RF-11-191F Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Inspection Number: INSP - 155665 Permit Number: RF -2 -11 -191 Scheduled Inspection Date: June 06, 2011 Inspector: Bruhn, Norman Owner: Job Address: 429 NE 102 Street Miami Shores, FL 33138- Project: <NONE> Contractor: CLIMAX ROOFING INC Permit Type: Roof Inspection Type: Final Roof Work Classification: Flat Phone Number Parcel Number 1132060170790 Phone: (786)413 -4695 Building Department Comments RE -ROOF BACK FLAT SECTION Passed -() Failed Correction Needed Re- Inspection Fee No Additional Inspections can be scheduled until re- inspection fee is paid. Inspector Comments i'c__ June 03, 2011 For Inspections please call: (305)762 -4949 Page 5 of 26 ACORD. CERTIFICATE OF LIABILITY INSURANCE CERTIFICATE NO,1 DATE 4AC11- 9100462 - 993035 PRODUCER Eighpoint Risk Services LIZ 14160 Dallas Parkway 9500 Dallas, TX 75254 (900) 632 -5096 (972) 715 -0959 Pax: (972) 404 -4450 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AMEND, EXTEND OR ALTFR THF COVFRAGF AFFORDFO BY THF POLICIES BELOW INSURERS S AFFORDING COVERAGE INSURED: Aspen Staff Leasing, Inc. 1 /c /f: CLINAX ROOFING, INC 1557 60 *_h SOUTH MIAMI, FL 33165 (786) 413 -4695 Fax: (305) 485 -4599 INSURERk Companion Propp.rty and Casualty insuramao C INSURER B: INSURER C INSURER D: INSURER E: COVERAGES THE POLICIES OF INSURANCE LISTED BELOW NAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT. TERM OR CONDIISON OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POUCIES DESCRIBED HEREIN 13 SUBJECT TO ALL THE TERMS. EXCLLSIONS AND CONDITIONS OF SUCH POLICIES. AGGREGATE UMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. IASR TYPE OF INSURANCE POLICY NUMBER POLICY EFFECTIVE . i, } ; . � PO CY E MKRA 2 k- .. � �∎ � • • LIMITS GENERAL LIABILITY COMMERCIAL GENERAL UAEIJTY EACH OCCURRENCE S FIRE DAMAGE (Arty One Flre) $ MED EXP (Any arts miserly $ ■. CLAIMS MADE EJ OCCUR PERSONAL & ADV INJURY $ ■ GENERAL AGGREGATE $ ■ PRODUCTS - COMP/OP AGG 5 GEN'L AGGREGATE OMIT APPLIES PER: POLICY n P'$9 n Loc AUTOMOBILE ■ ■ ■ ■ ■ ■ ■ LIABILITY ANY AUTO AU. OWNED AUTOS SCHEDULED AUTOS HIRED AUTOS NON- CIWNED AUTOS COSIBINED SINGLE UM'T MA ewe) s BODILY INJURY (Per person) $ BODILY INURY (Per eccdentl $ PROPERTY DAMAGE (Per =Item) 5 GARAGE LIABILITY ANY AUTO AUTO O N L Y - EA ACCIDENT S OTHER THAN EA ACC $ AUTO ONLY AGG $ EXCESS ■ UABIUTY EACH OCCURRENCE S AGGREGATE $ OCCUR CLAMS MADE $ $ . DEDUCTIBLE RETENTION $ 8 A WORItERSCOMFENSARONAND EMPLOYERS LJABILITY WC362727400 04/01/2011 04/01/2012 x irAretd Pa- 8 1000000 EL. EACH ACCsoENT EL DISEASE -EA EMPLOYEE S 1000000 EL.DISEASE- POUCYUMIT $ 1000000 OTHER ■ LIMITS $ UMrTS S u- 1. Staff wages leased ***PLEASE This (HAN Ur UrGUA IIUN.-YLU.M UI rib, certificate remains Leasing, Inc.. Coverage to Aspen Staff Leasing, ROOFING, SEE ATTACHED PLOYEEROSTER 14Lty t7 L.t.0 fNb ••' .• _ •• in effect, provided the client's is not provided for any Inc.. Applies to 100% effective 04/01/2011. * w account employee for of the employees is in good standing with Aspen which the client is not reporting of Aspen Staff Leasing, Inc. CERTIFICATE HOLDER 1 1 ADDYRONAL INSURED; INSURER LETTER: MIAMI SHORES 10050 NE 2ND AVE MIAMI SHORES, FL 33133 CANCELLATION SHUULU ANY UP IHt AUOVe D!.bLNItIk13 WJLILIr&bh CANCI: ED 11W-UNt. I tit t1WINAtILUN DATE THEREOF. THE ISSUING INSURER WILL ENDEAVOR TO MAIL 30 DAYS WRITTEN NOTICE TO THE CERTIFICATE HOLDER NAMED TO THE LEFT, BUT FAILURE TO DO SO SHALL IMPOSE NO Oi .IGATION OR LIABILITY OF ANY KIND UPON THE INSURER, ITS AGENTS OR REPRESENTATIVES. AUTHORIZED REPRESENTATIVE ACORD 25-5 (7197) ACORD CORPORATION 1988 Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 INSPECTION'S PHONE NUMBER: (305) 762.4949 BUILDING PERMIT APPLICATION FBC 20 MAR el 0 011 BY: - - - — ®_® Permit No. pr z- I - of f Master Permit No. Permit Type: BUILDING ROOFING OWNER: Name (Fee Simple Titleholder): ( -A Z ›7 F Nc- ° Phone#: Address: liZ 6% /vi /L Z $ City: I1 Tf1Mi S Il U S State: (L Tenant/Lessee Name: Phone#: Zip: 33 13 Email: JOB ADDRESS: (1Z q !J - 101 5i City: Miami Shores County: ��- Miami Dade Zip: 3 3 1 3 g Folio/Parcel #: /% 3 z.e 6 017 0 1 q10 Is the Building Historically Designated: Yes NO X Flood Zone: CONTRACTOR: Company Name: C (IPA- l u stf ; 7N Address: l V3 S 1 i 91 4 VE City: /t/f : 4-N/; State: f-1- Qualifier Name: T-01,' 6 f3A-m *TA A, Phone#: 144 4(3 - (405 Zip: 33/6 S' Phone#: 5A-A4.6 State Certification or Registration #: C Ce / 3 Z- KZ 3 Certificate of Com Contact Phone#: 7 O t L//2 - '/6y s Email Address: DESIGNER: Architect/Engineer: IJ Value of Work for this Permit: $ 1�I 6110c, 0 Square/Linear Footage of Work: Z 4,7 Type of Work: ❑Addition NJAlteration ❑New ORepair/Replace ODemolition Description of Work: I l — 1200 C lk"r 1 12E—V V S 0 PA- a D) Nrq � P * *' ** * ** * * * ** * * **d' ** ** * * ***** * e ** *F Submittal Fee $ Permit F ee Scanning Fee $ Radon Fee $ Notary $ Train, ducation Fee $ Double Fee $ Structural Review $ CCF $ CO /CC $ DBPR $ Bond $ Technology Fee $ TOTAL FEE NOW DUE $ (. 00 4 Bonding Company's Name (if applicable) Bonding Company's Address �\ City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address 114 City State l\' Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for FT.F?CTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature ;° ' i`/ Signature Owner or Agent Contractor The foregoing instrument was acknowledged before me this n The foregoing m trument was acknowledged before me this ZIS day of '144 , 20 11 , by , day of l'Atk , 20 0- , by who is perso own to me or who has produced who i rsonalto me or who has produced As identification and who did take an oath. as identification and who did take an oath. NOTARY PUBLIC: APPROVED BY NOTARY PUBLIC: x,.1°'7/ Plans Examiner Zoning Structural Review (Revised 07 /10 /07)(Revised 06 /10/2009)(Revised 3/15/09) Clerk Cming MrMI Comte Huck Mlaml -D °. "'" = uil • ing ' epartment Electronic Application High Velocity Hurricane Zone Roofing Permit Application Form 'Delivering Excellence Every Day Illustrate Components Noted and Details as Applicable: Woodblocking, Gutter, Edge Terminations /Stripping /Flashing, Continuous Cleat, Cant Strip, Base Flashing, Counterflashing, Coping, Etc. Indicate: Mean Roof Height, Parapet Height, Height of Base Flashing, Component Material, Material Thickness, Fastener Type, Fastener Spacing Or: Submit Manufacturers Details that Comply with RAS -111 and Chapter 16. PaTgWah hv7AR302011 gy „,..e2A,....o„ COPING METAL WJ CON 1 CLEAT 1 WAGE HEAVIER PT WOOD BLOCKING — SCREW W/ SEALING WASHER a A 4 4 4 4 e R 4 4 TOP PLY Co • e a r - 1.. Pk. 111111114011111111111111 111 ARSE FLASHING INTERPLES BASE SHEET • t \ ti \ ti e e —CANT STRIP '` -TOP LAYER INSULATION \ `BASE LAYER INSULATION \ CONCRETE DECK ASTM PRIIUWR 1/4' ANCHOR SHEET Miami Shores APPROVED ZONING DEPT BLDG DEPT BY Village DATE SUBJECT TO COMPLIANCE WITH ALL FEDERAL STATE AND COUNTY RULES AND REGULATIONS Parapet wall height: Roof Mean Height: Coping Metal: �-- ['4k • 4'` VACS _ 24�i4 Cleat; [Cotir l iv)D S L2 Wood Nailer: Wood Nailer Fastening: Base Flashing: Base Sheet: Top Layer of insulation: Base Layer of Insulation: Anchor Sheet: 1 1 1• Florida Buiiding� ode Edition : High Velodty Hurr aim Zonevnif m Peimit Apeman Form. Section C (Low Moped. loped Roof System) Fill in Specific Roof Assembly Components and Identify M.anhfactitrer (If a components not used, WO* as• "NAB . • System Manufacturer: G .Ac - �p � NOA Noy 7'"' 1 t i/ �► r 9 Deaign Wlnd Pik, From RAS 128 oar Gal an: • Pmaxi•- .' Rama:. -- $2-Pry: -' 124 • Max. Design Pre e: From t e Specific NOA • System: - —42 -.5 ••'tType: GaugeiThickness slg Anchor/Base Sheet & No: of PPy(s):6idN Q.h SS BASE Street Fasteng 'Material': • .