FW-10-1699Inspection Number: INSP- 154102 Permit Number: FW -9 -10 -1699 Scheduled Inspection Date: December 29, 2010 Inspector: Bruhn, Norman Owner: CABRERA, JORGE Job Address: 9550 N BAYSHORE Drive Miami Shores, FL 33138- Project: <NONE> Contractor: ISLAND FENCE OF FLORIDA INC Building Department Comments Passed Failed Correction Needed Re- Inspection Fee No Additional Inspections can be scheduled until re- inspection fee is paid. Inspector Comments CREATED AS REINSPECTION FOR INSP- 153582. CREATED AS REINSPECTION FOR INSP- 151604. Permit must be posted. NB Fence must reject a 4" sphere and gates must be self closing self latching. NB 290 ALUMINUM PICKET FENCE 5' HIGH December 28, 2010 Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 For Inspections please call: (305)762 -4949 Permit Type: Fence/Wall Inspection Type: Final Work Classification: Iron/Ornamental Phone Number Parcel Number 1132060143860 Phone: 305 - 888 -9090 Page 5 of 10 A RECORDED COPY MUST BE POSTED ON THE JOB SITE AT TIME OF FIRST INSPECTION PERMIT NO. TAX FOLIO NO. i 32f-x0.94 ttrici'''' STATE OF FLORIDA i Kz_AEtt6' cg, COUNTY OF DADE oe,v1hh- as , • • 0 . & THE UNDERSIGNED hereby gives notice that improvements will be made to. ti ' '',- fL ::1` certain real property, and in accordance with Chapter 713, Florida Statute e. the following information is provided in this Notice of Commencement: j.7 insur e. /Aly1111111111 A ...Id .., 1. Legal description of property and street address: e / Z..5"' of- 1.-01 2- („Sor'5,4 , 1.) / . • .41 e 125 - 1- ITex,+ 3 04C-- /2.5' # L-fr 14 or4.5' 5. 3. 5 fig- gq 2. Description of improvement: e a . / 0 4 {-t-/AA-1 ft (..J 1 cM 5 ' 3. Owner (s) name and addressql) 01:11 A 1 - ) 1 , --e- Dr. Aite. 0-4p_s fr.- 3,i Interest in property: Name and address of fee simple titleholder: 4. Contractor's name and address: :,..2-5-(at..4-44. 6 "F t 3 - SYN-qc) 90 1 9, 0 iezzer_14.4) 44, th AL 3 30 / 5. Surety: (Payment bond required by owner from contractor, if any) Name and address: Amount of bond: $ Ai/A 6. Lender's name and address: NOTICE OF COMMENCEMENT 11 11111111 11 1111111 111 11111111 11 11111111 1 1111 CFN 2010R0654872 OR Bk 27434 Ps 3497; (lps) RECORDED 09/27/2010 15:55:28 HARVEY RUVIHr CLERK OF COURT MIAMI-DADE COUNTY, FLORIDA LAST PAGE - AZ 7. Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 713.13 (1) (a) 7., Florida Statutes: Name and address: 81n addition to himself, Owner designates the following person (s) to receive a copy of the Lknor's Notice as provided in Section 713. 13 (1) (b) 7., Florida Statutes: Name and address: on 1 of this Notice of Commencement (the expirati date is 1 year from the date of recording unless a different date is specified) • 110 ' O ■ _ J P; - of Owner _, ,., IF t Owner's Name ja/laE. 06't#, Sworn to and Notary Public Print Notary's Name Prepared by: Kte-iy L 4e2-- 'bed before me this 1 day of Address: / 0 te-e-o-g-ka o(f-lyt& iede-Aft-A, FL 33 My Commission Expires: /--/ V 0 Fenn 104 1 ■4q ‘ 444-443- BUILDING PERMIT APPLICATION FBC 2001 City H :3- 1 c: Tenant/Lessee Name Miami Shores Village Building D epartment 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 Permit Type (circle): ( Building Electrical Plumbing Mechanical Roofing Owner's Name (Fee Simple Titlefiolder) \�J O r c ° J v Cc, Phone # Owner's Address 7 S s'V e 704. State t-=-_- Zip 3 / 3 e Phone # Job Address (where the work is being done) t / j7) /J ' 3 ( ,, 0 / Cit Miami Shores Village County Miami -Dade Zip 3 _3 / .3 Is Building Historically Designated YES NO Contractor's Company Name �Gj- /0_41.c.1 ✓1C. 0 -r 4; f phone # Contractor's Address / 1 tr - O/t i1 -6k ?) Cam- /20 City 1 4) f04-€2011 State ` L_ Zip Qualifier ) i C (Flo `'� `s 2'. State Certificate or Registration No. Certificate of Competency No. Lt 2 / ,� 0 C 7 Architect /Engineer's Name (if applicable) Phone # $ Value of Work For this Permit Submittal Fee $ Notary $ Scanning $ Radon $ )o o 2 4 / / , 1 L . / , 1 4 1 6 4(c 7 e * * * * * * * * * * ** F ees * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** c.)/ Sgttafe•Footage Of Work: Training/Education Fee $ Technology Fee $ Zoning Bond $ Code Enforcement $ Structural Plan Review. $ Total Fee Now Due $ 2d1 tiiLJ D (Continued on opposite side) Permit No. -t''"" rO \ C) Master Permit No. 30.5 'g 9 09 Type of Work: ❑Addition ❑Alterationew ❑ Repair /Replace ❑ Demolition Describe Work: d Permit Fee $ � c;' CCF $ CO /CC Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first insp - t. hich occurs seven (7) days after the building permit is issued In the absence of wch posted notice, the inspection wil of j ro � and a reinspection fee will be charged. Signatur Owner or Agent The foregoi instrument was acknowledged before me this / 0 day of .`3�" 2/ , 20 / t. by `✓ ci► IZ' , who is personally known to me or who has produced b( As identification and who did take an oath. NOTAR UBLIC: ,, NOTARY PUBLIC: Sign: Sign: Print: f iTv , . 1 Print: My Commission Expires APPLICATION APPROVED BY: Chc 05/13/03 Signature Contractor The foregoing instrument was acknowledged before me this G day of % , 20i 2010, by f9CC4 Ct ( who is personally known't ? me or who has produced XPIRES:January 2, 20 4 ladrifittglotary Public Underwriters My C /c ; entification and who did take an oath. ( / c ********************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** ****** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Plans Examiner Engineer Zoning STATE OF FLORIDA) COUNTY OF DADE) tit C Witness(sign and print) •"" i EVELYN L PASCAL 1.44 n� %" ,., s MY COMMISSION # DD 940519 c• J-' s 9oMed Tbtu Public Unde AFFIDAVIT The undersigned Affiant, 'Q oil._ , does hereby attest that the (property owner) attached survey, performed by 5„ u (name of surveyor's company) • performed on q / 2-9 (° , is an accurate representation of the existing conditions and (date of survey) locations of all structures on the property as of this date. The purpose of this Affidavit is to induce Miami Shores Village to issue a buildingpermit for the property without first providing a survey less than six (6) months old. The Affiant, as property owner, further agrees to remove or obtain permits for any structures which now may exist on the property which are not permitted or which may violate zoning or building code regulations. The Affiant further understands that the existence of any such structures may affect final inspections as applicab . • is or other permits.. Further, Affiant sayeth naught. SWORN TO AND SUBSCRIBED before me this / 0 day of Witn print) Affiant is personally known to me, produced bL as identification. PROJECT: CLIENT: DE No.: Description: DATE: No. of Pages: DAVIS ENGINEERS 780 TAMIAMI CANAL ROAD — MIAMI, FLORIDA 33144 PHONE: 305- 266 -2566 FAX: 305 - 267 -1556 E -mail: projects@davisengrs.com Island Fence Island Fence 2K1 0 -080 Aluminum Picket Fence September 15, 2010 Harold R. Cobb, P.E. Structural Engineer FL. No.: 10993 O.L. #:127365 E.B. #: 0001809 Structural Calculations R: \DE PROJECT CORRESPONDENCE\O -DE Project Correspondance12K10000\2K10 -080 - 20100915 - COV - Island Fence - Aluminum Picket Fence.doc DAVIS 780 TAMIAMI CANAL PHONE: ENGINEERS ROAD — MIAMI, FLORIDA 33144 305 - 267 -1556 E -mail: projects@davisengrs.com O.L. #:127365 E.B. #: 0001809 305 - 266 -2566 FAX: I 4 1 Codes Materials: (1) FBC — 2007 (2) ACI — 318/05 (3) ASCE 7 -05 (4) AISC — ASD (13th Ed.) (5) ACI — 530/05 (6) NDS —1997 (7) NCMA - 1997 (1) Concrete, fc = 3,000 psi (U.O.N.) (2) Reinforcing Steel, fy = 60,000 psi — ASTM A 615, Grade 60 (U.O.N.) (3) Structural Steel, Fy = 50,000 psi — ASTM A 572, Grade 50 (U.O.N.) (4) Steel Tube, Fy = 42,000 psi — ASTM A 500 Grade B (U.O.N.) (5) Steel Pipe, Fy = 35,000 psi — ASTM A53 Grade E (U.N.O.) (6) Masonry, fm = 1,500 psi (U.N.O.) (7) Aluminum, AL- 6061 -T6 (U.N.O.) (8) Wood, Fb = 1,200 psi (U.N.O.) (9) Anchor Rods, ASTM A 307 (U.N.0) (10) Bolting Materials, ASTM A 3250 or A 490 (U.N.O.) Table of Content: Page Description 1 4' High Gate 17 5' High Gate 29 6' High Gate 0 Notes: If you have any questions, please call us at 305 - 266 -2566 GENERAL NOTES; PEDESTRIAN RAIUNG DESIGN CRITERIA: 1. ALL WORK SHALL CONFORM TO FLORIDA BUILDING CODE 2007 2. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS IN THE FIELD PRIOR TO START OF WORK AND NOTIFY ARCHITECT/ENGINEER OF ANY DISCREPANCY IN THE DRAWINGS AND OBTAIN HIS APPROVAL BEFORE PROCEEDING WITH WORK. 3. THIS WORK REQUIRES A BUILDING PERMIT. DO NOT BEGIN WORKING UNTIL A BUILDING PERMIT IS OBTAINED. 4. CONTRACTOR TO FURNISH ALL LABOR, MATERIALS, SERVICES AND EQUIPMENT NECESSARY TO COMPLETE ALL WORK SHOWN ON THE DRAWINGS AND SPECIFIED HEREIN. 5. DO NOT SCALE DRAWINGS, DIMENSIONS GOVERN. 8. ENGINEERS VISITS TO THE SITE DURING CONSTRUCTION SHALL BE SCHEDULED WITHIN 24 HOURS IN ADVANCE PRIOR TO INSPECTION. 7. THE CONTRACTOR SHALL NOT PROCEED WITH ANY ADDITIONAL SERVICES OR WORK WITHOUT PRIOR NOTIFICATION TO THE OWNER, FOLLOWED BY A CHANGE ORDER. 8. THE CONTRACTOR SHALL MAKE REQUIRED ARRANGEMENTS, SECURE AND PAY FOR ALL , BARRICADES, ENCLOSURES, AND FENCING AS NEEDED FOR AND DURING THE PROGRESS TO PROTECT ADJACENT PROPERTIES. 9. DO NOT SUBSTITUTE MATERIALS, EQUIPMENTS OR METHODS OF CONSTRUCTION UNLESS SUCH SUBSTITUTIONS OR CHANGES HAVE BEEN APPROVED IN WRITING BY THE OWNER/ENGINEER. 10. CONTRACTOR SHALL MAINTAIN AN ACCURATE RECORD OF CHANGE ORDERS AND VARIATIONS THROUGHOUT THE PROGRESS OF THE WORK. USE ONE SET OF DOCUMENTS EXCLUSIVELY FOR THIS JOB. 11. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR MEANS AND METHODS OF CONSTRUCTION, AND FOR THE SEQUENCES AND PROCEDURES TO BE USED. 1. LOADS AT THE TOP RAILINGS AND HANDRAILS: UNIFORM LOAD OF w EQUAL TO 50pIf ACTING IN AND OUT IN THE HORIZONTAL DIRECTION, AND UP AND DOWN IN THE VERTICAL DIRECTION ALONG THE TOP RAILING AND HANDRAIL, BUT NOT IN A HORIZONTAL AND VERTICAL DIRECTION AT THE SAME TIME OR A CONCENTRATED LOAD OF P EQUAL TO 200 LBS AT THE MIDSPAN OF THE TOP RAILING AND HANDRAIL ACTING IN AND OUT IN THE HORIZONTAL DIRECTION, AND UP AND DOWN IN THE VERTICAL DIRECTION, BUT NOT IN A HORIZONTAL AND VERTICAL DIRECTION AT THE SAME TIME, WHICHEVER IS MOST CRITICAL THE UNIFORM LOAD AND CONCENTRATED LOAD SHALL BE ASSUMED TO NOT ACT AT THE SAME TIME. 2. LOADS AT POSTS AND AT BRACKETS AT HANDRAILS: UNIFORM LOAD OF w EQUAL TO 50 POUNDS PER LINEAL FOOT ACTING IN AN IN AND OUT HORIZONTAL DIRECTION AND IN AN UP AND DOWN VERTICAL DIRECTION ALONG THE TOP RAILING AND HANDRAIL BUT NOT IN A HORIZONTAL AND VERTICAL DIRECTION AT THE SAME TIME OR A CONCENTRATED LOAD OF P EQUAL TO 200 POUNDS AT THE TOP OF THE TOP RAILING AND BRACKET AT THE HANDRAIL AT THE POST AND HANDRAIL BRACKET, RESPECTIVELY ACTING IN AN IN AND OUT HORIZONTAL DIRECTION AND IN AN UP AND DOWN VERTICAL DIRECTION, BUT NOT IN A HORIZONTAL AND VERTICAL DIRECTION AT THE SAME TIME, WHICHEVER IS MOST CRITICAL THE UNIFORM LOAD AND CONCENTRATED LOAD SHALL BE ASSUMED TO NOT ACT AT THE SAME TIME. 3. LOADS AT ALL MEMBERS LOCATED BELOW THE TOP RAIL AND BETWEEN THE POSTS: UNIFORM LOAD OF w EQUAL TO 25 POUNDS PER SQUARE FOOT ACTING IN AN IN AND OUT HORIZONTAL DIRECTION. 4. SAFEGUARDS IN AND AROUND BUILDINGS OF GROUP R OCCUPANCIES SHALL PROVIDE PROTECTION FOR CHILDREN BY PROVIDING ADDITIONAL RAILS, VERTICAL PICKETS OR AN ORNAMENTAL FILLER BELOW THE TOP RAIL WHICH WILL REJECT A 4' DIAMETER OBJECT; PERMITTING, HOWEVER, SUCH ORNAMENTAL FILLERS TO HAVE INDIVIDUAL OPENINGS NOT EXCEEDING 64 SQ. INCHES IN AREA 5. THE MAXIMUM CLEARANCE BETWEEN THE BOTTOM RAIL AND THE ADJACENT SURFACE SHALL NOT EXCEED 2', THE 2' CLEARANCE SHALL BE MEASURED FROM THE BOTTOM RAIL OF THE BALUSTRADE TO A LINE PASSING THROUGH THE TREAD NOSINGS. STEEL RAIUNG NOTES: ALUMINUM RAIUNG NOTES: 1. ALL STRUCTURAL STEEL SHALL BE ASTM A36 (U.N.0.) 2. ALL SHOP CONNECTIONS TO BE MADE WITH ASTM A325 BOLTS OR WELDED USING E70 ELECTRODES AND SHALL CONFORM TO THE SPECIFICATIONS SET FORTH IN THE AWS STRUCTURAL WELDING CODE. 3. STRUCTURAL STEEL SHALL RECEIVE ONE COAT SHOP PAINT AND RE -TOUCH AFTER ERECTION. 4. STRUCTURAL TUBE SHALL BE ASTM A 500 GRADE B. 5. STRUCTURAALL WELDING SHALL BE PERFORMED BY CERTIFIED WELDERS PER AWS °STANDARD QUALIFICATIONS PROCEDURE` TO PERFORM TYPE OF WORK REQUIRED. ALL WELDING SHALL BE IN ACCORDANCE WITH AWS WELDING CODE. 6. STEEL STAIR AND RAILING SYSTEMS USED IN EXTERIOR APPLICATIONS AND /OR EXPOSED TO ADVERSE CONDITIONS MUST BE PROPERLY AND REGULARY MAINTAINED TO MINIMIZE CORROSION CAN RESULT IN EVENTUAL STRUCTURAL FAILURE. 7. ALL CONNECTIONS TO BE WELDED USE 3/16' MIN. WELD SIZE, TYPICAL U.N.OL PIPE SHALL BE ASTM A 53 TYPE E. GRADE B. 1. ALL ALUMINUM SHALL BE TYPE 6061 -T6, UNLESS NOTED OTHERWISE (U.N.0.) 2. BOLTS & OTHER FASTENERS DIRECTLY IN CONTACT WITH ALUMINUM MEMBERS SHALL BE ALUMINUM, STAINLESS STEEL OR ELECTRO GALVANIZED STEEL DOUBLE CADMIUM PLATED STEEL BOLTS MAY BE ALLOWED UPON WRITTEN REQUEST TO THE ENGINEER OF RECORD. 3. ALUMINUM PARTS SHALL BE WELDED WITH AN INERT -GAS SHIELDED ARC OR RESISTANCE WELDING PROCESS. FLUX WELDING IS NOT ALLOWED. FILLER ALLOYS SHALL BE AS AMERICAN WELDING SOCIETY SPECIFICATIONS A5.10 -69. ALL WELDING SHALL BE PERFORMED BY CERTIFIED WELDERS. 4. DURING ERECTION, ALUMINUM STRUCTURES SHALL BE ADEQUATELY BRACED AND FASTENED TO RESIST DEAD, WIND AND ERECTION LOADS. 5. ALUMINUM IN CONTACT WITH NON - COMPATIBLE METALS SUCH AS STEEL SHALL BE PROTECTED AS PER FBC 2003.8.4.2. 6. ALUMINUM IN CONTACT WITH CONCRETE SHALL BE PROTECTED WITH AN ALKALI RESISTANT COATING. 7. ALUMINUM IN CONTACT WITH WOOD SHALL BE PROTECTED WITH TWO COATS OF ALUMINUM METAL -AND- MASONRY PAINT. 8. ALL CONECTIONS TO BE WELDED. U55 3/16' MINIMUM WELD SIZE, TYPICAL U.N.O. DAVIS ENGINEERS 780 TAMIAMI CANAL ROAD - MIAMI, FLORIDA 33144 PHONE: 305- 266 -2566 FAX: 305 - 267 -1556 E -mail: projects 0 davisengrs.com O.L. #:127365 E.B. #: 0001809 Alluminu Picket Fence Post Embedments Post section properties Gate Dimentions Post Spaciong Hight of Post(H) Design loads: Wind Presure =g: "' Lb /sf % of Solid surface Pwind 267.6 Lb Check For Solid Signs Design Load M(Max(B,L)) 4 ft N(Min(B,L)) 4 ft M /N= 1.00 Net Force Coef. Cf= 1.2 Gust Effect Factor (G)= 0.85 Psolid sign = qz(h)xGxCf Check Post Embedment Load Due To Psolid = Moment Due To Psolid= Allow Lat Soil- Bearing pressure capacity based on 1/3 of emb. Initial Guess For D S1 =2 x SO x 0.333D Footing Width A(d)= (2.34 *P) /(S1 *B) D(d)= Ft Ft Psf Lb 545.904 Lb -FT Job# 2k10 -080 150 Lb /Ft3 (As per UBC Table 18 -1A) Depht = 0.5xA(d)x {1 +SQRT[(1 +[(4.36h) /A(d)])]} 299.7 Lb /Ft2 ft 1.07 ft 2.82 ft OK Area 0.4842 in perimeter 8 in X- centroid 1 in Y- centroid 1 in Ix 0.7878 in4 ly 0.7878 in4 ixy 0.4844 in4 rx 1.2755 in ry 1.2755 in ix -y 0.3032 in4 jx -y 0.3032 in4 r Davis Engineers Alluminu Picket Fence Post Section Properties 2 x 2 x 0.0625 6061 -T6 Aluminum 1 Sx= I I sr- I Fb= Fy= 19000 psi E= 10100000 psi Ix _♦ Y- centroid ly ---. X- centroid fy fZ -_ Check Bending & Deflection(LJ240max) M at base of footing = 545.904 Lbs -ft 6550.848 Lbs -inch Sx Req= Date 7/29/2010 Job# 2k10 -080 It= 1.2 sale!) iacwr tas per horn edition) I 0.7878 in3 I 0.7878 in3 1 15,833.33 psi 1 0.41 in3 Ok. Ix Req= 0.208 in4 Ok. Area 0.3594 in perimeter 6 in X- centroid 1 in Y- centroid 0.5 in Ix 0.1518 in4 ly 0.5453 in4 by 0.1797 in4 rx 0.65 in ry 1.2319 in ix -y 0.062 in4 jx -y 0.186 in4 Davis Engineers Alluminu Picket Fence Hotizontal members Section Properties I 1 x 2 x 0.0625" 6061 -T6 Aluminum 1 Fy= 19000 psi E= 10100000 psi 1 Sx= I Fb= Ix _♦ Y- centroid ly _♦ X- centroid fy Check bending and Defelction(L/240max) trib(50% oppened).= 2 ft W= wind pressure *trit 22.077 Lb /ft M= 1.25W(LA2)= 44.154 Lb -ft 529.848 Lb -Inch Date 7/29/2010 Job# 2k10 -080 U= 1.2 I 0.3036 in3 0.5453 in3 1 15,833.33 psi 1 Sxreq= 0.033464 in 3 OK Ix req= 0.06 OK if Ix N.G trial ly= 0.5453 in4 OK safety factor (as per AISC 13th edition) Area 02343 in perimeter 4 in X- centroid 0.5 in Y- centroid 1 in Ix 0.0931 in4 ly 0.0931 in4 Ixy 0.0586 in4 rx 0.6303 in ry 0.6303 in ix -y 0.0344 in4 jx -y 0.0344 in4 Davis Engineers Alluminu Picket Fence vertical members Section Properties 1 1 x 1 x 0.0625" 6061 -T6 Aluminum 1 Fb= I Fy= 19000 psi E= 10100000 psi Ix Y- centroid ly -► X- centroid Check bending and Defelction(IJ240max) trib(1" oppened).= 0.1 ft W= wind pressure *trit 1.10385 Lb /ft M= 1.25W(L ^2)= fy f2 -► 2.2077 Lb -ft 26.4924 Lb -Inch Date 7/29/2010 Job# 2k10 -080 U = 1.2 I 0.0931 in3 1 I 0.1862 in3 1 15,833.33 psi 1 Sxreq= 0.001673 in 3 OK Ix req= 0.003148 in4 OK safety factor (as per AISC 13th edition) Davis Engineers Alluminu Picket Fence Post Embedments Post section properties Gate Dimentions Post Spaciong Hight of Post(H) Design Toads: Wind Presure x ®� Lb /sf % of Solid surface Pwind 267.6 Lb Check For Solid Signs Design Load M(Max(B,L)) 5 ft N(Min(B,L)) 4 ft M/N= 1.25 Net Force Coef. Cf= 1.2 Gust Effect Factor (G)= 0.85 Psolid sign = qz(h)xGxCf Check Post Embedment Load Due To Psolid = Moment Due To Psolid= Ft Ft Psf Lb 682.38 Lb -FT Date 7/29/2010 Job# 2k10 -080 d Allow Lat Soil- Bearing pressure capacity based on 1/3 of emb. 150 Lb /Ft3 (As per UBC Table 18 -1A) Initial Guess For D Depht = 0. 5xA( d)x {1 +SQRT[(1 +[(4.36h) /A(d)])]} S1 =2 x SO x 0.333D 349.65 Lb /Ft2 Footing Width :-t ft A(d)= (2.34 *P) /(S1 *B) 1.14 ft D(d)= 3.02 ft OK Area 0.4842 in perimeter 8 in X- centroid 1 in Y- centroid 1 in Ix 0.7878 in4 ly 0.7878 in4 Ixy 0.4844 in4 rx 1.2755 in ry 1.2755 in ix -y 0.3032 in4 jx -y 0.3032 in4 Davis Engineers Alluminu Picket Fence Post Section Properties 2 x 2 x 0.0625 6061 -T6 Aluminum 1 Fy= 19000 psi E= 10100000 psi Is Y=I Ix __ Y- centroid ly ---► X- centroid fy 0 Check Bending & Deflection(L/240max) Sx Req= Date 7/29/2010 Job# 2k10 -080 2= 1.2 surely rucLor kus per MI .# I 311 edition) I 0.7878 in3 I 0.7878 in3 1 15,833.33 psi 1 M at base of footing= 682.38 Lbs -ft 8188.56 Lbs -inch 0.52 in3 Ok. Ix Req= 0.259 in4 Ok. Area 0.3594 in perimeter 6 in X- centroid 1 in Y- centroid 0.5 in Ix 0.1518 in4 ly 0.5453 in4 Ixy 0.1797 in4 rx 0.65 in ry 1.2319 in ix -y 0.062 in4 jx -y 0.186 in4 r ° 1 Davis Engineers Alluminu Picket Fence Hotizontal members Section Properties I 1 x 2 x 0.0625" 6061 -T6 Aluminum 1 Fy= 19000 psi E= 10100000 psi 1 Sx= I Ix Y- centroid ly -♦ X- centroid ty a Check bending and Defelction(11240max) trib(50% oppened).= 2 ft W= wind pressure *tit 22.077 Lb /ft M= 1.25W(L ^2)= 68.99063 Lb -ft 827.8875 Lb -Inch Date 7/29/2010 Job# 2k10 -080 Sl= 1.2 I 0.3036 in3 1 I 0.5453 in3 1 15,833.33 psi Sxreq= 0.052288 in 3 OK Ix req= 0.12 OK if Ix N.G trial Iy= 0.5453 in4 OK safety factor (as per AISC 13th edition) Area 0.2343 in perimeter 4 in X- centroid 0.5 in Y- centroid 1 in Ix 0.0931 in4 ly 0.0931 in4 Ixy 0.0586 in4 rx 0.6303 in ry 0.6303 in ix -y 0.0344 in4 jx -y 0.0344 in4 Davis Engineers Alluminu Picket Fence vertical members Section Properties 1 x 1 x 0.0625" 6061 -T6 Aluminum 1 I s x= I Fy= 19000 psi E= 10100000 psi Ix Y- centroid ly --► X- centroid fy 0 Check bending and Defelction(L/240max) trib(1" oppened).= 0.1 ft W= wind pressure *tit 1.10385 Lb /ft M= 1.25W(L ^2)= 2.2077 Lb -ft 26.4924 Lb -Inch Date 7/29/2010 Job# 2k10 -080 SU= 1.2 I 0.0931 in3 1 I 0.1862 in3 1 15,833.33 psi 1 Sxreq= 0.001673 in 3 OK Ix req= 0.006148 in4 OK safety factor (as per AISC 13th edition) Davis Engineers Alluminu Picket Fence Post Embedments Post section properties Gate Dimentions Post Spaciong Hight of Post(H) Design loads: Wind Presure % of Solid surface Pwind Check For Solid Signs Design Load M(Max(B,L)) N(Min(B,L)) M /N= Net Force Coef. Cf= Gust Effect Factor (G)= Psolid sign = qz(h)xGxCf Check Post Embedment Load Due To Psolid = Moment Due To Psolid= Allow Lat Soil- Bearing pressure capacity based on 1/3 of emb. Initial Guess For D S1=2 x SO x 0.333D Footing Width A(d)= (2.34 *P) /(S1 *B) D(d)= Ft Ft 267.6 Lb E ft 4ft 1.50 1.2 0.85 Lb /sf Psf Lb 818.856 Lb -FT Date 7/29/2010 Job# 2k10 -080 W H d h 150 Lb /Ft3 (As per UBC Table 18 -1A) Depht = 0. 