RF-11-1042
Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 nspection Number: INSP - 161534 Permit Number: RF -6 -11 -1042 Inspection Date: July 01, 2011 Inspector: Rodriguez, Jorge Owner: MORRONGIELLO, ALEXANDER Job Address: 25 NE 101 Street Miami Shores, FL 33138- Project: <NONE> Contractor: ACE PROPERTY SERVICES CORP Permit Type: Roof Inspection Type: Final Roof Work Classification: Tile Phone Number Parcel Number 1132060131520 Phone: 305 - 598 -1700 Building Deaartment Comments RE ROOF TILE TO TILE EXCLUDING FRONT SLOPE ROOF Passed Inspector Comments CREATED AS REINSPECTION FOR INSP- 160743. 1//1/1/7/1--- 6')'� Failed Correction Needed Re- Inspection Fee No Additional Inspections can be scheduled re- inspection fee is paid. until For Inspections please call: (305)762 -4949 July 05, 2011 Page 1 of 1 FLORIDA INTERNATIONAL ENGINEERING & TESTING LAB INSIGEIT • INNOVATION. IN I EGEAI ION FLORIDA INTERNATIONAL ENGINEERING AND TESTING LAB LLC 16701 SW 117 Avenue, Miami, Florida 33177 Telephone: (305) 378-1991- Fax: (305) 378 -1997 Miami Dade Lab Certification # 07- 0612.11 SITE SPECIFIC INFORMATION Job Address: 7,5 f4 W, 0ta / Sr., A414/44 1 © Ie Install Date: e. ? v . !/ Contractor: es R0 pg A 1 64--AV feS I Permit # ".6. // /04a Test Date: 4.277'• 1/ Type o TYP of Tile: l74 T nip; - toA'a4 S417'7- Approx. Height -zi g, Floor: 2 41 Owner Name: R4cL„Aei A149,44 Slope: r$ / Z 101 App. Sq.Ft: /, roe Testing Equipment: 121 Shimpo 2 i Representatives of Florida International Engineering and Testing Lab., Inc performed the static load test on the roofing tile at the above referenced project. The purpose of this testing was to verify whether the installed tile roofing system is capable of resisting the applied test load of 45 pounds uplift force. This testing was performed in general accordance with Miami Dade Building Code Protocol TAS 106. The static load was applied utilizing a calibrated scale and force measuring instrument (dynamometer). A hook which is connected to the loading instrument was placed under the exposed edge of the tile. Test load of 40 pounds force (lbf) was applied and also held for more than 5 second at each test location. In addition to the static load test, the tested tile was also visually inspected for any kind of adhesion failure after completion of each test. No. Result No. Result No. Result No. Result No. Result No. Result No. Result 1 pki 21 p466 41 61 81 101 121 2 i • 22 42 62 82 102 122 3 23 43 63 83 103 123 4 24 44 64 84 104 124 5 25 45 65 85 105 125 6 26 46 66 86 106 126 7 27 47 67 87 107 127 8 28 48 68 88 108 128 9 29 49 69 89 109 129 10 30 50 70 90 110 130 11 31 51 71 91 111 131 12 32 52 72 92 112 132 13 33 53 73 93 113 133 14 34 54 74 94 114 134 15 35 55 75 95 115 135 16 36 56 76 96 116 136 17 37 57 77 97 117 137 18 38 58 78 98 118 138 19 39 59 79 99 119 139 20 / 40 60 80 100 120 140 Based on our findings, we conclude that the installed roofing tile at the above referenced project is capable to resist the applied test load. Therefore we conclude that it meets the Miami Dade Building Code Compliance Protocol TAS 106. Attached is the roof plan showing approximate test locations. Respectfully Submitted: G 2d -n Viaayagar M. Bahskrishnan V, P .E. State of Florida Lie # 63107 Job A d d r e s s : 2 c A i m . /D / Sr:, /(/ /ii-Ay I `+4/C ,� F/ rti Contractor. �.�l� Other. pqj Sketch of Roof ■•1■11111 111111111111111111111111111111■ ■■ 111111■111111111111111111111111 ■11111■ ■■■1111■■ 1111111111111111111111111111111 111111111111 1■11111111M1Mu11i111111■ ■■1111111 11111IN11111111111111111111■11■ ■■11■■1111 111111111i111111E11111i111111■ ■■11111111 11M1111111s111111M11111111111■ ■■111111 ■1 11111111111111111.11111111111111 111111■■11 1 11111■1111C1111111111!11111111■ ■111111111111111111 111M111I1111111111■ 1•11111111111 11111111i1111/111H1M1M1111 ■111 ■1111 ,111i15YS 1111111111111111111111111111 ■11111111x!! 1I1E':1UUt1R1111t11i1111>1111■ 1111111111101MME 111'11111111111111111111 111111111111PIi 11111111111111111111111111 ■111111111■ 1/+i���ta���111111111i11111111■ ■111111 �1[ � 111[���lc���111111111111111111■ 11111111111111111111MMEINCISIMEMNIMMINMEM ■1111111©1 1C1■11r'71/1111111111111111111■ 1111111 111111 ■1 idEt alIM1t1E1111111111■ ■11111111 x711c ■ti1?l111111111111.111i11■ 1111111l11i/11MrEIMMEi111111111111111■ ■11111111•W71r!I1/! 111!1 11111 ■1111 ■11111111 ■111•11 1P1MI IMIi1i11t1'111111111t111111i1■ ■111111 1 /1N111MMEII111<i IMME11111111■ ■■11111111MILM IUL'J111111M111 ■111IIi1111■ 11111111111111111d111111ELidI 1111111i1111M ■111■111 11111111i%P�11111/11i111111111■ ■111111 1111 ■1111IiiIId�1111111111111111111 1111111111111111111111121111WMPRINEMIHIMINIMMINIMIMIN ■1 ■11 11111111 .;J1 /I1[j */"11111111111111111■■ ■111111111111ai111;1i1i11M111INiMIUMUI ■111111 11111111111rt11i111111111111111 11■ ■11111111 ET Z SCIMZ1 OI1111111M11111111■ ■1111111111 11111111t111111111111111>111■ Notes 61-4:,S7Oes .S CFN: 20110360878 BOOK 27709 PAGE 1003 DATE:06/02/2011 04:25:17 PM HARVEY RUV1N, CLERK OF COURT, MIA-DADE CTY NOTICE OF COMMENCEMENT A RECORDED COPY MUST BE POSTED ON THE JOB SITE AT TIME OF FIRST INSPECTION PERMIT NO. TAX FOLIO NO. /1- 32D6 - 0/3-1g to • STATE OF FLORIDA: COUNTY OF MIAMI -DADE: THE UNDERSIGNED hereby gives notice that improvements will be made to certain real property, and in accoriiance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement. Space above reserved far use of recording office 1.1Lsga1 deacriptioim� of property and.street/address: 25 NF /O t ST �ittsr� r r 3 3/ ag 3 `l/ - 6 57 `12 �l t a„ , S ko•r-er .q c ( AvrI D P 10-7,0 C 15 !S /% 11 2. Description of improvement Re Roofing 3. Owner(s) name and address: 41aua-r o Nc1 2 NC t4"l I FL 33 J 3 a Interest in property: Owner A8 LI rC- o C- / Name and address of fee simple titleholder. 4. Contractor's name, address and phone number: ACE PROPERTY SERVICES CORP 10871 SW 188 St, 8 Miami, FL 33157 #305.588.1700 5. Surety: (Payment bond required by owner m contractor, if any) Name, address and phone number. Amount of bond $ 6. Lender's name and address: 7. Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)7., Florida Statutes, Name, address and phone number: 8. In addition to himself, Owners designates the following person(s) to 7J3.13(1)(b), Florida Statutes. Name, address and phone number. a copy of the Lienor's Notice as provided in Section 9. Expiration date of this Notice of Commencement: (the expiration date is 1 year from the date of rewding unless a different date Is specified) WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART I, SECTION 713.13. FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. Signature(s) of • r • ner(s)' Authorized Officer/Director/Partner/Manager Prepared By ` ) Prepared By Print Name /'?4i �et. Wow.ic -t Print Name Title/Office C)e-h-4ert.. Title/Office STATE OF FLORIDA COUNTY OF MIAMI -DADE The foregoin ' s ant w acknowledged e ore me this �BY C1 w ndiv ually, or O as naily known, or ❑ produced the following type of id Signature of Notary Public: Print Name: (SEAL) VERIFICATION PURSUANT TO SECTION 92.525. FLORIDA Under penalties of perjury. I declare that i have read the forego' that the facts stated in it are true, to the best of my knowledge 1S day of for entiff atio ,) • l /Illit� z Li: WAD VEGA• LIES fiDD791450 AssCa g d Signature(s) of Owner(s) or Owner(s)'s Authorized Officer /Director /P By By 104147 PAGE 8 3/,0 Prepared By:C.PuUes 10871 SW 188 St,8 Miami, FL 33157 0305.242.5055 eliet. anager who signed above: STATE OF FLORIDA, COUNTY OF DADE I HEREBY CERTIFY that the foregoing is a true and copy the original on 2U It title une 0 I HARVEY RUVN. CLERK. of ClrcuJf nd County Courts. Deputy Clerk mow", � u%r1 R Mn. Clerk Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 INSPECTION'S PHONE NUMBER: (305) 762.4949 BUILDING PERMIT APPLICATION FBC 20 Permit Type: BUILDING OWNER: Name (Fee Simple Titleholder Address: 95 RE j O{sT City: 61 [ '1 .t S hotre 5 JUN 0 7. 2011 0,-.N1 Permit No. PV Master Permit No. Phone #7 L)99- - `I37fg State: I �� Zip: 33 r Tenant/Lessee Name: - Phone #: -� Email: JOB ADDRESS: PS WE 10 1 S -- City: Miami Shores County: Miami Dade Zip: 3:31 3 Folio/Parcel #: If —32-DG - b(3 (S?,v Is the Building Historically Designated: Yes NO Flood Zone: CONTRACTOR: Company Name: O R. 1 Address: /OO' 7/ 5 /Be s r City: l( ' .n.1 State: --r--- Zip: 3 /S'? Qualifier Name: Q ( , , . o ( � 72 I 1 ( 2 5 Phone #: 305 P 5'c •/ 7 00 State Certification or Registration #: CC C 0 5, 22' Certificate of Competency #: Contact Phone #: -211'6(1Y 33 1 Email Address: DESIGNER: Architect/Engineer: Phone #: Value of Work for this Permit $ ^^ t`` Sl) Square/Linear Footage of Type of Work: Address 6dilteration ❑ ew Description of Work: 1:14 ft COLOR THROUGH ROOF TILE IS REQUIRED acknowledged by: Submittal Fee $ Permit Fee $ ?rcd CCF $ CO /CC $ Scanning Fee $ Radon Fee $ DBPR $ Bond $ Notary $ Training/Education Fee $ Technology Fee $ Double Fee $ Structural Review $ TOTAL FEE NOW DUE Qc a ° fl Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature Ow er or Agent Contractor The foregoing instrument was acknowledged before me this 1 The foregoing instrument was acknowledged before me this l'"' / rr�� y C. VIC °t%d E7: , day of it —[ 1 ( , 20 l , by �_9-'t301 , 1, 1 fl day of Pte- ��( 20 C I b � �- • who is personally known to me or who has produced who is personally known to me or who has produced As identification and who did take an oath. NOTARY PUBIC: NOTARY 114,W: ,(" 1 \ I Si 1 � Sign: (;' -- . \( Print: Il as identification and who did take an oath. LIBERTAD VELA - PULLS MY COMMISSION # DD791650 ' �licorr EXPIRES: May 26.2012 I.E90.J.NOTARY R. Mary Dispasal Asap. Co. Print: • My Commission Expires: H O1_ N6 LIBERTAD VEGA - PULLES MY COMMISSION # DD7916$0 EXPIRES: May 26, 2012 1.000.34.10TARY I7. Neon' Mamlm%Alm. OS. My Commission Expires: V( W`A APPROVED BY 21 6/ �� Plans Examiner Zoning Structural Review Clerk (Revised 07 /10 /07)(Revised 06 /10 /2009)(Revised 3/1 5/09)(rev6/4/1 0) Miami Shores Viiiage Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 OWNERS'S AFFIDAVIT OF EXEMPTION ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR EXISTING SITE - BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES PERSUANT TO SECTION 553.844 F.S. To: Miami Shores Village Building Department 10050 NE 2nd Ave Miami Shores, Fl 33138 Re: Owner's Name: Property Address: Roofing Permit Number: Dear Building Official: 1 /( i--\)c, ��7 certify that I am not required to retrofit the roof to wall connections of my building because: ipThe just valuation for the structure for purpose of ad valorem taxation is less than $300,000.00. Please attach proof of ad valorem taxation. ❑ The building was constructed in compliance with the provisions of the Florida Building Code (FBC) or with the provisions of 1994 edition of the South Florida Building Code (1994 SFBC) Signature Print Name State of Florida County of Dade The undersigned, being the first duly sworn, deposes and says that he/she is the owner for the above property mentioned. Swom to and subscribed before me this ) day of . '� ���� LA, Notary Public, Sate of Florida at Large . NN LIBERTAD VEGA- PULLES MY COMMISSION # DD791690 � WIRES: May 26, 2012 r y 11.NeeryB i1AMa.CO. • When the just valuation of the structure for purpose of ad valorem taxation is equal to or more than $300,000.00, and the building was not constructed with FBC nor a 1994 SFBC. Then you must provide a building application from a General Contractor for the Roof to Wall connection Hurricane Mitigation. Revised on 5/21/2009 ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Florida Building Code Edition 2007 High - Velocity Hurricane Zone Uniform Permit Application Form. .Spr_tion A (General Information) JU:4 0 7X011 Master Permit No. Process No. ob dres ame A-C 0 Ispha ❑ Metal Panel /Shingles ❑ Wood Shingles /Shakes hingles ope 6u -5°.a ❑ Mechanically Fastened Tile Mortar /Adhesive Set Tile ❑ New Roof ❑ Prescriptive BUR -RAS 150 ROOF TYPE 5ZLReroofing ❑ Recovering ❑ Repair ❑ Maintenance ROOF SYSTEM INFORMATION Low Slope Roof Area (SF) Steep Sloped Roof Area (SF) Total (SF) uo (°16 -- Section R (Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. ■■■ ■■■■ •11•11•■•■■■■■■■■■■■ ■■■■■■■■■■■■ �i 1I ■1■ •■■ •■ ■ ■•■ ■ ■■■■■■ ■ ■■ ■•■1 ■ ■1 ■11 ■■ ■■■1111■ ■ ■�7i ■11 ■7 ■■■■■I1■1I ■ ■ ■ ■ ■ ■ ■ ■■ ■.lTM i_ i« iumu■! ■■111 ! ■11■■ ■- imazu EEIPEE -11111111 11 r ■ ■ ■■■ MIME REMNIIIIIN ■E3ZZEGZ 11 • ■ ■111mum" min 111 11 ■■■ ■■ II WPM ■ IIM■ ■i11i ■■■■ ■:.....ttte --- r— .lii.=•-.1111 ■■ ■■11 ■■ ■■ ■ MrIrrE M. .MM' ■ ■ ■1111■!'