MC-05-72Mechanical Permit Miami Shores Village 10050 NE 2nd Avenue Phone: 305 - 795 -2204 Permit Number: MC2005 -72 Printed: 5/31/2005 Applicant: VILLAGE DEL MAR Owner: DEL MAR VILLAGE JOB ADDRESS: 1200 ST NE 105 Contractor MULLER FIRE PROT. INC Local Phone: 305 - 636 -9780 Parcel # 1122320270110 Legal Description: Signed: (INSPECTOR) Contractor's Address: 3200 NW 38 ST Page 1 of 1 Fees: Description Amount FEE2005 -6877 Building Fee $960.00 FEE2005 -6878 CCF $19.20 FEE2005 -6879 Training and Education Fee $6.40 FEE2005 -6880 Technology Fee $24.00 FEE2005 -6881 Scanning Fee $12.00 Total Fees: $1,021.60 Total Fees11,021.60 Total Receipts: $0.00 Permit Status: APPROVED Permit Expiration: 11/20/2005 Construction Value: $32,000.00 Work: FIRE SPRINKLER SYSTEM In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responisibility for all work done by either myself, my agent, servants or employes. Signed: (Contractor or Builder) BY: MIAMI SHORES VILLAGE BUILDING DEPARTMENT 305- 795 -2204 Building Inspection Request Date 4 00105 Type Insp'n tP tI Skritit iv+U 134 fitv Permit No NL WO5 Name \I 114 64.,L 14. Address 17. Company Phone # Inspection Date Approved Correction Re- Insp'n Fee 4a3 41 ist, MIAMI SHORES VILLAGE BUILDING DEPARTMENT 305 - 795 -2204 Building Inspection Request Date '11 O5 Type Insp'n dQ, lti1tel itu 2.4 I 3yi Vow Permit No. i `Z Name V %(j, )1 Address 1200 1•11-. \ OS ST Company Phone # r an I ( C Rt0 WAS • Inspection Date \01 105 Approved ❑ Correction ❑ Re- Insp'n Fee ❑ Approved Re-Insp'n Fee ,5 .--- - % MIAMI SHORES VILLAGE ' BUILDING DEPARTMENT 305-795-2204 Building Inspection Request !, Date C6 I ail 05 .., Type Insp'n FA Y,Ilv 4,,txrI 2.4 i 3vO FIN/ Permit No. h‘C- 1 005 - 1. 12- ,- Name \I Ilkk(t c)4, 14. Address 12-00 NE N(. ST Company Phone # 1 (9 SO ONIAS -- Inspection Date ek1p 1 lo 5 ri Correction Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 7952204 Fax: (305) 756.8972 BUILDING 2ECETWED Permit No. () COS — 7 2 PERMIT APPLICATION MAY 2 5 m5 M ster Permit No. 8P03 -/ r'/ FBC2001 - Permit Type (circle): Building Electrical Plumbing ( Mechanical Roofing Owner's Name (Fee Simple Titleholder) Phone # ....- Owner's Address City State a Zip Tenant/Lessee Name Phone # Job Address (where the work is being done) ,/ 2.0 /V U> M 5 City Miami Shores Village County Miami -Dade Is Building Historically Designated YES NO Contractor's Company Name Mu //e 1?/' W2 ld'lli . Phone # _3 OS —' 43 4 970'0 Contractor's Address 3 - 2- G✓ 3 I s City / /,,„.,.. /9 ' 7 ' 471 � State FL . Zip 3 3 / Qualifier /C ®a e e,...) air-e- l't/ State Certificate or Registration No. S /Z 6 /Od U Certificate of Competency No. Lcl Z-6 / e 0 c Architect/Engineer's Name (if applicable) Phone # $ Value of Work For this Perini ❑Alteration c8,11 Type of Work: ['Addition �^ Describe Work: /L+� �,P//ZO/�i/,(C� � ‘7 Submittal Fee $ Permit Fee $ Notary $ Total Fee Now Due $ (Continued on opposite side) Training/Education Fee $ Zip Square Footage Of Work: ❑ Repair/Replace ❑ Demolition , 6 0 CCF $ "1 .ao