RF-08-1387Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Inspection Date: 10/02/2008 Inspector: Bruhn, Norman Owner: BAILEY, JAMES Job Address: 1100 99 Street NE Miami Shores Village, FL 33138- Project: <NONE> Permit Type: Roof Inspection Type: Final Roof Um,.Work Classification: Roof - New Block: Contractor: OBENOUR ROOFING SHEET METAL & SUPPLY CO. INC Phone Number Parcel Number 1132050180150 Lot: Phone: 305 - 757 -2612 Building Department Comments TEAR OFF EXISTING ROOF. INSTALL ALTUSA CLAY S BLEND 60% TERRACOTA, 20% PEACH, 20% BROWN TILE ROOF. INSTALL GAV 4.4 MODIFIED ROOF SYSTEM ON FLAT ROOF. COLOR THRU, NO GAS VENTS 0 0 0 Passed a gaes (4 Inspector Comments cc ,.--a Failed Correction Needed Re- Inspection Fee ($75) No Additional Inspections can be scheduled re- inspection fee is paid. until Thursday, October 2, 2008 Page 1 of 2 JL. FLORIDA INTERNATIONAL ENGINEERING & TESTING LAB INSIGHT• INNOVATION• INTEGRATION No 1591 16701 Southwest 117th Avenue • Miami, Florida 33177 Phone: (305) 378 -1991 • Fax: (305) 378 -1997 ON -SITE CONCENTRATED UPLIFT LOAD TESTING OF ROOF TILE IN FULL ACCORDANCE WITH MIAMI -DADE BUILDING CODE COMPLIANCE PROTOCOL TAS 106 SITE SPECIFIC INFORMATION Owner's Name: 1 k kf Job Address: It ®t' I4 9 cl 61,1 `"SAO,1.4 i c?s:.> 4 C-1, Roofing Contractor: o Fv N Type of Tile: AtT 0� k '� to i" Date Installed 9 —22 - Approximate Roof Height: 17 feet 't-ra .- 3 :12 Type of Access to Roof: Scaffolds .. Ladder Other Approximate Square Footage of Roof: , 0019 ft2 Required Testing Force: 35 lbs. Testing Equipment: F.G.E. 100X, Shimpo Instrument Date: 1 ,-2,4 -06 Permit # 1W1 -0E5- TEST RESULTS P = PASS, F = FAIL Test Location Up IIft Pail Test (P or 9 Test Location Uplift Pull Test (P or F) Test Location Uplift Pull Test (P or 9 Test Location Uplift Pull Test (P or F) 1 A,SAV- 0 26 456 V,. P 51 46..6 .® 76 2 ` 27 52 77 3 28 53 78 4 29 54 79 5 30 55 80 6 31 55 81 7 32 57 S2 8 33 58 83 9 34 59 84 10 35 60 85 11 36 61 _ 86 12 37 62 87 13 38 63 88 14 39 64 89 15 40 65 90 16 41 66 91 17 42 67 92 18 43 _ 68 93 19 44 69 94 20 4S 70 95 21 46 71 96 22 47 72 97 23 48 73 98 24 49 74 99 25 50 75 100 IN ACCORDANCE WITH THE CRITERIA OF PROTOCOL TAS 106, THIS ROOF ASSEMBLY HAS PASSED THE STATIC UPLIFT QUALITY CONTROL TES . J) rd�"Z .�1 1 RESPECTFULLY SUBMITTED BY: \rk(- ��%�— ��2��s Vinayagar M. Balakrishnan V. P. E. Lic# 63107 Miami -Dade Lab Certification # 07- 0612.11 State of FL Certificate of Authorization # 27273 Sketch of Roof Job 1 t @O V--gc' Sr - Sheet Number Zof "Z Contractor Qt moo C41 Checked By Scale la 0M4 t. Fr- 111111111P431111111111111111111,7111eP 1111111•1011A `lif , ►' "� cam' I I t Notes: NOTICE OF COMMENCEMENT A RECORDED COPY MUST BE POSTED ON THE JOB SITE AT TIME OF FIRST INSPECTION PERMIT NO. r*V131C1 TAX FOLIO NO. // 320.(- 0 /8-4/4 ) STATE OF FLORIDA: COUNTY OF MIAMI -DADE: THE UNDERSIGNED hereby gives notice that improvements will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement. 1. Leg 1111111111111111111111111111 CFN 2008R106 1 6, 1 56 OR Bk 26498 Ps 3306 °r (fps) RECORDED 07/28/2008 14 :38:36 HARVEY RUV'IH, CLERK OF COURT MIAMI-DADE COUNTYP FLORIDA LAST F'AGGE escription of property and street/address: //o ® /JO' 97 Si ,4' m,w Sioie4S 4V 'L S° c Sce 6 8 -6, ` Loi' 2. D cription of improvement: (fiatfry 3. Owner(s) name and address: /I/&' 64-/ $, /r-/ Peep �0 � 1p3 �' � /14,A., Interest in property: 3, Name and address of fee simple titleholder: 4. Contractor's name and address: (4_ S. gf d 0 J f- Pa iv4 S cis "-L 33x3 AA 5. Surety: (Payment bond required by owner from contractor, if any) Name and address: .� Amount of bond $ 6. Lender's name and address: 7. Persons within the state of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)7., Florida Statutes, Name and address: 8. In addition to himself, Owners designates the following person(s) to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b), Florida Statutes. Name and address: �- 9. Expiration date of this Notice of Commencement: (the expiration date is 1 year from the date of recording unless a different date -is specified) Sign ire of Owner Print Owner's Name •gypines Si9/Ley Sworn to and subscribed before me this 9 day of Notary Public�1 �9 Print Notary's Name My commission expires: WAN PUBUC TA3tE OF FICA MEAINE A. DUBPIN of lSi 07 2001) Bon . ed Thra Adan c Bonding tto% Ilea Prepared Address: S b � T 7 4-- -t- /t'tml44L S/(bee) /=( 3413 STATE OF FLORIDA, COUNTY OF DADE 1 HEREBY CERTIFY that this is PY of the original filed 1 >. _ on dal' of Miami Shores Village wilding Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 BUILDING PERMIT APPLICATION FBC 2004 iRfCEOVD JU 8 2006zas Permit Type (circle): Building Electrical Permit No. r Permit No. Plumbing Mechanical Owner's Name (Fee Simple Titleholder) f407C.$ ! , 1C7 a� /'J 2HJ Phone # d d Owner's Address / / / /. 4,) e" 5'? °sue ` ( ✓ City 7"/ l /444, S .IQ) /- e5 State Ft Zip 3 lam( 3 Tenant/Lessee Name Phone # Job Address (where the work is being done) lie) t-5 i 7 9 3 j City Miami Shores Village County Miami -Dade Zip FOLIO / PARCEL # `/ 30& 0 5 ®/ 3 0 Is Building Historically Designated YES NO Contractor's Company Name OheL) pl, f edd Contractor's Address / �� Iv C 7 City 2.4/ wri 6 Y e1' State P1 Qualifier Name eta.e,--70 k State Certificate or Registration No. C iC /t 31) L Phone # ZS 7 cP Z/2 Zip 33/ Phone # Certificate of Competency No. 60c3 Architect/Engineer's Name (if applicable) Phone # Value of Work For this Permit $ .Yq ti 3 .r Square / Linear Footage Of Work: 3 a 6 A Type of Work: ['Addition ['Alteration DNew epair/Replace ['Demolition Describe Work: 7-C�� I_ At STi £oij erns -16 /4 /` s S 8h-bid 6 0,9 4.- e .� r so ******* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** *Few * * * * ** * * ** * * * * * ** * * * ** * * * * * * * * ** * * * * * * * ** Submittal Fee $ ,feC Permit Fee $ 5 2-r416 Notary $ Training/Education Fee $ (0.L( Technology Fee $ 4342-- Scanning $ ar.O.) Radon $ CCF $ I 34 6 CO /CC Bond $ Code Enforcement $ Structural Review. $ DPBR $ Double Fee $ Zoning $ Total Fee Now Due $ See Reverse side -+ Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain-,- t to do the work and installations as indicated. I certify that.no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. The fore sin day of who is personal w n to nie�r -who has produced As identification and who did take an oath. NOTARY PUBLIC: instrument was acknowledged before me this �"g 2 , by JAS &.