Loading...
RCRT-10-942BUILDING PERMIT APPLICATION FBC 20 Permit Type: BUILDING RO _F NG Owner's Name (Fee Simp - itle AU 1 Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 INSPECTION'S PHONE NUMBER: (305) 762.4949 r Permit No.4`� -f 1O " c Master Permit No. ho der) i A litC . ii one # _�1� Owner's Address City State Zip Tenant/Lessee Name Phone # cf - 3D q 15 Email TA2A (1'1U20 C LL Job Address (where the work is being done) 1 0 NE 105 si ( NO i J C6% i City Miami Shores Villa e County Miami -Dade Zip FOLIO / PARCEL # It 2 C 2:101 '3( Is Building Historically Designated YES NO Flood Zone Contractor's Company Name Phone # Contractor's Address City State Zip Qualifier Name Phone # State Certificate or Registration No. Certificate of Competency No. Contact Phone Architect/Engineer's Name (if applicable) Phone # ❑Alteration E -mail Value of Work For this Permit $ Square / Linear Footage Of Work: 1 4 Type of Work: ['Addition Describe Work: ❑New ❑ Repair/Replace ❑ Demolition *************************************** 1es ************ * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** d c7 Submittal Fee $ Permit Fee $ CCF $ CO /CC $ Notary $ Scanning $ Radon $ Double Fee $ Structural Review. $ Training/Education Fee $ DPBR $ Violation date: Total Fee Now Due $ Technology Fee $ Bond $ See Reverse side - Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature Signature Owner or Agent Contractor The foregoing instrument was acknowledged before me this The foregoing instrument was acknowledged before me this day of ,20 , day of ,20,by who is personally known to me or who has produced who is personally known to me or who has produced As identification and who did take an oath. as identification and who did take an oath. NOTARY PUBLIC: NOTARY PUBLIC: Sign: Sign: Print: Print: My Commission Expires: My Commission Expires: APPROVED BY (Revised 07 /10 /07)(Revised 06/10/2009) Plans Examiner Zoning Engineer Clerk checked UNITED STATES POSTAL SERVICE • Sender. Please print your name, address, and ZIP +4 in this box • MIAMI SHORES VILLAGE 10050 N. E. 2nd AVE. MlogamPm4Fukame SENDER: COMPLETE THIS SECTION • Complete items 1, 2, and 3. Also complete Rem 4 if Restricted Delivery is desired. • Print your name and address on the reverse so that we can retum the card to you. • Attach this card to the back of the mailpiece, or on the front if space permits. 1. Article Addressed to: HOLtDAI INVESTMENT COP-P. 131(0 NE 105 SE MtA& % ORES, FL 33138 10 - 2. Article Number (rfansfer from service label) 1141 111141 /1111'1IC1t17aIIlh'Il liit}11 Ill'thbdt A. icnature B. R -. ` Wed by ( Ps Form 3$11 Feb 2004 Domestic Ijetum Receipt B F Y. y ( ( �� s1 F F124 dii I [ f£ 61f[ Y COMPLETE THIS SECTION ON DELIVERY First -Class Mail Postage & Fees Paid LISPS Permit No. G -10 D. Is delivery :. dry different from item 1? ❑ Y If YES, enter delivery address Mow: ❑ No 7009 1410 0000 7000 9781 ❑ Agent ❑ Addressee 3. Service Type ❑ Certified Man ❑ Express Man ❑ Registered 0 Retum Receipt for Merchandise ❑ Insured Man ❑ C.O.D. 4. Restricted Delivery? (Extra Fee) ❑ Yes 102596.02 -M -1540 U.S. Postal ServiceT CERTIFIED MAIL, RECEIPT (Domestic Mail Only; No Insurance Coverage Provided) For delivery information visit our website at www.usps.com© Postage Certified Fee Return Receipt Fee (Endorsement Required) Restricted Delivery Fee (Endorsement Required) Total Postage & Fees Postmark Here Sent To or PO Box No. 1311p WE. 105 s1 . Cfty, Stete, ZIP+4 5• PS Form 3800, August 2006 See Reverse for Instructions Certified Mali Provides: A malting receipt ® A unique Identifier for your mailpiece ® A record of delivery kept by the Postal Service for two years Important Reminders: ® Certified Mali may ONLY be combined with First -Class Mails or Priority Mail®. ✓ Certified Mail is not available for any class of international mall. is NO INSURANCE COVERAGE IS PROVIDED with Certified Mail. For valuables, please consider Insured or Registered Mail. c For an additional fee a Return Receipt may be requested to provide proof of delivery. To