Loading...
DS-06-183Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Inspection Date: 01/15/2008 Inspector: Grande, Claudio Owner: ALLISON, DUANE MERLE Job Address: 237 102 Street NE Miami Shores Village, FL 33138 -2426 a �A 16 Project: <NONE> Contractor: HOME OWNER Permit Type: Driveways /Sidewalks /Slabs Inspection Type: Final Work Classification: New Block: Phone Number (305)439 -1625 Parcel Number 1132060134950 Lot: Building Department Comments CONCRETE SLABS FOR EMERGENCY GENERATOR AND PROPENE TANK, SLAB FOR PROPANE TANK TO BE UNDERGROUND TO HOLD PROPONE TANK DAWN. INSTALLATION OF GENERATOR ONTO CONCRETE SLAB. Passed l /! ep Inspector Comments cc Failed Correction Needed Re- Inspection Fee ($75) No Additional Inspections can be scheduled re- inspection fee is paid . until Monday, January 14, 2008 Page 1 of 2 Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Sho -s, Florida 33138 ; Te ti.{ y t1 -71 3 1 ..E 5." 756.8972 BUILDING PERMIT APPLICATION FBC 2001 Permit Type (circle) JAN 06 s ®ss- Electrical L Permit No.4 t 53, aster Permit No. Plumbing Mechanical Roofing 3 *.-43, -1626' 36 %- 75 lea .11/ bkvh, Owner's Name (Fee Sim le Titleholder) bJfiO,U.e- At(u'o.i Owner's Address all &E.. ) O a $42e4 Phone # City Alidwz gtoaci Tenant/Lessee Name State rf; i✓ /,� Zip 33 l 3d - AZ /24 Phone # Job Address (where the work is being done) 9:b ' I Mt 10 Z `uct fY-fzeC - City Miami Shores Village County Miami -Dade Zip 3313 a(. vac Is Building Historically Designated YES NO X Contractor's Company Name Contractor's Address City s State Zip _ Qualifier Phone # State Certificate or Regis-1 tion No. ,_ Certificate of Competency No. Architect/Engineer's Nance (if applicable) Phone # $ Value of Work For this Permit .4> 1 4 cO Square Footage Of Work: `1/(1) Type of Work: ['Addition ❑Alteratio //n �/, ew ❑ Repair/Replace ❑ Demolition Describe Work: ( ot,.l cite -re �' G� &dam_ -�'^i) (�.2deC - GU & P ✓� iQitPUZ ! I YCI. d /� . '=r �L 1' 6 � �Rp��. yiL : } ,__ _ i ___ �� ✓ C. � @• V. , — � i, C. ` , IA. CS: Wl �rPf �1�tT-_ L fy -0 iL .. [r,t "v v,i., ::`�` ,',', ,i,.:;�. L. ,. �,?,,i 'fl,✓. ,, .,i , ............................Fees.............................. *., *, .... * * * * * * +. *. *, ........ Submittal Fee $ Permit Fee $ TOO CCF $ ` - 2-0 CO /CC. Notary $�- Training/Education Fee $ 0 - 40 Technology Fee $ 2- ., Scanning $ q • 00 Radon $ Zoning Bond $ Code Enforcement $ Structural Plan Review. $ Total Fee Now Due $ C 1 . I 0 (Continued on opposite side) "ter. 1•" Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC OWNER'S AFIIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged Signature 64*111<, 74 0444: Signature Owner or Agent Contractor The foregoing instrument was acknowledged before me this -3 The foregoing instrument was acknowledged before me this day of� J ,200(-4 b}, 1--1 . , " I - f11 -1-1 iy of , 20 by who is personally known to me or who has produced who is personally known to me or who has produced As identification and who did take an oath. as identification and who did take an oath. NOTA ' Y ' UBLI : NOTARY PUBLIC: Sign: ► '` s�i Sign: Print: — - -- -- -- Print: My Comm ;'. sion xpires: �`! ` My Commission Expires: * * * * ** * * * * * * * * * * * * * ** * *> ** * * * * ** *** ** * * * * *> **** *** * ** * * ** * * * * * * *** * **** ** * * ** ** * * *,r * *>r**** * ***>t * * * *** ** ****** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** ************ ** ************:*** ** * * * * * * * * * * * * * ** * * * * * * * * *** * ** APPLICATION APPROVED BY: ohc 05/13/03 Plans Examiner Engineer Zoning Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Inspection Number: INSP-14492 Inspection Date: 09/13/2006 Inspector: Devaney, Michael Owner: ALLISON, DUANE MERLE Job Address: 237 102 Street NE Miami Shores Village, FL 33138- SEP 1 5 RECD Project: <NONE> Block: Contractor: P & M ELECTRIC INC Per Number I %7, EL -06 -918 Permit Type: Electrical - Residential Inspection Type: Final Work Classification: Generator Phone Number (305)439 -1625 Parcel Number 1132060134950 Lot: Phone: 305 - 949 -6373 Building Department Comments Tuesday, September 12, 2006 Page 1 of 2 Passed Inspector Comments ,---- j j/ ' ./ /fr( C r".°('' Failed Correction Needed Re- Inspection Fee ($75) No Additional Inspections can be scheduled re- inspection fee is paid. until Tuesday, September 12, 2006 Page 1 of 2 Miami Shores Village Building Department N4GSS ,t 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 l l' ?4 c AM 1-11310(0 PERMIT APPLICATION R a 2006 BUILDING ���� Permit No. — 49, la . ster Permit No -, — / g3 FBC 2001 Tel: (305) 795.2204 Fax: (305) 756.8972 Permit Type (circle): Building Owner's Name (Fee Simple Titleholder) Owner's Address ,4 /� � City i, , G' �� , , State Tenant/Lessee Name Plu rr s ng Mechanical Roofing Phone # Zip /'. P Phone # Job Address (where the wc}rk is being done) a 3 City Miami Shoes Village County Is Building Iliistorically Designated YES Contractor's Company Na}ne 97 Contractor's Address City Qualifier 5ef 77 Miami -Dade NO State Zip Phone # Zip State Certificate or Registration No. .. 114),e:, . 