Loading...
RF-07-1670Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Inspection Date: 09/25/2007 Inspector: Grande, Claudio Owner: CAPRI, JOHN Job Address: 375 99 Street NE Miami Shores Village, FL Project: <NONE> Block: Contractor: DALEY ROOFING INC Permit Type: Roof Inspection Type: Final Roof Work Classification: Roof - New Phone Number Parcel Number 1132060135530 Lot: Phone: (305)754 -9892 Building Department Comments re roof tile roof scY 61 Passed ' / Inspector Comments 19 i S— L--------- Failed Correction Needed Re- Inspection Fee ($75) No Additional Inspections can be scheduled re- inspection fee is paid until Monday, September 24, 2007 Page 1 of 2 Miami Shores Village °�' ` Itr1 rn57 Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 BUILDING PERMIT APPLICATIO FBC 2004 Permit No. If AUG 0 8 2007 Master Permit No. 1'Is1O BY:—i Permit Type (circle): Building ,Electrical Plumbing Mechanical Owner's Name (Fee Simple Titleholder)CQt'0` L x\ i JIt Z aG IA n no- 4 XterPhone # t335 370- / 0 55 Owner's Address '? 75- RiE-9 q 6r City %14 L/?alei f hsrtj State W Zip 3'3/3 er Tenant/Lessee Name Phone # Job Address (where the work is being done) 3"7'S A/t 94 5 T City Miami Shores Village County Miami -Dade FOLIO / PARCEL # Zip 33/ 38 Is Building Historically Designated YES NO Contractor's Company Name Contractor's Address City / l/t t (10191.1 Qualifier Name --b GI. /20 - 41'L- Phone # 3DS– 794 ij% •'1 S �' aviae) State Certificate or Registration No. State Zip 33/ (0g Phone # 0 Certificate of Competency No. Architect/Engineer's Name (if applicable) Phone # Value of Work For this Permit $ lq lea 06 Square / Linear Footage Of Work: Type of Work: ❑Addition ❑Alteration [New Repair eplace ❑ Demolition Describe Work: < 12400 ^� 1-7 te; Con f2- ** ** * *** * * ** * * * * * * * **** * *, *, * * *** *, , Fees ** **4**. * * * ** *4,** * * * *** *** *** * * * * * * * ** * ** ** Submittal Fee $ Permit Fee $ . CCF $12-- CO /CC Notary $ Training/Education Fee $ 4 . J J Technology Fee $ —% „S® Spanning $ L Radon $ Bond $ Code Enforcement $ Double Fee $ Structural Review. $ Total Fee Now Due $ 0 . `jC.) DPBR $ Zoning $ See Reverse side ---> Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgag* kettles Nan4if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS. and AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged Signature Owner or Agent The foreg . ing instrument w acknowledged before me this 6' dayof 111 ,a 20 J by wbo is prersofj ly known to me or who has produced As identification and who did take an oath. NO Sign: Print My Commission Expires: * * * * * * * * * * * * * * * * * * * * * * * ** APPLICATION APPROVED BY: (Revised 02108/06) MY COMMISSION # DD 606830 EXPIRES: October 22, 2010 �I Signature - '. Contractor The foregoing instrument was acknowledged before me this 7 " dayof A fiJ 'b , 20 t`), by "--7-it/ 'lam/ y who ' persona y t me or who has produced as identification and who did take an oath. NOTARY PUBLIC: Sign: Print: My Commission Expires: * * * * * * * * * * * * * * * * * * * * * * * * * * * ** v7.72. /lay; 7 Plans Examiner Engineer Zoning NOTICE OF COMMENCEMENT A RECORDED COPY MUST BE POSTED =DEMO %TEAM& OF FIRST I< ION PERMIT NO. TM FOLIO NO. STATE OF FLORIDA: COUNTY OF MIAMI -DARE; THE UNDERSIGNED hereby giVes noffceitud improvements wIWbe made to certain real properly, and in accxadaros war Chaps713, Florida Statutes, The following informaffon is provided in this Notice of Commencement_ IIlltl# 1IIlh1rf'i1Illh111Etlill1 CFN 2007R0785933 OR Bk 25842 Ps 3337; (1Ps) RECORDED 08108/2007 11 :52.44 HARVEY RUVIN, CLERK Of COURT MIAMI-DADE COUNTY? FLORIDA LAST PAGE 1. Legal description of property and street/address: 375 it.0 iii/ n# C( :33)3i 2. Description of improvement ,2 — /7 Le- f 3. Ow ner(s) name and address: j tvv$, 411- Vi iL t i t4f,' Interest in property: Name and address of fee simple titleholder. qq ST) A4glut 1 ce :';, R 3313 J'A 4. Contractor's name and address: 4;n4) M7 £t 33Rol •5. Surety: (Payment bond required by owner from contractor, if any) Name and address: Amount of bond $ 6. Lender's name and address: h=IA 7. Persons within the state of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)7., Florida Statutes, Name and address: i 1 8. In addition to himself, Owners designates the following person(s) to receive a copy of the Lienor,'s Notice as provided in Section 713.13(1)(b), Florida Statutes. Name and address: ll 9. Expiration date of this Notice of different date is specified) Corimmencement:at�i date is 1 year from the date of recording unless a 9* t om+ ` :41.woh1, ?o i�f 2 • ° rt+� Z y. % Signature of Owner Print Owner's Name DO \I II Sworn to and subscri Notary Public Print Notary's Name d,.� • 9�'. `aodt r .' ' My r•.nmmissinn �xnirac• d lraz?-fx 63/0 r) `ao l Prepared by 2f1-Q57 ' /Q %1-41 V 41 Address: 13t A,41 i -S r /Wiwi , ,4/33 /Gok. STATE OF FLORIDA, COUNTY OF DARE 1 HEREBY CER77FY *et this is a copy of the original krttis m AO206? and Official seat HARV RUVIN, CLERK of County NOTICE OF COMMENCEMENT A RECORDED COPY MUST BE POSTED ON THE .RIB SITE AT TIME OF RRST INSPECTION PERMIT NO. TAX FOLIO NO. STATE OF FLORIDA: COUNTY OF I -DADS: THE UNDERSIGNED hereby gives notes that Imps val be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following ktomation is provided in this Notice of Commencement. II11I1 I11111I111IIIIII111II1111111II lIl IhII CFN 2007R0785933 DR Bk 25842 Ps 3337; tips} RECORDED 08/08/2007 11 :52 :44 HARVEY RUVIidr CLERK OF COURT MIAMI -DADE COUHTYr FLORIDA LAST PAGE 1. Legal description of property and street/address: 3 75 996 r 2. Description of improvement: i� °7►"I . 3. Owner(s) name and address: ctbANPr (Li tL`tANI Interest in property: �S ivC, qc Sri Munn► ��S R 33a Name and address of fee simple titleholder. /P 4. Contractor's name and address: gr4) /i iA�dvbu, J/ 33Rcf •5. Surety: (Payment bond required by owner from contractor, if any) Name and address: Amount of bond $ 6. Lender's name and address: Ni A A 7. Persons within the state of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)7., Florida Statutes, Name and address: i 8. In addition to himself, Owners designates the following person(s) to receive a copy of the Lienor's Notice as provided in Section 713.13(1 Xb), Florida Statutes. Name and address: ll 9. Expiration date of this Notice of Commencement: ,�n date is 1 year from the date of recording unless a different date is specified) f�� �'`....: r''•QG��'�. syf : o,-41 x x o 11 Z Signature of Owner ' _ - :i7 ."