RF-07-2228Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 nsl n Numbe NSP -66 Inspection Date: 11/20/2007 Inspector: Grande, Claudio PermtNu Owner: RODRIGUEZ, IVAN Job Address: 390 102 Street NE Miami Shores Village, FL Project: <NONE> Block: Contractor: ISAACS ROOFING & INSULATION CORP 7-2228 Permit Type: Roof Inspection Type: Final Roof Work Classification: Roof - New Phone Number Parcel Number 1132060135110 Lot: Phone: (305)234 -5234 Building Department Comments RE -ROOF TILE TO TILE 1 Passed � Inspector Comments CC i i ipR__ l,'s 60 46,-; Z--------- Failed Correction Needed Re- Inspection Fee ($75) No Additional Inspections can be scheduled re- inspection fee is paid. until Monday, November 19, 2007 Page 1 of 2 U.S. SOUTH Engineering & Testing Lab., Inc. 6065 N.W. 167th Street, Suite B -23 • Miami Lakes, Florida 33015 Telephone: (305) 558 -2588 • Fax: (305) 362 -4669 ON -SITE CONCENTRATED UPLIFT LOAD TESTING OF ROOF TILE IN FULL ACCORDANCE WITH METRO -DADE BUILDING CODE COMPILANCE PROTOCOL TAS 106 Project No 09910 SITE SPECIFIC INFORMATION Owner's Name. ' , c- D, _R- 16-4 Permit # i Job Address: `5 C to +1, Roofing Contractor i7' j d +�w�> t Type of Tiled � d —F0Auhdi Approximate Roof Height: feet Type of Access to Roof: Scaffolds Square Footage of Roof: k, 4 ft2 Required Testing Force: 35 lbs. Testing Equipment: Chatillion 100 Date Tested: I � 2. 2-1—P Date Installed: 1 I° 4-" Roof Pitch: r Other TEST RESULTS P = PASS, F = FAIL Test Location Uplift Pull Test(P or F) Test Location Uplift Pull Test(P or 9 Test Location Uplift Pull Test(P or 9 Teal Location Uplift Pun Test(P or 0 1 �j ) 26 r ` 0) 51 76 77 2 C 27 f 3 28 53 78 4 29 54 79 5 30 55 80 6 31 - 56 81 7 32 57 82 8 33 58 83 9 34 59 84 10 35 60 85 11 38 61 88 12 37 82 87 13 38 63 88 14 39 84 89 \ 15 40 65 90 16 41 86 91 17 42 67 92 18 43 68 93 19 44 69 94 20 45 70 95 21 48 71 96 22 47 72 97 23 48 73 98 24 49 74 99 25 50 _ 75 100 IN ACCORDANCE WITH TH CRITERIA OF PROTOCOL TAS 108, THIS ROOF ASSEMBLY HAS PASSED THE STATIC UPLIFT QUALITY CONTROL TE THIS REP •-'. S = ITTED BY: ' 1600.00,,, (<- P.E. --' 1.: — ei Lab Certification # 98 -0608 State of FL Certificate Authorization # 4100 Sketch of Roof Job I ai Ail ° 40 F1 Sheet Number Hof Contractor -Ft t; Checked By Scale ■■■■■■■■■■■■■■M■■ ■■■■■.■■■■■■ IIIOP!!'!'!IuIIOhIIHIIIHhI MMEMINEMWOMMEMEMMEMEOHNIMMOMME MEMMEMARROMMONEMENNWMAUMEMMMEMM lummmummsagegmmuspommummummil Immumminc - mimmirtmonnommumm mmummumnsaillgama immumummil mommummmommmummummitennommumm mmilmnimmammirmammammummumm 1111111111.11111111111 IIIIIIIIIIIIIIIIIIIIIIIIIIIIIII IIMMEMMEMIMMEMMEMMEMINIMMIIMMIMMEM MEMINIMMEMMENIMMEMINIMMEIMMEMINIM Notes: RE: Permit # Miami szetid'e Vicep Vefra'ztme ee 10050 NE 2nd Ave Miami Shores, Fl 33138 Phone 305-795-2204; Fax 305-756-8972 www.miamishoresvillage.com DATE: it ° &o • o-7.- INSPECTION AFFIDAVIT , licensed as a (n (Print name and circle License Type) License #: s'S•C; On or about Contractor / FS 468 Building Inspector (Date & time) econda water barrier rk at laamwmi Novo 72001, BY: ngineer / Architect, , I did personally inspect tr e roof deck nailing nd /or 3e3 o ak■C /02 Sr; (Complete Job Site Address) Based upon that examination I have determined the installation was done according to the Hurricane Mitigation Retrofit Manual (Based on 553.844 F.S) Signature State of Florida County of Dade: The undersigned, being the first duly sworn, deposes and says that he /she is the contractor for the above property mentioned. Sworn to and subscribed before me this 1 Notary Public, Sate of Florida at Large day of N1011/ /9-001 s C,1 ,0 1- �� c!?.....,, G4v-. ci• pection. or each *General, Building, Residential, or Roofing Contractors or any individual certified under 468 F.S. to1'n Include photographs of each plane of the roof with permit # and address # clearly shown marked on t -�o inspection Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 BUILDING PERMIT APPLICATION FBC 2004 Permit Type (circle): Building Owner's Name (Fee Simple Titleholder) 1.J U4 . i 13 Q— e.DT —iotuC `— Phone # Owner's Address Je't c7 1.1.70. . L02_ c l City M . �- - SILMIZS State pi,. Zip Tenant/Lessee Name Phone # Permit No.'g. , Igt NOV 0 2 2007 BY: i -A2 3 Master Permit No. Job Address (where the work is being done) 3c1 0 02 sr City Miami Shores Village County Miami -Dade Zip FOLIO / PARCEL # / Is Building Historically Designated YES NO • Contractor's Company Name S44A C 5 12,F,- ,�• � �� Contractor's Address ? ! (p City + mot 4 State .rr Qualifier Name Phone # 6P .915(i) Zip Phone # State Certificate or Registration No. Le-c., 15 25 SS (p Certificate of Competency No. Architect/Engineer's Name (if applicable) Ler A— Value of Work For this Permit $ 7 0.