Loading...
RF-06-2442Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Inspection Number: INSP-28445 Permit Number: RF -9 -06 -2442 Inspection Date: 10118/2006 Inspector: Grande, Claudio OCT 19 20 Owner: OSTENDORP, THOMAS AND REBECCA Job Address: 261 102 Street NE Miami Shores Village, FL Project: <NONE> Contractor: DALEY ROOFING INC Building Department Comments Passed Permit Type: Roof Inspection Type: Final Roof Work Classification: Roof - New Phone Number Parcel Number 1132060134960 Block: Lot: Phone: (305)754 -9892 Failed Correction Needed Re- Inspection Fee ($75) No Additional Inspections can be scheduled until re- inspection fee is paid. Inspector Comments Tuesday, October 17, 2006 Page 2 of 2 Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 BUILDING : j (TE 7,7 PERMIT APPLICATION FBC 2004 �Ep 29 2006 , Y: -------- - - - - - - -- Permit Type (circle): Building Electrical Plumbing Mechanical Owner's Name (Fee Simple Titleholder) /j'1 ' OS coda Phone # G (p Owner's Address 21,0 / /I /as r Jo/ -61, lert Permit No. 12-F0(9 Z4(42 Master Permit No. r city Ni SkeY.S State Tenant/Lessee Name Zip 33/ s J/ Phone # Job Address (where the work is being done) City Miami Shores Village FOLIO / PARCEL # 21 Ai 6- 102.Sy County Miami -Dade Zip 331 33 Is Building Historically Designated YES NO Contractor's Company Name ./ l &ic- ir3s, NI'i City I v l i CAM State Contractor's Address Phone # 2:c3.4 Zip ; 1 aS Phone # 33y- 151/ 9J Qualifier Name at ik Ve j 1 & State Certificate or Registration No. e s'7/ Certificate of Competency No. Architect/Engineer's Name (if applicable) Phone # Value of Work For this Permit $ 6 Square / Linear Footage Of Work: 0 Type of Work: ❑Addition ['Alteration [New Describe Work: QE- Vapor- air/Replace ❑ Demolition *** * * * ** : * * * * * * * * * * * * * * * * * * * * * * * **** ** Fees * * * * * * * * * ** ** * * * * *** * * * * * *:r * * * *** * *** * * * * ** Submittal Fee $ 0 ° 00 Notary $ Scanning $ Bond $ Permit Fee $ 2j'0 CCF $ 2 43 CO /CC Training/Education Fee $ O ° i_lD Technology Fee $ 6.2 Structural Review. $ Radon $ Code Enforcement $ DPBR $ Zoning $ Double Fee $ Total Fee Now Due $ 2 3O.,4 See Reverse side - OCT 12 PAID C\(;4 f1 Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature_ _ �- - Sign ature -, _ Owner or Ageit ^� Contractor The foregoing instrument was ac ledged befloe�me this a \ The foregoing instrument was acknowledged before me this day o , 206c0, by �`1M%,� \ %1 sc , day of , 20 , by , 1 known to me or who has produced who is personally known to me or who has produced who is personally p NOT Sign: Print: My Commission Expir * * * * * * * * * * * * * * * * ** As identification and who did take an oath. IC: APPLICATION APPROVED BY: (Revised 02/08/06) identification and who did take an oath. NOTARY ' LIC: Sign: Print: My Co ssion Expires: *** * * * * * * * * * * ** * * * * ** * * * * * * ** * * * ** * - * *.***** * * *** DiPlans Examiner Engineer Zoning • NOTICE OF COMMENCEMENT A RECORDED COPY MUST BE POSTED ON THE JOB SITE AT TIME OF FIRST INSPECTION PERMIT NO. TAX FOLIO NO. STATE OF FLORIDA: COUNTY OF MIAMI -DADE: THE UNDERSIGNED hereby gives notice that improvements will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement. 