� r / Si°ZGZesr gn Print: A #-r P ale -SLATE OF FLO1W A My Commission Expires CATN J lei N l" A D 11FE T,e` lti t &tea ®%, 1Z i :.on' ?d .?t.n Atti u Her it -�,- -, s tiii? s L�9f • APPLICATION APPROVED BY: (Revised 02/08/06) Signature a 1 Contractor The forego g instrument was acknowledged before me his day of., 264 , by e, d r r who is 'personally known to me or who has produced as identification and who did take an oath. NOTARY PUBLIC: Sign: Print My Eti'Vel .,ft si mi- �sA, DUFFIni " Cot �h U,•, 7t) * * T Mud i ° 7 * * * * * * * * * * * * * ** Plans Examiner Engineer Zoning W(ame .'(coned 'Pave ?t9 Va /antwist 10050 NE 2nd Ave * Miami Shores, FI 33138 RFC) ;gil Phone 305-795-2204; Fax 305. 756 -8972 OWNERS'S AFFIDAVIT OF EXEMPTI ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR EXISTING SITE - BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES PERSUANT TO SECTION 553.844 F.S. To: Miami Shores Village Building Department 10050 NE 2nd Ave Miami Shores, FI 33138 Re: Owner's Name: Property Address: Roofing Permit Number: Date: P( Oo q7 51— felt slog-0 -W. 1P Dear Building Official: d wi c % ,t/r1 e certify that I am not required to retrofit the roof to wall .3onnections of my 9 buildin because: KT-he just valuation for the structure for purpose of ad valorem taxation is less than $300,000.00. Please attach proof of ad valorem taxation. The building was constructed in compliance with the provisions of the Florida Building Code (FBC) or with the provisions of 1994 edition of the South Florida Building Code (1994 SFBC) 74 ,» c S Ct 3igffture Print Name State of Florida 7ounty of Dade The undersigned, being the first duly sworn, deposes and says that he /she is th KLQ for the above )roperty mentioned. Sworn to and subscribed before me this a day of A O®0 0 p 'iotary Public, Sate of Florida at Large VA'nen the lust valuation of the structure for purpose of ad valorem taxation is equal to or more than $300.000.00, and the b :f3t1. nor a 1994 SFBC. Then you must.provide a building application f ro-a Gsmeral Contractor for the Roof to Wall connec WEARY PMC-STATE OF FLORIDA T H RJNE A. DUFFJN coax ssi� 3998 � a€fs , att�do. toe, ROO ASSEMBLIES AND ROOFTOP STRUCTURES Iorida Building Code • • ••. • . • • • • ••. •. •. • • • •• •• • RRd� • • 1VED: ••• elocity Hurricane Zone Uniform Permit Application Form. • • • • • • • • • •. • • • •• • • •• ••• •• Infor[najicgnj • : • : ; • • • . jC� S Contra or ' :�' m`: �.._. v r.s GrvlUtl(C ,�,jNeq .; Job Address ROOF CATEG,QRY Low Slope ❑ Mechanically Fastened Tile JMortar/Adhesive Set Tile ❑ Asphaltic ❑ Metal Panel/Shingles ❑ Wood Shingles/Shakes Shingles ❑ New Roof ❑ Prescriptive BUR -RAS 150 ROOF TYPE XReroofing ❑ * Recovering ❑ Repair 0 Maintenance ROOF SYSTEM INFORMATION Low Slope Roof Area (SF) Steep Sloped Roof Area (SF) 0279/ Section B (Roof Plan) Sk tch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. ineiude dimensions of sections and levels, clearly identity dimensions of elevated pressure zones and location of Pa''aaPets. Total (SF) 3-40 1 N X -T 1- 3f Lt NQ 3 2oUf 2 1 32 ..s A 3_5P .;RU"'w:TTii7tT.l!'IIB IMMIIIPIlimillt ni,a... Mil M..,...rMI iwwn, *-4 • j ■Mi iniMI MIMI INN -I I Immem I, SUBJECT TO:....�:. STATE AND CaleiftillitAIONSIMAIIMS RFOd -f381 FLORIDA BUILDING CODE — BUILDING • • ••• • • • • • ••• •• • • • •• •• • •• • F OP ASS €MBL =ES;4ND ROOFTOP STRUCTURES • • • • • • • • • • ••• • • • • ••• Florida Building Coctegdjtign2Q0t1,• • :: •.• High - Velocity Hurricane Zone Unifori nI�ennit Applikc��atloN Porm. • . • • • Surfacing: ((- 4-AJJ (� • Fasfaner jacni far 31rt.lhorfaase Sheet Attachment: • • • •• • Flea!! 1• 't oc e@ Cap, @ 1 " oc Perimeter: 6 " oc 0 Lap, # Rows (1Is. 0 " oc r � ..0CK� Section C (Low Slope Application) Fill in specific roof assembly components and identify manufacturer (If a component is not used, identify as "NA ") System Manufacturer: 6.44— Product Approval No.: 43 Q50/.. 02- Design Wind Pressures, From RAS 128 or Calculations: Pmax1:. 4/1T Pmax2:,- W- G Pmax3:., 12-4. 3 Max. Design Pressure, from the specific Product Approval system: . 5 Deck: Type: Gauge/Thickness: 3 /c� Slope:.�q.( Anchor/Base Sheet & No. of Ply(s): Anchor /Base Sheet Fastengr ding Material: insulation Base Layer: k) i ?t— Base insulation Size and Thickness: ii h-- Base Insulation Fastener onding Material: Top Insulation Layer: /14._ Insulation Sizq and Thickness: jJ tir Top Insulation Fasener/Bonding Material: Base Sheet(s) & No. of PIy(s): CAS---TI/1414 8C) Base �eet F stener 4 g �ll1414 I: Ply Sheet(s) & No. of PIy(s): f— sfelle ') L (j o�ndin Mat Top Ply Fastener /Bondi I: FLORIDA BUILDING CODE — BUILDING Corner: " oc @ Lap, # Rows Number of Fasteners' Per Insulation Board: Field ���� erimeter Corner Illustrate Components Noted and Details as Applicable: Woodblocking, Gutter, Edge Termination, Stripping, Flashing, Continuous Cleat, Cant Strip, Base Flashing, Counter - Flashing, Coping, Etc. Indicate: Mean Roof Height, Parapet Height, Height of Base Flashing, Component Material, Material Thickness, Fastener Type, Fastener Spacing or Submit 1402. yaty -clxse d yc PO4 1+044' �4 4f rEie+,+C � 4'r i i7 ,dab /FI5. ► RS Plc ,e7e ..trap �� I ?'‘e 4 ,& / r 2,y' ,1c4 _. Brec Nr i.I_r /,alp &)Tit / C51 r.J FT. i Par ps ih'-4.1,0C_ __ .vy/A. ¢.r Gr slu x'45 c y/ j le 30-1 ft if iga6 -82,6 - „B ,...T_.. _. - /� It.> 4f 745 -= $ Parapet Height 1 / Mean Roof Height 15.33 ROOF ASSEMBLIES AND ROOFTOP STRUCTURES 15.34 • •• • • • • • ••• • • • ••• • • • •• •• • • • • • • • • • ••• • • • • • • • • • ••• • • • • ••• Florida Building Code Edit n 2.1394••• High - Velocity Hurricane Zone Uniform Peem4 Application 5o'r•n.• • • • • • • • • ••• • Section D.�S epSlopec�_RQof-System) Roof emillact u re r :- - - - - -- Notice of Acce_ tance Numbyr: • • • • • • • • • • • • • • • • • • • - •• • -•_. •• ••.