RF-11-605Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Inspection Number: INSP - 157996 Permit Number: RF -4 -11 -605 Scheduled Inspection Date: June 03, 2011 Inspector: Bruhn, Norman Owner: KRETZSCHMAR, LOREN Job Address: 9880 NE 8 Avenue Miami Shores, FL 33138- Project: <NONE> Contractor: T&S ROOFING SYSTEMS INC. Permit Type: Roof Inspection Type: Final Roof Work Classification: Tile Phone Number Parcel Number 1132060142370 Phone: 305/265 -2654 Building Department Comments RE -ROOF TILE COLOR THRU TILE Passed ,,f Failed Inspector Comments Correction Needed Re- Inspection Fee No Additional Inspections can be scheduled until re- inspection fee is paid. June 02, 2011 For Inspections please call: (305)762 -4949 Page 2 of 7 Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Inspection Number: INSP - 157997 Permit Number: RF -4 -11 -605 Scheduled Inspection Date: June 03, 2011 Inspector: Bruhn, Norman Owner: KRETZSCHMAR, LOREN Job Address: 9880 NE 8 Avenue Miami Shores, FL 33138- Project: <NONE> Contractor: T&S ROOFING SYSTEMS INC. Permit Type: Roof Inspection Type: Up Lift Report Work Classification: Tile Phone Number Parcel Number 1132060142370 Phone: 305/265 -2654 Building Department Comments RE -ROOF TILE COLOR THRU TILE Inspector Comments Passed Failed Correction Needed Re- Inspection Fee No Additional Inspections can be scheduled until re- inspection fee is paid. June 02, 2011 For Inspections please call: (305)762 -4949 Page 3of7 to A -1 Engineering Inspection Services, Inc 7066 SW 44th Street Miami, Fl 33155 Tel: 786- 326 -9877 Fax: 305 -485 -9011 a1roofinspection@gmail.com LAB CERTIFICATION # 10- 0512 -01 SITE SPECIFIC INFORMATION UPLIFT TEST - TAS #106 Roofing Contractor T & S ROOFING Permit # RF -4-11 -605 Job Address 9880 NE8AVMIAMI Owner's Name LOREN KRETZSHMAR Type of Tile MONIER VILLA 900 Date Installed 5/25/2011 Approximate Roof Height 15 feet Roof Pitch 3/12 Type of access to Roof OK Approximate Square Footage of Roof 31 ft 2 Required Testing Force 35 Ibs Date Tested 5/28/2011 Contact Name SANDRA DUQUE Number of Tests 64 Testing Equipment: F.G.E. 100 Phone # (305) 265 -2654 LOCATION # OF TEST PASS # OF TEST FAIL Corner 7 Tests n Pass 0 Tests Fail Perimeter 11 Tests C] Pass 0 Tests Fail Field 31 Tests L2 Pass 0 Tests Fail Ridge 15 Tests v Pass 0 Tests Fail Total 64 9 Tests k Pass 0 Tests Fail IN ACCORDANCE WITH THE CRITERIA OF ROTOCOL PA 106, THIS ROOF ASSEMBLY HAS PASSED THE STATIC UPLIFT QUALITY CONTROL TEST. THIS TAS 106 TEST HAS BEEN PERFO ED I FULL ACCORDANCE TO THE REQUIREMENTS OF DADE COUNTY, WITH NO DEVIATIONS. THIS REPORT IS NOT GUARANTEED IN CA OF NATUD RS. Cordially REMBERTO CONTRERAS P.E P.E # 21522 A -1 ENGINEERING INSPECTION SERVICES INC CERTIFICATION NO 10- 0512.01 7066 SW 44th Street Miami, Fl 33155 « Telephone (786)326 -9877 Fax (305)485 -9011 A -1 Engineering Inspection Services, Inc 7066 SW 44th Street Miami, Fl 33155 Tel: 786- 326 -9877 Fax: 305 -485 -9011 a 1 roofi nspection ©gmai l.com LAB CERTIFICATION # 10- 0512 -01 SITE SPECIFIC INFORMATION UPLIFT TEST - TAS #106 Roofing Contractor T& SROOFING Permit # RF -4 -11 -605 Job Address 9880 NE8AVMIAMI Owner's Name LOREN KRE7ZSHMAR Type of Tile MONIER VILLA 900 Date Installed 5/25/2011 Approximate Roof Height 15 feet Roof Pitch 3/12 Type of access to Roof OK Required Testing Force 35/bs Date Tested 5/28/2011 Number of Tests 64 Testing Equipment: F.G.E. 100 Approximate Square Footage of Roof 31 ft 2 Contact Name SANDRA DUQUE Phone # (305) 265 -2654 SKETCH OF ROOF Revised by si29IZ0 �t 7066 SW 44th Street Miami, Fl 33155 • Telephone (786) 326 -9877 « Fax (305) 485 -9011 AFFIDAVIT OF COMPLIANCE WITH ROOF DECKING ATTACHMENT AND SECONDARY WATER BARRIER HURRICANE MITIGATION RETROFIT FOR EXISTING SITE -BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES PURSUANT TO SECTION 553.844 F.S. DATE: I I To: Miami Shores Village 10050 NE 2 Avenue Miami Shores, Florida 33138 Re: Owner's Name -&-N -Sc Property Address l <t r e i' k, Roofing Permit Number RE - 4- --/ - Dear Building Official: a I Lcu I E TC., LE D(1) certify that the roof decking attachment and fasteners have been strengthened and corrected and a secondary water barrier has been provided as required by the "Manual of Hurricane Mitigation Retrofits for Existing Site -Built Single Family Structures" adopted by the Florida Building Commission by Rule 9B -3.047 F.A.C. Sign ture`of Qualifying Agent Print Name STATE OF FLORIDA COUNTY OF MIAMI -DADE Sworn to and subscribed before me this ,,,,,,,001"1/1//0/1 day of i1, /4 •,�I , 20 I I ��1%, ° SAA10,, ��, to c (SEAL) mao JAN�4rJ' e°".�`� ,� Personally known Zip L e -a 0 or Produced Ident� cation 4 . r7 NOTICE OF COMMENCEMENT A RECORDED COPY MUST BE POSTED ON THE JOB SITE AT TIME OF FIRST INSPECTION PERMIT NO. TAX FOLIONO.j1- 32Q6- O14 --2_,37O STATE OF FLORIDA: COUNTY OF MIAMI -DADE: STATE OF I HEREBY u tginat frlo i THE UNDERSIGNED hereby gives notice that improvements will be made to c Fn property, and in accordance with Chapter 713, Florida Statutes, the following in ciligg is provided in this Notice of Commencement. By 1111111 11111 1111111111 11111 11111 111111111 1111 : I"I 2n 1 1 R024°l Ic.6 OR Bk 27656 F's 1755; (113s) RECORDED 04/18/2011 11:20:45 HARVEY RUVII4 CLERK OF COURT MIAMI -DADE COUNTY? FLORIDA LAE ;T PANE LORIDA, COUNTY OF DADE R77FY that this is a copy of Me ffals Wfi _ 1 ✓ ?of CormtY COWS Space above reserved for use of recording office 1. Legal description of property and street/address: 1`13C- Sc, NE co u G P 1l /'' r'"t 1 X34 es Si- 0 S SEC 3 A913 c o; 1 r c_ 1 2. Description of improvement: 77 t ' e7-12' ®o d' 3. Owner(s) name and address: 1 C2ACN T. £ . t)f 19N /< % Z H1y � 588 o # • � `� Interest in property: Ch"ior 6.12 /41/0W1/ JJ f Fe— 3 313 9 Name and address of fee simple titleholder. 4. Contractor's name, address and phone number ir ®t-7/ 09,1 5. Surety: (Payment bond required by owner from contractor, if any) Name, address and phone number. Amount of bond $ 6. Lender's name and address: 7. Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)7., Florida Statutes, Name, address and phone number 8. In addition to himself, Owners designates the following person(s) to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b), Florida Statutes. Name, address and phone number. 9. Expiration date of this Notice of Commencement: (the expiration date Is 1 year from the date of recording unless a different date Is specified) WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART I, SECTION 713.13. FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWIG FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMME Signature(s) of Owns or 0 •;,; 1 ■ Prepared By ■. Print Name Title /Office STATE OF FLORIDA COUNTY OF MIAMI -DADE The foregoing instrument was acknowledged before me this By ❑ Individually, or ❑ as for APersonally known, or ❑ produced the following type of identlfi Signature of Notary Public: Print Name: (SEAL) VERIFICATION PURSUANT TO SECTION 92.525. FLORIDA STATUTES Under penalties of perjury, I declare that I have read the foregoing and that the facts stated in it are true, to the best of my knowledge and belief. Signature(s) o •wn5s `�• Authorized Officer /Director /Partner /Manager who signed above: /Director /Partner /Manager Prepared By Print Name V ►`� ` f OETS Title /Office T��k )�1 15`—f !