RF-09-561r Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Inspection Number: INSP- 110743 Permit Number: RF- 4- 09.561 Scheduled Inspection Date: April 29, 2009 Inspector:. Rodriguez, Jorge Owner: SHULMAN, STEVEN Job Address: 471 NE 101 Street Miami Shores, FL 33138 -2448 Project: <NONE> Contractor: ISAACS ROOFING & INSULATION CORP Permit Type: Roof Inspection Type: Roof Rartiew Work Classification: Flat Phone Number arcel Number 1132060170680 Phone: (305)234 -5234 Building Department Comments Infraction Passed Comments OWNER'S NOTIFICATION HVHZ ROOF APPLICATION PRODUCT APP ROOF MITIGiig ! ORMS 12% False False False False Passed —l� Failed Correction Needed Re- Inspection Fee No Additional Inspections can be scheduled until re- inspection fee is paid. Inspector Comments 4,/ G 4‘151111 kcal. Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 7952204 Fax: (305) 756.8972 BUILDING PERMIT APPOCATION FBC 2004 Permit Type (circle): MOMEWrfiri APR 0 71009 I BY.. -- -- �es_a_:_.e.e_. Permit No. V Master Permit No. Building Electrical Plumbing Mechanical Roofmg Owner's Name (Fee Simpl Titleholder) - -FE,)C .S .,`ebl.�g Owner's Address 1-1,11 C 1."0‘. — - City i1� I ,_ State IR Tenant/Lessee Name Phone # Zip Phone # Job Address (where the wok is being done) City Miami Shores Village County Miami -Dade FOLIO / PARCEL # Zip Is Building Historically Designated YES NO Contractor's Company Nai ie gk C.S , 9 Contractor's Address 0(24S s(A) 1S-1 s ( !- City M i Arent State Qualifier Name A1440, GA) A7....AACZ State Certificate or Registration No. e e, -z-sg. Architect/Engineer's Name (if applicable) Value of Work For this Permit $ Type of Work: ['Addition Describe Work: Phone it Z_711) Zip Phone # Certificate of Competency No. ['Alteration Phone # Square / Linear Footage Of Work: 80co S 7-FT ['New Er- Repair/Replace [' Demolition * * ** feet ** ****1** ** * *** ******** *** ** Submittal Fee $ t7in )) Permit Fee $ Notary $ '5 -OD T ining/Education Fee $ Scanning $ q -c Radon $ Bond $ Code Enforcement $ Structural Review. $ ** Feeess****** ******** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** p: CCF$a i-on Technology Fee $ Zoning $ DPBR $ Double Fee $ a Total Fee Now Due $ 4`: �C�; a ,, s See Reverse side --> Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS. and AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien itiw brochure will be delivered to the person whose property is subj ct to attachment. Also a cfc fied copy of the recorded notice of commencement must be posted at the job site for the first inspecti. whit j occurs seven �%) du after the building permit is issued In the absence of such posted notice, the inspection will not be .pro / ed and a reinsp �1 do f e will be charged i / Signature The foregoing ins day o who . Owner or Agent ent was a owledged bme�this -- fig , personall known to me or who has produced �% N1 . i • IU . ) 4. ; s identifirafinn and wht .i;�7 roLo NOT Sign: Print: PUBLIC: My Commission Expires: APPLICATION APPROVED BY: (Revised 02/08/06) Signature �-- Contractor The fore:o r g instrument was acknow%, ledged b pre me this ilit/ , day of ' �. 't g,.�� 21 by /6 whopersonally known me or who has produced as identification and who did take an oath. NOT PUBLIC: My Commission Expires: ` ;,;y`t1 . *** * * ** * * ** **** * * * * * **, ter** ** * ** *** ** * * ** * ** * **** *t r * * * * * * * * * * * ** v Plans Examiner Engineer Zoning NU I ICE OF COMMENCEMENT A RECORDED COPT MUST BE POSTED ON THE JOB SITE AT TIME OF FIRST INSPECTION \\'' 0 PERMIT NO. l W l TAX FOLIO NO. STATE OF FLORIDA COUNTY OF MIAMI -DADE: THE UNDERSIGNED hereby gives notice that improvements will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement. 1. Legal description of property and street/address: ( u6 I)J ST (ni e9 -•z7.3 Sii,® ,,,5 . CSI'`( �1�1if 1111110 CFN 2009R0282210 OR Bk 26833 Ps 11731 Ups) RECORDED 04/1712009 15:24:59 HARVEY RUM, CLERK. OF COURT MI AMI -DADE COMM FLORIDA LAST PAGE 2. Description of improvement: F-1 -�O� -((,e �[ -ro 3. Owner(s) name and address: S crcoJ I;Jm. J 4'7 ( & t o I S7- • Alb sit J' A..490-sS Interest in property: Name and address of fee simple titleholder. 