Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
RC-10-726
Inspection Number: INSP - 141814 Permit Number: RC -4 -10 -726 Scheduled Inspection Date: December 02, 2010 Inspector: Bruhn, Norman Owner: SMITHERMAN, DAVID Job Address: 570 NW 112 Street Project: <NONE> Contractor: ADVANCE SOLAR & SPA INC Building Department Comments INSTALL SOLAR DOMESTIC HOT WATER HEATER SYSTEM Passed f /04, Failed Correction Needed Re- Inspection Fee No Additional Inspections can be scheduled until re- inspection fee is paid. Inspector Comments cv December 01, 2010 Miami Shores, FL 33138 -0000 Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 For Inspections please call: (305)762 -4949 Permit Type: Residential Construction Inspection Type: Final Roof Work Classification: Solar Phone Number Parcel Number 3021360210620 Phone: (954)938 -8507 Page 5 of 22 5(1\i' CaCVi t Poti, g- Buildin g Department artment BUILDING PERMIT APPLICATION FBC 2004 Permit Type (circle): Building Roofing Miami Shores Village 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 Master Permit No. Owner's Name (Fee Simple Titleholder) teell d V W ► ertan Phone # Owner's Address 0 t61 ({ 2. E Cit m; cxynl S ? S State . 1U► e d-c Tenant/Lessee Name Architect/Engineer's Name (if applicable) Value of Work For this Permit $ Type of Work: ['Addition 11 Describe Work: 1 f stm zip 33 J to Phone # Permit No. T 0 -19 L.V 305 -q Job Address (where the work is being done) 570 N(A) HO_ 1 S-+-v -ef± City Miami Shores Village County Miami -Dade Zip 3: ;J l0 X FOLIO / PARCEL # 1 1 — G 1 J - 02_ ` - (p2_0 Is Building Historically Designated YES NO Contractor's Company Name AeA Van C S t I � 4 S Pa Contractor's Address qq0 NIA) 5 3 V-)- City derdOJ L State Qualifier Name Br) a1) 610 ci 4 K fir phone #1.4 �q3� ' 4sd 7 State Certificate or Registration No. (2 'J� 540 L 4 Certificate of Competency No. Phone # q 93 Os 7 Zip '33 c9 Phone # r ownq Z 7 zoo BY: ........ 5 37(,, Square / Linear Footage Of Work: DAlteration New ❑ Repair/Replace ❑ Demolition 1 scfay domes+E h(Yt u i-eY S k-k_nn. * *, ***** ** *** * * ** * *,t*** * * * * *** **** * * ** F ees ** * * **** *** * * *** ** * * * ** * ** *** * ** * ** * * ** * ** Submittal Fee $ Permit Fee $ /Da 4 .- 1 ?-- CCF $ 1 '6k Notary $ Training/Education Fee $ 0 -4O Technology Fee $ Scanning $ Radon $ DPBR $ Bond $ Code Enforcement $ Double Fee $ Structural Review. $ Total Fee Now Due $ i 1aao ww CO/CC Zoning $ See Reverse side -+ Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged Sign: Owner or Agent The foregoing instrument was acknowledged before I'T 1 efore this - day of i) , 20) ® b j),vl C� , r� Y I elem , who isi ersonally known�to me or who has produced As identification and NOTARY PUBLIC: Art Print: 1401 My Commission Expires: (® 11 I 1 1 . AMY S k t MY COMMISSION # DD728016 • EXPIRES October 23, 2011 c I nndallotarYSern *, *, , *** * , , , , , *** ** *, , , , *, , , err , , , *, , , , ***a *** * a ir, , , , , , , * , ** **** *** *rr*** ** *** * * *** * ***** APPLICATION APPROVED BY: (Revised 07/10/07) Signature Contractor The foregoing instrument was acknowledged before me this y � day of i�� 1 , 200_, by &l ay) 6019b✓f3 who is ersonally knoo me or who has produced J as identification and who did take an oath. ,sn 6bj AMY STARR NOTARY PUBLIC: }= MY COMMISSION # DD728016 :��� ror EXPIRES October , 2011 I F�L i`' + ^, �londallota Id a Sign: Print: My Commission Expires: j Plans Examiner Engineer a Zoning THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. AGGREGATE LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSRADD'L LTR A NSRC GENERAL X TYPE OF INSURANCE LIABILITY COMMERCIAL GENERAL LIABILFTY POLICY NUMBER GL00048884 POLICY EFFECTIVE DATE i,, •0 11/08/2009 POLICY EXPIRATION DATE i. i; +i... LIMITS EACH OCCURRENCE $ 1,000,000 11/08/2010 PR MISES (Ea occurrence) $ 100,000 Mimi Shores, FL 33138 CLAIMS MADE X l OCCUR MED EXP (My one person) $ 5,000 PERSONAL & ADV INJURY $ 1,000, 000 GENERAL AGGREGATE $ 2,000,000 GEM_ AGGREGATE LIMIT APPLIES PER: 7 POLICY n JjEC• n LOC PRODUCTS - COMP /OP AGG $ 2,000,000 B AUTOMOBILE X X X ANy AuT0 ALL OWNED A OS SCHEDULED AUTOS HIRED AUTOS NON -OWNED AUTOS CA00138591 06/22/2009 06/22 /2010 COMBINED SINGLE LIMB (Ea accident) $ 1,000,000 BODILY INJURY (Per person) BODILY INJURY (Per accident) PROPERTY DAMAGE (Per eccdent) $ GARAGE LIABILITY ANY AUTO AUTO ONLY - EA ACCIDENT $ OTHER THAN EA ACC $ AUTO ONLY: AGG $ EXCESS /U9BRELLALIABWTY OCCUR CLAIMS MADE DEDUCTIBLE RETENTION $ EACH OCCURRENCE $ AGGREGATE $ $ $ $ WORKERS COMPENSATION AND EMPLOYERS' LIABILITY ANY PROPRIETOR/PARTNER/EXECUTIVE Y!N OFFICER/MEMBER EXCLUDED? (Mandetory N NH) If yes, describe under SEC S PEC IAL PROVISIONS below I TORY LIMITS I I ER E.L. EACH ACCIDENT $ E.L. DISEASE - EA EMPLOYEE $ E.L. DISEASE - POLICY LIMIT $ OTHER DESCRIPTION OF OPERATIONS! LOCATIONS /VEHICLES !EXCLUSIONS ADDED BY ENDORSEMENT SPECIAL PROVISIONS ------- - - - - -- SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, THE ISSUING INSURER WILL ENDEAVOR TO MAIL 10 DAYS WRITTEN NOTICE TO THE Cris! inICATE HOLDER NAMED TO THE LEFT, BUT FAILURE TO DO SO SHALL IMPOSE NO OBLIGATION OR LIABILITY OF ANY KIND UPON THE INSURER, ITS AGENTS OR Miami Shores Village Building Department REPRESENTATIVES. 10050 NE 2 Ave. AUTHORIZED REPRESENTATIVE Mimi Shores, FL 33138 Reed Herndon /CYNDI ' LLl Date: 4/23/2010 Time: 9:26 AM To: 19549386949 ndon Carr & Co. Page: 001 ACORD, CERT UC PRODUCER 239.939.1996 Herndon Carr & Company 10501 Six Mile Cypress Pkwy Suite 101 Fort Myers, FL 33966 -6400 FAX 239.275.0276 INSURED Advance Solar & Spa, Inc. DBA: 5 County Wholesale Distributors 2431 Crystal Dr. Fort Myers, FL 33907 IFICATE OF LIABILITY INSURANCE THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. INSURERS AFFORDING COVERAGE INSURER A FCCI Commercial Ins. Co. RS: INSURE National Trust Insurance Co INSURER C: INSURER 0: INSURER E: DATE (MMIDD/ YYY) 04/23/2010 NAIC # 33472 20141 COVERAGES ACORD 25 (2009101) LLATION The ACORD name and logo are registered marks of ACORD @ 1988 -2009 ACORD CORPORATION. All rights reserved Her 05/26/2010 09:57 FAX 1 800 685 7530 DATA SCAN FIELD SERVICES Z001/001 Check type of Solar System to be installed: Solar Thermal ❑ Solar Electrical ❑ Solar Hybrid Required Inspections: Required Inspections: Required Inspections: Plumbing Solar Final Electrical Solar Rough Electrical Solar Rough Electrical Solar Final Electrical Solar Final Electrical Solar Final Structural Solar Final Structural Solar Final Plumbing Solar Final Structural Solar Final Owner Notification: Installation of roof mounted photovoltaic or solar support systems typically require roof system Penetrations to allow attachment to the structure which may create additional long -term roof system maintenance requirements and/or jeopardize roof system manufacturer's warranties. Roof mounted solar systems generally required removal and reinstallation of solar panels /arrays in order to perform routine roof