RC-10-940Project Address Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL 33138 -0000 Phone: (305)795 -2204 Parcel Number 490 NE 102 Street Miami Shores, FL 33138- 1132060170550 Block: Lot: CURRENT OCCUPANT OR OWN CURRENT OCCUPANT OR OWNERS 490 NE 102 Street MIAMI SHORES FL 33138 -3219 Contractor(s) HOME OWNER Phone Cell Phone Approved: Yes Comments: Date Approved: 5/26/2010 : Yes Date Denied: Type of Construction: SHED INSTALLATION Stories: Front Setback: Left Setback: Bedrooms: Plans Submitted: Certificate Date: _Bond Retum : Occupancy: Single Family Exterior: Rear Setback: Right Setback: Bathrooms: Certificate Status: Additional Info: Classification: Residential Fees Due CCF Education Surcharge Notary Fee Permit Fee - Additions/Alterations Scanning Fee Technology Fee Total: Amount $0.60 $0.20 $5.00 $100.00 $6.00 $0.80 $112.60 In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL PLUMBING, MECHANICAL WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Futhermore, 1 authorize the above -named contractor to do the work stated. Authorized Signature: Owner / Applicant / Contractor / Agent Building Department Copy Pay Date Pay Type Invoice # RC -5 -10 -37992 06/11/2010 Credit Card 05/25/2010 Credit Card Amt Paid Amt Due $ 62.60 $ 50.00 $ 50.00 $ 0.00 Applicant Valuation: Total Sq Feet: $ 250.00 80 1 Available Inspections: Inspection Type: Slab Final June 11, 2010 Date June 11, 2010 1 61410 BUILDING PERMIT APPLICATION FBC 20 Permit Type: BUILDING ROOFING Owner's Name (Fee Simple Titleholder)/ n (S C _ ;r, / r r S PhoU# 30S 360o ( (WI Owner's Address L K/0 A ' //9 , �--' / City /4- sb� rI . State /py Zip 013 Tenant/Lessee Name � Phone #°' 3e0 61 19Y Email — 772/ 2 -1 2 -4.5 e- / 9 .�. n Job Address (where the work is being done) 419 (e) /DO City Miami Shores Village County Miami -Dade Zip 3 1 3 r FOLIO / PARCEL # Is Building Historically Designated YES NO X Flood Zone a Contractor's Company Name Contractor's Address City State Zip Qualifier Name Phone # State Certificate or Registration No. Certificate of Competency No. Contact Phone Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 INSPECTION'S PHONE NUMBER: (305) 762.4949 Permit No. tZC \0" ' O Master Permit No. E -mail Phone # °""1 2 .ri 201Q BY: ��.. Architect/Engineer's Name (if applicable) Phone # Value of Work For this Permit $ c tf:ReW Square / Linear Footage Of WorkS'< L 0 Type of Work: ❑Add y itiion ❑Alteration Tew J ❑ Repair/Replace ❑ Demolition Describe Work: /4674a// Q /eest 1 /G'G ! 5/1e0 l c- Aso 7 fircdo erg * * * * * * * * * * * * * * * * * ** * * * * * * * * * ** *** * * ** F ees * * * ** ******* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** C {�� ©aa Submittal Fee $ - vO J Permit Fee $ ZO CCF $ 0 ta0 CO /CC $ Notary $ 5-00 Training/Education Fee $ 0 Technology Fee $ 0.80 Scanning $ CO Radon $ DPBR $ Bond $ Double Fee $ Violation date: ,� Structural Review. $ Total Fee Now Due $ (t I `a° See Reverse side -* Bonding Company's Name (if applicable) Bonding Company's Address City 1 r Mortgage Lender's Name (if applicable) ( Mortgage Lender's Address City State Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signatur Owner or Agent Contractor The forego I g instrumenttwas ac . ledged before m this The foregoing instrument was acknowledged before me this day o i " ,20 IQ, by / � ? . r , . ay of ,20_,by gZ) who is, ersona y kk o//ffw��n to me or who has produced who is personally known to me or who has produced � 1, ' • c^ V1 identification and who did take an oath. as identification and who did take an