BP-02-1860
Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Inspection Number: INSP- 161322 Permit Number: BP2002 -1860 Scheduled Inspection Date: June 24, 2011 Inspector: Bruhn, Norman Owner: JULMISSE, HARRY Job Address: 24 NW 109 Street Miami Shores, FL 33168 -4315 Project: <NONE> Contractor: THE HOME DEPOT AT HOME SERVICES Permit Type: Imported Permit Inspection Type: Final Work Classification: <NONE> Phone Number Parcel Number 1121360110190 Phone: 954- 979 -2137 Building Department Comments RE ROOF REMOVE EXIST TILES AND REPLACE W MONIER CAPRI NEVADA CLAY COLORTHRU Passed , ,i( Failed Correction Needed Re- Inspection Fee No Additional Inspections can be scheduled until re- inspection fee is paid. Inspector Comments June 24, 2011 For Inspections please call: (305)762 -4949 Page 18 of 18 A . Tomassi Roof Testing, Inc. 5451 NW 24th Street, Suite # 3 Margate, Florida 33063 TAS —106 Roof Tile Static Uplift Test Report Tel. 954 — 979 —1180 Fax. 954 — 979 —1182 Test Date: June 21, 2011 Project: 24 N.W. 109th Street, Miami, Florida Contractor: THD At Home Services Sub Contractor: Ram Construction Permit #: BP 2002 -1860 Roof Pitch: 3 / 12 Tile Installation Date: 2008 Attachment Method: Polyprofoam & Screw Tile Type: Monier All testing is in strict accordance with the 2007 Florida Building Code, High Velocity Hurricane Zone Testing Application Standard (TAS) 106 Each Test location was pulled using a Imada Force Gauge to a minimum of 35 lbs. TEST SUMMARY: Roof Area Total # of Tests # of Tests Passed % Passed Field 15 15 100% Corner 12 12 100% Perimeter 28 28 100% TEST RESULTS: PASSED See Attached Sketch For Further Details. Report Reviewed by: Dominick Scarfo, AR0010248 Dade Conn Certified Testin A ' enc # 07- 0720.04 Revises: # 03- 0317.03 Testing * Design Specifications * Management * Litigation * Quality Assurance 35' 10' 35' 25' T T T T T T T T T T T T T 25' T T T T T T T T T T T T 10' 2' 25' TAS —106 Test Locations All Dimensions are Approximate 40' T = Tested Tile and Passed F = Tested Tile and Failed B = Broken Tile M = Missing Tile N Project: w 24 N.W. 109th Street Miami, Florida • Certificate of Calibration ration # KELC- 122351 Kimball Electronic Laboratory, Inc. ision Monument Equipment Specialists KIMBALL ELECTRONIC LABORATORY, .INC 8081 W 21 LAME HIALEAH, FL 33016 Win: DIGITAL FORCE GAUGE Manufacturer IMADA Model Number DPSH-440 Part Nunes: DPSH-440 Range: 0-440 LBS Serial Number. 199171 Customer I.D.: N/A Gust. Bare de: N/A Cust Dept: N/A Specifications: +/- .2 LBS Purchase Order # A. TOMASSI ROOF TESTING, INC. 5451 NW 24 STREET #3 MARGATE FL 33063 Gal Date: 21-Apr-11 CaI. Due Date: 21- Jul -11 CaI. Interval: 3 MONTHS Received: IN TOLERANCE Calibration Result PASS Environmental Conditions: 72 DEG F / 38 % RH Performed By: JULIO GARCIA Procedure: SYN156 Cal Location: ON -SITE This is to certify that the above listed instrument meets or exceeds all specifications as stated in the referenced procedure at the points tested (unless othendse noted). It has been calibrated-using neasumnstnt stmudards traceable to the National Institute of Standards and Technology (NIST). or to NIST accepted intrinsic standards of measurement. or derived W the. ratio Woof of sets- calibration techniques. This calibration is in accordance with Kimball Electontc Laboratory. Inc Quality Assurance Manual. KELI's Quaky system is A21.A ` "to IS01iEC -1 and camPUWnt with MiL- STD45862A and ANSUNCSL Z540.3 -2006. TURS when applicable are great ttem or equal to 41: wah eked =Mainly usetto date the Test Uncertainty Ratio. with a coverage factor of K =2 at a confidence level of approximately 95 %. unless otherwise noted. Any number of factors may cause the calibration item to drift out of calibration before the recommended interval has expired. THIS UNIT VAS FOUND TO BE IN TOLERANCE AT THE TIME OF CALIBRATION. PE iFOMIED ROUTINE CAL. NO ADJUSTMENTS REQUIRED Company ID. iozio li r z. a Description KIM001 447 AKO TSD 2052-8B DEAD WEIGHT SYSTEM Codified by: JULIO GARCIA 21- Apr -11 Approved By: JAVIER 10:59:44 AM BALCEIRO 22- Apr-11 10:59:58 AM This report may not be reproduced, except in full, unless permission for the publication of an approved abstract is obtained in writing from KELI Labs., Inc. Kimball Electronic Laboratory, Inc. - 8081 W. 21st Lane - Hialeah, FL. 33016 Tel: 305 -822 -5792 - Toll Free: 800- 393 -1094 - Fax: 305 -362 -3125 - Web: www.kelilabs.com Last Cal. CaI. Due Date 05- Aug -10 31- Aug -11 i f , KELI Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 BUILDING PERMIT APPLICATION 1 BC 2004 7 JUN 3 2011 LJ Permit No. g(? $ Master Permit No. Permit Type (circle): Building Electrical Plumbing Mechanical Roof Owner's Name (Fee Simple Titleholder) tlieleb 3u Li^Y) I,SSrc. Phone # —35L1- C� Owner's Address locrty, ST City iYl1?*y1i Tenant/Lessee Name State C1 Zip 331 toZ *-f lq Phone # JOb Address (where the work is being done) (C)61+), Sr City Miami Shores Village County Miami -Dade FOLIO /PARCEL # 1 1 . i 3 G ®11 01 mot'® Is Building Historically Designated YES NO Zip 33 W3 Contractor's Company Name 1,14€1.1orne. Dom- AT— VtDry Sxs Phone # 1S* 336 ° COS 1 Contractor's Address fak, C44 rNI AefetAl..0 pj4 $ -nfro- % City ik'Culolici State Zip 3033 1 Qualifier Name Q b 1 J) KegerrS Phone # Cr514 — 53 (®`Og 8 State Certificate or Registration No. C Z .O5 - Certificate of Competency No. Architect/Engineer's N e (if applicable) �a Phone # Value of Work For this Permits' $ Square/Linear Footage Of Work: Type of Work: ['Addition ❑Alteration ['New ❑ Repair/Replace ❑ Demolition Describe Work: PEKrn t ; P1 1-�Ewy L 1 Cil LL F1) L 041 ft✓ c Q.t1 ****** * ** * ** *** * * * * * * * ** * ** * * * ** * * ** ** Fee ************* * * ** * * * * ** * ** * * * * * ** * * * * * * * ** ** Submittal Fee $ Permit Fee $ N $ 11 • Training/Education Fee $ $ t7 Radon $ DPBR $ CCF $ CO /CC Technology Fee $ Zoning $ Bond $ Code Enforcement $ Double Fee $ Structural Review. $ Total Fee Now Due $ See Reverse side — Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature Signature Per or Agent Contractor The foregoing instrument was acknowledged before me this 1 The foregoing instrument was acknowledged before me this ti day of �it , 20 i i , by }s i t 1_ S t6 day of e�� , 20h c, by L Q a 9 i 11 �r 4i— , who is personally own to me or who has produced Vim. . is person As identification and who did take an oath. NOTARY I? „90Q5`;;, ,q, MARIUSKA MORALES .0 MY COMMISSION # EE 079312 EXPIRES: April 11, 2015 4koFC a BondedThru Budget Notary+S8Ms>,s Sign: V� Sign: e or who has produced identification and who did take an oath. LIC: 4§+a,P:B4° MARIUSKA MORALES * MY COMMISSION # EE 079312 EXPIRES: April 11, 2015 43% M1 Q oo Banded Thru Budget Notary Services F Print: Print: • My Commission Expires: 0-11 _ — _c 4 My Commission Expires: to _ t I _ 7 r S APPLICATION APPROVED BY: (Revised 02/08/06) Plans Examiner Engineer Zoning Jun 27 11 07 :50a RAM Construction CO. 1 7 +NUJ "'1 fl JUN 2 r RED cvL RE: Perna # 32224 -/ 8G (Nit remand chola License Twej 5619639799 p.1 Miami Shores Village Building Depailment INSPECTION AFFIDAVIT license# Cc C "3 .. SS— 7 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 758.8972 DATE: 4/2.