73: Certificate of Competency No. Architect/Engineer's Nam 4 (if applicable) Phone # $ Value of Work For this ermit° t Square Footage Of Work: Type of Work: ❑Addition ❑Alteration ❑New ❑ Repair/Replace ❑ Demolition Describe Work: J11,1"-/A.,-&--,--2 1 -6> -,,J - -` = * * * * * * * *, * * * * * * *, * *,r * * * * * ** Fees * * *,r, * * * * * * * * * *** * * * * * * * ** *** *. Submittal Fee $ O. Permit Fee $ l/ dr/ 29'' CCF $ Notary $ Training/Education Fee $ Technology Fee $ Scanning $ Radon $ Zoning Bond $ CO /CC Code Enforcement $ Structural Plan Review. $ Total Fee Now Due $ (Continued on opposite side) Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City : State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Owner or Agent The foregoing instrument was acknowledged before me this ?"4-7' The foregoing instrument was acknowledged before me this 1 O day of , 20 ,6, by day oO- L , who impersonally known to me or who has produced who is personally known to me or who has produced As identification and who did take an oath. �D as identification , who did take an oath. Signature P Contractor NOTARY PU$L - Sign: Print: j J My Commission Expires: * * * * * * * * * * * * * * * * * * * ** * * * * * ** APPLICATION APPROVED BY Chc 05/13/03 NOTARY PUB Sign: Print: My POt. Notary Public State of Florida Scott Norman Thrasher 4.4KonmissiewS Nag*** OP OF Expires 0411612009 c * * * * * * ** * fir `t .119f�i�i l �; �• O:#' D-D 4 , i .e *:4 tic gong Cin 9 Plans Examiner Engineer Zoning Allison, Duane 237 NE 182 Street Miami Shores, FL. 33138 2 "c. w /(3) 4/0 Thhn 2 "c. w/ (3} NO no-a- Meter 2 "c. wi(3) 2/O ------ 2"c. w/(3) d1O 2"pvnc w"- (3 3's to 30K generator Grr&thod ELECTRICAL CONTRACTORS 1936 N.E. 148th Street North Miami, Florida 33181 (305) 949 -6373 Dade CC#16353 Broward CC #86 -CME- 1046 -X IT Duane Allison 237 NE 102nd Street Miami Shores, FL. Load Calculation General lighting: 4400 sq. ft. X (3) = 13200 (2) appl. @ 1500 = 3000 (1) laundry @ 1500 = 1500 17,700( Gen. Lighting sub -total ) Adjustments: 1 3 0 0 0 @ 1 0 0 % = 3000 remaining (14, 700) @ 35% = 5,145 General .a _ A/C ( 00 %= A/C (h`; @ 100 % = Dr _ Oven,: DishW3sher = Disal = Pool p = ELECTRICAL CONTRACTORS 1936 N.E. 148th Street North Miami, Florida 33181 (305) 949 -6373 Dade CC#16353 Broward CC#86 -CME- 1046 -X 8,145 (Gen. Lighting total ) 11 00 5000 8000 4500 1100 1-100 1200 44,045/ 240 = 183.52amps This calculation prepared and' submitted 13y: Scott Thrasher for P & M Electric, inc. 2. S . ecifications MODEL Engine Orvan Modified Ford in-line 6 Generator Rating 3- Phase, 60Hz (kVA ® 0.8 PF) 3- Phase, 50 Hz (kVA @0.8PF) Electrical System Starting Voltage Battery Changing Current Cooling Sim Coolant Capacity with Standard Radiator Lubricating System Oil Capactty with Filter Fuel or a combination of two fuels Tune -up Specs Spark Plug Gap Battery Required Battery Voltage SAE Number ,\k\v-T0,-( -\• Aot-oM EM lEll 35 kW (44 kVA) 30 kW (38 kVA) 12V 65 amp 5gal (19 L) 7 qt (7L) Gasoline Propane Natural Gas .042 to .046 (1.05 to 1.15 mm) 12 VDC 60 45 kW (56 kVA) 37 kW (46 kVA) 12V 65 amp 5gal (19 L) 7 qt (7 L) Gasoline Propane Natural Gas .042 to .046 (1.05 to 1.15 mm) 12 VDC 60 ItMCIEWICI APR 1 02006 II BY: —.11.4-9/ 41$0413 3. Operation GENERAL This section covers prestart checks, starting and stopping and eratorshou d read through this s entire rsection before set. Each op- attempting to start the set. It is essential that the op- erator be completely familiar with the set for safe operation. PRESTART CHECKS Before starting, be sure the following checks have been made and the unit is ready for operation. Refer to the Maintenance section for the recommended procedures. Lubrication Check the engine oil level. Keep the oil level as close as possible to the dipstick high mark without overfilling. Coolant Check the engine coolant level. The coolant should be about two inches (50 mm) below the radlator cap opening. Do not check while the engine is hot. Contact with hot coolant can result in severe burns. Do not bleed hot; pressurized coolant from a closed cooling system. Fuel Make sure the fuel tanks have sufficient fuel and that fuel system is primed. CONTROL PANEL The following describes the function and operation of the standard Detector 7 and optional Detector 12 generator set control. All instruments and control switches are located on the face of the control panel as Illustrated in Figures 3-1 through 3-3. The control panel is separated into a DC panel for monitoring the engine and an AC panel for monitoring the gen- erator. EXHAUST GAS 13 DEADLY! Exhaust gases contain carbonmonoxlde, an odorless and colorless gas. Carbon monoxide Is poisonous and can cause unconsciousness and death. Symptoms of carbon monoxide poisoning can Include: • mss • Nausea • Headache • Werkness and Sleepiness Temples • • Muscular Tw • vomiting • Inability to Think Coherently IF YOU OR ANYONE ELSE EXPERIENCE ANY OF THESE SYMPTOMS, GET OUT INTO THE FRESH AIR IMMEDIATELY. H symptoms persist, soak meecwl Men- tion. Shut down the un t and do not operate until it has been inspected and Probation against carbon monoxide lnhatatlon Include proper installation and regular, frequent visual and audible Inspections of the complete exhaust system. 1 -P/EM FIGURE 3-1. DC CONTROL PANEL. (DETECTOR 12 SHOWN) DC Panel Panel Lamp: Illuminates control panel. 