Loading...
301 NE 102 St (4)Date(0 ' `Za Job Address 39l WO7 oz-sf Tax Folio 1 I — P60:-7() .(01 ax 1/437 Legal Description �C )M D Historically Designated: Yes / Tenant (� c)/lr f A. }( C.) l ? Owner's Address 3 o ( ON/6 ,Q p2 S ! Phone 7 s ' 14 ?SZ) Contracting Co. '" V c Address Qualifier SS# Phone State # Municipal # Competency # Ins. Co. Architect/Engineer � Address Bonding Company ' Address Mortgagor Address Permit Type (circle one): BUILDIN ELECTRICAL PLUMBING MECHANICAL ROOFING PAVING FENCE SIGN WORK DESCRIPTION Wal Sj c k V 1 -A Square Ft. - PERMIT APPLICATION FOR MIAMI SHORES VILLAGE WARNING TO OWNER: YOU MUST RECORD A NOTICE OF COMMENCEMENT AND YOUR FAILURE TO DO SO MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY (IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.) Application is hereby made to obtain a permit to do work and installation as indicated above, and on the attached addendum (if applicable). I certify that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that separate permits are required for ELECTRICAL, PLUMBING, SIGNS, POOLS, ROOFING and MECHANICAL WORK. OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Furthermore, I authorize the above -named contractor t• do the work stated. 0 owner an • or Signature Not ., to O r er and/or C M Commission Expires: APPROVED: Zoning Mechanical ndo President FEES: PERMIT Yo RADON 620-F‘ o ' resident Date C ., Q FICIA NOTAR1 SEAL . i MAXINE YOSS NOTARY PUBLIC STATE OF FLORIDA COMMISSION NO. CC498967 MY COMMISSION EXP. OCT. 16,1999 C.C.F. . f0 NOTARY 32- -0(3- susv No Master Permit # e 01A&I & J c/- tdc44-1� Estimated Cost (value) goo -.— Notary as to ontractor ' Owner- Builder y Commission Expir OFFICIA NOTAR SEAL MAXINE YOSS NOTARY PUBLIC STATE OF FLORIDA COMMISSION NO. CC498967 MY COMMISSION EXP. OCT. 16,1999 TOTAL DUE ye. ,S"d Building 4 �� 4 1 /dt Electrical Plumbing Engineering 3750 N.W. 46th St. Miami, FL 33142 1901 N.W. 18th St. Bldg. D North Pompano Bch., FL 33069 June 11,1996 Frank Lubien Building Official 10050 NE 2 Street Miami Shores, FL 33138 Dear Mr. Lubien, We are the Dade County Notice of Acceptance Holder for the 20 Gage Galvanized Steel Storm Panel under number 95-0914.05. This letter authorizes George Souvigne to use our 20 Gage Galvanized Steel Storm Panels to be used at the following job: George Souvigne 301 NE 102 Street Miami Shores, FL 33138 Robert "C cero President INDUSTRIES, INC. AWNINGS BAHAMA SHUTTERS CARPORTS SCREEN ROOMS SUNROOMS PATIOS STORM PANELS INSULATED FLORIDA ROOMS FOLD -A -GARD ROLL -A -GARD TROPIC ROOMS Miami (305) 633 -9650 S. Broward /Dade (305) 944 -9213 Broward (305) 960 -0110 Palm Beach (407) 734 -4339 Fax (305) 634 -9060 METRO•DADE Seaview Industries, Inc. 3750 N.W. 46 Street Miami, Florida 33142 PRODUCT CONTROL NOTICE OF ACCEPTANCE Your application for Product Approval of: 20 ga. Galvanized Steel Storm Panels under Chapter 8 of the Metropolitan Dade County Code governing the use of Alternate Materials and Types of Construction, and completely described in the plans, specifications and calculations as submitted by: Applicant, along with Drawing No. 94 -133, Sheets 1 thru 3 of 3. (For listing, see Section 8 of this Notice of Acceptance) has been recommended for acceptance by the Building Code Compliance office to be used in Dade County, Florida under the specific conditions set forth on Page 2 et seq. and the Standard Conditions on Page 3. The approval shall be valid for a period of three years. The Office of Code Compliance reserves the right to secure this product or material at anytime from a jobsite or manufacturer's plant for quality control testing. If this product or material fails to perform in the approved manner, the Code Compliance Department may revoke, modify or suspend the use of such product or material immediately. The Building Code Compliance Department reserve the right to require retesting of this product or material should any amendments to the South Florida Building Code be enacted affecting this product