-1/% licensed as a (n) Contractor / Engineer /Architect, FS 468 Bu1ding Inspector On or about 6/z s z O % / ,1 dad personally infect the roof deck narng and @ate a tierce) Secondary water barrier worm at 2 / / w / ' y S -/r e .c • (Conrciloie Job site Address) Based upon that examination I have determined ihe installation was done according to the Hurricane Mtigation Retrofit Manual (Based on 553.844 F. S) Signature State of Florida County of Dade: The undersigned, Ming the first duty swam, deposes and says that heishe is the contractor for the above property merhioned. Sworn to and subscribed before me this 2-1 l4oiary Public, Sale of Florida al Large day of L4 /, - ZD // ROBERTO MARTIN MY COMMISSION # EE078000 EXPIRES March 27, 2015 `Geserat, % ,orRo Rooftop Coated= or an If loSidual ceza dvider46*FS.to make sash on impedes. Inhofe photographs of each plane dike root NIlt pane it and address it dfead', *min mafaedonOwdeckforeadi ios Revised on 5211103 Date Legal Description PERMIT APPLICATION FOR MIAMI SHORES VILLAGE 10050 N.E. 2nd Avenue • Mi4.n.i Scores, Florida 33138.305- 795 -2204 Job Address Owter/Lessee/Tenet Owner's Address Contracting Co. Tax Folio Historically Designated: Yes No Master Permit # ' r /'( ( Phone - 11 � Address _ Qualifier 1..-1 \ e -0 -- \ � i � ?� ' �= - SS# �- , , Phone � 1_ ( -, State # L , ' Municipal # Competency # ! (..' -'.--- ! `' Insi. Co. C''‘,d1 --ice 75-y- 5- sT-Fo �-. IF THERE IS NO PERMIT PACKAGE ACCESSIBLE ON THE JOB SITE FOR INSPECTORS TO VERIFY, THERE WILL BE NO INSPECTION. RE- INSPECTION FEE IS $50.00 AND MUST BE PAID IN ADVANCE 1 BEFORE CALLING FOR ANOTHER INSPECTION. (circle one): BUILDING ELECTRICAL PLUMBING MECHANICAL ROOFING WORK DESCRIPTION: �'� /`" . , y 1 �4i � '1 t �` ,_ Per;<nit Type � �' 4 1 °. „ , - _., -�; 1 _ �" oct,.°> el. Wil - Cil 0 B r c� Square Ft. 1 Estimated Cost (value) 1 ' -' -' WARNING TO OWNER: YOU MUST RECORD A NOTICE OF COMMENCEMENT AND YOUR FAILURE TO DO SO MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY (IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR ANY ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.) Application is hereby made to obtain a permit to do work and installation as indicated above, and on the attached addendum (if applicable). I certify that all Work will be performed to meet the (standards of all laws regulating construction in this jurisdiction. I understand that separate permits are required for'' all disciplines. OWNERS AFFIDAVIT: I certify that', all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Furthermore, I authorize the above named eontractor- todoo the-Work stated. / Signature of owner and/or Condo President Date • �..�.ignatur- of Contractor or Owner Builder I ALLARD 1 ,') - State of Flores 1,pires 7 5 21 Date'' i�d as to Contractor or On$i Builder My Commission Expires Notary as to Owner and/or Condo President ' 1%)y,' Commission Expires FEES: PERMIT 11 APPROVED: Zoning RADON Mechanical Date I ALLARD State of Flor?da (� r ; s.lua5,2C05 -DD039549Date C.C.F - NOTARY BOND _ TOTAL DUE Building» Plumbing Electrical Structural Engineer Florida Building Code Edition 2002 High Velocity Hurricane Zone Uniform Permit Application Form. 1 Section A (General Information) Master Permit No. Process No. Contractor's Name Job Address ❑ Low Slope ❑ Asphaltic Shingles ROOF CATEGORY ❑ Mechanically Fastened Tile ❑ Metal Panel /Shingles Mortar /Adhesive Set Tile ❑ Wood Shingles /Shakes ❑ Prescriptive BUR -RAS 150 ROOF TYPE ❑ New Roof ❑ Re- Roofing ❑ Recovering ❑ Repair ❑ Maintenance ROOF SYSTEM INFORMATION Low Slope Roof Area (SF) Steep Sloped Roof Area (SF) Total (SF) Section B (Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. MIAMI-T)ADE COUNTY, FLORIDA METRO -DADE FLAGLER BUILDING a PRODUCT COIfTROL NOTICE OF ACCEPTANCE BUILDING CODE COMPLIANCE OFFICE METRO -DADE FLAGLER BUILDING 140 WEST FLAGLER STREETT, SUITE 1603 MIAMI. FLORIDA 33130 -1563 (305) 375 -2901 FAX (305) 375 -2908 Monier Lifetile LLC 135 NW 20 St. Boca Raton FL 33431 CONTRACTOR LICENSING SECTION (305) 375 -2527 FAX (305) 375 -2558 CONTRACTOR ENFORCEMENTSECTION (305) 375 -2966 FAX (305) 375 -2908. PRODUCT CONTROL DIVISION Your application for Product Approval of: (305) 375 -2902 FAX (305) 372 -6339 Villa & Roll Capri Low Profile Tile under Chapter 8 of the Code of Miami -Dade County governing the use of Alternate Materials and Types o Construction, and completely described herein, has been recommended for acceptance by the Miami Dade County Building Code Compliance Office (BCCO) under the conditions specified herein. This approval shall not be valid after the expiration date stated below. BCCO reserves the right to secure th product or material at anytime from a jobsite or manufacturer's plant for quality control testing. If this product or material fails to perform in the approved manner, BCCO may revoke, modify, or suspend the use of such product or material immediately. BCCO reserves the right to revoke this approval, if it is determined BCCO that this product or material fails to meet the requirements of the South Florida Building Code. The expense of such testing will be incurred by the manufacturer. Acceptance No.:99- 1012.02 (Revises No.: 97- 1124.16) Expires: 12/16/2002 Chief Product Control Divisio THIS IS THE COVERSHEET, SEE ADDITIONAL PAGES FOR SPECIFIC AND GENERAL CONDITIONS BUILDING CODE & PRODUCT REVIEW COMMIi'1 LE This application for Product Approval has been reviewed by the BCCO and approved by the Building Code and Product Review Committee to be used in Dade County, Florida under the conditions set forth above. Approved:12/30 /1999 rancisco Quintana, R.A. Director 1 of 9 Miami -Dade County Building Code Compliance 0 :1 build ..,, ,.uullsHa� .