Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
361 NE 102 St (6)
PERMIT APPLICATION FOR MIAMI SHORES VILLAGE Date / a / t - Job Addres ' 1 l ( Tax Folio • it 3 ao 0/ 3 Z Legal Description II= I to/ [ , 9.0 t 1 J-c& 3 ? Historically Designated: Yes No Owner/Lessee / Tenant ER I et'elati2 (� / Owner's Address 3 �D ( 4E' I ©r- 9 Y, /k M d W- j eetef Contracting Co. Eli He(NLg 11;4_ COi Qualifier JftcA: C. Pr r2 State # (NCO 0$031 Municipal # Architect/Engineer Bonding Company Mortgagor Address • Permit Type (circle one): BUILDING ELECTRICAL PLUMBING ECHANICAL ' OFING PAVING FENCE SIGN WORK DESCRIPTION , trst -(( C e#erza f-f 4-1:tz too -eGd" / /-efe ree- 7 5 T OA-1 10 t tic% Cf r 7 c 6 c 6274 -4p o2-,i) Square Ft. Estimated Cost (value) 5000° WARNING TO OWNER: YOU MUST RECORD A NOTICE OF COMMENCEMENT AND YOUR FAILURE TO DO SO MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY (IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.) Application is hereby made to obtain a permit to do work and installation as indicated above, and on the attached addendum (if applicable). I certify that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that separate permits are required for ELECTRICAL, PLUMBING, SIGNS, POOLS, ROOFING and MECHANICAL WORK. OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Furthermore, I authorize the above -named contractor to do the work stated. /d "tse -t( Signature of owner and/or Condo President Date r. Notary as to Owner an Condo President Date My Commission Expires: 1<'e cy-4 et ba497 cc Pf�1�_ 6oµ M15SbN -# 16 2001 `!� EX �Dto� lt�- P1tflS 111 ' # FEES: PERMIT d ! O RADON Address / 71 - 50 4"E 3316), 45 S 30 Competency # Ins. Co. Address Address Signature of Contractor or O er- Builder Master Permit # 1 4 a 77 Phone 7.5 7-- 5 r t/ a N. as to Contractx,,ox 'I de RIGGLE My Commission E)ir; 1-c.;, 1-c.;, COMMISSION #'CC 649234 I fill 0 a Q EXPIRES JUL 31, 2001 �f)F fe ATLANTIC BONDING CO., INC. Date Date C.C.F. 4 t vC NOTARY BOND TOTAL DUE /if: " APPROVED: Zoning / Building Electrical Mechanical — 16 — 7 Plumbing Engineering NOTICE OF COMMENCEMENT A RECORDED COPY MUST BE POSTED ON THE JOB SITE AT TIME OF FIRST INSPECTION PERMIT NO. STATE OF FLORIDA: COUNTY OF DADE: THE UNDERSIGNED hereby gives notice that Improvements will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information Is provided In this Notice of Commencement. 1. Legal description of property and street address: 'i21 M -P - /1JE Gs -2- 2. Description o1 Improvement: 3. Owner(s) name and address: Interest In property: Narhe and address of lee simple titleholder: 4. Contractor's name and address: S. Surety:(Payment bond required by owner from contractor, II any) Name and address: Amount of bond $ 6. Lender's name and address: TAX FOLIO NO. il.,3261k136-60 7. Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 71 3.13(1)(a)7., Florida Statutes. Name and address: 8. In addition 10 himself, Owner designates the following person(s) to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b), Florida Statutes. Name and address: 9. Expiration date of !his Notice of Commencement: (the expiration date Is 1 year from the date of recording unless a iifterent date Is specified) Signature or Owner Print Owners Name En_ccr f --t - 4Pe'V Sworn to and subscribed before me This day of ,Srq. . 