oath. NOT PUBLIC: Sign: Print: My Commission Expires: APPROVED BY (Revised 07 /10 /07XRevised 06 /10/2009) State Zip _ Plans Examiner Engineer NOTARY PUBLIC: Signature Sign: Print: My Commission Expires: Clerk checked NA OWNER BOIL% R + ISCLOSURE STATEMENT TE: Miami Shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 ADDRESS: / az st_ Do hereby petition the Village of Miami Shores to act as my own contractor pursuant to the laws of the State of Florida, F.S 489.103(7). And I have read and understood the following disclosure statement, which entitles me to work as my own contractor, I further understand that I as the owner must appear in person to complete all applications. State Law requires construction to be done by a licensed contractor. You have applied for a permit under an exception to the law. The exemption allows you, as the owner of your property, to act as your own contractor even though you do not have a license. You must supervise the construction yourself. You may build or improve a one - family or two- family residence. You may also build or improve a commercial building at a cost of $25,000.00 or less (The new form states 75,000). The building must be for your own use and occupancy. It may not be built for sale or lease. If you sell or lease a building you have built yourself within one year after the construction is complete. the law will presume that you built for sale or lease, which is a violation of this exemption. You may not hire an unlicensed person as a contractor. It is your responsibility to make sure the people employed by you have licenses required by state law and by county or municipal licensing ordinances. Any person working on your building who is not licensed must work under your supervision and must be employed by you, which means that you must deduct F.I.C.A and with- holdings tax and provide workers' compensation for that employee, all as prescribed by law. Your construction must comply with all applicable laws, ordinances, buildings codes and zoning regulations. Please read and initial each paragraph. 1. I understand that state law requires construction to be done by a licensed contractor and have applied for an owner - builder permit under an exemption from the law. The exemption specifies that I, as the owner of the property listed, may act as my own contractor with certain restrictions even though I do not have a license. Initial Orin 2. I understand that building permits are not required to be signed by a property owner unless he or she is responsible for the construction and is not hiring a licensed contractor to assume responsibility. Initial 3. I understand that, as an owner builder, I am the responsible party of record on a permit I understand that I may protect myself from potential financial risk by hiring a licensed contractor and having the permit filed in his or her name instead of my own name. I also understand that the contractor is required by law to be licensed in Florida and to list his or license numbers on permits and contracts. 5. I understand that, as the owner- builder, I must provide direct, onsite supervision of the construction. Initial Initial Initial 4. I understand that I may build or improve a one family or two-family residence or a farm outbuilding. I may also build or improve a commercial building if the costs do not exceed $75,000. The building or residence must be for my use or occupancy. It may not be built or substantially improved for sale or lease. If a building or residence that I have built or substantially improved myself is sold or leased within 1 year after the construction is complete, the law will presume that I byit or substantially improved it for sale or lease, which violates the exemption. Initial I understand that I may not hire an unlicensed person to act as my contractor or to supervise persons working on my building or residence. It is my responsibility to ensure that the persons whom I employ have the license required by law and by county or municipal ordinance. 