1. Legal description of property and street/address: 111111111111111101111111111111 CFN 2006R1092168 OR Bk 24993 F's 3611; t1ns) RECORDED 10/12/2006 10:50:10 HARVEY RUVINP CLERK OF COURT MIAMI -DADE COUNTYv FLORIDA LAST PAGE 240 f /(cre5 1 /Loom / Stut.i . //33/38' 2. Description of improvement: %._'° s" 3. Owner(s) name and address: -11--No f 6STt t. tZ f' 2101 I,1Z- 1 taST, can Str' -mil Interest in property: Name and address of fee simple titleholder: 4. Contractor's name and address: 5. Surety: (Payment bond required by owner from cont Name and address: Amount of bond $ 6. Lender's name and address: tnd By ■l.n 7. Persons within the state of Florida designated by r pon whom n •ices or other documents may be served as provided by Section 713.13(1)(a)7., Florida Statutes, Name and address: t ,, 8. In addition to himself, Owners designates the following person(s) to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b), Florida Statutes. Name and address: 9. Expiration date of this Notice of Commencement: (the expiration date is 1 year from the date of recording unless a dill en date is sp-.ifie Signature of Owner -' Print Owner's Name 0 ilAS S S ?F_N g c1 f Sworn to and su cribed before me this At day of SF-pt Notary Public Print Notary's Name My commission expires: Prepared by V\&.4 . bediAl , 20 no � � JL S Address: - 3g & G.) 1 0 7 /S' I Er 123.01 -52 PAGE 4 12/05 • • ••• • • • ••• •• •• • • • •• •• • • • • • • • • • • • • • ••• • • • • • • • • • • • • • • ••• • • • • ••• SECTION 1524 • • HIGH VELOCITY HURRICANE ZONES REQUIRED OV@NEIirS IdT1 I€A11TIQI FQR ROOFING f A1 CONSIDE1d1SS • c 1524.1 As it pertains to this section, it is the responsibility of the roofing contractor to provide the owner with the required roofing permit, and to explain to the owner the content of >thisseotion..•Te previsions of Chapter 15 of the Florida Building Code, Building govern the minimum re% iiretasnts ant; siarilardsvj the industry for roofing system installations. Additionally, the following items should a t>a'1 idsed aspen gf tIle agreement between the owner and the contractor. The owner's initial in the adjacent bbx ii1ditates that The item has been explained. ' "1. Aesthetics Workmanship: The workmanship provisions of Chapter 15 (High Velocity Hurricane Zone) are for the purpose of providing that the roofing system meets the wind resistance and water intrusion performance standards. Aesthetics (appearance) issues are not a consideration with respect to workmanship provisions. Aesthetic issues such as color or architectural appearance, that are not part of a zoning code, should be addressed as part of the agreement between the owner and the contractor. Z Renailing Wood Decks: When replacing roofing, the existing wood roof deck may have to be renailed in accordance with the current provisions of Chapter 16 (High Velocity Hurricane Zones) of the Florida Building Code. (The roof deck is usually concealed prior to removing the existing roof system). _3. Common Roofs: Common roofs are those which have no visible delineation between neighboring uni (Le; townhouses, condominiums, etc.). In buildings with common roofs, the roofing contractor and/or owner should notify the occupants of adjacent units of roofing work to be performed. 4. Exposed Ceilings: Exposed, open beam ceilings are where the underside of the roof decking can be viewed from below. The owner may wish to maintain the architectural appearance, therefore, roofing nail penetrations of the underside of the decking may not be acceptable. The Florida Building Code provides the option) of maintaining this appearance. " Ponding Water. The current roof system and/or deck of the building may not drain well and may cause water to pond (accumulate) in low -lying areas of the roof. Ponding can be an indication of structural distress and may require the review of a professional structural engineer. Ponding may shorten the life expectan and performance of the new roofing system. Ponding conditions