or material. C/ ACCEPTANCE No.: 95- 0914.05 (Renews No.: 95-0406.06) Raul Rodriguez EXPIRES 11/09/98 Supervisor Product Control Division The expense of such testing will be incurred by the manufacturer. "PLEASE NOTE** THIS IS THE COVER SHEET. SEE ADDITIONAL PAGES FOR SPECIFIC AND GENERAL CONDITIONS BUILDING CODE COMMITTEE This application for Product Approval has been reviewed by the Metropolitan Dade County Building Code Compliance Department and approved by the Building Code Committee to used in conditions set forth above. (2/ Charles Danger, P.E. Director Building Code Compliance Dept. -1- Metropolitan Dade County APPROVED: NOV 0 g 1995 METROPOLITAN DADE COUNTY. FLORIDA METRO•DADE FLAGLER BUILDING BUILDING CODE COMPLIANCE OFFICE SUITE '603 METRO -CAOE FLAGLER BUILDING 140 WEST FLAGLER STREET MIAMI. FLORIDA 33130 -1563 (305) 375.2901 FAX (305) 375 -2908 PRODUCT CONTROL SECTION (305) 375 -2902 FAX (305) 372.6339 Seaview Industries, Inc, ACCEPTANCE NO.: 95- 0914.05 APPROVED November 9. 1995 EXPIRES : November 9. 1998 NOTICE OF ACCEPTANCE: SPECIFIC CONDITIONS 1. DESCRIPTION 1.1 This approves a 20 ga. steel storm panel designed to comply with the South Florida Building Code, 1994 Edition for Dade County, for the locations where the pressure requirements as determined by ASCE 7 -88 "Minimum Design Loads for Buildings and Other Structures ", do not exceed the Design Pressure Rating values in Section 7 and within the limitations contained in Section 3. 2. MATERIAL CHARACTERISTICS 2.1. 2.3 2.4 The storm panels shall be constructed as indicated on approved drawing No. 95 -133, Sheet 1 of 3, using 20 ga. (.035 ") steel, Structural Quality, Grade D, conforming to ASTM A446 (Fy = 50 ksi. min.). Galvanized with a minimun G90 coating. Panels are rolled formed, have a nominal width of 12.00" and a total width of 13.875 ", forming 2" deep ribs Components shall be aluminum alloys 6063 -T6, "h" header, "u" header, 2" x 2" x 1/8" angle, and a 1/8" thick x 2.25" x 3" (4" or 5.25 ") angle depending on built - out condition. Tested specimen: Dimensions: 49.5" wide x 83.5" long, 49.5" wide x 88" long, 37.5" wide x 136" long and 37.5" wide x 48" long overall. 3. LIMITATIONS 3.1 The design will be dependent on the maximum panel height of 7'-4" or 88 ", for wall and built out mount, 7' - 0" or 84" for ceiling/inside mount and to be installed only as outlined on drawing No. 95 -133 Sheets 1, 2 and 3 of 3. 3.2 Minimum separation to existing glass to protect shall be 2 5/8 ". 3.3 Maximum clearance between top of panel and inside of header shall be 1/4 ". 3.4 Special Requirement: . All panels longer than 33" shall require reinforcing 1/4 " -20 x 1" sidewalk bolts and washered wingnuts spaced at 12" o. c. at midspan, at all overlaps. 4. INSTALLATION 4.1 The panels shall be installed only in the following condition: 4.1.1 Wall Mount (Direct Mount) The panels are secured at the head and sill, either directly to 1/2" x 7/8" Rawl Calk -in anchors embeded in the wall, spaced at 6" o.c., using 1/4 " -20 SS machine bolts and Key Hole Washers (Direct Mount); OR to an "h" Header (Part 2) at the head; and to a 2" x 2" x 1/8" studded Sill Angle (Part 6) or an Optional Angle (Part 4) at the sill, both of which are anchored to the wall, using the tension anchors as shown on Dwg. No. 95 -133, Sheet 3 of 3, Section H "Direct Mount" OR Sheet 2 of 3, Section A "Wall Mount ", bearing the Dade County Product Control approval stamp. 2 eetet - ,y44 5 Brian Trujillo Engineer I Product Control Division Seaview Industries. Inc. ACCEPTANCE NO.: 95- 0914.05 APPROVED : November 9. 1995 EXPIRES November 9. 1998 NOTICE Q_F ACCEPTANCE: SPECIFIC CONDITIONS 4.1.2 Buildout Mount The panels are secured to the "U" Header (Part 3) at the head, fastened using 1/4%20 machine bolt & nut spaced @ 12" o.c., to a 2 1/4" x 5 1/4" x 1/8" aluminum Angle (Part 5) used to provide the buildout, and which is anchored to the wall. This condition is repeated at the sill except that a 2" x 2" x 1/8" Studded Angle (Part 6) is used in lieu of the "h" header. The 2 1/4" x 5 1/4" x 1/8" angles are then anchored to the wall using the tension anchors as shown on Dwg. No. 95 -133, Sheet 2 of 3, Sections D and G "Build -Out Mount ", bearing the Dade County Product Control approval stamp. 