011 Pressure Gauge: Indicates pressure of Lubri- cating oil in engine (wired to a sensor located on the engine). Coolant Temperature Gauge: indicates tempera- ture of c lrculatinng coolant in engine (wired to a sen- sor located on engine). DC Voltmeter: Indicates the battery charging sys- tem voltage. Run/Stop/Remote Switch: Starts and stops the set Dally, or from a remote location wired to the control engine monitor board. 3-2 Running Time Meter. Registers the total number of hours the unit has run. Use it to keep a record of periodic servicing. Time is cumulative; meter can- not be rat. Reset,tamp Test/Panel Lamp Switch: Resets the fault circuit only when the Run/Stop/Remote switch is in the Stop (Reset) position. Tests fault lamps and turns on the control panel lamp. Tachometer (Optional): Provides constant moni- toring of engine rlmin. 011 Temperature Gauge (Optlonal): indicates temperature of lubricating oil in engine (wired to a sensor located on the engine). Emergency Stop Button (Optional ): Push -in switch for emergency shutdown of the engine. To reset, pull switch out and move Run/Stop/Remote switch to Stop position. Then push test switch to Re- set/Lamp Test position. if s It Detector 7 Indicator Lamps: The standard control panel has seven indicator lamps which are de- scribed as follows: • RUN (green) lamp comes on when starter cir- cuit opens after set starting. • PRE LO OIL PRES (yellow) indicates engine oil pressure is marginally low. • PRE HI ENG TEMP (yellow) indicates engine temperature is marginally high. • LO OIL PRES (red) indicates engine has shut down because of critically low oil pressure. • HI ENG TEMP (red) indicates engine has shut down because of critically high engine tem- perature. • OVERSPEED (red) indicates engine has shut down because of excessive speed. • OVERCRANK (red) indicates engine has failed to start during the cranking period. Detector 12 Indicator Lamps: The optional twelve Tamp control includes all the features of the seven lamp control plus the following: • FAULT 1 (red) lamp indicates an undedicated fault. May be field programmed as a shutdown or non - shutdown, and as a timed or non -timed fault. (Normally set for timed shutdown). • FAULT 2 (red) lamp indicates same features as Fault 1 (normally set for non -timed shutdown). • LOW ENG TEMP (yellow) lamp lights if engine temperature is marginally low for starting. It may indicate an inoperative coolant heater. • LO FUEL (yellow) indicates fuel supply is mar- ginally low. • SWITCH OFF (flashing red) indicates genera- tor set is not in automatic start mode. 3 -3 FIGURE 3-2. INDICATOR LAMPS AC VOLTMETER AC AMMETER FREQUENCY/ RPM METER WATTMETER UPPER AND LOWER SCALE INDICATOR 539-0741c3 VOLTAGE ADJUST EXCITATION FIELD BREAKER PHASE SELECTOR SWITCH OTHER OPTIONAL METERS FIGURE 3 -3. AC CONTROL PANEL AC Panel AC Voltmeter (Optional): Dual range instrument indicating AC voltage. Measurement range in use shown on indicator Tamp. AC Ammeter (Optional): Dual range instrument indicates AC generator line current. Wattmeter(Optional): Continuously gives reading of the generator output in kilowatts. Power Factor Meter (Optional): Indicates percent power factor of AC output. Frequency/RPM Meter (Optional): Indicates gen- erator output frequency in hertz and engine speed in revolutions -per- minute (RPM). 3-4 Voltage Adjusting Rheostat (Optional): Provides approximately plus or minus five percent adjust- ment of the rated output voltage. Upper and Lower Scale Indicator Lamps (Op- tional): Indicates which scale to use on the AC volt- meter and ammeter. Phase Selector Switch (Optional): Selects phases of generator output to be measured by AC voltmeter and ammeter. Engine Pyrometers (Optional): Indicate engine exhaust and inlet air temperatures. Field Breaker: Provides generator exciter and regulator protection from overheating in the event of certain failure modes of generator, exciter and volt- age regulator. GENERATOR AC VOLTAGE REGULATOR The solid -state regulator controls AC output voltage from the generator at a predetermined level regard- less of load. Voltage regulation is plus or minus two percent from no load to full Toad. Random voltage variation is plus or minus one percent for constant loads. ENGINE CONTROL MODULE Electronic and relay components of the engine monitoring circuit are on a circuit board assembly. Sensor inputs are connected by the wiring harness to plug connectors on the board. The control mod- ule provides the following functions of unit protec- tion. • Overcrank - Limits engine cranking to 75 sec- onds. If engine fails to start,.the module lights a fault lamp and opens the cranking circuit. The cycle cranking option allows three 15- second cranking cycles with two 15- second rest peri- ods on the 12 -lamp control. • Overspeed - Shuts down the engine immedi- ately if overspeed occurs and lights a fault lamp. The sensor switch is mounted in the end bell on the generator shaft. It is factory ad- justed to shut down 60 hertz units at 2100 ±90 r /min, 50 hertz units at 1850 ±50 r /min. • Low Oil Pressure - Shuts down the engine im- mediately if oil pressure drops below 14 psi (97 kPA) and lights a fault lamp. The fault is time - delayed about 10 seconds following starter dis- connect and inhibited during cranking. The de- lay allows oil pressure to rise to normal before the electronic control