Loading...
RCRT-5-10-984• Complete items 1, 2, and 3. Also complete item 4 if Restricted Delivery is desired. • Print your name and address on the reverse so that we can return the card to you. • Attach this card to the back of the mailpiece, or on the front if space permits. SENDER: COMPLETE THIS SECTION 1. Article Addressed to: MARRU5S CORP. 9q9S PPOZNA 19121VE.. M1AlkA\ 5Hotz-ES FL- 3313'i• - 31(0 3 2. Article Number (Transfer from service label) PS Form 3811, February 2004 U.S. Postal ServiceTM CERTIFIED MAILTM RECEIPT tDomestic Mail Only; No Insurance Coverage Provided) For delivery information visit our website at www.usps.com6 Postage Certified Fee Return Receipt Fee (Endorsement Required) Restricted Delivery Fee (Endorsement Required Total Postage & Fees Sent To wicok2t) 5 CORP. Street, Apt. No.; or PO Box No. 9 t5 ?ARA P. Postmark Here City, State, ZIP+4 MIMA\ ‘4-0e.e.S , 33 13? — 31(03 PS Form 3800. August 2006 See Reverse for Instructions COMPLETE THIS SECTION ON DELIVERY 3. Service Type 0 Certified Mail o Registered 0 Insured Mail Printed Name) "n4 D. Is delivery address different from item 1? 0 Yes If YES, enter delivery address below: 0 No 4. Restricted Delivery? (Extra Fee) 7009 1410 0000 7000 9927 gent dressee C. Data of Del 0 Express Mall 0 Retum Receipt for Merchandise 0 C.O.D. 0 Yes Domestic Return Receipt 102595-02-m-1540 BUILDING PERMIT APPLICATION FBC 20 Job Address (where the work is being done) Contact Phone Architect /Engineer's Name (if applicable) Notary $ Double Fee $ Violation date: Structural Review. $ Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 INSPECTION'S PHONE NUMBER: (305) 762.4949 Permit Type: B UILDING ROOFING 1 Owner's Name (Fee Simple Titleholder) !" 10 �' ; Phone # Owner's Address City State Zip Tenant/Lessee Name Email ❑Alteration Phone # allCoS Cbire-- e\C City Miami Shores Village County Miami -Dade FOLIO / PARCEL # 11 J 14-1 300 Is Building Historically Designated YES NO Training/Education Fee $ E -mail Scanning $ Radon $ DPBR $ Permit No. RCRT- - 9 Eti Master Permit No. Contractor's Company Name Contractor's Address City State Zip Qualifier Name Phone # State Certificate or Registration No. Certificate of Competency No. Phone # Phone # Value of Work For this Permit $ Square / Linear Footage Of Work: U i 114 Type of Work: EAddition Describe Work: ['New ❑ Repair/Replace ❑ Demolition ******** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** F * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Submittal Fee $ Permit Fee $ CCF $ CO /CC $ Total Fee Now Due $ Zip Flood Zone Technology Fee $ Bond $ See Reverse side Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature Signature Owner or Agent Contractor The foregoing instrument was acknowledged before me this The foregoing instrument was acknowledged before me this day of ,20 ,by , day of ,20_,by who is personally known to me or who has produced who is personally known to me or who has produced As identification and who did take an oath. as identification and who did take an oath. NOTARY PUBLIC: NOTARY PUBLIC: Sign: Sign: Print: Print: My Commission Expires: My Commission Expires: ***************************************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** APPROVED BY Plans Examiner Zoning (Revised 07 /l0 /07)(Revised 06/10/2009) Engineer Clerk checked 5/28/2010 Certified Mail # 7009 1410 0000 7000 9927 Property located at: Address: 9165 PARK Drive Miami Shores, Florida, 33138 -3163 Permit Number: RCRT - 5 - 10 - 984 Folio # Dear Owner: Sincerely, Norman Bruhn, Building Official 305- 795 -2204 MIAMI SHORES VILLAGE Building Department 10050 NE 2 Ave, Miami Shores Fl, 33138 Tel: 305-795-2204. Fax: 305- 756 -8972 Notice of Required Inspection/Certification The Village has been notified by Metro -Dade Building & Zoning Department that the above referenced property has a building or structure that is forty (40) years old or older. In accordance with Miami -Dade County Chapter 8 Section 8 -11, the subject property must be inspected by a Florida Registered Architect or Engineer and a report furnished to this office. A report and a fee of two - hundred fifty dollars must be submitted to this office within ninety (90) days of receiving this Notice of Required Inspection/Certification. If you would like a copy of Minimum Inspection Procedural Guidelines for Structural and Electrical Recertification, or if you have any questions, please call my office at 305- 795 -2204. e ige f fr - wo ova- FEB 5 ' 011 B� o Miami Shores Building Department 10050 Northeast 2nd Avenue Miami Shores, Florida 33139 ATKINS ENGINEERS, INC. 228 Artmc BOULEVARD, SurrE 400 KEY LARGO, FLORIDA 33037 KEYS 305.451.4556 305.451.4557 FAX MIAMI 305.444.6260 305.442.2201 FAX January 12, 2009 RE: 40 Year Building Safety Inspection Report - Structural Marruss Corporation A. R. Marsico 9165 Park