RF-10-1239FLAT ROOF
Passedi:
Inspector Comments
(r..,,
Failed
Correction
Needed
Re- Inspection
Fee
No Additional Inspections can be scheduled
re- inspection fee is paid.
until
Inspection Date: August 30, 2010
Inspector: Bruhn, Norman
Owner: KENYON NAFIS, SANCLER ANDRADE
Job Address: 13 NE 108 Street
Project: <NONE>
Contractor: DADE ROOFING CORPORATION
Building Department Comments
August 31, 2010
Miami Shores, FL 33138-
Inspection Worksheet
Miami Shores Village
10050 N.E. 2nd Avenue Miami Shores, FL
Phone: (305)795 -2204 Fax: (305)756 -8972
Inspection Number: INSP - 148030 Permit Number: RF' -7 -10 -1239 I
For Inspections please call: (305)762 -4949
Permit Type: Roof
Inspection Type: Final Roof
Work Classification: Flat
Phone Number ()-
Parcel Number 1121360110420
Phone: (305)835 -7000
Page 1 of 1
1
501% -.
BUILDING Permit No22-P( °'
PERMIT APPLICATION Master Permit No.
FBC 20
Permit Type: BUILDING //// ff``
OWNER Name (Fee Simple Titleholder): / V/ /XA r� is 3 5 761
Address: / 3 .r/A" /0t •
City: /0/. State: Zip: a3/ 6 /
Tenant/Lessee Name: Phone#:
Email:
JOB ADDRESS: /3 NE / ' ..i7
City: Miami Shores County: Miami Dade Zip:
Folio/Parcel#: // c /- C-• ®`/ -
Is the Building Historically Designated: Yes
Miami Shores Village
Building Department
10050 N.E.2nd Avenue, Miami Shores, Florida 33138
Tel: (305) 795.2204 Fax: (305) 756.8972
INSPECTION'S PHONE NUMBER (305) 762.4949
CONTRACTOR Company Name: e 9Fiet/ J C7 Phone#: �D�. �v 0
Address: 36 5 ( f %p c
City: iW I AM r State: PL- Zip: 33/4
Qualifier Name: AR ie Prr,4■4rr®corl G Phone#:
State Certification or Registration #: Certificate of Competency #:
Contact Phone# :.� 86P 7€ *a ' Email Address: C 6" rcby roc � L /4S/i/1 • keg
DESIGNER Architect/Engineer: •J Phone#:
Value of Work for this Permit: $ 50d e
Type of Work: °Address OAI -_ . a; on °New ORepair/Replace _pW = GA-�
COLOR THROUGH ROOF TILE IS REQUIRED acknowledged by:
NO Flood Zone:
Square/Linear Footage of Work:
rr"olITVE9
M ; g
°Demolition
Submittal Fee $ Permit Fee $ . -
Od
CCF $ 3 CO /CC $
OA
Scanning Fee $ e ' J Radon Fee $ ' ` DBPR $ Bond $
Notary $ Training/Education Fee $ Technology Fee $ 4 •XJ
Double Fee $ Structural Review $
TOTAL FEE NOW DUE $ an-cr
•
Bonding Company's Name (if applicable)
Bonding Company's Address
City State Zip
Mortgage Lender's Name (if applicable)
Mortgage Lender's Address
City State Zip
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has
commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating
construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS,
WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC
OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all
applicable laws regulating construction and zoning.
"WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF
COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR
IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN
FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE
RECORDING YOUR NOTICE OF COMMENCEMENT."
Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must
promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person
whose properly is subject to achment. Also, a certified copy of the recorded notice of commencement must be posted at the job site
for the first inspection wh occurs seven (7) days after the building permit is issued In the absence of such posted notice, the
inspection will not be appr s' and a reinspection fee will be charged
Signature., Signature
Owner r Agent �-
The forego g instrument was acknowledged before me this r Y The foregoing instrument was acknowl
day of C2( 20/0, by / 1 , day of j &tZ . 20/0 , by 4.
who is personally known to me or who has produced who is personally known to me or who has produced
As identification and who did take an oath as identification and who did take an oath.
SONNIA SILSBY
ES: October 21, 2011
NOTARY PUB
Sign:
My Commission Expires:
(Revised rrmorm)(Rev r06/1O/2009XReised3n5/09Xrev6/4/10)
before me this o?
ar o�� ,
SONNIA SILSBY
** *,t*** *** * *****+r, ***r*** *** *** ** *** sir ** era*************************, r******** tr, tur **** ** * **** **** *arr**** ** * ** **
APPROVED BY /' /y ( Plans Examiner Zoning
Structural Review Clerk
V
A RECORDED COPY MIIST BE POSTED ON THE JOB SITE AT TIME OF FIRST INSPECTION
TAX FOLIO NO.
PERMIT NO.
HEREBY
&VIM Remit,
STATE OF FLORIDA
COUNTY OF DADE
THE UNDERSIGNED hereby gives notice that improvements will be
certain real property, and in accordance with Chapter 713, Florida Statutes,
the following information is provided in this Notice of Commencement:
1. Legal description of property and street address:
2. Description of improvement
3. Owner (s) name and address: ke ye
/04sW ft/ r A lifr• 104 Maw; .33/3y
Interest in property: CAlm:=7"
Name and address of fee simple titleholder:
4. Contractor's name and address: Dade Roofing Corp.
3654 SW 23 Terr Miami, Fl. 33145 A
5. Surety: (Payment bond required by owner from contractor, if any)
Name and address:
Amount of bond: $
6. Lender's name and address:
NOTICE OF
• COMMENCEMENT
N A
N A
Re-kooP"
7. Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 713.13
(1) (a) 7., Florida Statutes: N /A
Name and address:
81n addition to himself, Owner designates the following person (s) to receive a copy of the Lienor's Notice as provided in Section 713. 13 (1)
(b) 7., Florida Statutes: N/ A
Name and address:
9, Expiration date of this Notice of
• IV, V. .1
A
Signature of Owner
Print Owner's Name ittApilt
Sworn to and subscribed before me this / 7 day ofja_Le , Mit!'
Notary Public
Print Notary's N
My Commission
1111111111111111111111111111.0111111101
CFN 2010R0549960
OR Bk 27387 Ps 1851; (1 9 )
RECORDED 08/13/2010 1343:53
HARVEY RUVIN, CLERK OF COURT
MIAMI-DADE COUHTYt FLORIDA
LAST PAGE
,'3d S'/ 411,2Att'..1071,,e& py... 33/6/
t (the expiration date is lyear from the date of recording unless a different date is specified) •
Prepared by: F. Zamora
Address: 1090 E 28 St
Hialeah, FL.33013
Form I%
a•d'ra- 'c =r' ®Ja ; we s ^9d'e °rpc z• y° "d` 9 AdP
SECTION 1524
VELOCrilt IIIIRRICANE ZONES 11EIQUIRE10» OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS
1524.1 As it pertains to this section, it is the responsibility of the roofing contractor to provide the owner with the
required roofing peon it, and to explain to the owner the content of this section.. The provisions of Chapter 15 of
the Florkke Buildise Cam, Big govern the minimum requirements and standards of the industry for roofing
iystem installations. Additionally, the following items should be addressed as part of the agreement between the
owner and the contractor. The owner's initial in the adjacent box indicates that the item has been explained
I. Aesthetics-Workmanship: The wcarkutanship provisions of Chapter 15 (High Velocity Hurricane
Vie) are for the purpose of providing that the roofing system meets the viand rye and water intrusion
performance standards_ Aesthetics (appearance) issues are not a consideration with respect to worlonanship
srovisions. Aesthetic issues such as color or architectural appearance, that are not part of a zoning code, should
3e • as part of the agreement between the owner and the contractor.