CO /CC •Lk (... Technology Fee $ 24 Lb Scanning $ Radon $ Zoning Bond $ Code Enforcement $ Structural Plan Review. $ Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all . applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature Signatur ( - -Owner or Agyt The foregoing instrument was acknowledged before me this The foregoing instrument was acknowledged before me this day of , 20 _ , by , day of 20W by p(1 11 c 1 o\ who is personally known to me or who has produced who ' sonally own to me or who has produced W chc 05/13/03 As identification and who did take an oath. NOTARY PUBLIC: NOTARY PUBLIC: Sign: Sign: Print: Print: •: �� ondedThn My Commission Expires: _ _ __ My Commiss •n ET es;.o oFF` =ticRondmR - ��.., a.;. as i •,Ti ation and who did take an oath. *********************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** * * * * * * * * * * * ** * **�* * *�* * * * ** * ** * * * * * * * * * * * * * * * * * ** APPLICATION APPROVED BY: ei�J Plans Examiner Engineer Zoning HYDRAULIC DATA: SH EET • • • • • •• .. • • • ••• • . DESIGN: MULLER FIRE PROTECTION INC LOCATION: 3200 N.W. 38 STREET MIAMI, FLORIDA 33142 PROJECT: AREA: DESIGN: HOSE ALLOWANCE: CONSTRUCTION: C- FACTOR: • • VILLAGE DEL MAR SE CORNER OF 105 ST. AND BISCAYNE BLVD. MIAMI SHORES, FLORIDA GROUND FLOOR PARKING - AREA 1 N.F.P.A. 13 INSIDE: 50 GPM OUTSIDE: 200 GPM DATE: MARCH 11, 2005 . . CONCRETE SLAB WITH CONCRETE BLOCK EXTERIOR AND INTERIOR MAIN DIVIDING WALLS. INTERIOR PARTITIONS TO BE METAL STUD AND DRYWALL WITH DRYWALL CEILINGS SYSTEM TYPE: WET SPRINKLER TYPE: TYCO EC -11 BRASS UPRIGHT EXTENDED COVERAGE 3 NPT 155 DEG K =11.2 TYCO EC -11 BRASS SIDEWALL EXTENDED COVERAGE 3 / NPT 155 DEG K =11.2 INSIDE: C =120 STEEL C =150 CPVC PLASTIC UNDERGROUND: C =140 DUCTILE IRON C =150 C -900 DR14 PLASTIC FLOW 'PEST: 65 PSI STATIC 45 PSI RESIDUAL @ 1700 GPM FLOW CALCULATION SUMMARY: 58.33 PSI @ 536.24 GPM CITY CONNECTION FIRE PUMP: N/A i • • • • L •• ..•• • . a 0 1 2 !1111■1i•USi1l0Rfasa 11111 OW R IINSIONINIONINIONIIIIIIM 11111I•e• SWOP MUM ai -s 11111•11•.01101111•111■1 /1171 'WORMS --- OIaaOOa I111111•• INNS • 0011-••- ala 1111711•• •000•011!a1a0011- ■11111/••1100si ■1111 ewes .1 01•/0001 aaala 0 ■ 11H 00••••••••• !.1 11111111•10•OOi■ I1I1i1tt•OOf%MINIUM aka VIM 111111011•u0 - ass•O- I1111/..R•0.1.0■aaaia 111111101$0 0- 11110aaaa00 • 11111 u•••A •••••• ••t•••1 ■ 111l$IU ■U0000i01 - -SI I= ■11111 •••• 11001■ 0sa.aa0 nlnl.r•�a��ts���aatali 1/1111••4 • 1 1111111, Zia■ laiC)!< GasMI istr NOM i 'wMrM M � OM r = _MO � isMIMI l 11111/ ll aaaala U = IS i WI MI s ow no if it ifMe MB rr rr rf�m=NMIMM/rssl�issl•��liM -�•� • li i _ 0r10irr0MMOOOa0aOwrr riMINMOM rWM ir MON �� s00i11r • iliiiiii iiiiitccmit�rrirsl�•��O101Es IMIam�_r1�r_i■�_i/MDWM M ��BMOM NI�MEMMEN MMEMN MINI MI NIMO �� �--! IIIIIIiiii• ii ilNINIsasal�rrrrliram rrrr�a0 .O/Orra1•mosa10rlimassOrNEMMin MRS mil 00r NMI MINE ~ _ i �1iOSw ■•== OM�MI �rrir�ll��rlrlswllr�� MIS =N MIN MIN SIM mow r �r .1r t ill' 11tiO010it•2iTs�� 111Ur•[a\O ^••I�C7" 17 a a as a rm�.o a10aa1 �i stmarz.au4ca g T Y'1TS000■ INIMIo som rrililaH��lMENEMMIN a n 1111►-1111[7ICapozTr1Sa�aa ilmmi �summowr/rr rrrr�i'Ms0rrss0riNM -mow- -� MINN UMW nIV ..4C■0113 .1 ML A!7 IN���ralOMwrr rrMr�rrrsl���sss`r�� -NM��� MB MINI I.. • ,1- 1;:s•COmentu.l:� WuMIWalrMUal !