Drive, Miami Shores, FL 33138 -3163 Atkins Engineers has performed a visual structural observation of the building referenced above. The building is one -story structure with masonry walls at exterior sides supporting pre -cast Double Tee Roof System and conventional built -Up Roofing. The floor is a concrete slab on grade. Based on our observations, the building appears to be in fair conditions. We are enclosing three copies of the Minimum Inspection Procedural Guidelines For Building's Structural Rcertification and Photographs on the above mentioned property. The comments and statements herein are to the best of my knowledge and refer to the existing condition of the building structure based on the observations we could perform and accessibility to the different locations of the building. If you should have any questions, please do not hesitate to contact us. Enclosures. Your truly, ;GINE An Tn.o Riva, PE. .P a /S6,S a. Name of Title: Marruss Corp -A.R. Marsico b. Street Address: 9165 Park . Dri ve, Mi ami Shores_, FL 33138-3163 c. Legal Description: Mi ami Shores Semi on 2_ PR 10-37 d. Owners Name: A.R. Mariso e. Owner's Mailing Address: 9165 Park Drive, _Mi ami Shores, FL __331 38 If. Folio Number of Building: 11-3206-014-1350 g. Building Code Occupancy Classification: Business Group B h. Present Use: professional Office Building i . General Description, Type of Construction, Size, Number of Stories, and Special Features Additional Comment: One (1) Story Building in Fair Condition • . - - il_ . • . • • .. _ • • . . - _ _ O . . - - - MIAMI - =DADE IAItiII -DADE COUNTY, FLORIDA MINIMUMtIN CTION PROCEDURAL GUIDELINES F BUILDING'S. STRUCTURAL RECERTIFICATIO INSPECTION COMMENCED DATE: 12 -22 -2008 INSPECTION COMPLETED DATE 12 -22-2008 DESCRIPTION OF STRUCTURE ifpi .JS eJC1C /c.l lLYI2_ 3 G24 BUILDING DEPART" ENT ,40u� .-c/o I ✓lL� go. 12/ 2 ail INSPECTION MADE BY SIGNATURE: Antonio R i va , P.E. PRINT NAME TITLE Atki ns Fngi neers ADDRESS: 228 At lantic Ro171 evard Suite 400, Key Largo, FL 33037 Marruss Corporation -A.R. Marsico 9165 Park Drive Miami Shores FL 33138 -3163 Marruss Corporation -A.R. Marsico 9165 Park Drive Miami Shores FL 33138 -3163 January 14, 2011 VEA E • • ••• • • • Mr. Ralph Martin 7439 Twin Sabal Drive Miami Lakes, Florida 33014 VE Alvarez at Partners, LLC Consulting Engineers Re: Estate of Albert Marsico, Jr. 40 -Year Electrical Recertification — Folio 11- 3206 - 014 -1350 9165 Park Drive - Miami Shores, Florida Attention: Mr. Ralph Martin Personal Representative/Executor INSPECTION REPORT Inspection Date: January 14, 2011 This inspection walk- through with Mr. Peter Koerber, President of Prestige Builders Corp and SAL Electric Contractors Corp. was performed at the request of Mr. Ralph Martin, Executor for the Estate of Albert Marsico, Jr., to review the work performed to make repairs as shown on the 40 -Year Electrical Recertification Report. During today's inspection, we found the following: 1. Items 1 through 4 of our December 21, 2010 report have been completed satisfactorily. 2. Item 5, UL listed and approved fire stopping has been completed, however, it must be inspected and approved by the Building Department's inspector. Please provide copies of approval by this inspector and document the UL listed method and materials used for this work. 3. The parking lot lighting foot candle level measurements cannot be performed until the trees are trimmed to the extent that they will not obstruct the path of the light to the surface of the parking lot. This is in accordance with Miami -Dade County Ordinance Chapter 8C -3. Please advise when this has been done to schedule the lighting level measurement. \`‘‘�``� ` � .\O E CO/ GENS • • . 'A • : No. 19881 • 13617 SW 118 Path — Miami, Florida 33186 -5248 CA # 27503 1.1 •• �. Phone: (305) 778 -9498 — Fax: (305) 238 -3511 — Email: valvarez@vealvarezandpartrte a. 'too0R • ►'' N� G`1�` MI.*- 4 ,0 u n ,tN Page 1 of 2 • / - /q_* • December 21, 2010 VEA E .•••••• 4.4•••••• ••••••• Mr. Ralph Martin 7439 Twin Sabal Drive Miami Lakes, Florida 33014 Attention: Mr. Ralph Martin Personal Representative/Executor Inspection Date: December 21, 2010 VE Alvarez & Partners, «C Consulting Engineers Re: Estate of Albert Marsico, Jr. 40 -Year Electrical Recertification — Folio 11- 3206 - 014 -1350 9165 Park Drive - Miami Shores, Florida INSPECTION REPORT This inspection walk - through with Mr. Peter Koerber, President of Prestige Builders Corp and SAL Electric Contractors Corp. was performed at the request of Mr. Ralph Martin, Executor for the Estate of Albert Marsico, Jr., to review the work performed to make repairs as shown on the 40 -Year Electrical Recertification Report. During the inspection, we found the following deficiencies that must be corrected: 1. The grounding electrode conductor is routed to the exterior of the building through a PVC conduit sleeve through the wall. The slope of the installed conduit will allow water to enter into the building and also to corrode the ground connections. Please correct this installation to prevent water entering the building or accumulating on ground connections. 