Loading...
ROOFINGType Insp'n Permit No. Name MIAMI SHORES VILLAGE BUILDING DEPARTMENT 305- 795 -2204 Building Inspection Request Date 3 -ea., Time -- tie )2 f Abe -s II 6'4' 4)eJ0 S� Address ]� Company R . Phone # For Inspector: V .1_ oZ Name & l ate Approved Correction s -e ❑ Test Location Uplift Pull Test (P or F) Test Location Uplift Pull Test (P or F) Test Location Uplift Pull Test (P or F) 1 c. 0 26 YAi . E57 51 7 V+kl-rQ&17 2 27 52 3 28 53 4 29 54 5 30 55 6 31 56 7 32 57 8 33 58 9 34 59 / 10 35 60 11 36 61 12 37 62 13 38 63 14 39 64 15 40 65 16 41 66 17 42 67 18 43 68 19 44 69 20 45 70 21 46 71 22 47 72 23 48 73 24 49 74 25 l 50 75 THIS REP ITT Du Quesne & Associates, Inc. Consulting Engineers Testing Laboratory ON -SITE CONCENTRATED UPLIFT LOAD TESTING OF ROOF TILE IN ACCORDANCE WITH METRO -DADE BUILDING CODE COMPLIANCE PROTOCOL PA 106 Owner's Name: °•E —1.) rb T Job Address 4-NE (0 (p.t•-lt Roofing Contractor ' R°'4-T, O Q F 1 t' '1 Type of Tile: 'g- C?' - COAt-A -T Date Installed 3 Zq'R Approximate Roof Height: 17— feet Roof Pitch r ( Z Type of Access to Roof: Scaffolds X Ladder Other Approximate Square Footage of Roof* 2200 ft 2 Required Testing Force: 35 lbs. Testing Equipment: Chatillion DFIS 100 Date Tested' '4 .Z.°19 IN ACCORDANCE WITH THE CRITERIA OF PROTOCOL PA 106, THIS ROOF ASSEMBLY HAS PASSED THE STATIC UPLIFT QUALITY CONTROL TEST. e Du Quesne, P.E. Engineer 24513 Du •uesne & Associates, Inc. E.B. License #0005245 Lab Certification #94- 0318.01 SITE SPECIFIC INFORMATION TEST RESULTS P = PASS, F = FAIL SKETCH OF ROOF IN BACK UTR 15484 Environmental • Civil • Structural Building Inspection Services Permit #* 44 Z 4g Stoo9 :5,f THIS PA 106 TEST HAS BEEN PERFORMED IN FULL ACCORDANCE TO THE REQUIREMENTS OF DADE COUNTY, WITH NO DEVIATIONS. Please Note: This form is not valid unless Company logo appears in color (burgundy) 7815 S.W. 24th Street • Suite 109 • Miami, Florida 33155 • Telephone (305) 264 -1425 • Fax (305) 264 -1426 SKETCH OF ROOF JOB SHEET NO OF CALCULATED BY DATE CHECKED BY SCALE DATE NOTES' • KETCH OF ROOF ,OB N E 60Z�7T , l..l - S Gica 2 i pl _ SHEET NO L OF DAT• I'1i at CALCULATED BY CHECKED BY N` DATE SCALE • � e L� y, II li ra■■■m■w ■Carm■ ■■■■■ ■■■ ■■ � IT I,L i el i 47 / t I � E� ■■ ■ ■ •■ ■alai■■. ■■E■• ■ IIIII1iIIIIIEIIIIi1I1!iIII ■■` EMBRI f MIENI ■■■ IMIN■■M■■■■ ■■IIWEMEr11Er ■`i %■I ■■ ■SSMI ■MMEMM ■ ■■ ■■ IIMCIMuu1■■rM ■■I ■ ■■■\■ ■■L! ■ ■■■■■ ■EHMa■■OMMEMr■■i■■MNIM ■■ ■EMMI bII1III1IIIIIIIiIiiiiiuiIIII ..... e� ■.`an.i■... ••••••••• 11 NOTES' PERMIT APPLICATION FOR MIAMI SHORES VILLAGE Date Z [ /Job Address JE /O ST Tax Folio Legal Description Historically Designated: Yes No Master Permit # G/67; C/ 8 Owner/Lessee / Tenant Owner's Address Contracting Co. _ her-a- eoo (/15 Said / Address 2,� 70 Q (o(' l` ? /'ud Q / r 4 c 7 SS# 3c 7 6 9 `06co State # Cccc 7 6 C13 Municipal # Competency # Ins. Co. vit t72d 44/7' ""' Architect/Engineer Address Bonding Company Address Mortgagor Address Permit Type (circle one): BUILDING ELECTRICAL PLUMBING / WORK DESCRIPTION , TOO />i C c- V cn .a (Ccrt'r� F l'U) �� Square Ft. <--C� U� ? J Estimated Cost (value) / 0 /vL�(J WARNING TO OWNER: YOU MUST RECORD A NOTICE OF COMMENCEMENT AND YOUR FAILURE TO DO SO MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY (IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.) Application is hereby made to obtain a permit to do work and installation as indicated above, and on the attached addendum (if applicable). I certify that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that separate permits are required for ELECTRICAL, PLUMBING, SIGNS, POOLS, ROOFING and MECHANICAL WORK. OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable la ating construction and zoning. Furthermore, I authorize the above -n con ac o • • e - stat e •f : n V 'ondo President Date Si Not: :. to Owae � or �� Pseai ..t " te My C Jain -- 7')1A Y Ni oz. ST ssion OTA PUBLIC FEES: PERMIT My Comm Esp. 7/6/2000 Bonded By Service Ins No. 548480 t I Personalty Known I I Other 1.0. APPROVED: Zoning Building Mechanical Plumbing RADON C.C.F. (Q r 6 a 4 "I z11 ) Rq Not. ` /s to Contracto My ' ommission Expir Phone l3036 73 (i /75-7 JAMES R. DEAL My Comm Exp. 7/6/2000 Bonded By Service Ins No. 548480 11 Psrsonaly I cwn I !Other Signs of ra • Oyler- Builder NOTARY Electrical BOND 3oa TOTAL DUE Date Z— 0 7 `� Date Engineering PERt - TAX FOLIO NO. STA7. FLORIDA: COL' DADE: THE' Cha;.: 1. Le NOTICE OF COMMENCEMENT '')RDED COPY MUST BE POSTED ON THE JOB SITE AT TIME OF FIRST INSPECTION SIGNED hereby gives notice that improvements will be made to certain real property, and in accordance with lorida Statutes, the following information is provided in this Notice of Commencement. •' 7'-" /62r otion of property and street address: 2. De of improvement: ROOFING 3. Ov. me and address: Inter ;ty: OWNER Nam ss of lee simple titleholder: Sqr. Prig S' oscribed bet ,77:1,1 ir' P. Mromr �t1r�i' gL 3i1U. 571 //,E k' 57 K14 c,1-11 FC ME 4. C: name and address: ROBERTS ROOFING AND SUPPLY, INC . 2170 OPALOCKA BLVD. OPALOCKA, FL 33054 5. S. ent bond required by owner from contractor, it any) Nan :ss: N/A Amc $ 6. Le 1e and address: N/A 7. P n the State of Florida designated by Owner upon whom notices or other documents may be served as provided by ` '3(1)(a)7.. Florida Statutes, Nar ss: N/A 8. Ir himself, Owner designates the following person(s) to receive a copy of the Lienor's Notice as provided in Sec '1)(b), Florida Statutes. Nar ss: N/A 9. E diffr s� ' ied) .0 of this Notice of Commencement: (the expiration date is 1 year from the date of recording unless a Not Prir ame My 1 Expires: 9 COUN . A, ei filed i °l this aiii e is is ° true 'HERESY h on �A�ve�s.nv h . • i se ° ^f Y Cnu h � • I vor 4,.; ; rsCl�`C Prepared by: ROBERT ACOSTA Address 2170 OPALOCKA BLVD. OPALOCKA, FL 33054 ■r. Sit til IDz st ROBERTS ROOFING & SUPPLY Contractor's Name: Job Address: INC. ROOF CATEGORY ❑ (Nail -On Tile) (Mortar ❑ ( Metal Roofs \Wood Shingles & Shakes) ❑ (Other) ROOF TYPE ❑ New Roof tl Re- roofing ❑ Recovering ❑ Repair ❑ Maintenance 1K (Low Slope Application) ❑ (Asphalt/Fiberglass Shingles) Flat Roof Area (ft Gal Sloped Roof Area (ft 2 Total (ft 2 n3 Master Permit No. Exposure category (per ASCE 7 -88): C Building Classification category (per ASCE 7 -88 table 1): 4) bin Per Ft. A v Ft. A V I Deck type:1 "x6" T &G WOOD 1 2" Field: ATTACHMENT 14" RING SHANK NAIL Fastener Type: SPACING Perimeter: 6" Corner: 6 DETAIL 1 & 2 ROOF HEIGHT AND SYSTEM DETAILS (Draw details as needed) G,C4CS:4 e e ,Z6 G(4 . C —.Owe. 06D 2Y ROOF PLAN 11 S 123.01.78 9196 Appendix "E" UNIFORM ROOFING PERMIT APPLICATION PROCESS No. Page -1 Appendix "E" UNIFORM ROOFING PERMIT APPLICATION PROCESS No. • Ridge Ventilation? N/A Deck type: MEAN HEIGHT I Z 1 "x6" T &G WOOD zUnderlayment: Insul #30 FELT TYPE II AS lion: T N/A u ROOF SLOPE D E T A 1 L 3 SLOPED SYSTEM DESCRIPTION Fastener type & spacing: Cap Sheet: Drip edge: D 226 1i" RING SHANK NAI HOT MOP #90 ASTM D Roof Covering: 12" FIELD — ' S 6" LAPS SonTc, .re ''or C ky 22x22 EAVE DRIP 312 TYPE III OR IV .26 GA. GALV. ATTACHMENTS REQUIRED 1) Fire Directory Listing Page 2) Dade County Product Control Notice of Acceptance -Cover Sheet a) Specific System Description b) Specific System Limitation c) General Limitations d) Applicable Detail Drawings 3) Municipal Permit Application 4) Other Component Approvals (Pmaxl 3 x a (Aerodynamic Multiplier): 10 (Pm 1 1' &3 x X ( Aerod ynam ic Mu ltiplier ): CS ( (Pm 73 X ( Aerod ynami c Mu °J G TILE CALCULATIONS M 9. S. = M / ?o6 PCA: 75", I O ) = M r2' 3/e C PCA: I ) - Mg:• d/•g. = M PCA: 7S, Page -2 1011./96 FRI 09:02 FA] 305 3726339 METRO.0A0E PRODUCT CONTROL NOTICE Of ACCEPTANCF Santafe Tile Corporation Ladrillera Santafe Bogota, Columbia Your application for Product Approval of: Santafe Tile Corp. .Vail - -On, .Mortal Sel or Adhesive Sel "San ale S" Roofing Tile under Chapter 3 of the Metropolitan Dade County Code governing the use of Alternate Materials and Types of Construction, and completely described in the plans, specifications and calculations as submitted by: The Center for Applied Engineering, Inc. and Testwell Craig {•aboratorles & Consultants has been recommended for acceptance by the Building Code Compliance Department to be used in Dade County, Florida under the specific conditions set forth on pages 2 through 11 and the standard conditions set forth on page 12. The approval shall not be valid after the expiration date sta}ed below. The Building Code Compliance Office reserves the right to secure this product or material at arty titre for a jobsite or manufacturer's plant for quality control testing. If this product or material fails to perform in +e approved manner, the Building Code Compliance Office may revoke, modify or suspend the use of such product or material immediately. The applicant shall re- evaluate this product or material should any amendments to the South Florida Building Code be enacted affecting this product or material. The Building Code Compliance Office reserves the right to revoke this approval, if it is determined by the Building Code Compliance Office that this product or material fails to meet the requirements of the South Florida Building Code. The expense of such testing w ill be incurred by the manufacturer. Acceptance No.: 96- 4318,,02 Revises No. 94- 1017.17 F.xpires: 10/10199 THIS IS THE COVIASHEE' ,S C.00UTIONS .r1 ••. BCC!) PRODUCT CONTROL BUILDING CODE Ct MMITT)E This application for Product Approval has been reviewed by the Metropolitan Dade County Building Code Compliance Department and approved by the Building Code gommittee to be used in Dade County, Florida under the conditions set forth above. Approved: 10/10/96 METROPOLITAN DADE COUNTY, FLORIDA METRO-DADE FLAGLER BUILDING BUILDING CODE COMPLIANCE OFFICE SUITE 1603 METRO DADE FLAGLER BUILDING 140 WEST FLAGLER STREET MIAMI. FLORIDA 33130.1563 (305) 375.290' FAX (305) 3 INTERNET; mdcc0lOsnaaow.r.at Raul Rod r guez Product Control Supervisor PRODUCT CONTROL SECTION (305) 375.2902 FAX (305) 372 -6339 Charles Danger, P.E. Director Building Code Compliance Dept. Metropolitan Dade County . ® 014 ,10•'11'96 FRI 09 :03 FAX 305 3726339 BCCD PRODUCT CONTROL 41016 Appli;atlt: Santafe Tile Corporation Ladrillera Santafe Bogota. Columbia ROOFING SYSTEM APPROVAL Contact: Daniel Bernal General Manager Santafe Tile Corporation 7225 Northwest 25th Street, Suite 0306 Miami, Florida 3312,2 (305) 5939339 Product Control No.: 96. 