• .Moat& MONTER LIFE TILE LLC _ ACCEPTANCE No.: 99- 4012.02 APPROVED :December 30, 1999 EXPIRES :December 16, 2002 NOTICE OF ACCEPTANCE: STANDARD CONDITIONS 1. SCOPE This revises a roofing system using Monier Lifetile Villa, Roll, and Capri Concrete Roof Tile, as manufactured Monier Lifetile LLC described in Section 2 of this Notice of Acceptance, designed to comply with the South Florida Building Code, 1994 Edition for Miami -Dade County. For the locations where the pressure requirements, as determined by SFBC Chapter 23, do not exceed the design pressure values obtain by calculations in compliance with RAS 127 using the values listed in section 4 herein. The attachment calculations shall be done as a moment based system. Category: - Prepared Roofing Sub Category: Low Profile Tile 2. PRODUCT DESCRIPTION Manufactured by Applicant Dimensions Monier Lifetile LLC Villa & Roll Monier Lifeitile LLC Capri Tile Trim Pieces 1= 16W w =13" V" thick L= 17" W =1234" %" thick' 1= varies w = varies varying thickness Test Specifications Product Description PA 112 Low profile, interlocking, high pressure extruded concrete roof tile equipped with one nail hole and double roll ribs. For direct deck or battened nail -on. mortar or adhesive set applications. PA 112 Low profile, interlocking, high pressure extruded concrete roof tile equipped with one nail hole and double roll ribs. For direct deck or battened nail -on, mortar or adhesive set applications. PA 112 Accessory trim, concrete roof pieces for use at hips, rakes, ridges and valley terminations. Manufactured for each tile profile. 2 F Zuloaga, RAC Roofing Product Control Examiner MONIER LIFETILE LLC NOTICE OF ACCEPTANCE: ACCEPTANCE No. 99- 1012.02— APPROVED :December 30, 1999 EXPIRES :December 16, 2002 STANDARD CONDITIONS 2.1 Components or products manufactured by others Product Rainproof II Ice and Water Shield Wood Battens Tile Nails Tile Screws Roof Tile Mortar ( "Ti leT iteTM") Roof Tile Mortar ( "Quikrete® Roof Tile Mortar #1140 ") Dimensions 30 "x75' roll 36"x75'roll or 60" x 75' roll 36 "x75' roll Vertical Min. 1 "x 4" Horizontal Min. 1 "x 4" for use with vertical battens or Min. 1 "x 2" for use alone Min. 10dx 3" #8x 2 %" long 0.335" head dia. 0.131" shank dia. 0.175" screw thread dia. N/A N/A Test Specifications Product Description Manufacturer PA 104 Single ply, nail -on Protect O -Wrap, underlayment with Inc. 2" self-adhering top (with current NOA) edge. PA 103 Self - adhering W.R. Grace Co. underlayment (with current NOA) Wood Preservers Salt pressure Institute LP — 2 treated or decay resistant lumber battens PA 114 Appendix E PA 114 Appendix E PA 123 PA 123 Corrosion resistant screw or smooth shank nails Corrosion resistant, coated, square drive, galvanized, coarse thread wood screws Prepared mortar mix designed for mortar set roof tile applications. Prepared mortar mix designed for mortar set roof tile applications. generic generic generic Bermuda Roof Company, Inc. with current PCA Quikrete Construction Products with Current PCA Zuloaga, RRC Roofing Product Control Examiner iti1ONIER LIFETILE LLC ACCEPTANCE No.: 99- 1012.02 APPROVED :December 30, 1999 EXPIRES :December 16, 2002 NOTICE OF ACCEPTANCE: STANDARD CONDITIONS Test Product Product Dimensions Specifications Description Manufacturer Roof Tile Mortar N/A PA 123 Prepared mortar W. R. Bonsai Co. ( "BONSAL® mix designed for with current PCA Roof Tile Mortar mortar set roof tile Mix ") applications. Roof Tile Adhesive ("Polypro® AH 160 ") Roof Tile A3Ties e^ TileBond NIA Factory premixed canisters See PCA Two component Polyfoam Products, polyurethane Inc. adhesive designed for adhesive set roof tile applications. See PCA Single component Flexible Products polyurethane (with current foam roof tile NOA) adhesive Hurricane Clip & , Clips PA 114 Appendix E Corrosion resistant Fasteners Min. %a" width clips with corrosion Min. 0.060" thick resistant nails. Clip Fasteners Min. 8d x 1'/." 3. LIMITATIONS Generic 3.1 Fire classification is not part of this acceptance. 3.2 For mortar or adhesive set tile applications, a static Feld uplift test shall be performed in accordance with RAS 106. 3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test in accordance with PA 112, appendix 'A'. Such testing shall be submitted to the Building Code Compliance Office for review. 3.4 Minimum underlayments shall be in compliance with the applicable Roofing Applications Standards listed section 4.1 herein. 3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature. 3.6 This acceptance is for wood deck applications. shall. ° be in compliance with chapter 29 of the SFBC. tnk uloaga. RRC Roofing Product Control Examiner ivtiatri.t.,K Lit' t: 1 (Lt, LLC. ACCEPTANCE Yo.: 99- 1012.02 APPROVED :December 30, 1999 EXPIRES :December 16, 2002 NOTICE OF ACCEPTANCE: STANDARD CONDITIONS 4. INSTALLATION 4.1 Monier Lifetile Villa, Roll, and Capri Concrete Roof Tile and its components shall be installed in strict compliance with Miami Dade County Roofing Application Standard RAS 118, RAS 119, and RAS 120. 4.2 Data For Attachment Calculations Table 1: Aerodynamic Multipliers - X (ft') Tile Profile 1. (ft') Batten Application A. (f e) Direct Deck Application Monier Ufetile Villa, Roll and Capri Tile 0.267 0.289 Table 2: Restoring Moments due to Gravity - M. (ft-lbf) Tile . Profile 3 ":12" 4 ":12" 5 ":12" 6°°:12" 7":12" or greater Monier Lifetile Villa, Roll, and Capri Tile Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck 5.57 6.30 5.48 6.18 5.37 6.05 524 5.90 5.09 5.73 Table 3: Attachment Resistance Expressed as a Moment - M, (ft -Ibf) for Nail -On Systems Tile Fastener Type Direct Deck Direct Deck Profile (min 15/32" (min. 19132" plywood) plywood) Battens Monier Lifetile Villa, Roll, and Capri Tile 2 -10d Ring Shank Nails 1 -10d Smooth or Screw Shank Nail 27.8 37.4 28.8 8.8 11. 4.1 2 -10d Smooth or Screw Shank Nails 16.4 21.9 7.1 1 #8 Screw 25.8 25.8 22.9 2 #8 Screw 47.1 47.1 49.1 1 -10d Smooth or Screw Shank Nail (Field Clip) 1 -10d Smooth or Screw Shank Nail (Eave Clip) 24.3 24.3 24.2 19.0 19.0 22.1 2 -10d Smooth or Screw Shank Nails (Field Clip) 35.5 35.5 34.8 2 -10d Smooth or Screw Shank Nails (Eave Clip) 31.9 31.9 32.2 2 -10d Rin Shank Nails' 43.0 Installation with a 4" 'le headlap and fastemers are located a min. of 2° Frank Zuloaga, RRC Roofing Product Control Examiner Q MONIER LIFETILE LLC ACCEPT.A.NCE No.: 994012.02 APPROVED :December 30, 1999 EXPIRES :December 16, 2002 NOTICE OF ACCEPTANCE: STANDARD CONDITIONS Table 4: Attachment Resistance Expressed as a Moment Mi (ft Ibf) for Two Patty Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Monier Lifetile Villa, Roll, and - Capri Tile Adhesive 26.13 2 See manufactures component approval for installation requirements. 