•wrrrrrrMIrrrr�•N�0Is0�s -� -r- / �• IIi••• ii=l MIMI �MIaM0�ar00ra0I�_a1r IMaINN 0«0MI �OMMOE∎000OS�O MINI IMO r��MUMMON I1I1I WI NI MI OM /1171 I1\■■M 1 � - � -_ - -i r /• CCO■■. 1^ rl�w/ �1��if�■■ 1 �wrr� / r �� 11s �- 11w1�s■ ISrlll�r� ■r wrrr r■IS � 1 = s a...�r�ar� - •.i�r,rlrsl��r�■ r���1�r11r�r111w10i wift• 1111) ■mil d 0! as /al•aalfalr�alat is0�1�11 •wi1■1�ilrlsr NA a�1a1i rs r1 NOM u1117 „ a• OOi�srimumiili��a1ImrO s mamga 1�0m••� ■111nw•c�i � rfa�� -�.... rrlrl���raa��0�s� I in: 7; - ._';taM m7 P1a� rlo:7-Ps=Imm1 �wrt r MO r r r r ll r r�if• / uhEY7C 0∎ 1 IOirsElP OSo_ MI Ns a1i ....�-w■OMrsM■rMSNMMxrrrrrasMB ■r 001OS1r•r�i�� MIN RIM IIII11■ ►1 ■3Q1kISU-- 'r"7Gr -1 0' "Ir-1. "►. rM�Ct • ". rr=rrrr•���a�r•ss���t��rarii ■1in■3.11 a11aP4.7s_l ►71��� NM rrrNM r•��ss sr'�r��iri i 11M8Va \•t it ■ /i4■OI1.r "aaOR�ssy r w rOr �!ialI. gi 11111 r0Mr r III= VIM um limo s NMI moll l• MIME MN MIN MIMIiVIM i i IIIII1111IIW I11GJG a �1Y�L ] LrtSJ _ � _ r _ r _ r _ � _ rMaifr_r__rr•�i�s�� -- �rMNMN- MIN MINI i � I � a � IMO OEM MIN i Iiiliii•L:�ii0 s S 00 . O. �a1a11f 0��a0a a100O0f1� 01!1<J� ~��lMIMI i 1ita 11 a % \•1ii;1•f�si�WIN la r al l� MI r M_ NM r MI NM MI r r �`�__ s - �� 1 ` 1 �������� Milo 1111111■■ 011.` IfaiII S�ai r � rrr�irrrrrMs rl sMAs�s MIN ��r�i_ill�li� I111111■■ 111�1Oissisi7 aA• rOS��r�r0rr00i OrrrONrEMMEN∎lir'"! MN MIN s��rr�ir NMI MIN MIS r� 1 1tI111�CC: 11��Ss:: ::�CC• •O1 t>i��rrr� rrOli �i�s �i�rMI=IOWr 11111% 1% Y��11��i�sisai/ i/ 01��rrlrrrrr0 .Or rr � i■ OENis0Or Moil �0�� iI1111t•••mm1mmm•moOl mf•B•o II•1rr0lmlu l•irrrtriml___•rr_t■mli ail 1!_l_�_�_�__ I IIIIIII•••IIIr 0INIR01 /aaa a1 a1 r so MINI la ra101a �__00�rrr�00a 00. 0M as �� 0r ISM Mal � OrO>r.�i r0i ssl� /III 1111111 0 1i01O�Qaiaa ∎1111 r�0ir0i 0s / Il 1111 ■■ � � � s.�... i ■r ■� Ii ■t, ■r ■i 11l■w 0111- r1■0111M 1r err MI 1wr■OMEMI IMO MINI MIN rM NMI llr MINI r MINI NMI NM: !NM lrNI MIN rl■■ MEI a 111111■■ sum limm 0 / NM MIN 1O ri>_ Immo mom sl OS r 0i 0mmo an Now r mg 001 NM mot s sm r��r_ --`� i MIN IIIIII1•1IIN�� ■01a113∎1110ar1a11IMM SMOama•s01rme SOSS��s- - '-- i0�ir�r IMMO MI NM MI iii! 1 1111•: isINl; iNIslnrsrl- i■ S10 isO0ir 0s Ir�iirrsir •i'�NM�NM����irNM lwi NMI i MIS iMINI MIS 111 11111• ■■ . rra ■al ao�rrra. i�1�>is�l���= =�r ... �aara�I�al�ir rl� alr >r � �•1�r1s110irrw�r ■/r���� afi �� i 0101 s i s � i A•OOOi1i � r 1/ MB 1a■ Mal UM MIN MIN aS 1.1a �r / 111110 .1.0OONINIaasa011a�1111.01aNEr0a IS MUM 1ai�r00a000i1�rrI1 ■lOMrrrrrrs�i'SI'== MOM = _���WM NONE MIN 1111111•••••10•1 0 0 101 ••••••= 1011101101001100000=1•001100 a�100•a�0r s • �M00aa10a11N11ara/0� aa a>>•10O.Oil- arEr�sla �� 11 III ■■■■ 0 01001 rr -O - MINIM 1r 0r r� �� ■ EMI 1r1 - II111/1■ MMM0rrr0•a0M 111111/111•000i01�ssa !