5xA( d)x {1 +SQRT[(1 +[(4.36h) /A(d)])]} 374.625 Lb /Ft2 ft 1.28 ft 3.38 ft OK Area 0.4842 in perimeter 8 in X- centroid 1 in Y- centroid 1 in Ix 0.7878 in4 ly 0.7878 in4 Ixy 0.4844 in4 rx 1.2755 in ry 1.2755 in ix -y 0.3032 in4 jx -y 0.3032 in4 Davis Engineers Alluminu Picket Fence Post Section Properties 2 x 2 x 0.0625 6061 -T6 Aluminum 1 1 Sx Fy= 19000 psi E= 10100000 psi Y- centroid I �_ S I IY X- centroid —� fy Check Bending & Deflection(11240max) Sx Req= Date 7/29/2010 Job# 2k10 -080 12= 1.2 safely idcwr Uas per HIM. r�ur edition) I 0.7878 in3 1 I 0.7878 in3 1 15,833.33 psi 1 M at base of footing= 818.856 Lbs -ft 9826.272 Lbs -inch 0.62 in3 Ok. Ix Req= 0.311 in4 Ok. Area 0.3594 in perimeter 6 in X- centroid 1 in Y- centroid 0.5 in Ix 0.1518 in4 ly 0.5453 in4 Ixy 0.1797 in4 rx 0.65 in ry 1.2319 in ix -y 0.062 in4 jx -y 0.186 in4 Davis Engineers Alluminu Picket Fence Hotizontal members Section Properties 1 x 2 x 0.0625" 6061 -T6 Aluminum I I sY= I Fb= Fy= 19000 psi E= 10100000 psi Ix __ Y- centroid ly -► X- centroid fy Check bending and Defelction(L/240max) trib(50% oppened).= 2 ft W= wind pressure *tit 22.077 Lb /ft M= 1.25W(L "2)= 99.3465 Lb -ft 1192.158 Lb -Inch Date 7/29/2010 Job# 2k10 -080 Sl= 1.2 I 0.3036 in3 I 0.5453 in3 1 15,833.33 psi i Sxreq= 0.075294 in 3 OK Ix req= 0.21 NG if Ix N.G trial ly= 0.5453 in4 OK safety factor (as per AISC 13th edition) Area 0.2343 in perimeter 4 in X- centroid 0.5 in Y- centroid 1 in Ix 0.0931 in4 ly 0.0931 in4 Ixy 0.0586 in4 rx 0.6303 in ry 0.6303 in ix -y 0.0344 in4 jx -y 0.0344 in4 Davis Engineers Alluminu Picket Fence vertical members Section Properties 1 x 1 x 0.0625" 6061 -T6 Aluminum 1 Fy= 19000 psi E= 10100000 psi Fb= I Ix _0" Y- centroid ly -► X- centroid ty Check bending and Defelction(U240max) trib(1" oppened).= 0.1 ft W= wind pressure *tit 1.10385 Lb /ft M= 1.25W(L ^2)= 2.2077 Lb -ft 26.4924 Lb -Inch Date 7/29/2010 Job# 2k10 -080 11= 1.2 I 0.0931 in3 1 0.1862 in3 1 15,833.33 psi 1 Sxreq= 0.001673 in 3 OK Ix req= 0.010623 in4 OK safety factor (as per AISC 13th edition) Davis Engineers Alluminu Picket Fence Post Embedments Post section properties Gate Dimentions Post Spaciong Hight of Post(H) Design Toads: Wind Presure U @4 ; �, Lb /sf % of Solid surface Pwind 334.5 Lb Check For Solid Signs Design Load M(Max(B,L)) 4 ft N(Min(B,L)) 5 ft M /N= 0.80 Net Force Coef. Cf= 1.2 Gust Effect Factor (G)= 0.85 Psolid sign = qz(h)xGxCf Check Post Embedment Load Due To Psolid = Moment Due To Psolid= Ft Ft Psf Lb 682.38 Lb -FT Date 7/29/2010 Job# 2k10 -080 d Allow Lat Soil- Bearing pressure capacity based on 1/3 of emb. 150 Lb /Ft3 (As per UBC Table 18 -1A) Initial Guess For D Depht = 0. 5xA( d)x {1 +SQRT[(1 +[(4.36h) /A(d)])]) S1 =2 x SO x 0.333D 349.65 Lb /Ft2 Footing Width ft A(d)= (2.34 *P) /(S1 *B) 0.91 ft D(d)= 2.64 ft OK Area 0.4842 in perimeter 8 in X- centroid 1 in Y- centroid 1 in Ix 0.7878 in4 ly 0.7878 in4 Ixy 0.4844 in4 rx 1.2755 in ry 1.2755 in ix -y 0.3032 in4 jx -y 0.3032 in4 Davis Engineers Alluminu Picket Fence Post Section Properties 2 x 2 x 0.0625 6061 -T6 Aluminum Fy= 19000 psi E= 10100000 psi Ix Y- centroid ly X- centroid fy a Check Bending & Deflection(LJ240max) M at base of footing= Sx Req= Date 7/29/2010 Job# 2k10 -080 S1= 1.2 sarety racaor tas per HIOL. 13ui edition) I 0.7878 in3 1 0.7878 in3 1 15,833.33 psi 1 682.38 Lbs -ft 8188.56 Lbs -inch 0.52 in3 Ok. Ix Req= 0.324 in4 Ok. Area 0.3594 in perimeter 6 in X- centroid 1 in Y- centroid 0.5 in Ix 0.1518 in4 ly 0.5453 in4 Ixy 0.1797 in4 rx 0.65 in ry 1.2319 in ix -y 0.062 in4 jx -y 0.186 in4 Davis Engineers Alluminu Picket Fence Hotizontal members Section Properties I 1 x 2 x 0.0625" 6061 -T6 Aluminum 1 1 Sx= I Fy= 19000 psi E= 10100000 psi Ix Y- centroid ly - X- centroid fy Check bending and Defelction(L/240max) trib(50% oppened).= 2.5 ft W= wind pressure *trit 27.59625 Lb /ft M= 1.25W(LA2)= 55.1925 Lb -ft 662.31 Lb -Inch Date 7/29/2010 Job# 2k10 -080 U= 1.2 I 0.3036 in3 1 1 0.5453 in3 1 15,833.33 psi 1 Sxreq= 0.04183 in 3 OK Ix req= 0.08 OK if Ix N.G trial Iy= 0.5453 in4 OK safety factor (as per AISC 13th edition) Area 0.2343 in perimeter 4 in X- centroid 0.5 in Y- centroid 1 in Ix 0.0931 in4 ly 0.0931 in4 Ixy 0.0586 in4 rx 0.6303 in ry 0.6303 in ix -y 0.0344 in4 jx -y 0.0344 in4 Davis Engineers Alluminu Picket Fence vertical members Section Properties 1 1 x 1 x 0.0625" 6061 -T6 Aluminum 1 1 Sx= I I sY= I Fy= 19000 psi E= 10100000 psi Ix Y- centroid l y --► X- centroid f Check bending and Defelction(L/240max) trib(1" oppened).= 0.1 ft W= wind pressure *tit 1.10385 Lb /ft M= 1.25W(L ^2)= 3.449531 Lb -ft 41.39438 Lb -Inch Date 7/29/2010 Job# 2k10 -080 L2= 1.2 0.0931 in3 I 0.1862 in3 15,833.33 psi Sxreq= 0.002614 in 3 OK Ix req= 0.003148 in4 OK safety factor (as per AISC 13th edition) Davis Engineers Alluminu Picket Fence Post Embedments Post section properties Gate Dimentions Post Spaciong Hight of Post(H) Design Toads: Wind Presure a .° Lb /sf % of Solid surface Pwind 334.5 Lb Check For Solid Signs Design Load M(Max(B,L)) 5 ft N(Min(B,L)) 5 ft M /N= 1.00 Net Force Coef. Cf= 1.2 Gust Effect Factor (G)= 0.85 Psolid sign = qz(h)xGxCf Check Post Embedment Load Due To Psolid = Moment Due To Psolid= Allow Lat Soil- Bearing pressure capacity based on 1/3 of emb. Initial Guess For D S1 =2 x SO x 0.333D Footing Width A(d)= (2.34 *P) /(S 1 *B) D(d)= Ft Ft Psf Lb 852.975 Lb -FT Date 7/29/2010 Job# 2k10 -080 H W d h 150 Lb /Ft3 (As per UBC Table 18 -1A) Depht = 0. 5xA( d)x {1 +SQRT[(1 +[(4.36h) /A(d)])]} 349.65 Lb /Ft2 ft 1.14 ft 3.30 ft OK Area 0.4842 in perimeter 8 in X- centroid 1 in Y- centroid 1 in Ix 0.7878 in4 ly 0.7878 in4 Ixy 0.4844 in4 rx 1.2755 in ry 1.2755 in ix -y 0.3032 in4 jx -y 0.3032 in4 Davis Engineers Alluminu Picket Fence Post Section Properties 2 x 2 x 0.0625 6061 -T6 Aluminum 1 Sx= I Fy= 19000 psi E= 10100000 psi Y- centroid ly X- centroid fy Check Bending & Deflection(U240max) M at base of footing= Date 7/29/2010 Job# 2k10 -080 11= 1.2 sarery racror kas per Hrat., 131.11 edition) I 0.7878 in3 I 0.7878 in3 1 15,833.33 psi 852.975 Lbs -ft 10235.7 Lbs -inch Sx Req= 0.65 in3 Ok. Ix Req= 0.405 in4 Ok. Area 0.3594 in perimeter 6 in X- centroid 1 in Y- centroid 0.5 in Ix 0.1518 in4 ly 0.5453 in4 Ixy 0.1797 in4 rx 0.65 in ry 1.2319 in ix -y 0.062 in4 jx -y 0.186 in4 Davis Engineers Alluminu Picket Fence 1 Hotizontal members Section Properties I 1 x 2 x 0.0625" 6061 -T6 Aluminum 1 Fy= 19000 psi E= 10100000 psi Ix Sx= 1Y-centroid -� ly X- centroid fy 0 Check bending and Defelction(L/240max) trib(50% oppened).= 2.5 ft W= wind pressure *trit 27.59625 Lb /ft M= 1.25W(L ^2)= 86.23828 Lb -ft 1034.859 Lb -Inch Date 7/29/2010 Job# 2k10 -080 U= 1.2 I 0.3036 in3 I 0.5453 in3 15,833.33 psi Sxreq= 0.06536 in 3 OK Ix req= 0.15 NG if Ix N.G trial Iy= 0.5453 in4 OK safety factor (as per AISC 13th edition) Area 0.2343 in perimeter 4 in X- centroid 0.5 in Y- centroid 1 in Ix 0.0931 in4 ly 0.0931 in4 Ixy 0.0586 in4 rx 0.6303 in IT 0.6303 in ix -y 0.0344 in4 jx -y 0.0344 in4 Davis Engineers Alluminu Picket Fence vertical members Section Properties I 1 x 1 x 0.0625" 6061 -T6 Aluminum 1 1 Sx= I I sr I Fy= 19000 psi E= 10100000 psi Ix Y- centroid ly X- centroid f M= 1.25W(L ^2)= 3.449531 Lb -ft 41.39438 Lb -Inch Date 7/29/2010 Job# 2k10 -080 U = 1.2 Check bending and Defelction(11240max) trib(1" oppened).= 0.1 ft W= wind pressure *trit 1.10385 Lb /ft I 0.0931 in3 1 I 0.1862 in3 1 15,833.33 psi 1 Sxreq= 0.002614 in 3 OK Ix req= 0.006148 in4 OK safety factor (as per AISC 13th edition) � U 1 Davis Engineers Alluminu Picket Fence Post Embedments Post section properties Gate Dimentions Post Spaciong Hight of Post(H) Design Toads: Wind Presure % of Solid surface Pwind Check For Solid Signs Design Load M(Max(B,L)) N(Min(B,L)) M /N= Net Force Coef. Cf= Gust Effect Factor (G)= Psolid sign = qz(h)xGxCf Check Post Embedment Load Due To Psolid = Moment Due To Psolid= 401.4 Lb 4ft Eft 0.67 1.2 0.85 Ft Ft Lb /sf Psf Lb 818.856 Lb -FT Date 7/29/2010 Job# 2k10 -080 d Allow Lat Soil- Bearing pressure capacity based on 1/3 of emb. 150 Lb /Ft3 (As per UBC Table 18 -1A) Initial Guess For D -5,_ °` De ht = 0.5xA d x 1 +SQRT 1+ 4.36h /A d S1 =2 x SO x 0.333D 324.675 Lb /Ft2 Footing Width ft A(d)= (2.34 *P) /(S1 *B) 0.98 ft D(d)= 3.05 ft OK Area 0.4842 in perimeter 8 in X- centroid 1 in Y- centroid 1 in Ix 0.7878 in4 ly 0.7878 in4 Ixy 0.4844 in4 rx 1.2755 in ry 1.2755 in ix -y 0.3032 in4 jx -y 0.3032 in4 Davis Engineers Alluminu Picket Fence 1 Post Section Properties 2 x 2 x 0.0625 6061 -T6 Aluminum 1 Fy= 19000 psi E= 10100000 psi Ix Sx- Y- centroid -� ly -► X- centroid fy Check Bending & Deflection(L/240max) Sx Req= Date 7/29/2010 Job# 2k10 -080 S1= 1.2 saiery factor tas per miat., IOU] edition) I 0.7878 in3 1 I 0.7878 in3 1 15,833.33 psi M at base of footing= 818.856 Lbs -ft 9826.272 Lbs -inch 0.62 in3 Ok. Ix Req= 0.467 in4 Ok. Area 0.3594 in perimeter 6 in X- centroid 1 in Y- centroid 0.5 in Ix 0.1518 in4 ly 0.5453 in4 Ixy 0.1797 in4 rx 0.65 in ry 1.2319 in ix -y 0.062 in4 jx -y 0.186 in4 Davis Engineers Alluminu Picket Fence Hotizontal members Section Properties 1 1 x 2 x 0.0625" 6061 -T6 Aluminum 1 Fy= 19000 psi E= 10100000 psi I Ix Sx= 1 Y-centroid -10. ly -► X- centroid fy 0 M= 1.25W(L ^2)= -► Check bending and Defelction(L/240max) trib(50% oppened).= 3 ft W= wind pressure *tit 33.1155 Lb /ft 66.231 Lb -ft 794.772 Lb -Inch Date 7/29/2010 Job# 2k10 -080 iZ= 1.2 I 0.3036 in3 1 I 0.5453 in3 1 15,833.33 psi 1 Sxreq= 0.050196 in 3 OK Ix req= 0.09 OK if Ix N.G trial Iy= 0.5453 in4 OK safety factor (as per AISC 13th edition) Area 02343 in perimeter 4 in X- centroid 0.5 in Y- centroid 1 in Ix 0.0931 in4 ly 0.0931 in4 Ixy 0.0586 in4 rx 0.6303 in ry 0.6303 in ix -y 0.0344 in4 jx -y 0.0344 in4 Davis Engineers Alluminu Picket Fence vertical members Section Properties 1 x 1 x 0.0625" 6061 -T6 Aluminum 1 Fy= 19000 psi E= 10100000 psi I Ix Sx= Y- centroid -� i ly X- centroid fy Date 7/29/2010 Job# 2k10 -080 Check bending and Defelction(L/240max) trib(1" oppened).