0318.02 Product Control No.: _6- 0318.02 Approval Date: Qt tober 10.1996 Expiration Date: October 10,1999 Category: Prepared Roofing Suh- Categnry• High Profile Tile Type: Nail- on/Mortar Set /Adhesive Set Sub•Type: Clay SYIttm Descrjption Ladrillera Santafe, located in Bogota, Columbia, manufacturers clay roof tile for nail -on and adhesive set applications. All Ladrillera Santafe tiles are available sn standard unglazed and a glazed color finish. This Product Control Approval is lws to_the 1 adriller,. Santafe "Santafe S" tile pmtile. Refer to appropriate Product control Approvals for other tile prof lea. Ladrillera Santa% tile profiles have matching trim pieces used for rake hip, ridge hip, and valley terminations. These accessories form a part of this Product Control Approval. The Ladrillera Santa£e's "Santafe S" tile profile has been tested in compliance with the South Florida Building Code requirements for clay, nail-on and adhesive set tile applications. The minimum roof slope for Ladrillera Santafes "Santafe S" nail -on tiles shall be 4 ":12 ". The minimum roof slope for Ladrillera Santafe's "Santafe S" adhesive set tiles shall be 2":12" e the "Profile Drawing" section in this approval for the "Santafe S" profile drawing. The "Santafe Si tile profile has been tested for static uplift performance only. Therefore, any consideration for installation shall be done as an 'Uplift Based System'. Data for attachment calculations is noted in Tables 1 and 2 of this approval. Santa Fc Tile Corporation is the sole. approved distributot of Ladrillera Santafe roof tiles. • TRADE NAMES OF PRODUC MANUFACTURED OR LABELED 13Y APPLICANT Test! Product Product Dimensions Sped ftafins Descriptioq Santaff 'S' Clay Roof 1 18" ASTM C 1167 High profile, interlocking. one•p;ece, Tile w . 1 l!4" 'S' shaped, clay roof tile equipped with '/ thick j two nail holes and a single roll. For nail - on. mortar set and adhesive set applications. Trim Pieces 1 = varies w •• varies varying thickness ASTM C 1167 3 Product Control No.: 96 0318.02 Accessory trim, clay roof pieces for use at hips. rakes. ridges and valley terminations. Manufactured for each tile profile. julo 10/11,96 FRI 09:04 1 305 3726339 BCCD iPRODIiCT CONTROL Tin Caps Product 030 Felt 443 Coated Base Sheet Mineral Surface Cap Sheet Mopping Asphalt Flashing Cement Asphalt Primer Roofing Nails TRADE NAMIES OF PRODUCTS MANUFACTURED OTHERS Dintensi ns N/A N/A 1/A N/A N/A N/A min. 12 ga. with ' /," head min. 32 ga. min. 1 o.d. max. 2" o.d. Test Sneciflca[ione ASTM D 226 type I C ASTM D 626 A STM D 249 ASTM D312 . type 111or1V 1 I ASTM D 4586 ASTM D 41 PA 114 Appendix PA 114. Appendix E Product DescrIRtign Manufacturer Saturated organic felt generic to, be used as a nailed anchor sheet. Saturated and coated organic base sheet for singe or double ply underlayment. Mineral surfaced asphalt roll rooting for use as a top ply in a double ply underlayment system. Asphalt for bonding a mineral surface cap to • a mech. attached base sheet in a double ply underlayment system. Cut back, asphalt based, asbestos free, fiber reinforced, trowel grade cement for repair and flashing applications. Cut back, asphalt based coating used to facilitate bonding of dissimilar materials. Annular ring shank, hot dipped, electro or mechanically galv. roofing nails for use in underlayment attachment. Corrosion resistant circular disc for use in underlayment attachment Product Control No.: 96- 0318.02 generic generic generic generic generic generic generic 017 10. 11.913 FRI 09:05 FAC 303 3726939 BCCD P ODCCT CONTROL Z016 - .Product Tile Nails Tile Screws Roof Tile Mortar ( "TiieTiter"' ") Roof Tile Adhesive ( "Poly'pro3D ►14160 ") Hurricane Clip & Fasteners Valley Flashing Drip Edge Dimensions min. 10d x 3" #8 x 21/2" long 0,335" head dia. 0.131" shark dia. 0.175" screw thread diameter N/A N/A Chin Fac_teners min. 8d x 11/4" min. 26 ga. min. 16" width min. 26 ga. min. 2" face flange min. 2" deck flange Test Specifications PA 1141 Appendix PA 114 Appendix E PA 123 See PCA Cdias PA 114 min.'/," width Appendix E min. 0.060" thick ASTM A 525 PA I11 5 Product Control No.: 96- 0318.02 Product Description Corrosion resistant, ring shank nails. Corrosion resistant, coated, coarse thread wood screws. Prepared mortar mix designed for mortar • set roof tile applications. Two component polyurethane adhesive designed for adhesive set roof the applications. Corrosion resistant bronze, aluminum, stainless steel, galvanized steel or plastic attachment clips for supplemental tile attachment. Clips are installed with corrosion resistant roofing nails compatible with the clip. Galvanized steel valley flashing Galvanized steel drip edge Manufacturer generic generic Bermuda Roof Company, Inc. with current PCA Polyfoam Products, Inc. with current PCA generic generic generic i u, 1 1. 0d FRI 09:06 FAA 305 3726339 Vest Apenc' The Center fer Applied Enginecrin;, Inc. The Center for Applied Engilee:il:g, Inc. The Center for Applied Engineering, Inc. Tho Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. Testwell Craig Laboratories & Consultants, Inc. TEST REPORTS Test jtifier 25- 7205 -4B 2S- 7205.4A 94.156 -2 94 -156 -I Project: 07-07-00-91 (307023) Lab nMK -1 Alberto Ramire2 CCD PRODUCT CONTROL 6 Static Uplift Testing PA 102 (Two Screws) Static Uplift Testing PA 101 (Adhesive Set) Static Uplift Testing PA 101 (Mortar Set) Wind Driven Rain PA 100 Product Control No.: 96. 0318.02 Test Name /Report Static Uplift Testing PA 102 (Two Nails) age 04/95 04/95 08/94 0 09/94 Physical Properties 08/96 ASTM C 1167 X 013 10!11.96 FRI 09:.07_ F.“_ 305 97:8939 BCCD PRODUCT CONTROL SYSTEMS (CONTINUED) Deck Type: Wood, Non - insulated Deck Description: New construction 19 / „” or greater plywood or wood plank. SYSTEM D: Mortar Set or Adhesive Set Application Slop e Range: 2 ":12" to 7 ":12" Note: System D is only Acceptable in this slope range. Underiaymeot: Install underlayment system in compliance with Dade County Application Standard PA 120. (See System Limitation #5.) Rooting Tile: Install tile in compliance with Dade County Application Standard PA 120. (See "Data for Attachment Calculations" included in this Approval.) Comments: 1. For re -roof applications, "i plywood is an acceptable substrate. • Product Control No.: 96- 0318.02 q1 LU : 1 .JG r1'.. JO , nVl. - SYSTEM LIMITATIONS 9 Frank Zu!oaga Product Control No.: 96-0318.02 1. The standard minimum roof pitch for Ladrillera Santafes's "Santafe S" high profile tile shall comply with Dade County Application Standards PA 118, PA 119 or PA 120, depending on the method of installation. 2. For nail -on applications, fasteners for mechanical attachment of tiles shall have a head diameter larger than that of the preformed holes in they tile. 3, System installation shall be in compliance with the system specifications outlined in this Product Control Approval. The method of attachment utilized shall provide a minimum characteristic resistance load greater than or equal to the required uplift resistance determined in compliance with Dade County Protocol PA 115 or PA 127. The Ladrillera Santafe "Santafe S': tile profile has been tested for static uplift performance only, therefore, attachment calculations for installation in compliance with PA 115 or PA 127 shall be done a>. an 'Uplift Rased System' t. For mortar or adhesive set tile applications, a field static uplift test by a Dade County accredited testing agency, in compliance with Dade County Protocol PA 106, shall be performed. 5. For mortar set tile applications, 30/90 hot mopped underlayment applications may be installed perpendicular to the roof pitch unless stated otherwise by the underlayment material manufacturer's published literature. 6. All tiles shall bear the imprint or identifiable narking of the manufacturers name or logo for identification in the field. 7. Applications for roofing permits shall include a completed Section 11 of the Uniform Building Permit, a copy of Ladrillera Santafe's current specifications and details, a copy of this Product Control Approval and a copy of the Product Control Approval of any Roofing Component used in the proposed the application. Reference shall bi made to appropriate data for the required fire rating. 8. The applicant shall retain the services .of a Dade County certified testing laboratory to maintain quality control in compliance with the South,Florida Building Code and related protocols. 9. Any amendments to these provisions shall be in co mpliance with Sections 203 and 204 of the South Florida Building Code. 10•'11/96 FRI 09:09 FAX 305 3726339 Tile Profile Santafe S Clay [Roof Tile Table 2: Tile Profile L Sentafe S Clay Roof Tile ' Minimum 3" headlap. BCCD PROUCCT COYTKUL Product Control No.: 46. 0318.02 DATA FOR ATTACHMENT CALCULATIONS Table 1: Average Weight (W) and Dimensions (1 x w) Weight - W (lbf) Length - I (feet) Width - w (feet) 6.60 1 1.50 7 0. °6 Min mum Characteristic Resistance Load - F' (lbf) Tile Minimum CharacteristiC Application Resistance Load (lbf) 31.00 26.50 Nail -On SyStem Two Approved Nails' Nall -On Syitem One Approved Screw Mortar Set Adhesive Set T he two nail holes shall be located at 2.5118" and 2" from the head and 2 -518" and 2- 5116" from the interlock edge. respectively. i 2 The screw hole shall be located at 2 -5/16" from the'head and 2- 5116" from the interlock edge. 33.60 85.10 P.06 V - V PROFILE DRAWING i LADRILLERA SANTAFE ''SAITAFE S" CLAY ROOF TILE 11 Product Control No.: 96.0318.02 Santafc Tile Corporation Ladrillera Santafe • Bogota, Coiumbia Product Control No.: 96- 0318.02 ACCEPTANCE NO.: 96-0314.02 APPROVED 1allber 10. 1996 EXPIRES : October 10. 1999 NOTICE OF .CCEPTANCI STANDARQJ`.OND1TIONS 1. Renewal of this Acceptance (approval) shall be considered after a renewal application has been filed and the original submitted documentation, including test supporting data, engineering documents, are no older than eight (8) years. 2. Any and all approved products shall be per:r.anegtly labeled with the manufacturer's name, city, state, and the following statement: "Dade County Product Control Approved ", or as specifically stated in the specific conditions of this Acceptance. 3. Renewals of Acceptance will not be considered it a) There has been a change in the South Florida Building Code affecting the evaluation of this product and the product is not in compliance with the code changes; b) The product is no longer the same product (identical) as the one originally approved; c) if the Acceptance holder has not complied with all the requirements of this acceptance, including the correct installation of thi: product; d) The engineer who originally prepared, signed and sealed the required documentation initially submitted , is no longer practicing Ole engineering profession. 4. Any revision or change in the materials, use, and/or manufacture of the product or process shall automatically be cause for termination of this Acceptance, unless prior written approval has been requested (through the filing of a revision application with appropriate fee) and granted by this office. 