -GAfGLAS Stratavent (vent-Ply) perforated' or GAFGLAS Stratavent,. : -Ply) for nailable decks. Perforated to be mopped and callable to be sonically attached granule side down. an option Type G2 asphalt glass mat base sheet ('GAfGLAS t75 Base Sheet" ,AFGLAS St,ataverst (Yessl•Ply) for nailable decks) may be substituted for halt glass fiber ply sheet l- GAFGLAS Ply 4- or "GAfGLAS Ply 61 as the •base ply in the following systems. :tom ply or base sheet may be solid mopped. spot mopped or mechanically :ned. toss otherwise indicated. all insulations may be hot mopped or mechanically :ned. IFGLAS flashing" or 'Ruberoid' may be used for flashing in any of Use Class or C systems listed below. en 'perlite is referenced. this includes 'GAFTEMP rEF. 1All1Et' or any UL Classified perlite insulation. !shed stone or slag are suitable alternates for gravel in any of the Class A, • C systems listed. ,mutmr.st cement fiber bnildissg units are considered suitable to be included : tk to the following Class A, 0 or C systems listed over C -15/32 or rice use of gypsum board under any of the following Class A. 8 or C systems s not adversely effect the rating. The use of 1/2 in. rain gypsum board is scceptable alternate for :';::ration over C -15/32 decks. o use of polystyrene insulation board between min 3/4 in, perlite board deck with rosin paper (penile /rosin paper /polystyrene /ptrli(e) is a able alternate for isocysn'.rate board in the fallowing Class A, 0 or C :erns. .AtIU P Isotserm 11A•, - CAfirlir Tattered Isotherms F.A' and '6AFTFMr -sposile A' may Ise substituted fur any rsucyanurate Insulation In any of the owing Classifications, Class A, a and C. .,..r•.tr ear use c': orcaniC and glass felts or modified bitumen R1306 (N) o as t:-"= 'p , +T .e� : 7.1► i D r_ Y ° - . ROOFING a w TGFII) ala ;.-1;:q- 4. .? ��fstitalhane'compo "rile: =wood (.1'ber/isocyanurate_ co • pasRe •pliennohc. any ' thickness: = r;__... "`:r�'_c -_ • • hl!? ►'-�• 7::•- k..;.4:;., -e +'�,•-'.%l- i Pty Sheet: Three or-more layers Type GI'GAFGLAS Pty 4' or"GFJGLAS PIy 6';. Isot mopped.' . ',"- .. -.�� c = :. .. Surfacing: GraveL -, . 2. Deck: C•15/32. ..*:.--v-.......,;.,.. . � I„ttine: 2 Insulation (Optional): One or more layers polite, wood, fiber. glass fiber. isocyanurate. urethane. perlite/isocyanurate caarpotite. petlite/ urethane composite. wood fiber /isocyanurate composite_. phenolic. any thickness. ` • Ply Sheet: Three or more layers Type GI'GAFGLAS Ply 4' or 'GAFGLAS Fly .6'. r • Cap Sheet: One layer Type G3 'GAfGLAS Mineral. Surfaced Cap Slseet'. 3. Deck: NC laillne: 2' Insulation (Optional): One or more layers polite. wood fiber. glass fiber. isocyanurate. urethane. pertite/isocyanurate composite. perlite/ urethane composite, wood fiber /isocyanurate composite. phenolic, 2'in. 'sax. Ply Sheet: Two or more layers Type GI 'GAFGLAS Ply 4' or'GAFGLAS Ply 6'. Cap Sheet: One layer Type G3 'GAfGLAS Mineral Sedated Cap Sheet'. 4. Deck: NC . Incline: 1/2 - Insulatlon: One or two layers "Isotherm r, 4.in.. max. hot mopped. Ply Sheet: Any UL Classified gravel surfaced Class A asphalt glass fiber mat system. Iaillne: s 5. "neck: C -I5/32 Slip Sheet (Optional): Red rosin paper. sailed to deck. Base Sheet: One laver of T 62 ' ase Sheer (may be 6. 7. '8. 1. y 4' or GAFGLAS Ply e G -3 'GAFGLAS Mineral Surfa d �• De, . tame: Base Sheet: One layer of Type G2 'GAFGLAS 175 Base Sheet'. Ply Sheet: One or note layers of Type G1 'GAFGLAS IN 4' or GAFGLAS PIy G'. Cap Slseet: One layer of Type G -3 'GA: GLAS Mineral Surfaced Lap Slseet'. Deck: C -15/32 Incline: 2 Insulation: One or more layers petlite. glass fiber. isc:yanurate. urethaane, perlite /isocyanurate composite. perlite / urellane cc» polite. phenolic. 1.0 in. min (offset from plywood joints 6 in.). Base Sheet: One or more layers of Type 61. G2 or 63. Membrane: One or more layers of 'Ruberoid Torch" (smooth or granule). 