RC-08-790Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Inspection Number: INSP - 131520 Permit Number: RC -5 -08 -790 Scheduled Inspection Date: January 14, 2010 Inspector: Bruhn, Norman Owner: ALLEGRA, FRAN Job Address: 1160 NE 98 Street Miami Shores, FL 33138- Project: <NONE> Contractor: GULF BUILDING CORP Permit Type: Residential Construction Inspection Type: Stem Wall Footer Work Classification: Addition Phone Number Parcel Number 1132050180390 Phone: (954)492 -9191 Building Department Comments Passed Failed Correction Needed Re- Inspection Fee No Additional Inspections can be scheduled until re- inspection fee is paid. Inspector Comments CREATED AS REINSPECTION FOR INSP- 83041. January 13, 2010 For Inspections please call: (305)762 -4949 Page 9 of 31 Aroillteoture • November 15, 2009 Building Department Miami Shores Village 10050 Northeast Second Avenue Miami Shores, FL 33138 Re: Folio No: ert 1 Deslyn • Certification of Soil Bearing Capacity 1160 Northeast 98th Street 11 3205 018 0390 d, did Con struotlon lAana,yment Having reviewed and approved the Soil Conditions at the site addressed above, I hereby state that the soil at this site is undisturbed rock and sand adequate of supporting the design loads of 2000 psf. These soil conditions are similar to those upon which the structure's design is based on. This is in compliance with the approved plans completed by this office and pertaining to this project. To avoid any misunderstanding, I hereby state that, to the best of my knowledge, belief and professional judgment, this report represents an accurate appraisal of the soil conditions based upon visual observation and careful evaluation of observed conditions to the extent reasonably possible. No soil report was performed. Please call if I can be of further assistance. Respectfully Submitted Bert J. Loire, AIA AR92824 8450 SW 201 Street, Miami, PL 33189 754.264.4773 r_larasbel lsouth.net CGC-057230 AK92824 121•Wallace Drive • Delray Beach, FL 33444 3 10 11 12 Project: Address: Client: T S7 G Nye FRNATto' SOIL DENSITY REPORT - NUCLEAR METHOD - ASTM D 2922 (561) 347-0070 • (561) 395-5805 (fax) Allegra/Rajo Residence Addition 1160 NE 98th Street, Miami, FL Gulf Building Corp. Permit No: RC -5 -08 -790 Field Tech: Sam Albaz Area Tested: Footings Soil Description: Greyish Brown Fine Sand with Limestone Rock Project ID: 09- 0654.1 Report ID: D -0002 Date: 11/17/2009 Test Mode: Direct Transmission Proctor/ LBR ID: P -001 Max Density (PCF): 118.5 Opt Moisture ( %): 10.8% Compaction Reqd: 95.0% Location Probe Depth (in) Elev Wet Density (PCF) Dry Density (PCF) Moist. ( %) Compaction oho Results 5' N of front door 12 BOF 124.0 113.9 8.9% 96.1% Pass 8' E of SE corner of house 12 BOF 125.9 114.6 9.9% 96.7% Pass 25' E of SE comer of house 12 BOF 123.1 113.7 8.3% 95.9% Pass Testing Gauge Information: Manufacturer: Humboldt Model: Remarks: Density Standard (DS): 5001 P S /N: 2395 Moisture Standard (MS): Legend for Elevation: PR = Proofroll SL = Springline SG = Subgrade BC = Basecourse TOP = Top of Pipe 1, 2, 3 = 1st, 2nd, 3rd Lift FL = Final Lift BG = Below Grade BOF = Bottom of Footing FG = Finished Grade Test report shall not be reproduced, except in full, without the written approval of GFA International Respectfully Submitted: GFA International In.y FBPE CA # 49 ! l .err/'' / _L.►+! ► ard, P.E. 2/15/2009 Professional Engineer # 64065 State of Florida Environmental • Geotechnical • Construction Materials Testing • Special and Threshold Inspections • Plan Review and Code Compliance Florida's Leading Engineering Source www.teamgfa.com 121$ Wallace Drive • Delray, Florida 33444 frij S7ING•/9 FRPIAf3® Laboratory Compaction Characteristics of Soil Using Modified Effort (Proctor) ASTM D 1557 (561 - 347 -0070 • (561)395 -3971 (fax) Project: Allegra / Rajo Residence Addition Address: 1160 NE 98th Street, Miami, FL Client: Gulf Building Corp. Soil Location: Sampled By: Sam Albaz Tested By: Antonio Viana Soil Description: Brown Test Method Used: Type of Rammer: Specific Gravity: Comments: Back Yard - Bottom of Footing; Sample ID: 2698 Project ID: 09- 0654.1 Report ID: P -001 Permit Number: RC -5-08 -790 Method C Mechanical Date Sampled: 11/16/2009 Date Tested: 11/17/2009 Preparation