• t . iMit tVirrisi hu:tdation Base Layer.. . • .M /is: •Base',mutationst* and.Thic ess• Ali /A • • Base-insulation r-a ei/Bo gate: AY A.• • Top Ind . A/ l iA • . • Top fnscdai iOn•Size and Thidaiess; • tv /A Top Iniulation Festener/HorrdIM krg•ai eriii:. • A914 • . aase Sheets) b ■k). of PIA. s): . NIA Base Sheet FastenebBohding Mdberiel= _ • • Pry Sheet(s) $ No. of Plytssi ; Ps �a la g Top •Ply:. • Top Ply Fastener' Surfacing: ' IVMi • Fastener_Spacing for Anciior/Base Sheet- Attachment - . Rekt ace .# z @ - 7 oc Perhneter:. _' oc ® Lap. #Rows ' • -•oc Comte:' ' oo ft LaP. # Rows (o @ "°C• • Number. of Fasteners Per Insulation • BOard • WA. - Field _ • Perhneter Comer.___, • .Ujustrap Components Noted and ffemifs atrnAcppncat�r._ : = woodblocrcing, Gutter. Edge 7' •Terrimrrueion, .5, FJShing. cantons •cleat Cant' : Snip,: 6a$e- Counter- Fiashti�. • • "Auk: Mean :Roof ;:Height, Parapet Height.- Height of Base hing,' Compar!ent= Matmlat.' - Material Thk:lcness, Fastener tom, Fastener Spacing 'tor Subunit- Maniifacturers •Details :tat Comply with RAS 1.11 and chapter 16.:. - •• Di -' a S�KCO• bN�No�.:$ "dLs Astrvim� e ••1 A■ ( Miami Shores Village Building Department 90050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 INSPECTION'S PHONE NUMBER: (305) 762.4949 BUILDING PERMIT APPLICATION FBC 20 EB 0 211 BY: Permit No. + 1 t S f Master Permit No. Permit Type: BUILDING ROOFING DM /NY REISS) G OWNER: Name (Fee Simple Titleholder): f�,4L FcgA/y INC. Phone#: 306 4S8 - 7134 ¥{ZRivi /0Z 5i City: /44M% j Slott 'f i I h4Gf State: Ft Zip: 3313% Tenant/Lessee Name: Phone#: Email: Address: JOB ADDRESS: fz R nie. 10 2 ST City: Miami Shores County: Miami Dade zip: 33138 Folio/Parcel #: 11 - 320 -011- 07T O Is the Building Historically Designated: Yes NO X Flood Zone: CONTRACTOR: Company Name: Crit/44-X goo F1N6 .L N C Phone#: 7 d 6p 113444'5 Address: / S.3 / SW 9s1 AVE City: 1^4 TOM i State: Ft- Zip: 33) t2 5 Qualifier Name: 17Tb t O tai'SAir A rig • Phone#: 7,6 413 - Li 1AS State Certification or Registration #: CCC 132 gs g23 Certificate of Competent #: Contact Phone#: 77S(0 q13 - 4 (i' 5 Email Address: &/1-5A-4741-01; (41)1A-400 DESIGNER: Architect/Engineer: l 1/j4 Phone#: Value of Work for this Permit: $ 2 300.04 Square/Linear Footage of Work 217 Type of Work: DAddition Alteration ONew ORepair/Replace ODemolition Description of Work RE- pooF FLAT sic oN) "i pt1 Submittal Fee $ Permit Fee $ 6),5 CCF $ CO /CC $ Scanning Fee $ Radon Fee $ DBPR $ Bond $ Notary $ Training/Education Fee $ Technology Fee $ Double Fee $ Structural Review $ TOTAL FEE NOW DUE $ Bonding Company's Name (if applicable) Bonding Company's Address , j City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: 1 certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Owner or Agent The foregoing instrument was acknowledged before me this 3 day of r-i lo , 20 1 l , by Signature `l o Ct' Contractor The foregoing trument was acknowledged before me this d a y o f P L . ,20 (l ,by who is personally known to me or who has produced who is personally known to me or who has produced as identification and who did take an oath. NOTARY PUBLIC: As identification and who did take an oath. NOTARY PUBLIC: APPROVED BY 9/96J-7.7 Plans Examiner Zoning Structural Review (Revised 07!10 /07)(Revised 06 /10i2009)(Revised 3/15/09) Clerk ROOF ASSEMBLIES AND ROOFTOP STRUCTURES \!..; tt FEB o 4 2011 j' BY: Florida Building Code Edit High-Velocity Hurricane Zone Uniform Permit Miami Shores Village APPROVED BY DATE 70NING DEPT r"r:PT on 2007 Applicilli ()1,1k i Cv1/80 ..11,t( ,A!,1 IANCF WITH Al AND 131 L FFDFFIAL GI ji Ai IoNs &action A (GenPral Information) 12'ct - (ct Master Permit No. Process No. Contractor's Name 0LkuLciaa16a rNC Job Address 41Z gi NE / /5 Low Slope 0 Asphaltic Shingles ROOF CATEGORY O Mechanically Fastened Tile O Metal Panel/Shingles 0 Prescriptive BUR-RAS 150 ROOF TYPE 0 New Roof afReroofing 0 Recovering ROOF SYSTEM INFORMATION Low Slope Roof Area (SF) Steep Sloped Roof Area (SF) O Mortar/Adhesive Set Tile O Wood Shingles/Shakes 0 Repair 1=1 Maintenance Total (SF) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. a FLORIDA BUILDING CODE — BUILDING t Miami-Shores Village Building Department 10050 N.E.2nd Averkte - Miami Shores,Tiorida.3-3138 Tel: (305)7952204 Fax: (305) 756.8972 OWNERS1 AFFIDAVIT OF EXEMPTION ROOF TO WALLCOINECTION HURRICANE IIITIGATION_RETROFff FOR EXISTING SITE - - BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES PERSUANT TO-SECTION 5a11.844 F.S. To: Miami Shores Village Buffcrmg Department 10050 NE 2fid Ave Miami Shores, A 33138 Re: Owner's Name: &Ai- &/-005 Dooffry Pe) • Property Address: IP /lig /0z- or. Roofing Permit Number. Dear Buililing Officiat 1 bA IA y Prips certify that 1 am not required to lac& the roof to wan connections of my buffing because: reAL Fivarri Date: 2-3' - 1 I iThe just valuation for the sbucture for pupose of ad valorem taxation is less than $300,000200. Please attach proof of ad valorem taxation. O The building was constructs in compffance with the provisionsof the FloridaBOilding Ccde (FBC) or with the provisions of 1994 griffon of the South Florida Building Code (1994 SFBC) State of Florida County of Dade •• The undersigned being the &daily sworkdepcdes and says that he/she is the owner for the above property mentioned. Swom to aml subscribed before me this 3 *of ra-4 Zoir Wel Print Name Notary Public, Sate of Florida at Large .6444A t,r4,,a 14 equEd born= than =DAM% middle WEIN was notconsfactedwili FIX nor a IMIN ePPEctlan flom a Gentzttal Conttactorfor the Recite MI =tacks' Hokin hOgairon. SFBC. Then you must pm*: a o RE: Permit # 1 :I (it( KilSAati iR. (Print name and circle License Type) Miami Shores Viiiage Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 DATE: Z — 3 " INSPECTION AFFIDAVIT cgooTto& CON7a• J licensed as a (n) Contractor / Engineer / Architect, FS 468 Building Inspector License #: CC's 132 SS$ 23 On or about Z'S-t ,1 did personally inspect the roof deck nailing and (Date & time) Secondary water barrier work at 9'2'Y it/F /02_ ST (Complete Job Site Address) Based upon that examination I have determined the installation was done according to the Hurricane Mitigation Retrofit Manual (Based on 553.844 F.S) State of Florida County of Dade: 4.L The undersigned, being the first duly swom, deposes and says that he /she is the contractor for the above property mentioned. Swom to and subscribed before me this 3 •f _... 20 Notary Public, Sate of Florida at Large 'General, Building, Residential, or Roofing Contractors or any individual certified under 468 F.S. to make such an inspection. Include photographs of each plane of the roof with permit # and address # clearly shown marked on the deck for each inspection Revised on 5/21/2009 1 Florida Bulldog Code &Rion 2007 High Velocity Hurricarm Zone Uniform PerndtAmdication Fonn Section C (Low Sloped Roof System), F® In Specific Roof Assembly Comnpommte and Identify Manufact ner -• (6a component l not used, ►as`W J System Gq. l pi* e'T . ®7- lam. Oct NOAP4o.: Design Wind Pressures, From RAS 126 or Pausal .2 .PmariSS Pa 'ag( '3 Max Destim Pressure, tra. t4,81epelo NOA Dedc if wis 1 A4 Slopix f 2-17 - Sheet &No ofPiy(s) 44 AndrodBase She FaenedBonding Mated* hoadadon Baselay= 44 Base-Insulation Size and T Bala insidation FastenenBonding Welk* Top insttharn Layer: 11 Top hit Size and l NIA Top Insulatkm FrodenedBonding Pitatelat 41� BaseSheel(s) & No. of Ply(s'• CI I- 8 Sit 1' 1114 rs. fran erffirge DIM i Ply S h s) & No. of Ply* }} t o 1) PIyS Fr r4W q. t" Top Ply I PI y IF Mhder4 at Alger T W �f l" O P is '� 4-1 !v suiradnfr Cmits UtL$ LS Fastener Snack* for Sheet Attachment .'oe Lag #Ross Z g 'oc • @LW. # Rowel. @. i0 'oc 4 -cc@ Lap, #Rowel_ @ ±"oc Number of Fasbnons Per Insutation k P +C�r N14- I Wustrats Comte Noted and - t. Edge Tom, SMpp6tg, Flashing, Conlinnmts3 Cleat, Cant Strip, Base Fes, Counter- Flashing, Coping, E Mean Roof Height, Parapet Height, Height of Base Flashing, Component Material, Mattel Ttdckness, Fastener Type, Fastener Spacing or Submit Nkinufactimns Details that Comply ear RAS 111 and Chapter 16. Il KItiotsitt. Suracg IM►3 gliksownruf tolvar ( Oho, boor o15 a,/R .. NMLS / FT. NIA t06ar tYk Pee ,tee 14 3j Rs tte A`6o FT.