‹.0 Type of Work: ['Addition ['Alteration Describe Work: 04- Phone # Square / Linear Footage Of Work: 1, ['New v � Repair/Replace . [' Demolition ************************* ** * * * ** ** *****Feesb�******* **�x * * ** Submittal Fee $ Permit Fee $ . CCF $ 4.10 CO /CC Notary $ 5.0 Training/Education Technology ' �� ,/� Trainin ucation Fee $ � - Technolo Fee $ �'� ' C� Scanning $ 9, 00 Radon $ DPBR $ Zoning $ Bond $ Code Enforcement $ Double Fee $ Structural Review. $ Total Fee Now Due $ 501 - See Reverse side -, Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be ! proved and �reinspection fee will be charged. Signature Owner or Agent The for•,.oi F. i strument was acknowledged before e this ofR 1 -. 0mby V IulQL. who is personally kn.twnn to me or who has produced 26 2Z� Identification and who did take � l.�5 C�S'p4C.)). et '1, oa >° oo Sct'4o�o G4,0 NOTARY PUBLIC: Sign: Print: My Commission Expires: APPLICATION APPROVED BY: (Revised 07/10/07) Signature Contractor The foregoi g 'nstrument was acknow edged be .re me thi day of , 20[, by 1/1 who is personally known to me or who has produced ti as identification and who did t ry0 saw NOTARY PUBLIC: Sign: Print: My Commission Expires: •/-7 Plans Examiner Engineer Zoning This Instru ent Prepa Name -1-4C4,-Ac Address C :Fhd 2C07R1067888 OR RECORDED 11/05/2007 HARVEY RUVIN CLERK ST PAGE Permit No. 1 11111111111 11111111111111111111111111111 1111 BK 26031 Ps ps) 15:09:50 OF COURT? MIAMI—DADE COUNTY? FLORIDA NOTICE OF COMMENCEMENT Tax Folio No. STATE OF COUNTY OF THE UNDERSIGNED hereby gives notice that improvement will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement. 1. Description of property: (legal description of property, and street address if available) t- lO�sr °(y 0 - o Low g? 0 2. General description of improvement: "f. (c rb "Tr cc 3. Owner information a. Name and address: �,a,J(j�r.r: r �s9t� ,►.: b. Interest in property: a6'— 4' - 006 /0051 '/ A-4 ,SAA,frt5 �f c. Name and address of fee simple titleholder (if other than owner): 3313 4. Contractor. �sA,AG� ®Jr . fir, a. Name and address: '2-4$ �J T ° ///� b. Phone number: �r "7. LT) � L (0 5. Surety a. Name and address: b. Amount of bond $ c. Phone number: 6. Lender a. Name and address: b. Phone number. ,40 7. Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)7., Florida Statutes: a. Name and address: y'"' l� b. Phone number. B. In addition to himself, Owner designates the following person(s) to receive a copy of the Lienor's Notice as provided In Section 713.13(1)(b), Florida Statutes: a. Name and address: b. Phone number. 9. Expiration date of notice of commencement (the expiration date is 1 year from the date of recording unless a different date is specified) WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART I, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSU WITH YOUR L -VDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COM EM NT. T ' r� Utv�.a �nH9)z -z= er or Owner's Au orized Officer /Director Signet's o 0 Partner /Manag er jSiignatory's / ce 1 lX/ ay of Flay r .UIl�11�' The f rego ng instru nt was acknowledged before me this dear) by UiC1)l,tr.Q.�. (type of name o person) as (name of party on authority, ...e.g o cer, s ee, a amey n ac behalf of whom instrument was executed). '� t ■ e 1 J ad a103 MQ �� � i of person { officer, trustee, attorney fact) for NOTart nimicimaTE OF FLORIDA Claudia V. CubilloS ':Commission #DD717923 .y...,...., Expires: SEP. 23, 2011 BONDED THRu MANTIC BONDING CO.,1NC. Signa re of Notary Public — State of Florida Print, Type, or Stamp Commissioned Name of Notary Public Commission Number L�Personally Known _ or Produced Identification t) ft 16 Verification Pursuant to Section 92.525. Florida Statutes 02- 2Co fau Under penalties of perjury, I declare that I have read the foregoing and that the facts stated in It are true to the best of my knowledge and belief. Signature of Natural Person Signing Above CITIZENS PROPERTY INSURANCE CORPORATION, WIND ONLY POLICY 6676 Corporate Center Parkway, Jacksonville, Florida 32216 -0973 INSURED NAME AND ADDRESS RODRIGUEZ, IVAN A. AND VIVIAN D. 390 NE 102ND ST MIAMI SHORES, FL 33138 POLICY TERM 4CITIZENS eennut rorvuec. m�vad+ms THIS IS A DWELLING 6/10/2007 TO 6/10/2008 AT 12:01 A.M. (EST) CITIZENS POLICY NO. 771804 INCEPTION DATE EXPIRATION DATE This is your Policy Declaration Page - This is not a Bill - DO NOT PAY PAGE 3 Item No • AMOUNT of INsuRpNCE .::. DEDUCTIBLES: Teriitory : Premium .. • -Building :Contents - 1 2 249,000 115,000 $4,980 (2%)/$500 T -24 2,803 TWO STORY MASONRY 1 UNIT DWELLING LOC: 390 NE 102ND ST MIAMI SHORES, DADE FL 33138 -2429 2 story, Masonry, gable roof, roof covering: Non -FBC Equivalent, Roof Deck Attachment -A, roof wall connection: Toe -Nails and Year Built Verified: No -1940 Homestead Property If the above characteristics do not accurately describe your dwelling, contact your agent. 