may not be evident until the original ropfin sy tem is removed. Ponding conditions should be corrected. Overflow scuppers (wall outlets): It is required that rainwater flow off so that the roof is not ov oaded from a build up of water. Perimeter /edge walls or other roof extensions may block this discharge if overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in accordance with the Florida Building Code, Plumbing. T. Ventilation: Most roof structures should have some ability to vent natural airflow through the interior of th O- structural assembly (the building itself). The existing amount of attic ventilation shall not be reduced. It may be neficial to consider additional venting which can result in extending the service life of the roof. Owne?sent's Signature �, Date : Contractor's Signature '- Il, ,dC Property Address Permit Number Rev.-1/20/2005,Computer Services, Building Department 1 • • ••• • • • ••• •• •• • • • • •• •• • • • • • • • • • • • • • • • • • • • 1 • l• High Velocity Hurricane Zone Uniform Roofing V®rfinit•Applicatfo'n Form MIAMI -DADE COUNTY BUILDING DEPARTMENT ELECTRONIC APPLICATION • • • • • •• • • • • • • • • • • • Section A (GeneralinloPiir'ation) • • • • • • • Master Permit No. Process . • • • • • • • • • • • • oc, Zie(h/ Contractor's Name: D -ce/ I L c,k'/,,C. /jai Job 4ddfe$s: • • • V. • ' •' • • • • • :d4E: •• •• • • • • • • • • • ••• • • • • • •• • • • • • • • ••• • • • • • ••• • • • IilgtbVELOCITY HURRICANE ZONES • • • • ••• Section C Mow ••. •li • • Facer Spacing far Mchod 3 st Sheet .• •.. •• • FM in Speethc Roof Components and ldendyIllam (If acomponent is not oaied6" ac'N System hisnadhateer. (it-4 NON Na: e - os oIa0 t)esignwidP�s FrauRAS't2Sor CalculaNtner Petal: 5 Plea ,S77' 3 Pa w& / �' - Board Ala Design Presage. Forgfr Speak NON Steam 11•3 • • •• •• Coen _ -oclst�p,BRew�s @ cc Ihnober Desk Typc ��i P L ak, " �7 GaugefilicknesE AnchonSaseSheet&No.of P i rr 1 C 11 Y J Ar,17177 ICS7ellfrirrn Insdat+ao Base Loper_ Base bantafon Sae and Mesta Bane iu4nsmn Fast in Obtain- t Topic Tap Sion and thiktneer Top Fos lleaieniat Feld Petineler Conner Illustrate Comments Noted and Details as ilppStafiec Wier. Edge T Shipping, Ftedies Came arras Clem; Cant Base Crawler- OWES Sc. 1 wan R Heigh. !WWI Height Height at Base Canopanen Maleda Noland lividness. Fastener 1 pe. Fastener Spading ar Sabres s Odes lhat Campy ssda RAS 111 and Chaplet 16. PhA der' �' °S ,I, : �a Top Fly: h't.r ai r=i r� D d 76% Top Pry Fasfened8mda+s FT_ IEleioint Mean Reef Height MIA IDADE BUILDING CODE COMPLIANCE OFFICE (BCCO) PRODUCT CONTROL DIVLSION NOTICE OF ACCEPTANCE (NOA) GAF Material Corporation • 1361 Alps Road Wayne, NJ 07470 • • • • • • • • • • • •• • •• MIAMI-DADE COUNTY, FLORIDA • • METRO? -DARE FLAGLER BUILDING .140 • vasT FAIL STREET, SUITE 1603 • ••• •• • •VIAIVIFLORIDA 331304563 (305) 375 -2901 FAX (305) 375-2908 •• • • • •• ••• •• • • • • • • • •• • • • • • ••• •• SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by the BCCO and accepted by the Building Code and Product Review Committee to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami Dade County Product Control Division (In Miami. Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right to revoke this acceptance, if it is determined by Miami Dade County Product Control Division that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: GAF Rnlcmid® Modified Bitumen Roof System for Wood Irks. LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement; "Miami Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA #02- 0408.10 and consists of pages 1 through 31. The submitted documentation was reviewed by Frank Zuloaga, RBC. NOA No: 03-0501.02 Expiration Date. 1106108 Approval Date:10/23/03 Page 1 of 32 Membrane Type: Deck Type 1: Deck Description: System Type E (1): APP /SBS Heat Weld Wood, Non - insulated • • • • • .. • • • • • • • • • • • • • • •. • •. •••• • 1 • • • • • • • • •• ••• •• • • 19/32" or greater plywood or wood plank decks •• • • • •• ••• •• Base sheet mechanically fastened • . • • .