Loading...
RF-10-1123Permit Number: RF -6 -10 -1123 J Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Inspection Number: INSP- 148961 Inspection Date: July 18, 2011 Inspector: Bruhn, Norman Owner: SHAKIR, SHAHIDA Job Address: 10290 NE 2 Avenue Miami Shores, FL 33138- Project: <NONE> Contractor: QUALITY ROOFING CONTRACTORS INC Permit Type: Roof Inspection Type: Final Roof Work Classification: Repair Roof Phone Number Parcel Number 1132060131700 Phone: (305)953 -3333 Building Department Comments REPAIR LEAKS ON FRONT OF TILE ROOF Passe d0I/ Inspector Comments CREATED AS REINSPECTION FOR INSP- 146458. Roof repairs done with bull over tiles is not acceptable. new repairs are OK. Total repairs exceed 25% of roof and entire roof must be replaced. NB 60c� Failed Correction Needed Re- Inspection Fee No Additional Inspections can be scheduled re- inspection fee is paid. until July 15, 2011 For Inspections please call: (305)762 -4949 Page 1 of 1 (0103 10 Miami Shores Village ImamV311 Building Department ,JUN k ?MO 10050 N.E.2nd Avenue, Miami Shores, Florida 33 l38 Tel: (305) 795.2204 Fax: (305) 756.8972 I BY: INSPECTION'S PHONE NUMBER: (305) 762.4949 BUILDING PERMIT APPLICATION FBC 20 Permit No. RC r 1 13 Master Permit No. Permit Type: BUILDIN _ ROOFING Owner's Name (Fee Simple Titleholder) Mohammad S . Shaki r Phone ## (3 0 5) 9 6 5— 91 77 Owner's Address 10 2 9 0 N . E . 2nd Avenue City Miami Shores State Fl Zip 33138 Tenant/Lessee Name Phone # Email Job Address (where the work is being done) 1 0 2 9 0 N . E . 2nd Avenue City Miami Shores Village County Miami -Dade FOLIO / PARCEL # 1 1- 3206 -01 3 -1 00 Zip 33138 Is Building Historically Designated YES NO X Flood Zone Contractor's Company Name Quality Roofing Contractor, IRiGite# (305) 953 -3333 Contractor's Address 13 8 0 0 N . W . ' 1st Avenue City Miami, State F1 Zip 331 68 Qualifier Name Carlos Arocho Phone# 786- 367 -2029 State Certificate or Registration No. RC 0 0 5 8 6 2 7 Certificate of Competency No. 0 0 0 01 7 8 8 9 Contact Phone Marylou or Carlos E -mail quailtyroofing88 @yahoo.com Architect/Engineer's Name (if applicable) Phone # Value of Work For this Permit $ 1 . 000.00 Square / Linear Footage Of Work: 1 /2 sq . Type of Work: ❑Addition ❑Alteration ❑New ii] Repair/Replace ❑ Demolition Describe Work: Repair leaks on front of tile roof . ******** * * * * * * * * * * * * * * * * * * * * * * * * * * * * *** Fees * * * * * * * * ** * * * * * * * * ** * * * * * * * * * * * * * * * * * * * * * ** Submittal Fee •OD Permit Fee $ 7a. C' CCF $ J CO /CC $ Notary $ Training/Education Fee $ ®- Technology Fee $ 0.r Scanning $ • OD Radon $ DPBR $ Bond $ Double Fee $ Violation date: Structural Review. $ Total Fee Now Due $ K, d/�'� Jl See Reverse side -* Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COM ENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will notJe approved and a reinspection fee will be charged. Signatures , Owner or Agent The foregoing instrument was acknowledged before me this day of :Lvn.e , 20/ O , by /l o )7 &ii.ipt-Ad c1k'c who is personaellknown to me or who has produced As identification and who did take an oath. NOTARY PUBLIC: Sign: Print: NOTARY PUTRT.I C -S T .- OF FLORIDA My Commission Expires:s'���,�I�`':Commission #00930046 y' Expires: OCT. 10, 2013 BONDED THRII ATLANTIC BONDING CO., INC. APPROVED BY Signature��� — ��� Contractor The foregoing instrument was acknowledged before me this f day of j-6 ,20 /0, by C &-rft,� 70aL9 , who is personally known to me or who has produced as identification and who did take an oath. Plans Examiner Engineer (Revised 07 /10107)(Revised 06/10/2009) NOTARY PUBLIC: Sign: Print: My Commission Expire i 1• ID ryleu H. ' • ' dez Ceremission # ► ) 930046 %, aipirea. OCT. 10, 2013 4 R J Ai`I.A.YTIC BONDING CO.,1NC. Zoning Clerk cheOked SECTION 4402 JUN 2 1 10 HIGH VELOCITY HURRICANE ZONES REQUIRED OWNERS NOTIFICATION FOR RO CONSIDERATIONS 1524.1 As it pertains to this section, it is the responsibility of the roofing contractor to provide the owner with the required roofing permit, and to explain to the owner the content of this section. The •r• ,1&16 of Chapter 44 of the Florida Building Code, Building govern the minimum requiremen `g • industry for roofing system installations. Additionally, the following items should be a•. s.