- 'I■ ■ ■ ■■ `mo lmomm ■■ moiMEM A:■ ■ ■ ■■ ■■ FLORIDA BUILDING CODE — BUILDING ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Florida Building Code Edition 2007 High - Velocity Hurricane Zone Uniform Permit Application Form. Section C (Low Slope Application) Fill in specific roof assembly components and identify manufacturer (If a component is not used, Identify as "NA ") System Manufacturer: Product Approval No.: Design Wind Pressures, From RAS 128 or Calculations: Pmax1: Pmax2: Pmax3: Max. Design Pressure, from the specific Product Approval system: Deck: Type: Gauge/Thickness: Slope: Anchor/Base Sheet No of Ply(s): Anchor/Base Sheet Fastener/Bonding Material: Insulation Base Layer. Base Insulation Size and Thickness: Base Insulation Fastener/Bonding Material: Top Insulation Layer: Top Insulation Size and Thickness: Top Insulation Fastener/Bonding Material: Base Sheet(s) & No. of Ply(s): Base Sheet Fastener/Bonding Material: Ply Sheet(s) & No. of Ply(s): PIy Sheet Fastener /Bonding Material: Top Pty: Top PIy FastenerBonding Material: FLORIDA BUILDING CODE — BUILDING Surfacing: Fastener Spacing for Anchor/Base Sheet Attachment: Field: " oc @ Lap, # Rows @ " oc Perimeter " oc @ Lap, # Rows _ @ " oc Corner: " oc @ Lap, it Rows @ " oc Number of Fasteners Per Insulation Board: Field Perimeter Corner Illustrate Components Noted and Details as Applicable: Woodblocking, Gutter, Edge Termination, Stripping, Flashing, Continuous Cleat, Cant Strip, Base Flashing, Counter - Flashing, Coping, Etc. Indicate: Mean Roof Height, Parapet Height, Height of Base Flashing, Component Material, Material Thickness, Fastener Type, Fastener Spacing or Submit • FT FT Parapet Height Mean Roof Height ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Florida Building Code Edition 2007 High- Velocity Hurricane Zone Uniform Permit Application Form. Ser_tinn D (Steep SInped Rnnf System) Roof System Manufacturer: _ Notice of Acceptance Number: - . r ,[ -) ,, Q d Minimum Design Wind Pressures, If Applicable (From RAS 127 or Calculations): 1: P2: �n , .. P3: d I+ 0-1 Maximum Design Pressure (From the Product Approval Specific System): d e Roof Slope: 12 Steep Slnped Ronf Syctpm flesr_rintion \ Deck Type: tr,f '�s� `: ? _- V Vie, Type Underlayment: Insulation: Fire Barrier: Ridge Ventilation? Mean Roof Height: a `' h` V r` u Fastener Type & Spacing: Adhesive Type: S e(-6 fl c) Type Cap Sheet: Roof Covering: Type & Size Drip Edge: iw�5 Y iIs 3 X °3 j FLORIDA BUILDING CODE — BUILDING ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Florida Building Code Edition 2007 High- Velocity Hurricane Zone Uniform Permit Application Form. SeCt1An E /T erect r ulatinncr For Moment based file systems, choose either Method l or 2. Compare the values for Mr with the values from Mf. if the Mf values are greater than or equal to the Mr values, for each area of the roof, then the tile attachment method is acceptable. Method 1 "Moment Based Tile Calculations Perj RAS 127" p .2®� c �. li i .t.� 1 �C-d' .9 (P1: x 2 Mg: S. = Mrl Product Approval Mf 7 (P2: IS' x X _ 64- Mg: 11 i = Mr2 60• 34i Product Approval Mf ( 3 . g - M g . ' ` = M V • Product Approval Mf 0 �� r Method 2 "Simplified Tile Calculations Per Table Below" Required Moment of Resistance (Mr) From Table Below Product Approval Mf Mean Roof Height -0, Roof Slope 15' M, reguired Moment Resistance* 20' 26' 30' 40' 2:12 34.4 38.5 38.2 39.7 42.2 3:12 32.2 34.4 38.0 37.4 39.8 4:12 30.4 32.2 33.8 35.1 37.3 5:12 28.4 30.1 31.6 32.8 34.9 6:12 26.4 28.0 29.4 30.5 32A 7:12 24.4 26.9 27.1 28.2 30.0 'Must be used in conjunction with a list of moment based tile systems endorsed by the Broward County Board of Rules and Appeals. For Uplift based the systems use Method 3. Compared the values for F with the values for Fr. If the F values are greater than or equal to the Fr values, for each area of the roof, then the file attachment method is acceptable. Method 3 "Moment Based Tile Calculations Per RAS 127" (Pi' x L = - x w: = ) - W: x cos 8 = Fri Product Approval F' (P2: x L = - x w: = _) - W: x cos 0 = Fr2 Product Approval F' (P g: x L = x w: = J - W: x cos 0 = F r Product Approval F Where to Obtain information Description Symbol Where to find Design Pressure PI or P2 or P3 RAS 127 Table 1 or by an engineering analysis prepared by PE based on ASCE 7 Mean Roof Height H Job Site Roof Slope 0 Job Site Aerodynamic Multiplier x Product Approval Restoring Moment due to Gravity 1N8 Product Approval Attachment Resistance Mf Product Approval Required Moment Resistance Mg Calculated Minimum Attachment Resistance F Product Approval Required Uplift Resistance Fr Calculated Average Tile Weight W Product Approval Tile Dimensions L = length W = width Product Approval All calculations must be submitted to the building official at the time of permit application. FLORIDA BUILDING CODE - BUILDING Owner's Notification Form 07 MIAMM COUNTY "Delivering Excellence Every Day" SECTION 1524 HIGH VELOCITY HURRICANE ZONES- REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS 1524.1 Scope. As it pertains to this section, it is the responsibility of the roofmg contractor to provide the owner with the required roofing permit, and to explain to the owner the content of this section. The provisions of Chapter 15 of the Florida Building Code, Building govem the minimum requirements and standards of the industry for roofing system installations. Additionally, the following items should be addressed as part of the agreement between the owner and the contractor. The owner's initial in the designated space indicates that the item has been explained. 1. Aesthetics - workmanship: The workmanship provisions of Chapter 15 (High Velocity Hurricane Zone) are for the purpose of providing that the roofing system meets the wind resistance and water intrusion performance standards. Aesthetics (appearance) are not a consideration with respect to workmanship provisions. Aesthetic issues such as color or architectural appearance, that are not part of a zoning code, should be addressed as part of the agreement between the owner and the contractor. 2. Renailing wood decks: When replacing roofing, the existing wood roof deck may have to be renailed in accordance with the current provisions of Chapter 16 (High Velocity Hurricane Zones) of the Florida Building Code. (The roof deck is usually concealed prior to removing the existing roof system). 3. Common roofs: Common roofs are those which have no visible delineation between neighboring units (i.e. townhouses, condominiums, etc.). In buildings with common roofs, the roofmg contractor and/or owner should notify the occupants of adjacent units of roofmg work to be performed. 4. Exposed ceilings: Exposed, open beam ceilings are where the underside of the roof decking can be viewed from below. The owner may wish to maintain the architectural appearance; therefore, roofmg nail penetrations of the underside of the decking may not be acceptable. The owner provides the option of maintaining this appearance. 5. Ponding water: The current roof system and/or deck of the building may not drain well and may cause water to pond (accumulate) in low -lying areas of the roof. Ponding can be an indication of structural distress and may require the review of a professional structural engineer. Ponding may shorten the life expectancy and performance of the new roofmg system. Ponding conditions may not be evident until the original roofing system is removed. Ponding conditions should be corrected. 