module monitors this sys- tem. 3 -5 A pre -low oil pressure sensor and lamp pro- vides an alarm that oil pressure is marginally low, 20 psi (138 kPA) or less. The cause should be found and corrected as soon as possible. • High Engine Temperature - shuts down the engine immediately if coolant temperature rises above 215° F (102° C) and lights a fault lamp. The fault is time - delayed about 10 sec- onds following starter disconnect and inhibited during cranking. This delay allows coolant in a hot engine time to circulate and retum the water jacket to normal before the electronic control module monitors this system. A pre -high engine temperature sensor and Tamp provides an alarm that engine tempera- ture is marginally high, 205° F (97° C). The cause should be found and corrected as soon as possible. /'TAI The high engine temperature shutdown system will not operate if the coolant level is too low. The high engine temperature sensor monitors coolant tem- perature. Loss of coolant will prevent sen- sor operation and allow the engine to over- heat causing severe damage to the engine. Therefore, maintain adequate coolant level for proper operation of the high engine tem- perature shutdown system. • Low Coolant Level (Optional) — An electronic switch that is used to detect low coolant level. This switch may be connected in parallel with the high engine temperature cutout switch to shut down the engine and light the High En- gine Temperature Tamp or in parallel with the pre -high engine temperature switch to light the Pre -High Engine Temperature Tight only. note :tart- n. era - uto- uns- -age le is ting 414 ked X15 ge. age 1% ncy for Ater 3bi- STOPPING Before Stopping Run the generator set at no Toad for three to five minutes before stopping. This allows the lubricating oil and engine coolant to carry heat away from the combustion chamber and bearings. To Stop If the set was started at the set control panel or at a remote control panel, move the Run/Stop /Remote switch or remote starting switch to the STOP posi- tion. If the set was started by an automatic transfer switch, the set will automatically stop about 15 min- utes after the normal power source returns. Emergency Stop An optional emergency stop button is located on the right side of control panel (Figure 3-1). Push button in for emergency stop. To reset, pull switch out and move Run/Stop/Remote switch to Stop position. Then push test switch to Reset/Lamp Test position. BREAK -IN Drain and replace the crankcase oil after the first 50 hours of operation on new generator sets. NO -LOAD OPERATION Periods of no Toad operation should be held to a minimum. If it is necessary to keep the engine run- ning for long periods of time when no electric output is required, best engine performance will be ob- tained by connecting a "dummy" electrical load. Such a load could consist of heater element, etc. EXERCISE PERIOD Generator sets on continuous standby must be able to go from a cold start to being fully operational in a matter of seconds. This can impose a severe bur- den on engine parts. 3 -7 Regular exercising keeps engine parts lubricated, prevents oxidation of electrical contacts and in gen- eral helps provide reliable engine starting. Exercise the generator set at least once a week for a mini- mum of 30 minutes with load so the engine reaches normal operating temperatures. Onan automatic transfer switches have as an op- tion an exerciser that can be preset to provide regu- lar exercise periods. Typically the exerciser can be set for time of start, length of run, and day of week. If it is necessary to start the set on natural gas, the choke must be adjusted to the fully open position before the set will start. Make a mark on the choke housing -to indicate the position of the choke cover index pointer. Loosen the three choke cover screws (Figure 6-2) and rotate the choke cover counter- clockwise approximately 90 degrees. Tighten the three choke cover screws and place the fuel selec- tor switch in the GAS position. The set may now be started on natural gas. HIGH/LOW OPERATING TEMPERATURES Use a coolant heater if a separate source of power is available. The optional heater available from Onan will help provide reliable starting under ad- verse weather conditions. Be sure the voltage of the separate power source is correct for the heater element rating. To avoid damage to heater, be sure the cooling system is full before applying power to the heater. POWER RATING FACTORS The generator set power rating applies to sets used in standby applications. The set will operate at the stated rating for the duration of normal utility power interruptions. The rating was established fora stan- dard radiator cooled set operating at an altitude of 300 feet (92 m) with an ambient temperature of 81 °F (27 °C). Fora rating relative to other applications, al- titudes, cooling systems, or ambient temperatures, contact your authorized distributor. STARTING The following sections cover the three systems used to start the generator set. Starting at Control Panel Move the Run - Stop - Remote switch on the DC panel to the RUN position. This will activate the en- gine control system and the starting system. The starter will begin cranking and after a few seconds the engine should