Loading...
PL-10-1377Inspection Number: INSP - 150019 Scheduled Inspection Date: August 13, 2010 Inspector: Hernandez, Rafael Owner: MATEO, RAYMOND AND DAMARIS Job Address: 441 GRAND CONCOURSE Project: <NONE> Miami Shores, FL Contractor: AROUND THE CLOCK GAS SERVICE Building Department Comments August 12, 2010 Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 For Inspections please call: (305)762 -4949 Permit Number: PL -7 -10 -1377 Permit Type: Plumbing - Residential Inspection Type: Final Work Classification: Gas Phone Number (305)757 -4664 Parcel Number 1132060170310 Phone: 305 - 231 -3632 NATURAL GAS LINE TO TANKLESS WATER HEATER AN[ DRYER Passed Ixt Failed Correction Needed Re- Inspection Fee No Additional Inspections can be scheduled until re- inspection fee is paid. Inspector Comments Page 7 of 9 Around The Clock Gas Service, Corp. 13117 NW 107 Ave unit 17 Hialeah Gardens, FL. 33018 Phone: 305- 231-3632 Fax: 305 - 231-4180 August 10, 2010 To: Whom It May Concern in the City of Miami Shores Plumbing Department This is to cert? that Around the Clock Gas Service Corp. an authorized Advantage Dealer of Peoples Gas and Florida City Gas, has performed a drop test at the following site and tested all the appliance connections. The gas line has been checked to the standards of the 2007 Florida building code and properly tested to meet the standards of NFPA 54. The work was performed for Damaris Mateo 441 Grand Concourse Miami Shores Fl 33138. Test Pressure: 8.0 Lock up pressure: 14.2 Operating pressure: 14.0 Test time: 10 Minutes State Lic# LPG017356 Class # 803 If you should have any questions regarding this matter please do not hesitate to call us. A %ury Gonzalez President Around The Cl rck Gas Service Corp. BUILDING PERMIT APPLICATION FBC 200$ Permit Type: Plumbing Owner's Name (Fee Simple Titleholder) tit V S p�"Q (� Phone # Owner's Address 44l (7rokist 4 ( ®ta cpvik. S Q R Cit �lt'∎\ 3 State e L Zip � it TenantlLessee Name Phone # E -MAIL: Job Address (where the work is being done) City Miami Shores Village County Miami -Dade Zip FOLIO / PARCEL # k\ -3aOCo -- 'Y! 10 Is Building Historically Designated YES NO Contractor's Company Name `t ` Nr■A C�C &Ak S Phone # kg' -` 5 Value of Work For this Permit $ 0 ' 0 ' 1,0 Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 Master Permit No. 4.(-0 &l1 a s C o 4, c o v>tis e 3 Vii B '�GN�IIdI� � JUG 3 0 2010 BY: Permit No. ' T1 305 — � 4 � { g$ g6 Contractor's Address 13\ <-k- :WO ` 6 IN J R r j v\ -k 'A \ City C\ r Ve �Ac.i �Q� State T L Zip - 3 S 6 \ & Qualifier Name �n�J��( G p a WI-{�i•-1 °I- - Phone # 3? G " 3Q; — 5 3 0 State Certificate or Registration No. L` r v " \ 'S (0 Certificate of Competency No. E-MAIL: Architect/Engineer's Name (if applicable) Phone # Square / Linear Footage Of Work: Type of Work: ❑Addition ['Alteration ew EJ Repair /Replace ❑ Demolition Describe Work: t P Y Ar\ 4t: e s W pv't `P!