CC-09-569Inspection Worksheet
Miami Shores Village
10050 N.E. 2nd Avenue Miami Shores, FL
Phone: (305)795 -2204 Fax: (305)756 -8972
Inspection Number: INSP - 110814
Permit Number: CC -4-09 -569
Scheduled Inspection Date: November 13, 2009
Inspector: Bruhn, Norman
Owner:
Job Address: 210 NE 102 Street
Miami Shores, FL 33138 -2427
Project: <NONE>
Contractor: IVY H SMITH COMPANY
Permit Type: Commercial Construction
Inspection Type: Final Building
Work Classification: New
Phone Number
Parcel Number 1132060480010
Phone: (305)257 -0222
Building Department Comments
AT &T IS PLACING A NEW CABINET FOR FUTURE
SERVICE SEE ATTACHED SKETCH FOR DETAILS
a_41011,09
Passede// ,
Failed
Correction
Needed
Re- Inspection
Fee
No Additional Inspections can be scheduled until
re- inspection fee is paid.
Inspector Comments
No Ureka Palms.
Spoke with Sharon Office Manager at Ivy. NB
November 12, 2009
For Inspections please call: (305)762 -4949
Page 1 of 20
Miami Shores Village
Building Department
10050 N.E.2nd Avenue, Miami Shores, Florida 33138
Tel: (305) 795.2204 Fax: (305) 756.8972
BUILDING REC(0`'E Permit No. (fM .9- -(0-9,-
PERMIT APPLICATION AP ®7 009 ter Permit No.
FBC 2004 ' .141...
Permit Type (circlet : 7Building ) Roofing
Owners Name (Fee Simple Titleholder) / T ) C t C 0,7) Phone #
Owner's Address L i 1 u ;'a ' -? L`q T
City j') ) i fir?.)
State C--
Zip
Tenant/Lessee Name Phone #
Job Address (where the work is being done) -°? /C. ? C
City Miami Shores Village County Miami -Dade Zip
FOLIO / PARCEL #
Is Building Historically, Designated YES NO
Contractor's Company Name II,/ I"1 .
Phone #
Contractor's Address I t C( 5 't : S 1
City f--)i r Y state FL Zip
"ITT
Qualifier Name
State Certificate or Regi$tration No.
Architect/Engineer's Name (if applicable) 6_21 I f h i P Fib 1 Phone #
Value of Work For this Permit $ ' L C L'
Phone #
Certificate of Competency No.
Type of Work: E A 1dition
Describe Work:
c r �,
Square / Linear Footage Of Work:
['Alteration ❑New
❑ Repair/Replace
A, FLA:: I -
•b
❑ Demolition
i� TIC
Submittal Fee $ Permit Fee $ VIN F=; CCF $C
Notary $ Training/Education Fee $ Technology Fee $
Scanning $ Radon $ DPBR $ Zoning $
Bond $ Code Enforcement $ Double Fee $
Structural Review. $ Total Fee Now Due $
See Reverse side -,
Bonding Company's Name (if applicable)
Bonding Company's Address
City State Zip
Mortgage Lender's Name (if applicable)
Mortgage Lender's Address
City State Zip
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has
commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating
construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS,
WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC
OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all
applicable laws regulating construction and zoning.
"WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR
PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING,
CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF
COMMENCEMENT."
Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must
promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person
whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site
for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the
inspection will not be approved and a reinspection fee will be charged.
Signature
Owner or Agent
The foregoing instrument was acknowledged before me this
day of , 20 _, by
who is personally known to me or who has produced
As identification and who did take an oath.
NOTARY PUBLIC:
Sign:
Print
My Commission Expires:
APPLICATION APPROVED BY:
Signature r '; +_
Contractor
The foregoing instrument was acknowledged before me thisk 1-I4'
day of & , 20 0 y 177
whc is personally known to mesr'who has produced
as identification and who did take an oath.