6. Overflow scuppers (wall outlets): It is required that rainwater flow off so that the roof is not overloaded from a build up of water. Perimeter /edge walls or other roof extensions may block this discharge if overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in accordance with the requirements of: Chapter 15 and 16 herein and the Florida Building Code, Plumbing. 4't7. Ventilation: Most roof structures should have some ability to vent natural airflow through the interior of the structural assembly (the building itself). The existing amount of attic ventilation shall not be reduced. Exception: Attic spaces, designed by a Florida- licensed engineer or registered architect to eliminate the attic venting, venting shall not be re • uired. pv Owner's /Agent's Signature: Contractor's Signature: Property Address: Date: Permit Number: Ne ( T BUILDING CODE COMPLIANCE OFFICE (BCCO) PRODUCT CONTROL DIVISION NOTICE OF ACCEPTANCE (NOA) etiih� 200 Story Road Lake Wales, FL 33898 MIAMI -DADE COUNTY, FLORIDA METRO -DADE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 MIAMI, FLORIDA 33130 -1563 (305) 375 -2901 FAX (305) 375 -2908 SCOPE: This NOA is. being issued under the applicable rules M am Dade County Product Control Diconstruction n and accepted The documentation submitted has been review by and other areas where allowed by by the Board of Rules and Appeals (BORA) to be used in Miami Dade County the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product the t0 Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or County Product Control Division Oth reserves the this product or to revoke this acceptance, if it is determined by Miami-Dade C material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: LABELING: Each unit shall bear a permanent label with the manufac carer' a e or logo, city, ee and following statement: "Miami -Dade County Product P p unless noted hs i RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiraoM� use of this NOA as an endorsement of angy'm the materials, use, and/or manufacture of the product or process. product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to, comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, NOA is displayed, and,followed theo it shall the expiration date may be displayed in advertising liters any portion be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This revises NOA #07- 1023.12 and consists of pages 1 through 7. The submitted documentation was reviewed by Alex Tigera. Approval Date: 05/27/09 Page 1 of 7 ROOFING ASSEMBLY APPROVAL Category: Sub- Category: Material: Roofmg Flat Profile Roofmg Tiles Concrete 1. SCOPE This renews a system using Monier Lifetile Atlantis Shake & Slate Concrete Roof Tile, as manufactured Monier Lifetile LLC in Pompano Beach, FL and described in Section 2 of this Notice of Acceptance. For locations where the pressure requirements, as determined by applicable Building Code d oes not exceed the design pressure values obtained by calculations in compliance with RAS 127 using the values listed in section 4 herein. The attachment calculations shall be done as a moment based system. 2. PRODUCT DESCRIPTION Manufactured by Test Applicant Dimensions Specifications Monier Lifetile Atlantis Shake and Slate Tile Trim Pieces 1= 16" w = 10" 1'/4 "thick 1 =varies w = varies varying thickness 2.1 SUBMITTED EVIDENCE: Test Agency Redland Technologies The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. TAS 112 TAS 112 Test Identifier 7161 -03 Appendix III 94 -060A 94 -084 25- 7094 -2 25- 7094 -8 25- 7094 -5 Product Description Flat, interlocking, high pressure extruded concrete shake and slate roof tile equipped with two nail holes. For direct deck, mortar or adhesive set applications. Accessory trim, concrete roof pieces for use at hips, rakes, ridges and valley terminations. Manufactured for each tile profile. Test Name/Report Static Uplift Testing PA 102 & PA 102(A) Static Uplift Testing PA 101 (Mortar Set) (Adhesive Set) Static Uplift Testing PA 102 (4" Headlap, Nails, Direct Deck, New Construction) Static Uplift Testing PA 102 (4" Headlap, Nails, Battens) Static Uplift Testing PA 102 (4" Headlap, Nails, Direct Deck, Recover/Reroof) Date Dec. 1991 March, 1994 May 1994 Oct. 1994 Oct. 1994 Oct. 1994 NOA No.: 09- 0422.11 Expiration Date: 12/16/12 Approval Date: 05/27/09 Page 2 of 7 Test Agency The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. Redland Technologies Redland Technologies Redland Technologies Redland Technologies The Center for Applied Engineering, Inc. Professional Service Industries, Inc. Celotex Corporation Testing Service Walker Engineering, Inc. Walker Engineering, Inc. Walker Engineering, Inc. Walker Engineering, Inc. Walker Engineering, Inc. Walker Engineering, Inc. Walker Engineering, Inc. Walker Engineering, Inc. Nutting Engineerins Nutting Engineerins Test Identifier 25- 7183 -6 25- 7183 -5 25- 7214 -1 25- 7214 -5 7161 -03 Appendix II Letter Dated Aug. 1, 1994 P0631 -01 P0402 Project No. 307025 Test #MDC -77 224 -47099 520109 -1 520111 -4 520191 -1 Calculations Calculations Calculations Calculations Calculations Calculations Calculations Calculations TAS -112 TAS -112 Test Name/Report Static Uplift Testing PA 102 (2 Quik -Drive Screws, Direct Deck) Static Uplift Testing PA 102 (2 Quik -Drive Screws, Battens) Static Uplift Testing PA 102 (1 Quik -Drive Screw, Direct Deck) Static Uplift Testing PA 102 (1 Quik -Drive Screw, Battens) Wind Tunnel Testing PA 108 (Nail -On) Wind Tunnel Testing PA 108 (Nail -On) Wind Tunnel Testing PA 108 (Mortar Set) Withdrawal Resistance Testing of screw vs. smooth shank nails Wind Driven Rain PA 100 Physical Properties PA 112 Static Uplift Testing PA 101 Aerodynamic Multiplier Moment of Gravity 25 -7094 25 -7496 25 -7584 25- 7804b -8 25- 78044 & 5 25- 7848 -6 25 -7183 Aerodynamic Multipliers Two Patty Adhesive Set System 13343.1 13343.1 Date Feb. 1995 Feb. 1995 March, 1995 March, 1995 Dec. 1991 Aug. 1994 July 1994 Sept. 1993 Oct. 1994 Sept. 1994 Dec. 1998 March 1999 October 2007 August 2007 February 1996 April 1996 December 1996 March 1995 April 1999 April 1999 June 2007 March 2009 NOA No.: 09- 0422.11 Expiration Date: 12/16/12 Approval Date: 05/27/09 Page 3 of 7 3. LIMITATIONS 3.1 Fire classification is not part of this acceptance. 3.2 For mortar or adhesive set tile applications, a static field uplift test shall be performed in accordance with RAS 106. 3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test in accordance with TAS 112, appendix `A'. Such testing shall be submitted to the Building Code Compliance Office for review. 3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed section 4.1 herein. 