19 g Votary Public S Tint Notary's Name '.Ay Commission Exc :res: ice c'f � C :. OIWMI N 0 CC 664497 .TATMAN "A d EXPIRES 6 2001 ARANTIC DOMING CO.; INC. W TNESS my h:'nd and Official Seal. HARVEY RUVIN K Circe' y STATE OF FLORID ADE 1 HEREBY CERTIFY that this is o frue eop of fho original filed in this office on AP day of ' A. D. 19 ourto D.C. Prepared b i .1: c ,_Cr ? L r ./r , 4 &et Address: /78's' /✓L' -4 t/ ,%'/ , ,�., , , G S3/ Z THE BENSON RESIDENCE HVAC LOAD ANALYSIS for •Enc and Connte Benson ;. ............................. ............................... •61: NE •102nd Street Mlami Shores, FI.'33138 RHIVM Residential and Light Commercial HVAC Loads Prepared By: Keith C. Tatman Edd Helms AirConditioning & Electric Inc 17850 N.E. 5th Ave. Miami , Fl. 33162 (305) 653 -2530 09 -10-97 RHVAC - Residential & Light Commercial HVAC Loads Program Carrier South Florida North Miami Beach, FL 33162 -1017 09 -10.97 Elite Software Development, Inc. The Benson Residence Page 2 Project Summary Client: Address: City: Phone: Fax: Design Data Project Name: Reference City: Daily Temperature Range: Latitude: Elevation: Winter. Summer. Check Figures Building Loads Notes Eric and Connie Benson 361 NE 102nd Street Miami Shores, Fl. 33138 (305) 757 -5408 Total Building Supply CFM: 1715 Square feet of room area: 2,100 Total heating required with outside air. Total sensible gain: Total latent gain: Total cooling required with outside air. 40,498 Btuh 37,725 Btuh 8,173 Btuh 45,898 Btuh Company: Representative: Address: City: Phone: Fax: Comment: The Benson Residence Miami, Florida Low 25 Degrees 10 Feet Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb ReLHum. Dry Bulb Difference 40 N/A N/A 70 N/A 95 78 50% 75 53 CFM per square foot: 0.817 Square feet per ton: 467.594 Calculations are based on 7th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. Edd Helms AirConditioning & Electric Inc Keith C. Tatman 17850 N.E. 5th Ave. Miami , Fl. 33162 (305) 653 -2530 (305) 653 -7933 Voice mail , Ext.205 40.498 MBH 82 % 18 % 3.825 Tons (based on sensible + latent) 4.491 Tons (based on 70% sensible capacity) Wednesday, September 10, 1997 RHVAC - Residential & Light Commercial HVAC Loads Prog Caner South Florida North Warn Beach, FL 33162 -1017 09-10 -97 Elite Software Development, inc The Benson Residence Page 3 Miscellaneous Project Data Project File Name: BENSON -5 System input: Data —System 1— Winter. Summer. • External Overhangs No. Pro Offset 1 1 1 2 2 1 3 3 1 4 4 1 5 5 1 Duct Sizing Inputs Duct Material: Roughness Factor. Pressure Drop: Minimum Velocity: Maximum Velocity: Minimum Height: Maximum Height: Outside Air Data Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb ReLHum. Dry Bulb Difference 40 N/A N/A 95 78 50% Runouts Flexible Duct 0.010000 0.1000 In. wg /100 Ft. 450.0 Ft./Minute 750.0 Ft./Minute 0 Inches 10 Inches Winter Infiltration: 1.200 AC/Hr Volume of Conditioned Space: X 18900 Cu.Ft. 22,680 Cu.Ft./Hr X 0.0167 378 CFM 0 CFM Total Building Infiltration: Total Building Ventilation: — System 1--- Infiltration & Ventilation Sensible Gain Multiplier. Infiltration & Ventilation Latent Gain Multiplier. Infiltration & Ventilation Sensible Loss Multiplier. 70 75 N/A 53 No. Pro Offset 6 6 1 7 7 1 8 8 1 9 9 1 10 10 1 Main Trunk Flexible Duct 0.010000 0.1000 In. wg /100 Ft. 650.0 Ft./Minute 900.0 Ft./Minute 0 Inches 0 Inches Summer 0.600 AC /Hr X 18900 Cu.Ft. 11,340 Cu.Ft./Hr X 0.0167 189 CFM 0 CFM ..................... 22.00 = (1.10 X 20.00 Summer Temp. Difference) 35.94 = (0.68 X 52.86 Grains Difference) 33.00 = (1.10 X 30.00 Winter Temp. Difference) Wednesday, September 10. 1997 RHVAC - Residential & Light Commercial HVAC Loads Prog Canter South Florida North Miami Beach, FL 33162 -1017 09 .. Elite Software Development, Inc. The Benson Residence Page 4 -10-97 Total uilding Summary. Loads Component Area Sen. Lat. Description Quan Loss Gain Sen. Gain Total Gain 1C Window Clear Glass Metal Frame 190 6,584 0 10D Door Wood Solid Core 42 580 0 14B Wall 8" or 12" Block + R -5 1,568 6,774 0 16C Ceiling R -11 Insulation 2,100 5,544 0 22A Slab on Grade No Edge Insulation 200 4,860 0 12,850 534 4,583 8,870 0 12,850 534 4,583 8,870 0 Subtotals for structure: 4,100 24,342 0 Active People: 6 0 1,380 Inactive People: 0 0 0 Appliances: 0 0 0 Lighting: 0 0 Ductwork: 0 3,682 0 Infiltration: Winter CFM: 378.0, Summer CFM: 189.0 232 12,474 6,793 Ventilation: Winter CFM: 0.0, Summer CFM: 0.0 0 0 0 26,837 1,800 0 1,500 0 3,430 4,158 0 26,837 3,180 0 1,500 3,430 10,951 0 Sensible Gain Total: Temperature Swing Multiplier. 