RF-09-1373s
Inspection Worksheet
Miami Shores Village
10050 N.E. 2nd Avenue Miami Shores, FL
Phone: (305)795 -2204 Fax: (305)756 -8972
Inspection Number: INSP - 127636
Scheduled Inspection Date: October 26, 2009
Inspector: Bruhn, Norman
Owner: RAUP, SUSANNE
Job Address: 824 NE 100 Street
Miami Shores, FL
Project: <NONE>
Contractor: AB MARTIN ROOFING
Permit Number: RF -8 -09 -1373
Permit Type: Roof
Inspection Type: Final Roof
Work Classification: Tile
Phone Number
Parcel Number 1132060340050
Phone: 305 -836 -2851
Building Department Comments
REROOF TILE VANGUARD ROLE
Passed
Failed
Correction
Needed
Re- Inspection
Fee
No Additional Inspections can be scheduled until
re- inspection fee is paid.
Inspector Comments
CREATED AS REINSPECTION FOR INSP- 127292. CREATED AS
REINSPECTION FOR INSP- 122291. tile
Remove all construction debri.
Provide uplift test
Remove debri
Cc_
October 23, 2009
For Inspections please call: (305)762 -4949
Page 15 of 17
6RY7AA ZZtA
Miami Shores Village r °
Building Department
10050 N.E.2nd Avenue, Miami Shores, Florida 33138
Tel: (305) 795.2204 Fax: (305) 756.8972
BUILDING
PERMIT APPLICATION
FBC 2004
i'TV c.,
OCT 0 X2009
Permit No. , F - 8 -o? - I3
Master Permit No.
Permit Type (circle): Building Electrical Plumbing Mechanical
Owner's Name (Fee Simple Titleholder) .SCE 544)A) f Riq c) P Phone # 3Q5 ° 75 i - 3 Fe c'
Owner's Address Rr4 9 ,tJ n e) _
City /W m . /0 (-2,S State p L
Tenant/Lessee Name
Zip 231.3
Phone #
Job Address (where the work is being done) 8a2 ,.) E % Ci
City Miami Shores Village County Miami -Dade Zip _33 / 3
FOLIO / PARCEL # `f 3 ?O 6 039 - 0 n --0
Is Building Historically Designated YES NO f-
Contractor's Company Name ,./3 'R Phone # 7 6 ` 308 C) e
Contractor's Address 36 7 /0 /3,5- j
City OPIQ State
Qna ifier Name r F N) ,)� m ®4,J Phone # _ -mac- C5'5 ° 77
State Certificate or Registration No. axon -7,2 On Certificate of Competency No.
Architect/Engineer's Name (if applicable)
Value of Work For this Permit $
Type of Work: ❑Addition
Describe Work: /
❑Alteration
Phone #
Square / Linear Footage Of Work:
❑New
❑ Repair/Replace ❑ Demolition
/
*************** * * * * * * * *FFeees * * * * * * * * * * * * * * * * **
Permit Fee $
CCF $
Note$`> Training/Education Fee $ Technology Fee $
Scanning $ Radon $ DPBR $ •
Bond $ Code Enforcement $ Double Fee $
Structural Review. $ Total Fee Now Due $
See Reverse side --->
Zoning $
Bonding Company's Name (if applicable) A y
Bonding Company's Address
City State Zip
Mortgage Lender's Name (if applicable)
Mortgage Lender's Address
City State Zip
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has
commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating "
construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS,
WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC
OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all
applicable laws regulating construction and zoning.
"WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR
PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING,
CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF
COMMENCEMENT."
Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must
promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person
whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site
for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the
inspection will not be approved and a reinspection fee will be charged.
Signature 4 // , f
Owner or Agent
The foregoing instrument was acknowledged before me this 30
day of 4iEP .. ,2006;, by 60,5x9.0,12 zR liap ,
who is personally known to me or who has produced
As identification and who did take an oath.
NOTARY PUBLIC:
Signature a,6
Co tractor
The foregoing instrument was acknowledged before me this
day of 5 , 20 , by
who is personally known to me or who has produced
as identification and who did take an oath.
NOTARY PUBLIC:
APPLICATION APPROVED BY:
(Revised 02/08/06)
Plans Examiner
Engineer
Zoning
Lab Report No. 09- 100095
Providing Solutions to the Roofing Industry
C.A. #: 26095
Lab Certificate: 08- 0514.02
CONCENTRATED UPLIFT LOAD TESTING ON ROOF TILE
TO COMPLY WITH METRO -DADE COUNTY PROTOCOL TAS -106
PROPERTY ADDRESS :: 824 NE 100 ST., Miami Shores
OWNER: Susanne Raup
CONTRACTOR: A B Martin Roofing
TILE TYPE: Double Roll
ATTACHMENT:: Poly Foam
•
PERMIT No: RF -8- 091374
ROOFING SQUARES: 30
ROOFPITCFL• 3:12
INSPECTOR INITIALS: NM/Hg
TEST DATE: 10 -17 -09
Required Testing Force: 35 Ibs
....,y �y...r
No.
... ...... ........
RESULT
... ..
No.
- . _
RESULT
- - ___-
No.
-- _ -
RESULT
No.
RESULT
No.
RESULT
1 -5
Passed
31 -36
Passed
6 -10
Passed
11 -20
Passed
21 -30
Passed
THIS ROOF HAS: PASSED I 1 FAILED 1 THE STATIC UPLIFT IN ACCORDANCE WITH MIAMI-
Reviewed by:
Alberto Cardona, P.E
Lic. No. 17138
"ROOF SKETCH"
Front
36' 10'
22'
595 W. 18th Street
Hialeah, FL 33010
12
11 8
10 7 6
14 5
15 9 i 26
17
19
16
20
22
21
25
24
27
23
3
29
30
34
36
28 31
35
33
FLAT AREA
www.floridatec.net
Tel: (305) 256 -4550
Fax (866) 333 -6988
36'
Inspection Worksheet
Miami Shores Village
10050 N.E. 2nd Avenue Miami Shores, FL
Phone: (305)795 -2204 Fax: (305)756 -8972
Inspection Number: INSP- 122292
Scheduled Inspection Date: October 22, 2009
Inspector: Bruhn, Norman
Owner: RAUP, SUSANNE
Permit Number: RF -8 -09 -1373
Job Address: 824 NE 100 Street
Miami Shores, FL
Project: <NONE>
Contractor: AB MARTIN ROOFING
Permit Type: Roof
Inspection Type: Up Lift Report
Work Classification: Tile
Phone Number
Parcel Number 1132060340050
Phone: 305 -836 -2851
Building Department Comments
REROOF TILE VANGUARD ROLE
Failed
Correction
Needed
Re- Inspection
Fee
No Additional Inspections can be scheduled until
re- inspection fee is paid.
Inspector Comments
fee ell44
October 21, 2009
For Inspections please call: (305)762 -4949
Page 11 of 34
OWNER 's Al FIDAVJT OF EXEMPTION
ROOD TO WALL CONNEC'T'ION HURRICANE MITIGATION RETROFIT FOR EXISTING Si'1"1:-
13111LT SINGLE FAMILY RESIDENTIAL STRUCTURES
PURSUANT TO SEcTioN 553.844 F.S.
�o a 08 ozco?
To: in /Ail --�$�/,Fk,RES ` �tuilding Department
/CO 50 Mee L' AJ� •
,41140? SKI ae.!'S FL.