obtain Return Receipt service please complete and attach a Retum Receipt (PS Form 3811) to the article and add applicable postage to cover the fee. Endorse mallpiece Return Receipt Requested°. To receive a fee waiter for a duplicate return receipt, a USPSs postmark on your Certified Mal( receipt is required. a For an additional fee, delivery may be restricted to the addressee or addressee's authorized agent. Advise the clerk or mark the mailpiece with the endorsement 'RestrictedDelivery°. a If a postmark on the Certified Mail receipt is desired, please present the arti- cle at the post office for postmarking. If a postmark on the Certified Mall receipt is not needed, detach and affix label with postage and mail. IMPORTANT: Save this receipt and present It when making an inquiry. PS Form 3800, August 2008 (Reverse) PSN 7530 -02- 000.8047 5/28/2010 MIAMI SHORES VILLAGE Building Department Certified Mail # 7009 1410 0000 7000 9781 Property located at: Address: 1316 NE 105 Street Miami Shores, Florida, 33138 Permit Number: RCRT - 5 - 10 - 942 Folio # Dear Owner: Sincerely, Norman Bruhn, Building Official 305- 795 -2204 10050 NE 2 Ave, Miami Shores Fl, 33138 Tel: 305- 795 -2204• Fax: 305- 756 -8972 Notice of Required Inspection/Certification The Village has been notified by Metro -Dade Building & Zoning Department that the above referenced property has a building or structure that is forty (40) years old or older. In accordance with Miami -Dade County Chapter 8 Section 8 -11, the subject property must be inspected by a Florida Registered Architect or Engineer and a report furnished to this office. A report and a fee of two - hundred fifty dollars must be submitted to this office within ninety (90) days of receiving this Notice of Required Inspection/Certification. If you would like a copy of Minimum Inspection Procedural Guidelines for Structural and Electrical Recertification, or if you have any questions, please call my office at 305- 795 -2204. Holiday Investment Corporation 1510 NE 105 Street Miami Shores, Florida 33138 August 2, 2010 Miami Shores Village Building Department 10050 NE 2nd Avenue Miami Shores, Florida 33138 Re: Permit Number: RCRT -5 -10 -942 Notice of Required Inspection/Certification Holiday Investment Corporation — Apartments 1316 NE 105 Street, Miami Shores, F133138 Dear Sirs: Pursuant to our May 28, 2010 Notice requiring a 40 -Year Recertification of the above - listed property, attached please find the required Engineering Reports prepared by GNP Engineering Group, Inc. along with our check #1493, in the amount of $250.00 made payable to Miami Shores Village. If you have any other questions, please let us know. Thank you, Donald Murray Enclosure: Report and Check JUL 2 6 2010 5/28/2010 MIAMI SHORES VILLAGE Building Department -Ceiiified Mail # 7009 1410 0000 7000 9781 Property located at: Address: 1316 NE 105 Street Miami Shores, Florida, 33138 Permit Number. RCRT -5-10 -942 Folio # Dear Owner: Sincerely, Norman Bruhn, Building Official 305- 795 -2204 10050 NE 2 Ave, Miami Shores Fl, 33138 Tel: 305- 795 -2204- Fax: 305- 756 -8972 Notice of Required Insnection/Certification The Village has been notified by Metro-Dade Building & Zoning Department that the above referenced property has a building or structure that is forty (40) years old or older. In accordance with Miami -Dade County Chapter 8 Section 8 -11, the subject property must be inspected by a Florida Registered Architect or Engineer and a report furnished to this office. A report and a fee of two- hundred fifty dollars must be submitted to this office within ninety (90) days of receiving this Notice of Required Inspection/Certification. If you would like a copy of Minimum. Inspection Procedural -Guidelines for Structural and Electrical Recertification, or if you have any questions, please call my office at 305- 795 -2204. • • • BUILDING RECERTIFICATION INSPECTION REPORT G PREPARED FOR: HOLIDAY INVESTMENT CORP. PROPERTY LOCATED AT: 1316 NE 105 STREET MIAMI SHORES, FLORIDA N P engineering group, inc. PREPARED