'Ruberoid Torch Plus' (granule). ' Ruberoid Mop' (smooth or granule) er 'Ruberoid Mop Plus (granule). Cap Slseet: "GAFGLAS Mineral Surfa ced Cap Slseet'. I.ot mopped. Deck: C•1S/32 Incline: 2 Insulation (Optional): One or Inge layers perk:•. wood fiber. 411a55 fiber. isocyanurate. urethane. perlite /isocyanurate composite. petlite/ urethane composite. wood fiber /iso:yanurate cor..;:site. phenolic. an/ thickness. Base Sheet: Two or more layers of T/pe G2 or 63. Ply Sheet (Optional): One or more Byers of Type GI. Membrane: One or more layers of 'Ruberoid Torch' (s soothe or granule).. 'Ruberoid Torch Plus (granule). ' Ruberoid Mop- (s:nootIs or granule) cr 'P.trberoid Mop Plus (granule). Cap Sheet: 'GAFGLAS Mineral Surfa ::d Cap Sheet'. hot mopped. Class E Deck: C.1S /3Z ' Incline: 3.1/2 insulation (Optional): One or r..::: layers pee!: :. wood fiber. g!' %s fiber. isocyassurate. urethane. prlite /isocyanurate composite. r('eiG':/ urethane composite. wood fiber /i ;: yanurale co-, gsite, plsermlit. thickness. Fly Sheet: Two or more layers of Type G1 'GAfGI:.3 ply 4' or '64fGs1•S rt- 6' • Cap Sheet: Type G3'GAFGLAS flinrat �urfane:d3Ca :, Sheet ". hot roprtl. 2. Deck: C -1S /32 .' wood lib :�, Serer Insulation (Optional): One of r.: : :e layers Fe s:ire. fiber. isocyanurate. urethane. prate /isocyanurate composite, faller/ urethane composite. wood fiber /i; :cyanurate ce- ;osite. pliers tic. a "/ thickness. Rase Sheet: Two or mare layers itf Type G1, 67 r.r f . Membrane: (Inc nr mute layers cf 'cubs Told Imrtls' (smooth of grams "fie), 'Ruberoid Torch Plus' (granule), .i'.s:betoid Huy" (smuulis.or gas:ult% ct 'Ruberoid Mop Plus- (granule), Cap Sheet: "GAFGLAS Mineral Susftced Cap Shcet hot mowed- MIAMI•DADE COUNTY BUILDING CODE COMPLIANCE OFFICE (BCCO) PRODUCT CONTROL DIVISION NOTICE OF ACCEPTANCE (NOA) Entegra Sales, Inc. 819 N. Federal Highway, Suite 300 Stuart, FL. 34994 MIAMI -DADE COUNTY, FLORIDA METRO -DADE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 MIAMI, FLORIDA 33130 -1563 (305) 375 -2901 FAX (305) 375 -2908 www.buildinecodeonline.com SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by Miami -Dade County Product Control Division and accepted by the Board of Rules and Appeals (BORA) to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Division that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION: Estate "S" Tile LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This renews NOA # 01- 0703.04 and consists of pages 1 through 7. The submitted documentation was reviewed by Alex Tigera. NOA No. 06- 0310.05 Expiration Date: 08/23/11 Approval Date: 07/27/06 Page 1 of 7 ROOFING ASSEMBLY APPROVAL Category: Sub Category: Material: Roofing Roofing Tiles Concrete 1. SCOPE This renews a roofing system using Entegra Estate "S" Concrete Roof Tile, as manufactured Entegra Roof Tile Corporation in as described in Section 2 of this Notice of Acceptance, designed to comply with the Florida Building Code, 2004 Edition for High Velocity Hurricane Zone. For the locations where the pressure requirements, as determined by applicable Building Code, does not exceed the design pressure values obtain by calculations in compliance with RAS 127 using the values listed in section 4 herein. The attachment calculations shall be done as a moment based system. 2. PRODUCT DESCRIPTION Manufactured by Applicant Entegra Estate 'S' Roof Tile Trim Pieces Dimensions 1= 16 -1/2" w = 13" min. 1/2" thick 1 =varies w = varies varying thickness Test Specifications TAS 112 TAS 112 Product Description Low profile, interlocking, extruded concrete roof tile equipped with two nail hole and double roll ribs. For direct deck or battened nail -on, mortar or adhesive set applications Accessory trim, concrete roof pieces for use at hips, rakes, ridges and valley terminations. Manufactured for each tile profile. 