+ $� a523Y66 Print Owner's Name I) 1(111 + '4I:0%•2'4444w 4 Prepared by. Sworn to and subscri. j '1`L 1 y4��.`�c fit,_ `= e this i da d('�y�, i Notary Public Print Notary's Name 1► d l i My cnmmisssinn gornireaw• Address: , 13g tea, STATE OF FLORIDA, COUNTY OF DADE t HEREBY CERTIFY Uteri this Is a NA copy of the d origin ! IedlnYds on AD20 ®% WINES r, and t?Htdal Seat MARY RUVIPT, CLERK. of - 8 Co my BY AUG 0 8 2007. BY:_ % al • • •• •• • •• • ' 2 •. • • • • Page 1 of 1 • • ••• •• •• • • • High Velocity Hu i15 ne®nif Roofing Permit Appifcat%n1orin MWMI -DADE C DI iiff DEP ENT ELECTRONIC APPUCATION Master Permit No. • • • ▪ • onmation) • . • • • • • • • • No. • • Contractor's Name: f•'t. slope I— Asphaltic Shingles r Prescriptive BUR -RAS 150 • • • • • • • • ••• Address: • • • • • . • • •• • • • • • Roof Category E Mechanically Fastened Tile I— Metal PaneWShingles • • • • • • • ••• •• • • •• •• • Other: I Roof Type r New Roof rie- Roofing I- Recovering Are there Gas Vent Stacks located on the roof? r Yes 60 Low slope roof area (ft2) 1 SMortar/ I— Wood I- Repair r Maintenance If yes, what type? r Natu Roof System Information Steep Sloped area (ft.2) 1 Total (ft.T) Section B (Roof Plan) • • • • • ••• • ••• • • • • • • • • • • • • • • ••• •• • • •• • • • • ••• •• Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drat of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. Perimeter Width (a'): 1_ Comer Size (a' It a'): 1 -- Page 2 file://C:\My%20Doeuments\appendix%20e.htm 8/7/2007 'hake t\ 4 ae II GX} E WITH AI _S AND R CO BLDG DEPT _ dig - tors_ Z .. 0_, Ia. Q Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drat of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. Perimeter Width (a'): 1_ Comer Size (a' It a'): 1 -- Page 2 file://C:\My%20Doeuments\appendix%20e.htm 8/7/2007 Page 1 of 1 • • ••• • • • ... • • • • • .. • • • • • • • • • • . . . • • • • • • ••.• • • •••• • • Section D (Steep Sloped Roof System) • . • . • High Velocity Hurricane Zone Uniform Roofing Permit Application Form MIAMI -DADE COUNTY BUILDING DEPARTMENT ELECTR•ONHH AP ICOTION• • • • • - - - - - - •••• • • Section D (Steep Sloped Roof System) • . • . • • ••• . urer� Ir •• Roof System Manufad W� - - - - - - Notice of Acceptance Number: I 047 —, /• 0 S a ®S Minimum Design Wind Pressures, If Applicable (from RAS 127 or Calculations): P1: 17.10 P2• /DO OP3• Md. ter Maximum Design Wind Pressures, (From the PCA Specific system): I fte oh / Roof Slope: I 47 1i Z °/12° Roof Mean Height i ib e� Ridge Ventilation: I 0 J (� Method of Tile Attachment: . . . • • .•. .• • • • . • • • • • •.• •. Sloped System Description Deck Type: I5/8° Plywood • J Alternate Deck Type: IN /A Alternate Tile Attachment Method: Clip Spacing for Metal Roof Panels Field: I -- Perimeters: Corners: I---r Perimeter W dth: Page 4 file: / /C :\My%20Documents \appendix %20section %20d.htm Underlayment type: 114-30 AS Insulation/Fire Barrier Board: I NIA Optional Nailable Substrate: I • Fasten rs: 1 g6j8 c.elps, 'Argo Fvof- had Cap Sheet Type /Adhesive Type: I POW g 11 Cit. TO Roof Covering: Ii VEX- ir'IIr #1 .17 Li Roof Covering Attachment Method: I PO l FoptryTh Arc t Svc Drip Edge Size & Gauge:13 face 26 ga. Drip Edge Material Type: IGalvinized Metal :1 Drip Edge Fastener Type: IIVL(V- ¥efr& Hook Strip/Cleat ga. or weight I N /A 8/7/2007 Page 1 of 1 • .... • • .... •• •• • • • •• •• • ... • ..... • • • • I • • . • . • . • 15' • ...... • .... High Velocity Hurricane Zone Uniform Roofing Permit Application Form MIAMI -DADE COUNTY BUILDING DEPARTMENT ELECTFON1C APPjICATION 25' 30' .... • • Section E (Tile Calculations) .... • • .. • • • •• • • • •• ••• •• • ......... • For Moment based tile systems, chose either Method 1 or 2. Colgate th *baldes for Mr with the values from Mf. If the Mf values are greater than br'egdal to IMP' Mr values, for each aea of the roof, then the tile attachment method is acceptable. Method 1 "Moment Based Tile Calculations Per RAS 127" P 1: Lt). L x A . 2g q - Mg: 6,30 = Mr1: 6.(00 NOA Mf: gip .101 P 2: /00. 49 x A d AC - Mg: (, ..o = Mr1: 23. Of NOA Mf: $(y. L. l P 3: go, (v x A /).g9 - Mg: (. 30 = Mr1:23.0g NOA Mf: 8 , . (o Method 2 "Simplified Tile Calculation Per Table Below" Required Moment of Resistance (Mr) From the Table Below: 32.. Z NOA Mf: g(®, Lo I Mr Required Moment Resistance* Mean Roof Height in Feet 15' 20' 25' 30' 40' Roof Slope 1 w 1 1 1 1 2:12 34.4 36.5 38.2 39.7 42.2 3:12 32.2 34.4 36.0 37.4 39.8 4:12 30.4 32.2 33.8 35.1 37.3 5:12 28.4 30.1 31.6 32.8 34.9 6:12 26.4 28.0 29.4 30.5 32.4 7:12 24.4 25.9 27.1 28.2 30.0 *This Table must be used in conjunction with a list of moment based tile systems endorsed by the Broward county Board of Rules and Appeals. Page 5 http: / /www.miamidade.gov/ building /roofing, permiting/section a 3.htm 8/7/2007 MIAM$D BUILDING CODE COMPLIANCE OFFICE (BCCO) PRODUCT CONTROL DIVISION NOTICE OF ACCEPTANCE (NOA) Monier ILifetile, LLC 135 NW 20"' Street Boca Raton, FL 33431 • • ••• • • • ••• •• •• • • • •• •• • • • • • • • • • • • • • • ••• • • • • • • • • • • • • • • ••• • • • • ••• MIAMI -DADE COUNTY, FLORIDA • • • i1ISTRO�•ADS1wLAGLSIt &J1f 1NG • • . • . • . • . • • 1�0 6hFLA «EE' SUWE 1603 • • • • SfORIDrA 331%0 -1563 (305) 375 -2101 FAX (305) 375-2908 •• • • • •• ••• •• • • • • • • • • • •• • • • • • ••• •• SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by Miami -Dade County Product Control Division and accepted by the Board of Rules and Appeals (BORA) to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Division that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Villa, Roll, and Capri Concrete Roof Tile LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA consists of pages 1 through 7. The submitted documentation was reviewed by Frank Zuloaga, RRC NOA No. 02- 1205.05 Expiration Date: 12/16/07 Approval Date: 01/02/03 Page 1 of 7 ROOFING ASSEMBLY APPROVAL Category: Roofing Sub- Category: Low Profile Roofing Tiles Material: Concrete 1. SCOPE This renews a system using Monier Lifetile Villa, Roll, and Capri Concrete Roof Tile, as manufactured Monier Lifetile LLC and described in Section 2 of this Notice of Acceptance. For locations where the pressure requirements, as determined by applicable Building Code does not exceed the design pressure values obtained by calculations in compliance with RAS 127 using the values listed in section 4 herein. The attachment calculations shall be done as a moment based • • ••. • • • ••• •• •• • • • •• •• • • • • • • • • • • • • • • ••• • • • • • • • • • • • • • ••• • • • • ••• • • • • •.