2. Renailing Wood Decks: When replacing roofing, the existing wood roof deck may have to be
.mailed in accordance with the current provisions of Chapter 16 (High Velocity Hurricane Zones) of* Florida
3wlding Code. (The roof deck is usually concealed prior to removing the existing roof yam). • • • • •
•
3. Co , n Roofs: Common roofs are those which have no visible delineation,
• between neighboring •
snits (Le. townhouses, condominiums, etc.). In buildings with common roofs, the roofin add/ •
g�aontractor c
ewner should notify the occupants of adjacent units of roof mg work to be perform, ` "' •
1 4,•
4. Exposed Ceilings: Exposed, open beam ceilings are where the underside
from below. The owner may wish to maintain the architectural opportune;
►enetratious of the underside of the decking may not be acceptable. The Florida Buil
►ption of maintaining this appearance.
5. Pending Water The current roof system and/or deck of the building
ause water to pond (accumulate) in low-lying areas of the root Ponding can be an indication of structural
and may require the review of a professional structural engineer. Ponding may shorten the life
xpectancy and performance of the new roofing system. Ponding conditions may not be evident until the original
oofmg system is removed. Ponding conditions ehhould be corrected.
6. Overflow scuppers (wall outlets): It :is required that rainwater flow off so that the roof is not
oaded front a build up of water. Perimeter /urge walls or other roof extensions may block this discharge if
verfow scuppers (wall outlets) are not provided. It may be nor to install overflow scuppers in accordance
rith e Florida Building Code, Plumbing.
11
7. Ventilation: Most roof structures should have some ability to vent natural airflow through the interior
e structural assembly (the building itself) The existing amount of attic ventilation shall not be reduced. It
nay be beneficial to consider additional ven e:' , Much can result in extending the service life of the roof.
Sic/ //c /•20and%20Seitings/ 1: A[11.6ms9/2721Q07 S :46:06 AM AP P R o v E D
.1 .1
vvner's/Agenfs Signature:
ontr- actor's Signature:
:operty Address:
i
Date:
1 Permit Number:
$ " gli ®sc -
il.�i - ll
BLDG DEPT
ZONING DEPT
SUBJECT CO CCMPUANCE WITI1 ALL FEDERAL
BY DAIE
•
• •
•
•
•
ROOF ASSEMBUES AND ROOFTOP STRUCTURES
El New Roof
Low Slope
El Asphaltic
Shingles
Florida Building Code Edition 2007
High-Velocity Hurricane Zone Uniform Permit Application Form.
Section A (General Information)
Master Permit No. Roof Permit No.
Contractor's Name Dade Roofing Corp
Job Address 13 N.E. 108 St
ROOF CATEGORY
0 Mechanically Fastened Tile
El Metal PaneUShingles
O Prescriptive BUR-RAS 150
ROOF TYPE
INFORMATION
Low Slope Roof Area (SF)1 587 1 Steep Sloped Roof Area (s9
Section B (Roof Plan)
0
0 Mortar/Adhesive Set Tile
El Wood Shingles/Shakes
N
GASJ
•
•
• • •
•
• •
• • • •
• •
3 IS
1.5"
ISO
• • • •
• •
• • • •
Reroofing Jj Recovering 0 Repair 0 ininenance ••••
• • • •
ROOF SYSTEM •••• ••••
•
• • • • •
• • •
• •
• • •
• • •
• • •
58' 1
• •
• •
• • •
• • • • • • •
• •
Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow draittl•
include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of
parapets•
No
Parapets
OPEN all
around
15.32 FLORIDA BUILDING CODE — BUILDING
CITY OF PLANTATION
• •
• •
• •
•
•
Section C
High Velocity Hurricane Zone Roofing Permit Application Form
-
"Delivering Excellence Every Day" Section C page (Low Slope Roof Systems)
Fill in the specific roof assembly components. If a component is not required, insert not applicable (n/a) in the text box.
Top Ply:
ROOF SYSTEM MANUFACTURER:
Product Approval (NOA):
(P1) Field:
-49.2
(P2) Perimeters:
(P3) Comers:
Roof Slope:
Support Spacing:
Alternate Deck Type:
Existing Roof:
Fire Barrier:
Vapor Barrier:
Anchor Sheet:
EMI
0.25
-82.6
N/A
psf
GAF Glass Base #75
Base Sheet(s) & No. of Ply(s):
07- 1219.09
Wind Uplift Pressures, From RAS 128 or Sealed Calculations:
psf
psf
Maximum Design Pressure From NOA:
" :12 Roof Mean Height:
Parapet Walls: No 0 Yes Parapet wall Height:
Deck Type: I -5/8" Plywood— 1
° olc
Anchor Sheet Fastener / Bonding Material:
1 1/4° ring shank & 1 5/8" Tin caps
Insulation Base Layer Size & Thickness:
GAF materials
System Type:
-52.5
psf
EMI
ft.
1N /A
IN /A
1.5 &3 "ISO
Insulation Base Layer Fastener / Bonding Material:
ASTM Asphalt type IV
Insulation Top Layer Size & Thickness:
[N /A
Insulation Top Layer Fastener / Bonding Material:
1 1 Layer Stratavent
Base Sheet Fastener / Bonding Material:
oose Laid
Ply Sheet(s) & No. of Piy(s):
12 Layer of ply IV
Ply Sheet Fastener / Bonding Material:
ASTM Asphalt type IV
ft.
I Gaf Capsheet
Top Ply Fastening / Bonding Material:
1 ASTM Asphalt type IV
Surfacing:
SINGLE PLY MEMBRANE:
Single Ply Manufacturer / Type:
C N/A
Single Ply Sheet Width:
N/A
N/A
" 1/2 Sheet Width:
N /AI
mi
If
No. of Single Ply 1/2 sheets:
Single Ply Membrane Fastening / Bonding Material: • • ' • •
• • •
•_•_ _• • • • •
FASTENER SPACING FOR BASES ATTACHME 4T
❑ SINGLE PLY MEMBRANE ATTACHIIORIV1
•
••
▪ ••••
root, "o /c •
• •
• ''•• • •
• " o/c @ Laps & 4 _ • jo v�s• ��,, � " o/g
• •
3. Comer: 4 ° •
o/c @ Laps & rows " fE • " '
NUMBER OF FASTENERS PER INSULa'i10111 aOARD: • • • • •
•
3. Comer:
1. Field:
1. Field:
2. Perimeter:
0
" o/c @ Laps &
Insulation Fastener Type :
Edge Metal Material:
Edge Size:
Hook Strip Size:
Edge Metal Attachment:
2. Perimeter:
WOOD NAILER TYPE AND SIZE:
2x6 P.T.