10,000 0 $500/$500 T -34 6 SWIMMING POOL Total Coverage amount: $374,000 Total Premium amount: $3,307 L �ricane Premium $2,742 N- Hurricane Premium $67 7.,--Lx Exempt Surcharge $49 2005 Florida Hurricane Catastrophe Fund Emergency Assessment Catastrophe Reinsurance Surcharge $28 $421 Su1cet to Form No(s) : Mor:os ifLoss Payee: MORTGAGEE /LOSS PAYEES LIST ON ADDITIONAL PAGE Agent: CLAWSON & COMPANY INC 0435 2731 EXECUTIVE PARK DRIVE SUITE # 8 WESTON, FL 33331 111111111111 Payor: WASHINGTON MUTUAL BANK ISAOA /ATIMA P.O. BOX 100564 FLORENCE, SC 29501 Date: 5/21/2007 POLICY DECLARATION - INSURED COPY QSY R 40111 3114 000330 Mame Seenea ` flap'may Vefra ti 10050 NE 2nd Ave * Miami Shores, FI 33138 Phone 305-795-2204; Fax 305-756-8972 OWNERS'S AFFIDAVIT OF EXEMPTION ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR EXISTING SITE- BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES PERSUANT TO SECTION 553.844 F.S. To: Miami Shores Village Building Department Date: 11/05/6#7 9 9 p 10050 NE 2nd Ave Miami Shores, FI 33138 Re: Owner's Name: ►" i 1(Q `1 a - Z 4O I(dZI 6 Property Address: 590 AJE / 62 P5 , Roofing Permit Number: Dear Building Official 1 ` 040 Kb d n certify that I am not required to retrofit the roof to wall connections of my building because: )1i., just valuation for the structure for purpose of ad valorem taxation is less than $300,000.00. Please attach proof of ad valorem taxation. 0 The building was constructed in compliance with the provisions of the Florida Building Code (FBC) or with the provisions of 199a - dition of the South Florida Building Code (1994 SFBC) Signature State of Florida County of Dade Lilt Oa In 2cozct Print Name j2. 06(0_0 0 The undersigned, being the first duly sworn, deposes and says that he /she is the contractor for the above property mentioned. Sworn to and subscribed before me this 3 day of KJOU Notary Public, Sate of Florida at Large 6 l ) � * When the just valuation of the structure for purpose of ad valorem taxation is equal to or more than $300,000.00, and the building was not constructed with FBC nor a 1994 SFBC. Then you must provide a building application from a General Contractor for the Roof to Wall connection Hurricane Mitigation. i �Y UBLIC -STATE OF FLORIDA so"'"'s., Claudia V. Cubillos ,f jCommission #DD717923 .,.,,,,,,. Expires: SEP. 23, 2011 BONDED THE ATLANTIC BONDING CO., INC. ROOF ASSEMBLIES AND ROOFTOP STRUCTURES MOYEEVM Florida Building Code Edition 2004 Nov0 2 Z0i-1 High - Velocity Hurricane Zone Uniform Permit Application Form. BY: - - - -- Section A (General Information) Master Permit No. 1,� Process No. Contractor's Name E S ,®A -c5 71�-3a C: i.Y of Job Address 2C;0 MC 102, ST CROOF CATEGORY w pe ❑ Mechanically Fastened Tile ph c ❑ Metal Panel/Shingles In s ❑ C Rom i C�3'Rerooting ❑ Recovering ❑ Prescriptive BUR -RAS 150 ROOF TYPE ROOF SYSTEM INFORMATION @f Mrtar /Adhesi ❑ Wood Shingle t O U is ❑ Repair ❑ Maintenance Low Slope Roof Area (SF) 01A- Steep Sloped Roof Area (SF) t'4O 0 Total (SF) `Ao Section B (Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. • • • •• • • • •••• • • • • • •• • • • • • • • • • • •• • • • • • • • • • • • • • •••• • • • • •••• •1 • • • • • •• • • • • • • • • •••• • • ••• • • • • • •• r-EalAt. 12541- 15.32 FLORIDA BUILDING CODE — BUILDING N 0 Z Z D 0 D1 TO CO JD COU 0 m �I ii BY liami Shores Villa #: - 0 -- 4 -D{ het t O U is ❑ Repair ❑ Maintenance Low Slope Roof Area (SF) 01A- Steep Sloped Roof Area (SF) t'4O 0 Total (SF) `Ao Section B (Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. • • • •• • • • •••• • • • • • •• • • • • • • • • • • •• • • • • • • • • • • • • • •••• • • • • •••• •1 • • • • • •• • • • • • • • • •••• • • ••• • • • • • •• r-EalAt. 12541- 15.32 FLORIDA BUILDING CODE — BUILDING ROOF ASSEMBUES AND ROOFTOP STRUCTURES Florida Building Code Edition 2004 High - Velocity Hurricane Zone Uniform Permit Application Form. Section D (Steep Sloped Roof System) Roof System Manufacturer: e Ng Notice of Acceptance Number: D(o.- Ou,pCo.oS. Minimum Design Wind Pressures, If Applicable (From RAS 127 or CalculationsP1)• : 4s P2: R S ,I P3: ciS , i Maximum Design Pressure (From the Product Approval Specific Syste Li°'`1/4 - oL. . Roof Slope: :12 Steep Sloped Roof System Description Deck Type: Type Underlayment: V Zrtk- Insulation: Fire Barrier: Ridge Ventilation? Fastener Type & Spacing: Imo(A- Mean Roof Height: 2- Adhesive Type: Type Cap Sheet: • • • • • •• • • • " a' •�I •...__- ..., • ("J • ... Roof Covering: - � � Type & Size Drip 3� Edge: 15.34 FLORIDA BUILDING CODE — BUILDING ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Florida Building Code Edition 2004 High-Velocity Hurricane Zone Uniform Permit Application Form. Section E (Tile Calculations) For Moment based tile systems. choose either Method 1 or 2. Compare the values for Mr with the values from Mt. If the Mf values are greater than or equal to the Mr values, for each area of the roof, then the tile attachment method is acceptable. 4S Method 1 C "MGooment Based Tile Calculation Per AS 127" (P1::p�4S xA �`il= ' °SG)-Mg:Co mril -535 Product Approval Mr4.