CC-08-220
{ l@ Inspection Worksheet Ie Miami Shores Village r3 10050 N.E. 2nd Avenue Miami Shores, FL �R Ki0 A. ;$ Phone: (305)795 -2204 Fax: (305)756 -8972 I ii • • .:...: • :• .::::.. ...... . • •.::.:.;:.::.::.::.::.::.:::.::.::;::::.;:..::.::.::.::.::.::.:::.;:.;:.;:.;;:<:.:;:. �:::<:.;:.;:::.::.::::.::.:::<:::.;::::. :::.::.::::::::: >•::::<::::.::. ...:..: . Inspection Date: 04109/2008 Permit Type: Commercial Construction Inspector: Grande, Claudio Inspection Type: Final Owner: EMMERT, LENT �l � s�. Work Classification: New Job Address: 9833 MIAMI Avenue N Miami Shores, FL 33138- Phone Number Parcel Number 1132060131090 Project: <NONE> Block: Lot: Contractor: IVY H SMITH COMPANY Phone: (305)257 -0222 Buildina De artment Comments AT &T IS PLACING A NEW CABINET AT SIDE OF9833 N MIAMI AVE FOR FUTURE SERVICE. SEE ATTACHED SKETCH FOR DETAILS. Inspector Comments Pass cc Failed El Correction Needed Re- Inspection Fee ($75) No Additional Inspections can be scheduled until re- inspection fee is paid . Wednesday, April 9, 2008 Page 1 of 2 y y Inspection Worksheet Miami Shores Village i %ta js • � ' 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 s }� i..•.•. bt Inspection Date: 03/21/2008 Permit Type: Electrical - Commercial Inspector: Devaney, Michael Inspection Type Final Owner: EMMERT, OSCAR Work Classification Addition /Alteration Job Address: 9833 MIAMI Avenue N Miami Shores, FL 33138- Phone Number Parcel Number 1132060131090 Project: <NONE> Block: Lot: Contractor: MESA ELECTRIC SYSTEMS CORP Phone: 305 - 279 -5498 Building Department Comments AT &T IS PLACING A NEW CABINET AT SIDE OF9833 N MIAMI AVE FOR FUTURE SERVICE SEE ATTACHED SKETCH. ELECTRICAL WORK FOR NEW CABINET. �pR Inspector Comments Passed Z_ Failed Failed Correction Needed Re- Inspection Fee ($75) No Additional Inspections can be scheduled until re- Inspection fee is paid . Thursday, March 20, 2008 Page 2 of 2 i 1 _ Miami Shores Village y ry 10050 N.E. 2nd Avenue Miami Shores, FL 33138 -0000 Phone: (305)795 -2204 Expiration: 0812312 Project Address Parcel Number Applicant 9833 N MIAMI Avenue 1132060131080 LENT EMMERT Miami Shores, FL 33138- Block: Lot: Owner Information Address Phone cell LENT EMMERT 9833 N MIAMI Avenue MIAMI SHORES FL 33150 -1746 Contractor(s) Phone Cell Phone Valuation: $ 5,000 IVY H SMITH COMPANY _.:::�,� �_„_:.... .�- :_— _.....,k..._- ::::__::..� .:::::::__::__:::.� ._::::__::____. �_ a... �.__ rc .... ........ ..................... ....._� ..:::::... ................._._...._..._ .::_::::_ _::__. ...........__.......... ., Total Sq Feet p Approved: Yes Available Inspections: Comments: Inspection Type: Date Approved: 2/1512008: Yes Tie Beam Bond Bea Date Denied: Wire Lame Type of Construction: Occupancy Load: Floor Trusses Stories: Exterior. Termite Letter Front Setback: Rear Setback: Shutter Final Left Setback: Right Setback: Roof Trusses Plans Submitted: Certification Status: Drywall screw Stem Wall Footer Certification Date: Additional Info: Insulation Bond Return: Classification: Commercial Wi ndow Door Attachment Trusses Plan Submittal Final Building Fees Due Amount Total Amt Paid Amt Due Framing Total: $ 0.00 $ 0.00 $ 0.00 