EDGE & COPING METAL SIZES:
Coping Material:
Coping Size:
Hook Strip Si
Parapet Coping Metal Attachment:
1 N/A
Wood Nailer Fastener Type and Spacing:
#10 screws 8" OC
•
•
•
•
• •
• •
— Galvanized Metal-
-3" face 26 ga.—
—METAL EDGE HOOK STRIP N /A-
61 1/4" ring shank 4" O.C.
• •
•
•
•
1— PARAPET COPING METAL N /A—
— COPING METAL SIZE N /A-
- COPING METAL HOOK STRIP N /A—
• Insulated Nallable Deck
"Delivering Excellence Every Day"
Illustrate Components Noted and Details as Applicable:
Woodblocking, Gutter, Edge Terminations /Stripping /Flashing, Continuous Cleat, Cant Strip, Base Flashing,
Counterflashing, Coping, Etc.
Indicate: Mean Roof Height, Parapet Height, Height of Base Flashing, Component Material, Material
Thickness, Fastener Type, Fastener Spacing
Or: Submit Manufacturers Details that Comply with RAS -111 and Chapter 16.
Anchor Sheet
Base Layer
of Insulation
Top Layer
of Insulation
Top Ply
Interplies
High Velocity Hurricane Zone Roofing Permit Application Form
1
-al-- Drip Metal
�+-
Continuous
Cleat
Wood Nader
Roof Mean Height:
Drip Metal:
ft.
1 26 gauge galvanized 3" face
Continuous Cleat:
••••
• •
••••
IN /A
• • •
•• •
••• • •
•• •
• •_•. •
Surfacing:
granules
Top Ply:
Interplies:
Base Sheet:
Top Layer of Insulation:
ase Layer of Insulation:
Wood Nailer:
Wood Nailer Fastening:
Anchor Sheet:
Deck Type:
Wood
• •
•• • •
• •
• • •
•• •
•
•
• •
•
.• •
• • •
•
•• •
••••
•
mineral cap sheet • • • • •
•
•
•
•
•
12 Layers PLY IV
••••
1 1 Layer Stratavent Loose Laid
IN /A
I 5830
12x6 P.T.
I #10 Screws 8 "OC
#75 Base
•
•
•
M IA M
BUILDING CODE COMPLIANCE OFFICE (BCCO)
PRODUCT CONTROL DIVISION
NOTICE OF ACCEPTANCE (NOA)
(GAF Material Corporation)
1361 Alps Road
Wayne, NI 07470
MIAMI -DADE COUNTY, FLORIDA
METRO -DADE FLAGLER BUILDING
140 WEST FLAGLER STREET, SUITE 1603
MIAMI, FLORIDA 33130 -1563
(305) 375 -290I FAX (305) 375 -2908
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction
materials. The documentation submitted has been reviewed by the BCCO and accepted by the Building
Code and Product Review Committee to be used in Miami Dade County and other areas where allowed
by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County. Product
Control Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade•Cotnty)
reserve the right to have this product or material tested for quality assurance purposes It this pf?4i t or
material fails to perform in the accepted manner, the manufacturer will incur the rap 9e of such tds ing
and the AHJ may immediately revoke, modify, or suspend the use of such prodilcf o'r materuil
their jurisdiction. BORA reserves the right to revoke this acceptance, if it is determm4by MitDlkde
County Product Control Division that this product or material fails to meet the, pirementa.of the
applicable building code. • • • • • • •
•
This product is approved as described herein, and has been designed to comply widtheFloridafivalipg
Code and the High Velocity Hurricane Zone of the Florida Building Code. •
• • • • • • •
(DESCRIPTION: GAF Conventional Built -Up Roof System for Wood Decks.) 6 ' •....'
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state
and following statement: "Miami -Dade County Product Control Approved ", unless otherwise noted
herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has
been no change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or
change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an
endorsement of any product, for sales, advertising or any other purposes shall automatically terminate
this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of
NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and
followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is
displayed, then it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This NOA renews and revises NOA No. 03- 0501.05 and consists of paged 1 throygh 19.
The submitted documentation was reviewed by Jorge L. Acebo.
(NOA; :) (O74219.09)
(Expiration Datel) (11/04/13)
Approval Date: 03/20108
Page 1 of 19
•
•
• ••
• •
•
•
•
• •
ROOFING SYSTEM APPROVAL
Category:
Sub- Cate2orv:
peck Tvne:
Maximum Design Prc sgre
Roofing
BUR
Wood
-75 psf
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
TABLE 1
Test
Product Almensions Sneciflcation
Leak BusterTM MatrixTM
307 Premium Asphalt
Primer
GAF Mineral ShieldTM
Granules
Leak BusterTM Matrix"'
305 Fibered Asphalt
Emulsion
Leak BusterTM Matrix"'
303 Premium Fibered
Aluminum Roof Coating
LeakBusterm MatrixTM 55
• 322 Elastomeric Roof
Coating
LeakBusterT' MatrixTM
Select Asphalt Emulsion
Fibered 306
Leak Buster"' Matrix"'
204 Wet/Dry Roof
Cement
RUBEROID Modified
Bitumen Flashing
Cement
LeakBusterm Matrix"'
201 Premium SBS
Flashing Cement
GAFGLAS #75
3, 5, 55 gallons
60 & 1001b. bags
5 gallons
1, 5 gallons
55 gallons
1, 5 gallons
5 gallons
5 gallons
ASTM D 41
ASTM D 1863
ASTM 1227
Product
Description
Asphalt concrete primer used to promote
adhesion of asphalt in built -up roofing.
Granules for surfacing of exposed Agra,
cold process cement of emu" leion. C `V • • •
Mineral Shield"' Gratlylp�sja11 be us84lfor •
flashing applications (IAA.. • • •
Surface coating for smc oth.yrfaceei f§.
•••• ••••
ASTM D 2824 Fibered aluminum coa4ngr, •
• •
• •
. • •
•• • •
lions Elastomeric roof coating.
Asphalt emulsion fibered.
ASTM D -4586 Refined asphalt blended with a mineral
ASTM D -3409 stabilizer and fibers. Permits adhesion to
wet and dry surfaces.
ASTM D 4586 Fiber reinforced, polymer modified Flashing
cement
ASTM D 4586 Asphalt flashing Cement
• •
.• ••
•. •
•
•. •
•
• •
•
••••
• •
••••
39.37" (1 meter) ASTM D 4601 Asphalt impregnated and coated glass mat
wide base sheet.