4.1.3 Ceiling/Inside Mount The panels are secured inside a top track "U" Header at the head, which is anchored to the inside of the opening; and fastened at the sill, to the 2" x 2" x 1/8" continuous aluminum Studded Angle (Part 6), using 1/4 " -20 studs with washered wingnut spaced at 6" o.c., which is anchored to a concrete slab or bulkhead, as shown on Dwg. No. 95 -133, Sheet 2 of 3, Section C "Ceiling/Inside Mount ", bearing the Dade County Product Control approval stamp. 4.1.4 Arty combination of the above, 4.2 Anchorage of the aluminum angles shall be to concrete, masonry and/or wood framing and shall consist of only the anchors, embedment and spacing specified on Drawing No. 95 -133, Sheets 1, 2 and 3 of 3. Substitution of anchor type or indicated embedment is unacceptable and requires to be engineered separately. Fasteners must have their own Notice of Acceptance. 4.3 Permanent set fastener components, embedded anchor bolts, threaded cones or metal shields, not in use, must be protected against corrosion, contamination and damage at all time. 5. IDENTIFICATION 5.1 Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Dade County Product Control Approved ". 5.2 Also a Warning Not shall be permanently stamped in each panel advising the home owner or tenant that the storm panels will not offer hurricane protection unless all reinforcing bolts are properly installed. 6. USE 6.1 Application for building permit shall be accompanied by two copies of the following: 6.1.1 This Notice of Acceptance. 6.1.2 Completely dimensioned drawing showing size and location, including height above grade, of openings to receive shutters; mean roof height, length and width of building. 6.1.3 Duplicate prints of approved drawings No. 95 -133, Sheets 1, 2 and 3 of 3, bearing the approval stamp, Notice of Acceptance number and date by Dade County Product Control Section, clearly marked to show the components selected for the proposed installation. 6.2 The Building Official shall ensure the adequacy of shutter to meet the pressure requirement of the opening in which it is to be installed. 6.3 This document renews Notice of Acceptance No. 95- 0406.06 ex ired 11/9/95. Brian Trujillo Engineer I Product Control Division TEST TEST LOAD DESIGN LOAD Deflection LARGE MISSILE IMPACT TEST SFBC PA 201 -94 88" Span 136" Span SATISFACTORY CTC -95 -007 Max.. 2 5/8" 2 7/8" CYCLIC WIND PRESSURE TEST SFBC PA 203 -94 POSITIVE +169.0 PSF CTC -95 -007 +130.0 PSF CTC -95 -007 CYCLIC WIND PRESSURE TEST SFBC PA 203 -94 NEGATIVE -130.0 PSF CTC -95 -007 -100.0 PSF CTC -95 -007 UNIFORM STATIC AIR PRESSURE TEST SFBC PA 202 -94 POSITIVE +208.0 PSF CTC -95 -007 +138.7 PSF CTC -95 -007 i Design 1.01" UNIFORM STATIC AIR PRESSURE TEST SFBC PA 202 -94 NEGATIVE -187.2 PSF CTC -95 -007 -124.8 PSF CTC -95 -007 DESIGN PRESSURE RATING +130.0 PSF - 100.0PSF Seaview Industries. Inc, ACCEPTANCE NO.: 95- 0914.05 -2b- APPROVED : - November 9. 1995 EXPIRES : November 9. 1998 NOTICE OF ACCEPTANCE: SPECIFIC CONDITIONS 7. TESTS PERFORMED TESTS: RESULTS: 8. EVIDENCE SUBMITTED 8.1 Tests: 8.1.1 Test report on: 1. Uniform Static Air Pressure Test per PA 202 -94 2. Large Missile Impact Test per PA 201 -94 and 3. Cyclic Wind Pressure Test per PA 203 -94 of galvanized 20 ga. steel storm panels, prepared by Construction Testing Corporation, Report No. CTC -95 -007, dated March 30, 1995, signed and sealed by Christopher G. Tyson, P.E. 8.2 Drawing: 8.2.1 Drawing No. 94 -133, 20 ga. Steel Storm Panel, Sheets 1, 2 and 3 of 3, prepared by Knezevich & Associates, Inc., dated 05/20/95, revised on 5/24/95, signed and sealed by V.J. Knezevich, P.E. 8.3 Material certification: 8.3.1 Mill Certified Inspection Report issued by R &R Metals Inc. , , dated 2/20/95 for Hot -Dip Zinc - Coated Edge Sheet Coils of Galvanized Steel, Structural Quality, Grade D,with a minimum Fy=50 ksi. 8.3.2 Certified Tensile Test Report issued by QCM, Q C Metallurgical, Inc. Report Number 5Cm -706, dated March 30, 1995 for sample #CTC 95 -007, tested per ASTM E8 -93, signed and sealed by Frank Grate, P.E. 8.4 Calculations: 8.4.1 Anchor analysis dated 5/22/95, 2 pages, prepared by Knezevich & Associates, Inc, signed and sealed by V.J. Knezevich, P.E. /J 4;ei eG k it GliQi 9rrian Truji o Engineer I Product Control Division Seaview Industries. Inc. ACCEPTANCE NO. : 95-0914.05 APPROVED . November 9. 