`-I (Di NtA3 ' i c, rn day of 1 on: v'" "'' KRISTINE K. YAO MY COMMISSION # DD957912 ,.e - - EXPIRES February 02, 2014 ,, , ,. (401) 398 -0153 FloridBNotarySarvica.com B 123.01 -52 PAGE 3 3/10 By 1. ACOTZE, CERTIFICATE OF LIABILITY INSURANCE THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER, AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED, the policy(ies) must be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in Ileu of such endorsement(s). IDATE (MM/DD/YYYY) 3/3/2011 PRODUCER Gil, Garden, Avetrani Insurance Group 10689 N. Kendall Drive Suite 208 Miami FL 33176 INSURED T &S Roofing Systems, Inc. 1455 NW 23 Street Miami FL 33142 CONTACT Karla Arevalo NAME: PHONE (305) 630 -4777 (A/C. No. Ext): E-MAIL ADDRESS: ECarevalo@ ggaig . corn PRODUCER 00001984 CUSTOMER ID # IFAX (305) 279 -3022 (A/C. Nol: INSURER(S) AFFORDING COVERAGE NAIC # INSURER A :Gemini Insurance Company INSURER B : INSURER C : INSURER D : INSURER E : INSURER F : COVERAGES CERTIFICATE NUMBER:CL113201373 THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. POLICY EFF POLICY EXP MM/DD MM/DDIYYYY REVISION NUMBER: INSR LTR A TYPE OF INSURANCE GENERAL LIABILITY X COMMERCIAL GENERAL LIABILITY CLAIMS -MADE X OCCUR ADDL SUBR .►n POLICY NUMBER GEM. AGGREGATE LIMIT APPLIES PER: 7 POLICY n JECOT I I LOC AUTOMOBILE LIABILITY ANY AUTO ALL OWNED AUTOS SCHEDULED AUTOS HIRED AUTOS NON -OWNED AUTOS GL61447030311 3/3/2011 3/3/2012 LIMITS EACH OCCURRENCE DATIvAGE TO RENTED PREMISES (Ea occurrence) MED EXP (Any one person) PERSONAL & ADV INJURY $ 1,000,000 $ 5,000 $ 10,000 $ 1,000,000 GENERAL AGGREGATE $ 2,000,000 PRODUCTS - COMP /OP AGG $ 2,000,000 COMBINED SINGLE LIMIT (Ea accident) BODILY INJURY (Per person) BODILY INJURY (Per accident) PROPERTY DAMAGE (Per accident) UMBRELLA LIAB EXCESS LIAB OCCUR CLAIMS -MADE DEDUCTIBLE RETENTION $ WORKERS COMPENSATION AND EMPLOYERS' LIABILITY Y / N ANY PROPRIETOR/PARTNER /EXECUTIVE I ^ I OFFICER/MEMBER EXCLUDED? (Mandatory in NH) If yes, describe under DESCRIPTION OF OPERATIONS below NIA EACH OCCURRENCE AGGREGATE $ $ WC STATU- TORY LIMITS $ OTH- ER E.L. EACH ACCIDENT E.L. DISEASE - EA EMPLOYEE E.L. DISEASE - POLICY LIMIT DESCRIPTION OF OPERATIONS I LOCATIONS / VEHICLES (Attach ACORD 101, Additional Remarks Schedu e, If more space Is required) CERTIFICATE HOLDER City of Miami Shores 10050 NE 2nd Ave. Miami Shores, FL 33138 ACORD 25 (2009/09) INS025 (200909) CANCELLATION $ SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE Joe Avetrani/TM © 1988-2009 ACORD CORPORATION. All rights reserved. The ACORD name and logo are registered marks of ACORD Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 INSPECTION'S PHONE NUMBER: (305) 762.4949 Permit No. I GC!c53 Master Permit No. BUILDING PERMIT APPLICATION FBC 200? Permit Type: BUILDING ROOFING L c_. �.� 'r�, APR 0 6 2011 !!t F1. OWNER: Name (Fee Simple Titleholder): Wen 14 V C +Z rj ckevr a ( Phone #: Address: A gggo l_ Ave City: 1 E (Noi - -e5 Tenant/Lessee Name: State: -L • Zip: c33 j DA Phone#: Email: JOB ADDRESS: !. g go !"-c g Ave City: Miami Shores County: Miami Dade Zip: U-31.3 3g' Folio/Parcel #: 1 I— `/ b- 0 'I - 7j-3 7 0 Is the Building Historically Designated: Yes NO Flood Zone: T CONTRACTOR: Company Name: 14 a S i sie /r15 Phone #: 7 �0 ' 76 t- a�_ Address: )'16( N (a1 2 (/ r� City: J - iGir 1, l State: �ii Zip: D j/ ( 7 Qualifier Name: (,,O U1 S 71100(o Phone#: 3 zo6 -2 ry State Certification or Registration #: c a / Yiro- . Certificate of Competency #: Contact Phone#: AS ?6S ` Email Address: DESIGNER: Architect/Engineer: Phone #: Value of Work for this Permit: $ q,o00 Type of Work: ❑Addition Description of Work: ❑Alteration Square/Linear Footage of Work: ❑ �� New l�ite-pair/Replace 1-1 -e C`o cv -thr Ti 309q ❑Demolition ***** **** *** ****** **** * * * * * * * * * * * * * * ** *Fee *** * * * * ** **** * **** x********* * * * * * * * * * ** ** x Submittal Fee (—PA Permit Fee $ J 5 CCF $ CO /CC $ Scanning Fee $ Radon Fee $ DBPR $ Bond $ Notary $ Training/Education Fee $ Technology Fee $ Double Fee $ Structural Review $ TOTAL FEE NOW DUE $ 3�, 0 ' _if e Bonding Company's Name (if applicable) Bonding Company's Address City Sta ' Zip Mortgage Lender's Name (if applicable) 1 1 \ Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for FT.RCTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC OWNER'S AllNII)AVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature lk-- Owner or Agent The foregoing instrument was acknowledged before me this .1— day of %fit) , 20 ii, by 1(..00 i S et710 who is personally known to me or who has produced As identification and who did NOTA Sign: Pri My ommission Expires: •;001.X, JUAN LORENZO SANCHEZ �' •4 MY COMMISSION # DO987159 EXPIRES April 28, 2014 • ❑.ridBNotaNSeroto• oon , Signature Contractor The foregoing instrument was acknowledged before me this day of ri ,20 ll,by UM S TeCteo// O who is personally known to me or who has produced as identification and who did take an oath. NOTARY Sign: Print: My Commission Expires: JUAN LORENZO SANCHEZ MY CO �� SIO� # DD887158 oom s **********************************. x. x*.x************ **s= ********* ****** ********x ********. x +x***********x:*** ** * *** APPROVED BY Plans Examiner Structural Review (Revised 07 /10 /07)(Revised 06 /10 /2009)(Revised 3/15/09) Zoning Clerk 1461 NW 23 Street Miami, FL 33142 Ph: (305) 265-2654 Fax: (305) 265-2685 rs n modern-day roofing systems POWER OF ATTORNEY State Certified License Number CCC 1326032 Date: Name: Z t'A r},-/ ,KfZ H Address: 9ecvy E AteE 1'1 ii9frl _.51--/ E FL 3:3 r 3 -2- Phone: 3 ()-5- - 7 This letter is to give T & S Roofing Systems, Inc. agent or Louis Toledo, permission to act as my agent when applying for roofing permit. Please read the statement below and sign before a Florida Notary Public. c9 I, eig C21-4 ki.g 7.2---fre "OA , give T & S Roofing Systems, Inc.'s agent or Louis Toledo permission to act as my agent, and to sign my name and do all things necessary when applying for my roofing permit. STATE OF FLORIDA COUNTY OF :1)0, Date The foregoing instrument was acknowledged before me this day of Ekr) A ByLoatri. who is Y.:, personally known or produced as identification. ,200W( 2( Signature of Notary Name of Notary Typed, Stamped or Printed My Commission Expires: 1 tikr KRISTINE K. YAO *".:: MY COMMISSION # DID957912 ExP ES February 02, 2014 T •RrNisisSEAL (407) 398-0153 loridaNstarySenvica.com A MEMBER OF THE BETTER BUSINESS BUREAU www.tsroofingsystems.com Initial ACORD„ CERTIFICATE OF LIABILITY INSURANCE CERTIFICATE NO. l DATE AC11- 26900086.970648 p '/$4/2011 10:41 PM PRODUCER Highpoint Risk Services LLC 14160 Dallas Parkway 4500 Dallas, TX 75254 (800) 632 -5096 (972) 715 -0959 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AMEND, EXTEND OR ALTEP NF r"tWigP4 .A E RDED BY Ttll P =CUES BELOW INSURERS AFFORDING COVERAGE INSURED: AMS 1 /c /f: T & S ROOFING SYSTEMS, INC. 1455 NW 23 ST MIAMI, FL 33142 (305) 265-2654 Fax) (305) 265 -2685 INSURER A' Companion Property and Casualty Insurance C INSURER 8: INSURER C: INSURER 0: INSURER E: rnVFRAfFD THE POUCIES OP INSURANCE US7ED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOT NITHSTAND1NG ANY REQUIREMENT, TERM OR CONDI71oN OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN I3 SUBJECT TO 41.1. THE TERMS; EXCLUSIONS AND CONDITIONS OF SUCH POUCIES, AGGREGATE =TS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. N$R TYPE OF INSURANCE POLICY NU BER POLICY E P V8 PO . CY T ' , OA LIMITS iz E ERAL LIABILITY COMMERCIAL GENERAL UABIUTY EACH OCCURRENCE S F1RE DAMAGE (Any Ong Pic *) 5 MED EXP (Any one Person) 5 1 CLAIMS MADE OCCUR PERSONAL & ADV INJURY $ GENERAL AGGREGATE 5 PRODUCTS - COMP/OP AGG $ OEN'L AGGREGATE LIMIT APPLIES PER 7 PoucY 1 '1 TR 1 PL 1 LOC AUTOMOBILE _ LIABILITY ANY AUTO ALL CONED AUTOS SCHEDULEDAUi08 HIRED AUTOS NON.o NED AUTOS COMBINED SINGLE LIMIT (Ea occtIenI) 8 WANLY INJURY (Per person) $ BODILY WRY ( =r �zlden0 .