- - r.s rho. F • agreement between the owner and the contractor. The owner's initial in the adjacen !' item has been explained. 1.2 'l. Aesthetics - Workmanship: The workmanship provisions of Chapte • • :ci Hurricane Zone) are for the purpose � ty ) p rpose of providing that the roofing system s• • and water intrusion performance standards. Aesthetics (appearance) ce) issues are , � .r • • respect to workmanship provisions, Aesthetic issues such as color or architectu s , . • .,.; �.. •,;.- that • not part of a zoning code, should be addressed as part of the agreement between the ownc'aila'the • • contractor. • • • • • •• • •••• • • •••• 2. Renailing Wood Decks: When replacing roofing, the existing wood roof deck may have to be iled in accordance with the current provisions of Section R4403 (High Velocity Hurricane Zones) of the Florida Building Code. (The roof deck is usually concealed prior to removing the existing roof system.) 3. Common Roofs: Common roofs are those which have no visible delineation between hboring units (i.e. townhouses, condominiums, etc.) In buildings with common roofs, the roofing contractor and/or owner should notify the occupants of adjacent units of roofing work to be performed. 4. Exposed Ceilings: Exposed, open beam ceilings are where the underside of the roof decking be viewed from below. The owner may wish to maintain the architectural appearance, therefore, roofing enetrations of the underside of the decking may not be acceptable. 5. Ponding Water: The current roof system and/or deck of the building may not drain well and cause water to pond (accumulate) in low -lying areas of the roof. Ponding can be an indication of structural distress and may require the review of a professional structural engineer. Ponding may shorten the life expectancy and performance of the new roofing system. Ponding conditions may not be evident the original roofing system is removed. Ponding conditions should be corrected. 6. Overflow scuppers (wall outlets): It is required that rainwater flow off so that the roof is not erloaded from a build up of water. Perimeter /edge walls or other roof extensions may block this discharge if overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in a = rdance with the Florida Building Code, Sections 4402, 4403 and 4413. 7. Ventilation: Most roof structures should have some ability to vent natural airflow through the or of the structural assembly (the building itself). The existing amount of attic ventilation shall not be reduced. It may be beneficial to consider additional venting which can result in extending the service life of the roof. x (-- m5D Owner's /Agent's Signature 4 / Date /0.2_61 0 /J , A/4- -- Property Address Permit Number • • Contractor's Signature 73ERM1T #: rkirl•NA I (01 Miami Shores Village APPROVED BY DATE ZONING DEPT Or WITH ALL N RULES AND REGULATIONS 642/0 FEDERAL BLDG DEPT SUBJECT CO CC.MPLIANCE STATE AND DCVN Florida Building Code Edition 2007 HIGH Velocity Hurricane Zone Uniform Permit Application Form Section A (General Information) Master permit No. Process No. Contractor's Name Quality Roofing Contractor, Inc. Job Address 10290 N.E. 2nd Avenue ❑ Low Slope ❑ Asphaltic Shingles ROOF CATEGORY ❑ Mechanically Fastened Tile❑ Mortar /Adhesive Set Tile ❑ Metal