^") * * * ** * * ***st+Y$rdex*** knF9r*oY********* k*** F **...xxxxxxx**w*oYz***wwwww**w Submittal Fee $ 5D4J Permit Fee $ /5 0. CCF $ CO /CC Notary $ Training /Education Fee $ • Technology Fee $ Scanning $ Radon $ DPBR $ Zoning $ Bond $ Code Enforcement $ Double Fee $ Structural Review. $ Total Fee Now Due $ See Reverse side -+ Bonding Company's Name (if applicable) Bonding Company's Address City State Mortgage Lender's Name (if applicable) Mortgage Lender's; Address City Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior' to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS,' rURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC OWNER'S AFFI AVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant; As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencer ent must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In th/bsence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Owner or Agent Contr. ctor The foregoing instrument was acknowledged before me this The foregoing instrument was acknowledged before me this 2 ° J , day of Z who ' ' ersonal ly kn'� wn^ 1,31—R wh NOTARY PUBLIC: Sign: Print: My Comm me or who has produced As identification and who did take an oath. (Revised 02/08/06) State Sign APPLICATION APPROVED BY: 0o4/4 2 8 - /0 personally knowo Zip 20 /0, by e or who has produced as identification and who did take an oath. NOTARY PUBLIC: My Comm Sign: mar °va Notary Public State of Florida re Edwin L Silver Print: " ' a c My Commission DD854954 �F F �O"� tX(JIfeS U3 /LU/1U93 *atx* xxux**a6*****I4****k,Y****Xd car, Y4e**** ************x,cae********xxxxxx xxxxxxw*w , Yx xxaCxeY *r. Plans ,Examiner Engineer Zoning 1/2 PSI REGULATOR AND METER TO BE SET BY NATURAL GAS COMPANY EXTERIOR TANKLESS WATER HEATER 199,000 BTU 1" OUTLET GAS DRYER 22,000 BTU 4 " OUTLET i NATURAL GAS 1/2 PSI AT METER TOTAL BTU = 221,000 GAS PIPE LONGEST RUN 25 LFT (25') TABLE 402.4(2) FOR SCHD 40 STEEL • 2 OUTLETS • 2 CONNECTS 2 — NEW APPLIANCE AS FOLLOWS • DRYER = 22,000 BTU • TANKLESS W/H = 199.000 BTU FRONT OF PROPERTY GAS SITE PLAN CAD FILE: OSO FLOORPLAN 1 of 2 RESIDENTIAL_ SITE FOR: EDAN/IAFRIS MATEO 441 GRAND CONCOURSE, MIAMI SHORES, FL 33138 AMAURY GONZALEZ — MASTER QUALIFIER — 14826 AROUND THE CLOCK GAS SERVICE CORP. GAS INSTALLERS STATE —LIC — 17356 13117 NW 107 AVE, HIALEAH GARDENS, FL 33018 Phone 305- 231 -3632 Fax 305 -231 -4180 DRAWN BY AMAURY GONZALEZ DATE: 07-29-10 REV. No. GAS UNE FROM NEW METER TO 2 NEW APPUANCE GAS UNES WILL RUN ON WALL STRAPED TO OUTSIDE & INSIDE WALL NEW GALVANIZED ONES INTERIOR AND EXTERIOR. INSTALLATION DONE IN ACCOEDANCE WITH FBC 2007 NFPA 54 AND 58 REGULATIONS AS WELL AS ALL LOCAL CODES dOSLY P oe. Notary P(blic State of Florida win ver o My Commission DD 95 'i' Expires 03/20/201 AM URY GONZAL CAD FILE: oso ISOMETRIC 2 of 2 NATURAL GAS — 1/2 PSI AT METER TOTAL BTU = 221,000 GAS PIPE LONGEST RUN 25 LFT (25') TABLE 402.4(2) FOR SCHD 40 STEEL • 2 OUTLETS • 2 CONNECTS 2 — NEW APPLIANCE AS FOLLOWS • DRYER • TANKLESS W/H = 22,000 BTU = 199.000 BTU 1/2 PSI REGULATOR AND METER TO BE SET BY NATURAL GAS COMPANY RESIDENTIAL SITE FOR: ID ANA ARIS MATED 441 GRAND CONCOURSE, MIAMI SHORES, FL 33138 AMAURY GONZALEZ - MASTER QUALIFIER - 14826 AROUND THE CLOCK GAS SERVICE CORP. GAS INSTALLERS STATE -LIC - 17356 13117 NW 107 AVE, HIALEAH GARDENS, FL 33018 Phone 305 -231 -3632 Fax 305 - 231 -4180 as EXTERIOR TANKLESS WATER HEATER 199,000 BTU 1" OUTLET DRAWN BY AMAURY GONZALEZ DATE 07 -29 -10 REV. No. GAS UNE FROM NEW METER TO 2 NEW APPLIANCE GAS UNES WILL RUN ON WALL STRAPED TO OUTSIDE & INSIDE WALL NEW GALVANIZED LINES INTERIOR AND EXTERIOR. INSTALLATION DONE IN ACCOEDANCE WITH FBC 2007 NFPA 54 AND 58 REGULATIONS AS WELL AS ALL LOCAL CODES GAS DRYER 22,000 BTU 4" OUTLET QAS S S E N S s par m� �w ® 