37,725 X1.00 Building Load Totals: 40,498 8,173 37,725 45,898 Check Figures Total Building Supply CFM: 1715 CFM per square foot: 0.817 Square feet of room area: 2,100 Square feet per ton: 467.594 Building Loads Total heating required with outside air. 40,498 Btuh 40.498 MBH Total sensible gain: 37,725 Btuh 82 '% Total latent gain: 8,173 Btuh 18 Total cooling required with outside air. 45,898 Btuh 3.825 Tons (based on sensible + latent) 4.491 Tons (based on 70% sensible capacity) Notes Calculations are based on 7th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. Wednesday, September 10, 1997 • • • .. ... , . • • , . .. • :11..1.4 ,-144.4,.....).•.••• RHVAC Resldentlal & Light Commercial HVAC Loads Carver South Flbnda Noifh MiamiBeach, FL : 33162=101 09 4S. 9 7 : : : Software Develo htG e Benson Residence P age 5 System # 1 Summery Loads Component Description 1C Window Clear Glass Metal Frame 10D Door Wood Solid Core 14B Wall 8" or 12" Block + R -5 16C Ceiling R -11 Insulation 22A Slab on Grade No Edge Insulation Subtotals for structure: Active People: Inactive People: Appliances: Lighting: Ductwork: Infiltration: Winter CFM: 378.0, Summer CFM: 189.0 Ventilation: Winter CFM: 0.0, Summer CFM: 0.0 Sensible Gain Total: Temperature Swing Multiplier. System Load Totals: Supply CFM: 1,715 Square feet of mom area: 2,100 Total heating required with outside air. 40,498 Btuh Total sensible gain: 37,725 Btuh Total latent gain: 8,173 Btuh Total cooling required with outside air. 45,898 Btuh Notes Calculations are based on 7th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. Area Sen. Lat. Sen. Total Quan Loss Gain Gain Gain 190 6,584 0 12,850 12,850 42 580 0 534 534 1,568 6,774 0 4,583 4,583 2,100 5,544 0 8,870 8,870 200 4,860 0 0 0 4,100 24,342 0 26,837 26,837 6 0 1,380 1,800 3,180 0 0 0 0 0 0 0 0 1,500 1,500 0 0 0 0 3,682 0 3,430 3,430 232 12,474 6,793 4,158 10,951 0 0 0 0 0 37,725 X1.00 40,498 8,173 37,725 45,898 CFM per square foot: 0.817 Square feet per ton: 467.594 40.498 MBH 82 % 18 % 3.825 Tons (based on sensible + latent) 4.491 Tons (based on 70% sensible capacity) Wednesday, September 10, 1997 BUILDING PL L UM NG ❑ PERMIT ROOFING ❑ LI Owner of ,�; Building I L ■ , t '.� +eLf Legal Lot Description CONTRACTOR OR BUILDER MIAMI SHORES VILLAGE, FLORIDA DATE it 19 Architect Contractor ,07:S.5. �i. or Builder '��� N? 7812 Work to be performed under this Permit 11 B Contractor's License No. .1, )13a/ . ' 71 Subdi- vision Address of , �„ Value of ....r ' Building / < 41 Project $ I Amount of Pe $ 7 This permit is granted to the contractor or builder named above to construct the building or to install the equipment or device described in the applica- tion herefor in strict compliance with all ordinances pertaining thereto and with the understanding that the work will be performed in compliance with any plans, drawings, statements or specifications that may have been submitted to and approved by the proper municipal authorities. This Permit may be revoked, at any time if the work is not done in compliance with such ordinances or if the plans are changed without authorization. A further condition upon which this permit is granted is the understanding that the contractor or builder named above assumes the responsibility for a thorough knowledge of the ordinances and regulations pertaining to the work covered hereby whether shown on the plans or drawings or in the statements or specifications and that he assumes respon- sibility for work done by his agents, servants or employees. /� / , _ _ I Signed. ., ` ° _ 4 c J 4 if l INSPECTOR In consideration of the issuance to me of this permit I agree to perform the work cov red hereunder inlompliance with a ordincmce and regulations pertaining thereto and in strict conformity with the plans, drcrwings, statements or specifications submitted to the proper authorities o Miami Shores Village. In ac. cepting this permit I assume responsibility for all work done by either, myself, my agent, servcmt or employee. 