1995 EXPIRES : November 9. 1994 NOTICE OF ACCEPTANCE: STANDARD CONDITIONS Renewal of this Acceptance (approval) shall be considered after a renewal application has been filed and the original submitted documents, including test supporting data, engineering documents, are no older than eight (8) years. Anv and all approved products shall be permanently labeled with the manufacturer's name, city, state, and the following statement: "Dade County Product Control Approval ", or as specifically stated in the specific conditions of this Acceptance. 3. Renewals of Acceptance will not be considered if: a) There has been a change in the South Florida Building Code affecting the evaluation of this product and the product is not in compliance with the code changes; b) The product is no longer the same product (identical) as the one originally approved; c) If the Acceptance holder has not complied with all the requirements of this acceptance, including the correct installation of the product; d) The engineer who originally prepared, signed and sealed the required documentation initially submitted, is no longer practicing the engineering profession. 4. Any revision or change in the materials, use, and/or manufacture of the product or process shall automatically be cause for termination of this Acceptance, unless prior written approval has been requested (through the filing of a revision application with appropriate fee) and granted by this office. 5. Any of the following shall also be grounds for removal of this Acceptance: a) Unsatisfactory performance of this product or process; b) Misuse of this Acceptance as an endorsement of any product, for sales, advertising or any other purposes. 6. The Notice of Acceptance number preceded by the words Dade County, Florida. and followed by the expiration date may be displayed in advertising literature. If any portion of the Notice of Acceptance is displayed, then it shall be done in its entirety. 7. A copy of this Acceptance as well as approved drawings and other documents, where it applies. shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at all time. The copies need not be resealed by the engineer. 3. Failure to comply with any section of this Acceptance shall be cause for termination and removal of Acceptance. 9. This Acceptance contains pages 1, 2, 2(a) through 2(b) and this last page 3. Items 10. 11 & 12 listed below only apply to glazed products and doors 10. Unless specifically indicated in the Acceptance (approval), this unit is approved as a single unit installation. For multiple installation of this unit, a separate Acceptance for mullions is required from the Product Control Section. 11. The spacing of fasteners at window sills shall be as tested. The spacing of fasteners in all other parts of the frame, shall be as tested, but in no case shall exceed 24" on center. The first fastener shall be located at a maximum of 6" from each corner and mullion or stile. Fastener shall fully penetrate the buck. which shall be the same size as the one tested with the unit. No wood or plastic shields or pins shall be used for anchoring. See section four (4) of this approval for sizes of fasteners used in testing. 12. Hardware for all windows and doors shall conform to Security and Forced Entry Prevention, Chapter 36 of the South Florida Building Code. ^ ' END OF THIS ACCEPTANCE Brian Trujillo, Engineer 1 Product Control Division