Re: Owner's Name 505 ,4A) /t) RA0P
Property Address &: y Air /60 s7
Roofing Permit Number R - 8-d - /3)3
R s - 7 -09 - /l34/ '
Dear Building Official:
1 50 SA/006e RAOP certify that 1 am not required to retrofit the roof to wall
connections of my building because:
EThe just valuation for the structure for purposes of ad valorem taxation in less than $300,000.00.
The building was constructed in compliance with the provisions of the Florida Building Code
(FBC) or with the provisions of the 1994 edition of the South Florida Building Code (1994
SFBC).
Signature of Property O l er
jUSAit}N Ail OP
Print Name
STATE OF FLORIDA COUNTY OF MIAMI -DADE
Sworn to and subscribed before me this 0 8
day of 0C.7- , 2069
(SEAL)
✓Personally known
or Produced Identification
When the just valuation of the structure for purposes of ad v orem taxation is equal to or more than
$300,000.00, and the building was not constructed in compliance with the FBC nor with 1994 SFBC,
and affidavit of Roof to Wall Connection Hurricane Mitigation Retrofit Mint be provided.
C:Ulnmimrnh sad SddngebicMyUammrcub \Simimicsarerh.,,2VUafiq htridmfi (Lmplianer.4 xa 07rilleblralor
LICENSED AND INSURED
Job Address:
ROOFING, INC.
ARMAR?flN
3680 N.W. 135th Street • Opa Locka, Florida • 33054 836 -2851 681 -2852
SHEATHING AFFIDAVIT
8079 AE /06 �}
Name of Roofing Company: A.B. Markin Roofing, Tnc.
Name of Qualifier:
Address:
Permit No.:
A.R. Martin License No. C -OCbO 7200
377
3680 N.W. 135 Street Opa TLcka, Florida 33054
1,
A.B. Martin , do hereby affirm:
(Print Name of Qualifier)
That I have personally inspected the re- nailing of the existing roof sheathing as
required by Florida Building Code (FBC) Section 2322.2.8 for the area covered by the
roofing permit referenced above and further state that the re- nailing of the sheathing
meets the requirements of the current edition of the Florida Building Code sections
2322.2.
FBC Section 2322.2.2 Board roof sheathing shall have a net thickness of not less
than Y4 inch when the span is not more than 28 inches or 5/8 inch when the span is not
more than 24 inches, shall have staggered joints and shall be nailed with 8d common
nails not less than two in each 6 inch board nor three in each 8 inch board at each support.
FBC Section 2322.2.8 When existing roofs are re- roofed to the point that the
existing roofing is removed down to the plywood sheathing, the existing roof sheathing
shall. be re- nailed with 8d common nails (0.131 diameter by 2 -1/2" long with a 0.281
diameter full round head). Power driven 8d nails shall be of the same dimensions. Nail
spacing shall be six inches on center at panel edges, six inches on center at intermediate
supports, and where applicable 10d nails four inches on center over gable ends and sub -
fascia. Existing fasteners may be utilized to achieve such minimum spacing.
Qualifier Q tractor Signa e*
66/07-5
te
A.B. Martin
(Print Name of Qualifier /Contractor)
, having first been duly sworn, does affirm
the statement above to be true and correct by his own perso
ii/Personally known to me
(Seal/Stamp) Date
AFFIDAVIT OF COMPLIANCE WITH ROOF DECKING ATTACHMENT AND
SECONDARY WATER BARRIER HURRICANE MITIGATION RETROFIT FOR
EXISTING SITE -BUILT SINGLE - FAMILY RESIDENTIAL STRUCTURES
PURSUANT 1'0 SECTION 553.844 F.S.
Date: / 0 0 0 9 '
T0:fivAni 5/10 Building Department
mr. ?✓� s4,62E5, "L °
Re: Owner's Name ,e/le-V3
Property Address gw y ,) e ,zo S
Roofing Permit Number RF -8 -09 -/373
,r- -o9 -j/
Dear Building Official:
1, a. ig47/ , certify that the roof decking attachment and fasteners have
been strengthened and corrected and a secondary water barrier has been provided as required by
the "Manuel of Hurricane Mitigation Retrofits for Existing Site -Built Single - Family Residential
Structures" adopted by the Florida Commission by Rule 9B -3.047 F.A.C.
Qualifying Agent
Signature of
0 P . ''/rA2% iA-1
ifying Agent Print Name
SWORN TO AND SUBSCRIBED before me this 2d day of 1 c- J ,
2 , Q.4.3 %V) /07'U who: is personally known to me OR has
produced as 'identificaton and who executed the
foregoing instrument freely and voluntarily for the purposes therein expressed.
NOTARY PUBLIC, Late of Florida
At Large
MY COMMISSION EXPIRES:
Inspection Worksheet
Miami Shores Village
10050 N.E. 2nd Avenue Miami Shores, FL
Phone: (305)795 -2204 Fax: (305)756 -8972
Inspection Number. INSP- 122291 Permit Number. RF -8 -09 -1373
Scheduled Inspection Date: October 15, 2009
Inspector. Bruhn, Norman
Owner: RAUP, SUSANNE
Job Address: 824 NE 100 Street
Miami Shores, FL
Project: <NONE>
Contractor: AB MARTIN ROOFING
Permit Type: Roof
Inspection Type: Final Roof
Work Classification: Tile
Phone Number
Parcel Number 1132060340050
Phone: 305 -836 -2851
Building Department Comments
REROOF TILE VANGUARD ROLE
Passed
Failed
06 -7Y I
Correction
Needed
Re- Inspection
Fee
No Additional Inspections can be scheduled until
re- inspection fee is paid.
Inspector Comments
tile
/ZO �irC ge)/
koueex, 0"4-6-14"
October 14, 2009
For Inspections please call: (305)762 -4949
Page 7 of 20
Roof System Manufacturer:
Section D Sloped System Description
Tile Roof System
I LIFE TILE — /VI an/, c iS .
Notice of Acceptance Number (NOA):
Minimum Design Wind Pressures, If Applicable (from RAS 127 or Calculations):
kw -/emso
P 1:
P 2:
P 3:
BYo _____
Maximum Design Wind Pressures, (From the NOA Specific system):
Fill in the specific roof assembly components. If a component is not e nsf
required, Insert not applicable (rva) In the text pox.
Roof Slope:
"/12."
Roof Mean - Height: ft.
Method of Tile Attachment:
I Adheshremiel AIAPaddy Polyfoam Polypro-
Alternate Method of Tile Attachment per NOA:
Drip Edge Size & Gauge:
Drip Edge Material Type:
Drip Edge Fastener Type:
1-3" face 24 ga —
J— Galvanized Metal --
1 11/4 R.S Nails 4" O/C
Hook Strip/Cleat gauge or weight
Deck Type:
I —1' x 61 T 84 G-
Optional Insulation:
IN/A
Optional Nailable Substrate:
IN /A
Optional Nailable Substrate p t: : • • :: •`�
�.•�N• 7 • • •
Basesheet Type: •• o. •i• • • •
I # 30 ASTM '`�' . I141_1 %' � l f
•• .. ••
Fastener Type for Basesheet ihenh' • '
111/4 R.S Nails & 1 5/8 in.Ca ' •• • •'
• •t •
Tite Underlaymen+ (Cap oL eet j( :.__.