5.. Any of the following shall also be grounds for removal of this Acceptance: a) Unsatisfactory performance of this product or process; b) Misuse of this Acceptance as an endodsement of any product. for sales, advertising or any other purposes. Acceptance number preceded by the words Dade Counry, Florida, and followed by the may be displayed in advertising literature. If any portion of the Notice of Acceptance is it shall be done in its entirety. Acceptance as well as approved drawings and other documents, where it applies, shall be user by the manufacturer or its distributors and shall be available for inspection at the job The copies need not be resealed by the engineer. 8. Failure to comply with any sectiot► of this Acceptance shall be cause for termination and removal of Acceptance. 6. The Notice of expiration date displayed. then 7. A copy of this provided to the site at all times. 9. This Acceptance contains pages I through 12. END OF THIS ACCEPTANCE utosga Plans Exarniner. Product Cor roI Div. . t f - ; 19 -98 03:14P Polyfoam P•ODUCTC•NTR•LNOTIC Polyfoam Products, Inc. 2400 Spring - Stuebner Road Spring, TX, 77383 Your application for Product Approval of: an i‘p 954 475 1.46 Products Inc. OF CCEPT 954 475 -1462 P.02 METROPOLITAN DADE COUNTY, FLORIDA METRO -DADE FLAGLER BUILDING BUILDING CODE COMPLIANCE OFFICE METRO•DADE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 MIAMI, FLORIDA 33130.1553 (305) 375.2901 FAX (305) 315.2908 PRODUCT CONTROL DIVISION (305) 375-2902 FAX (305) 372 - 6339 l ro c , • I I ,of•'ile Ih .ive under Chapter 8 of the Miami -Dade County Code governing the use of Alternate Materials and Types of Construction, and completely described in the plans, specifications and calculations as submitted by: Tho Confer for Applied Engineering, Inc. and Miles Laboratories) Polymers Divieina has been recommended for acceptance by the Building Code Compliance Office to be used in Dade County, Florida under the specific conditions sct forth on pages 2.14 and the standard conditions on page IS. This approval shalt not be valid ellcr the expiration date stated below. The Building Code Compliance Office reserves the right to secure this product or material at any time from a jobsitc or manufacturer's plant for quality control testing. if this product or material falls to perform in the approved manner, the building Code Compliance Office may revoke, modify, or suspend the use of such product or material immediately. The Building Code Compliance Ot7ice reserves the right to revoke this approval, if it is determined by the Building Code Compliance Office that this product or material fails to meet the requirements of the South Florida Building Code. The expense of such testing will be incurred by the manufacturer. ACCEPTANCE NO.: 98- 0303.02 Renews: 9G-Q402 92 EXPIRES: 04 /16 /01 T. IS ' T . OV ' SHEET SEE ADDITIONAL, P G ' ' E s RS C IC ND CF.NF.R 1 CONDITIONS BVILPING, COQE COMMITTEE . This application for Product Approval has been reviewed by the Miami - Dade County Building Code Compliance Office and approved by the Building Code Committee to be used in Dade County, Florida under the conditions set forth above. APPROVED: 0406/93, 1 ul Rodriguez Product Control Supervisor Charles Danger, P.E. Director Building Code Compliance Dept. Miami.Dado County . .•- • ...- .- .. ...I ,.n.....wd...ni iww.aAtn • InLBrrls m •• • • 05/19.98 TUE 14:27 FAX 305 863 9692 - May -19 -98 03:14P Pc,lyfoam Products Inc_ POLYFOAM PRODUCTS, INC. Aoplicant: Polyfosm Products, Inc. 2400 Spring - Stuebner Road Spring, Texas 77383 -1132 Catetiory; Sub-Category: IY112; Sub -Tyge: PRODUCT CONTROL NOTICE OF ACCEPTANCE ROOFING COMPONENT APPROVAL Roofing Component Fastening/Adhesive Roof Tile Adhesive Two Component Polyurethane Polyfoam Products, Inc., produces two - component expanding polyurethane adhesive for tho attachment of clay and concrete roof tile. Pulypro® Al!160 is specially designed for application of concrete and clay roof tile over a variety of roof deck substrates and underlayment materials. Polypro® adhesive is applied with proprietary Foampro® RTF1000 dispensing equipment. Approval of this product is specific to the two component mix and Foampro?tl RTC 1000 dispensing equipment. Alternative methods of dispensing will require a revision to this approval. Polypro® adhesive shall be applied only by 'Qualified Applicators', licensed by Polyfoam Products, Inc. Certificates and identification cards are issued to applicators upon successful completion of a application training program. Approval of this adhesive system is contingent upon application by a 'Qualified Applicator. Contact: EAST COAST SUPPLY 7p•. .4r 1.40G System Description Pat Murray P.O. Box 1132 Spring, Texas 77383 -1132 Phone: (713)350.8888 Fax: (713)2R8.6450 954 475 -1462 Product Control No.: 98- 0303.02 Product Control No,: 2=- 0303.02, Approval Date: ARM 16, 129/1 Expiration Date: Anrll 1 a 6. ZDD1 81003 P.03 May-19-913 03:14P ry 'y' �a��• POI,YFOAM PRODUCTS, INC. Product Control No.: 28.0303.02 TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT Test Product Product Dimensions Snecificationa Descrig en Polypro® AHI60 N/A PA 101 Two component polyurethane Foampro® RTF 1000 N/A See Detail Attached Dispensing Equipment Page 3 of 15 Frank Zuloaga, RRC Roofing Product Control Examiner U5 ;19-98 11E 1T 9 FAX 305 863 9692 EAST COAST SUPPLY 954 4 ?5 1462 . May -19 -98 03:14P Polyfoam Products Inc. POLYFOAM PRODUCTS, INC. Product Control No.: 98- 0303.02 TRADE NAMES OF PRODUCTS MANUFACTURED HY OTHERS Product Test Criteria Product Description Manufacturer Underlayment Roof Tile PA 120 All Dade County Component Approved MI Dade products as detailed in Dade County County Application Standard PA 120 Approved Products PA 101 All Approved roof the systems having All Dade tested in compliance with Dade County County Protocol PA 101, as detailed in the systems Approved section of this Component Approval Products Page 4 of 15 954 475 -1462 P•O r.... 7..1...... DDC Zoos 954 475 1452 May -19 -96 03:14P Polyfoam Products Inc. POLYFOAM PRODUCTS, INC. Product Control No.; 98- 0303.02 TEST REPORTS t Ageticy Test Identifier Test Namc/Rcnor4 ate Center for Applied Engineering Center for Applied Engineering Center for Applied Engineering Center for Applied Engineering Center for Applied Engineering Center for Applied Engineering Miles Laboratories Polymers Division Ramtech Laboratories, Inc. Southwest Research Institute Southwest Research Institute Trinity Engineering #94.060 Miami Dade Protocol 04/08/94 PA 101 257818-IPA Miami Dacia Protocol 12/16/96 PA 101 25.7438.3 SSTD 11.93 10/25/95 25-7438-4 SSTD 11.93 10/25/95 25- 7438 -7 SSTD 11 - 11/02/05 25 -7492 SSTs) 11 -93 12/12/95 NB- 589 -631 ASTM D 1623 02/01/94 9637 -92 ASTM E 108 04/30/93 01.6743 -011 ASTM E 108 0!- 6739.062b[1) ASTM E 84 7050.02.96 -1 PA 114 Page 5 of 15 954 475 -1462 P.06 Frank Zuloaga, RRC 11/16/94 01/16/95 03/14/96 u ..,.r;nn 0.....1..01 P'nnt, I Nsam1t er 05/19.'98 TUE 14:30 FAX 305 363 9692 • .May -19 -96 03:16P Palyfoam Products Inc. POLYIIrOAM PRODUCTS, INC. Property Density Compressive Strength Tensile Strength Water Absorption Moisture Vapor Transmission Dimensional Stability Closed Cell Content EAST COAST SUPPLY 954 47= ice2 TYPICAL PHYSICAL PROPERTIES Ltrd ASTM D 1622 ASTM D 1621 ASTM D 1623 ASTM D 2 127 ASTM E 96 ASTM D 2126 ASTM D 2856 Page 6 of 15 1.6 lbs. /ft.' 954 476-1462 Results 18 PSI Parallel to rise 12 PSI Perpendicular to rise 28 PSI Parallel to rise 0.08 I.bs. /Ft 3.1 feral / Inch 86% Product Control No.: -030 r +0.07% Volume Change ® -40 F., 2 weeks +6.0% Volume Change @158 100% Humidity, 2 weeks Note: The physical properties listed above are presented as typical average values us determined by accepted ASTM test methods and are Aubjvet to normal manufacturing variation. P.07 VA 007 05 19.98 TUE 14:30 FAX 305 863 9692 EAST COAST SUPPLY 1j P.08 May -19 -98 03:15P Polyfoam Products Inc. 964 476 - 1462 POLYFOAM PRODUCTS, INC. Product Control No.: 98-0303.02 SYSTEMS Deck Type: Wood, Non - insulated, New Construction/Reroof Deck Description: 15 /32" or greater, plywood or wood plank. SYSTEM A: 'Adhesive Set Application Slope Range: 2 ":12" to 7 ":12" Undcrlaymcnt: Shall comply with Miami -Dade Roofing Application Standard PA 120 Roofing Tile: Any roof tile assembly having a current shall be applied in compliance with the Component Application section and the corresponding Placement Details of this Notice of Acceptance. The adhesive attachment shall provide sufficient attachment resistance expressed as a moment to meet or exceed the required moment of resistance determined in compliance with Miami -Dade County Roofing Application Standards PA 115 or PA 127. The adhesive attachment data is noted in the roof tile assembly NOA. Comments: I. All 'System Limitations' noted in the tile Roof System Assembly Product Control Approval shall apply. Page 7 of 15 Table 1: Adhesive Placement t or Estcb Generic Tile Profilo Tile Profile Placement Detail Two-Piece Barrel N1 'S' Shaped #2 Double Roll y3 Flat 4 May -19 - 98 03:1SP Polvfoam Products loc. POLYFOAM PRODUCTS, INC. Product Control No.: 98.0303.02 COMPONENT APPLICATION I. Polypro® A1.1160 tile adhesive shall only be applied over an underlayment installed in compliance with application instructions detailed in its NOA,. Underlaymcnt may be any underlaymcnts or underlayment systems listed Miami -Dade County Roofing Application Standard PA 120. �) 2. Adhesive application shall be in accordance with the instructions provided herein. Trite manufacturer may provide additional instructions subsequent to this approval date which may prevail. Installation must be by a Factory Trained 'Qualified Applicator' approved and licensed by Polyfoam Products, Inc. 964 416 -146c P.10 3. Calibration of the Foampro(IP dispensing equipment is required bofore application of any adhesive. The mix ratio between the "A" component and the "B" component shall be maintained between 1.0- 1.15 (A) : 1.0 (8). The dispense timer shall be set to deliver 0.08 to 0.15 pounds per tile as determined at calibration. No other settings shell he approved without revision otNOA. 4. Adhesive shall be dispensed in a 17 In' to 23 in' pad at time of application, The cured pad shall be approximately 5" x 12 ". Foam placement shall be in accordance with the 'Placement Details' herein. Each generic tile profile requires a specific placement, as noted in Table 1, below 5. Adhere tile directly in freshly applied adhesive. Tile must be set within 2 to 3 minutes after foam has been dispensed. Page 9 of 15 Frank Zuloaga, RRC May 03:16P Polyfoam Products Inc. 9t 4 476 -1462 P.11 POLYFOAM PRODUCTS, INC. Product Control No.: 98- 0303.Q2 SYSTEM LIMITATIONS 2. Polypro® AI-1160 adhesive shall be installed only by 'Qualified Applicators' approved and licensed by Polyfoam Products, Inc. • 3. For adhesive set tile applications, a field static uplift test by a Miami -Dade County accredited testing agency, in compliance with Mianti•Dadc County Roofing Application Standard PA 106. shall be required not less than 72 hours after application to confirm tile adhesion. 