2. There are 2 auxiliary gutters in the electrical room: A. One of the gutters is labeled as "LINE GUTTER ". This gutter contains the feeder for the North tenant space of the building. Please add a label with the following caption: "LINE GUTTER FOR NORTH TENANT SPACE OF 9165 PARK DRIVE — MAIN SERVICE DISCONNECT FOR THV NORTH TENANT SPACE IS MAIN 3 OF 3 AND IS LOCATEI��)� E. ,q �''�i THE EXTERIOR OF THE EAST WALL ". Place this new labe�i� y • • • • • ` ' ''•, � G E s •9 � below the existing "LINE GUTTER" label. C ,• e • No. t 9 : :N = /2 -2/1/® : STATE OF py 13617 SW 118 Path , Miami, Florida 33186 -5248 CA # 27503 %, °<e P ° �� ' ti '� 4 ` � Phone: (305) 778 -9498 - Fax: (305) 238 -3511 - Email: valvarez a@vealvarezandpartners o 0 ' ° • • • ° " G �;, ‘' ` lin 'moo Page 1 of 3 FEB PVEgwill Rkt 17 2011 December 21, 2010 VER ••••••• •••••••• Mr. Ralph Martin 7439 Twin Sabal Drive Miami Lakes, Florida 33014 VG Alvarez & Partners, «C Consulting Engineers Re: Estate of Albert Marsico, Jr. 40 -Year Electrical Recertification — Folio 11- 3206 - 014 -1350 9165 Park Drive - Miami Shores, Florida Attention: Mr. Ralph Martin Personal Representative/Executor B. The second gutter is labeled as "LOAD GUTTER" Please add a label with the following caption: "LOAD GUTTER FOR SOUTH TENANT SPACE OF 9165 PARK DRIVE — MAIN SERVICE DISCONNECTS FOR THE SOUTH TENANT SPACE ARE MAIN 1 OF 3 AND 2 OF 3 AND THEY ARE LOCATED IN THIS ROOM." Place this new label directly below the existing "LOAD GUTTER" label. 3. There are two circuit breakers in the electrical panel board in the north tenant space that have (2) conductors connected to their terminals. Only one conductor is permitted. These circuit breakers are supplying a Florida Power and Light energy saving device. Please contact Florida Power and Light and have one of the two conductors removed from each circuit breaker terminal. 4. Please add sign on exterior of meter room door with the caption shown on Paragraph2, sub -item 6 of the 40 -Year Electrical Recertification Report that reads as follows: "SERVICE DISCONNECTING MEANS FOR 9165 PARK DRIVE SOUTH TENANT SPACE LOCATED INSIDE THIS ELECTRIC ROOM ". 5. Provide UL listed and approved fire- stopping between the north and south tenant spaces inside the storage room located to the north of the electric room. Have fire - stopping inspected and approved by the Building Department. 6. All other items in the Report have been inspected and approved with the exception of the parking lot lighting and security lighting on exterior doors. Wow %I tiun,, , , ` % will perform a font- candle measurement one night within the next several .. NO E. Ai .�' „ i Please ensure that all of the lamps are on and operating at full brightnesAt."4 • .9 ', a repeat inspection for this reason. ... ....., S .-p -- ) 0 S l ? A% c b, . . .Z. Page 2 of 3 /41/16nigitiiiiitC:-‘‘‘‘‘‘ December 21, 2010 VEA Mr••••• • Mr. Ralph Martin 7439 Twin Sabal Drive Miami Lakes, Florida 33014 Attention: Mr. Ralph Martin Personal Representative/Executor VE Alvarez at Partners, PLC Consulting Engineers Re: Estate of Albert Marsico, Jr. 40 -Year Electrical Recertification — Folio 11- 3206 - 014 -1350 9165 Park Drive - Miami Shores, Florida 7. Advise when all of the above repairs or issues have been resolved so that we can perform a re- inspection. Please let us know if you have any questions or concerns. Sincerely, gi . Alvarez, PE�1,�� li , ��. Vir •° GE, S.. ° cOS Inspected by: ;Date: varei, x1981= Virg -o ; STATE OF \;191,, 111 ®• \\ \\ / 13617 SW 118 Path — Miami, Florida 33186 -5248 CA # 27503 Phone: (305) 778 -9498 — Fax: (305) 238 -3511 — Email: valvarez@vealvarezandparMersIlc.com Page 3 of 3 ,771 , To- MAR 0 7 2 r 11 9165 PARK DRIVE MIAMI SHORES, FLORIDA PREPARED BY: V.E. ALVAREZ & PARTNERS, LLC 13617 SW 118 PATH MIAMI, FLORIDA 33186 -5248 CA #27503 MARCH 3, 2011 B Y: VIRGILIO E. ALVAREZ, PE TEL (305) 778 -9498 PE #19881 FAX (305) 238 -3511 valvarez @vealvarezandpartnersllc.com 40 -YEAR ELECTRICAL RECERTIFICATION REPORT IAMI -DADE COUNTY, FLORIDA BUILDING DEPARTMENT MINIMUM INSPECTION PROCEDURAL GUIDELINF� iliit""1,,, FOR BUILDING ELECTRICAL RECERTIFICAT�G 00 E. INSPECTION COMMENCED INSPECTION MADE B � . , 1 1•,� /9881 Date: 12-09 -2008 SIGNATURE INSPECTION COMPLETED PRINT NAME: = `ii ilio v • N= Date: 12-09 -2008 TITLE: Coii 4Iiing BTjg t 9 . 54* ADDRESS: 1 $Q�,(I 1 . - • <, Miami, Fl i G..•G��1 %.