Rake Beam Second Floor Tie Bond Beam Payment Type: Density Fill Cells Columns Final PE Certificadon Wall Sheathing Window and Door Buck Roar Sheathing Spot Survey Footer Column Pads Slab Seoond Floor Slab NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the County Copy public records of this county. AND THERE MAY BE ADDITIONAL PERMITS REQUIRED FROM OTHER GOVERNMENTAL ENTITIES SUCH AS WATER MANAGEMENT DISTRICTS, STATE AGENCIES, OR FEDERAL AGENCIES. Monday, February 25, 2008 3 t M AO , ✓v } ;' F W IN? Miami Shores Village 10050 N.E. 2nd Avenue hr' F Miami Shores, FL 33138 -0000 Phone: (305)795 -2204 y� r_xPIra ion 08 1231 2008 Project Address Parcel Number Applicant 9833 N MIAMI Avenue 1132060131090 Miami Shores, FL 33138 Block: Lot: LENI EMMERT Owner information Address Phone Cell LEN[ EMMERT 9833 N MIAMI Avenue MIAMI SHORES FL 33150 -1746 Contractor(s) Phone Cell Phone Valuation: $ 5, 000.00 IVY H SMITH COMPANY Total Sq Feed 0 Approved: Yes Available Inspections: Comments: Inspection Typ Date Approved: 2/15 /2008: Yes re Beam Band B eam Date Denied: Wre Lathe Type of Construction: Occupancy Load: Floor Trusses Stories: Exterior: Termite Letter Front Setback: Rear Setback: Shutter Final Left Setback: Right Setback: Ro&Trusses Plans Submitted: Certification Status: Drywall screw Stem Wail Footer Certification Date: Additional Info: Insulation Bond Return: Classification: Commercial WiindowDoor Attachment Trusses Plan Submittal Final Building Fees Due Amount Total Amt Paid Amt Due Framing Total: $ 0.00 $ 0.00 $ 0.00 Rake Beam Second Floor Tie Bond Beem Payment Type: Density Fill Cells Columns Final PE Certification Wall Sheathing Window and Door Buck Roof Sheathing Spot Survey Footer Column Pads Slab Second Floor Slab NOTICE: In addition to the requirements of this permit, there may be Finance Co additional restrictions applicable to this property that may be found in the Cop public records of this county. AND THERE MAY BE ADDITIONAL PERMITS REQUIRED FROM OTHER GOVERNMENTAL ENTITIES SUCH AS WATER MANAGEMENT DISTRICTS, STATE AGENCIES, OR FEDERAL AGENCIES. Monday, February 25, 2008 4 ys Miami Shores Village - ry Gstr�n 10050 N.E. 2nd Avenue �Y c h { Miami Shores, FL 33138 -0000 Phone: (305)795 -2204 Expiration: 08/231200 Project Address Parcel Number Applicant 9833 N MIAMI Avenue 1132060131090 LENT EMMERT Miami Shores, FL 33138- Block: Lot Owner Information Address Phone Cell LENI EMMERT 9833 N MIAMI Avenue MIAMI SHORES FL 33150 -1746 Contractor(s) Phone Cell Phone Valuation: $ 5,000 IVY H SMITH COMPANY ___.:� _...... r._ w.:.: t- ..._.__... _ _._._. ...._....... Total Sq Feet 0 Approved: Yes Availablelnspections: Comments: Inspection Type: YPe: Date Approved: 2/15 /2008: Yes re Beam Bond Bea Date Denied: Wre Type of Construction: Occupancy Load: Floor Trusses Stories: Exterior. Termite Letter Front Setback: Rear Setback: Shutter Fin al Left Setback: Right Setback: Roof Trusse Plans Submitted: Certification Status: Drywall Screw Stem wail Footer Certification Date: Additional Info: insulation Bond Return: Classification: Commercial Window Door Attachment Trusses Plan Submittal Final Building Fees Due Amount Total Amt Paid