4. Contractor's name and address: .S C /s)c2) 92 S- c,.) lS ^2 37. 5. Surety: (Payment bond required by owner from contractor, if any) Name and address: Amount of bond $ 6. Lender's name and address: ' 7. Persons within the state of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)7., lorida Statutes, Name and address: 8. In addition to himself, Owners designates the following person(s) to receive a,copy of the Uenor's Notice as provided in Section 713.13(1)(b), Florida Statutes. Name and address: 9. Ex ..• n date of differ :�i1 date is snec Sig ature of Owner Pri it Owner's Name .d of Commencement: (the expiration date is 1 year from the date of recording unless a S��crG� (S-h ✓/✓14^) Swom to and subscribed before me this I' day of iQ •; '' , 2001. Notary Public Print Notary's Nam My commission expires: 123.01-52 PAGE 4 5/05 Prepared by 4/„4ir3Ca'�- Address: gzgs 5 c-4) /51 Si. //414') Skart -CS - t� STATE OF FLORIDA, COUNTY OF DA! �E 1HE'i=BY CERTIFY that Boisis Qpyo;tfe origi 1 e n ti s once on 1 I rte' iii :�� A020 • , erd(f oia!Seal. ®yRf', � 1, r,`�;1C_of^Ms;uiY .d Courts D.C. Ift0OF ASSEMBUES AND ROOFTOP STRUCTURES Florida Building Code Edition 2004 High - Velocity Hurricane Zone Uniform Permit Application Form. Section A (General Information) ow lope ❑ Asphaltic . Shingles ROOF CATEGORY ❑ Mechanically Fastened Tile Metal Panel/Shingles ❑ Prescriptive BUR -RAS 150 ROOF TYPE ❑ New Roof eroofing ❑ Recovering ROOF SYSTEM INFORMATION ❑ Mortar /Adh ❑ Wood Shin ❑ Repair 0 11) JZ CO3 TEWIE1 APR 0 7 2009 DJ Cq- Low Slope Roof Area (SF) (jpc Steep Sloped Roof Area (SF) Total (SF) ey5O Section B (Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. MEM NM _1=111 11■ NNE num 111 11 Isimoran Numalirammi 15.32 Form AB -328 (page 4 of 9) Rev. 2/08 FLORIDA BUILDING CODE — BUILDING W o SUBJECT TO COMPLIANCE WITH ALL FEDERAL STATE AND COUNTY RULES AND REGULATION; a Pa6RMIT #:e iamihops Villa t Tice m kes :era API$ROVED ZONING DEPT 1 BLDG DEPT Low Slope Roof Area (SF) (jpc Steep Sloped Roof Area (SF) Total (SF) ey5O Section B (Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. MEM NM _1=111 11■ NNE num 111 11 Isimoran Numalirammi 15.32 Form AB -328 (page 4 of 9) Rev. 2/08 FLORIDA BUILDING CODE — BUILDING ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Florida Building Code Edition 2004 High - Velocity Hurricane Zone Uniform Permit Application Form. Surfacing: L 1 k- • Fastener Spacing for Anchor /Base Sheet Attachment: $ " q� Field: l� " oc @ Lap, # Rows Z. @ oc Perimeter: 1E2 oc @ Lap, # Rowsg @ " oc Corner: ! " oc @ Lap, # Rows Q_ @ 4 " oc Number of Fa teners Per Insulation Board: Section C (Low Slope Application) Fill in specific roof assembly components and identify manufacturer (If a component is not used, identify as "NA ") System Manufacturer: ����� ��' Product Approval No.: Q? > OAP P ° f° Design Wind Pressures, From RAS 128 or Calculations: Pmax1: WI. Z Pmax2: b Z Pmax3: .3 Max. Design Pressure, from the specific Product Approval system: e0C° Deck: Type :' 00t) - Gauge/Thickness: 1 a Slope: Anchor/Base Sheet & No. of Ply(s): (4 t0:L?L Anchor/Base Sheet Fastener/Bonding Material: ° Lehi" {2ie5� SkAr114- yp $' / (.G 3 5a /v Insulation Base Layer: Base Insulation Size and Thickness: Base Insulati n Fi,stener /Bonding Material: PI.® Moe ® 1 Top Insulation Layer: `r0pG S� `'Gr`—LAI, Top Insulation Size and Thickness: . I I1 Top Insulation Fastener/Bonding Material: VvoTAsp ix. fel k ° Base Sheet(s) & No. of Ply(s): /� I° vOA S LANs Base Sheet Fastener /Boning Material: ETA oeoE7 Atsr Field Perimeter Corner Illustrate Components Noted and Details as Applicable: Woodblocking, Gutter, Edge Termination, Stripping, Flashing; Continuous Cleat, Cant Strip, Base Flashing, Counter - Flashing, Coping, Etc. Indicate: Mean Roof Height, Parapet Height, Height of Base Flashing, Component Material, Material Thickness, Fastener Type, Fastener Spacing or Submit U `� cwitzo cpu PIy Sheet(s) & No. of Ply(s): 1 :Pt — Ply Sheet Fastener/Bonding `Materia�l. b 44 Top Pty: Top PIy FastenerBo ding Material: FLORIDA BUILDING CODE — BUILDING 2Aca -t FASeSry•o 12:kc:c- (Al ttfa —raire,<-v so 1404D, 66 sb FT . ° Parapet _Height _ � LO Mean Roof Height 15.33 1 SECTION R4402.13 HIGH