` jfii /�r HA L'E ```0 1. DESCRIPTION O F STRUCTURE: a. NAME OF TITLE DR. ALBERTO MARSICO b. STREET ADDRESS 9165 PARK DR MIAMI SHORES FL 33138 -3163 c. LEGAL DESCRIPTION MIAMI SHORES SEC 2 PB 10-37 SWLY1 /2 LOT 24 & ALL LOTS 25 & 26 & NELY 1/2 LOT 27 BLK 59 LOT SIZE SITE VALUE d. OWNERS NAME MARRUSS CORP % A R MARSICO e. OWNER'S MAILING ADDRESS 9165 PARK DR MIAMI SHORES FL 33138 -3163 f. FOLIO NUMBER OF BUILDING: 11- 3206 - 014 -1350 g. BUILDING CODE OCCUPANCY CLASSIFICATION: PRO (PLANNED RESIDENTIAL OFFICE) h. PRESENT USE: 0013 OFFICE BUILDING i. GENERAL DESCRIPTION, TYPE OF CONSTRUCTION, SIZE, NUMBER OF STORIES, AND SPECIAL FEATURES. ADDITIONAL COMMENT. SINGLE STORY, CBS STRUCTURE USED FOR PROFESSIONAL OFFICES. V. E. Alvarez & Partners, LLC — CA #27503 Page 1 of 8 9165 Park Drive 13617 SW 118 Path, Miami, Florida 33186 Miami Shores, Florida 305- 778 -9498 veaengineer(iPcomcast.net 1. SIZE:4 /0 THW CU 3. CONDITION: GOOD VE Alvarez & Partners, UUC Consulting Engineers GUIDELINES AND INFORMATION FOR RECERTIFICATION OF ELECTRICAL SYSTEMS OF FORTY (40) YEAR STRUCTURES 1. ELECTRIC SERVICE: ELECTRIC SERVICE NO. 1 - 9165 SOUTH: 1. SIZE:500 MCM & 4/0 THW AL AMPERAGE (310/180) FUSES ( X ) BREAKER ( X 2. PHASE: (HI -LEG) THREE PHASE ( X ) SINGLE PHASE ( ) 3. CONDITION: GOOD ( ) FAIR ( ) NEED REPAIR ( X ) ELECTRIC SERVICE NO. 2- 9165 NORTH: 2. PHASE: THREE PHASE( X ) SINGLE PHASE ( AMPERAGE (200) FUSES ( X ) BREAKER ( FAIR NEED REPAIR ( X ) COMMENTS: ELECTRIC SERVICE NO. 1- 9165 SOUTH: 1) Seal the underground service raceway NEC 230.8 & 300.5(G) in CT enclosure. Photo #3. 2) Provide new ground bar inside CT enclosure to terminate all ground and bonding conductors inside, Photo #3. 3) Provide neutral bar inside CT enclosure to terminate all grounded conductors inside, Photo #3. 4) Identify each conductor in CT enclosure per NEC 110.14 and Article 200. Photo #3. ELECTRIC SERVICE NO. 2 - 9165 NORTH: 1) Provide an accessible Service Disconnecting Means for the 9165 Park Drive North Tenant Space. Photo # 5. ALL REPAIRS HAVE BEEN PERFORMED SATISFACTORILY AND APPROVED. 2. ELECTRIC ROOM: (LOCATED INSIDE 9165 SOUTH) PHOTO #4 1. CLEARANCES: GOOD (X) FAIR ( ) REQUIRES CORRECTION ( X ) 2. COMMENTS: 1) There is no Meter Room in this building. Both meters are located on the outside east wall. Photo #2 2) The existing Electric Room in 9165 SOUTH contains the disconnecting means for both 9165 SOUTH and 9165 NORTH tenant spaces. Photo #4. 3) Room has (2) doors. One leads outdoor and the second leads to the interior hallway of South Tenant space. Provide signs on both doors with the caption: "ELECTRIC ROOM - NO STORAGE" Photo #4 4) Remove all stored materials and equipment from this room. Replace ceiling tiles as required. Patch all walls as needed. Photo #4 5) Provide permanent and durable identification on each existing electric meter on the exterior walls: "9165 PARK DR. - SOUTH TENANT SPACE" and "9165 PARK DR. - NORTH TENANT SPACE" 6) Provide sign on the exterior door of the Electric Room with the followirkst Wig • 4 ", "SERVICE DISCONNECTING MEANS FOR 9165 PARK DR. SOUTH TEISIW . • G•9'''• , � LOCATED INSIDE THIS ELECTRIC ROOM" • . „. ALL REPAIRS HAVE BEEN PERFORMED SATISFACTORILY AND APPAOVVD. N =- V. E. Alvarez & Partners, LLC - CA #27503 Page 2 of 8 9165 Parkvg 3 _ 3- /I * ; 13617 SW 118 Path, Miami, Florida 33186 Miami Shtesj 305- 778 -9498 veaengineer(a),comcast.net ` \0111111111/• OF ELECTRICAL SYSTEMS OF FORTY (40) YEAR STRUCTURES 3. GUTTERS: 1. LOCATION: In Electric Room (See Comments) 2. TAPS AND FILL In Electric Room (See Comments) 3. COMMENTS: 4. ELECTRICAL PANELS: 9165 PARK DRIVE — SOUTH TENANT SPACE 1. PANEL # (S ): 2. COMMENTS: GOOD ( 2. COMMENTS: NEEDS REPAIR ( X ) GUIDELINES AND INFORMATION FOR RECERTIFICATION V. E. Alvarez & Partners, LLC - CA #27503 13617 SW 118 Path, Miami, Florida 33186 305- 778 -9498 veaengineerici comcast.net rOVIC " GOOD ( ) REQUIRES REPAIR (X ) GOOD ( ) REQUIRES REPAIR (X) 1) Identify each line gutter in the Electric Room with a sign stating (Photo #6): "LINE GUTTER -9165 PARK DR. SOUTH TENANT SPACE" and "LINE GUTTER -9165 PARK DR. NORTH TENANT SPACE" 2) Provide bonding as required per NEC Article 250. Photo # 6. 3) Verify that taps and fill are in good condition. Replace if necessary. Photo # 6. ALL REPAIRS HAVE BEEN PERFORMED SATISFACTORILY AND APPROVED. LOCATION: IN ELECTRIC ROOM IN SOUTH TENANT SPACE. PHOTO # 7 GOOD ( ) NEEDS REPAIR (X ) PHOTO #8: 1) REMOVE FEEDER CONDUCTORS FROM LUGS. 2) CLEAN LUGS AND REMOVE ALL DIRT, DEBRIS AND ABANDONED CONDUCTORS. 3) CLEAN AND WIRE BRUSH CONDUCTOR ENDS AND APPLY AN OXIDE INHIBITOR TO THE BARE CONDUCTOR PRIOR TO REINSTALLATION. 4) INSTALL KNOCK OUT PLUGS AS REQUIRED ON ALL PANEL WALLS. PHOTO #9: 1) IDENTIFY FEEDER NEUTRAL PER NEC 110.14 Article 200. 2) INSPECT AND REPAIR OR REPLACE ANY NEUTRAL WITH CHARRED OR OVERHEATED NEUTRAL CONDUCTORS IN THE NEUTRAL BAR. 3) REMOVE ABANDONED CONDUCTOR PIECES LEFT IN NEUTRAL BAR TERMINALS. PHOTO #10: 1) INSPECT AND REPLACE ALL CIRCUIT BREAKERS WITH CORRODED TERMINALS AND RE- TERMINATE BRANCH CIRCUIT CONDUCTORS IN NEW BRANCH CIRCUITS, TYPICAL. 