Amt Due F Total: $ 0.00 $ 0.00 $ 0.00 Rake Beam Second Floor Tie Bond Beam Payment Type: Density Fill Cells Columns Final PE Certification Wall Sheathing Window and Door Buck Roof Sheathing Spot Survey Footer Column Pads Slab Second Floor Slab In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Futhermore, I authorize the above -named contractor to do the work stated February 25, 2008 Authorized Signature: Owner / Applicant / Contractor / Agent Date Building Department Copy Monday, February 25, 2008 1 Miami Shores Village 10 zqe� Budding Department ��'� _ PPPrPP � 10050 N.E.2nd Avenue, Miami Shores, Florida 3313$ APP Tel: (305) 795.2204 Fag: (305) 756.8972 BUILDING Permit N o . M008 m ab PERMIT APPLICATION Master Permit No. FBC 2004 Permit Type (circle): Building Electrical Plumbing Mechanical Roofing Owner's Name (Fee Simple Titleholder) A7 4T (R OW Phone # 3Q5 -?,Z' 37 Owner's Address 0 1 101 e5 Ltd - - th S - T City f 1 Fjj�i State �P L- Zip 33 ) 6,5 Tenant/Lessee Name Phone # Job Address (where the work is being done) S 9CS33 N /7? / y City Miami Shores Village County Miami -Dade Zip 33 /Sb FOLIO / PARCEL # Is Building Historically Designated YES NO Contractor's Company Name —111Y 4. 517?j ?H Phone # 4 105 7 — 2 ,5 7 - 0222 Contractor's Address _ ' 1 ®O 5 W -'a z cS 'f City /? ° �j f�'f37) State EL Zip aX 76 Qualifier Name Af r AQ. [ Phone # State Certificate or Registration No. Certificate of Competency No. Architect/Engineer's Name (if applicable) Gi °I l� 199O /1 Phone # 2 7 Value of Work For this Permit $ - 5j O E Square ! Linear Footage Of Work: Type of Work: QAddition ❑Alteration ew ❑ Rep/Replace, ❑ Demo lition Describe Work: j5 fth Cl " E CJ C &8 AOO,j, --'T 6R 5 d e- q923 N )22 r& V Art 1~ F® 9 Can kRc- 6 ER v ice e se azrrowi sKercm Fd S b Submittal Fee $ Permit Fee $ CCF $ 1 CO /CC Notary $ Training/Education Fee$ Technology Fee $ Scanning $ Radon $ DPBR $ Zoning $ Bond $ Code Enforcement $ Double Fee $ Structural Review. $ Total Fee Now Due $ See Reverse side Bonding Company's Name (iiapplicable) ^� Bonding Company's Address City State zip Mortgage nder' Name (if applicable) Mortg�' City State zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that.no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all 'laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS; POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I !certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE,i OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good fgith that a Copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature ,�1\� _ Signature Owner or Agent Contractor The foregoing instrument was acknowledged before me thi The foregoing instrument was acknowledged before me this day of SAOM 0 9 b �" day o d .. who i ersonally known to -who has produced who s personally known to r who has produced fication and who did take an oath. as identification and who did take an oath. NOTARY BLIC• N A my ANA ML V ANA L MMII6SION # ' 418 Sign: ? S' fnn+ Pubtb Print: i'mu Prmt: (- My Commission Expires: M Commission Expires: APPLICATION APPROVED BY: Plans Examiner Engineer � Zoning (Revised 02/08/06) GENOVESE OBLOVE � BAIT I S