Loading...
RF-11-1066Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Inspection Number: INSP- 160847 Permit Number: RF -6 -11 -1066 Scheduled Inspection Date: June 24, 2011 Inspector: Bruhn, Norman Owner: LEEMBURG, CYNTHIA Job Address: 361 NE 101 Street Miami Shores, FL 33138 -2424 Project: <NONE> Contractor: DALEY ROOFING INC Permit Type: Roof Inspection Type: Final Roof Work Classification: Tile /Flat Phone Number Parcel Number 1132060135220 Phone: (305)754 -9892 Building Department Comments re roof flat roof Passed' 6---)e7:-67- Failed Correction Needed Re- Inspection Fee No Additional Inspections can be scheduled until re- inspection fee is paid. Inspector Comments June 24, 2011 For Inspections please call: (305)762 -4949 Page 9 of 18 Q\\*-RA Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 BUILDING PERMIT APPLICATION FBC 2004 Permit Type (circle): Building Roofing Permit No. Rf _ i 1- 10 (9 6 Master Permit No. Owner's Name (Fee Simple Titleholder) J Owner's Address 31 1 & leIto I Sr City pticill4 1 SF1-O State Phone #1 Zip 3334 .'enant/Lessee Name Phone # Job Address (where the `work i� being done) City Miami Shores Village County Miami -Dade Zip 35) FOLIO / PARCEL # Is Building Historically Designated YES NO Contractor's Company Name Doc of COO emi 1-k/C. Phone # 35 7`=-, I v- Contraact/or's Address -7g I _ -1 U i8 City / `'1 l JIM) -Clitatea State ` Zip 3-3), Qualifier Name l, e batef Phone # State Certificate or Registration No. O -MOS -] K-10 Certificate of Competency No. Architect/Engineer's Name (if applicable) Phone # Value of Work For this Permit $ 62 .50. 06 Square / Linear Footage Of Work: 210g Type of Work: LlAddition ' DAlteration DNew i1 Repair/Replace ❑ Demolition Describe Work: , tt Submittal Fee $ 50-0D Permit Fee $ c:)So`'e) CCF $ CO /CC l,A.t a Notary $ Training/Education Fee $ Technology Fee $ Scanning $ Radon $ DPBR $ Zoning $ Bond $ Code Enforcement $ Double Fee $ Structural Review. $ Total Fee Now Due $ 9.,N10 L__ See_ Reverse side Bonding Company's Name (if applicable) Bonding Company's Address City tate Zip Mortgage Lender's Name (if applicable Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC OWNER'S AN'N'IUAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Owner or Agent The foregoing instrument was acknowledged before me this 3 N day of tl�--�t� 20 I t , by (NIT \--1 U — ` .Xt , who is personally known to me or who has produced As identification and who did take an oath. ∎ \ \\\\,Ul I l l n l l I ����� ®r! NOTARY PUBLIC: Sign: Print: My Commission Expires: �® ®• .... ****************************************/444****** ,, / /llIIItItO APPLICATION APPROVED BY: (Revised 07/10/07) Signature 0,0 P. a Contractor The foregoing instrument was acknoiged befole day of Zi16, ,e ,20 lL ,by whe-is-persatiallutown to me or who has produced as identification and who did take an oath. NOT PUBLIC: Sign: Print: ° V• X11 O�IeR� Cia o° � 11,7 p, My Commission Expires: s'''n��spp� C y ' 4 ��°� **** k**** kk *kkktikkkkkkkk** ** k *� kkkkkk*** Plans Examiner Engineer Zoning Miami Shores Viiiage Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 OWNERS'S AFFIDAVIT OF EXEMPTION ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR EXISTING SITE - BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES PERSUANT TO SECTION 553.844 F.S. To: Miami Shores Village Building Department 10050 NE 2nd Ave Miami