- --• • • • • • • • IVlinimum Design Wind Pressures, If Applicable (From RAS 127 or Calculations): Maximum Design Pressure 1 (From the Product Approval Specific System): Roof Slope: _: 12 Ridge Verftilation? Fastener Type & Spacing: Adhesive Type: y� liifs-, / t( Type Cap Sheet: 7 /J d Steed Sloped _Roof System Descrip-tion Deck Type: fd 4-744 Type Underlayment: 2 ZC -moo Insulation: Fire Barrier: Mean Roof Height: Roof Covering: /1_ 654(5/ �i(, Type Size rip !Aeotti</ Edge: onto _ G'4l vt-- FLORIDA BUILDING CODE — BUILDING 44F140-lei AND ROOFTOP STRUCTURES • • • • • • • • • • • • • ••• • • • • • • • • • • • • • ••• • • • • ••. Florida Building Code Edition •2004 ••• • • • High - Velocity Hurricane Zone UnIto=mpegtttlt ApplI tl9ti Form; ; • • • • • • • • • • • • • Section E (Tile Calculations) • • • For Moment based tile systems, choose either Method 1 or 2. Compare the values for Mr with the values from Mr. If the Mr values are greater than or equal to the Mr values. for each area of the roof, then the tile attachment methoi l 9cctptaDle. • • • • • • . • • ••• • • • • •• • Method 1 "Moment Based Tile Calculatiiddh s •l r RASP 12� • • • • • (PI . � x X - 27'�/ Q34R- Mg: 35 = Mr1 : "o 7 • Product Approval Mf, • (P2:04, x X .i1'/$ fSMg, 3S= Mr, 44 Product Approval Mr 34 7 ����' y .21‘141/-8q-1,44/4-". ���� x A ' Mrf3�G -'-J Product Approval Mr3ag. Method 2 "Simplified Tile Calculations Per Table Below" Required Moment of Resistance (Mr) From Table Below Product Approval Mr Mr required Moment Resistance* Mean Roof Height -, Roof Slope 4, 1 15' 2 20' 2 25' 3 30' 4 40' 2:12 3 34.4 3 36.5 3 38.2 3 39.7 4 42.2 3:12 3 32.2 3 34.4 3 36.0 3 37.4 3 39.8 4:12 3 30.4 3 32.2 3 33.8 3 35.1 3 37.3 5:12 2 28.4 3 30.1 3 31.6 3 32.8 3 34.9 6:12 2 28.4 2 28.0 2 29.4 3 30.5 3 32.4 7:12 2 24.4 2 25.9 2 27.1 2 28.2 3 30.0 *Must be used in conjunction with a list of moment based tile systems endorsed by the Broward County Board of Rules and Appeals. For Uplift based tile systems use Method 3. Compared the values for F with the values for Fr. If the F' values are greater than or equal to the Fr values. for each area of the roof, then the tile attachment method is acceptable. Method 3 "Moment Based The Calculations Per RAS 127" (Pt: x L = x w: _ _) - W: x cos B = Fri Product Approval F Product Approval F Product Approval F (P2: x L = x w: _ _) - W: x cos 0 = Fr2 • x xw: =) -W: x cos0 =Fr; Where to Obtain information Description Symbol Where to find Design Pressure PI or P2 or P3 RAS 127 Table I or by an engineering analysis prepared by PE based on ASCE 7 Mean Roof Height H Job Site Roof Slope 0 Job Site Aerodynamic Multiplier .i Product Approval Restoring Moment due to Gravity mg Product Approval . Attachment Resistance Mr Product Approval Required Moment Resistance Ma Calculated - Minimum Attachment Resistance F Product Approval Required Uplift Resistance Fr Calculated Average Tile Weight W Product Approval Tde Dimensions L = length W = width Product Approval All calculations must be submitted to the building official at the time of permit application. FLORIDA BUILDING CODE - BUILDING 15.35 6 BUILDING CODE COMPLIANCE OPPICE (CCO) PRODUCT CONTROL MOWN . . •• •• • • • • • • • • • If • 6 ••• • • • • 4 • • i:•• • I. • • •00 • • • 06• • • • •• •• • • • • • • • • • •0• • • • • • • • • • 1•• • • • • •s• • • • • • • • • • • • • • • • • • • • • • • • • • • ••• • .WITAZ:1111Alg COUNTY, FLORIDA )4E7140-DADE PLAGUE EUXD1N0 • 140 MST SUMO STREET, SVETE 1603 • • MrA,141, VLDR1DA 33130-1563 l'001;) 375-2910 VAX (305) 375-2905 NancE0F4 NcE 0A 4. • • • • • ... Clay Forever, LLC 6801 NW 71 Avenue Miami, FL 33166 SCOPE: This NOA is being Waled under the applicable rules and rgu1ai.ns governing the use of construction Materials. by the Board daubs and Appeals (BORA) to be used in Mia i :Ude County and other areas where &Slowed by ti The documentation submitted has been reviewed by Miami-Da e County Produce Control Division and aocepttd tile Authority Having Jurisdiction (ART), This NOA shall not be valid after the expiration date statedilbelow. The Ivliarni•Dade Couety Product Control Division an Miami Dade County) and/or the ART (in areas ogees than Miami Dade Comuy) reserve the right to have this product or material tested for quality assurance putpbses If this product or raateristi fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the Alif may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right material fails to meet the requirements of the applicable buildiri code. to revoke this acceptance, if it is determined by lvliarni-Dade linty Product Control Division that this product or This product is approved as described herein, and has been desil ed i ) comply with the Florida Building Code including the High Velocity Hurricane Zane of the Florida Buil :.;zig 1 ode. DESCRIPTION Altusa "S" Clay Roof Tile LABELING: Bach unit shall bear a peunactent label with the 1ai u:factures name or logo, city, state and following statement: "Miami-Dade County Product Control Ap oved"omless otherwise noted 'herein. RENEWAL of this NOA shall be considered after a renewal a plication has been filed and them has been no change in theapplieable building code negatively affecting dic et fonnance of this product. TERMINATION of this NOA. will occur after the expiration dcc or if there has bean a revision or change in the materials, use, andfor mannbenta o! the product or process. M 190.'s of this NOA. as an endorsement of any Product, for sales, advettaing Or any oth6x purposes shall auto nAlly terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination andlire ;naval of NOA. ADVERTISEMENT: The NOA number preceded by the worlds Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. I any portion of the NOA is displayed, then it shall be done in its entirety. INSPECT/ON: A copy of this entire NOA shall be provided tol the user by the manufacturer or its distributors and shall be available for inspection at the job sit e. at the request' ot the Building Official. This renews NOA #06-0706.09 and consists of pages 1 through / The submitted documentation was reviewed by Alex Tigera. kr NOA lqo.: 07-0919,05 Expiration Date: 12116/12 Approval Date: Page 1 of 7 Uec. [U..1 ROOFING ASSEM}1L `l APPROVAL Category: Sub - Category: Material: 1. SCOPE Rooting Roofing Tiles Clay • • •• •• • • • • • ••• • • • ••• • • • •• •• • • • • • • • • • • ••• • • • • • • • • • 2 ••• • • • • ••• dU, • i ••• • • • • • • • • • • • • •' • • . • • • • • • • • • ' • ••• • • • • • • • • • • • • L! r L • • • • • • • • • 1•• • • • •• •:• •• • • • • • • • • • • • • ••• •• • Th +s renews roofing system using Altusa One Pi T e S' Clay Roof Tiles, as manufactured by Alfavtrin Del Turbic, S.A. (ALTUSA) in Venezueland described in Section 2 of this Notice of Ar.;eptance. For locations where the pres.