A Ricuv4 Sa a&n Telephone (305) 349 -n3I I emuit. rsarafanfaip-iaw com Attomeys at LW October 17, 2007 Mr. Tom Benton Village Mar wl er Village of Miami Shores 10050 N.E. Second Avenue Miami Shores, Florida 33138 Re. AT & T Permit Aaaliea&= for Construction in Right of ft Dear Torn • At your request I have looked into the issue of whether or not a signature by the property "owner" should be required in connection with permit applications from AT& T to install facilities in the Village right of away. After reviewing correspondence from AT &T counsel and having discussed this matter with our building; official, I am of the opinion that these permits can be processed without any "owner" signature. It is my understanding that the primary purpose for requiring the owner signature is to protect the Village from claims by third parry owners that the Village issued permits to contractors without the consent and approval of the owner of the property. Plainly, the Village does not need its own signature to assure itself that it will not bring any future claims against itself in connection with this permit. In addition, counsel for AT&T has raised substantial issues about whether or not the Village consent is even required for the use of this right of way (an issue which need not be resolved for purposes of this opinion). If you have any questions, please do not hesitate to contact me. ery truly yours, jeq� 1�✓ RSIdr 'chard Sarafan cc: Claudio Grande Bank of Ame= Tower • 100 Southeast SewM Streer, 44th Floor • Mum. blonds 33131 • Telephone. 3053492304 * Facszn ile 305.349.231.0 h PERMIT TC :I> i PROPOSED ALP -248 CABINET PROPOSED I 4'2'WX2'2'DX4'H FPL HANDHOLE —► F_ RT -1104C r fo e I 9 N M IAMI M S 833 I I AV PROPOSED 30 1 2 j MMSHFLBF /M031U ELECTRICAL CONDUIT ��� 6' 3' 6' 10' - p m 5' SDWK 5' SDWK - a - - ®® - -__® I o PERMIT - PROPOSED Miami Shores Village 3 2 - 4' PVC APPROVED z GRASS AREA 7-71 D TE �••• j EXI S ING EPT �� : . •, •,,,, • AT &T " • .. •••• . BLDG DEPT ":'• : • „• H °PODOCARPUS° PLANTS TO BE _ .�„ • I 1> PLACED AROUND THE CABINET PER SUBJECT TO COMPLIANC TH ALL EDERAL '.,,, , CITY OF MIAMI SNORES REQUIREMENTS STATE AND COUNTY RULES AND REGULATIONS • *00 •• i 3 ... 0 •• •• 0 . • • • , i :••i•0 ••���• O : •,• �••• • ��••:• M (---------------------------------------------- - - - - -- - -- -----e/L--------------- i NE 99TH ST NOTE i AT &T WILL CUT AND RESTORE i SIDEWALK, GRASS AREA AND i ° ASPHALT. i PROPOSED 2-4” PVC BellSouth GRASS AREA ® Telecommunications SED PAVEMENT TO BE CUT PROP ON RIGHT EOFOWAY OFLITIES I N F— i F . Cut in pavement will be 30' long, 3' wide CITY OF MIAMI SHORES and 2' deep. A total of 90 sqft of I EXISTING AT &T XBOX m pavement will be removed and restored. S 9833 N MIAMI AVE TOZBE4UUPDATEDHWITHD e _< i SI ZE 40 WX55 HX22° D APPROX. d I �98' Exchange: 48 HOURS BEFORE YOU DIG CALL SUNSHINE MIAMI 4 E 1 7 ' 1-800-432-4770 Designer: 5' SDWK i IT'S THE LAW IN FLORIDA Baf no, Gitika CONSTRUCTION NOTE i CONTACT: LINAN Phone: SURVEY SITE AND SET PAD �l TICKET No.tsh 029808347 305 - 222 -8237 ELEVATION FOR A MINIMUM I ��•Z1Q` Authorization: E EL 100 YEARS FLOOD. I ��� DATE /TIME: 01/29/08 02 :56pm 8MP0503IN Dwg. I of 2 1/30/2008 7:34:35 AM A ♦ i S N/A CABINET bETAIL = GAPS I NAT 61 9 2 WX2 2 0X9 H I GONGi��T� PAP 6IZ f� i ' X6 ' I I I � I POWER I Vf Kr I GAI,- V I E W PEDESTAL TOP V I �W ••• I 0� GAPS I NET I ; ,,! • „•:, 0fr GAPS I NAT I •• • •.., , COPPER O C • !