• •.•. .••• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •• • • • •• •.• •• • • • • • • • • • •• • • • • • ••• •• 2. PRODUCT DESCRIPTION Manufactured by Test licant Dimensions Specifications Monier Lifetile LLC Villa & Roll Monier Lifeitile LLC Capri Tile Trim Pieces 1 =16% :" PA112 w= 13" Y2" thick L =17" PA112 W =12 3/8" Y2" thick 1= varies w = varies varying thickness 2.1 SUBMITTED EVIDENCE: Test Aeencv Redland Technologies Redland Technologies Redland Technologies PA 112 Test Identifier 7161 -03 Appendix III 7161 -03 Appendix II P0402 The Center for Applied 94-060B Engineering, Inc. The Center for Applied 94-084 En ',g, Inc. No/. r/,E,t\ Product Description Low profile, interlocking, high pressure extruded concrete roof tile equipped with one nail hole and double roll ribs. For direct deck or battened nail -on, mortar or adhesive set applications. Low profile, interlocking, high pressure extruded concrete roof tile equipped with one nail hole and double roll nbs. For direct deck or battened nail -on, mortar or adhesive set applications. Accessory trim, concrete roof pieces for use at hips, rakes, ridges and valley terminations. Manufactured for each tile profile. Test Name/Renort Date Static Uplift Testing Dec. 1991 PA 102 & PA 102(A) Wind Tunnel Testing Dec. 1991 PA 108 (Nail -On) Withdrawal Resistance Testing of Sept. 1993 screw vs. smooth shank nails Static Uplift Testing March, 1994 PA 101 (Adhesive Set) Static Uplift Testing May 1994 PA 101 (Mortar Set) NOA No.: 02- 1205.05 Expiration Date: 12/16/07 Approval Date: 01/02/03 Page 2 of 7 Test A2encv Redland Teclmologies Redland Technologies Professional Service Industries, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. Celotex Corporation Testing Services Walker Engineering, Inc. Walker Engineering, Inc. Walker Engineering, Inc. Walker Engineering, Inc. Walker Engineering, Inc. Walker Engineering, Inc. Walker Engineering, Inc. Test Identifier, P0631 -01 Letter Dated Aug. 1, 1994 224 -47099 25- 7094 -1 25 -7094-7 25- 7094 -4 Project No. 307025 Test #MDC -760 25- 7183 -1 25- 7183 -2 25 -72142 25- 7214 -6 528454-2 -1 520109 -2 Calculations Evaluation Calculations Evaluation Calculations Evaluation Calculations Evaluation Calculations Evaluation Calculations Evaluation Calculations • • ••• • •• •• • • • • • • • • • • • • ••• • • • • • • • ••• • • • • • •• • • • • • • • • • ••• Test NameiRenr t • -r ... • • • July 191)4.' ' • • ••• • • • Aug. 1994 •••• •. Wind Tun$el:Tesiing PA 108 (Mertar Set) ' • Wind Tunnel Testing PA 108 (NailrQn) • • Physical Properties • • • PA Static Uplift Testing PA 102 (4" Headlap, Nails, Direct Deck, New Construction)❑ Static Uplift Testing PA 102 (4" Headlap, Nails, Battens) Static Uplift Testing PA 102 (4" Headlap, Nails, Direct Deck, Recover/Reroof) Wind Driven Rate PA 100 Static Uplift Testing PA 102 (2 Quik-Drive Screws, Direct Deck) Static Uplift Testing PA 102 (2 Quik-Drive Screws, Battens) Static Uplift Testing PA 102 (1 Quilt-Drive Screw, Direct Deck) (1 Quik-Drive Screw, Battens) Static Uplift Testing PA 101 Aerodynamic Multiplier 25 -7183 25 -7094 25 -7496 25 -7584 25- 7804b -8 25 -7804-4 & 5 25- 7848 -6 Aerodynamic Multipliers •• ••• •• • 4 19944 • • • • Oct. 1994 Oct. 1994 Oct. 1994 Oct. 1994 Feb. 1995 Feb. 1995 March, 1995 Sep. 1998 Dec. 1998 March 1999 March 1995 February 1996 April 1996 December 1996 April 1999 Two Patty Adhesive Set System April 1999 NOA No.: 02- 1205.05 Expiration Date: 12/16/07 Approval Date: 01/02/03 Page 3 of 7 3. LIMITATIONS • • ••• • • • ••• •• •• • • • •• •• • • • • • • • • • • • • • • ••• • • • • • • • • • • • • • ••• • • • • ••• • • • • • ••• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •••• ••• •••• •••• • ••• 3.1 Fire classification is not part of this acceptance. • • 3.2 For mortar or adhesive set tile applications, a static field uplift test shall be performed in accordance with RAS 106. • • • • • • • • • . • • 3.3 Applicant shall retain the services of a Miami -Dade County C•atifigd;Lajbgra tperterjn quarterly test in accordance with TAS 112, appendix `A'. Sual, test 1101 Ike )uugyttt4 to the Building Code Compliance Office for review. 3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed section 4.1 herein. 3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature. 3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with applicable building code. 4. INSTALLATION 4.1 Monier Lifetile Villa, Roll, and Capri Concrete Roof Tile and its components shall be installed in strict compliance with Roofing Application Standard RAS 118, RAS 119, and RAS 120. 4.2 Data For Attachment Calculations Table 1: Average Weight (W) and Dimensions (I x w ) Tile Profile Weight -W (Ibf) Length4 (ft) Width -w (ft) Monier Lifetile Villa and Roll Tile 9.1 1.33 1.08 Monier L'Ufetlle Capri Tile 9.51 1.42 1.03 Table 2: Aerodynamic Multipliers - A. ft3) Tile Profile 7l (ft3) X (ft3 Batten Application Direct Deck Application Monier Lifetile Villa, Roll and Capri Tile _ 0.267 0.289 Table 3: Restoring Moments due to Gravity - MA (ft -Ibf) Tile Profile 3 ":12" 4 ":12" 5 ":12" 6 ":12" 7 ":12" greater Battens or Direct Deck Monier Ufetlle Villa, Roll, and Capri Tile Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck 5.57 6.30 5.48 6.18 5.37 6.05 _ 5.24 5.90 5.09 5.73 NOA No.: 02- 1205.05 Expiration Date: 12/16/07 Approval Date: 01/02/03 Page 4 of 7 • • ••• • • • ••• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • ••• • • • • • • • • • • • • • • • • • ••• • • • • • • • •• • • Table 4: Attachment Resistance Expressed as a MQnje ;M M, gitabf). ' . : : • • for Nall -On Systems • • • • • • , • • • • _ • • • • _ • • • • Tile Profile Fastener Type Direct Deck (min 15132" plywood) Direct Deck (min. 19132" plywJ�: :: • • • • 1 • Battens - • • • • : : : . '. •• • • Monier Lifetlle Villa, Rod, and Capri Tile 2 -10d Ring Shank Nails 27.8 V.4 ' • ' • • 2855 • • 1 -10d Smooth or Screw Shank Nail 8.8 11.8 4.1 2 -10d Smooth or Screw Shank Nails 16.4 21.9 7.1 1 #8 Screw 25.8 25.8 22.9 2 #8 Screw 47.1 47.1 49.1 1 -10d Smooth or Screw Shank Nall ( Feld Clip) 24.3 24.3 24.2 1 -10d Smooth or Screw Shank Nail (Eave Clip) 19.0 19.0 ° 22.1 2 -10d Smooth or Screw Shank Nails (Field Clip) 35.5 35.5 34.8 2 -10d Smooth or Screw Shank Nails (Eave Clip) 31.9 31.9 32.2 2 -10d Ring Shank Nails' 43.0 67.5 50.9 1 Installation with a 41 the headlap and fastemers are loci a min. of 2W from head of tile. Table 5: Attachment Resistance Expressed as a Moment Mr (ft -Ibf) for Two Patty Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Monier Ufetile Villa, Roll, and Capri Tile Adhesive 26.1' 2 See manufactures component approval for installation requirements. 3 Flexible Products Company TileBond Average weight per patty 11.4 grams. Polyfoam Product, Inc. Average weight per patty 8 grams. Table 5A: Attachment Resistance Expressed as a Moment - Mt (ft -Ibf) for Single Patty Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Monier Lifetle Villa, Roll, and Capri Tile Polyfoam PolyPron" 86.61" Polyfoam PolyProT" 45.5° 4 Large paddy placement of 54grams of PolyPro'". 5 Medium paddy placement of 24grams of PoIyPro'". NOA No.: 02- 1205.05 Expiration Date: 12/16/07 Approval Date: 01/02/03 Page 5 of 7 • •• • • • • • • ••• • • • • • • • • • • • • • • • • • • • • • • • • ••. • • • • • • • • ••• • • • • • • • Table 5B: Attachment Resistance Expressed as a Mbrilehi : d1r�Ft�Jbf�,' . for Mortar Set Systems • _ • • • ... • : •: • • • • Tile Tile _ Attachment ' • Profile Application Resistance Monier Lifetile Villa, Roll, and ^,.�{T Capri Tile Mortar Set' • • • • : : ati 60 :' • ••• • • • • : • •• • .' • • {t� • • • • • ■ • • • •• 5. LABELING All tiles shall bear the imprint or identifiable marling of the manufacturer's name or logo, or following statement: "Miami Dade County Product Control Approved ". 6. BUILDING PERMIT REQUIREMENTS 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance. 6.1.2 Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this system. PROFILE DRAWINGS MONIER LIFETILE VILLA CONCRETE RooF TILE NOA No.: 02- 1205.05 Expiration Date: 12/16/07 Approval Date: 01/02/03 Page 6 of 7 • •• • • • • • • • • • • • • ••• • • •• •• • • • • • • • ••• • • • • • • • • • • • • • ••• • • • • ••• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •• • • • •• ••• •• • • • • • • • • • •• • • • • • ••• •• MONIER LIFETILE ROLL CONCRETE ROOF TILE MONIER LIFETILE CAPRI CONCRETE ROOF TILE END OF THIS ACCEPTANCE NOA No.: 02- 1205.05 Expiration Date: 12/16/07 Approval Date: 01/02/03 Page 7 of 7 MIAMI•DADE BUILDING CODE COMPLIANCE OFFICE (BCCO) PRODUCT CONTROL DIVISION NOTICE OF ACCEPTANCE (NOA) Polyglass USA Inc. 150 Lyon Drive Fernley, NV 89408 • • • • • • • • • ••• • • •• •• • • • • • • • ••• • • • • • • • • • • • • • ••• • MIAMI-DADE COUNTY, FLORIDA METAO+D'ADF FLAGi.g1i JIUTLQEsip • • 140 WESI:FI�AFI�ER SiiRlIET:SUI' F.:16D3 •' • MFAMI, F%ettdit3130e 1.563; (305) 375.2901 FAX (305) 375 -2908 •• • • • •• •• .• • • • • • •• • • • • • • ••• •• • SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by Miami -Dade County Product Control Division and accepted by the Board of Rules and Appeals (BORA) to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Division that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Polystick P, Basik, IR/IRX, TU, TU Plus and MU Underlayments LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA No. 06- 0424.03 and consists of pages 1 through 6. The submitted documentation was reviewed by Jorge L. Acebo. NOA No 06- 0505.01 Expiration Date: 09 /13/11 Approval Date: 11/30/06 Page 1 of 6 ROOFING COMPONENT APPROVAL Category: Sub- Cateeorv: Material: Roofing Underlayment SBS , APP Self- Adhering Modified Bitumgf • • • • ..• • • • .•• •. •• • • • • • • • • • • • • • • • • • • • • • • • ••. • • • • • • • • • • • • • • ••• • • • • ••• • • • • • ... • • • • • • • • • • • • • • • • • • • • • • •••. • • • • • • • •••• •••. .• • • • • • • • PRODUCTS DESCRIPTION: Pr uct Dimensions Polystick P underlayment Polystick Basik underlayment Polystick IR/IRX underlayment Polystick TU underlayment Polystick TU Plus underlayment (Facer of Membrane Labeled in Orange or Black Ink) Polystick MU underlayment Roll: 75' x 3' 40 mils thick Roll: 65'8" x 3'3-34" 60 mils thick Roll: 65'8" x 3'3-3/8" 80 mils thick Roll: 32'10" x 3'33/8" 100 mils thick Roll: 65'8" x 3'3-3/8" 80 mils thick Roll: 65'8" x 3'3 -3 /8" 80 mils thick Test Specification ASTM D 1970 ASTM D 1970 TAS 103 and ASTM D 1970 TAS 103 and ASTM D 1970 TAS 103 and ASTM D 1970 TAS 103 and ASTM D 1970 •• •. ••.• • •. •• •• oo •• • •• • • • • • Product Description ••• •• • .• • • • • ••• •• A polyethylene top surface, self - adhering, SBS polymer modified bituminous sheet material for use as an underlayment in sloped roof assemblies. Designed as an ice & rain shield. A homogeneous, rubberized asphalt waterproofing membrane, glass fiber reinforced with polyolefmic film on the upper surface for use an underlayment for metal roofing. A fine granular /sand top surface self - adhering, APP polymer modified, fiberglass reinforced, bituminous sheet material for use as an underlayment in sloped roof assemblies. Designed as an ice & rain shield and as a flat roof tile underlayment. .A heavy granuled surface self adhering, APP polymer modified, fiberglass or polyester reinforced, bituminous sheet material for use as anunderlayment in sloped roof assemblies. Designed as a a roof tile underlayment. A non - wicking fabric surfaced, self - adhering, APP polymer modified, fiberglass reinforced with a high strength polyester fabric, bituminous sheet material for use an an underlayment in sloped roof assemblies. Designed as a metal roofing and roof tile underlayment. A non - wicking fabric surfaced, self - adhering, APP polymer modified, fiberglass reinforced, bituminous sheet material for use an an underlayment in sloped roof assemblies. Designed as a metal roofing and roof tile underlayment. NOA No 06- 0505.01 Expiration Date: 09 /13/11 Approval Date: 11/30/06 Page 2 of 6 EVIDENCE SUBMTITED: Test Agency Test Identifier Exterior Research & Design, LLC #11756.04.01 -1 #11756.08.01 -1 #02202.08.05 PRI Asphalt Technologies PRI01111 PUSA - 005 -02 -01 PUSA - 018 -02 -01 PUSA- 035 -02 -01 PUSA - 033 -02 -01 • • • • • • • • • Test NameIR*ubrt •. • • . • ••• • • • ••• • • • •• •• • • • • • • • • • ••• • • • • • • . • • ••• • • • • ••• • • • • b ale. • • •-.