NOTARYPUBLIC:
Sign:
Print:
My,
ommission Expires:
Plans Examiner
Engineer
Zoning
(Revised 07/10/07)
1/
Inspection Worksheet
Miami Shores Village
10050 N.E. 2nd Avenue Miami Shores, FL
Phone: (305)795 -2204 Fax: (305)756 -8972
Inspection Number: INSP - 110823
Permit Number: ELC -4 -09 -570
Scheduled Inspection Date: August 04, 2009
Inspector: Devaney, Michael
Owner:
Job Address: 210 NE 102 Street
Miami Shores, FL 33138 -2427
Project: <NONE>
Contractor: MESA ELECTRIC SYSTEMS CORP
Permit Type: Electrical - Commercial
Inspection Type: Final
Work Classification: New
Phone Number
Parcel Number 1132060480010
Phone: 305 - 279 -5498
Building Department Comments
ELECTRICAL WORK FOR NEW AT &T CABINET
Inspector Comments
Passed
Failed
Correction
Needed
Re- Inspection
Fee
No Additional Inspections can be scheduled until
re- inspection fee is paid.
niunnef nz 9nna
For Inspections please call: (305)762 -4949
Dann 1 of �F
Miami Shores Village
Building Department
10050 N.E.2nd Avenue, Miami Shores, Florida 33138
Tel: (305) 795.2204 Fax: (305) 756.8972
BUILDING
PERMIT APPLICATIO
FBC 2004
Permit Type: Electrical
Owner's Name (Fee Simple Titleholder) RC U Phone #
Owner's Address .10 P.) E. i 0 2 s r
City inj f ')I S`AORe5 State Pu Zip 3?)I ? g
Tenant/Lessee Name Phone #
Permit No. ELC
Master Permit Noll(' O 1, - "5
E -MAIL:
Job Address (where th work is being done) a1O Ne ) 0 z S T
City Miami hores Village County Miami -Dade Zip 3313
FOLIO / PARCEL #
Is Building Ristoricall3
Designated YES
NO
Contractor's Company Name In est eLE C.'TRt l'_ 5kiSTr-./>7S co Phone #
Contractor's Address 1 [2_9 ® 5 l t1 yg S
7 �6 1S;- 6061+
City fT) I P /Y) % State J l - L. Zip 3316c–
Qualifier Name ' 1 CAS �f atC SA''' Phone # .Z- 3�
3 cis - ��2 3-)
State Certificate or Registration No. Ea '3601510
E -MAIL:
Architect/Engineer's Name (if applicable)
Certificate of Competency No.
Value of Work For thi$ Permit $ 1 0 00
Phone #
Square/ Linear Footage Of Work:
.r,
r='ll'ype of Work: DAddition JJAlteration New 111 Repair /Replace. ❑ Demolition
$scribe Work: (T - T I S PLO- c i,i c, .P ' N r LO Ci) 8; /)ET I C
FcI -Pr- s6 -kViC P set ATJ D si< TC il R LZE ricv i s
E`t
15 is irxxxxx xxxxxiexxxxx xxxxxx xxxx xxxxxxxxx Fees' *". xx**** xxxxxxx*xxx**wwxxxxa:*ac***wxxxxxxxxx
ub�ihitrafFee $ V Permit Fee $ /. -eo,e, ® CCF $ CO /CC
;Notary $ Training /Education Fee $ Technology Fee $
r,
Scanning $ Radon $ DPBR $ Zoning $
Bond $ Code Enforcement $ Double Fee $
z Structural Review. $ ;! Total Fee Now Due $
See Reverse side -->
Bonding Company's Name (if applicable)
Bonding Company's Address
City State Zip
Mortgage Lender's Name (if applicable)
Mortgage Lender's Address
City State Zip
Application is hereby made to obtain a permit to do the work and installations as indicated. 1 certify that no work or installation has
commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating
construction in this jurisdiction. 1 understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS,
WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC
OWNER'S AFFIDAVIT: 1 certify that all the foregoing information is accurate and that all work will be done in compliance with all
applicable laws regulating construction and zoning.
"WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR
PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING,
CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF
COMMENCEMENT."
Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must
promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person
whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site
for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the
inspection will not be approved and a reinspection fee will be charged
Signature
p•A 712
Owner or Agent
The foregoing instrument was acknowledged before me this
day of
who is p
who has produced
Signature
The foregoing instrument was acknowledged before me this
day of
/4'
,206 by
ho is personally known to
who has produced
6 DI
identification and who did take an oath. as identification and who did take an oath.
NOT ',; UBLIC:
Sign:
Print:
My ommis
xxxxxxxxxxxxxxxxxxxxxx xaexxx4exxx xxxxxxx
APPLICATION APPROVED BY•.
(Revised 02/08/06)
NOTAR UBLIC:
AEI
Sign:
Print:
My
•
• r• �r
Ars
EPIRE:May3,
T ni P
D 417418
ommission
Expires:
cx xxx xxxx xX Xx x x xx xxx xx xxx xxxx xxx x WW WWxx Y.x
Plans Examiner
Engineer
Zoning
w
0
z
N
w
z
VTLLAG OF MIA_V_I SFORFIS
'ERMIT SKTCH
R/W
5' SIDEWALK
NE 102ND ST
N
EOP
GRASS AREA
w
\L•
C /L--- - - - - --
EOP
GRASS AREA
0
N
"PODOCARPUS° PLANTS TO BE
PLACED AROUND THE CABINET PER
CITY OF MIAMI SHORES REQUIREMENTS
RECEIVED
APR % 8 ; '009
-�nres Village
CT To - =y I-I+ALLFEDERAL
STATE AND Cr •
' FiL GULATIONS
/
C)L0(7-5„c9
DRIVEWAY
5' SIDEWALK AT &TTHHG
CONSTRUCTION NOTE
SURVEY SITE AND SET PAD
ELEVATION FOR A MINIMUM
OF 100 YEARS FLOOD.
130'
NOTE:
AT &T WILL CUT & RESTORE
CONCRETE SI DEWALK AND
GRASS AREA.
L
1
PROPOSED
ALP -248 CABINET
4•2'WX2'213X4'H
PROPOSED �n
FPL HANOHOLE —
0
w
Q
EXI STI NG AT &T XBOX
TO BE UPDATED WI TH
SI ZE 44° WX70° HX24° D APPROX.
PROPOSED 60' -1 -21
ELECTRI CAL CONDUI T
4A HOURS BEFORE YOU DIG \
CALL SUNSHINE
1 -800- 432 -4770
I T' S THE LAW 1 N FLORI DA
j
NO PAVEMENT
TO BE CUT
A TTSE
PROPOSED TELEPHONE FACILITIES
ON RIGHT OF WAY OF
MIAMI SHORES
210 NE 102ND ST
Exchange:
305751
Designer:
Bafna, Gitika
Phone:
305 - 222 -8237
Authorization:
9MP05034N
Dwg. 1 of 2
4/7/2009 11:58:51 AM
CABINET DETAIL
GAS I NET 51 ZE 1'2" WX2'2" 0X1-11-1
GONGK“ E PAS 51
V�f�TIGAL- VIEW
0 GAOINET
•
22s
CABINET
TOP VIEW
0i GA I NET
POWER
PEDESTAL
6'
ATTSE
PROPOSED TELEPHONE FACILITIES
ON RIGHT OF WAY OF
MIAMI SHORES
210 NE 102ND ST
Exchange:
305751
Designer:
Bafna, GTtika
Phone:
305 - 222 -8237
Authorization:
9MP05034N
Dwg. 2 of 2
4/7/2009 11:49:22 AM
J
9
VILLAGE OF V
JLFCTRICAJ
IAVII SHORS
RAWING
3
R/W
5' SIDEWALK
NE 102ND ST
3
EOP
GRASS AREA
----C/L-----------
EOP
GRASS AREA
R/W
w
J
J
DRIVEWAY
5' SIDEWALK AT &TTHHG
FPL CONTACT:
CARLOS BEALE
(305) 770 -7927 FPL
PROPOSED
ALP -248 CABINET
4'2•WX2'2'DX4'H
PROPOSED
FPL SERVICE POI NT —►
EOP
EXI STI NG
AT &T XBOX
EOP
ATTSE
PROPOSED TELEPHONE FACILITIES
ON RIGHT OF WAY OF
MIAMI SHORES - ELEC
210 NE 102ND ST
Exchange:
305751
Designer:
Bafna, Gitika
Phone:
305 - 222 -8237
Authorization:
9MP05034N
Dwg. 1 of 3
4/7/2009 11:57:23 AM
RT ADDRESS: 210 NE 102ND ST
3 "3 THWN
in 2' PVC
SCH 40 cond.