Shores, Fl 33138 Re: Owner's Name: e,yi\mi -i D2reik/01/4/ Property Address: 'ti) A 101 ST Date: Roofing Permit Number: Dear Building Official: I e buoy building because: 'The just valuation for the structure for purpose of ad valorem taxation is less than $300,000.00. Please attach proof of ad valorem taxation. certify that I am not required to retrofit the roof to wall connections of my ❑ The building was constructed in compliance with the provisions of the Florida Building Code (FBC) or with the provisions of 1994 edition of the South Florida Building Code (1994 SFBC) State of Florida County of Dade The undersigned, being the first duly sworn, dep ' ses and says that he /she is the owner for the above property mentioned. Sworn to and subscri bed before me this day of 1.a. Notary Public, Sate of Florida at Large %/ •� • ®o • When the just valuation of the structure for purpose of ad valorem taxation is equal to or more than 0,008:0 an�' ; �x�as not constructed with FBC nor a 1994 SFBC. Then you must provide a building application from a General Contractor for the Roof to Wail connk t)on Hut * 'h. /rrrrrivaitiol0 Revised on 5/21/2009 HIGH VELOCITY HURRICANE ZONES - REQU R4402.13.1 Scope. As it per(ains to the section, d is the responsibility of roofing --� �Nprovide the aowner with the required roofing permit, and to explain to the owner of the ection. The '—'-- noof Section R4402 govern the minimum ualu memen�ond8t�ndmn�sof�8 - ' �xroofing system installations. Additionally, the following items shoud be addressed as part of the agthe owner ant the contractor. The owner's initial in the designated space indrcates that the item has been explained. ,Dh�\ 1 . / '0~�pl ^_' mwsxnetxom-Wmwkmmmmahip: the wm*monnhi provisions ' mfSmcUonR44O2enafnrthapurpuueof providing that the roof system meets the wirwl resstance and water instruction perfomiance standards. Aeothohoo(appoamncm) onenoteounoidoraUonwkheapecttuwmrhmanmhippmwiuiona.Aau1hmbu|mo issues such eo color orarchUec�[a| appearance, that are not pm�Of8 zoning code, should bo addressed an --�of the agooen)entba��/nthe ovmnmrand the contractor. '~ ' i//'\ C"'RmmmiWn0wood decks: When replacing nonOno. the existing wood roof deck may have to be nana|hedin accordance wdhthe ou�mntpmv�in provisions O3./TMm�of deck iSusuaUy concealed phVr bo removing the eximdng roof system). ` 1 3. Common roofs: Common roofs are those which have no visible units (i.e., condom��mo.�o](nbxUd�onv�h common roofs, delineation -----'''~'''~~� owner ohouNno0��em:cupan�nf adjacent un�u roofing tVhepe��—'' � --- ---- � Ceiling: Exposed, operi beam ceilings are where the underside of the roof clecking can be viewed from below. The owner may wish to maintain the architectural appearance; therefore, roofing nail penetration of the underside of the decking may not be acceptable. This provides the option of maintaining the appearance. 0~21' Ponding water: The current roof system and/or deck m the ounomnmavnot ooanvwn and may cause wate to pond in /reaanf�wnx�. can ~ mo^indication of atruoun, distress and may require the review of a professional structural engineer. Pounding may shorten the Iife ncy and performance of the new roofing system. Pounding conditions may not be evident until the original roofing system is removed. Pounding conditions should be corrected. W. Overflow scuppers (wall outlets): It is required that rainwater flows off so that the roof is not overloaded from a buildup of water. Perimeter/edge wall or other roof extension may block this discharge if overflow scuppers (wall out(ets) are not provided. 