>�iliarsl•i r./- MO MIr rrr i��� �r�� r_sur•ll11rr/�rs �•l rlllrr •111111•••••000•1 1 0 1010011030110 • 0 • 110M100 -- 0•••••1=1•0 Mil MO Oa MO MI IIIIiI1•• 0000 �O0101assMOs- r0r0- Mr1Mr1ii0100011r■rrrrrUOal•000i MN s ��1i11 --- 11i11 ■0.11000 01 <t� MOM sat•a ■a10O�!•M�0a 001 i0arr� 00r0101rr0a1�00s0r aa r0rr� �10r �ra1r1� MINE ri 1 181111 00 0* S IMM OsiirMI NEM OS IIIIMUMMMOM r EMIMNa1 •rrMIIIIIrsi000i0■INrsM■rOOiMIMIrBMri -- II1111110000000 %0l∎•1•--w- rrr lrr0.OrrrMIIMMOMO 0i- OOiO00s�ili� = ■irININI -/rrt IIll*111.000 000SisSSO. 0101■ i0i r•irr_�rrs*rrr- ��isssrWm A�r�� -mM 111111•• 10000NI il�iNI 00rrr= so r MI r rrMrr 0•�0rss/rO0SrOS0s ■11111.0.00000 ism aa0ra ma so at al 0O 0r ow 000 a1 r am r 000 r rraD at•mow 0r 0- 011 -it• 1r r1r0�•� _ _ 111811.••1110 1O OM III AI l �1�0ONS Oa r 0a r 000 um a 1. 01r aural aa�aa a■11l Irk IMO 0aa aal�i -- OIIIIIII/ 01OOOii MIN 00i> r�0irr_ r_rr to00O00i1r rr_ r_r_m_0s'�rs_0r�_r_�r•rst��s_S� i 1111 if II i s a am Oi a ammo mum al r m mum =I r r or 0001 r ENO Nun now Imo sum 00s mom or r1 00s ma mum mows Imo 011aMille IIIIIso!♦ Or r•qr 00.E a>• Emil a0• �0•� a>• 000A rf•.a0� 00r III 111.• ill , 0 0- ally al.0 a, rs� SIMS MGM rr.r •1111x••• 0101. 01x• sa t• li�i0as Ois■ OSOta> iOalalrrrl�rr rl0•s■ ��rlrmais ■1111 111■ 0aaaa•11a00la■ MOM NM 0000- MINI INN a0 r0r MIS alOraliimiaaOM simil •r ion rr OEM MINI SUM NMI MINN ~r - - Itl11111 00000000 00 rllr li�rrrr rMI OBra� r r� r � 0!- lrsrr MOP NM MEM 611MI OEM IMO MOM !NM 000 IMO 21101•10•0101•0 MOM OEM MI= 1101011 MIMI MINI somon momm 1111 10000 010101 Now soso a1•erno m -• a0� lir� mow am saw Nl , ono am man wpm Mow moms =IN mum! r mot saw Mow r NMI =Ma 111111101 1■/0 ■ii.0MMWNMNO =MaiNOrr=MoeMI iri *rrriiMN swrssOr�OrOr��Ori0000iOr MEN 11111 1110.- O - al WO MB 0� MO MO Ma �_r -- 0a• O r: a001 ~ - -MIME ••••• MIN Oi! �1■■1 • rIi • • a O s a tv A, % G.P.M. MULTIPLY SCALE BY j ' $} rws 7 d 9 10 . 11 12 /3 IIII MIMI= IIIIMen MIMMBMI srr INN MOM _ MOM __ MOM= MSS MN ___ - - --NM NM • so am iam rrrrrram mil anron a 'rt iamas - -I � - ---- rr 0�0N- rrrrrrrr "OMM Msrlr• 000Ia1 •••a a/rtt *r MI r r• r MOM NM �sl� MOs �r��r ~ M I 0ia■1s000Ora10010ar00Mr ••irrr/r =�sr - + - �riri- O -- --- MIN - 0OM1iIrri'Mrl11M01O1rrr/0i s NNW ��r- - - .a, - al.r r aM 0011 - ma t - � IIIMM -_ U• 1 ••r• O r MIN MOB00 • 1l - NMI -- MINIS mom 1iaNm0O ----MI s' -rrrr Or00ir OM MINN=I 0 MI r MI NMI MIN 0∎••r - -00a r- rr -- r r 10•20•01/0 0aa 0�0�00000 MINN MINIM IINSII MINI MIN OM as Mae Ns 0ONI a/00 001 -1-a0 a- 11rBala MI MIMI r r 0001--- r1 0000I - -r- MME MININ NMI NEr NM OM MOr - =0 =1r! MOMS= IM ■ rlrlswsssstr•rr a l. - — — a■ 1111 a1 r r a0 MB a* MD I••• IMO a,• ••aaa•0a a01 a as - - 0r -- - r aal MOM •1010 - -00 - 0 MIMI MN NMI 1111•1111•11 VMS MINI OM MIMI 0010�O�OOrr�� -�r rrsa�rsrsrlr MINI EMI - MOM rMIMI Minn UMW •• IrIn1• o• sin ■ ir•■ ■my1/1r11MI1111rr Ilia r>, --- • E M■ r. -.� . - �0• i• •�� . EMI s s � 0111•0 1�.� rl .... 