(Inside cabinet)
UL891- DEADFRONT SWITCHBOARD
E85938- EMERSON UL FILE NO.
3 "3
FACTORY PREWIRED
XFRS SWITCH
WITH 100 A
OCP
MECHANICAL INTERLOCK
TO PREVENT
SIMULTANEOUS 'TURN -ON°
100 A
100 A
3 "3
1 °8G
PANEL
100 AMPS
RATING
MLO
60/2
3
ci,
°3
1 °8 GROUND
O
GENERATOR
OUTLET
100 AMPS
RATING
PANEL P
SERVICE SCHEDULE
MAIN
CONDUCTORS
GROUNDING
CONDUCTOR
CONDUIT
AIC
100
AMPS
3 43 THWN
#6
2" PC
CONDUIT
IOK
TELEPHONE CABINET
PANEL P
3/4° C
3°6THWN
1 ° 10G
3 "3 THWN
in 2' PVC
SCH 80 cond.
(to FPL transformer)
1 °6
1 /2'C
GROUND
GROUND
° 6 SUPPL.
GROUND
FROM
FRAME TO
GROUND.
TOTAL LOAD: 35 AMPS
FPL CONTACT:
CARLOS BEALE
(305) 770 -7927 FPL
\"/
— N/A —
ATTSE
PROPOSED TELEPHONE FACILITIES
ON RIGHT OF WAY OF
MIAMI SHORES - ELEC
210 NE 102ND ST
Exchange:
305751
Designer:
Phone:
Bafna, Gitika
305 - 222 -8237
Authorization:
9MP05034N
Dwg. 2 of 3
4/7/2009 11:57:24 AM
* When installed. AC Power Pedestal should be
located within Oft of the cabinet. This permits the
pedestal to be grounded on the cabinet's buried
ring ground system.
* Use #2 AWG tin - plated bare solid copper wire for
all ground connections.
* Place minimum 6" of gravel in new Power
Pedestal and replace gravel in any existing AC
Power Pedestal re- entered.
Main AC
PWR Panel
1
#2 tinned GND Wire to $A1
if within 6ft of Cabinet
* Route ground wire from VRAD
Principal Bus Bar to the ground
rod and cad weld in a 3 -way
connection into the ground ring.
* Insure no -oxide is applied to
GND leads terminated on
Principal Buss Bar.
* Approved two (2) hole
compression connectors with
correct dye marking must be
used to connect the solid #2
conductor to the cabinet ground
buss.