•— • • • . • • • TAS 103 ASTM D 1970 TAS 103 ,•• ASTM D 4977' ASTM D 4975'• • • ASTM D 2523 TAS 103 ASTM D 1970 ••• • • • • 04/27 /01 • • • 08/14/01 • 0$A29/95 • • • •.•.. • • • Oi�IJr IQ2 • • 01/ 1/O2. • •.' 07/14/03 09/29/06 01/12/06 INSTALLATION PROCEDURES: Deck Type 1: Wood, non - insulated, new construction Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626 or Polyprotector UDL or Polyprotector UDL AS. Fastening: Nails and tin caps 12" grid, 6" o.c. at laps. (for base sheet only) Membrane: Polystick membranes self - adhered. Surfacing: None 1. All nails in the deck shall be carefully checked for protruding heads. Re- fasten any loose decking panels, and sweep the deck thoroughly to remove any dust and debris prior to application. 2. Place the underlayment over metal drip edge in accordance with RAS 111. 3. Place the first course of membrane parallel to the eave, rolling the membrane to obtain maximum contact. Remove the release film as the membrane is applied. . All side laps shall be a minimum of 3 -'A" and end laps shall be a minimum of 6." Roll the membrane into place after removing the release strip. Vertical strapping of the roof with Polystick is acceptable. Membrane shall be back nailed in accordance with applicable building code. 4. When applying the membrane in the valley, start at the low point and work to the high point, rolling the membrane from the center outward in both directions. S. For ridge applications, center the membrane and roll from the center outward in both directions. 6. Roll or broom the entire membrane surface so as to have full contact with the surface, giving special attention to lap areas. Polystick TU and TU Plus shall not be left exposed as a temporary roof for longer than 180 days after application. Polyglass reserves the right to revise or alter product exposure times; not to exceed the preceeding maximum time limitations. 7. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control Notice of Acceptance. 8. All protrusions or drains shall be initially taped with a 6" piece of underlayment. The flashing tape shall be pressed in place and formed around the protrusion to ensure a tight fit. A second layer of Polystick shall be applied over the underlayment. NOA No 06- 0505.01 Expiration Date: 09 /13/11 Approval Date: 11/30/06 Page 3 of 6 GENERAL LIMITATTIONS: 1. Fire classification is not part of this acceptance. 2. Polystick P, Basik and IRIIRX may be used in asphaltic shingles, wood•shakes, and shjpglesy ppn- • . structural metal roofing, and quarry slate roof assemblies. Polystick P end > �akeh�llh b 1psed. as roof tile underlayment. • • • • • 3. Deck requirements shall be in compliance with applicable building code. 4. Polystick membranes shall be applied to a smooth, clean and dry surface. The deck shall be free of irregularities. 5. Polystick membranes shall not be adhered directly over a pre - existing roof membrane as a recover system. 6. Polystick P and Basik shall not be left exposed as a temporary roof for longer than 30 days after application. Polystick IIR/IRX, or MU shall not be left exposed as a temporary roof for longer than 90 days after application. Polystick TU and TU Plus shall not be left exposed as a temporary roof for longer than 180 days after application. Polyglass reserves the right to revise or alter product exposure times; not to exceed the preceeding maximum time limitations. 7. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 913 -72 of the Florida Administrative Code. 8. In roof tile application, data for the attachment resistance of roof tiles shall be as set forth in the roof tile manufacturer's Notice. Polystick TU, TU Plus and MU may be used in both adhesive set and mechanically fastened roof tile applications. Polystick IRRJIRX is limited to mechanically fastened roof tile applications. The maximum roof slope for use as roof tile underlayment for (direct -to -deck) tile assemblies shall be as described below: • • ••• •• •• • • • • • • • • • • • • • ••• • • • • • • • • • • • • • • • • • • • • • • ••• • • •• •• • • • • • • • ••• • • • • • • • • • • • • ••• • • • • • • • • • • • • • • • • • • • • • ••• • • • • • • • • • • • • • • • Tile Profile Polystick LR/IRX Polystick MU Polystick TU, TU Plus Flat Tile 5:12 No limitation No limitation Profiled Tile Prohibited 5:12 No limitation The above slope limitations can be exceeded only by using battens and counter battens in accordance with the Approved Tile System Notice of Acceptance and applicable Florida Building Code requirements. 9. Care should be taken during the loading procedure to keep foot traffic to a minimum and to avoid dropping of tile directly on the underlayment. Refer to Polyglass Tile loading detail for loading procedure. 6 Roofing Tiles (6 Max. Per Stock) 12 NOA No 06- 0505.01 Expiration Date: 09/13/11 Approval Date: 11/30/06 Page 4 of 6 • • ••• • • • ••• •• •• • • • •• •• • • • • • • • • • • • • • • ••• • • • • • ••• • • • • ••• GENERAL LIMITATTIONS: (CONTHVUED) . ... • •10. Refer to prepared roofing system Product Control Notice of Acceptance fpt Jistecf a proagl ®fli8 • • • product with specific prepared roofing products. Polystick P, BasikA TU,•IP.1 Pips & NY may be used with any approved roof covering Notice of Acceptance listing Polystick P, Basik, IR/MX, TU, TU Plus & MU as a component part of an assembly in the nottc ,of Acceptance. . • If Polystick P, Basik, IR/IRX, TU, TU Plus & MU is not listed, a request�ayigntdi tg t1�e • • • Authority Having Jurisdiction (AHJ) or the Miami -Dade County Product:C�lnCroj Dtpntt for approval provided that appropriate documentation is provided to detail compatibility Mite • • • • products, wind uplift resistance, and fire testing results. LABELING: All membranes shall bear the imprint or identifiable marking of the manufacturer's name or logo, the Miami-Dade County logo or the following statement: "Miami -Dade County Product Control Approved ". BUILDING PERIVIIT REQUIREMENTS: Application for building permit shall be accompanied by copies of the following: 1. This Notice of Acceptance. 2. Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this materials. POLYGLASS GENERAL APPLICATION GUIDELINES FOR POLYSTICK MEMBRANES: 1. Polyglass does accept the direct application of Polystick underlayment membranes to wood decks. Installers are cautioned to refer to applicable local building codes prior to direct deck installation to ensure this is acceptable. Please also refer to applicable Product Data Sheets of the corresponding products. 2. All rolls, with the exception of Polystick TU Plus and Polystick MU should be back - nailed in selvage edge seam as per Polyglass Back Nailing Guide. Nails shall be, 11 gauge ring shank type, applied with a minimum I" metal disk as required in Dade County or simplex type nail as otherwise allowable in other regions, at a minimum rate of 12" o.c. Polystick TU Plus and Polystick MU should be back nailed in designated area marked "nail area, area pare clavar" on the face of membrane, with the above stated nails and/or disks. The head lap membrane is to cover the area being back - nailed. (Please refer to applicable local building codes prior to installation.) 3. All seal lap seams (selvage laps) must be rolled with a hand roller to ensure full contact. 4. All fabric over fabric; and granule over granule end laps, shall have a 6" wide, uniform layer of Polyglass 2000 MB Plus trowel grade or other approved premium SBS modified trowel grade mastic, applied in between the application of the lap. The use of mastic between the laps does not apply to Polystick Basik. 5. A maximum of 6 tiles per stack are allowed when loading tile on the underlayments. Refer to the Polyglass Tile Loading Guidelines. 6. Battens and/or Counter - battens, as required by the tile manufacturers NOA' s, must be used on all projects for pitch/slopes of 7"/12" or greater. It is suggested that on pitch/slopes in excess of 6 1/4 "/12 ", precautions should be taken, such as the use of battens to prevent tile sliding during the loading process. NOA No 06- 0505.01 Expiration Date: 09/13/11 Approval Date: 11/30/06 Page 5 of 6 • • ••• • • • ••• •• •• • • • •• •• • • • • • • • • • • • • • • • • ••• • • • • • • • ••• • • • • ••• 7. Minimum cure time after membrane installation & before loading of o ing tiles�is•Furt}� -Eiglif . • • (48)Hours. ••••• ••••• •••• • 8. Polystick TU Plus, Polystick MU may not be used in any exposed application such as crickets, • • exposed valleys, or exposed roof to wall details. •• • • • •• ••• • 9. Repair of Polystick membranes is to be accomplished by applying PolyglasL2Q0fPjus'rowgl . Grade Mastic or an approved premium SBS modified trowel grade m# is t&e1r4a rilfae4i of repair, followed by a patch of the Polystick material of like kind should be set anciharid kl?ed'inf • place over the area needing such repair. Patching membrane shall be a minimum of 6 inches in either direction. The repair should be installed in such a way so that water will run parallel to or over the top of all laps of the patch. 10. All self- adhered membranes must be rolled to ensure full contact with approved substrates. Polyglass requires a minimum of 40 lbs for a weighted roller for the rolling of the field membrane. Hand rollers are acceptable for rolling of patches or small areas of the roof. 11. All approved substrates should be dry, clean and properly prepared, before any application of Polystick membranes commences. An approved substrate technical bulletin can be furnished upon request. It is recommended to refer to applicable building codes prior to installation to verify acceptable substrates. 12. The Polyglass Miami -Dade Notice of Acceptance (NOA) approval for Polystick membranes and PolyProtector UDL can be furnished upon request by our Technical Services Department by calling 1 (800) 894 -4563. 13. Polyglass offers a 10 year Limited Material Warranty on all properly installed Polystick self - adhered underlayments. Warranty must be requested and registered by Polyglass to be in force. 14. Questions in regards to the application of Polyglass products should be directed to our Technical Services Department at 1 (800) 894 -4563. 15. Polyglass recommends that applicators follow good roofing practices and applicable procedures as outlined by the National Roofing Contractors Association (NRCA). PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF SPECIFIC APPLICATIONS. LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS AND RECOMMENDATIONS. END OF THIS ACCEPTANCE NOA No 06-0505.01 Expiration Date: 09 /13/11 Approval Date: 11/30/06 Page 6 of 6 M1AMIDADE BUILDING CODE COMPLIANCE OFFICE (BCCO) PRODUCT CONTROL DIVISION NOTICE OF ACCEPTANCE (NOA) Polyfoam Products, Inc 11715 Boudreaux Road Tomball, TX 77375 • • ••• • • • ••• • • •• • • • • •• •• • • • • • • • • • • • • • • • • • • • • • • • • • ••• • • • • • • • • • • • • • • • • ••• • • • • ••• MIAMI -DARE COUNT(, FLORIDA • • • • • • M 0•IDADE PJ43 FJ'BUILDING • • W0•WES1' 12,I GPER StRtla, SUITE 1603 • • • • • • • MIAMI, FI VRIf)A 33130-1563 (305) 375 -2901 FAX (305) 375 -2908 •• • • • •• ••• •• •• • • • • • • • • • • • • • • • • • SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by the BCCO and accepted by the Building Code and Product Review Committee to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The BCCO (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AIIJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BCCO reserves the right to revoke this acceptance, if it is determined by BCCO that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Polypro® AH160 RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA No.01- 0521.02 and consists of pages 1 through 7 The submitted documentation was reviewed by Jytrge L. Acebo. NOA No.: 06-0201.02 Expiration Date: 05/10/11 Approval Date: 04/13/06 Page I of 7 ROOFING ASSEMBLY APPROVAL: Category: Roofing Sub Category: Roof tale adhesive