1N MUM MOM �1r 14 N 1.85 M 5 * ** FIRENET * ** HYDRAULIC ANALYSIS OF A FIRE PROTECTION SPRINKM;$YS ;EM ; :„ : : VERSION 2.2 — JANUARY 1992 • • • • • .. • • • • • • . • • • ••. • . . DATE FOR THIS COMPUTER RUN = 03 -11 -05 — TIME = 04:32:55 ID FOR THIS COMPUTER RUN = PARKING GARAGE REMOTE.AREA.1. .. . • •• • . . . • • • • • INPUT DATA FILE NAME = A: \14UNTTPKG.DAT • • .. • • • • • .•• .• OUTPUT DATA FILE NAME = A: \14UNTPKG.OUT *********************************** * * * * * * * * * * * * * * * * * * * * * * * * * ** * * ** * * * * * * * * * * * ** SPRINKLER SYSTEM DATA SUMMARY * * * * * * * * * * * * * * ** *********************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** WATER SUPPLY CHARACTERISTICS: STATIC PRESSURE = 65 PSI RESIDUAL PRESSURE = 45 PSI RESIDUAL FLOW = 1700 GPM ELEVATION OF PRESSURE GAGE = 2 FT. FLOW REQUIREMENTS: OUTSIDE HOSE FLOW REQUIREMENT (AT SUPPLY) = 200 GPM INSIDE HOSE FLOW REQUIREMENT (AT LOCATION 7 ) = 50 GPM TOTAL SPRINKLER SYSTEM FLOW REQUIRED (BASE OF RISER) = 0 GPM SPRINKLER INFORMATION: MAXIMUM SPACING OF SPRINKLER HEADS = 14 FT. MAXIMUM SPACING OF BRANCH LINES = 14 FT. REQUIRED MINIMUM FLOW (PER SPRINKLER) = 30 GPM REQUIRED MINIMUM FLOW DENSITY = .15 GPM /SQ. FT. OTHER SPRINKLER SYSTEM DATA: DEFAULT VALUE FOR C— FACTOR = 120 NUMBER OF BOOSTER PUMPS = 0 SUMMARY OF SPRINKLER OPERATION: SPRINKLER CONSTANT = 11.2 LOCATION OF OPERATING SPRINKLERS: 118 119 120 121 122 123 124 125 • • . .• • • • • •. . • . • • • • . • • • • • • • • • • • • • • • ••• • • • • • • • • • • • • • • • • • • •• ********************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** **************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** * * * * * * * * * * * * ** * * * * * * * * * * * * * ** PIPE DATA SUMMARY *********************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** NUMBER OF PIPES = 40 NUMBER OF JUNCTIONS = 37 3 5 4.070 150 110.0 31.7 0.0 5 6 4.260 120 4.0 10.0 4.0 6 7 4.260 120 4.0 10.0 0.0 7 8 4.260 120 10.0 10.0 9.0 8 9 4.260 120 2.0 0.0 1.0 9 10 4.260 120 3.0 10.0 0.0 10 11 4.260 120 17.7 0.0 15.7 11 12 4.260 120 16.7 0.0 14.7 8 100 2.635 120 4.5 19.0 0.0 100 101 2.635 120 20.0 0.0 0.0 101 102 2.635 120 19.0 12.0 0.0 102 103 2.635 120 20.0 0.0 0.0 101 104 2.635 120 11.0 12.0 0.0 104 105 2.635 120 30.0 36.0 0.0 105 106 2.154 120 51.0 12.0 0.0 104 107 2.154 120 60.0 70.0 0.0 106 107 2.154 120 20.0 15.0 0.0 108 109 2.154 120 20.0 15.0 0.0 107 108 2.154 120 53.0 12.0 0.0 109 110 2.154 120 44.0 12.0 0.0 110 111 2.154 120 30.0 18.0 0.0 108 111 2.154 120 54.0 70.0 0.0 111 112 2.154 120 32.0 0.0 0.0 112 113 2.154 120 20.0 18.0 0.0 113 116 2.154 120 7.0 6.0 0.0 116 117 2.154 120 15.0 0.0 0.0 102 112 2.154 120 147.0 130.0 0.0 103 114 2.154 120 110.0 6.0 0.0 114 115 2.154 120 12.0 0.0 0.0 115 113 2.154 120 8.0 6.0 0.0 116 118 1.687 120 7.5 9.0 1.5 117 121 1.687 120 7.5 9.0 1.5 118 119 1.687 120 12.0 0.0 0.0 121 122 1.687 120 12.0 0.0 0.0 119 120 1.452 120 12.0 0.0 0.0 122 123 1.452 120 12.0 0.0 0.0 114 124 1.452 120 1.5 5.0 1.5 115 125 1.452 120 1.5 5.0 1.5 . • • • • • • • •• • • • • . • • • . • . . • • • • • • • • • • • • • • ••• • • • • • • . • • • • • • • • olio • oli • •.. • olio • •. • ••• NUMBER OF LOOPS = 4 • • •• • . • •. • • • •• • • . • • . . • • • • • • • • • • • • ••• • • • FROM TO DIAM. HW -C LENGTH EQ. LN. EL. DIFF. (IN.) (FT.) (FT.) •4F$'.4 • •• .