2) IDENTIFY SOURCE OF MOISTURE OR WATER INTRUSION, IF ANY, AND MAKE REPAIRS TO PREVENT FUTURE DAMAGE. ALL REPAIRS HAVE BEEN PERFORMED SATISFACTORILY AND APPROVED. 9165 PARK DRIVE — NORTH TENANT SPACE 1. PANEL # ( N ): LOCATION: IN LOUNGE/KITCHEN AREA. SEE PHOTO #11 1) THERE ARE (2) BRANCH CIRCUIT BREAKERS WITH (2) CONDUC PER TERMINAL. REMOVE EXTRA BRANCH CONDUCTOR AND T IN SPARE BRANCH CIRCUIT BREAKER OF THE CORRESPON! Q rT)I ALL REPAIRS HAVE BEEN PERFORMED SATISFACTORILY AN Page 3 of 8 II I / / ,, f s • No. 19881 9165 Park Dti ; 3 '3` // * • Miami Sh o y �t�ida STAT OF .OR Ot.c,644i 11 1,II 11111��� Wal luitbilm72 a Paa Parsars uc GUIDELINES AND INFORMATION FOR RECERTIFICATION OF ELECTRICAL SYSTEMS OF FORTY (40) YEAR STRUCTURES 5. BRANCH CIRCUITS: 9165 PARK DRIVE - SOUTH TENANT SPACE - PANEL S 1. IDENTIFIED: YES ( ) MUST BE IDENTIFIED ( X ) 2. CONDUCTORS: GOOD ( X ) DETERIORATED ( ) MUST BE REPLACED ( ) 3. COMMENTS: PHOTO #12: IDENTIFY ALL BRANCH CIRCUITS IN PANEL DIRECTORY. ALL REPAIRS HAVE BEEN PERFORMED SATISFACTORILY AND APPROVED. 9165 PARK DRIVE - NORTH TENANT SPACE - PANEL N 1. IDENTIFIED: YES ( X ) MUST BE IDENTIFIED ( ) 2. CONDUCTORS: GOOD ( X ) DETERIORATED ( ) MUST BE REPLACED ( ) 3. COMMENTS: NONE 6. GROUNDING OF SERVICE: 9165 PARK DRIVE — SOUTH TENANT SPACE CONDITION: GOOD ( ) REPAIRS REQUIRED ( X ) COMMENTS: EXISTING GROUNDING SYSTEM IS NOT TO CODE. INSTALL NEW GROUNDING SYSTEM, INCLUDING NEW LISTED TERMINALS IN CT ENCLOSURE. PHOTO # 13. ALL REPAIRS HAVE BEEN PERFORMED SATISFACTORILY AND APPROVED. 9165 PARK DRIVE - NORTH TENANT SPACE CONDITION: GOOD ( ) REPAIRS REQUIRED ( X ) COMMENTS: 1) CLEAN -UP PAINT AND RUST FROM GROUND RODS, HOSE BIB, GROUND CLAMPS AND CONDUCTORS IN EXISTING ELECTRIC SERVICE GROUNDING SYSTEM. PHOTOS # 14 & 15. ALL REPAIRS HAVE BEEN PERFORMED SATISFACTORILY AND APPROVED. 7. GROUNDING OF EQUIPMENT: 9165 PARK DRIVE — SOUTH TENANT SPACE CONDITION: GOOD ( ) REPAIRS REQUIRED ( X ) 9165 PARK DRIVE — NORTH TENANT SPACE CONDITION: GOOD ( ) REPAIRS REQUIRED ( X ) COMMENTS: 1) SOUTH TENANT SPACE: PHOTOS # 16 & 17 - PROVIDE GROUNDINROMIHINO, IN CT ENCLOSURE, LINE GUTTER, PANEL AND MAINS. BOND PER NEC TABLE *11 el b. i '1',, 2) NORTH TENANT SPACE: PHOTO # 18 - PROVIDE GROUNDING BUSHINGS 11�� •. ',.., AND PANELS AND MAINS. BOND PER NEC TABLE 250.122. ��'� - N, , `��t` - ' � ALL REPAIRS HAVE BEEN PERFORMED SATISFACTORILY AND APPROVED, �a N0. 19881 " V. E. Alvarez & Partners, LLC — CA #27503 Page 4 of 8 9165 - 13617 SW 118 Path, Miami, Florida 33186 Miami Shog daSTATE e P o 305- 778 -9498 veaen ineer(c4comcast.net .. s • ' ORIO• :AN.- • G �� � .; ONAL E N " III 1%%t�� ``� 8. SERVICE CONDUITS RACEWAYS: CONDITION: COMMENTS: CONDITION: ve Alvarez & Partners, LLC consulting Engineers GUIDELINES AND INFORMATION FOR RECERTIFICATION OF ELECTRICAL SYSTEMS OF FORTY (40) YEAR STRUCTURES 9165 PARK DRIVE — SOUTH TENANT SPACE CONDITION: GOOD ( X ) REPAIRS REQUIRED ( ) 9165 PARK DRIVE — NORTH TENANT SPACE CONDITION: GOOD ( X ) REPAIRS REQUIRED ( ) COMMENTS: 9. SERVICE CONDUCTOR AND CABLES: 9165 PARK DRIVE — SOUTH TENANT SPACE CONDITION: GOOD ( X ) REPAIRS REQUIRED ( ) 9165 PARK DRIVE — NORTH TENANT SPACE GOOD ( X ) REPAIRS REQUIRED 10. TYPES OF WIRING METHODS: 9165 PARK DRIVE — SOUTH TENANT SPACE CONDITION: CONDUIT RACEWAYS: GOOD ( ) REPAIRS REQUIRED ( X ) PHOTOS 19, 20, 21 CONDUIT PVC: GOOD ( ) REPAIRS REQUIRED ( ) NM CABLE: N/A GOOD ( ) REPAIRS REQUIRED ( ) BX CABLE: N/A GOOD ( ) REPAIRS REQUIRED ( ) ALL REPAIRS HAVE BEEN PERFORMED SATISFACTORILY AND APPROVED. 9165 PARK DRIVE — NORTH TENANT SPACE CONDUIT RACEWAYS: GOOD ( ) REPAIRS REQUIRED ( X ) PHOTOS 22, 23 CONDUIT PVC: GOOD ( ) REPAIRS REQUIRED ( ) 0011111tttiii,i 0 \0 E. 4 � '', NM CABLE: N/A GOOD ( ) REPAIRS REQUIRED ( ) �` C.1` . • E • ` `,' Q- • �c N • ,p BX CABLE: N/A GOOD ( ) REPAIRS REQUIRED ( ) , • N0 1 • ALL REPAIRS HAVE BEEN PERFORMED SATISFACTORILY AND APPROVED. = * m — * 3.3,, * _ -0. TATEOF V. E. Alvarez & Partners, LLC — CA #27503 Page 5 of 8 9165 Park I7 • t 13617 SW 118 Path, Miami, Florida 33186 Miami Shore da` O R 10 P � � ���� 305- 778 -9498 veaengineerr;comcast.net `'' "ONAL EtyGo`\ tit ttittl° CONDITION: CONDUIT RACEWAYS: CONDUIT PVC: NM CABLE: BX CABLE: 12. EMERGENCY LIGHTING: 9165 PARK DRIVE — SOUTH TENANT SPACE CONDITION: COMMENTS: ALL REPAIRS VGA V. E. Alvarez & Partners, LLC — CA #27503 13617 SW 118 Path, Miami, Florida 33186 305- 778 -9498 veaengineer@comcast.net VE Alvarez & Partners, U.0 Consulting Engineers IE. GUIDELINES AND INFORMATION FOR RECERTIFICATION OF ELECTRICAL SYSTEMS OF FORTY (40) YEAR STRUCTURES 11. FEEDER CONDUCTORS: 9165 PARK DRIVE — SOUTH TENANT SPACE CONDITION: CONDUIT RACEWAYS: GOOD ( ) REPAIRS REQUIRED ( X ) CONDUIT PVC: GOOD ( ) REPAIRS REQUIRED ( ) NM CABLE: GOOD ( ) REPAIRS REQUIRED ( ) BX CABLE: GOOD ( ) REPAIRS REQUIRED ( ) ALL REPAIRS HAVE BEEN PERFORMED SATISFACTORILY AND APPROVED. 