= 0.1 ft W= wind pressure *trit 1.10385 Lb /ft M= 1.25W (L ^2)= 4.967325 Lb -ft 59.6079 Lb -Inch II= 1.2 I 0.0931 in3 I 0.1862 in3 1 15,833.33 psi 1 Sxreq= 0.003765 in 3 OK Ix req= 0.003148 in4 OK safety factor (as per AISC 13th edition) r A, Davis Engineers Alluminu Picket Fence Post Embedments Post . section properties Gate Dimentions Post Spaciong Hight of Post(H) Design Toads: Wind Presure Lb /sf % of Solid surface Pwind 401.4 Lb Check For Solid Signs Design Load M(Max(B,L)) 5 ft N(Min(B,L)) 6 ft M /N= 0.83 Net Force Coef. Cf= 1.2 Gust Effect Factor (G)= 0.85 Psolid sign = qz(h)xGxCf Check Post Embedment Load Due To Psolid = Moment Due To Psolid= Allow Lat Soil- Bearing pressure capacity based on 1/3 of emb. Initial Guess For D S1 =2 x SO x 0.333D Footing Width A(d)= (2.34*P)/(S1 *B) D(d)= Ft Ft Psf Lb 1023.57 Lb -FT Date 7/29/2010 Job# 2k10 -080 H W d h 150 Lb /Ft3 (As per UBC Table 18 -1A) Depht = 0.5xA(d)x {1 +SQRT[(1 +[(4.36h) /A(d)])]} 374.625 Lb /Ft2 ft 1.07 ft 3.31 ft OK Area 0.4842 in perimeter 8 in X- centroid 1 in Y- centroid 1 in Ix 0.7878 in4 ly 0.7878 in4 Ixy 0.4844 in4 rx 1.2755 in ry 1.2755 in ix -y 0.3032 in4 jx -y 0.3032 in4 Jp Davis Engineers Alluminu Picket Fence Post Section Properties 2 x 2 x 0.0625 6061 -T6 Aluminum 1 1 Sx= Fy= 19000 psi E= 10100000 psi Ix _♦ Y- centroid ly X- centroid fy Check Bending & Deflection(U240max) Sx Req= Date 7/29/2010 Job# 2k10 -080 S2= 1.2 safety iacwr has per Hr.7L, I edition) I 0.7878 in3 1 I 0.7878 in3 1 15,833.33 psi 1 M at base of footing= 1023.57 Lbs -ft 12282.84 Lbs -inch 0.78 in3 Ok. Ix Req= 0.584 in4 Ok. Area 0.3594 in perimeter 6 in X- centroid 1 in Y- centroid 0.5 in Ix 0.1518 in4 ly 0.5453 in4 Ixy 0.1797 in4 rx 0.65 in ry 1.2319 in ix -y 0.062 in4 jx -y 0.186 in4 Davis Engineers Alluminu Picket Fence 1 Hotizontal members Section Properties 1 1 x 2 x 0.0625" 6061 -T6 Aluminum i Ix Sx= 1Y-centroid I Fb= Fy= 19000 psi E= 10100000 psi ly _∎ X- centroid fy Q M= 1.25W(L ^2)= 103.4859 Lb -ft 1241.831 Lb -Inch Date 7/29/2010 Job# 2k10 -080 Sl = 1.2 Check bending and Defeiction(L/240max) trib(50% oppened).= 3 ft W= wind pressure *tit 33.1155 Lb /ft I 0.3036 in3 i I 0.5453 in3 i 15,833.33 psi Sxreq= 0.078431 in 3 OK Ix req= 0.18 NG if Ix N.G trial Iy= 0.5453 in4 OK safety factor (as per AISC 13th edition) Area 0.2343 in perimeter 4 in X- centroid 0.5 in Y- centroid 1 in Ix 0.0931 in4 ly 0.0931 in4 Ixy 0.0586 in4 rx 0.6303 in ry 0.6303 in ix -y 0.0344 in4 jx -y 0.0344 in4 Davis Engineers Alluminu Picket Fence vertical members Section Properties 1 x 1 x 0.0625" 6061 -T6 Aluminum 1 Sx= I Fy= 19000 psi E= 10100000 psi Ix Y- centroid ly X- centroid fY Fb= tZ S1= 1.2 Check bending and Defelction(U240max) trib(1" oppened).= 0.1 ft W= wind pressure *tit 1.10385 Lb /ft M= 1.25W(L ^2)= 4.967325 Lb -ft 59.6079 Lb -Inch Date 7/29/2010 Job# 2k10 -080 I 0.0931 in3 1 I 0.1862 in3 15,833.33 psi 1 Sxreq= 0.003765 in 3 OK Ix req= 0.006148 in4 OK safety factor (as per AISC 13th edition) Davis Engineers Alluminu Picket Fence Post Embedments Post section properties Gate Dimentions Post Spaciong Hight of Post(H) Design Toads: Wind Presure at Lb /sf % of Solid surface Pwind 401.4 Lb Check For Solid Signs Design Load M(Max(B,L)) 6 ft N(Min(B,L)) 6 ft M /N= 1.00 Net Force Coef. Cf= 1.2 Gust Effect Factor (G)= 0.85 Allow Lat Soil- Bearing pressure capacity based on 1/3 of emb. Initial Guess For D S1 =2 x SO x 0.333D Footing Width A(d)= (2.34 *P) /(S1 *B) D(d)= Psolid sign= gz(h)xGxCf �x < Psf Check Post Embedment Load Due To Psolid = Lb Moment Due To Psolid= 1228.284 Lb -FT Ft Ft Date 7/29/2010 Job# 2k10 -080 150 Lb /Ft3 (As per UBC Table 18 -1A) Depht = 0.5xA(d)x {1 +SQRT[(1 +[(4.36h) /A(d)])]} 399.6 Lb /Ft2 ft 1.20 ft 3.72 ft OK Area 0.4842 in perimeter 8 in X- centroid 1 in Y- centroid 1 in Ix 0.7878 in4 ly 0.7878 in4 Ixy 0.4844 in4 rx 1.2755 in ry 1.2755 in ix -y 0.3032 in4 jx -y 0.3032 in4 Davis Engineers Alluminu Picket Fence Post Section Properties 1 2 x 2 x 0.0625 6061 -T6 Aluminum 1 I Fb= Fy= 19000 psi E= 10100000 psi Ix Y- centroid ly -► X- centroid fy Check Bending & Deflection(L/240max) Sx Req= Date 7/29/2010 Job# 2k10 -080 SZ= 1.2 saiery iac ur tab per HIOL• 13u1 edition) I 0.7878 in3 I 0.7878 in3 1 15,833.33 psi M at base of footing= 1228.284 Lbs -ft 14739.408 Lbs -inch 0.93 in3 NG Ix Req= 0.700 in4 Ok. e0) Area 0.3594 in perimeter 6 in X- centroid 1 in Y- centroid 0.5 in Ix 0.1518 in4 ly 0.5453 in4 Ixy 0.1797 in4 rx 0.65 in ry 1.2319 in ix -y 0.062 in4 jx -y 0.186 in4 j 1 j Davis Engineers Alluminu Picket Fence Hotizontal members Section Properties I 1 x 2 x 0.0625" 6061 -T6 Aluminum 1 Fy= 19000 psi E= 10100000 psi Ix Y- centroid ly X- centroid ty 0 M= 1.25W(LA2)= 149.0198 Lb -ft 1788.237 Lb -Inch Date 7/29/2010 Job# 2k10 -080 U= 1.2 Check bending and Defelction(L/240max) trib(50% oppened).= 3 ft W= wind pressure *tit 33.1155 Lb /ft I 0.3036 in3 I 0.5453 in3 1 15,833.33 psi Sxreq= 0.112941 in 3 OK Ix req= 0.32 NG if Ix N.G trial Iy= 0.5453 in4 OK safety factor (as per AISC 13th edition) Area 0.2343 in perimeter 4 in X- centroid 0.5 in Y- centroid 1 in Ix 0.0931 in4 ly 0.0931 in4 Ixy 0.0586 in4 rx 0.6303 in ry 0.6303 in ix -y 0.0344 in4 jx -y 0.0344 in4 Davis Engineers Alluminu Picket Fence vertical members Section Properties I 1 x 1 x 0.0625" 6061 -T6 Aluminum 1 I s x= I Fy= 19000 psi E= 10100000 psi Ix __� Y- centroid ly fy Q -► Date 7/29/2010 Job# 2k10 -080 M= 1.25W(L ^2)= 4.967325 Lb -ft 59.6079 Lb -Inch S2= 1.2 Check bending and Defelction(U240max) trib(1" oppened).= 0.1 ft W= wind pressure *tit 1.10385 Lb /ft I 0.0931 in3 1 I 0.1862 in3 1 15,833.33 psi i Sxreq= 0.003765 in 3 OK Ix req= 0.010623 in4 OK safety factor (as per AISC 13th edition) t N 1 ' 1/16' Area: 03594 sq in Perimeter: 11.6246 in Bounding box: X: 0.0000 -- 1.0000 in Y: 0.0000 -- 2.0000 in Centroid: X: 0.5000 in Y: 1.0000 in Moments of inertia: X: 0.5454 sq in sq in Y: 0.1518 sq in sq in Product of inertia: XY: 0.1197 sq in sq in Radii of gyration: X: 12319 in Y: 0 .6500 in Principal moments (sq in sq in) and X -Y directions about centroid: I: 0.0620 along 3 440.0000 1.00001' J: 0.1860 along 3 4-L0000 0.00001 k r 1/16' Area: 02343 sq in Perimeter: 16216 in Bounding box: X: 0.0000 -- 1.0000 in Y: 0.0000 -- 1.0000 in Gentroid: X: 0.4998 in Y: 05002 in Moments of inertia: X: 0.0931 sq in scr in Y: 0.0930 sq in sq in Product of inertia: XY: 0.0586 ad in sci in Radii of gyration: X: 0.6303 in Y: 0.6300 in Principal moments (sq in sq in) and X -Y directions about centroid: I: 0.0344 along 3 /40.1139 0b333va J: 0.0345 along 3 4- 0.6333 0.11391/a v 1 1/16 Area: 03594 sq in Perimeter: 11.6246 in Bounding box: X: 0.0000 -- 2.0000 in Y: 0.0000 -- 1.0000 in Centroid: X: 1.0000 in Y: 05000 in Moments of inertia: X: 0.1518 sq in sq in Y: 05453 sq in sq in Product of inertia: XY: 0.1197 sq in sq in Radi1 of' gyration: X: 0 .6500 in Y: 12319 in Principal moments (sq in sq in) and X -Y directions about centroid: 1: 0.0620 along 3 41.0000 0.00001/2 J: 0.1860 along 3 40.0000 L00001/2 'A' (Spacing) (FT) 'H' (Height) (FT) (N Ci-i) VERTICAL POST . TOP < BOTTOM RAILS CONCRETE FOOTING 0 (INCH) 'D' (Depth) (FT) Size Thickness Size Thickness 4' -0' 4' -0; 4' 2'x2' 0.0625' 2'xl' 0.0625' 12' 3' -0' 5' -0' 2'x2' 0 .0625' 2'x1' 0.0625' 12' 3' -6' 6' -0' 2'x2' 0 .0625' 2'x1' 0.0625' 12' 3' -8' 4' -0' 5' -0' 5' 2'x2' 0.0625' 2'x1' 0.0625' 12' 3' -6' 5' -0' 2'x2' 0 .0625' 2'x1' 0.0625' 12' 3' -6' 6' - 2'x2' 0.0625' 2'xl' 0.0625' 12' 3' -3' 4' -0' 6' - • • 6' • • • 2'x2' 0.0625' 2 °xl' 0.0625' 12' 3' -6' 5 • • • w J d 1-- w ILI 0 z N w j VERT. POST ALUM. TUBE (SEE TABLE) n II 0 (E TAB E) ALUM. CAST BRACKET W/ (2) "10x1 TO POST AND (1) "10x1' TO 1-IORIZ RAILS TYPICAL. 'A' 4' o.c. MAX. 4' o.c. M,4X. n n TOP VIEW 3/4'=I'-0' I FOR CONC FOOTING DIAM (SEE TABLE) (POST SPACING, SEE TABLE) FRONT VIEW 3/4'.1'-0' VERT. PICKET I'xl'x0.062 ALUM. TUBE TYP. n n n n n n --- - - - - -- MARK TOP RAIL ALUM. TUBE (SEE TABLE) L 0 CS� E TAI3 E) REVISION DESCRIPTION w — VERT. POST 3/4"01'-0' TOP RAIL ALUM. TUBE (SEE TABLE) VERT. PICKET l'xl'x0.062 ALUM. TUBE ® 4' o.c. ALUM. TUBE (SEE TABLE) -- 8oTTOM RAIL ALUM. TUBE (SEE TABLE) FOR CONCRETE FOOTING DIAMETER (SEE TABLE) DATE • • • •• •• • • • • • • • •• •• • ••• • • • • • • • ••• • • I. ALL ALUMINUM SHALL BE TYPE 6061 -Tb, UNLESS NOTED OTHERWISE (U.N.0) 2. BOLTS d OTHER FASTENERS DIRECTLY IN CONTACT WITH ALUMINUM MEMBERS SHALL BE ALUMINUM, STAINLESS STEEL OR ELECTRIC) GALVANIZED STEEL. DOUBLE CADMIUM PLATED STEEL BOLTS MAY BE ALLOWED UPON WRITTEN REQUEST TO THE ENGINEER OF RECORD. 3. ALUMINUM PARTS SHALL BE WELDED WITH AN INERT -GAS SHIELDED ARC OR RESISTANCE WELDING PROCESS. FLUX WELDING 15 NOT ALLOWED. FILLER ALLOYS SHALL BE AS AMERICAN WELDING SOCIETY SPECIFICATIONS A5.10 -6 ALL WELDING SHALL BE PERFORMED 5Y CERTIFIED WELDERS. 4. DURING ERECTION, ALUMINUM STRUCTURES SHALL. BE ADEQUATELY BRACED AND FASTENED TO RESIST DEAD, WIND AND ERECTION LDADS. 5. ALUMINUM IN CONTACT WITH NON - COMPATIBLE METALS SUCH AS STEEL SHALL. BE PROTECTED AS PER MSC 2003.6.4.2. 6. ALUMINUM IN CONTACT WITH CONCRETE SHALL BE PROTECTED WITH AN ALKALI RESISTANT COATING. 1. ALUMINUM IN CONTACT WITH W0017 SHALL BE PROTECTED WITH TWO COATS OF ALUMINUM METAL- AND - MASONRY PAINT. 6. ALUM I NUM RA I J I NG NOTES : ALL GONEGTIONS TO BE WELDED. USE s/b" MINIMUM WELD SIZE, TYPICAL U.N.O. CONCRETE NOTES: I. ALL CONCRETE SHALL ATTAIN A MINIMUM COMPRESSIVE STRENGTH OF 3000PSI. 2. AGREGATES TO BE GLEAN AND WELL GRADED. MAXIMUM SIZE TO BE I ". 