3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature. 3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with applicable building code. 3.7 May be installed on slopes 7:12 and greater with a minimum of two screws. 4. INSTALLATION 4.1 Monier Lifetile Atlantis Shake and Slate Concrete Roof Tile and its components shall be installed in strict compliance with Roofing Application Standard RAS 118, RAS 119, and RAS 120. 4.2 Data For Attachment Calculations . aoie 1: Average Weight (W) and Dimensions (I x w ) Tile Profile Weight -W (lbf) Length -I (ft) Width -w (ft) Monier Lifetile Atlantis Shake & Slate Tile 8.5 1.33 0.833 Tile Profile Table 2: Aerodynamic Multipliers - a, ft3 (ft3) Batten Application & Slate Tile N/A Monier Lifetile Atlantis Shake (ft3) Direct "a-Application Tile Profile Monier Lifetile Atlantis Shake & Slate Tile 2 ":12" Battens Table 3: Restoring Moments due to Gravity - M, (ft-Ibf) 3 ":12" Direct Deck Battens 5 ":12" 6 ":12" Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck 7 ":12" or greater Battens Direct Deck N/A 6.17 N/A 6.11 N/A N/A 5.89 N/A 5.75 N/A 5.59 NOA No.: 09- 0422.11 Expiration Date: 12/16/12 Approval Date: 05/27/09 Page 4 of 7 Table 4: Attachment Resistance Expressed as a Moment - Mf (ft -Ibf) for Nail-On Systems Tile Profile Fastener Type Direct Deck (min 15/32" plywood) Direct Deck (min. 19/32" plywood) Battens Monier Lifetile Atlantis Shake & Slate Tile 2 -10d Ring Shank Nails 30.9 38.1 N/A 1 -10d Smooth or Screw Shank Nail 7.3 9.8 N/A 2 -10d Smooth or Screw Shank Nails 14.0 18.8 N/A 1 #8 Screw 30.8 30.8 N/A 2 #8 Screw 51.7 51.7 N/A 1 -10d Smooth or Screw Shank Nail (Field Clip) 24.3 24.3 N/A 1 -10d Smooth or Screw Shank Nail (Eave Clip) 19.0 19.0 NIA 2 -10d Smooth or Screw Shank Nails (Field Clip) 35.5 35.5 N/A 2 -10d Smooth or Screw Shank Nails (Eave Clip) 31.9 31.9 N/A Table 5: Attachment Resistance Expressed as a Moment Mf (ft-Ibf) for Two Patty Adhesive Set Systems Tile Profile - Tile Application Minimum Attachment Resistance Monier Lifetile Atlantis Shake & Slate Tile Adhesive' 31.3` 1 See manufactures component approval for installation requirements. 2 Flexible Products Company TileBond Average weight per patty 13.9 grams. Polyfoam Product, Inc. Average weight per patty 8 grams. Table 5A: Attachment Resistance for Single Patty Expressed as a Moment - Mt (ft -Ibf) Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Res Monier Lifetile Atlantis Shake & Slate Tile Pol Pro TM 5 See specific mortar manufacturers Notice of Acceptance ° ^ PolyProT'" C___ 4074' 3 Large paddy placement of 45 grams of PolyProTM. 4 Medium paddy placement of 24 grams of PolyProTM. Table 5B: Attachment Resistance Expressed as a Moment - Mf (ft -ibf) for Mortar or Adhesive Set Systems Tile Profile Tile Application Attachment Resistance Monier Lifetile Atlantis Shake & Slate Tile Mortar Setb 39.0 5 See specific mortar manufacturers Notice of Acceptance NOA No.: 09- 0422.11 Expiration Date: 12/16/12 Approval Date: 05/27/09 Page 5 of 7 5. LABELING All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo, or following statement: "Miami -Dade County Product Control Approved ". MONIER LIFETILE LLC, ATLANTIS SHAKE AND SLATE (POMPANO BEACH, FL PLANT) LOCATED UNDERNEATH TILE 6. BUILDING PERMIT REQUIREMENTS 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance. 6.1.2 Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this system. NOA No.: 09 -0422.11 Expiration Date: 12/16/12 Approval Date: 05/27/09 Page 6 of 7 PROFILE DRAWINGS . 1112" -••• • •.„.. INRIERLOCIC ...,,,. ....-.<:: 16i/6 -:--:-----.:..-:-... --. " ....... r.„:-.....--z-,.. -... --........ ---.., ......., ' • •-•'.'...--. --. -.... . . ., •, -,::"..... `".--.. -:--- '-'---. ‘......::-..,.---..:-, -...„ -.:.-.. 441 ..... „,.... .-......., . ...... .-...:-1 MORAY..„,...„........ -.... -..;:z..„,. ... <='0 ) •-•.* • MONIER LIFETILE ATLANTIS SHAKE & SLATE CONCRETE ROOF TILE END OF THIS ACCEPTANCE NOA No.: 09-0422.11 Expiration Date: 12/16/12 Approval Date: 05/27/09 Page 7 of 7 MIA M MDADE BUILDING CODE COMPLIANCE OFFICE (BCCO) PRODUCT CONTROL DIVISION NOTICE OF ACCEPTANCE (NOA) Polyglass USA Inc. 150 Lyon Drive Fernley, NV 89408 MIAMI -DADE COUNTY, FLORIDA METRO -DADE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 MIAMI, FLORIDA 33130 -1563 (305) 375 -2901 FAX. (305) 375 -2908 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by Miami -Dade County Product Control Division and accepted by the Board of Rules and Appeals (BORA) to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). his NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Division that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code and the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Polystick MTS, IR Xe, TU, TU Plus and TU Polyester LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA No.07- 1025.10 and consists of pages 1 through 6. The submitted documentation was reviewed by Jorge L. Acebo. NOA No.: 08- 0929.03 Expiration Date: 09 /13/11 Approval Date: 01/08/09 Page 1 of 6 ROOFING COMPONENT APPROVAL Category: Sub- Category: Material: PRODUCTS DESCRIPTION: Product Polystick MTS underlayment Manufacturing Location #2 Polystick IR-Xe underlayment Manufacturing Location #1 & #2 Polystick TU underlayment Manufacturing Location #1 Polystick TU Plus underlayment (Facer of Membrane Labeled in Orange or Black Ink) Manufacturing Location #1 & #2 Polystick TU Polyester Manufacturing Location #3 Roofing Underlayment SBS , APP Self- Adhering Modified Bitumen Dimensions Roll: 65'8" x 3'33/8" 60 mils thick Roll: 65'8" x 3'33/8" 80 mils thick Roll: 32'10" x 3'3-3/8" 100 mils thick Roll: 65'8" x 3'3-3/8" 80 mils thick Roll: 32'10" x 3'3 -3/8" 130 mils thick Test Specification TAS 103 TAS 103 and ASTM D 1970 TAS 103 and ASTM D 1970 TAS 103 and ASTM D 1970 TAS 103 MANUFACTURING PLANTS: 1. 555 Oakridge Road, Hazelton, PA 2. 621 Sniveley Avenue, Winter Haven, FL 3. 