®'Lk (PZ -1C ' x X • 113 1 = f ') - Mg: (9 ,e ti = Mr2 Product Approval Mr 1+l (P3: 35 x A • k ' _ �, - Mg: (o C 1= Mr3 t Product Approval Mr 40.4 • Method 2 "Simplified Tile Calculations Per Table Below" Required Moment of Resistance (Mr) From Table Below Product Approval Mr Mr required Moment Resistance* Mean ' • •f Height -3 Roof lope ,1, 15' 20' 25' 30' 40' 2:12 34.4 36.5 38.2 39.7 42.2 3:12 32.2 34.4 36.0 37 4 39.8 4:12 30.4 32.2 33.8 5.1 37.3 5:12 28.4 30.1 31.6 32.8 34.9 6:12 26.4 28.0 29.4 30.5 32.4 7:12 .4 25.9 _ 27.1/ 28.2 30.0 "Must be used in conjunction with a list of mo r nt based tile systems endorsed by tb (roward County Board of Rules and Appeals. For Uplift based tile systems use Method 3. Comp he values for F' with the ve s for Fr. If the F' values are greater than or equal to the Fr values, for each area of the roof, then the tile attachment meth is acceptable. Method 3 "Mom t Based T le Calculations Per RAS 127" (Pr: (P2: (P3: x L = x w: _ ) - W: cos B = Fri Product Approval F' xL xL = xw:= ) -W: xw:= os B = Ft2 Product Approval F' = Fr3 Product Approval F' • •• •• •• • • •• I I• ••• •• • ▪ • • • • • FLORIDA BUILDING CODE - BUILDING 15.35 here to Obtain nformatlon • • • • • • ••• • Description Symbol - Where to find • • • • • • • Design Pressure PI or _ or P3 • RAS 127 Table I or by an engin ring analysis prepared by PE base* enW16r€47 • Mean Roof Height H Job Site • •••• • • •e Roof Slope 9 Job Site • • •• • Aerodynamic Multip; r X Product Approval • • • • • • • • • t Restoring Moment -.ue to ravity Mg Product Approval • • • • • • I ••11 Attachment ^ esistance Mr Product Approval • • • • • • • • ••t •••1 Required Mome, Resistance Me Calculated Minim ; Attachment Resistance F' Product Approval Required lift Resistance Fr Calculated Average Tile Weight W Product Approval Tile Dimensions L = length W = width Product Approval All calculations must be submitted to the building official at the time of permit application. • •• •• •• • • •• I I• ••• •• • ▪ • • • • • FLORIDA BUILDING CODE - BUILDING 15.35 SECTION 1524 HIGH - VELOCITY HURRICANE ZONES — REQUIRED OWNERS N... Page 1 of 2 SECTION 1524 HIGH - VELOCITY HURRICANE ZONES — REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS 1524.1 Scope. As it pertains to this section, it is the responsibility of the roofing contractor to provide the owner with the required roofing permit, and to explain to the owner the content of this section. The provisions of Chapter 15 of the Florida Building Code, Building govern the minimum requirements and standards of the industry for roofing system installations. Additionally, the following items should be addressed as part of the agreement between the owner and the contractor. The owner's initial in the designated space indicates that the item has been explained. 1. Aesthetics - workmanship: The workmanship provisions of Chapter 1.5 (High - Velocity Hurricane Zone) are for the purpose of providing that the roofing system meets the wind resistance and water intrusion performance standards. Aesthetics (appearance) are not a consideration with respect to workmanship provisions. Aesthetic issues such as color or architectural appearance, that are not part of a zoning code, should be addressed as part of the agreement between the owner and the contractor. 2. Renailing wood decks: When replacing roofing, the existing wood roof deck may have to be renailed in accordance with the current provisions of Chapter 16 (High - Velocity Hurricane Zones) of the. (The roof deck is usually concealed prior to removing the existing roof system.) 3. Common roofs: Common roofs are those which have no visible delineation between neighboring units (i.e., townhouses, condominiums, etc.). In buildings with common roofs, the roofing contractor and /or owner should notify the occupants of adjacent units of roofing work to be performed. 4. Exposed ceilings: Exposed, open beam ceilings are where the underside of the roof decking can be viewed from below. The owner may wish to maintain the . . architectural appearance; therefore, roofing nail penetrations of the underside o M decking may not be acceptable. The owner provides the option of maifltairfing • appearance. • • • ZA 5. Ponding water: The current roof system and /or deck of the buildifirmay rust drain • • well and may cause water to pond (accumulate) in low -lying areas of the •roof. Po'hdihlg • • can be an indication of structural distress and may require the revievtOAProfessior:al structural engineer. Ponding may shorten the life expectancy and pellapance of the •• new roofing system. Ponding conditions may not be evident until the:oriOirtai rootog.• • system is removed. Ponding conditions should be corrected. •••• • • • •• • ••• • . 6. Overflow scuppers (wall outlets): It is required that rainwater flow off so that de e4e_. roof is not overloaded from a buildup of water. Perimeter /edge walls or other roof extensions may block this discharge if overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in accordance with the requirements of: Chapter 15 and 16 herein and the Florida Building Code, Plumbing. 