11 may be necessary to install overflow scuppers in • accordance with the requirements Of Sections R44O2.R44O3 and R4413. 7. /.APO Ventilation: Most roof structures shoutd ha? bi |i ^ at nW i[O through th e interior of the s\ru nUm vm assembly (the building itself). The ex imti ga° nctir� afti.cEventilation VhaUUOtbe " 1- beneficial to consider additional ventireNtia caaegiiirce4egiing the service life of the nature Date °•° ¶.'!: ° •° / .big ' /' / * ° : • °• ° :Date • •• • • °- ° ° °°°° °°°°=° • • • °°° • • • • ▪ � • *��� • �°� • °°*°�° • • • • °°° • • • °°° • • ROOF ASSEMI UES AND ROOFTOP STRUCTURES Florida Building Code Edition 2004 High-Velocity Hurricane pane Uniform Fenn ft Application Form. $ec jqn A (Generni InfQnnntion) Master Permit No. Process No. Contractors Name DYhCL/ cQ (C1 �(-1 Job Address 3 2 / iLt- / C Slope 0 Asphaltic Shingles ROOF CATEGORY ® Mechanically Tile D Metal Panel/Shingles ® Prescriptive BUR -RAS 150 ROOF TYPE O Mortar /Adhesive Set Tile O Wood Shingles/Shakes o New Roof jerooflng 0 Recovering 0 Repair 0 Maintenance ROOF SYSTEM INFORMATION Low Slope Roof Area (SF) Steep Sloped Roof Area (SF) Total (SF) 20S; Section. B (Roof Plan).. Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly Identify-dimensions of elevated pressure zones and location of parapets. 15.32 immlnimmiseene....ErrEraimmimmum Imumninnumomonommilinosionunio 11111111111111111111111111111111111MOMM111111111111111111111111111111111111 NommunEmmiiiiimmimeanitutinim SOO ••••• • • •• • •. ...• • • ..... • • • • • • • • • • FLORIDA BUILDING CODE — g11tLDING 4 ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Florida Building Code Edition 2007 High - Velocity Hurricane Zone Uniform Permit Application Form. l Section C (Low Slope Application) Fill in specific roof assembly components and identify manufacturer (If a component is not used, identify as "NA ") System Manufacturer Product Approval No.: Design Wind Pressures, From RAS 128 or Calculations: Pmax1: Pmax2: Pmax3: Max. Design Pressure, from the specific Product Approval system: Deck: Type: I Y Gauge/Thickness: Slope: Anchor/Base Sheet & No. of Ply(s): Anchor/Base Sheet Fastener/Bonding M - : rial: Insulation Base Layer Base Insulation Size and - ickness: Base Insulation Fas; > er/Bonding Material: Surfacing: Fastener Spacing for Anchor/Base Sheet Attachment: Field: 67 " oc @ Lap, # Rows r @ / " oc Perimeter: ' " oc @ Lap, # Rows LI @ " oc Comer: 11" oc ® Lap, # Rows @ " oc Number of Fasteners Per Insulation Board: Field Perimeter Comer Illustrate Components Noted and Details as Applicable: Woodblocking, Gutter, Edge Termination, Stripping, Flashing, Continuous Cleat, Cant Strip, Base Flashing, Counter - Flashing, Coping, Etc. Indicate: Mean Roof Height, Parapet Height, Height of Base Flashing, Component Material, Material Thickness, Fastener Type, Fastener Spacing or Submit ET_ Top Insulatio Layer: Top Ins ation Size and Thickness: To • ' nsulation Fastener/Bonding Material: Base Sheet(s) & No. of PIy(s): r Pt ;t' 4477 Base Sheet Fastener/Bonding Material: 1.5/A tint (I.p, trial, Ply Sheet(s) & No. of PIy(s): ,vj Ply Sheet Fastener /Bonding Material: IA 124 Top PIy: Top Ply Fastener/Bonding Material: FLORIDA BUILDING CODE — BUILDING • • • • • • • • • •• ••• •• • • • •• • ••• • • • • • .