Loading...
RF-10-2071RE -ROOF FLAT ONLY Passe /,z-6-/-0 Inspector Comments e6.- Failed Correction Needed Re- Inspection Fee No Additional Inspections can be scheduled re- inspection fee is paid. until Inspection Number: INSP- 154024 Permit Number: RF -11 -10 -2071 1 Inspection Date: December 06, 2010 Inspector: Bruhn, Norman Owner: RANDLE, JULIA Job Address: 150 NE 103 Street Miami Shores, FL 33138- Project: <NONE> Contractor: MIAMI ROOFING SYSTEMS INC Building Deaartment Comments December 07, 2010 Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 For Inspections please call: (305)762 -4949 Permit Type: Roof Inspection Type: Final Work Classification: Flat Phone Number Parcel Number 1132060131740 Page 1 of 1 On or about l a J a I l b (Date & time) rot secondary water barrier work at 1 50 ,WE /d 3 State of Florida County of Dade: RE: Permit # ?II — lo-ofll 1 "Sayler R. y+i n Swom to and subscribed before me this 2 4) d y of 0Ce.Am.b..U7b Notary Public, Sate of Florida at Large Revised on 5/21/2009 P s: Co F ,fz`P Bonded Expires Apr 14, 2012 # DO 779122 tional Notary Assn. M iami Shores Viiiage Building Department DATE: / la I) D INSPECTION AFFIDAVIT , licensed as a (n) Contractor / Engineer / Architect, (Print name and circle License Type) FS 468 Building Inspector License #: CCCO5 ?3D L , I did personally inspect the roof deck nailing and 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 (Complete Job Site Address) Based upon that examination I have determined the installation was done according to the Hurricane Mitigation Retrofit Manual (Based on 553.844 F.S) The undersigned, being the first duly swom, deposes and says that he /she is the contractor for the above property mentioned. *General, Building, Residential, or Roofing Contractors or an ~ • widual certified under 468 F.S. to make such an inspection. Include photographs of each plane of the roof with pemlit# and address # clearly shown marked on the deck for each inspection ' INSURANCE 1.11 MIDDI 1/14/2010 01 INFORMATION CERTIFICATE EXTEND OR BELOW. THIS CERTIFICATE IS ISSUED AS A MATTER OF ONLY AND CONFERS NO RIGHTS UPON THE HOLDER, THIS CERTIFICATE DOES NOT AMEND, ALTER THE COVERAGE AFFORDED BY THE POLICIES INSURERS AFFORDING COVERAGE NAIC# INSURER A. CANAL INDEMNITY INSURANCE CO MED EXP (Any one person) INSURER B: PERSONAL &ADV INJURY INSURER 0: GENERAL AGGREGATE INSURER D: PRODUCTS • COMP /OPAOG INSURER E COMBINED SINGLE LIMIT (EA aeCidend $ : PERIOD INDICATED. NOTWITHSTANDING :H THIS CERTIFICATE MAY BE ISSUED OR 3, EXCLUSIONS AND CONDITIONS OF SUCH LIMITS EACH OCCURRENCE $ 1,000,000 PREMISEStEa °ceumne4) $ 50,000 MED EXP (Any one person) $ 1,000 PERSONAL &ADV INJURY 3 1 , 00 000 GENERAL AGGREGATE s 2,000 s 1, 000 , 00 0 PRODUCTS • COMP /OPAOG COMBINED SINGLE LIMIT (EA aeCidend $ BODILY INJURY (Par parson) S BODILY INJURY (PeraadenU $ PROPERTY DAMAGE (PeearsadenI $ AUTO ONLY- EA AOC IDENT 3 OTHER THAN EAACC $ AUTO ONLY' AGG 5 EACH OCCURRENCE 3 AGGREGATE 3 5 $ a TORYUMITS I IOFR• E.L EACH ACCIDENT $ E.L. DISEASE - EA EMPLOYEE $ E L. DISEASE - POLICY LIMIT 3 11/30/2010 17:14 FAX ADDRDn, CERTIFICATE OF LIABILIT PRODUCER BOSNAN INSURANCE GROUP 4377 W 16 Ave Hialeah, FL 33012 (305)828 -6565 INSURED MIAMI ROOFING SYSTEMS, INC COVERAGES THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLI ANY REQUIREMENT, TERM OR CONDMON OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHU MAY PERTAIN, THE INSURANCE AFFORDED 81 THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERM POLICIES. AGGREGATE LIMITS SHOWN MAY HAVE BEEN REDUCED EY PAID CLAIMS. eR AD3'L L PO1 EXPIRATIO LTR HdeDD TYRE DF INS RAN POLICY NUMBER �E D IMM/rID/VYY IN GL97398 A X GENERAL LIABILITY X COMMERCIAL GENERAL LIABILITY CLAIMSMADE OCCUR X 8/I DED 2500 X P/D DED 2500 GE•L AGGREGATE LIMIT APPLIES PER: — j POLICY n PRO- n LOC AUTOMOBILE LIABILITY ANYAUTO AU. OWNED AUTOS SCHEDULED AUTOS HIRED AUTOS NON - OWNEDAUTOS GARAGE LIABILITY ANYAUTO EXCESS/UMBRELLA LU$ILITY OCCUR U CLAIMSMADE DEDUCTIBLE RETENTION $ WORKERS COMPS N SATION AN D EMPLOYERS' LIABILITY ANY FROTRiIE1'OPJPARTNEFYDIECUTIVE OFFICER/MEMBER EXCLUDED? K desenbounder SPECIAL PROVISIONS baler/ OTHER PO EFFECTIVE 01/18/10 DESCRIPTION OF OPERATIONS / LOCATIONS /VEHICLES/ EXCLUSIONS ADDED BY ENDORSEMENT / SP ECIAL PROVISIONS 01/18/11 CERTIFICATE HOLDER CITY OF MIAMI SHORES BUILDING DEPARTMENT 10050 NE 2 AVE. MIAMI SHORES, FL 33138 'FAX: (305) 756 -8972 SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATIO DATE THEREOF, THE ISSUING INSURER WILL ENDEAVOR TO MAIL' ( DAYS WRITTEN NOTICE TO THE CERTIFICATE HOLDER NAMED TO THE LEFT, BUT FAILURE TO D050 SHALL IMPOSE NO OBLIGATION OR LIASILEY OF ANY KIND UPON THE INSURER ITS AGENTS OR REPRESENTATIVES, AUTHORIZED REPRESENTATIVE ACORD25(2001 /08) 667 NW 101 STREET MIAMI, FL 33150 CANCELLATION !j 003 /003 ® C • - D CORP TION 1988 NOTICE OF COMMENCEMENT A RECORDED COPY MUST BE POSTED ON THE JOB SITE AT TIME OF FIRST INSPECTION PERMIT NO. TAX FOLIO NO. STATE OF FLORIDA: COUNTY OF MIAMI -DADE: THE UNDERSIGNED hereby gives notice that Improvements will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information Is provided In the Notice of Commencement. 1. Legal description of property and street/address: 150 (UE /03 / 2. Description of improvement: 3. Owner(s) name and address: 7 Q aaticite Cd r 15• Al 3 Interest in property: Name and address of fee simple titleholder. 4. Contractor's name and address: Notary Public Print Notary's Name My commission expires: 123.01 -52 PAGE 4 W02 14, D P " �3rr ture of Owner Owner's Nam -.: ;_ .f 't• �,. Sworn to and subscribed before me this / day of Ot// 111111111111111111111111111111111111111111111 CF 4 2010R0791862 OR Bk 27499 Pa 04506 (1139) RECORDED 11/23/2010 11:10.05 HARVEY RUVINr CLERK OF COURT MIAtlI -DADE COUNTYr FLORIDA LAST PAGE ores F/ zer3 5. Surety: (Payment bond required by owner from contractor, If any) Name and address: Amount of bond $ 6. Lender's name and address: 7. Persons within the state of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 713.13(1Xa)7., Florida Statutes, Name and address: 8. In addition to himself, Owners designates the following person(s) to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b), Florida Statutes. Name and address: 9. Expiration date of this Notice of Commencement (the expiration date is 1 year from the date of recording unless a different date is specified) Book274991Page450 CFN #20100791862 Page 1 of 1 ul3olio Oana BUILDING PERMIT APPLICATION FBC 20 Tenant/Lessee Name Email FOLIO / PARCEL # Job Address (where the work is being done) City Miami Shores Village Architect/Engineer's Name (if applicable) Value of Work For this Permit $ cg qc . Ct) Type of Work: ❑Addition DAlteration Miami Shores Village (- Building Department NOV 2. 2010 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 INSPECTION'S PHONE NUMBER: (305) 762.4949 Submittal Fee Notary $ Scanning $ Radon $ DPBR $ Double Fee $ Violation date: Training/Education Fee $ Zip Permit r o. I 1 Master Permit No. Permit Type: BUILDING ROOFING. I -793-125s-co Owner's Name (Fee Simple Titleholder) JUI i Ct ?Q t Phone # 3 - Owner's Address 1 �� O NE AO 3 rd -pa City Ift J 1 c.