7. Ventilation: Most roof structures should have some ability to vent natural airflow through the interior of the structural assembly (the building itself). The existing amount of attic ventilation shall not be reduced. It may be beneficial to consider additional venting which can result in extending the service life of the roof. http: // ecodes .iccsafe.org /icce /gateway.dll /Florida %20Custom /Bui1d2004 FL /294/318 ?f =te... 11/1/2007 MIAMI•D�ADE COUNTY BUILDING CODE COMPLIANCE OFFICE (BCCO) PRODUCT CONTROL DIVISION NOTICE OF ACCEPTANCE (NOA) Entegra Sales, Inc. 819 N. Federal Highway, Suite 300 Stuart, FL. 34994 MIAMI-DADE COUNTY, FLORIDA METRO -DADS FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 MIAMI, FLORIDA 33130 -1563 (305) 375 -2901 FAX (305) 375 -2908 www.buildinacodeonline.com SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by Miami -Dade County Product Control Division and accepted by the Board of Rules and Appeals (BORA) to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Division that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION: Bermuda Concrete Flat Roof Tile LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed aril there has WA fit)* change in the applicable building code negatively affecting the performance of this product...' : • • TERMINATION of this NOA will occur after the expiration date or if there has been a re'Ag'io!'or chalige in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an enaor: ement of an. product, for sales, advertising or any other purposes shall automatically terminate this NOA+ rg 1are to enn igy with any section of this NOA shall be cause for termination and removal of NOA. • • • ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida,• and ff'ollowed by the expiration date may be displayed in advertising literature. If any portion of the NOA •dip yed, then it shall be done in its entirety. • " • INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacttRg; er tts dist5i�ittorr and shall be available for inspection at the job site at the request of the Building Official. • ' • • This replaces NOA # 06- 0610.06 and consists of pages 1 through 6 The submitted documentation was reviewed by Alex Tigera. NOA No. 06- 0606.05 Expiration Date: 06/07/11 Approval Date: 07 /06/06 Page 1 of 6 ...... • .• • • • • ROOFING ASSEMBLY APPROVAL Category: Roofing Sub Category: Roofing Tiles Material: Concrete 1. SCOPE This revises a roofing system using Entegra Flat Concrete Roof Tile, as manufactured Entegra Roof Tile Corporation described in Section 2 of this Notice of Acceptance, designed to comply with the Florida Building Code, 2004 Edition for High Velocity Hurricane Zone. For the locations where the pressure requirements, as determined by applicable Building Code, does not exceed the design pressure values obtain by calculations in compliance with RAS 127 using the values listed in section 4 herein. The attachment calculations shall be done as a moment based system. 2. PRODUCT DESCRIPTION Manufactured by Applicant Entegra Flat Tile Trim Pieces 2.1 Product Dimensions 1 =16" w = 10" 1 -1/4" thick 1 = varies w = varies varying thickness Test Specifications TAS 112 TAS 112 Product Description Flat profile, interlocking, high pressure extruded concrete roof tile equipped with two nail holes. For direct deck or batten nail on, mortar or adhesive set applications. Accessory trim, concrete roof pieces for use at hips, rakes, ridges and valley terminations. Manufactured for each tile profile. COMPONENTS OR PRODUCTS MANUFACTURED BY OTHERS Test Product Dimensions Specifications Description Rainproof II 30" x 75' roll TAS 104 Single ply, nail -on 36" x 75' roll underlayment with or 2" self - adhering top 60" x 75' roll edge. Ice and Water 36" x 75' roll TAS 103 Self - adhering Shield underlayment • • • • • .jVIauufactu1 f••• • • •Protect -O- Wrap,.. • •••• Inc. •••• (W14f e1rrent ZTO.A) . •. .• • •. • • • • • W.R. °Grace &.o (witty cgrrent NOVA) NOA No. 06- 0606.05 Expiration Date: 06 /07/11 Approval Date: 07 /06/06 Page 2 of 6 Product Dimensions Wood Battens Tile Nails Tile Screws Roof Tile Mortar ( "TileTiteTM") Roof Tile Mortar ( "Quikrete® Roof Tile Mortar #1140 ") Roof Tile Mortar ("BONSAL® Roof Tile Mortar Mix") Roof Tile Adhesive ( "Polypro® A11160 ") Vertical Min. 1 "x 4" Horizontal Min. 1 "x 4" for use with vertical battens or Min. 1"x 2" for use alone Min. 10dx 3" #8x 21 /z" long 0.335" head dia. 0.131" shank dia. 0.175" screw thread dia. N/A N/A N/A N/A Roof Tile Adhesive Factory premixed TileBond canisters Test Specifications Wood Preservers Institute LP — 2 TAS 114 Appendix E TAS 114 Appendix E TAS 123 TAS 123 TAS 123 See PCA See PCA Product Description Salt pressure treated or decay resistant lumber battens Corrosion resistant screw or smooth shank nails Corrosion resistant, coated, square drive, galvanized, coarse thread wood screws Prepared mortar mix designed for mortar set roof tile applications. Prepared mortar mix designed for mortar set roof tile applications. Prepared mortar mix designed for mortar set roof tile applications. Two component polyurethane adhesive designed for adhesive set roof tile applications. Single component polyurethane foam roof tile adhesive Manufacturer generic generic generic Bermuda Roof Company, Inc. with current PCA Quikrete Construction Products with Current PCA W. R. Bonsai Co. with current !CA • • . • • • •• • • • • • Pglyjfvam Prod:: rsj • •Inc. • • • • •• •• •• • • • • • •• • • • • • •••• • •.