4. Refer to application drawings published by the National Tile Manufacturers Association for penetrations and terminations, as well as the 'Placement Details' included with NOA. 5. Refer to tile Roof Tile Assembly Product Control NOA for system acceptance with this Component. 6. Refer to the Prepared Roof Tile Assembly for (ire rating. 7. Polypro® AH 160 shall not be exposed permanently to sunlight. 8. Polypro® AH160 shall be applied with Fonmpro RTFI000 dispensing equipment only. 9, Polyfoam Products Inc. shall supply Building Official with a list of 'Qualified Applicators' approved and licensed by Polyfoam Products, Inc. Page 10 of 15 Frank Zuloaea, RRC 0/19/98 1E:37 EAST COAST SUPPLY 4 954 475 1462 May-19-98 03:16p Polyfoam Products Inc 954 475 POLITOAM PRODUCTS, INC. PLACEMENT DETAILS 22 Tom osmoos 42poldlib getout. rho.= Adhesive 12 t. 4' from !lig eue.,14. edgy at mood tlia. Moo lootibli Mo. i)Pl000 snoop adtrobro to odder* 17 is 23 sq.. lushes in goottnat 4.4444 the ;■..; 4741. Iltoommdd lop portion of the ••va daaarae tilL Abed bo •• osoul owe. of pa% Uldo. Emmy* savo amid •41 par Mild *WM, 114.111 ore Swab ad sow Wm, ram* Weary* (anortwe show NS S44/1111r e 0.114m4s1 Zioto ler Stoop OW 440$4041444a. I I pi' o p o p>, .4 I I It It w•evboi• lissola Omani 11.11 tholaigh pi•stio odes•nt ("Owl rmatrof bp gods) Placement Detail 01: Two-Piece Barrel Profile NO.185 P001 Product Control No.: 98-0303.07 Optlow.1 Pak44.414, Itorter do 4 .4.1461towilmol **Pod of P.12 .05/19/98 16:38 EAST COAST SUPPLY -0 954 475 1462 May -19 -98 03:16P Polyfoam Products Inc. POIXFOAM PRODUCTS, INC. ndt tb..y fb pIa t . e,.wd Qwb.s required by c u.r+.t.r...ot PLACEMENT DETAILS (CONTINUED) Placement Detail #2: 'S' Shaped Tile Profile Den.. I'1 ..• t f 954 475 -1462 Avs4, swoosh .M..lv. to ..AMo. 17 to 23 swim. boohoo be auw{M1 oda tb. Ula W. Olosolop NO.185 P002 Product Control No.: 98 -030' P..ds boond iloioedeo P -13 dig 4 47314E52 May 03:16P Poly-foam Products Inc. POLYFOAM PRODUCTS, INC. Mail Mama* eimaaal (*Ira code) PLACEMENT DETAILS (CONTINUED) Placement Detail #41: Plat Profile Page 14 of 15 954 475-1462 P . Product Control No.: 98-0Z93.02 May -19 -98 03:16P Polyfoam Products Inc. POLYFOAM PRODUCTS, INC. Product Control Nod, 98- 0303,02 1 • 00 . 1 0 1 . G•s000t (whoa millivolt Ip .odo) PLACEMENT DETAILS (CONTINUED) 1.■.411 Ew. tors. X14. ee..s. only, hoop • 414 • 111 w• dw /vohootl.7 4' r► from opoopholoo. Placement Detail #3: Double Roll Profit Page 13 of 15 954 475 -1462 P.14 hover swoosh ~dhow.o t. aching,. 17.23 . Nhdh.. l■ ..~toot whtth OW WO. row. Clw.ro Frank Zuloaga, RRC ROOfn¢ Product Contrnl FY Snhinor r.r r v r, 1 Q ay -1 9 -98 03:17P Polyfoam Products Inc. 954 475 -146 POLYFOAM PRODUCTS, INC. Polytonal Products, Inc. 2400 Spring- Stuebaer Road Spring, TX 77383 9 This Acceptance contains pages t through IS. END OF It ll$ ACCEPTANCE Page 15 of 15 Product Control No.: 9 ACCEPTANCE NO: 9 . 303 APPROVED :Apt l�_ 6am EXPIRES : Ant [ tool (y1' F , OF AC PT _ r• `TA )Alt CON t i . S 1 Renewal of this Acceptance (approval) shall be considered after a renewal application has been filed a nd the original submitted documentation, including test supporting data, engineering documents, are no older than 2 Any and all approved products shall be permanently labeled with the manufacturer's name, city, state and following statement: "Miami - Dade County Product Control Approved ", or as specifically staled in the the . specific conditions of this Acceptance. 3 Renewals of Acceptance will not be considered it': a) There has been a change in the South Florida Building Code affecting the evaluation of thin rodu the product is not In compliance with the code changes; b) The product is no longer the same product (identical) as the one originally approved; P ct and c) if the Acceptance holder has not complied with all the requirements of this acceptance, including correct installation of the product, tng the d) The engineer who originally prepared, signed and sealed the required documentation initially submitted, is no longer practicing the engineering profession. ed, 4 Any revision or change in the materials, use, and/or manufacture of the product or process shall automatically be cause for term (through of this Acceptance, unless prior written approval has been requested throw gh the filing of a revision application with appropriate fee) and granted by this office. 5 Any of the following shall also be grounds for removal of this Acceptance_ a) Unsatisfactory performance of this product or process; b) Misuse of this Acceptance as an endorsement of any product, for sat purpou's' es, advertising or any other 6 The Notice of Acceptance number preceded by the words Miami• expiration date may be displayed in advertising literature. I f an Dati Coe, Florida, o and followed he displayed then it shall be done in its entirety. Y portion n of f the Notice of Acceptance nce is s 7 A copy of this Acceptance as well as approved drawings and other documents, where it applies, provided to the user by the manufacturer or its distributors and shall be available for inspection at shall at he job site be at all times. The copies need not be resealed by the engineer, h 8 Failure to comply with any section of this Acceptance shall be cause for termination and removal of Acceptance. • 4 • • COVERING MATERIALS (TEVT) SYSTEMS (TGFU) — Continued . l): One or more Layers perlite, wood fiber, glass .rethane, perlite / isocyanurate composite, perlite/ wood fiber /isocyanurate composite, phenolic. nom layers of Type G2.or G3. . ): One or more layers of Type G1. ore layers of "Ruberoid Torch "' (smooth or. granule), (granule), "Ruberoid Mop" (smooth or granule) or :granule). . 97, 1-1/2 ='3 gat/sq or •gravel. Incline: 1/2 more layers perlite, glass fiber, 3/4 in. min, perlite / isocyanurate composite, perlite /urethane 1 -1/2 in. min. • 1): One or more layers of Type. G1, G2 or G3. )re layers of "Ruberoid Torch" (smooth or granule), (granule), 'Ruberoid Mop" (smooth or •ranule) er granule). iminum Roof Coating" at 1 -2 gal/sq. . Incline: 1/2 • I: One or more layers perlite, glass fiber, 3/4 in. ethane, perlite /isocyanurate composite, perlite/ henolic, 1 -1/2 in. min. .. ore layers of Type G2 "GAFGLAS #75 Base Sheet", nicely fastened in place. e layers of Type 61 "GAFGLAS Ply 4 ", .hot mopped Mop FR" (granule. GAF Fibered Aluminum Coating at 1-1/2 gal/sq'or lsion at 3 gat/sq. . • Incline: 1/2 : One or more layers perlite, glass fiber, .3/4 in. ethane, perlite / isocyanurate composite, perlite/ henolic, 1 -1/2 in. min. ore layers of Type G2 "GAFGLAS #75 Base Sheer, iicalty fastened in place. layers of Type G1 "GAFGLAS Ply 4 ",.or "GAFGLAS )lace. Torch FR" (granule). ;AF Fibered Aluminum Coating at 1 -1 /2 gal,/sq or Sion at 3 gal /sq. Incline: 1/2 te, 2 in. min., wood fiber, perlite or gloss fiber, pped or mechanically fastened in..place.. Joints )re layers of Type G2 `GAFGLAS 175, Base Sheer, ically fastened in place. One or more layers of Type 61 "GAFGLAS,Ply 4" or place. orch FR" (granule). •. AF Fibered Aluminum Coating at.1 -1/2 gal/sq or sion .at 3 gat/sq. Incline: 1/2 Lsocyanurate, perlite or glass fiber,any thickness, ically fastened in place. Joints offset.6 in. . re layers of Type G2 "GAFGLAS 875 Base Sheer, ically fastened in place. layers of Type 61 "GAFGLAS Ply 4" or "Ply 6 ", hot orch FR" (granule). 4F Fibered Aluminum Coating at 1 -1/2 gat/sq or .ion at 3 gat/sq. Incline: 1/2 Isocyanurate, wood fiber board, perlite, glass )t mopped or mechanically fastened :in place. e layers of Type G2 "GAFGLAS #75 Sheer, ne or more layers of Type G1 "GAFGLAS Ply 4" or ROOF COVERING MATERIALS (TEVT) 13 7 ROOFING SYSTEMS (TGFU)— Continued GAF Fibered Aluminum Coating at.1-1/2 gal/sq. 15. Decks C -15/32 ► Inclines 1/2' •• Insulation- (Optional: Perlite,•fiber glass; isocyanurate, urethane, perlite/ - . isocyanurate composite or••phenolic.• . • •• • Base Sheet: Ontor more layers Type.42.or G3 base.sheet, hot mopped or mechanically fastened. • • • P Sheet (Optional): One or more layers Type 6.1, hot mopped in place. M " Ruberoid Mop FR'l<or "Ruberoid Mop 170 FR" (granule). • 16. Deck: C -15/32 • • Incline: 1/2, Insulation (Optional): Perlite, fiber glass, isocyanurate, urethane, pertite/ isocyanurate composite or phenolic, offset 6 in. from joints. • Base Sheet: One or more layers of Type G -2 or G -3. base sheet, hot mopped or mechanically, fastened. ...Ply Sheet tional : One or :more •: y . . ( QP ) . ' ( ayers of Type G -1, hot mopped in place. • Membrane: 'One layer of "Ruberoid Torch" or 7 Ruberoid Mop" (smooth). Membranes One layer of "Ruberoid Torch 'FR"' or Ruberoid Mop FR" (granule) 17. Decks NC • Incline: 1 Insulation (Optional): Perlite, fiber glass, wood fiber, isocyanurate, urethane, perlite / isocyanurate composite or phenolic. Base Sheet: One or more layers Type G2 or G3 base sheet; hot mopped or mechanically fastened. . Ply Sheet (Optional): Orie or mare la Type 61,' hot mopped in place. ..Membrane: One layer of "Ruberoid Mop FR or "Ruberoid Mop 170 FR" • (granule). . 18. Dods NC Inclin 1/2 Insulation (Optional): Perlite, fiber glass, wood fiber, isocyanurate, urethane, perlite / isocyanurate composite or phenolic. , Base Sheet (Optional): One or more layers of Type G - or G - base sheet, hot mopped or mechanically fastened. Pty Sheet.(Optional): One or more layers of Type G -1, hot mopped in place. Membrane: One layer of "Ruberoid Torch" (smooth), "Ruberoid Mop" (smooth). Membrane: One layer of "Ruberoid Torch FR" (granule). 19. Deck: NC Incline: 1/2 Insulation (Optional): One or more layers of perlite, glass fiber, isocyanurate, urethane, perlite /isocyanurate composite or phenolic, any thickness. Base Sheet:. One or mor plies 61 or G2, hot mopped or adhered with • .Karnak Chemical Co. "No:.81" or Gibson - Homan "No..6160" cold applied adhesive at 1-1/2 gal/sq. Membrane: One layer of "Ruberoid Mop FR" or "Ruberoid Mop 170 FR" granule), hot mopped or adhered with Karnak Chemical Co. "No. 81" or Gibson-Homan "No. 6160" cold applied adhesive at ,1 -1/2 gal/sq. 20. Decks C - 15/32 Incline: 1/4 Insulation: Polyisocyanurate, any thickness. Base Sheet: "GAFGLAS 175" (Type G2), mechanically attached. Membrane: One or more plies of "Rubberoid Torch smooth). Membrane: "Ruberoid Torch FR" (granule). 21 Dedu C -15/32 . Incline: 1/2 ..Insulation (Optional): Polyisocyanurate, wood fiber, perlite, glass fiber • any thickness, hot mopped or mechanically fastened. Base Sheet: One or more plies of Type G2 "GAFGLAS #75" oe "Ruberoid 20 FR" base sheets, hot mopped or mechanically fastened. • Membrane: One or more plies of "Ruberoid 30 FR" hot mopped in place. Deck: C-15/32 Incline: 1 Insulation (Optional): Polyisocyanurate, wood fiber, perlite, or glass fiber any thickness, hot mopped or 'mechanically fastened. Base Sheet: One or more pies of Type G2 "GAFGLAS 075" hot mopped or mechanically fastened. Ply Sheet: One or more plies of "Ruberoid 20" or "Ruberoid 20 FR ", hot mopped in place. Membrane: One or more plies of "Ruberoid 30 FR ",.hot mopped in place. Class B -Fully Adhered • • eds: C -15/32 Incline: 1/2 Insulation (Optional): One or more •layers perlite, wood• fiber, glass • 22. 