`7'IOr .3 State P1 Z Phone # /60 Pe /d 3 rd dve§ County Miami -Dade Zip B Y <. 33/5D Is Building Historically Designated YES NO Flood Zone Contractor's Company Name Hia,'n, `- /� -H R CJ �; 5 Phone #( '6J 95 5554 � Contractor's Address ' / AR A-) Iv 1 City I.iQr i - I nn II State Zip /� Qualifier Name MV! e ✓ K 4-i net Phone # (3) 951- 655(/ State Certificate or Registration No. Certificate of Co etency No. R_ 'Contact PhonE-mail rr1} a .»: AY17 /O $ 3 400. CQ/7'! Phone # Square / Linear Footage Of Work: 395 ONew > Repair/R.eplace ❑ Demolition �7►'T i . I4FS 7, 4 §. ppa iin,{ v .rte 41,.,74AT :?. i * * *** *$t * *i** *ii:* ** * * * * * * * * * * * * * ** ************* * * * * * * * * * * * * * * * * * ** * * * * * * * * * * ** Permit Fee $ � cc) CCF $ CO /CC .$ Technology Fee $ Bond $ Structural Review. $ Total Fee Now Due $ See Reverse side —+ Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that. all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. (Revised 07 /10 /07)(Revised 06/10/2009) Owner or Agent trument was acknowledged before me this Ie , 20 by " jj gG/ die , who is personally known to me or who has produced 70L As identification and who did take an oath. APPROVED BY /C 09 Plans Examiner Zoning Engineer Signature Contractor ad t ent,was acknowledged before me thi MVO , 20 in, by - J a va, I me known to me or has produced as identification and who did take an oath. The foregoing ins day of N� who is personally NOTARY PUBLIC: Clerk checked OWNERS'S AFFIDAVIT OF EXEMPTION ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR EXISTING SITE - BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES PERSUANT TO SECTION 553.844 F.S. To: Miami Shores Village Building Department 10050 NE 2 Ave Miami Shores, Fl 33138 Re: Owner's Name: )1 iG - 1 le.. Property Address: /50 (L E /0 ? Roofing Permit Number: Dear Building Official: r building because: )� The just valuation for the structure for purpose of ad valorem taxation is Tess than $300,000.00. Please attach proof of ad valorem taxation. ❑ The building was constructed in compliance with the provisions of the Florida Building Code (FBC) or with the provisions of 1994 edition of the South Florida Building Code (1994 SFBC) TLaka__ SUL Print Name certify that I am not required to retrofit the roof to wall connections of my State of Florida County of Dade The undersigned, being the first duly swom, deposes and says that he /she is / the _ owner for the above property mentioned. Sworn to and subscribed before me this day of (Jl i?bad tit) /O Notary Public, Sate of Florida at Large Revised on 5/21/2009 %dr ?I 11TI . . Ban IA MARTINEZ Public - State of Flog sion Expires Apr 14, 2012 M iami Shores Viiiage Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 Date: 1, bq fission # 0D 77912 uGn National Notary Assn. • When the just valuation of the structure for pu .... • .. r , , r _ 10 or° . a t 0.00, and the building was not constricted with FBC nor a 1994 SFBC. Then you must provide a building application from a General Contractor for the Roof to Wall connection Hurricane Mitigation. SECTION R HIGH VELOCITY HURRICANE ZONES — REQUIRE CONSIDERATIONS R4402.13.1 Scope. As it pertains to the section, it is the responsibility of roofing contractor to provide the owner with the required roofing permit, and to explain to the owner the content of the section. The provisions of Section R4402 govem the minimum requirements and standards of the industry for roofing system installations. Additionally, the following items should be addressed as part of the agreement between the owner ant the contractor. The owners initial in the designated space indicates that the item has been explained. 