•. • • • Inexittle Proflt7et,s (with current NOA'' NOA No. 06- 0606.05 Expiration Date: 06/07/11 Approval Date: 07 /06/06 Page 3 of 6 Product Dimensions Hurricane Clip & Fasteners Clips Min. 1h" width Min. 0.060" thick Clip Fasteners Min. 8d x 11/4" 3. LIMITATIONS Test Specifications TAS 114 Appendix E Product Description Manufacturer Corrosion resistant Generic clips with corrosion resistant nails. 3.1 Fire classification is not part of this acceptance. 3.2 For mortar or adhesive set tile applications, a static field uplift test shall be performed in accordance with RAS 106. 3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test in accordance with TAS 112, appendix `A'. Such testing shall be submitted to the Building Code Compliance Office for review. 3.4 Minimum underlayments shall be in compliance with the applicable Roofing Applications Standards listed section 4.1 herein. 3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature. 3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with applicable Building Code. 4. INSTALLATION 4.1.1 Entegra `Flat' Concrete Roof Tile and its components shall be installed in strict compliance with Miami Dade County Roofing Application Standard RAS 118, RAS 119, and RAS 120. 4.2 Data For Attachment Calculations • Table 1: Average Weight (W) and Dimensions (I x w) : ••• • Tile Profile Weight -W (Ibf) Length -I (ft) • • Nyidth -w 1ftj"' • Entegra Flat Tile 9.7 1.33 • • • • .833 •••• • • •••• • '0 •• • • • Table 2: Aerod namic Multi • filers - A, ft • • • • • • Tile X(ft3) :Xfit; •••• Profile Batten Application Direct Deck ApplicatiPfl ' Entegra Flat Tile 0.189 •410 ••• NOA No. 06- 0606.05 Expiration Date: 06/07/11 Approval Date: 07/06/06 Page 4 of 6 Table 3: Restoring Moments due to Gravity - MA (ft-Ibf) Tile Profile 3 ":12" 4 ":12" 5 ":12" 6 ":12" 7 ":12" or greater Entegra Flat Tile Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck 6.53 6.97 6.43 6.86 6.29 6.71 6.14 6.54 5.97 N/A Table 4: Attachment Resistance Expressed as a Moment - M1 (ft-lbf) for Nail -On Systems Tile Profile Fastener Type Direct Deck (min 15132" plywood) Direct Deck (min. 19/32" plywood) Battens Entegra Flat Tile 2 -10d Ring Shank Nails 30.9 38.1 17.2 1 -10d Smooth or Screw Shank Nail 7.3 9.8 4.9 2 -10d Smooth or Screw Shank Nails 14.0 18.8 7.4 1 #8 Screw 30.8 30.8 18.2 2 #8 Screw 51.7 51.7 24.4 1 -10d Smooth or Screw Shank Nail (Field Clip) 24.3 24.3 24.2 1 -10d Smooth or Screw Shank Nail (Eave Clip) 19.0 19.0 22.1 2 -10d Smooth or Screw Shank Nails (Field Clip) 35.5 35.5 34.8 2 -10d Smooth or Screw Shank Nails (Eave Clip) 31.9 31.9 32.2 2 -10d Ring Shank Nails' 50.3 65.5 48.3 1 Installation with a 4° tile headlap and fastemers are located a min. of 21/x° from head of tile. Table 5: Attachment Resistance Expressed as a Moment M, (ft-lbf) • for Two Patty Adhesive Set Systems • Tile Profile Tile Application Minimum Attaclimeei Resistance .0 • • • i • Entegra Flat Tile Adhesive 3 }0: • • • 2 See manufactures com • • Went a • • royal for installation re • uirements. • • • • • • "" 3 Flexible Products Company TileBond Average weight per patty 13.9 grams. Pol oam Product, Inc. Avera • : wei • ht • : r • a 8 • rams. •••• •• • • • • • • • • 0 • • • • • • • • •• • • .• • • • • • • 0000 • • 0000 • • .0• . . NOA No. 06- 0606.05 Expiration Date: 06/07/11 Approval Date: 07 /06/06 Page 5 of 6 Table 5A: Attachment Resistance Expressed as a Moment - M1 (ft-Ibf) for Sin • le Pa Adhesive Set S stems Tile Profile Tile Application Minimum Attachment Resistance Entegra Flat Tile PolyPro ' 118.94 PolyProTM 40.45 4 Large paddy placement of 45 grams of P0IVProTM. 5 Medium paddy placement of 24 grams of PolyProT"". 5. LABELING All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo, or following statement: "Miami -Dade County Product Control Approved ". 