VELOCITY HURRICANE ZONES — REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS R4402.13.1 Scope. As it pertains to the section, it is the responsibility of roofing contractor to provide the owner with the required roofing permit, and to explain to the owner the content of the section. The provisions of Section R4402 govern the minimum requirements and standards of the industry for roofing system installations. Additionally, the following items should be addressed as part of the agreement between the owner ant the contractor. The owner's initial in the designated space indicates that the item has been explained. Aesthetics- Workmanship; the workmanship provisions of Section R4402 are for the purpose of providing that the roof system meets the wind resistance and water instruction performance standards. Aesthetics (appearance) are not a consideration with respect to workmanship provisions. Aesthetic issues such as color or architectural appearance, that are not part of a zoning code, should be addressed as part of the agreement between the owner and the contractor. 2. --- Renailing wood decks: When replacing roofing, the existing wood roof deck may have to be renailed in accordance with the current provisions of Section R4403. (The roof deck is usually concealed prior to removing the existing roof system). ommon roofs: Common roofs are those which have no visible delineation between neighboring units (i.e., townhouses, condominiums, etc.) In buildings with common roofs, the roofing contractor and/or owner should notify the occupants of adjacent units of roofing to be performed. Exposed Ceiling: Exposed, open beam ceilings are where the underside of the roof decking can be viewed from below. The owner may wish to maintain the architectural appearance; therefore, roofing nail penetration of the underside of the decking may not be acceptable. The provides the option of maintaining the appearance. Ponding water: The current roof system and/or deck of the building may not drain well and may cause water to pond (accumulate) in low -lying areas of the roof. Ponding can be an indication of structural distress and may requiie the review of a professional structural engineer. Ponding may shorten the life expectancy and performance of the new roofing system. Ponding conditions may not be evident until the original roofing system is removed. Ponding conditions should be corrected. OvOverflow scuppers (wall outlets): It is required that rainwater flow off so that the roof is not overloaded from a buildup of water. Perimeter /edge wall or other roof extension may block this discharge if overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in accordance with the requirements of Sections R4402, R4403 and R4413. entilation: Most roof structures should have some ability to vent natural airflow through the interior of the structure assembly (the building itself). The existing amount of attic ventilation shall not be reduced. It may be beneficial to consider additional venting which can result in extending the service life of the roof. Owner /Agent's Signature Date Contractor Signature Date BUILDING CODE COMPLIANCE OFFICE (BCCO) PRODUCT CONTROL DIVISION NOTICE OF ACCEPTANCE (NOA) CertainTeed Corporation (PA) 1400 Union Meeting Road Blue Bell, PA 19422 MIAMI -DADE COUNTY, FLORIDA METRO -DADE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 MIAMI, FLORIDA 33130 -1563 (305) 375 -2901 FAX (305) 375 -2908 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by the BCCO and accepted by the Building Code and Product Review Committee to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The BCCO (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BCCO reserves the right to revoke this acceptance, if it is determined by BCCO that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code and the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: CertainTeed Modified Bitumen Roofing Systems Over Wood Decks LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement "Miami -Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA No. 08- 0227.09 and consists of pages 1 through 38. The submitted documentation was reviewed by Jorge L. Acebo, NOA No.: 08- 