start. The starter will disconnect when the engine reaches a speed of 450 to 570 RPM. If the engine does not start, the starter will disen- gage after a specified period of time and the control will indicate an overcrank fault. Generator sets with the standard overcrank control will crank continu- ously for up to 75 seconds before disengaging the starter. Generator sets with the cycle cranking op- tion will crank for 15 seconds in each cycle until 3 cycles have been completed. To clear an overcrank fault, place the Run - Stop- Remote switch in the STOP position and momentarily depress the Reset switch. Wait two minutes for the starter motor to cool and then repeat the starting procedure. If the engine does not run after a second attempt at start- ing, refer to the Troubleshooting section. Starting From Remote Location Move the Run/Stop /Remote switch on the genera- tor set DC panel to the REMOTE position. This al- 3 -6 lows the generator set to be started from a remote switch. Closing the remote switch initiates the start- ing sequence described in the previous section. Automatic Starting Place the Run/Stop /Remote switch on the genera- tor set DC panel in the REMOTE position if an auto- matic transfer switch is used. This allows the trans- fer switch to start the generator set if a power outage occurs and stop it when the power retums. Start-Up Checks Observe the oil pressure gauge after the engine is started. A normal oil pressure reading (at operating temperature) is between 35 to 60 psi (241 to 414 kPa). The following gauges should also be checked for normal readings: • DC Ammeter — Normal charging rate is 1 to 15 amperes depending on battery state of charge. • AC Voltmeter — Generator output voltage should be stable and not vary more than ±1 % of the rated value while under Toad. • Frequency Meter — Generator frequency should be stable. • Water Temperature — Run the generator set for about 10 minutes and then check the water temperature gauge. the engine should stabi- lize between 180 to 195° F (83 to 91° C). TABLE 1. GENERATOR SPECIFICATION BREAKDOWN kW Model Frequency Section 1 Spec A Thru Section 2 Begin Spec 25.0 EK 50 Hz E D D T -n -n cn co co = S S= 2 D D D D c_ c -n -n T G) G) G D D-n -n -n 30.0EK 60 Hz D Penn EK • E 25.0 DDA 50 Hz - 30.0 DDB 60 Hz - 30.0 DEH 60 Hz D 25.0 MDEH 50 Hz . D 30.0 MDEH 60 Hz C Penn DEH - E 37.5 EM 50 Hz E 45.0 EM 60 Hz D Penn EM S E 37.5 DEF 50 Hz H 45.0 DEF 60 Hz F Penn DEF 75.0 DYC G 37.5 DYJ 50 Hz - 45.0 DYJ 60 Hz - 40.0 DDB 50 Hz - 50.0 DDB 60 Hz - 40.0 DEG 50 Hz G 50.0 DEG 60 Hz E Penn DEG 50 Hz F 40.0 MDEG 50 Hz F 50.0 MDEG 60 Hz E 45.0 KB 50 Hz R 55.0 KB 60.Hz P Penn KB Penn DYD Q 50.0 DYA 50 Hz E 60.0 DYA 60 Hz C Penn DYA 60 Hz D 55.0 EN 60 Hz - 70.0 EN 60 Hz - 3 kW Model Frequency Section 1 Spec A Thru Section 2 Begin Spec 55.0 KB 50 Hz R S 65.0 KB 60 Hz P S Penn KB Q S 60.0 DYC 50 Hz D E 75.0 DYC 60 Hz B E 80.0 DYC 50 Hz - G 100.0 DYC 60 Hz - G Penn DYC C E 70.0 KR 50 Hz R S 85.0 KR 60 Hz P S Penn KR Q S 75.0 DYC 50 Hz D E 90.0 DYC 60 Hz B E 80.0 DYD 50 Hz C D 100.0 DYD 60 Hz A D Penn DYD B D 95.0 WA 50 Hz H J 115.0 WA 60 Hz G J 100.0 DYD 50 Hz C D 125.0 DYD 60 Hz A D Penn DYD B D 115.0 WE 50 Hz B - 140.0 WE 60 Hz B - 125.0WE 50 Hz B - 150.0WE 60 Hz B - 125.0 DYG 50 Hz C D 150.0 DYG 60 Hz A D Penn DYG B D 130.0 DFE 50 Hz - H 155.0 DFE 60 Hz - H Penn DFE - H 140.0 WB 50 Hz K L 170.0 WB 60 Hz J L 145.0 DYG 50 Hz C D 175.0 DYG 60 Hz A D Penn DYG B D 150.0 DFE 50 Hz - H 180.0 DFE 60 Hz - H Penn DFE - H UR GENERATOR VOLTAGE /CURRENT OPTIONS RATING HERTZ 1 -PHASE STANDARD 1 -PHASE SPECIAL (B125 3 -PHASE Code Code 0 O 140 0 1 9/ /if20 0 :4,0•• O 1 / /�g0 0 1 Q/ /tf90 0 1 §/ /'�00 0 1 / /'�O8 0 1 Q/ /�20 0 1220 0 11� /230 0 120 /240 O 139 /40 O /380 0 230/ /400 0 2 • 18 3 25,44,0/ O 2 2770 X80 ��O /800 kW ' kVA 50 60 25.0 31.25 x 142 136 95' 90 87 82 82 78 47 45 43 41 me). 30.0 37.50 x 156 156 104 98 90 90 52 49 45 36 37.5 46.88 x 213 204 142 135 130 123 123 118 71 68 65 62 40.0 50.0 x 227 217 152 144 139 131 131 126 78 72 69 66 45.0 56.25 x x 234 256 245 234 171 162 156 148 148 141 135 135 85 81 78 74 68 54 50.0 82.5 x x 284 272 260 190 180 173 164 164 157 150 150 95 90 87 82 75 60 55.0 68.75 x x 313 299 288 209 198 191 180 180 173 185 165 104 99 95 90 83 66 60.0 75.0 x 313 208 197 180 180 104 98 90 72 62.5 78.13 x 355 340 237 228 217 205 205 196 119 113 108 103 65.0 81.25 x 339 226 213 195 195 113 107 98 78 70.0 87.5 x x 398 380 365 266 253 243 230 230 220 210 210 133 126 121 115 105 84 75.0 93.75 x x 428 408 391 285 271 260 246 246 235 226 226 142 135 130 123 113 90 80.0 100.0 x 455 435 304 289 278 262 262 251 152 144 139 131 85.0 106.25 x 443 295 279 256 256 147 139 128 102 90.0 112,5 x 469 312 295 271 271 156 148 135 108 95.0 118.75 x 540 516 361 343 330 312 312 298 180 171 185 156 • 100.0 125.0 x x 568 543 521 380 361 347 328 328 314 301 301 190 180 173 184 150 120 115.0 143.75 x x 599 437 415 399 377 377 361 346 346 218 207 200 189 173 138 120.0 150.0 625 125.0 156.25 x x 475 451 434 410 410 392 376 376 237 226 217 205 188 150 130.0 162.50 x 494 469 451 428 426 408 247 235 228 213 140.0 175.0 x x 532 505 486 459 459 439 421 421 286 253 243 230 210 168 145.0 181.25 x 551 523 503 476 476 455 275 282 252 238 150.0 187.5 x x 570 541 520 492 492 471 451 451 285 