• S . , I •!.!• •!, I F • CABINET CABINET FIBER SPARE - -- ♦ - ' :♦ - i 00 .- I O - G - O O O O O ♦ i I - CONCRETE PAD, =- I ------------------------ �,` - - - - - - - ' '' - - -' ♦ - -- - - ®BellSouth , Telecommunications I 402m, PROPOSED TELEPHONE FACILITIES �, , . 4'2' I ` ON RIGHT OF WAY OF % ,1C 0 N C R E T E , PAD I CITY OF MIAMI SHORES S 9833 N MIAMI AVE I 6' Exchange: MIAMI Designer: Bafna, Gitika — — — — I Phone: �------------------------------------------------- - - - - -- 305 - 222 -8232 Authortzation: 8MP0503IN Dwg. 2 of 2 1/30/2008 7:34:36 AM ana on.1111 I.I...... i a n n Miami Shores Village Permit NO. CC-2-08-220 10050 N.E. 2nd Avenue --------------------------- ---- . ... M . ........................ Miami Shores, FL 33138-= . ........... ................ ..... Phone: (305)795-2204 Fax: 756-8972 (305) . . . . . ...... ... r ms . . . . . . ........ Issue Date: Not Issued Expires: ot ISSued Folio Number:1132060131090 Owner's Name: LENI EMMERT Owner's Phone: Job Address: 9833 MIAMI Avenue N Total Square Feet: 0 Miami Shores, FL 33138- Total Job Valuation: $5,000.00 - - ---------- Contractor(S) Phone Primary Contractor Planning and Zoning Criteria and Comments Approved: Yes Date Approved: 2/15/2008: Yes Comments: RM Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL 33138 -0000 s£ a Phone: (305)795 -2204 Expiration: 08 12312 008 Project Address Parcel Number Applicant 9833 N MIAMI Avenue 1132060131090 OSCAR EMMERT Miami Shores, FL 33138 Block: Lot Owner Information Address Phone Cell OSCAR EMMERT 9833 N MIAMI AVE MIAMI SHORES FL 33150 -1746 Contractor(s) Phone Cell Phone Valuation: $ 2,000.00 MESA ELECTRIC SYSTEMS CORP 30 5 - 279 -5498 _. _. ._,.._.____:___:::::::::::: _ ::::.. .- ._:::::. .....:.:::::::::::::_ ._ .................... ........... .......::..::::..:.. ,_,. ,:... ........ -. ..........................__... - ..._.................. - Total Sq Feet: 0 „. Type of Work: AT &T NEW CABINET Available Inspections: Additional Info: Inspection Type: Classification: Commercial Fire warm Underground Rough Final Service Change Meter Box Relocation Alteration W. W. Fees Due Amount Total Amt Paid Amt Due CCF $1.20 Education Surcharge $0.40 $ 0.00 $ 0.00 $ �-00 Permit Fee - Additions/Alterations $150.00 Scanning Fee $6.00 Payment Type: Technology Fee $3 75 Total: $161.35 . � PAI In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done.in compliance with all applicable taws regulating construction and zoning. Futhermore, I authorize the above -named contractor to do the work stated. February 25, 2008 Authorized Signature: Owner / Applicant / Contractor / Agent Date Building Department Copy Monday, February 25, 2008 1 Miami Shores Village : c�4bl � 4�r Building Department loop 10050 N.E.2nd Avenue, Miami Shores Florida 33138 �A - - Tel: (305) 795.2204 Fax: (305) 756.8972 BUILDING Permit No. PERMIT APPLICATION Master Permit No. FBC 2004 Permit