Materials: Polyurethane SCOPE: • •• •• • • • • • • • • • • • • • • ••• • • •• •• • • • • • • • ••• • • • • • • • • • • • • • • • • • • ••• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •• • • ••• • •• • • •• • • • •• ••• •• • • • • • This approves Polypro® A11160 as manufactured by Polyfoam Products, %Im. as descilbed fn Section 2 of this Notice of Acceptance. For the locations where the design pressure requirements, as determined by applicable building code, does not exceed the design pressure values obtained by calculations in compliance with Roofing Application Standard RAS 127, for use with approved flat, low, and high profile roof tiles system using Polypro® All 160. Where the attachment calculations are done as a moment based system for single patty placement, and as an uplift based system for double patty systems • PRODUCTS MANUFACTURED BY APPLICANT: Product Dimensions Test Specifications Polypro® A11160 N/A TAS 101 Foampro® RTF1000 N/A ProPack® 30 & 100 N/A Product Description Two component polyurethane foam adhesive Dispensing Equipment Dispensing Equipment PRODUCTS MANUFACTURED BY OTHERS: Any Miami Dade County Product Control Accepted Roof Tile Assembly having a current NOA which list moment resistance values with the use of Polypro A11160 roof tile adhesive. PHYSICAL PROPERTIES: Property Density Compressive Strength Tensile Strength Water Absorption Moisture Vapor Transmission Dimensional Stability Closed Cell Content Test ASTM D 1 622 ASTM D 1621 ASTM D 1623 ASTM D 2127 ASTME96 ASTM D 2126 ASTM D 2856 Results 1.61bs. /f1.' 18 PSI Parallel to rise 12 PSI Perpendicular to rise 28 PSI Parallel to rise 0.08 LbsJFt2 3.1 Perm / Inch +0.07% Volume Change @ -40° F., 2 weeks +6.0% Volume Change @158°F., 100% Humidity, 2 weeks 86% Note: The physical properties listed above are presented as typical average values as determined by accepted ASTM test methods and are subject to normal manufacturing variation. NOA No.: 06-0201.02 Expiration Date: 05/10/11 Approval Date: 04 /13/06 Page 2 of 7 EVIDENCE SUBMITTED: Test Agency Center for Applied Engineering Miles Laboratories Polymers Division Ramtech Laboratories, Inc. Southwest Research Institute Trinity Engineering Celotex Corp. Testing Services LIMITATIONS: 1. Test Identifier #94 -060 257818 -1PA 25- 7438 -3 25- 7438 -4 25- 7438 -7 25 -7492 NB- 589 -631 9637 -92 01- 6743 -011 01- 6739- 062b[1] 7050.02.96 -1 528454 -2 -1 528454 -9 -1 528454 -10 -1 520109 -1 520109 -2 520109 -3 520109 -6 520109 -7 520191 -1 520109 -2 -1 • .. • • • • • • •.. • • • .•. • • • • • •. • • • • • • • • • .•• • • • • • • • • • • ... • • • • • • .. • • • •.•. •. • • • • • . . • • •.•• .... Tess•1'ane/Repert • • • TAS 101 04/08/94 T4$ ,0J. • •. ••42 /1696 S&ED 1 .43 • •.10125(95 • SS'1D 1.1 - ;3 ••11/02/95 SSTD 11 -93 12/12/95 ASTM D 1623 02/01/94 • ..• • • • • • . • • • . . 'Date ASTM E 108 ASTM E 108 ASTM F. 84 TAS 114 TAS 101 TAS 101 TAS 101 04/30/93 11/16/94 01/16/95 03/14/96 10/23/98 12/28/98 03/02/99 Fire classification is not part of this acceptance. Refer to the Prepared Roof Tile Assembly for fire rating. 2. Polypro® AH160 shall solely be used with flat, low, & high tile profiles. 3. Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120. 4. Roof Tile manufactures acquiring acceptance for the use of Polypro® AH160 roof the adhesive with their tile assemblies shall test in accordance with TAS 101. 5. Roof Tile manufactures acquiring acceptance for the use of HANDI =STICK roof tile adhesive with their tile assemblies shall test in accordance with TAS 101 with section 10.4 as modified herein. / F F'= ;2' MS NOA No.: 96- 0201.02 Expiration Date: 05/10/11 Approval Date: 04/13/06 Page 3 of 7 INSTALLATION: • •. • • • • • • ••• • • • • • • • • •• •• • • • • • • • ••• • • • • • • • • • • • ••• • • • • • • • • • • • • • ••• • • • • •••.• • •. • 1. Polypro® AH160 may be used with any roof tile assembly $ad ing'a.ctfrrint:VQ , that3isss uplift resistance values with the use of Polypro® AH160. • • • 2. Polypro® A11160 shall be applied in compliance with the Component Application section and the corresponding Placement Details noted herein. The roof tile assgally;s adhesive attachment with the use of Polypro® AH160 shall provide sufficient attachment tesittallat elptegieaes an•uplift based system, to meet or exceed the uplift resistance determined it nphnceFwithi 4 -Dade County Roofing Application Standards RAS 127. The adhesive attachment data is noted in the roof tile assembly NOA 3. Polypro® AH160 roof tile adhesive and its components shall be installed in accordance with Roofing Application Standard RAS 120, and Polyfoam Products, Inc. Polypro® A11160 Operating Instruction and Maintenance Booklet. 4. Installation must be by a Factory Trained 'Qualified Applicator' approved and licensed by Polyfoam Products, Inc. Polyfoam Products Inc. shall supply a list of approved applicators to the authority having jurisdiction. 5. Calibration of the Foampro® dispensing equipment is required before application of any adhesive. The mix ratio between the "A" component and the "B" component shalt be maintained between 1.0- 1.15 (A): 1.0 (B). The dispense timer shall be set to deliver 0.0175 to 0.15 pounds per file as determined at calibration. No other settings shall be approved. 6. Polypro® AH160 shall be applied with Foampro RTF1000 or ProPack® 30 & 100 dispensing equipment only. 7. Polypro® AH160 shall not be exposed permanently to sunlight. 8. Tiles must be adhered in freshly applied adhesive. Tile must be set within 2 to 3 minutes after Polypro® AH160 has been dispensed 9. Polyproo AH160 placement and minimum patty weight shall be in accordance with the Placement Details' herein. Each generic tile profile requires the specific placement noted herein. Table 1: Adhesive Placement For Each Generic Tile Profile Tile Profile Placement Detail Single Paddy Weight Min. (grams) Two Paddy Weight per paddy Min. (grams) Fiat, Low, High Profiles #1 35 N/A High Profile (2 Piece Barrel) #1 17 /side on cap and 34 /pan 24 N/A N/A Flat, Low, High Profiles 1 #2 Flat, Low, High Profiles #3 8 LABELING: All Polypro® AH160 containers shall comply with the Standard Conditions listed herein. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or applicable building code in order to properly evaluate the installation of this system. NOA No.: 06- 0201.02 Expiration Date: 05 /10 /11 Approval Date: 04/13/06 Page4of7 • • ••• • • • .•• •• •. • • • • • • • • • • • • • • • • • • • • • • • • • • • •. .0 • • • • • • • • • • • • • • • • • ••• • • • • ••• ADHESIVE PLACEMENT DETAIL 1 SINGLE PATTY • • • ••• •••• ••.• •• • • • • • • • • • • • • • • • • • • • • •••• • • • •••• • • • • • • • • • • • • • NOA No.: 06- 0201.02 Expiration Date: 05/10/11 Approval Date: 04/13/06 Page 5 of 7 • • ••• • • • ••• •• •• • • • •• •• • • • • • • • • • • • • • • ••• • • • • • • • • • • • • • ••• 1 • • • ••• ADHESIVE PLACEMENT DETAIL 2 • • • • • • • SINGLE PATTY • • • • ▪ • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •• •.• • •• ••• •• • • • • • • • • • • • • • • • • • • • • 1_• • • • • NOA No.: 06- 0201.02 Expiration Date: 05 /10 /11 Approval Date: 04/13/06 Page 6 of 7 • • ••• • • • •.e •• •• • • • •• •• • • • • • • • • • • • • • • ••• • • • • • • • • • • • • • ••• 1 • • • ••• ADHESIVE PLACEMENT DETAIL 3 . • • ••• DOUBLE PATTY • • • • • • • • ' • • • • • • • • • • • • . • • • • •••• •••• ••• • • • • • • • SIngls Ps* on top of We END OF THIS ACCEPTANCE NOA No.: 06- 0201.02 Expiration Date: 05 /10 /11 Approval Date: 04/13/06 Page 7 of 7 • • ••• • •\ • ••• •• •• • • • •• •• • • • • • • • • • • • • • • ••• • • • • • • • • • • • • • ••• • • • • ••• SECTION 4524 • • • • • • HIGH VELOCITY HURRICANE ZONES REQUIRED OWNERS 149TIFICATIbli Flint RODF216G CONSIDERATIONS se. • ' ' 1524.1 As ft pertains to this section, it is the responsibility of the roofing contractor to provide the owner with the required rooting permit, and to explain to the owner the content of this retigri.:Tbe,protipieltteat Chapter 15 of the Florida Building Code, Building govern the minimum requirements wig fifiagdtclp §t,flut Muster for roofing system installations. Additionally, the following items should be addresssigoas grtttif'thg Etrgggtejtt between the owner and the contractor. The owner's ktitial in the adjacent box indicates that the item has been explained. &IL 1. Aesthetics- Workmanship: The workmanship provisions of Chapter 15 (High Velocity Hurricane Zone) are for the purpose of providing that the roofing system meets the wind resistance and water intrusion performance standards. Aesthetics (appearance) issues are not a consideration with respect to workmanship provisions. Aesthetic issues such as color or architectural appearance, that are not part of a zoning code, should be addressed as part of the agreement between the owner and the contractor. 2. Renalling Wood Decks:When replacing roofing, the existing wood roof deck may have to be renaited in accordance with the current provisions of Chapter 16 (High Veloraly Hurricane Zones) of the Florida Building Code. (The roof deck is usual concealed prior to removing the existing roof system). _3. Common Roofs: Common roofs are those which have no visible delineation between neighboring units (Le. townhouses, condominiums, etc.). In buildings with common roofs, the roofing contractor and/or owner should notify the occupants of adjacent units of roofing work to be performed. _4. Exposed Ceilings: Exposed, open beam ceilings are where the underside of the roof decking can be viewed from below. The owner may wish to maintain the architectural appearance, therefore, roofing nail penetrations of the underside of the decking may not be acceptable. The Florida Building Code provides the option of maintaining this appearance. bid 5. Ponding Water: The current roof system and/or deck of the building may not drain well and may cause water to pond (accumulate) In low -lying areas of the roof. Ponding can be an indication of structural distress and may require the review of a professional structural engineer. Ponding may shorten the life expectancy and performance of the new roofing system. Ponding conditions may not be evident until the original rooting system is removed. Ponding conditions should be corrected. 6. Overflow scuppers (wall outlets): It is required that rainwater flow off so that the roof is not overloaded from a build up of water. Perimeter /edge wails or other roof extensions may block this discharge if overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in accordance with the Florida Building Code, Plumbing. 7. Ventilation: Most roof structures should have some ability to vent natural airflow through the interior of the structural assembly (the building itself). The existing amount of attic ventilation shall not be reduced. It may be beneficial to consider additional venting which can result in extending the service life of the roof. )1/114 Owner's/Agent's Si nature / /, Date Contractor's Signal Property Address Permit Number Rev:112012005 Complier Services, Bolding Deperbnen1 GEOTECHNICAL ENVIRONMENTAL HYDROGEOLOGY AS B ESTOS "0N1II 11111114= DYNATECH ENGINEERING CORP. TESTING LABORATORIES DRILLING SERVICES INSPECTION SERVICES ROOFING CONCENTRATED UPLIFT LOAD TESTING ON ROOF TILE TO COMPLY WITH METRO -DADE COUNTY PROTOCOL TAS -106 MIAMI, September 18, 2007 PERMIT No. CLIENT: Pat Daley: DALEY ROOFING, INC. 78 NE 106th Street Miami, F133138 PROPERTY ADDRESS: Roof @ 375 NE 99th Street Miami Shores, F133138. TILE TYPE/ATTACHMENT: Double roll roof tile polyfoam set Inspected By: PB Testing Equipment Humboldt Scale Model 11-4620 Test No. Test Location Field Uplift Pull Test Test Result 01-68 Field See Sketch Below > Than 35 LBS Passed 69-80 Corner See Sketch Below > Than .35 LBS Passed 81 -92 Perimeter See Sketch Below > Than 35 LBS Passed 93-103 Ridge caps See Sketch Below > Than 35 LBS Passed ROOF TILE UPLIFT IN ACCORDANCE WITH MIAMI-DADE COUNTY TAS -I06 ROOF SKETCH 69 82 70 93 44 40 95 3991 41 42 4 81 80� Sincerely yours, Wissam Naamani, P.E. DYNATECH ENGINEERING CORP. Florida Reg. No. 39584 Special Inspector No. 757 92 91 90 89 88 87 79 22 38 11 23 37 12 1 6 71 5 10 2 7 82 97 24 3 8 72 4 9 36 16 25 35 17 26 34 18 27 33 19 28 32 20 29 31 21 30 N 45 52 7: 98 13 51 54 46 53 84 c 14 9 50 47 130 15 49 48 55 56 81 57 58 75 66 59 77 131 62 60 67 61 86 1)2 63 68 64 65 78 750 West 84 Street, Hialeah, FL 33014 -3618 Phone (305) 828 -7499 o Fax (305) 828 -9598