9165 PARK DRIVE — NORTH TENANT SPACE GOOD ( X) REPAIRS REQUIRED ( ) GOOD ( ) REPAIRS REQUIRED ( Page 6 of 8 GOOD ( ) REPAIRS REQUIRED ( ) GOOD ( ) REPAIRS REQUIRED ( ) COMMENTS: 1) FEEDER CONDUCTOR BEHIND BRANCH CIRCUIT CONDUCTORS IN PANEL S APPEARS TO BE CHARRED. CHECK CONDITION OF CONDUCTOR AND REPAIR OR REPLACE AS REQUIRED. PHOTO #10. ALL REPAIRS HAVE BEEN PERFORMED SATISFACTORILY AND APPROVED. CONDITION: GOOD ( ) REPAIRS REQUIRED ( X ) COMMENTS: 1) PROVIDE ADDITIONAL EMERGENCY LIGHTING IN MAIN HALL WAY AND WHERE EXIT DOORS ARE LOCATED. PHOTOS # 24, #25, TYPICAL. ALL REPAIRS HAVE BEEN PERFORMED SATISFACTORILY AND APPROVED. 9165 PARK DRIVE — NORTH TENANT SPACE GOOD ( ) REPAIRS REQUIRED ( X ) RELOCATE EMERGENCY LIGHT FROM ABOVE BOOKCASE. PHOTch#i8 6iiii, HAVE BEEN PERFORMED SATISFACTORILY AND APPROVED q � ,� '1i, •CEN, �% 9 ". S OF : 9165 Path i a O R I O P• k,�'� Miami Shdr� � , ° E�yG���.`� ,,,iie iii n ►i���\ CONDITION: COMMENTS: 14. FIRE ALARM SYSTEM: N/A 16. EXIT LIGHTS: CONDITION: COMMENTS: 17. EMERGENCY GENERATOR: 9165 PARK DRIVE - NORTH TENANT SPACE 9165 PARK DRIVE - SOUTH TENANT SPACE 9165 PARK DRIVE - NORTH TENANT SPACE VE Alvarez & Partners, LLC Consulting Engineers GUIDELINES AND INFORMATION FOR RECERTIFICATION OF ELECTRICAL SYSTEMS OF FORTY (40) YEAR STRUCTURES 13. BLDG. EGRESS ILLUMINATION: 9165 PARK DRIVE - SOUTH TENANT SPACE CONDITION: GOOD ( ) REPAIRS REQUIRED ( X ) COMMENTS: REPLACE ALL LAMPS IN EXISTING MEANS OF EGRESS ILLUMINATION. PHOTO #24. REPLACE LAMPS AND INSTALL LENS ON MEANS OF EGRESS LIGHTING FIXTURE. PHOTO #27. ALL REPAIRS HAVE BEEN PERFORMED SATISFACTORILY AND APPROVED. GOOD ( X ) REPAIRS REQUIRED ( CONDITION: GOOD ( ) REPAIRS REQUIRED ( ) COMMENTS: THERE IS NO FIRE ALARM SYSTEM IN THIS BUILDING. 15. SMOKE DETECTORS: N/A CONDITION: GOOD ( ) REPAIRS REQUIRED ( ) COMMENTS: THERE ARE NO SMOKE DETECTORS IN THIS BUILDING. CONDITION: GOOD ( ) REPAIRS REQUIRED ( X ) COMMENTS: 1) INSTALL NEW EXIT LIGHT. PHOTO #27 2) REPLACE BURNED OUT LAMPS IN EXIT LIGHT THROUGHOUT AS REQUIRED. Photo #28. ALL REPAIRS HAVE BEEN PERFORMED SATISFACTORILY AND APPROVED. GOOD ( X ) REPAIRS REQUIRED ( ) 01111IIII /U ' 4 H OC E NSF • . 4) CONDITION: GOOD ( ) REPAIRS REQUIRED ( ) • COMMENTS: THERE IS NO EMERGENCY GENERATOR IN THIS BUILDING. !:*!oif:.a - /I F . � STAT o • • V. E. Alvarez & Partners, LLC - CA #27503 Page 7 of 8 9165 Park ;, , ° 1 � : O R I O • ° <t, ��`� 13617 SW 118 Path, Miami, Florida 33186 Miami Shore* cE'ida ° ° ° _s�`� 305 778 - 9498 veaengineer@comcast.net 20. SWIMMING POOL WIRING: VGA GUIDELINES AND INFORMATION FOR RECERTIFICATION OF ELECTRICAL SYSTEMS OF FORTY (40) YEAR STRUCTURES 18. WIRING IN OPEN OR UNDER COVER PARKING GARAGE AREAS: N/A CONDITION: GOOD ( ) REPAIRS REQUIRED ( ) COMMENTS: THERE IS NO OPEN OR UNDER COVER PARKING FOR THIS BUILDING. 19. OPEN OR UNDERCOVER PARKING SURFACE AND SECURITY LIGHTING CONDITION: GOOD ( ) ILLUMINATION REQUIRED ( X ) COMMENTS: Per Metropolitan Dade County Code Chapter 8C, this property requires "Open parking Tots and access thereto..." illumination. In addition, "...the areas immediately outside of exterior doors shall have security illumination and shall be activated during the dark period of every day." PHOTO # 29. A NEW LIGHTING SYSTEM COMPLYING WITH CHAPTER 8C HAS BEEN INSTALLED. CONDITION: GOOD ( ) REPAIRS REQUIRED ( ) COMMENTS: THERE IS NO SWIMMING POOL IN THIS BUILDING. 21. WIRING TO MECHANICAL EQUIPMENT: 9165 PARK DRIVE — SOUTH TENANT SPACE CONDITION: UNKNOWN GOOD ( ) REPAIRS REQUIRED ( ) 9165 PARK DRIVE — NORTH TENANT SPACE CONDITION: UNKNOWN GOOD ( ) REPAIRS REQUIRED ( ) COMMENTS: THE MECHANICAL EQUIPMENT ON THE ROOF WAS NOT ACCESSIBLE AND COULD NOT BE INSPECTED. IT IS RECOMMENDED THAT ARRANGEMENTS BE MADE TO ACCESS THE ROOF TO INSPECT THIS EQUIPMENT. ALL REPAIRS HAVE BEEN PERFORMED SATISFACTORILY AND APPROVED. 22. GENERAL ADDITIONAL COMMENTS: 9165 PARK DRIVE — SOUTH TENANT SPACE: 1) REPLACE ALL CRACKED, MISSING DEVICE COVERS THROUGH OUT BUILDING. PHOTOS # 30, #31. 2) REPLACE ALL MISSING OR BROKEN FIXTURE LENSES AS REQUIRED. PHOTO # 32.3) REMOVE EXTENSION CORDS BEING USED AS PERMANENT WIRING OR REPLACE WITH APPROVED WIRING METHODS. PHOTO # 33, TYPICAL. 