271 260 246 226 180 155.0 193.75 x 538 508 486 486 289 254 233 186 170.0 212.5 x 590 558 511 511 295 279 256 204 175.0 218.75 x 607 574 526 526 304 287 283 210 180.0 225.25 x 625 591 542 542 313 298 271 217 0- 50 Hz only. 20 - 80 Hz only. • 0- 50- and 60 Hz 0 - Not ReconnectIble. CL Is) -1 9? -1 A 3 '-I R -A-C) • •E• v STD MONITOR YYM V �M C- 30 /C !Zi-U2. MEM MIN MEW Qd .IMIZON NEM (WIRING DIA9RAM) 612•C4 .350 ,612C4353 1 12,60 MA 10 REMOTE ANNUNCIATOR TBI3 •OVEBCRANK LOW OR. PRESS NI ENO TEMP LC ENO TEMP OVERSPEED GENENATINO REMOTE SWITCH (FRONT YIBW) WIRING DIAGRAM (REAR VIFW) (BUT V1EW) • 45 -9 (4-10 4-- u (-12 (-13 (--14 (- -16 (-16 (} -17 41-56 19 20 21 TB II1i riu aw r�aa■ W121 SEE NOTE 1i1 REMOTE 12 RUN UNITS WITH PRE-ALARM 6 SHUTDOWN PRE- w,.ARM SHUTDOWN SG g-30 SI r S7 I TO TERM 62 663 ON T821 190 -240 VAC SEE NOTE 2-1 STANDARD 6 $ S 6 • PENN STATE UNITB �y S3 SEE NOTE 5 S5 33 28 E2 CBI(DYC ONLY) 22 26 E3 ) 81 BTI — `i'1E =i NOTES L W12 USED ON STD CONTROL ONLY 2.USED ON PRE -ALARM CONTROL ONLY 3.REMOTE ALARM CIRCUIT RATED 5AMP MAX 4.SHUTDOWN a ALARMS 4.1 STD CONTROL 4.1.1 SAFETY SHUTDOWN 8 ALARMS ON OVERCRANK,OVERSPEED,HI ENG TEMP 8 LO OIL PRESS 4.1.2 SAFETY ALARM ONLY ON 1.0 ENG TEMP 4,2 PENN STATE CONTROL 4.2.1 SAFETY SHUTDOWN & ALARMS ON OVERCRANK 8 OVERSPEED 4.2,2 SAFETY ALARMS ON HI ENO TEMP,LO OH. PRESS 8 LO ENG TEMP 4.3 PRE -ALARM CONTROL 4.3.1 SAFETY PRE - ALARMS ON HI ENG TEMP 8 LO OIL PRESS SCHEMATIC DIAGRAM Ay NOTE 3 OD COMMON (� ALARM 11 REMOTEa STOP•••-o-C RUN °jj 05160 E 040 ^0812 i ,,DS13 0814 ♦0815 KI4 —9416 S3 K12 33 -71 26 26 26 0 0 0 ID 0 KII 4819K11 • K12 • SI ORS �;'0 - 582088730 1 I-4 31 • S3 ® 02`1 ;SEE NOTE 1- SEE 34E 81 NOTE 2.-PF jjjS2 -V- 0//�������� //��NI ENO 1*—V TEMP ®LTO ENG EMP 37 0/S ®GENERATING 5111 2 MI2 6 K2 K14 KI2 40 TERM 62 81 • 63 ON T821 190 -240 VAC K11 KI4 %I- 853 21 IK1322 CBI BTI -"I 4.3.2 SAFETY SHUTDOWN El ALARMS (52 25 O1 ON OVERCRANK,OVERSPEED,HI ENG B 5 TEMP 8 10 OIL PRESS 24 4.3.3 SAFETY ALARM ONLY ON 1.0 ENG TEMP 5.S3 OVERSPEED SWITCH MOUNTED IN GENERATOR END BELL 6.UNLESS OTHERWISE NOTED,ALL COMPONENTS ARE SHOWN IN THE STD CONTROL DE- ENERGIZED POSITION d PRE -ALARM B PENN STATE WPEC B/gf N 0 YJ O PENN STATEISPEG AD,E,F,G) 11111- K1 AI2 K13 0 ENGINE puts v• (REF) it 015. 'Alt ,CD. 01T DESCnmON 81 1 STARTER S SOLENOID-INOINE BTI BATTERY -121 CBI 11 3208165 E2 1930108 i93E109 I93E104 IR IT BREAKER 17 5 ANPLOTC ONLY)J SENDER -01L PRESSURE S18000 -90119 TEMP (000. 016) SENDER-9ATER TEMP (3(5. DEN, 016) FUEL GI RI 112 AL)ERNNTOR A REGULEL98 i40L_EN010 -ENG STOPPING SOLEN010- RATER 51 S2 53 STITCH -101 OIL PRESSURE SVITCN -NIGH WATER 1(50 SIITCN- OYERSPEEO 55 S8 SRI - 01 RA T RP SKITC6 -109 OIL RE55 (801- 1 TCH -HIGH VA/ R P; CONTROL 803 PART IISE All 3000501 1 0081100- EN51NE 0081001 012 3000 33 I CONTROL -STD CRANKER 3 4 0511 1 6067 1. -CYCLE CRANKS 332 -1276 1 PLUG - KEYING 322- 4. 1 LIIP -PANE1 3218149 1 HOLGER -LA1P 0512 3220107 I MP- ,VERCRAN0 0513 3220111 I 108P -00E8 PEE0 0514 3221108 1 LAMP -L01 011. PRESS 0515 3120109 1 LA1P -411 ENG TEMP 0516 3220110 1 LAMP -LO ENG TEIP 611 07B1058 1 RELAY -STA 015CONNECT 612 30181058 I RELAY - IGNITION K13 30191031 1 RELAt-START SOLENOID R11 30181061 I RELAT- STARTER PROTECTION 111 1938101 1 1 GAUGE -011. PRESSURE 552 1139100 1 I GAUGE -RATER TEIP 113 3021161 1 051TER- CHARGE 30 -0 -30 _ 711 308 -Y _ j L SNITCH -PANEL 15611? 30803 I PLATE -INSTR ON OFF SI2 308PI i aif flSEE�O -9) -04) 1811 332E7950E8i I TERMINAL BLOCK 111111 33201241 i 1 STRIP 612 332A92[1BEF) 1 TERMINAL ROCK 33201139 1 MARKER STRIP T :13 3 20699 9154. 1 T061INM. BLOCK 33201240 111 3300534 1 118195 0A011155 112 33601918 1100 ASST (STD CON? 'NLT 545E26 PARTS IST -CUNT NOR EN 30103253 BRACKET -ENG CONTROL 30143I67 PANEL -ENG CONTROL 9082110 SILK'CREEN 1 -01 -02 -03 -04) 9882510 51L11579EEN 1 -05 -06, 3001321 591166- 1. CT -0 -05 • CP 0 wow 01 E3 SII DSII 15 •WHEN USED • KII • A O•Q'E1I• STD CRANKER CYCLE CRANKE -01 - 03 D' - /9222A DDB- R/9222A O DYJ- R/9222A DDA-R50/9222A DOB- R50/9222A DYJ- R509222A f- R/9222Y MJ(8060-R/92220 DYA- R/9222C WC-R/95229 DEF- R50/9222G DEN- R50/9222E DEO- R50/9222F DYA -R 50/92 2 2D DYC -R 50/922 2 C PRING•RELAY 801 DDOWN 11162 KI VAS 3 -14 S 322073 141 -514.(4•74. T9I(1.a IL4lase 11 ADDED 1 :3A 1111 '34 LIM ADDEO ELFA. 4.11 5EMMI FfA iaO.17figr:I)G.TTST:fG),l.rNMal nA•• -Daril CIRCUIT IVI • no. ✓0 ICEMEN Wall *WM CONTROL -GEN SET ENG(12V,DIESEL) (WIRING DIAGRAM) JVZD. -02 -b4 -OS 2 WIRE REMOTE e.4 . - 04 re. STARTING ) 612C4353 • ( POSITION `— `— 16- - 2 'RECONNECTABLEI 6124173 612C3919 WIRING DIAGRAM REAR VIEW PANEL /8 DS2I CONTROL BOX (INSIDE) T21 VR21 pia,.x .___, /s, TB 21 .n11 •, i LI • wasu N ii • • ,. •K5 WI2 -NOTE � SEE VOLTAGE :: • 61 110 CHART • ea� r C921 1 2 3 4 5 8 7 8 9 1111 12 86 0-067 HOUSING - CONTROL BOX , GENERATOR F2 FIELD FI VR22 1. 2 3 4 5 6 7 8 9 �ts0 0 021 TI s T2 ■ T3 S T4 ■ T5 S T8 S T7 S T8 • T9 TIO S TII s, 712 ■ (MOUNTED IN fiEN) TI •••� 72 —� T3 —0' T4 4 _._j- T5- 76 T7. 