-ure recut ments, as determined by applicable Building Crldr, -loss not exce:e + the desian pressure values obtained by calculations in compliance with RAS 1" <7 using the value; listed in lion 4 he; tin. Thip attachment calculations shall be done as a moment based system. i i` I. 2. PRODUCT DESCRIPTION Mantjf turgid by APOWt Altusa One Piece 'S' Tile Trim Pieces Clip • Clip ! tmeutsions L= 18 ;1" W = 10.5" !iz' thick nominal 3,25" high Length: varies Width: varies varying thickness L 6" D = 0.125" .eth =2" W =✓2" 0.05" thick 2.1 SUBMITTED .R'VIDENCE: Test Aa1cv • IBA Consultants, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engiineering, Inc. The Center for Applied Engineering, Inc. Celotex Corporation Testing Z0 •d Test Product $tech a s RtaititIA TAS 112 TAS 112 TAS 114 TAS 114 Tfler 2397 -115 94-083 94 034 25- 72[:0 -1 Project No. 307025 Test #MDC -73 MTS 520649 211• sigh profile clay roof tile. For direct deck or bitten nail -on, mortar set or adhesive set itpplications with minimal headlap of 2 -1/2" accessory tr:rn, clay roof pieces for use at ps, rakes, ridges and valley terminations. fanufactured for each tile profile. ale clip I." Shaped tile clip me .euort Date ASTM C 1167 06/28/07 Static Uplift Testing April 1994 TAS 101 (Adhesive Set) Stack Uplift Testing May 1994 TAS 101 (Mortar Set) Static Uplift Testing Feb. 1995 TAS 102 (Quick -Drive Screws, Battens) Wind Driven Ram Oct. 1994 TAS 100 TAS 102(A) May 2000 NOA No.: 07-0919.05 Expiration Date: 12/18/12 Approval Date: Page 2 of 7 400 .8008 -9z.; �. -. L:;. IUU/ It :3crw Test Aeepcv, PRI Asphalt Technology, Inc. Red land Technologies Redland Technologies Redland Technologies Redland Technologies Redland Technologies Walker Engineering, Inc. Walker Engineering, Inc. Walker Engineering, inc. Walker Engineering, Inc. Walker Engineering, Inc. 3. LIMITATIONS 3.1 Fire classification is not pan of this acceptance. 3.2 For mortar or adhesive set tile applications, a Otatic field uplift test shall be performed in accordance with RAS 106. ' • j 3.3 Applicant shall retain the services of a Miami -lade Coe ity Certified Laboratory to perfonu quarterly test in accordance with TAS 112, app ndix 'A'. Such testing shall be submitted to the Building Code Compliance Office for review 3.4 Minimum underlayment shall be in cornpliane with the - applicable Roofing Applications Standards listed section 4.1 herein. 3.5 30/90 hot mopped underlayment applications 4 be installed perpendicular to the roof slope- unless stated otherwise by the underlayment ma 'al manufacturers published literature, 3.6 This acceptance is for wood deck application Minimum deck requirements shall be in compliance with applicable building code. 3.7 May be installed on slopes 7:12 and greater. 4. INSTALLATION 4.1 'Aituee One Piece S' Clay Roof Tile and its components shall be installed in strict compliance with Roofing Application Standard T F +S 118, RAS 119, and RAS 120. 4.2 Data For Attachment Calculations Test Identifier CLF- 003 -02 -01 7161 -03; Appendix III 7161 -03 Appendix II Letter Dated Aug. 1, 1994 P0631 -01 • • •• •• • • • • • • • • • • :1 • P0402 Calculations Evaluation Calculations Evaluation Calculations Evaluation Calculations Evaluation Calculations ••• • • • • • • •• •• • • • • • • • ••• • • • • • • • ••• • • • • •. • • • • • ••• 19U U L ••• • • • • • • • • • • • • • • • • • • • • • • Test rnefA ort' • • • • • • • • •• • CE TAS 102 October 2001 ,1 .•• • • • •• ••• •• '. •.. T'AS 1D2. •. Dec. 1991 • • w1r:Q Tymne?T;star? ••0 Dec. 1991 TAS 108 (Nail -On) Wind Tunnel Testing TAS 108 (Nail -On) Wind Tunnel Testing TAS 108 (Mortar Set) Withdrawal Resistance !Testing of screw vs. smooth shank nails Aerodynamic Multiplier 25 -7123 25 -7094 25 -7496 25 -7584 ?i- 7804b -8 25- 7804 -4 & 5 15-7848-6 Aug. 1994 July 1994 Sept. 1993 March 1999 March 1995 February 1996 April 1996 December I996 80'd S8£ ,9t78; I; NOA No.: 074919.05 Expiration Date: 12116/12 Approval Date: Page 3 of 7 Q :00 8000 -QZ -- a8 [ J ?C. Ll). LU1 it: 'Arts! • • ••• • • . • • • • • • • • • •. •• ••• • • • • • • ••• • • • • • • ••• • • • • • •' • • • • • • •.. • • • • ••e IV e. t! • c . • : - • - ... • . - .. • • • • • • • • • ••• . • • • . . Table 1: Average Weight (W) a '. Dimensions (lx w ) The Profile Weight -W (ibf) ' M@ngth- 1•0) :. i••, Width -w (ft) Musa ' ' Tile 6.9 1.52- • /' • •• 0.875 Table 2: Aerod amic M ti hers - X ft The Profile X(t) j Batten plication A. (ft ) Direct Deck A. ,lication 0.274 Altura 'S' Tile j O 3 Table 3! Restoring Moments duc1to Gravity - Mm (ft -fbf -1 I Tile Profile 3 " :12" or less 4 ": 12" 5 ": *2" T 6 ": 12" } 7": 12" or greater Altuse ` ''Mile Battens 'red DAck Battens Direct Deck battens : Direct sirens tick Direct Deck Battens Direct Deck 4,89 4.47 5 3 4,40 1 5.27 4.31 ! 5.18 J 4.20 5.03 4.08 Table 4: Attachment Resistance Expressed as a Moment - Mr (ft-lbf) for Nall -On Systems Tile Profile Fastener Type Direct Dec (Min 151321 plywood) i i Direct Deck (Min. 19/32" plywood) Battens Musa 'S' Tile 2.10d Ping Sr ank Nails 28.6 41.2 19.4 1 -10d Smooth or Screw Shank Nall 5.1 if 6,8 2.8 2.10d Smooth or Screw Shank NW is .crew 6.9 9.2 7.3' • 7.74 28.7 28.7 N/A 2 . #8 Screws 58.2 i 58.2 26.8 1-10d Smooth or Screw Shank Nail (Field Clip) 23.1 23.1 19.0 1.10d Smooth or Screw Shank Nail (Save Clip) 29.3 29.3 24.0 2.10d Smooth or Screw 27.6 ;�' Shank Nails (Field Clip) , 27.6 38.6 2 -10d Smooth or Screw 38.1 It 38.1 Shank Nails (lave Clip) I 41,8 • 1 Screw with Altusa Clip (`ire clip details) Aituea "S" Tile' 1 Screw with clip (at the head of tile 187.1 , 187.1 N/A Altusa "S" Tile' 1 Screw with clip (at the water course of tile) 352 i li 35.2 • N/A 1. Screw must be installed in the inside nail hole located nearest t4 the hump of iher tile. NOA No.: 07.0919.05 Expiration Date: 12/16/12 Approval Date: Page 4 of 1±0 :00 800Z-42-951,4 c .. Li. is ; ; I j ; • • •• ••• • • • . • • • • ■ ••• • • • • • ••• • • • • ••• •• • • • • • • • • • Lo t • • ••• • • • • • • • • •' • • • • • •' • • •' • • • • • • • • •• • • •• • • • • ••• ••• • • • • • • • • Table 6: Attachment Resistance Expr for Two PattyAdhes!ee Tile Appilcatio Tile Profile Musa 'S Tile j 3 sed as a Moment MI (ft -Ibf) AtuSyst$ ••• .. ; : : : :1 • Adhesive 2 See manuiestures cae,ponent approval for inetellaltpn requirenYAnts. ' Flexible Products Company Tlleeond Average weight per pal y 10.7 grams Polyfoem Product, Inc. 'verage weghl per pal 1 slurps. :Min mum Attachment Resistance 29.3 Table 7: Attachment Resistance Expre sed as a Moment - Mt (ft Ibf) for Single Patty Adhesiv Set Systems Tile Applioationl Tile Profile lltusa 'S' Tile Po Mown PolyPromli Polyfoam Pol Pe ro'i 4 Large paddypaeement of 83 tLrams of PolyPro'"". 