150 Lyon Drive, Fernley, NV Product Description A homogeneous, rubberized asphalt waterproofing membrane, glass fiber reinforced with polyolefinic film on the upper surface for use as an underlayment for metal roofing, roof tile, slate tiles and shingle underlayment. A fine granular /sand top surface self - adhering, APP polymer modified, fiberglass reinforced, bituminous sheet material for use as an underlayment in sloped roof assemblies. Designed as an ice & rain shield and as a flat roof tile underlayment. A heavy granuled surface self adhering, APP polymer modified, fiberglass or polyester reinforced, bituminous sheet material for use as an underlayment in sloped roof assemblies. Designed as a a roof tile underlayment. A non - wicking fabric surfaced, self-adhering, APP polymer modified, fiberglass reinforced with a high strength polyester fabric, bituminous sheet material for use an an underlayment in sloped roof assemblies. Designed as a metal roofing and roof tile underlayment. A rubberized asphalt waterproofmg membrane, glass- fiber /polyester reinforced, with a granular surface designed for use as a tile roof underlayment. NOA No.: 08-0929.03 Expiration Date: 09/13/11 Approval Date: 01/08/09 Page 2 of 6 EVIDENCE SUBMITTED: Test A2encv Exterior Research & Design, LLC Trinity I ERD PRI Asphalt Technologies Momentum Technologies, Inc. Test Identifier #11756.04.01 -1 #11756.08.01 -1 #02202.08.05 #P5110.08.07 P10870.09.08 -R1 PR101111 PUSA- 005 -02 -01 PUSA - 018 -02 -01 PUSA- 035 -02 -01 PUSA- 033 -02 -01 PUSA- 055 -02 -02 PUSA- 083 -02 -01 JX20H7A Test Name/Report Date TAS 103 04/27/01 ASTM D 1970 08/14/01 TAS 103 08/29/05 TAS 103 08/29/07 TAS 103 12/04/08 ASTM D 4977 04/08/02 ASTM D 4977 01/31/02 ASTM D 2523 07/14/03 TAS 103 09/29/06 ASTM D 1970 01/12/06 TAS 103 -95 12/10/07 TAS 103 -95 06/30/08 ASTM D 4798 /ASTM G 155 04/01/08 INSTALLATION PROCEDURES: Deck Type 1: Wood, non - insulated Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626 or Polyprotector UDL or Polyprotector UDL AS. Fastening: Nails and tin caps 12" grid, 6" o.c. at laps. (for base sheet only) Membrane: Polystick membranes self- adhered. Surfacing: None 1. All nails in the deck shall be carefully checked for protruding heads. Re- fasten any loose decking panels, and sweep the deck thoroughly to remove any dust and debris prior to application. 2. Place the underlayment over metal drip edge in accordance with RAS 111. 3. Place the first course of membrane parallel to the eave, rolling the membrane to obtain maximum contact. Remove the release film as the membrane is applied. . All side laps shall be a minimum of 3%2" and end laps shall be a minimum of 6." Roll the membrane into place after removing the release strip. Vertical strapping of the roof with Polystick is acceptable. Membrane shall be back nailed in accordance with applicable building code. 4. When applying the membrane in the valley, start at the low point and work to the high point, rolling the membrane from the center outward in both directions. 5. For ridge applications, center the membrane and roll from the center outward in both directions. 6. Roll or broom the entire membrane surface so as to have full contact with the surface, giving special attention to lap areas. 7. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control Notice of Acceptance. 8. All protrusions or drains shall be initially taped with a 6" piece of underlayment. The flashing tape shall be pressed in place and formed around the protrusion to ensure a tight fit. A second layer of Polystick shall be applied over the underlayment. NOA No.: 08-0929.03 Expiration Date: 09/13/11 Approval Date: 01/08/09 Page 3 of 6 GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance. 2. Polystick MTS and TU Plus may be used in asphaltic shingles, wood shakes and shingles, non- structural metal roofing, roof tile systems and quarry slate roof assemblies. IR -Xe, TU, and TU Polyester may be used in all the previous assemblies listed except metal roofing. 3. Deck requirements shall be in compliance with applicable building code. 4. Polystick membranes shall be applied to a smooth, clean and dry surface. The deck shall be free of irregularities. 5. Polystick membranes shall not be adhered directly over a pre - existing roof membrane as a recover system. 6. All Polystick MTS, IR -Xe, TU, TU Polyester and TU Plus (manufactured in Winter Haven, FL Plant) shall not be left exposed as a temporary roof for longer than 30 days after application. Polystick TU Pl us(manufactured in Hazelton, PA Plant) shall not be left exposed as a temporary roof for longer than 180 days after application. Polyglass reserves the right to revise or alter product exposure times; not to exceed the preceeding maximum time limitations. 7. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9B -72 of the Florida Administrative Code. 8. In roof tile application, data for the attachment resistance of roof tiles shall be as set forth in the roof tile manufacturer's Notice of Acceptance. Polystick TU and TU Plus may be used in both adhesive set and mechanically fastened roof file applications. Polystick IR -Xe is limited to mechanically fastened roof tile applications. Polystick MTS is limited to mechanically fastened with battens roof tile applications. Polystick TU Polyester may be used in both adhesive set and mechanically fastened roof file applications with the exception of mortar set tile applications. 9. The maximum roof slope for use as roof tile underlayment for (direct- to-deck) tile assemblies shall be as follows: (See Table Below) Tile Profile Polystick MTS Polystick 1R -Xe Polystick TU, TU Plus TU Polyester No limitation Flat Tile Prohibited without battens 5:12 Profiled Tile Prohibited without battens Prohibited No limitation The above slope limitations can be exceeded only by using battens and counter battens in accordance with the Approved Tile System Notice of Acceptance and applicable Florida Building Code requirements. Polystick MTS shall not be used in direct -to -deck applications. Battens are required for both loading and installation of tiles at all times. 10. Care should be taken during the loading procedure to keep foot traffic to a minimum and to avoid dropping of file directly on the underlayment. Refer to Polyglass' Tile loading detail below for loading procedure for all underlayments except Polystick MTS which shall be loaded onto battens. 6 Roofing Tiles (6 Max. Per Stack) 12 NOA No.: 08- 0929.03 Expiration Date: 09/13/11 Approval Date: 01/08/09 Page 4 of 6 11. Refer to prepared roofmg system Product Control Notice of Acceptance for listed approval of this product with specific prepared roofing products. Polystick MTS, IR -Xe, TU, TU Plus and TU Polyester may be used with any approved roof covering Notice of Acceptance listing Polystick MTS, 1R-Xe, TU, TU Plus and TU Polyester as a component part of an assembly in the Notice of Acceptance. If Polystick MTS, IR -Xe, TU, TU Plus and TU Polyester is not listed, a request may be made to the Authority Having Jurisdiction (AHJ) or the Miami -Dade County Product Control Department for approval provided that appropriate documentation is provided to detail compatibility of the products, wind uplift resistance, and fire testing results. LABELING: 1. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city and state of manufacturing facility and the following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade County Product Control Seal as shown below. BUILDING PERMIT REQUIREMENTS: Application for building permit shall be accompanied by copies of the following: 1. This Notice of Acceptance. 2. Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this materials. POLYGLASS GENERAL APPLICATION GUIDELINES FOR POLYSTICK MEMBRANES: 1. Polyglass does accept the direct application of Polystick underlayment membranes to wood decks. Installers are cautioned to refer to applicable local building codes prior to direct deck installation to ensure this is acceptable. Please also refer to applicable Product Data Sheets of the corresponding products. 2. All rolls, with the exception of Polystick TU Plus should be back - nailed in selvage edge seam as per Polyglass Back Nailing Guide. Nails shall be, 11 gauge ring shank type, applied with a minimum 1" metal disk as required m Dade County or simplex type nail as otherwise allowable in other regions, at a minimum rate of 12" o.c. Polystick TU Plus should be back nailed in designated area marked "nail area, area para clavar" on the face of membrane, with the above stated nails and/or disks. The head lap membrane is to cover the area being back - nailed. (Please refer to applicable local building codes prior to installation.) 3. All seal lap seams (selvage laps) must be rolled with a hand roller to ensure full contact. 4. All fabric over fabric; and granule over granule end laps, shall have a 6" wide, uniform layer of Polyglass Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, Polyglass PG500 MB Flashing Cement, Mule -Hide 241 Premium Modified Flashing Cement, Mule -Hide 251 Premium Wet/Dry Elastomeric Flashing Cement, or Mule -Hide 421 Mod Bit Flashing Adhesive Trowel Grade mastic, applied in between the application of the lap. The use of mastic between the laps does not apply to Polystick MTS. 5. A maximum of 6 tiles per stack are allowed when loading tile on the underlayments. Refer to the Polyglass Tile Loading Guidelines. See General Limitations #9 and #10. NOA No.: 08-0929.03 Expiration Date: 09 /13/11 Approval Date: 01/08/09 Page 5 of 6 6. Battens and/or Counter - battens, as required by the tile manufacturers NOA's, must be used on all projects for pitch/slopes of 7 "/12" or greater. It is suggested that on pitch/slopes in excess of 6 1/4 "112 ", precautions should be taken, such as the use of battens to prevent tile sliding during the loading process. 7. Minimum cure time after membrane installation & before loading of roofing tiles is Forty-Eight (48) Hours. 8. Polystick membranes may not be used in any exposed application such as crickets, exposed valleys, or exposed roof to wall details. 9. Repair of Polystick membranes is to be accomplished by applying Polyglass Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, Polyglass PG500 MB Flashing Cement, Mule -Hide 241 Premium Modified Flashing Cement, Mule -Hide 251 Premium Wet/Dry Elastomeric Flashing Cement, or Mule -Hide 421 Mod Bit Flashing Adhesive Trowel Grade mastic to the area in need of repair, followed by a patch of the Polystick material of like kind should be set and hand rolled in place over the area needing such repair. Patching membrane shall be a minimum of 6 inches in either direction. The repair should be installed in such a way so that water will run parallel to or over the top of all laps of the patch. 10. All self - adhered membranes must be rolled to ensure full contact with approved substrates. Polyglass requires a minimum of 40 lbs for a weighted roller for the rolling of the field membrane. Hand rollers are acceptable for rolling of patches or small areas of the roof. Brooming may be used where slope prohibits rolling. 11. All approved substrates should be dry, clean and properly prepared, before any application of Polystick membranes commences. An approved substrate technical bulletin can be furnished upon request. It is recommended to refer to applicable building codes prior to installation to verify acceptable substrates. 12. The Polyglass Miami -Dade Notice of Acceptance (NOA) approval for Polystick membranes and PolyProtector UDL.can be furnished upon request by our Technical Services Department by calling 1 (800) 894 -4563. 13. Polyglass offers a 10 year Limited Material Warranty on all properly installed Polystick self - adhered underlayments. Warranty must be requested and registered by Polyglass to be in force. 14. Questions in regards to the application of Polyglass products should be directed to our Technical Services Department at 1 (800) 894 -4563. 15. Polyglass recommends that applicators follow good roofing practices and applicable procedures as outlined by the National Roofing Contractors Association (NRCA). PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF SPECIFIC APPLICATIONS. LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS AND RECOMMENDATIONS. END OF THIS ACCEPTANCE NOA No.: 08- 0929.03 Expiration Date: 09/13/11 Approval Date: 01/08/09 Page 6 of 6 MIAMNDiADE COUNTY BUILDING AND NEIGHBORHOOD COMPLIANCE DEPARTMENT (BNC) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NOA) Polyfoam Products, Inc. 11715 Boudreaux Road Tomball, TX 77375 MIAMI -DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175 -2474 T (786) 315 -2590 F (786) 315 -2599 www.miamidade.eov /building/ SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County BNC - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BNC reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Polypro® A11160 LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This renews NOA# 06- 0201.02 and consists of pages 1 through 7. The submitted documentation was reviewed by Alex Tigera. NOA No.: 11- 0124.04 Expiration Date: 05/10/12 Approval Date: 04/14/11 Page 1 of 7 ROOFING COMPONENT APPROVAL: Category: Roofing Sub Category: Roof file adhesive Materials: Polyurethane SCOPE: This approves Polypro® AH160 as manufactured by Polyfoam Products, Inc. as described in Section 2 of this Notice of Acceptance. For the locations where the design pressure requirements, as determined by applicable building code, does not exceed the design pressure values obtained by calculations in compliance with Roofing Application Standard RAS 127, for use with approved flat, low, and high profile roof tiles system using Polypro {? AH 160. Where the attachment calculations are done as a moment based system for single patty placement, and as an uplift based system for double patty systems PRODUCTS MANUFACTURED BY APPLICANT: Product Dimensions Test Product Descrintion Specifications Polypro® AH 160 N/A TAS 101 Two component polyurethane foam adhesive Foampro® RTF1000 N/A Dispensing