3. CONCRETE SLUMP TO BE 3" MINIMUM TO 5" MAXIMUM. SOIL STATtMENT I. THE SOIL 13 ASSUMED TO CONSIST OF UNDISTURBED SAND AND ROCK WITH AN ALLOWABLE BEARING CAPACITY OF 2.0 KSF. SHOULD OTHER CONDITIONS BE ENCOUNTERED, CONTACT THE ENGINEER BEFORE PROCEEDING WITH THE WORK. AT THE TIME OF CONSTRUCTION, A LETTER ATTESTING THAT CONDITIONS ARE SIMILAR TO THOSE UPON WHICH THE DESIGN 15 BASED WILL BE SUBMITTED TO THE BUILDING OFFICIAL. •;O� ;� old 121361 • E.B. No 0001809 DAVIS ENGINEERS 3801A11tAl`rI• CANAL ROAD • : 33144 • ` (30 ' ) .266-2566 Uqp•NG ••• • ••• • DATE: . t2)1 -21-2010 SCALE: AS-SHOWN SHOP DRAWINGS ALUMINUM PICKET FENCE ISLAND FENCE OF DADS (305) SSS -9090 DRAW E.M. HAROLD GOBS P.E. CIVIL ENGINEER P E. No.10,193 PROJECT: CLIENT: DE No.: Description: DATE: No. of Pages: DAVIS ENGINEERS 780 TAMIAMI CANAL ROAD — MIAMI, FLORIDA 33144 PHONE: 305 - 266 -2566 FAX: 305 - 267 -1556 E -mail: projects c davisengrs.com Island Fence Island Fence 2K10 -080 Structural Calculations Aluminum Single Gate September 15, 2010 Cover + 32 Pag R: \DE PROJECT CORRESPONDENCE \0 -DE Project Correspondance \2K10000 \2K10 -080 - 20100915 - COV -Island Fence.doc O.L. #:127365 E.B. #: 0001809 � r`Lfbi o Harold R. Cobb, P.E. Structural Engineer FL. No.: 10993 DAVIS ENGINEERS 780 TAMIAMI CANAL ROAD - MIAMI, FLORIDA 33144 PHONE: 305 - 266 -2566 FAX: 305 - 267 -1556 E -mail: projects@davisengrs.com o.L. #:127365 E.B. #: 0001809 I Codes Materials: (1) FBC — 2007 (2) ACI — 318/05 (3) ASCE 7 -05 (4) AISC — ASD (13th Ed.) (5) ACI — 530/05 (6) NDS — 1997 (7) NCMA -1997 (1) Concrete, f c = 3,000 psi (U.O.N.) (2) Reinforcing Steel, fy = 60,000 psi — ASTM A 615, Grade 60 (U.O.N.) (3) Structural Steel, Fy = 50,000 psi — ASTM A 572, Grade 50 (U.O.N.) (4) Steel Tube, Fy = 42,000 psi — ASTM A 500 Grade B (U.O.N.) (5) Steel Pipe, Fy = 35,000 psi — ASTM A53 Grade E (U.N.O.) (6) Masonry, f = 1,500 psi (U.N.O.) (7) Aluminum, AL- 6061 -T6 (U.N.O.) (8) Wood, Fb = 1,200 psi (U.N.O.) (9) Anchor Rods, ASTM A 307 (U.N.0) (10) Bolting Materials, ASTM A 3250 or A 490 (U.N.O.) Table of Content: Page Description 1 4' High Gate 4 5' High Gate 7 6' High Gate Notes: If you have any questions, please call us at 305 - 266 -2566 . DAVIS ENGINEERS 780 TAMIAMI CANAL ROAD - MIAMI, FLORIDA 33144 PHONE: 305 - 266 -2566 FAX: 305- 267 -1556 E -mail: projects@davisengrs.com O.L. #:127365 E.B. #: 0001809 GENERAL NOTES: PEDESTRIAN RAIUNG DESIGN CRITERIA: 1. ALL WORK SHALL CONFORM TO FLORIDA BUILDING CODE 2007 2. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS IN THE FIELD PRIOR TO START OF WORK AND NOTIFY ARCHITECT/ENGINEER OF ANY DISCREPANCY IN THE DRAWINGS AND OBTAIN HIS APPROVAL BEFORE PROCEEDING WITH WORK. 3. THIS WORK REQUIRES A BUILDING PERMIT. DO NOT BEGIN WORKING UNTIL A BUILDING PERMIT IS OBTAINED. 4. CONTRACTOR TO FURNISH ALL LABOR, MATERIALS, SERVICES AND EQUIPMENT NECESSARY TO COMPLETE ALL WORK SHOWN ON THE DRAWINGS AND SPECIFIED HEREIN. 5. DO NOT SCALE DRAWINGS, DIMENSIONS GOVERN. 6. ENGINEER'S VISITS TO THE SITE DURING CONSTRUCTION SHALL BE SCHEDULED WITHIN 24 HOURS IN ADVANCE PRIOR TO INSPECTION. 7. THE CONTRACTOR SHALL NOT PROCEED WITH ANY ADDITIONAL SERVICES OR WORK WITHOUT PRIOR NOTIFICATION TO THE OWNER, FOLLOWED BY A CHANGE ORDER. 8. THE CONTRACTOR SHALL MAKE REQUIRED ARRANGEMENTS, SECURE AND PAY FOR ALL , BARRICADES, ENCLOSURES, AND FENCING AS NEEDED FOR AND DURING THE PROGRESS TO PROTECT ADJACENT PROPERTIES. 9. DO NOT SUBSTITUTE MATERIALS, EQUIPMENTS OR METHODS OF CONSTRUCTION UNLESS SUCH SUBSTITUTIONS OR CHANGES HAVE BEEN APPROVED IN WRITING BY THE OWNER/ENGINEER. 10. CONTRACTOR SHALL MAINTAIN AN ACCURATE RECORD OF CHANGE ORDERS AND VARIATIONS THROUGHOUT THE PROGRESS OF THE WORK. USE ONE SET OF DOCUMENTS EXCLUSIVELY FOR THIS JOB. 11. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR MEANS AND METHODS OF CONSTRUCTION, AND FOR THE SEQUENCES AND PROCEDURES TO BE USED. 1. LOADS AT THE TOP RAILINGS AND HANDRAILS: UNIFORM LOAD OF w EQUAL AND UP AND TOP RAILING AND DIRECTION AT THE TO 200 LBS AT THE IN AND OUT IN THE VERTICAL DIRECTION, AT THE SAME TIME, AND CONCENTRATED UNIFORM LOAD OF w IN AN IN AND OUT VERTICAL DIRECTION A HORIZONTAL AND LOAD OF P AND BRACKET AT RESPECTIVELY AND IN AN UP AND AND VERTICAL CRITICAL THE ASSUMED TO NOT RAIL AND BETWEEN TO 500 ACTING IN AND OUT IN THE HORIZONTAL DIRECTION, DOWN IN THE VERTICAL DIRECTION ALONG THE HANDRAIL, BUT NOT IN A HORIZONTAL AND VERTICAL SAME TIME; OR A CONCENTRATED LOAD OF P EQUAL MIDSPAN OF THE TOP RAILING AND HANDRAIL ACTING HORIZONTAL DIRECTION, AND UP AND DOWN IN THE BUT NOT IN A HORIZONTAL AND VERTICAL DIRECTION WHICHEVER IS MOST CRITICAL. THE UNIFORM LOAD LOAD SHALL BE ASSUMED TO NOT ACT AT THE SAME TIME. 2. LOADS AT POSTS AND AT BRACKETS AT HANDRAILS: EQUAL TO 50 POUNDS PER LINEAL FOOT ACTING HORIZONTAL DIRECTION AND IN AN UP AND DOWN ALONG THE TOP RAILING AND HANDRAIL, BUT NOT IN VERTICAL DIRECTION AT THE SAME TIME OR A CONCENTRATED EQUAL TO 200 POUNDS AT THE TOP OF THE TOP RAILING THE HANDRAIL AT THE POST AND HANDRAIL BRACKET, ACTING IN AN IN AND OUT HORIZONTAL DIRECTION DOWN VERTICAL DIRECTION, BUT NOT IN A HORIZONTAL DIRECTION AT THE SAME TIME, WHICHEVER IS MOST UNIFORM LOAD AND CONCENTRATED LOAD SHALL BE ACT AT THE SAME TIME. 3. LOADS AT ALL MEMBERS LOCATED BELOW THE TOP THE POSTS: UNIFORM LOAD OF w EQUAL TO 25 POUNDS PER SQUARE FOOT R OCCUPANCIES ACTING IN AN IN AND OUT HORIZONTAL DIRECTION. 4. SAFEGUARDS IN AND AROUND BUILDINGS OF GROUP SHALL PROVIDE PROTECTION FOR CHILDREN BY PROVIDING ADDITIONAL RAILS, VERTICAL PICKETS OR AN ORNAMENTAL FILLER BELOW THE TOP RAIL WHICH WILL REJECT A 4° DIAMETER OBJECT; PERMITTING, HOWEVER, SUCH ORNAMENTAL FILLERS TO HAVE INDIVIDUAL OPENINGS NOT EXCEEDING 64 SO. INCHES IN AREA. 5. THE MAXIMUM CLEARANCE BETWEEN THE BOTTOM RAIL AND THE ADJACENT SURFACE SHALL NOT EXCEED 2', THE 2' CLEARANCE SHALL BE MEASURED FROM THE BOTTOM RAIL OF THE BALUSTRADE TO A LINE PASSING THROUGH THE TREAD NOSINGS. STEEL RAILING NOTES: ALUMINUM RAILING NOTES: OTHERWISE (U.N.0.) WITH ALUMINUM OR ELECTRO BOLTS MAY BE OF RECORD. -GAS SHIELDED ARC IS NOT ALLOWED. SPECIFICATIONS WELDERS. BE ADEQUATELY LOADS. SUCH AS STEEL WITH AN WITH TWO WELD SIZE, TYPICAL 1. ALL STRUCTURAL STEEL SHALL BE ASTM A36 (U.N.0.) 2. ALL SHOP CONNECTIONS TO BE MADE WITH ASTM A325 BOLTS OR WELDED USING E70 ELECTRODES AND SHALL CONFORM TO THE SPECIFICATIONS SET FORTH IN THE AWS STRUCTURAL WELDING CODE. 3. STRUCTURAL STEEL SHALL RECEIVE ONE COAT SHOP PAINT AND RE -TOUCH AFTER ERECTION. 4. STRUCTURAL TUBE SHALL BE ASTM A 500 GRADE B. 5. STRUCTURAALL WELDING SHALL BE PERFORMED BY CERTIFIED WELDERS PER AWS 'STANDARD QUALIFICATIONS PROCEDURE° TO PERFORM TYPE OF WORK REQUIRED. ALL WELDING SHALL BE IN ACCORDANCE WITH AWS WELDING CODE. 6. STEEL STAIR AND RAILING SYSTEMS USED IN EXTERIOR APPLICATIONS AND /OR EXPOSED TO ADVERSE CONDITIONS MUST BE PROPERLY AND REGULARY MAINTAINED TO MINIMIZE CORROSION CAN RESULT IN EVENTUAL STRUCTURAL FAILURE. 7. ALL CONNECTIONS TO BE WELDED USE 3/16' MIN. WELD SIZE, TYPICAL U.N.OL PIPE SHALL BE ASTM A 53 TYPE E. GRADE B. 1. ALL ALUMINUM SHALL BE TYPE 6061 -T6, UNLESS NOTED 2. BOLTS & OTHER FASTENERS DIRECTLY IN CONTACT MEMBERS SHALL BE ALUMINUM, STAINLESS STEEL GALVANIZED STEEL DOUBLE CADMIUM PLATED STEEL ALLOWED UPON WRITTEN REQUEST TO THE ENGINEER 3. ALUMINUM PARTS SHALL BE WELDED WITH AN INERT OR RESISTANCE WELDING PROCESS. FLUX WELDING FILLER ALLOYS SHALL BE AS AMERICAN WELDING SOCIETY A5.10 -69. ALL WELDING SHALL BE PERFORMED BY CERTIFIED 4. DURING ERECTION, ALUMINUM STRUCTURES SHALL BRACED AND FASTENED TO RESIST DEAD, WIND AND ERECTION 5. ALUMINUM IN CONTACT WITH NON- COMPATIBLE METALS SHALL BE PROTECTED AS PER FBC 2003.8.4.2. 6. ALUMINUM IN CONTACT WITH CONCRETE SHALL BE PROTECTED ALKALI RESISTANT COATING. 7. ALUMINUM IN CONTACT WITH WOOD SHALL BE PROTECTED COATS OF ALUMINUM METAL - AND - MASONRY PAINT. 8. ALL CONECTIONS TO BE WELDED. USE 3/16' MINIMUM U.N.O. Davis Engineers Post Embedments Post section properties Gate Dimentions Post Spaciong Hight of Post(H) Psolid sign = qz(h)xGxCf Check Post Embedment Load Due To Psolid = Moment Due To Psolid= Allow Lat Soil- Bearing pressure capacity based on 1/3 of emb. Initial Guess For D S1=2 x SO x 0.333D Footing Width A(d)= (2.34 *P) /(S 1 *B) D(d)= Design Toads: Wind Presure Lb /sf % of Solid surface Pwind 267.6 Lb Check For Solid Signs Design Load M(Max(B,L)) 4 ft N(Min(B,L)) 4 ft M /N= 1.00 Net Force Coef. Cf= 1.2 Gust Effect Factor (G)= 0.85 Lb 545.904 Lb -FT Ft Ft Psf Date 8/3/2010 Job# 2k10 -080 H W d h 150 Lb /Ft3 (As per UBC Table 18 -1A) Depht = 0. 5xA( d)x {1 +SQRT[(1 +[(4.36h) /A(d)])]} 299.7 Lb /Ft2 ft 1.07 ft 2.82 ft OK Area 0.4842 in perimeter 8 in X- centroid 1 in Y- centroid 1 in Ix 0.7878 in4 ly 0.7878 in4 Ixy 0.4844 in4 rx 1.2755 in ry 1.2755 in ix -y 0.3032 in4 jx -y 0.3032 in4 Davis Engineers Post Section Properties 2 x 2 x 0.065 6061 -T6 Alum I S Y= ly X- centroid -� Fy= 19000 psi E= 10100000 psi Y- centroid fy Check Bending & Deflection(L/240max) Sx Req= Date 8/3/2010 Job# 2k10 -080 12= 1.2 sait;ty idawr kids pet H1ot, 13111 edition) I 0.7878 in3 1 I 0.7878 in3 1 15,833.33 psi M at base of footing = 545.904 Lbs -ft 6550.848 Lbs -inch 0.41 in3 Ok. Ix Req= 0.208 in4 Ok. Area 0.3594 in perimeter 6 in X- centroid 1 in Y- centroid 0.5 in Ix 0.1518 in4 ly 0.5453 in4 Ixy 0.1797 in4 rx 0.65 in ry 1.2319 in ix -y 0.062 in4 jx -y 0.186 in4 , f Davis Engineers Hotizontal members Section Properties 2 x 1 x 0.065 6061 -T6 Alum 1 Sx= I sr I Fy= 36000 psi E= 29000000 psi Ix Y- centroid ly ► X- centroid fY Check bending and Defelction(L1240max) trib(70% oppened).= 2 ft W= wind pressure *tit 44.154 Lb /ft M= 1.25W(L ^2)= -► 22.077 Lb -ft 264.924 Lb -Inch Date 8/3/2010 Job# 2k10 -080 S1= 1.2 I 0.3036 in3 0.5453 in3 1 (30,000.00 psi 1 Sxreq= 0.008831 in 3 OK Ix req= 0.01 in4 OK if Ix N.G trial Iy= 0.5453 in4 OK safety factor (as per AISC 13th edition) 3 � r Area 02343 in perimeter 4 in X- centroid 0.5 in Y- centroid 1 in Ix 0.0931 in4 ly 0.0931 in4 Ixy 0.0586 in4 rx 0.6303 in ry 0.6303 in ix -y 0.0344 in4 jx -y 0.0344 in4 Davis Engineers Hotizontal members Section Properties 1 1 x 1 x 0.065 6061 -T6 Alum 1 Fy= 36000 psi E= 29000000 psi 1 1 Sx= Sy= Ix Y- centroid ly X- centroid fy M= 1.25W(L ^2)= 22.077 Lb -ft 264.924 Lb -Inch Check bending and Defelction(L/240max) trib(50% oppened).= 2 ft W= wind pressure *tit 44.154 Lb /ft Ix req= 0.01 Date 8/3/2010 Job# 2k10 -080 S1= 1.2 I 0.0931 in3 I 0.1862 in3 1 30,000.00 psi 1 Sxreq= 0.008831 in 3 OK OK safety factor (as per AISC 13th edition) 1 k Davis Engineers Post Embedments Post section properties Gate Dimentions Post Spaciong Hight of Post(H) Design Toads: Wind Presure .