— 8 ...,.. PROPERTY DAMAGE (Per =Want) 8 GARAGE LIABILITY ANY AUTO AUTO ONLY - EA ACCIDENT $ OTHER THAN EA ACC AUTO ONLY AGO $ EXCESS LIABILITY EACH OCCURRENCE 8 AGGREGATE 5 OCCUR ■ CLAIMS MADE $ DEDUCTIBLE RETENTION 5 5 A WORKERS EMPLOYERS COMPENSATION 4540 LIABILITY WC362727400 04/01/2011 04 / 01 / 2 012 I T4�I T04 1 N E.L,EACHACCIDErtT 8 1000000 EL. D #6A5E.EA EMpLOYEE 3 1000000 E.L. D€SEASE •POLICY LIMIT $ 1000000 OTHER UNITS � 8 LIMITS DESCRIPTION 1. Coverage Applies This OF OPERATIONS ,LOCATIONSNEHICLESIEXCLUSIONS ADDED BY ENDORBEMENTISPECIAI PROVISIONS certificate remains in effect, provided the client's account is in good standing with AMS. is not provided for any a loyyee for which the client is not reporting wages to to 100% of the employees of-AME leased to T & S ROOFING SYSTEMS, INC., effective 04 01 /2011 ADDITIONAL INSURED; INSURER LETTER: CITY OF MIAMI SHORES BUILDING DEPARTMENT 10050 NE 210 AVE MIAMI SHORES, FL 331382304 SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, THE ISSUING INSURER WSJ. ENDEAVOR TO MAIL 30 00 DAYS WRITTEN NOTICE TO THE CERTIFICATE HOLDER NAMED TO THE LEFT, BUT FAILURE TO DO 80 SHALL IMPOSE NO OBLIGATION OR UABIUTY OF ANY KIND UPON THE INSURER, ITS AGENTS OR REPRESENTATIVES. AUTHORIZED REPRESENTATIVE ACORD 254 (7197) �ACORD CORPORATION 1988 ' APR 0672011 SECTION 1524 HIGH VELOCITY HURRICANE ZONES REQUIRED OWNERS NOTIFICATION FO , ,Flepp CONSIDERATIONS °_ ego 1524.1 As it pertains to this section, it is the responsibility of the roofing contractor to provide the owner with the required roofing permit, and to explain to the owner the content of this section.. The provisions of Chapter 15 of the Florida Building Code, Building govem the minimum requirements and standards of the industry for roofing system installations. Additionally, the following items should be addressed as part of. the agreement between the owner and the contractor. The owner's initial in the adjacent box indicates that the item has been explained. 1. Aesthetics-Workmanship: The workmanship provisions of Chapter 15 (High Velocity Hurricane Zone) are for the purpose of providing that the roofing system meets the wind resistance and water intrusion performance standards. Aesthetics (appearance) issues are not a consideration with respect to workmanship provisions. Aesthetic issues such as color or architectural appearance, that are not part of a zoning code, should be addressed as part of the agreement between the owner and the contractor. 2. Renailing Wood Decks: When replacing roofing, the existing wood roof deck may have to be renailed in accordance with the current provisions of Chapter 16 (High Velocity Hurricane Zones) of the Florida Building Code. The roof deck is usually-concealed prior to removing the existing roof system). 3. Common Roofs: Common roofs are those which have no visible delineation between neighboring units (Le. townhouses, condominiums, etc.). In buildings with common roofs, the roofing contractor and /or owner should notify the occupants of adjacent units of roofing work to be performed. 4. Exposed Ceilings: Exposed, open beam ceilings are where the underside of the roof decking can be viewed from below. The owner may wish to maintain the architectural appearance, therefore, roofing nail penetrations of- the underside of the decking may not be acceptable. The Florida Building Code provides the option'of maintaining this appearance. 5. Ponding Water: The current roof system and/or deck of the building may not drain well and may cause water to pond (accumulate) in low-lying areas of the roof. Ponding can be an indication of structural distress and may require the review of a professional structural engineer. Ponding may shorten the life expectancy and performance of the new roofing system. Ponding conditions may not be evident until the original roofing system is removed. Ponding conditions should be corrected. 6. Overflow scuppers (wail outlets): It is required that rainwater flow off so that the roof is not overloaded from a build up of water. Perimeter /edge walls or other roof extensions may block this discharge if overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in accordance with the Florida Building Code, Plumbing. a r7. Ventilation: Most roof structures should have some ability to vent natural airflow through the interior of the structural assembly (the building itself). The existing amount of attic ventilation shall not be reduced. It may be beneficial to consider additional venting which can result in extending the service life of the roof. s r' . Signature COPY 9 -$0, � 1 ( \VE h Alps 5'00 REs BY Property Address 'e umber Rev: ?/20/2005, Computer Services, itdin artmeCOtnf '�RruANce WfNi ALI. FEDERAL STATE AND COUNTY RULES AND REGULATIONS Miami Shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 OWNERS'S AFFIDAVIT OF EXEMPTION ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR EXISTING SITE - BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES PERSUANT TO SECTION 553.844 F.S. To: Miami Shores Village Building Department Date: 10050 NE 2nd Ave Miami Shores, Fl I33138 Re: Owner's Name: 1Q {( Y1 ���' �� 61 V1 0Aei i • .Miami;Dade. My Home My Home it , ade :off. Show Me: Property Information Search By: Select Item Text My Property Appraiser Tax Estimator Property Appraiser Tax Qumparison. Portability S.O.H. Calculator Summary Details: Folio No.: 11- 3206-014 -2370 Property: 880 NE 8 AVE Mailing Address: LOREN T KRETZSCHMAR W SUSAN • 80 NE 8 AVE MIAMI SHORES FL 138 -2509 Property Information: Primary Zone: 1000 SINGLE FAMILY RESIDENCE CLUC: 001 RESIDENTIAL - SINGLE FAMILY Beds/Baths: /2 Floors: 1 Living Units: 1 Ad S Foots e: ,116 Lot Size: 7,969 SQ FT Year Built: 1970 $50,000/ $124,751 IAMI SHORES SEC 3 City: PB 10 -37 LOT 1 BLK 71 Legal 15FT ALLEY LYG S & Description: J PER RES 512 -70 LOT SIZE SITE VALUE OR 18534-0930 03 1999 1 Assessment Information: Year: 2010 2009 Land Value: $119,535 $125,512 Building Value: $190,652 204,840 Market Value: $310,187 $330,352 _ Assessed Value: $174,751 $170,157 Exemption Information: Year: 2010 2009 Homestead: $25,000 $25,000 2nd Homestead: YES YES Taxable Value Information: Year: 2010 2009 Applied Applied Taxing Authority: Exemption/ Taxable Exemption! Taxable Value: Value: Regional: $50,000 / $124,751 $50,000/ $120,157 County: $50,000/ $124,751 $50,000/ $120,157 City: $50,000/ $124,751 $50,000/ $120,157 School Board: $25,000/ $149,751 $25,000/ $145,157 C•ln l..innnefi....