system maintenance, repair or replacement. I hereby acknowledge that I have read and understand the above notification on this day of IY)I ,2010 Print owner name �� 1 1 i {� L Owner signature Property adddress , Miami Shores, FL Permit # PL L1 -Ib °- )14 AMY STARR •b. MY COMMISSION # DD7280 2011 'ern ��b°,- EX PIRES October 23, 'en71 -0 Flondallotaryservic Solar Installation Requirements Notary stamp Print Notary Name r zva ,v 2 MO Miami Sh . - illage Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 Gi37 —L-9`11 0 0 o_ w 0 E. w m O w U z 0 U z 0 0 0 z > z 3 O N F- O z LL z O z 0 z w 0 z w > 0 w 0 z Q er O N w w zN¢ w p z „z0 0 0 0 7 0 O aw •- U ' z n � J V Z w UJ w . - Z u- u- w Z - w y > z O c'U • •• 000 • SOLENE MOUNTING BRACKET W/ LAG BOLT AS SHOWN BELOW / 2' / PLAN OF COLLECTORS SCALE: 3/16 " =1' -0" SOLENE MOUNTING BRACKET W/ LAG BOLT AS SHOWN BELOW SOLENE BRAND COLLECTOR• HIP ROOF END CONDITION ROOF ZONE 3 CORNERS 4. WIND TUNNEL TEST DATA FOR THESE CONNECTIONS AND ASSEMBLIES HAS BEEN AVAILABLE THROUGH HELIOCOL, INC. WIND LOAD CALCULATIONS ARE AVAILABLE 5. ALTERNATIVELY SOLENE MOUNTING BRACKET CAN BE FASTENED TO THE SOLENE SELF TAPPING SHEET METAL SCREWS. HIP ROOF GENERAL CONDITION COLLECTORS SHALL NOT BE INSTALLED IN "CORNER ZONES" AS SHOWN ON DIAGRAM SOLENE BRAND COLLECTORS LONG DIMENSION SOLENE BRAND COLLECTOR RIDGE GABEL END ROOF CONDITION ROOF CONER ZONE SHALL BE 10 PERCENT OF SHORT DIMENSION OF BUILDING, OR 40 PERCENT OF MEAN ROOF HEIGHT, OR 7 FT - WHICH EVER IS SMALLER. ROOF LAYOUT PLAN SCALE: NONE GENERAL NOTES: 1. COLLECTOR CONNECTIONS SHOWN HAVE BEEN DESIGNED TO RESIST WIND LOADS OUTLINED IN THE 2007 FLORIDA BUILDING CODE, AND 2009 SUPPLEMENT, CHAPTER 16 FOR 146 MPH EXPOSURE "C" WIND VELOCITY AND PER ASCE 7 -05, CHAPTER 6.0 FOR 146 MPH EXPOSURE "C" WIND VELOCITY TYPICALLY. 2. LAG BOLT CAPACITIES AND EMBEDMENTS ARE BASED UPON "NATIONAL DESIGN SPECIFICATION FOR STRESS GRADE LUMBER AND FASTENINGS" AS PUBUSHED BY THE NATIONAL FOREST PRODUCTS ASSOCIATION. APPLY ROOF GRADE SEALANT TO ALL CONTACT SURFACES. 3. ALL CONNECTIONS ARE FOR ROOFS 0' TO 45' MAX SLOPE CONDITIONS. ALL CONNECTORS ARE FOR MEAN ROOF HEIGHTS NOT TO EXCEED 30' -0 ". COMPILED BY TEXAS A &M UNIVERSITY, COLLEGE STATION, TX. AND IS THROUGH HEUOCOL, INC. REPORT #SL -3. COLLECTOR WITH EITHER (1) " STSTL BOLT AND NUT, OR (2) Ya" SOLENE MOUNTING BRACKET ROOF SHEATHING 4 1 5 5_ NVv • •W� • •. • •4• • • • S At • • SOLENE BRAND COLLECTOR %" DIA S NLESS STL LAG BOLTS AT EACH SOLENE BRAND CONN TYP. NOTE: ROOF FINISH ,.. OMITTED FOR CILARITYY • • • • • ' s I ISSN tRU SS SOLENE • k • BLAND NAILER INST. .7 SC,AL€ • 1 1 /2 " =1' -0" • • • • • • • SOLENE MOUNTING BRACKET ROOF SHEATHING %" DIA STAINLESS STL LAG BOLTS AT EACH SOLENE BRAND CONN TYP. NOTE: ROOF FINISH OMITTED FOR CLARITY SEE NOTE 3 WOOD TRUSS SYSTEM #2 SYP OR BETTER METAL B UP ROOF SCALE: 1 -1 /2 " =1' -0" SOLENE BRAND COLLECTOR FLAT CONCRETE TILES ROOF SHEATHING %" DIA STAINLESS STL LAG BOLTS AT EACH SOLENE BRAND CONN TYP. SOLENE MOUNTING BRACKET AND STAND OFF ASSY SOLENE BRAND COLLECTOR WOOD TRUSS M #2 SYP OR BETTER NOTE: CUT OUT OR REMOVE TILE TO INSTALL STANDOFF ASSY. THEN REINSTALL TILES AROUND MOUNTING HARDWARE FLAT CONC. TILE ROOF SCALE: 1 -1 /2 " =1' -0" 3 "X3 "X71;" THK 3" L 6063T6 ALUM SORTS WITH 1 "DX) " THK 2% L ALUM TUBE INSERT BOTH ANODIZED SOLENE BRAND MOUNT STAND OF SCALE: NTS SSY SOLENE MOUNTING BRACKET 2x PT OR UNISTRUT CONTINUOUS ALONG PANEL FOR MOUNTING W/ 3/8" ST STL ALL-THRD ROD W/ NUT & WASHER EA END - PROVIDE "LOCTITE" AT ALL NUTS. CENTER RODS @ 3' -0" o/c MAX SPACING MISSED TRUSS SOLENE BRAND SPANNER INSTALL SCALE. NTS SOLENE BRAN COLLECTOR WOOD TRUSS SYSTEM #2 SYP OR BETTER WOOD TRUSS SYSTEM #2 SYP OR BETTER SOLENE MOUNTING BRACKET AND STAND OFF ASSY SOLENE BRAND COLLECTOR %" DIA STAINLES STL LAG BOLTS AT EACH SOLENE BRAND CONN TYP. NOTE: CUT OUT OR REMOVE TILE TO INSTALL STANDOFF ASSY. THEN REINSTALL TILES AROUND MOUNTING HARDWARE BARREL TILE ROOF SCALE: 1 -1 /2 " =1' -0" BARREL TILES • • •• • • • • ••• •• •• • • g . 01 4 .L) PROJECT 11: DESIGNED: REC111309 SCALE. NOTED DRAWING NO. SL -3 SHEET 1 OF 1 S'U JLC T iO OCivi; STA I E AND CC UN CY ���� ��� • 2381 Crest Ridge Crt Sanford, FL 32771 407 -474 -9181 Fax 407 -688 -1898 •. ..• • • • • • • • • • •• ••• • • •• • • • • • • • • • • • • • • • • • • • • • • • • • •• • • • • • • •r• I. Designed in Accordance with ASCE 7 -05 with the following factors: II. Velocity Pressure: Components and Cladding Figure 6 -3 (ASCE 7 -05) yields III. Force on Collector IV. Required Lag Bolt penetration in wood trusses. • • •• • • .••• • • • • • • • • • • • • • • ••• • • • • ••. • • • • • . • • • • • • • •••• • • • • • •••• • •• • •• • • • • • •• • • • • • Residential, Commercial, Multi - Family Consulting Engineering 1. Wind Speed = 146 MPH 2. Wind Importance Factor (I) = 1 3. Wind Exposure = C, Z = 30 ft., Case 1 Zone 1 1. N = -36 psf (Roof pitch 0 to 7 degrees) 2. Exposure C conversion 1.40 3. modified pressure coefficient: q = -50.4 psf Zone 2 1. pnet3o = -55 psf (Roof pitch 0 to 7 degrees) 2. Exposure C conversion 1.40 3. modified pressure coefficient: q = -77 psf Total force on collector will be as follows: Zone 1 A = 4'x10' = 40 ft F = 40 x -50.4 = 2,016 lbs Zone 2 A 4'x10' =40 ft F2 = 40 x -77 = 3,080 lbs RC Engineering, LLC Wind Loading Calculations (Report #SL -3) Domestic Hot Water System 1. Force on individual lag bolt = lifting force — conservative approach) / 4 Zone 1 • F1= 2,016 lbs/ 4 = 504 lbs Zone 2 • F2= 3,080 lbs/ 4 = 770 lbs RC Engineering, LLC 407 - 474 -9181 FAX 407 -688 -1898 WOR 1 111 64 collector weight (lpc lef tAtar s w j s • SA' i So L Ly • A • • • • • •• ••• • • • • •• • • • ••• •• • • ••• • • • • • • • • • • • • • • • • • • • • • • • • •• ••• i•• • • If you have any questions or require additional information, please feel free to contact me. E. (Rick) Castillo, P.E. FL License #52590 • • •• • • • • • • • •• • • • • • ••• • • 2. Withdrawal load of 3/8" lag bolt in Southern Pine with 3" min penetration = 803 lbs => OK (Per 2005 NDS) • • • • • ••• • • • • ••• • • • • • • • • • • • • • • ••• • • • • •.••• • • • • • • •• •• • • • •• •• .•• • • • ••• • • RC Engineering, LLC Residential, Commercial, Multi - Family Consulting Engineering RC Engineering, LLC 407-474-9181 FAX 407 -688 -1898 a � q 'u�u�nn n ,� . " p' . CAS . ece 55 p, si t .s • • • i Z VS 11() APR 202010 (�1 ( )) c L� [t. u; L (Vv01/4.47.. 7 iccc t.L -t`T5 S Lce c. 5 T-NnS i wve .51 sie im ah s1to lH. rte , we �,1i coo o h a o 11 ust o- "('',e`t` '5e- �G��car .Q �1 me bti52 SQ 0,V ti. SUMMARY INFORMATION SHEET FLORIDA SOLAR ENERGY CENTER 1679 CLEARLAKE ROAD, COCOA, FLORIDA 32922 -5703 (321) 638 -1000 Solene 927 Fern Street, Suite 1500 Altamonte Springs, Florida 32701 This solar collector was evaluated by the Florida Solar Energy Center (FSEC) In accordance with prescribed methods and was found to meet the minimum standards established by FSEC. This evaluation was based on solar collector