3 Flexible Products Company TileBond Average weight per patty 11.4 grams. Poi oam Product, Inc. Average wei *ht per pa 8 .rams. Table 4A: Attachment Resistance Expressed as a Moment - Mr (ft Ibf) for Single Patty Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Monier Lifetile Villa, Roll, and Capri Tile Polyfoam PolyProTli 86.614 Polyfoam PolyProT"" 45.55 4 Large paddy placement of 54grams of PolyProp". 5 Medium paddy placement of 24�rams of PolyPro114. Table 4B: Attachment Resistance Expressed as a Moment - Mt (ft-lbf) for Mortar Set Systems Tile Profile Monier Lifetile Villa, Roll, and Capri Tile Tile Application Mortar Set' Attachment Resistance 20.60 5. LABELING All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo, or foIlowingjtatement: "Miami -Dade County Product Control Approved ". 6. BUILDING PERMIT REQUIREMENTS 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance. . 6.1.2 Any other documents required by the Building Official or the South Florida Building Code (SFBC) in order to properly evaluate the installation of this system. uloaga. RRC Roofing Product Control Examiner < MONIER LIFETILE LLC ACCEPTANCE.N.p. : 99-1012.02 APPROVED :December 30, 1999 EXPIRES :December 16, 2002 NOTICE OF ACCEPTANCE: STANDARD CONDITIONS PROFILE DRAWINGS NA& HUE Villa MONIER LIFETILE VILLA CONCRETE ROOF TILE MONIER LIFETILE ROLL CONCRETE ROOF TILE Frank Zuktaga, RRC hoofing Product Control Examiner MONIER LIFETILE LLC ACCEPTANCE No. : 99-1012.02 APPROVED :December 30, 1999 EXPIRES :December 16, 2002 NOTICE OF ACCEPTANCE: STANDARD CONDITIONS MONIER LIFETILE CAPRI CONCRETE ROOF TILE ACCEPTANCE No.: 99 -0,17.e2 APPROVED :December 30, /999 EXPIRES :December 16, 2002 I.N i . Renewal of this Acceptance (approval) shall be considered after a renewal applicatlon has been filed and the original submitted documents, including test-supporting data, engineering documents, are no alder than eight (S) years. 2. Any and all approved products shall be permanently labeled with the manufacturer's name, city, state, and the following; statement: Miami Dade County Product Control Approval ", or as specifically stated in the specific conditions of this Acceptance. Renewals of Acceptance will not be considered if a. There has been a change in the South Florida Building Cade affecting the evaluation of this - product and the product is not in compliance with the ode changes. b. I f product is nce holderr has nnotcompl (identical) as the one all the requirements of this acceptance, c. If the Acceptance including the correct installation of the product. uiradocumentation 'initially 'initially d. The engineer who originally prepared, signed and sealed the documentation submitted, is no longer practicing the engineering profusion. 4. Any revision or change in the materials, use, and/or manufacture of the product or process shall automatically be rise for termination of this Ate, unless prior written approval has been requested (through. the filing of a revision application with appropriate fee) and granted by this office. 5. Any of the following shall also be grounds for removal of this Acceptance: a, Unsatisfactory performance of this product or process• advertising or any b. Misuse of this Acceptance as an endorsement of any product, far sales, advertising other purposes. ce number receded by the words I� iamE -lade County, Florida,. and 6. The Notice of Acceptance P followed expiration by the expration date may be displayed in advertising literature. if any portion of the Notice of Acceptance is displayed, then it' shalt be done in its entirety. 7. A copy of this Acceptance as well as approved drawings and other documents, where it applies, shall be prUvided to the use' by the manufacturer or its distributors and shall be available for inspection at the job site at all time. The engineer need -not reseal the copies. 8. Failure to comply with any section of this Acceptance shall be cause for termination and removal of Acceptance_ 9. This Notice of Acceptance consists of pages 1 through 8 and this last page 9. END OF THIS ACCEPTAN 9 — Ztrleaga. RAC Roofing ProdUr t Control Examiner Florida Building Code Edition 2002 High Velocity Hurricane Zone Uniform Permit Application Form. Section A (General Information) Master Permit No. Process No. Contractor's Name Job Address - Y= ❑ Low Slope ❑ Asphaltic Shingles 4 i ROOF CATEGORY ❑ Mechanically Fastened Tile J Mortar /Adhesive Set Tile ❑ Metal Panel /Shingles ❑ Wood Shingles/Shakes ❑ Prescriptive BUR -RAS 150 ROOF TYPE ❑ New Roof 0 Re- Roofing ❑ Recovering ❑ Repair 0 Maintenance ROOF SYSTEM INFORMATION Low Slope Roof Area (SF) Steep Sloped Roof Area (SF) Total (SF) Section B (Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. Florida Building Code Edition 2002 High Velocity Hurricane Zone Uniform Permit Application Form. Section D (Steep Sloped Roof System) IMP Roof System Manufacturer: MOME.I. Li FE 711_E Notice of Acceptance Number: 1 — ) 01.. Oa Minimum Design Wind Pressures, If Applicable (From RAS 127 or Calculations): Pmaxl: �i-�. (n Pmax2: —100' Pmax3: — 100. (p { MaximufrDesignl. Pressure (From the NOA Specific System): Method of tile attachment F-0 14-M eoL/ PRo • Steep Sloped Roof System Description Deck Type: .n Type Underlayment: Insulation: 3o F-s-rM N(k. Fire Barrier. , ` Ridge Ventilation? 1\1 / Fastener Type & Spacing 1 h1't" RS (011:..j' Adhesive Typ }s-r ype Cap Sheet I � �l Mean Roof Height: ! -TN PE y- - I=o Prs-rrH Roof Covering: C PR i Co O* TE. fooF -TILE. Type & Size Drip Edge: 6 vtim Et .3X_3 Florida Building Cod• Edition 2002 H• h Valid Hurricane Zone Uni o m Ptnrrttt licatiori Form. Section J (Tile Calculations) For Moment based tile systems, choose either Method I or 2. Compared the values for M, with the values from Mr If the Mr values are greater than or equal to the Mr values, for each area aide roof, then the tile attachment method is acceptable. "y7�(�1 M Method 1 "Mome t Based Tile Calcutati pps Per RAS 127" (Pt: � = e - M$:. (o• 3� M,t 17- IV NOA M cP :: -loo. : a . a ys - Mg: 6.30= M, a. (P3: -100. r X 4, :' ' , — Mg: X30 . K, te NOA M Method 2 "Simplified Tile Calculation Per Table Below" Required Moment of Resistance (M,) From Table Below _ NOA Mt M, Required Moment Resistance' ges *Must be used in conjunction with a list of moment based tile systems endorsed by the Browsrd County Board of Ryles and Appeals. For Uplift based tile systems use Method 3. Compared the values for F' with the values far F,. If the F' values are greater than or equal to the Fr values, for each area of the roof, then the We attachment method Is acceptable. Method (Pi : ,4Y : is ,. (P2: s 1: -� (Pa • :1 ::t 3 "Uplift Based i "w: " _j - W: Tile Calculations Per RAS 127" .