Panel/Shingles ❑ Wood Shingles/Shakes ❑ Prescriptive BUR -RAS 150 ROOF TYPE ❑ New Roof 0 Re- Roofing ❑ Recovering XIXRepair ❑ Maintenance ROOF SYSTEM INFORMATION Low Slope Roof Area (SF) Steep Sloped Roof Area (SF) Total (SF) N/A 1 /2sq. 1 /2sq. • • • • .... • .. .. • ... • . . • .. • • • • • • .... • .. • • • ▪ • • • :... • .. • • • • • • .. .. • • • • • . • • . . . • • • .. • •... • • .... Section B (Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. • MEM L Florida Building Code Edition 2007 HIGH Velocity Hurricane Zone Uniform Permit Application Form •••• Section D (Steep Sloped Roof System 1 • • • •••• • Exit.tinIg Ti *Roof • Roof System Manufacture Monier • Li f et i le LLC • • Product Approval number 0 7-1 0 2 3.12 • .. • • • • Minimum Design Wind Pressures, If Applicable (From RAS 127 or Calculations):' P1: -- P2: -- P3: -- •• • Maximum Design Pressure Product Approval Specific System -- Method of Tile Attachment: -- Deck Type: Type Underlaymen$ Insulation: Fire Barrier: Steep Sloped Roof System Description Wood Roof Slope 3 :12 I 301b. N/A 1 N/A Fastener Typo & Spacing: Adhesive Type: Type Cap Sheet Roof Covering: Ridge Ventilation? N/A Mean Roof Height 13 1 1/4" R/S nails Type 111 molting asphalt 901b. Flat White Tile Type & Size Drip Cap: 3 X 3 • • • • • •• • • • • • • • • • .• • • • • • • • •••• • • ••. • • • • •• • • MIAMDDADE BUILDING CODE COMPLIANCE OFFICE (BCCO) PRODUCT CONTROL DMSION NOTICE OF ACCEPTANCE (NOA) Monier Lifetile, LLC 200 Story Road Lake Wales, FL 33898 MIAMI -DADE COUNTY, FLORIDA METRO -DADE FLAGLER BUILDING 140 WEST FLAGJ.ER STREET gym 1603 Mall, IPRIDA•3.3n0 -1563 • • (305) 375;/92,1, FAX (805878 -2908 • • • • •••• • • •••• •• • • • • • • .• • • • • •• •• • • • SCOPE: • • • • • • • • This NOA is being issued under the applicable rules and regulations governing the use of construction:Infel lals. The documentation submitted has been reviewed by Miami -Dade County Product Control Division and •accepted • by the Board of Rules and Appeals (BORA) to be used in Miami Dade County and other areas where alewved by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right • to revoke this acceptance, if it is determined by Miami -Dade County Product Control Division that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Atlantis Shake & Slate Concrete Roof Tile LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This renews NOA #02- 1211.08 and consists of pages 1 through 7. The submitted documentation was reviewed by Alex Tigera. NOA No.: 07- 1023.12 Expiration Date: 12/16/12 Approval Date: 12/13/07 Page 1 of 7 • • • • • ROOFING ASSEMBLY APPROVAL Category: Sub - Category: Material: 1. SCOPE Roofing Flat Profile Roofing Tiles Concrete • • • • •• • • •••• • • •••• •. • • • • •••• •••• • • • .• • • • • . • • • • • .• • This renews a system using Monier Lifetile Atlantis Shake & Slate Contfete•Roof Tile, as manufactured Monier Lifetile LLC in Boca Raton, FL and described in Sectio 2bfihis NoticL of Acceptance. For locations where the pressure requirements, as determined by applicable B�rildi�g Code does not exceed the design pressure values obtained by calculations in ccnpp}ia;ice with MS 127 using the values listed in section 4 herein. The attachment calculations shall be dofie.0 Il moment based system. 