• • ••••••. • All General and System Limitations shall apply. • • Base shat: Fastening Options: Ply Shat: GAFGLAS #80 Ultima'M Base Sheet, STRATAVENT n. Eliminator Perforated Nailable, RUBEROID Modified Base Sheet, RUBEROID MOP Smooth, RUBEROID® 20, RUBEROID SBS Heat We1dTm Smooth or RUBEROID SBS Heat Weld 25 base sheet mechanically fastened to deck as described below; GAFGLAS® Ply 4®, GAFGLAS Flex P1yT"' 6, GAFGLAS #75 Base Sheet or any of above Base sheets attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" o.c. at the lap staggered and in two rows 12" o.c. in the field. (Maximum Design Pressure —45 psf, See General Limitation #7) GAFGLAS® Ply 4 , GAFGLAS Flex P1yTM 6, GAFGLAS #75 Base Sheet or any of above Base sheets attached to deck with Drill Tec (GAFTTTE) #12 or #14 Screws and 3" Plates, 12" o.c. in 3 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 12" o.c. in the field of the sheet. (Maximum Design Pressure -45 ps , See General limitation #7) GAFGLAS Flex PlyTM 6, GAFGLAS #75 Base Sheet or any of above Base sheets attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" o.c. at the 4" lap staggered and in two rows 9" o.c. in the field. (Maximum Design Pressure 52.5 psf, See General Limitation #7) GAFGLAS #75 Base Sheet or any of above Base sheets attached to deck with Drill-Tec (GAFTITE) #12 or #14 Screws and 3" Plates, 12" o.c. in 4 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 9" o.c. in the field of the sheet. (Maximum Design Pressure —60 psf, See General Limitation #7) Any of above Base sheets attached to deck approved annular ring shank nails and 3" inverted Drill-Tec (GAFTITE) insulation plates at a fastener spacing of 9" o.c. at the 4" lap staggered in two rows 9" in the field. (Maximum Design Pressure —60 psf, See General Limitation #7) GAFGLAS #75 Base Sheet or any of above Base sheets attached to deck with Drill-Tec (GAFTTTE) #12 or #14 Screws and 3" Plates, 8" o.c. in 4 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 9" o.c. in the field of the sheet. (Maximum Design Pressure —75 psf See General Limitation #7) (Optional except over RUBEROID Modified Base Sheet, RUBEROID MOP Smooth, RUBEROID® 20, RUBEROID SBS Heat We1dTM Smooth or RUBEROID SBS Heat Weld) One or more plies GAFGLAS PLY 4®, GAFGLAS® PLY 6® Ply or GAFGLAS Flex Ply 6 sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbsJsq. or Ruberoid Torch Smooth torch applied according to manufacturer's application instructions. NOA No: 03-0501.02 Expiration Date: 11/06/08 Approval Date:10/23/03 Page 28 of 32 Membrane: One ply of Ruberoid® Torch Smooth, Ruberoid® Torch Granule, Ruberoid® Torch Plus Granule or Ruberoi4j®•Tgftt FR.toickaRpliett avoiding to manufacturer's application instl2i ictiofts.