�_ z cos Y cos B.• = F1: x cos e: - Fes: NOAF' NOA Now F Descri . tion Where to find RAS 107 Table 1 or by an engineering analysis prepared by PE based on ASCE 7 Calculated - Tile Dimensions !® length F►OA All calculations must width be submitted to the 8uddin OMTietal u the tune of SECTION 1524 HIGH VELOCITY HURRICANE ZONES - REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS §1524.1 Scope. As it pertains to this section, it is the responsibility of the roofing contractor to provide the owner with the required roofing permit, and to explain to the owner the content of this section. The provisions of Chapter 15 of the Florida Building Code, Building govem the minimum requirements and standards of the industry for roofing system installations. Additionally, the following items should be addressed as part of the agreement between the owner and the contractor. The / 4 owners initial is the designated space indicates that the item has been explained. 1. Aesthetics- Workmanship: The workmanship provisions of Chapter 15 (High Velocity Hurricane Zone) are for the purpose of providing that the roofing system meets the wind resistance and water intrusion performance standards. Aesthetics (appearance) are not a consideration with respect to workmanship provisions. Aesthetic issues such as color or architectural appearance, that are not part of a zoning code, should be addressed as part of the agreement between the owner and the contractor. 2. Renailing Wood Decks: When replacing roofing, the existing wood roof deck may have to be renailed in accordance with the current provisions of Chapter 16 (High Velocity Hurricane Zones) of the. (The roof deck is usually concealed prior to removing the existing roof system). 3. Common Roofs: Common roofs are those which have no visible delineation between neighboring units (i.e., townhouses, condominiums, etc.). In buildings with common roofs, the roofing contractor and/or owner should notify the occupants of adjacent units of roofing work to be performed. 4. Exposed ceilings: Exposed, open beam ceilings are where the underside of the roof decking can be viewed from below. The owner may wish to maintain the architectural appearance; therefore, roofing nail penetrations of the underside of the decking may not be acceptable. The provides the option of maintaining this appearance. 5. Ponding Water. The current roof system and/or deck of the building may not drain well and may cause water to pond (accumulate) in low -lying areas of the roof. Ponding can be an indication of structural distress and may require the review of a professional structural engineer. Ponding may shorten the life expectancy and performance of the new roofing system. Ponding conditions may not be evident until the original roofing system is removed. Ponding conditions should be corrected. 6 Overflow Scuppers (wall outlets): It is required that rainwater flow off so that the roof is not overloaded from a buildup of water. Perimeter /edge walls or other roof extensions may block this discharge if overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in accordance with the requirements of: 7. Ventilation: Most roof structures should have some ability to vent natural airflow through the interior of the structural assembly (the building itself). The existing amount of attic ventilation shall not be reduced. It may be beneficial to consider additional venting which can result in extending the service life of the roof. 7 -`' (Ow er's/Age is Signature Date Cont •actor's Sig yture t M14 MIAMI-DADE METRO-DADE FLA RIDA ING •P 2 srt,- 1 7 - Yur OL NOTICE Products, Inc. tuebner Road 77383-1132 1 lt CE ANC BUIRARDiO CODE COMFLIA METRO-DADE 140 WM-FLAMER MIAML (315)375-NDI FAX curtntacTOR 373-25Z7 E cxemeAcronanzonCw■ noslriseses,Vo. PRODUCT lion for Notice of Acceptance (NOA) of mponent Polymath.= Foam Adhesive 8 of the Code of beami-Dade County governing the use of Alternate Materials mid eompletdy des:rand harem' , has been recommended for acceptance by the Code Compliance Office (BCCO) under the conditions specified hendn. A shalt not be 'valid' after the expiration date stated below_ BCCO reserves the right or material at any time from a jobeke or manufacturer's plant for quality control or material iIS to perform in the approved manner. BCCO may reinsice, morlify, product or material knmetrtately. BCC° reserves the right to revoke this ned by DCCO that this product or material Mb to to the requiremcnts of the Code. ORR 371120iR of such testing will be incurred by the numufaaturer. ANCENfax 01-1*2142 EXPIRES: KAMM rall if it Raul Rodriguez Chief Product C •■ • IS S E 117 • A FC FOR 1ON1rnQNS ILUR'fG tgPtOt/mtlml COMMfl reunion fin- Product Approval line been ret;iewed by the BCCO and approved Product Review Committee to be used in Miami-Dade County, Florida under the OVED: 06/14/2M1 Francisco 1. Qui Director Count Buikrutg C.nde on' !line Iipasffillampbteanoneaanaptancearier pazedet t muil addresk pastranstengIndltroccadennline.coni • HoulePaR= IIuPlAvww-hundingendean nt G ASSEMBLY APPROVAL Roofing RoofTile Adhesive COPE is approves PoIypro® A11160 as manufactuted by Potyiaam Products, Inc as 'bed hi Section 2 of this Notice of Acceptance. Por the locations when the design x tequicemtu. Os detezmined by applicable hullding code. does not exceed the gn pressure values obtained by calculations in compliance with Roofing A . k. s • RAS 127, for use with approved flat, low, and high profile roof tiles system olypactD AN 160.. Where the attachment calculations are done as a based r single ley Pine and as an uplift based system for double pauy systems Polyurethane ACCEPTANCE No. _ 01- 9521.. APProv d Date: atem14. 2gQi Expiration Dal= May 1 , 2006 RODUCT DESCRIPTION Eby oat AHIId RTFtt 30 8t 100 1liulaes N/A NIA Test PA 101 Product lion Two component polyurethane DisIntesing Equipment N/A i Equipment 2.1 Components or putts manufactured by others: Any Assembly a current which list �� values with the ypro A11160 roof u"%e adhesive. 2.2 Typical Physical Propertialc Pr_ a_isrix Test y ASTM D 16. 2 Compressive AS t Art D 1621 Strength Tensile Strength ASTM D 1623 Water Absorption ASTM 0 2127 Moisture Vapor ASTM E 96 Transmission Dimensional ASTM D 2126 Stability 1.6 Iln./I1_3 18 PSI i'amilel to rise 12 PSI Perpendicular to rise 28 PSI Parallel to rise 0.08 LbsJFt2 3.1 Perm l Inch Volume Change a -400 F 2 weeks t1% Volume Q*an*c sib I Tumidity, 2 weeks Frank Zu[oaga.. RRC Product Control Examiner rut. ACCEPTANCt N. : 01-052/. i 1 4.8 Tiles mist be adhered 'in ireshly applied adhesive. 