- Parapet Heinht ION Mean Roof MIA 123 01-48 12/09 Pia BUILDING CODE COMPLIANCE OFFICE (BCCO) PRODUCT CONTROL DIVISION NOTICE OF ACCEPTANCE (NOA) GAF Materrial Corporation. 1361 Alps Road Wayne, NJ 07470 MIAMI -DADE COUNTY, FLORIDA METRO -DADE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 MIAMI, FLORIDA 33130 -1563 (305) 375 -2901 FAX (305) 375 -2908 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by the BCCO and accepted by the Building Code and Product Review Committee to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Division that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code and the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: GAF Conventional Built-Up Roof System for Wood Decks. LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews and revises NOA No. 03- 0501.05 and consists of pages 1 throygh 19. The submitted documentation was reviewed by Jorge L. Acebo. (!) NOA No.: 07- 1219.09 Expiration Date: 11/04/13 Approval Date: 03/20/08 Page 1 of 19 ROOFING SYSTEM APPROVAL Category: Sub - Category: Deck Type: Maximum Design Pressure Roofing BUR Wood -75 psf TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Test Product Dimensions Specification Leak BusterTM MatrixTM 307 Premium Asphalt Primer GAF Mineral ShieldTM Granules Leak BusterTM MatrixTM 305 Fibered Asphalt Emulsion Leak BusterTM Matrix TM 303 Premium Fibered Aluminum Roof Coating LeakBusterTM MatrixTM • 322 Elastomeric Roof Coating LeakBusterTM MatrixTM Select Asphalt Emulsion Fibered 306 Leak BusterTM MatrixTM 204 Wet/Dry Roof Cement RUBEROID® Modified Bitumen Flashing Cement LeakBusterTM MatrixTM 201 Premium SBS Flashing Cement GAFGLAS® #75 3, 5, 55 gallons 60 & 100 lb. bags 5 gallons 1, 5 gallons 55 gallons 55 gallons 1, 5 gallons 5 gallons 5 gallons ASTM D41 ASTM D 1863 ASTM 1227 Product Description Asphalt concrete primer used to promote adhesion of asphalt in built -up roofing. Granules for surfacing of exposed asphalt, cold process cement or emulsion. GAF Mineral ShieldTM Granules shall be used for flashing applications only. Surface coating for smooth surfaced roofs. ASTM D 2824 Fibered aluminum coating. Elastomeric roof coating. Asphalt emulsion fibered. ASTM D -4586 Refined asphalt blended with a mineral ASTM D -3409 stabilizer and fibers. Permits adhesion to wet and dry surfaces. ASTM D 4586 Fiber reinforced, polymer modified Flashing cement ASTM D 4586 Asphalt flashing Cement 39.37" (1 meter) ASTM D 4601 Asphalt impregnated and coated glass mat wide base sheet. NOA No.: 07- 1219.09 Expiration Date: 11/04/13 Approval Date: 03/20/08 Page 2 of 19 Product GAFGLAS® 1180 ULTIMATA' Base Sheet GAFGLAS® Flex PIyTM 6 GAFGLAS® Ply 4 GAFGLAS® Mineral Surfaced Cap Sheet GAFGLAS® EnergyCapTM Mineral Surfaced Cap Sheet GAFGLAS® STRATAVENT® EliminatorTM Perforated GAFGLAS® Flashing GAFGLAS® STRATAVENT® EliminatorTM Nailable RUBEROID® SBS Heat We1dTM Smooth RUBEROID ® SBS Heat- WeIdTM Granule RUBEROID® SBS Heat- We1dTM 170 FR RUBERO]D® SBS HeatWeldTM PLUS RUBEROID® SBS Heat- We1dT"" PLUS FR RUBEROID® SBS Heat We1dTM 25 RUBEROID® Modified Base Sheet '.111Z 4 APPROVEDI Dimensions 3937" (1 meter) wide 39.37" (1 meter) wide 39.37" (1 meter) wide 39,37" (1 meter) wide 3937" (1 meter) wide 39.37" (1 meter) wide Various 39.37" (1 meter) wide 1 meter (39.37 ") wide 1 meter (39.37 ") wide 1 meter (39.37") wide 1 meter (39.37 ") wide 1 meter (3937") wide 1 meter (3937") wide 39.37" (1 meter) wide Test Specification ASTM D4601 ASTM D 2178 ASTM D 2178 ASTM D 3909 ASTM D 3909 ASTM D 4897 D 3672 ASTM D 4897 D 3672 • ASTM D -6164 ASTM D -6164 ASTM D -6164 ASTM D -6164 ASTM D-6164 ASTM D -6164 ASTM D4601, Type II, UL Type G2 BUR Product Description Asphalt impregnated and coated, fiberglass base sheet Type VI asphalt impregnated glass felt with asphalt coating. Type IV asphalt impregnated glass felt with asphalt coating. Asphalt coated, glass fiber mat cap sheet surfaced with mineral granules. Asphalt coated, glass fiber mat cap sheet surfaced with mineral granules with factory applied layer of TOPCOAT®EnergyCoteTM. Fiberglass base sheet impregnated and coated on both sides with asphalt. Surfaced on the bottom side with mineral granules embedded in asphaltic coating with factory perforations. Asphalt coated glass fiber mat flashing sheet available in three sizes. Fiberglass base sheet impregnated and coated on both sides with asphalt. Surfaced on the bottom side with mineral granules embedded in asphaltic coating. Non -Woven Polyester mat coated with polymer - modified asphalt and smooth surfaced. Non -Woven Polyester mat coated with polymer modified asphalt and surfaced with mineral granules. Non -Woven Polyester mat coated with fire retardant polymer modified asphalt and surfaced with mineral granules. Non -Woven Polyester mat coated with . polymer modified asphalt and surfaced with mineral granules. Non -Woven Polyester mat coated with fire retardant polymer modified asphalt and surfaced with mineral granules. Non -Woven Polyester mat coated with polymer - modified asphalt and smooth surfaced. Premium glass fiber reinforced SBS modified base sheet NOA No.: 07- 1219.09 Expiration Date: 11/04/13 Approval Date: 03/20/08 Page 3 of 19 Product RUBEROID® 20 RUBEROID® Mop Granule RUBEROID® Mop Plus (Granule) RUBEROID® MOP Smooth RUBEROID® MOP 170FR RUBEROID® MOP FR RUBEROID® TORCH Smooth RUBEROID® TORCH Granule RUBEROID® TORCH PLUS (Granule) RUBEROID ® TORCH FR RUBEROID® 170FR TORCH RUBEROID® 30 RUBEROID® 30 FR RUBEROID® ULTRACLAD® RUBEROID® Dual FR Vent Stacks (metal and plastic) Dimensions 39.37" (1 meter) wide 3937" (1 meter) wide 39.37" (1 meter) wide 39.37" (1 meter) wide 3937" (1 meter) wide 39.37" (1 meter) wide 39.37" (1 meter) wide 39.37" (1 meter) wide 39.37" (1 meter) wide 39.37" (I meter) wide 39.37" (1 meter) Wide 39.37" (I meter) wide 39.37" (1 meter) wide 3937" (1 meter) wide 3937" (1 meter) Wide Test 5pecification ASTM 13 6163 ASTM D 5147 ASTM D 6222 ASTM D 5147 ASTM D 6222 ASTM D 5147 ASTM D 6164 ASTM D 5147 ASTM D 6164 ASTM D 5147 ASTM D 6164 ASTM D 5147 ASTM D 5147 ASTM D 5147 ASTM D 6222 ASTM D 5147 ASTM D 6222 ASTM D 5147 ASTM D 6222 ASTM D 5147 ASTM D 6163 ASTM D 5147 ASTM D 6163 ASTM D5147 ASTM D 6298 ASTM D 5147 ASTM D 6164 ASTM D 5147 TAS 100(A) ASTM D 1929 ASTM D 635 Product Description SBS modified asphalt base sheet and interply sheet reinforce with a glass fiber mat. Non -woven polyester mat coated with polymer modified asphalt and surfaced with mineral granules. Non -woven polyester mat coated with polymer modified asphalt and surfaced with mineral granules. Non -woven polyester mat coated with polymer- modified asphalt and smooth surfaced. Non -Woven polyester mat coated with fire retardant polymer modified asphalt and surfaced with