BY: 10400 NW 33' Street, Suite 220, Doral, Florida 33172 TELEPHONE: (305) 592 -4538 / FAX: (305) 592 -1433 • • • July 7, 2010 Holiday Investment Corp. 1510 NE 105 Street Miami Shores, FL 33138 RE: 40 -Year Recertification of Building Located at 1316 NE 105 Street Dear Building Official: In accordance with Section 8 -11(f) of the Code of Miami -Dade County, GNP Engineering Group, Inc. has performed an inspection of the building located at 1316 NE 105 Street and determined the building to be structurally and electrically safe for continued use under present occupancy. The findings of our inspection are summarized in this written report that follows the Minimum Inspection Procedural Guidelines for Building Recertification and is accompanied by a set of photos depicting the condition of the building. This report does not preclude the building from subsequent inspections as deemed necessary by the Building Official. As a routine matter, in order to avoid possible misunderstanding, nothing in this report should be construed directly or indirectly as a guarantee for any portion of the structure. To the best of our knowledge and ability, this report represents an accurate appraisal of the present condition of the building based upon careful evaluation of observed conditions, to the extent possible. Should you have any questions concerning this report, please feel free to contact us at (305) 592 -4538. Sincerely, GNP Engineering Gro Attachments: Structural Report Electrical Report Photos cc: File engineering group, inc. ?o GOFv `' ,��GENSF'° �c� • : - �: Benny ' Gonzalez, P.E - No. 50746 President : . STATE FL. uc. No. 50746 OA • P i. 01:1,1 ‘0,•\% ` +" iiiiitt E Angel Paredes, PF,� ; STA Vice - President ; FL. Lic. No. 44096 '0, Vt9r; I I OW 10400 N.W. 33rd Street, Suite 220 ❑ Doral, Florida 33172 Ili Tel.: 305 -592 -4538 ® Fax: 305 -592 -1433 II • Civil Engineering ® Structural Engineering II Construction Management • Infrastructure Assessment IS Database Management 11 1,, Fp i ' ., NS.FS • • 096 • Data Cols * OF 147 P � 110s % • 40 -Year Recertification ® Due Diligence • • j. General Description: Two -story building, CBS construction, 7,459 SF (refer to • PART A - STRUCTURAL 1. DESCRIPTION OF STRUCTURE a. Name of Title: Holiday Investment Corp. b. Street Address: 1316 NE 105 St., Miami Shores, Florida c. Legal Description: Holiday Investment Corp. d. Owner's Name: Holiday Investment Corp. e. Owner's Mailing Address: 1510 NE 105 St., Miami Shores, FL 33138 -2116 f. Building Official Folio Number: 11- 2232 - 027 -0150 g. Year Built: 1960 h. Building Code Occupancy Classification: Group R Occupancy i. Present Use: Residential Photos). k. Nature of Present Loading: Eight (8) living units. 1. Additions to Original Structure: None visible. 2. INSPECTIONS: a. Date of Notice of Required Inspection: May 28, 2010 b. Date of Actual Inspection: June 30, 2010 c. Name and Qualification of Individual Submitting Inspection p t. E . ii. Angel S. Paredes, P.E. (License #44096) $. , 4096 ' s -,''�F'. ORIOP•�\ . idNAC 04 ,, ■∎`• '11,,,,It 'ti�` Angel S. Paredes PE #44096 Page S -1 of 7 GNP Engineering Group, Inc. INSPECTION REPORT d. Description of Any Laboratory or Other Formal Testing: Not required; used manual and visual inspection procedures. e. Accessibility for Inspection: Building was accessible at time of inspection. • • 3. REPAIRS: a. Structural Repair: [ X ] None Required [N /A] Required / Description b. Comments: This report is solely for the purposes of the 40 -Year Recertification based on the "Minimum Inspection Procedural Guidelines" and not for purposes of reporting for a purchase transaction. Any future potential buyers are responsible for obtaining their own independent inspection. This report shall not be used to cause action in favor of a third party against either the current Owner or GNP Engineering Group, Inc. (GNP). Services rendered by GNP are in accordance with the contractual agreement between GNP and the current Owner. This report is only intended to identify structural