• .•• ••• • • • • • • • •• •• • • • • • • • • • • • • • • • • • • • • • • • • •• • • • • • • • • • •. • ••• • • • • • • • • • • • • • •• •• ••• • • • • ••• • • • • • • • ••. • • • • • • • • • • • • •• •• • ••• • • Parapet Hecht I t r l6 Mean Roof Height BUILDING CODE COMPLIANCE OFFICE (BCCO) PRODUCT CONTROL DIVISION NOTICE OF ACCEPTANCE (NOA) GAF Material Corporation 1361 Alps Road Wayne, NJ 07470 MIAMI -DADE COUNTY, FLORIDA METRO -DADE FLAMER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 MIAMI, FLORIDA 33130 -1563 (305) 375 -2901 FAX (305) 375 -2908 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by the BCCO and accepted by the Building Code and Product Review Committee to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Division that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code and the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: GAF RUBEROID®Modified Bitumen Roof System for Wood Decks. LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement "Miami Dale County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provideei to. he user by the manufacturer or its distributors and shall be available for inspection at the jot site at request of th Wilding Official. This NOA revises NOA No. 07- 1203.01 and consists of •pages • Z"thro412 317 : • •▪ •• The submitted documentation was reviewed by Jorge L. Acebo. PP ROVED ••. ••• • • • . • • •• •• •_ • • • •.NOVA No.: 09- 0224.01 • • • Fi@iratiin Date: 11/06/13 • • •Approval Date: 04/08/09 Page 1 of 31 • • • ••• • • • • • •.• • • • • • • • •• •• • • • ••• • • • • ••■ • • • • • • • •• • Membrane Type: APP /SBS Heat Weld Deck Type 1: Wood, Non - insulated Deck Description: 19/32" or greater plywood or wood plank decks System Type E(2): Base sheet mechanically fastened. MI General and System Limitations shall apply. Fire Barrier: Fire OutTM Fire Barrier Coating, VersaShietd®Non-Asphaltic Fiberglass-Based Underlayment or SecurockTM. 'berglass -Based Base sheet: GAFGLAS® #80 ULTIMATM Base Sheet, STRATAVENT® EliminatorTM Nailable, RUBEROID® Modified Base Sheet, RUBEROID® MOP Smooth, RUBEROID® 20, RUBEROID® SBS Heat- WeldTM Smooth or RUBEROID® SBS Heat-Weld 25 base sheet mechanically fastened to deck as described below;. Fastening Options; GAFGLAS® Ply 4, GAFGLAS® Flex Plym 6, GAFGLAS® #75 Base Sheet or any of above Base sheets attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" o.c. at the lap staggered and in two rows 12" o.c. in the field. (Maximum Design Pressure -45 psf, See General Limitation #7) GAFGLAS® Ply 4, GAFGLAS Flex PIyTM 6, GAFGLAS® #75 Base Sheet or any of above Base sheets attached to deck with Drill -TecTM #12 standard, #14 or # 15 Screws and 3" Drill -TecTM steel plate or Drill -TecTM AccuTrac Plates, 12" o.c. in 3 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 12" o.c. in the field of the sheet. (Maximum Design Pressure -45 psi; See General Limitation #7) GAFGLAS® Flex PlyTM 6, GAFGLAS® #75 Base Sheet or any of above Base sheets attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" o.c. at the 4" lap staggered and in two rows 9" o.c. in the field. (Maximum Design Pressure 52.5 psf, See General Limitation #7) GAFGLAS® #80 ULTIMATM, RUBEROID® 20, RUBEROID® Mop Smooth, base sheet attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" o.c. at