tests performed at the Florida Solar Energy Center, Cocoa, Florida. The purpose of the tests is to verify initial performance conditions and quality of construction only. The resulting certification is not a guarantee of long term performance or durability. Gross Length Gross Width Gross Depth Gross Area Transparent Frontal Area Volumetric Capacity Weight (empty) Recommended Flow Rate Test Pressure Number of Cover Plates Flow Pattern Number of Flow Tubes Enclosure Glazing Absorber Absorber Coating Insulation Tested per ASHRAE 93 -1986 Incident Angle Modifier K = 1.0 - 0. 19 (—L-1) case Efficiency Equations n= 74.0 - 540 (Ti -Ta)/1 n= 70.8 - 170 (Ti -Ta)/I - 5290 [(Ti- Ta) /I] Units of (Ti -Ta) /I are °C / Watt/m MANUFACTURER Revised October 2006 DESCRIPTION 3.096 meters 10.16 feet 1.202 meters 3.94 feet 0.098 meters 0.32 feet 3.722 square meters 40.06 square feet 3.469 square meters 37.34 square feet 3.8 liters 1.0 gallons 68.9 kilograms 152.0 pounds 44 mils 0.7 gpm 1103 kPag 160 pslg One Parallel Forced circulation Fourteen MATERIALS Aluminum frame, plastic back Tempered low iron glass, 0.32 cm thick Copper tubes welded to copper fins Black chrome selective coating Foil faced polyurethane, 3.2 cm thick; Mineral wool, 1.9 cm thick THERMAL PERFORMANCE RATING n= 74.0 -95 n= 70.8 - 29 June 2004 FSEC # 001390 Collector Model Solene \Chromagen SLCR -40 (TI -Ta) /1 (Ti -Ta) /1 - 164 [(Ti- Ta) /1] Units of (Ti -Ta) /I are °F / Btu/hrft The collector has been rated for energy output on measured performance and an assumed standard day. Total solar energy available • 4er the rardgrctfia,y it 5045 Watt hours/m (1600 Btu/ft distributed over a 10 hour period. • putpytrn@ ?olIector based on the second -order efficiency curve are: • • • • • i � l • 'C o ?lecto t' T a ` nature Energy Output, ti � LoW `Tem e ature, 35 °C (95 °F) 45,400 Kilojoules /day 43,100 Btu /day m {alga, 50 °C (122 °F) 37,100 Kilojoules /day 35,200 Btu /day h ,*e t re, 100 °C (212 °F) 7,700 Kilojoules /day 7,300 Btu /day 1 0.22` 1� tip f° -;t ••• • `r,€ �.' . Ts.: -:. • • • • • • • • • • • • •.• • • • • • • • • • • • • • .• 11 • • • 11 •• . •.• • 1 • • • •• FLORIDA SOLAR ENERGY CENTER 1679 CLEARLAKE ROAD, COCOA, FLORIDA 32922 -5703 (321) 638 -1000 Approved Solar Energy System FSEC # S9182 Solene 927 Fern Street, Suite 1500 Altamonte Springs, Florida 32701 This system was evaluated by the Florida Solar Energy Center (FSEC) in accordance with the Florida Standards Program For Solar Domestic Water and Pool Heating Systems (FSEC- GP -7 -80) and was found to meet the minimum standards established by FSEC. North The calculated Florida Energy Factors for this system are: 2.8 Description Collector Manufacturer Model Number Units Total Rating (Btu) 1. Solene Solene \Chromagen SLCR -40 1 35,200 2 3. 4. Tank Manufacturer Model Number Capacity (gal) 1. Lochinvar FTA -082K 80 2. Rheem 81RV80-1 80 3. 4. Pump Manufacturer Model Number Power Draw (Watts) Rated Power 1. El Sid SID5PV 5 1/100 H.P. 2. March 809- BR -24VDC 15 1/100 H.P. 3. 4. Controller Manufacturer 1. Solarex 2. 