% of Solid surface Pwind Check For Solid Signs Design Load M(Max(B,L)) N(Min(B,L)) M /N= Net Force Coef. Cf= Gust Effect Factor (G)= Psolid sign = qz(h)xGxCf Check Post Embedment Load Due To Psolid = Moment Due To Psolid= Allow Lat Soil- Bearing pressure capacity based on 1/3 of emb. Initial Guess For D S1 =2 x SO x 0.333D Footing Width A(d)= (2.34 *P) /(S1 *B) D(d)= 267.6 Lb 5 ft 4 ft 1.25 1.2 0.85 ft- Lb 682.38 Lb -FT 150 Lb /Ft3 (As per UBC Table 18 -1A) Depht = 0.5xA(d)x {1 +SQRT[(1 +[(4.36h) /A(d)])]} 349.65 Lb /Ft2 ft Ft Ft Psf Lb /sf 1.14 ft 3.02 ft OK Date 8/3/2010 Job# 2k10 -080 Area 0.4842 in perimeter 8 in X- centroid 1 in Y- centroid 1 in Ix 0.7878 in4 ly 0.7878 in4 Ixy 0.4844 in4 rx 1.2755 in ry 1.2755 in ix -y 0.3032 in4 jx -y 0.3032 in4 Davis Engineers Post Section Properties 2 x 2 x 0.065 6061 -T6 Alum I Sy= I Fy= 19000 psi E= 10100000 psi Ix Y- centroid l y - --► X- centroid fy Check Bending & Deflection(L/240max) M at base of footing= Sx Req= Date 8/3/2010 Job# 2k10 -080 i1= 1.2 sa tery iaaur kas per HIOL. i edition) 0.7878 in3 1 I 0.7878 in3 I 15,83333 psi 682.38 Lbs -ft 8188.56 Lbs -inch 0.52 in3 Ok. Ix Req= 0.259 in4 Ok. Area 0.3594 in perimeter 6 in X- centroid 1 in Y- centroid 0.5 in Ix 0.1518 in4 ly 0.5453 in4 Ixy 0.1797 in4 rx 0.65 in ry 1.2319 in ix -y 0.062 in4 jx -y 0.186 in4 Davis Engineers Hotizontal members Section Properties 1 2 x 1 x 0.065 6061 -T6 Alum 1 Fy= 36000 psi E= 29000000 psi I Ix Sx= Y- centroid ly ► X- centroid fy M= 1.25W(L ^2)= 34.49531 Lb -ft 413.9438 Lb -Inch Date 8/3/2010 Job# 2k10 -080 12= 1.2 Check bending and Defelction(U240max) trib(70% oppened).= 2 ft W= wind pressure *tit 44.154 Lb /ft 1 0.3036 in3 i I 0.5453 in3 i 1 30,000.00 psi 1 Sxreq= 0.013798 in 3 OK Ix req= 0.01 in4 OK if Ix N.G trial Iy= 0.5453 in4 OK safety factor (as per AISC 13th edition) Area 0.2343 in perimeter 4 in X- centroid 0.5 in Y- centroid 1 in Ix 0.0931 in4 ly 0.0931 in4 Ixy 0.0586 in4 rx 0.6303 in ry 0.6303 in ix -y 0.0344 in4 jx -y 0.0344 in4 Davis Engineers Hotizontal members Section Properties 1 x 1 x 0.065 6061 -T6 Alum 1 Fy= 36000 psi E= 29000000 psi Ix Y- centroid ly X- centroid fy M= 1.25W(L "2)= 34.49531 Lb -ft 413.9438 Lb -Inch Check bending and Defelction(L/240max) trib(50% oppened).= 2 ft W= wind pressure *tit 44.154 Lb /ft Ix req= 0.01 Date 8/3/2010 Job# 2k10 -080 S2= 1.2 I 0.0931 in3 1 I 0.1862 in3 1 1 30,000.00 psi Sxreq= 0.013798 in 3 OK OK safety factor (as per AISC 13th edition) Davis Engineers Post Embedments Post section properties Gate Dimentions Post Spaciong Hight of Post(H) Design Toads: Wind Presure % of Solid surface Pwind Check For Solid Signs Design Load M(Max(B,L)) N(Min(B,L)) M /N= Net Force Coef. Cf= Gust Effect Factor (G)= Psolid sign = qz(h)xGxCf Check Post Embedment Load Due To Psolid = Moment Due To Psolid= Ft Ft 267.6 Lb 6ft 4 ft 1.50 1.2 0.85 Lb /sf Psf Lb 818.856 Lb -FT Date 8/3/2010 Job# 2k10 -080 Allow Lat Soil- Bearing pressure capacity based on 1/3 of emb. 150 Lb /Ft3 (As per UBC Table 18 -1A) Initial Guess For D Depht = 0. 5xA( d)x {1 +SQRT[(1 +[(4.36h) /A(d)])]} S1 =2 x SO x 0.333D 366.3333 Lb /Ft2 Footing Width ft A(d)= (2.34 *P) /(S1 *B) 1.31 ft D(d)= 3.46 ft OK Area 0.4842 in perimeter 8 in X- centroid 1 in Y- centroid 1 in Ix 0.7878 in4 ly 0.7878 in4 Ixy 0.4844 in4 rx 1.2755 in ry 1.2755 in ix -y 0.3032 in4 jx -y 0.3032 in4 Davis Engineers Post Section Properties 2 x 2 x 0.065 6061-T6 Alum 1 1 Sx— I I sY= I Fy= 19000 psi E= 10100000 psi Ix __ Y- centroid ly —� X- centroid fy Check Bending & Deflection(L/240max) Sx Req= Date 8/3/2010 Job# 2k10 -080 S1= 1.2 sale y iaetor t as per ■10l, i .3u1 edition) I 0.7878 in3 I 0.7878 in3 15,833.33 psi 1 M at base of footing= 818.856 Lbs -ft 9826.272 Lbs -inch 0.62 in3 Ok. Ix Req= 0.311 in4 Ok. Area 0.3594 in perimeter 6 in X- centroid 1 in Y- centroid 0.5 in Ix 0.1518 in4 ly 0.5453 in4 Ixy 0.1797 in4 rx 0.65 in ry 1.2319 in ix -y 0.062 in4 jx -y 0.186 in4 Davis Engineers Hotizontal members Section Properties 2 x 1 x 0.065 6061 -T6 Alum 1 Sx= I Fy= 36000 psi E= 29000000 psi fy 0 Check bending and Defelction(11240max) 2ft W= wind pressure *trit 44.154 Lb /ft trib(70% oppened).= Ix Y- centroid ly X- centroid M= 1.25W(L ^2)= 49.67325 Lb -ft 596.079 Lb -Inch Date 8/3/2010 Job# 2k10 -080 i1= 1.2 I 0.3036 in3 1 I 0.5453 in3 1 30,000.00 psi 1 Sxreq= 0.019869 in 3 OK Ix req= 0.02 in4 OK if Ix N.G trial ly= 0.5453 in4 OK safety factor (as per AISC 13th edition) Area 0.2343 in perimeter 4 in X- centroid 0.5 in Y- centroid 1 in Ix 0.0931 in4 ly 0.0931 in4 Ixy 0.0586 in4 rx 0.6303 in ry 0.6303 in ix -y 0.0344 in4 jx -y 0.0344 in4 Davis Engineers Hotizontal members Section Properties i 1 x 1 x 0.065 6061 -T6 Alum 1 I sY= I Fy= 36000 psi E= 29000000 psi ly _� X- centroid fy 0 Date 8/3/2010 Job# 2k10 -080 Check bending and Defelction(LJ240max) trib(50% oppened).= 2 ft W= wind pressure *trit 44.154 Lb /ft M= 1.25W(L ^2)= 49.67325 Lb -ft 596.079 Lb -Inch Ix req= 0.02 Sl= 1.2 I 0.0931 in3 i I 0.1862 in3 1 30,000.00 psi Sxreq= 0.019869 in 3 OK OK safety factor (as per AISC 13th edition) Davis Engineers Post Embedments Post section properties Gate Dimentions Post Spaciong Hight of Post(H) Design Toads: Wind Presure of Solid surface Pwind Check For Solid Signs Design Load M(Max(B,L)) N(Min(B,L)) M /N= Net Force Coef. Cf= Gust Effect Factor (G)= Psolid sign = qz(h)xGxCf Check Post Embedment Load Due To Psolid = Moment Due To Psolid= Allow Lat Soil- Bearing pressure capacity based on 1/3 of emb. Initial Guess For D S1 =2x SO x 0.333D Footing Width A(d)= (2.34 *P) /(S1 *B) D(d)= Ft Ft 334.5 Lb O ft 5 ft 0.80 1.2 0.85 Lb 682.38 Lb -FT 150 Lb /Ft3 (As per UBC Table 18 -1A) Depht = 0.5xA(d)x {1 +SQRT[(1 +[(4.36h) /A(d)])]} 324.675 Lb /Ft2 ft 0.98 ft 2.84 ft OK Lb /sf Psf Date 8/3/2010 Job# 2k10 -080 Area 0.4842 in perimeter 8 in X- centroid 1 in Y- centroid 1 in Ix 0.7878 in4 ly 0.7878 in4 Ixy 0.4844 in4 rx 1.2755 in ry 1.2755 in ix -y 0.3032 in4 jx -y 0.3032 in4 Davis Engineers Post Section Properties 2 x 2 x 0.065 6061 -T6 Alum 1 l I Fb= Fy= 19000 psi E= 10100000 psi Ix Y- centroid l y X- centroid fy Check Bending & Deflection(L/240max) M at base of footing= Sx Req= Date 8/3/2010 Job# 2k10 -080 Sl= 1.2 eatery [actor tas per HUM., [Jtr[ edition) I 0.7878 in3 I 0.7878 in3 1 I 15,833.33 psi 1 682.38 Lbs -ft 8188.56 Lbs -inch 0.52 in3 Ok. Ix Req= 0.324 in4 Ok. Area 0.3594 in perimeter 6 in X- centroid 1 in Y- centroid 0.5 in Ix 0.1518 in4 ly 0.5453 in4 Ixy 0.1797 in4 rx 0.65 in ry 1.2319 in ix -y 0.062 in4 jx -y 0.186 in4 Davis Engineers Hotizontal members Section Properties 1 2 x 1 x 0.065 6061 -T6 Alum I sY= I Fy= 36000 psi E= 29000000 psi Ix Y- centroid ly X- centroid fy M= 1.25W(L ^2)= 27.59625 Lb -ft 331.155 Lb -Inch Date 8/3/2010 Job# 2k10 -080 U= 1.2 Check bending and Defelction(L/240max) trib(70% oppened).= 2.5 ft W= wind pressure *tit 55.1925 Lb /ft I 0.3036 in3 i I 0.5453 in3 30,000.00 psi Sxreq= 0.011039 in 3 OK Ix req= 0.01 in4 OK if Ix N.G trial ly= 0.5453 in4 OK safety factor (as per AISC 13th edition) Area 02343 in perimeter 4 in X- centroid 0.5 in Y- centroid 1 in Ix 0.0931 in4 ly 0.0931 in4 Ixy 0.0586 in4 rx 0.6303 in ry 0.6303 in ix -y 0.0344 in4 jx -y 0.0344 in4 Davis Engineers Hotizontal members Section Properties 1 x 1 x 0.065 6061 -T6 Alum I Fb= Fy= 36000 psi E= 29000000 psi Ix Sx= Y- centroid -� ly X- centroid fy Check bending and Defelction(L/240max) trib(50% oppened).= 2.5 ft W= wind pressure *trit 55.1925 Lb /ft M= 1.25W(L ^2)= 27.59625 Lb -ft 331.155 Lb -Inch Ix req= 0.01 Date 8/3/2010 Job# 2k10 -080 U= 1.2 I 0.0931 in3 1 I 0.1862 in3 1 30,000.00 psi Sxreq= 0.011039 in 3 OK OK safety factor (as per AISC 13th edition) Davis Engineers Steel Picket Fence Post Embedments Post section properties Gate Dimentions Post Spaciong Hight of Post(H) Design loads: Wind Presure % of Solid surface Pwind Check For Solid Signs Design Load M(Max(B,L)) N(Min(B,L)) M /N= Net Force Coef. Cf= Gust Effect Factor (G)= Allow Lat Soil- Bearing pressure capacity based on 1/3 of emb. Initial Guess For D S1 =2x SO x 0.333D Footing Width A(d)= (2.34 *P) /(S 1 *B) D(d)= 334.5 Lb 5ft 5 ft 1.00 1.2 0.85 Psolid sign=qz(h)xGxCf " 9; Psf Check Post Embedment Ft Ft Lb /sf Load Due To Psolid = Lb Moment Due To Psolid= 852.975 Lb -FT Date 8/3/2010 Job# 2k10 -080 W H 150 Lb /Ft3 (As per UBC Table 18 -1A) Depht = 0. 5xA( d)x {1 +SQRT[(1 +[(4.36h) /A(d)])]} 349.65 Lb /Ft2 ft 1.14 ft 3.30 ft OK Area 0.4842 in perimeter 8 in X- centroid 1 in Y- centroid 1 in Ix 0.7878 in4 ly 0.7878 in4 Ixy 0.4844 in4 r( 1.2755 in ry 1.2755 in ix -y 0.3032 in4 jx -y 0.3032 in4 I 4 • Davis Engineers Post Section Properties 1 2 x 2 x 0.065 6061 -T6 Alum 1 Sx= I Fy= 19000 psi E= 10100000 psi Y- centroid ly -► X- centroid fy Check Bending & Deflection(L/240max) M at base of footing= Sx Req= Date 8/3/2010 Job# 2k10 -080 11= 1.2 safely lemur tas per HIOU corn edition) I 0.7878 in3 I 0.7878 in3 1 15,833.33 psi 852.975 Lbs -ft 10235.7 Lbs -inch 0.65 in3 Ok. Ix Req= 0.405 in4 Ok. Area 0.3594 in perimeter 6 in X- centroid 1 in Y- centroid 0.5 in Ix 0.1518 in4 ly 0.5453 in4 Ixy 0.1797 in4 rx 0.65 in ry 1.2319 in ix -y 0.062 in4 jx -y 0.186 in4 Davis Engineers Hotizontal members Section Properties 1 2 x 1 x 0.065 6061 -T6 Alum 1 Sx= I I s r I Fb= Fy= 36000 psi E= 29000000 psi Ix Y- centroid ly X- centroid fy M= 1.25W(LA2)= 43.11914 Lb -ft 517.4297 Lb -Inch Date 8/3/2010 Job# 2k10 -080 i, l = 1.2 Check bending and Defelction(11240max) trib(70% oppened).= 2.5 ft W= wind pressure *trit 55.1925 Lb /ft 0.3036 in3 1 I 0.5453 in3 30,000.00 psi Sxreq= 0.017248 in 3 OK Ix req= 0.01 in4 OK if Ix N.G trial ly= 0.5453 in4 OK safety factor (as per AISC 13th edition) Area 02343 in perimeter 4 in X- centroid 0.5 in Y- centroid 1 in Ix 0.0931 in4 ly 0.0931 in4 Ixy 0.0586 in4 rx 0.6303 in ry 0.6303 in ix -y 0.0344 in4 jx -y 0.0344 in4 Davis Engineers Hotizontal members Section Properties 1 x 1 x 0.065 6061 -T6 Alum Fb= Fy= 36000 psi E= 29000000 psi Ix Y- centroid ly X- centroid fy Check bending and Defelction(L/240max) trib(50% oppened).