3 AUTHORITY ,cent MIAMI SHORES VILLAGE BUILDING INSPECTION DEPARTMENT APPLICATION FOR BUILDING PERMIT 1 Application is hereby made for the approval of the detailed statement of the plans and specifications herewith submitted for the build- ing or other structure herein described. This application is made in compliance and conformity with the Building Ordinance of Miami Shores Village, Florida, and all provisions of the Laws of the State of Florida, all ordinances of Miami Shores Village and all rules and regulations of the Building Division of Miami Shores Village shall be complied with, whether herein specified or not. A copy of approved plans and specifications must be kept at building during progress of the work. s ue _ Date , 19__4 Owner's Name and Address __ No Street /146 Registered Architect and /or Engineer Name and address of licensed contractor �*�� � - mss. / / fly 604 7d Location and legal description of lot to be built on: Lot Block Subdivision Pp Street and Number where work is to be done 2.6_/__ ___ _ G_j_______l_Q__Y_ State work to be done and purpose of building (by floors)__ /— Z_! 0° —c., e°`•■• and for no other purpose. New Building Remodeling Addition Repairs No. of Stories To be constructed of Kind of foundation Roof Covering Estimated Total cost of improvements $ _Amount of Permit $ 1 a Zone cubage required Flan Cubage Distance to next nearest building __________Size of Building Lot Maximum live load to be borne by each floor _ _____________________�______ - I hereby submit all the plans and specifications for said building. All notices with reference to the building and its construction may be sent to The undersigned applicant for this building permit does hereby certify that he understands and accepts his obligations as an employer of labor under the Florida Workmen's Compensation Act, being Section 5966, Compiled General Laws of Florida, Permanent Supplement, and has complied with the provisions thereof, and will require similar compliance from all contractors or sub - contractors employed by him in the work to be performed under this permit; and will post or cause to be posted for inspection on the site of the work such public notice or notices as are required by the Act. The undersigned agrees to employ only such subcontractors, on work to be performed under this permit, as are licensed by Miami Shores Village. Remarks (Signed) __ STATE OF FLORIDA, COUNTY OF DADE. j ss Before me, the undersigned authority, a notary public, duly authorized to administer oaths and take acknowledgments, personally ap- peared ------- ----------- -------- _-------- — —__ -- _ to me well known, and who, being by me first duly sworn, upon oath deposes and says that he is the of the above described construction, that he has carefully read the foregoing application, and that he did sign the same, and that all facts therein by him stated are true. 1> Permit No 1___ / _ Date__ .� — �: _� Read, Sworn to and Subscribed before me. Disapproved Date p Notary Public, State of Florida ( Signed) �l� Buildi nspector / My Commission Expires PLANNING BOARD DATE Chairman Member Member Member Member Member Council Approved Date Disapproved Date NOTE: A charge of $1.00 will be made for making corrections or changes to this application after approval has been obtained from the Planning Board. A re- inspection fee of $1.00 will be charged when such re- inspection is made necessary by improper notice for inspection or faulty materials and /or workmanship.