NOA No.: 07- 1219.09
Expiration Date: 11/04/13
Approval Date: 03/20/08
Page 2 of 19
•
•
•
• •
•••••
•
•
•
• ••
•
Product
GAFGLAS
ULTIMATM Base Sheet
GAFGLAS
Flex P1yT" 6
GAFGLAS Ply 4
GAFGLAS Mineral
Surfaced Cap Sheet
GAFGLAS
EnergyCapT" Mineral
Surfaced Cap Sheet
GAFGLAS
STRATAVENT
EliminatorTM Perforated
GAFGLAS® Flashing
GAFGLAS
STRATAVENT
Eliminator"' Nailable
RUBEROID SBS
Heat-Weld"' Smooth
RUBEROID SBS
Heat- We1dTM Granule
RUBEROID SBS
Heat- WeIdrm 170 FR
RUBEROID SBS
Heat We1dTM PLUS
RUBEROID SBS
Heat- We1dTM PLUS FR.
RUBEROID SBS
Heat- We1dTM 25
RUBEROID Modified
Base Sheet
OADEG0
APPROVED
Dimensions
39.37" (1 meter)
wide
39.37" (1 meter)
wide
39.37" (1 meter)
wide
39.37" (1 meter)
wide
39:37" (1 meter)
wide
39.37" (1 meter)
wide
Various
39.37" (1 meter)
wide
1 meter. (39.37 ")
wide
1 meter (39.37 ")
wide
1 meter (39.37 ")
wide
1 meter (39.37 ")
wide
1 meter (39.37 ")
wide
1 meter (39.37 ")
wide
39.37" (1 meter)
wide
Test
Specification
ASTM D4601
ASTM D 2178
ASTM D 2178
ASTM D 3909
ASTM D 3909
ASTM D 4897
D 3672
ASTM D 4897
D3672
ASTM D -6164
ASTIVI D -6164
ASTM D -6164
ASTM D -6164
ASTM D -6164
ASTM D -6164
ASTM D4601,
Type II, UL
Type G2 BUR
Product
Description
Asphalt impregnated and coated, fiberglass
base sheet
Type VI asphalt impregnated glass felt with
asphalt coating.
Type IV asphalt impregnated glass felt with
asphalt coating.
Asphalt coated, glass fiber mat cap sheet
surfaced with mineral granules.
Asphalt coated, glass fiber max cap sheet
surfaced with mineral granules with factory
applied layer of TOPCOAT
Fiberglass base sheet impregnated and
coated on both sides with asphalt.niifaced
on the bottom side with mfineral uf"
embedded in asphaltiadpg with fgry
perforations. •
Asphalt coated glass fibas s fat flateing$heet ••••••
available in three sizes• • • • • • • •
Fiberglass base sheet ifii nated iW •
coated on both sides w$h asphalt gu'aced
on the bottom side wiii Antral Wnulos
embedded in asphaltic.coating. ""
Non -Woven Polyester xne coated pith*.
polymer - modified asphalt and smodt t"
surfaced.
Non -Woven Polyester mat coated with
polymer modified asphalt and surfaced with
mineral granules.
Non -Woven Polyester mat coated with fire
retardant polymer modified asphalt and
surfaced with mineral granules.
Non -Woven Polyester mat coated with .
polymer modified asphalt and surfaced with
mineral granules.
Non -Woven Polyester mat coated with fire
retardant polymer modified asphalt and
surfaced with mineral granules.
Non -Woven Polyester mat coated with
polymer - modified asphalt and smooth
surfaced.
Premium glass fiber reinforced SBS
modified base sheet
NOA No.: 07- 1219.09
Expiration Date: 11/04/13
Approval Date: 03/20/08
Page 3 of 19
• •
•
•
•
• •
•
•
Product
RUBEROID 20
RUBEROID Mop
Granule
RUBEROID Mop Plus
(Granule)
RUBERO1D MOP
Smooth
RUBEROID MOP
170FR
RUBEROID MOP FR
RUBEROID TORCH
Smooth
RUBEROID TORCH
Granule
RUBEROID' TORCH
PLUS (Granule)
RUBEROID TORCH
FR
RUBEROID
TORCH
RUBBROID 30
RUBEROID 30 FR
RUBEROID'
ULTRACLAD
RUBEROID Dual FR
Vent Stacks (metal and
plastic)
Dimensions
3937" (l meter)
wide
39.37" (1 meter)
wide
39.37" (1 meter)
wide
39.37" (1 meter)
wide
39.37" (1 meter)
wide
39.37" (1 meter)
wide
39.37" (1 meter)
wide
39.37" (1 meter)
wide
39.37 "(1 meter)
wide
39.37" (1 meter)
wide
3937" (1 meter)
Wide
39.37" (1 meter)
wide
39.37" (1 meter)
wide
39.37" (1 meter)
wide
39.37" (1 meter)
Wide
Test
,Specification
ASTM D 6163
ASTM D 5.147
ASTM D 6222
ASTM D 5147
ASTM D 6222
ASTM D 5147
ASTM D 6164
ASTM D 5147
ASTM D 6164
ASTM D 5147
ASTM D 6164
ASTM D 5147
ASTM D 5147
ASTM D 5147
ASTM D 6222
ASTM D 5147
ASTM D 6222
ASTM D 5147
ASTM D 6222
ASTM D 5147
ASTM D 6163
ASTM D 5147
ASTM D 6163
ASTM D 5147
ASTM D 6298
ASTM D 5147
ASTM D 6164
ASTM D 5147
TAS 100(A)
ASTM D 1929
ASTM D 635
Product
Description
SBS modified asphalt base sheet and
interply sheet reinforce with a glass fiber
mat.
Non -woven polyester mat coated with
polymer modified asphalt and surfaced with
mineral granules.
Non -woven polyester mat coated with
polymer modified asphalt and surfaced with
mineral granules.
Non -woven polyester mat coated with
polymer - modified asphalt and smooth
surfaced.
Non -Woven polyester mat coated with fire
retardant polymer modified asphalt and
surfaced with mineral granules.
Non -Woven polyester mat coated with fire
retardant polymer modified asphalt and
surfaced with mineral granules.
Heavy duty, polyester reinforced, as;Oliitit .
modified bitumen memo ;ine,mooth: : "
surface. •
Asphalt impregnated, ceata'd#e1t, surfaced
with mineral granule. •••••• • .... • •
Heavy duty, polyester reh' fenced, asphalt
modified bitumen membriVgranud8' • •
.• •• •• • •
surface.
Heavy duty, polyester ibinfor4ed, cpatecl
with fire retardant aspl elt modifiedMit6tden
membrane, granule surf t e. • •••••• •
Heavy duty, polyester reinforced, edited
with fire retardant asphalt modified bitumen
membrane, granule surface.
Non -woven fiberglass mat coated with
polymer modified asphalt and surfaced with
mineral granules.
Non -woven fiberglass mat coated with fire
retardant polymer modified asphalt and
surfaced with mineral granules.
Woven fiberglass mat coated with Polymer
modified asphalt and surfaced with
aluminum, copper or stainless steel foil.
Non -woven polyester and fiberglass mat
coated with file retardant, polymer modified
asphalt and surfaced with mineral granules.
One way valve vent used to relieve built -up
pressure within the roof system. GAF Vent
Stacks are available in metal or plastic.