mineral granules. Non -Woven polyester mat coated with fire retardant polymer modified asphalt and surfaced with mineral granule's. Heavy duty, polyester reinforced, asphalt modified bitumen membrane, smooth surface. Asphalt impregnated, coated felt, surfaced with mineral granule. Heavy duty, polyester reinforced, asphalt modified bitumen membrane, granule surface. Heavy duty, polyester reinforced, coated with fire retardant asphalt modified bitumen membrane, granule surface. Heavy duty, polyester reinforced, coated with fire retardant asphalt modified bitumen membrane, granule surface. Non -woven fiberglass mat coated with polymer modified asphalt and surfaced with mineral granules. Non -woven fiberglass mat coated with fire retardant polymer modified asphalt and surfaced with mineral granules. Woven fiberglass mat coated with Polymer modified asphalt and surfaced with aluminum, copper or stainless steel foil. Non -woven polyester and fiberglass mat coated with file retardant, polymer modified asphalt and surfaced with mineral granules. One way valve vent used to relieve built -up pressure within the roof system. GAF Vent Stacks are available in metal or plastic. NOA No.: 07- 1219.09 Expiration Date: 11/04/13 Approval Date: 03/20/08 Page 4 of 19 Product Leak Buster"' MatrixTM 302 Non Fibered Aluminum Roof Coating GAF Built -Up Roofing Asphalt RUBEROID® MOD Asphalt, Asphalt L & Asphalt P Leak Buster"' MatrixTM 602 Leak Buster", Matrix"' 715 LeakBusterTM Matrix", 531 WeatherCotem SeamCoteTM FireOut"M VersaShield® VersaShield® FB-1S VersaShield® FB-2S TOPCOAT® FireShield® MB Leak Buster"' MatrixTM 201 SBS Flashing Cement Leak Buster"' MatrixTM 102 SBS Adhesive Leak Buster"' Matrix'' 202 SBS Flashing Cement Leak Buster"' MatrixTM 203 Plastic Roof Cement Leak BusterT' Matrix", 103 Cold Process Adhesive Dimensions 5 gallons 100 lb. cartons, bulk 601b. kegs 5 gallons 5 gallons 2 gallons 2, 5 gallons 5, 55 gallons 350 so ft. roll 350sg ft. roll 350 sq ft. roll 5, 55 gallons 5 gallons 5 gallons 5 gallons 5 gallons 5 gallons Test Specification Product Description ASTM D2824, Non-fibered aluminum pigmented, asphalt Type 1 roof coating. ASTM D312, Types I, II, III and IV proprietary ASTM D -412 ASTM D -21 -96 ASTM D1475 ASTM E -1644 ASTM D3019 ASTM D3019 ASTM D4586 ASTM D4586 ASTM D3019 Interply mopping and surfacing asphalt. SEBS modified asphalt. Surface coating for smooth surfaced and mineral surfaced roofs. Surface coating for smooth surfaced and mineral surfaced roofs. Surface coating for smooth surfaced and mineral surfaced roofs. Elastomeric roofing membrane. Low VOC, fire barrier coating. Non - Asphaltic Fiberglass -Based Underlayment. Non - Asphaltic Fiberglass -Based Underlayment. Non - Asphaltic Fiberglass -Based Underlayment. Elastomeric roofing membrane Cold Applied Modified SEBS Asphalt Adhesive — Flashing Grade. Cold Applied Modified SEBS Asphalt Adhesive. Cold Applied Modified SEBS Asphalt Adhesive — Flashing Grade. Standard Plastic Asphalt Roofing Cement Cold Applied Asphalt Adhesive. NOA No.: 07- 1219.09 Expiration Date: 11/04/13 Approval Date: 03/20/08 Page 5 of 19 Product Leak BusterTM MatrixTM 303 Fibered Aluminum Roof Coating Leak BusterTM MatrixTM 304 Non Fibered Aluminum Roof Coating Dimensions 5 gallons 5 gallons APPROVED INSULATIONS: Product Name EnergyGuardTM RA, RN Composite A & N EnergyGuatdm Fiberboard EnergyGuardTM Permalite EnergyGuardTM GAFCANTTM EnergyGuardTM Permalite Recover Board EnergyGuardTM Tapered Edge Strip EnergyGuardTM Perlite EnergyGuardTM High Density Fiberboard EnergyGuardTM Composite EnergyGuardTM' Composite RA Wood Fiber High Density Wood Fiberboard Perlite Insulation Dens Deck', Dens Deck® Prime, Dens Deck® Dura GuardTM Structodek SecurockTM Test Specification ASTM D 2824 Product Description Fibered aluminum coating. ASTM D2824, Non- Fbered aluminum pigmented, asphalt Type I roof coating. Table 2 Product Description: Polyisocyanurate foam insulation Polyisocyanurate foam insulation with high density fiberboard or Permalite perlite insulation. Fiberboard insulation. Perlite insulation board. Cut perlite board Perlite recover board Tapered perlite board Perlite insulation board High density wood fiberboard insulation. Polyisocyanurate /wood fiberboard composite Polyisocyanurate /wood fiberboard composite Wood fiber insulation board Wood fiber insulation board Perlite insulation board Water resistant gypsum board Wood fiber insulation board Fiber reinforced roof board Manufacturer (With Current NOA) BMCA ' GAF Materials Corp. GAF Materials Corp. GAF Materials Corp. GAF Materials Corp. GAF Materials Corp. GAF Materials Corp. GAF Materials Corp. GAF Materials Corp. BMCA BMCA generic generic generic G -P Gypsum Corp Knight Celotex UM Corporation NOA No.: 07- 1219.09 Expiration Date: 11/04/13 Approval Date: 03/20/08 Page 6 of 19 APPROVED FASTENERS: Fastener Product Number Name 1. Drill Teem #12 Standard, #14 and #15 extra. Heavy Duty Fastener , Heavy Duty Roofing Fastener 2. Drill-Teem ASAP 3. Drill -Teem #12 or #14 Standard screws with AccuTrac Plate 4. Drill -TecTM Galvalume Plates 5. Drill-Teem Polypropylene Plates 6. Drill-Teem' AccuTrac Plate EVIDENCE SUBMITTED: Test Aeencv Factory Mutual Research Corp. PRI Asphalt Technologies, Inc. IRT of S. Fl. TABLE 3 Product Description Insulation fastener and Base Play fastener for steel, wood & concrete decks. Pre - assembled Drill - TecTM Fasteners and metal and plastic plates. Base sheet fastening assembly. Round Gaivalume stress plates. Round polypropylene stress plates. Square Galvalume® coated steel plate. Test Identifier J.I. 2B8A4.AM J.I.3B9Q1:AM J.I. OD0A8.AM J.I. ODIA8.AM J.I.0Y9Q5.AM 3029832 GAF - 012 -02 -02 GAF -020 -02 -01 02-005 02 -014 Manufacturer Dimensions (With Current NOA) Various GAF Materials Corp. Various GAF Materials Corp. Various GAF Materials Corp. 3" and 3 W GAF Materials Corp. 3" and 3 %Z" GAF Materials Corp. 3" Square GAF Materials Corp. Description 4470 4470 4470 4470 -TAS 114 4470 -TAS 114 4470 - TAS 114 Physical Properties ASTM D 4977 TAS 114 TAS 114 Date 07.02.97 01.08.98 07.09.99 07.29.94 04.01.98 05.11.07 11.06.01 02.01.02 01.18.02 03.22.02 NOA No.: 07- 1219.09 Expiration Date: 11/04/13 Approval Date: 03/20/08 Page 7of 19 APPROVED ASSEMBLIES Deck Type 1I: Wood, Insulated • Deck Description: "' /32" or greater plywood or wood plank System Type A: Anchor sheet mechanically fastened, all layers of insulation adhered with approved asphalt. All General and System Limitations shall apply. One or more layers of any of the following insulations. . Insulation Layer (Table 2) Insulation Fasteners Fastener (When applicable: Steel plate only =S, plastic plate only (Table 3) Density /ft2 P). EnergyGuardTh , EnergyGuarifrm Composite, EverGuarrd® ISO, EnergyGuarddm RA, EnergyGuardTM RA Composite • Minimum 1" thick N/A N/A EnergyGuardTM High Density Wood Fiber, EnergyGuardTM Recover Board, Wood Fiber, • Minimum %2" thick EnergyGuardTM Perlite Minimum 3/4" thick Fiberglas (Min. `Si,b thick) N/A N/A N/A N/A N/A •N /A Note: MI insulation shall be adhered to the anchor sheet in full mopping of approved hot asphalt within the EVT range and at a rate of 20-40 lbs/100 ft2. Please refer to Roofing Application Standard RAS 117 for insulation attachment Insulation listed as base layer only shall be used only as base layers with a second layer of approved top layer insulation installed as the final membrane substrate. Composite insulation panels may be used as a top layer placed with the polyisocyanurate side facing down. GAF requires either a ply of GAFGLAS® STRATAVENT® Eliminatorh