7. I understand that it is frequent practices of unlicensed persons to have the property owner obtain an owner - builder permit that erroneously implies that the property owner is providing his or her own labor and materials. I, as an owner- builder, may be held liable and subjected to serious financial risk for any injuries sustained by an unlicensed person or his or employees while working on my property. My homeowner's insurance may not provide coverage for those injuries. I am willfully acting as an owner- builder and am aware of the limits of my insurance coverage for injuries to workers on my property. 8. I understand that I may not delegate the responsibility for supervising work to be a licensed contractor who is not licenses to perform the work being done. Any person working on my building who is not licensed must work under my direct supervision and must be employed by me, which means that I must comply with laws requiring the withholding of federal income tax and social security contributions under the Federal Insurance Contributions Act (FICA) and must provide workers compensation for the employee. I understand that my failure to follow these may subject to serious financial risk. 9. I agree that, as the party legally and financially responsible for this proposed Construction activity, I will abide by all applicable laws and requirement that govern owner - builders as well as employers. I also understand that the Construction must comply with all applicable laws, ordinances, building codes, and zoning regulations. 10. I understand that I may obtain more information regarding my obligations as an employer from the Internal Revenue Service, the United States Small Business Administration, and the Florida Department of Revenues. I also understand that I may contact the Florida Construction Industry Licensing Board at 850.487.1395 or http:// www. mvfloridalicense .com/dbpr /Drolcilbfindex.html 11. I am aware of, and consent to; an owner - builder building permit applied for in my name and understands that I am the party legally and financially responsible for the proposed construction activity at the following address: 12. I agree to notify Miami Shores Village immediately of any additions, deletions, or changes to any of the info have provided on this disclosure. Licensed contractors are regulated by laws designed to protect the public. If you contract with a person who does not have a license, the Constr4uction Industry Licensing Board and Department of Business and Professional Regulation may be unable to assist you with any financial loss that you sustain as a result of contractor may be in civil court. It is also important for you to understand that, if an unlicensed contractor or employee of an individual or firm is injured while working on your property, you may be held liable for damages. If you obtain an owner - builder permit and wish to hire a licensed contractor, you will be responsible for verifying whether the contractor is properly licensed and the status of the contractor's workers compensation