NOA No.: 07- 1219.09
Expiration Date: 11/04/13
Approval Date: 03/20/08
Page 4 of 19
•
••
•
•
Product
Leak Buster"' MatrixTM
302 Non Fibered
Aluminum Roof Coating
GAF Built -Up Roofmg
Asphalt
RUBERO1D MOD
Asphalt, Asphalt L &
Asphalt P
Leak Buster"' MatrixTM
602
Leak BusterTM Matrix"
715
LeakBusterT' Matrix"
531 WeatherCoteTM
SeamCote"
FireOutm
VersaShiele
VersaShield FB -1S
VersaShield FB -2S
TOPCOAT FireShiele
MB
Leak Buster"' MatrixTM
201 SBS Flashing
Cement
Leak Buster"' Matri
102 SBS Adhesive
Leak Buster" Matrix"'
202 SBS Flashing
Cement
Leak Buster"' MatrixTM
203 Plastic Roof Cement
Leak Buster" MatrixTM
103 Cold Process
Adhesive
Jd
APPROVED
Dimensions
5 gallons
1001b. cartons,
bulk
60 lb. kegs
5 gallons
5 gallons
2 gallons
2, 5 gallons
5, 55 gallons
350 sq ft. roll
350 sg ft. roll
350 sq ft. roll
5, 55 gallons
5 gallons
5 gallons
5 gallons
5 gallons
5 gallons
Test
Specification
ASTM D2824,
Type 1
ASTM D312,
Types I, II, HI
and IV
proprietary
ASTM D -412
ASTM D -21 -96
ASTM D1475
ASTM E -1644
ASTM D3019
ASTM D3019
ASTM D4586
ASTM D4586
ASTM D3019
Product
Description
Non- fibered aluminum pigmented, asphalt
roof coating.
Interply mopping and surfacing asphalt.
SEBS modified asphalt.
Surface coating for smooth surfaced and
mineral surfaced roofs.
Surface coating for smooth surfaced and
mineral surfaced roofs.
Surface coating for smooth surfaced and
mineral surfaced roofs.
Elastomeric roofing membrane.
Low VOC, fire barrier voaah g.
Non - Asphaltic Fiberglass-lived
Underlayment. • • • •
Non - Asphaltic Fiberglaas.Based
Underlayment. • •
Non - Asphaltic FibergEsased
Underlayment. • • •
Elastomeric roofing membrane
• •
•• •
Cold Applied Asphalt Adhesive.
.. ••
• •
• ..•
.. •
• • •
•• •
• •
•
. •••
.. •.
.•. •
•.
••
•
•
• • • •
• • •
• • •.
Cold Applied Modified SEBS Asphalt
Adhesive — Flashing Grade.
Cold Applied Modified SEBS Asphalt
Adhesive.
Cold Applied Modified SEES Asphalt
Adhesive — Flashing Grade.
Standard Plastic Asphalt Roofing Cement
NOA No.: 07- 1219.09
Expiration Date: 11/04/13
Approval Date: 03/20/08
Page5of 19
Product
Leak BusterTM MatrixTM
303 Fibered Aluminum
Roof Coating
Leak EusterTM MatrixTM
304 Non Fibered
Aluminum Roof Coating
APPROVED INSULATIONS:
Product Name
EnergyGuardTM RA, RN
Composite A & N
EnergyGuardTM Fiberboard
EnergyGuardTM Permalite
EnergyGuardTM GAFCANTTM
EnergyGuarem Permalite Recover
Board
EnergyGuardTM Tapered Edge Strip
EnergyGuardTM Perlite
EnergyGuardTM High Density
Fiberboard
EnergyGuardTM Composite
EnergyGuardTM Composite RA
Wood Fiber
High Density Wood Fiberboard
Perlite Insulation
Dens Deck, Dens Deck Prime,
Dens Deck ® Dura GuardTM
Structodek
SecurockTM
Test
Dimensions Specification
5 gallons ASTM D 2824
5 gallons
ASTM D2824, Non-fibered aluminum pigmented, asphalt
Type I roof coating.
Table 2
Product Description;
Polyisocyanurate foam insulation
Polyisocyanurate foam insulation with
high density fiberboard or Permalite
perlite insulation.
Fiberboard insulation.
Perlite insulation board.
Cut perlite board
Perlite recover board
Tapered perlite board
Perlite insulation board
High density wood fiberboard insulation.
Polyisocyanurate /wood fiberboard
composite
Polyisocyanurate /wood fiberboard
composite
Wood fiber insulation board
Wood fiber insulation board
Perlite insulation board
Water resistant gypsum board
Wood fiber insulation board
Fiber reinforced roof board
Product
escrintion
Fibered aluminum coating.
Manufacturer
(With Current NOA)
BMCA '
GAF Materials Corp.
C Material's.02)1p.
GAP Mhteriatseprp.
GAF.'Materials Corp.
GAE1Silaterials t''&p.
.. • •
GAVMaterials Carp.
GAF'Materials Cgrp.
C AF Materials Corp
• .
••••
BMCA
BMCA
generic
generic
generic
G -P Gypsum Corp
Knight Celotex
UM Corporation
NOA No.: 07- 1219.09
Expiration Date: 11/04/13
Approval Date: 03/20/08
Page 6 of 19
•
•
•
• •
• •
.'
•
• •
• •
APPROVED FASTENERS:
Fastener
Number
1.
2.
3.
4.
5.
6.
IRT of S. Fl.
Product
Name
Drill -TecTM #12 Standard,
#14 and #15 extra Heavy
Duty Fastener , Heavy
Duty Roofeng•Fastener
Drill -TecTM ASAP
Drill -TecTM #12 or #14
Standard screws with
AccuTrac Plate
Drill -TecTM Galvalume
Plates
Drill-TecTM
Polypropylene Plates
Drill -TecTM AccuTrac
Plate
EVIDENCE SUBMITTED:
Test Auencv
Factory Mutual Research Corp.
PRI Asphalt Technologies, Inc.
TABLE 3
Product
Description
Insulation fastener and
Base Play fastener for
steel, wood & concrete
decks.
Pre - assembled Drill -
TecTM Fasteners and
metal and plastic plates.
Base sheet fastening
assembly.
Round Galvalume stress
plates.
Round polypropylene
stress plates.
Square Galvalume
coated steel plate.
Test Identifier
J.I. 2B8A4.AM
J.I. 3B9Q1.AM
J.I. ODOA8.AM
J.I.ODIA8.AM
J.I.0Y9Q5.AM
3029832
GAF - 012 -02 -02
GAF - 020 -02 -01
02 -005
02 -014
Manufacturer
Dimensions (With Current NOA)
Various GAF Materials Corp.
Various GAF Materials Corp.
Various GAF Materials Corp.
3" and 3 GAF Materials Corp.
3" and 3 /" GAF Materials Corp.
••••
. .
. . ••••
• • •
3" Square GAP MkterialV .
• • •
• •
• •
Description • •
4470
4470
4470
4470 -TAS 114
4470 -TAS 114
4470 - TAS • 114
Physical Properties
ASTM D 4977
TAS 114
TAS 114
•
••.•
• •
.•.