0410.09 Expiration Date: 06/19/13 Approval Date: 11/20/08 Page 1 of 38 ROOFING ASSEMBLY APPROVAL Category: Sub- Category: Deck Type: Maximum Design Pressure Roofing APP /SBS Modified Bitumen Wood -60 psf TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Product All Weather/Empire Base Sheet Flex- I -G1asTM Base Sheet Flex- I -G1asTM FR Base Sheet Flintglas® Ply Sheet Type IV or VI Flintlastic STA STA Plus 5.0 Flintlastic GTA, GTA -FR or Flintlastic Diamond GTA Flintlastic GTS Flintlastic GMS, GMS Premium Flintlastic FR, FR -P Premium Flintlastic FR Cap Sheet Dimensions 36 "x65'10'; Roll weight: 86 lbs. (2 squares) 36" x 98'9 "; Roll weight: 90 lbs. (3 squares) 39 3/8" x 50'; Roll weight: 90 lbs. (1.5 squares) 36" x 164'7 "; Roll weight: 40/55 lbs. (5 squares) 39 3/8" x 33'; Roll weight: 90 lbs. (1 square) 39 3/8" x 33' 3"; Roll weight: 105 lbs. (1 square) 39 3/8" x 24'9 "; Roll weight: 92 lbs. (% square) 39 3/8" x 34' 2"; Roll weight 100/105 lbs. (1 square) 39 3/8" x 34' 2 "; Roll weight: 105 lbs. (1 square) 39 3/8" x 34' 2 "; Roll weight: 90 lbs. (1 square) Test Specification ASTM D 4601 Type II UL Type 15 UL Type G2 ASTM D 4601, type 11 UL Type G2 ASTM D 4601, type II ASTM D 2178 Type IV or VI UL Type 01 ASTM D 6222, Grade S, Type II ASTM D 6222, Grade G, Type II ASTM D 6164, Grade G, Type II ASTM D 6164, Grade G, Type II ASTM D 6164, Grade G, Type I ASTM D 6163, Grade G, Type I Product Description Asphalt coated, fiberglass reinforced base sheet. Modified Bitumen coated fiberglass base sheet. Modified Bitumen coated fiberglass base sheet. Fiberglass, asphalt impregnated ply sheet. Smooth surfaced APP Modified Bitumen membrane with non- woven polyester mat reinforcement for torch application. Granule surfaced APP Modified Bitumen membrane with non- woven polyester mat reinforcement for torch application. Granule surfaced SBS Modified Bitumen membrane with non- woven polyester mat reinforcement for torch application. Granule surfaced SBS Modified Bitumen membrane with non- woven polyester mat reinforcement for mop application. Fire resistant, granule surfaced SBS Modified Bitumen Membrane with non -woven polyester mat reinforcement for mop application. Fire resistant, granule surfaced SBS Modified Bitumen membrane with fiberglass mat reinforcement for mop applications. NOA No.: 08- 0410.09 Expiration Date: 06 /19/13 Approval Date: 11/20/08 Page 2 of 38 Flintlastic FR Cap T Flintlastic FR Base T Flintlastic FR Cap CoolStar Flintlastic FR Cap T CoolStar Flintlastic GTA, GTA -FR CoolStar or Flintlastic Diamond GTA CoolStar Flintlastic GTS CoolStar Flintlastic GMS /GMS Premium CoolStar Flintlastic FR -P/FR P Premium CoolStar Flexiglas Premium Cap 960 CoolStar Flexiglas Premium Cap 960 APPROVED] 39 -3/8" x 34'2 "; Roll weight: 811bs. (1 square) 39 -3/8" x 33'; Roll Weight: 811bs. (1.0 squares) 39 3/ .." . ; Koll weight: 90 lbs. (1 square) 39 3/g" x 34' 2 "; Roll weight: 90 lbs. (1 square) 39 3/8" x 33' 3"; Roll weight: 105 lbs. (1 square) 39 3/8" x 24'9"; Roll weight: 92 lbs. (3/4 square) 39 3/8" x 34' 2 "; Roll weight: 100/105 lbs. (I square) 39 3/$" x 34' 2"; Roll weight: 105 lbs. (1 square) 36" x 34'6" (1 square) 36" x 34'6" (1 square) ASTM D6163 Granule surfaced SBS Modified Bitumen membrane with fiberglass mat reinforcement for torch application. ASTM D6163 Modified Bitumen, coated fiberglass base sheet for torch application. Ao 1 iri i) A163 Fire resistant, granule surfaced ' '13S Modified Bitumen membrane wits, .:',°rglass mat reinforcement for mop ann ications..:_ 'red with reflecij, CoolStar Coatin. ASTM D 6163 Fire resistant, granule surfaces: SBS Modified Bitumen membrane with fiberglass mat reinforcement for mop applications. Covered with reflective CoolStar Coating. ASTM D 6222 Granule surfaced, APP Modified Bitumen membrane with non- woven polyester mat reinforcement for torch application. Covered with reflective CoolStar Coating. ASTM D 6164 Granule surfaced, SBS Modified Bitumen membrane with non- woven polyester mat reinforcement for torch application. Covered with reflective CoolStar Coating. ASTM D 6164 Granule surfaced SBS Modified Bitumen membrane with non- woven polyester mat reinforcement for mop application. Covered