coverage. Before a building permit can be issued, this disclosure statement must be completed and signed by the property owner and returned to the Total permitting agency responsible for issuing the permit. A copy of the property owner's driver license, the notarized signature of the property owner, or other type of verification acceptable to the local permitting agency is required when the permit is issued. Was acknowledged before me this day of BYSeJ 4mird Produced there License or 2010 who was personally known to me or who has l' (0) "' as identification. O NER NOTARY NOTM 77141,7,C-C7ATE 4.7 FLORIDIk ..a,� Ci il' V C?4 �1€�ra Di 17123 BONDED MU ATLANTIC BONDING CO., INC. Initial Initial ijeD Initia !nit' Initial Planning and Zoning Criteria Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL 33138 -0000 Phone: (305)795 -2204 Fax: (305)756 -8972 Owner's Name: CURRENT OCCUPANT OR OWNERS Job Address: 490 102 Street Miami Shores, FL 33138- Planning and Zoning Criteria and Comments Approved: Yes Date Approved: 5/26/2010 : Yes Comments: Issue Date: Not Issued Folio Number:1132060170550 Owner's Phone: Total Square Feet: Total Job Valuation: Contractor(s) HOME OWNER Phone Primary Contractor Yes 80 $ 250.00 • ••• • • •••t• • • • • ••• • • .••r• • • • ••• • Legal Description: Lot 1 and 2, Block 91, of MIAMI SHORES SECTION NO. 4, according to the plat thereof as recorded in Plat Book 15, at Page 41, of the Public Records of Miami -Dade County, Florida. •••• • • • ••• • • • •• • • • • •• • • •• • . • • • • • • • • • • •• •• • • •• • •••• • • • • • • • •• ••1111 • • •• • • • . • •••• • • •••• • •11•••• • •• . . • • • NORTH SCALE: mi 32.50' fKl • 10110 Certified To: WILLIAM CATE AND DENISE CATE , JERICHO TITLE SERVICES, INC., ATTORNEYS' TITLE INSURANCE FUND, INC., ABN AMRO MORTGAGE GROUP,.INC., ITS SUCCESSORS AND /OR ASSIGNS. tj *avow 0 VIED 411.5 d w r T c;j7.0 AiSIW 18.00' GRASS PWR 115.00' (M) A t1 • Panel Number: 0093 - Suffix: J - • Data of Firm Index: 3/2/94 Flood Zone: X Date of Completion: 05/15/03 Property Address: 490 N.W. 102 STREET MIAMI , FL 33138 Survey: M15830 AVENUE (MeVA.LP.NOFPAY) - 6.50' lbG6011AY 3 710 ' 115.00' (M) A.SP.JI BEIYE GE1VSSAL NOTE& ��• lV;;.. • 11.11.• Iti y :rt'IlF :t:'!' .b + 9r. 4 1: . : �A d + ' . : < :r 0- .. y ' :i •. •'. : ' y .1. n n '1 . ?'. b t N • . a% 14 • • : y NN: tea art • ,.g ••11r. .•::e.• 11. �„y •:.. '; • .i • •g.0- • •)I, :. L z. . tV A O C NO. S 1 ATE OF • t ` Ft • 1111 y � • MIGUEL ESPINOSA LAND SURVEYING, INC; 6494 S.W. 24 STREET MIAMI, FLORIDA 33155 PHONE: (305) 740-3319 LB # 6463 1 HEREBY CFRTIFV T THIS :. , ' Y SURVEY IS AVM AND CORReCT REPRESENTATIOI1 • F A SUR ARED UNDER MY N. „••• i RIDA • • • • • • • •••• • • •• ••• .••• • • 1) LEGAL DESCRIPTION PROVIDED BY OTHERS. 2) THE LANDS SHOWN HEREON WERE NOT ABSTRACTED FOR EASEMENT OR OTHER RECORDED ENCUMBERANCES NOT SHOWN ON THE PLAT. 3) UNDERGROUND PORTIONS OF FOOTINGS, FOUNDATIONS OR OTHER IMPROVEMENTS WERE NOT LOCATED. 4) ONLY VISIBLE ENCROACHMENTS LOCATED. 5) WALL TIES ARE TO THE FACE OF THE WALL. 6) BEARINGS REFERENCED TO LINE NOTED AS B.R. I) NO IDENT IFTCATION FOUND ON PROPERTY CORRNERS UNLESS NOTED. 8) NOT VALID UNLESS SEALED WITH THE SIGNING SURVEYORS Eh/BMW SEAL 9) DIMENSIONS SHOW ARE PLAT AND MEASURED UNL1 S Oj14ERVY'1 SOWN. 10) ELEVATIONS IF SHOWN ARE BASED , • N NA•V.D. 49291UNI..ESS OTHERWISE NOTED. 1 • • • 11) THIS IS A 10 YSUR � `ix� OTHERWISP • • • •• • • • i b0- Tits FIRM • •. • • • • • .