5 Medium paddy placement of 24 grams of PoyPsoTM. - Mln!mum Attachment Resistance 66.5' 38.78 -J Table 8: Attachment Resistance Expreeited as a Moment - Mi (ft -Ibf) for Mortar Set Sytems Tile Applicationli Mortar Sat' Tile Profile aVtusa'S' Tile 5. LABELING All tiles shall bear the imprint or identifiable mrk:ng of the manufacturer's nacre or logo, or following statement: "Miami -Dade County Prod1ct Control .Approved ". Attachment Resistance • 24.50 IDENTWICATION MARK FOR A TUSA'S' CLAY ROOF TILE LOCATED UNDE TA *TILE 6. BUILDING PERMIT REQUIREMENTS j 6.1 Application for building permit shall be acc pmpanied by copies of the following: 6.1.1 This Notice of Acceptance. li • 5.1.2 Any other documents required by tlie Building Official or applicable building code in order to properly evaluate ttii installation of this system. 20'd CBME 2.88 90 S'Ilt, 400$ tpra,I MISLlOEN NOA No.: 07.0919.05 Expiration Date: 12116/12 Approval Date: Page 5 of 7 80:00 80M-8Z-33.4 7c... JO. L :3+r • • • • ••• • • • • • • • •• • • • • • • • • • • • • • ••• • • 01. • • • • ••• ••• • • • • ∎cu . J L ! • • • +• • • • • • • • • • • • • • • • • • f' • • • • ••• • • • • • • PROFILE DRAW « jNGS ALMA `S' CLAY Rr� � ••. • • • • • • . • • • •••. /1" • • • • • • • "SPANISH 8" TILE SY ALTUS MP.) CLIP DETAIL1 2.112" OVERLAP (COVERS PIN H ) - SCREW IN THE INSIDE HOLE NEAREST TO THE HUMP OF THE TILE �• �� f-- -DECK // . CLIP WITH ONE(1) SCREW ._•_, A'TACHEO TO OECIC CLIP PLACEMENT DETAIL i, al"71 400 S' CLIP NOA No.: 07.0919.05 Expiration 12/16/12 Approval Date; Date: Page 6of7 04U¢ - ,.1 ## GPI MOO OO $OO -93 -834 LO'd MUM Uec. a LVUI SCREW (FOLDS SCREW (HOLDS CLIP ONTO DECK) 'SPANISH 8" TILE RY ALr ,sA (TYP.) • • ••• • • • • • • • • • • • • • ••• • • • • .•• ••• • • • • • • • • • • • • • • • YU. ••• ••• • • • 1 • • • • • ••• • • • • •• • I • • • • • • ••• ••• CLIP DETAILS (C • • • •• • • • • • • ••• 2 112" OVERLAP (COVERS PIN HOLD) • • • • • • ••• • • • • • • • • • • • • • ••• SCREW IN THE INSIDE NAIL HOLE NFAFCST TO THE HUMP OP THE Tti E n L, CLIP PLACHMENT DKTAIL DECK 1 'la' 1 3/4' NO 61E" I II II GALVANIZED ME'A•. CL:a LO'd 1,88 90 END OF THIS 4CCEPjIANCE i1 2'7.11 4008 AYRNY8$3.1 WSW NOA No.: 07- 0919.05 Expiration Date: 12/16/12 Approval Date: Page ?of7 1+0:00 8002- 9?. -83A BUILDING CODE COMPLIANCE OFFICE (BCCO) PRODUCT CONTROL DIVISION NOTICE OF ACCEPTANCE OA Polyfoam Products, Inc. 11715 Boudreau Road Tomball, TX 77375 • • •.. • • • .•• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • ... • • • • • • • • • • • • • • •.• • • • • ••• • ••• • • . . • . . . . . . . . . . • • MPAlYN�DAD{ C•OILWCY. FLORIDA '. • • IVY RO- •BADE'Fj,AG4A BUILDING 140 WEST FLAGLER STREET, SUITE 1603 MIAMI, FLORIDA 33130 -1563 • • • • • (35) W 5 2 :a • FAX (305) 375 -2908 • • • • • • • •. • • • • • •.•.•• SCOPE: This NOA is being issued' under the applicable rules and regulations governing PrcThe documentation submitted has been reviewed by the BCCO and accept by he Building Code and Product Review Committee to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The BCCO (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for assurance purposes. If this product or material fails to quality the expense of such testing and the AHJ may immediately elperform ', or suspend or er, the manufacturer will incur t or material within their jurisdiction. BCCO reserves the right to revoke this accepta if it is determined by BC O that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Polypro® AHI60 RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA No.01- 0521.02 and consists of pages 1 through 7 The submitted documentation was reviewed by JRrge L. Acebo. NOA No.: 06- 0201.02 Expiration Date: 05/10/11 Approval Date: 04/13/06 Page 1 of 7 ROOFING ASSEMBLY APPROVAL: Category: Roofing Sub Category: Roof tile adhesive Materials: Polyurethane • • •.. • • • ••. .• • • • • • .. • • • • • • • • • • • • • • .•• • • • • • ••• • • • • ••• • • • . • • • • • • • • • • • • • • • • • • • • •.. .. ...• • • • ••• • • • •• ••• •• • • • SCOPE: • . • • • • • • This approves Polypro® AH160 as manufactured by Polyfoam Products, Inc. as described in Section 2 of this Notice of Acceptance. For the locations where the design pressure requirements, as determined by applicable building code, does not exceed the design pressure values obtained by calculations in compliance with Roofing Application Standard RAS 127, for use with approved flat, low, and high profile roof tiles system using Polypro® AH 160. Where the attachment calculations are done as a moment based system for single patty placement, and as an uplift based system for double patty systems PRODUCTS MANUFACTURED BY APPLICANT: Product Dimensions Polypro® AH160 N/A Foampro® RTF1000 N/A ProPack® 30 & 100 N/A Test Specifications TAS 101 Product Description Two component polyurethane foam adhesive Dispensing Equipment Dispensing Equipment PRODUCTS MANUFACTURED BY OTHERS: Any Miami -Dade County Product Control Accepted Roof Tile Assembly having a current NOA which list moment resistance values with the use of Polypro AH160 roof tile adhesive. PHYSICAL PROPERTIES: Property Density Compressive Strength Tensile Strength Water Absorption Moisture Vapor Transmission Dimensional Stability Closed Cell Content Test ASTM D 1 622 ASTM D 1621 ASTM D 1623 ASTM D 2127 ASTM E 96 ASTM D 2126 ASTM D 2856 Results 1.61bs. /ft.' 18 PSI Parallel to rise 12 PSI Perpendicular to rise 28 PSI Parallel to rise 0.08 Lbs./Ft2 3.1 Perm / Inch +0.07% Volume Change ® -40° F., 2 weeks +6.0% Volume Change ®158°F., 100% Humidity, 2 weeks 86% Note: The physical properties listed above are presented as typical average values as determined by accepted ASTM test methods and are subject to normal manufacturing variation. NOA No.: 06- 0201.02 Expiration Date: 05/10/11 Approval Date: 04 /13/06 Page 2 of 7 EVIDENCE SUBMITTED: Test Agency Center for Applied Engineering Miles Laboratories Polymers Division Ramtech Laboratories, Inc. Southwest Research Institute Trinity Engineering Celotex Corp. Testing Services Test Identifier #94 -060 257818 -1 PA 25- 7438 -3 25- 7438 -4 25- 7438 -7 25 -7492 NB -589 -631 9637 -92 01 -6743 -011 01- 6739- 062b[1] 7050.02.96 -1 528454 -2 -1 528454 -9 -1 528454 -10 -1 520109 -1 520109 -2 520109 -3 520109 -6 520109 -7 520191 -1 520109 -2 -1 • • ••• • • • ••• • • • • • • • • • • • • • • • • • • • • • • • • • ••• • • • • • • • • • • • • • • • • • • ••• • • • • • • .