• •
•• ••
•
••
••••
• •
.•
•• •
• • •
•• •
•
• •
bate
'...•
07
.02.97
01.08.98
07.09.99
07.29:94
04.01.98
05.11.07
11.06.01
02.01.02
01.18.02
03.22.02
NOA No.: 07- 1219.09
Expiration Date: 11/04113
Approval Date: 0312008
Page 7 of 19
•
•
•
•
..
•
• •
••••••
•
•
•
•
•
•
•
APPROVED ASSEMBLIES
Deck Type 1I: Wood, Insulated •
Deck Description: 14 42" or greater plywood or wood plank
System Type A: Anchor sheet mechanically fastened, all layers of insulation adhered with
approved asphalt.
All General and System Limitations shall apply.
One or more layers of any of the following insulations. .
Insulation Layer (Table 2) Insulation Fasteners Fastener
(When applicable: Steel plate only =5, plastic plate only (Table 3) Density /ft
ffiP)
(EnergyGuardTM, EnergyGuard' (Composite, EverGuard ISO, 'EnergyGuard (RA,)
(EnergyGuard Composite)
(Minim ";thick) N/A N/A
EnergyGuardTM High Density Wood Fiber, EnergyGuardmi Recover Board, Wood Fiber,
Minimum 4" thick N/A rT/t • •
:•••.:
. .
N/A ••
EnergyGuardTM Perlite
Minimum 3 4" thick N/A
Fiberglas (Min. 15 / 16 " thick) N/A • • • • • • .1il •.
Note: All insulation shall be adhered to the anchor sheet in full mopping of apprti hot asphalt
within the EVT range and at a rate of 20-40 Ibs/100 ft'. Please refer to Roofing'Apiplication• • •
Standard RAS 117 for insulation attachment. Insulation listed as base layer onIrshaU be used only
as base layers with a second layer of approved top layer insulation installed as the final me ttleri ne
substrate. Composite insulation panels may be used as a top layer placed with tile• : • • • •
polyisocyanurate side facing down. GAF requires either a ply of GAFGLAS STRATAVLAt..
EliminatorTM Perforated laid dry or a layer of EnergyGuardTM Perlite or wood fiber overlay board
on all isocyanurate applications.
Fire Barrier: FireOutTM Fire Barrier Coating, VersaShield ® Nan - Asphaltic Fiberglass -Based
(optional) Underlayment or SecurockTM.
Anchor sheet: GAFGLAS #80 ULTIMATM Base Sheet, STRATAVENT® EliminatorTm
Nailable, RUBEROID Modified Base Sheet, RUBEROID 20, RUBEROID
Heat- WeldTM Smooth or RUBEROID Heat- WeIdTM 25 base sheet mechanically
fastened as described below;
Fastening Options: GAFGLAS Ply 4, GAFGLAS Flex P1yTM 6, GAFGLAS #75 Base Sheet or
any of above Anchor sheets attached to deck with approved annular ring shank
nails and tin caps at a fastener spacing of 9" o.c. at the lap staggered and in two
rows 12" o.c. in the field.
(Maximum Design Pressure —45 psf, See General Limitation #7)
APPROVED
NOA No.: 07- 1219.09
Expiration Date: 11/04/13
Approval Date: 03/20/08
Page 8 of 19
•
•
• •
• •
•
. •
• •
Fastening Options: GAFGLAS Ply 4, GAFGLAS Flex PIyTM 6, GAFGLAS #75 Base Sheet or
any of above Anchor sheets attached to deck with Drill -Teczm #12 standard, #14
or # 15 Screws and 3" Drill-TecTm steel plate or Drill -Teem AccuTrac Plates,
12" o.c. in 3 rows. One row is in the 2" side lap. The other rows are equally
spaced approximately 12" o.c. in the field of the sheet.
(Maximum Design Pressure 43 of See General Limitation #7)
(GAFGLAS` Flex PIyTM`6 GAFGLAS' #75 Base Sheet or any of above Anchor)
(sheets attached to deck with approved annular ring shank nails and tin caps at a).
(fastener spacing of 9" o.c. at the 4" lap staggered and in two rows 9" o.c. in the)
(field.)
((Max imum Design Pressure -52.5 psf, See General Limitation #7))
GAFGLAS #80ULTIMATh, RUBEROID 20, RUBEROID Mop Smooth, base
sheet attached to deck with approved PA" annular ring shank nails and inverted
3" steel plate at a fastener spacing of 9" o.c. at the 4" lap and in two rows
staggered with a fastener spacing of 9" o.c. in the center of the membrane.
(Maximum Design Pressure -60 psf, See General Limitation #7)
GAFGLAS #75 Base Sheet or any of above Anchor sheets attached to deck with
Drill -TecTM #12 standard, #14 or # 15 Screws and 3" Drill- TecTm steel plate or
Drill -TecTM AccuTrac PIates, 12" o.c. in 4 rows. One row is in the 2" side lap.
The other rows are equally spaced approximately 9" o.c. in the field of the nett.
(Maximum Design Pressure - pal, See General LimitatI A . : •
Any of above Anchor sheets attached to deck approved annula: i it shank n
and 3" inverted Drill -TecTM insulation plates at a fastener spag of 9" o at the
4" lap staggered in two rows 9" in the field. . • • „
(Maximum Design Pressure -60 psf, See General Limitation 7i. ••••••
GAFGLAS #75 Base Sheet or any of above Anchor sheetsattaWJd to decd with
Drill -TecTM #12 standard, #14 or # 15 Screws and 3" Drill4ecitn steel plate or
Drill -TecTM AccuTrac Plates, 8" o.c. in 4 rows. One row is In 41%2" si 1*ap.
The other rows are equally spaced approximately 9" o.c. in We field of t}ih•$Ittpt.
(Maximum Design Pressure -75 psf, See General Limitation #7) •' • •
Base Sheet (Optional) Install one ply of GAFGLAS #75, GAFGLAS #80 ULTIMAT"I
Base Sheet, GAFGLAS (STRATAVENT' EliminatorT$ (Perforated,)
RUBEROID Modified Base Sheet, RUBEROID Mop Smooth, RUBEROIDO
20 RUBEROID Heat- WeIdTM Smooth or RUBEROII3 Heat We1ddM directly
over the top layer of insulation. Adhere with any approved mopping asphalt
applied within the EVT range and at a rate of 20-40 lbsisq; (see General
Limitation #4).
•
Ply Sheet: (One or more plies GAFGLAS` PLY 4,)GAFGLAS Flex PIyTM 6 sheet, #80
Ultima, RUBEROID Mop Smooth or RUBEROID 20 adhered in a full
mopping of approved asphalt applied within the EVT range and at a rate of 20-40
lbsJsq.
NOA No.: 07 1219.09
Expiration Date: 11/0443 .
Approval Date: 03/20/08
Page 9 of 19
Cap Sheet (Optional) (One ply of GAFGLAS " Mineral Surfaced Cap Sheet or
GAFGLAS' EnergyCapTM Mineral Surfaced Cap Sheet adhered in a full
mopping of approved asphalt applied within the EVT range and at a rate of
20 -40 lbs. /sq.