• Pe 1 of 2 c 3o 13 ^o,3 ©cam ag ACTIVE T.00L SELECT y Aerial Photography - 2009 0 110 ft 9y._HAMM I PrOPIVIyy..I.nforingtI9n I PrOgrilt ..TAM I MY_Neighborhood 1 Prop5r !_ Appraiser Home I Using Our Site I Phone Directory 1 Privacy I Disclaimer If you experience technical difficulties with the Property Information application, or wish to send us your comments, questions or suggestions please email us at Webmaster. Web Site © 2002 Miami -Dade County. All rights reserved. MIAMIDAD Legend ex Property Boundary Selected Property j Street Highway Miami -Dade County Water , Sect ion A Master Permit No: Contractor's Name: Job Address: High Velocity Hurricalle Zone Roofing pot-Dit Application Fo[D1 Section A (General Information) Process No: [� uLow3lope L� Asphaltic Shingles LI Sprayed Polyurethane Foam ■ El Roof Category Mechanically Fastened Tile Metal Panel/Shingles flar/Adhesive Set Tile Wood Shingles/Shakes Roof Type � New Roof ��ng � Recovering E Repair 0 Maintenance n.,_`' If yes, what type? Natural _ .. �-- _`~~~. .'--_---_ Roof System InformatiOfl Steep Sloped area (h.") Total (ft.') Section B (Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow and oveoW drains. Include =dimensions of sections and levels, clearly identify dimensions ofe|evaUedpneosune zon:s andlooaUoncfpanopeto. Perimeter Width (a'): Corner Size (a' ^ a'): Low slope roof area (ft.') -z_ Miami Shores Village APPROVED BY DATE ZONING DEPT BLDG DEPT SUUJFCT 10 COMPUANCE WITH ALL FEDERAL STATE AND COUNTY RULES AND REGULATIONS Florida Building Code Edition 2007 High Velocity Hurricane Zone Uniform Permit Application Form /stem Section D (St a. Roof System Manufacturer: Slo • ed Roof S Notice Of Acaepiance plumber: S 1 �7 or Calculations): MinimuTi Design U�Iind Pressures, ii Ao)licnhI (From F,A.� s. Pma;:2: Prnag3 ' Z Pma>; f Maximum Design Pressure (From the NOA Specific System): Method of Tile Attachment: Roof Slope: 3 :i2 z6. I hesite 4tr' fe#_ Slo ed Svst.,rn Descri tion ,Deck Type: I S \Type Under ayment: `,Insulation: \\Fire Barrier: Mean Roof Height: _ 6 ` \Fastener Type 8: Spacing: '\Adhesive Type: \Type Cap Sheet `•,Roofing Covering: �. Type & � Tll� Size �•_.dge: Drip Florida Building Cocle Edition 2007 High Velocity Hurricane Zone Uniform Permit Application Form Section E (Tile Calculations �_ ased tile systems, choose either Method 1 or 2.0 the Med the es for values for a area For Moment -based the values from Mr lle the method is aceeptableeG the roof, then the 1 "Moment -Based Tile Calculations Per RAS 127" M NOA M, NOA M, r.2: ,2 1 03 )-I�ig�rlo =M„ •33 - _ Method 2 "Simplified Tile Calculations Per Table Below" M, Required Moment of Resistance (M,) From Table Below NOA M, Required Moment Resistance` Mean Roof Height Roof Slope 2:12 34.4 3:12 32.2 30.4 28.4 26.4 28.0 25.9 27.1 15' 4:12 5:12 6:12 20' 36.5 38.2 39.7 34.4 36.0 39.2 33.8 35.1 30.1 31.6 32.8 20.4 30.5 25' 30' 40' 42.2 37.4 39.8 7:12 24.4 � o conjunction trrith a list of moment -based tile systems endorsed by the Broward `IJiust be u.,.,d in co j County Board of Rules and Appeals. aredchervalues area ofwith roof values for tF . For UF1ivalues the systems use Met to the F, values f If the F' values are greater than or equal attachment method is acceptable. Method 3 "Uplift-Based Tile Calculations Per RAS 127" i0A F' > w:= _)- W:xcos l0: =Fn' NOP,F'�- (Pt;_ xl: __ _)_Vti;xcos 0: =F.,: (2 - VJ: x cos vv: Where to Obtain Information Where to find Symbol I re ued by PE based 00 ASCU 7 Deslglt Pressure P1 or P2 or P3 ; RAS 127 Table 1 or by an engineering analysis P p� H l Job Site N 1 Job Sile I NOA M :IdOP.. I,i Calculated F' i NOA F. ! Calculated 1=. length ' NOA Tile Dimensions y; = i width All calculations must oe supmitteo tO the 3uiiciinu Official at the time of permit application. .J /.3 34.9 32.4 28.2 30.0 Description Mean Roof Height Roof Slope Aerodynamic Multiplier Restoring Moment due l0 Gravity Attacnment Resistance Required Ivioment Resistance Minimum Attachment Resistance Required Uplill Resistance Average Tile Aleioht M I A M I•DADE BUILDING CODE COMPLIANCE OFFICE (BCC()) PRODUCT CONTROL DIVISION NOTICE OF ACCEPTANCE (NOA) Monier Lifetile, LLC 200 Story Road Lake Wales, FL 33853 MIAMI -DADE COUNTY, FLORIDA METRO -DADE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 MIAMJ, FLORIDA 33130 -1563 (305) 375 -2901 FAX (305) 375 -2908 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by Miami -Dade County Product Control Division and accepted by the Board of Rules and Appeals (BORA) to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Division that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code and the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Villa 900 Concrete Roof Tile LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA consists of pages 1 through 7. The submitted documentation was reviewed by Alex Tigera. NOA No.: 06- 0524.02 Expiration Date: 09 /21/11 Approval Date: 09/21/06 Page 1 of 7 ROOFING ASSEMBLY APPROVAL Category: Sub - Category: Material: Roofing Low Profile Roofing Tiles Concrete 1. SCOPE This renews a system using Monier Lifetile Villa 900 Concrete Roof Tile, as manufactured Monier Lifetile LLC in Lake Wales, FL. and described in Section 2 of this Notice of Acceptance. For locations where the pressure requirements, as determined by applicable Building Code does not exceed the design pressure values obtained by calculations in compliance with RAS 127 using the values listed in section 4 herein. The attachment calculations shall be done as a moment based system. 2. PRODUCT DESCRIPTION Manufactured by Test Applicant Dimensions Specifications Monier Lifetile LLC 1= 17" TAS 112 Villa 900 w =13" 1/2" thick Trim Pieces 1= varies w = varies varying thickness 2.1 SUBMITTED EVIDENCE: Test Agency, Nutting Engineers Redland Technologies Redland Technologies Redland Technologies The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. Redland Technologies TAS 112 Test Identifier Product Description Low profile, interlocking, high pressure extruded concrete roof tile equipped with one nail hole and double roll ribs. For direct deck or battened nail -on, mortar or adhesive set applications. Accessory trim, concrete roof pieces for use at hips, rakes, ridges and valley terminations. Test Name/Report 13343.1 TAS 112 7161 -03 Static Uplift Testing Appendix III TAS 102 & TAS 102(A) 7161 -03 Wind Tunnel Testing Appendix II TAS 108 (Nail -On) P0402 Withdrawal Resistance Testing of screw vs. smooth shank nails 94 -060B Static Uplift Testing TAS 101 (Adhesive Set) 94-084 Static Uplift Testing TAS 101 (Mortar Set) P0631 -01 Wind Tunnel Testing TAS 108 (Mortar Set) Date Apr. 2006 Dec. 1991 Dec. 1991 Sept. 1993 March, 1994 May 1994 July 1994 NOA No.: 06- 0524.02 Expiration Date: 09/21/11 Approval Date: 09/21/06 Page 2 of 7 Test A2encv Redland Technologies The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. Celotex Corporation Testing Services Walker Engineering, Inc. Walker Engineering, Inc. Walker Engineering, Inc. Walker Engineering, Inc. Walker Engineering, Inc. Walker Engineering, Inc. Walker Engineering, Inc. Test Identifier Letter Dated Aug. 1, 1994 Project No. 307025 Test #MDC -76 25- 7183 -1 25- 7183 -2 25- 7214 -2 25- 7214 -6 528454 -2 -1 520109 -2 Evaluation Calculations Evaluation Calculations Evaluation Calculations Evaluation Calculations Evaluation Calculations Evaluation Calculations Evaluation Calculations Test Name/Renort Wind Tunnel Testing TAS 108 (Nail -On) Wind Driven Rain TAS 100 Static Uplift Testing TAS 102 (2 Quik -Drive Screws, Direct Deck) Static Uplift Testing TAS 102 (2 Quik -Drive Screws, Battens) Static Uplift Testing TAS 102 (1 Quik -Drive Screw, Direct Deck) (1 Quik -Drive Screw, Battens) Static Uplift Testing TAS 101 25 -7183 25 -7094 25 -7496 25 -7584 25- 7804b -8 25 -7804-4 & 5 25- 7848 -6 Aerodynamic Multipliers Two Patty Adhesive Set System Restoring Moment Due to Gravity Date Aug. 1994 Oct. 1994 Feb. 1995 Feb. 1995 March, 1995 Sep. 1998 Dec. 1998 March 1995 February 1996 April 1996 December 1996 May 2006 April 1999 April 2006 NOA No.: 06- 0524.02 Expiration Date: 09/21/11 Approval Date: 09/21/06 Page 3 of 7 3. LIMITATIONS 3.1 Fire classification is not part of this acceptance. 