#2
VRAD 7330 Bonding and Grounding
3 -way
Cad Weld
m��
3 -way
Cad Weld
Jog sgng lodpu;Jd OVmA
+0u!gD3 OVIA OEEL
Concrete Pad for DLC Cabinet
#2 AWG tin - plated bare solid copper wire
J
3 -way
Cad Weld
NOTE:
Place one (1) number 2 tinned ground wire from the ground ring up
into the splicing chamber and terminate the ground wire on the
principle ground point bus bar. Place an additional number 2 tinned
ground wire (separate from the first #2 ground wire above) from the
ground ring up into the splicing chamber and terminate the ground
wire on the principle ground point bus bar. The two (21 number 2
tinned ground wires should be connected to the ground ring utilizing
a Cad weld connection. The first ground wire will be attached on one
side of the ground ring and the second ground wire will be attached
at the opposite side of the ground ring (i.e. 180 degrees apart).
* Route GND wire from AC Sub PWR Panel direclly to nearest
GND rod per NEC code Section 250.
* Ground wire may not be spliced and should be routed as
directly as possible.
* The GND Ring must be below the frost line (See Notes).
:m The GND Ring must be a minimum of 12in below grade.
* GND Ring must also be approximately 6° to 24° from
the edge of the cabinet pad.
• 2 -way
Cad Weld
* Install minimum of four (4) (5/8° X 8° copper dad) ground rods.
* All connections to the ground ring inducing the attachment to
the ground rods will be Cad Weld connections. (Maximum 3 -way
Cad Weld connections) No 4 -way or above connections.
* All ground rods will be covered with a Flush Mount Ground Rod
Closure for inspection purposes.
* A minimum of 6° of gravel will be required in the ground rod
inspection window.
* Tag all ground conductors inside the inspection window with a
°C Tag.
* Place one (11#2 tinned ground wire from the ground ring up into the splicing chamber and terminate the ground wire on the principal ground point buss bar.
* Place an additional #2 tinned ground wire (separate from the first #2 ground wire above) from the ground ring for termination by qualified designated contractor
into the AC load center buss bar (AC Sub Electrical Panel). This panel is located in the splice chamber or attached to side of cabinet (as shown in figure above).
* The two (2) number #2 tinned ground wires should be connected to the ground ring utilizing a Cad Weld connection.
* The first ground wire will be attached on one side of the ground ring and the second ground wire will be attached at the opposite side of the ground ring (i.e. 180 degrees apart).
* The termination of the #2 tinned ground wire to the principal ground point bus bar in the splicing chamber should be connected utilizing a compression type connection with two (2) hole lug ( #10 -3/81.
Mechanical connections are NOT acceptable.
* Place one (1) #2 tinned wire from the VRAD principal ground point bus bar over to the SA1 buss bar. This attachment will provide bonding and grounding connectivity
between the SA1 and the VRAD. The minimum distance recommended in placing this ground wire from the VRAD to the SA1 is ten (10) feet. This procedure is best completed during
the placing of the copper cable between the VRAD and the SA1. (The placing process described above will allow the isolation of the ground source for testing purposes).
* Installations with multiple cabinets may be enclosed in the same ground ring if the separation between pads is 36 inches or less.
Equipment on pads separated by more than 36 Inches shall have a separate ground ring.
* Separate ground rings must be bonded together with a #2 AWG tin - plated bare copper conductor.
* All ground rods will be covered with a Flush Mount Ground Rod Closure. A minimum of 6 inches of gravel will be required in the ground inspection windows.
The gravel will be placed so that all ground connections are visible. Tag all ground conductors inside the inspection window and cabinet with a C tag.
* A minimum of 6 inches of gravel will be required in the cable entrance area.