2. PRODUCT DESCRIPTION Manufactured by, Applicant Dimensions Monier Lifetile 1 = 16" Atlantis Shake and w = 10" Slate Tile 1 'A" thick Trim Pieces 1= varies w = varies varying thickness 2.1 SUBMITTED EVIDENCE: Test Agency Redland Technologies The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. Test Specifications TAS 112 TAS 112 Test Identifier 7161 -03 Appendix III 94 -060A 94 -084 25- 7094 -2 25- 7094 -8 25- 7094 -5 Product Description Flat, interlocking, high pressure extruded concrete shake and slate roof tile equipped with two nail holes. For direct deck, mortar or adhesive set applications. Accessory trim, concrete roof pieces for use at hips, rakes, ridges and valley terminations. Manufactured for each tile profile. Test Name/Report Static Uplift Testing PA 102 & PA 102(A) Static Uplift Testing PA 101 (Mortar Set) (Adhesive Set) Static Uplift Testing PA 102 (4" Headlap, Nails, Direct Deck, New Construction) Static Uplift Testing PA 102 (4" Headlap, Nails, Battens) Static Uplift Testing PA 102 (4" Headlap, Nails, Direct Deck, Recover/Reroof) Date Dec. 1991 March, 1994 May 1994 Oct. 1994 Oct. 1994 Oct. 1994 NOA No.: 07- 1023.12 Expiration Date: 12/16/12 Approval Date: 12/13/07 Page 2 of 7 • • • ••..•• • • • • • • • • • • Test Agency The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. Redland Technologies Redland Technologies Redland Technologies Redland Technologies The Center for Applied Engineering, Inc. Professional Service Industries, Inc. Celotex Corporation Testing Service Walker Engineering, Inc. Walker Engineering, Inc. Walker Engineering, Inc. Walker Engineering, Inc. Walker Engineering, Inc. Walker Engineering, Inc. Walker Engineering, Inc. Walker Engineering, Inc. Nutting Engineerins Test Identifier 25- 7183 -6 25- 7183 -5 25- 7214 -1 25- 7214 -5 7161 -03 Appendix 11 Letter Dated Aug. 1, 1994 P0631 -01 P0402 Project No. 307025 Test #MDC -77 224 -47099 520109 -1 520111 -4 520191 -1 Calculations Calculations Calculations Calculations Calculations Calculations Calculations Calculations TAS -112 Test Name/Report Date •••• Static Uplift Testing • • • Feb ? 4995 PA 102 .. • (2 Quik -Drive Screws, Di? et ' Deck) .... • .• .• • • Static Uplift Testing • • • Febi 192 • PA 102 (2 Quik -Drive Screws, Ba ttsn Static Uplift Testing • PA 102 • 'so.' • • • March, 1995 (1 Quik -Drive Screw, Diy'ect.'. Deck) Static Uplift Testing PA 102 (1 Quik -Drive Screw, Battens) Wind Tunnel Testing PA 108 (Nail -On) Wind Tunnel Testing PA 108 (Nail -On) Wind Tunnel Testing PA 108 (Mortar Set) Withdrawal Resistance Testing of screw vs. smooth shank nails Wind Driven Rain PA 100 Physical Properties PA 112 Static Uplift Testing PA 101 .. • Aerodynamic Multiplier Moment of Gravity 25 -7094 25 -7496 25 -7584 25- 7804b -8 25- 7804 -4 & 5 25- 7848 -6 25 -7183 Aerodynamic Multipliers Two Patty Adhesive Set System 13343.1 • • .••. • • March, 1995 Dec. 1991 Aug. 1994 July 1994 Sept. 1993 Oct. 1994 Sept. 1994 Dec. 1998 March 1999 October 2007 August 2007 February 1996 April 1996 December 1996 March 1995 April 1999 April 1999 June 2007 NOA No.: 07- 1023.12 Expiration Date: 12/16/12 Approval Date: 12/13/07 Page 3 of 7 3. LIMITATIONS .... • • 3.1 Fire classification is not part of this acceptance. • •• • • • •. • • • • 3.2 For mortar or adhesive set tile applications, a static field uplift test shall:19e perforr d to • accordance with RAS 106. • 3.3 Applicant shall retain the services of a Miami -Dade County Certified LaUofatory to rerfor+n • quarterly test in accordance with TAS 112, appendix `A'. Such testing hirob.e subrpittect to • • the Building Code Compliance Office for review. • • 3.4 Minimum underlayment shall be in compliance with the applicable l;apfag Applica• tions .' • • • • Standards listed section 4.1 herein. • • 3.5 30/90 hot mopped underlayment applications may be installed perpendiaulartothe roof slope • • unless stated otherwise by the underlayment material manufacturers publitlied literates' • • • • • 3.6 This acceptance is for wood deck applications. Minimum deck requirements shalt be' in compliance with applicable building code. 3.7 May be installed on slopes 7:12 and greater with a minimum of two screws. 4. INSTALLATION 4.1 Monier Lifetile Atlantis Shake and Slate Concrete Roof Tile and its components shall be installed in strict compliance with Roofing Application Standard RAS 118, RAS 119, and RAS 120. 