1. kW' Aesthetics- Workmanship: the workmanship provisions of Section R4402 are for the purpose of t • viding that the roof system meets the wind resistance and water instruction performance standards. esthetics (appearance) are not a consideration with respect to workmanship provisions. Aesthetic issues such as color or architectural appearance, that are not part of a zoning code, should be addressed as part of the agreement between the owner and the contractor. "L Renailing wood decks: When replacing roofing, the existing wood roof deck may have to be nailed in accordance with the current provisions of Section R4403. (The roof deck is usually concealed prior o removing the existing roof system). Common roofs: Common roofs are those which have no visible delineation between neighboring its (i.e., townhouses, condominiums, etc.) In buildings with common roofs, the roofing contractor and/or owner should notify the occupants of adjacent units of roofing to be performed. Exposed Ceiling: Exposed, open beam ceilings are where the underside of the roof decking can viewe • m below. The owner may wish to maintain the architectural appearance; therefore, roofing nail enetration of the underside of the decking may not be acceptable. This provides the option of maintaining the appearance. (� onding water: The current roof system and /or deck of the bu ilding may not drain well and may se wa e pond (accumulate) in low -lying areas of the roof. Pounding can, be an.,.indication pf structural stress and may require the review of a professional structural engirfie oundinq inay shorten the life . expectancy and performance of the new roofing system. Pounding conditions may not be evident until the original roofing system is removed. Pounding conditions should be co bed; , xi Overflow scuppers (wall outlets): It is required that rainwater flows off so that the roof is not m a buildup of water. Perimeter /edge wall or other roof extension may block this discharge if verflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in accordance with the requirements of Sections R4402, R4403 and R4413. Ventilation: Most roof structures should have some ability to vent natural airflow through the rior oflhe structure assembly (the building itself). The existing amount of attic ventilation shall not be duced. It may be beneficial to consider additional venting which can result in extending the service life of the roof. er /Agent's Signature Date Revised on 7/9/2009 LD I MOIRTIVE St ►3.1FCT TO COMPLIANCE WITH 241 ALL FEDERAL Contracto Signature tic Date Date ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Florida Building Code Edition 2007 High - Velocity Hurricane Zone Uniform Permit Application Form. Spntinn A (General Information) Master Permit No. Process No. Contractor's Name � iGIfV11�1(t� Sits6115 � Job Address 150 NE IO ?j Low Slope ❑ Asphaltic Shingles ❑ Mechanically Fastened Tile ❑ Metal PaneUShingles ❑ Prescriptive BUR -RAS 160 ROOF TYPE ❑ New Roof Reroofing ❑ Recovering ROOF SYSTEM INFORMATION Low Slope Roof Area (SF) Steep Sloped Roof Area (SF) 323 FLORIDA BUILDING CODE — BUILDING ❑ Mortar /Adhesive Set Tile ❑ Wood Shingles /Shakes ❑ Repair ❑ Maintenance Total (SF) Section B (Roof Pla) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. i t 1�1 Section C MIAMI-DADE COUNTY "Delivering Excellence Every Day" Fill in the specific roof assembly components. if a component Is not required, Insert not applicable (n!a) In the text box. Top Ply: 1 ply APP 180 FR Top Ply Fastening / Bonding Material: ROOF SYSTEM MANUFACTURER: Product Approval (NOA): 05- 0830.10 System Type: Wind Uplift Pressures, From RAS 128 or Sealed Calculations:, (P1) Field: 49.2 psf, (P2) Perimeters: (P3) Corners: psf Maximum Design Pressure From NOA 142 :4? i Roof Slope: ": 12 Roof Mean Height: Parapet Walls: No 0 Yes Parapet wall Height: Deck Type: Support Spacing: Alternate Deck Type: Existing Roof: Fire Barrier: Vapor Barrier: I N/A Anchor Sheet: psf —5/8" Plywood— " o/c IN /A Anchor Sheet Fastener/ Bonding Material: Insulation Base Layer Size & Thickness: u Insulation Base Layer Fastener / Bonding Material: L) Insulation Top Layer Size & hickness: Firestone Insulation Top Layer Fastener / Bonding Material: hN /A ____.._....._.__...._._.,.___ ____....___...... Base Sheet(s) & No. of Ply(s): I2 ply of firestone MB Base Base Sheet Fastener / Bonding Material: t rte PIy Sheet(s) & No. of Ply(s): 1N /A 1 PIy Sheet Fastener / Bonding Material: I N/A Miami -Dade County Building Department Electronic Application High Velocity Hurricane Zone Roofing Permit Application Form Section C page (Low Slope Roof Systems) ft. Surfacing: SINGLE PLY MEMBRANE: Single Ply Manufacturer / Type: i N/A Single Ply Sheet Width: No. of Single Ply 1/2 sheets: Single Pty Membrane Fastening / Bonding Material: I N/A ❑ FASTENER SPACING FOR BASESHEET ATTACHMENT ❑ SINGLE PLY MEMBRANE ATTACHMENT 1. Field: N/A 2. Perimeter. Ell Coping Material: " o/c @ Laps & " 1/2 Sheet Width: " o/c @ Laps & Wood Nailer Fastener Type and Spacing: EDGE & COPING METAL SIZES: Edge Metal Material: — Galvanized Metal— Edge Size: I-3" face 26 ga.— Hook Strip Size: Edge Metal Attachment: -gig , t 7JA I S rows rows 3. Comer: , " o/c @ Laps & rows " olc NUMBER OF FASTENERS PER INSULATION BOARD: 3. Comer: " o/c If " o/c 1. Field: 1(j 2. Perimeter: Insulation Fastener Type : WOOD NAILER TYPE AND SIZE: 1N/A — SELECT EDGE METAL HOOK STRIP SIZE -- SE LECT P ARAPET WALL COPING MATERIAL -- Coping Size: — SELECT COPING METAL SIZE OR THICKNESS — Hook Strip Size: - SELECT COPING METAL HOOK STRIP SIZE— Parapet Coping Metal Attachment: N /A Section C2d P1IAM MADE e COUNTY "Delivering Excellence Every Day" Illustrate Components Noted and Details as Applicable: Woodblocking, Gutter, Edge Terminations /Stripping /Flashing, Continuous Cleat, Cant Strip, Base Flashing, Counterflashing, Coping, Etc. Indicate: Mean Roof Height, Parapet Height, Height of Base Flashing, Component Material, Material Thickness, Fastener Type, Fastener Spacing Or: Submit Manufacturers Details that Comply with RAS -111 and Chapter 16. x16 e,‘/,' C v ALA. p,ci„ Miami -Dade County Building Department Electronic Application High Velocity Hurricane Zone Roofing Permit Application Form Parapet Wall Height N Mean Roof Height 1 :k1embrane Type: Deck Type 11: Deck Description: System Type D(1): All General and Syst Layer Fastening: Ply Sheet: Surfacing: APP Wood, Insulated l ' /32" or greater plywood or wood plank fasten to supports with # 8 x 2W wood 'crews at a maximum spacing of 6" o.c. All layers of insulation and base sheet simultaneously