3.2 For mortar or adhesive set tile applications, a static field uplift test shall be performed in accordance with RAS 106. 3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test in accordance with TAS 112, appendix 'A'. Such testing shall be submitted to the Building Code Compliance Office for review. 3.4 Minimum underlayment shall be in compliance with the applicable Roofmg Applications Standards listed section 4.1 herein. 3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature. 3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with applicable building code. 4. INSTALLATION 4.1 Monier Lifetile Villa 900 Concrete Roof Tile and its components shall be installed in strict compliance with Roofmg Application Standard RAS 118, RAS 119, and RAS 120. 4.2 Data For Attachment Calculations Table 2: Tile Profile Monier Lifetile Villa 900 Concrete Tile Aerodynamic Multipliers - X (ft3) (ft3) Batten Application 0.289 (ft) Direct Deck Application 0.289 Table 3: Restoring Moments due to Gravity - M„ (ft-Ibf) Table 1: Average Weight (W) and Dimensions (1 x w Tile Profile Weight -W (Ibf) Length -I (ft) Width -w (ft) Monier Lifetile Villa 900 Concrete Tile 10.94 1.425 1.08 Battens Table 2: Tile Profile Monier Lifetile Villa 900 Concrete Tile Aerodynamic Multipliers - X (ft3) (ft3) Batten Application 0.289 (ft) Direct Deck Application 0.289 Table 3: Restoring Moments due to Gravity - M„ (ft-Ibf) Tile Profile 3 °:12" 4 °:12" 5 ":12" 6 ":12" 7 ":12" or greater Monier Lifetile Villa 900 Concrete Tile Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck 6.79 7.70 6.73 7.62 6.63 7.51 6.50 7.37 6.36 7.21 NOA No.: 06- 0524.02 Expiration Date: 09/21/11 Approval Date: 09/21/06 Page 4 of 7 Table 4: Attachment Resistance Expressed as a Moment - Mf (ft-lbf) for Nail -On Systems Tile Profile Fastener Type Direct Deck (min 15/32" plywood) Direct Deck (min. 19/32" plywood) Battens Monier Lifetile Villa 900 Concrete Tile 2 -10d Ring Shank Nails 27.8 37.4 28.8 1 -10d Smooth or Screw Shank Nail 8.8 11.8 41 2 -10d Smooth or Screw Shank Nails 16.4 21.9 7.1 1 #8 Screw 25.8 25.8 22.9 2 #8 Screw 47.1 47.1 49.1 1 -10d Smooth or Screw Shank Nail (Field Clip) 24.3 24.3 24.2 1 -10d Smooth or Screw Shank Nail (Eave Clip) 19.0 19.0 22.1 2 -10d Smooth or Screw Shank Nails (Field Clip) 35.5 35.5 34.8 2 -10d Smooth or Screw Shank Nails (Eave Clip) 31.9 31.9 32.2 Table 5A: Attachment Resistance Expressed as a Moment - Mf (ft-Ibf) for Single Patty Adhesive Set Systems Table 5: Attachment Resistance Expressed as a Moment M1 (ft-Ibf) for Two Patty Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Monier Lifetile Villa 900 Concrete Tile Adhesive2 26.13- 1 See manufactures component approval for installation requirements. 2 Flexible Products Company TileBond Average weight per patty 11.4 grams. Polyfoam Product Inc. Average wei ht per patty 8 grams. Table 5A: Attachment Resistance Expressed as a Moment - Mf (ft-Ibf) for Single Patty Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Monier Lifetile Villa 900 Concrete Tile Polyfoam PolyProTM 86.61" Polyfoam PolyProTM 45.5' 3 Large paddy placement of 54grams of PolyProTM. 5 Medium paddy placement of 24grams of PolyProTM. NOA No.: 06- 0524.02 Expiration Date: 09/21/11 Approval Date: 09/21/06 Page 5 of 7 Table 5B: Attachment Resistance Expressed as a Moment - Mf (ft-Ibf) for Mortar Set Systems Tile Profile Monier Lifetile Villa 900 Concrete Tile Tile Application Mortar Set' Attachment Resistance 20.60 5. LABELING All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo, or following statement: "Miami -Dade County Product Control Approved ". LABEL FOR VILLA 900 CONCRETE TILE (LOCATED ON THE UNDERSIDE OF TILE) 6. BUILDING PERMIT REQUIREMENTS 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance. 6.1.2 Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this system. NOA No.: 06- 0524.02 Expiration Date: 09/21/11 Approval Date: 09/21/06 Page 6 of 7 PROFILE DRAWING 2116" MoNIER LIFETILE VILLA 900 CONCRETE RooF TILE END OF THIS ACCEPTANCE r NOA No.: 06- 0524.02 Expiration Date: 09/21/11 Approval Date: 09/21/06 Page 7 of 7 MIA MI•DA E BUILDING CODE COMPLIANCE OFFICE (BCCO) PRODUCT CONTROL DIVISION NOTICE OF ACCEPTANCE (NOA) Polyfoam Products, Inc. 11715 Boudreaux Road Tomball, TX 77375 MIAMI -DADE COUNTY, FLORIDA METRO -DADE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 MIAMI, FLORIDA 33130 -1563 (305) 375 -2901 FAX (305) 375 -2908 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by the BCCO and accepted by the Building Code and Product Review Committee to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The BCCO (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BCCO reserves the right to revoke this acceptance, if it is determined by BCCO that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Polypro® AH160 RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA No.01- 0521.02 and consists of pages 1 through 7 The submitted documentation was reviewed by Jorge L. Acebo. NOA No.: 06- 0201.02 Expiration Date: 05/10/11 Approval Date: 04 /13/06 Page 1 of 7 ROOFING ASSEMBLY APPROVAL: Category: Sub Category: Materials: Roofing Roof tile adhesive Polyurethane SCOPE: This approves Polypro® AH160 as manufactured by Polyfoam Products, Inc. as described in Section 2 of this Notice of Acceptance. For the locations where the design pressure requirements, as determined by applicable building code, does not exceed the design pressure values obtained by calculations in compliance with Roofing Application Standard RAS 127, for use with approved flat, low, and high profile roof tiles system using PolyprolD AH 160. Where the attachment calculations are done as a moment based system for single patty placement, and as an uplift based system for double patty systems PRODUCTS MANUFACTURED BY APPLICANT: Product Polypro® AH160 Foampro® RTF1000 ProPacloD 30 & 100 Dimensions Test Specifications N/A TAS 101 N/A N/A Product Description Two component polyurethane foam adhesive Dispensing Equipment Dispensing Equipment PRODUCTS MANUFACTURED BY OTHERS: Any Miami -Dade County Product Control Accepted Roof Tile Assembly having a current NOA which list moment resistance