4, Notary Public State of Florida • Edv n L Silver A AURY GONZAIiEZ PERMIT #: PL- /d -/34 MIAMI SHORES VILLAGE APPROVED BY DATE ZONING STRUCTURAL ELECTRICAL PLUMBING (. aP z. 8- ik*/ MECHANICAL BLDG. SUBJECT TO COMPLIANCE WITH ALL FEDERAL STATE AND COUNTY RULES AND REGULATIONS j Item Specification Model Name N -0751 M -OD Type Installation Outdoor, Wall Hanging Air - supply/Exhaust Power Vented Ignition Direct Ignition Operating Water Pressure 15 -150 PSI Minimum Flow Rate 0.5 GPM Gas Supply Pressure NG : 4.0" -10.5" LP : 8.0" - 14.0" Dimensions 23.6 "(Height) x 13.8 (Width) x 9.4 "(Depth) Weight 47 (pounds Water Holding Capacity -----0-Gallon Connection Sizes Water Inlet 3/4" Hot Water Outlet X14 Gas Inlet i Power Supply 120VAC(60Hz) Consumption NG: 64W LP: 77W Freeze Prevention 145W Material Casing Zincified Steel Plate / Polyester Coating Flue Collar Stainless Steel Heat Exchanger Copper Sheeting, Copper Tubing Safety Devices Flame Rod, Thermal Fuse, Lightning Protection Device (ZNR), Electric Leakage Prevention Device(GFCI), Overheat Prevention Device, Freezing Prevention Device, Fan Rotation Detector Included Accessories Remote Controller, Remote Controller Cord, Anchoring Screws Optional Accessories Isolator EXP ( #IK- WV -1), Recess Box (RB -4), Pipe Cover ( #PC -2S), Remote Controller Outdoor Junction Box ( #RC -OJB), ScaleShield ( #SS- HB-1), Quick - Connect Cable (#QC -1M) NOD Z UPPER WALL MOUNT BRACKETS LOWER WALL MOUNT BRACKETS 4 2 4. Model N -0751 M -OD Tankless Water Heater NORITZ AMERICA CORPORATION 11160 Grace Avenue. Fountain Valley, CA 92708 Tel. 1-866-7NORITZ www.noritLCOm Item Maximum Performance Minimum Performance Gas Consumption NG 199,900 btuh 12,000 btuh LP 199,900 btuh 12,000 btuh Thermal Efficiency 84% Energy Factor NG: 0.82 LP: 0.86 Hot Water Capacity 35°F Rise 9.2 Gal/min. 45°F Ri 7.5 Gal/min. 77°F Rise 4.4 Gal/min. 100°F Rise 3.4 Gal/min. Capacity Range 0.5 - 9.8 Gal/min. Temperature Settings 100-150°F (In 5°F intervals) ,160, 170, 180°F (14 Options) Default Temperature Options 120, 130, 140, 180°F (Default is 120°F) Features Quick-Connect (2 units), Pump Control, Temperature Lockout, High Elevation Adjustment Warranty 10/3- Residential, 3/3- Commercial or Circulation Use Approvals CSA, UPC, NSF Temperature Rise CF) 20 30 40 45 50 60 70 80 90 100 110 120 130 Flow Rate (GPM) 9.8 9.8 9.2 ` 7.5 6.7 5.6 4.8 4.2 3.7 3.4 3.1 2.8 2.6 12 10 30 25 120 8 6 4 *For peak flow rates in shaded areas, contact Noritz for proper setting. -1 15 2 10 5 0 0 Model N-0751 M-OD Product Performance Flow Rates 0 20 40 60 80 Temperature Rise (C) Pressure Loss 100 120 Sot temperature: 145°F or higher Set temperature: 140 or less 00 10 20 30 40 50 80 70 Flow Rate (gpm) 80 9.0 140 10.0 11.0 60 50 40 30 20 10 0 u. Noritz America reserves the right to discontinue, or change at any time, the designs and/or specifications of its products without notice. Rev.4/07 f Item Check Illustration Required Clearances From Heater • Maintain the following clearance from both combustible and non - combustible materials. * ()indicates the distance when installing a heat insulat- ing board (incombustible material other than metal, with thickness of 0.1" or more) or "section of building effec- tively finished with incombustible material." Note, however, that combustion failure may occur to the unit as exhaust gas reflects from the wall. Provide clear- ance of 24" or more in the front of the unit to facilitate inspection and repair. / 8 \\\\\\\\1 elgmsngwoo (12 24° ") m CA o or more 0.4" or more � combustible 36" or more v combusti `�\ \\ 6° or more / combustible 6" or more I Surrounding the area of installation • When installing the unit in a common side corridor, pro- vide a clearance of 47" or more in front of the unit. 0 Set the bottom edge of the exhaust port about 84 " from the corridor floor. 