deficiencies and to recommend that repairs be made to the structure, if needed. This report is not intended to identify means and methods of repair, nor is this report to be construed as a design document to be used for permitting and construction. If required, the Owner will be responsible for obtaining the services of a Registered Professional Engineer, or "Design Engineer ", to design any remedial work required to repair the structural deficiencies as identified in this report. In addition, the Owner will be responsible for obtaining the necessary permits for construction and for having a licensed Contractor perform the work in accordance with the requirements of the Florida Building Code. 4. SUPPORTING DATA a. 6 Sheets of Written Data (Part A) b. 2 Photographs (Part A & Part B) Page S -2 of 7 , �00 11II I,,,�� �% ' 9 p A�� . , F °® • N , 44096 ° 7. V Y/1 � � E OF . ,'' ONAL E t 1g $it Angel S. Paredes PE #44096 • GNP Enginee Group Inc. INSPECTION REPORT c. N/A Drawing (Plan) 5. PRESENT CONDITION OF STRUCTURE a. General Alignment: Good condition. [N /A] Bulging - None observed during inspection. [N /A] Settlement - None observed during inspection. [N /A] Deflection - None observed during inspection. [N /A] Expansion - No expansion above normal observed during inspection. [N /A] Contraction - No contraction above normal observed during inspection. b. Portions Showing Distress: None visible. c. Surface Conditions: Good condition. d. Cracks: Hairline sized stucco cracks visible. e. General Extent of Deterioration: No significant deterioration of structure observed. f. Previous Patching or Repairs: None visible. 6. MASONRY BEARING WALLS a. Concrete Masonry Units: Good condition. b. Reinforced Concrete Tie Columns: Good condition. c. Reinforced Concrete Tie Beams: Good condition. d. Lintels: Good e. Other Type Bond Beams: N/A Page S -3 of 7 PARd • Angel S. Paredes PE #44096 • • • GNP En Groi Inc. INSPECTION REPORT f. Masonry Finishes (Exterior): 1) Stucco — Good condition. 2) Veneer — N/A 3) Paint - Good condition. 4) Other - N/A h. Masonry Finishes (Interior): 1) Vapor Barrier - N/A 2) Furring & Plaster — Good condition. 3) Paneling —N/A 4) Paint — Good condition. 5) Other - N/A Cracks: 1) Location — N/A 2) Description - N/A j. Spalling: 1) Location — N/A 2) Description - N/A k. Rebar Corrosion: [ X ] None Visible [N /A] Minor (patching will suffice) [N /A] Significant (but patching will suffice) Page S -4 of 7 Angel S. Paredes PE #44096 • G ' En•ine -rii rou REPS 'T [N /A] Significant (structural repairs required) / Description 7. FLOOR & ROOF SYSTEMS a. Roof System: 1) Description — The building has a flat roof with fiberglass roofing surface and roof framing system consisting of wood joists. 2) Heavy Equipment and Condition of Supports — HVAC equipment supports observed to be secure and in good condition. 3) Types of Drains /Scuppers and Condition — Scuppers observed to be in good condition. 4) General Condition - The roof surface was observed to be in fair condition. There were no visible signs of water intrusion observed in the building. b. Floor System: Floor system consists of concrete slab on grade for first floor and wood joists for second floor. Floor coverings, furniture and stored materials prohibited a visual inspection of the entire floor surface. However, the visible areas of the floor system were observed to be in good condition. c. Concealed Spaces Opened for Inspection: No attic space. 8. STEEL FRAMING SYSTEMS a. Description: Square steel columns. b. Exposed Steel: Paint observed to be in good condition with no corrosion visible. c. Concrete or Other Fireproofing: N/A d. Elevator Sheave Beams & Connections, and Machine e. Concealed Spaces Opened for Inspection: N/A f. General Condition: Good condition. Page S -5 of 7 1411Th,,, Floor Beams ] , PARF,�'., �� . ��GE Ns • s ;, ® No 40 6 r � %b;.. & % � ST Angel S. Paredes PE #44096 GNP Engineering GI Loup, Inc. INSPECTION REPORT 9. CONCRETE FRAMING SYSTEMS a. Description: CBS construction with reinforced concrete columns and beams. b. Cracking/Spalling: [ X ] Not Significant [N /A] Location and Description of Members Affected and Type c. General Condition: Good condition; no structural deficiencies were observed. d. Rebar Corrosion: [ X ] None Visible [N /A] Location and Description of Members Affected [N /A] Significant (but patching will suffice) [N /A] Significant (structural repairs required) e. Samples Chipped Out in Small Areas: [X ] No [N /A] Yes / Description f. Concealed Spaces Opened for Inspection: N/A 10. WINDOWS a. Type: Aluminum frame, jalousie and awning type windows. 