• • • •••• •.1.:• 1•.. .Ot• IMO y r. ...dm • • • • THIS SURVEY IS INTENDED FOR MORTGAGE OR REFINANCE PURPOSE ONLY, EXCLUSIVELY FOR THIS USE BY THOSE TO WHOM IT IS CERTIFIED. THIS SURVEY IS NOT TO BE USED FOR CONSTRUCTION, PERMITI NO. DESIGN OR ANY OTHER USE WITHOUT WRITTEN CONSENT OF MIGUEL ESPINOSA. • • • • • •• • • .... • 1 y .f i w> . • �' •••I.; • 4 F� • t • • \ -j LA , : • • •0 4 .. -.-• � c • 0 , , , , • .� • • "� • • i,,}/ • .• •••• • • • • • • •• • • • ••• • • • • • •• • • • • • 0� 2, 5 gi0 •• • • • • • • • • • • • •• •• • • •••• • • • •• • • • • • • •••• • • • • • • •• • • • • • ••• • •• • • • •• • •••• • • •••• • • • • • • • • • • • • • • •• • • • • • • ••• • • • • BUILDING CODE COMPLIANCE OFFICE (BCCO) PRODUCT CONTROL DIVISION NOTICE OF ACCEPTANCE (NOA) Arrow Group Industries, Inc. 1101 N. 4 Street Breese, IL 62230 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by Miami -Dade County Product Control Division and accepted by the Board of Rules and Appeals (BORA) to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Division that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the I1'igh Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Cold Formed Steel Utility Sheds APJSOVAL DOCUMENT: Drawing No. Si, S2 and S3, titled "6' x 5', 8' x 6', 8' x 8' & 10' x 8' Utility Sheds ", • sheets•S t throuuh dated 08/01/2007, prepared by McGinnis & Associates Consulting Engineers, Inc., signed • ankJ gd, by Daniel ;V. McGinnis, P E., bearing the Miami Dade County Product Control Revision stamp with the • Notice of Acceptapce:number and expiration date by the Miami -Dade County Product Control Division. • • 1VMIS t iI,LE IMIIXet' Large and Small Missile Impact L $ELING::Estill emit shall bear a permanent label with the manufacturer's name or logo, city, state and the foll.BRant stategRht'' Miami -Dade County Product Control Approved ", unless otherwise noted herein. • • RE I SIEWAL o iliii shall be considered after a renewal application has been filed and there has been no • • change in the apps ahle building code negatively affecting the performance of this product • • TkitiMikATIplytfjchis NOA will occur after the expiration date or if there has been a revision or change in the =M a% use, and/or Inanufacture of the product or process. Misuse of this NOA as an endorsement of any producer; for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises & renews NOA # 06- 0505.07 and consists of this page 1, evidence submitted pages E -1, E -2 & E-3 as well as approval document mentioned above. The submitted documentation was reviewed by Helpny A. Makar, P.E. M.S. MIAMI -DADE COUNTY, FLORIDA METRO -DADE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 MIAMI, FLORIDA 33130 -1563 (305) 375 -2901 FAX (305) 375 -2908 www.miamidade.aov NOA No. 07-0214.15 Expiration Date: 08/24/2012 0,43`Zo07 Approval Date: 09/13/2007 Page 1 Arrow Group Industries, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 1. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL # 98- 0113.03 A. DRAWINGS 1. Drawing No. 51, S2, & S3, total 3 sheets, prepared by R. T. Wharton, P.E., titled " 6' x 5', 8' x 6', 8' x 8', & 10' x 8' Utility Sheds", dated December 12, 1997, last revision #1 dated July 13 (sheets S1 & S3) and July 14 (sheet S2), 1998, signed and sealed by R. T. Wharton, P.E. B. TESTS 1. Test report on Large Missile Impact Test and Cyclic Wind Pressure Test of "Utility Shed Doors", prepared by Hurricane Engineering & Testing, Inc., Report No. HETI- 97-693, dated 11/18/97, signed and sealed by Hector M. Medina, P.E. 2. Test report on Uniform Static Air Pressure Test of "Utility