2.1 Components or products manufactured by others Product Rainproof II Ice and Water Shield Wood Battens Dimensions 30" x 75' roll 36" x 75' roll or 60" x 75' roll 36" x 75' roll Vertical Min. 1 "x 4" Horizontal Min. 1 "x 4" for use with vertical battens or Min. 1"x 2" for use alone Test Specifications TAS 104 Product Description Single ply, nail -on underlayment with 2" self - adhering top edge. TAS 103 Self- adhering underlayment Wood Preservers Salt pressure Institute LP — 2 treated or decay resistant lumber battens Manufacturer Protect -O -Wrap, Inc. (with current NOA) W.R. Grace Co. (with current NOA Generic (with current NOA) NOA No. 06- 0310.05 Expiration Date: 08/23/11 Approval Date: 07/27/06 Page 2 of 7 Product Tile Nails Tile Screws Roof Tile Mortar ( "TileTiteTM") Roof Tile Mortar ( "Quikrete® Roof Tile Mortar #1140 ") Roof Tile Mortar ('BONSAL® Roof Tile Mortar Mix ") Roof Tile Adhesive ( "Polypro® AH160 ") Roof Tile Adhesive TileBond Hurricane Clip & Fasteners Dimensions Min. 10dx 3" #8x 21 /s" long 0.335" head dia. 0.131" shank dia. 0.175" screw thread dia. N/A N/A N/A N/A Factory premixed canisters Clips Min. 1/2" width Min. 0.060" thick Clip Fasteners Min. 8d x 1 1 /a" Test Specifications TAS 114 Appendix E TAS 114 Appendix E TAS 123 TAS 123 TAS 123 See PCA See PCA TAS 114 Appendix E Product Description Corrosion resistant screw or smooth shank nails Corrosion resistant, coated, square drive, galvanized, coarse thread wood screws Prepared mortar mix designed for mortar set roof tile applications. Prepared mortar mix designed for mortar set roof tile applications. Prepared mortar mix designed for mortar set roof tile applications. Two component polyurethane adhesive designed for adhesive set roof tile applications. Manufacturer Generic (with current NOA) Generic (with current NOA) Bermuda Roof Company, Inc. with current PCA Quikrete Construction Products with Current PCA W. R. Bonsal Co. with current PCA Polyfoam Products, Inc. Single component Flexible Products polyurethane foam (with current NOA) roof tile adhesive Corrosion resistant Generic clips with corrosion resistant nails. NOA No. 06- 0310.05 Expiration Date: 08/23/11 Approval Date: 07/27/06 Page 3 of 7 3. LIMITATIONS 3.1 Fire classification is not part of this acceptance. 3.2 For mortar or adhesive set tile applications, a static field uplift test shall be performed in accordance with RAS 106. 3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test in accordance with TAS 112, appendix 'A'. Such testing shall be submitted to the Building Code Compliance Office for review. 3.4 Minimum underlayments shall be in compliance with the applicable Roofing Applications Standards listed section 4.1 herein. 3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature. 3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with applicable Building Code. 4. INSTALLATION 4.1.1 Entegra Estate "S" Concrete Roof Tile and its components shall be installed in strict compliance with Miami Dade County Roofing Application Standard RAS 118, RAS 119, and RAS 120. 4.2 Data For Attachment Calculations Table 1: Average Weight (W) and Dimensions (I x w Tile Profile Weight -W (Ibf) Length -I (ft) Wldth -w (ft) Entegra Estate 'S' Roof Tile 10.0 1.375 1.08 Table 3: Restoring Moments due to Gravity - Mg (ft-Ibf) Table 2: Aerodynamic Multipliers - X (ft3) 3 ":12" Tile 5 ":12" X (ft3) 7 ":12" or greater X (ft) Profile Direct Deck Batten Application Direct Deck Application Entegra Estate 'S' Roof Tile Direct Deck 0.267 0.289 Table 3: Restoring Moments due to Gravity - Mg (ft-Ibf) Tile Profile 3 ":12" 4 " :12" 5 ":12" 6 ":12" 7 ":12" or greater Entegra Estate 'S' Roof Tile Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck 5.91 6.74 5.82 6.64 5.70 6.50 5.56 6.33 5.40 N/A NOA No. 06- 0310.05 Expiration Date: 08/23/11 Approval Date: 07/27/06 Page 4 of 7 Tile Profile Entegra Estate 'S' Roof Tile 1 Installation Table 4: Attachment Resistance Expressed as a Moment - Mt (ft-Ibf) for Nail -On Systems Fastener Type Direct Deck (min 15/32" plywood) 2 -10d Ring Shank Nails 1 -10d Smooth or Screw Shank Nail 2 -10d Smooth or Screw Shank Nails 1 #8 Screw 2 #8 Screw 27.8 Direct Deck (min. 19/32" plywood) 37.4 Battens 8.8 11.8 28.8 4.1 16.4 21.9 7.1 25.8 25.8 1 -10d Smooth or Screw Shank Nail (Field Clip) 1 -10d Smooth or Screw Shank Nail (Eave Clip) 2 -10d Smooth or Screw Shank Nails (Field Clip) 2 -10d Smooth or Screw Shank Nails (Eave Clip) 47.1 47.1 24.3 24.3 22.9 49.1 24.2 19.0 19.0 22.1 35.5 35.5 34.8 31.9 31.9 32.2 2 -10d Ring Shank Nails' 1 43.0 1 67.5 1 50.9 with a 4" tile headlap and fasteners are located a min. of 2h" from head of tile. Table 5: Attachment Resistance Expressed as a Moment Mr (ft-Ibf) for Two Patty Adhesive Set Systems Tile Application Minimum Attachment Resistance Tile Profile Entegra Estate 'S' Roof Tile Adhesive 2 See manufactures component approval for installation requirements. 3 Flexible Products Company TileBond Average weight per patty 11.4 grams. Polyfoam Product, Inc Average weight per patty 8 grams. 26.1' Table 5A: Attachment Resistance Expressed as a Moment - Mt (ft -Ibf) for Single Patty Adhesive Set Systems Tile Tile Application Minimum Attachment Profile Entegra Estate 'S' Roof Tile 1 Polyfoam PolyProTM Resistance 86.614 Polyfoam PoiyProTM 4 Large paddy placement of 54 grams of PolyProTM. , 5 Medium paddy placement of 24 grams of PolyProTM. 45.5b Table 5B: Attachment Resistance Expressed as a Moment - M} (ft -Ibf) for Mortar or Adhesive Set Systems Tile Tile Application Til Profile Entegra Estate 'S' goof-Tile Mortar Set Minimum Attachment Resistance 20.60 NOA No. 06- 0310.05 Expiration Date: 08/23/11 Approval Date: 07/27/06 Page 5 of 7 5. LABELING All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo (See Detail Below), or following statement: "Miami -Dade County Product Control Approved ". OR ENTEM-VA ESTATE "S" TILE LABEL (LOCATED ON UNDERSIDE OF TILE) 6. BUILDING PERMIT REQUIREMENTS 6.1 Application for building permit shall be accompanied by copies of the following. 6.1.1 This Notice of Acceptance. 6.1.2 Any other documents required by the Building Official or applicable Building Code in order to properly evaluate the installation of this system. NOA No. 06- 0310.05 Expiration Date: 08/23/11 Approval Date: 07/27/06 Page 6 of 7 Nail Holes PROFILE DRAWING ENTEGRA ESTATE "S" CONCRETE ROOF TILE END OF THIS ACCEPTANCE NOA No. 06- 0310.05 Expiration Date: 08/23/11 Approval Date: 07/27/06 Page 7 of 7 MIAMI•i�iADE COUNTY BUILDING AND NEIGHBORHOOD COMPLIANCE DEPARTMENT (BNC) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NOA) Polyfoam Products, Inc. 11715 Boudreaux Road Tomball, TX 77375 MIAMI -DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175 -2474 T (786) 315 -2590 F (786) 315 -2599 www.miamidademovibuildina/ SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County BNC - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BNC reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Polypro® AII160 LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement "Miami -Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This renews NOA# 06- 0201.02 and consists of pages 1 through 7. The submitted doeumentation was reviewed by Alex Tigera. MANMADE COUNTY APPROVED NOA No.: 11-0124.04 Expiration Date: 05/10/12 Approval Date: 04/14/11 Page 1 of 7 ROOFING COMPONENT APPROVAL: Category: Roofing Sub Category: Roof tile adhesive Materials: Polyurethane SCOPE: This approves Polypro® A11160 as manufactured by Polyfoam Products, Inc. as