Loading...
RF-08-2045Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Inspection Date: December 15, 2008 Inspector: Rodriguez, Jorge Owner: CHASE, JEFFREY Job Address: 145 98 Street NE Miami Shores, FL 33138- Project: <NONE> Block: Contractor: DENNIS ROOFING INC Permit Type: Roof Inspection Type: Final Roof Work Classification: Roof - New Phone Number Parcel Number 1132060132311 Lot: Building Department Comments Friday, December 12, 2008 Page 1 of 1 Passed Inspector Comments cc CY4 Mt Failed Correction Needed Re- Inspection Fee No Additional Inspections can be scheduled re- inspection fee is paid. until Friday, December 12, 2008 Page 1 of 1 Miami Shores Building Depart 10050 N.E.2nd Avenue, Miami Shores, .Fls'' da 331 Tel: (305) 795.2204 Fax: (305) 756.89t*----' BUILDING PERMIT APPLICATION FBC 2004 edi3lon ollofm 5''1/2 6u t' )ePhone # Se!? -1,6S Permit Type (circle): Building Owner's Name (Fee Simple Titleholder) Owner's Address / -/S /11E 47 City l n ion;i reS State *K. f Permit No. R,-'i- O2o ys Master Permit No. Tenant/Lessee Name A-44 Zip /9! Phone # Job Address (where the work is being done) City Miami Shores Village Iv k 5 4 County Miami -Dade Zip 33)_R8 FOLIO / PARCEL # Is Building Historically Designated YES NO jr Contractor's Company Name a a S Contractor's Address / 3 / 5 -- / q of City 1 ifq State C Qualifier Name ° r,n'I S State Certificate or Registration No. it Phone # so-44.5.5 Zip Architect/Engineer's Name (if applicable) Phone # 3h d 5S Certificate of Competency Ndee..0 0 .c7) ? Value of Work For this Permit Type of Work: DAdditiio Describe Work: Phone # Square / Linear Footage Of Work: r7 S , ❑New Repair/Replace ❑ Demolition Submittal Fee Notary $ Training/Education Fee $ Technology Fee $ Scanning $ Radon $ Bond $ Code Enforcement $ Double Fee $ Structural Review. $ Total Fee Now Due $ See Reverse side -> * * *****.x***** ***** ****a: **** ** Fees **** *** ***:x******** ** * ******* * *** * *** ****** ry2. Permit Fee $ `' CCF $ CO /CC DPBR $ Zoning $ Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) 66411 Mortgage Lender's Address lVC) City State NA Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. he ab + . such posted notice, the inspection will not !fie approved and a reinspection fee will be charged. Signature Owner or Agent Contractor The foreg a wledge - fore me this/ The forego 2 ' strument was acknowledged before me this" day of i • , , 2 by e 0.:51 ati,VAS ed who ' ersonally kno to me or who has produced as identittroafi n anci_urh idiri take an of t NOTARY PUBIS , {',� MICHELLE E. ORBAN �• Commission DD 733579 V. sJ Expires ► . «R ber9,2011 Wed, Rim Insane MOMS nstrument was ackn day of , 20�lr, by ist�e'�rsonally knowj.48 me or who has produced identification and who did take an oath. NOTARY PUBLI c 1;' ,, MICHELLE E D OR 7AN 9 ign: EA) Decanter 9,201 1 �` � _ • �t ,'. My Commission Expires: tianeoaMs Sign: Print: My Commission Expires: * * * * * * * * * * * * * * * *** ****** :***** * ** ** x**** :* ::****: x****: x*********** ******* *+r< *** * * *a: *** * ** *** * * * ** APPLICATION APPROVED BY: (Revised 07 /10/07) * * * * * * * * * ** Plans Examiner Engineer Zoning gip' v a 1-� o Ge Master Pmt No. Process No - - - - - -- corutrada's Nom / &I NS 6 C6 v s;l 0 ADO Floricht Building Code Edition 2892 HO Velocity l otter° Lone Unicorns Perna Appilaation Form. Job Address 1 cif S 1V 'oss -asp -w —j ROOF CATEGORY O Mechanically Fastened Tits 0 Mortar/ O Metal PaneVSluhugles 0 Wood 0 Prescriptive BUR -RAS 150 ROOF TYPE f 0 0 ( c 03 Are there Gas Vent Stacks? Yes c.1 No Type: Natural 0 LPGX 0 e-RooMg 0 Recovering 0 Repair 0 Maintenance ROOF SYSTEM INFORMATION Lou Slope Roof hrw ( Stew Sloped Roof Area (SF) Total (SF) CS'O CSO SimonB(R .PIs� Sketch Roof Plari illustrate all levels and sections, roof drains, scuppers, overflow ors and ~low drdna. Include d of sadism and leads, decty identify dimensions of elevated pressure zones and location of parapets ammil iii /MwrawrMi■■■ MBA/ rM■ iw/ sMMar/ saww//m mem/amM /w /r/MS■wswilmommimmemoM ^ - IrrM■Mwsrm■ /ommorr G fi mmg!mmm r- .TGllmo comet •mosiairrwwwswwwwi/s /m /wmmigim / /rows■ imminommwmpwammummilmA/limmllarrAmmummsammummilimmomzumitiminmomorigunsrmammis . Ir mai■ M/ rmosorsaummr w iiezommommursummummMYIi/i•Ridi7 moimum1 /rwVawnw madammi /aa■ m I/rrssam MNM� rra+� m rrr /r/!l 1 MKOMMIMMAMM / /it,llfWirAXs��L�: IROP2MMw /\i 4 SOMMUMMPi� NOMMK+!NW[ItlIIK'aP ■wRIENNI O.1 /fAJ1WMMl- /Marts /s:.i w /MUNOMSMMENKAIMMwsrV`M IMrs1Ea MMPIIMQ.Si�.al lmi gwMMOWMIa ells OV it lrl /rlrarMwwMr�MOMM /M /rws /rlIIIWIE w■ Srriaawrll•"M: glir ,%Jirt • ►rrCaaiMLLaM ►I ■rwMwMNI MS /Mr IC! M)t!!`JGAMMaWywiSKOng Iar■ ■Mwr-nslli maim,:,;, JMllasriijlasrminnu rsrr /a /rr / /UUMummkoMIIMwrt/aiu/1111 isi.M /MKil1C'll umrl•s']immu mimes /L;M im/■ si/ wrrrrrMissumm ummMMIimmivimomosm1Rrr/:Ir Ifs /Mats" •r5i ii;rummo P�'I 7•M■immun MSis ■aa■Mr1M/■rasiaMMMammAv gP!ma 7 assii<■Mir1Ma Im•M■uMNnsimire`nsr` it 1111,■ ■C ilY■ wali■r sommum mrmmwMM • #errmummmasMM /rr■Mrr...1 moms AMr• /arsfllsl�Ifr'MG1rrLM ritirMSwiilrrrll±( wits/ i■ aiirM■■■ MMiiiMMM •ssisfrwtltiMirV'ii�!a• ■MM IM ■MIM ■MTWAMOMMIIM Iw1MMM /MEMIMMMw►1'f A lilt/ 1fI��11 ►G.r"7r /MM /rwMMMMERAMallll.MI MM'APMANW IMMUMMOW,AUMMINANINIMMSWINMEMMUMERIMUMNICAMMAAMONEXWMEMMINNENUMOnANWIIMMOMPIWWWW ' is/srm.rrtau_..�..� .rrr••+ , ..____ __;MSMJmmmursi lirl.Srnimmmu•M■m■■Lais.ir /mrl6Mar■ 4nzaaa.■ai ilimmeawrMMamummummummilms ouunimmwmaimmsarwiw mmiri 7 iromimpmssir tormmemisr1hirraMaarrr /awrrrr m m arrr /ii'iLluummimm ararwMrr /Mirrwrrr isr?9Mmor iia@iif manssl'Srra■suss!isi■ Sts■■ uUMMaM■■ rrmnsimomMr r ■wa ■rw /m/MmMSYrirsmisnrw>,n I/ aMr Easwmalissmanommwrr isMairrMlirw. ■m ■ /s /s.MSSSSrra ■M /arts ■Mwl.Mwr1ssra.M ■mll Iswwfslrri■immos ■ell /m�'!immonrs `JSSir/sMMwmsruesr ensMriwaimmim Iyrrnmsnim r1■ 4^•" •""-'` iirr1.ilss//■ sswaMrrair •MMmMrrwri■ /wawiarommuur /ssm IrmssmmmunmvmUUM �M r si umn msnmwmw4/wwrrMMamwmmmmnxmmmmr•MM•a mmxrrwummmmmmmi ihirarmarnaluirraslc , llrissswirrir mlissaiarsMSrma /runes•airsManimmu MricasrSOC mil IMMwsamwmen tamrrmnimm wn rimm usMirmmu lltruersrasarrmummwaaxxzr /rarnrru imma rsra.Ml7ssirarimmi l�ir!lvMis/ luau/ aw/ rMrr/ aarrwriiw /rrrislwaMrwia / //swrMM1 isriMMIMrUMI M.MSrMMI WW 1 LIMMIB ssl' isMrM /aMMSrrMirsrMMiaMMMMrraMSAL&LL •sir :l7] IMSr ■wEMAIMIMMSSwralia.AMasMMrws/ ' 1rrMMaMMMMwssMMr /assmsMMLMMGMasai]aIM IsiIMmmgemMMlraisermummsrsrarMai" mummaw� V'as/airMrair /asisassirssimso sss /tom Ir'mnasaj•• slur / stems /wsrmsisraMSirrs.MMMaw•s■ rows /ssmimmu /ssi■NMSSMMasmsrarM IwaMMr misiM arMwiMwsriw■ _,_-__ -,_. a/►1r.:ri / ■■a /s ■mr ■MM ass ■•M•■ /lUMMiiif.l.I •■brat it IsMMrRSSr /sai�rit•wittriwMrrMUMEN VIVA IIMMESE MrMSrM /MMOMMMrrMENNEWI AMiIMMIOMMMraMi burssrwrss■ earrnimm raMrsissri.\/ sm rP.m rlstar auriul .rwssr•MMMaw /.Mrt( / /ss.JJii ISaMSSmMarsMMMSarMrrrMiMaMa /ssM ■MI MOial l• ■ aura / MMMMNIMSSMisMNtsMrllMS /Ma1IM /MM INMMM■MmrMMSrrMmMasiMMMSMisrss■ •UI ■ill:' -A■ MaMwsr /arMMMMMMrssMSMlssPWRIIM /MMAAAA IUMrsassrrrswarms /UMrwasrwsarr, M•I 1•iir•wa rrr• MrrrrsMSrM /roammarrilmMSrsimmens IsammammirsmsalSUminemS /MMrar,7 sir! ■Mro.Irsiwsswi mummuriswMrsssawMMMMMIIiiiMi IssassrasrrsrssssassrrasssssaRM iairw /srrisMMwrssrrmiasrMmsaimmomeas ism•ssMSmam mimmi ■■M ■MmrmssrararrarrMmomm rrsrarrism ummi■sri•rM mimmmamMi Iamrrmaammirare ■aarraraaaraaraammummi MSr uni russet ■rMM ammum a mmum /awo i■ ■ MMaaM■ aaMMIMarrmaMrrrsaMrMMMI■ Maars aM■ MrarMMMMrMMarrrrrraMrraaarr ssMM /rMM Ia Mas MMrraa/ s■■ w• M■■ MII MMOMarrraMMUMNU MUUs UUNOWOUVUUUMrrwaM ■rmauMMmMMU•UMMM■ I■ mm s■ aaMimminmamasrrrwaaraaawaasammum ummiasiaaar Mmummu ar/rasrass larsrmommi mmonraraMirssarrarrssrwrrrrsaar ■aa■ ■rrr /rrrrEMsrrrssaaamrrrMm m %M EMMINIONIMMMMMEC. MEEMEEMMEMMEEEMEEEMMMMONNESIMMEEMMMIMEMMMMEEMMNIMEMMEMINUMr IMMIraMMaa /SMOMMIRI MMaarrMSM■MMS ONMaMM•raaaMMMMMMSar OWEI MSSSaMS /rrMSMSaw■ IMSMMl■ Mra SSSS aaMa■ wa■ sM aMa■ IIMMI■ IISUMSMMuSSru •SaaraaMaaalMas..SMMisMu.11 M IaaaaarummisSMSSmsiis marmsmmarmisim saMlMasaMMM umumaSaimmammammaimmenMM 123_01.48 5/03 PAGE 2 ••• ••• • ••• • ••• • ••• ••• ••• • ••• • •• • • •• • •• • • • • •• • • •• • •• • 1 1 Florida Building Cale Edition 2002 High Velocity Hurricane Zone Uniform Peradt Applicatkin Foam. Section C (Low SloreJJ Roof System) Fill in Spedfic Roof and Wadi* Manufacturer Assembly Comments __ (Ifa component is not identify as NA") System ni E NOANo.: 07-/D1/43.3.q Design Wind Pry, From RAS 120 or Calculations: Pmax1 5›. Puma '? Pmax3: —12/ a Max Design Pry, From the Speditc NOA System: Deck Type: h`b' Gauge Mid mess: Slope: AnchorjBase Sheet & No. of Ply( 9 740064sioe Sheet F Materlat r j, °? gs.))►.9 �'i9t,, may. - Insulation Base Layer. A/A Base ikon Size and Tom: Base insulation Fastener/Bonding Material: Top Insulation Layer Top kin Size and Thl Top Insulation Fastener/Borg Fastener for AnchodBase Sheet Attadummt Rekk oc ( Lap,# ROWS , Perimeter: ! ° oc @ Lap, # Roast Corner /a oc Lap, # ROWS I/ Number of Fasteners Per insulation Board I d n L, Field meter Comer Illustrate Components Nom and Details as Applicable: Woodblocking, Gutter, Edge Termination, Strom, Flashing, Contlnuous Cleat, Cant Strip, Base Flashing, Counter- Flashing, Coping, Etc. Mean Roof Height, Parapet Height, . Height of Base Flashing, Component Material, Material Thickness, Fastener Type, Fastener Sparing or Sutunit Manufacturers Details that Comply with RAS 111 Chapter 16. Base Sheet(s) & No. of Ply(s): Base Sheet Fastener/Bonding Mater. Ply Sheet(s).& No. of Ply(ssa Ply Sheet N Top Ply: / +qF Pri9' ?o Mod); / -r, taio ri 4 ; / . 4 Top Ply Fastened . , Surfacing (' of •• •••• • m14 clog' • •• ,.p • • • • • , •• • •� ••••1• • Roof • • H h�••• Parapet Height ••• ••• • ••• 6-,061.„0 • Tel (r)e' Dt)vap,r5.00 • 1• • • • • • • • • • • 123_01 -48 5/03 PAGE 3 Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 BUILDING PERMIT APPLICATION FBC 2004 Permit Type (circle): Building Owner's Name (Fee Simple Titleholder) Owner's Address 5 9 75 City / fl State Zip Tenant/Lessee Name Ai Phone # Al Permit No. Sa (79777. Ai8 idl 2 �W 1 :add 2 BY: Master Permit No. vo4tk Phone # / A- R S 7i? Job Address (where the work is being done) /1/5 rit'a 92s4 City Miami Shores Village County Miami -Dade Zip FOLIO / PARCEL # Is Building Historically Designated YES NO Contractor's Company Name (a l 2C( Phone # 3 o5 ()S 3- 5 $ Contractor's Address )30g City \ rJ State C ` Zip tS 1j q Qualifier Name c-1 'S Phone # 3c.S— .5 .5.6110.1% 5-5 State Certificate or Registration No. �\ Certificate of Competency No. oo� 191B 1 Architect/Engineer's Name (if applicable) 1 J i Value of Work For this Permit $ U saw y Square / Linear Footage Of Work: '7St4 SL 4r Phone # Type of Work: ['Addition ■ Alteration ['New dzt. Repair/Replace ❑ Demolition Describe Work:•:J . 11117 I **** *** *** **** **** *** * **** ***** **** Fees************* ** **** ** ** * ** ****** ** * *** * ** *** Submittal Permit Fee $ CCF $ 4' Notary $ Training/Education Fee $ ' Ai Technology Fee $ . �� �_ Scanning $ " l Bond $ Code Enforcement $ Double Fee $ Structural Review. $ Total Fee Now Due $ G O.15 Radon $ DPBR $ Zoning $ nr See Reverse side -* 107 117402 2402 47 m }rri 1 -1695 DIE Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will e delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. I the ab f such posted notice, the inspection will not be approved and a reinspection fee will be charged. The foregoing in trument was acknowledged before me this day of ° 2(O', by 411-0 511(1GGvavohaa, who iser; known +o me or who has produced As identification and who did take an oath. NOTARY PUBLIC: Sign: Print: My Commission Expires: ********************* Signat rW /Aviv Contractor The foregoing instrument was acknowledged before me thisf day of , 200 Fc, by /41: £5 t DC, L3:) 1,5, who is personally known to me or who has produced as identification and who did take an oath. NOTARY PUBLIC: My Commission Ex ** * * * * * * * * * ********* ** * * *** APPLICATION APPROVED BY: (Revised 07 /10/07) Plans Examiner Engineer Zoning 11/26/2008 13:41 3052586410 DENNIS ROOFING NOTICE OF COMMENCEMENT A RECORDED COPY MUST BE POSTED ON THE JOB SITE AT TIME OF FIRST INSPECTION PERMIT NO K-06 °S• TAX FOLIO NO STATE OF FLORIDA: COUNTY OF MIAMI -DADE: THE UNDERSIGNED hereby gives notice that improvements will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following Information Is provided in this Notice of Commencement. 