4.2 Data For Attachment Calculations Table 1: Average Weight (W) and Dimensions (I x w ) Tile Profile Weight -W (Ibf) Length -I (ft) Width -w (ft) Monier Lifetile Atlantis Shake & Slate Tile 8.5 1.33 0.833 Table 2: Aerodynamic Multipliers - A. ft3) Tile Profile X (ft3) Batten Application N/A A. (ft3) Direct Deck Application 0.208 Monier Lifetile Atlantis Shake & Slate Tile NOA No.: 07- 1023.12 Expiration Date: 12/16/12 Approval Date: 12/13/07 Page 4 of 7 Table 3: Restoring Moments due to Gravity - Ma (ft-ibf) Tile Profile 2 ":12" 3 ":12" 4 ":12" 5 ":12" 6 ":12" 7':12" or greater Monier Lifetile Atlantis Shake & Slate Tile Battens Direct Deck B jttens r Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck N/A 6.17 N/A 6.11 N/A 6.01 N/A 5.89 N/A 5.75 N/A 5.59 NOA No.: 07- 1023.12 Expiration Date: 12/16/12 Approval Date: 12/13/07 Page 4 of 7 Table 4: Attachment Resistance Expressed as a Moment - Mf (ft -Ibf) •••• for Nail -On Systems • •••• • Tile Profile Fastener Type Direct Deck (min 15!32" plywood) Direct Ded1 (min.19 /32' • plywoodn••• • Battdr4g•. • • • • • • • • Monier Lifetile Atlantis Shake & Slate Tile 2 -10d Ring Shank Nails 30.9 38.1 a, _. N/A 1 -10d Smooth or Screw Shank Nail 7.3 • 9.8 „•„• NIA• • - • . 2 -10d Smooth or Screw Shank Nails 14.0 18.8 : • : NIA . • • 1 #8 Screw 30.8 30.8 °„• ; N /4... 2 #8 Screw 51.7 51.7 11/1••• • 1 -10d Smooth or Screw Shank Nail (Field Clip) 24.3 24.3 N/A 1 -10d Smooth or Screw Shank Nail (Eave Clip) 19.0 19.0 N/A 2 -10d Smooth or Screw Shank Nails (Field Clip) 35.5 35.5 N/A 2 -10d Smooth or Screw Shank Nails (Eave Clip) 31.9 31.9 N/A Table 5: Attachment Resistance Expressed as a Moment Mf (ft-Ibf) for Two Patty Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Monier Lifetile Atlantis Shake & Slate Tile Adhesive' 31.32 1 See manufactures component approval for installation requirements. 2 Flexible Products Company TileBond Average weight per patty 13.9 grams. Polyfoam Product, Inc. Average weight per patty 8 grams. Table 5A: Attachment Resistance for Single Patty Expressed as a Moment - Mf (ft -Ibf) Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Monier Lifetile Atlantis Shake & Slate Tile PolyProT"" 118.9' PolyProT"" 40.44 3 Large paddy placement of 45 grams of PolyProT". 4 Medium paddy placement of 24 grams of PolyProTM. Table 5B: Attachment Resistance Expressed as a Moment - Mf (ft -Ibf) for Mortar or Adhesive Set Systems Tile Profile Tile Application Attachment Resistance Monier Lifetile Atlantis Shake & Slate Tile Mortar Sets 39.0 5 See specific mortar manufacturers Notice of Acceptance NOA No.: 07- 1023.12 Expiration Date: 12/16/12 Approval Date: 12/13/07 Page 5 of 7 5. LABELING .... All tiles shall bear the imprint or identifiable marking of the manufactu>1r'sjne orlege!or following statement: "Miami -Dade County Product Control Approved ". • • • . • .. • • •1 • • • • •1•. •• • • • • ▪ • • • • •••• • .. • • • • •• •• • • • • • • • • MONIER LIFETILE LLC, ATLANTIS SHAKE AND SLATE (BOCA RA:N, t+L PLA147).. LOCATED UNDERNEATH TILE • • 6. BUILDING PERMIT REQUIREMENTS 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance. 6.1.2 Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this system. NOA No.: 07- 1023.12 Expiration Date: 12/16/12 Approval Date: 12/13/07 Page 6 of 7 • • • • • PROFILE DRAWINGS ' .�.:... 112. WAtERLOUK �ti •� : \':.�• : a GVERLAY 0 .••. • • •••• • • • • •• • •••• • • • • • • • • • • • •••• •• • • • • • • • • • •••• • •• • • • • • • p,. •• •• • lI,r • • • • I. • • • • • • • • • • • • • • • • •• • •••• • • • • •••• MONIER LIFETILE ATLANTIS SHAKE & SLATE CONCRETE ROOF TILE END OF TIIIS ACCEPTANCE NOA No.: 07- 1023.12 Expiration Date: 12/16/12 Approval Date: 12/13/07 Page 7 of 7