•• • • • • • i • i i i • • Or • • • • • • • • • • •• ••• •• • • One or more plies of RUBEROID® SBS Heat WeIdTM PLUS, RUBEROID® SBS Heat We1dTM PLUS FR, RUB tQIII® lBSJjeat; eldT;1170 FR, RUBEROID® SBS Heat We1dTM; RUBMIE S Heat- We1dTM Smooth, RUBEROID® UltraCladTM SBS anc>:RWEiUtLJ SgS Heat- �Ve1dTM 25 applied .. ... . .. ..... according to manufacturer's application instructions. Surfacing: (Optional) Install one of the following: 1. Gravel or slag applied at 400 lb./sq. and 300 Ibisq. respectively in a flood coat of approved asphalt at 60 lb./sq. 2. GAF Premium Fibered Aluminum Roof Coating, at 1.5 gal. /sq. or GAF WeatherCoat' Emulsion at 3 gal./sq. (Torch Smooth applications only) 3. GAF Weathercote® MB +(Matrix 715 MB Coating), Applied at 1 to 13 4. Top Coat® Surface Seal SB(Matrix 602 SB Coating), Applied at 1 to 1.5 g Usci. Maximum Design Pressure: See Fastening Above NOA No: 03-050L02 Expiration Date: 11/06/08 Approval Date:10/23/03 Page 29 of 32 WOOD DECK SYSTEM LIMJTATIONS: .. 1 A slip sheet is required with Ply 4 and Flex Ply 71"' b 3+h1.n bsad'1s �, > haaiCa y • �yf0 �tened base or • anchor sheet. • • • • • • 2. Minimum y" Dens Deck or � Type X gypsum board is °acceptable to be installed directly over the wood deck GENERAL LIMITATIONS: •• • • • •• ••• •• • • • • • • • .. • • • • • • • •• .. • .. ..... 1. Fire classification is not part of this acceptance, refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2, Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs.sq., or mechanically attached using the fastening pattern of the top layer 3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size shall be 4' x 4' maximum. 4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at each sidelap and one down the center of the sheet allowing a continuous area of. ventilation. Encircling of the strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 12 lbs sq. Note: Spot attached systems shall be limited to a maxim= design pressure of -45 psf. 5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F) value of 275 lbf., as tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field - tested, are below 275 lbf. insulation attachment shall not be acceptable. 6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum fastener resistance value in conjunction with the maximum design valve listed within a specific system. Should the fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing, prepared, signed and sealed by a Florida Registered Engineer, Architect, or Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117. 7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 117. (When this limitation is specifically referred within this NOA, General Limitation #9 will not be applicable,) 8. All attachment and sizing of perimeter milers, metal profile, and/or flashing termination designs shall conform with Roofing Application Standard RAS 111 and applicable wind load requirements. 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field, perimeters, and corners). Neither rational analysis, nor extrapolation cha11 be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners and comers). (When this limftatdon is specifically referred within this NOA, General Limitation #7 will not be applicable.) 10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9B -72 of the Florida Administrative Code. END OF THIS ACCEPTANCE NOA No: 03-050L02 Expiration Date: 11/06/08 Approval Date:10/23/03 Page 32 of 32 - • .▪ - -. ▪ • • _. - -. -. • • - -. -. - • . • • • • • • .. • • ••• .. June 20, 2002 Mr lamed j-Gratla GAF Materials Cron 1361 Alps Road Wayne. WJ 07470.3689 • .. • • • • • • • • • • • • • ••• .. .. . . . E:. . . : . . . ... • :▪ :: MObelmagM Our Reference: R1306 Meat Mt. Gada: • This is in response to onr conversation on June * 2002. As-discussed, the following vio n* ayrrern uetsir Cins A cr;teria per ANSI/W.790 based on exit fare test data- Ifs questions arise on the above, please contact the met. Very truly yours. !kluging C Engineering Group 1 fire Proton Division to raft sat* onntawi to quarceta