1. D PRODUCT CONTROL NOTICE OF ACCEPTANCE GAF Materials Corporation 1361 Alps Road Wayne, NJ 07470 Your application for Product Approval of: GAF Ruberoid® Modifed Bitumen Roof Systems for Wood Decks under Chapter 8 of the Metropolitan Dade County Code governing the use of Alternate Materials and Types of Construction, and completely described in the plans, specifications and calculations as submitted by: Dyrratech Engineering, Inc., Factory Mutual Research Corporation, and Underwriters Laboratories, Inc. has been recommended for acceptance by the Building Code Compliance Office to be used in Dade County, Florida under the specific conditions set forth on pages 2 -60 and the standard conditions on page 61. This approval shall not be valid after the expiration date stated below. The Building Code Compliance Office reserves the right to secure this product or material at any time from a jobsite or manufacturer's plant for quality control testing. If this product or material fails to perform in the approved manner, the Building Code Compliance Office may revoke, modify, or suspend the use of such product or material immediately. The Building Code Compliance Office reserves the right to revoke this approval, if it is determined by the Building Code Compliance Office that this product or material fails to meet the requirements of the Building Code Compliance Office that this product or material fails to meet the requirements of the South Florida Building Code. The expense of such testing will be incurred by the manufacturer. Acceptance No.: 97- 0804.14 Expires: 11/06/00 THIS IS THE COVERSHEET, SEE ADDITIONAL PAGES FOR SPECIFIC AND GENERAL CONDITIONS BUILDING CODE COMMITTEE This application for Product Approval has been reviewed by the Metropolitan Dade County Building Code Compliance Office and approved by the Building Code Committee to be use9�, n Dade County, FI S idi under the conditions set forth above. /. 4 / -, r( Approved: 11/06/97 Revises No.: 95- 1003.03 i i', G � f Raul Rodriguez Product Control Supervisor Charles Danger, P.E. Director Building Code Compliance Dept. Metropolitan Dade County PRODUCT CONTROL NOTICE OF ACCEPTANCE ROOFING SYSTEM APPROVAL Applicant: GAF Materials Corporation 1361 Alps Road Wayne, NJ 07470 Category: Membrane Roofing System Sub - Category: Built -up Roofing Type: Modified Bitumen Sub -Type: APP and SBS System Description GAF Materials Corporation has been manufacturing commercial roofing products for more than 100 years. GAF produces a wide range of roof products for built -up roofing systems. The modified bitumen products include both APP and SBS products in smooth, granule and fire rated versions. In addition, GAF offers two ply modified systems to meet the specification requirements for multilayer SBS modified specifications. GAF products are distributed through a wide network of roofing wholesale distributors throughout the South Florida area. GAF provides warranted systems over various insulated and non - insulated substrates, copies of which can be obtained from GAF and can be found in the Ruberoid Modified Bitumen Application and Specification manual published annually. GAF roof system assemblies have been extensively tested at Factory Mutual Research Corporation and Underwriters Laboratories. GAF modified bitumen membranes have been tested in compliance with ASTM D 5147 test requirements. Contact: William J. Woodring Director of Technical Services (973) 628- 4134 Page 2 of 61 Product Control No.: 97- 0804.14 Approval Date: November 6, 1997 Expiration Date: November 6, 2000 Frank Zuloaga, Roofing Product Control Examiner Insulation Types: Material Wood Material Wood Basalt Wool Perlite Polyisocyanurate Composite Board Wood Fiberboard High Density Wood Fiberboard Rockwool Maximum_Desien Pressure Design Pressure -75psf Maximum Fire Classification Classification - 'A' Note: Fire classifications and maximum design pressures do not reference all assemblies over all deck types. Review system listings for design pressures and the Underwriters Laboratories Roofing Materials Directory for Fire Classifications. Page 3 of 61 Frank Zuloaga, Roofing Product Control Examiner Product GAF Asphalt Concrete Primer GAF Mineral Shield® Granules GAF WeatherCoat® Emulsion GAF Premium Fibered Aluminum Roof Coating GAF Jetblak All Weather Plastic Cement GAFGLAS 475® GAFGLAS #80 UltimaTM Base Sheet GAFGLAS Ply 6® GAFGLAS Flex Ply 6 GAFGLAS Ply 4® GAFGLAS® Mineral Surfaced Cap Sheet TRADE NA.IES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT Test Dimensions Specification 5, 55 gallons ASTM D 41 60 Ib. bags ASTM D 1863 5 gallons I, 5 gallons ASTM D 2824 Fibered aluminum coating. 1, 5 gallons 3 sq. roll 75 Ib. roll ASTM D460I ASTM D 2178 ASTM D 2178 5 sq. roll ASTM D 2178 76 Ib. roll ASTM D 3909 2 Sq. Roll 70 lbs. /roll 5 sq. roll 45 Ib. roll 5 sq. roll 45 lb. roll e ASTM 1227 ASTM D 3019 ASTM D 3409 Page 4 of 61 Product Description Asphalt concrete primer used to promote adhesion of asphalt in built -up roofing. Granules for surfacing of exposed asphalt, cold process cement or emulsion. GAF Mineral Shield Granules shall be used for flashing applications only. Surface coating for smooth surfaced roofs. Refined asphalt blended with a mineral stabilizer and fibers. Permits adhesion to wet and dry surfaces. ASTM D 4601 Asphalt impregnated and coated glass mat base sheet. Asphalt impregnated and coated, fiberglass base sheet Type VI asphalt impregnated glass felt with asphalt coating. Type VI asphalt impregnated glass felt with asphalt coating. Type IV asphalt impregnated glass felt with asphalt coating. Asphalt coated, glass fiber mat cap sheet surfaced with mineral granules. ran Zuloaga, Roofing Product Control Examiner Product GAFTITE® Base Sheet Fastener and Plate Galvalume Plates NTB Fasteners Polypropylene Plates Ruberoid® 20 Ruberoid® Mop Granule RUBEROID MOP Smooth RUBEROID MOP PLUS RUBEROID MOP 170FR RUBEROW MOP FR RUBEROID TORCH Smooth RUBEROID TORCH Granule Test Dimensions Specification 3" and 3 ' /," 3" and 3 ' /." 1.5 sq. roll 1 sq. roll 103 lbs. 1 sq. roll 87 lbs. 1 sq. roll 102 lbs. 1 sq. roll 103 lbs. I sq. roll 105 lbs. 1 sq. roll 87 lbs. 1 sq. roll 102 lbs. PA 114 ASTM D 5147 ASTM D 5147 ASTM D 5147 ASTM D 5147 ASTM D 5147 ASTM D 5147 Page 7 of 61 Product Description Base sheet fastening assembly. PA 114 Round galvalume stress plates. PA 114 Fastener for use in gypsum, tectum and lightweight insulating concrete decks. PA 114 Round polypropylene stress plates. SBS modified asphalt base sheet and interply sheet reinforce with a glass fiber mat. AST`1 D 5147 Non-woven polyester mat coated with polymer modified asphalt and surfaced — with mineral granules. ASTM D 5147 Non -woven polyester mat coated with polymer modified asphalt and smooth surfaced. Non -woven polyster mat coated with polymer modified asphalt and surfaced with mineral granules. Non -Woven polyester mat coated with fire retardant polymer modified asphalt and surfaced with mineral granules. Non -Woven polyester mat coated with fire retardant polymer modified asphalt and surfaced with mineral granules. Heavy duty, polyester reinforced, asphalt modified bitumen membrane, smooth surface. Heavy duty, polyester reinforced, asphalt modified bitumen membrane, granule surface. i 1 ' Frank Zuloaga, Roofing Product Control Examiner Test Product Product Dimensions Specification Description Dekfast Lock Plate 3" x 3 1/4" Dekfast Fasteners #15 PA 114 Polypropylene locking plate. Manufacturer Construction Fasteners Inc. (with current PCA) PA 114 insulation fasteners for Construction concrete decks Fasteners Inc. (with current PCA) Dekfast Fasteners PA 114 insulation fastener for steel Construction #12 and wood decks. Fasteners Inc. (with current PCA) ISO 95+ Composite PA 110 Polyisocyanurate / perlite Firestone ridged insulation (with current PCA) Asphalt ASTM D 312 Type III or IV Hot asphlat generic bitumin adhesive Asphalt Primer ASTM D 41 Asphalt Primer `eneric EPS High Density Wood various Fiberboard various PA 110 Extruded polystyrene generic insulation PA 110 Wood fiber insulation board generic Pelite/Urethane various PA 110 Perlite / urethane composite generic Composite board insulation Perlite Insulation various PA 110 Perlite insulation board generic Polyethylene 4 mil min. Vapor barrier / Air barrier generic Red Rosin various Rosin paper for barrier generic layer on wood decks Roofing Nails Minimum # PA 114 Corrosion resistant annular generic 12 ring shank nails Page 11 of 61 u oaga, Roofutg Product Control Examiner Tin Caps Dens -Deck ISO 95+ E'NRG'Y -2 I SORoc Test Product Dimensions Specification MB aluminum roof coating #12 Roofgrip #14 Roofgrip Gripdek Fastener Hexcel Fastener Hextra Standard Plastic Plate Min. 32 ga. x various 3" round various various various PA 110 Page 12 of 61 Product Description Corrosion resistant circular discs. PA 121 Aluminum roof PA 110 Gypsum insulation board. PA 114 PA 114 Insulation fastener steel, wood or concrete decks PA 114 Insulation fastener PA 114 Insulation fastener Insulation fastener for steel or wood decks PA 114 Insulation fastener and metal or plastic plate PA 114 Polyolefin plastic plate PA 110 Polyisocyanurate foam insulation PA 1 10 Polyisocyanurate foam insulation Polyisocyanurate foam / rockwool composite insulation Nlanufacturer generic Grundy Industries (with current PCA) Georgia Pacific (with current PCA) ITW Buildex (with current PCA) ITW Buildex (with current PCA) ITW Buildex (with current PCA} ITW Buildex (with current PCA) ITW Buildex (with current PCA) ITW Buildex (with current PCA) International Permalite (with current PCA) NRG Barriers. Inc. (with current PCA) NRG Barriers. Inc. (with current PCA) Frank Zuloaga, Roofing Product Control Examiner Test Agency /Identifier Factory Mutual Research Corporation Factory Mutual Research Wind Uplift J.I. OT4AI.AM 08.26.92 Corporation FMRC 4470 - PA 1 14 Factory Mutual Research \Vind Uplift J.I. I V8A4.AM 06.28.93 Corporation FMRC 4470 - PA 114 Factory Mutual Research Wind Uplift J.1. 1 R I A6.AM 11.15.91 Corporation FMRC 4470 - PA 114 Factory Mutual Research Wind Uplift J.1. 0T2Q4.AM 10.17.91 Corporation FMRC 4470 - PA 114 Factory Mutual Research Wind Uplift J.1. 0Q6A6.AM 07.16.91 Corporation FMRC 4470 - PA 114 Factory Mutual Research Wind Uplift J.1. 