7 T8' 8 —� T9 •TO'84 9 TIO� 10-15/ TII --% TI2 —� NOTE, CONNECT LEAD W12 FROM TERMINAL T921 -63 70 T921 -(H_) PER VOLTAGE CHART BELOW 115/230V, 50 Hz, (H6) 120/240V, 60 Hz, (H5) SCHEMATIC DIAGRAM VR 22 F T6 FIELD TII T12 Fl 621 T1 T2 T3 5 1 190 0500 91I VR 21 1111 1122 3 8 5 401 2 1 •I SCHEM 0(60 6250987 9 6 8 10 1 R21 ■x; 1206 V,� 0 T8 T9 TIO 8 T2I 9 10 1 1( R22 I 2 0521 121 :41022 0 7IT, 1121 AO. 4 VOLTAGE CONNECTIONS 3 PHASE 110 /190V, 50 Hz, (H31 115/200V, 50 Hz, (H4) 120/208 V, 60 Hz, (H3) 127/220V, 60 Hz,(H4) 139/240V, 60 Hz, (H5) L3 NOTE, UNLESS OTHERWISE NOTED, ALL COMPONENTS ARE SHOWN IN THE DE•ENERGIZED POSITION LI L2 LO L3 C921 220/380V, 50 Hz, (H3) 234/400V, 50 Hz, (H4) 240/416V, 60 Hz,(H3) 254/440V, 60 Hz, (H4) 277/480V, 60 Hz, (H5) LI L2 LO L3 7 7 901116 V51 Rt/ 5i. MIT NO. 0821 32082 320818 320P307 Ott Nx«nOH CIRCUIT BREAKER.ISAMP 25 -40KW1 CIRCUIT BREAKER.20AMP (41 -90KW) LOCK-CKTB' K AT 0521 322A131 I LIGHT-UPPER SCALE 0822 3226130 1 1 111- A121 1 ffNERATOR K21 30181061 I RELAY- VOLTAGE • L C 30183244 I BRACKET -RELAY MTG i M21 3028718. } 1 VOLTMETER- AC.0.300,0 -600 `fi'fl .303P170 + I RHEOSTAT- VOLTAGE AOJ 35K 303P32 1 TAT 1322 1350 5560REF)T 1 : RESISTOR•4.1000, I /2WATT S21 308612 1 • SWITCH - VOLTMETER 303-76 Y 1 IKNOB 616>t3Zl9 T21 3150342 —1. 1 TRANSFORMER -VOLT REF TB21.• A124: 1 MARKER- STRIP VR21 33201264 • 110AR0 ASSY -PC VOLTAGE RGLTR VR22 305D489(REF) 1 CHASJIS ASSY -V RGLTR -60KW _ '305D483(REF) 1 CHASSi9 ASSY-V RGLTR (61.90KW) WII 3380524 I WIRING HARNESS Ai C33661913. A §$r 301C7168 ) 1 PANEL•GEN CONTROL _ • 30103158 _' I CONTROL BOX 402670 4 DAMPENER _ 537 -49 T STR ND 508PI 4GROMMET- RUBBER 98C2169 1 SJkKSCREEN•CONTROLPANEL AC } 545A22 1 PARTS L1 §T AC CONT HOW 1 PHASE 115/230V, 50 Ht, (H6 120/240V, 60Hz, (H5 T9 712 LI T10 KAY I T IPENN STATE Y 41 - 90 -02 -04 LO SUPERSEDES SAME DWO NO. DATED 5.21 -70 n.:0, 1<..,Iw( INN 77 L2 •,owe w 25.90 KW- 15R/I STATIC 'I- 4 -71 r'J.W.O. (•"SP,. Mwri'� "• CONTROL- OEN SET AC (WIRING DIAGRAM) 3PH, 50/60 Hz 12 W RECONNECTABLE 6I2C3919 Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Inspection Date: 04/27/2006 Inspector: Levrack, James Owner: ALLISON, DUANE MERLE Job Address: 237 102 Street NE Miami Shores Village, FL Project: <NONE> Block: Contractor. MIAMI GAS CORP Permit Type: Plumbing - Residential Inspection Type: Final Work Classification: Gas Phone Number (305 439 -1625 Parcel Number 1132060134950 Lot: Phone: (305)634 -6646 Building Department Comments Wednesday, April 26, 2006 Page 1 of 2 tilA/106 Passed pec • 4 • m : ` nts Failed Correction Needed Re- Inspection Fee ($75) No Additional Inspections can be scheduled re- inspection fee is paid. until Wednesday, April 26, 2006 Page 1 of 2 4:zct AM alal�. Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 BUILDING Permit No. . 1001 PERMIT APPLICATION Master Permit No. P5— t— :* — I FBC 2001 Permit Type (circle): Building Electrical Plumbin Mechanical Roofing Owner's Name (Fee Simple Titleholder) /3 Cl. pi vie 4 If (So va Phone # .305 1139 / i/6.2' Owner's Address rg ? /0l ,f:-. /0;)-2- City//103/V)5 .540 5 State rLr Zip 33 ,63 Tenant/Lessee Name , -vv-e. Phone # ')0e� "75 Job Address (where the work is being done) ,Y" €- City Miami Shores Village County Miami -Dade Is Building Historically Designated YES NO X Contractor's Company Name 111441 1111 145 C© r-f Contractor's Address 32?)6 /0 (A L(1 6 City Ml +RYA• State r(- Zip 3.3/ y2 Qualifier O-/11 e / L _ 0-prf✓ 0 ,7 de-Z_ - /C8/ Zip Phone #S0 )'— (J -('c 6 Architect Engineer's Name (if applicable) Phone # $ Value of Work For this Permit 1/10 Square Footage Of Work: Type of Work: ['Addition Alteration ['New ❑ Repair/Replace [ - ❑ Demolition Describe Work: Rcvpopl_ (31 S f"-As-\0 ��� ,i2 �� Yie CA-Lo Submittal Fee $ Permit Fee $ /k0 CCF $ Notary $ Training/Education Fee $ Technology Fee $ Scanning $ Radon $ Bond $ CcAie Enforcement $ Structural Plan Review. $ Total Fee Now Due $ (Continued on opposite side) O1'x e.:-tizt ' k 4 o Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged Signatur Signature 464 Owner or Agent Contractor The foregoing jnstrument was acknowledged before me this The foregoing instrument was acknowledged before me this 6 day of <_, 20 , by `%74- `L- --Gleof , day of/42.661 , 2006 , by _'' , who is personally known to me or who has produced f 2)4 O who is personally known to me or who has produced il vizi/ 73 5/3 dentification and who did take an oath. as i • entificati, and who did take an oath. a e NOTARY PUBL C: NOTARY PUBLI /� ,, Sign: �C 'y.� C 51fi1F OF �� Print: a. C C ; (� O A Print: r �� e�nandez Commission # DD495174 My Commissi. ; - ! mmission # DD501410 Expires: JAN4Q1� sires: FEB. 10, 2010 r**** ** * **** *,t *+'�o'ttYllttat'it littt$n` g o.,'�lnnc. *,r� * ****7* *,t,t,Ht�lr�lr� * *****�4�Y,r tome '$their ovrato **** *a (Certificate of mpetency Holder) My Commission Expir r � • State Certificate or Registration No. Certificate of Competency No. ********* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** * * *. * *J * * * * * * * * * * * * * ** ******** * * * * * * *** * * * ** * * * * * * * * * * * * * * * ** APPLICATION APPROVED BY: Plans Examiner Engineer Zoning Chc 10/14/03 b7 At c> e_ 4\kt.son pit c 1-10 <Aid 1.11■11. IF,Awc-ior ..■••••■■■ --,, Cc: P-cr I 1 A 7■C; 7Y1 '474-6.6 , .1 T \ q /..k, i N 1 1 1 3235 N. W. 41 Street Miami, Florida 33142: GAS CORP (305) 634-50---r 9-44 ,e 11! bc,(.0 n6 Al\ 150 =Q(Y2ALE, top,s4 tcvJ sgvtec46.... 800tha;mt 5c'ecset(-1 Cvs1 Tio 600ce 4 '1 Q-'-;25 35' AiNcoy esru goo, oosn c(t- Wove ij6r‘A-v". 