'Tile must be set within 2 to 3 - minutes after Polyprof10 AHI60 has been dispensed_ 4-9 Polypi AHI60 placement and minimum patty weight shall be le accordance wit the Placement Details* beveia Each genetic Inc profile requires the specific p1acen4Int noted herein. Table 1: Adhesive Placement Far Each Generic Tat Profile THerrefile Placement Sbsgle Paddy Weight Two Paddy Weight Detail Wm. (grams) per paddy Min. Low Profiles II 1 35 NIA gh Profile (2 Picea Ram* #1 Made en cap and NIA 34ipan 24 W4 Low- 1-figh Profiles Low,„ Ih* Profiles. ELING AB Polyp AH160 containesindi comply with the Standard Cosufuicas listed WILDING maw REQUIREMENTS 6-1. As required by the Buifdfng Official or applicable Building Code in order to properly evaluate the installation of this system. 4 Frank Zulu:ago RRC Product Control Examiner t loam Propels. ACCEPTANCE No. : 01-4L 1.02, ADHESIVE PLACEMENT DETAIL 3 DOUBLE PATTY Pa* tbasesener4 FaNI (uaderge) kiTitmefogs saspithveave ixossody AMMIMIMI■ Frank Zukrasm, RAC Punka antral Examiner 7 ' °I! ° rod ici Inc, ACCEPTANCE No.: O 1 1. 3.. Repewal of this Acceptance ( shall be considered alto- a renewal applies has been and the original submitted documents. including older than eight (8} yam. tcst-supporting data. ensinecnins documents. Any and all approval products shall and the � d utid& the �e�s specifically s in the Pn 1 Appip lam. o Acceptance- Renewals of-Acceptance will not be consideted if There has been a change in the South Florida product and the product is not in • The product � affecting wifi c. If the Acceptance her � (�9 as t� o� y aPFlaved- d. �d� with tt!l the of this _arigin: ft FinFarad• signed d. and r + r�tason "" is ao l practicing the Any rewisiwt or change in � - antonatically 6e �. tbs�"s andlor faetrue of the � process requested Acceptmee. unless prim written aiffce.(through the filing of a revision applicathm with appropriate fee) and marital by *fare also he g n� of this A c: b. Misuse Orp other purpose& �asan endorsement of any for sales. for Nofinc . ,. �, by the D County. Florida. and ..; . tha If any portion of the S don it std be done ;a entirety. copy of this Acceptance as well as appnwed draw' user � R applics, �to the bthe ' or its and shall ��tar �a all time. The engineer aced not reseal Lo comply wihanpsectionof t A shall be cause for tennination and IMO; Notice ofAplance combo of pages 1 8_ END OF T105 ACCEPTANCE 8 Froth= Examiner I High Florida Building Code Edition 2002 itobrcay Hurricane Zane WA= Faro Apaca ladFonn. Section E ITile Calculations) For Moment based tile systems. goose either Method 1 or 2. Compared the vain for Mrwith the values from MF lithe Mr values are greater than or equal to the M values, for each area of the roof; then the tile attachment method is acceptable. Method 1 "Mo ent Based 1 ile Calculations Per RAS 127" (P,: •6 :1 0-AY' - J. -erg: o = M,, 5 ?a Now bit `fo. t'100. .� a . )- =M.: adv. NOA yQ_ Method 2 "Simplified Tie Calculation Per Table Below" { Required Moment of aesigance (Mr) From Table Below NOA tMr { Man Roof Roe --1► 2212 4.-12 &-12 111, Required M 15' 34.4 32.2 30.4 23.4 25.4 244 35.5 3L4 32.2 30.1 29.0 25' 35.2 35.0 33.5 314 211.4 27.1 30' 39-7 37.4 35.1 32.5 304 *Must be used in etudonction with a list of moment based to systems endorsed by Broward County Board of Rules and Appeals. For Uplift based to systems use Method 3. Compared the values for F' with values for F,. If the F' values are greater than or equal to the Fr values, for ea area of the roof, then the tile attachment method is acceptable. (p• • x b Method 3 "Uplft Based Tile Minns Per RAS 127" = w: ) —W: :oesdt = F (Ps: x l: x w: =�)— W: NOAF (Pa: :l: I erns � F . NOA F 1: x w: ) — W: I cos & = Fro: NOA F # Where to Obtain Information Description Symbol Where to find DnPie P1arP2orP3 RAS 127 Table 1arbyao anabsis prepared by 7 Mean Racil'ilsigbt, H meow ]l alloma due tlattianra► NL lob Site lob Site NOA NOA Mildaserit ear NOA Reignited Moms* ResbEence Ns Catodared Waimea Andes= Bedroom r NO* ,---____ftsW5 Utak Resissmas F Cale Avaap tag Wien IV NO4 Tde Efimassions N toga NO* or. width A0 au to the 8=. _T Owl a the rase ammo zoPtecalion MIA MIAMI -DADE COUiriTY. FLORIDA METRO -DADE FLAGLER BUILDING PRODUCT COi'TROL NOTICE OF ACCEPTANCE BUILDING CODE COMPLIANCE OFFICE METRO -DADE FLAGLER BUILDING 140 WEST FLAGLER STREET SUITE 1603 MIAMI. FLORIDA 33130 -1563 (305) 375 -2901 FAX (305) 375 -2908 Monier Lifetile LLC 135 NW 20 St. Boca Raton CONTRACTOR LICENSING SECTION (305) 375 -2527 FAX (305) 375 -2558, FL 33431 CONTRACTOR ENFORCEMENT SECTION (305) 375 -2966 FAX (305) 375 -2908. PRODUCT CONTROL DIVISION Your application for Product Approval of: (305) 375 -2902 FAX (305)372 -6339 Villa & Roll Capri Low Profile Tile under Chapter 8 of the Code of Miami -Dade County governing the use of Alternate Materials and Types o Construction, and completely described herein, has been recommended for acceptance by the Miami -Dade County Building Code Compliance Office (BCCO) under the conditions specified herein. This approval shall not be valid after the expiration date stated below. BCCO reserves the right to secure th product or material at anytime from a jobsite or manufacturer's plant for quality control testing. If this product or material fails to perform in the approved manner, BCCO may revoke, modify, or suspend the use of such. product or material immediately. BCCO reserves the right to revoke this approval, if it is determined BCCO that this product or material fails to meet the requirements of the South Florida Building Code. The expense of such testing will be incurred by the manufacturer. Acceptance No.:99- 1012.02 (Revises No.: 97- 1124.16) Expires:12/16/2002 Raul Rodriguez Chief Product Control Divisio THIS IS THE COVERSHEET, SEE ADDITIONAL PAGES FOR SPECIFIC AND GENERAL CONDITIONS BUILDING CODE & PRODUCT REVIEW COMMITTEE This application for Product Approval has been reviewed by the BCCO and approved by the Building Cod ■ and Product Review Committee to be used in Dade County, Florida under the conditions set forth above. Approved:12/30 /1999 -r® build 1 of9 t =..eKguge: rancisco Quintana, R.A. Director Miami -Dade County Building Code Compliance 0 9.