3. Freeze Protection DISTRIBUTOR 1. Freeze prevention valve 2. Manual drain down 3. Othet 1VIajpr;Clutporfents ••`• ••• •• • • • •• 2. • • • • • • • • • • • • • •• • • • • • • ••• • • • • • • • • • • • • • • • •• •• • • • • • • Model Number Type: Photovoltaic SA5 SYSTEM Approval Date: AUG 2006 Revision Date: MAY 2007 Solene \Chromagen 40PV South /Central 3.0 Type: Direct • •• • • • • . • • • • • • - If :yrtt e: ipfsIlnatio'h is tedluired you may contact the Florida Solar Energy Center at the above address. • • • ••• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •• • • • • • • • • •• • • • •• ••• • • • • • • • • • • • • ••• • • • • • • • • • • • • • ••• • • • COMMitat • • • • • • • • • • • ••• • • • • • • • ••• • • • • ••• • • • • • • • • • • • •• •• ••• • • SIITTeld liSotTINGELEIRNT INETUNTAT •• ••• • • • • • Oli FEED T G 7t 4 T COLLEZTOR plosiftE • • • • • David Smitherman 570 NW 112 Street Miami FL 33168 VOW Marcel G1 wz40r Izoazier puriM kg ra: praong unit bultd 1 qia ain:40r Imairta cirri erving oFeratiorm. Appriestainsinctirdo harm twattv 5ystAirm =CV heating artimm, heal rerdzioareariterrz rrd m0r0ulatIng teRiNV krt 5eirriC5VC ant carlE175FClili I hot were milks,. Cortivgl Uu festory roe spoteergef• 411K)1 OM! 61006 Welt aii4 54L6iXolti•i• maw. 000-PL-11 ARCH - 001 ,,,,,, kfq 4 kttefiT.6" 7 7 4 „ 140100101011a14 iaVe„, 04,114•0111W, I. 641M-413013, 444 id 04 - VAX:1114 ntt4tutit WitiVNARCHPUIVIA.00011 M. Flew Max Head 5 Sem 7 fi. So:17 pei gl0m AISBREVATIpN.S.: Pump haLirig SR is Emma PL is Peysulfil Plastic C is Carder Inlet • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • 121,24ViSt 413R &OWN. firiliseF'11ausina morel. atiqm 500-PL GENERAL RATINGS a SPECIFICATIONS I nlet MPT sta' 3ift FPT &IA' MPT moult 50.ax Inter Max liquid Pressure Terepereture . P INSTALLATIONS: The 5'59 Eeries pimp is assembled arai ready ter irStSllailion The purap s,Pauld b :Statatied With Me arrow on our housing pointing in the dreoliwi ot the water flew within the argent. 10 the arrow indleear19 eater Row le not iirt the direor.bri yOu require when the motor is in positim TE41174 the fear round 1=e171g1 EZreteVS t:11:errt 1 ding tie housing to Vi sir assembly ard rotate :Me housing assembly as required. :ac s tra tour =moment! .4: len The pump made w Of MT^ bask* sLihassambiles They am. the 'Mt End Assembly and the MotrOBrecket/DMie Magnet irribtry. Ta Z0F4Mit 1h 2 oreorrNios, %Imply riOnvve the 4 round Imad1,0Myw% (110m 1). Th0 pOtrOW1.1 Wan sopmenta irrIP rh 2 imb-4SsarliblieS, TIM v..210t vtiEE ptiD. b cooteinad *Min the Wet End atioientdy untat• you teroasin the %otews n the rent of: tha 1 Erid immtribly. GENERAL SAFETY INFORMATION: Fellow all local. eleotriW arid entity aides, a tyi the Metibstional :le*. rani Walls Ast KISHPAo. Make oerlart that Ui poLsier warm nroblrseneMs of your equipment Aways dirafirirtinevet sp:43 pet% periormiris any 'Nark on or near ',It's *loom *WWI. CetAranorTiist tie emit to relieve eny pressure in Me eyetem arid i draining hot waterfront the NMI. or the sretem • • • • • • • 1. fLE10:464 5 for water ,ray. Victors ore • • U.L•Yelltietiail I$d, irdoettaritili ilttisese4 ef thermal rivOrkmdl • . dialliteEivertio uitito• U L•10 E&054 UMP 50 i 200'"F 121*C 809 12 & 24 VDC "MAGNEBOOST" HOT WATER PUMPS 12.024 000-13.1%00, 509.PL4 cer Islet 01oesing 2 VJ 4I Pack krt.4111 Length Vit 331 m 50 4.56 8 0.04 3.3 41,50 &woo 5.5 IN. 410 , 7,113 4.0 ttei. T 4,, • WO U1WL MY 201, . • .• • INK.TOR RATINGS f.4.SPECiFliCATIONGT Valls ti100 t ia 12 00 .. 7 , s DC 0.55 • • • • • • • • • • • • • • .