1. Legal description of property and street/address: 2. Description of improvement: 3. Owner(s) name and address: rim Interest in property: 1(}0% his ear 5 PAGE 05 1 11111111111 11111 11111111111 1111 11111 1111 1111 GFWI 200Si 'c 95009'S OR ek 26661 Ps 33481 (1Rs) RECORDED 11/24/2008 10:13 :49 HARVEY RIJVIN, CLERK OF COURT MIAMI -DADE COUNTY, 'FLORIDA LAST PAGE 33/3. v adq /07/ M •r.,rr.-7r •Ps Name and address of fee simple titleholder: n/a n/a 4. Contractor's name and address: Dennis Roofing /no. P. O. Box 924273, ;k'' .11c +an, Fla 33I 471: �;�: ,.i r,� ;.t;: „ t < uN-Y c:F 5. Surety; (Payment bond r uIrdd b owner from contract �x;r `j ::' "� t�� "'`'y "�`�,`' tY� iF' Ym BQ by or, ��a►ay) � : , ., t'.. •.., ., , _ :.C/ y`� .. Name and address: n./ a •. „A DA r.= Pte Amount of bond $ ,, °l .:�'Y; W n/a i ,a •'t. :4.` t:', _ ti:: t nb ar li +� �. r1.;;:,.•'. .1 6. Lender's name and address* n/a c,. / � 8 C 7. Persons within the state of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)7., Florida Statutes. Name and address: n/a n/a 8. In addition to himself, Owners designates the following person(s) to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b), Florida Statutes. Name and address: r1 /a n/a 9. Expiration date of this Notice of Commencement: (the expiration date Is 1 year from the date of recording unless a different _te is specified) I�JAr /vf Prepared by Michelle E. Orban Sworn to and subscribed before me this 3 f day ofc j , 20 ©q Notary Public Print Notary's Na My commission expires: • 123.O1 -82 PAGE Sh12 Address: 13061 S .W. 122 Ave. Nliaz.i,,r Ella. 33186 OWNER'S AFFIDAVIT OF EXEMPTION ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR EXISTING STTE- BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES PURSUANT TO SECTION 553.844 F.S. [ Date ] To: Miami-Dade County Building Department 11805 Coral Way, Suite 111 Miami, FL 33175 Re: Owner's Name Property Address 1gS Roofing Permit Number Dear Building Official: I [ Property Owner ] certify that 1 am not required to retrofit the roof to wall connections of my building because: EfThe just valuation for the structure for purposes of ad valorem taxation in less than $300;000.00. IDThe building was constructed in compliance with the provisions of the Florida Building Code (FBC) or with the provisions of the 1994 edition of the South Florida Building Code (1994 SFBC). A'1.79 7---Sigiiature_ofPro er 00 -C. Nut Name t") 0 STATE OF FLORIDA COUNTY OF MUM-DADE Sworn to day of (SEAL) MICHELLE E. ORBAN f4 Commission DD 733579 Expires December 9, 2011 Bonded Thu TroyRin Wont* 800-385.7010 When the just valuation of the structure for purposes of ad valorem taxation is equal to or more than $300,000.00, and the building was not constructed in compliance with the FBC nor with 1994 SFBC, and affidavit ofRoof to Wall Connection Hurricane Mitigation Retrofit must be provided. {', 77P fie;V 2 4 2108 i., • SECTION 1524 BY: HIGH VELOCITY HURRICANE ZONES REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS 1524.1 As it pertains required roo • •_e the por syst -n instal all own - land }f to this section, it is the responsibility of the roofing contractor to provide the owner with the d to explain to the owner the content of this section.. The provisions of Chapter 15 of e, Building govern the minimum requirements and standards of the industry for roofing ronany, the following items should be addressed as part of the agreement between the The owner's initial in the adjacent box indicates that the item has been explained. anship: The workmanship provisions of Chapter 15 (High Velocity Hurricane Zone) f /lov�iding that the roofing system meets the wind resistance and water intrusion 1 esthetics (appearance) issues are not a consideration with respect to workmanship 4 es such as color or architectural appearance, that are not part of a zoning code, should of the agreement between the owner and the contractor. 2. Renaiiing Wood Decks: When replacing roofing, the existing wood roof deck may have to be renailed K in accordance with the current provisions of Chapter 16 (High Velocity Hurricane Zones) of the Florida Building Code. (The roof deck is usually concealed prior to removing the existing roof system). ft/ 3. Common Roofs: Common roofs are those which have no visible delineation between neighboring uriits (i.e. townhouses, condominiums, etc.). In buildings with common roofs, the roofing contractor and/or owner should notify the occupants of adjacent units of roofing work to be performed. '�� II 4. Exposed Ceilings: Exposed, open beam ceilings are where the underside of the roof decking can be - - viewed from below. The owner may wish to maintain the architectural appearance, therefore, roofing nail penetrations of the underside of the decking may not be acceptable. The Florida Building Code provides the option of maintaining this appearance. 5. Ponding Water: The current roof system and/or deck of the building may not drain well and may cause water to pond (accumulate) in low -tying areas of the roof. Ponding can be an indication of structural distress and may require the review of a professional structural engineer. Ponding may shorten the life expectancy and performance of the new roofing system. Ponding conditions may not be evident until the original roofing system is removed. Ponding conditions should be corrected. 6. Overflow scuppers (wall outlets): It is required that rainwater flow off so that the roof is not overloaded from a build up of water. Perimeter /edge walls or other roof extensions may block this discharge if overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in accordance with the Florida Building Code, Plumbing. 7. Ventilation: Most roof structures should have some ability to vent = "ral ai ow rough the interior of the structural assembly (the building itself). The existing amount of attic ve +on sl =11 not • - reduced. It may be beneficial to consider additional venting which can result in extending the of. id/AZ/47 er s /Agents Si l4 /5 'V Property Address /l af Contract° s gnature Permit Number _ nPut Serer BWIdlirg DepaRMe f PERMIT : ;'f II r` SUBJECT TO COMPIJANCE WITH ALL FEDERAL STATE AND COUNTY RULES AND REGULATIONS h-----"611.77771;9;71--. a A� f 1 Florida Building Code Edition 2002 2 t-J �� h Velodly Hardpuro Zone Uniform Permit Application Form BY: 11 S to A en 1 1 �f � Prows No. O1Sr PO I-S Z Master Penult No. Contractor's Name I Job Address 1 Lis W + s ' )are) ROOF CATEGORY Low Slope ❑ Mechanically Fastened Tile ❑ 0 Asphaltic ❑ Metal Panel/Shingles ❑ Shingles ❑ New Roof ❑ Prescriptive BUR -RAS 150 „Re- Roofing ROOF TYPE Mortar /Adhesive Set Tile Wood Shingles/Shakes Are there Gas Vent Stacks,' Yes❑ No Ma Type: Natural ❑ LPGX ❑ ❑ Recovering 0 Repair ❑ Maintenance ROOF SYSTEM INFORMATION Low Slope Roof Arv, (5_10 (S Steep.Sloped -Roof Area (SF) Total (SF) SK C5.0 Section R (Roof: Plan) Sketch Roof Pim Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zone and location of parapets. Isonno i■SRr1 mmemmumu E11immu<•mimmu = um litsommu tmum1m11ummui mmstams[•n IasNNS insmani n iurtml m iommammom iNNSisaNNNiSaNNSSSaNisaNSNNonom Nassumume i1NNSNNNNNNIMMI , P WR AsMMIMOMMSSNNNasNNNNaaNNNiNOWNSI !' WAWISIi s►�l►ls`s�rsaiisaia INNNNNSSSNNSNNS_N _r► r_NNSN__rs'SSNNNN NNNNNNNSNNNSaIrIMMKAt"iIN /111 tNiii►isSSNSiN■ INsNNNNSS�/NWRWIN11�" r!'� -- ImINNNNNNSNisaisaNSNis2I NAMAXiiitA WWWW /N1NSiN■ INNNNNNNS,irmmmuNg umminiMoN. NN i1t 'N1aNNNNNNNNNNNINNNNimmmunimm NNrINNNI►iiNNNiits INNNNiauaan lNaisiNN/: 1S1s■ NlSaNissNNNNNNSSNNNNNNaNUUUUU NN•NSNUNNNNSSNals.N�_■emar iN Ss sssi'rt, lss N'ir.!4 l4 i��emm ilN ■ ■NNANUNNNNNNNi•NNNNNNNNNNN! wtao UNI<mmorsl! N■ I ale ..' . 171 .mumwzrI,�"di..�!�miiUSivai.Nsm NN.NSN ssi.NNia.NNu.N1\s.t"il.NS?Nmerm U#■ INNNNsNS11a�a1.uu.NrAiiimm UNNN.NNSaNaNNNsaNNNaNNas NNNNNSNSit /is►ado �=NNa�:rN'Nmo!I■ IaNSNNNm-NNI INNNSS a ,1�Niuua•NNMM NNNNNUNNNNNNNSSNNNNUUNSi AL UP1: e. NNi'.1NC�'nim INNSNNNuua1INNNNayei . II. mmmmnSSMSSSNNNN leas• UNNSNNNNUUN •NNNSNNUNNM'aaSumuu•Sai ISNSN ■SN11NNI INNNNNS'UMUNIMMaUSINUNUNUN UNNNNNNSUUNNasi■■NNNSNiria.SM U.?�JNis■ IsiNSNNN'iuNI lsmUSN iN SSSNNNaUNSS Si NNasUsiuuUS ■SNSiuSmmmSNNNNNSIINSIli vs►su'auuNN• INi ...... N! iNN NA- sNNNNNNNisiNNiiNiMNNNNNNNNNNNNNNNNNNNIU NNNNN E:N::NNNNNNNNNM Isle i•NNN ■1+► INSSUNN iNNIiUNU>E NNNUUTA %UNNNSSI' ummisUNNSNUNN ass NNNUUNNNN.NNNNNN SNUNN.sa INNNNNSNNSNIuNSNuUNaasuNUNS SNNI' INNSNN ■NNIIUNSaUummumUUUUNuuNmmmNNaum mis 1 N.UNNNNNNaSUNSUUN Nsii NNSNNS11SIUNNNNUUNSUNSUNNNNNUUNSNNNSNNNUUNSUNNS s Ni INNUUNis asslN' NNS.NNNIN m r m NNNN tiNNNSNNNNN11asNNNilvms oa p am manNNNUiNiiNNNN NNsNiNNNNNNNMs INSSiNNNNSSI !-^"' - - ... ISaaN N■ NN1NMNNNNrNNNN Ni1NM INSaN sssisla NI►Sui L Ni UNNSUINNSSUSUN NSNNUUSNNNNNNINNNNUUmmmnimisa orminiUNNNSaNNNilMMs maces mmassanumum 111111 SNSisN NasiNNSisaNNs ::NNNNNNNNNNNNNN►Nw INN NNN:N NNN NNNNNNNNUNNNNNNN N: NNNC . NNNNNN NNNN N NNNNN ISNNNNNNINN :NNeISimm%Amsss[ssiSNN NNSSNaNN.NaNSNSsmamor NNNSa u■N NN: NNNNN:N:NNN NNNNNNNNNNNNNNNNNNNNmsminmumN N fISNN.:a.NU NNN NNU Nsasi iU N N le UINSNNNN NNNanioni mow 'd.. NNNNNNNNNNNNNNNNNNNNNns NSasNSU : ..s.: ...NSNUNMN � NNNN NNUsm I NN: NNNNNNNUNNNUNNNNN INNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN NNN iNUIN1. NNNNN NN I NNNUUNN NSUNnsmarmanamSNi 1►wISINNNSSSSSSNNUNNNSa N SRNNUUNNU I s.NUUN ...Sll.N.SiN ouram mminm INN SNSSUNNNSss is NNNNN mommas• INNNNasaNSNa NNSaN•N1isisumnipNNNNNSNNanimmi NNNNNMNSSNNU s Na Si NNNN .UNaUS NNN sass i Uiwis■ NUNNSNis NNNUNNNs N sas NNUNN SNNSNNSNNSNNNUN NNNNNNSNNN NNis1NSNNNNNNSSUUNNNSUem I NNNNNS UUNSIUNNN$ UNNN SN N■ NNUNSN .UNNNNSSSNNNNSSN.i.NNU■ IUNUNNi SSSNSNNNSSN SN■ UUNiUUUNN NNSNSss Na1SNSNSsi NNNSSNN UIE U U .INNNNNNNNNNNNNN N: '•N: N N NNN NNNN: NNNNNNNNNNNNNNUNNNNNN N:NN"NN 1NNNNNNNaNN s a aNNNNNNNNNaNSsNNNisNNNSaiNNNNNaN NNNNSNNsa■ I N :N NmIU :U :: • :: U C moo N N: mUM'N :O mmi M UMMM C : 123_01 -48 5/03 PAGE 2 Florida Building Code Edition 2002 High Velocity Hurricane Zone Uniform Permit Application Form. INSTRUCTION PAGE COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING PERMIT APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED BELOW: Roof System Low Slope Application Prescriptive BUR -RAS 150 Required Sections of the Permit A . Iication Form A,B,C Attachments Required See List Below 1,2,3,4,5,6,7 A,B,C 4,5,6,7 Asphaltic Shingles A,B,D Concrete or Clay Tile A,B,D,E 1,2,4,5,6,7 1.2.3.4.5,6,7 Metal Roofs A,B,D 1,2,3,4,5,6,7 Wood Shingles and Shakes A,B,D 1,2,4,5,6,7 Other As Applicable 1,2,3,4,5,6,7 ATTACHMENTS REQUIRED: 1. Fire Directory Listing Page 2. From Notice of Acceptance: Front Page Specific System Description Specific System Limitations General Limitations Applicable Detail Drawings 3. Design Calculations per Chapter 16, or if Applicable, RAS 127 or RAS 128 4. Other Component Notice of Acceptances 5. Municipal Permit Application 6. Owners Notification for Roofin Considerations Re- Roofk' • On 7. Any Requ red Roof Testing /Calculation Documentation 123_01 -48 5/03 PAGE 1 t Florida Building Code Edition 2002 High Velocity Hurricane Zone Uniform Permit Application Form. Section C (Low Sloped Roof Svstem) Fill In Specific Roof Assembly Components and Identify Manufacturer (If a component is not , identify as "NA") System Manufacturer. OA E. NOA No.: 07° /Do -3.0/ Design Wind Pressures, From RAS 128 or Calculations: Pmax1: Pmax2: VJ Pmax3: >? %® Max Design Pressure, From the Specific NOA System: , - ._S Deck Type:.11/0 • Gauge/Thickness: Slope: % d T cY-5 Anchor/Base Sheet & No. of Ply(! 9 7 (�5,_4se Anchorqwe Sheet FastenedBorlding Material: Insulation Base Layer. /vA Base Insulation Size and Thickness: mess: Fastener Spacing for AnchorlBase Sheet Attachment Reid: 6 oc Q Lap, # Rows _20)(0 " oc Perimeter. " oc © Lap, # Rows_ © " oc Comer. 7" oc Lap, # Rows (� � " oc Number of Fasteners Per Insulation Board Field / " Perimeter Comer Illustrate Components Noted and Details as Applicable: Wood blocking, Gutter, Edge Termination, Stripping, Flashing, Continuous Cleat, Cant Strip, Base Flashing, Counter- Flashing, Coping, Etc. Indic: Mean Roof Height, Parapet Height, Height of Base Flashing, Component Material, Material Thickness, Fastener Type, Fastener Spacing or Submit Manufacturers Details that Comply with RAS 111 d Chapter 16. Base Insulation Fastener/Bonding Material: Top Insulation Layer: Top Insulation Size and Thidmess: Top Insulation Fastener/Bonding Materia Base Sheet(s) & No. of Ply(s): Base Sheet Fastener/Bonding Material. Ply Sheet(s).