47" or more III / w A Handrail about 84" ® common side r corridor • When installing the unit on a balcony, etc., secure an evacuation route of 24° or more in width. • Provide clearance of 24" or more in front of the unit to facilitate inspection and repair. Do install the unit such as the wall of the second floor where the unit is out of reach. 24" or more ` """ ' A balcony, etc. ■ Handrail 6. installation Clearances 1 WARNING Before installing, check for the following: Install in accordance with relevant building and mechanical codes, as well as any local, state or national regulations, or in the absence of local and state codes, to the National Fuel Gas Code ANSI Z223.1/NFPA 54 — latest edition. In Canada, see NSCNGPIC for detailed requirements. Clearance Requirements from Vent Terminations to Building Openings * All clearance requirements are in accordance with ANSI 221.10.3 and the National Fuel Gas Code, ANSI Z223.1 and in Canada, in accordance with NSCNGPIC. 0 Vent Terminal Area Where Terminal ® Air Supply Inlet ® is Not Permitted )= indicates clearances required in Canada *Maintain clearances in accordance with local installation codes and the requirements of the gas supplier * * *A vent shall not terminate directly above a sidewalk or paved driveway that is located between two single family dwellings and serves both dwellings. * ** *Permitted only if veranda,porch,deck,or balcony is fully open on a minimum of two sides beneath the floor. Clearance Outdoor Installation (See p.8) A= Above grade, veranda, porch, deck,or balcony 12° (12 °) g Window or door that may be opened 12° (36 °) C. Permanently closed window * D= Vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 2 feet from the center of the terminal * * E= Unventilated soffit * F= Outside corner * G= Inside corner * H= Each side of center line extended above meter /regulator assembly 3' within a height 15' above meter /regulator assembly 1= Service regulator vent outlet 3' J= Nonmechanical air supply inlet or combustion air inlet to any other appliance 12° (36 °) K= Mechanical air supply inlet 3' above if within 10' (6') �— Above paved sidewalk or paved driveway located on public property ) M= Under veranda, porch, deck, or balcony (12 °_ Canada Only * ***) Clearance Requirements from Vent Terminations to Building Openings * All clearance requirements are in accordance with ANSI 221.10.3 and the National Fuel Gas Code, ANSI Z223.1 and in Canada, in accordance with NSCNGPIC. 