•• • ••• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • ••.• • • . • .. • .•.• • • ..• • • • Test Name/Report TAs 101 :•':: •• T'aS 101 •• SST ;1493 • SSTD 11 -93 SSTD 11 -93 ASTM D 1623 •• Date ••'04/08/94 .' 12/16/96 • •.1 G/8/95 11/02/95 12/12/95 02/01/94 ASTM E 108 04/30/93 ASTM E 108 ASTM E 84 TAS 114 11/16/94 01/16/95 03/14/96 TAS 101 10/23/98 TAS 101 12/28/98 TAS 101 03/02/99 LIMITATIONS: 1. Fire classification is not part of this acceptance. Refer to the Prepared Roof Tile Assembly for fire rating. 2. Polypro® AH 160 shall solely be used with flat, low, & high tile profiles. 3. Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120. 4. Roof Tile manufactures acquiring acceptance for the use of Polypro® AH 160 roof tile adhesive with their tile assemblies shall test in accordance with TAS 101. 5. Roof Tile manufactures acquiring acceptance for the use of HANDI -STICK roof tile adhesive with their tile assemblies shall test in accordance with TAS 101 with section 10.4 as modified herein. I ■ F 2 F'= MS NOA No.: 06- 0201.02 Expiration Date: 05/10/11 Approval Date: 04 /13/06 Page 3 of 7 INSTALLATION: • • ••• •• •• • • • • • • • • • • • • • ••• • • • • • ••• • • • • • • ••• •• •• • • • • • • • • • • • • ••• • ••• • • • • • • • •••• • •• • • • • • • • • • e f • • 1. Polypro® AH160 may be used with any roof tile assembly ha'bing a curr8rrN(7A that lists u?ilift ••• • • •• •••• • resistance values with the use of Polyproo A11160. 2. Polypro® AH160 shall be applied in compliance with the Component A corresponding Placement Details noted herein. The roof tile assse nblyys ad1esiva ajtechinent with the use of Polypro® AH160 shall provide sufficient attachmen esr ce s based system, to meet or exceed the uplift resistance determined compliance with Miiiammi Dade County Roofing Application Standards RAS 127. The adhesive attachment data is noted in the roof tile assembly NOA 3. Polyproo AH160 roof tile adhesive and its components shall be installed in accordance with Roofmg Application Standard RAS 120, and Polyfoam Products, Inc. Polypro® AHI60 Operating Instruction and Maintenance Booklet. 4. Installation must be by a Factory Trained 'Qualified Applicator' approved and licensed by Polyfoam Products, Inc. Polyfoam Products Inc. shall supply a list of approved applicators to the authority having jurisdiction. 5. Calibration of the Foampro.4 dispensing equipment is required before application of any adhesive. The mix ratio between the "A" component and the "B" component shall be maintained between 1.0- 1.15 (A): 1.0 (B). The dispense timer shall be set to deliver 0.0175 to 0.15 determined at calibration. No other settings shall be approved. pounds as 6. Polypro® AH160 shall be applied with Foampro RTF1000 or ProPack® 30 & 100 dispensing equipment only. 7. Polypro® AH160 shall not be exposed permanently to sunlight. 8. Tiles must be adhered in freshly applied adhesive. Tile must be set within 2 to 3 minutes after Polypro® AH160 has been dispensed. 9. Polypro® AH160 placement and minimum patty weight shall be in accordance with the Placement Details' herein. Each generic tile profile requires the specific placement noted herein. Table 1: Adhesive Placement For Each Generic Tile Profile Tile Profile Flat, Low, High Profiles High Profile (2 Piece Barrel) Flat, Low, High Profiles Flat, Low, High Profiles Placement Detail Single Paddy Weight Min. (grams) #1 35 #1 17 /side on cap and 34/ an #2 24 Two Paddy Weight per paddy Min. (grams) N/A N/A #3 N/A 8 LABELING: All Polypro® AH160 containers shall comply with the Standard Conditions listed herein. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or applicable building code in order to properly evaluate the installation of this system. NOA No.: 06- 0201.02 Expiration Date: 05/10/11 Approval Date: 04 /13/06 Page 4 of 7 • ... • • • ... • •'• • • • •'• • • • • • ••• . • • • • • • • • • • • • • • ••• • • • • •.• • • ADHESIVE PLACEMENT D>�'z'a ' • • ' • • • • • • • • • • • • • ••• 1 • • • • ••• • SINGLE PATTY • • • • • • +) Flea enough admire toachieve 11 to 23 Cyffonai2adator square inches ineonaet with the �tile ° aPP ns tht9 2) Turn covens upside down. Place adhesive 1121n` 101 T From outside edge oi cover Ile. Then install the Se. NOA No.: 06- 0201.02 Expiration Date: 05/10/11 Approval Date: 04 /13/06 Page 5 of 7 • • ••• • • •• •• • • • •• •• ••• • •� ••• • • • • • • • • • • • • • • • • • • ••• • • • • • • ••• • • • • • ••• ••• ADHESIVE PLACEMENT DET ;2 • • • • • • • • • • • • SINGLE PATTY • ' • • • •.• •• • • . • • • • • • • •• • • • NOA No.: 06- 0201.02 Expiration Date: 05/10/11 Approval Date: 04/13/06 Page 6of7 • • • • • • • • • ••• • • • • •• • • • • • •• •• • • • • • • • • • • • • • • • • • • • • • • • • •.. • • • • •.. • • • • • ••• ••• ADHESIVE PLACEMENT Dr$? • • • • • �►•�. 3 •••• DOUBLE PATTY • •• • • o • •• •• • ••. . . . . .• • • . • . • .• • • • . • . . . . . • • Nail through plastic cement jIn. 3 In. Single paddy on undedayment n, single ... on top of We END OF THIS ACCEPTANCE NOA No.: 06- 0201.02 Expiration Date: 05/10/11 Approval Date: 04 /13/06 Page 7of7 2075 4:13:41 FR BRADCO SUPPL't BUILDING CODE COMPLIANCE OFFICE CtiCCO) PROI3UCT CONTROL DIVISION , NOTICE OF ACCEPTANCE (NOA) 3015 838 2152 T O 3015 7588484 P. 0 1, 0 1 • • ••• • • •• •• • • • •• • • • • • • • • • • • ••• • • • • • • • • • ••• • • • ••• • • • • • •• • • • • •: MI•AI I -• epe CoTINFY•FLORIDA • 11'trnieeiledi n ddnt gtit meo . i4 WEST now STIWT,STitT1E 1603 MIAMI, FLORIDA t3130-1563 (305) 375-2901 FAX (305) 375-3908 • •• • • • •• ••• •. GAF Material Corporation 1361 Alps Road Wayne, NJ 07470 • • •. • • • • • •• • • • • • ••• •• Sever: This NOA ie being issued under the applicable rules and regulations governing the uae of construction materials. The documentation submitted has been reviewed by the DCCO and accepted by the Building Code and Product Review Committee to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (, This .NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Division (In Miami Dade County) and/or the A£D (in areas other than Miami Dade County) reserve the right to have this product or era aerial tested for quality assurrutce purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the Alit may immediately revoke, modify, or suspend the use of such product or. metcrial within their jurisdiction. BORAreserves the right to revoke this acceptance, if it is determined by Miami made County Product Cameo] Division that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, And has been designed to comply with the High Velocity Hurricane Zone of the Merida Building code. DESCRIPTION: GAF kuberoIdt9 Modified Bitumen Roof System for Wood Decks. LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein. 1ENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. . TERMINATION of this NOA will occur after the expiration date or if there has been a revision or chine in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami- -Dade County, Florida, and followed, by the expiration date may be displayed in advertising literature. 