6. BUILDING PERMIT REQUIREMENTS 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance. 6.1.2 Any other documents required by the Building Official or applicable Building Code in order to properly evaluate the installation of this system. PROFILE DRAWING ENTEGRA "FLAT" CONCRETE ROOF TILE 16' i 10' 16' • • • • • • • •• • • • • • END OF THIS ACCEPTANCE • • • • •••• •••• • • • • • • •••• •••• • • •• • • • • • • •• •• • •• • • • • • • • • • •••• • • • • •••• • • • • • •• • ••• • • • • • •• NOA No. 06- 0606.05 Expiration Date: 06/07/11 Approval Date: 07/06/06 Page 6 of 6 MIA MIDADl= BUILDING CODE COMPLIANCE OFFICE (BCCO) PRODUCT CONTROL DIVISION NOTICE OF ACCEPTANCE (NOA) MIAMI -DADE COUNTY, FLORIDA METRO -DADE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 MIAMI, FLORIDA 33130 -1563 (305) 375 -2901 FAX (305) 375 -2908 Polyfoam Products, Inc. 11715 Boudreaux Road Tomball, TX 77375 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by the BCCO and accepted by the Building Code and Product Review Committee to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The BCCO (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BCCO reserves the right to revoke this acceptance, if it is determined by BCCO that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Polypro® AH160 RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of my product, for sales, advertising or any other purposes shall automatically terminate this N04. Failure to c tatply with any section of this NOA shall be cause for termination and removal of NOA. •.. • • • • • • • ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, F.losiL,•and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA i§ divi§yed, then it+.hall be done in its entirety. •••• • • • • •• • • • • • • INSPECTION: A copy of this entire NOA shall be provided to the user by the manufactuf& obits distf!butbfs and shall be available for inspection at the job site at the request of the Building Official. • • This NOA renews NOA No.01- 0521.02 and consists of pages 1 through 7 The submitted documentation was reviewed by Jorge L. Acebo. • • • • • •• • •. • • • • •••• ••• • NOA No.: 06- 0201.02 Expiration Date: 05/10/11 Approval Date: 04/13/06 Page 1 of 7 ROOFING ASSEMBLY APPROVAL: Category: Sub Category: Materials: Roofing Roof tile adhesive Polyurethane SCOPE: This approves Polypro® AH160 as manufactured by Polyfoam Products, Inc. as described in Section 2 of this Notice of Acceptance. For the locations where the design pressure requirements, as determined by applicable building code, does not exceed the design pressure values obtained by calculations in compliance with Roofing Application Standard RAS 127, for use with approved flat, low, and high profile roof tiles system using Polypro® AH 160. Where the attachment calculations are done as a moment based system for single patty placement, and as an uplift based system for double patty systems PRODUCTS MANUFACTURED BY APPLICANT: Product Dimensions Polypro® AH160 N/A Foampro® RTF 1000 N/A ProPack® 30 & 100 N/A Test Specifications TAS 101 Product Description Two component polyurethane foam adhesive Dispensing Equipment Dispensing Equipment PRODUCTS MANUFACTURED BY OTHERS: Any Miami -Dade County Product Control Accepted Roof Tile Assembly having a current NOA which list moment resistance values with the use of Polypro AH160 roof tile adhesive. PHYSICAL PROPERTIES: Property Density Compressive Strength Tensile Strength Water Absorption Moisture Vapor Transmission Dimensional Stability Closed Cell Content Note: Test ASTM D 1622 ASTM D 1621 ASTM D 1623 ASTM D 2127 ASTM E 96 ASTM D 2126 ASTM D 2856 Results 1.6 lbs. /ft.' 18 PSI Parallel to rise 12 PSI Perpendicular to rise 28 PSI Parallel to rise •••• 0.08 Lbs. /Ft2 *••••• • • • • • •• • • • • • • • • •••• • • 3.1 Perm / Inch +0.07% Volume Change @ - 40. °is �'� weep ' • • +6.0% Volume Change @ 158 F! :100% Humidity, 2 weeks • • •••• • • 86% ' • "" • • • •• • ••• • The physical properties listed above are presented as typical average values as determined" by accepted ASTM test methods and are subject to normal manufacturing variation. NOA No.: 06- 0201.02 Expiration Date: 05/10/11 Approval Date: 04/13/06 Page 2 of 7 EVIDENCE SUBMITTED: Test Agency Test Identifier Test Name /Report Date Center for Applied Engineering #94 -060 TAS 101 04/08/94 257818 -1PA TAS 101 12/16/96 25- 7438 -3 SSTD 11 -93 10/25/95 25- 7438 -4 25- 7438 -7 SSTD 11 -93 11/02/95 25 -7492 SSTD 11 -93 12/12/95 Miles Laboratories NB -589 -631 ASTM D 1623 02/01/94 Polymers Division Ramtech Laboratories, Inc. 9637 -92 ASTM E 108 04/30/93 Southwest Research Institute 01 -6743 -011 ASTM E 108 11/16/94 01- 6739- 062b[1] ASTM E 84 01/16/95 Trinity Engineering 7050.02.96 -1 TAS 114 03/14/96 Celotex Corp. Testing Services 528454 -2 -1 TAS 101 10/23/98 528454 -9 -1 528454 -10 -1 520109 -1 TAS 101 12/28/98 520109 -2 520109 -3 520109 -6 520109 -7 520191 -1 TAS 101 03/02/99 520109 -2 -1 LIMITATIONS: • 1. Fire classification is not part of this acceptance. Refer to the Prepared Roof Tile Assen>bly • for fire rating. • •• • • • • • • • • 2. Polypro® AH160 shall solely be used with flat, low, & high tile profiles. • • • •••• •••• • • 3. Minimum underlayment shall be in compliance with the Roofing Application Standa'ra'AS 12d"' •• • • • • • • 4. Roof Tile manufactures acquiring acceptance for the use of Polypro® AH 160 roof ibe: ilhesive with their tile assemblies shall test in accordance with TAS 101. • • • • •••• • • • 5. Roof Tile manufactures acquiring acceptance for the use of HANDI -STICK roof & a'dhesive with • their tile assemblies shall test in accordance with TAS 101 with section 10.4 as modified herein. • •: F'= 2. MS W NOA No.: 06- 0201.02 Expiration Date: 05/10/11 Approval Date: 04/13/06 Page 3 of 7 • • • • •' • • • • • INSTALLATION: 1. Polypro® AH160 may be used with any roof tile assembly having a current NOA that lists uplift resistance values with the use of Polypro® AH160. 