& No. of Piy(s Ply Sheet Faster/Bonding ylgteri�l;, 1 Top Ply: / 04,F Arid 170 Top Ply Fastener/ Bopdiing Mat Surfadng: (tin l/ /c7 S cloop°' Parapet Height Mean Roof Height 123_01-48 5/03 PAGE 3 MIAMId3ADE BUILDING CODE COMPLIANCE OFFICE (BCCO) PRODUCT CONTROL DIVISION MIAMI -DADE COUNTY, FLORIDA METRO -DADE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 MIAMI, FLORIDA 33130 -1563 (305) 375 -2901 FAX (305) 375 -2908 NOTICE OF ACCEPTANCE (NOA) GAF Material Corporation 1361 Alps Road Wayne, NJ 07470 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by the BCCO and accepted by the Building Code and Product Review Committee to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Division that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code and the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: GAF RUBEROID* Modified Bitumen Roof System for Wood Decks. LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA No. 03- 0501.02 and consists of pages 1 through 30. The submitted documentation was reviewed by Jorge L. Acebo. NOA No.: 07- 1203.01 Expiration Date: 11/06/13 Approval Date: 03/06/08 Page 1 of 30 ROOFING SYSTEM APPROVAL Category: Sub - Category: Deck Type: Maximum Design Pressure Fire Classification: Roofing SBS /APP, Modified Bitumen Wood -75 psf See General Limitation #1 TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Product Leak Buster" MatrixTM 307 Premium Asphalt Primer GAF Mineral Shield® Granules Leak BusterTM Matrix" 305 Fibered Asphalt Emulsion Leak BusterTM MatrixTM 303 Premium Fibered Aluminum Roof Coating LeakBusterTM MatrixTM 322 Elastomeric Roof Coating LeakBusterTM MatrixTM 306 LeakBusterTM MatrixTM 204 Wet/Dry Roof Cement GAFGLAS® #75 Base Sheet GAFGLAS® # ULTIMA" Base Sheet GAFGLAS® Flex PIyTM 6 GAFGLAS® Ply 4 GAFGLAS® Mineral Surfaced Cap Sheet Dimensions 5, 55 gallons 601b. Bags 1001b. bags 5 gallons 1, 5 gallons 55 gallons 55 gallons 1, 5 gallons 39.37" (1 meter) Wide 39.37" (1 meter) Wide 39.37" (1 meter) Wide 39.37" (1 meter) Wide 39.37" (1 meter) Wide Test Specification ASTM D 41 Product Description Asphalt concrete primer used to promote adhesion of asphalt in built -up roofing. ASTM D 1863 Granules for surfacing of exposed asphalt, cold process cement or emulsion. GAF Mineral Shieldo Granules shall be used for flashing applications only. ASTM 1227 Surface coating for smooth surfaced roofs. ASTM D 2824 Fibered aluminum coating. ASTM D 3019 ASTM D 3409 ASTM D-4586 ASTM D -3409 ASTM D 4601 ASTM D4601 ASTM D 2178 ASTM D 2178 ASTM D 3909 Elastomeric roof coating. Asphalt emulsion fibered. Refined asphalt blended with a mineral • stabilizer and fibers. Permits adhesion to wet and dry surfaces. Type II Asphalt impregnated and coated glass mat base sheet. Type II Asphalt impregnated and coated, fiberglass base sheet Type VI asphalt impregnated glass felt with asphalt coating. Type IV asphalt impregnated glass felt with asphalt coating. Asphalt coated, glass fiber mat cap sheet surfaced with mineral granules. NOA No.: 07- 1203.01 Expiration Date: 11/06/13 Approval Date: 03/06/08 Page 2 of 30 Product GAFGLAS ®EnergyCapTM Mineral Surfaced Cap Sheet GAFGLAS® STRATAVENT® EliminatorTM Perforated GAFGLAS® Flashing GAFGLAS® STRATAVENT® EliminatorTM Perforated Nailable RUBEROID® SBS Heat- We1dTM Smooth RUBEROID® SBS Heat- We1dTM Granule RUBEROID® SBS Heat- WeIdTM 170 FR RUBEROID® SBS Heat- We1dTM PLUS RUBEROID® SBS Heat- We1dT"' PLUS FR RUBEROID® Modified Base Sheet RUBEROID® SBS Heat- We1dTM 25 RUBEROID® Mop Granule RUBEROID® MOP Smooth RUBEROID® MOP PLUS Dimensions 39.37" (1 meter) Wide Test Specification ASTM D 3909 39.37" (1 meter) ASTM D3672 Wide ASTM D 4897 various 39.37" (1 meter) Wide 1 meter (39.37 ") wide 1 meter (39.37 ") wide 1 meter (39.37 ") wide 1 meter (39.37 ") wide 1 meter (39.37 ") wide 39.37" (1 meter) Wide 1 meter (39.37 ") wide 39.37" (1 meter) Wide 1 sq. roll 87 lbs. 39.37" (1 meter) Wide ASTM D3672 ASTM D 4897 ASTM D -6164 ASTM D -6164 ASTM D -6164 ASTM D -6164 ASTM D -6164 ASTM D4601, Type II, UL Type G2 BUR ASTM D -6164 ASTM D 6222 ASTM D 5147 ASTM D 6298 ASTM D 5147 ASTM D 6164 ASTM D 5147 Product Description Asphalt coated, glass fiber mat cap sheet surfaced with mineral granules with factory applied layer of TOPCOAT® EnergyCoteTM. Fiberglass base sheet coated on both sides with asphalt. Surfaced on the bottom side with mineral granules embedded in asphaltic coating with factory perforations. Asphalt coated glass fiber mat flashing sheet available in three sizes. Fiberglass base sheet coated on both sides with asphalt. Surfaced on the bottom side with mineral granules embedded in asphaltic coating. Non -Woven Polyester mat coated with polymer- modified asphalt and smooth surfaced. Non -Woven Polyester mat coated with polymer modified asphalt and surfaced with mineral granules. Non -Woven Polyester mat coated with fire retardant polymer modified asphalt and surfaced with mineral granules. Non -Woven Polyester mat coated with polymer modified asphalt and surfaced with mineral granules. Non -Woven Polyester mat coated with fire retardant polymer modified asphalt and surfaced with mineral granules. Premium glass fiber reinforced SBS - modified base sheet Non -Woven Polyester mat coated with polymer- modified asphalt and smooth surfaced. Non -woven polyester mat coated with polymer modified asphalt and surfaced with mineral granules. Non -woven polyester mat coated with polymer- modified asphalt and smooth surfaced. Non -woven polyester mat coated with polymer modified asphalt and surfaced with mineral granules. NOA No.: 07- 1203.01 Expiration Date: 11/06/13 Approval Date: 03/06/08 Page 3 of 30 Product RUBERO D MOP 170FR RUBEROID® MOP FR RUBEROID® TORCH Smooth RUBEROID® TORCH Granule RUBEROID® TORCH PLUS RUBEROID® TORCH FR RUBEROID® 170FR TORCH RUBEROID® 20 RUBEROID® 30 RUBEROID®30 FR RUBEROID® ULTRACLAD® SBS RUBEROID® Dual FR Vent Stacks (metal and plastic) Leak BusterTM MatrixTM 302 Non Fibered Aluminum Roof Coating GAF Built -Up Roofing Asphalt Dimensions 39.37" (1 meter) Wide 39.37" (I meter) Wide • 39.37" (1 meter) Wide 39.37" (1 meter) Wide 39.37" (1 meter) Wide 39.37" (1 meter) Wide 39.37" (1 meter) Wide 39.37" (1 meter) Wide 39.37" (1 meter) Wide 39.37" (1 meter) Wide 39.37" (1 meter) Wide 39.37" (1 meter) Wide 5 gallons 100 lb. cartons, bulk Test Specification ASTM D 6164 ASTM D 5147 ASTM D 6164 ASTM D 5147 ASTM D 6222 ASTM D 5147 ASTM D 6222 ASTM D 5147 ASTM D 6222 ASTM D 5147 ASTM D 6222 ASTM D 5147 ASTM D 6222 ASTM D 5147 ASTM D 6163 ASTM D 5147 ASTM D 6163 ASTM D 5147 ASTM D 6298 ASTM D 5147 ASTM D 6163 ASTM D 5147 ASTM D 6164 ASTM D 5147 TAS 100(A) ASTM D 1929 ASTM D 635 ASTM D2824, Type I ASTM D312, Types 1,11, 111 and IV Product Description Non -Woven polyester mat coated with fire retardant polymer modified asphalt and surfaced with mineral granules. Non -Woven polyester mat coated with fire retardant polymer modified asphalt and surfaced with mineral granules. Heavy duty, polyester reinforced, asphalt modified bitumen membrane, smooth surface. Heavy duty, polyester reinforced, asphalt modified bitumen membrane, granule surface. Heavy duty, polyester reinforced, asphalt modified bitumen membrane, granule surface Heavy duty, polyester reinforced, coated with fire retardant asphalt modified bitumen membrane, granule surface. Heavy duty, polyester reinforced, coated with fire retardant asphalt modified bitumen membrane, granule surface. SBS modified asphalt base sheet reinforce with a glass fiber mat. Non woven fiberglass mat coated with polymer modified asphalt and surfaced with mineral granules. Non woven fiberglass mat coated with fire retardant, polymer modified asphalt and surfaced with mineral granules. Woven fiberglass mat coated with Polymer modified asphalt surfaced with aluminum, copper or stainless steel foil. Non -woven polyester and fiberglass mat coated with file retardant, polymer - modified asphalt and surfaced with mineral granules. One -way valve vent used to relieve built - up pressure within the roof system. GAF Vent Stacks are available in metal or plastic. Non - fibered. Aluminum pigmented, asphalt roof coating Interply mopping and surfacing asphalt NOA No.: 07- 1203.01 Expiration Date: 11/06/13 Approval Date: 03/06/08 Page 4 of 30 Product RUBEROID® MOD Asphalt Asphalt L & Asphalt P TOPCOAT® Surface Seal SB (Matrix 602 SB Coating) LEAK BUSTER"' Matrix"' 715 MB Coating Label EnergyCoteTM Coating Leak BusterTM MatrixTM 715 MB Coating Label VersaShield® VersaShield® FB -IS VersaShield® FB -2S TOPCOAT® FireShield® MB Leak Buster.' Matrix"' 103 WeatherCoteTM Elastomeric Flashing Grade LeakBusterTM MatrixTM 201 Premium SBS Flashing Leak BusterTM Matrix"' 102 SBS Adhesive Label Leak BusterTM Matrix"' 202 SBS Flashing Cement Label Leak BusterTM Matrix"' 203 Plastic Roof Cement Label Leak Buster"' Matrix"' 103 Cold Process Adhesive Label LeakBusterTM MatrixTM 303 Premium Fibered Aluminum Dimensions 601b. kegs 5 gallons 5 gallons 2, 5 gallons 5 gallons 350 sq. ft roll 350 sq. ft roll 350 sq. ft roll 5, 55 gallons 5 gallons 5 gallons 5 gallons 5 gallons 5 gallons 5 gallons 5 gallons Test Specification ASTM D -2196 ASTM D -1475 ASTM E -1644 ASTM C -1549 ASTM E-408 ASTM -D 226 4869 Type I, II ASTM -D 226 4869 Type 1, II ASTM -D 226 4869 Type I, II ASTM D-412 ASTM D -21 -96 ASTM D1475 ASTM E -1644 ASTM D3019 AST' D3019 ASTM D4586 ASTM D4586 Product Description SEBS modified asphalt Surface coating for smooth surfaced and mineral surfaced roofs. Surface coating for smooth surfaced and mineral surfaced roofs. Highly reflective elastomeric coating Surface coating for smooth surfaced and mineral surfaced roofs. Non - Asphaltic Fiberglass -Based Underlayment Non Asphaltic Fiberglass -Based Underlayment Non - Asphaltic Fiberglass -Based Underlayment Elastomeric roofing membrane Surface coating for smooth surfaced and mineral surfaced roofs. Cold Applied Modified SEBS Asphalt Adhesive — Flashing Grade. Cold Applied Modified SEBS Asphalt Adhesive. Cold Applied Modified SEBS Asphalt Adhesive — Flashing Grade. Standard Plastic Asphalt Roofing Cement ASTM D3019 Cold Applied Asphalt Adhesive. ASTM D 2824 Fibered aluminum coating. NOA No.: 07- 1203.01 Expiration Date: 11/06/13 Approval Date: 03/06/08 Page 5 of 30 Product Dimensions LeakBusterTM MatrixTM 304 5 gallons Non - Fibered Aluminum Roof APPROVED INSULATIONS: Product Name EnergyGuardTM Fiberboard EnergyGuardTM Permalite EnergyGuardTM Strip EnergyGuardTM Recover Board EnergyGuardTM Tapered Edge Strip EnergyGuardTM Polylso EnergyGuardTM RA, RN EnergyGuardTM Composite, RA EnergyGuardTM High Density Fiberboard EPS Wood Fiber High Density Wood Fiberboard Perlite/Urethane Composite Perlite Insulation DensDeck® DensDeck Prime® DensDeck DuraGuardTM Structodek SecurockTM Test Specification ASTM D2824, Type I Product Descriptiro on Non - fibered. Aluminum pigmented, asphalt roof coating. Table 2 Product Description Fiberboard insulation Perlite insulation board Cut perlite board Perlite recover board Tapered perlite board Polyisocyanurate foam insulation Polyisocyanurate foam insulation Polyisocyanurate /wood fiberboard or perlite composite High density wood fiberboard insulation. Extruded polystyrene insulation Wood fiber insulation board Wood fiber insulation board Perlite / urethane composite board insulation Perlite insulation board Water resistant gypsum board Water resistant gypsum board Water resistant gypsum board Wood fiber insulation board Fiber reinforced roof board Manufacturer (With Current NOA) GAF Materials Corp. GAF Materials Corp. GAF Materials Corp. GAF Materials Corp. GAF Materials Corp. GAF Materials Corp. GAF Materials Corp. GAF Materials Corp. GAF Materials Corp. Generic Generic Generic Generic Generic G -P Gypsum Corp. G -P Gypsum Corp. G -P Gypsum Corp Knight Celotex USG Corporation NOA No.: 07- 1203.01 Expiration Date: 11/06/13 Approval Date: 03/06/08 Page 6 of 30 APPROVED FASTENERS: Fastener Number 1. Product Name Drill -TecTM #12 Standard, #14 and #15 extra Heavy Duty Fastener, Heavy Duty Roofing Fastener 2. Drill -TecTM ASAP 3. Drill -TecTM CR Base Sheet Fastener and Plate 4. Drill -TecTM Galvalume Plates 5. Drill -TecTM Polypropylene Plates 6. Drill -TecTM AccuTrac Plate EVIDENCE SUBMITTED: Test Agency Factory Mutual Research Corp. Underwriters Laboratories Trinity Engineering PRI Asphalt Technologies, Inc. IRT -ARCON Inc. TABLE 3 Product Description Insulation fastener and Base Play fastener for steel, wood & concrete decks. Pre - assembled Drill -TecTM Fasteners and metal and plastic plates. Base sheet fastening assembly. Round Galvalume stress plates. Round polypropylene stress plates. Square Galvalume® coated 3" Square steel plate. Manufacturer Dimensions (With Current NOA) Various GAF Materials Corp. Various GAF Materials Corp. Various GAF Materials Corp. 3" and 3 %2" GAF Materials Corp. 3" and 3 %z" GAF Materials Corp. OMG Test Identifier Description Date 3029832 4470 -TAS 114 05.11.07 3010215 4470 - TAS 114 03.01.01 3001276 4470 - TAS 114 0128.99 1B9A8.AM 4470 - TAS 114 09.04.97 3D4Q2.AM 4470 - TAS 114 04.30.97 OD1A8.AM 4470 - TAS 114 04.01.98 TGFU.R19254 UL 790 10.27.06 4483.04 97 -1 TAS 114 06.06.97 GAF - 020 -02 -01 ASTM D 249 02.01.02 ASTM D 4977 02 -005 TAS 114 03.01.02 02 -014 TAS 114 04.08.02 01 -039 TAS 114 03.01.02 NOA No.: 07- 1203.01 Expiration Date: 11/06/13 Approval Date: 03/06/08 Page 7 of 30 APPROVED ASSEMBLIES Membrane Type: Deck Type 1I: Deck Description: System Type A(1): SBS Wood, Insulated 19/32" or greater plywood or wood plank Anchor sheet mechanically fastened, all layers of insulation adhered with approved asphalt. All General and System Limitations shall apply. One or more layers of any of the following insulations. Insulation Layer Insulation Fasteners (Table 3) EnergyGuardrM Polylso, RA, RN, EnergyGuardTM Composite RA, Minimum 1" thick N/A Fastener Density /ft2 N/A Wood Fiber, EnergyGuardTM High Density Wood Fiber, EnergyGuardTM Recover Board Minimum 1 /�" thick N/A N/A EnergyGuardTM Perlite Minimum 3/4" thick N/A N/A Note: All insulation shall be adhered to the anchor sheet in full mopping of approved hot asphalt within the EVT range and at a rate of 20-40 lbs /100 ft2. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulation listed as base layer only shall be used only as base layers with a second layer of approved top layer insulation installed as the final membrane substrate. Composite insulation panels may be used as a top layer placed with the polyisocyanurate side facing down. GAF requires either a ply of GAFGLAS STRATAVENT® Eliminator Perforated laid dry or a layer of EnergyGuardTM, Perlite or wood fiber overlay board on all polyisocyanurate applications. Fire Barrier: FireOutTM Fire Barrier Coating, VersaShield ®Non- Asphaltic Fiberglass -Based (optional) Underlayment or SecurockTM. Anchor sheet: GAFGLAS® #80 ULTIMATM Base Sheet, STRATAVENT® EliminatorTM Nailable Base Sheet, RUBEROID® Modified Base Sheet, RUBEROID® 20, RUBEROID® SBS Heat- We1dTM Smooth or RUBEROID® SBS Heat- We1dTM 25 base sheet mechanically fastened to deck as described below; Fastening GAFGLAS® Ply 4, GAFGLAS® Flex P1yTM 6, GAFGLAS® #75 Base Sheet or any Options: of above Anchor sheets attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" o.c. at the lap staggered and in two rows 12" o.c. in the field. (Maximum Design Pressure —.45 psi; See General Limitation #7) GAFGLAS® Ply 4, GAFGLAS® Flex PIyTM 6, GAFGLAS® #75 Base Sheet or any of above Anchor sheets attached to deck with Drill-TecTM #12 standard, #14 or # 15 Screws and 3" Drill -TecTM steel plate or Drill -TecTM AccuTrac Plates, 12" o.c. in 3 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 12" o.c. in the field of the sheet. (Maximum Design Pressure —45 psf, See General Limitation #7) NOA No.: 07- 1203.01 Expiration Date: 11/06/13 Approval Date: 03/06/08 Page 8 of 30 GAFGLAS® Flex PiyTM 6, GAFGLAS® #75 Base Sheet or any of above Anchor sheets attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" o.c. at the 4" lap staggered and in two rows 9" o.c. in the field. (Maximum Design Pressure —52.5 psf, See General Limitation #7) GAFGLAS® #80 ULTIMATM, RUBEROID®20, RUBEROID ®Mop Smooth, base sheet attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" o.c. at the 4" lap staggered and in two rows 9" o.c. in the field. (Maximum Design Pressure —60 psf, See General Limitation #7) GAFGLAS® #75 Base Sheet or any of above Anchor sheets attached to deck with Drill -TecTM #12 standard, #14 or # 15 Screws and 3" Drill -TecTM steel plate•or Drill -TecTM AccuTrac Plates, 12" o.c. in 4 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 9" o.c. in the field of the sheet. (Maximum Design Pressure —60 psf, See General Limitation #7) Any of above Anchor sheets attached to deck approved annular ring shank nails and 3" inverted Drill -TecTM insulation plates at a fastener spacing of 9" o.c. at the 4" lap staggered in two rows 9" in the field. (Maximum Design Pressure —60 psf, See General Limitation #7) GAFGLAS® #75 Base Sheet or any of above Anchor sheets attached to deck with Drill -TecTM #12 standard, #14 or # 15 Screws and 3" Drill -TecTM steel plate or Drill-TecTM AccuTrac Plates, 8" o.c. in 4 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 9" o.c. in the field of the sheet. (Maximum Design Pressure —75 psf, See General Limitation #7) Base Sheet: (Optional) Install one ply of GAFGLAS® #75, GAFGLAS® #80 ULT1MATM Base Sheet, GAFGLAS® PLY 4, GAFGLAS Flex PIyTM 6, GAFGLAS® STRATAVENT® EliminatorTM Perforated (laid dry), RUBEROID® Modified Base Sheet, RUBEROID® MOP Smooth, RUBEROID® 20, RUBEROID® SBS Heat - WeIdTM Smooth or RUBEROID® SBS Heat- We1dTM 25 directly over the top layer of insulation. Adhere with any approved mopping asphalt applied within the EVT range and at a rate of 20-40 lbs. /sq (see General Limitation #4). Ply Sheet: (Optional) One or more plies GAFGLAS® PLY 4, GAFGLAS® Flex P1yTM 6 sheet, GAFGLAS® #80, RUBEROID® MOP Smooth, RUBEROIDo 20 adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20- 401bs. /sq. Membrane: One or more1lies of RUBEROID® 20, RUBEROID® 30, RUBEROID® 30 FR RUBEROID® MOP Smooth, RUBEROID® Mop 170 FR, RUBEROID® Mop Granule, RUBEROID® MOP PLUS, RUBEROID® MOP FR, RUBEROID® ULTRACLAD ®, or RUBEROID® Dual FR fully adhered in an approved asphalt at an application rate of 25 lb. /sq. ± 15 %. NOA No.: 07- 1203.01 Expiration Date: 11/06/13 Approval Date: 03/06/08 Page 9 of 30 Surfacing: (Optional, required if RUBEROID® MOP Smooth or RUBEROID® 20 is top membrane) Install one of the following: 1. Gravel or slag applied at 400 lbs. /sq. and 300lbs. /sq. respectively in a flood coat of approved asphalt at 60lbs. /sq. or applied in a flood coat of Leak BusterTM MatrixTM 103 Cold Process Adhesive applied at a rate of 3 gal. /sq. 2. GAFGLAS® Mineral Surfaced Cap Sheet, GAFGLAS® Energy Cap Mineral Surfaced Capsheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20 -40 lbs. /sq. 3. Leak BusterTM MatrixTM 303 Premium Fibered Aluminum Roof Coating, at 1.5 gal. /sq. 4. Leak BusterTM MatrixTM 715 , Leak BusterTM MatrixTM 322, TOPCOAT® MB +, TOPCOAT® Fireshield Elastomeric Roofing Membrane, applied at 1 to 1.5 gal. /sq. 5. Leak BusterTM MatrixTM 602 MB Xtra Elastomeric Roofmg Membrane, EnergyCote® roof coating applied at 1 to 1.5 gal./sq. 6. TOPCOAT® Surface Seal, TOPCOAT® Fireshield® SB Solvent based Elastomeric Roofing Membrane applied at lto 1.5 galisq 7. Advance Green Technologies Photovoltaic Laminate solar energy collector auxiliary roof equipment installed in compliance with manufacturer's specifications and applicable Building Codes. Maximum Design Pressure: MIAM WADE COUNTY APPROVED See Fastening Above NOA No.: 07- 1203.01 Expiration Date: 11/06/13 Approval Date: 03/06/08 Page 10 of 30 Membrane Type: APP /SBS Heat Weld Deck Type 1I: Wood, Insulated Deck Description: 19/32" or greater plywood or wood plank System Type A(2): Anchor sheet mechanically fastened, all layers of insulation adhered with approved asphalt. All General and System Limitations shall apply. One or more layers of any of the following insulations. Insulation Layer Insulation Fasteners Fastener (Table 3) Density /ft2 EnergyGuardTM RA, EnergyGuardTM RA Composite Minimum 1" thick N/A N/A Wood Fiber, EnergyGuardTM High Density Wood Fiber, EnergyGuardTM RecoverBoard Minimum %2" thick N/A N/A EnergyGuardTM Perlite Minimum 3/4" thick N/A N/A Note: All insulation shall be adhered to the anchor sheet in full mopping of approved hot asphalt within the EVT range and at a rate of 20-40 lbs /100 ft2. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulation listed as base layer only shall be used only as base layers with a second layer of approved top layer insulation installed as the fmal membrane substrate. Composite insulation panels may be used as a top layer placed with the polyisocyanurate side facing down. GAF requires either a ply of GAFGLAS® STRATAVENT® EliminatorTM perforated laid dry or a layer of EnergyGuardTM Perlite or EnergyGuardTM wood fiber overlay board on all polyisocyanurate applications. Fire Barrier: FireOutTM Fire Barrier Coating, VersaShield® Non - Asphaltic Fiberglass -Based (optional) Underlayment or SecurockTM. Anchor sheet: GAFGLAS® #80 ULTIMA TM Base Sheet, STRATAVENT® EliminatorrM Nailable, RUBEROID® Modified Base Sheet, RUBEROID® 20, RUBEROID® SBS Heat- We1dTM Smooth or RUBEROID® SBS Heat- WeldTM 25 base sheet mechanically fastened to deck as described below; Fastening GAFGLAS® Ply 4, GAFGLAS® Flex P1yTM 6, GAFGLAS® #75 Base Sheet or any Options: of above Anchor sheets attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" o.c. at the lap staggered and in two rows 12" o.c. in the field. (Maximum Design Pressure —45 psf, See General Limitation #7) GAFGLAS® Ply 4, GAFGLAS® Flex P1yTM 6, GAFGLAS® #75 Base Sheet or any of above Anchor sheets attached to deck with Drill -TecTM #12 standard, #14 or # 15 Screws and 3" Drill -TecTM steel plate or Drill -TecTM AccuTrac Plates, 12" o.c. in 3 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 12" o.c. in the field of the sheet. (Maximum Design Pressure —45 psf, See General Limitation #7) NOA No.: 07- 1203.01 Expiration Date: 11/06/13 Approval Date: 03/06/08 Page 11 of 30 GAFGLAS® Flex P1yTM 6, GAFGLAS® #75 Base Sheet or any of above Anchor sheets attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" o.c. at the 4" lap staggered and in two rows 9" o.c. in the field. (Maximum Design Pressure 52.5 psf, See General Limitation #7) GAFGLAS® #80 ULTIMATM, RUBEROID® 20, RUBEROID® Mop Smooth, base sheet attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" o.c. at the 4" lap staggered and in two rows 9" o.c. in the field. (Maximum Design Pressure —60 psf, See General Limitation #7) GAFGLAS® #75 Base Sheet or any of above Anchor sheets attached to deck with Drill-TecTM #12 standard, #14 or # 15 Screws and 3" Drill-TecTM steel plate or Drill-TecTM AccuTrac Plates, 12" o.c. in 4 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 9" o.c. in the field of the sheet. (Maximum Design Pressure —60 psf, See General Limitation #7) Any of above Anchor sheets attached to deck approved annular ring shank nails and 3" inverted Drill-TecTM insulation plates at a fastener spacing of 9" o.c. at the 4" lap staggered in two rows 9" in the field. (Maximum Design Pressure —60 psf, See General Limitation #7) GAFGLAS® #75 Base Sheet or any of above Anchor sheets attached to deck with Drill -TecTM #12 standard, #14 or # 15 Screws and 3" Drill -TecTM steel plate or Drill -TecTM AccuTrac Plates, 8" o.c. in 4 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 9" o.c. in the field of the sheet. (Maximum Design Pressure —75 psf, See General Limitation #7) Base Sheet: Install one ply of GAFGLAS® #75, GAFGLAS® #80 ULTIMATM Base Sheet, GAFGLAS® PLY 4, GAFGLAS® Flex PIyTM 6, GAFGLAS® STRATAVENT® EliminatorTM Perforated (laid dry), RUBEROID® Modified Base Sheet, RUBEROID® MOP Smooth, RUBEROID® 20, RUBEROID® SBS Heat We1dTM Smooth or RUBEROID® SBS Heat- We1dTM 25 directly over the top layer of insulation. Adhere with any approved mopping asphalt applied within the EVT range and at a rate of 20-40 lbs. /sq (see General Limitation #4). Ply Sheet: (Optional except over RUBEROID® Modified Base Sheet, RUBEROID® MOP Smooth, RUBEROID® 20, RUBEROID® SBS Heat- We1dTM Smooth or RUBEROID® SBS Heat- WeIdTM) One or more plies GAFGLAS® PLY 4, GAFGLAS® PLY 6 Ply or GAFGLAS® Flex PIyTM 6 sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs.sq. or RUBEROID® Torch Smooth torch applied according to manufacturer's application instructions. NOA No.: 07- 1203.01 Expiration Date: 11/06/13 Approval Date: 03/06/08 Page 12 of 30 Membrane: Surfacing: Maximum Design Pressure: One ply of RUBEROID® Torch Smooth, RUBEROID® Torch Granule, RUBEROID® Torch Plus Granule or RUBEROID® Torch FR torch applied according to manufacturer's application instructions. Or One or more plies of RUBEROID® SBS Heat We1dTM PLUS, RUBEROID® SBS Heat- We1dTM PLUS FR, RUBEROID® SBS Heat- WeIdTM 170 FR, RUBEROID®SBS Heat- We1dTM, RUBEROID® SBS Heat- We1dTM Smooth, RUBEROID® ULTRACLAD® SBS and RUBEROID® SBS Heat- We1dTM 25 • applied according to manufacturer's application instructions. (Optional, required if RUBEROID® MOP Smooth or RUBEROID® 20 is top membrane) Install one of the following: 1. Gravel or slag applied at 400 lbs./sq. and 300 lbs. /sq. respectively in a flood coat of approved asphalt at 60 lbs./sq. or applied in a flood coat of Leak BusterTM MatrixTM 103 Cold Process Adhesive applied at a rate of 3 gal. /sq. 2. GAFGLAS® Mineral Surfaced Cap Sheet, GAFGLAS® Energy Cap Mineral Surfaced Capsheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. 