1f any portion of the NOA is displayed, then it shall be done in its entirety. INNSP'ECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. Ji TbiI,NOA rows NOA #02- 0408.16 and consists of pages 1 through 31. 'Thitiubmitted documentation was reviewed by Frank Zuloaga, B.R.C. NOA No ti3.4St)1.02 Expired= Date; 11/06/03 Approval Date: 10/23/03 Pate 1 of 32 * :* TOTAL PAGE .01 31 '6:* Membrane Type: SBS /SBS Cold Applied Deck Type 1: Wood, Non - insulated Deck Description: System Type E (1): • •.. • ••�• • • • • •• ••. ••• • • • • • • • ••• • • • • ••• • • • • • • ••• • • • • • • .•• • • • • • ••• • • • • • • • • • • • • •19/32" or greater plywood or wood plank decks' • • .. ; • � • : • • ••• • • • •• • '• • • • • • •• • • • • • • • • • • • • • • • ••• • • • • ••••••• Mm e: One or more plies of RUBEROID MOP SmaotG, Rruberonn Mpp 1,7h}FR, • • Ruberoid® Mop Granule, Ruberoid® Mop Plus granule,.ub d® 204 ; Ruberoid® 30 or Ruberoid® 30 FR or Ruberoid® Mop 11 or IitUBEROID • UltraCladTM SBS in adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. •' • . • . ; • . :•• • • • Or, • • • One or more plies of RUBEROID MOP Smoot klrJBI101DIENbp•Otanble, RUBEROID® Mop 170 FR, RUBEROID® Mop Plus Granule, Ruberoid® 20, RUBEROID® 30, RUBEROID® 30 FR or RUBEROID® Mop FR Dr RUBEROID UraCladTM SBS in RUBEROID Modified Bitumen Adhesive at an application rate of 1 -2 gal:/sq. Surfacing: (Optional, required if RUBEROID MOP Smooth or RUBEROID 20 is top membrane) Install one of the following: 1. Gravel or slag applied at 400 lb./sq. and 300 lbJsq. respect ively in a flood coat of approved asphalt at 60 Ib./sq. 2. GAFGLAS Mineral Surfaced Cap Sheet in an approved asphalt at an application rate of 25 lbJsq. ± 15%. 3. GAF Weathercote® MB +(Matrix 715 MB Coating), Applied at 1 to 1.5 galJsq. 4. Top Coat® Surface Seal SB(Matrix 602 SB Coating), Applied at 1 to 1.5 galisq. Maximum Design Pressure: See Fastening above NOA No: 03.0501.02 Expiration Date: 11/06/08 Approval Date:10/23/03 Page 27 01'32 , • • ••• • ••••• • • • • •• •• • '•' • • • • • • • • • • • • • ••• • • • • • • • • • ••• • • • • • • • ••• • WOOD DECK SYSTEM LIMITATIONS: •' • •' • • • • • • •' • • • • 1 A slip sheet is required with Ply 4 and Flex Ply TM 6 when used as a mech'aldcalfy fastened base or anchor sheet. 2. Minimum Wa" Dens Deck or 34 Type X gypsum board is acceptaMO tp lie iuorsjalded d+i+eedyover the wood deck. • ..... • • .. • • • • • • • ••• •• GENERAL LIMITATIONS: 1. Fire classification) not part of this acceptance, refer to a current Approved Rbofmg Materials Directory for fireatings of this product. 2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs sq., or mechanically attached using the fastening pattern of the top layer 3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size shall be 4' x 4' maximum. 4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at each sidelap and one down the center of the sheet allowing a continuous area of. ventilation. Encircling of the strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 12 lbs sq. Note: Spot attached systems shall be limited to a nun mum design pressure of -45 psf. 5,. Fastener spacing for insulation attachment is based on a Minim m4 Characteristic Force (F) value of 275 Ib£, as tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field-tested, are below 2751bf. insulation attachment shall not be acceptable. 6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum fastener resistance value in conjunction with the maximum design value listed within a specific system Should the fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing, prepared, signed and sealed by a Florida Registered Engineer, Architect, or Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117. 7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 117. (When this limitation is spedfcally referred within this NOA, General Limitation #9 will not be applicable.) 8. All attachment and sizing of perimeter mailers, metal profile, and/or flashing termination designs shall conform with Roofing Application Standard RAS 111 and applicable wind load requirements. 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for fastening at enhanced pressure zones (i.e. perimeters, extended corners and comers). (Whet limitation is specifically referred within this NOA, General Limitation #7 will not app , le.) 10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9B -72 of the Florida Administrative Code. END OF TIf IS ACCEPTANCE NOA No: 03-0501.02 Expiration Date: 11/06/08 Approval Date:10/23/03 - Page 32 of 32 • • • TGFU.R1306 - Roofing Systems Z 1 Underwriters Laboratories int.,, :..• •;• ••• ;• •• .. Page 1of55 • • • ••• • • • • • • • • • • • • • • •• • • • • ••• • • ••• • • • • • • • • • • • • • •• • • • • • • • • • • •• • • • • • • • • ••• • • • • • • TGFU.R1306 • • • . • • • • • • Roofing Systems ''• ....... . .: • P age Bottom Questions? Guide Information GAF MATERIALS CORP 1361 ALPS RD WAYNE, N1 07470 USA •• • • • • • Roofing Systems R1306 "Ruberoid 20" or "Ruberoid Modified Base Sheet" may be utilized as an alternate to Type G2 base sheets in any of the following Classifications. 