described in Section 2 of this Notice of Acceptance. For the locations where the design pressure requirements, as determined by applicable building code, does not exceed the design pressure values obtained by calculations in compliance with Roofing Application Standard RAS 127, for use with approved flat, low, and high profile roof tiles system using Polypro® AH 160. Where the attachment calculations are done as a moment based system for single patty placement, and as an uplift based system for double patty systems PRODUCTS MANUFACTURED BY APPLICANT: Product Dimensions Polypro® AH160 N/A Foampro® RTF1000 N/A ProPack ±? 30 & 100 N/A Test Product Description Specifications TAS 101 Two component polyurethane foam adhesive Dispensing Equipment Dispensing Equipment PRODUCTS MANUFACTURED BY OTHERS: Any Miami -Dade County Product Control Accepted Roof Tile Assembly having a current NOA which list moment resistance values with the use of Polypro AH160 roof tile adhesive. PHYSICAL PROPERTIES: Property Density Compressive Strength Tensile Strength Water Absorption Moisture Vapor Transmission Dimensional Stability CIosed Cell Content Test ASTM D 1622 ASTM D 1621 ASTM D 1623 ASTM D 2127 ASTM E 96 ASTM D 2126 ASTM D 2856 Results 1.6 lbs./ft.3 18 PSI Parallel to rise 12 PSI Perpendicular to rise 28 PSI Parallel to rise 0.08 Lbs./Ft2 3.1 Perm / Inch +0.07% Volume Change ® -40° F., 2 weeks +6.0% Volume Change @158 °F., 100% Humidity, 2 weeks 86% Note: The physical properties listed above are presented as typical average values as determined by accepted ASTM test methods and are subject to normal manufacturing variation. MIAM!•DADE COUNTY APPROVED NOA No.: 11- 0124.04 Expiration Date: 05 /10/12 Approval Date: 04/14/11 Page 2 of 7 EVIDENCE SUBMITTED: Test Agency Test Identifier Test Name/Report Date Center for Applied Engineering #94 -060 TAS 101 04/08/94 257818 -1PA TAS 101 12/16/96 25- 7438 -3 SSTD 11 -93 10/25/95 25- 7438 -4 25- 7438 -7 SSTD 11 -93 11/02/95 25 -7492 SSTD 11 -93 12/12/95 Miles Laboratories NB -589 -631 ASTM D 1623 02/01/94 Polymers Division Ramtech Laboratories, Inc. 9637 -92 ASTM E 108 04/30/93 Southwest Research Institute 01 -6743 -011 ASTM E 108 11/16/94 01- 6739- 062141j ASTM E 84 01/16/95 Trinity Engineering 7050.02.96 -1 TAS 114 03/14/96 Celotex Corp. Testing Services 528454 -2 -1 TAS 101 10/23/98 528454 -9 -1 528454 -10 -1 520109 -1 TAS 101 12/28/98 520109 -2 520109 -3 520109 -6 520109 -7 520191 -1 TAS 101 03/02/99 520109 -2 -1 LIMITATIONS: 1. Fire classification is not part of this acceptance. Refer to the Prepared Roof Tile Assembly for fire rating. 2. Polypro® AH160 shall solely be used with flat, low, & high tile profiles. 3. Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120. 4. Roof Tile manufactures acquiring acceptance for the use of Polypro® AH160 roof tile adhesive with their tile assemblies shall test in accordance with TAS 101. 5. Roof Tile manufactures acquiring acceptance for the use of HANDI -STICK roof tile adhesive with their tile assemblies shall test in accordance with TAS 101 with section 10.4 as modified herein. W Ft— MS 2 MIAMMDADE COUNTY APPROVED NOA No.: 11-0124.04 Expiration Date: 05/10/12 Approval Date: 04/14/11 Page 3 of 7 INSTALLATION: 1. Polypro® AH160 may be used with any roof tile assembly having a current NOA that Lists uplift resistance values with the use of Polypro® AH160. 2. Polypro® AH160 shall be applied in compliance with the Component Application section and the corresponding Placement Details noted herein. The roof tile assembly's adhesive attachment with the use of Polypro® AH160 shall provide sufficient attachment resistance, expressed as an uplift based system, to meet or exceed the uplift resistance determined in compliance with Miami -Dade County Roofing Application Standards RAS 127. The adhesive attachment data is noted in the roof tile assembly NOA 3. Polypro® AH160 roof tile adhesive and its components shall be installed in accordance' with Roofmg Application Standard RAS 120, and Polyfoam Products, Inc. Polypro AH160 Operating Instruction and Maintenance Booklet. 