Shed Doors", prepared by Hurricane Engineering & Testing, Inc., Report No. HETI 97 -692, dated 11/18/97, signed and sealed by Hector M. Medina, P.E. 3. Test report on Large Missile Impact Test and Cyclic Wind Pressure Test of "Utility Shed Panels", prepared by Hurricane Engineering & Testing, Inc., Report No. HETI- 97-691, dated 11/17/97, signed and sealed by Hector M. Medina, P.E. 4. Test report on Uniform Static Air Pressure Test of "Utility Shed Panels'; prepared by Hurricane Engineering & Testing, Inc., Report No. HETI -97 -690, dated 11/17/97, signed and sealed by Hector M. Medina, P.E. C. CALCULATIONS 1. Calculation of " 6' x 5', 8' x 6', 8' x 8', & 10' x 8' Utility Buildings" and anchor • • • • • • • calculations dated 12/26/97, pages 1 to 39 of 39, prepared by Van Dam Engineering, . . •••• s and sealed by R. T. Wharton, P.E. • 2. talculation of " 6' x 5', 8' x 6', 8' x 8', & 10' x 8' Utility Buildings" and anchor • • • • • ; Fjc,ations dated 07 /14/98, pages 1 to 10 of 10, prepared by Van Dam Engineering, • • • • cigrae+d and sealed by R. T. Wharton, P.E. • • • •H.. MATERIAL CERTIFICATIONS • • • • • • • 1. • MR • Certified Test Report issued by National Steel Corporation, with chemical c8 "osition and mechanical properties of structural members. • • • • • • • • 2. ; M1 • Certified Test Report issued by Bethlehem Steel Corporation, with chemical • • • • • • • cbmjlosition and mechanical properties of cold formed panel, dated 07/09/98. • ••••• 3. Tensile Test Report No. HETI- 97 -T64, prepared by Hurricane Engineering & Testing, Inc., dated 12/29/97, signed and sealed by Hector M. Medina, P.E. 4. Tensile Test Report No. HETI- 97 -T65, prepared by Hurricane Engineering & Testing, Inc., dated 12129/97, signed and sealed by Hector M. Medina, P.E. 2. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL # 01- 0430.04 A. DRAWINGS 1. None. f )1. fle/fe helm' A. Maker, P.E., M.S. Product Control Examiner NOA No. 07-0214.15 Expiration Date: 08/24/2012 Approval Date: 09/13/2007 E -1 • • • • • Arrow Grout) Industries, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED B. TESTS 1. None. C. CALCULATIONS 1. None. D. MATERIAL CERTIFICATIONS 1. None. 3. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL # 02. 0401.03 A. DRAWINGS See NOA 01-0430.04 B. TESTS See NOA 01- 0430.04 C. CALCULATIONS See NOA 01- 0430.04 D. MATERIAL CERTIFICATIONS See NOA 01- 0430.04 E. STATEMENTS See NOA 01- 0430.04 ... • • • r ' • OIWL: . . See NOA 01-0430.04 . : 4.• • . E\ N NCE SUBMITTED UNDER PREVIOUS APPROVAL #06- 0505.07 ' A. • DRAWINGS • '•�•.: 'gPIie' . • B.. TESTS.. . • • • • one • 4E: • . CALCULATIONS 1. None. D. QUALITY ASSURANCE 1. By Miami Dade County Building Code Compliance Office. E. MATERIAL CERTIFICATIONS 1. None. E.2 i /r• C � /e A. Makar, , P.E., M.S. Product Control Examiner NOA No. 07- 0214.15 Expiration Date: 08/2412012 Approval Date: 09/13/2007 • • Arrow Group Industries, Inc. 5. NEW EVIDENCE SUBMITTED A. DRAWINGS 1. Drawing No. Sl, S2 and S3, titled "6' x 5', 8' x 6', 8' x 8' & 10' x 8' Utility Sheds ", sheets S1 through S3, dated 08/01/2007, prepared by McGinnis & Associates Consulting Engineers, Inc., signed and sealed by Daniel W. McGinnis, P.E. D. QUALITY ASSURANCE 1. By Miami - Dade County Building Code Compliance Office. E. MATERIAL CERTIFICATIONS 2. None. .... • • • • •.•• • .. •. • • • • • • • • • • • • • •. •• •. • • • • • • •. • • .. • •••• • • • • • • •• • .