values with the use of Polypro AH160 roof tile adhesive. PHYSICAL PROPERTIES: Property, Density Compressive Strength Tensile Strength Water Absorption Moisture Vapor Transmission Dimensional Stability Closed Cell Content Note: Test ASTM D 1622 ASTM D 1621 ASTM D 1623 ASTM D 2127 ASTM E 96 ASTM D 2126 ASTM D 2856 Results 1.6 lbs. /ft.3 18 PSI Parallel to rise 12 PSI Perpendicular to rise 28 PSI Parallel to rise 0.08 Lbs./Ft2 3.1 Perm / Inch +0.07% Volume Change @ -40° F., 2 weeks +6.0% Volume Change @158°F., 100% Humidity, 2 weeks 86% The physical properties listed above are presented as typical average values as determined by accepted ASTM test methods and are subject to normal manufacturing variation. NOA No.: 06- 0201.02 Expiration Date: 05/10/11 Approval Date: 04/13/06 Page 2 of 7 EVIDENCE SUBMITTED: Test Agency Test Identifier Test Name/Report Date Center for Applied Engineering #94 -060 TAS 101 04/08/94 257818 -1PA TAS 101 12/16/96 25- 7438 -3 SSTD 11 -93 10/25/95 25- 7438 -4 25- 7438 -7 SSTD 11 -93 11/02/95 25 -7492 SSTD 11 -93 12/12/95 Miles Laboratories NB -589 -631 ASTM D 1623 02/01/94 Polymers Division Ramtech Laboratories, Inc. 9637 -92 ASTM E 108 04/30/93 Southwest Research Institute 01 -6743 -011 ASTM E 108 11/16/94 01- 6739- 062b[1] ASTM E 84 01/16/95 Trinity Engineering 7050.02.96 -1 TAS 114 03/14/96 Celotex Corp. Testing Services 528454 -2 -1 TAS 101 10/23/98 528454 -9 -1 528454 -10 -1 520109 -1 TAS 101 12/28/98 520109 -2 520109 -3 520109 -6 520109 -7 520191 -1 TAS 101 03/02/99 520109 -2 -1 LIMITATIONS: 1. Fire classification is not part of this acceptance. Refer to the Prepared Roof Tile Assembly for fire rating. 2. Polypro® AH160 shall solely be used with flat, low, & high tile profiles. 3. Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120. 4. Roof Tile manufactures acquiring acceptance for the use of Polypro® AH160 roof tile adhesive with their tile assemblies shall test in accordance with TAS 101. 5. Roof Tile manufactures acquiring acceptance for the use of HANDI -STICK roof tile adhesive with their tile assemblies shall test in accordance with TAS 101 with section 10.4 as modified herein. iF' W 2 MS NOA No.: 06- 0201.02 Expiration Date: 05/10/11 Approval Date: 04/13/06 Page 3 of 7 INSTALLATION: 1. Polypro® AH160 may be used with any roof tile assembly having a current NOA that lists uplift resistance values with the use of Polypro'1) AH160. 2. Polypro® AH160 shall be applied in compliance with the Component Application section and the corresponding Placement Details noted herein. The roof tile assembly's adhesive attachment with the use of Polypro® AH160 shall provide sufficient attachment resistance, expressed as an uplift based system, to meet or exceed the uplift resistance determined in compliance with Miami -Dade County Roofing Application Standards RAS 127. The adhesive attachment data is noted in the roof tile assembly NOA 3. Polypro® AH160 roof tile adhesive and its components shall be installed in accordance with Roofmg Application Standard RAS 120, and Polyfoam Products, Inc. Polypro® AH160 Operating Instruction and Maintenance Booklet. 4. Installation must be by a Factory Trained 'Qualified Applicator' approved and licensed by Polyfoam Products, Inc. Polyfoam Products Inc. shall supply a list of approved applicators to the authority having jurisdiction. 5. Calibration of the Foampro® dispensing equipment is required before application of any adhesive. The mix ratio between the "A" component and the "B" component shall be maintained between 1.0- 1.15 (A): 1.0 (B). The dispense timer shall be set to deliver 0.0175 to 0.15 pounds per tile as determined at calibration. No other settings shall be approved. 6. Polypro® AH160 shall be applied with Foampro RTF1000 or ProPack® 30 & 100 dispensing equipment only. 7. Polyprolil AH160 shall not be exposed permanently to sunlight. 8. Tiles must be adhered in freshly applied adhesive. Tile must be set within 2 to 3 minutes after Polypro® AH160 has been dispensed. 9. Polypro® AH160 placement and minimum patty weight shall be in accordance with the Placement Details' herein. Each generic tile profile requires the specific placement noted herein. Table 1: Adhesive Placement For Each Generic Tile Profile Tile Profile Placement Detail Single Paddy Weight Min. (grams) Two Paddy Weight per paddy Min. (grams) Flat, Low, High Profiles #1 35 N/A High Profile (2 Piece Barrel) #1 17 /side on cap and 34 /pan N/A Flat, Low, High Profiles #2 24 N/A Flat, Low, High Profiles #3 8 LABELING: All Polypro® AH160 containers shall comply with the Standard Conditions listed herein. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or applicable building code in order to properly evaluate the installation of this system. NOA No.: 06- 0201.02 Expiration Date: 05/10/11 Approval Date: 04/13/06 Page 4 of 7 ADHESIVE PLACEMENT DETAIL 1 SINGLE PATTY Nail through plastic cement Underlaymont Paddy (Beneath Tile) Eaves Course • Fascia adhesive amuse only Eave Closure adhve opp 41n. up from weephole 10 in. Nail through plastic cement Undodayment Paddy (Beneath Tile) 1) Place enough adhesive to achieve 17 to 23 Optional2x4s for square inches in contact with the pantile Pal aprons 2)Tum covers upside Place ad a 112 I. rsnid Then install the tile. 10 in. 2 in Eave Course Eave Closure Eave course only. Keep adhesive approx 4ht. up from weepholes Fascia Rem top portion of the eaves course cover tile. Abut to second course of pan tile. Ensure cave end of pan and cover tiles am flush at eave Me. Eava closure (mortar shown) Optional Point-up Mortar on longitudinal edges of Ole NOA No.: 06- 0201.02 Expiration Date: 05/10/11 Approval Date: 04/13/06 Page 5 of 7 ADHESIVE PLACEMENT DETAIL 2 SINGLE PATTY Nall through plastic cement 04 � 7 in. Underlayment 1 Paddy (Beneath He) Eave Case Fascia Weephole Eave closure Drip edge Nall through plastic cement Paddy (Beneath Tile) Underlaayment 7 in. n. Eave Closure Eave Coarse Fascia NOA No.: 06- 0201.02 Expiration Date: 05/10/11 Approval Date: 04/13/06 Page 6 of 7 ADHESIVE PLACEMENT DETAIL 3 DOUBLE PATTY Nail through plastic cement Paddy (between tile) Paddy (under tile) *in. I x3in. Single paddy on under - layment Single paddy under tile 11111401P f ��Eave course 2 In. X 7 in. medium size paddy eave Fascia course only Single paddy on top of the Nail through plastic cement Underlayment Single paddy under tile Single paddy between tile 2 in. x7 hi. medium size paddy eave course only g 3 in. x 3 in. Single 4 PaIdyon under - iayment Single paddy on top of tile Eave Course Fascia Wosphole Eave closure Drip edge Nail through plastic cement Single paddy between tile - 3in.x3In. Single /paddy on underlayment Single paddy on top of tile Eave Course Eave Closure 2 in. x 7In. medium F size paddy save course only END OF THIS ACCEPTANCE NOA No.: 06- 0201.02 Expiration Date: 05/10/11 Approval Date: 04 /13/05 Page 7 of 7 MIA MMADE BUILDING CODE COMPLIANCE OFFICE (BCCO) PRODUCT CONTROL DIVISION NOTICE OF ACCEPTANCE (NOA) Polyglass USA Inc. 150 Lyon Drive Fernley, NV 89408 MIAMI -DADE COUNTY, FLORIDA METRO -DADE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 MIAMI, FLORIDA 33130 -1563 (305) 375 -2901 FAX (305) 375 -2908 