��ilusn�t. ••. �u� itiMONIER LLFETILE LLC _ ACCEPTANCE Ifo.: 99- 1012.02 APPROVED :December 30, 1999 EXPIRES :December 16, 2002 NOTICE OF ACCEPTANCE: STANDARD CONDITIONS 1. SCOPE This revises a roofing system using Monier Lifetile Villa, Roll, and Capri Concrete Roof Tile, as manufactured Monier Lifetile LLC described in Section 2 of this Notice of Acceptance, designed to comply with the South Florida Building Code, 1994 Edition for Miami -Dade County. For the Iocations where the pressure requirements, as determined by SFBC Chapter 23, do not exceed the design pressure values obtain by calculations in compliance with RAS 127 using the values listed in section 4 herein. The attachment calculations shall be done as a moment based system. Category Prepared Roofing Sub Category: Low Profile Tile 2. PRODUCT DESCRIPTION Manufactured by Test Product Applicant Dimensions Specifications Description Monier Lit:gag .LW L = 161/2" Villa & Roll w = 13" %" thick Monier Lifeitile LLC Capri Tile Trim Pieces L = 17" W= 12 ' /," ''/2" thick ' 1= varies w = varies varying thickness 0 PA 112 Low profile, interlocking, high pressure extruded concrete roof tile equipped with one nail hole and double roll ribs. For direct deck or battened nail -on, mortar or adhesive set applications. PA 112 Low profile, interlocking, high pressure extruded concrete roof tile equipped with one nail hole and double roll ribs. For direct deck or battened nail -on, mortar or adhesive set applications. PA 112 Accessory trim, concrete roof pieces for use at hips, rakes, ridges and valley terminations. Manufactured for each tile profile. 2 Frank Zuloaga, RRC Roofing Product Control Examiner M©NIER LIFETILE LLC NOTICE OF ACCEPTANCE: ACCEPTANCE No.: 99- 1012.a2— APPROVED :December 30, 1999 EXPIRES :December 16, 2002 STANDARD CONDITIONS 2.1 Components or products manufactured by others Product Rainproof 1I Ice and Water Shield Wood Battens Tile Nails Tile Screws Roof Tile Mortar ( "TileTiteTM") Roof Tile Mortar ( "Quikrete® Roof Tile Mortar # 1140") Dimensions 30" x 75' roll 36" x 75' roll or 60"x75'roll 36" x 75' roll Vertical Min. 1 "x 4" Horizontal Min. 1 "x 4" for use with vertical battens or Min. I "x 2" for use alone Min. 10dx 3" #8x 2 Ys" long 0335" head dig 0.131" shank dia. 0.175" screw thread dia. N/A N/A Test Specifications PA 104 PA 103 Wood Preservers Institute LP — 2 PA 114 Appendix E PA 114 Appendix E PA 123 PA 123 Product Description Single ply, nail -on underlayment with 2" self - adhering top edge. Self - adhering underlayment Salt pressure treated or decay resistant lumber battens Corrosion resistant screw or smooth shank nails Corrosion resistant, coated, square drive, galvanized, coarse thread wood screws Prepared mortar mix designed for mortar set roof tile applications. Prepared mortar mix designed for mortar set roof tile applications. Manufacturer Protect -O -Wrap, Inc. (with current NOA) W.R. Grace Co. (with current NOA) generic generic generic Bermuda Roof Company, Inc. with current PCA Quikrete Construction Products with Current PCA Zuioaga, RRC Roofing Product Control Examiner MONIER LIFETILE LLC Product ACCEPTANCE No.: 99- 1012.02 APPROVED :December 30, 1999 EXPIRES :December 16, 2002 NOTICE OF ACCEPTANCE: STANDARD CONDITIONS Roof Tile Mortar ( "BONSAL® Roof Tile Mortar Mix ") Roof Tile Adhesive ("Polypro® AI-1160") Roof Tile A e Ti el Bond Dimensions N/A N/A Factory premixed canisters Hurricane Clip & Clips Fasteners Min. 1a" width Min_ 0.060" thick Clip Fasteners Min. 8d x 1 %" 3. LIMITATIONS Test Specifications PA 123 Prod uct Description Prepared mortar mix designed for mortar set roof tile applications. Manufacturer W. R. Bonsai Co. with current ?CA See PCA Two component Polyfoam Products, polyurethane Inc. adhesive designed for adhesive set =idle applications. See PCA Single component polyurethane foam roof tile adhesive PA 114 Appendix E Corrosion resistant clips with corrosion resistant nails. Flexible Products (with current NOA) Generic 3.1 Fire classification is not part of this acceptance. 3.2 For mortar or adhesive set tile applications, a static field uplift test shall be perkormed in accordance with RAS 106. 3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test in accordance with PA 112, appendix `A'. Such testing shall be submitted to the Building Code Compliance Office for review. 3.4 Minimum underlayments shall be in compliance with the applicable Roofing Applications Standards listed section 4.1 herein. 3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature. 3.6 This acceptance is for wood deck applications. be in compliance with chapter 29 of the SFBC. uloaga, RRC Roofing Product Control Examiner trukivite.ti. t I LLI LI_A- ACCEPTANCE : 99-1012.02 APPROVED :December 30, 1999 EXPIRES :December 16, 2002 NOTICE OF ACCEPTANCE: STANDARD CONDITION'S 4. INSTALLATION 4.1 Monier Lifetile Villa, Roll, and Capri Concrete Roof Tile and its components shall be installed in strict compliance with Miami Dade County Roofing Application Standard RAS 118, RAS 119, and RAS 120. 4.2 Data For Attachment Calculations Table 1: Aerodynamic Multipliers - X (f3) Tile X (fe) 2. (ft) Profile Batten Application Direct Deck Application Monier Lifetile Villa, Roll and Capri Tile 0.267 0.289 Table 2: Restoring Moments due to Gravity - Mg (ft-lbf) Tile • Profile 3":12" 4":12" 5":12" 6":12" 7":12" or greater Monier Ufetile Villa, Roll, and Capri Tile Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck 5.57 6.30 5.48 6.18 5.37 6.05 . 5.24 5.90 5.09 5.73 Table 3: Attachment Resistance Expressed as a Moment - MI (ft-Ibf) for Nail-On Systems Tile Fastener Type Direct Deck Direct Deck Profile (min 15/32" (min. 19/32" plywood) plywood) Battens Monier Lifetile Villa, Roil, and Capri Tile 2-10d Ring Shank Nails 1-10d Smooth or Screw Shank Nail 2-10d Smooth or Screw Shank Nails 27.8 37.4 28.8 8.8 11.8 4.1 16.4 21.9 7.1 1 #8 Screw 2 #8 Screw 25.8 25.8 22.9 47.1 47.1 49.1 1-10d Smooth or Screw Shank Nail (Field Clip) 1-10d Smooth or Screw Shank Nail (Eave Clip) 2-10d Smooth or Screw Shank Nails (Field Clip) 2-10d Smooth or Screw Shank Nails (Eave Clip) 24.3 24.3 24.2 19.0 19.0 22.1 35.5 35.5 34.8 31.9 31.9 32.2 2-10d Rin. Shank Nails' 43.0 installation with a 4" tile headlap and fastemers are located a min. of 2' 0 5 Frank Zuloaga, RC Roofing Product Control Examiner NIONIER LIFETILE LLC 4 ACCEP- T:jNCE No. : 99- 1012.02 APPROVED :December 30, 1999 EXPIRES :December 16, 2002 NOTICE OF ACCEPTANCE: STANDARD CONDITIONS Table 4: Attachment Resistance Expressed as a Moment M, (ft -ibf) for Two Patty Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Monier Lifetiie Villa, Roll, and Capri Tile Adhesive 26.13 2 See manufactures component approval for installation requirements. 