with reflective CoolStar Coating. ASTM D 6164 Fire resistant, granule surfaced SBS Modified Bitumen Membrane with non -woven polyester mat reinforcement for mop application. Covered with reflective CoolStar Coating. Covered with reflective CoolStar Coating. ASTM D 6163, Granule surfaced SBS Modified Grade G, Type 1 Bitumen membrane with fiberglass mat reinforcement for mop application. Covered with reflective CoolStar Coating. ASTM D 6163, Granule surfaced SBS Modified Grade G, Type 1 Bitumen membrane with fiberglass mat reinforcement for mop applications. NOA No.: 08- 0410.09 Expiration Date: 06 /19/13 Approval Date: 11/20/08 Page 3 of 38 Ultra Poly SMS GlasBaseTM Base Sheet PoIySMS Base Sheet Yosemite Buffer Base Sheet Black DiamondTM Base Sheet Flintglaso Mineral Surfaced Cap. Sheet Flintglas® Mineral Surfaced Cap CoolStar 36" x 64'4" (2 squares) 36" x 98'9"; Roll weight: 69 lbs. (3 squares) 39 3/8" x 64' 4"; Roll weight: 90 lbs. (2 squares) 36" x 32'10"; Roll weight: 90 lbs. (1 square) 36" x 68'7"; Roll weight: 78 lbs. (2 squares) 36" X 32'10 "; Roll Weight 78 Ibs. (1 square) 36 "X32'10' ;Roll Weight: 78 lbs. (1 square) ASTM D 6164, Grade S, Type I ASTM D 4601 UL Type G2 ASTM D 6164 ASTM D 3909 ASTM D 4897 UL Type 30 ASTM D 1970 ASTM D 3909 ASTM D 3909 Smooth surfaced SBS Modified Bitumen Membrane with non- woven polyester mat reinforcement for mop applications. Asphalt coated, fiberglass base sheet. Modified Bitumen coated polyester base sheet. Mineral Surfaced fiberglass reinforced buffer sheet. Self- adhering fiberglass reinforced modified bitumen base sheet Asphalt impregnated and coated inorganic glass fiber surfaced with mineral granules used as the top ply in conventional built -up roof membranes. Asphalt impregnated and coated inorganic glass fiber surfaced with mineral granules used as the top ply in conventional built -up roof membranes. Covered with reflective CoolStar Coating. NOA No.: 08- 0410.09 Expiration Date: 06/19/13 Approval Date: 11/20/08 Page 4 of 38 APPROVED INSULATIONS: Product Name FlintBoard ISO ACFoam II ISO 95+ High Density Wood Fiberboard Perlite Insulation Dens Deck, Dens Deck Prime H- Shield ENRGY -3, UltraGard Gold, PSI -25 Fesco Board Multi -Max, FA APPROVED FASTENERS: Fastener Product Number Name 1. #12 & #14 Dekfast Fastener 2. Dekfast Hex Plate 3. Olympic Fastener #12 & #14 4. Olympic Standard 5. Insul -Fixx Fastener 6. Insul -Fixx S Plate 7. Tru -Fast Fasteners 8. Tru -Fast MP -3 9. Tru -Fast Plates 10. Tru-Fast Plates TABLE 2 Product Description Polyisocyanurate foam insulation Polyisocyanurate foam insulation Polyisocyanurate foam insulation Wood fiber insulation board Perlite insulation board Water resistant gypsum board Polyisocyanurate foam insulation Polyisocyanurate foam insulation Expanded mineral fiber insulation Polyisocyanurate foam insulation TABLE 3 Product Description Dimensions Insulation fastener Galvalume AZ50 steel plate 2'/8" x 3 '/4" Insulation fastener 3" round galvalume AZ50 3" round steel plate Insulation fastener for steel and wood decks Galvalume AZ50 steel plate 3" round Insulation fastener for wood and steel decks Galvalume AZ50 steel plate 3" round Galvalume AZ55 steel plate 3" round Polyethylene plastic plate 3" round Manufacturer (With Current NOA) CertainTeed Atlas Energy Products Firestone Building Products, Inc. generic generic G -P Gypsum Corp. Hunter Panels Johns Manville Johns Manville RMax, Inc. Manufacturer (With Current NOA) SFS Intec SFS Intec OMG OMG SFS Intec SFS Intec The Tru -Fast Corp. The Tru -Fast Corp. The Tru-Fast Corp. The Tru-Fast Corp. NOA No.: 08- 0410.09 Expiration Date: 06/19/13 Approval Date: 11/20/08 Page 5 of 38 EVIDENCE SUBM TTED: Test Aeencv Applied Research Laboratories Factory Mutual Research Corporation Underwriters Laboratories, Inc. United States Testing Company, Momentum Technologies, Inc. TrinitylERD Name Physical Properties Current Insulation Fastening Requirements TAS 114 /(FMRC 4470) UL 790 ASTM D 5147 ASTM D 4601 ASTM D 3909/ D 4897 TAS 114 (J) TAS 114 (J) TAS 114 (J)/TAS 117 (B) TAS 117(B) TAS 117 (B) TAS 114 (H) FM 4470, TAS 114 FM 4470, TAS 114 TAS 117 (B) ASTM Requirements Report Date 28013 06/02/87 FMRC 1994 01/01/95 