4) REPLACE EXISTING RECEPTACLES IN TREATMENT AREAS WITH GFCI PROTECTED RECEPTACLES. PHOTO #34, TYPICAL. ALL REPAIRS HAVE BEEN PERFORMED SATISFACTORILY AND APPROVED. V. E. Alvarez & Partners, LLC — CA #27503 13617 SW 118 Path, Miami, Florida 33186 305 778 - 9498 veaengineer@comcast.net VE Alvarez & Partners, LLC Consulting Engineers Page 8 of 8 $ E A �' • = -Q • ST 3 F J' ��� Pai ° ve �. Miam 9165 Shiest lo1c R Q ° •� . � l ® EN C:``�� VER M ID O• e • • • • January 31, 2011 VE Alvarez & Partners, Engineers 6ls. LLC ers, «C Consulting Engineers Miami -Dade Building Department 11805 SW 26 Street (Coral Way) Miami, FL 33175 -2474 Re: Open Parking Lot Lighting 9165 Park Drive Miami Shores, Florida To whom it may concern: On the night of Saturday, January 29, 2011, the foot candle levels on the parking lot surfaces were measured for compliance with Section 8C -3 of the Code of Miami -Dade County. The measured levels meet the minimum requirements of 1.0 foot candle average and a maximum foot candle to minimum foot candle not to exceed a ratio of 12:1 foot candles. For this reason, I certify that the parking lot lighting at the above property address meets the illumination levels required by Miami -Dade County. • A GE NS F • .'Q� • V t% - : , * e irgS fE'ar •Flo da PE #98a, ,� FS OR io . •G��► ` �,`` ' './,,5 /ONA1. **C/ 0 13617 SW 118 Path • Miami, FL 33186 Phone: (305) 778 -9498 • Fax: (305) 238 -3511 • Email: veaengineer@comcast.net Mr. Ralph Martin Personal Representative Estate of Albert Marsico 7439 Twin Sabal Drive Miami Lakes, FL 33014 Dear Mr. Martin Applied Fire proofing Foam ATKINS ENGINEERS, INC. 228 ATLANTIC BOULEVARD, SUITE 400 KEY LARGO, FLORIDA 33037 KEYS 305.451.4556 305.451.4557 FAX MIAMI 305.444.6260 305.442.2201 FAX CA # 6964 AR # AA26001691 February 10, 2011 Re: 40 year recertification, Marsico Bldg Miami Shores As per your request, I visited Marsico Building, 9165 Park Dr. Miami Shores, FL 33138 to observe and report on the addition of fire proofing material as required by the Building Department prior to issue a 40 year recertification for the building. Hilti Fireproofing Foam Page 2 of 2 In my professional opinion, the fire proofing foam was applied as required and therefore I recommend recertifying the building. It is my understanding that this was the only pending issue. Yours truly, X 011 111 111/0, S ENGINEERS, I� ® 4®� ® ®c //, 1 • No 61086 ; * ... o J Riva • STATE OF ' • • ' '' e P.E. # 61565 a -��ot� 1 OP' ` � 2/10/2011 lillfil O Miami Shores Building Department 10050 Northeast 2nd Avenue Miami Shores, Florida 33139 ATKINS ENGINEERS, INC. 228 ATLANTIC BOULEVARD, SUITE 400 KEY LARGO, FLORIDA 33037 KEYS 305.451.4556 305.451.4557 FAX MIAMI 305.444.6260 305.442.2201 FAX CA # 6964 AR # AA26001691 February 25, 2011 RE: 40 Year Building Safety Inspection Report - Structural Marruss Corporation A. R. Marsico 9165 Park Drive, Miami Shores, FL 33138 -3163 Atkins Engineers has performed a visual structural observation of the building referenced above. The building is one -story structure with masonry walls at exterior sides supporting pre -cast Double Tee Roof System and conventional built -Up Roofing. The floor is a concrete slab on grade. Based on our observations, the building appears to be in fair conditions. We are enclosing three copies of the Minimum Inspection Procedural Guidelines for Building's Structural Recertification and Photographs on the above mentioned property. The comments and statements herein are to the best of my knowledge and refer to the existing condition of the building structure based on the observations we could perform and accessibility to the different locations of the building. If you should have any questions, please do not hesitate to contact us. Enclosures. Yours truly, e0", 1 . 4: : c j E E N : (/ . ,. . . * Na 6159 :7 * — 1 1 *= se dipt;TG ' Antonio Riva, PE. 2/z 5/// STATE OF I , • J , / 1 1J 1 MIAMI DADE COUNTY MINIMUM INSPECTION PROCEDURAL GUIDELINES FOR BUILDING STRUCTURAL RECERTIFICATION COMMENCED Date: 12 -22 -2008 INSPECTION COMPLETED Date: 12 -22 -2008 1. DESCRIPTION OF STRUCTURE I a. Name on Title: Marruss Corp - A. R. Marsico . Legal Description: Miami Shores Section 2 PB 10 -37 d. Owner's Name: A. R. Marsico . Building Code Occupancy Classification: Business Group B INSPECTION MADE BY: Antonio Riva SIGNATURE: PRINT NAME: Antonio Riva, P.E. TITLE: Engineer ADDRESS: 228 Atlantic Boulevard Suite 400 Key Largo FL 33037 h. Present Use: Professional Office Building i. General Description, Type of Construction, Size, Number of Stories, and Special Features Additional Comments: One (1) Story Building in Fair Condition. Concrete masonry block walls support precast Double Tee Roof System and conventional flat Built -up Roofing. b. Street Address: 9165 Park Drive, Miami Shores, FL 33138 -3163 e. Owner's Mailing Address: 9165 Park Drive, Miami Shores, FL 33138 . Folio Number of Property on which Building is Located: 11- 3206 - 014 -1350 BUILDING & NEIGHBORHOOD COMPLIANCE DEPARTMENT Additions to original structure: 2 PRESENT CONDITION OF STRUCTURE a. General alignment (not good, fair, poor, explain if significant) None 1. Bulging Fair 2. Settlement Fair 3. Defections Fair 4. Expansion Fair 5. Contraction Fair b. Portion showing distress (Note, beams, columns, structural walls, floors, roofs, other) Fair condition c. Surface conditions — describe general conditions of finishes, noting