attached. ystem Limitations !so 95+ GL or Approved Polyisocyanurate Minimum 1.5" thick N/A N/A Note: Top layer shall have preliminary attachment, prior to the installation of the base/anchor sheet, at a minimum application rate of two fasteners per board for insulation boards having no dimension greater than 4 ft., and four fasteners for any insulation board having no dimension greater than 8 ft. All layers of insulation and base sheet shall be simultaneously fastened. See chor 'sheet below for fasteners and density. Insulation Fasteners Fastener Densitv/ft (Table 3) ne s ly of Firestone MB Base Shee ' with a 4" side lap mechanically fastened throu . ► • r, described below: Fasten base sheet with Firestone AP or HD fasteners and plates at a spacing of 12" o.c. in the 4" side lap and two rows staggered in the center of the sheet 12" o.c. (Optional) One or more plies of Firestone MB Base Sheet, Type IV or VI ply sheet or other listed base sheet applied in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbsJsq.; or one ply Firestone APP 160 or API' 170 torch applied. One ply of APP 160, APP 170, APP 180 the base ply, with overlaps staggered 12 ". (Optional) Install one of the following: 1. Gravel or slag at 400 lb. and 3001b., respectively, set in a flood coat of type 111 or IV asphalt at 601bJsq.. 2. Karnak No. 97, No. 97 AF or No. 169 at an application rate of 11 galJsq.. 3. Owens Corning Fiberglass Cap sheet GAF Mineral Surface Capsheet or Manville Glaskap in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq.. Maximum Design Pressure: 52.5 psf (See General Limitation #7) 180 FR torch applied paralle NOA No.: 05- 0830.10 Expiration Date: 03/08/11 Approval Date: 12/29/05 Page 28 of 34 TGFU.R9516 - Roofing Systems file: / / /C:/ Users / Jose /Documents /Work%20 %23 %202 %20(Miarrr 10137 ONLINE CERTIFICATIONS DIRECTORY Roofing Systems Page Bottom See General Information for Roofina Systems FIRESTONE BUILDING PRODUCTS CO L L C 250 W 96TH ST INDIANAPOLIS, IN 46260 USA TGFU °R9516 Roofing Systems R9516 References to Type G1 and Type G2 ply and base sheets Include "Type IV°, "Type VI" (Type G1), "Ply IV (4) M° (Type G1), "Ply VI (6) M" (Type G1), °MB Base Sheet M" (Type G2), °MB Base Sheet° (Type G2) in any of the following Classifications. °Firestone Venting Base Sheet" (Type G3) may be used in lieu of any Type G2 base In any applicable non - combustible Classification. "SBS Poly Base Sheet° can be used In any non - combustible deck system which utilizes a Firestone SBS cap sheet. "ISOGARD" and "ISO 300° are acceptable alternates to "ISO 95 +" in any applicable Classification. °I.S.O.FIX Adhesive° may be used in any of the following Classifications to adhere insulation to the roof deck. "I.S.O. Spray"' S° may be used in any of the following Classifications to adhere insulation to both non - combustible roof deck substrates and other insulation layers including wood fiberboard and G -P Gypsum Corp. "Dens -Deck® Roofboard" or "DensDeck Prime® Roofboard or "DensDeck DuraGuard'" Roofboard." "Tapered ISO 95 +CAN" may be substituted for "ISO 95+CAN" in any of the systems listed below. "ISO 95 +CAN° may be perforated on one side for use as the contact side for BUR or modified bitumen membrane. 1. Dedr: NC Incline: 3 Insulation: — "LSO 95+FK ", "GL ", "GW° or "Rhoflex Isocyanurate FK °, "GL ", "GW ", any thickness, mechanically fastened or adhered with hot mopping asphalt. Ply Sheet: — Two to four layers Type 15, G1 or G2, any combination. Surfacing: — Gravel. 