the 4" lap staggered and in two rows 9" o.c. in the field. (Maximum Design Pressure -60 psf, See General Limitation #Z GAFGLAS® #75 Base Sheet or any of above Base sheets attached to deck with Drill -Teem #12 standard, #14 or # 15 Screws and 3" Drill -TecTM steel plate or Drill -Teem AccuTrac Plates, 12" o.c. in 4 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 9" o.c. in the field of the sheet. (Iffedmum Design Pressure - 60psf,, See General Limon #7) Any of above Base sheets attached to desk v ed annular sin .shank nails and 3" inverted Drill -Teem . • insulation phhts at a . �;n��9° o.c. at the 4" lap staggered in two rows 9 in the ficjij■ .. • •.: •.' : : .. • (MaadmumDesign Pressure - 60psf, See GeneralL'on #7) •.• ••• • • • • • • • •••• •••• • • • • • • •' ' ' • 114 J1oa: 09-0224.01 .• •• • • . • • Expirat1oz Date: 11/06/13 Approval Date: 04/08/09 ••• • • • • • • • • • • • • • • • • • • ••• • • • • • • • • • • • • • •• • •• • • •• •• .•• • • • • • • • • • Page 29 of 31 GAFGLAS® #75 Base Sheet or any of above Base sheets attached to deck with Drill -TecTM #12 standard, #14 or # 15 Screws and 3" Drill -Tech steel plate or Drill -TecTM AccuTrac Plates, 8" o.c. in 4 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 9" o.c. in the field of the sheet. (Mwdnuan Design Pressure —75 psf, See General Limitation #7J Ply Sheet: (Optional except over RUBEROID® Modified Base Sheet, RUBEROID® MOP Smooth, RUBEROID® 20, RUBEROID® SOS Heat We1dTM Smooth or RUBEROID® SBS Heat We1dTM) One or more plies GAFGLAS® PLY 4 or GAFGLAS® Flex PIyTM 6 sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbsJsq: or RUBEROID® Torch Smooth torch applied according to manufacturer's application instructions. Membrane: One ply of RUBEROID® Torch Smooth, RUBEROID® Torch Granule, Roof Match"' APP Torch Granule, RUBEROID® EnergyCapTM Torch Granule FR, RUBEROID® Torch Plus Granule, RUBEROID® EnergyCapm Torch Plus FR, or RUBEROID® Torch FR torch applied according to manufacturer's application instructions. Or One or more plies of RUBEROID® SBS Heat We1dTM PLUS, RUBEROID® SBS Heat We1dTM PLUS FR, RUBEROID® SBS Heat WeldTM 170 FR, RUBEROID® EnergyCapTM SBS Heat We1dTM Plus FR, RUBEROID® SBS Heat- We1dTM, RUBEROID® SBS Heat We1dTM Smooth, RUBEROID® ULTRACLAD® SBS and RUBEROID® SBS Heat We1dTM 25 applied according to manufacturer's application instructions. Surfacing: (Optional, required if RUBEROID® MOP Smooth or RUBEROID® 20 is top membrane) Install one of the following: 1. Gravel or slag applied at 400 lbs.sq. and 300lbs.sq. respectively in a flood coat of approved asphalt at 60 lbs.sq. or applied in a flood coat of Leak BusterTM MatrixTM 103 Cold Process Adhesive applied at a rate of 3 gal./sq. 2. GAFGLAS® Mineral Surfaced Cap Sheet, GAFGLAS® Energy Cap Mineral Surfaced Capsheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs.sq. 3. Leak Busterm MatrixTM 303 Premium Fibered Aluminum Roof Coating, at 1.5 gal./sq. 4. Leak BusterTM MatrixTM 715, Leak Busterm MatrixTM 322, TOPCOAT® MB +, TOPCOAT® Fireshield Elastomeric Roofing Membrane, applied at 1 to 1.5 galJsq. 