0
Tile Underlayment Attachment Method /
t- 6 cu Ara/z. -° / a
Tile Profile:
1 VAN GUr9 RA Pew- L• I
•
•
• •
• •
fir, �1 :
51
Miami Shores Villacc7
APPROVED
BY
DATE
ZONING DEPT
•
BLDG DEPT
•
/G%
SUBJECT TO COMPLIANCE WITH ALL FEDERAL
STATE AND COUNTY RULES AND REGULATIONS
,4 EA/ v m /) Y
Florida Building Code Edition 2002
Velocity Hurricane Zone Uniform Permit • , R=ation Form.
Section E (Tile Calculations)
For Moment based tile systems, choose either Method 1 or 2. Compared the values
for Mowith the valves from M i. If the Mf values are greater than or equal to the Mr
values, for each area of the roof, then the tile attachment method is acceptable.
Method 1 "Moment Based Tile Calculations Per RAS 127" • g
(P1: 41.5 z ?a°20.m 13 Mg: ;97 Ma 7•" NOA Mf4?-6-
(P2: 7753.6 z to >28 2 ,'3 -Mg: '�i:17 = A1iz.._i .14 NOA Mf
(P3: i /e,' $ z A = 33-4)- Mg: 5:7) -Ma ' 6 NOA Aff /IC'
Method 2 "Simplified Tile Calculation Per Table Below"
Required Moment of Resistance (M,) From Table Below NOA Mf
Mr Required Moment Resistance*
Description
Moan Roof Height
15'
20'
25'
30'
Mean Roof Height
40'
-
Roof Slope [
2:2
34.4
38.5
31.2
39.7
NOA
42.2
3:12
32.2
34.4
31.0
37.4
Required Moment Resistance
39.8
: ?..
4:12
30.4
322
33.8
35.1
Fr
5:12
28.4
30.1
31.8
: 32.t:
•
X30.5
•
" _34.9
8:12
28.4
28.0
29.4
• 32.4• •
•
7:12
24.4
25.9
27.1
• .78
•
30i0
..••
*Must be used in conjunction with a list of moment based tile systems endorsers optihe
Broward County Board of Rules and Appeals. • • • • • • :
•• •• •.
For Uplift based file systems use Method 3. Compared the valves for F'•tite
values for F,. If the F' values are greater than or equal to the Fr values, for eaeh
area of the roof, then the tile attachment method is acceptable. • • •
Method 3 "Uplift Based Tile Calculations Per RAS 127" ••••
(PI : z1: _ : w:= ) -W: cos 8: = F : NOA F'
(P2 : z I: = a w: _ ) - W: a cos B: _ = F,2: NOA F'
(P3 : z 1: = z w: = ) - W: : cos B: _ = F,r3: NOA F'
• •••
• •
•
...•
••••
Where_ to Obtain Information
Description
Symbol
Where to find
Design Pressure
P1 or P2 or P3
RAS 127 Table 1 or by an engineering analysis prepared by PE based on ASCE
7
Mean Roof Height
H
Job Site
Roof Slope
g
Job Site
Aerodynamic Multiplier
a,
NOA
Restoring Moment due to Gravity
Mg
NOA
Attachment Resisbnice
Mr
NOA
Required Moment Resistance
Mr
Calculated
Kmmntm Attachment Desistance
F
NOA
Requited Uplift Resistance-
Fr
Calculated
Avers Tile Weight
W
NOA
Till Dimensions
length
w= width
NOA
All calculations must be submitted to tie Building Official at the time ofpemritapplication.
••••
•
••••4
•
••••'
•
•.••l
•
•
123_01 -48 5/03 PAGE 5
MIAMI•DADE
BUILDING CODE COMPLIANCE OFFICE (BCCO)
PRODUCT CONTROL DIVISION
NOTICE OF ACCEPTANCE (NOA)
Monier Lifetile, LLC
200 Story Road
Lake Wales, FL 33898
MIAMI -DADE COUNTY, FLORIDA
METRO -DADE FLAGLER BUILDING
140 WJiST N AGLER STREET, SUITE 1603
MIAMI, FLORIDA 33130 -1563
(305) 375 -2901 FAX (305) 375-2908
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials.
The documentation submitted has been reviewed by Miami -Dade County Product Control Division and accepted
by the Board of Rules and Appeals (BORA) to be used in Miami Dade County and other areas where allowed by
the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control
Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to
have this product or material tested for quality assurance purposes. Hillis product or material fails to perform in
the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately
revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserve jla ght
to revoke this acceptance, if it is determined by Miami -Dade County Product Control Di$isigftbat thiS product or
material fails to meet the requirements of the applicable building code.
• • • • • • • • •
This product is approved as described herein, and has been designed to comply with the Floiri,d,p Building J qde
including the High Velocity Hurricane Zone of the Florida Building Code.
••••
••••
DESCRIPTION: Vanguard Roll Concrete Roof Tile
•
•• ••
••• •
• •
••
LABELING: Each unit shall bear a permanent label with the manufacturers name or logo, c'itA state aid, • •
following statement: "Miami -Dade County Product Control Approved ", unless otherwisenote4 herein.• • • • • •
RENEWAL of this NOA shall be considered after a renewal application has been filed atarithere bias, Tina
change in the applicable building code negatively affecting the performance of this product. • •
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or cli.alige in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any
product, for sales, advertising or any other purposes shall automatically terminate this NOA. FailurF GG i bmply
with any section of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade Coumy, Florida, and folibwed by
the expiration date may be displayed in advertising literature. If any portion of the NOA. is cisplayed, then it shall
be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manuf a::ure, or its distributors
and shall be available for inspection at the job site at the request of the Building Official.
This NOA consists of pages 1 through 7.
The submitted documentation was reviewed by Alex Tigera.
NOA No.: 07-1023.07
Expiration Date: 12/16/12
Approval Date: 12/20/07
Page 1 of 7
•
•
•
•
•
•
•
• •
•
• •
•
•
•
•
ROOFING ASSEMBLY APPROVAL
Category:
Sub - Category:
Material:
Roofing
Low Profile Roofing Tiles
Concrete
1. SCOPE
This renews a system using Monier Lifetile Vanguard Roll Concrete Roof Tile, as
manufactured Monier Lifetile LLC in Pompano Beach, FL. and described in Section .2 of this
Notice of Acceptance. For locations where the pressure requirements, as determined by
applicable Building Code does not exceed the design pressure values obtained by calculations in
compliance with RAS 127 using the values listed in section 4 herein. The attachment calculations
shall be done as a moment based system.
2. PRODUCT DESCRIPTION
Manufactured by
Applicant
Monier Lifetile LLC
Vanguard Roll Tile
Trim Pieces
Test
Dimensions Specifications
1 = 16 -1/2"
w = 13"
1 /z" thick
1= varies
w = varies
varying thickness
2.1 SUBMITTED EVIDENCE:
Test Aiency
Redland Technologies
Redland Technologies
Redland Teclurologies
The Center for Applied
Engineering, Inc.
The Center for Applied
Engineering, Inc.
Redland Technologies
TAS 112
TAS 112
Test Identifier
Product
Description
Low profile, interlocking, high pressure
extruded concrete roof tile equipped with one
nail hole and double roll ribs. For direct•dacic•
or battened nail -on, mortawadiesive say •
applications. •
Accessory trim, concrete reef pieces for use
at hips, rakes, ridges and yey lermim it ams•
Manufactured for each tile'ptbfile. ••••
•. • •
• . • •
•• •• ••
• ..
•
• • ••••
Test Name/Report , • • • • • ID�a c. •:. •
• 7161 -03 Static Uplift Testing Dec. !St % • •
Appendix IlI PA 102 & PA 102(A) . .
7161 -03 Wind Tunnel Testing Dec. 1991
Appendix II PA 108 (Nail -On)
P0402 Withdrawal Resistance Testing of Sept. 1993 -
screw vs. smooth shank nails
94 -060B Static Uplift Testing March, 1994
PA 101 (Adhesive Set)
94 -084 Static Uplift Testing May 1994
PA 101 (Mortar Set)
P0631 -01 Wind Tunnel Testing July 1994
PA 108 (Mortar Set)
NOA No.: 07-1023.07
Expiration Date: 1211.6112
Approval Date: 12/20/07
Page 2 of 7
Test. Agency
Redland Technologies
The Center for Applied
Engineering, Inc.
The Center for Applied
Engineering, Inc.
The Center for Applied
Engineering, Inc.
The Center for Applied
Engineering, Inc.
Celotex Corporation
Testing Services
Walker Engineering, Inc.
Wacker Engineering, Inc.
Walker Engineering, Inc.
Walker Engineering, Inc.
Walker Engineering, Inc.
Walker Engineering, Inc.
Walker Engineering, Inc.
Nutting Engineering
Test Identifier
Letter Dated Aug. 1,
1994
Project No. 307025
Test #MDC -760
.25- 7183 -1
25- 7183 -2
25- 7214 -2
25- 7214 -6
528454 -2 -1
520109 -2
Calculations
Evaluation Calculations
Evaluation Calculations
Evaluation Calculations
Evaluation Calculations
Evaluation Calculations
Evaluation Calculations
TAS -112
Test. Name/Report.
Wind Tunnel Testing
PA 108 (Nail -On)
Wind Driven Rain
PA 100
Static Uplift Testing
PA 102
(2 Quik -Drive Screws, Direct
Deck)
Static Uplift Testing
PA 102
(2 Quik -Drive Screws, Battens)
Static Uplift Testing
PA 102
(1 Quik -Drive Screw, Direct Deck)
(1 Quik -Drive Screw, Battens)
Static Uplift Testing
PA 101
Aerodynamic Multiplier
25 -7183
25 -7094
25 -7496
25 -7584
25- 7804b -8
25- 7804 -4 & 5
25- 7848 -6
Date
Aug. 1994
Oct. 1994
Feb. 1995
Feb. 1995
March, 1995
Sep. 1998
Dec. 1998
Augur X2007.
• .• ch :Inn.
• ... ��bm' 1Yin•
▪ April 1996
....
••••
'•.••. Dece%. •
1994. .
••
•• •• ••
•
• • •
• Aerodynamic Multipliers. .October • • 7• ▪ •
Two Patty Adhesive Set Sysid? • Aprti ?929•.
13343.1 - June 21Z7 •
a
t. = 1 a s O F
1• -
NOA No.: 07-1023.07
Expiration Date: 12/16/12
Approval Date: 12/20/07
Page 3 of 7
3. LIMITATIONS
3.1 Fire classification is not part of this acceptance.
3.2 For mortar or adhesive set tile applications, a static field uplift test shall be performed in
accordance with RAS 106.
3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform
quarterly test in accordance with TAS 112, appendix `A'. Such testing shall be submitted to
the Building Code Compliance Office for review.
3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications
Standards listed section 4.1 herein.
3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope
unless stated otherwise by the underlayment material manufacturers published literature.
3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in
compliance with applicable building code.
4. INSTALLATION
4.1 Monier Lifetile Vanguard Roll Concrete Roof Tile and its components shall be installed in
strict compliance with Roofing Application Standard RAS 118, RAS 119, and RAS 120.
4.2 Data For Attachment Calculations
Table 1: Average Weight (W) and Dimensions (I x w) • • •
•• • ....
Tile Profile
Weight -W (lbf)
Length -I (ft)
• • •liMifilth -w I • • • •
Monier Lifetile Vanguard Roll
Tile
9.2
1.38
•••• 1.08 • • • •
• •
•••• ••••
•
•• ••
• •
••
Table 2: Aerod
namic Multi • tiers - ?. ft • •
•••••
Batten Application Direct t� ipplicition
.0.289
•
Tile
Profile
Monier Lifetile Vanguard Roll Tile
0.266
•
•
•
• •
• •
• •
•
•.
• •
• •
Tile
Profile
Monier
Lifetile
Vanguard
Roll Tile
2 " :12"
Table 3: Restoring Moments due to Gravity - M, (ft-ltf)
3%12" 4 ":12" 5 ":12"
Battens
5.30
Direct
Deck
Battens
Direct
Deck
Battens
Direct
Deck
Battens
Direct
Deck
, :.211
Batten
6.03 5.24 5.97 5.16
5.87 5.05
5.75
i)irect
Deck
7 ":12" or
greater
Direct
Deck
4.92 —1.60 4.78 5.44
Battems
J
NOA No.: 07. 1023.07
Expiration Date: 12/16/12
Approval Date: 12/20/07
Page 4 of 7
Table
4: Attachment Resistance
Fastener Type
•
Expressed
for Nall-On Systems
Direct Deck
(min 15/32"
plywood)
as a Moment - Mr (ft-Ibf)
Direct Deck
(min. 19/32"
plywood)
Battens
Tile
Profile
Monier Lifetile
Vanguard Roll
Tile
2 -10d Ring Shank Nails
27.8
5 Medium paddy placement of 24grams of PolyProrM.
37.4
28.8
1 -10d Smooth or Screw
Shank Nail
8.8
11.8
4.1
2 -10d Smooth or Screw
Shank Nails
16.4
21.9
7.1
1 #8 Screw
25.8
25.8
22.9
2 #8 Screw
47.1
47.1
49.1
1 -10d Smooth or Screw
Shank Nail (Field Clip)
24.3
24.3
24.2
1 -10d Smooth or Screw
Shank Nail (Eave Clip)
19.0
19.0
22.1
2 -10d Smooth or Screw
Shank Nails (Field Clip)
35.5
35.5
34.8
2-10d Smooth or Screw
Shank Nails Eave Cll.
31.9
31.9
32.2
•
___1
•
1 •
•
•• • • • • • •
• •
••••
Table 6: Attachment Resistance Expressed as a Moment
for Two Patty Adhesive Set Systems
M} fit •
• •••• • • • • • • e_
Minial Attachmetft
•Pgsistance •.:
• • • • Z•13 • •
• •
Tile
Profile
. Tile Application
Monier Lifetile Vanguard Roll Tile
Adhesive`
1 See manufactures corn. onent a. . royal for installation re•uirements. • • • • •
2 Flexible Products Company TileBond
Polyfoam Product, Inc. Average weight
Average weight per patty 11.4 grams. •• • • •.
per patty 8 grams. • -•- •
Table 7: Attachment Resistance Expressed as a Moment - Mr (t-lbf)
for Single Patty Adhesive Set Systems
Tile
Profile
Tile Application
Minimum Attachment
— Resistance,
86.614
Monier Lifetile Vanguard
Roll Tile
Polyfoam PoIyProTM
Polyfoam P0IyPr0TM
45.5y
3 Large paddy placement of 54grams of PoIyProTM.
5 Medium paddy placement of 24grams of PolyProrM.
NOA No.: 07- 1023.07
Expiration Date: 12/16/12
Approval Date: 12/20/07
Page 5 of 7
•
Y •
• •
•
• •
Table 8: Attachment Resistance Expressed as a Moment • M1 (ft-Ibf)
for Mortar Set Systems
Tile
Profile
Tile
A • • lication
Attachment
Resistance
Monier Litetile Vanguard Roll Tile
Mortar Sets
20.60
5. LABELING '
Al] tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as
shown below, or following statement: "Miami -Dade County Product Control Approved ".
VANGUARD ROLL
MONIERLIFETILE LLC, VANGUARD ROLL TILE IDENTIFICATION MARK •
(POMPANO, FL PLANT) • • •
•
LOCATED UNDERNEATH TILE • • • • •
•
•
••.••
• •
••••
•
•
•
•
• •
6. BUILDING PERMIT REQUIREMENTS •• • • • •• • • • •
6.1 Application for building permit shall be accompanied by copies of .the following` • • • • • • •
6.1.1 This Notice of Acceptance. • •
6.1.2 Any other documents required by the Building Official or Dyable building • • •
•
code in order to properly evaluate the installation of this system: . • • • • •
• r•
• •,.••
• . • • •
• •, • •
NOA No.: 07.1023.07
Expiration Date: 12/16/12
Approval Date: 12/20/07
Page 6 of 7
PROFILE DRAWING
•
• •
••••
• •
•• ••
• • •
• •
• •
MONIER LIFETILE VANGUARD ROLL CONCRETE ROOF TILL.. •
END OF THIS ACCEPTANCE
• •
•
•
•••• •
• , • • •
••••
• • •
•••• • •
• •
••••
••• •
• •
••
0
••Sy
•' •
••••
• •
•
•
•
• •
• •• , ♦„ , •
• •' •
NOA No.: 07- 1023.07
Expiration Date: 12/16/12
Approval Date: 12/20/07
Page 7 of 7
Miami Shores Village
Building Department
10050 N.E.2nd Avenue, Miami Shores, Florida 33138
Tel: (305) 795.2204 Fax: (305) 756.8972
BUILDING
PERMIT APPLICATION
FBC 2004
Permit Type (circle): Building Electrical Plumbing
Owner's Name (Fee Simple Titleholder) 5 () -5,4 /thr,) E RA OP
Owner's Address a V /) G /0C
City in he4 fl'/ .5 / State giQ L, pQ a
Permit No.
Master Permit N .
NECMZWMN
RR AUG 17 200
If D,
Mechanical
Phone #
Zip 3 s /3cP
Roofing
Tenant/Lessee Name Phone #
Job Address (where the work is being done) 8
City Miami Shores Village County Miami -Dade 1'LA° Zip
FOLIO / PARCEL # i f — - ® 3 ei! - co J`
Is Building Historically Designated YES NO ✓�
Contractor's Company Name 0 , a / , /277Ai
Contractor's Address 77 c / 8 `S s 7'
City OPALI, C.-/K $ State pc., Zip �3 63' 'c/
Qualifier Name q, 6 r AA / I T7 Id Phone # '405' --� #," 77 4'O
3 3/ 38
Phone # 7%
State Certificate or Registration No. etren ?0`2 ®® Certificate of Competency No.
/0/P't
Architect/Engineer's Name (if applicable)
Value of Work For this Permit $
Type of Work:
Describe Wo
16,(30
Phone #
Square / Linear Footage Of Work:
Addition []Alteration []New
iF���i ►tlil� Jl %/ /�rTiti_���II��= +ia'�r�i.� -`
Repair/lteplace
SOO
[] Demolition
CL
***************************************pees******************* **********************
Permit Fee $ 800 r CCF $ 10Q0
..r
Submittal Fee $ 5D 4253-
CO /CC
Notary $ Training/Education Fee $ 3 ' Technology Fee $ 130
Scanning $ (0'00 Radon $
Bond $ Code Enforcement $
DPBR $
Double Fee $
Zoning $
Structural Review. $ Total Fee Now Due $ • 10
e,t- X172
See Reverse side -->
Bonding Company's Name (if applicable)
Bonding Company's Address
Ci ty State / Zip
Mortgage Lender's Name (if applicable)
Mortgage Lender's Address
City State Zip
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that.no work or installation has
commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating
construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS,
WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC
OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all
applicable laws regulating construction and zoning.
"WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR
PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING,
CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF
COMMENCEMENT."
Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must
promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person .
whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site
for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the
inspection will not be approved and a reinspection fee will be charged.
Signature ,(J
Owner or Agent
The foregoing instrument was acknowledged before me this /4
day of Ac , 20Cq , by 505,44,0t... Arat.Xi°
who is personally known to me or who has produced
As identification and who did take an oath.
NOTARY PUBLIC:
Sign:
Print:
C
My Commission Expires:
* * * * * * * * * * * * * * * * * * * **
APPLICATION APPROVED BY:
(Revised 02/08/06)
LOUISE MARTIN
're m ton DD 697755
ki Expires August 26, 2011
Bonded TM, TroyFain
* **
Signature
a (8-
Cghtractor
The foregoing instrument was acknowledged before me this if/
day of ,4O , 2001, by q ,Q MJ4®2T /A ,
who is personally known to me or who has produced
as identification and who did take an oath.
* **
NOTARY PUBLIC:
Sign:
Print:
A toa5,- /v»27'/A-)
My Commi. Sinn FxpirPc.
mmissi n
r Expires August 26, 2011
* * * * * * * * * * **
Itiui
,NI Bonded Thru Troy Fain Insurance 800996.7019
Plans Examiner
Engineer
Zoning
* * *,r< * **
NOTICE OF COMMENCEMENT 1111111 I ii 11111 1111 111 1 111111!1111111111
A RECORDED COPY MUST *3,E POSTED ON THE JOB SITE AT TIME OF FIRST INSPECTION
PERMIT NO. TAX FOLIO NO.
SPATE OF FLORIDA:
COUNTY OF MIAMI - DARE:
THE. UNDERSIGNED hereby gives notice that improvements will be made to certain real
property, and in accordance with Chapter 713, Florida Statuses, the following information
is provided in this Notice of Commencement.
C:F14 21- 109RO49-357 2
OR P.k 26932 F's 2711; (1P9)
RECORDED 07109/2009 09 :33 :54
HARVEY lti:liV'INr CLERK. OF COURT
MIAMI-GAGE COUNTY FLORIDA
LAST PAGE
1. Legal description of property and street/address: i51,:q '/ I1)L /O )
2. Description otimprovement: - FLAT I JLiE
3. Owner(s) name and address: SVS/IJU/)t" ).",AO, g,WA,E )Lan S�7
ICI A //
ffe
Interest in property: f IC C- E 1/1")
Name and address of fee simple titleholder:
4. Contractor's name and address:
5. Surety: (Payment bond required by owner from contractor, if any)
Name and address:
Amount of bond $
6. Lender's name and address:
/11
7. Persons within the state, of Florida designated by Owner upon whom notices or other documents may be served as
provided by Section 713.13(1)(a)7., Florida Statutes,
Name and address:
8. In addition to himself, Owners designates the following person(s) to receive a copy of the Lienor's Notice as provided
in Section 713.13(1)(b), Florida Statutes.
Name and address:
9. Expiration date of this Notice of Commencement: (the expiration date is 1 year from the date of recording unless a
different date is specified)
Alt
Signature of Owner
Print Owner's Name
•
U 5 v,
uJ
Sworn to and subscribed before me this (1) day of
Notary Public
Print Notary's Name
My commission expires:
123.D1 -32 PAGE 4 8102
, 2O .
Prepared by ,„---- ''S 64,0,(74.
Address: .:,:_267? .4)(+6 13
01-1/11-1)(-1-1A
�3LJ`<�5 •I
1
1
High Velocity Hurricane Zone Uniform Roofing Permit Application Form
MIAMI -DADE COUNTY BUILDING DEPARTMENT ELECTRONIC APPLICATION
Master Permit No.
Contractor's Name:
Section A (General Information)
Process No.
1 Ce emi9t Y
Job Address:
I 81,7 y /U E / D0
Roof Category ,
✓ Low Slope E Mechanically Fastened Tile M7 ortar /Adhesive Set Tile
✓ Asphaltic Shingles r Metal Panel/Shingles r Wood Shingles/Shakes
E Prescriptive BUR- i S 150 r Other:1
® is 1 41
Roof Type
New Roof r :Roofing r Recovering r Repair IT Maintenance
tacks located on the roof? r Yes 1- 12‘ If yes, what type? r Natural r LPGX
Roof System Information
Low slope roof area (ft.a) l Steep Sloped area (ft.') I .g-5O 6 Total (ft.2)1 g'
$bt)
Section B (Roof Plan)
Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions
of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets.
Perimeter Width (a'):1 3 Corner Size (a' x a'): 3X '
MME■■■■■■■■■■■■■■■■■ ■11■■■■■■■ ■■■■■■■■■ ■■■ ■11■■■■ ■ ■■ =
MMMM■ ■• ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■■■■■■■ ■1111■■■■■■■■■■■■■■■ ■11■■■■ MUM
■1■ ■ ■ ■■■ ■ ■ ■ ■ ■ ■■■ ■ ■ ■■ 1111■■■■■■■■■■■■■■■ ■1111■ ■11■�■�■ ■11■■
•1 ■IIIIIIIIIIIE 911111 "' I111111111:11111111_11111
MMOMMEMMENEMMING IsM V i■■■■ ■■■■■ ■■ ■■■■■M� ■■111111■
■■■ ■IM■■■■■11■■■n■ qtr► Sri■ MINX■■ ■■■MAR■■■■■■■■■■■■■ ■ ■■■■■
MME■MII■■■■■■■■ 'Ii■6 MAIM■ rt i■ M .■■■■MMONki■■■■■■■■■li■■■ ■■■■■
MEM■MM■ ■■■■■■MLI i■ Y■ O> t, Wl> M■ 11M \1111MlN!<I■ ■■■11 ■ ■ ■ ■ ■■ ■■11■ 11■■■M
MOMMEMMEMMEMEMMEMMEMMMAINIMMUMMOUNIMMOMMIMMEMMOIM i11■I■■MMUM
MMM111■11■■ ■■■■ ■■■■I :61=M■■■■■11■■■■M■■ ■■■■■■11■■■■■ ■■■ ■■■■■
■ME■MI■■■ ■■■■■■rnV■■■■■MEMPWAH ■■■■■■■■■■■■■■■ ■■■■■
M111■M111■■■■■■■■■Ii11\ ■■11 ■11■i►\GE ■11Wq /i ■ 1111■• ■ ■ ■ ■ ■■.■■■ ■■■■■
MMINIMMOMEMMEMMEMINIMMOMMEMEMSP22111111MMEMMEMMIMMEM ■■■■■
■■■■■■■■■■■■■u i■■■■rmaimmir •m■■■■■■■■■■■■■ ■■■■■
MM■■■■■■■■■■11Mii■■i . i■■r11!1■NrY■■■M ■■11■■■■■■11■11■■11r.M■�■■■■■■
U 111111111111��11�11111 =1i... i••••••u•••••iii�iiiii
■■■■■■■■■■■■■■ I■■ n11■■■ ■■.■ ■■■■.•■■ ■■■■■ ■11 ■11■■IIr11111
M■■■■■■■■■■■■■■ a ■■iI■ ■r■ ■■■■r ■■ ■ ■■�■■■■11■■■■■■■
111111111111111111111111111111111111111111111 i ■onnii
I VAN Goi RA 1401-C. ° 1
Roof System Manufacturer:
Section D Sloped System Description
Tile Roof System
JLIFE TILE -- /VI 0A// tis •
Notice of Acceptance Number (NOA):�� /
Minimum Design Wind Pressures, If Applicable (from RAS 127 or Calculations):
P1:
P 2:
P 3:
OCT. r& ZWM
Et O 7 201
Maximum Design Wind Pressures, (From the NOA Specific system): psf
Fill in the specific roof assembly components. if a component is not required, Insert not applicable (n/a) in the text box.
Roof Slope:
"/12"
Roof Mean`Height: ft.
Method of Tile Attachment:
I — Adhesive, OEM.1, ; eddy Polyfoam Polypro-
Alternate Method of Tile Attachment per NOA:
IN/A
Drip Edge Size & Gauge:
Drip Edge Material Type:
Drip Edge Fastener Type:
I - -3° face 24 ga.--
I— Galvinlzed Metal-
11/4 R.S Nails 4" O/C
Hook Strip/Cleat gauge or weight
I --n/a-
Deck Type:
I- 1 °xS °T &G-
Optional Insulation:
Optional Naiiable Substrate:
Optional Nailable Substrate ttac4iment • •
j
IN/A
Tile Underlayment (Cap Sheet) Type:
•
• •
• •
• •
•
•
•
••••••
• •
• •• • •
•
••••
Tile Underlayment Attachment Method:
A5HPRL,T - ,B/ic// N,4/4 - , a t -
Tile Profile:
el�tifi u'd m
Miami Shores Village
APPROVED
BY
DATE
ZONING DEPT
•
BLDG DEPT
•.
SUBJECT TO COMPLIANCE WITH ALL FEDF�
STATE AND COUNTY RULES AND RE(
MEA/ PA )`
Florida Building Code Edition 2002
h Vel Hurricane Zone Uniform Permit • • cation Form.
Section E (Tile Calculations)
For Moment based tile systems, choose either Method 1 or 2. Compared the values
for Mrwith the valves from M1. If the Mt values are greater than or equal to the Mr
values, for each area of the root, then the tile attachment method is acceptable.
Method 1 "Moment Based Tile Calculations Per RAS 127" z
(PI: 1/5 z A. O b'i. m 1 3 Mg: _CV? V 7 = Mir 7° e'Y NOA Mt 'lY
(P2:7» 269 ® 2 'r3 -Mg: 697 =Mrz_L" NOAMf E%°
(P3:y an' z ?O e2 = 33- ) —Mg: T ;7) =Mr.3 7"Cr NOA Mt 2/C
Method 2 "Simplified Tile Calculation Per Table Below"
Required Moment of Resistance (Mr) From Table Below NOA Mt
Mr Required Moment Resistance*
Roof Height
15'
20'
25'
30'
40'
—
Roof
Slope i
2:12
34.4
36.5
38.2
39.7
422
3:12
32.2
34A
36.0
37.4
39.8
; ..R4
t12
304
32.2
33.8
35.1
5:12
28.4
30.1
31.6
• • • 82
• . 34.9
•
6:12
264
28.0
294
••• P
•••••
7:12
244
259
27.1
• ••2141
i0.0
••••
*Must be used in conjunction with a list of moment based tile systems endorsddo by the
Broward County Board of Rules and Appeals. • •
•• ••
For Uplift based tile systems use Method 3. Compared the values for r i the
values for Fr. If the F' values are greater than or equal to the Fr value/, for each
area-of the roof, then the tale • attachment method is acceptable. • •' •
••••
• •
••••
••• •
• •
••
•
••••
••••
• ••
• • •
Method 3 "Uplift Based Tile Calculations Per RAS 127"
(Pi: z1: x w:= ) —W: z cos B: = Fr,: NOAF'
(P2: al: = x w: ) —W: acos 9 :_= Frz: NOAF
(P3: z1: = z w: = ) —W: cos 0: = Fr3: NOAF'
• •
•
• •
• •
•
•
•
• •
• •
Where to Obtain Information
Description
Symbol
Where to find
Design Pressure
P1 or P2 or P3
RAS 127 Table 1 or by an engineering analysis prepared by PE based on ASCE
7
Mean Roof Height
H
Job Site
Roof Slope
g
Job Site
Aerodynamic Multiplier
a.
NOA
Restoring Moment due to Gtavity
MR
NOA
Attachment Resistance
Mr
NOA
Required Moment Resistance
1Vk
Calculated
Minimum Attachment ftedstance
F
NOA
Required Uplift Resistance
Fr
Calculated
Average Tile Weight
W
NOA
Tile Dimensions
1= length NOA
w= width
All calculations must be submitted to the Building Official at the time ofpermitapplicadon.
123_01-48 5/03 PAGE 5
MIA MIDADE
BUILDING CODE COMPLIANCE OFFICE (ECCO)
PRODUCT CONTROL DIVISION
NOTICE OF ACCEPTANCE (NOA)
Monier Lifetile, LLC
200 Story Road
Lake Wales, FL 33898
MIAMI -DADS COUNTY, FLORIDA
METRO -DADE FLAGLER BUILDING
140 WEST FLAGLER STREET, SUITE 1603
MIAMI, FLORIDA 33130 -1563
(305) 375 -2901 FAX (305) 375-2908
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials.
The documentation submitted has been reviewed by Miami -Dade County Product Control Division and accepted
by the Board of Rules and Appeals (BORA) to be used in Miami Dade County and other areas where allowed by
the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami Dade County Product Control
Division (In Miami Dade County) and /or the AHJ (in areas other than Miami Dade County) reserve the right to
have this product or material tested for quality assurance purposes. If this product or material fails to perform in
the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately
revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right
to revoke this acceptance, if it is determined by Miami -Dade County Product Control glivi�ieip that this product or•
material fails to meet the requirements of the applicable building code. • • • • • • • • •
•
• This product is approved as described herein, and has been designed to comply with the lgi.da BuilddiCode
•
including the High Velocity Hurricane Zone of the Florida Building Code. •
DESCRIPTION: Vanguard Roll Concrete Roof Tile • • • •
• •
••
• •
• •
LABELING: Each unit shall bear a permanent label with the manufacturer's name or jogd, cry, statr,,i
following statement: "Miami -Dade County Product Control Approved ", unless otherwise Hated herein.... • •
RENEWAL of this NOA shall be considered after a renewal application has been filed a3ad there 114s lt no
change in the applicable building code negatively affecting the performance of this product. • • • •
•
•
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or c1 arige in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any
product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failurf: to t brnply
with any section of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and follbwed by
the expiration date may be displayed in advertising literature. If any portion of the N4:)A is cisplayed, then it shall
be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacture, or its distributors '.
and shall be available for inspection at the job site at the request of the Building Official.
This NOA consists of pages 1 through 7.
The submitted documentation was reviewed by Alex Tigera,
NOA No.: 074023.07
Expiration Date: 12/16/12
Approval Date: 12/20/07
Page 1 of 7
•
•
•
•
•
ROOFING ASSEMBLY APPROVAL
Category:
Sub- Category:
Material:
Roofing
Low Profile Roofing Tiles
Concrete
1. SCOPE
This renews a system using Monier Lifetile Vanguard Roll Concrete Roof Tile, as
manufactured Monier Lifetile LLC in Pompano Beach, FL. and described in Section ,2 of this
Notice of Acceptance. For locations where the pressure requirements, as determined by
applicable Building Code does not exceed the design pressure values obtained by calculations in
compliance with RAS 127 using the values listed in section 4 herein. The attachment calculations
shall be done as a moment based system.
2. PRODUCT DESCRIPTION
Manufactured by
Applicant Dimensions
Mother Lifetile LLC
Vanguard Roll Tile
Trim Pieces
1 = 16 -1/2"
w = 13"
1 /s" thick
1= varies
w = varies
varying thickness
2.1 SUBMITTED EVIDENCE:
Test Agency
Redland Technologies
Redland Technologies
Redland Technologies
The Center for Applied
Engineering, Inc.
The Center for Applied
Engineering, Inc.
Redland Technologies
Test
Specifications
TAS 112
TAS 112
Test Identifier
7161 -03
Appendix i1I
7161 -03
Appendix 11
P0402
94 -060B
94-084
P0631 -01
Product
Description
Low profile, interlocking, high pressure
extruded concrete roof tile equipped with one
nail hole and double roil rib: For disci desk
or battened nail -on, mortg tr tdhesiv . § fit•
applications. •••••• •
Accessory trim, concretemti pieces for use
at hips, rakes, ridges arll•"al.lej termination.
Manufactured for each tfi8 I ?ofile. • • • •
• •
.. ..
• • •
• •
Test Name/Report i • • •
.. •
Static Uplift Testing
PA 102 & PA 102(A) .
Wind Tunnel Testing
PA 108 (Nail -On)
Withdrawal Resistance Testing of
screw vs. smooth shank nails -
Static Uplift Testing
PA 101 (Adhesive Set)
Static Uplift Testing
PA 101 (Mortar Set)
Wind Tunnel Testing
PA 108 (Mortar Set)
.. • •
• •
•
..••
in.tt....
•,.•.•
Dec ..4611
Dec. 1991
Sept. 1993 -
March, 1994
May 1994
July 1994
NOA No.: 07-1023.07
Expiration Date: 12/16/12
Approval Date: 12/20/07
Page 2 of 7
Tess. Agency
Redland Technologies
The Center for Applied
Engineering, Inc.
The Center for Applied
Engineering, Inc.
The Center for Applied
Engineering, Inc.
The Center for Applied
Engineering, Inc.
Celotex Corporation
Testing Services
Walker Engineering, Inc.
Walker Engineering, Inc.
Walker Engineering, Inc.
Walker Engineering, Inc.
Walker Engineering, Inc.
Walker Engineering, Inc.
Walker Engineering, Inc.
Nutting Engineering
Test identifier
Letter Dated Aug. 1,
1994
Project No. 307025
Test #MDC -76
25- 7183 -1
25- 7183 -2
25- 7214 -2
25- 7214 -6
528454 -2 -1
520109 -2
Calculations
Evaluation Calculations
Evaluation Calculations
Evaluation Calculations
Evaluation Calculations
Evaluation Calculations
Evaluation Calculations
TAS -112
Test. Name/Report.
Wind Tunnel Testing
PA 108 (Nail -On)
Wind Driven Rain
PA 100
Static Uplift Testing
PA 102
(2 Quik -Drive Screws, Direct
• Deck)
Static Uplift Testing
PA 102
(2 Quik -Drive Screws, Battens)
Static Uplift Testing
PA 102
(1 Quik -Drive Screw, Direct Deck)
(1 Quik -Drive Screw, Battens)
Static Uplift Testing
PA 101
Aerodynamic Multiplier
25 -7183
25 -7094
25 -7496
25 -7584
25- 7804b -8
25- 7804 -4 & 5
25- 7848 -6
• •
• •
•.
•
•
....
..•.
Date
Aug. 1994
Oct. 1994
Feb. 1995
Feb. 1995
March, 1995
Sep. 1998
Dec. 1998
August 2007
MaroV
•
Febru4:1: 6
April 1996
Decelliel•
1•9b •
••
•
•• .•
• • •
Aerodynamic Multiplies
• , • Octabv� 7
i • • •
Two Patty Adhesive Set Sys'Cm. • Apt; 19w
13343.1 - June`2&f%
�..
NOA No.: 07- 1023.07
Expiration Date: 12/16/12
Approval Date: 12 /20/07
Page 3 of 7
3. LIMITATIONS
3.1 Fire classification is not part of this acceptance.
3.2 For mortar or adhesive set tile applications, a static field uplift test shall be performed in
accordance with RAS 106.
3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform
quarterly test in accordance with TAS 112, appendix `A'. Such testing shall be submitted to
the Building Code Compliance Office for review.
3.4 Minimum unde5rlayment shall be in compliance with the applicable Roofing Applications
Standards listed section 4.1 herein.
3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope
unless stated otherwise by the underlayment material manufacturers published literature.
3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in
compliance with applicable building code.
4. INSTALLATION
4.1 Monier Lifetile Vanguard Roll Concrete Roof Tile and its components shall be installed in
strict compliance with Roofing Application Standard RAS 118, RAS 119, and RAS 120.
4.2 Data For Attachment Calculations
•
Table 1: Average Weight (W) and Dimensions (1 x w) • • •
••
•
Tile Profile
Weight W (lbf)
Length -1(ft) •
Monier Lifetile Vanguard Roll
Tile
9.2
1.38
•.Width -04,V .•
•
•••• 1.08■•••
• •
.••• ••••
• •
•• ••
••• •
• •
••
Table 2: Aerodynamic Multipliers - X (ft3) • •
X t • �X,'(fta) ••••••
Batten Application Direct pe* App nation
0266 0.289 • • • •
Tile
Profile
Monier Lifetile Vanguard Roll Tile
•
•
•
• •
• •
•
•
•
• •
• •
Tile
Profile
Monier
Lifetile
Vanguard
Roll Tile
2 ":12"
Table 3: Restorin
3 ":12"
Moments due to Gravi M
4 ":12"
5 ":12"
ft-11:1‘
Battens
5.30
Direct
Deck
Battens
Direct
Deck
Battens
Direct
Deck
Battens
Direct
Deck
Battens Direct
Deck
6.03 5.24 5.97 5.16
5.87 5.05 5.75
7 ":12" or
greater
Direct
DOCK
4.92 t 5.60 4.78 5.44
Batttanfi
NOA No.: 07- 1023.07
Expiration Date: 12/16/12
Approval Date: 12/20/07
Page 4 of 7
Table 4: Attachment Resistance
Expressed as a Moment - M, (ft-Ibf)
for Nail -On Systems
Tile
Profile
Fastener Type
Direct Deck
(min 15/32"
plywood)
Direct Deck
(min. 19/32"
plywood)
Battens
Monier Ufetile
Vanguard Roll
Tile
2 -10d Ring Shank Nails
27.8
37.4
28.8
1 -10d Smooth or Screw
Shank Nail
8.8
11.8
4.1
2 -10d Smooth or Screw
Shank Nails
16.4
21.9
7.1
1 #8 Screw
_
25.8
25.8
22.9
2 #8 Screw
47.1
47.1
49.1
1 -10d Smooth or Screw
Shank Nail (Field Clip)
24.3
24.3
24.2
1 -10d Smooth or Screw
Shank Nail (Eave Clip)
19.0
19.0
22.1
2 -10d Smooth or Screw
Shank Nails (Field Clip)
35.5
35.5
34.8
2-10d Smooth or Screw
Shank Nails (Eave Clip)
31.9
31.9
32.2
0 - -
•
••
•.••
. •
••.•
Table 6: Attachment Resistance Expressed as a Moment4M1' R•Ibf) •
for Two Patty Adhesive Set Systems . " ". .•••• .
Tile
Profile
Tile Application
•.•••
Minimum Attadllftfbnt
• • • Resistance • •
••
26.13 •
• • ••••
Monier Ufetile Vanguard Roll Tile
Adhesive
1 See manufactures com.onent a.. royal for installation re•uirements. •
•••
2 Flexible Products Company TileBond Average weight per patty 11.4 grams. •. • • • •
Polyfoam Product, Inc. Average weight per patty 8 grams. '.�.y -'-
Table 7: Attachment Resistance Expressed as a Moment - rrtr (:t -ibf)
for Sin • le Pa Adhesive Set S stems
Tile
Profile
Tile Application
Mini:num Attachment
, Resistance,.
Monier Lifetile Vanguard
Roll Tile
Polyfoam PolyProTM
86.61
Polyfoam P0IyPr0TM
45.56
.
3 Large paddy placement of 54grams of PoIyProTM.
5 Medium paddy placement
of 24grams of PolyProTM.
NOA No.: 07- 1023.07
Expiration Date: 12 /16/12
Approval Date: 12/20/07
Page 5 of 7
Table 8: Attachment Resistance Expressed as a Moment - Mi (ft-Ibf)
for Mortar Set Systems
Tile
Profile
Tile
A. • lication
Attachment
Resistance
Monier Lifetile Vanguard Roll Tiie
Mortar Set'
20.60
5. LABELING
All tiles shall bear the imprint or identifiable marking of the manufacturer's naive or logo as
shown below, dr following statement: "Miami -Dade County Product Control Approved '.
VANGUARD ROLL
MONIERLIFETILE LLC, VANGUARD ROLL TILE IDENTIFICATION MARK
(POMPANO, FL PLANT) •
• • •
LOCATED UNDERNEATH TILE •.. • •
• • •
• .••
•
6. BUILDING PERMIT REQUIREMENTS • •
6.1 Application for building permit shall be accompanied by copies 8f #l�fbllowiig0• „• • •
6.1.1 This Notice of Acceptance. . • • •
6.1.2 Any other documents required by the Building Official dr•ap}icable buildi4
code in order to properly evaluate the installation of thissyS •
• •::.
o.•
• • •0••
• • •
•`o` •' • •i
• ,• •
••••
NOA No.: 07.1023.07
Expiration Date: 12/16/12
Approval Date: 12120/07
Page 6 of 7
•
•
•
• •
••••••
• •
PROFILE DRAWING
•
• •
•
• • •
•••• 0000 .
• •
••••
•• ••
• • •
•
MONIER LIFETILE VANGUARD ROLL CONCRETE ROOF TICE • •
END OF THIS ACCEPTANCE
••••
••• •
••
••
• •
••••
• ••,
• • •
NOA No.: 07- 1023.07
Expiration Date: 12/16/12
Approval Date: 12/20/07
Page7of7
•
• •
•
•