3. Leak BusterTM MatrixTM 303 Premium Fibered Aluminum Roof Coating, at 1.5 gal. /sq. 4. Leak BusterTM MatrixTM 715 , Leak Buster"' MatrixTM 322, TOPCOAT® MB +, TOPCOAT® Fireshield Elastomeric Roofing Membrane, applied at 1 to 1.5 gal. /sq. 5. Leak Buster"' MatrixTM 602 MB Xtra Elastomeric Roofing Membrane, EnergyCote® roof coating applied at 1 to 1.5 gal./sq. 6. TOPCOAT® Surface Seal, TOPCOAT® Fireshield® SB Solvent based Elastomeric Roofing Membrane applied at lto 1.5 gal./sq 7. Advance Green Technologies Photovoltaic Laminate solar energy collector auxiliary roof equipment installed in compliance with manufacturer's specifications and applicable Building Codes. See Fastening Above NOA No.: 07- 1203.01 Expiration Date: 11/06/13 Approval Date: 03/06/08 Page 13 of 30 Membrane Type: SBS Deck Type 1I: Wood, Insulated Deck Description: t9/32" or greater plywood or wood plank System Type B(1): Optional base sheet laid dry; base Layer of insulation mechanically fastened, optional top layer adhered with approved asphalt. All General and System Limitations shall apply. One or more layers of any of the following insulations. Base Insulation Layer Insulation Fasteners Fastener (Table 3) Density /ft2 EnergyGuardTM RA Minimum 1.3" thick 1, 2, or 3 1:3 ft2 EnergyGuardTM RN Minimum 1.4" thick 1, 2, or 3 1:3 ft2 EnergyGuardTM Minimum 1.3" thick 1, 2, or 3 1:3 ft2 EnergyGuardTM Minimum 1.5" thick 3 1:3 ft2 EnergyGuardTM Perlite Minimum %4" thick 1, or 3 1:2 ft2 Wood Fiber, EnergyGuardTM Fiberboard, EnergyGuardTM High Density Fiberboard Minimum 1" thick 1, 2, or 3 1:2 ft2 Note: Base layers of insulation shall be mechanically attached using the fastener density listed. The insulation panels listed are minimum sizes and dimensions; if larger panels are used, the number of fasteners shall be increased maintaining the same fastener density. Insulation fasteners shall be tested for withdrawal resistance in compliance with Protocol TAS 105 to confirm compliance with the wind load requirements. Please refer to Roofing Application Standard RAS 117 for insulation attachment. GAF requires either a ply of GAFGLAS STRATAVENT® EliminatorTM perforated laid dry or a layer of EnergyGuardTM Perlite or wood fiber overlay board on all polyisocyanurate applications. Top insulation Layer Insulation Fasteners Fastener (Table 3) Density /ft' Any of the insulation listed for Base Layer, above. High Density Wood Fiber, EnergyGuardTM High Density Wood Fiber, EnergyGuardTM Recover Board Minimum 1/2" thick N/A N/A Note: Optional top layer of insulation shall be adhered with approved asphalt within the EVT range and at a rate of 20-40 lbs/100 ft2. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Composite insulation boards used as a top layer shall be installed with the polyisocyanurate face down. NOA No.: 07- 1203.01 Expiration Date: 11/06/13 Approval Date: 03 /06/08 Page 14 of 30 Fire Barrier FireOutTM Fire Barrier Coating, VersaShield ®Non- Asphaltic Fiberglass -Based (optional) Underlayment or SecurockTM. Base Sheet: (Optional) Install one ply of GAFGLAS® #75, GAFGLAS® #80 ULTIMA M Base Sheet, GAFGLAS® PLY 4, GAFGLAS® Flex Ply' 6, GAFGLAS® STRATAVENT® EliminatorTM Perforated (laid dry), RUBEROID® Modified Base Sheet, RUBEROID® MOP Smooth or RUBEROID® 20 directly over the top layer of insulation. Adhere with any approved mopping asphalt applied within the EVT range and at a rate of 20-40 lbs. /sq; (see General Limitation #4). Ply Sheet: (Optional) One or more plies GAFGLAS® PLY 4, GAFGLAS Flex P1yT' 6 sheet or GAFGLAS® #80 ULTIMATM adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20- 401bs. /sq. Membrane: One or more plies of RUBEROID® 20, RUBEROID® 30, RUBEROID® 30 FR RUBEROID MOP Smooth, RUBEROID® Mop 170 FR, RUBEROID® Mop Granule, RUBEROID® MOP PLUS, RUBEROID® MOP FR, RUBEROID® Dual FR or RUBEROID® ULTRACLAD ®, fully adhered in an approved asphalt at an application rate of 25 lb. /sq. ± 15 %. Surfacing: Maximum Design Pressure: -45 psf; (See General Limitation #7) (Optional, required if RUBEROID® MOP Smooth or RUBEROID® 20 is top membrane) Install one of the following: 1. Gravel or slag applied at 400 lbs. /sq. and 300 lbsisq. respectively in a flood coat of approved asphalt at 60 lbs. /sq. or applied in a flood coat of Leak BusterTM MatrixTM 103 Cold Process Adhesive applied at a rate of 3 gal. /sq. 2. GAFGLAS® Mineral Surfaced Cap Sheet, GAFGLAS® Energy Cap Mineral Surfaced Capsheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbsisq. 3. Leak BusterTM MatrixTM 303 Premium Fibered Aluminum Roof Coating, at 1.5 gal. /sq. 4. Leak BusterTM MatrixTM 715 , Leak BusterTM MatrixTM 322, TOPCOAT® MB +, TOPCOAT® Fireshield Elastomeric Roofing Membrane, applied at 1 to 1.5 gal. /sq. 5. Leak BusterTM MatrixTM 602 MB Xtra Elastomeric Roofing Membrane, EnergyCote® roof coating applied at 1 to 1.5 gal. /sq. 6. TOPCOAT® Surface Seal, TOPCOAT® Fireshield® SB Solvent based Elastomeric Roofing Membrane applied at lto 1.5 gal. /sq 7. Advance Green Technologies Photovoltaic Laminate solar energy collector auxiliary roof equipment installed in compliance with manufacturer's specifications and applicable Building Codes. NOA No.: 07- 1203.01 Expiration Date: 11/06/13 Approval Date: 03/06/08 Page 15 of 30 Membrane Type: APP /SBS Heat Weld Deck Type 1I: Wood, Insulated Deck Description: 19/32" or greater plywood or wood plank. System Type B(2): Optional base sheet laid dry; base layer of insulation mechanically fastened, optional top layer adhered with approved asphalt. All General and System Limitations shall apply. One or more Layers of any of the following insulations. Base Insulation Layer Insulation Fasteners Fastener (Table 3) Density /ft2 EnergyGuardTM RA Minimum 1.3" thick 1, 2, or 3 1:3 ft2 EnergyGuardTM RN Minimum 1.4" thick 1, 2, or 3 1:3 ft2 EnergyGuardTM Minimum 1.3" thick 1, 2, or 3 1:3 ft2 EnergyGuardTM Composite EnergyGuardTM RA Composite Minimum 1.5" thick 3 1:3 ft2 EnergyGuardTM Perlite Minimum %" thick 1, or 3 1:2 ft2 Wood Fiber, EnergyGuardTM Fiberboard, EnergyGuardTM High Density Fiberboard Minimum 1" thick 1, 2, or 3 1:2 ft2 Note: Base layers of insulation shall be mechanically attached using the fastener density listed. The insulation panels listed are minimum sizes and dimensions; if larger panels are used, the number of fasteners shall be increased maintaining the same fastener density. Insulation fasteners shall be tested for withdrawal resistance in compliance with Protocol TAS 105 to confirm compliance with the wind load requirements. Please refer to Roofing Application Standard RAS 117 for insulation attachment. GAF requires either a ply of GAFGLAS® STRATAVENT® EliminatorTM perforated Laid dry or a layer of EnergyGuardTM Perlite or wood fiber overlay board on all polyisocyanurate applications. Top Insulation Layer Insulation Fasteners Fastener Any of the insulation listed for Base Layer, above. High Density Wood Fiber, EnergyGuardTM High Density Wood Fiber, EnergyGuardTM Recover Board Minimum 1/2" thick N/A N/A Note: Optional top layer of insulation shall be adhered with approved asphalt within the EVT range and at a rate of 20-40 lbs /100 ft2. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Composite insulation boards used as a top layer shall be installed with the polyisocyanurate face down. (Table 3) Density /ft2 NOA No.: 07- 1203.01 Expiration Date: 11/06/13 Approval Date: 03/06/08 Page 16 of 30 Fire Barrier: FireOutTM Fire Barrier Coating, VersaShield® Non - Asphaltic Fiberglass -Based (optional) Underlayment or SecurockTM. Base Sheet: Install one ply of GAFGLAS® #75, GAFGLAS® #80 ULTIMAT"I Base Sheet, GAFGLAS® PLY 4, GAFGLAS® Flex Ply' 6, GAFGLAS® STRATAVENT® EliminatorTM Perforated (laid dry), RUBEROID® Modified Base Sheet, RUBEROID® MOP Smooth, RUBEROID® 20, RUBEROID® SBS Heat- We1dTM Smooth or RUBEROID® SBS Heat- We1dTM 25 directly over the top layer of insulation. Adhere with any approved mopping asphalt applied within the EVT range and at a rate of 20-40 lbsisq; (see General Limitation #4). Ply Sheet: (Optional, required when using RUBEROID® 20) One or more plies GAFGLAS® PLY 4, GAFGLAS® Flex P1yTM 6 sheet or GAFGLAS® #80 ULTIMATM adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 Ibs. /sq. Membrane: One ply of RUBEROID® Torch Smooth, RUBEROID® Torch Granule, RUBEROID® Torch Plus Granule or RUBEROID® Torch FR torch applied according to manufacturer's application instructions. Or One or more plies of RUBEROID® SBS Heat- WeldTM PLUS, RUBEROID® SBS Heat- We1dTM PLUS FR, RUBEROID® SBS Heat- We1dTM 170 FR, RUBEROID® SBS Heat- WeldTM, RUBEROID® SBS Heat- WeldTM Smooth, RUBEROID® ULTRACLAD® SBS and RUBEROID® SBS Heat- We1dTM 25 applied according to manufacturer's application instructions. Surfacing: (Optional, required if RUBEROID® MOP Smooth or RUBEROID® 20 is top membrane) Install one of the following: 1. Gravel or slag applied at 400lbs. /sq. and 300 lbsisq. respectively in a flood coat of approved asphalt at 60 lbs. /sq. or applied in a flood coat of Leak BusterTM MatrixTM 103 Cold Process Adhesive applied at a rate of 3 gal./sq. 2. GAFGLAS® Mineral Surfaced Cap Sheet, GAFGLAS® Energy Cap Mineral Surfaced Capsheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs. /sq. 3. Leak BusterTM MatrixTM 303 Premium Fibered Aluminum Roof Coating, at 1.5 gal. /sq. 4. Leak BusterTM MatrixTM 715 , Leak BusterTM MatrixTM 322, TOPCOAT® MB +, TOPCOAT® Fireshield.Elastomeric Roofing Membrane, applied at 1 to 1.5 galisq. 5. Leak BusterTM MatrixTM 602 MB Xtra Elastomeric Roofing Membrane, EnergyCotee roof coating applied at 1 to 1.5 gal./sq. 6. TOPCOAT® Surface Seal, TOPCOAT® Fireshield® SB Solvent based Elastomeric Roofing Membrane applied at lto 1.5 galisq 7. Advance Green Technologies Photovoltaic Laminate solar energy collector auxiliary roof equipment installed in compliance with manufacturer's specifications and applicable Building Codes. Maximum Design Pressure: -45 psf;(See General Limitation #7) NOA No.: 07- 1203.01 Expiration Date: 11/06/13 Approval Date: 03/06/08 Page 17 of 30 Membrane Type: SBS Deck Type 1I: Wood, Insulated Deck Description: 19/32' or greater plywood or wood plank System Type C(1): One or more layers of insulation simultaneously attached; Base layer optional. All General and System Limitations shall apply. Base Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 EnergyGuardTM RA, EnergyGuardTM RN Minimum 1.3" thick N/A N/A EnergyGuardTM Minimum 1.4" thick N/A N/A EnergyGuardTM Composite, EnergyGuardTM RA Composite Minimum 1.5" thick N/A N/A EnergyGuardTM Perlite Minimum %" thick N/A N/A Wood Fiber, EnergyGuardTM Fiberboard Minimum 1" thick N/A N/A Note: All layers shall be simultaneously fastened; see top Layer below for fasteners and density. Insulation panels listed are minimum sizes and dimensions; if larger panels are used, the number of fasteners shall be increased maintaining the same fastener density. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Top Insulation Layer Insulation Fasteners Fastener EnergyGuard RA Minimum 1.3" thick EnergyGuardTM RN Minimum. 