= 2.5 ft W= wind pressure *tit 55.1925 Lb /ft M= 1.25W(LA2)= 43.11914 Lb -ft 517.4297 Lb -Inch Ix req= 0.01 Date 8/3/2010 Job# 2k10 -080 U= 1.2 I 0.0931 in3 I 0.1862 in3 1 30,000.00 psi 1 Sxreq= 0.017248 in 3 OK OK safety factor (as per AISC 13th edition) Davis Engineers Post Embedments Post section properties Gate Dimentions Post Spaciong Hight of Post(H) Check Post Embedment Load Due To Psolid = Moment Due To Psolid= Allow Lat Soil- Bearing pressure capacity based on 1/3 of emb. Initial Guess For D S1 =2 x SO x 0.333D Footing Width A(d)= (2.34 *P) /(S1 *B) D(d)= Ft Ft Design Toads: Wind Presure Lb /sf % of Solid surface Pwind 334.5 Lb Check For Solid Signs Design Load M(Max(B,L)) 6 ft N(Min(B,L)) 5 ft M /N= 1.20 Net Force Coef. Cf= 1.2 Gust Effect Factor (G)= 0.85 Psolid sign= gz(h)xGxCf Psf Lb 1023.57 Lb -FT Date 8/3/2010 Job# 2k10 -080 150 Lb /Ft3 (As per UBC Table 18 -1A) Depht = 0.5xA(d)x {1 +SQRT[(1 +[(4.36h)/A(d)])]} 374.625 Lb /Ft2 ft 1.28 ft 3.69 ft OK Area 0.4842 in perimeter 8 in X- centroid 1 in Y- centroid 1 in Ix 0.7878 in4 ly 0.7878 in4 Ixy 0.4844 in4 rx 1.2755 in ry 1.2755 in ix -y 0.3032 in4 jx -y 0.3032 in4 Davis Engineers Post Section Properties 2 x 2 x 0.065 6061 -T6 Alum I sr- I Fy= 19000 psi E= 10100000 psi Y- centroid ly X- centroid fy i2 Check Bending & Deflection(L/240max) Sx Req= Date 8/3/2010 Job# 2k10 -080 Sl= 1.2 seiery iacrvr kas per Hiai. IJUI edition) I 0.7878 in3 1 I 0.7878 in3 1 15,833.33 psi M at base of footing= 1023.57 Lbs -ft 12282.84 Lbs -inch 0.78 in3 Ok. Ix Req= 0.486 in4 Ok. Area 0.3594 in perimeter 6 in X- centroid 1 in Y- centroid 0.5 in Ix 0.1518 in4 ly 0.5453 in4 Ixy 0.1797 in4 rx 0.65 in ry 1.2319 in ix -y 0.062 in4 jx -y 0.186 in4 Davis Engineers Hotizontal members Section Properties 1 2 x 1 x 0.065 6061 -T6 Alum Fy= 36000 psi E= 29000000 psi Sx= I Ix Y- centroid ly __—► X- centroid fy 0 Check bending and Defelction(L1240max) trib(70% oppened).= 2.5 ft W= wind pressure *tit 55.1925 Lb /ft M= 1.25W (L ^2)= 62.09156 Lb -ft 745.0988 Lb -Inch Date 8/3/2010 Job# 2k10 -080 11= 1.2 0.3036 in3 1 I 0.5453 in3 1 30,000.00 psi 1 Sxreq= 0.024837 in 3 OK Ix req= 0.02 in4 OK if Ix N.G trial ly= 0.5453 in4 OK safety factor (as per AISC 13th edition) Area 0.2343 in perimeter 4 in X- centroid 0.5 in Y- centroid 1 in Ix 0.0931 in4 ly 0.0931 in4 Ixy 0.0586 in4 rx 0.6303 in ry 0.6303 in ix -y 0.0344 in4 jx -y 0.0344 in4 Davis Engineers Hotizontal members Section Properties 1 1 x 1 x 0.065 6061 -T6 Alum I sx= I I sY= I Fy= 36000 psi E= 29000000 psi Ix ___ Y- centroid ly -► X- centroid fy fy -► Check bending and Defelction(L/240max) trib(50% oppened).= 2.5 ft W= wind pressure *tit 55.1925 Lb /ft M= 1.25W(L ^2)= 62.09156 Lb -ft 745.0988 Lb -Inch Sxreq= 0.024837 in 3 OK Ix req= 0.02 Date 8/3/2010 Job# 2k10 -080 Ll= 1.2 0.0931 in3 I 0.1862 in3 1 1 30,000.00 psi 1 OK safety factor (as per AISC 13th edition) Davis Engineers Post Embedments Post section properties Gate Dimentions Post Spaciong Hight of Post(H) Design Toads: Wind Presure % of Solid surface Pwind Check For Solid Signs Design Load M(Max(B,L)) N(Min(B,L)) M /N= Net Force Coef. Cf= Gust Effect Factor (G)= Psolid sign = qz(h)xGxCf Check Post Embedment Load Due To Psolid = Moment Due To Psolid= Allow Lat Soil- Bearing pressure capacity based on 1/3 of emb. Initial Guess For D S1 =2 x SO x 0.333D Footing Width A(d)= (2.34 *P) /(S1 *B) D(d)= 401.4 Lb 4ft 6ft 0.67 1.2 0.85 Ft Ft Lb /sf Psf Lb 818.856 Lb -FT Date 8/3/2010 Job# 2k10 -080 150 Lb /Ft3 (As per UBC Table 18 -1A) Depht = 0. 5xA( d)x {1 +SQRT[(1 +[(4.36h) /A(d)])]} 324.675 Lb /Ft2 ft 0.98 ft 3.05 ft OK Area 0.4842 in perimeter 8 in X- centroid 1 in Y- centroid 1 in Ix 0.7878 in4 ly 0.7878 in4 Ixy 0.4844 in4 rx 1.2755 in ry 1.2755 in ix -y 0.3032 in4 jx -y 0.3032 in4 Davis Engineers Post Section Properties 2 x 2 x 0.065 6061 -T6 Alum 1 1 lsy=I Fy= 19000 psi E= 10100000 psi Ix _____ Y- centroid ly X- centroid fy Check Bending & Deflection(L/240max) Sx Req= Date 8/3/2010 Job# 2k10 -080 11= 1.2 safety racwr kas per Mrat.• roux edition) I 0.7878 in3 I 0.7878 in3 15,833.33 psi M at base of footing= 818.856 Lbs -ft 9826.272 Lbs -inch 0.62 in3 Ok. Ix Req= 0.467 in4 Ok. Area 0.3594 in perimeter 6 in X- centroid 1 in Y- centroid 0.5 in Ix 0.1518 in4 ly 0.5453 in4 Ixy 0.1797 in4 rx 0.65 in ry 1.2319 in ix -y 0.062 in4 jx -y 0.186 in4 Davis Engineers Hotizontal members Section Properties 2 x 1 x 0.065 6061-T6 Alum Sr: I ly X- centroid Fb= Fy= 36000 psi E= 29000000 psi Ix Y- centroid fy Date 8/3/2010 Job# 2k10 -080 Check bending and Defelction(L/240max) trib(70% oppened).= 3 ft W= wind pressure *tit 66.231 Lb /ft M= 1.25W(L ^2)= 33.1155 Lb -ft 397.386 Lb -Inch S2= 1.2 I 0.3036 in3 I 0.5453 in3 30,000.00 psi Sxreq= 0.013246 in 3 OK Ix req= 0.01 in4 OK if Ix N.G trial ly= 0.5453 in4 OK safety factor (as per AISC 13th edition) Area 0.2343 in perimeter 4 in X- centroid 0.5 in Y- centroid 1 in Ix 0.0931 in4 ly 0.0931 in4 by 0.0586 in4 rx 0.6303 in ry 0.6303 in ix -y 0.0344 in4 jx -y 0.0344 in4 if .4 Davis Engineers Hotizontal members Section Properties 1 x 1 x 0.065 6061 -T6 Alum Ix Sx= I Y- centroid -# Fy= 36000 psi E= 29000000 psi ly __ X- centroid fy M= 1.25W(L ^2)= 33.1155 Lb -ft 397.386 Lb -Inch Ix req= 0.01 Date 8/3/2010 Job# 2k10 -080 S1= 1.2 Check bending and Defelction(L1240max) trib(50% oppened).= 3 ft W= wind pressure *tit 66.231 Lb /ft I 0.0931 in3 1 I 0.1862 in3 1 30,000.00 psi Sxreq= 0.013246 in 3 OK OK safety factor (as per AISC 13th edition) Davis Engineers Post Embedments Post section properties Gate Dimentions Post Spaciong Hight of Post(H) Design Toads: Wind Presure % of Solid surface Pwind Check For Solid Signs Design Load M(Max(B,L)) N(Min(B,L)) M /N= Net Force Coef. Cf= Gust Effect Factor (G)= Psolid sign = qz(h)xGxCf Check Post Embedment Load Due To Psolid = Moment Due To Psolid= Allow Lat Soil- Bearing pressure capacity based on 1/3 of emb. Initial Guess For D S1=2 x SO x 0.333D Footing Width A(d)= (2.34 *P) /(S1 *B) D(d)= Ft Ft 401.4 Lb 5 ft 6ft 0.83 1.2 0.85 Lb /sf Psf Lb 1023.57 Lb -FT Date 8/3/2010 Job# 2k10 -080 150 Lb /Ft3 (As per UBC Table 18 -1A) Depht = 0.5xA(d)x {1 +SQRT[(1 +[(4.36h)/A(d)])]} 374.625 Lb /Ft2 ft 1.07 ft 3.31 ft OK Area 0.4842 in perimeter 8 in X- centroid 1 in Y- centroid 1 in Ix 0.7878 in4 ly 0.7878 in4 Ixy 0.4844 in4 rx 1.2755 in ry 1.2755 in ix -y 0.3032 in4 jx -y 0.3032 in4 Davis Engineers Post Section Properties 1 2 x 2 x 0.065 6061 -T6 Alum 1 Fy= 19000 psi E= 10100000 psi Ix Y- centroid ly X- centroid fy 0 -► -► -► Check Bending & Deflection(L/240max) Sx Req= Date 8/3/2010 Job# 2k10 -080 L2= 1.2 sarery racior kids per i iau iaur edition) I 0.7878 in3 1 I 0.7878 in3 i 15,833.33 psi M at base of footing= 1023.57 Lbs -ft 12282.84 Lbs -inch 0.78 in3 Ok. Ix Req= 0.584 in4 Ok. Area 0.3594 in perimeter 6 in X- centroid 1 in Y- centroid 0.5 in Ix 0.1518 in4 ly 0.5453 in4 Ixy 0.1797 in4 rx 0.65 in ry 1.2319 in ix -y 0.062 in4 jx -y 0.186 in4 w t • Davis Engineers Hotizontal members Section Properties 1 2 x 1 x 0.065 6061 -T6 Alum Fy= 36000 psi E= 29000000 psi Ix ___♦ Y- centroid ly __ X- centroid fy Date 8/3/2010 Job# 2k10 -080 Check bending and Defelction(LJ240max) trib(70% oppened).= 3 ft W= wind pressure *trit 66.231 Lb /ft M= 1.25W (L ^2)= 51.74297 Lb -ft 620.9156 Lb -Inch 12= 1.2 I 0.3036 in3 I 0.5453 in3 30,000.00 psi 1 Sxreq= 0.020697 in 3 OK Ix req= 0.02 in4 OK if Ix N.G trial Iy= 0.5453 in4 OK safety factor (as per AISC 13th edition) Area 0.2343 in perimeter 4 in X- centroid 0.5 in Y- centroid 1 in Ix 0.0931 in4 ly 0.0931 in4 Ixy 0.0586 in4 rx 0.6303 in ry 0.6303 in ix -y 0.0344 in4 jx -y 0.0344 in4 Davis Engineers Hotizontal members Section Properties 1 x 1 x 0.065 6061 -T6 Alum Fy= 36000 psi E= 29000000 psi Sx- I Ix Y- centroid I S Y- Iy X- centroid I Fb= fy Check bending and Defelction(11240max) trib(50% oppened).= 3 ft W= wind pressure *tit 66.231 Lb /ft M= 1.25W(L ^2)= 51.74297 Lb -ft 620.9156 Lb -Inch Ix req= 0.02 Date 8/3/2010 Job# 2k10 -080 S1= 1.2 I 0.0931 in3 1 I 0.1862 in3 30,000.00 psi Sxreq= 0.020697 in 3 OK OK safety factor (as per AISC 13th edition) (Gate openng) (FT) 3' -0 ki. (1.4e (FT 'X' (INC") VERTICAL P087 TOP 4 8otiai RAILS HINGES CONCRETE FOOTING Size Thickness Size Thickness 0 fib°" 0 (INCH) 'D'(Depth)(FT) 4'47' 4' -0' k 4' 2'x2' 0.0625' 2'xl' 0.0625' S/B 2 12' 3' -0' 5' -0' 2'x2' 0.0625' 2'x1' 0.0625' % 2 12' 3' -0' 6' -0 2'x2' 0.0625' 2'xl' 0.0625' %' 2 12' 3' -6' 3' -0' 2'x2' 0.0625' 2'xl' 0.0625' 5 /e, 2 12' 3' -8' 4'-0' 5' -0' 5' 2'x2' 0 .0625' 2'xl' 0.0625' S/8 2 12' 3' -0' 5' -0 2•'x2' 0.0625' 2'xl' 0.0625' S/6 2 12' 3' -3' 6' -0' 2'x2' 0.0625' 2'xl' 00625' S/8 2 12' 3' -6' 3' -0' 2'x2' 0.0625' 2'x1' 0.0625' 5/B 2 12' 3' -9' 4' -0' 6' -0' 6' 2'x2' 0.0625' 2'xl' 0 .0625' % 2 12' 3' -0' 5' -0' 2'x2' 0 .0625' 2'xl' 0.0625' 5/B 2 12' 3' -3' 2'x2' 0.0625' 2'xl' 0.0625' 5/e 2 12' 3' -9' NOTE: ALL MEMBERS TO BE WELDED 'A' GATE FRAME 2'x2'x0.062 ALUM. TUBE (ALL MEMBERS TO BE WELDED) VERT. POST ALUM. TUBE (SEE TABLE) to 111 _GATE - TOP RAIL ALUM. TUBE (SEE TABLE) (GATE OPENING , SEE TAB ) X. L 1J FOR 1-11N3 E5 NTH SIDES, SEE ISLE FOR G2 P. HINGE DTL. _GATE - BOTTOM RAIL -I ALUM. TUBE (SEE TABLE) 4-- w n 111 4 SEE TABLE FRONT V I E W d) U1 OC 0 1 1 1 SEE T ABLE 0 MARK VERT. PICKET l'xl' ALUM. TUBE TYP. VERT. POST ALUM. TUBE (SEE TABLE) � act c V1_ PROVIDE KEY LOCK REVISION DESCRIPTION DATE VERT. POST 2'x2', 16 GAUGE ALUM TUBE PROVIDE PLASTIC OR METAL POST CAP TYR (2) 3 /e'0 THRU BOLTS WITH NUT AND WASHER PER HINGE CONNECTION JOB No 2K10 - 080 (4 IIIIIIIII M0111111111 ; TOP RAIL l'x2', 16 GAUGE ALUM. TUBE SCALE: 3' : 1'-0' DATE: 01 -21 -2010 IIIIIIIIIIIII I IIIIIIIIIIIII I DAMS ENGINEERS 150 TAMIAMI CANAL ROAD MIAMI, FLORIDA 33144 (305) 266-2566 11111111 0.1.... *No I2136;5 E. No 0001809 GATE FRAME 2'x2'x0.062 ALUM TUBE, ALL MEMBERS TO BE WELDED N_ 5' LONG 'J' BOLT HINGE (SEE TABLE FOR SIZE 4 QTY.) GATE FRAME 2'x2'x0.062 ALUM TUBE, ALL MEMBERS TO BE WELDED FRONT VIEW TYPICAL -ZINC E DETAL. 61-40P DRAWINGS ALUM. SINGLE GATE 3' -0° TO 6' -0° WIDE ISLAND FENCE OF DADE (305) 888 -9090 SCALE: AS- S1 -IOUN VERT. PICKET l'xl'x0.062 ALUM. TUBE 41 4' o.c. MAX TYP. L J HAROLD GOBS P.E. CIVIL ENGINEER P E. No.1 0945 DRAW E.M. Mlami Shores Village - _ DATE APPROVED ZONING DEPT ' 1 fa � C� BLDG DEPT /U .