00 , 11111,, 0 %, ... PARE , 1, ' b. Anchorage: Screws observed to be in good condition. .,, l , o o ' o o - . ' ; ` . GENS. ,' e c. Sealants: Good condition. No. 44`x' :14./ ' SS I O N AV. 0 Angel S. P PE #44096 Page S -6 of 7 • • GNP Engineeri g Group, Inc. d. Interior Seals: Good condition. e. General Condition: Good condition. 11. WOOD FRAMING a. Type: Wood joists for roof and second floor framing. b. Metal Fittings: Not visible. c. Joints: Not visible. d. Drainage: No accumulation of moisture observed on ceiling finishes. e. Ventilation: Vent screens along soffits. f. Concealed Spaces Opened for Inspection: No attic space. Page S -7 of 7 INSPECTION REPORT .1llflf s ��.•�� No i "I " Angel S. Paredes PE #44096 GNP Engineering Group, Inc. INSPECTION REPORT • PART B - ELECTRICAL • • 1. DESCRIPTION OF STRUCTURE a. Name of Title: Holiday Investment Corp. b. Street Address: 1316 NE 105 St., Miami Shores, Florida c. Legal Description: Holiday Investment Corp. d. Owner's Name: Holiday Investment Corp. e. Owner's Mailing Address: 1510 NE 105 St., Miami Shores, FL 33138 -2116 f. Building Official Folio Number: 11- 2232 - 027 -0150 g. Year Built: 1960 h. Building Code Occupancy Classification: Group R Occupancy i. Present Use: Residential j. General Description: Two -story building, CBS construction, 7,459 SF (refer to Photos). k. Nature of Present Loading: Eight (8) living units. 1. Additions to Original Structure: None visible. 2. INSPECTIONS: a. Date of Notice of Required Inspection: May 28, 2010 b. Date of Actual Inspection: June 30, 2010 Page E -1 of 7 S . m - T E pF �� O,c oR\,, SStO NP\ - - Benny P. Gonzalez PE #50746 • GNP Engineering Group, Inc. INSPECTION REPORT c. Name and Qualification of Individual Submitting Inspection Report: Benny P. Gonzalez, P.E. (License #50746) d. Description of Any Laboratory or Other Formal Testing: Not required; used manual and visual inspection procedures. e. Accessibility for Inspection: Building was accessible at time of inspection. 3. REPAIRS: a. Electrical Repair: [ X ] None Required [N /A] Required / Description b. Comments: This report is solely for the purposes of the 40 -Year Recertification based on the "Minimum Inspection Procedural Guidelines" and not for purposes of reporting for a purchase transaction. Any future potential buyers are responsible for obtaining their own independent inspection. This report shall not be used to cause action in favor of a third party against either the current Owner or GNP Engineering Group, Inc. (GNP). Services rendered by GNP are in accordance with the contractual agreement between GNP and the current Owner. This report is only intended to identify electrical deficiencies in the buildings and to recommend that repairs be made to the electrical system, if needed. This report is not intended to identify means and methods of repair, nor is this report to be construed as a design document to be used for permitting and construction. If required, the Owner will be responsible for obtaining the services of a Registered Professional Engineer, or "Design Engineer ", to design any remedial work required to repair the electrical deficiencies as identified in this report. In addition, the Owner will be responsible for obtaining the necessary permits for construction and for having a licensed Contractor perform the work in accordance with the requi I is of the .0%.