2. Deck: NC Incline: 3 ASPHALT FELT SYSTEMS WITH HOT ROOFING ASPHALT Class A Insulation: — "ISO 95 +Composite °, "Rhoflex Isocyanurate Composite° or "ISO 95 +Wood Fiberboard Composite ", mechanically fastened or adhered with hot mopping asphalt, 1.5 to 3.5 In. thick. Insulation (Optional): — Perlite, 1 In. thick. PIy Sheet: — Three to four layers Type 15, G1 or G2, any combination. Surfacing: — Gravel, slag or crushed stone. 3. Deck: NC Incline: 3 Base Sheet: — °MB Base Sheet ", mechanically fastened or hot mopped. Insulation (Optional): — Any UL Classified (EPS must be covered with 1/2 In. thick min glass fiber, wood fiber or perlite), any thickness, mechanically fastened or hot mopped. Ply Sheet: — One or more layers ° MB Base Sheet " or Type G1, any combination. Surfacing: — Gravel, crushed stone or crushed slag, in a flood coat of hot roofing asphalt. 4. Dedt: C -15/32 Incline: 1 Insulation (Optional): — any UL Classified, any thickness. Ply Sheet: — One or more plies Type G1, G2 or "SBS Base Sheet °, mechanically fastened or hot mopped, any combination. Membrane: — °SBS Smooth °, °SBS Premium° or °SBS" (modified bitumen), hot mopped. Surfadng: — Gravel, crushed stone or crushed slag, in a flood coat of asphalt. 5. Deck: NC Incline: 1 - 1/2 Insulation (Optional): — any UL Classified, any thickness. PIy Sheet: — One or more plies Type G1, G2 or "SBS Base Sheet ", mechanically fastened or hot mopped, any combination. Membrane: — "SBS Smooth ", "SBS Premium" or "SBS" (modified bitumen), hot mopped. Surfacing: — Gravel, crushed stone or crushed slag, in a flood coat of asphalt. 6. Deck: NC Incline: 3 Insulation (Optional): — Firestone "ISO 95 +GL ", "FlberTop B ", "C ", "E ", "S ", wood fiberboard, polyisocyanurate, fiberglass, periite, any combination, any thickness, mechanically fastened, hot mopped or attached with any UL Classified cold adhesive. Base Sheet (Optional): — One or more plies Firestone "MB Base Sheet °, mechanically fastened or hot mopped. PIy Sheet: — One or more plies Firestone °Ply IV Felt° or "Ply VI Felt °, mechanically fastened or hot mopped. Surfadng: — Gravel, crushed stone or crushed slag in a food coat of asphalt. 7. Deck: C -15/32 Incline: 3 11/iA /1nin i').')Q FGFU.R9516 - Roofing Systems file: / / /C: /Users/ Jose / Documents /Work%20 %23 %202 %20(Miam 72. Deck: NC Incline: 1/4 Insulation: — Perlite, glass fiber or wood fiber, 3/4 to 2 in. Membrane: — °FR- EPDM ", °W -EPDM" or "G- EPDM °, 45 or 60 mil, fully adhered to insulation with Uniroyal °Royal M6504" roofing adhesive at 1 gaVsq. 73. Deck: NC Incline: 1/4 Insulation: — Glass fiber, perlite or wood fber, 3/4 to 2 in. Membrane: — "EPDM" or "Triumph EPDM ", 45 or 60 mil. 74. Deck: NC Incline: 1/2 Insulation: — EPS, any thickness, covered with USG °Structodeck ", 1/2 to 1 in. Membrane: — °FR EPDM", 45 or 60 ma. 75. Deck: NC Indine: 1/2 Insulation: — Polyisocyanurate, any thickness. Barrier Board: — Wood fiberboard, 1/2 in. min. Membrane: — "W- EPDM ", "R -EPDM" or °Triumph Reinforced EPDM", 45 or 60 mil, fully adhered with Uniroyal °Royal M6504° adhesive at 75 sq ft/gal. The membrane laps are sealed with Uniroyal °Royal M6365° adhesive at 1/2 gal /100 sq ft and the lap edges are caulked with Uniroyal "Royal M6389 ". 