Type: Electrical Owner's Name (Fee Simple Titleholder) f1"� T Phone # 3ai' 2! _g Owner's Address Gj 0 ( SW ST City _ M f M i State �'t: zip 4 5 - Tenant/Lessee Name Phone # E -MAIL: Job Address (where the work is being done) j 9,833 /J p J//y�j City Miami Shores Village County Miami -Dade Zip 33 FOLIO / PARCEL # Is Building Historically Designated YES NO V'_ Contractor's Company Name Ff IS-lk C G trfe� r r Phone # 7 If 2— Contractor's Address III-V. p S(A,) (j- ,( Ciry M l !k k% f State L • Zip '� 3/� Qualifier Name CA lt. (o S 2 M 4'S A Phone State Certificate or Registration No. 45 ( 08 / 2 g3 Certificate of Competency No. d O O0 (a 0 5� E -MAIL: Architect/Engineer's Name (if applicable) Phone # Value of Work For this Permit $ _ ,' �j (�D v Square / Linear Footage Of Work: Type of Work. ❑Addition Alteration LNew ❑ Repair /Replace ❑Demolition Describe Work: Fl � �L�C��� —A ALEIA) C.�Y�/1�16 T G " 50t ©F 9933 A �1�l�f_ &C F09 FUTU Se p, Vice 5 j9TT6CF{E S - TChl . Submittal Fee $ Permit Fee $ ( 'L� CO/CC Notary $ • """ Training /Education Fee $ •10 Technology Fee $ ✓' {5 Scanning $ Radon $ DPBR $ Zoning $ Bond $ Code Enforcement $ Double Fee $ Structural Review. $ Total Fee Now Due $ r . See Reverse side - Bonding Company 's Name (if applicable) Bonding Company's Address City State Zip Mortg�gse -*J4 r' e ( pplicable) MortgagIndet Adder: City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered.to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature Signature Owner or Agent Contractor The foregoing instrument was acknowledged before me this 6 T7-t The fore oing instrument was acknowledged before me th is C� day of �� r�� day of ®x , 20, by (� PS A- , o is personally kno;As a or who has produced who is or who has produced dentification and who did take an oath. as i entification and who did take an oath. NOTARY UBLIC: NOTARY PUB IC: Sign: Si RONIER PONCE Sign: Print: E I �NI ^ Print: * EXPIRES: June 29, 2011 Wfff My C My Commissi n Exp '* x�x * *xxKx * * * * *������ *x *� * *� *� *x *� APPLICATION APPROVED BY: I �C" Examiner Engineer Zoning (Revised 02/08/06) ."CA L OCA . . . . • . . • . . . • • • • • • • • • s • AN =40 O St MV4 FL 33165 •• • • •• ••• •• (303 279-549& AM .. .. . ....... 2006 j BST POLE o - ft ( FPL SERVICE POINT) Y PROPOSED FPL HANDHOLE _ D Miami Shores Village Z F +� bDD8 3 A PROVED BY OFfloR`OF 29,201? kTE COF M ZONING DEPT D BLDG DEPT SU BJECT TO COMPUANCE W TH ALL FEDE STATE AND COUNTY RULES AND REGULATI NS D ALP -248 CABINETT C 4'2'WX2'2'DX4'H M S 9833 NE N M AMI MMSHFLBF /M031U I I O I I I ----------------------------------------------------------------------C/L------------------------- I j � BellSouth I NE 99TH S T Telecommunications I PROPOSED TELEPHONE FACILITIES I O ON RIGHT OF WAY OF CITY OF MIAMI SHORES I i S 9833 N MIAMI AV Exchange: MIAMI Designer: Baf no, Gitika Phone: 305 - 222 -8237 Authorization: 8MP0503IN Dwg. I of 3 1/30/2008 7:35:08 AM *0 .. E • ..�T RICA .. N /A 0 • • • �II'sa Ewtni S Corr. • •.• ••. • •.. 