( G O : ° No. 5074. / .5) '. - STAT OF �Q 3enny P. Gonzalez �0 P ° v� PE #50746 PageE -2of7 % .FS' � ..R � ° °° S /ONAL E� • GNP Engineering Group, Inc. Florida Building Code. 4. SUPPORTING DATA a. 6 Sheets of Written Data (Part B) b. 2 Photographs (Part A & Part B) c. N/A Drawing (Plan) 5. ELECTRIC SERVICE a. Estimated Size, Amperage: 600 Amps [ X ] Fuses [ ] Breakers b. Phase: [ ] Three Phase [ X ] Single Phase c. Condition: [ X ] Good [ ] Fair [ 1 Needs Repair d. Comments: Eight fuse disconnects of 100 amps for apartment units and a circuit • breaker panel (100 amps) for house power. 6. METER AND ELECTRIC ROOMS a. Clearances: [ X ] Good [ ] Fair [ ] Requires Correction b. Comments: No comments. 7. GUTTERS a. Location: [ X ] Good b. Tap & Fill: [ X ] Good c. Comments: No comments. Page E -3 of 7 [ ] Requires Repair INSPECTION REPORT 111 OI�Z [ ] Requires Repair 46 ems- STATE OF • �4./ �� OR\O 4111 -7 11111110 Benny P. Gonzalez PE #50746 GNP Engineering Group, Inc. 8. ELECTRICAL PANELS Panel #1 thru #8 a. Location: Apartment units #1 thru #8. b. Condition: [ X ] Good [ ] Requires Repair c. Comments: Circuit breaker panel in each unit. • 9. BRANCH CIRCUITS a. Identified: [ X ] Yes [ ] No, must be identified. b. Conductors: [ X ] Good c. Comments: No comments. 10. GROUNDING OF SERVICE a. Condition: [ X ] Good [ ] Requires Repair b. Comments: No comments. 11. GROUNDING OF EQUIPMENT a. Condition: [ X ] Good [ ] Requires Repair b. Comments: No comments. 12. SERVICE CONDUITS/RACEWAYS a. Condition: [ X ] Good [ ] Requires Repair b. Comments: No comments. [ Page E -4 of 7 INSPECTION REPORT ] Deteriorated [ ] Must Be Replaced ,lelles G0A ENS F 50746 STATE OF .74 /0/ ` /ONAL c� % ` Benny P. Gonzalez PE #50746 • • GNP Engineering rout, Inc INSPECTION REPORT 13. SERVICE CONDUCTORS & CABLES a. Condition: [ X ] Good b. Comments: No comments. 14. WIRING METHODS, CABLES & CONDITION a. Types: [ X ] Conduit Raceways: [ X ] Good [N /A] Conduit PVC: [N /A] NM Cable: [N /A] BX Cable: b. Comments: No comments. 15. FEEDER CONDUCTORS a. Condition: [ X ] Good b. Comments: No comments. 16. EMERGENCY LIGHTING (N /A) a. Condition: [ ] Good [ ] Good [ ] Good [ ] Good [ ] Requires Repair [ ] Requires Repair [ ] Requires Repair b. Comments: Emergency lighting is not required as per Section 31.2.9 of the NFPA Life Safety Code Handbook. 17. BUILDING EGRESS ILLUMINATION a. Condition: [ X ] Good Page E -5 `0 11111,,,, �r ress. pT •' GENS •• No. 5 ] Requires Repair ] Requires Repair 1 Requires Repair 1 Requires Repair [ X ] None None G ' P. Gonzalez ;����� PE #50746 • • • GNP Engineering Group, Inc. INSPECTION REPORT b. Comments: No comments. 18. FIRE ALARM SYSTEM (N /A) a. Condition: [ ] Good [ ] Requires Repair [ X] None b. Comments: Fire alarm system is not required since building does not have more than 11 dwelling units as per Section 31.3.4.1 of the NFPA Life Safety Code Handbook. 19. SMOKE DETECTORS a. Condition: [ X ] Good [ ] Requires Repair [ ] None b. Comments: Smoke detectors should be inspected periodically as part of routine building maintenance. 20. EXIT LIGHTS a. Condition: [ X] Good [ ] Requires Repair [ ] None b. Comments: Exit lights should be inspected periodically as part of routine building maintenance. 21. EMERGENCY GENERATOR (N /A) a. Condition: [ ] Good [ 1 Requires Repair [ X ] None b. Comments: N/A 22. WIRING IN OPEN OR UNDER COVER PARKING GARAGE AREAS a. Condition: [ X ] Good [ ] R Repair [ ] None �`� p .G0411/ , % �'. AT. O ; , Benny P. Gonzalez Page E -6 R . , \�• • PE #50746 1,11,10 GNP Engineering Group, Inc. INSPECTION REPORT b. Comments: No comments. 23. OPEN OR UNDERCOVER PARKING AREAS AND EGRESS ILLUNIINATION a. Condition: [ X ] Good b. Comments: No comments. 24. SWIMMING POOL WIRING (N /A) a. Condition: [ ] Good [ ] Requires Repair [ X ] None b. Comments: N/A 25. WIRING TO MECHANICAL EQUIPMENT a. Condition: [ X ] Good b. Comments: No comments. Page E -7 of 7 [ ] Requires Additional [ ] None ] Requires Repair [ ] None - 50746 _ 7k _ *= STATE OF Q `' � v` � Benny dciaalez PE #50746 GNP Engineering Group, Inc. 1316 NE 105 Street, Miami Shores, Florida 40 -Year Recertification