5. Leak BusterTM MatrixTM 602 MB Xtra Elastomeric Roofing Membrane, EnergyCote ®roof coating applied at 1 to 1.5 gal./sq. 6. TOPCOAT® Surface Seal, TOPCOAT® Fireshield® SB Solvent based Elastomeric Roofing Membrane applied at Ito 1.5 galfsq 7. Advance Green Technologies Pho; evoltaie Laminate solar massy collector auxiliary roof equipment insta1led'i p corinpligdnge'vit t thiutacturer's specifications and applicable Builiidg Cale%; • • • • • • Maximum Design Pressure: See Fastening Above ••• ••• • • • • • • •••• •••• • • • • • • • , •NAAI No.: 09- 0224.01 • • • • • • • • • • Exgiq;atle�, bate: 11106/13 • • • Approval Date: 04/08/09 Page 30 of 31 ••• • • • • ••• • • • • • • • • • • • • • • • • ••• • • • • • • • • • • • • • • • • • • • •• • •• • • • • • • • • • • ••• • • • • ••• • • WOOD DECK SYSTEM LIMITATIONS: 1 A slip sheet is required with Ply 4 and Flex Ply 's° 6 when used as a mechanically fastened base or anchor sheet. 2. Minimum 'An Dens Deck or'/a" Type X gypsum board is acceptable to be installed directly over the wood deck GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance, refer to a current Approved Roofing Materials Directory for fire ratings of this product 2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20- 401bsJsq., or mechanically attached using the fastening pattern of the top layer 3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size shall be 4' x 4' maximum. 4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in time rows, one at each side lap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 121bsJsq. Note: Spot attached systems shall be limited to a maximum design pressure of -45 psL 5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F) value of 275 lbf., as tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field - tested, are below 275 lbf. insulation attachment shall not be acceptable. 6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing, prepared, signed and sealed by a Florida Registered Engineer, Architect, or Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117. 7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred within this NOA, General Limitation #9 will not be applicable.) 8. All attachment and sizing of perimeter milers, metal profile, and/or flashing termination designs shall conform to Roofing Application Standard RAS 111 and applicable wind load requirements. 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners and corners). (When this limitation is specifically referred within this NOA, General Limitation #7 will not be applicable.) 10. All products listed herein shall have a quality assurance aualf irf ccirdtaco with the Florida Building Code and Rule 9B-72 of the Florida Administrative Code. • • • • • • ••• ' • END OF THIS ACCEPT:A) C • :: • • • • ••• • e • • • Ii(1E► No.: 09- 0224.01 • • • • • • • • • • •Espii�ai4 Date: 11/06/13 • • • Approval Date: 04/08/09 Page 31 of 31 ••• • • • • • • • • • •• • ••• • • • ••• • • • • • • • • ••• • • • • • • • • • • • • •• •• • ••• • • TGFU,R1306 - Roofing System3 Primer: — "Fire Our applied at 1- gal /100-ft". Base Sheet — One ply Type 62 "GeAFGLAS y75 Base Sheet ", or'Th -Ply a'75 Base Sheet", mechanically fastened. Membrane: — "Ruberoid Torch Granule" er'Ruberad Torch Granule i' or "Ruberoid Torah Granule Pies° or "Ruberoid 'torch FR" heat fused. Page 14 of 48 50. Deck: C -15/32 Inclines 1/2 Primer: — "/rue Out" applied at 1- gal /100 -fr2. Base Sheet — One ply Type G2 "G. G.AFGL AS S75 Base Sheet ", or 'Tri4ly *75 Base Sheet ", mechanically Fastened. Ply Sheet ( Optional): — One ply Type GI or Type G2, mechanically fastened. Membranes "P.uberoid Torch Granete "or "Ruherold