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by Miami -Dade County Product Control Division and accepted by the Board of Rules and Appeals (BORA) to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). his NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Division that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code and the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Polystick MTS, IR -Xe, TU, TU Plus and TU P LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following, statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA No. 08- 0929.03 and consists of pages 1 through 6. The submitted documentation was reviewed by Jorge L. Acebo. NOA No.: 09- 0806.07 Expiration Date: 09/13/11 Approval Date: 03/31/10 Page 1 of 6 ROOFING COMPONENT APPROVAL Category: Sub - Category: Material: PRODUCTS DESCRIPTION: Product Polystick MTS underlayment Manufacturing Location #2 Polystick IR -Xe underlayment Manufacturing Location #1 & #2 Polystick TU underlayment Manufacturing Location #1 & #2 Polystick TU Plus underlayment (Facer of Membrane Labeled in Orange or Black Ink) Manufacturing Location #1 & #2 Polystick TU P underlayment Manufacturing Location #2 Roofing Underlayment SBS , APP Self- Adhering Modified Bitumen Dimensions Roll: 65'8" x 3'3-3/8" 60 mils thick Roll: 65'8" x 3'33/8„ 80 mils thick Roll: 32'10" x 3'3-3/8" 100 mils thick Roll: 65'8" x 3'33/8" 80 mils thick Roll: 32'10" x 3'3 -3/8" 130 mils thick Test Product Specification Description TAS 103 A homogeneous, rubberized asphalt waterproofing membrane, glass fiber reinforced with polyolefinic film on the upper surface for use as an underlayment for metal roofing, roof tile, slate tiles and shingle underlayment. TAS 103 and ASTM D 1970 TAS 103 and ASTM D 1970 TAS 103 and ASTM D 1970 TAS 103 and ASTM D 1970 MANUFACTURING PLANTS: 1. 555 Oakridge Road, Hazelton, PA 2. 621 Sniveley Avenue, Winter Haven, FL A fine granular /sand top surface self - adhering, APP polymer modified, fiberglass reinforced, bituminous sheet material for use as an underlayment in sloped roof assemblies. Designed as an ice & rain shield and as a flat roof tile underlayment. A heavy granuled surface self adhering, APP polymer modified, fiberglass or polyester reinforced, bituminous sheet material for use as an underlayment in sloped roof assemblies. Designed as a a roof tile underlayment. A non - wicking fabric surfaced, self-adhering, APP polymer modified, fiberglass reinforced with a high strength polyester fabric, bituminous sheet material for use an an underlayment in sloped roof assemblies. Designed as a metal roofing and roof tile underlayment. A rubberized asphalt waterproofing membrane, glass- fiber /polyester reinforced, with a granular surface designed for use as a tile roof underlayment. NOA No.: 09- 0806.07 Expiration Date: 09 /13/11 Approval Date: 03/31/10 Page 2 of 6 EVIDENCE SUBMITTED: Test Agency Exterior Research & Design, LLC . Trinity I ERD PRI Asphalt Technologies Momentum Technologies, Inc. Test Identifier #11756.04.01 -1 #11756.08.01 -1 #02202.08.05 #P5110.08.07 P10870.09.08 -R1 P10870.04.09 PRI01111 PUSA - 005 -02 -01 PUSA- 018 -02 -01 PUSA -035 -02 -01 PUSA- 033 -02 -01 PUSA -055 -02 -02 PUSA- 083 -02 -01 PUSA - 089 -02 -01 JX20H7A RX14E8A DX23D8B DX23D8A TAS TAS TAS TAS TAS TAS Test Name/Report 103 ASTM D 1970 TAS 103 TAS 103 TAS 103 103 /ASTM D4798 & G155 ASTM D 4977 ASTM D 4977 ASTM D 2523 TAS 103 ASTM D 1970 TAS 103 TAS 103 103 /ASTM D4798 & G155 103 /ASTM D4798 & G155 103 /ASTM D4798 & G155 103 /ASTM D4798 & G155 103 /ASTM D4798 & G155 Date 04/27/01 08/14/01 08/29/05 08/29/07 12/04/08 04/13/09 04/08/02 01/31/02 07/14/03 09/29/06 01/12/06 12/10/07 06/30/08 07/06/09 04/01/08 11/09/09 02/18/10 02/18/10 INSTALLATION PROCEDURES: Deck Type 1: Wood, non - insulated Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626. Fastening: Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4" head lap. (for base sheet only) Membrane: Polystick membranes self- adhered. Surfacing: None 1. All nails in the deck shall be carefully checked for protruding heads. Re- fasten any loose decking panels, and sweep the deck thoroughly to remove any dust and debris prior to application. 2. Place the underlayment over metal drip edge in accordance with RAS 111. 3. Place the first course of membrane parallel to the eave, rolling the membrane to obtain maximum contact. Remove the release film as the membrane is applied. . All side laps shall be a minimum of 3 - %2" and end laps shall be a minimum of 6." Roll the membrane into place after removing the release strip. Vertical strapping of the roof with Polystick is acceptable. Membrane shall be back nailed in accordance with applicable building code. 4. When applying the membrane in the valley, start at the low point and work to the high point, rolling the membrane from the center outward in both directions. 5. For ridge applications, center the membrane and roll from the center outward in both directions. 6. Roll or broom the entire membrane surface so as to have full contact with the surface, giving special attention to lap areas. 7. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control Notice of Acceptance. 8. All protrusions or drains shall be initially taped with a 6" piece of underlayment. The flashing tape shall be pressed in place and formed around the protrusion to ensure a tight fit. A second layer of Polystick shall be applied over the underlayment. NOA No.: 09- 0806.07 Expiration Date: 09/13/11 Approval Date: 03/31/10 Page 3 of 6 GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance. 2. Polystick MTS and TU Plus may be used in asphaltic shingles, wood shakes and shingles, non - structural metal roofing, roof tile systems and quarry slate roof assemblies. IR -Xe, TU, and TU P may be used in all the previous assemblies listed except metal roofing. 3. Deck requirements shall be in compliance with applicable building code. 4. Polystick membranes shall be applied to a smooth, clean and dry surface. The deck shall be free of irregularities. 5. Polystick membranes shall not be adhered directly over a pre - existing roof membrane as a recover system. 6. The following membranes manufactured in Winter Haven, FL Plant; Polystick MTS, IR Xe, TU, TU P and TU Plus shall not be left exposed as a temporary roof for longer than 180 days after application. Polystick TU Plus manufactured in Hazelton, PA Plant shall not be left exposed as a temporary roof for longer than 180 days after application. Polystick IR -Xe and TU manufactured in Hazelton, PA Plant shall not be left exposed as a temporary roof for longer than 30 days after application. Polyglass reserves the right to revise or alter product exposure times; not to exceed the preceeding maximum time limitations. 7. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9B -72 of the Florida Administrative Code. 8. In roof tile application, data for the attachment resistance of roof tiles shall be as set forth in the roof tile manufacturer's Notice of Acceptance. Polystick TU and 111 Plus may be used in both adhesive set and mechanically fastened roof tile applications. Polystick IR -Xe is limited to mechanically fastened roof tile applications. Polystick MTS is limited to mechanically fastened with battens roof tile applications. Polystick TU P may be used in both adhesive set and mechanically fastened roof tile applications with the exception of mortar set tile applications. 