EL-08-281Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Inspection Date: 03/11/2008 Inspector: Devaney, Michael Owner: SELZER, ALEXANDRA Job Address: 271 101 Street NE Miami Shores, FL 33138- Project: <NONE> Contractor: SHINE MAINTENANCE ELECTRICAL Permit Type: Electrical - Residential Inspection Type: Final Work Classification: Addition /Alteration Block: Phone Number 3051446 -0500 Parcel Number 1132060134810 Lot: Phone: (305)688 -2000 Building Department Comments Service upgrade 200 AMPS. Install new meter combo with space for breakers NAR 10 RED Passed Inspector Comments CREATED AS REINSPECTION FOR INSP- 75064. OUTSIDE IS OK. NNED TO SEE INSIDE PANEL MD 03/07/2008 ,F j,' ix,2_,e Failed Correction Needed Re- Inspection Fee ($75) No Additional Inspections can be scheduled re- inspection fee is paid. until Monday, March 10, 2008 Page 1 of 2 in Rte ei /i°o T Cori � "' ,Miami Shores Village Old► 1��1`� �J. Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 BUILDING PERMIT APPLICATI FBC 2004 Permit Type: Electrical tVitilrerEOVED] FEB 1 9 IMINSWISIPM Permit No. a 61-7.--Z Master Permit No. Owner's Name (Fee Simple Titleholder) ALE )CAN OR.j SEL_z.E2 Phone # Owner's Address 2. / /J G /0 City M. /Am WO /2,6- State F . Tenant/Lessee Name Zip 33/38 Phone # E -MAIL: Job Address (where the work is being done) 2. 9 ( N /0l sTee ET City Miami Shores Village County Miami -Dade Zip 3.3 / 2 8 FOLIO / PARCEL # Is Building Historically Designated YES NO S H I /Je MA 1N re (VAN cc EC.ECTIZi c/l C Contractor's,Company Name <0 A J n e Ac t ZS, CO R.fa - Phone # Contractor's Address 35.7 6 N tom) 12.s 5 TizEe, T City oPtit 2L,0 CA A State PL Zip $ 3.0 S y Qualifier Name F. G. 5 A AJ T L?S Phone # OS - 6861 - Z e)(52:1 State Certificate or Registration No. E c. 0 0 0 / S / q E -MAIL: Certificate of Competency No. Architect /Engineer's Nane (if applicable) Phone # Value of Work For this Permit $ 1 , 0 D 0. 0O Type of Work: ['Addition ['Alteration ['New Describe Work: 5 Cr 2 U/ J P Cc2'tDE 200 AMPS . 0 AA. (.m W / 71-1 5PACE FO2. a2- ,EA146-RS Square / Linear Footage Of Work: Repair /Replace ❑ Demolition IA) 7i4 LL /Vr W M C-T��2 WWWWW:xxxxxrxxrxrxxxxxrxxr. : xY* xxrxxxx Fees xrxxrww ,*w,wwwwwxww,nn Submittal FO'e $ Permit Fee $ Notary $ ,...� Scanning $'� Bond $ Training /Education Fee $ �1 Radon $ DPBR $ CCF $ O. (oO CO /CC Technology Fee $ Zoning $ Code Enforcement $ Double Fee $ Structural Review. $ Total Fee Now Due $ 1S1 W See Reverse side -� Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State °' Zip Application is hereby made to obtain a permit to do the work andiltAIlations ,as ' indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. 1 understand that a separate permit must be seeutpd for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS anid AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature �' G Owner or Agent The foregoing instrument was acknowledged before me this ` t.,°)_ day oFfela mi , 20 t by Ala 14 t e tQ 6E12EL who is personall known to me or who has produced 5L-tiate 6"-s D. As identifigatiA,R1-whlestitly e NOTARY P Sign: Print: �\Q.4 Jun '�,,,, My Commission Expires: Signature • �-h The foregoing instrument was acknowledged before me this day offeb'- ' ,20OX,by g: � � ° , who is personally known to me r who has produced as identification and who did take an oath. .`0"" ' Ansley juncO`� � PYPU �i la .�� = Commission # DD332081' e Cotnmi Sion # DD332081 2008 NOTARY PUBLIC• • d'. = .eQ Egpire�: JUNG 24, �:.... • :IP VP.. L 24, 2003 � iii �,�``�� Print: ��e.Lq kl �iiw�e AARONNOTARY.com My Commission Expires: -' Y.XX iCJ:XY YYX Y>: YYJ:) C*%X%% YX% 1C%.Y%'X iCX) C%% X% X% *X XXY. Y. Y. XY. Y. Y. X% XXXXY. Y. Y. XXXXXXX%'%' XXXY. Y.% Y.% XY. XXX Y. XXXXXXXY .Y.%Y.Y.XXXY.X%Y.XY.%X%XXX APPLICATION APPROVED BY: (Revised 02/08/06) //-4 'B Plans Examiner Engineer Zoning ER r'XANDRA 1V IDAL,LUIS 271 N.E. 101 STREET MIAMI SHORES, FL.33138 "EXISTING ELECTRICAL RISER OUTSIDE EXISTING METER 0 INSIDE EXISTING PANEL 'EXISTING 3 -# 2/0 THHNITHWN IN 1 1 /2 C. SHINE MAINTENANCE ELECTRICAL Master Electrician : CONTRACTORS CORP. Signature: 3876 INIW 125 ST. EC 0001514 Notar 4';.11,? Amsley junco OPA LOCKA FL.33054 .' = Commission # DD332081 :.rn�•: e = ' JUNE 24, 2198 "NEW ELECTRICAL TIER DIAGRAtr, •' AARONNOTARY.Com FPL OUTSIDE - IIISIDE Cr— NEW 3 # 2/0 THHNlTHWN IN 2" C. NEW METER COMBO 200 AMP 2010 A NEW # 4 Cu. (EGC) L � F3 NEW60A FOR FUTURE S W.POOL WCP EXISTING PANEL EXISTING 3 -# 210 THHN1THWN IN 1 1/2 C. FE3 2 4 2008 tie ` ufS -'ECT TO COT LIA ",10E VI! H ALL FEDERAL -- EGULAT!O�1S Job: SELSER ALEXANDRA I VIDAL,LUIS 271 N.E. 1 01 STREET MIAMI SHORES, FL .331 38 "EXISTING ELECTRICAL RISER EXISTING METER IHSIDE EXISTING PANEL 0 "-EXISTING 3 -# 210 THHNITHAN IN11/2C. FPL SHINE MAINTENANCE ELECTRICAL CONTRACTORS CORP. 3876 NW 125 ST. OPA LOCKA FL.33054 Master Electrician: F . San -OS EC 0001 51 4 "NEW ELECTRICAL RISER DIAGM9 -. ,P'' OUTSIDE NEW 3 # 2f0 THHNITHWN IN2 "C. NEW METER COMBO 200 AMP 1•1 200 A NEW 60 A FOR FUTURE S W.POOL WIDE EXISTING PANEL NEW # 4 Cu. (EGC) WCP FEZ 2 1, 2fl0� Anisley Junco ommission # DD332081 a: JUNE 24, 200 AARONNOTARY.com EXISTING 3 -# 210 THHNITHWN IN1112C. P IT #: ,O1S-2Js1 Miami Shores Village APPROV D BY DATE ZONING DEPT BLDG DEPT SUBJECT TO COMPLIANCE WI [H ALL FEDERAL STATE AND COUNTY RULES AND REGULATIONS