•• • .. • • • • • ••• • • . •. • • • •••• • • • • NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED E -3 A. Makar, P.E., M.S. Product Control Examiner NOA No. 07- 0214.15 Expiration Date: 08/24/2012 Approval Date: 09/13/2007 • • ••• • • • ••• •• •• • • • • • •• •• • • • • • • • • • • • • • • • • • • • ••• • • • • • • • • • • • • • • • • • • • ••• • • • • • • ••• • • •• • • •• • • • • • • • • •• • • • • •• • • • •• • • • • • FRONT ELEVATION SIDE ELEVATION ROOF PLAN au as act 8' x 8' BUILDING act FRONT E SIDE FlFVATION ROOF PLAN au au an ,0' x 8' RU1DING • • • • • • • • : co • FRGNT ELEVATION SIDE ELEVATION ROOF PUN 6' x 5' BUILDING acs FROM ELEVATION SIDE ELEVATION ROY ___K88 ant acs au 8'x6'RI8D21G au • • • • ••• • • • • • • • • • • • • ••• • • • •• • • s REAR ELEVATION •4t EFILLUDIAEON Ei? r ••� D • 4- 1 • • • eb yxy • • ▪ • • FOUNDATION PLAN an FOUNDATION PLAN act REAR ELEVATION FO11Nm1U0N PLAN an 21 • w•s NM N. 7 AMR mmr DESIGN CRITERIA: THE DESIGN SHOWN ON THESE DRAWINGS MEET THE REQUIREMENTS OF THE 2004 FLORIDA BUILDING CODE. 088M -10601 Y. DEAD LOAD: AS CALCULATED PER MEMBER LIVE LOAD: 15 PSF WIND LOADS; BASIC WIND SPEED: 75 MPH WIND LOAD IMPORTANCE FACTOR: h1 = 1.0 WIND EXPOSURE: C NOTE: PER SECTION 1609.1.4 STORAGE SHEDS THAT ARE NOT DESIGNED FOR HUMAN HABITATION AND THAT HAVE A FLOOR AREA OF 720 S.F. OR LESS ARE NOT REQUIRED TO COMPLY WITH THE MANDATORY WINDBORNE DEBRIS IMPACT STANDARDS OF THE 2004 FLORIDA BUILDING CODE. MATERIAL SPECIFICATIONS: PANELS: ASTM A625 -76, Fy=50 KSI CHANNELS & OTHER MEMBERS: ASTM A527 -80. Fy=55 KSI BOLTS & SCREWS: ASTM A1018, Fy=30 KSI ANCHOR BOLTS: ASTM A307, Fy=33KSI REINFORCING STEEL: ASTM A615 -40, GRADE 40 WIRE MESH: ASTM A -185 CONCRETE 2,500 PSI COMPRESSIVE STRENGTH 0 28 DAYS ASSUMED ALLOWABLE SOIL BEARING PRESSURE: 1.000 PSF 0 A DEPTH OF 1' -0' MCGINNIS & ASSOCIATES COMMUNE' INMENIS, Ds 1110 •OMNIN DINE SL LOPS, mom $3131 314 -4 1-OND 12909 b ODc • 1741148 PLANS & ELEVATIONS •oae, 6'x5'. 8'x6', 8'x8' & 10'x8' UTILITY SHEDS NONE or.w JMH ago 8/1/06 ARROW GROUP INDUSTRIES ' 1101 N. 4TH STREET BREESE, IL 62230 (618) 526 -4546 S 1 • • ••• • • • .. •. • • • .• •• • • • • • • • • • • • • • •.• • • • • • • • • • • • ••• • • • • ••• • • • • •. • • ••• • ••• • • • • • • • • •• • • • • •• • • •• • • • • 0 Viff I ' 1 0.023 T 1/8" 1 DOOR ELEVATION N.TS 1011/2" SCREWS (18) EA. PANEL 11x7 16" � �MACH MACHINE (2) EA * fiMHEI. 10x ScR1.w5 & OF PANEL II ur .023" L CHANNEL N.T.S. w PANEL WIDTH VARIES J. TYPICAL PANEL FASTENER ELEVATION DOOR SIGN 0.018' 0.030' 2 CHANNEL HINGE TYP. 2 PLACES • • • • • • • 4 1 9 19/32" s 8• REF t 1/4' ••A • 0 • . 1.-44, 04 .• • ! L 1� p1 • • 28 3/4" TYPICAL WALL PANEL NOTE: PANEL WIDTH YAlS6 SECTION ALTS FIN. GR. SECTION N TS. • • • .• • 4x1 1/2"x0.080" CHANNEL r 0.023" JANE fi NIMES (2 TOTAL) •/ (8) /18'0 FIAT HD. NpCHNE SCREWS & NUTS 0 x 8' ANCHOR BOLTS 0 24 "o.e. AT SIDE & BACK WALLS. & 0 12 "me. MAX. 0 FRONT SWILL ALTERNATE ANCHOR: NIUI on( BOLT 1 3 /8'0x5" CONCRETE ANCHOR 0 24 "o.e. *12 e METRO DADE COUNTY 14 CONT. TOP &BOT. 8x8 -10/10 WWM ALT. - 13 BARS 0 18"0.e. EA. SWAY • • • • • • • ••• • • •• SECTION MTS. WALL OR ROOF PANELS • L 1 7/8' X 1 1/4" 0.0•" 2 ROWS 110 x 7/16" MACHINE SCANS • 8 "o. . WALL OR ROOF CHANNELS ix4x.023' SECTION ALTS SECTION N.TS 10 (1 SECTION N.T.S. SCREWS ( L (2) $10x1/2" 3/8 "0 ANCHOR 601.TS (SEE FND. PLAN & )) SECTIONS F R S ): 3/8 "0 HUT CONCRETE ANg2ORS SECTION Lt xix0.028" BRACE O f t MACHINE SCREWS & NUTS WALL PANEL NUT ROOF BEAMS FLOOR FRAME (0.0287 SPACER I10 MACHINE SCREWS BOLT VERRCLE ANGLE TO GABLE PANEL RETURN axLPb�8 Pb1 B aBCado au 7� al McGINNIS & ASSOCIATES Mara avvIE581. INC. a atO 103tIVac