Method Used: Moist As- received Water Content: Specific Gravity Test Type: Greyish Brown Fine Sand with Limestone Rock Sieve Results Sieve Size (mm) Weight Retained Percent Retained 3/4" 19 7.6 18.5% 3/8" 9.5 2.9 7.0% #4 4.75 1.6 3.8% Pan 0 29.1 70.6% 120 119 118 v 117 0 DRY DENSITY 116 115 114 113 112 111 o- 7 8 9 10 11 12 13 14 MOISTURE % 15 Dry Density (pcf) Moisture ( %) 115.5 8.4 118.2 10.2 118.1 11.5 112.2 14.4 Maximum Dry Density (pcf) 118.5 Optimum Moisture ( %) 10.8 Respectfully Submitted. GFA INTERNATIONAL, INC. FBPE CA # 4930 F. St Professional Engineer # 64065 Test report shall not be reproduced, except in full, without the written approval of GFA International State of Florida Environmental • Geotechnicai • Construction Materials Testing • Special & Threshold Inspections • Plan Review & Code Compliance Florida's Leading Engineering Source www.teamgfa.com ArGhiteGtur& December 10, 2009 Building Department Miami Shores Village 10050 Northeast Second Avenue Miami Shores, FL 33138 Re: Folio No: Inspection Report 1160 Northeast 98th Street 11 3205 018 0390 d,dd • Gonstruotion Manciy t Having performed and approved the required Special Inspector inspections for the following structural building elements: Foundation Reinforcement Reinforced /Grouted Masonry Tie Beam, Concrete Beam Reinforcement I hereby attest that to the best of my knowledge, belief and professional judgment, the structural components of the building elements described above are in compliance with the approved plans, and other approved permit documents completed by this office and pertaining to this project. I also attest that to the best of my knowledge, belief and professional judgment, that the approved permit plans represent the as -built condition of the structural components of said building. This document represents an accurate appraisal of the building elements based upon careful evaluation of observed conditions to the extent reasonably possible. Please call if I can be of further assistance. Respectfully Submitted Robert J. Lara, AIA AR92824 8450 SW 201 Stret, M1am1, FL 33189 754.264.4773 r_larot bellsouth.net GGG057230 AK928z4 Arohit&c.tur& Addition to: 1160 Northeast 98th Street Folio No: 113205 018 0390 Finished floor +0' -0° tap of joist Robert J. Lars, AIA AR92824 November 15, 2009 r boot.. 1 • E;,613,,, • existing 01111 wall, and tie bear( to be ranoved aid properly disposed of cunt decorative 5 In ti wood Erse (not shown) 13edr new 3/4° finislhd No 1 oak 'ppinarks to match existing finish 1inistvd nailed to sub-Floor on approved liner w/ 4° lop on 3/4° p.t. plywood subfloar decking w/ 10d nails at 6° ac. to joist level transition a did construction Mancry&n1e t 1/2° drywall bedroom side 1/2° moisture resistant drywall bathroom side of 3 5/8° wide 24 gage metal stud partition w/ studs at 16° o.c. 2x4 p.t. sill Qathrm existing 2"xB° SYP wood 1 Dist at 24° o.c. on existing joist pt sill existing grade existing 12° wide stem call to remain w/ existing 4 core - - cap - and - existing 12 °x20° carc Footing 1/2° stone tile' on "34 grout leveling bed on I/4° thick 'Dens Shield tile backer bocrd glued and screwed to joist on 3/40 p.t. plywood sub Floor glued and nailed to foist w/ I0d nails at 6° o.c. p of joist new 25cB° SYP wood joist at le a.c. at bathroom set at lower elevation 1x8 p.t. sill plate USP RT24 twisted strop each new card existing joist w/ (6) 10d nails to joist and (6) 1/4° X 2 114° long tapcons into black typ Revised Section B per As -Built Conditions 8450 SW 201 Street, Miami, FL 33189 754.264.4773 r_Iara €bellsouth.net CGC057Z30 AK92824 Date: January 12, 2010 Village of Miami Shores Building Department 10050 N.E. 2nd Avenue Miami Shores, Florida 33138 Re: Lalanne Residence 190 N.E. 91st Street Miami Shores, Florida 33138 Attn: Building Department, FL LiC. t AR 008074 ®9/317 I, Mark A. Campbell Architect, represent the owners of the above referenced property. I have inspected the footing, columns and tie beams We would request that the inspection be approved. If any additional information is required please do not hesitate to contact my office 305 754 2318. Respectfully submitted, Mark A. Campbell, Architect State of Florida: #0011074 Lalanne Res Garage inspection 1et l -12 -10