9. The maximum roof slope for use as roof tile underlayment for (direct -to -deck) tile assemblies shall be as follows: (See Table Below) Tile Profile Polystick MTS Polystick IR Xe Polystick TU, TU Plus TU P Flat Tile Prohibited without battens 5:12 No limitation Profiled Tile Prohibited without battens Prohibited No limitation The above slope limitations can be exceeded only by using battens and counter battens in accordance with the Approved Tile System Notice of Acceptance and applicable Florida Building Code requirements. Polystick MTS shall not be used in direct -to -deck applications. Battens are required for both loading and installation of tiles at all times. 10. Care should be taken during the loading procedure to keep foot traffic to a minimum and to avoid dropping of tile directly on the underlayment. Refer to Polyglass' Tile loading detail below for loading procedure for all underlayments except Polystick MTS which shall be loaded onto battens. 0 0. 0 n N Roofing Tiles (6 Max Per Stack) 12 6 000 NOA No.: 09- 0806.07 Expiration Date: 09/13/11 Approval Date: 03/31/10 Page 4 of 6 GENERAL LIMITATIONS: (CONTINUED) 11. Refer to prepared roofmg system Product Control Notice of Acceptance for listed approval of this product with specific prepared roofing products. Polystick MTS, IR -Xe, TU, TU Plus and TU P may be used with any approved roof covering Notice of Acceptance listing Polystick MTS, IR -Xe, TU, TU Plus and TU P as a component part of an assembly in the Notice of Acceptance. If Polystick MTS, IR -Xe, TU, TU Plus and TU P is not listed, a request may be made to the Authority Having Jurisdiction (AHJ) or the Miami -Dade County Product Control Department for approval provided that appropriate documentation is provided to detail compatibility of the products, wind uplift resistance, and fire testing results. LABELING: 1. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city and state of manufacturing facility and the following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade County Product Control Seal as shown below. BUILDING PERMIT REQUIREMENTS: Application for building permit shall be accompanied by copies of the following: 1. This Notice of Acceptance. 2. Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this materials. POLYGLASS GENERAL APPLICATION GUIDELINES FOR POLYSTICK MEMBRANES: 1. Polyglass does accept the direct application of Polystick underlayment membranes to wood decks. Installers are cautioned to refer to applicable local building codes prior to direct deck installation to ensure this is acceptable. Please also refer to applicable Product Data Sheets of the corresponding products. 2. All rolls, with the exception of Polystick TU Plus should be back - nailed in selvage edge seam as per Polyglass Back Nailing Guide. Nails shall be, 11 gauge ring shank type, applied with a minimum 1" metal disk as required in Dade County or simplex type nail as otherwise allowable in other regions, at a minimum rate of 12" o.c. Polystick TU Plus should be back nailed in designated area marked "nail area, area para clavar" on the face of membrane, with the above stated nails and/or disks. The head lap membrane is to cover the area being back-nailed. (Please refer to applicable local building codes prior to installation.) 3. All seal lap seams (selvage laps) must be rolled with a hand roller to ensure full contact. 4. All fabric over fabric; and granule over granule end laps, shall have a 6" wide, uniform layer of Polyglass Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, Polyglass PG500 MB Flashing Cement, Mule -Hide 241 Premium Modified Flashing Cement, Mule -Hide 251 Premium Wet/Dry Elastomeric Flashing Cement, or Mule -Hide 421 Mod Bit Flashing Adhesive Trowel Grade mastic, applied in between the application of the lap. The use of mastic between the laps does not apply to Polystick MTS. NOA No.: 09- 0806.07 Expiration Date: 09/13/11 Approval Date: 03/31/10 Page 5 of 6 5. A maximum of 6 tiles per stack are allowed when loading tile on the underlayments. Refer to the Polyglass Tile Loading Guidelines. See General Limitations #9 and #10. 6. Battens and/or Counter - battens, as required by the tile manufacturers NOA's, must be used on all projects for pitch/slopes of 7 "/12" or greater. It is suggested that on pitch/slopes in excess of 6 1/4"/12 ", precautions should be taken, such as the use of battens to prevent tile sliding during the loading process. 7. Minimum cure time after membrane installation & before loading of roofing tiles is Forty-Eight (48) Hours. 8. Polystick membranes may not be used in any exposed application such as crickets, exposed valleys, or exposed roof to wall details. 9. Repair of Polystick membranes is to be accomplished by applying Polyglass Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, Polyglass PG500 MB Flashing Cement, Mule -Hide 241 Premium Modified Flashing Cement, Mule -Hide 251 Premium Wet/Dry Elastomeric Flashing Cement, or Mule -Hide 421 Mod Bit Flashing Adhesive Trowel Grade mastic to the area in need of repair, followed by a patch of the Polystick material of like kind should be set and hand rolled in place over the area needing such repair. Patching membrane shall be a minimum of 6 inches in either direction. The repair should be installed in such a way so that water will run parallel to or over the top of all laps of the patch. 10. All self - adhered membranes must be rolled to ensure full contact with approved substrates. Polyglass requires a minimum of 40 lbs for a weighted roller for the rolling of the field membrane. Hand rollers are acceptable for rolling of patches or small areas of the roof. Brooming may be used where slope prohibits rolling. 11. All approved substrates should be dry, clean and properly prepared, before any application of Polystick membranes commences. An approved substrate technical bulletin can be furnished upon request. It is recommended to refer to applicable building codes prior to installation to verify acceptable substrates. 12. The Polyglass Miami -Dade Notice of Acceptance (NOA) approval for Polystick membranes and PolyProtector UDL can be furnished upon request by our Technical Services Department by calling 1 (800) 894 -4563. 13. Polyglass offers a 10 year Limited Material Warranty on all properly installed Polystick self - adhered underlayments. Warranty must be requested and registered by Polyglass to be in force. 14. Questions in regards to the application of Polyglass products should be directed to our Technical Services Department at 1 (800) 894 -4563. 15. Polyglass recommends that applicators follow good roofmg practices and applicable procedures as outlined by the National Roofmg Contractors Association (NRCA). PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING LEVIITATIONS OF SPECIFIC APPLICATIONS. LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS AND RECOMMENDATIONS. END OF THIS ACCEPTANCE NOA No.: 09- 0806.07 Expiration Date: 09/13/11 Approval Date: 03/31/10 Page 6 of 6