*: • 114 • • • • • • • • • or. • • • • • • • • • • • • • • AE Small Photovoltaic Modules The AE 10) and AE-20J photovoltaic modules provide cost-effective photovoltaic power for DC loads with moderate energy require- ments. With VI single crystal Is in series., they charge batteties efficiently in virtually any climate. Both sints are laminated behind tempered glass with aluminum frames. Typical commercial appli- cations of these modules, include remote telemetry, instrumentation systems, security sensors, signals, and land-based navigation aids. Both modules have a gasketed junction box with two small holes for wire leads. These modules have a 10 year power output warranty. Made in China. UL listed. Pak Power Peak power valtaaa Peak power current Nominal voltage Length Width • • • • !" 4 • • ,zr„.- Bringing Power to the • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • 11 Vietts Volts Volts 12 Inches (11i m 24 46 0621 Inches (mm” . 17 7 t382j F.IP. HIC t.:1) pie .Since l 979' 20 173 1156 Redway Drive - Box 339 Redway, CA 95560 Phan (707) 923-2277 Fax (107) 923 vow& r •••"$• • AAW ‘ \-• A\I PART NUMBER: DESCRIPTION: CONSTRUCTION: APPROVALS: APPLICATION: Construction Parameters: Conductor Stranding Insulation Material Insulation Thickness Insulated Conductor Diameter Number of Conductors Lay Length Jacket Material Jacket Thickness Overall Cable Diameter Approximate Cable Weight Flame Rating Electrical Properties: 51104 18/2 STRANDED CMR/CL3R/FPLR FT4 CABLE This cable consists of two bare copper insulated conductors with an overall extruded jacket. UL Standard 13 and 444, NEC Articles 725 and 800. Class 3 Power Limited Circuit Cable and Communications Cable for Riser Applications Temperature Rating Operating Voltage Capacitance Between Conductors @ 1 KHz Capacitance Between Conductors to Shield © 1 KHz DC Resistance per Conductor @ 20 ° C Insulation Colors Jacket Color COLEMAN CABLE 51104 18 AWG 2/C C(ETL) US (ETL CODE) TYPE Legend (Surface Ink Print) CMR/CL3R/FPLR 75C SUN RES - TYPE CMG FT4 This product complies with European Directive 2002/95/EC (RoHS) On spedel orders, the customer will accept all factory lengths and +1 -10 percent of total order requested. Cable has a rip cord for easy jacket removal. The jacket is sequentially footmarked. The information presented here is, to the best of our knowledge, true and accurate. Since conditions of use are beyond Coleman Cable's control all product data presented is for informational purposes only and does not create a binding obligation or liability on Coleman Cable or confer any rights on any customer. The sale of products(s) Is conditioned upon acceptance of a purchase order subject to Coleman Cable's standard terms and conditions contained therein, including without limitation Coleman Cable's standard warranty. Coleman Cable disclaims all liability in connection with the use of information contained herein or otherwise. This specification is proprietary intellectual property of Coleman Cable. Any information contained herein shall not be disclosed to any party without written consent of Coleman Cable. Customer Name Date Signed Customer Approval •• ••• • • • • • ••• Specific'�tion Issu4 D�t� :Jude 38,/047 • • •• • • • • ••• • • •• ••• •• • • • •• • • • • • • • • • • • • • ••• • • • • • • • •• •• • • • • • • • • • • • • • • • ••• • • • • • • • • • • • • • • • • • • • • • • • •• • • • • • 0 • • • • • • 1-800- 323 -9355 (Phone) Designed By: PEP 1-847 -689 -1192 (Fax) 51104 o 2007 Coleman Cable, Inc. • • • • • • • • • • • • • • • • ••• • • 18 AWG Bare Copper 7/.0152" Foam Polypropylene 0.006" Nom. 0.057" Nom. 2 5.00" Nom. PVC 0.014" Nom. 0.142" Nom. 16.7 Lbs/1M' Nom. UL 1666 Riser Flame Test -20 ° C to 75 ° C 300 V RMS Max. 24 pF /ft Nom. 6.29 Ohms/1M' Nom. PRODUCT DATA SHEET Controlled Document - Engineering Drive Black