Surfacing: (Optional, required if RUBEROID MOP Smooth or RUBEROID 20 is top
membrane) Install one of the following:
1. Gravel or slag applied at 400 lbs.sq. and 300 lbs. /sq. respectively in
a flood coat of approved asphalt at 60 lbs./sq. or applied in a flood
coat of Leak Buster"( Matrix"' 103 Cold Process Adhesive applied
at a rate of 3 galJsq.
2. GAFGLAS Mineral Surfaced Cap Sheet, GAFGLAS Energy Cap
Mineral Surfaced Capsheet adhered in a full mopping of approved
asphalt applied within the EVT range and at a rate of 20 -40 lbs.sq.
3. Leak BusterTM MatrixTM 303 Premium Fibered Aluminum Roof
Coating, at 1.5 gal./sq.
4. Leak Buster"' MatrixTM 715 , Leak Busterm MatrixTM 322,
TOPCOAT MB +, TOPCOAT Fireshield Elastomeric Roofing
Membrane, applied at 1 to 1.5 gal./sq.
5. Leak Buster"' MatrixTM 602 MB Xtra Elastomeric Roofing • • • • • •
Membrane, EnergyCote® roof coating applied a1 1 to l galJsq' • •
•
6. TOPCOAT Surface Seal, TOPCOAT' Fireshiekl, Sil.Solvent •.; •
based Elastomeric Roofing Membrane applied aPkv' 6 galJsq • • •
7. Advance Green Technologies Photovoltaic LahNilie • •
collector auxiliary roof equipment installed in • cemplianot with • •
manufacturer's specifications and applicable Buitdirrgtodes • • • • •
Maximum Design
Pressure: See Fastening above.
• • • •
• • •
•• •
•
•
•
••••
• •
NOA No.: 07- 1219.09
Expiration Date: 11/04/13
Approval Date: 03/20/08
Page 10 of 19
•
•
WOOD DECK SYSTEM LIMITATIONS:
1 A slip sheet is required with Ply 4 and Flex P1yTM 6 when used as a mechanically fastened base or anchor
sheet.
2. Minimum '' /a" Dens DeckTM or %Z Type X gypsum board is acceptable to be installed directly over the
wood deck.
GENERAL LIMITATIONS:
I . Fire classification is not part of this acceptance, refer to a current Approved Roofing Materials Directory
for fire ratings of this product.
2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with
Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved
asphalt applied within the EVT range and at a rate of 20-40 lbs. /sq., or mechanically attached using the
fastening pattern of the top layer
3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt,
panel size shall be 4' x 4' maximum.
4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam
insulations when the base sheet is fully mopped. If no recovery board is used the base sheet shall be
applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8"
ribbons in three rows, one at each sidelap and one down the center of the sheet allowing a continuous
area of ventilation. Encircling f the strips is not acceptable. ""
g p ptable. A 6" break shall.be Rlaced ave�y12' in
each ribbon to allow cross ventilation. Asphalt application of either system shall Beat minir w n rate of • •
121bs. /sq. Note: Spot attached systems shall be limited to a maximum design'pi essure of -4 4,sf. •
5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Fd(') value of 275 •. •
lbf., as tested in compliance with Testing Application Standard TAS 105. If the fasas &t&i value, Wflsld- • •
.... •••
tested,
are below 2751bf. insulation attachment shall not be acceptable. • •• •
6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attac1tm it is b @d,pn a
minimum fastener resistance value in conjunction with the maximum design valueka ted•within a specific • •
•
system. Should the fastener resistance be less than that required, as determined by the DuildirQit1ial,
a revised fastener spacing, prepared, signed and sealed by a Florida Registered Enkinedr, Architect, or • •
Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the witjf&awal • •
resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with
Roofing Application Standard RAS 117.
7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas.
Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with
Roofing Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered
Professional Engineer, Registered Architect, or Registered' Roof Consultant (When this limitation is
specifically referred within this NOA, General Limitation #9 will not be applicable.)
8. All attachment and sizing of perimeter milers, metal profile, and/or flashing termination designs shall
conform with Roofing Application Standard RAS 111 and applicable wind load requirements.
9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (Le. field,
perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced
fastening at enhanced pressure zones (Le. perimeters, extended corners and corners). (When this
limitation is specifically referred within this NOA, General Limitation #7 will not be applicable.)
10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building
Code and Rule 913-72 of the Florida Administrative Code.
END OF THIS ACCEPTANCE
NOA No.: 07- 1219.09
Expiration Date: 11/04/13
Approval Date: 03/20/08
Page 19 of 19
• TGFIF.R1306 - Roofing Systems
Bottom ply or base sheet may be solid mopped, spot mopped or mechanically fastened.
Unless otherwise indicated, all insulations may be hot mopped or mechanically fastened.
"GAFGLAS Flashing" or "Ruberoid" may be used for flashing in any of the Class A, B or C systems listed below.
When "perlite" is referenced, this includes "GAFTEMP PERMALITE ®" or any other UL Classified perlite insulation.
Crushed stone or slag are suitable alternates for gravel in any of the Class A, B or C systems listed.
Structural cement fiber building units are considered suitable to be included as a deck in the following Class A, B or C
systems listed over C -15/32 or NC.
The use of gypsum board under any of the following Class A, B or C systems does not adversely effect the rating. The use of
t / -in. minimum gypsum board is an acceptable alternate for insulation over C -15/32 decks.
The use of polystyrene insulation board between minimum 3/4-in. thick perlite board and deck with rosin paper (perlite/
rosin paper /polystyrene /perlite) is a suitable alternate for polyisocyanurate board in the following Class A, B or C systems.
"EnergyGuard RA" or "Tapered EnergyGuard RA" or "EnergyGuard Composite RA" may be substituted for any
Atlas polyisocyanurate insulation in any of the following Classifications.
Trumbull "Perma Mop" may be utilized with any of the following "Asphalt Felt Systems with Hot Roofing Asphalt ".
GAFGLAS #80 Premium Base Sheet may be used in any of the following systems. • •••• •
• • ••••
"GAFGLAS Flex Ply 6" and "Tri-Ply Ultra - Flexible Ply 6" are suitable alternates to "GAFGLAS Ply 6 ". • • • ••• • • • • •
•
" GAFTEMP Permalite Recover Board" may be used in lieu of any perlite insulation in any of the follo • •
• •• •••• • •
• • •
Unless otherwise indicated, any of the "Asphalt Felt Systems with Hot Roofing Asphalt" may be surf jl wJh "Fire Weld MB" • •
at 21/2 to 3 -gal /100 -ft •• ••••••
Hot roofing asphalt, for use with organic and glass felts or modified bitumen membranes.
"Ruberoid Heat Weld" SBS roofing membrane may be used in lieu of "Ruberoid Mop" SBS products in any
applicable Classification.
1. Deck: C -15/32 Incline: 3
Insulation (Optional): — One or more layers perlite or wood fiber or glass fiber or polyisocyanurate or urethane or perlite/
polyisocyanurate composite or perlite /urethane composite or wood fiber /polyisocyanurate composite or phenolic, any
thickness.