-TI t SUBJECT TO COMPLIANCE WITH ALL FEDERS. STATE AND COUNTY RULES AND REGULATIONS COUNTY =WIDE • LAND . SURVEYORS INC. LAND SURVEYORS * PLANNERS P.O. 80X 823271 BOOTS ELORIDA•.•FL. 33082 -3271 (305) 7/2 -0766 • •. , N' g!o S7' so 24 714 per 60 204 ms ft • • • M LOCATION SKETCH NOT TO SCALE • LEGAL DESCRIPTION The East 125 feet of Lot 2 LESS the North 41.45 feet and the East 125 feet of Lot 3 and the East 125 feet of Lot 4 LESS the South 38.45 feet in Block 84 of MIAMI SHORES SECTION NO. 3, according to the plat thereof, as recorded in Plat Book 10 at Page 37 of the Public Records of Miami -Dade County, Florida. ) • 5). 6). record plat. Panel 0093 pirR PO. • SURVEYORS NOTES: 1). Legal description provided by client. 2). Only record plat easements are shown. 3). Right of way information obtained from 4). In Federal Flood Zones AE Elev. 9' & 10 ", last revised 3 -2 -94. Benchmark used- Dade County Benchmark # B -62. Elevations are referenced to National Geodetic Vertical Datum 1929 Adjustment (NGVD29). BOUNDARY, IMPROVEMENTS & ELEVATION SURVEY NAM FIG Jorge & •Rosann Cabrera 9550 N. Bayshore Dr. Miami Shores, FL C$RTIFICATR NJ?Es • NOT VALID =LEW WALED WITK AN MOSS= SURVEYORS SEAL." I HEREBY CERTIFY T THE SOBVgr REPRESENTED HEREON COMPLIES SITE TUI MINtMUN TECHNICAL MARDS ADOP'T'ED BT THE FLORIDA EOARD OF SURVEYORS Aug MAPPERS IN CHAPT 610 17 -6, FLORIDA IDNINIETRATIVS cODE, PORPORIN? T0 SECTION 472.027, orida Statutes. JOSEPH L. MARTIN PR0FESSI0 L LANG $URVEYOA *4368 1 STATE OF FLORIDA REVISIONS Apo N. J Cug5%QVC7 /N.ci P/'iM S ullye DRAWN 8Y SCALE x I /" 70 OATE 343-0y Y J Lt' F0✓ DATE 4.23 -o MOO Zwa.S - pipe ry '10 ••• • • • • ` te ..• • • • • ..• •• ••• • ••• • • • • • • • • • • • •• • • ••• • • • • ••• o . • /25 • • • • • - -"'"• • • • • • • • ••• ••• • • • • • •• •• • • . P,Pe pl9E•o • p p Lit CPL., OOL Access aw be dfyice located on and located no less oSc'i from bottom of V FBC 424.,17 SEP Rote t (pqc Sr tward • ea, ng, the gate han 54'� gate. 1.8 • NOTE: 'A' GATE FRAME 2'x2'x0.062 ALUM. TUBE (ALL MEMBERS TO BE WELDED) ALL MEMBERS TO BE WELDED VERT. POST ALUM. TUBE (SEE TABLE) d) U1 III I (GATE OPENING , SEE TAB ) L —GATE - TOP RAIL ALUM. TUBE (SEE TABLE) 'A' OR HIN3ES ° TI-I SIDES, SEE BL E FOR Q - `r'., P. HINGE D1L. J1 .( \ r _GATE - BOTTOM RAIL ALUM. TUBE (SEE TABLE) SEE TABLE FRONT 1l I E UJ 3/4'.1'-0' (Gate opening) (FT) 5'-0' 5' -0° (Height) (FT) 4' -0' 5' -0' 6' -0' ( 4' 5' 6' VERTICAL POST Size 2'x2' 2'x2' 2'x2' 2'x2' 2'x2' 2'x2' 2'x2' 2 2'x2' 2'x2' 2 Thickness 0.0625' 0.0625' 0.0625' 0 .0625' 0.0625' 0.0625' 0.0625' 0.0625' 0 .0625' 0 .0625' 0.0625' TOP 4 BOTTOM RAILS Size 2'x1' 2 5 x1' 2'x1' 2 2'xl' 2'xl' 2'xl' 2'x1' 2'xl' 2'x1' 2'x1' Thickness 0.0625' 0 .0625' 0.0625' 0-0625' 0-0625' 00625' 0.0625' 0.0625' 00625' 0.0625' 0 .0625' HINGES 0 548 5�8 54' 5 54' 5�8 5/ 5 48 V QTY. 2 2 2 2 2 2 2 2 2 2 2 CONCRETE FOOTING 0 (INCH) 12' 12' 12' 12' 12' 12' 12' 12' 12' 12' 12' 'D' (Depth) (FT) 3' -0 3' -8' 3' -0' 3' -3' 3' -6' 3' -3' 0 0 MARK III III I 0 SEE TABL VERT. PICKET l'xl'x0.062 ALUM. TUBE TYP. VERT. POST ALUM. TUBE (SEE TABLE) ALTERNATIVE ` LATCH, SEE DETAIL No. 1 PROVIDE KEY LOCK • REVISION DESCRIPTION VERT. POST 2'x2', 16 GAUGE ALUM TUBE PROVIDE PLASTIC OR METAL POST CAP TYP. (2) s/8 0 THRU BOLTS WITH NUT AND WASHER PER HINGE CONNECTION •• ••• • • • • • • • • • • • • • %1�IIIIIIIII TOP RAIL 1'x2', 16 GAUGE ALUM. TUBE II SCALE: 3' = r GATE FRAME 2'x2'x0.062 ALUM TUBE, ALL MEMBERS TO BE WELDED TOP VIEW 5' LONG 'J' BOLT HINGE (SEE TABLE FOR SIZE 4 QTY.) GATE I FRAM I E 2'x2'x0.062 ALUM TUBE, ALL MEMBERS TO BE WELDED FRONT VIEW TYPICAL H- -TINGE DETAL VERT. PICKET l'xl'x0.062 ALUM. TUBE 9 4' o.c. MAX. TYP. 1 —r L_ J HAROLD GOBS P.E. c CIVIL EN .INFER P.E. No.lO:1 DATE • ..- • • Pa l -•— • • • • •. • • • _• • • • •• O.L. *No 121365 E.B. No 0001809 AmI'• NG INFERS 94, 1,Lit.:4I t1 CANAL ROAD MIAMI, FLORIDA 33144 • • • ...�30a� 2&67-266. • :C:S:No• : • • BATE: • • 01 -21 -2010 SHOP DRAWINGS ALUM. SINGLE GATE 3' -0° TO 6' -0° WIDE ISLAND FENCE OF DADS (305) 888 -9090 SCALE: AS -SHOWN DRAW E 1„I. 3/4' DIA. SOLID ALUM. BAR PIN W/ 1 1/2'x3'x1/4' HANDLE 3' // 1 3/16 I) I' DIA. x 1 PIPE SLE (TYP.) < TYP. 8' ALUM. EvE 1 CFTIONAL LATCH PETAL 4 * 1 N.T.S. / REVISION DESCRIPTION MARK DATE 2. BOLTS B OTHER FASTENERS DIRECTLY IN CONTACT WITH ALUMINUM MEMBERS SHALL. BE ALUMINUM, STAINLESS STEEL OR ELECTRO GALVANIZED STEEL. DOUBLE CADMIUM PLATED STEEL BOLTS MAY BE ALLOWED UPON WRITTEN REQUEST TO THE ENGINEER OF RECORD. 5. ALUMINUM PARTS SHALL BE WELDED WITH AN INERT -GAS SHIELDED ARC OR RESISTANCE WELDING PROCESS. FLUX WELDING 15 NOT ALLOWED. FILLER ALLOYS SHALL SE AS AMERICAN WELDING SOCIETY SPECIFICATIONS A5.IO -69. ALL WELDING SHALL BE PERFORMED BY CERTIFIED WELDERS. 4. DURING ERECTION, ALUMINUM STRUCTURES SHALL BE ADEQUATELY BRACED AND FASTENED TO RESIST DEAD, WIND AND ERECTION LOADS. 5. ALUMINUM IN CONTACT WITH NON - COMPATIBLE METALS SUCH AS STEEL SHALL BE PROTECTED AS PER FBC 2003.8.4.2. 6. ALUMINUM IN CONTACT WITH CONCRETE SHALL SE PROTECTED WITH AN ALKALI RESISTANT COATING. T ALUMINUM IN CONTACT WITH WOOD SHALL BE PROTECTED WITH TWO COATS OF ALUMINUM METAL- AND - MASONRY PAINT. •• ••• • • • • • •• ALUMINUM RAIL NO NOTES: ALL ALUMINUM SHALL BE TYPE 6061 -T6, UNLESS NOTED OTHERWISE (U.N.0) ALL CONECTIONS TO EE WELDED. USE g/(6" MINIMUM WELD SIZE, TYPICAL U.N.O. CONCRETE NOTES: I. ALL CONCRETE SHALL ATTAIN A MINIMUM COMPRESSIVE STRENGTH OF 3000P51. 2. AGREGATES TO BE CLEAN AND WELL GRADED. MAXIMUM SIZE TO BE I ". 5. CONCRETE SLUMP TO BE 3" MINIMUM TO 5" MAXIMUM. SOIL STATEMENT I. THE SOIL 15 ASSUMED TO CONSIST OF UNDISTURBED SAND AND ROCK WITH AN ALLOWABLE BEARING CAPACITY OF 2.0 KSF. SHOULD OTHER CONDITIONS SE ENCOUNTERED, CONTACT THE ENGINEER BEFORE PROCEEDING WITH THE WORK. AT THE TIME OF CONSTRUCTION, A L=1 i =hi ATTESTING THAT CONDITIONS ARE SIMILAR TO THOSE UPON WHICH THE DESIGN 15 BASET WILL BE SUBMITTED TO THE BUILDING OFFICIAL. • v • • • • • • • •: 'fit . 0 . t 0 : 111 v ' E.B. No 0001809 DAVIS ENGINEERS •• :. &, ' T,4T:(I4111I CANAL ROAD • • ; 1:',hA1 - L • 1 33144 (305) 266 -2566 • • V:3 TIC:' ; IJATE: :.' 14-4)63 01 -21 -2010 1.4.CtioAc HAROLD COBS P.E. CIVIL ENGINEER P E. No.IO SH0P DRAWINGS ALUM. SINGLE GATE 3' -0" TO 6' -0° WIDE ISLAND FENCE OF DADE (305) SSS -9090 SCALE: DRAW AS -SHOWN E.M. If)) 3 g 1[1) OCT 012,010 v sd d.. do T‘,C C —1(119 Davis Engineers. - 780 Tamiami Canal Road Miami, Florida 33144 PH: (305) 266 -2566 FX: (305) 267 -1556 JOB TITLE Island Fence STRUCTURAL CALCULATIO FOR Island Fence JOB NO. 2K10 - 080 SHEET NO. CALCULATED BY DATE CHECKED BY DATE www.struware.com Harold R. Cobb, P.E. Structural Engineer FL. No.: 10993 Code Search, I. Code: ASCE 7 - 05 11. Occupancy: Occupancy Group = 11I. Type of Construction: Fire Rating: V. Davis Engineers. 780 Tarniami Canal Road Miami, Florida 33144 PH: (305) 266 -2566 FX: (305) 267 -1556 Floor Stairs & Exitways Balcony Mechanical Partitions Importance Factor Basic Wind speed Directionality (Kd) Mean Roof Ht (h) Parapet ht above grd Exposure Category Enclosure Classif. Internal pressure Building length (L) Least width (B) Kh case 1 Kb case 2 Roof = Floor = Wind Loads : ASCE 7 - 05 Topographic Factor (Kzt) Topography Hill Height (H) Half Hill Length (Lh) Actual H/Lh = Use H/Lh = Modified Lh = From top of crest: x= Bldg up /down wind? H/Lh= 0.50 x/Lh = 0.31 z/Lh = 0.09 At Mean Roof Ht: Kzt = (1 +K ^2 = R Residential 0.0 hr 0.0 hr IV. Live Loads: Roof angle (0) 0.00 / 12 0.0 deg Roof 0 to 200 sf: 20 psf 200 to 600 sf: 24 - 0.02Area, but not less than 12 psf over 600 sf: 12 psf Residential: 0 psf 0 psf 100 psf N/A N/A N/A 1.00 146 mph 0.85 6.0 ft 0.0 ft C Partially Enclosed +/ -0.55 100.0 ft 100.0 ft 0.849 0.849 Flat 80.0 ft 100.0 ft 0.80 0.50 160.0 ft 50.0 ft downwind K 1 = K2 = K3 = 0.000 0.792 1.000 1.000 JOB TITLE Island Fence JOB NO. 2K10 - 080 CALCULATED BY CHECKED BY SHEET NO. DATE DATE www.struware.com ESCARPMENT V(Z) x(upviind) Speed -up x(downwind) 2D RIDGE or 3D AXISYMMETRICAL HILL Davis Engineers, JOB TITLE Island Fence 780 Tamiami ('anal Road Miami, Florida 33144 JOB NO. 2K10 -080 PH: (305) 266 -2566 CALCULATED BY FX: (305) 267 -1556 CHECKED BY V. Wind Loads - Other Structures: A. Solid Freestanding Walls & Solid Signs (& open signs with Tess than 30% open) Dist to sign top (h) Height (s) Width (B) Wall Return (Lr) Directionality (Kd) Percent of open area to gross area Height to centroid of Af (z) Width (zero if round) Diameter (zero if rest) Percent of open area to gross area Directionality (Kd) D. Trussed Towers Tower Cross Section Member Shape Directionality (Kd) Importance Factor = Gust Effect Factor (G) _ Kzt = square flat 1.00 8.0 ft 8.0 ft 200.0 ft 0.0 ft 0.85 0.0% 3.0 ft 3.2 ft 0.0 ft 67.0% 0.85 C. Chimneys, Tanks & Similar Structures Height to centroid of Af (z) 4.5 ft Cross - Section Square Directionality (Kd) 0.90 Height (h) 3.5 ft Width (D) 3.2 ft Type of Surface N/A Height to centroid of Af (z) 15.0 ft E = 0.27 1.00 0.85 Wind Speed 1.00 Exposure s/h = B/s = Lr /s = Kz = qz = Case C reduction factors Factor if s/h >0.8 = Wall return factor forCfatOtos= E _ Cf = Square (wind along diagonal) Cf = 1.00 F =gzGCfAf= 35.5Af Af = 10.0 sf F = 355 lbs Square (wind along tower diagonal) Cf = 3.24 F =gzGCfAf = 127.5 Af Solid Area: Af = 10.0 sf L' - W7C IL. 1.00 25.00 0.00 0.849 39.4 psf Open reduction factor = 1.00 0.80 1.00 B. Open Signs & Lattice Frameworks (openings 30% or more of gross area) 146 mph C Horiz dist from windward edge Otos s to 2s 2sto3s 3s to 4s 4s to 5s 5s to lOs >10s Case A & B Cf = F =gzGCfAs = As = F = CaseC Cf 3.29 2.07 1.59 1.31 1.23 0.78 0.44 Kz = Base pressure (qz) = F =g = 0.33 Solid Area A = 1.6 F = Kz = 0.849 Base pressure (qz) = 41.7 psf b/D = 1.11 Square (wind normal to face) Cf = 1.30 F =gZGCfAf= Af = F= Diagonal wind factor = Round member factor = SHEET NO. DATE DATE 1.30 43.5 As 10.0 sf 435 lbs F= azGCfAs (nst) 110.1 As 69.1 As 53.0 As 43.7 As 41.2 As 26.1 As 14.7 As 0.849 39.4 psf 53.5 Af 1.0 sf 54 lbs 46.1 Af 10.0 sf 461 lbs Kz = 0.849 Base pressure (qz) = 46.3 psf 1.2 1.000 Square (wind normal to face) Cr = 2.70 F =g = 106.3 Af Solid Area: A = 10.0 sf