Perforated laid dry or a layer of EnergyGuardTM Perlite or wood fiber overlay board on all isoeyanurate applications. Fire Barrier: FireOutTM Fire Barrier Coating, VersaShield®NonAsphaltic Fiberglass -Based (optional) Underlayment or Securockh. Anchor sheet: GAFGLAS® #80 ULTIMATM Base Sheet, STRATAVENT® Eliminator"' Nailable, RUBEROID® Modified Base Sheet, RUBEROID® 20, RUBEROID Heat- We1dTM Smooth or RUBEROID® Heat- WeldT' 25 base sheet mechanically fastened as described below; Fastening Options: GAFGLAS® Ply 4, GAFGLAS® Flex PIyTM 6, GAFGLAS® #75 Base Sheet or any of above Anchor sheets attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" o.c. at the lap staggered and in two rows 12" o.c. in the field. (Maximum Design Pressure -45 psf,, See General Limitation #7) NOA No.: 07- 1219.09 Expiration Date: 11104/13 Approval Date: 03/20/08 Page 8 of 19 Fastening Options: GAFGLAS® Ply 4, GAFGLAS® Flex P1yTM 6, GAFGLAS® #75 Base Sheet or any of above Anchor sheets attached to deck with Drill -TecTM #12 standard, #14 or # 15 Screws and 3" Drill -TecTM steel plate or Drill -TecTM AccuTrac Plates, 12" o.c. in 3 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 12" o.c. in the field of the sheet. (Maximum Design Pressure -45 psf, See General Limitation #7) GAFGLAS® Flex P1yTM 6, GAFGLAS® #75 Base Sheet or any of above Anchor sheets attached to deck with approved annular ring shank nails and tin caps at a . fastener spacing of 9" o.c. at the 4" lap staggered and in two rows 9" o.c. in the field. (Maximum Design Pressure 52.5 psf, See General Limitation #7) GAFGLAS® #80ULTIMATM, RUBEROID®20, RUBEROID ®Mop Smooth, base sheet attached to deck with approved 1'/4" annular ring shank nails and inverted 3" steel plate at a fastener spacing of 9" o.c. at the 4" lap and in two rows - staggered with a fastener spacing of 9" o.c. in the center of the membrane. (Maximum Design Pressure -60 psf, See General Limitation #7j GAFGLAS® #75 Base Sheet or any of above Anchor sheets attached to deck with Drill -TecTM #12 standard, #14 or # 15 Screws and 3" Drill-TecTM steel plate or Drill -TecTM AccuTrac Plates, 12" o.c. in 4 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 9" o.c. in the field of the sheet (Maximum Design Pressure -60 psf, See General Limitation #7) Any of above Anchor sheets attached to deck approved annular ring shank nails and 3" inverted Drill -TecTM insulation plates at a fastener spacing of 9" o.c. at the 4" lap staggered in two rows 9" in the field. (Matdmum .Design Pressure -60 psf, See General Limitation #7) GAFGLAS® #75 Base Sheet or any of above Anchor sheets attached to deck with Drill -TecTM #12 standard, #14 or # 15 Screws and 3" Drill -TecTM steel plate or Drill -TecTM AccuTrac Plates, 8" o.c. in 4 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 9" o.c. in the field of the sheet. (Maximum Design Pressure -75 psf, See General Limitation #7) Base Sheet (Optional) Install one ply of GAFGLAS® #75, GAFGLAS® #80 ULTIMATM Base Sheet, GAFGLAS® STRATAVENT® EliminatorTM Perforated, RU BEROID® Modified Base Sheet, RUBEROID® Mop Smooth, RUBEROID® 20 RUBEROID® Heat- WeldTM Smooth or RUBEROID® Heat- WeIdTM directly over the top layer of insulation. Adhere with any approved mopping asphalt applied within the EVT range and at a rate of 20-40 lbs./sq; (see General Limitation #4). Ply Sheet One or more plies GAFGLAS® PLY 4, GAFGLAS® Flex P1yTM 6 sheet, #80 Ultima, RUBEROID® Mop Smooth or RUBEROID® 20 adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbssq. NOA No.: 07- 1219.09 Expiration Date: 11/04/13 Approval Date: 03/20/08 Page 9 of 19 Cap Sheet: (Optional) One ply of GAFGLAS "' Mineral Surfaced Cap Sheet or GAFGLAS®EnergyCapT' Mineral Surfaced Cap Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbsfsq. Surfacing: (Optional, required if RUBEROID® MOP Smooth or RUBEROID® 20 is top membrane) Install one of the following: 1. Gravel or slag applied at 400 lbs.sq. and 300 lbsJsq. respectively in a flood coat of approved asphalt at 60 lbs.sq. or applied in a flood coat of Leak Buster"( Matrix"' 103 Cold Process Adhesive applied at a rate of 3 gal./sq. 2. GAFGLAS® Mineral Surfaced Cap Sheet, GAFGLAS® Energy Cap Mineral Surfaced Capsheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20 -40 lbs.isq. 3. Leak Buster", Matrix", 303 Premium Fibered Aluminum Roof Coating. at 1.5 gal./sq. 4. Leak Buster' MatrixTM 715 , Leak Buster"( MatrixT' 322, TOPCOAT® MB +, TOPCOAT® Fireshield Elastomeric Roofing Membrane, applied at 1 to 1.5 gal. /sq. 5. Leak Buster"' MatrixTM 602 MB Xtra Elastomeric Roofing Membrane, EnergyCote® roof coating applied at 1 to 1.5 galisq. 6. TOPCOAT® Surface Seal, TOPCOAT® Fireshield® SB Solvent based Elastomeric Roofing Membrane applied at Ito 1.5 galisq 7. Advance Green Technologies Photovoltaic Laminate solar energy collector auxiliary roof equipment installed in compliance with manufacturer's specifications and applicable Building Codes. Maximum Design Pressure: See Fastening above. NOA No.: 07- 1219.09 Expiration Date: 11/04/13 Approval Date: 03/20/08 Page 10 of 19 ■ • :Deck Type 1I: Wood, Insulated Deck Description: 19/32" or greater plywood or wood plank System Type B: Optional base sheet laid dry; base layer of insulation mechanically fastened, optional top layer adhered with approved asphalt All General and System Limitations shall apply. One or more layers of any of the following insulations. Insulation for Base Layer (Table 2) When applicable: Steel plate only =S, plastic plate only =P EnergyGuardTM, EnergyGuardTM RA Minimum 13" thick EnergyGuardTM RN Minimum 1.4" thick 1, 2, or 3 Insulation Fasteners (Table 3) 1,2,or3 EnergyGuardTM Composite, EnergyGuardTM RA Composite Minimum 1.5 thick 3 EnergyGuardTM Perlite Minimum 3/4" thick EnergyGuardTM Fiberboard, EnergyGuardTM High Density Fiberboard Minimum 1" thick 1, 2, or 3 1 S(3.5 "), or 3 Fastener Density /ft2 1:3 ft2 1:3 ft2 1:3 ft2 1:2 ft2 1:4 ft2 Note: Base layer shall be mechanically attached with fasteners and density described. Insulation panels listed are minimum sizes and dimensions; if larger panels are used the number of fasteners per board shall be increased maintaining the same fastener density (See Roofing Application Standard RAS 117 for fastening details). GAF requires either a ply of GAFGLAS STRATAVENT® Eliminatorm perforated laid dry or a layer of EnergyGuardTM or wood fiber overlay board on all isocyanurate applications. Insulation for Top Layer (Table 2) Insulation Fasteners When applicable: Steel plate only =8, plastic plate only P (Table 3) Any of the insulations listed for Base Layer, above. N/A Fastener Density /ft2 N/A EnergyGuardTM High Density Wood Fiber, EnergyGuardTM High Density Wood Fiberboard, EnergyGuardrM Recover Board Minimum %2" thick N/A N/A Note: Optional top layer of insulation shall be adhered with approved asphalt within the EVT range and at a rate of 20 -401bs /100 ft2. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Composite insulation boards used as a top layer shall be installed with the polyisocyanurate face down. Fire Barrier: FireOutTM Fire Barrier Coating, VersaShieldeNon- Asphaltic Fiberglass -Based (optional) Underlayment or SecurockTM. NOA No.: 07- 1219.09 Expiration Date: 11 /04 /13 Approval Date: 03/20/08 Page 11 of 19 Base Sheets (Optional) Install one ply of GAFGLAS® #75, GAFGLAS® #80 ULTIMA' Base Sheet, GAFGLAS® PLY 4, GAFGLAS® Flex Ply= 6, GAFGLAS® STRATAVENT® Eliminator Perforated(laid dry), RUBEROID® Modified Base Sheet, RUBEROID® Mop Smooth or RUBEROID® 20 directly over the top layer of insulation. Adhere with any approved mopping asphalt applied within the EVT range and at a rate of 20-40 lbsJsq; (see General Limitation #4). Ply Sheet: Two or more plies of GAFGLAS® PLY 4, GAFGLAS® FlexPlyTM 6 ply sheet, #80 Ultima, RUBEROID® Mop Smooth or RUBEROID® 20 adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20 -40 lbs. /sq. (See specification number for appropriate number of plies). Cap Sheet: (Optional) One ply of GAFGLAS® Mineral Surfaced Cap Sheet or GAFGLAS® EnergyCapTM Mineral Surfaced Cap Sheet adhered in a full . mopping of approved asphalt applied within the EVT range and at a rate of 20 -40 lbs./sq. (See GAF application instructions for approved method of installation). Surfacing: (Optional, required if RUBEROID® MOP Smooth or RUBEROID® 20 is top membrane) Install one of the following: 1. Gravel or slag applied at 400lbssq. and 300lbs.sq. respectively in a flood coat of approved asphalt at 60 lbsJsq. or applied in a flood coat of Leak Buster", Matrix", 103 Cold Process Adhesive applied at a rate of 3 galfsq. 2. GAFGLAS® Mineral Surfaced Cap Sheet, GAFGLAS® Energy Cap Mineral Surfaced Capsheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20- 40lbs.sq. 3. Leak Buster", Matrix", 303 Premium Fibered Aluminum Roof Coating, at 1.5 gal./sq. 4. Leak Buster Matrix", 715 , Leak-Buster", Matrix", 322, TOPCOAT® MB +, TOPCOAT® Fireshield Elastomeric Roofing Membrane, applied at 1 to 1.5 gal /sq. 5. Leak BusterTM MatrixTM 602 MB Xtra Elastomeric Roofing Membrane, EnergyCote® roof coating applied at 1 to 1.5 gal. /sq. 6. TOPCOAT® Surface Seal, TOPCOAT® Fireshield® SB Solvent based Elastomeric Roofing Membrane applied at lto 1.5 galJsq 7. Advance Green Technologies Photovoltaic Laminate solar energy collector auxiliary roof equipment installed in compliance with manufacturer's specifications and applicable Building- Codes. Maximum Design Pressure: -45 psf; (See General Limitation #7) NOA No.: 07-1219.09 Expiration Date: 11/04/13 Approval Date: 03/20/08 Page 12 of 19 Deck Type 11: Deck Description: System Type C: Wood, Insulated 19/32" or greater plywood or wood plank One or more layers of insulation simultaneously attached; Base layer optional. All General and System Limitations shall apply. One or more layers of any of the following insulations. Insulation for Base Layer (Table 2) (When applicable: Steel plate only =S, platic plate only =P) EnergyGuardTM RN, EnergyGuardTM, EnergyGuardTM RA Minimum 1.3" thick Insulation Fasteners Fastener (Table 3) Density /ft2 N/A EnergyGnardTM Min. 1.4" thick N/A EnergyGuardTM Composite, EnergyGuarrdTM RA Composite Minimum 1.5" thick N/A EnergyGuardTM Perlite Minimum %" thick N/A Wood Fiber, EnergyGu ardTM Fiberboard, EnergyGuardTM High Density Fiberboard Minimum 1" thick N/A N/A N/A N/A • N/A N/A Note: All layers shall be simultaneously fastened; see top layer below for fasteners and density. Insulation panels listed are minimum sizes and dimensions; if larger panels are used, the number of fasteners shall be increased maintaining the same fastener density. Please refer to Roofing Application Standard RAS 117 ' for insulation attachment. GAF requires either a ply of GAFGLAS5 STRATAVENT® EliminatorTM perforated laid dry or a layer of EnergyGuardTM Perlite or wood fiber overlay board on all isoeyanurate applications. Insulation for Top Layer (Table 2) Insulation Fasteners Fastener When applicable: Steel plate only S, plastic plate only =P (Table 3) Density /ft2 EnergyGuard, EnergyGuard RA Minimum 1.3" thick EnergyGuardTM RN Minimum 1.4" thick EnergyGuardTM Composite, EnergyGuardTM RA Composite Minimum 1.5 thick EnergyGuardlM Perlite Minimum 3�4" thick Fiberglas Minimum "thick 1,2,or3 1,2,or3 3 1S(3.5 "), or 3 1,2,or3 Wood Fiber, EnergyGnardTM Fiberboard, EnergyGuardTM High Density Fiberboard Minimum 1" thick 1, 2, or 3 IAMI DADE • . APPROVED 1:3 ft2 1 :3ft2 1:3 ft2 1:2 ft2 1:2.67 ft2 1:4 ft2 NOA No.: 07- 1219.09 Expiration Date: 11/04/13 Approval Date: 03/20/08 Page 13 of 19 Note: Insulation panels listed are minimum sizes and dimensions; if larger panels are used, the number of fasteners shall be increased maintaining the same fastener density. Please refer to 'Roofing Application Standard RAS 117 for insulation attachment. GAF requires either a ply of GAFGLAS® STRATAVENT® Eliminator' Perforated laid dry or a layer of EnergyGuardTM Perlite or wood fiber overlay board on all isoeyanurate applications. Fire Barrier: FireOutTM Fire Barrier Coating, VersaShieieNon- Asphaltic Fiberglass -Based (optional) Underlayment or SecurockTM. Base Sheet: (Optional) Install one ply of GAFGLAS® #75, GAFGLAS® #80 ULTIMA' Base Sheet, GAFGLAS® PLY 4, GAFGLAS FIexPIy" 6, GAFGLAS® STRATAVENTT EliminatorTM Perforated (laid dry), RUBEROID® Modified Base Sheet, RUBEROID® Mop Smooth or RUBEROID® 20 directly over the top layer of insulation. Adhere with any approved mopping asphalt applied within the EVT range and at a rate of 20- 401bs. /sq.. If base sheet is applied-directly to polyisocyanurate insulation only a spot or strip mopped application as detailed in this approval the use of an overlay board is approved; see General Limitation #4. Ply Sheet: Two or more plies of GAFGLAS® PLY 4, GAFGLAS® FIexP1yTM 6 ply sheet, #80 ULTIMATM, , RUBEROID® Mop Smooth or RUBEROID® 20 adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20 -40 lbsfsq. Cap Sheet: (Optional) One ply of GAFGLAS® Mineral Surfaced Cap Sheet or GAFGLAS® EnergyCapTM Mineral Surfaced Cap Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20- 40lbs.sq. Surfacing: (Optional, required if RUBEROID® MOP Smooth or RUBEROID® 20 is top membrane) Install one of the following. 1. Gravel or slag applied at 400 Ibs.sq. and 300 lbssq. respectively in a flood coat of approved asphalt at 60 lbs./sq. or applied in a flood coat of Leak BusterTM MatrixTM 103 Cold Process Adhesive applied at a rate of 3 gal. /sq. 2. GAFGLAS® Mineral Surfaced Cap Sheet, GAFGLAS® Energy Cap Mineral Surfaced Capsheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20 -40 lbssq. 3. Leak BusterTM MatrixTM 303 Premium Fibered Aluminum Roof Coating, at 1.5 gal./sq. 4. Leak Buster"' MatrixTM 715 , Leak BusterTM Matrix"M . 322, TOPCOAT® MB +, TOPCOAT Fireshield Elastomeric Roofing Membrane, applied at 1 to 1.5 gal./sq. 5. Leak Buster"' MatrixTM 602 MB Xtra Elastomeric Roofmg Membrane, EnergyCote® roof coating applied at 1 to 1.5 gal. /sq. 6. TOPCOAT' Surface Seal, TOPCOAT' Fireshield® SB Solvent based Elastomeric Roofmg Membrane applied at lto 1.5 galsq 7. Advance Green Technologies Photovoltaic Laminate solar energy collector auxiliary roof equipment installed in compliance with manufacturer's specifications and applicable Building Codes, Maximum Design Pressure: -45 psf; (See General Limitation #7) APPROVED NOA No.: 07- 1219.09 Expiration Date: 11/04/13 Approval Date: 03120/08 Page 14 of 19 Deck Type 1I: Wood, Insulated Deck Description: 19/32' or greater plywood or wood plank System Type D: Insulation and Base sheet simultaneously All General and System Limitations shall apply. One or more layers of any of the following insulations. Insulation Layer loosely laid with firmly butted joints. EnergyGuardTM, EnergyGuardTM RA, Minimum 1.3" thick Insulation Fasteners Fastener (Table 3) Density/ft2 N/A N/A EnergyGuardm High Density Fiberboard, EnergyGuardm Fiberboard Minimum 1" thick N/A Fire Barrier: (optional) Base Sheet: N/A FireOutrid Fire Barrier Coating, VersaShield®NonAsphaltic Fiberglass -Based Underlayment or SecurockTM. Install one ply of GAFGLAS® #75, GAFGLAS® #80 UItima ULTIMA'"1 Base Sheet, GAFGLAS® STRATAVENT® EliminatorTM