Ply Sheet: — Three or more plies Type G1 or "GAFGLAS Ply 4" or "Tri -Ply Ply 4" or "GAFGLAS Ply 6" hot mopped.
Surfacing: — Gravel.
2. Deck: C- 15/32,
(Incline: 2)
Insulation (Optional): - One or more layera perlite or wood fiber or glass fiber or polyisocyanurate or urethane or perlite /)
polyisocyanurate composite or perlite /urethane composite or wood fiber / polyisocyanurate composite or phenolic, any)
thickness.)
(Ply Sheet: - Three or more plies Type G1 or " GAFGLAS Ply 4" or "Tri -Ply Ply 4" or "GAFGLAS Ply 6 ".)
(Cap Sheet: — One ply Type G3 " GAFGLAS Mineral Surfaced Cap Sheet" or "Tri-Ply Mineral Surfaced Cap Sheet %)
3. Deck: NC Incline: 2
Class A, B and C
Class A
http: / /datebase.ul.com/cgi- bin /XYV/ Sample[ ed LISEXT /1...&versicnwersionless& parent _id= 1073993597&sequence = (2 of 55) [9/17/2008 3:03:18 PM]
• • •
• • • •
• •
• • •
•• •
•
•
• ••••
•••
• •
•
•
•
• •
• •
TGFU.R1306 - Roofing Systems
Insulation (Optional): — One or more layers perlite, wood fiber, glass fiber, polyisocyanurate, urethane, perlite/
polyisocyanurate composite, perlite /urethane composite, wood fiber / polyisocyanurate composite, phenolic, 2 -in. maximum.
Ply Sheet: — Two or more plies Type G1 " GAFGLAS Ply 4" or "Tri -Pty PIy 4 ", " GAFGLAS Ply 6 ".
Cap Sheet: — One ply Type G3 " GAFGLAS Mineral Surfaced Cap Sheet" or "Tri -PIy Mineral Surfaced Cap Sheet ".
4. Deck: NC Incline: 1/2
Insulation: — One or two layers "Isotherm R ", any thickness, hot mopped.
PIy Sheet: — Any UL Classified gravel surfaced Class A asphalt glass fiber mat system.
5. Deck: C -15/32 Incline: 1
Slip Sheet (Optional): — Red rosin paper, nailed to deck.
Base Sheet: — One ply Type G2 "GAFGLAS #75 Base Sheet" or "Tri -PIy #75 Base Sheet" (may be nailed).
PIy Sheet: — One or more plies Type G1 " GAFGLAS PIy 4" or "Tri -PIy PIy 4" or GAFGLAS Ply 6 ".
Cap Sheet: — One ply Type G3 " GAFGLAS Mineral Surfaced Cap Sheet" or "Tri -PIy Mineral Surfaced Cap Sheet ".
6. Deck: NC Incline: 3
Base Sheet: — One ply Type G2 "GAFGLAS #75 Base Sheet" or "Tri -PIy #75 Base Sheet ".
Ply Sheet: — One or more plies Type G1 " GAFGLAS Ply 4" or 'Tri -PIy PIy 4" or " GAFGLAS Ply 6 ".
Cap Sheet: — One ply Type G3 " GAFGLAS Mineral Surfaced Cap Sheet" or "Tri -Ply Mineral Surfaced Cap Sheet ".
7. Deck: C -15/32 Incline: 2
•••• •
• Insulation: — One or more layers perlite, glass fiber, polyisocyanurate, urethane, perlite /po6Ocypnurat ..c �omposite,'MAIN/
urethane composite, phenolic, 1.0 in. min (offset a minimum of 6 -in. from plywood deck joins +•• .•� '•
Base Sheet: — One or more plies Type G1 or Type G2 or Type G3. •
Membrane: — One or more plies "Ruberoid Torch Smooth" or "Ruberoid Torch Granule" or ' Torch (granule P.s" or
"Ruberoid Mop Smooth" or "Ruberoid Mop Granule" or "Ruberoid Mop Plus Granule" or "Roofl fc'h'SBS Mge fits Granular on
"Tri -PIy SBS Modified Bitumen Membrane" or "RoofMatch APP Modified Granular" or "Tri-PIy Tli W or "Tri - Ppy -4 ".
Cap Sheet: — Type G3 "GAFGLAS Mineral Surfaced Cap Sheet" or "Tri -Ply Mineral Surfaced tbje31:eet" FrotsrDeeped • •
•• •• •• •
8. Deck: C -15/32 Incline: 2
• • •
Insulation (Optional): — One or more layers perlite or wood fiber or glass fiber or polyisoc?dnurete or urethane or igrlitr3i
polyisocyanurate composite or perlite /urethane composite or wood fiber /polyisocyanurate composite or p?1emaile, any
thickness.
Base Sheet: — Two or more plies Type G2 or Type G3.
PIy Sheet (Optional): — One or more plies Type G1.
Membrane: — One or more plies "Ruberoid Torch Smooth" or "Ruberoid Torch Granule" or "Ruberoid Torch Granule Pius" or
"Ruberoid Mop Smooth" or "Ruberoid Mop Granule" or "Ruberoid Mop Plus Granule" or "RoofMatch SBS Modified Granular" or
"Tri -PIy SBS Modified Bitumen Membrane" or "RoofMatch APP Modified Granular" or "Tri -Ply TP -4G" or "Tri -PIy TP -4 ".
Cap Sheet: — Type G3 " GAFGLAS Mineral Surfaced Cap Sheet" or "Tri -PIy Mineral Surfaced Cap Sheet" hot mopped.
9. Deck: NC Incline: 2
Insulation (Optional): — Perlite or glass fiber or polyisocyanurate or wood fiber or mechanically fastened, any thickness.
Base Sheet: — One or more plies Type G2, "GAFGLASS #75 Base Sheet" or "Tri -PIy #75 Base Sheet ".
Ply Sheet: — One or more plies Type G1 "GAFGLAS PIy 4" or "Tri -PIy PIy 4" or "GAFGLAS Ply 6 ".
Cap Sheet: — Type G3 " GAFGLAS Mineral Surfaced Cap Sheet" or "Tri -PIy Mineral Surfaced Cap Sheet" hot mopped.
Surfacing: — "Fireshield MB" applied at 21/2 to 3.0 -gal. /100 -ft
10. Deck: C -15/32 Incline: 1
Insulation (Optional): — One or more layers perlite or wood fiber or glass fiber or polyisocyanurate or urethane or perlite/
polyisocyanurate composite or perlite /urethane composite or wood fiber /polyisocyanurate composite or phenolic, any
thickness.
PIy Sheet: — Three or more plies Type G1 "GAFGLAS PIy 4" or "Tri-Ply Ply 4" or " GAFGLAS PIy 6 ".
Cap Sheet: — "EnergyCap Mineral Surfaced Cap Sheet ".
bnp : / /dambase.ul.com/cgi- bin /XYV/ template/ LISEXT /1...Bcversioawersionless tparent id- 1073993597&sequencel (3 of 55) [9/17/2008 3:03:IS PMI
• • •
• • • •
• •
•