1/2 in. thick (min) gypsum board or 1/4 in. thick (min) G -P Gypsum Dens -Deck® may be used in any existing noncombustible deck Classification. When this is done, the resulting roofing system is acceptable for use over combustible (15/32 in. min) roof deckt. The joints in the gypsum board and overlayment board are offset 6 in. with the joints in the deck. If polystyrene is part of the roof system, it must be placed below the overlayment board. Also, multiple plies of "GAFGLAS Ply 4" or "Ply 6" may be adhered to G -P Gypsum Dens -Deck hot asphalt. " EnergyGuard Ultra" is an acceptable alternate to "EnergyGuard" in any applicable Classification. "GAF Stratavent Eliminator Venting Base Sheet (Nailable)" may bemechanically attached or hot mopped over noncombustible decks and as a recover over existing roof systems. GAFGLAS Perlite Insulation may be utilized as a cover board over "EVERGUARD" insulation in any of the following systems. Unless o %rwise indicated, the roof insulation is mechanically fastened, adhered with hot mopping asphalt or' urethane insulation adhesive. Polystyrene reference in any of the following Classficatons include "ENERGuard EPS Insulation ". References to glass fiber insulation include " EnergyGuard Fiberglass Insulation ". ASPHALT FELT SYSTEMS WITH HOT ROOFING ASPHALT http: / /database.ul.com /cui- bin /XYV /temnlate/LISEXT /1 FR A Wish ownage.html ?name =T( .. 10M/04 • . ▪ TGFJJ.R1306 - Roofing Systems • ; TGFU.R1306 - Roofing Systems • • ••• • • • per 12 of 55 • • • • • • • • • • • • • • •• • • • • • • • • • ••• • • • • • •• • • • • • • • • ••• • • • • ••• Insulation (Optional): — Perlite, fiber glass, isocyanurate, urethane or perlite / isocyanurate composite. Base Sheet: — One or more layers Type G2 or G3 fastened Ply Sheet (Optional): — One or more layers Type Membrane: — "Ruberoid Mop 170 FR ". 16. Deck: C -15/32 Incline: 1/2 • ••S •• base shiej het mop�ad'of•nIe • • • • • • • • •• • • G 1, hot mopped in place. • l ni ;'ply • • • • • • •• • • • •• :" • • • • • • • • • • • • • . • • • • • • • • • •• • • • • • • • Insulation (Optional): — Perlite, fiber glass, isocyanurate, urethane or perlite/isocyanurate composite, offset 6 in. from joints. Base Sheet: — One or more layers Type G -2 or G -3 base sheet, hot mopped or mechanically fastened. Ply Sheet (Optional): — One or more layers Type G -1, hot mopped in place. Membrane: — One layer "Ruberoid Torsi Smooth" or "Ruberoid Mop Smooth— Membrane: — One layer ':,Ruberoid Mop 170 17. Deck: NC Incline: 1 Insulation (Optional): — Perlite, fiber glass, wood fiber, isocyanurate, urethane or perlite / isocyanurate composite. Base Sheet: — One or more layers Type G2 or G3 base sheet, hot mopped or mechanically fastened. Ply Sheet (Optional): — One or more layers Type G1, hot mopped in place. Membrane: — One layer "Ruberoid Mops 170 FR" 18. Deck: NC Incline: 1/2 Insulation (Optional): — Perlite, fiber glass, wood fiber, isocyanurate, urethane or perlite /isocyanurate composite. Base Sheet (Optional): — One or more layers Type G -2 or G -3 base sheet, hot mopped or mechanically fastened. Ply Sheet (Optional): — One or more layers Type G -1, hot mopped in place. Membrane: — One layer "Ruberoid Torch Smooth" (smooth), "Ruberoid Mop Smooth ". Membrane: — One layer "Ruberoid Mop 170 FR" (granule). 19.. Deck: NC Incline: 1/2 Insulation (Optional): — One or more layers perlite, glass fiber, isocyanurate, urethane or pexih /isocyanurate composite, any thickness. Base Sheet: — One or more plies Type G1 or G2, hot mopped or adhered with Karnak Chemical 81"� or Gibson -Homan "No. 6160" Gold applied adhesive at 1 -1/2 gal/sq. Membrane: — One layer "Ruberoid Mop 170 FR ", hot mopped or adhered with Karnak Chemical "No. 81" or Gibson -Homan "No. 6160" cold applied adhesive at 1 -1/2 gal/sq. 20. Deleted. 21. Deck: C -15/32 Incline: 1/2 rvv\7 /t lit /T NNFYT!W r. R A MFkhnwna¢e.htnnl ?name =TG... 10/22/04 HIGH VELOCITY HURRICANE ZONES — REQUIRED QWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS: • • •• ...: '•• R4402.13.1 Scope. As it pertains to the section, it is the responsibility of roofing conirUtot t0 provide tee owner with the required roofing permit, and to explain to the owner the content of the section. The provisions of Section R4402 govern the minimum requirements and standards of the industry fQ, od'ftht sys,eel in� rallations. • Additionally, the following items should be addressed as part of the agre1mIntilfetween Elie wear tie •e • contractor. The owner's initial in the designated space indicates.that the item its been nalagniel ;•; ;•; 1. Aesthetics - Workmanship: the workmanshil ?proy�s�►ors:of•SgcQen 1t• 02 are the purpose of providing that the roof system meets the, ing Cestslinryil warty instruction performance standards. Aesthetics (appearance) are not a torrsitteifftioreWith respect to workmanship provisions. Aesthetic issues such as color or architpituia3 appearance, that are not part of a zoning code, should be addressed as part of the agreement between the owner and the contractor. 2. Renailing wood decks: When replacing roofing, the existing wood roof deck have to be renailed in accordance with the current provisions of Section R4403. (The roof deck is usually concealed prior to removing the existing roof system). 3. Common roofs: Common roofs are those which have no visible delineation een neighboring units (i.e., townhouses, condominiums, etc.) In buildings with common roofs, the roofing contractor and/or owner should notify the occupants of adjacent units of roofing to be performed. 4. 1 Ail Exposed Ceiling: Exposed, open beam ceilings are where the underside of the f decking can be viewed from below. The owner may wish to maintain the architectural appearance; therefore, roofing nail penetration of the underside of the decking may not be acceptable. The provides the option of maintaining the appearance. 5. Ponding water: The current roof system and/or deck of the building may not am well and may cause water to pond (accumulate) in low -lying areas of the roof. Ponding can be an indication of structural distress and may require the review of a professional structural engineer. Ponding may shorten the life expectancy and performance of the new roofing system. Ponding conditions may not be evident until the original roofing system is removed. Ponding conditions should be corrected. Overflow scuppers (wall outlets): It is required that rainwater flow off so that roof is not overloaded from a buildup of water. Perimeter /edge wall or other roof extension may block this discharge if overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in accordance with the requirements of Sections R4402, R4403 and R4413. 7. � Ventilation: Most roof structures should have some ability to vent natural ow through the interior of the structure assembly (the building itself). The existing amount of attic ventilation shall not be reduced. It may be b neficial to consider additional venting which can result in extending the service life of oof. ntractor Signature Date