1.4" thick EnergyGuardTM RA, EnergyGuard Minimum 1.3" thick EnergyGuardTM Composite, EnergyGuardTM RA Composite Minimum 1.5" thick EnergyGuardTM Perlite Minimum %" thick (Table 3) Density/ft2 1, 2, or 3 1 :3 fit 1,2,or3 1:3ft2 1,2,or3 1:3ft2 3 1:3 ft2 1, or 3 1:2 ft2 1:2 ft2 EnergyGuardTM Fiberboard, EnergyGuardTM High Density Fiberboard Minimum 1" thick 1,2,or3 Note: Insulation panels listed are minimum sizes and dimensions; if larger panels are used, the number of fasteners shall be increased maintaining the same fastener density. Please refer to Roofing Application Standard RAS 117 for insulation attachment. GAF requires either a ply of GAFGLAr STRATAVENTc) EliminatorTM Perforated laid dry or a layer of EnergyGuardTM Perlite or wood fiber overlay board on all polyisocyanurate applications. NOA No.: 07- 1203.01 Expiration Date: 11/06/13 Approval Date: 03/06/08 Page 18 of 30 Fire Barrier: FireOutTM Fire Barrier Coating, VersaShield ®Non- Asphaltic Fiberglass -Based (optional) Underlayment or SecurockTM. Base Sheet: Install one ply of GAFGLAS® #75, GAFGLAS® # ULTIMA TM Base Sheet GAFGLAS® PLY 4, GAFGLAS® Flex•lim 6, GAFGLAS® STRATAVENT® Perforated (laid dry), RUBEROID® Modified Base Sheet, RUBEROID® MOP Smooth or RUBEROID® 20 directly over the top layer of insulation. Adhere with any approved mopping asphalt applied within the EVT range and at a rate of 20-40 lbs. /sq. If base sheet is applied directly to polyisocyanurate insulation only a spot or strip mopped application as detailed in this approval the use of an overlay board is approved; (see General Limitation #4). Ply Sheet: (Optional) One or more plies GAFGLAS® PLY 4, GAFGLAS® Flex P1yTM.6 sheet or GAFGLAS® #80 ULTIMA TM adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 Ibs./sq. Membrane: One or more plies of RUBEROID® 20 , RUBEROID® 30, RUBEROID® 30 FR RUBEROID® MOP Smooth, RUBEROID® Mop 170 FR, RUBEROID® Mop Granule, RUBEROID® MOP PLUS, RUBEROID® MOP FR, RUBEROID® Dual FR or RUBEROID® ULTRACLAD ®, fully adhered in an approved asphalt at an application rate of 20- 40lbs. /sq. Surfacing: (Optional, required if RUBEROID® MOP Smooth or RUBEROID® 20 is top membrane) Install one of the following: 1. Gravel or slag applied at 400 lbs. /sq. and 300 lbsisq. respectively in a flood coat of approved asphalt at 60 lbs. /sq. or applied in a flood coat of Leak BusterTM MatrixTM 103 Cold Process Adhesive applied at a rate of 3 gal. /sq. 2. GAFGLAS® Mineral Surfaced Cap Sheet, GAFGLAS® Energy Cap Mineral Surfaced Capsheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20- 40lbs. /sq. 3. Leak BusterTM MatrixTM 303 Premium Fibered Aluminum Roof Coating, at 1.5 gal. /sq. 4. Leak BusterTM MatrixTM 715 , Leak BusterTM MatrixTM 322, TOPCOAT® MB +, TOPCOAT® Fireshield Elastomeric Roofing Membrane, applied at 1 to 1.5 galisq. 5. Leak BusterTM MatrixTM 602 MB Xtra Elastomeric Roofing Membrane, EnergyCote'I roof coating applied at 1 to 1.5 gal. /sq. 6. TOPCOAT® Surface Seal, TOPCOAT® Fireshield® SB Solvent based Elastomeric Roofing Membrane applied at Ito 1.5 galisq 7. Advance Green Technologies Photovoltaic Laminate solar energy collector auxiliary roof equipment installed in compliance with manufacturer's specifications and applicable Building Codes. Maximum Design Pressure: -45 psf;(See General Limitation #7) NOA No.: 07- 1203.01 Expiration Date: 11/06/13 Approval Date: 03/06/08 Page 19 of 30 Membrane Type: Deck Type 1I: Deck Description: APP /SBS Heat Weld Wood, Insulated 19/32" or greater plywood or wood plank System Type C(2): One or more layers of insulation simultaneously attached; Base layer optional. All General and System Limitations shall apply. Base Insulation Layer EnergyGuardTM, EnergyGuardTM RA, EnergyGuardTM RN Minimum 1.3" thick EnergyGuardTM Minimum 1.4" thick EnergyGuardTM Composite, EnergyGuardTM RA Composite Minimum 1.5" thick EnergyGuardTM Perlite, EnergyGuardTM Recover Board Minimum 3/4" thick EnergyGuardTM Fiberboard Minimum 1" thick N/A N/A Note: All layers shall be simultaneously fastened; see top Layer below for fasteners and density. Insulation panels listed are minimum sizes and dimensions; if larger panels are used, the number of fasteners shall be increased maintaining the same fastener density. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Top Insulation Layer Insulation Fasteners Fastener (Table 3) Density /ft2 N/A N/A N/A N/A N/A N/A • N/A N/A EnergyGuardTM RA Minimum 1.3" thick EnergyGuardTM RN Minimum 1.4" thick EnergyGuardTM Minimum 1.3" thick EnergyGuardTM Composite, EnergyGuardTM RA Composite Minimum 1.5" thick EnergyGuardTM Perlite Minimum 3/4" thick Insulation Fasteners Fastener (Table 3) Density/ft2 1,2,or3 1:3ft2 1,2,or3 1:3ft2 1, 2, or 3 1:3 ft2 3 1:3 ft2 1,or3 1:2ft2 EnergyGuardTM Fiberboard, EnergyGuardTM High Density Fiberboard Minimum 1" thick 1, 2 or 3 1:2 ft2 Note: Insulation panels listed are minimum sizes and dimensions; if larger panels are used, the number of fasteners shall be increased maintaining the same fastener density. Please refer to Roofing Application Standard RAS 117 for insulation attachment. GAF requires either a ply of GAFGLAS STRATAVENT® EliminatorTM Perforated Laid dry or a layer of EnergyGuardTM Perlite or wood fiber overlay board on all polyisocyanurate applications. NOA No.: 07- 1203.01 Expiration Date: 11/06/13 Approval Date: 03/06/08 Page 20 of 30 Fire Barrier: FireOutTM Fire Barrier Coating, VersaShield ®Non- Asphaltic Fiberglass -Based (optional) Underlayment or SecurockTM. Base Sheet: Install one ply of GAFGLAS® #75, GAFGLAS® # ULTIMA TM Base Sheet GAFGLAS® PLY 4, GAFGLAS® FIexP1yTM 6, GAFGLAS® STRATAVENT® EliminatorTM Perforated (laid dry), RUBEROID® Modified Base Sheet, RUBEROID® MOP Smooth or RUBEROID® 20 directly over the top layer of insulation. Adhere with any approved mopping asphalt applied within the EVT range and at a rate of 20 -40 lbs. /sq. If base sheet is applied directly to polyisocyanurate insulation only a spot or strip mopped application as detailed in this approval the use of an overlay board is approved; (see General Limitation #4). Ply Sheet: (Optional, required when using RUBEROID® 20) One or more plies GAFGLAS® PLY 4, GAFGLAS® Flex P1yTM 6 sheet or GAFGLAS® #80 ULTIMATM adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. Membrane: One ply of RUBEROID® Torch Smooth, RUBEROID® Torch Granule, RUBEROID® Torch Plus Granule or RUBEROID® Torch FR torch applied according to manufacturer's application instructions. Surfacing: Maximum Design Pressure: Or One or more plies of RUBEROID® SBS Heat- We1dTM PLUS, RUBEROID® SBS Heat- We1dTM PLUS FR, RUBEROID® SBS Heat- We1dTM 170 FR, RUBEROID® SBS Heat- We1dTM, RUBEROID® SBS Heat- WeidTM Smooth, RUBEROID® ULTRACLADSBS and RUBEROID® SBS Heat- We1dTM 25 applied according to manufacturer's application instructions. (Optional, required if RUBEROID® MOP Smooth or RUBEROID® 20 is top membrane) Install one of the following: 1. Gravel or slag applied at 400lbs. /sq. and 300 lbs. /sq. respectively in a flood coat of approved asphalt at 60 Ibs. /sq. or applied in a flood coat of Leak BusterT ' MatrixTM 103 Cold Process Adhesive applied at a rate of 3 galisq. 2. GAFGLAS® Mineral Surfaced Cap Sheet, GAFGLAS® Energy Cap Mineral Surfaced Capsheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 Ibs./sq. 3. Leak BusterTM MatrixTM 303 Premium Fibered Aluminum Roof Coating, at 1.5 gal. /sq. 4. Leak BusterTM MatrixTM 715 , Leak BusterTM MatrixTM 322, TOPCOAT® MB +, TOPCOAT® Fireshield Elastomeric Roofing Membrane, applied at 1 to 1.5 gal. /sq. 5. Leak BusterTM MatrixTM 602 MB Xtra Elastomeric Roofing Membrane, EnergyCote® roof coating applied at 1 to 1.5 gal. /sq. 6. TOPCOAT® Surface Seal, TOPCOAT® Fireshield® SB Solvent based Elastomeric Roofing Membrane applied at lto 1.5 gal. /sq 7. Advance Green Technologies Photovoltaic Laminate solar energy collector auxiliary roof equipment installed in compliance with manufacturer's specifications and applicable Building Codes. -45 psf;(See General Limitation #7) NOA No.: 07- 1203.01 Expiration Date: 11/06/13 Approval Date: 03/06/08 Page 21 of 30 Membrane Type: SBS Deck Type 1I: Wood, Insulated Deck Description: 19/32" or greater plywood or wood plank System Type D(1): Insulation and Base sheet simultaneously attached All General and System Limitations shall apply. One or more layers of any of the following insulations. Insulation Layer Insulation Fasteners Fastener (Table 3) Density /ft2 EnergyGuardTM, EnergyGuardTM RA, EnergyGuardTM RA, EnergyGuardTM Composite, EnergyGuardTM High Density Fiberboard, EnergyGuardTM Fiberboard Minimum 1" thick N/A . N/A Fire Barrier: FireOutTM Fire Barrier Coating, VersaShield ®Non - Asphaltic Fiberglass -Based (optional) Underlayment or SecurockTM. Base Sheet: Install one ply of GAFGLAS® #75, GAFGLAS® #80 ULTIMATm Base Sheet, GAFGLAS® STRATAVENT® EliminatorTM Perforated or RUBEROID® 20 base sheet applied over the loose laid insulation with 2" side laps mechanically fastened to deck as described below; Fastening Options: Drill -TecTM #12 standard, #14 or # 15 Screws and 3" Drill -TecTM steel plate or Drill-TecTM AccuTrac Plates are installed through the base sheet and insulation in 3 rows 12" o.c. One row is in the 2" side lap. The other rows are equally spaced approximately 12" o.c. in the field of the sheet. (Maximum Design Pressure —45 psi; See General Limitation #7) GAFGLAS® #80 ULTIMATM, RUBEROID® 20, RUBEROID® Mop Smooth, base sheet attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" o.c. at the 4" lap staggered and in two rows 9" o.c. in the field. (.Maximum Design Pressure —60 psf, See General Limitation #7) Drill -TecTM #12 standard, #14 or # 15 Screws and 3" Plates in 4 rows 12" o.c. One row is in the 2" side lap. The other rows are equally spaced approximately 9" o.c. in the field of the sheet. (Maximum Design Pressure —60 psf, See General Limitation #7) Drill-TecTM #12 standard, #14 or # 15 Screws and 3" Drill -TecTM steel plate or Drill -TecTM AccuTrac Plates are installed through the base sheet and insulation in 4 rows 8" o.c. One row is in the 2" side lap. The other 3 rows are equally spaced approximately 9" o.c. in the field of the sheet. (Maximum Design Pressure —75 psi; See General Limitation #7) Ply Sheet: (Optional) One or more plies GAFGLAS® PLY 4, GAFGLAS® Flex PIyTM 6 sheet, GAFGLAS® #80 Uhlman", RUBEROID® MOP Smooth or RUBEROID® 20 adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 Ibs. /sq. NOA No.: 07- 1203.01 Expiration Date: 11/06/13 Approval Date: 03/06/08 Page 22 of 30 Membrane: Surfacing: One or more plies of RUBEROID® MOP Smooth, RUBEROID® Mop 170 FR, RUBEROID Mop Granule, RUBEROID® Mop Plus Granule, RUBEROID ®20, RUBEROID®30 or RUBEROID ®30 FR or RUBEROID® Mop FR or RUBEROID® ULTRACLAD® SBS in adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs. /sq. Or, One or more plies of RUBEROID® MOP Smooth, RUBEROID® Mop Granule, RUBEROID® Mop 170 FR, RUBEROID® Mop Plus Granule, RUBEROID® 20, RUBEROID® 30, RUBEROID® 30 FR or RUBEROID® Mop FR or RUBEROID® UL 1'RACLAD® SBS in RUBEROID® Modified Bitumen Adhesive at an application rate of 1 -2 gal./sq. (Optional, required if RUBEROID® MOP Smooth or RUBEROID® 20 is top - membrane) Install one of the following: 1. Gravel or slag applied at 400 lbsisq. and 300 lbsJsq. respectively in a flood coat of approved asphalt at 60 lbsisq. or applied in a flood coat of Leak BusterTM MatrixTM 103 Cold Process Adhesive applied at a rate of 3 gal. /sq. 2. GAFGLAS® Mineral Surfaced Cap Sheet, GAFGLAS® Energy Cap Mineral Surfaced Capsheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20- 40lbs.sq. 3. Leak BusterTM MatrixTM 303 Premium Fibered Aluminum Roof Coating, at 1.5 gal./sq. 4. Leak BusterTM MatrixTM 715 , Leak BusterTM MatrixTM 322, TOPCOAT® MB +, TOPCOAT® Fireshield Elastomeric Roofing Membrane, applied at 1 to 1.5 gal./sq. 5. Leak BusterTM MatrixTM 602 MB Xtra Elastomeric Roofing Membrane, EnergyCote® roof coating applied at 1 to 1.5 gal. /sq. 6. TOPCOAT® Surface Seal, TOPCOAT® Fireshield® SB Solvent based Elastomeric Roofing Membrane applied at lto 1.5 galisq 7. Advance Green Technologies Photovoltaic Laminate solar energy collector auxiliary roof equipment installed in compliance with manufacturer's specifications and applicable Building Codes. Maximum Design Pressure: See Fastening above NOA No.: 07- 1203.01 Expiration Date: 11/06/13 Approval Date: 03/06/08 Page 23 of 30 Membrane Type: APP /SBS Heat Weld Deck Type 1I: Wood, Insulated Deck Description: 19/32 ", or greater plywood or wood plank System Type D(2): Insulation and Base sheet simultaneously attached All General and System Limitations shall apply. One or more layers of any of the following insulations. Insulation Layer Insulation Fasteners Fastener (Table 3) Density /ft2 EnergyGuardTM, EnergyGuardTM RA, EnergyGuardTM Composite, Minimum 1.3" thick N/A N/A EnergyGuardTM High Density Fiberboard, EnergyGuardTM Fiberboard Minimum 1" thick N/A N/A Fire Barrier: FireOutTM Fire Barrier Coating, VersaShield ®Non - Asphaltic Fiberglass -Based (optional) Underlayment or SecurockTM. Base Sheet: Install one ply of GAFGLAS® #75, GAFGLAS® #80 ULTIMA TM Base Sheet, GAFGLAS® STRATAVENT® EliminatorTM Perforated or. RUBEROID® 20 base sheet applied over the loose laid