J.I. #3Y8A1.AM 03/23/96 R11656 07/13/87 97457 -4 06/03/88 AX31G8D 09/05/08 AX31 G8C 09/05/08 43507.08.99 -1 04/18/01 #3514.02LAB 11/11/02 #3515.07.03 07/22/03 3503.10.06 10 /10/06 06490.04.07-RI 06/27/07 Letter 04/05/06 3533.01.06 01/06/06 3521.07.04 07/29/04 C8500SC.11.07 11/30/07 C10080.09.08 09/04/08 NOA No.: 08- 0410.09 Expiration Date: 06/19/13 Approval Date: 11/20/08 Page 6 of 38 Membrane Type: SBS MODIFIED Deck Type II: Wood, Insulated Deck Description: Minimum 19/32" thick plywood attached using approved nails spaced 4" o.c. at wood joists spaced maximum 24" o. c. System Type A(6): Anchor sheet mechanically fastened; all layer of insulation adhered with approved asphalt. All General and System Limitations apply. One or more layers of any of the following insulations. Insulation Layer Insulation Fasteners Fastener (Table 3) Density /ft2 ACFoam -H, UltraGard Gold, ENRGY -3, PSI -25, FlintBoard ISO, H- Shield Minimum 1.5" thick N/A N/A Perlite Minimum 3/4" thick N/A N/A High Density Wood Fiberboard Minimum V2" thick N/A N/A Dens -Deck, Dens -Deck Prime Minimum 1/4" thick N/A N /A. Note: All insulation shall be adhered to the anchor sheet in full mopping of approved hot asphalt within the EVT range and at a rate of 20-40 lbs /100 ft2. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulation listed as base layer only shall be used only as base layers with a second layer of approved top layer insulation installed as the final membrane substrate. Composite insulation panels may be used as a top layer placed with the polyisocyanurate side facing down. Anchor Sheet: One ply of All Weather/Empire Base Sheet, GlasBase or Flintglas Premium Ply Sheet (Type VI) mechanically attached as detailed below. Fastening: Anchor sheet shall be lapped 4" and fastened with 11 ga. annular ring shank nails and approved tin caps 8 "o.c. in the lap and three rows staggered in the center of the sheet 8 "o.c. Base Sheet: One ply of All Weather/Empire Base Sheet, Ultra Poly SMS, Glas Base, Flex -I Glas Base, Flex -I Glas FR Base or Poly SMS base adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20- 401bs. /sq. Ply Sheet: (Optional) One or more plies of Flintglas Ply Sheet (Type IV) or Flintglas P em' - (<T1pe.VfiJ-adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20- 401bs. /sq. or one ply of Black Diamond Base Sheet (for use with a torched cap sheet only) self adhered. NOA No.: 08- 0410.09 Expiration Date: 06/19/13 Approval Date: 11/20/08 Page 13 of 38 Membrane: Surfacing: One ply of Flintlastic GMS, Flintlastic GMS CoolStar, Flintlastic Premium GMS, Flintlastic Premium GMS CoolStar, Flintlastic FR -P, Flintlastic FR -P CoolStar, Flintlastic Premium FR -P, Flintlastic Premium FR -P CoolStar, Flintlastic FR Cap sheet, Flintlastic FR Cap Sheet CoolStar, Flexiglas Premium Cap 960, Ultra Poly SMS, Flintglas Mineral Surfaced Cap Sheet or Flintglas Mineral Surfaced Cap Sheet Cool Star adhered to base /ply sheet with approved mopping asphalt applied within the EVT range and at a rate of 20 to 401bsisq. or Flintlastic GTS, Flintlastic GTS CoolStar, Flintlastic FR Cap T or Flintlastic FR Cap T CoolStar torch adhered to base /ply sheet. (Optional) Install one of the following: 1. 400- 1b. /sq. gravel or 300- 1b. /sq. slag in a flood coat of approved mopping asphalt at an application rate of 601b.sq. 2. Karnak 97, FlintCoat A -150, APOC 212 Fibrated Aluminum, Henry 520 Aluminum or Grundy AL MB at an application rate of 1Y2 gal. /sq. Maximum Design Pressure: - 60psf. (See General Limitation #7) NOA No.: 08- 0410.09 Expiration Date: 06/19/13 Approval Date: 11/20/08 Page 14 of 38 WOOD DECK SYSTEM LIMITATIONS: 1. A slip sheet is required with Ply 4 and Ply 6 when used as a mechanically fastened base or anchor sheet. GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance, refer to a current Approved Roofmg Materials Directory for fire ratings of this product. 2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20- 40lbs.sq., or mechanically attached using the fastening pattern of the top layer 3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size shall be 4' x 4' maximum. 