•o .. 1 2 4.070 150 70.0 24.2 . .5. E 0 O ' ' ' ' ' '• 2 3 4.070 150 12.0 120.9 ..0.0 • • �• ••• ••: • • ••• • •• • ••• • • • • • • • • • • • • •• • • •• • • • • •• • • • • • • • • • • • • • • • • • • • • • • •. • • • ****** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** * * ** HYDRAULIC ANALYSIS WITH REQUIRED FLOW AT ri MQTg }EA• •* *•• ****************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * **! * *24 1*# *i *i *ii * *, • • • • • • * ** *SUMMARY OF SPRINKLER SYSTEM OPERATION * * ** * THE FOLLOWING SPRINKLERS ARE OPERATING LOCATION SPRINKLER K 118 11.20 119 11.20 120 11.20 121 11.20 122 11.20 123 11.20 124 11.20 125 11.20 NODES FLOW PIPE EQV. ELEVATION FLOW PRESSURE 9.50 35.10 9.82 9.50 32.67 8.51 9.50 31.24 7.78 9.50 33.73 9.07 9.50 31.38 7.85 9.50 30.00 7.17 9.50 46.51 17.24 9.50 45.68 16.63 • • • •• • • • • • •• • • ••• • • • • •• • • • • • • • • • • • • • • • • •• • • • • • • • •• • • • • ••• • • • • ••• THE TOTAL SPRINKLER FLOW DELIVERED = 286.29 GPM THE OUTSIDE HOSESTREAM FLOW OF 200 GPM OPERATES AT 62.63 PSI THE INSIDE HOSESTREAM FLOW OF 50 GPM OPERATES AT 50.03 PSI THE MINIMUM DENSITY PROVIDED BY THIS SYSTEM IS 0.153 CPM /SQ FT WATER SUPPLY CHARACTERISTICS LOCATION AT PIPE NO 1 STATIC PRESSURE = 65 PSI RESIDUAL PRESSURE = 45 PSI AT 1700 GPM OPERATING PRESSURE = 58.33 PSI AVAILABLE PRESSURE = 62.63 PSI AT 536.24 GPM ** EXCESSIVE (OR REQUIRED) SUPPLY PRESSURE = 4.3 PSI * * * * * * * ** ********************* xxx xx********* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** *********************************** * * * * * * * * * * * * * * * * * * *** * * * * * * * * ** * * * * * * * * * * ** SUMMARY OF HYDRAULIC CALCULATIONS * * * * * * * * * * * ** *********************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** H -W DIA. PSI/ ELEV. START END DIFF. • • ••• • • • ••• •• •• • • • • • •• • • • • • • • • • • • • • • ••• • • • • • • • • • • • • • .. • .. • • • FROM -TO (GPM) (FT.) FT -C- IN. 100 -,FT PSI. PSI. PSI. PSI. 1 2 336.2 70.0 24.2 150 4.07 24R i • .1.17.•'5(raf :64. 16• -0.12 2 3 336.2 12.0 120.9 150 4.07 2.1'7 '0.00 5w.�� 2.88 3 5 336.2 110.0 31.7 150 4.07 2.17 0.00 55.58 52.50 3.07 5 6 336.2 4.0 10.0 120 4.26 2.62.. 1. • 5; 2.10 6 7 336.2 4.0 10.0 120 4.26 2.61. :5040:, 50 0.37 7 8 286.2 10.0 10.0 120 4.26 1.95 : 3.4 d :50'44 45./4 4.29 8 9 0.0 2.0 0.0 120 4.26 0.06 b.43 . 