3 Flexible Products Company Tile8ond Average weight per patty 11.4 grams. Polyfoam Product, Inc. Average weight per patty 8 grams. Table 4A: Attachment Resistance Expressed as a Moment - M, (ft-tbf) for Single Patty Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Monier Lifetile Villa, Roll, and Capri Tile Polyfoam PolyProM 86.614 Polyfoam PoiyProTM' 45.55 4 Large paddy placement of 54grams of PolyProTM'. 5 Medium • addy placement of 2 -• rams of Pol Pror". Table 4B: Attachment Resistance Expressed as a Moment - M, (ft-Ibf) for Mortar Set Systems Tile Profile Tile Application Attachment Resistance Monier Lifetile Villa, Roll, and Capri Tile Mortar Set' 20.60 5 LABELING All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo, or foIlowingjtaternent: "Miami-Dade County Product Control Approved ". 6. BUILDING PERMIT REQUIREMENTS 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance. . 6.1.2 Any other documents required by the Building Official or the South Florida Building Code (SFBC) in order to properly evaluate the installation of this system. uloaga. RRC Rooting Product Control Examiner MONTER LIFETILE LLC ACCEPTANCE•N9.: 99- 1012.02 APPROVED :December 30, 1999 EXPIRES :December 16, 2002 NOTICE OF ACCEPTANCE: STANDARD CONDITIONS PROFILE DRAWINGS NAL HOLE MONIER LIFETILE VILLA CONCRETE ROOF TILE MONIER LIFETILE ROLL CONCRETE ROOF TILE Frank Zutoaga, RRC Roofing Product Control Examiner MONTER LIFETILE LLC Oa ACCEPTANCE No. : 99-1012.02 APPROVED :December 30, 1999 EXPIRES :December 16, 2002 NOTICE OF ACCEPTANCE: STANDARD CONDITIONS MONIER LIFETILE CAPRI CONCRETE ROOF TILE eaga, !lac Rooting Product Control Examiner MONT, L1FETILE LLC ACCEPTANCE No.: 99- 1012.02 APPROVED EXPIRES :December 30, 1999 :December 16, 2002 NOTICE OF ACCF„P 'ANCE: 'ANDARD CONDXT O s I N Renewal of this Acceptance (approval) shalt be considered after a renewal application has been filed and the original submitted documents, including test - supporting data, engineering documents, are no older than eight (S) years.. 2. Any and all approved products shall be peemanendy labeled with the manufacturer's name, city, state, and the following statement: "Miami 1Dade County Product Control Approval ", or as specifically stated in the specific conditions of this Acceptance. Renewals of Acceptance will not be considered if a. There has been a change in the South Florida Building Code affecting the evaluation of this product and the product is not in compliance with the code changes. b. The product is no longerthe same product (identical) as the one originally approved. c_ if the Acceptance :holder has not complied with all the requirements of this acceptance, including the correct installation of the product. d. The engineer who originally prepared, signed and sealed the required documentation initially submitted, is no longer practicing the engineering profession_ 4_ Any revision or change in the materials, use, and/or manufacture of the product or process soh lll automatically be cause for termination of this Acceptance, unless prior written approval requested, (through the flints of a revision application with appropriate fee) and granted by this office. 5. Any of the following shall also be grounds for removal of this Acceptance: a. Unsatisfactory performance of this product or prod• for sates. advertising or any b. Misuse of this Acceptance as an eadorsernent of any product, other purposes. and 6. The Notice of Acceptance Number preceded by the words Miami-Dade Cotmty, Florid'f the followed by the expiration date may be displayed in advertising literature_ 1.f any portion o Notice of Acceptance is displayed, then it'shatt be done in its entirety. 7. A copy of this Acceptance as well as approved drawings and other documents, where it applies., shall be prOvided to the user by the manufacturer or its distributors and shall be available for inspection ar the job site at all time. The engineer need. not reseal the copies. 8. Failure to comply with any section of this Acceptance shall be cause for termination and removal of Acceptance. 9. This Notice of Acceptance consists of pages 1. through 8 and this last page 9. El• OF 'I WS ACCEFTAN 3. 9 ran 2rzIoaga, RAC Roofing Product Control Examiner • Miami Shores Village 10050 NE 2nd Avenue Phone: 305 - 795 -2204 Printed: 10 /31/2002 Applicant: CARMELLE Owner: JULMISSE JOB ADDRESS: 24 NW 109 Contractor HOME DEPOT INSTALLED ROOFING Local Phone: 561- 272 -5554 Parcel # 1121360110190 Building Permit Permit Number: BP2002 -18 JULMISSE CARMELLE ST aVY of 1krt, Owner Is Responsible for Maintenance of All Village Sidewalks as per Village of Miami Shores Code of.Ordinances, including Driveway • Caused By Current Construction Midi, Contractor's Address: 207 KELSEY LANE SUITE G Legal Description: DUNNINGS MIAMI SHORES EXT NO 7 PB 52 -33 LOT 3 Fees: FEE2002 -6164 FEE2002 -6165 FEE2002 -6166 Description Building Fee CCF Buildier's Bond Total Fees: Amount $187.50 $9.00 $300.00 $496.50 Total Fees: $496.50 Total Receipts: $0.00 Permit Status: Approved Permit Expiration: 4/29/2003 Construction Value: $14,300.00 Work: RE ROOF REMOVE EXIST TILES AND REPLACE W MONIER CAPRI NEVEDA CLAY COLORTHRU BLK If there is no permit package accessible on the job -site for inspectors to verify, there will be no inspections. Re- inspection fee is $50.00, which must be paid in advance before calling for another inspection. This Permit is granted to the contractor or builder named above to construct the building or to install the equipment or device described in the application herefor in strict compliance with all ordinances pertaining thereto and with the understanding that the work will be performed in compliance with any plans, drawings, statements or specifications that may have been submitted to and approved by the proper municipal authorities. This Permit may be revoked at any time if the work is not done in compliance with such ordinances or if the plans are changed without authorization. A further condition upon which this permit is granted is the understanding that the contractor or builder named above assumes the responsibility for a thorough knowledge of the ordinances and regulations pertaining to the work covered hereby whether shown on the plans or drawings or in the statements or specifications and that he assumes responsibility for work done by his agents. s ;; ants or employ Signed (INSPECTOR) BY: In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responisibility for all work done by either myself, my agent. servants or employes. (Contractor or Builder) BY: