FW-09-1049Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Inspection Number: INSP - 117516 Scheduled Inspection Date: August 11, 2009 Inspector: Rodriguez, Jorge Owner: OLIVEIRA, LOIS Permit Number: FW -6 -09 -1049 Job Address: 1270 NE 100 Street Miami Shores, FL Project: <NONE> Contractor: HOME OWNER Permit Type: Fence/Wall Inspection Type: Final Work Classification: Wire Fence Phone Number Parcel Number 1132050090030 Building Department Comments CHAIN LINK FENCE WITH GATES ON SIDES OF THE HOUSE. REPLACE ALONG BACK WITH 4' CHAIN LINK 53 FEET LONG. Passed Failed Correction Needed Re- Inspection Fee No Additional Inspections can be scheduled until re- inspection fee is paid. Inspector Comments A 1 1 1 7nne For Inspections please call: (305)762 -4949 Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores,: Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 BUILDING PERMIT APPLICATION FBC 2004 Permit Type (circle): Building Owner's Name (Fee Simple Titleholder) Owner's Address 1 71) A' ° Cit / 177 ' e .2.5 State Roofin z.."/ 3 S .4e.e Z)Z- / Phone # Zip 33 /32 Permit No. JUN 2 2, 2009 Master Permit No. Tenant/Lessee Name Phone # Job Address (where the work is being done) City Miami Shores Village County Miami -Dade FOLIO / PARCEL # Zip 3 J / 3 g Is Building Historically Designated YES Contractor's Company Name Contractor's Address NO /14 Adja c o.) City State Phone #r 5-4'-7 3 Zip Qualifier Name Phone # State Certificate or Registration No. Certificate of Competency No. Architect/Engineer's Name (if applicable) Value of Work For this Permit $ Y-)0 OD Phone # Square / Linear Footage Of Work: 121 / Type of Work: ❑Addition ❑Alteration ,New Describe Work r 4'' /'d7 a/ih5 "71/ �Ul� ❑ Repair/Replace ❑ Demolition **************************Fees********* ]� Submittal Fee $ V • 00 Permit Fee $ /Doe= 0-g O Notary $ Training/Education Fee $ Scanning $ I Radon $ Bond $ Code Enforcement $ Structural Review. $ ** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** CCF $ 040 C Technology Fee $ DPBR $ Zoning $ Double Fee $ Total Fee Now Due $ 4'50 See Reverse side —4 Bonding Company's Name (if applicable) Bonding Company's Address City r State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for FI.FCTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature �� Signature Owner or Agent The for oin�gninstrument was acknowledg befo a me this O'�`�-• The foregoing instrument was acknowledged before me this day of �� ,20 byGOIS �1 V .. , day of ,20_,by who i personally own to me or who has produced / who is personally known to me or who has produced Wantification and who did take an oath. as identification and who did take an oath. Contractor NOT Sign: Print: Y PUBLIC: (12)0,&614 My Commission Expires: ** * * * * * ** * * * * * ** * * * * * * * * * * * * * * * ** APPLICATION APPROVED BY: (Revised 07/10/07) NOTARY PUBLIC: 4' �'N� Cvgv's ,- Sign: Gc "R # *��,, Print:. • �p�3. c �1 My Commission Expires: * * * * * ** ****** *** * * ******* :** ***** ***** ***+x:x***** * ** *****:x*** ** Plans Examiner Engineer Zoning VILLAGE OF MIAMI SHORES OWNER BUILDER DISCLOSURE STATEMENT NAME: ®l am®-- i2 / 2) ✓ DATE: � �-�' %7 ADDRESS: /c 7I Do hereby petition the Village of Miami Shores to act as my own contractor pursuant to the laws of the State of Florida, F.S 489.103(7). And I have read and understood the following disclosure statement, which entitles me to work as my own contractor; I further understand that I as the owner must appear in person to complete all applications. State Law requires construction to be done by a Licensed contractor. You have applied for a permit under an exception to the law. The exemption allows you, as the owner of your property, to act as your own contractor even though you do not have a license. You must supervise the construction yourself. You may build or improve a one - family or two - family retidence. You may also build or improve a commercial building at a cost of $25,000.00 or less. The building must be for your own use and occupancy. It may not be built for sale= lease. If you sell or lease a building you have built yourself within one year after the construction is complete, the law will presume that you built for sale or lease, which is a violation of this exemption. You tray not hire an unlicensed person as it contractor. It is your responsibility to make sure the people employed by you have licenses required by state law.and by county er municipal licensing ordinances. Any person working on your building who is not licensed must work under your supervision and must be employed by you, which means that you must deduct F.LC.A and with - holdings tax and provide workers' compensation for that employee, all as prescribed by law. Your construction must comply with all applicable laws, ordinances, .buildings codes and zoning regulations. Please read and initial each paragraph. 1. I hold title to the above property and I am planning on doing this construction Myself. Initial 2. I understand that as an owner- builder I must abide by all zoning ordinances and building regulations in effect at the time of permit application. Inactive permits for a period of over 180 days will become null and void (expired) and a new permit will be required. to be issued for reinstatement of the permit. Initial LAS 3. I have an understanding of the 2004 FBC & FRC and understand that this ,department and its inspectors are there to help enforce and interpret the code. There is a copy of the code in this office for review. Initial L/3 47 4. I understand that the building official and inspectors are not there to design, alter or give advice on how to meet code — only if the structure meets the minimum code. Initial z_.,6 D 5. I understand that as an owner - builder, that any contractor disputes with sub- contractors and myself must be handled in a civil court with the advice of au attorney. The department will not mitigate any contract disputes. Initial 0 6. I understand that if I compensate any person or company for work performed they are required to have a business license in the county. If for any reason they do not posses a business license I will be responsible and liable for any wrong doing from this unlicensed company or person. Initial L .� 7. I understand that if any person gets injured on my construction project—they are entitled to workmen's compensation. And if they do not posses a workmen's policy I could be held liable for all doctor and related cost which could include loss of wages during recovery from injury. Initial 8. I understand that under state and local laws I can not do . any Electrical, Plumbing, Heating, Air & Roof work on my property with out first obtaining the proper permits by licensed contractors. Initial Was acknowledged before me this goc, day of , 2009 By CATS 2?JJ L 1 if tf)v ) who was personally known to me or who has Produced there License or identification. Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL 33138-0000 Phone: (305)795-2204 Fax: (305)756-8972 Permit NO. FW-6-09-1049 Issue Date: Not Issued Expires:Not issued Folio Numberl 132050090030 1 Owner's Name: LOIS OLIVEIRA Owner's Phone: t... Job Address: 1270 100 Street Total Square Feet: 53 Miami Shores, FL Total Job Valuation: Contractor(s) Phone Primary Contractor Planning and Zoning Criteria and Comments Approved: Yes Comments: Date Approved: 6/29/2009 : Yes . O JUN 2 2 2009 BY:_e _e_e_eme� T 0.2' .3 P • ac,LOT . )0,0 M� -f r Q � 3/4' g.1 crs a2' 2c= h BLOCK -1 c 4 'BLOCK-1 2 3/4" IP BLOCK -1 14 4' 119 _eancn hnk .374• 75.00' (F'% %) 25.00' ces emu. BLOCK-1 BLOCK -1 15 16 Q ®13 1-n0 '7 ,tom AWED Miami Shores Village B DG DEPT TO COMPLIANCE WITH ALL FEDERAL COUNTY RULES AND REGULATIONS CHAIN LINK FENCE DESIGN DETAI.E;;;. N.T.S. • • Notice to Properties with Pools: If the fence is to meet the criteria as a pool barrier, the fence shall not be climbable and all rails must be placed facing the inside of the property. Pedestrian gates shall have self- closing and latching devices installed at a minimum of 54" above ground. For further details see Section 424 of FBC. (ACCORDING TO THE F.B.C. SECTION 2224) 10'- 0" o.c. Max. •• • 00.41 • • • 0• • • • flic • • • • • • •• •0• • •• V • • • • •••• V ••0• vr•- • ♦i♦i♦•• •∎ ♦i ♦i♦i♦iiA st i♦i♦i♦o ♦i ♦i ♦: ♦4: i♦, 4 ♦>♦• ♦•♦i♦i♦i °i♦i♦i♦i♦i t , •• ♦ ♦ ♦ ♦ ♦♦ ♦♦ ♦ ♦♦ ♦♦ ♦ ♦ ♦ ♦♦ ♦ ♦ ♦ ♦ ♦♦ ♦ ♦ ♦♦ ♦♦ ♦ i ♦ ♦ ♦♦ ♦ ♦ ♦ ♦♦ ♦♦ ♦♦ ♦ ♦ ♦ ♦ ♦ ♦♦ > i . ♦ ♦ . ♦ ♦ ♦ ♦ ♦ • v♦' ' `♦ ♦ ♦ ♦ ♦ ♦ ♦♦ •♦•♦•♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦ ♦ ♦ ♦♦♦♦♦♦♦♦ ♦ ♦ ♦♦♦♦ ♦♦♦♦ ♦ ♦ ♦♦ ♦ ♦ ♦♦ ♦ ♦• • •.♦♦ ♦ ♦• • k. *tiA .... ♦O V ♦♦♦♦♦♦♦♦ i S♦♦♦♦♦♦♦♦♦ ♦♦ ♦♦ ♦ ♦ ♦♦ ♦ ♦♦i♦ ♦♦i ♦ ♦ ♦ ♦♦ ♦♦ ♦ ♦♦ ♦ ♦♦i, 4, ♦ i ♦♦ ♦♦ ♦ ♦♦♦. ♦'' ♦ ♦♦♦i ♦ ♦♦s♦os •♦♦♦♦♦♦♦♦♦♦♦♦♦♦•♦•♦•♦♦♦♦♦•♦•♦•♦♦♦•♦♦ ♦♦ ♦• ♦♦ ♦♦ ♦♦ ♦ ♦ ♦♦ ♦ ♦ ♦ ♦O4siO ♦�' ♦♦ ♦♦. „4.17./4 ♦ ♦ ♦ ♦ ♦ ♦, f♦♦ • •• • • • 4141 • • •• • • • 4141 ♦ ♦ �♦ • • ♦ ♦♦ • $ ♦•♦♦ ♦♦ ♦.♦ ♦♦ ♦ ♦♦ ♦♦ ♦♦ ♦♦ ♦ ♦' ♦♦ ♦.� ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦.♦ i ♦ °♦ • ♦ ♦ ♦ • ♦ ♦♦ •♦ c♦ ♦ • • ♦ ♦ • ♦ 4141 ♦• •♦ ♦ ♦•♦ ♦ • ♦ ♦♦ • ♦• 4141••♦ • • ♦• 4141 • •♦ •i ♦ i♦ i ♦ i ♦ i ♦ i ♦ i i ♦ i ♦ i ♦ i ♦ i♦ ii• i ♦i • i • ♦♦ ♦ . ♦ •♦ ••••••••••••••••• � ♦ � •••• � • • ■• •• •• •• •• •• •• •• •• •• •• •�• •• • •••••••••••••• ,• • ♦♦ ♦•• ♦•• ♦♦ ♦••i ♦ ♦ ♦i♦4141 ♦• ♦♦ ♦4141♦ ♦4141••• ■ j ► i• ♦•♦��♦•••••� �M�♦♦ •♦ i ••••••••••• 41••♦♦♦♦ ♦• •••••• •••••• • ♦♦♦♦♦ ■♦ ♦♦♦ ♦♦♦♦♦♦♦♦♦♦♦♦♦♦ ♦♦♦ ♦♦♦♦41••41♦♦• • • •• v► ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦O ♦ ♦• ♦O• ♦ ♦♦ ♦ ♦ ♦ ♦ ♦ ♦ ••••••••••• •• �e♦♦•♦♦♦•♦♦♦•♦♦♦♦♦♦♦•♦•♦♦ ♦ ♦♦ ♦♦ ••••••••••••• •••••••••• 4141 s,:. ❖. ♦.♦.,& J 0, ,•••4,1 ♦• ♦•♦lei• ♦•e♦• ♦• ♦• ♦•••i•ci ••♦ ♦0e•••e•i•♦• •••••P••••••••••••• o••• •••••••• ©•••••••••••••••• •••••• ••••• ••••••••••••••••••••••• • • • General Notes: 1. This table is applicable only to fences with unrestricted airflow. 2. Fabric: 12 -1/2 gage minimum. 3. Tension Bands: Use one less than the height of the fence In feet evenly spaced. 4. Fabric ties: Must be minimum the same gage of the fabric. 5. Fabric Tie Sparing on the Top Rail: Five ties between posts, evenly spaced. 6. Fabric Tie Spacing on Line Posts: One less than height of the : fence in feet, evenly spaced. 7. Either top rail or top tension wire shall be used. 8. Braces must be used at Terminal Post if top tension wire is used instead of Top Rail. 9. In order to follow the contour of the land, the bottom of the fence may dear the contour of the grdund by up to 5 inch without increasing 'table values to the n-x hi .h r m't ChatnLinkFenneFDC 7'^ See Table Below ••••••♦ •♦♦ • •♦ •••• •♦ •••••••••••• • • • • • • • • • • • • •k••••••••••♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦ ♦w••♦♦♦♦♦♦♦♦♦♦♦♦ V ►• ♦ ■• ♦• ♦ •♦ • • ♦ • • • • ♦• ♦• ♦•♦ ♦ • ♦ • ♦ • ♦• ♦ • ♦ • ♦ • ♦ • ♦• ♦ • ♦ • ♦ • • . r • ♦ ••••• ••••••• • ♦ • ♦ k$•••••••••♦•• • • • •■♦• • • •♦ ♦ •■ v���������V•• •••••••• •••••••••••••••J• • • •• •••••••••••♦♦ • ♦ • • • •�♦ ♦ ••i ♦i•i•i•i•i ♦i•i•♦i•i iiiii4� - - -- - --♦ ---• ••••••soi• •••••••• ♦ •• • • •••••••••••••�•••• i••i •ii•i••••••••••••••••••••••••••i •••*••••••••••0 •••••i••••••••• e• •• •• •••• ••••%%••••% % % % •• % %• % %• •• •• % %i:•i• A %%••% •••••• % i • i ��i• ••••••i •i••••i ••••h i •l •l •i�•i •i •i••••i •i•i •i i•i ••Vr••••i •ii •i •i•O•i •i •i• v a v VV N" V V A V V • t. ..::1 cc :,-..2?" _—L, See Table i Below • • Fence Height Upto4' Over 4' to 5' Over 5' to 6' Over 6' to 8' Terminal Post Size & Thick 2 -3/8" x 0:042 2-3/8" x 0.042 Terminal Post Footing 2 -3/8" x 0.042 2 -3/8" x 0.110 10 "' x 24" 10" x 24" 10 "x24" Line Post Size & Thick 1 -5/8" °x 0.047 1 -7/8" x 0.055 Line Post Footing 8" x 24" 10" x 24" 1 -7/8" x 0.065 2 -3/8" x 0.095 Over 8' to 10' Over 10' to 12' Over 12' 2 -7/8" x 0.110 12" x 40" 2 -3/8" x 0.130 8" x 24" 8" x 24" 10" x 36" —10 "X4,0" 2 -7/8" x 0.160 12" x 42" 2 -7/8" x 0.12.0 12" x 42" Section 2224.1 FBC:•Fences over 12' height shall be designed according to the loads specified in Chapter 16 (HVHZ). Cy r0,u/ oe ..;i g I 0