45.74"'43!31 0.43 9 10 0.0 3.0 10.0 120 4.26 0.00 0.00 45.31 45.31 0.00 10 11 0.0 17.7 0.0 120 4.26 0.00 6.79 45.31 38.52 6.79 11 12 0.0 16.7 0.0 120 4.26 0.00 6.35 38.52 32.17 6.35 8 100 286.2 4.5 19.0 120 2.63 20.21 0.00 45.74 40.99 4.75 100 101 286.2 20.0 0.0 120 2.63 20.21 0.00 40.99 36.95 4.04 101 102 192.1 19.0 12.0 120 2.63 9.66 0.00 36.95 33.96 2.99 102 103 128.7 20.0 0.0 120 2.63 4.60 0.00 33.96 33.04 0.92 101 104 94.1 11.0 12.0 120 2.63 2.58 0.00 36.95 36.36 0.59 104 105 47.8 30.0 36.0 120 2.63 0.73 0.00 36.36 35.87 0.48 105 106 47.8 51.0 12.0 120 2.15 1.96 0.00 35.87 34.64 1.23 104 107 46.3 60.0 70.0 120 2.15 1.85 0.00 36.36 33.95 2.41 106 107 47.8 20.0 15.0 120 2.15 1.96 0.00 34.64 33.95 0.69 108 109 45.6 20.0 15.0 120 2.15 1.80 0.00 29.48 28.85 0.63 107 108 94.1 53.0 12.0 120 2.15 6.88 0.00 33.95 29.48 4.47 109 110 45.6 44.0 12.0 120 2.15 1.80 0.00 28.85 27.85 1.01 110 111 45.6 30.0 18.0 120 2.15 1.80 0.00 27.85 26.98 0.86 108 111 48.5 54.0 70.0 120 2.15 2.02 0.00 29.48 26.98 2.50 111 112 94.1 32.0 0.0 120 2.15 6.88 0.00 26.98 24.78 2.20 112 113 157.6 20.0 18.0 120 2.15 17.86 0.00 24.78 18.00 6.79 113 116 194.1 7.0 6.0 120 2.15 26.27 0.00 18.00 14.58 3.42 116 117 95.1 15.0 0.0 120 2.15 7.01 0.00 14.58 13.53 1.05 102 112 63.4 147.0 130.0 120 2.15 3.31 0.00 33.96 24.78 9.17 103 114 128.7 110.0 6.0 120 2.15 12.27 0.00 33.04 18.81 14.23 114 115 82.2 12.0 0.0 120 2.15 5.35 0.00 18.81 18.17 0.64 115 113 36.5 8.0 6.0 120 2.15 1.19 0.00 18.17 18.00 0.17 116 118 99.0 7.5 9.0 120 1.69 24.82 0.65 14.58 9.84 4.75 117 121 95.1 7.5 9.0 120 1.69 23.04 0.65 13.53 9.08 4.45 118 119 63.9 12.0 0.0 120 1.69 11.04 0.00 9.84 8.51 1.32 121 122 61.4 12.0 0.0 120 1.69 10.24 0.00 9.08 7.85 1.23 119 120 31.2 12.0 0.0 120 1.45 6.09 0.00 8.51 7.78 0.73 122 123 30.0 12.0 0.0 120 1.45 5.65 0.00 7.85 7.17 0.68 114 124 46.5 1.5 5.0 120 1.45 12.71 0.65 18.81 17.33 1.48 115 125 45.7 1.5 5.0 120 1.45 12.29 0.65 18.17 16.72 1.45 THE MAXIMUM VELOCITY OF 17.08 FT /S OCCURS BETWEEN NODES 113 AND 116 HYDRAULIC CALCULATIONS ACCURACY CHECKS (UNBALANCED PRESSURE IN LOOPS): LOOP # 1 - NODES: 104 107 108 111 112 102 101 104 UNBALANCED PRESSURE = - 0.0059 PSI LOOP # 2 - NODES: 112 113 115 114 103 102 112 UNBALANCED PRESSURE = - 0.0051 PSI LOOP # 3 - NODES: 107 106 105 104 107 UNBALANCED PRESSURE = - 0.0000 PSI • • .•• • • • .•• •• •• • • • • •• •• • • • • • • • • • • • • • • • ••• • • • • • • • • • • • • • • • ••• • • • • ••• LOOP # 4 - NODES: 111 110 109 108 111 ••• • • • • •• UNBALANCED PRESSURE = 0.0000 PSI • • • •• • • • , • :• • • • .. • • • • • • • • • • • . • • • • • • • • • • • • + • ••• • • *********************************** * * * * * * * * * * * * * * * * * * * * * * * ** * * * *** •• • • • •• •.• •• * * * ** END OF SIMULATION * * * ** • • • • • • • • • •• • • • • • ••• •• HYDRAULIC Di&TA° $I 1ET DESIGN: LOCATION: PROJECT: AREA: DESIGN: HOSE ALLOWANCE: CONSTRUCTION: SYSTEM TYPE: SPRINKLER TYPE: C- FACTOR: FLOW 'PEST: CALCULATION SUMMARY: FIRE PUMP: MULLER FIRE PROTECTION INC 3200 N.W. 38 STREET MIAMI, FLORIDA 33142 VILLAGE DEL MAR SE CORNER OF 105 ST. AND BISCAYNE BLVD. MIAMI SHORES, FLORIDA THIRD FLOOR UNIT C-4 REMOTE HEADS AREA 3 N.F.P.A. 13R INSIDE: 50 GPM OUTSIDE: 50 GPM CONCRETE SLAB WITH CONCRETE BLOCK EXTERIOR AND INTERIOR MAIN DIVIDING WALLS. INTERIOR PART H'IONS TO BE METAL STUD AND DRYWALL WITH DRYWALL CEILINGS WET .... • DATV,;,„MiseitCH 11, 2005 • • • • • • • • • .. .. • ......