Red White, Gray, Brown, Beige (Other colors available for minimum order) 1530 Shields Drive Waukegan, IL 60085 Toll -Free (800) 323 -9355 Fax: (847) 689 -1192 Cable Cross - Section Scheduled Inspection Date: November 24, 2010 Inspector: Hernandez, Rafael Owner: SMITHERMAN, DAVID Job Address: 570 NW 112 Street Project: <NONE> Miami Shores, FL 33138 -0000 Contractor: ADVANCE SOLAR & SPA INC Building Department Comments November 23, 2010 Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Inspection Number: INSP - 141697 Permit Number: PL -4 -10 -714 For Inspections please call: (305)762 -4949 Permit Type: Plumbing - Residential Inspection Type: Final Work Classification: Solar Phone Number Parcel Number 3021360210620 Phone: (954)938 -8507 INSTALL SOLAR DOMESTIC HOT WATER SYSTEM Passed Failed Correction Needed Re- Inspection Fee No Additional Inspections can be scheduled until re- inspection fee is paid. Inspector Comments Page 4 of 27 BUILDING PERMIT APPLICATION FBC 2004 Permit Type: Plumbing Owner's Name (Fee Simple Titleholder) Owner's Address 570 N (A) 1 I S Cit Naafi S State Flo (Via- Tenant/Lessee Name E -MAIL: Type of Work: ❑Addition ['Alteration Describe Work: ) 1,\ I , 0 Submittal Fee $ 3 '00 Permit Fee $ Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 Job Address (where the work is being done) . /v L.) 1 12 . City Miami Shores Village County Miami -Dade Zip FOLIO / PARCEL # 1 1 °' 2 - 02 1 - b( Z 0 Is Building Historically Designated YES NO X Contractor's Company Name j4dv {j alai 4 )p0_ Phone # 6 15 -1 -4 -- )7 Contractor's Address 9 At m) 53 str ?e+ City F1 f.,C.l rie-I/U• State 1/C ‘P/Ciric0. Zip a3 09' Qualifier Name BY ely] c -n 1d I r 4 Phone #9s -93Se- O State Certifi ate or ' - :_1str No. �C (�sLo ' (p E -MAIL: �� // '' i1 / / fray/ Architect/Engineer's Name (if applicable) Phone # Value of Work For this Permit $ **** *** ****** ***** *** ** * **** , *, F ees **** ************** ** ** ***** ******** ***,., *** CCF $ 1 ' I / CO/CC Training/Education Fee $ Technology Fee $ ,J Notary $ 11 Scanning $ (Q'(J Radon $ Bond $ Code Enforcement $ Square / Linear Footage Of Work: 46,New ❑ Repair/Replace ❑ Demolition d u rnP h p+ l,Ua fie,✓ sy(S-le,m • DPBR $ Permit No. Master Permit No. Zip 3 2) L0 Y Phone # 1003EVED APR 2 7 2070 WI BY: .... .... P\ 10-11 Phone # 305 -!- Q — 5 ca 33/ l� Certificate of Competency No. Zoning $ Double Fee $ Structural Review. $ Total Fee Now Due $ � G �J q I ' OA0 See Reverse side -) Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged Owner or Agent The foregoing instrument was acknowledged before me this 13 day of y I , 20 10, by _NL6CL6laithet who is ersonally known o me or who has produced As identification and who tY P`�•., AMY STARR MY COMMISSION # DD728016 w .�- EXPIRES October 23, 2011 NOTARY PUBLIC: Sign: Print: \1 £'li'a,Vr ( APPLICATION APPROVED BY: (Revised 02/08/06) Flond allotaryService.com Signature Contractor The foregoing instrument was acknowledged before me thisZ3 6 day of I I , 20 JO , by who i era nally kno to me or who has produced as identification and who did take an oath. NOTARY PUBLI Sign: Print: (. 4 N5 -- -- Aetkar d 'Ws AMY STARR MY COMMISSION # DD728016 EXPIRES October 23. 2011 !Wail .,.4. S.'= rv1Ce.COm 10 23 Ia My Commission Expires: 1 0 4 j is) ! My Commission Expires: * * * * * * * * * * ** * * * * * * * * * * ** * * * ** ******************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** * * * * * * * * * * * * ** Plans Examiner Engineer Zoning