Equipment ProPack® 30 & 100 N/A Dispensing Equipment PRODUCTS MANUFACTURED BY OTHERS: Any Miami -Dade County Product Control Accepted Roof Tile Assembly having a current NOA which list moment resistance values with the use of Polypro AH160 roof tile adhesive. PHYSICAL PROPERTIES: Property Density Compressive Strength Tensile Strength Water Absorption Moisture Vapor Transmission Dimensional Stability Closed Cell Content Test ASTM D 1622 ASTM D 1621 ASTM D 1623 ASTM D 2127 ASTM E 96 ASTM D 2126 ASTM D 2856 Results 1.6 lbs. /ft 3 18 PSI Parallel to rise 12 PSI Perpendicular to rise 28 PSI Parallel to rise 0.08 Lbs./Ft2 3.1 Perm / Inch +0.07% Volume Change @ -40° F., 2 weeks +6.0% Volume Change @158°F., 100% Humidity, 2 weeks 86% Note: The physical properties listed above are presented as typical average values as determined by accepted ASTM test methods and are subject to normal manufacturing variation. MANMADE 0 MTY APPROVED NOA No.: 11- 0124.04 Expiration Date: 05/10/12 Approval Date: 04/14/11 Page 2 of 7 EVIDENCE SUBMITTED: Test Agency Test Identifier Test Name/Report Date Center for Applied Engineering #94 -060 TAS 101 04/08/94 257818 -1PA TAS 101 12/16/96 25- 7438 -3 SSTD 11 -93 10/25/95 25- 7438 -4 25- 7438 -7 SSTD 11 -93 11/02/95 25 -7492 SSTD 11 -93 12/12/95 Miles Laboratories NB -589 -631 ASTM D 1623 02/01/94 Polymers Division Ramtech Laboratories, Inc. 9637 -92 ASTM E 108 04/30/93 Southwest Research Institute 01- 6743 -011 ASTM E 108 11/16/94 01- 6739- 062b[1] ASTM E 84 01/16/95 Trinity Engineering 7050.02.96 -1 TAS 114 03/14/96 Celotex Corp. Testing Services 528454 -2 -1 TAS 101 10/23/98 528454 -9 -1 528454 -10 -1 520109 -1 TAS 101 12/28/98 520109 -2 520109 -3 520109 -6 520109 -7 520191 -1 TAS 101 03/02/99 520109 -2 -1 LIMITATIONS: 1. Fire classification is not part of this acceptance. Refer to the Prepared Roof Tile Assembly for fire rating. 2. Polyproo AH160 shall solely be used with flat, low, & high tile profiles. 3. Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120. 4. Roof Tile manufactures acquiring acceptance for the use of Polypro® AH160 roof tile adhesive with their tile assemblies shall test in accordance with TAS 101. 5. Roof Tile manufactures acquiring acceptance for the use of HANDI -STICK roof tile adhesive with their tile assemblies shall test in accordance with TAS 101 with section 10.4 as modified herein. F —W 2 F'— MS NOA No.: 11-0124.04 Expiration Date: 05/10/12 Approval Date: 04 /14/11 Page 3 of 7 INSTALLATION: 1. Polypro® AH160 may be used with any roof tile assembly having a current NOA that lists uplift resistance values with the use of Polypro'? AH160. 2. Polypro® AH160 shall be applied in compliance with the Component Application section and the corresponding Placement Details noted herein. The roof file assembly's adhesive attachment with the use of Polypro® AH 160 shall provide sufficient attachment resistance, expressed as an uplift based system, to meet or exceed the uplift resistance determined in compliance with Miami -Dade County Roofmg Application Standards RAS 127. The adhesive attachment data is noted in the roof tile assembly NOA 3. Polypro® AH160 roof tile adhesive and its components shall be installed in accordance with Roofmg Application Standard RAS 120, and Polyfoam Products, Inc. Polypro® AH160 Operating Instruction and Maintenance Booklet. 4. Installation must be by a Factory Trained 'Qualified Applicator' approved and licensed by Polyfoam Products, Inc. Polyfoam Products Inc. shall supply a list of approved applicators to the authority having jurisdiction. 5. Calibration of the Foampro ill dispensing equipment is required before application of any adhesive. The mix ratio between the "A" component and the "B" component shall be maintained between 1.0- 1.15 (A): 1.0 (B). The dispense timer shall be set to deliver 0.0175 to 0.15 pounds per tile as determined at calibration. No other settings shall be approved. 6. Polypro® AH160 shall be applied with Foampro RTF1000 or ProPacko 30 & 100 dispensing equipment only. 7. Polypro® AH160 shall not be exposed permanently to sunlight. 8. Tiles must be adhered in freshly applied adhesive. Tile must be set within 2 to 3 minutes after Polypro® AH160 has been dispensed. 9. Polypro® AH160 placement and minimum patty weight shall be in accordance with the 'Placement Details' herein. Each generic tile profile requires the specific placement noted herein. Table 1: Adhesive Placement For Each Generic Tile Profile Tile Profile Placement Detail Single Paddy Weight Mm. (grams) Two Paddy Weight per paddy Min. (grams) Flat, Low, High Profiles #1 35 N/A High Profile (2 Piece Barrel) #1 17 /side on cap and 34 /pan N/A Flat, Low, High Profiles #2 24 N/A Flat, Low, High Profiles #3 8 LABELING: All Polypro® AH160 containers shall comply with the Standard Conditions listed herein. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or applicable building code in order to property evaluate the installation of this system. NOA No.: 11- 0124.04 Expiration Date: 05/10/12 Approval Date: 04 /14/11 Page 4 of 7 ADHESIVE PLACEMENT DETAIL 1 SINGLE PATTY MIAMIDADE COUNIY APPROVED Optional 2a4's for 1) Plato enough adhesive to achieve 17 to 23 square inches In oontedwilli the pan tllo steep pHsh appications Turn covers upside down. Plate dimly. 1121i. To 11n. From outside edge of MU Mo. Then Install the tira. Underlaymant Nall through plastic tweet top paillon of the eau course ant No Abut Gosecond course of pan tiles. Ensure Gave end of pan and cover Oka ere flush at eava ENO doge Weephate Fascia (medlar shown) Optional PoInt•up Stotts on longludloal edges ol tile NOA No.: 11-0124.04 Expiration Date: 05/10/12 Approval Date: 04/14/11 Page 5 of 7 ADHESIVE PLACEMENT DETAIL 2 SINGLE PATTY MIAMIOADE COU APPROVED NOA No.: 11-0124.04 Expiration Date: 05/10 /12 Approval Date: 04/14/11 Page 6 of 7 ADHESIVE PLACEMENT DETAIL 3 DOUBLE PATTY Nall through plastic cement Paddy (between tile) Paddy (under tile) z 31n. Single Paddy on under - layment Single paddy under the Single paddy on top of tile COMB In. X7In. medium size paddyeava Fascia course only Nall through plastic cement Nall through plastic cement Single paddy under the Underlayment Single paddy between tile 2 In. x 7In. medium aka paddy yave course only 'in.x 3 In. 4In. Single paddy on under• layment Single paddy on top of tile e CCoourrse Fascia Weephole Save closure Drip edge Single paddy between tile iflPiln.x 3 In. Single paddy on underlayment Single paddy on top of tile Eave Course Save Closure 2 In. x 7 In. medium size paddy save course only Fascia END OF THIS ACCEPTANCE NOA No.: 11- 0124.04 Expiration Date: 05/10/12 Approval Date: 04/14/11 Page 7 of 7