Nailable or RUBEROID® 20 base sheet applied over the loose laid insulation with 2" side laps mechanically fastened as described below; Fastening Options: Drill -TecTM #12 standard, #14 or # 15 Screws and 3" Drill-Teem steel plate or Drill -Teem AccuTrac Plates are installed through the base sheet and insulation in 3 rows 12" o.c. One row is in the 2" side lap. The other rows are equally spaced approximately 12" o.c. in the field of the sheet. (Maximum Design Pressure -45 psf, See General Lbnitation #7) Drill -Teem #12 standard, #14 or # 15 Screws and 3" Drill -TecTM steel plate or Drill TecTM AccuTrac Plates are installed through the base sheet and insulation in 4 rows 8" o.c. One row is in the 2" side lap. The other 3 rows are equally spaced approximately 9" o.c. in the field of the sheet. (Maximum Design Pressure —75 psf, See General Limitation #7) GAFGLAS® #80ULTIMATM, RUBEROID®20, RUBEROID® Mop Smooth, base sheet attached to deck with approved annular ring shank nails with a minimum embedment of 1" into the wood substrate and inverted 3" steel plate at a fastener spacing of 9" o.c. at the 4" lap and in two rows staggered with a fastener spacing of 9" o.c. in the center of the membrane. (Maxlmwm Design Pressure —60 psf,, See General Limitation #7) Drill -Teem #12 standard, #14 or # 15 Screws and 3" Drill-TecTM steel plate or Drill -Teem AccuTrac Plates in 4 rows 12" o.c. One row is in the 2" side lap. The other rows are equally spaced approximately 9" o.c. in the field of the sheet. (Maximum Design Pressure —60 psf, See General Limitation #7) One or more plies GAFGLAS® PLY 4, GAFGLAS ®, GAFGLAS® FIexPIyTM 6 sheet, #80 Ultima or RUBEROID® 20adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20 -40 lbs.sq. Ply Sheet: NOA No.: 07- 1219.09 Expiration Date: 11/04/13 Approval Date: 03/20/08 Page 15 of 19 Cap Sheet: (Optional) One ply of GAFGLAS® Mineral Surfaced Cap Sheet or GAFGLAS® EnergyCapTM Mineral Surfaced Cap Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs. /sq. Surfaeing: (Optional, required if RUBEROID® MOP Smooth or RUBEROID® 20 is top membrane) Install one of the following: 1. Gravel or slag applied at 400 lbsJsq. and 300 lbsJsq. respectively in a flood coat of approved asphalt at 60 lbsJsq. or applied in a flood coat of Leak Busterm MatrixTM 103 Cold Process Adhesive applied at a rate of 3 gal./sq. 2. GAFGLAS® Mineral Surfaced Cap Sheet, GAFGLAS® Energy Cap Mineral Surfaced Capsheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20 -40 lbsJsq. 3. Leak'BusterTM Matrix-114 303 Premium Fibered Aluminum Roof Coating, at 1.5 galJsq. 4. Leak BusterTM MatrixTM 715 , Leak BusterTM MatrixTM 322, TOPCOAT MB +, TOPCOAT® Fireshield Elastomeric Roofing Membrane, applied at 1 to 1.5 gal/sq. 5. Leak BusterTM MatrixTM 602 MB Xtra Elastomeric Roofing Membrane, EnergyCote® roof coating applied at 1 to 1.5 galJsq. 6. TOPCOAT® Surface Seal, TOPCOAT® Fireshield® SB Solvent based Elastomeric Roofing Membrane applied at 1to 1.5 galJsq 7. Advance Green Technologies Photovoltaic Laminate solar energy collector auxiliary roof equipment installed in compliance with manufacturer's specifications and applicable Building Codes. Maximum Design Pressure: See Fastening Above NOA No.: 07-1219.09 Expiration Date: 11/04/13 Approval Date: 03/20/08 Page 16 of 19 Deck Type 1: Wood, Non - insulated Deck Description: 19/32" or greater plywood or wood plank decks System Type E: Base sheet mechanically fastened. All General and System Limitations shall apply. Fire Barrier. (optional) FireOutTM Fire Barrier Coating, VersaShield®NonAsphaltic Fiberglass -Based Underlayment or SecurockTM. Base sheet: GAFGLAS® #80 ULTIMATM Base Sheet, STRATAVENT+ EliminatorTM Nailable, RUBEROID® Modified Base Sheet, RUBEROID® 20, RUBEROID® Heat- We1dTM Smooth or RUBERO1D Heat WeidTM 25 base sheet mechanically fastened to deck as described below; • Fastening Options: GAFGLAS® Ply 4, GAFGLAS® Flex PIyTM 6, GAFGLAS® #75 Base Sheet or any of above Base sheets attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" o.c. at the lap staggered and in two rows 12" o.c. in the field. (Maximum Design Pressure —45 psf; See General Limitation #7) GAFGLAS® Ply 4, GAFGLAS® Flex P1yTM 6, GAFGLAS® #75 Base Sheet or any of above Base sheets attached to deck with Drill -TecTM #12 standard, #14 or # 15 Screws and 3" Drill -TecTM steel plate or Drill -TecTM AccuTrac Plates, 12" o.c. in 3 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 12" o.c. in the field of the sheet. (Maximum Design Pressure —4S psf, See General Limitation #7) GAFGLAS® Flex P[yTM 6, GAFGLAS® #75 Base Sheet or any of above Base sheets attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" o.c. at the 4" lap staggered and in two rows 9" o.c. in the field (Maximum Design Pressure 52.5 psf, See General Limitation #7) GAFGLAS® #80ULTIMATM, RUBEROID®20, RUBEROID® Mop Smooth, base sheet attached to deck with approved 1'A" annular ring shank nails and inverted 3" steel plate at a fastener spacing of 9" o.c. at the 4" lap and in two rows staggered with a fastener spacing of 9" o.c. in the center of the membrane. ( Maximum Design Pressure --60 psf; See General Limitation #7) GAFGLAS® #75 Base Sheet or any of above Base sheets attached to deck with Drill -TecTM #12 standard, #14 or # 15 Screws and 3" Drill-Teem steel plate or Drill -TecTM AccuTrac Plates, 12" o.c. in 4 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 9" o.c. in the field of the sheet. (Maximum Design Pressure —60 psf, See General Limitation #7) Any of above Base sheets attached to deck approved annular ring shank nails and:3" inverted Drill-TecTM insulation plates at a fastener spacing of 9" o.c. at the 4" lap staggered in two rows 9" in the field. (Maximum Design Pressure —60 psf, See General Limitation #7) APPRQVED. NOA No.: 07- 1219.09 Expiration Date: 11/04/13 Approval Date: 03/20/08 Page 17 of 19 GAFGLAS® #75 Base Sheet or any of above Base sheets attached to deck with Drill -TecTM #12 standard, #14 or # 15 Screws and 3" Drill-TecTM steel plate or Drill -TecTM AccuTrac Plates, 8" o.c. in 4 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 9" o.c. in the field of the sheet. (Maximum Design Pressure —75 psf, See General Limitation #7} Ply Sheet: One or more plies of GAFGLAS® PLY 4, #80 ULTIMA, RUBEROID® MOP Smooth or RUBEROID® 20 adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20 -40 lbs. /sq. Cap Sheet: (Optional) One ply of GAFGLAS Mineral Surfaced Cap Sheet or GAFGLAS®EnergyCapTM Mineral Surfaced Cap Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20- 40lbssq. Surfacing: (Optional, required if RUBEROID® MOP Smooth or RUBEROID® 20 is top membrane) Install one of the following: 1. Gravel or slag applied at 400 lbs./sq. and 300 lbs.sq. respectively in a flood coat of approved asphalt at 60 lbs. /sq. or applied in a flood coat of Leak BusterTM MatrixTM 103 Cold Process Adhesive applied at a rate of 3 galJsq. 2. GAFGLAS® Mineral Surfaced Cap Sheet, GAFGLAS® Energy Cap Mineral Surfaced Capsheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. 3. Leak BusterTM MatrixTM 303 Premium Fibered Aluminum Roof Coating, at 1.5 galfsq. 4. Leak BusterTM MatrixTM 715 , Leak BusterTM MatrixTM 322, TOPCOAT® MB +, TOPCOAT® Fireshield Elastomeric Roofing Membrane, applied at 1 to 1.5 gal./sq. 5. Leak BusterTM MatrixTM 602 MB Xtra Elastomeric Roofing Membrane, EnergyCoteo roof coating applied at 1 to 1.5 galfsq. 