cracking, spalling, peeling, signs of moisture penetration & stains. a. Date of notice of required inspection 2008 b. Date(s) of actual inspection 12 -22 -2008 c. Name and qualifications of individual submitting inspection report: Antonio Riva, P.E. d. Description of any laboratory or other formal testing, if required, rather than manual or visual procedures None e. Structural repair -note appropriate line: 1. None required X 2. Required (describe and indicate acceptance) d. Cracks — note location in significant members. Identify crack size as HAIRLINE if barely discernible; FINE if less than 1 mm in width: MEDIUM if between 1 and 2 mm in width; WIDE if over 2 mm. None e. General extent of deterioration — cracking or spalling of concrete or masonry; oxidation of metals; rot or borer attack in ood. None f. Previous patching or repairs None g. Nature of present loading indicate residential, commercial, other estimate magnitude. Commercial 3. INSPECTIONS 4. SUPPORTING DATA sheet written data photographs c. drawings or sketches: a. b. X . Concrete masonry units Fair . Clay tile or terra cota units c. Reinforced concrete tie columns Fair d. Reinforced concrete tie beams Fair e. Lintel . Other type bond beams • . Masonry finishes - exterior 1. Stucco Fair 2. Veneer 3. Paint only 4. Other(describe) Decorative stone panels - Fair h. Masonry finishes - interior 1. Vapor barrier 2. Purring and plaster 3. Paneling Fair 4. Paint only 5. Other (describe) I. Cracks: None 1. Location - note beams, columns, other 2. Description '. Spalling: None 1. Location - note beams, columns, other 2. Description k. Rebar corrosion -check appropriate line: 1. None visible X 2. Minor - patching will suffice 3. Significant -but patching will suffice 4. Significant - structural repairs required 5. MASONRY BEARING WALL Indicate good, fair, poor on appropriate lines: I. Samples chipped out for examination in spall areas: 1. No. X 2. Yes - describe color, texture, aggregate, general quality 6. FLOOR AND ROOF SYSTEM k R 00 t Flat Roof 1. Describe (flat, slope, type roofing, type roof deck, condition. Flat - Precast Double Tee Roof System 2. Note water tanks, cooling towers, air conditioning equipment, signs, other heavy equipment and condition of support: Air Conditioning equipment supports in fair condition 3. Note types of drains and scuppers and condition: Overflow scuppers with exposed downspouts b. Floor system(s) Slab on grade - unexposed 1. Describe (type of system framing, material, spans, condition) Concrete slab on grade c. Inspection — note exposed areas available for inspection, and where it was found necessary to open ceilings, etc. for inspection of typical framing members. None 7. STEEL FRAMING SYSTEM b. Exposed Steel - describe condition of paint & degree of corrosion: N/A c. Concrete or other fireproofing — note cracking or spalling, and note where any covering was removed for inspection N/A d.Elevator sheave beams & connections, and machine floor beams — note condition: N/A 8. CONCRETE FRAMING SYSTEM a. Full description of structural system N/A b. Cracking 1. Not significant 2. Location and description of members affected and type cracking N/A c. General condition N/A d. Rebar corrosion - check appropriate line: 1. None visible N/A 2. Location and description of members affected and type cracking N/A 3. Significant but patching will suffice N/A 4. Significant - structural repairs required (describe) N/A e. Samples chipped out in spall areas: N/A 1. No. 2. Yes, describe color, texture, aggregate, general quality: a. Type (Wood, steel, aluminum, jalousie, single hung, double hung, casement, awning, pivoted, fixed, other) Alum. b. Anchorage — type & condition of fasteners and latches: Covered c. Sealant — type of condition of perimeter sealant & at mullions: Fair d. Interiors seals — type & condition at operable vents: Fair e. General condition: Fair a. Type — fully describe if mill construction, light construction, major spans, trusses; N/A b. Note metal fitting i.e., angles, plates, bolts, split pintles, pintles, other, and note condition: N/A c. Joints — note if well fitted and still closed: N/A d. Drainage — note accumulations of moisture: N/A e. Ventilation —note any concealed spaces not ventilated: N/A f. Note any concealed spaces opened for inspection: N/A 9: WINDOWS 10. WOOD FRAMING SD:rs:vc:mb:js: rtc1:2/11 /2010:40yrtrackingsystem Building's Sructural Re- certification 9165 Park Drive Miami Shores FL 33138 Building's Sructural Re- certification 9165 Park Drive Miami Shores FL 33138 Building's Sructural Re- certification 9165 Park Drive Miami Shores FL 33138 Building's Sructural Re- certification 9165 Park Drive Miami Shores FL 33138 Building's Sructural Re- certification 9165 Park Drive Miami Shores FL 33138 Building's Sructural Re- certification 9165 Park Drive Miami Shores FL 33138 6