Torch Granule 1 ".r "Rub :road Torch Granule Rosner "Ruberoid Torch FR° heat fused 51. Dedt: NC Incline: 1/2 Insulation (Optional): — Min 1/2 In. wend fiber, mechanically fastened. Slip Sheet (Optional): - 1 ply "StormSafe" me t:nieally fastened. Base Sheet — One ply "Liberty $BS Self- Adhering Base /Ply Sheer or "Ruberoid 3A Base/Ply Sheet" self adhered. Membrane: — One ply "Ruberoid SBS Heat Weld 170 PR' or "Ruberoid 30 PR" or `Ruberoid energyCap 585 30 Mt' or "Rubarold 585 Heat Weld Pius PR" heat fused. 52. Doddt: C -15/32 Inclines 1/2 Insulation (Optional): — Any UL Classified, any thnt:rims, mechanically fastened. Barrier Board: — minimum 1 /2 -in. Mitt gypsum board or minimum 1/4 -In. thick G -P Gypsum Corp "DensOack ® Roofkoard" or "DensDeck Primat°j Roo/board" or `Genet/ace Darativard " 3oafboard" mechanically fastened. Base Sheet — One ply "Liberty SW Self - Adhering Base /'Ply Sheet" or "Ruberoid $A Base/Ply Sheet" self adhered. Membrane: — One alp "Ruberoid 5135 Heat Weld 170 PR° or "Ruberoid 30 FR" or "Ruberoid Bnsrgytap SW 30 FR" or "kub rotd 555 Heat Weld Pius PR" heat fused. 53. Dealt: NC Incline: 1 Primer: —'Fire Out' apphed at 1- gaN100 -ft2. Base Sheet (Optional): -- One ply "Liberty MA Base Sheet, mechanically fastened. Ply Sheet — One Fly "Liberty S95 Self-Adhering Base/Ply Sheet" or "Ruberoid SA Ease/Ply Sheet° self adhered Cep Sheet: -- One ply °Liba*i FR SBS Self- Adhering FR Cao Sheet" or " Ruberoid SA Cap FR Sneer self adhered. 54. De k: C -15132 Incline: 1/2 Primer: — "Fire Out" aprOid at 1-gal/z00-ft:. Slip Sheet (Optional): t ply "StormSafe" mechanically fastened. ease Sheet (Optional): — One ply "Liberty MA Base Shea", rr,ecranically fastened. ply Sheets One Pty "Liberty 5135 Self-Adhering Base/Ply Sheet" or "Ruberoid SA ease /Ply Sheet" self adhered. Cep Sheet: — One ply "Liberty PR 585 3e?fatahering FR Ca? Sheet" or "Ruberoid SA Cap FR Sheaf° self adhered. 55. Dade: NC lndlnc: 1 Insulation (Optional): — Perlite, fiber glass, polyls.ocyanurate, urethane or partite /polylsoryanurate composite, Oise: 6 -in. from joints. Base Sheast: — One or more plies Type G2 "GAPGtAS #75 Base Sheet', or "Tri -Fly #75 Base Sheer, or Type 03 "GAFGLAS Mineral Surfaced Cap Sheet", ar `Tri -Ply Mineral Surfaced Cap Sheet", hot mopped or mechanically fastened. MY Sheet (Optional): a- One or more plias Type Gt, hot mopped In place. Membrane: — One ply "Ruberoid Torch Smooths or "Ruberoid Mop Smooth ". Membrane: -- One ply " Ruberoid Mop FR ". 56. Deck: NC Incline: 1 • •• ••• • • • • • •• • • • • It�aulatiOn (Optional): Polyiaocyanurate, viand fiber, periita, glass fiber, a7/ thklanecs,3oEm)ip,r -r,'�r n{trihanically fastened Base Sheet: — time or more piles Type 02 `GAPGLAS #75 Base Sheet`, orfri- PIif"/5 Stee Sheer, fastened. Ply Sheet t — One or more plies " Ruberoid 20 ". hot mopped in place Membrane: — One ply "Ruberoid 585 Haat a +. " us FR" or "Club -road gPR°, last w8lded rn place. ••• ••• • • • • • • • • • • • • • • 57. Deeds: C -15/32 Incline: 1/2 •• •• • •• • • • • ••• • • • • • • • • Base Street: — Two or more plies Type 02 "GAFCLAS >r7S Base Shaer" or ''Tr;-Ply *75 Base Shea ', mcahanieaiiy fastened. Membrane: -- One ply "Ruberoid SBS Heat Weld Pius Fit" cr "Ruberoid WS Heat Weld 170 FR" heat welded in place. ••• • • • • ••• • • • 1 • • • • • • • • • • • • •._- - -- • •• • :-- �• •— --Tj r, • • • • ••• • • • ••• • •