4. Installation must be by a Factory Trained 'Qualified Applicator' approved and licensed by Polyfoam Products, Inc. Polyfoam Products Inc. shall supply a list of approved applicators to the authority having jurisdiction. 5. Calibration of the Foampro® dispensing equipment is required before application of any adhesive. The mix ratio between the "A" component and the "B" component shall be maintained between 1.0- 1.15 (A): 1.0 (B). The dispense timer shall be set to deliver 0.0175 to 0.15 pounds per tile as determined at calibration. No other settings shall be approved. 6. Polypro® AH160 shall be applied with Foampro RTF1000 or ProPack+( 30 & 100 dispensing equipment only. 7. Polypro& AH160 shall not be exposed permanently to sunlight. 8. Tiles must be adhered in freshly applied adhesive. Tile must be set within 2 to 3 minutes after Polypro® AH160 has been dispensed. 9. Polypro® AH160 placement and minimum patty weight shall be in accordance with the Placement Details' herein. Each generic tile profile requires the specific placement noted herein. Table 1: Adhesive Placement For Each Generic Tile Profile Tile Profile Placement Detail Single Paddy Weight Min. (grams) Two Paddy Weight per paddy Min. (grams) Flat, Low, High Profiles #1 35 N/A High Profile (2 Piece Barrel) #1 17 /side on cap and 34 /pan N/A Flat, Low, High Profiles #2 24 N/A Flat, Low, High Profiles #3 8 LABELING: All Polypro® AH160 containers shall comply with the Standard Conditions listed herein. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or applicable building code in order to properly evaluate the installation of this system. MIAMI DADE COUNTY APPROVED NOA No.: 11-0124.04 Expiration Date: 05/10/12 Approval Date: 04/14/11 Page 4 of 7 ADHESIVE PLACEMENT DETAIL 1 SINGLE PATTY Nall through plastic cement Vndedapnent Paddy {Beneath 111o) 1) Place enough adhesiva to added 17 to 23 square Inches to contact with the pan fib 2)Tem covets upside down. Place adhesive 1121 / lt40,_ To 1In. Fromoutsidoedge ofcovertllo. Then install the Se. Optional Metot steep OM applications 10 In. Ewe Course Undlortalanont i Nail through plastle anent Keepc a approx. 4In.up tromweephotes Fuels Savo Monte MIAMI•DADE COUNTY APPROVED inP Puke cite eeve duo covet Mo. Abut ba:ond auras of pet Met Enema eave diet pan and cover tlles flush et eeve line. Ewa closure (mortal shown) Weephote Fascia Sheathing Optional Pot km 6lostar on to DfiJ 1 ti NOA No.: 11-0124.04 Expiration Date: 05/10/12 Approval Date: 04/14/11 Page 5 of 7 ADHESIVE PLACEMENT DETAIL 2 SINGLE PATTY Nell through Mastic cement MIAM1.DADE COUNTY APPROVED NOA No.: 11-0124.04 Expiration Date: 05/10/12 Approval Date: 04/14/11 Page 6 of 7 ADHESIVE PLACEMENT DETAIL 3 DOUBLE PATTY Nall through plastic cement Paddy (between tile) Paddy (under tile) • x 3 in. Single paddy an under- layment Single paddy under tile Sigla Paddy on top of tile COSMO In. X 7 In. medium size paddy eave Fascia course only Nall through plastic cornett Nall through plastic cement Underlayment Single paddy under tlie Single paddy between the 2 tn.xT in. medium site paddy ease course only ttrin.x 3 in. 4 in. Single paddy on under- layment Single paddy on top of tile Eave Course Fascia Wormhole Eave closure Drip edge Single paddy between tile PAIn.x 3 In Single paddy on underlayment Single paddy on top of the Eave Come Eave Closure 2 In. x 1 In. medium size paddy save course only Fascia END OF THIS ACCEPTANCE MIAMIttADE COUNIY APPROVED NOA No.: 11-0124.04 Expiration Date: 05/10/12 Approval Date: 04/14/11 Page 7 of 7