0 Vent Terminal Area Where Terminal ® Air Supply Inlet ® is Not Permitted )= indicates clearances required in Canada *Maintain clearances in accordance with local installation codes and the requirements of the gas supplier * * *A vent shall not terminate directly above a sidewalk or paved driveway that is located between two single family dwellings and serves both dwellings. * ** *Permitted only if veranda,porch,deck,or balcony is fully open on a minimum of two sides beneath the floor. Clearance Requirements from Vent Terminations to Building Openings * All clearance requirements are in accordance with ANSI Z21.10.3 and the National Fuel Gas Code, ANSI Z223.1 and in Canada, in accordance with NSCNGPIC. * For Installations in Canada, clearances are as follows: To windows, doors, & gravity air inlets: 36 ". To forced air inlets: 6'. Maintain the following clearances to any opening in any building: Illustration , Outdoor Clearances to Opening into Any Building • 1' below, 1' horizontally from, or 1' above any door, operable window, or gravity air inlet into any building. 3' above any forced air inlet within 10'. 0� 1 ' = 1' t . C * ��J r Vent Clearances When Heater is I Installed in a Recess Box • 1' below, 1' horizontally from, or 1' above any door, operable window, or gravity air inlet into any building. 3' above any forced air inlet within 10'. 000_oo . i MEM 0 1' r - (recess box installation with cover removed) Clearance Requirements from Vent Terminations to Building Openings * All clearance requirements are in accordance with ANSI Z21.10.3 and the National Fuel Gas Code, ANSI Z223.1 and in Canada, in accordance with NSCNGPIC. * For Installations in Canada, clearances are as follows: To windows, doors, & gravity air inlets: 36 ". To forced air inlets: 6'. EM iTH 11B UNIT I ITEM SWITCH OUTLETS UNIT 1 IV_ 1 ITEM SPACE HEATERS UNIT FEE MET I LIGNi CUTLETS CENTRAL HEATING S1IY(ASHER I RECEPTACLES A/C (WIND) ISPOSAL { SERVICE TEMPORARY A/C (CENTRAL) LINKING FOUNTAIN SERVICE SIZE IN AMPS DICT WORK .D0R DRAIN SERVICE REPAIR/MTER CHANGE REFRIGERATION TEASE TRAP I APPL IANCE OUTLETS PROCESS AND PRESS PIPING .ITERCEPTOR l I RANGE TDP UNDERGROUND TANKS 4VATCRY I OVEN ABOVE GROUND TANKS ALINDRY TRAY WATER HEATER U.F. PRESSURE VESSELS _OT ES WASHER MOTORS 0- 1 HP STEAM BOILERS -TOWER MOTORS OVER 1- 3 1-P HOT WATER BOILERS INK, POT/3 COMP. MOTORS OVER 3- 5 HP MECHANICAL VENTILATION INK, RESIDENCE MOTORS OVER 5- 8 If TRANSPORTING ASSEMBLIES INK. SLOP MOTORS OVER 8- 10 If ELEVATORS/ESCALATIRS E}PORARY WATER CLOSET MOTORS OVER 10- 25 If FIRE SPRINKLER SYSTEMS RIVAL 1 MOTORS OVER 25-100 FP COOLING TOWERS ATER CLOSET 1 1 MOTORS OVER 100 HP VIOLATION NOIRECT WASTES 1 I A/C WIt1OW I REINSPECTI0N VIR SUPPLY TO: 1 AIR CONDITIONERS I I I { A/C UNIT I I I STRIP HEATER I I FIRE SPRINKLER 1 1 GENERATORS TRANSFORMERS 1 HEATER -NEW INST. 1 1 1 GENERATOtS J 1 HEATER -- REPLACE I I GENERATORS TRANSFORMI^CRS i I I I LAWN SPRINKLER -WELL I 1 SPECIAL PURPOSE I I SWIMMING POOL OUTLETS COMMERCIAL J I I WATER SERVICE SIGN TUBES 1 EWER CONNECTIONS SIGN TRANSFORMERS TILITY -SEWER SIGN TIME CLOCK _ TILITY -WATER FIXT1RES EPTIC TANK I ANTENNA ELAY TELEVISION OUTLETS RAINFIELD, 4' TILE/RES. VIOLATION 1 UMP & ABANDON SEPTIC TANK REINSPECT ION OAKAGE PIT CU. FT. AT CH BASIN L_ • ISCHARGE WELL O'M`STIC WELL REA. DRAIN OOF Kr. POPO HEATER P. STAND ' ' 1 PLUMBING ADDENDUM TO BUILUINU F Uff Arr L i VH L Z uIt AN ADPLICATION FOR BUILDING PERMIT MUST ACCOMPANT THIS ADDENDUM. IF A MAS= PERMIT HAS B. OBTAINED, THE OWNER'S NOTARIZED SIGNATURE NEED NOT BE PRESENT ON SUBSEQUENT APPLICATIONS.) ELECTRICAL MECHANICAL COL PIPING 1 1 AWN SPRINKLER SYSTEM: 1 I i & c. (L ),eOk! ETER SET (GAS) i I I 1A *-1421-J Het*.