3X3A2.AM 08.02.94 Corporation FMRC 4470 - PA 114 Factory Mutual Research \Vind Uplift J.1.0Y9Q5.AM 07.29.94 Corporation FMRC 4470 - PA 114 Factory Mutual Research Wind Uplift, FMRC J.1. IB9A8.AM 09.04.97 Corp. 4470 - PA 114 Factory Mutual Research Wind Uplift, FMRC J.I. 3D4Q2.AM 04.30.97 Corp. 4470 - PA 114 Trinity Engineering Wind Uplift PA 114 4483.04 97 -1 06.06.97 Underwriters Fire Resistance R1306, 87NK11819 01.01.93 Laboratories, Inc. Classification UL 790 - PA 114 Dynatech Engineering Corporation Current Insulation Attachment Requirements TEST REPORTS Name Rcpurt Wind Uplift PA 114 Page 16 of 61 Date FMRC 1996 01.01.96 #3600.02.95 -1 02.02.95 rank Zuloaga, Roofing Product Control Examiner Test Name Report Agency/Identifier Dynatech Engineering Corporation Wind Uplift PA 114 %:4182.02.95 -1 Page 17 of 61 Date 02.02.95 Zuloaga, Roofing Product Control Examiner Membrane Type: SBS Deck Type 1: Wood, Non - insulated New Construction or Reroof Deck Description: 19 / x= " or greater plywood or wood plank decks System Type A(2): Base sheet mechanically fastened. All General and System Limitations shall apply. Maximum Design Pressure: -45 psf (See General Limitation #7) Maximum Fire Classification: 'A'. See General Limitation #2. Maximum Slope: 2 ":12 "; See General Limitation #3. Specification No.: Page 22 of 61 Base Sheet: GAFGLAS® #75, GAFGLAS #80 Ultima Base Sheet, GAFGLAS® PLY 4®, GAFGLAS PLY 60, GAFGLAS FlexPly Base Sheet,GAFGLAS® STRATAVENT® Nailable, RUBEROID Modified Base Sheet or RUBEROID® 20 applied to the deck with approved annular ring shank nails and minimum I ' /," tin caps at a fastener spacing of 9" o.c. at the lap, 12" o.c. in two rows staggered along the center line of the sheet in the field. PIy Sheet: (Optional) One, two, or three plies GAFGLAS PLY 4®, GAFGLAS® PLY 601) PIy or GAFGLAS Flex Ply 6 sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20 -40 lbs. /sq.. Membrane: One or more plies of RUBEROID MOP Smooth, Ruberoid® Mop 170 FR, Ruberoid® Mop Granule, Ruberoid® Mop Plus Granule, Ruberoid® 30 or Ruberoid® 30 FR or Ruberoid® Mop FR or RUBEROID UltraCladTM SBS in adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20 -40 lbs. /sq.. Or, One or more plies of RUBEROID MOP Smooth, RUBEROID® Mop Granule, RUBEROID® Mop 170 FR. RUBEROID® Mop Plus Granule, RUBEROID® 30, RUBEROID® 30 FR or RUBEROID® Mop FR or RUBEROID UltraCladTM SBS in RUBEROID Modified Bitumen Adhesive at an application rate of 1 -2 gal. /sq. Surfacing: (Optional, required if RUBEROID MOP Smooth or RUBEROID 20 is top membrane) Install one of the following: 1. Gravel or slag applied at 400 lb./sq. and 300 lbisq. respectively in a flood coat of approved asphalt at 60 lb./sq.. 2. GAFGLAS Mineral Surfaced Cap Sheet in an approved asphalt at an application rate of 25 lb. /sq. + 15 %. Frank Zuloaga, Roofing Product Control Examiner Wood Deck System Limitations: 1. Fastener spacing for anchor sheet attachment is based on a Minimum Characteristic Force (F') of 95 lbf or greater as tested in compliance with Merto -Dade County Protocol PA 105. If F' as tested is below 95 lbf, a professional engineer may submit a revised fastener spacing utilizing the withdrawal resistance value taken from Merto -Dade County Protocol PA 105 and calculations in compliance with Metro -Dade Roofing Application Stanadrd PA 117. 2 All standard insulation panel sizes are acceptable for mechanical attachment. When panels are applied in hot asphalt, maximum panel size shall be 4' x 4'. a. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F') of 275 lbf. as tested in compliance with Merto -Dade County Protocol PA 105 & Roofing Application Standard PA 117. If the fastener value, as field tested, are below 275. lbf. insulation attachment shall not be acceptable. 3 A slip sheet is required with GAFGLAS FlexPly 40 and Ply 60 when used as a mechanically fastened base or anchor sheet. 4. Y2 Type X gypsum board is acceptable to be installed directly over the wood deck.. 4: .4 . Page 57 of 61 Frank Zuloaga, Roofing Product Control Examiner GENERAL LIMITATIONS 1 All asphalt shall comply with ASTM D 312 type III or type IV requirements, and approved by applicant. 2 Fire ratings are determined by a combination of slope, deck type and assembly. Refer to current Underwriters Roofing Materials Directory or other fire testing data listed in the testing file. Fire ratings shall be in strict compliance with Sections 3401.5 and 3401.6 of the South Florida Building Code. 3 Maximum slope range shall vary for each system; consult current Underwriters Laboratories Roofing, Materials Directory and manufacturer's specifications for compliance with design criteria for each project. 4 An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped. If no recovery board is used, install one layer of GAFGLASS STRATAVENT Perforated, laid dry.A base sheet may be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at each sidelap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 12 lbs. /sq. Note: Spot attached systems shall be limited to a maximum design pressure of -45 psf. Where STRATAVENT Perforated is used over approved isocyanurate foam insulation, the maximum design pressure is limited to — 60psf. 5 All work shall be performed by a contractor licensed to do roofing work in Metro - Dade County. Contractor shall be familiar with the details and specifications published by the manufacturer, and the requirements of the SFBC. 6 The submission of system specifications and details shall accompany the Section II Building Code Permit. This information is available in the publications listed in the 'System Description' of this Product Control Approval. The submission of these documents, as well as the proper application and installation of all materials shall be the sole responsibility of the contractor. Page 58 of 61 Zuloaga, Roofing Product Control Examiner 7 Perimeter and corner areas shall comply with the enhanced uplift pressure of these areas, as calculated in compliance with Chapter 23 of the South Florida Building Code. Fastener densities shall be increase for both insulation and base sheet as needed calculated in compliance with Metro - Dade County Roofing Application Standard PA 117. (When this limitation is specifically referred within this NOA, General Limitation #20 will not be applicable.) 8 All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs shall conform with Metro - Dade County Roofing Application Standard PA 111 and the wind load requirements of Chapter 23 of the South Florida Building Code. 9 Flashings shall be installed according to the manufacturers standard details, and may be applied in cold application adhesive, approved asphalt or may be applied in conjunction with an approved torch applied modified bitumen membrane. Specific details, approved by the manufacturer, shall be submitted with the Section II Permit Application. All details shall comply with the provision of the South Florida Building Code. 10 Fastener spacing for base sheet attachment is based on a Minimum Characteristic Force (F') value as tested in compliance with Metro -Dade Counry Protocol PA 105. If the fastener values as tested are below those listed in the System Limitations, a professional engineer may submit a revised fastener spacing utilizing the withdrawal resistance value taken from a Metro - Dade County Protocol PA 105 test report and calculations that comply with the wind Toad requirements of Chapter 23 of the South Florida Building Code and Roofing Application Standard PA 117. 11 Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F') value of 275 lbf., as tested in compliance with PA 105. If the fastener value, as field tested, are below 275 lbf. insulation attachment shall not be acceptable. 12 Asphalt moppings shall be with applied with approved asphalt and shall be in compliance with equiviscous temperature (EVT) methods of asphalt determination. Asphalt containers or bulk tickets shall indicate an EVT, finished blowing temperature (FBT) and flash point. Asphalt types and temperature ranges shall be in compliance with Subsection 3403.4(aX3) of the South Florida Building Code. 13 Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs.sq., or mechanically attached using the fastening pattern of the top layer. Refer to manufacturer's literature and/or the NRCA Roofing and Waterproofing Manual for correct application procedures of insulation panels in approved asphalt or adhesive, which shall comply with provision of Roofing Application Standard PA 117 Page 59 of 61 rank Zuloaga, Roofing Product Control Examiner 14 All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size shall be 4' x 4' maximum. 15 In re- covery/re- roofing applications, prior to the application, all existing roof surfaces used as a bonding substrate shall be tested in compliance with Metro -Dade County Protocol PA 124 for uplift resistance. Test pressures shall be calculated in compliance with the wind load requirements of Chapter 23 of the South Florida Building Code to the design pressure of the roof. 16 In re- roofing applications, moisture content in an existing roof must be in compliance with Section 3401.10(m), (n) of the South Florida Building Code. 17 Roll good materials shall be stored on end and on a clean, flat and dry surface. 18 If required, any Factory Mutual Approved vapor barrier in conjunction with proprietary or approved adhesives may be used prior to the application of the insulation layer. 19 Consult current Underwriters Laboratories Directory for the appropriate coating for each roofing assembly to obtain the required fire rating. The assembly shall be installed in strict compliance with sections 3401.5 and 3401.6 of the South Florida Building Code for maximum fire classification. 20 The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field, perimeters, corners). No rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners, and corners). (When this limitation is specifically referred within this NOA, General Limitation #7 will not be applicable.) Page 60of61 rank Zuloaga, Roofing Product Control Examiner c : 3 : GAF Materials Corporation ACCEPTANCE NO.: 97- 0814.14 1361 Alps Road APPROVED: November 6. 1997 Wayne, NJ 07470 EXPIRES: November 6, 2000 NOTICE OF ACCEPTANCE STANDARD CONDITIONS Renewal of this Acceptance (approval) shall be considered after a renewal application has been filed and the original submitted documentation, including test supporting data, engineering documents, are no older than eight (8) years. 1 2 Any and all approved products shall be permanentlx labeled with the manufacturer's name, city, state, and the following statement: "Metro -Dade County Product Control Approved ", or as specifically stated in the specific conditions of this Acceptance. 3 Renewals of Acceptance will not be considered in a) There has been a change in the South Florida Building Code affecting the evaluation of this product and the product is not in compliance with the code changes; b) The product is no longer the same product (identical) as the one originally approved; c) If the Acceptance holder has not complied with all the requirements of this acceptance, including the correct installation of the product; d) The engineer who originally prepared, signed and sealed the required documentation initially submitted, is no longer practicing the engineering profession. 