OWE IL 88 83131 314- 4884480 12909 CUT INSIDE FLANGE AT CORNER 110 MADINE SCREW S WALL CHANNEL CORNER CONNECTION SECTION N.T.S. 110 MACHINE SCREWS 4 TOTAL) L7 /8x1 1/8'x0.028" 110 x 1/2' SCREW L 7/8x1 E /4x0.028' 1' SECTION N.T.S. S 1101 it. war um BOLT VERRCLE *AVM TO GABLE PANEL RETURN GABLE .018" THICK 10601 SECTIONS & DETAILS z s 0011116 8 8 & 10' %8' UTILITY SHEDS ARROW GROUP INDUSTRIES 1101 N. 4TH STREET BREESE, IL 62230 (618) 526 -4546 •e8 NONE COM JA sem 8/1/06 ...a1 S2 • • ••• • • • ••• •• •• • • • • • • • • • • • • • • • • • • • • • • • • • • ••• • • • • • • • • • • • • • • • • •• • • • • ••• • • • ••• • • • • • • • • •• • • • • •• • • •• • • • • 2 ° x1" CHANNEL 0.023 THICK WALL PANEL DETAIL N.T.S. FLOOR FRAME (0.0281 810x1/2 SCREW TYP. NEAR SIDE & FAR SIDE 0.016' DOOR SKIN 1/2 CHA NNEL (DOOR JAMB) / Ll w /(4) #10 SCREWS LONG x 0.034 1"x2.701 x0.030" DOOR JAMB TRIM SECTION N.T.S. 8 0 SCREW SECTION N.T.S. • • s • • • • • • • • • • • • • • • • • • ••• • ••• • 2 "x1" CHANNEL :!0i • • • • • SECTION N.T.S. 0.030 ZEE ZEE DOOR TRIM NOT SHOWN FOR CLARITY VOxt /9J'SlcREWS • SIKES AND • 0 TOP:dc BOT. • ••• •• 110x1/2 SCREWS (5) EA. SIDE FLOOR FRAME (.028") SECTION N.T.S. S3 3 L1 1/2 "x2 1/8 "x0.80" • LEFT DOOR 11 1/8 "x2 "x0.30" • RIGHT DOOR 1 "x2.701 x 1.053 "x0.030 DOOR JAMB TRIM 2 "x1 CHANNEL 0.023" THICK SECTION N.TS. 4 1/2 CHANNEL (DOOR JAMB) 810 SCREW L1 1 4'x3"xt 1/2 LONG x 0.034" w/(4) 810 SCREWS 0.030 ZEE ZEE DOOR TRIM NOT SHOWN FOR CA (DOOR JAMB) 4 © •• ' COPE WEB 0.016' DOOR SKN SECTION 3 N.T.S. S3 4 "x1 1/2 CHANNEL #10 SCREW SECTION N.T.S. 4x1 ° x0.028 ° CHANNEL 2 21 CHANNEL 110 SCREW NOTCH FOR DOOR JAMB COPE WEB AS REQUIRED 1'x2.701 x1,053 x0.030" DOOR JAMB TRIM Lt 1/4 "x3 x1 1/2" LONG x 0.034 w /(4) 810 SCREWS S3 4x1 1/2° x 0.60 CHANNEL no On am Int FLOOR FRAME (.028 SECTIONS & DETAILS FRolniCTREVISED Imo" Zom wintMWRW Atev•aeMfl , —02! 6xolmdau .. -l�i,► ` Untie Magee MEM NONE Me U& Minnie 6'x5. 8'x6'. 8'x8' & 10'x8' JMH UTILITY SHEDS 6 / 1/06 McGINNIS & ASSOCIATES COMM xs oamNEEPs. ac. ARROW GROUP INDUSTRIES tie wssiw x OWE 1101 N. 4TH STREET ^ /� ST. OS • • LO 63131 BREESE. IL 62230 V \ 3 314 12909 (618) 526 -4546 .I RECEIPT PERMIT #: RC-t 0 — G N C DATE: 1, _) e ❑ Contractor Owner ❑ Architect Picked up 2 sets of plans and (other) ?U S l 4-4 1 Address: `I b K OZ �l From the building department on this date in order to have corrections done to plans And /or get County stamps. I understand that the plans need to be brought back to Miami Shores Village Building Department to continue permitting process. Acknowledged by: PERMIT CLERK INITIAL: RESUBMITTED DATE: tit aa0 1 PERMIT CLERK INITIAL: Miami Shores Viiiage Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 Ado Inspection Number: INSP - 148979 Scheduled Inspection Date: July 27, 2010 Inspector: Rodriguez, Jorge Owner: OR OWNERS, CURRENT OCCUPANT Job Address: 490 NE 102 Street Miami Shores, FL 33138- Project: <NONE> Contractor: HOME OWNER Building Department Comments July 26, 2010 Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 For Inspections please call: (305)762 -4949 Permit Number: RC- 5- 10-940 Permit Type: Residential Construction Inspection Type: Final Work Classification: Shed Phone Number Parcel Number 1132060170550 INSTALL A NE METAL SHED IN BACKYARD 10X8 ARROW GROUP Passed Failed Correction Needed Re- Inspection Fee No Additional Inspections can be scheduled until re- inspection fee is paid. Inspector Comments CREATED AS REINSPECTION FOR INSP- 148710. Missing screws and base anchors. NB Page 9 of 25