ATTSE
PROPOSED TELEPHONE FACILITIES
ON RIGHT OF WAY OF
MIAMI SHORES - ELEC
210 NE 102ND ST
Exchange:
305751
Designer:
Bafna, GTtika
Phone:
305 - 222 -8237
Authorization:
9MPO5034N
Dwg. 3 of 3
4/7/2009 11: 57: 25 AM
3 -way
Cad Weld
m��
3 -way
Cad Weld
Jog sgng lodpu;Jd OVmA
+0u!gD3 OVIA OEEL
Concrete Pad for DLC Cabinet
#2 AWG tin - plated bare solid copper wire
J
3 -way
Cad Weld
NOTE:
Place one (1) number 2 tinned ground wire from the ground ring up
into the splicing chamber and terminate the ground wire on the
principle ground point bus bar. Place an additional number 2 tinned
ground wire (separate from the first #2 ground wire above) from the
ground ring up into the splicing chamber and terminate the ground
wire on the principle ground point bus bar. The two (21 number 2
tinned ground wires should be connected to the ground ring utilizing
a Cad weld connection. The first ground wire will be attached on one
side of the ground ring and the second ground wire will be attached
at the opposite side of the ground ring (i.e. 180 degrees apart).
* Route GND wire from AC Sub PWR Panel direclly to nearest
GND rod per NEC code Section 250.
* Ground wire may not be spliced and should be routed as
directly as possible.
* The GND Ring must be below the frost line (See Notes).
:m The GND Ring must be a minimum of 12in below grade.
* GND Ring must also be approximately 6° to 24° from
the edge of the cabinet pad.
• 2 -way
Cad Weld
* Install minimum of four (4) (5/8° X 8° copper dad) ground rods.
* All connections to the ground ring inducing the attachment to
the ground rods will be Cad Weld connections. (Maximum 3 -way
Cad Weld connections) No 4 -way or above connections.
* All ground rods will be covered with a Flush Mount Ground Rod
Closure for inspection purposes.
* A minimum of 6° of gravel will be required in the ground rod
inspection window.
* Tag all ground conductors inside the inspection window with a
°C Tag.
* Place one (11#2 tinned ground wire from the ground ring up into the splicing chamber and terminate the ground wire on the principal ground point buss bar.
* Place an additional #2 tinned ground wire (separate from the first #2 ground wire above) from the ground ring for termination by qualified designated contractor
into the AC load center buss bar (AC Sub Electrical Panel). This panel is located in the splice chamber or attached to side of cabinet (as shown in figure above).
* The two (2) number #2 tinned ground wires should be connected to the ground ring utilizing a Cad Weld connection.
* The first ground wire will be attached on one side of the ground ring and the second ground wire will be attached at the opposite side of the ground ring (i.e. 180 degrees apart).
* The termination of the #2 tinned ground wire to the principal ground point bus bar in the splicing chamber should be connected utilizing a compression type connection with two (2) hole lug ( #10 -3/81.
Mechanical connections are NOT acceptable.
* Place one (1) #2 tinned wire from the VRAD principal ground point bus bar over to the SA1 buss bar. This attachment will provide bonding and grounding connectivity
between the SA1 and the VRAD. The minimum distance recommended in placing this ground wire from the VRAD to the SA1 is ten (10) feet. This procedure is best completed during
the placing of the copper cable between the VRAD and the SA1. (The placing process described above will allow the isolation of the ground source for testing purposes).
* Installations with multiple cabinets may be enclosed in the same ground ring if the separation between pads is 36 inches or less.
Equipment on pads separated by more than 36 Inches shall have a separate ground ring.
* Separate ground rings must be bonded together with a #2 AWG tin - plated bare copper conductor.
* All ground rods will be covered with a Flush Mount Ground Rod Closure. A minimum of 6 inches of gravel will be required in the ground inspection windows.
The gravel will be placed so that all ground connections are visible. Tag all ground conductors inside the inspection window and cabinet with a C tag.
* A minimum of 6 inches of gravel will be required in the cable entrance area.
ATTSE
PROPOSED TELEPHONE FACILITIES
ON RIGHT OF WAY OF
MIAMI SHORES - ELEC
210 NE 102ND ST
Exchange:
305751
Designer:
Bafna, GTtika
Phone:
305 - 222 -8237
Authorization:
9MPO5034N
Dwg. 3 of 3
4/7/2009 11: 57: 25 AM