6. TOPCOAT® Surface Seal, TOPCOAT® Fireshield® SB Solvent based Elastomeric Roofing Membrane applied at Ito 1.5 gallsq 7. Advance Green Technologies Photovoltaic Laminate solar energy collector auxiliary roof equipment installed in compliance with manufacturer's specifications and applicable Building Codes. Maximum Design Pressure: See Fastening Above NOA No.: 07- 1219.09 Expiration Date: 11/04/13 Approval Date: 03/20/08 Page 18 of 19 WOOD DECK SYSTEM LIMITATIONS: 1 A slip sheet is required with Ply 4 and Flex P1yTM 6 when used as a mechanically fastened base or anchor sheet. 2. Minimum 'A" Dens DeckTM or Y2" Type X gypsum board is acceptable to be installed directly over the wood deck. GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance, refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20- 40lbs.sq., or mechanically attached using the fastening pattern of the top layer 3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size shall be 4' x 4' maximum. 4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at each sidelap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 12 lbs. /sq. Note: Spot attached systems shall be limited to a maximum design pressure of -45 psi. 5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F') value of 275 lbf., as tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field - tested, are below 275 lbf. insulation attachment shall not be acceptable. 6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing, prepared, signed and sealed by a Florida Registered Engineer, Architect, or Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117. 7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred within this NOA, General Limitation #9 will not be applicable.) 8. All attachment and sizing of perimeter milers, metal profile, and/or flashing termination designs shall conform with Roofing Application Standard RAS 111 and applicable wind load requirements. 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners and corners). (When this limitation is specifically referred within this NOA, General Limitation #7 will not be applicable.) 10.. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9B-72 of the Florida Administrative Code. END OF THIS ACCEPTANCE 1 .APPROVED NOA No.: 07- 1219.09 Expiration Date: 11/04/13 Approval Date: 03/20/08 Page 19 of 19 FOIR (4) PLY INK.T UP MIS MAILABLE LECK 12 YEAR DIAMOND PLEDGE AND SYSTEM - BOIad- *EU - ANC# Magfida MAffiP:M N-13-4-M MOMENT' MADAM itraiMait MO UMW BASE MET IMBED SAEESIEET FlY 4 %MEM= PAPER HEW 6 NALED WPM NAILED NARED NAM NAAR) 15 YEAR DIAMOND PLEDGE AND SYSTEM ontEST WIPE otam - mics MEV . • NM% N84-111P6- WED NAILED NAB) NAM NAM STRADWan*NALASE BASES-EU UOMMraVESEE1 B A S E S T Fuswir symmos. ; • ; GENERAL Salty: R&M Sadist' Secron Ure. EX) for BEIM IliZIAllAWN tHILIMPEOMMION 15 READ, IMIIERSTOOD MVLEMEMED. MAMAS - Ma tatill RecOements-per 100 sq. ft; Asitadt (par iiy) 25 lbs. (122 kgraf) Base Meet 1 ply PITSheels 2 Fros Cap Meet 1 ply GLIARANIEE' MCI:MONS. EIREEIX PIY4 Ftig RY 4 RY 4 RY4 P�4 admix pet4 #14 RY 4 RY 4 RY 4 RY 4 SMEACM. CAP MEET CAPAW- CAP S-EET CAP MEET CAP 6I-EET CAP SEE! GMRANIEE WECWICATIOle MIBRIX Bffigtg _ HMV 6 FLEXPIY8 CAP SHEET RaPlY 6 FLORY 6 CAP Sl-EET ROCKY 6 REMY 6 CAP %EU - Fumy 6 -MARX 6 CAPAEET REMY 6 RUM' 6 CAP MEET UL Online Certifi' catio Home Ouick Glad' e Contact Us UL.com Directory 1 Roofing See General ktonnalion fir Roofing Systems GAF BUTE:RIMS CORP 1361 ALPS RD WAYNE, NJ 07470 LTSA 2. Deck C-15/32 - Incbm hisulagen (Optima* —Om we polyisotofausaate or madame or • amposile or wood Ply Sseee TIMM or more plies Typo aGAFGLAS Ply 6n. Cap Sheet — One ply Tip G3 Mona Surfaced Cap Sheet 3_ Deck NC Liana Intuladon (Opfionalk — One or more polyisoeyanorale, mem°, composii; wood Ply Sheet — Two or maze pfies Type DGAFGLAS Ply 6". - Cap Meet — One ply Type 03 , bfineral Surfaced. Cap 4. Deck Beek C-15/32 - Slip Slant (Optima* —Redrosin Base Sheet: — One ply Type Ci2 S (nmy bnana). Ply Sheet —One or mom pries Type GAMMAS Ply 6. Cap Ma* — One ply Type 03 Armand &awed Cap Sheer. R1306 per or vmod fiber or ilass fiber or amposite. or perfiteknOmne comilosfte lie,.any Melmss. or 'GAMMAS My 4" or- "M-Ply Ply 4" or i'L41311:-• :A11114.: I Mamal Surfaced Cap Sheer or "Tri-Ply • pprlite' , wood fiber, &is fiber, "tilt composite, perlliehereftwo phenolic, No_ imam= - "GOMM Ply 4n or "Tsi.-Ply Ply 4w, *lineal Seamed C 7/1-Ply =Bad' .io deck. _ #75 Bate S1' or "Td-P1#75 Base VrAiGLAS Ply 4" or "TriPly Ply 47 or - • birmand Surfaced Cap Skye or atii.-Ply x SECTION R4402.13 HIGH VELOCITY HURRICANE ZONES — REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS R4402.13.1 Scope. As it pertains to the section, it is the responsibility of roofing contractor to provide the owner with the required roofing permit, and to explain to the owner the content of the section. The provisions of Section R4402 govem the minimum requirements and standards of the industry for roofing system installations. Additionally, the following items should be addressed as part of the agreement between the owner ant the contractor. The owner's initial in the designated space indicates that the item has been explained. 1. t R Aesthetics- Workmanship: the workmanship provisions of Section R4402 are for the purpose of providing that the roof system meets the wind resistance and water instruction performance standards. Aesthetics (appearance) are not a consideration with respect to workmanship provisions. Aesthetic issues such as color or architectural appearance, that are not part of a zoning code, should be addressed as part of the agreement between the owner and the contractor. 2. �/ R Renailing wood decks: When replacing roofing, the existing wood roof deck may have to be renailed in accordance with the current provisions of Section R4403. (The roof deck is usually concealed prior to removing the existing roof system). 3. b R Common roofs: Common roofs are those which have no visible delineation between neighboring units (i.e., townhouses, condominiums, etc.) In buildings with common roofs, the roofing contractor and /or owner should notify the occupants of adjacent units of roofing to be performed. 4. QZ Exposed Ceiling: Exposed, open beam ceilings are where the underside of the roof decking can be viewed from below. The owner may wish to maintain the architectural appearance; therefore, roofing nail penetration of the underside of the decking may not be acceptable. This provides the option of maintaining the appearance. 5. Dg Ponding water: The current roof system and/or deck of the building may not drain well and may cause water to pond (accumulate) in low -lying areas of the roof. Pounding can be an indication of structural distress and may require the review of a professional structural engineer. Pounding may shorten the life expectancy and performance of the new roofing system. Pounding conditions may not be evident until the original roofing system is removed. Pounding conditions should be corrected. 6. DR Overflow scuppers (wall outlets): It is required that rainwater flows off so that the roof is not overloaded from a buildup of water. Perimeter /edge wall or other roof extension may block this discharge if overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in accordance with the requirements of Sections R4402, R4403 and R4413. 7. Ventilation: Most roof structures should have some ability to vent natural airflow through the interior of the structure assembly (the building itself). The existing amount of attic ventilation shall not be reduced. It may be beneficial to consider additional venting which can result in extending the service life of the roof. Owne 'gent's ' ignatu'!'- Date Revised on 7/9/2009 LD actor Signature Z -3-1 Date