4 Any revision or change in the materials, use, and/or manufacture of the product or process shall automatically be cause for termination of this Acceptance, unless prior written approval has been requested (through the filing of a revision application with appropriate fee) and granted by this office. 5 Any of the following shall also be grounds for removal of this Acceptance: a) Unsatisfactory performance of this product or process; b) Misuse of this Acceptance as an endorsement of any product, for sales, advertising or any other purposes. 6 The Notice of Acceptance number preceded by the words Metro -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the Notice of Acceptance is displayed, then it shall be•done in its entirety. 7 A copy of this Acceptance as well as approved drawings and other documents, where it applies, shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at all times. The copies need not be resealed by the engineer. 8 Failure to comply with any section of this Acceptance shall be cause for termination and removal of Acceptance. 9 This Acceptance contains pages 1 through 61 END OF THIS ACCEPTANCE Page 61 of 61 Frank Zuloaga, Roofing Product Control Examiner PERMIT APPLICATION FOR MUNICIPALITIES OF DADE COUNTY (OWNER TO RETAIN COPY) Date 0 Job Address � Ag7 A2a 5t Tax Folio Legal Description . // 47` , '// Master Permit #3�g' Owner / Lessee / Tenant 4 /a6Z `ilhetr•4kE'/t Owner's Address � /D �j/ Phone v3 l993 Contracting• Co. 1(26, e'007 Address ;73.f5"7.11 /L ,',4 L% Qualifier � h / I ? e S A (06e ,Jac.)r SSA Phone .. ,,i77---;14, (2 State° 4 1 Q " J 004 clary Ins. Co. Architect /Engineer Address ' Bonding Company MoLt3agor Square Ft. gOoo Zoning gn.it� %e of Owner d /or Condo • Date Notary as to Owner an• /oi• Condo President My Commission Expires: • * . * . * * L4trto oNFiorida CohiidsiBF��[�& q PERMIT FEE: APPROVED: Feb. 18, F �gl'e Mechanical Plumbing Address • Address Permit (circle one): = ILDIN ELECTRICAL PLUMBING MECHANICAL) PAVING FENCE SI( WORK DESCRIPTION Sr #-f( 3p — wke /r►Tle_ citswt V I Estimated Cost 1 $ 0 !?b5 cry WARNING TO OWNER: YOU MUST RECORD A NOTICE OF COMMENCEMENT AND YOUR FAILURE Z DO SO MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY (IF YC INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT). �.. Application is hereby made to obtain a co work and installation as indicated above, at on tact attached addendum (if applicable). I certify that all work will be performed to meet ti staniards of all laws regulating construction in this jurisdiction. I understand that separat permits are required tor ELECTRICAL, PLUMBING, SIGNS, POOLS, ROOFING, and MECHANICAL work. OWNEa'S AFFIDAVIT: I certify that all the foregoing information'is accurate and that all vox d. will be done in compliance with all applicable laws regulating construction and zoning Furt •iermore, 1 authori:s:ei the above - names c:oiAtrac or to do the work stated. Owner- Builder Notary as to Contractor o wner -Bu My Commission Expires: �k �k *k *k * * P(otary Pdt�P€ to of Florida 0th !I ' _ .0i N %V Electrical Engineering Application is hereby made for the approval of the detailed statement of the plans and specifications herewith submitted for the building or other structure herein described. This application is made in compliance and conformity with the Building Ordinance of Miami Shores Village, Florida, and all provisions of the Laws of the State of Florida, all ordinances of Miami Shores Village and all rules and regulations of the Building Division of Miami Shores Village shall be complied with. whether herein specified or not. A copy of approved plans and specifications must be kept at building during progress of the work. Owner's Name and Address Registered Architect and/or Engineer Name and address of licensed contractor 0..l A uez G-- ER"; .f. ..q Location and le al description of lot to be built on: �^ AMP 'f Lot V V Block // Subdivision /7Y i A v ii (0` / Pile Street and Number where work is to be done ti L � 1V E Lto3 S{ State work to b e and purpose of building (by floors), state exterior colors (submit samples) —\ 1 2 � . �- S. and for no other purpose. New Building Remodeling Addition Repairs No. of Stories To be constructed of Kind of foundation Roof Covering Estimated Total cost of improvements $ A -N Amount of Permit $ „1O0421 Zone cubage required Plan Cubage Distance to next nearest building Size of Building Lot Maximum live load to be borne by each floor I hereby submit all plans and specifications for said building. All notices with reference to the building and its construction may be sent to The undersigned applicant for this building permit does hereby certify that he understands and accepts his obligatons as an employer of Labor under the Florida Workmen's Compensation Act, being Section 5966, Compiled General Laws of Florida, Permanent Supplement, and has complied with the provisions thereof, and will require similar compliance from all contractors or sub - contractors employed by him in the work to be performed under this permit; a will post or cause to be posted for inspection on the site of the work such public notice or notices as are required by the Act. The undersign agrees to employ on such subcontractors, on work to be performed under this permit, as are licensed by Miami Shores Village. Remarks (Signed) STATE OF FLORIDA COUNTY OF DADE. } ss. Before me. the undersigned authority, a notary public, duly authorized to administer oaths and take acknowledgments, personally appeared to me well known. and who. being by me first duly sworn, upon oath deposes and says that he is the of the above described construction. that he has carefully read the foregoing application, and that he did sign the same, and that all facts therein by him stated are true. Date //f rT /R Read, Sworn to and Subscribed before me. Permit No. el 7 77A MIAMI SHORES VILLAGE BUILDING INSPECTION DEPARTMENT APPLICATION FOR BUILDING PERMIT Disapproved (\ j .ts r J Date Date 1 114-111 193- - No. S L - I r �� �treet l Jd s4 Notary Public, State of Florida (Signed) 'V ` " Building Inspector My Commission Expires PLANNING BOARD DATE Chairman Member Member Member Member Member Council Approved Date Disapproved NOTE: A charge of $25.00 will be made for making corrections or changes to this application after approval has been obtained from the Planning A re- inspection fee of $25.00 will be charged when such re- inspection is made necessary by improper notice for inspection or faulty materials and/or Chairman Member --------------- - - -- Member ._ Council Approved MIAMI SHORES VILLAGE BUILDING INSPECTION DEPARTMENT APPLICATION FOR BUILDING PERMIT Application is hereby made for the approyal of the detailed statement of the plans and specifications herewith submitted for the build- ing or other structure herein described. This application is made in compliance and conformity with the Building Ordinance of Miami Shores Village, Florida, and all provisions of the Laws of the State of Florida, all ordinances of Miami Shores Village and all rules and regulations of the Building Division of Miami Shores Village shall be complied with, whether herein specified or not. A copy of approved plans and specifications must be kept at building during progress of the work. Owner's Name and Address Registered Architect and /or Engineer I �-- Name and address of licensed contractor '�- 4 Location and legal description of lot to be built on: Lot Block Subdivision Street and Number where work is to be done -6 ee:: ./e a2..____,,e - State work to be done and purpose of building (by floors) / /Ad. • and for no other purpose. New Building Remodeling Addition Repair No. o Storiess / To be constructed of Kind of foundation Roof Covering_ 3/��(� , -17 Estimated Total cost of improvements $ J 6. 6o• i Amount of Permit $ , Zone cubage required Plan Cubage __.. Distance to next nearest building Size of Building Lot A7 Maximum live load to be borne by each floor I hereby submit all the plans and specifications for said building. All notices with reference to the building and its construction may be sent to The undersigned applicant for this building permit does hereby certify that he understands and accepts his obligations as an employer of labor under the Florida Workmen's Compensation Act, being Section 5966, Compiled General Laws of Florida, Pennanent Supplement, and has complied with the provisions thereof, and will require similar compliance from all contractors or sub- contractors employed by him in the work to be performed under this permit; and will post or cause to be posted for inspection on the site of the work such public notice or notices as are required by the Act. The undersigned agrees to employ only such sub tractors, on work to be performed u t permit, as are licensed by Miami Shores Village. �� Remarks___ (Signed l°t'�_e PLANNING BOARD DATE Member Member . 7 ,19 01 No Street -__ -/ Q STATE OF FLORIDA, COUNTY OF DADE. ss Before me, the undersigned authority, a notary public, duly authorized to administer oaths and take acknowledgments, personally ap- peared to me well known, and who, being by me first duly sworn, upon oath deposes and says that he is the_ of the above described construction, that he has carefully read the foregoing application, and that he did sign the same, and that all facts therein by him stated are true. r/ Permit No._ i `� 0 ? � Date ! ( � b Read, Sworn to and Subscribed before me. Disapproved __ __ __ Date _ _ ( Signed) (( �' °'� 9_ _ (- Notary Public, State of Florida (;. �? i Building In ector My Commission Expires Member Date Disapproved Date NOTE: A charge of $1.00 will be made for making corrections or changes to this application after approval has been obtained from the Planning Board. A re- inspection fee of $1.00 will be charged when such re- inspection is made necessary by improper notice for inspection or faulty materials and /or workmanship. BUILDING ❑ ELECTRICAL ❑ PLUMBING ❑ ROOFING ❑ Owner Building C N ( A ) }l * T A PERMIT N? 10524 Architect Contractor or Builder z + 1 •— 114045, t t Cs Legal Lot 1 Description � BI Address of *1 •" c Building �` t MIAMI SHORES VILLAGE, FLORIDA Work to be performed under this Permit This permit is granted to the contractor or builder named above to construct the building or to install the equipment or device described in the applica- tion herefor in strict compliance with all ordinances pertaining thereto and with the understanding that the work will be performed in compliance with any plans, drawings, statements or specifications that may have been submitted to and approved by the proper municipal authorities. This Permit may be revoked at any time if the work is not done in compliance with such ordinances or if the plans are changed without authorization. A further condition upon which this permit is granted is the understanding that the contractor or builder named above assumes the responsibility for a thorough knowledge of the ordinances and regulations pertaining to the work covered hereby whether shown on the plans or drawings or in the statements or specifications and that he assumes respon- sibility for work done by his agents, servants or employees. ri t 9, Signet' f t" t C" (INSPECTOR) BY In consideration of the issuance to me of this permit agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, wings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all w done by either, myself, m agent, servant or employee. �� 11 s Subdi- Date l f 19 u" Contractor's License No. vision Sq Ft. Value of =_' 11 Amount of Project $ 1 „ 11 Permit $ J ' It Jl c' +u 6.) rM + . CONTRACTOR or BUILDER BY AUTHORITY Village% of Miami Shores JOB �i c-ti ADDRESS 4.