4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at each side lap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 12 Ibs.sq. Note: Spot attached systems shall be limited to a maximum design pressure of -45 psf. 5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F') value of 275 lbf., as tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field- tested, are below 275 lbf insulation attachment shall not be acceptable. 6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing, prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofmg Application Standard RAS 117. 7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred within this NOA, General Limitation #9 will not be applicable.) 8. All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs shall conform to Roofing Application Standard RAS 111 and applicable wind load requirements. 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners and corners). (When this limitation is specifically referred within this NOA, General Limitation #7 will not be applicable.) 10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9B -72 of the Florida Administrative Code. END OF THIS ACCEPTANCE NOA No.: 08- 0410.09 Expiration Date: 06/19/13 Approval Date: 11/20/08 Page 38 of 38 100 04/07/2009 68:46 3057518579 ABC MIAMI 2007 ROOFING MATERIALS AND SYSTEMS DIRECTORY - -e ROOF COVERING MATERIALS (TEVT) Roofing Systems (TGFU)— Continued Membrane: "Flintlastic STA ", "Flintlastic STA Plus ", "GTA ", "GTA Black Diamond' or "GTA White Diamond ", hot fused in place. 13. Deck: NC . Tndine:1 /4 Insulation: Polyisocyanurate, glass fiber, perlite, wine) fiber, 3 in. max, mechanically fastened. Base Slteek "Poly SMS Base Sheet ", mechanically fastened or adhered with hot roofing asphalt Ply Sheet: "Poly SMS Base Sheet", adhered with hot roofing asphalt. Membrane: "Flintlastic GMS ", adhered with hot roofing asphalt. Surfacing: Gravel. Class B - Ballasted 1. Deck NC Incline: 2 Insulation: Glass fiber, perlite, wood fiber, 24/2 in. max, mechanically fastened or adhered with hot roofing asphalt. Base Sheet: Type G2, mechanically fastened or adhered with hot roofing asphalt. Membranes "Flintlastic GMS ", "CMS Premium ", adhered with hot roofing asphalt Surfacing Gravel. 2. Deck: C -15/32 Incline 1/2 Insulation: Glass films perlite, wood fiber, 3/4 to 2 -1/2 in., joint in ' insulation must be offset 6 M. from joints in deck, mechanically fastened. Base Sheet Type GE mechanically . fastened or adhered with hot roofing asphalt. Membrane: "Flintlastic STA ", "Flintlastic STA Plus ", "GTA ", "GTA Black Diamond" or "GTA White Diamond ", heat fused. Surfacb g Gravel. 3. Deck. C -15/32 Incline: 1/4 Base Sheet Type GE mechanically fastened. Membrane ' "Flintlaatie STA ", "Flirttlastic STA Plus ", "GTA ", "GTA Black Diamond" or "GTA White Diamond ", heat fused.. Surfacing: Gravel, • 4. Deck C- 15/32• Incline: 1 "Atl joints blocked with 2x4's. Base Sheets Type G2, nailed, Membrane: "Plintlastic GMS ", "GMS Premium ", adhered with hot roofing asphalt. Surfacing Gravel. 5. Deck C -15/32 Incline: 1/4 Insulation: Celot "Hy -Tee ", 2 in. ?rein. joints in insulation must be offset 6 M. from joints in deck, mechanically fastened. Base Sheet Type G2, mechanically fastened or adhered with hot roofing asphalt, . •Membrane:. "Flintlastic GMS", "GMS Premium ", adhered with hot roofing asphalt. Surfacing; Gravel. 6. Deck C -]5/32 Incline: 1 /4 insulation: Celotex "Hy Ter ", 2 in min, joints in insulation must be offset 6 in. from joints in deck, mechanically fastened, Base Sheet Type G2, mechanically fastened or adhered with hot roofing asphalt. Membrane: "Plintlastic STA,', "Flintlastic STA Plus ", "GTA ", "GTA Black Diamond" or "GTA APP White Diamond ", heat fused. $urfadng: Gravel. Class A - FuIIy Adhered In lieu of anv membrane or membrane/surfacing shown below, "Flintlastic Ultra Poly SMS ", covered with gravel, may be utilized. I. Deck: NC Indine 1 Vapor Retarder (Optional) Type G2 "Glasbas2" base sheet or UL Classified vapor retarder. Insulation (Optional): One or more layers or combination of the following: UltraGard Premier, polyiaocyenurate, perlite, glass fiber nr wood fiber insulation. Base Sheet, One layer Type G2 "Glasbase" base sheet Membrane: One layer "Plintlastic GTA ( -3/4 sq or -1 sq), GTS" (modified bitumen), heat fused or "Plintlastic GMS ", hot mopped. Surfacing: APOC "No. 212 Fibrated Aluminum ", at 1 -1 /2 gal. lfltl sq /ft. 2. pecks NC Incline: 3/4 Vapor Retarder (Optional)_ Type G2 " Glasbase" base sheet nr UL Classified vapor retarder. Insulation (Optional): On' or more layers or combination of the following; Ultragard Premier. polyisocyanura +e, perlite, glass fiber or wood fiber insulation, Base Sheet One Layer of Type C;2 "Glasbase" base sheet. 4. 5, 6. 7. 8. 9. 1Q. 11, PAGE 01/01 ROOF COVERING MATERIALS (TEV) Roofing Systems (TGFU)— Cir+ttinued Membrane: One layer of "Flintlastic STA (modified bitumen), heat fused. Surfacing: Karnak "No. 97 Tibrated Aluminum ", at 1-1/2 gal. per 100 KM. Deck: C -15/32 Inclines 1/2 Insvtatioe (Optional): Schuller International "U]traGard Premier" polyieocyanurate, wood fiberboard, perlite, fiberglass, isocyanurate. any thickness. Base Sheet One or more plies of "Glasbase "; hot mopped or mecharti- cally fastened. Membrane: One ply of "Plintlestic FR" (modified bitumen), hot mopped in place Deck NC Incline: 1/2 Insulation: Polyisocyanurate, glass fiber, perlite, wood fiber, hot mopped or mechanically fastened, any thickness. Base Sheet: Type G2, mechanically fastened or hot mopped. Membranes "Flintlastic GTA or STA ", heat fused. Surfacing: Henry Co. "Henry 52a Aluminum ", applied at 1 -1/2 gal /a4. 1?ecks NC Incline: 1/4 Insulation (Optional); Glass fiber, perlite or wood fiber board. Ply Sheet Type G2, mechanically fastened. Membrane: "Plintlastic STA ", "Flintlastic STA Plus ", "GTA ", "GTA Black Diamond" or "GTA White Diamond ", heat fused. Surfacing Karnak Cherisical Corp. "Karnak No. 97", 1 gal /eq. Deck NC inclines 1 Insulation: Polyisoeyanurate, glass fiber, perlite, wood fiber, mecharil -° tally Fastened or adhered with hot roofing asphalt, any thickness. Base Sheets Type G2, mechanically fastened or adhered with hot roofing asphalt. Membranes "Flintlastic GMS ", "GMS Premium ", adhered with hot roofing asphalt.. Surfacing Karnak Chemical Corp. "Karnak No. 97 Fibrated Alumintun Asphalt Roof Coating", 2 -1/2 gal /sq. Deck: C- 15/32• • Indine:1 "A1i joints blocked with 2x4's. Insulation: Glass fiber, perlite, 3/4 in. min, joint in insulation must be offset 6 in, from joints in deck, mechanically fastened. Base Sheet Type GE mechanically fastened or adhered with hot roofing asphalt. Membrane: "Flintlastic GMS", adhered with hot roofing asphalt Surfadng Karnak Chemical Corp. "Karnak No. 97Fibrated Aluminum Asphalt Roof Coating ", 2 -1/2 gal /sq. Deck: NC Incline 1/2 Insulation: Polyisocyanurate, glass fiber, perlite, wood fiber, mechani- cally fastened or adhered with hot roofing asphalt, any thickness. Base Sheet Type G2; .mechanically fastened or adhered with hot roofing asphalt. Membrane: "Flintlastic STA ", "Flintlastic STA Pius ", "GTA ", "CIA Black Diamond" or "GTA White Diamond ", heat used in place, Surfacing Karnak Chemical'Corp. "Karnak No. 97 Fibrated Aluminum Asphalt Roof Coating ", 3 gal /sq. Deck: NC • Tncline 1 Insulation (Optional): Fertile, glass fiber, polyurethane, isocyanurate, phenolic combination isocyanurate /perlite, polyurethane /perlite or wood fiber, any thickness, hot mopped or nailed. Membranes ' Flirtrlastic STA ", "CI.A" "GTA Black Diamond ". "Fan- tastic GTA White Diamond ", "GMS", "GMS -5M ", "GMS Double Cover - age" or "GMS Premium ", heat fused or hot mopped in place. Surfacing: Grundy Industries, Inc. "al MB Aluminum Roof Coating" at 1 -2 goI /sq. Deck C -15/32 Incline:1 /4 Insulation (Optional): Any thickness po]yisocyaourate, glass fiber or perlite, mechanically fastened, joints in insulation must be offset 6 in. from joints in deck. Base Sheet: Type G2 base /ply sheet, mechanically fastened or hot mopped, Ply Sheet: Type 02 base /ply sheet, mechanically fastened or hot mopped. Membrane: "Flintlastic STA ", "Flintlastic STA Plus ", "GTA. White Diamond" or "CIA Sleek Diamond ". Surfacing: Grundy's "el MB Aluminum Roof Coating" at ] to 2 gal /sq. Deck NC Incline: 1/2 Insulation (Optional): Polyisocyorturate, glass fiber, partite, wood fiber, any combination, any thickness, mechanically fastened. LOOK FOR TltE UL MARK ON PRODUCT