76. Deck: NC Indine: 1/2 77. Deck: NC Insulation: — Polystyrene, any thickness. Barrier Board: — Wood fiberboard, 1 in. min, or one of the foibwing boards at 1/2 in. min: Celotex wood fiberboard, Georgia- Pacific °Sturdi -Top° or Huebert Fiberboard fiberboard. Membrane: — "R -EPDM " or "Triumph Reinforced EPDM", 45 or 60 mil, fully adhered with Uniroyal 'Royal M6504" adhesive at 75 sq ft/gal. The membrane laps are sealed with Uniroyal "Royal 6365° adhesive at 1/2 gaV100 sq ft and the lap edges are caulked with Uniroyal 'Royal M6389 ". Indine: 1/2 Insulation: — One of the following (any thickness): 1. Atlas Roofing "ACFoam II°. 2. Apache Products "Apache PYROX °, "Apache White Line ", 'Apache Tapered Pyrox ". 3. Johns Manville "ENRGY 2A °, °ENRGY 2G ". Membrane: — "FR° EPDM, 45 to 60 mils, fully adhered with one of the following: 1. Uniroyal bonding system. The membrane is adhered with *Royal M6504" bonding adhesive, applied at 60 sq ft/gal. The membrane laps are sealed with "Royal M6365° lap adhesive, applied at 75 sq ft/gal. The lap edges are caulked with °Royal 6346 ". 2. Ashland Chemical bonding system. The membrane is adhered with "PIIOBOND 2375 bonding adhesive, applied at 60 sq ft/gal. The membrane laps are sealed with °PLIOBOND 9053° lap adhesive at 131 Iin ft/gaL The lap edges are caulked with °PLIOBOND 5533 ". 78. Deck: NC Indine: 1/4 Insulation: — Polystyrene or polyisocyanurate, any thickness. Barrier Board: — Wood fiberboard, 1 in. min, or one of the following boards at 1/2 in. min: Celotex wood fiberboard, Georgia- Pacific "Sturdi -Top° or Huebert Fiberboard fiberboard. Membrane: — °EPDM °, 45 to 60 mil, fully adhered with Uniroyal "Royal M6504" adhesive at 75 sq ft/gaL The membrane laps are sealed with Uniroyal °Royal M6365 " adhesive at 1/2 gal /100 sq ft and the lap edges are caulked with Uniroyal °Royal M6389 °. 79. Deck: C -15/32 Indine: 1/2 Insulation (Optional): — Perlite or glass fiber, 15/16 in. thick min, or polyisocyanurate, 2 in. thick min, joints in insulation offset 6 In. with joints in deck. Base Sheet: — Two or more plies "MB Base Sheet" (Type G2) or any Type G2 weighing a min of 23 lbs/sq, mechanically fastened, spot or fully mopped. Ply Sheet (Optional): — 'APP 160° or °APP 170° (modified bitumen), heat fused. Membrane: — "APP 180 FR° or "RhoFlex FR" (modified bitumen), heat fused. 80. Deck: NC Indine: 1 Insulation: — Polystyrene (1 to 2.5 lbs/cu/ft), 1 in. min. Slip Sheet: — Atlas Roofing "FR -10 ". Membrane: — "UkraPiy° (TPA), 40 -100 mIL 81. Deck: NC Indine: 1 Insulation: — Perlite, any thickness. Membrane: — °UltraPly" (TPA), 40 -100 mil. 82. Deck: NC Incline: 1 -1/2 Insulation (Optional): — Polystyrene (tapered or uniform thickness) or Dow - Chemical "Styrofoam LG, PD, RM, SM, TG or STYROIB° , any thickness or glass fiber, any thickness. Insulation: — Wood fiber (Huebert) 1 in. or ° FiberTop 8 ", • FiberTop E ", "FiberTop C° or "FiberTop S ", 1/2 in. min. Membrane: — "UitraPy" (TPA), 40 -100 mil. 83. Deck: NC Indine: 1 Insulating Concrete: — Deck covered with either of the following insulating concretes (poured In place): cellular, vermiculite, perlite, gypsum or structural. Optionally, a base concrete deck may be used If ail exposed surface joints are grouted. Membrane: — °UltraPy° (TPA), 40 -100 mil. 84. Deleted. 85. Deleted. 86. Deck: C -15/32 Indine: 1/2 Insulation (Optional): — Perlite or glass fiber, 15/16 in. thick min, o:(polyisocyanurate, 2 b. thick min in insulation offset 6 in. with joints In de - embrane: — "APP 180 FR" (modified bitumen), heat fused. 87. Deck: NC Indine: 1/4 Type G2) or any Type G2 weighing a min of 23 lbs/sq, mechanically fastened, spot or fully bitumen), heat fused. 13 of 37 11/16/2010 12.7R P