- `( INSPECTION 7`) 1 T ff- /c c .� N° 4110 TIME READY REMARKS INSPECTOR DATE BUILDING ELECTRICAL PLUMBING ROOFING Owner of Building Architect Contractor or Builder Legal Description Address of Building Lot Et CONTRACTOR OR BUILDER MIAMI SHORES VILLAGE. FLORIDA PERMIT ■9 3539 B1 Value of Amount of Project $ Permit $ 195 DATF Contractor's License No. Work to be performed under this Permit Subdi- vision This permit is granted to the contractor or builder named above to construct the building or to install the equipment or device described in the application herefor in strict compliance with all ordinances pertaining thereto and with the understanding that the work will be performed in compliance with any plans, drawings, statements or specifications that may have been submitted to and approved by the proper municipal authorities. This Permit may be revoked at any time if the work is not done in compliance with such ordinances or if the plans are changed without authorization. A further condition upon which this permit is granted is the understanding that the contractor or builder named above assumes the responsibility for a thorough knowledge of the ordinances and regulations pertaining to the work covered hereby whether shown on the plans or drawings cr in the statements or specifications and that he assumes responsibility for work done by his agents, servants or employees. Signed BY INSPECTOR In consideration of the issuance to me of this permit I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In ac- cepting this permit I assume responsibility for all . work done by either, myself, my agent, servant or employee. BY AUTHORITY a BUILDING ELECTRICAL ❑ PLUMBING ❑ ROOFING ❑ ❑ Owner of Building Architect Contractor or Builder Legal Lot Description Address of Building MIAMI SHORES VILLAGE. FLORIDA CONTRACTOR OR BUILDER PERMIT N? 3436 / B1 Work to be performed under this Permit / s�f BY DATE 195 Contractor's License No. Subdi- vision Value of Project $ / 2- Amount of Permit $ This permit is granted to the contractor or builder named above to construc the building or to install the equipment or device described in the application herefor in strict compliance with all ordinances pertaining thereto and with the understanding that the work will be performed in compliance with any plans, drawings, statements or specifications that may have been submitted to and approved by the proper municipal authorities. This Permit may be revoked at any time if the work is not done in compliance with such ordinances or if the plans are changed without authorization. A further condition upon which this permit is granted is the understanding that the contractor or builder named above assumes the responsibility for a thorough knowledge of the ordinances and regulations pertaining to the work covered hereby whether shown on the plans or drawings or in the statements or specifications and that he assumes responsibility for work done by his agents, servants or employees. f Signed. BY 1' _ INSPECTOR In consideration of the issuance to me of this permit I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto 'and in strict c�o �, !�..�. ity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In ac- cepting this perm e i it - ass .. ∎.ility for all work done by either, myself, my agent, servant or employee. AUTHORITY o, Owner's Name and Add ss.. STATE OF FLORIDA, COUNTY OF DADE. ss MIAMI SHORES VILLAGE BUILDING INSPECTION DEPARTMENT APPLICATION FOR BUILDING PERMIT Application is hereby made for the approyal of the detailed statement of the plans and specifications herewith submitted for the build- ing or other structure herein described. This application is made in compliance and conformity with the Building Ordinance of Miami Shores Village, Florida, and all provisions of the Laws of the State of Florida, all ordinances of Miami Shores Village and all rules and regulations of the Building Division of Miami Shores Village shall be complied with, whether herein specified or not. A copy of approved plans and specifications must be kept at building during progress of the work. Registered Architect and /or Engineer /. Name and address of licensed contractor �P Location and legal description of lot to be built on: Lot Block � Subdivision Street and Number where work is to be done � .. / G _ State ork to be done and purpos of building (by oors) Q 4 4:77- '> '- ��, '7 and for no other purpose. �� Date No._.�l ' New Building Remodeling Addition Repairs No. of Stories 1 To be constructed of Kind of foundation Roof Covering Estimated Total cost of improvements $ I O °—° Amount of Permit $ Zone cubage required -Plan Cubage Distance to next nearest building Size of Building Lot Maximum live load to be borne by each floor I hereby submit all the plans and specifications for sai building. All notices with reference to the building and its construction may be sent to � ..... . .... .. . .... The undersigned applicant for this building permit does hereby certify that he understands and accepts his obligations as an employer of labor under the Florida Workmen's Compensation Act, being Section 5966, Compiled General Laws of Florida, Pennanent Supplement, and has complied with the provisions thereof, and will require similar compliance from all contractors or sub - contractors employed by him in the work to be performed under this permit; and will post or cause to be posted for inspection the site of the work such public notice or notices as are required by the Act. The undersigned agrees to employ only uch subcontrac on work2to . .erform•d under thi permit, as are licensed by Miami Shores Village. Remarks " —( Before me, the undersigned authority, a notary public, duly authorize o administer oaths and take acknowledgments, personally ap- peared to me well known, and who, being by me first duly sworn, upon oath deposes and says that he is the of the above described construction, that he has carefully read the foregoing application, and that he did sign the same, and that all facts therein by him stated are true. Permit No 4C - Z 7 Date 41 /d rcrt Read, Sworn to and Subscribed before me. Disapproved Dat ( Signed) 4- Buildinylespector My Commission Expires Notary Public, State of Florida / h ✓�� , 19 �., ." stree1 .�C _� 0 PLANNING BOARD DATE Chairman Member Member Member Member Member Council Approved Date Disapproved Date NOTE: A charge of $1.00 will be made for making corrections or changes to this application after approval has been obtained from the Planning Board. A re-inspection fee of $1.00 will be charged when such re- inspection is made necessary by improper notice for inspection or faulty materials and/or workmanship. APPLICATION FOR BUILDING PERMIT Application is hereby made for the approval of the detailed statement of the plans and specifications herewith submitted for the build- ing or other structure herein described. This application is made in compliance and conformity with the Building Ordinance of Miami Shores Village, Florida, and all provisions of the Laws of the State of Florida, all ordinances of Miami Shores Village and all rules and regulations of the Building Division of Miami Shores Village shall be complied with, whether herein specified or not. A copy of approved plans and specifications must be kept a' building during progress of the work. Owner's Name and Address..! Registered Architect and /or Engin Name and address of licensed contractor Location and legal description of lot to be built on: Lots. 4 C Block // Sjjbdivision Street and Number where work is to be done State work to be done and purpo a of building (by floors) be sent to STATE OF FLORIDA, COUNTY OF DADE. J ss MIAMI SHORES VILLAGE BUILDING INSPECTION DEPARTMENT and for no other p urpose. New Building Remodeling Addition ot--" Repairs No. of Stories . / To be constructed of Kind of foundation Roof Covering o. Estimated Total cost of improvements $ 7 d Amount of Permit $ Zone cubage required _Plan Cubage Distance to next nearest building Size of Building Lot Maximum live load to be borne by each floor I hereby submit a plans and specifications for said building. All notices with reference to the building and its construction may F /A ■- — The undersigned applicant for this building pennit does hereby certify that he understands and accepts his obligations as an employer of Labor under the Florida Workmen's Compensation Act, being Section 5966, Compiled General Laws of Florida, Permanent Supplement, and has complied with the provisions thereof, and will require similar compliance from all contractors or sub - contractors employed by him in the work to be performed under this permit; and will post or cause to be posted for inspection on the site of the work such ppublic notice or notices as arc required by the Act. The undersigned agrees to employ only such sybfontractors, on work to bg gerformes1 wader this permit, as are licensed by Miami Shores Village. Remarks (Signed V7 , 19s — Street __ 1 Before me, the undersig authority, a notary public, dul, tni[1 'zed to 'nister oaths and take acknowledgments, personally ap- peared to me well known, and who, being by me first duly sworn, upon oath deposes and says that he is the . of the above described construction, that he has carefully read the foregoing application, and that he did sign the same, and that all facts therein by him stated are true. Permit No Date to and Su .tribe Disapproved Date — otary Public, State of El ila Notary Public, St , o; l ler :dn ct k g (Signed) My commission exoir�:; Mwr. 1. 1; Building Inspector My Commission Expires i;onded by American Smre4y Co. of N. Y. PLANNING BOARD DATE Chairman Member Member Member Member Member Council Approved Date Disapproved Date NOTE: A charge of $1.00 will be made for making corrections or changes to this application after approval has been obtained from the Planning Board. A re- inspection fee of $1.00 will be charged when such re- inspection is made necessary by improper notice for inspection or faulty materials and /or workmanship.