1.12�US�N .. . .... .... _ ••• •••• •••• �I�uW,FC 33165 • ••• • • • • .... . .. ... .. (279 -5498 STANDARDS COMPLIANCE SERVICE SCHEDULE • Underwriters Laboratory, UL 50, UL 67, UL 94, UL 1950 MAIN CONDUCTORS GROUNDING CONDUIT AIC •NEC, National Electrical Cale CONDUCTOR 3 - °3 THWN AMPS IN 2' CNDT °6 CONDUIT IOK AT 24' DEPTH FPL CONTACT: q►,RTP TOTAL LOAD:35 AMPS a � » ' O PONM CARLOS BEALE * * N#DD845W FpL 30J5 -770-7927 �" +,o* � TELEPHONE CABINET NEMA 3R FACTORY WIRING XFRS SWITCH WITH 60A OCP Mechanical Interlock to Prevent Turning 'ON" at the Same Time MAIN 3 #6 BON AND GROUNDING DETAIL 60A 1#8 60A 1 #8 GROUND 3 #6 THWN GENERATOR #2 AWG BARE OUTLET SOLID TINNED EXTERNAL GROUND CONNECTIONS COPPER BURIED M (SEE NOTE G) ESA CABINET NOTES I. IF THE POWER PEDESTAL IS LOCATED ON OR WITHIN 8' OF THE 3 #6 CONCRETE CABINETS, ONLY 2 GROUND RODS ARE REQUIRED TO GROUND THE 1 # 813 FOUNDATION CABINET AND MEET THE REQUIREMENTS OF THE NEC. 3 #3 THWN CABINET PAD 2, IF THE POWER PEDESTAL IS LOCATED MORE THAN 8' AWAY FROM in 2' cond. MOUNTING THE CABINET, 2 -10' RODS REQUIRED TO GROUND THE POWER PED- PVC SCH 40 In HOLE ESTAL SPACED B' APART PER NEC 250 -52. THESE RODS MUST 24" DEPTH BE BONDED TOGETHER WITH A MINIMUM #6 AWG BARE COPPER WIRE. THE POWER SERVICE GROUND RODS AND THE CABINET ® BellSout GROUND RODS, THEY SHALL BE BONDED TOGETHER WITH #6 AWG TO FPL TO GROUND BM BARE COPPER WIRE. T eleC01'1'IP unl Cation PANEL A o 3. POWER SERVICE GROUNDING ELECTRODE CONDUCTOR SIZED PER RATINGS: 100 AMPS PROPOSED TELEPHONE FACILITIES OOPPfR ARf ® BUS NEC - 250 -66. SEE NOTE 5 ON RIGHT OF WAY OF 9 4. BOND POWER NEUTRAL BUS TO EQUIPTMENT GROUND BUS IN THE CITY OF MIAMI SHORES SEE KOBE / METER ENCLOSURE AND MAIN DISCONNECT 5 / X 10' GROUND ROD 5. PLACE A SUPPLEMENTAL GROUNDING CONDUCTOR GROUND I (SEE NOTE 7) SIZED IN ACCORDANCE WITH NEC 250 -66 DIRECT FROM THE S 9833 N MIAMI AV # ROD TELEPHONE CABINET FRAME TO THE GROUND ROD. i 6 1/2'C 6 AWG AC POWER GROUND 2' PEDESTAL 6. BURY #2 AWG SOLID TINNED COPPER WIRE 30` DEEP Exchange: 6' APART MIN. FROM (SEE NOTES 1 -5) WITHIN 2' OF CONCRETE PAD BELOW NATURAL GROUND LEVEL. MIAMI FRAME TO 2 - 5/8'X10° GROUND RING 7. GROUND RODS TO BE COVERED WITH A. DLC FLUSH MOUNT GROUND Designer: ROD CLOSURE PER 629- oI0 -90IBT FOR INSPECTION PURPOSES. GROUND ROD GIf IICd — GROUND Bafna, RING Phone: 305 - 222 -8237 Authorization: 8MP0503IN Dwg. 2 of 3 � 1/30/2008 7:35:09 AM . .... . . .. . . ...... . ... . ..... . . ....... .... . .. VRAD 7330 Bonding and Grounding .. ......... . Main AC * When installed, AC Power Pedestal sllM d;bq ••• •• e . .PWR. lone I located within Oft of the cabinet. This e�mi•ts• tin pedestal to be grounded on the cabieefi s�brru& 3 - way 3 ring ground system. Cad Weld Cad Weld * Use #6 AWG tin - plated bare solid copper wire for #2 all ground connections: * Place minimum 6" of gravel in new Power Route GND wire from AC Sub PWR Panel directly to nearest Pedestal and replace gravel in any existing AC Power Pedestal re- entered. GND rod per NEC code Section 250. Ground wire may not be spliced and should be routed as directly as possible. #2 tinned GND Wire to SAI w #6 0 a * The GND Ring must be a minimum of 12 below grade. #2 n GND Ring must also be approximately 6" to 24" from v Cr the edge of the cabinet pod. -o o n ° #2 o W W _ CA CD * Route ground wire from VRAD + Principal Bus Bar to the ground rod and cad weld in a 3 -way Install minimum of four (4) (5/8 X 8 copper dad) ground rods. connection into the ground ring. #2 Concrete Pad for QLC Cabinet * All connections to the ground ring including the attachment to * Insure no -oxide is applied to the ground rods will be Cad Weld connections. (Maximum 3 -way GND leads terminated on Cad Weld connections) No 4 -way or above connections. Principal Bus Bar. * All ground rods will be covered with a Flush Mount Ground Rod w Approved two (2) hole Closure for inspection purposes. compression connectors with * A minimum of 6 of gravel will be required in the ground rod correct dye marking must be 2 -way inspection window. used to connect the solid #2 3 -way Cad Weld * Tog ll ground conductors inside the inspection window with a conductor to the cabinet ground Cod Weld ° C� Tag. buss. #2 AWG tin - plated bare solid copper wire * Place one (1) #2 tinned ground wire from the ground ring up into the splicing chamber and terminate the ground wire on the principal ground point bus bar. w Place an additional #2 tinned ground wire (separate from the first #2 ground wire above) from the ground ring for termination by qualified designated contractor into the AC load center bus bar (AC Sub Electrical Panel). This panel is located in the splice chamber or attached to side of cabinet (as shown in figure above). * The two (2) number #2 tinned ground wires should be connected to the ground ring utilizing a Cad Weld connection. w The first ground wire will be attached on one side of the ground ring and the second ground wire will be attached at the opposite side of the ground ring (i.e. 180 degrees apart). * The termination of the #2 tinned ground wire to the principal ground point bus bar in the splicing chamber should be connected utilizing a compression type connection with two (2) hole lug ( #10 -3/8). Mechanical connections are NOT acceptable. * Place one (1) #2 tinned wire from the VRAD principal ground point bus bar over to the SAI bus bar. This attachment will provide bonding and grounding connectivity between the SAI and the VRAD. The minimum distance recommended in placing this ground wire from the VRAD to the SAI is ten (10) feet. This procedure is best completed during the placing of the copper cable between the VRAD and the SAI. (The placing process described above will allow the isolation of the ground source for testing purposes). * Installations with multiple cabinets may be enclosed in the some ground ring if the separation between pads is 36 inches or less. Equipment on pads separated by more than 36 Inches shall have a separate ground ring.. * Separate ground rings must be bonded together with a #2 AWG tin - plated bare copper conductor. * All ground rods will be covered with a Flush Mount Ground Rod Closure. A minimum of 6 inches of gravel will be required in the ground inspection windows. The gravel will be placed so that all ground connections are visible. Tog all ground conductors inside the inspection window and cabinet with a C tag. * A minimum of 6 inches of gravel will be required in the cable entrance area. 21412008 10:14:20 AM