insulation with 2" side laps mechanically fastened to deck as described below; Fastening Options: Drill -TecTM #12 standard, #14 or # 15 Screws and 3" Drill -TecTM steel plate or Drill -TecTM AccuTrac Plates are installed through the base sheet and insulation in 3 rows 12" o.c. One row is in the 2" side lap. The other rows are equally spaced approximately 12" o.c. in the field of the sheet. (Maximum Design Pressure —45 psf, See General Limitation #7) GAFGLAS® #80 ULTIMATM, RUBEROID® 20, RUBEROID® Mop Smooth, base sheet attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" o.c. at the 4" lap staggered and in two rows 9" o.c. in the field. (Maximum Design Pressure —60 psf, See General Limitation #7) Drill -TecTM #12 standard, #14 or # 15 Screws and 3" Drill -TecTM steel plate or Drill-TecTM AccuTrac Plates in 4 rows 12" o.c. One row is in the 2" side lap. The other rows are equally spaced approximately 9" o.c: in the field of the sheet. (Maximum Design Pressure —60 psf, See General Limitation #7) Drill-TecTM #12 standard, #14 or # 15 Screws and 3" Plates are installed through the base sheet and insulation in 4 rows 8" o.c. One row is in the 2" side lap. The other 3 rows are equally spaced approximately 9" o.c. in the field of the sheet. (Maximum Design Pressure —7S psf, See General Limitation #7) Ply Sheet: (Optional, required when using. RUBEROID® 20) One or more plies GAFGLAS® PLY 4, GAFGLAS® Flex P1yTM 6 sheet or GAFGLAS® #80 ULTIMATM adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs. /sq. NOA No.: 07- 1203.01 Expiration Date: 11/06/13 Approval Date: 03/06/08 Page 24 of 30 Membrane: Surfacing: Maximum Design Pressure: See Fastening Above One ply of RUBEROID® Torch Smooth, RUBEROID® Torch Granule, RUBEROID® Torch Plus Granule or RUBEROID® Torch FR torch applied according to manufacturer's application instructions. Or One or more plies of RUBEROID® SBS Heat- We1dTM PLUS, RUBEROID® SBS Heat- We1dTM PLUS FR, RUBEROID® SBS Heat- We1dTM 170 FR, RUBEROID® SBS Heat- WeIdTM, RUBEROID® SBS Heat- We1dTM Smooth, RUBEROID® ULTRACLAD® SBS and RUBEROID® SBS Heat- We1dTM 25 applied according to manufacturer's application instructions. (Optional, required if RUBEROID® MOP Smooth or RUBEROID® 20 is top membrane) Install one of the following: 1. Gravel or slag applied at 400 lbs. /sq. and 300lbs. /sq. respectively in a flood coat of approved asphalt at 60 lbs. /sq. or applied in a flood coat of Leak BusterTM MatrixTM 103 Cold Process Adhesive applied at a rate of 3 gal. /sq. 2. GAFGLAS® Mineral Surfaced Cap Sheet, GAFGLAS® Energy Cap Mineral Surfaced Capsheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20- 40lbs. /sq. 3. Leak BusterTM MatrixTM 303 Premium Fibered Aluminum Roof Coating, at 1.5 gal. /sq. 4. Leak BusterTM MatrixTM 715 , Leak BusterTM MatrixTM 322, TOPCOAT® MB +, TOPCOAT® Fireshield Elastomeric Roofing Membrane, applied at 1 to 1.5 gal. /sq. 5. Leak BusterTM MatrixTM 602 MB Xtra Elastomeric Roofing Membrane, EnergyCote'D roof coating applied at 1 to 1.5 gal./sq. 6. TOPCOAT® Surface Seal, TOPCOAT® Fireshield® SB Solvent based Elastomeric Roofing Membrane applied at lto 1.5 gal/qsq 7. Advance Green Technologies Photovoltaic Laminate solar energy collector auxiliary roof equipment installed in compliance with manufacturer's specifications and applicable Building Codes. NOA No.: 07- 1203.01 Expiration Date: 11/06/13 Approval Date: 03/06/08 Page 25 of 30 Membrane Type: Deck Type 1: Deck Description: System Type E(1): SBS /SBS Cold Applied Wood, Non - insulated 19/32" or greater plywood or wood plank decks Base sheet mechanically fastened to roof deck. All General and System Limitations shall apply. Fire Barrier: (optional) Base sheet: Fastening Options: FireOutTM Fire Barrier Coating, Versa Shield® Non-Asphaltic Fiberglass -Based Underlayment or SecurockTM. GAFGLAS® #80 ULTIMA TM Base Sheet, STRATAVENT® EliminatorTM Nailable, RUBEROID® Modified Base Sheet, RUBEROID® 20, RUBEROID® SBS Heat- We1dTM Smooth or RUBEROID® SBS Heat- WeIdTM 25 base sheet mechanically fastened to deck as described below; GAFGLAS® Ply 4, GAFGLAS® Flex PIyTM 6, GAFGLAS® #75 Base Sheet or any of above Base sheets attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" o.c. at the lap staggered and in two rows 12" o.c. in the field. (Maximum Design Pressure —45 psf, See General Limitation #7) GAFGLAS® Ply 4, GAFGLAS® Flex P1yTM 6, GAFGLAS® #75 Base Sheet or any of above Base sheets attached to deck with Drill-TecTM #12 standard, #14 or # 15 Screws and 3" Drill -TecTM steel plate or Drill -TecTM AccuTrac Plates, 12" o.c. in 3 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 12" o.c. in the field of the sheet. (Maximum Design Pressure —45 psf, See General Limitation #7) GAFGLAS® Flex PIyTM 6, GAFGLAS® #75 Base Sheet or any of above Base sheets attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" o.c. at the 4" lap staggered and in two rows 9" o.c. in the field. (Maximum Design Pressure 52.5 psf, See General Limitation #7) GAFGLAS® #80 ULTIMATM, RUBEROID ®20, RUBEROID® Mop Smooth, base sheet attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" o.c. at the 4" lap staggered and in two rows 9" o.c. in the field. (Maximum Design Pressure —60 psf, See General Limitation #7) GAFGLAS® #75 Base Sheet or any of above Base sheets attached to deck with Drill -TecTM 1112 standard, #14 or # 15 Screws and 3" Drill-TecTM steel plate or Drill -TecTM AccuTrac Plates, 12" o.c. in 4 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 9" o.c. in the field of the sheet. (Maximum Design Pressure —60 psf, See General Limitation #7) Any of above Base sheets attached to deck approved annular ring shank nails and 3" inverted Drill -TecTM insulation plates at a fastener spacing of 9" o.c. at the 4" lap staggered in two rows 9" in the field. (Maximum Design Pressure — 60psf, See General Limitation #7) NOA No.: 07- 1203.01 Expiration Date: 11/06/13 Approval Date: 03/06/08 Page 26 of 30 GAFGLAS® #75 Base Sheet or any of above Base sheets attached to deck with Drill -TecTM #12 standard, #14 or # 15 Screws and 3" Drill -TecTM steel plate or Drill -TecTM AccuTrac Plates, 8" o.c. in 4 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 9" o.c. in the field of the sheet. (Maximum Design .Pressure —75 psf, See General Limitation #7) Ply Sheet: (Optional) One or more plies GAFGLAS® PLY 4, GAFGLAS® Flex PlyTM 6, GAFGLAS® #80, RUBEROID® MOP Smooth or RUBEROID® 20 sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. Membrane: One or more plies of RUBEROID® MOP Smooth, RUBEROID® Mop 170 FR, RUBEROID Mop Granule, RUBEROID® Mop Plus Granule, RUBEROID®20, RUBEROID ®30 or RUBEROID®30 FR or RUBEROID® Mop FR or RUBEROID ULTRACLAD® SBS in adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbsisq. Or, One or more�plies. of RUBEROID® MOP Smooth, RUBEROID® Mop Granule, RUBEROID Mop 170 FR, RUBEROID® Mop Plus Granule, RUBEROID® 20, RUBEROID® 30, RUBEROID® 30 FR or RUBEROID® Mop FR or RUBEROID® ULTRACLAD® SBS in RUBEROID® Modified Bitumen Adhesive at an application rate of 1 -2 gal. /sq. Surfacing: (Optional, required if RUBEROID® MOP Smooth or RUBEROID® 20 is top membrane) Install one of the following: 1. Gravel or slag applied at 400 lbsisq. and 300lbs.sq. respectively in a flood coat of approved asphalt at 60 lbs.sq. or applied in a flood coat of Leak BusterTM MatrixTM 103 Cold Process Adhesive applied at a rate of 3 gal. /sq. 2. GAFGLAS® Mineral Surfaced Cap Sheet, GAFGLAS® Energy Cap Mineral Surfaced Capsheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs. /sq. 3. Leak BusterTM MatrixTM 303 Premium Fibered Aluminum Roof Coating, at 1.5 gal./sq. 4. Leak Buster"' MatrixTM 715 , Leak Buster"' MatrixTM 322, TOPCOAT® MB-+-, TOPCOAT® Fireshield Elastomeric Roofmg Membrane, applied at 1 to 1.5 galisq. 5. Leak BusterTM MatrixTM 602 MB Xtra Elastomeric Roofmg Membrane, EnergyCote® roof coating applied at 1 to 1.5 gal./sq. 6. TOPCOAT® Surface Seal, TOPCOAT® Fireshield® SB Solvent based Elastomeric Roofmg Membrane applied at lto 1.5 galisq 7. Advance Green Technologies Photovoltaic Laminate solar energy collector auxiliary roof equipment installed in compliance with manufacturer's specifications and applicable Building Codes. Maximum Design Pressure: See Fastening above NOA No.: 07- 1203.01 Expiration Date: 11/06/13 Approval Date: 03/06/08 Page 27 of 30 Membrane Type: APP /SBS Heat Weld Deck Type 1: Wood, Non - insulated Deck Description: 14/32" or greater plywood or wood plank decks System Type E(2): Base sheet mechanically fastened. All General and System Limitations shall apply. Fire Barrier: FireOutTM Fire Barrier Coating, VersaSldeld®Non-Asphaltic Fiberglass -Based (optional) Underlayment or SecurockTM. Base sheet: GAFGLAS® #80 ULTIMATM Base Sheet, STRATAVENT® Eliminator", Nailable, RUBEROID® Modified Base Sheet, RUBEROID® MOP Smooth, RUBEROID® 20, RUBEROID® SBS Heat-WeldTM Smooth or RUBEROID® SBS Heat -Weld 25 base sheet mechanically fastened to deck as described below; Fastening Options: GAFGLAS Ply 4, GAFGLAS® Flex PIym 6, GAFGLAS® #75 Base Sheet or any of above Base sheets attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" 0.0. at the lap staggered and in two rows 12" o.c. in the field. (Maximum Design Pressure —45 psf, See General Limitation #7) GAFGLAS® Ply 4, GAFGLAS Flex P1yTM 6, GAFGLAS® #75 Base Sheet or any of above Base sheets attached to deck with Drill -TecTM #12 standard, #14 or # 15 Screws and 3" Drill -TecTM steel plate or Drill-Teem AccuTrac Plates, 12" 0.0. in 3 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 12" o.c. in the field of the sheet. (Maximum Design Pressure --45 psf, See General Limitation #7) GAFGLAS® Flex P1yTM 6, GAFGLAS® #75 Base Sheet or any of above Base sheets attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" o.c. at the 4" lap staggered and in two rows 9" o.c. in the field. (Maximum Design Pressure —52.5 psf, See General Limitation #7) GAFGLAS® #80 ULTIMATM, RUBEROID®20, RUBEROID® Mop Smooth, base sheet attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" o.c. at the 4" lap staggered and in two rows 9" o.c. in the field. (Maximum Design Pressure —60 psf, See General Limitation #7) GAFGLAS® #75 Base Sheet or any of above Base sheets attached to deck with Drill -TecTM #12 standard, #14 or # 15 Screws and 3" Drill -TecTM steel plate or Drill -TecTM AccuTrac Plates, 12" o.c. in 4 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 9" o.c. in the field of the sheet. (Maximum Design Pressure —60 psf, See General Limitation #7) Any of above Base sheets attached to deck approved annular ring shank nails and 3" inverted Drill -TecTM insulation plates at a fastener spacing of 9" o.c. at the 4" lap staggered in two rows 9" in the field. (Maximum Design Pressure —60 psi, See General Limitation #7) APPROVED NOA No.: 07- 1203.01 Expiration Date: 11/06/13 Approval Date: 03/06/08 Page 28 of 30 GAFGLAS® #75 Base Sheet or any of above Base sheets attached to deck with Drill-TecTM #12 standard, #14 or # 15 Screws and 3" Drill -TecTM steel plate or Drill -TecTM AccuTrac Plates, 8" o.c. in 4 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 9" o.c. in the field of the sheet. (Maximum Design Pressure —75 psf, See General Limitation #7) Ply Sheet: (Optional except over RUBEROID® Modified Base Sheet, RUBEROID® MOP Smooth, RUBEROID® 20, RUBEROID® SBS Heat We1dTM Smooth or RUBEROID® SBS Heat- WeIdTM) One or more plies GAFGLAS® PLY 4 or GAFGLAS® Flex PIyTM 6 sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs. /sq. or RUBEROID® Torch Smooth torch applied according to manufacturer's application instructions. Membrane: One ply of RUBEROID® Torch Smooth, RUBEROID® Torch Granule, RUBEROID® Torch Plus Granule or RUBEROID® Torch FR torch applied according to manufacturer's application instructions. Or One or more plies of RUBEROID® SBS Heat- WeIdTM PLUS, RUBEROID® SBS Heat- We1dTM PLUS FR, RUBEROID® SBS Heat- We1dTM 170 FR, RUBEROID® SBS Heat- We1dTM, RUBEROID® SBS Heat- We1dTM Smooth, RUBEROID® ULTRACLAD® SBS and RUBEROID® SBS Heat- We1dTM 25 applied according to manufacturer's application instructions. Surfacing: (Optional, required if RUBEROID® MOP Smooth or RUBEROID® 20 is top membrane) Install one of the following: 1. Gravel or slag applied at 400 lbs. /sq. and 300 lbs. /sq. respectively in a flood coat of approved asphalt at 60 Ibsisq. or applied in a flood coat of Leak BusterTM MatrixTM 103 Cold Process Adhesive applied at a rate of 3 gal. /sq. 2. GAFGLAS® Mineral Surfaced Cap Sheet, GAFGLAS® Energy Cap Mineral Surfaced Capsheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs. /sq. 3. Leak Buster"M MatrixTM 303 Premium Fibered Aluminum Roof Coating, at 1.5 gal. /sq. 4. Leak BusterTM MatrixTM 715 , Leak Buster"M MatrixTM 322, TOPCOAT® MB +, TOPCOAT® Fireshield Elastomeric Roofmg Membrane, applied at 1 to 1.5 gal. /sq. 5. Leak BusterTM MatrixTM 602 MB Xtra Elastomeric Roofing Membrane, EnergyCotee roof coating applied at 1 to 1.5 gal. /sq. 6. TOPCOAT® Surface Seal, TOPCOAT® Fireshield® SB Solvent based Elastomeric Roofing Membrane applied at lto 1.5 galisq 7. Advance Green Technologies Photovoltaic Laminate solar energy collector auxiliary roof equipment installed in compliance with manufacturer's specifications and applicable Building Codes. Maximum Design Pressure: See Fastening Above NOA No.: 07- 1203.01 Expiration Date: 11/06/13 Approval Date: 03/06/08 Page 29 of 30 WOOD DECK SYSTEM LIMITATIONS: 1 A slip sheet is required with Ply 4 and Flex Ply TM 6 when used as a mechanically fastened base or anchor sheet. 