3235 N. W. 41 ati.m„ Miami, Florida 33 Ai\ir I GAS CCU (105) 634-;,, , 77) t' re ,1 CM /UVl P ) � t. i (,)bb, cam ` rtie� IF::- CP/iri O ti•. : P,47)14;41:4 Li LMti. ( M ;k 1.g}, 46( r~FiV) 3, ' l -eCA- VL WI/0' rz Pvt Avi, 1 U iL. IC 1 ` iji-wz.,4-11 ' t- aiL u1i 2 V=140i.L a°r : y : (9,44 TA-Ax *7 1 oc , ,„ t , G � !4 / mss'„ i, � Gok X41 es4a-pt",,404 Liz�. 04, / . " �f- ae,s iA (vb veitvvi cvv2c 4AA.. stArc h C 4Sp 4L .04) iotArAz 4e0 Si c r14X I Gz stt- fr4 Off`= A-vi rampalikt."— TA-4C 176 17.""C f foirtA‘Fe "ii'"Aranesw \A GouvI ' , To pc-6144t.,, (darbepoetin alfa) ZONING CRITIQUE SHEET PERMIT # D50 d JOB ADDRESS: d3 t7 J E /O /Orli Sfreef APPLICANT: APPLICATION: UGr‘P. All iSon DATE f COMMENTS /� INITIALS 1. Prcv►de ex 5idhed An4 sailed 5i /�-vel o+ )(ape( +L V I A� l,•clvc�cs prod �.ser,� Work ca„rA AiPets s✓1loto4u,r. Se+batk (etfvire.-re. 64r. L , mu A4 be 10 1. r lu..4 side_ Pr,, f evil %.',•e_ cn rm.�1 ec,r )/z y /p, P''•11 1; ,.P . Ct- W410 'd akl . --7"," I del sc� e 4&e pr.�p Uerk �� l all d'c:^4engfOIN 6 ' rn ? .04 l'Ae. 13e. $uoe * l cc�.rr x/�_ /J L • P. f 4 �P J !2P L� ` EJ�aAP��t �d r � +�(,Jr �+OI^ r. H, S. Go l l .C'� ✓r7Port' 30.92 C Lt ; .va% SKETCH OF SURVEY Lots 154 16 and 174 Block 36 ,' AN AMENDED PLAT OF MIAMI SHORES SECTION ONE, according to the Plat thereof, recorded in Plat Book 10, at Page 70, of the Public Records of Dade County, - Florida. 39.0 • /04 I HEREBY CERTIFY; That the attached "SKETCH OF SURVEY" of the above described property i.s true..yand correct to the best of my knowledge and belief 'asy.,r aently.;:lirveyed and platted under my direction. r Vice 'PreS. Robert. C. Schwebke Registered Land Surveyor -; 1O-6 State of Florida "° r n77 25 .'9,2r ". yyny Homeputer• Forms Processing System for Laser Printers 1 -(802) 773 -3018 vi0 2K 514 0 P 4•S' 8pQ Sy/L c -retie D POo4- Mr /o /5.5' 3.0' op-4" taiLa ZZ.5' 5' 0o Ga24GE 5,4 nil _ as/ 5• ere D,Qa' /-t 48.0. ?.5. BATH BED/IoosH 8EOROOf! f4 1-41L geokt DOA) 8ED2LOH o/u /,v4 Roo Al Po YE2 N Oak. K/r6NE.0 H 7.0' 7.0' 0 •8.0 ' 84TH 66-0/Z00/y Env r2-- 540' 20.5' PO.0' 0 PpK $r • • • • • • • • •• ••• • •• ••• • •••• • • • • • •• •• • • • • • • • •• • •• •• ••• • • ••• •• •• •• •• ••• • • • • • • •••li • • • •••• • • •• • • •••• • • •• ©a. in• xw 0 `4 K (D 2 to • tri r 0 rt c � rnm rt w z F-' r En 0 •••• • • • • •• • •• R •• • •' ••s•• • • 0 {••1•• '•• ••••• ; • La' Homeputer. Forms Processing System for Laser Printers 1 -(802) 773-3018 4i 5 (1=- (4 • N/02K SHOP 0 3.0' 8BQ sz2eevf0 Poo[ • PArio /5.3' 48.°' 8srA/ BATH BED/ZOGK BEDROOK goon NOOK o /u/w4 K /TG yE/�J A2oon RoOH BED/24° f1 Pa YEit 1 70' 7.0' 84 rH $E0/zO0h1 E/v r2-- 51°' 1 Za•5' 0 J ti, ;,:11j v v.; Jd� `` • • • I• • • • •••• • •••• •• ••• • • • • • • • • • •• • •• 1 •. •• ••• • • • • • •• •• •• 1 •• •• •• • • • • • • •••I • • • •••4 • • • • • •••l • • •• c(Dw P �• N 11 a (AN - o O ti Z v• ai AI tij K O p+ N C1 pi al (D H - 1--, Fes• N 0 z • • o • j.. • , 0,1 • • ...�.. • • • ••'11•• • . t • N iv • ■ • i •1•- • ,Q • • • L.) • • •.• • 'PL4N:.:pr'SLRVEY SCALE I -r • • • • • • • • • • • ••, • • • ••• • • • • •• ,•• •• • •• : • • • :• • • • ••• • •• •l. • • • i Total Due: $0.00 I Invoice Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL 33138 -0000 Phone: (305)795 -2204 Fax: (305)756 -8972 BiII To DUANE MERLE ALLISON 237 102 Street NE MIAMI SHORES, FL 33138 -2426 Return to: Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL 33138 -0000 Invoice Number: DS -1 -08 -30750 Invoice Date: January 14, 2008 Permit Number: DS -1 -06 -183 Date Fee Name 01/14/2008 Expired Permit Renewal Fee Payments Fee Type Calculated Fee Amount $75.00 Total Fees Due: $75.00 Date Pay Type Check Number Amount Paid Change 01/14/2008 Check 462 $75.00 $0.00 14 PAID Total Paid: $75.00 Monday, January 14, 2008 Miami Shores Village Building Department 10050 NE 2 Ave, Miami Shores, Fl 33138 Tel: (305)795 -2204 • Fax; (305)756 -8972 1/8/2008 To: Current Owner 237 NE 102 Street Miami Shores Village, FL 33138 -2426 Permit: DS -1- 06-183 Address:237 NE 102 Street Miami Shores Village FL33138-2426 Date Expired: January 23, 2007 Type: Slab for Generator Dear Sir or Madam In order for us to serve you better, we need to keep our files up to date. Our records indicate that the above reference Permit has expired. The Building Department has determined that the work applied for has been completed with out the required inspections and it has been more than 180 days since your last approved inspection and thus your permit has expired as per Sec. 104.5.of the Florida Building Code. You are required to renew your permit and schedule all required inspections. In the event you do not comply with the requirements herein, the Building Department will file a complaint with Miami -Dade County Building Code Compliance Office for possible disciplinary action against your licensed contractor And/or if permit was obtained by the home owner the requirements of the Unsafe Structure Code of Miami Dade County Sec. 8 -5. (3) will apply. "The building shall be presumed and deemed unsafe and a permit shall be obtained to demolish the structure or bring the building in to compliance with applicable codes as provided herein." Please contact the Building Department, immediately upon receipt of this letter. Sincerel C16fudio Grande C.B.O Building Official/ Director/