2. Polypro® AH160 shall be applied in compliance with the Component Application section and the corresponding Placement Details noted herein. The roof tile assembly's adhesive attachment with the use of Polypro® AH160 shall provide sufficient attachment resistance, expressed as an uplift based system, to meet or exceed the uplift resistance determined in compliance with Miami -Dade County Roofmg Application Standards RAS 127. The adhesive attachment data is noted in the roof tile assembly NOA 3. Polypro® AH160 roof tilt adhesive and its components shall be installed in accordance with Roofmg Application Standard RAS 120, and Polyfoam Products, Inc. Polypro® AH160 Operating Instruction and Maintenance Booklet. 4. Installation must be by a Factory Trained 'Qualified Applicator' approved and licensed by Polyfoam Products, Inc. Polyfoam Products Inc. shall supply a list of approved applicators to the authority having jurisdiction. 5. Calibration of the Foampro® dispensing equipment is required before application of any adhesive. The mix ratio between the "A" component and the "B" component shall be maintained between 1.0- 1.15 (A): 1.0 (B). The dispense timer shall be set to deliver 0.0175 to 0.15 pounds per tile as determined at calibration. No other settings shall be approved. 6. Polypro® AH160 shall be applied with Foampro RTF1000 or ProPack® 30 & 100 dispensing equipment only. 7. Polypro® AH160 shall not be exposed permanently to sunlight. 8. Tiles must be adhered in freshly applied adhesive. Tile must be set within 2 to 3 minutes after Polypro® AH160 has been dispensed. 9. Polypro® AH160 placement and minimum patty weight shall be in accordance with the 'Placement Details' herein. Each generic tile profile requires the specific placement noted herein. Table 1: Adhesive Placement For Each Generic Tile Profile Tile Profile Placement Detail Single Paddy Weight Min. (grams) Two Paddy Weight per paddy Min. (gams) Flat, Low, High Profiles #1 35 Vik • • High Profile (2 Piece Barrel) #1 17 /side on cap and 34 /pan •N/A•• • • Flat, Low, High Profiles #2 24 X l'A ° • Flat, Low, High Profiles #3 •••• . • • • • • LABELING: • • •• •• • • • All Polypro® AH160 containers shall comply with the Standard Conditions listed herein. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or applicable building code in order to properly evaluate the installation of this system. •• • • • •• •••• • • • • ••• • • • ••• • • • • • •• • • • • •••• • • •••• 0 • ••• • • • •• •• NOA No.: 06- 0201.02 Expiration Date: 05/10/11 Approval Date: 04 /13/06 Page 4 of 7 ADHESIVE PLACEMENT DETAIL 1 SINGLE PATTY 1) Place enough adhesive to achieve 11 to 23 t>ptianal2sds for stee square Inches In contact with the pan tile Ph applications To 1 In. From 2) Turn covers upsidedown. Place adhesive 112 In Then install the tile. de edge of cover tile. j Nall through plastic cement Rem top portion of the save C011188 cover Ma Abut to second course of pan tiles. Ensure eave end of pan and cover tiles are flush at save Me. Eava closure )mortar shorn) • • •••• • • •• •• •••• •• • • • • • •• •• • • • • • • • • • • • • • • • • •••• • • • • •••• • • • •• • ••• • • • • •• NOA No.: 06- 0201.02 Expiration Date: 05/10/11 Approval Date: 04/13/06 Page 5 of 7 Nail through plastic cement ADHESIVE PLACEMENT DETAIL 2 SINGLE PATTY Paddy (Beneath Tile) Underlaymen! Nail through plastic cement • • • • • • • • • •• • • • • • • • • • • •••• • s •••• • • • • •••• •••• •• • • • • • • •• •• • •• • • • • • • •••• • • • • •••• • • • • • • • • • •• • ••• • • • • • •• NOA No.: 06- 0201.02 Expiration Date: 05/10/11 Approval Date: 04/13/06 Page 6 of 7 ADHESIVE PLACEMENT DETAIL 3 DOUBLE PATTY Nail through plastic cement Paddy (between tile) Paddy (under tile) 3 in. t x3in. Single paddy on under- layment Single paddy under tile Single paddy on top of file Eave course 2In. X 7 in. medium sae paddy eave Fascia course only Nail through plastic cement Underlayment } 3 in.x 3 In. / 41n. Single paddy under tile Single paddy between tile 2 in. x 7 in. medium size paddy eave course only Single paddy on under - layment Single paddy on top of tile Eave Course Fascia Weephoie Eave closure Drip edge Nail through plastic cement Single paddy between file /A in. x3In Single paddy on underlayment Single paddy on top of the Eave Course Eave Closure 2In. x 7 In. medium size paddy eave course only Fascia END OF THIS ACCEPTANCE • • • • • • • • • .• • • • • • • • • • • •••• •••• • • • • • • • •••• •••• • • •• • • • • • • •• •• • .• • • • • • • • • • •••• • • • • •••• • • • • • •• • ••• • • • NOA No.: 06- 0201.02 Expiration Date: 05/10/11 Approval Date: 04/13/06 Page 7 of 7