2. Minimum 1/" Dens Deck or y" Type X gypsum board is acceptable to be installed directly over the wood deck. GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance; refer to a current Approved Roofmg Materials Directory for fire ratings of this product. 2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs. /sq., or mechanically attached using the fastening pattern of the top layer 3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size shall be 4' x 4' maximum. 4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at each side lap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 12 lbsisq. Note: Spot attached systems shall be limited to a maximum design pressure of -45 psf. 5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F) value of 275 lbf., as tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field - tested, are below 275 lbf. insulation attachment shall not be acceptable. 6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing, prepared, signed and sealed by a Florida Registered Engineer, Architect, or Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117. 7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred within this NOA, General Limitation #9 will not be applicable.) 8. All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs shall conform to Roofmg Application Standard RAS 111 and applicable wind load requirements. 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended comers and corners). (When this limitation is specifically referred within this NOA, General Limitation #7 will not be applicable.) 10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9B -72 of the Florida Administrative Code. END OF THIS ACCEPTANCE NOA No.: 07- 1203.01 Expiration Date: 11/06/13 Approval Date: 03/06/08 Page 30 of 30 2004 ROOFING MATERIALS ARC SYSTEMS DIVnECTpn`I ROOF COVERING MATERIALS (TEVT) Roofing Systems (TGFU)— Continued ulation: Perlite, glass fiber or wood fiber, 3/4 to 1-1/2 in. embrane: 'Ruberoid Torch Granule 1" (modified bitumen). urfadng: Gravel at 400 lbs /sq, loose laid or concrete blocks, at 10 /sq and spaced not more than 1/8 in. NC Incline: 3 Insulation (Optional): Perlite, glass fiber or wood fiber, 3/4 to 1-1/2 in ase Sheet (Optional): Type 15 asphalt organic felt or Type G2. Membrane: "Ruberoid Torch Granule 1" (modified bitumen). Surfacing: Gravel. ecic C -15/32 Incline: 1/4 Insulation (Optional): Perlite, glass fiber or wood fiber, any thickness. Membrane: "Ruberoid Torch Granule 1" (modified bitumen). Slip Sheet: 0.004 in. polyethylene (not UL Classified). Surfacing 3/4 in. thick concrete with one layer of No. 10 Summerville Quarry tile (or equivalent) grouted in place. Decks NC Incline: 2 Insulation (Optional): Perlite, glass fiber or wood fiber, any thickness Membrane "Ruberoid Torch Granule 1" (modified bitumen). Surfacing: 3/4 to 1 -1/2 in. diam river bottom stone at 1000 lb /sq or concrete pavers weighing not less than 10 lb /sq ft and spaced not more than 1/8 in Decic NC Incliner 3 Insulation: a)Polystyrene, 2 in. max, b)Isocyanurate, any thickness, laid loosely. Membrane "EverGuard SR" or "EverGuard FB ", 40-100 mil (TPA), laid loosely. Surfacing; River bottom stone (3/4 - 1 -1/2 in. diam) at 1000 Ib /sq or concrete roof pavers. Deck C -15/32 Incline: 1/2 Slip Sheet One or more layers Atlas Roofing "FR50 ", mechanically fastened. Membrane. "BverGuard TPO2 Plus ", 45 mil. Surfacing; River bottom stone, (3/4 to 1 -1/2 in. diam) at 1000 Ibs /sq or concrete roof pavers. Deck C -15/32 Incline: 1/2 Base Sheet Two or more layers Type G2, "GAFGLAS Basesheet #i75 ", mechanically fastened. Membrane "EverGuard TP02 Plus ", 45 mil. Surfacing: River bottom stone, (3/4 to 1 -1/2 in. diam) at 1000 lbs /sq or concrete roof pavers. Class A • Fully Adhered I. Deck: NC Incline: 1/2 Insulation (Optional): One or more layers perlite, wood fiber, glass fiber, isocyanurate, urethane, perlite / isocyanurate composite, perlite/ urethane composite, wood fiber /isocyanurate composite, phenolic, any thickness. Base Sheet (Optional): One or more layers Type Gl, G2 or G3. Membrane One or more layers "Ruberoid Torch" (Smooth or Granule), "Ruberoid Torch Granule Plus ", "Ruberoid Mop" (Smooth or Granule) or "Ruberoid Mop Plus Granule" (granule). Surfacing: Gravel, 400 lbs /sq, loose laid or applied in a flood coat of hot roofing asphalt. 2. Deck: NC Incline: 1/2 Base Sheet (Optional): One or more layers Type Gl, G2 or G3. Membrane. One or more layers 'Ruberoid Torch" (Smooth or Granule), "Ruberoid Torch Granule Plus ", 'Ruberoid Mop" (Smooth or Granule) or "Ruberoid Mop Plus Granule ". Coating: Karnak No. 97, 1 -1/2 - 3 gal /sq. 3. Deck NC Incline: 1 /4 Insulation (Optional): One or more lavers perlite, wood fiber, glass fiber, any thickness. Base Sheet (Optional): One or more layers Type Gl, G2 or G3. Membrane: One or more lavers "Ruberoid Torch" (Smooth or Granule). "Ruberoid Torch Granule Plus ", "Ruberoid Mop Granule" Or "Ruberoid Mop Plus Granule ". Coating: Karnak No. 97, 1 -1/2 - 3 gal / sq. 4. Deck: C -15/32 Incline 1/2 Insulation: One or more layers perlite, glass fiber, isocyanurate, ure- thane, perlite / isocyanurate composite, perlite /urethane composite, phe- nolic, 1 -1/2 in. min thickness (offset from plywood joints 6 in.). Base Sheet One or more layers Type G2 or G3. Ply Sheet (Optional): One or more layers Type Gl. ROOF COVERING MATERIALS (TEVT) 175 Roofing Systems (TGFU)— Continued Membrane: One or more layers "Ruberoid Torch' (Smooth or Granule) 'Ruberoid Torch Granule Plus ", "Ruberoid Mop" (Smooth or Granule or "Ruberoid Mop Plus Granule ". Surfacing: Karnak No 97, 1 -1/2 - 3 gal /sq. 5. Deck: NC Incline: 1/2 Base Sheet (Optional): One or more layers Type Gi, G2 or G3. Membrane: One or more layers "Ruberoid Torch" (Smooth or Granule) "Ruberoid Torch Granule Plus ". Surfacing (Optional): Karnak "No. 97" or "169" at 1 -3 gal / sq or Grundy Ind. "20 F Emulsion" at 3 gal /sq. 6. Deck: C -15/32 Incline: 1/2 Insulation: One or more layers perlite, glass fiber, 3/4 in. min, isocya- nurate, urethane, perlite / isocyanurate composite, perlite /urethane com- posite, 1 -1/2 in. min. Base Sheet (Optional): One or more layers Type Gl, G2 or G3. Membrane: One or more layers "Ruberoid Torch" (Smooth or Granule), "Ruberoid Torch Granule Plus ", "Ruberoid Mop" (Smooth or Granule) or "Ruberoid Mop Plus Granule ". Surfacing: Gravel. 7. Deck: C -15/32 Incline: 1/2 Insulation (Optional): One or more layers perlite, wood fiber, glass fiber, isocyanurate, urethane, perlite / isocyanurate composite, perlite/ urethane composite, wood fiber / isocyanurate composite. Base Sheet Two or more layers Type G2 or G3. Ply Sheet (Optional): One or more layers Type GI. Membrane: One or more layers "Ruberoid Torch" (Smooth or Granule), "Ruberoid Torch Granule Plus ", "Ruberoid Mop" (Smooth or Granule) or "Ruberoid Mop Plus Granule ". Surfadng: Karnak No. 97, 1-1/2 - 3 gal /sq or gravel. 8. Deck: NC Incline: 1/2 Insulation: One or more layers perlite, glass fiber, 3/4 in. min, isocya- nurate, urethane, perl ite / isocyanurate composite, perlite /urethane com- posite, 1 -1/2 in. min. Base Sheet (Optional): One or more layers Type G1, G2 or G3. Membrane: One or more layers "Ruberoid Torch" (Smooth or Granule), "Ruberoid Torch Granule Plus ", "Ruberoid Mop" (Smooth or Granule) or "Ruberoid Mop Plus Granule ". Surfacing: Grundy "AL MB Aluminum Roof Coating" at 1 -2 gal /sq. 9. Deck: C -15/32 Incline: 1 /2 Insulation (Optional): One or more layers perlite, glass fiber, 3/4 in. min, isocyanurate, urethane, perlite / isocyanurate composite, perlite/ urethane composite, phenolic, 1 -1/2 in. min. Base Sheet: One or more layers Type G2 "GAFGLAS e75 Base Sheet ", hot mopped or mechanically fastened in place. Ply Sheet One or more layers Type G1 " GAFGLAS Ply 4 ", hot mopped in place. Membrane "Ruberoid Mop 170 FR ". Surfacing (Optional): "GAF Fibered Aluminum Coating' at 1 -1/2 gal /sq or "GAF Weather Coat Emulsion" at 3 gal /sq. 10. Deleted 11. Deleted 12. Deleted 13. Deleted 14. Deleted 15. Deck: C -15/32 Incline: 1/2 Insulation (Optional): perlite, fiber glass, isocyanurate, urethane or perlite/ isocyanurate composite. Base Sheet One or more layers Type G2 or G3 base sheet, hot mopped or mechanically fastened. Ply Sheet (Optional): One or more layers Type Gi, hot mopped in place. Membrane: "Ruberoid Mop 170 FR ". 16. Deck: C -13/32 Incline: 1/2 Insulation (Optional): perlite; fiber glass, isocyanurate, urethane or perlite / isocyanurate composite, offset 6 M. from joints. Base Sheet: One or more lavers Type G -2 or G -3 base sheet, hot mopped or mechanically fastened. Ply Sheet (Optional): One or more layers Type G-1, hot mopped in place. Membrane: One layer "Ruberoid Torch Smooth" or "Ruberoid Mop Smooth ". Membrane: One layer "Ruberoid Mop 170 FR ". 17. Deck: NC Incline: 1 12/02/2008 09:43 3052586410 (r )>) 14' o?3 x/3 qs cY8 DENNIS ROOFING PAGE 03 GA1 LASS #75 Base Sheet or any of above Base sheets attached to deck with Drill -Teem #12 standard, #14 or # 15 Screws and 3" Drill -Teem steel plate or Drill-Tres AccuTrac Plates, 8" o.c. in 4 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 9" o.c, in the field of the sheet. (Maximums Design Pressure —75 psf, See General L W :a kin #7) re plies GAFGLASe PLY •1' AFGLAS® Flex PIyTM 6, Smooth or RUBERO1D 20 sheet adhered e EVT range and at a rate 6'�Membrane: lit 1 4 . replies of RUBEROID" MOP Smoo RUBEROID Mop Granule, RUBEROJDDMop Plus Granule, RIJBEROIDm20, RUBERO1'D" 30 or RUB$RWJDe 30 FR or RUBEROIDe Mop FR. or RUBEROID ULTRACLALP SB . adhered in a full mopping o :... • t applied within the EVT ran Or, One or more plies of RUBERROIDD MOP Smooth, RUBER.O.1De Mop Granule, RUBER0117 Mop 170 PR, RUBEROID" Mop Flux Granule, RTJBEROIDe20 RUBEROITP) 30, RUBEROIV930 FR or RUBEROID® Mop FR or RUBERO.IDe ULX'RACLADe SBS its RUBEROM" Modified Bitumen Adhesive at an application rate of 1 -2 gaI./sq. Surfacing: (Optional, required if RUBEROID® MOP Smooth or ROBEROV 20 is top membrane) Install one of the following: 1. Gravel or slag applied at 400 lbs./sq. and 300 Ibs.sq, respectively in a flood coat of approved asphalt at 60 lbs./sq. or applied in a Flood coat of Leak BusterTM MatrixTM 103 Cold Process Adhesive applied at a rate of 3 gal./sq. 2. GAFGLASe Mineral Surfaced Cap Sheet, GAFGLAS" Energy Cap Mineral Surfaced Capsheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rata of 20-40 lbs./sq. 3. Leak BusterlM MatrisTM 303 Premium Fibered Alurtsioun Roof Coating, at 1.5 galJsq. 4. Leak BusteriM Matrix lm 715 , Leak BusterTm Matrix*M 322, TOPCOAT" MB +, TOPCOAT" Fireshield Elastomeric Roofing Membrane, applied at 1 to 1.5 gal./sq. 5. Leak BusterTM MatrixTM 602 MB Xtra Elastomeric Roofing Membrane, EvergyCote® roof coating applied at 1 to 1.5 gel.sq, 6. TOPCOA14 Surface Seal, TOPCOAT' Fireshielde S.B Solvent based Elastomerie Roofing Membrane applied at Ito 1.5 gal./sq 7. Advance Green Technologies Photovoltaic Laminate solar energy collector auxiliary roof equipment. installed in compliance with adorer's specifications and applicable Building Codes. Maxbnum Design Pressure: See Fastening above •\11• NOA No 07- 1203.01 Expiration Date: 11/06/13 Approval Dates 03/06/08 Page 27 of 30 Miami Shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 Permit No. 67 F ciC� Job Name Date STRUCTURAL CRITIQUE SHEET (2) /44,/ 71-xe Ae‘e-filepzoe,reff a .1 47 e,e.A.--L ze," L ee #1,1�24 Z,1 ried-