• TYCO LF -II RESIDENTIAL CHROME RECESSED PENDENT 155 DEG 1/2 NPT K =4.9 TYCO LF -II RESIDENTIAL CHROME HORIZONTAL SIDEWALL 155 DEG 1/2 NPT K=4.2 INSIDE: C =120 STEEL C=150 CPVC PLASTIC UNDERGROUND: C =140 DUCTILE IRON C =150 C -900 DR14 PLASTIC 65 PSI STATIC 45 PSI RESIDUAL @ 1700 GPM FLOW 62.75 PSI @ 72.73 GPM CITY CONNECTION N/A i 3 � < i<1 fl +O t- q d 4' N G.P.M. MULTIPLY SCALE BY j' � rg .« QQ r 0 13 • • •••s • 6 7 6 9 10 11 12 yy • • • • • 1 . - iiuhIIIElalLi�I8LL1I 1pIHIii nnniui■uiaMiu■ - iiiiillintiiii 1111111M8111111111111111 , INMENIMMilinnillin Mignini a i1.���� j!IIIIIIIIIIIIHHIIUIIIII il lili lli lliiiiiiii11111111 t UI[!1IIi1iiiiir!!!flhlII■ - iBS.!1I■1�7 5 X51 * ** FIRENET * ** HYDRAULIC ANALYSIS OF A FIRE PROTECTION SPRINKLER SYSTEM VERSION 2.2 - JANUARY 1992 DATE FOR THIS COMPUTER RUN = 03 -11 -05 - TIME = 04:01:11 ID FOR THIS COMPUTER RUN = THIRD FLOOR UNITC -4 REMOTE HEADS INPUT DATA FILE NAME = A:\14UNT3FC.DAT OUTPUT DATA FILE NAME = A: \14UNT3FC.OUT ��•��. •��• • • • • • • • • • .••. • • (•.. • • • * * * * * * * * * * * ** SPRINKLER SYSTEM DATA SUMMARY * * * * * * * * * * * ***** • • ••• • *********************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** • • • WATER SUPPLY CHARACTERISTICS: STATIC PRESSURE = 65 PSI RESIDUAL PRESSURE = 45 PSI RESIDUAL FLOW = 1700 GPM ELEVATION OF PRESSURE GAGE = 2 FT. FLOW REQUIREMENTS: OUTSIDE HOSE FLOW REQUIREMENT (AT SUPPLY) = 0 GPM INSIDE HOSE FLOW REQUIREMENT (AT LOCATION 0 ) = 0 GPM TOTAL SPRINKLER SYSTEM FLOW REQUIRED (BASE OF RISER) = 0 GPM SPRINKLER INFORMATION: MAXIMUM SPACING OF SPRINKLER HEADS = 16 FT. MAXIMUM SPACING OF BRANCH LINES = 16 FT. REQUIRED MINIMUM FLOW (PER SPRINKLER) = 16 GPM REQUIRED MINIMUM FLOW DENSITY = .05 GPM /SQ. FT. OTHER SPRINKLER SYSTEM DATA: DEFAULT VALUE FOR C- FACTOR = 120 NUMBER OF BOOSTER PUMPS = 0 SUMMARY OF SPRINKLER OPERATION: SPRINKLER CONSTANT = 4.9 LOCATION OF OPERATING SPRINKLERS: 316 LOCATION OF OPERATING SPRINKLERS: 319 SPRINKLER CONSTANT = 4.2 LOCATION OF OPERATING SPRINKLERS: 315 LOCATION OF OPERATING SPRINKLERS: 318 • * ******* ** ******* ** ******* ** ******* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * •••• • • •••• • • • • •• • • • •• • • • • • • • • • •••• •• • • • ▪ • • • • .. • • .• • • ************************************* * * * * * * * * * * * * * * * * * * * * * * * * *** * *• • * * * * * * * * * * * * ** PIPE DATA SUMMARY * * * * * * * * * * * **** ************************************* * * * * * * * * * * * * * * * * * * * * * * * * **** *.• • NUMBER OF PIPES = 26 NUMBER OF JUNCTIONS = 27 NUMBER OF LOOPS = 0 FROM TO DIAM. HW -C LENGTH EQ. LN. EL. DIFF. (IN.) (FT.) (FT.) (FT.) 1 2 4.070 150 70.0 24.2 -5.0 2 3 4.070 150 12.0 %2116.4 0.0 3 5 4.070 150 110.0 31.7 0.0 5 6 4.260 120 4.0 10.0 4.0 6 7 4.260 120 4.0 10.0 0.0 7 8 4.260 120 10.0 10.0 9.0 8 9 4.260 120 2.0 0.0 1.0 9 10 4.260 120 3.0 10.0 0.0 10 11 4.260 120 17.7 0.0 15.7 11 12 4.260 120 16.7 0.0 14.7 12 300 2.154 120 1.0 6.0 0.0 300 301 2.154 120 17.0 9.0 0.0 301 302 2.003 150 84.0 120.9 0.0 302 303 2.003 150 70.0 99.8 0.0 303 304 2.003 150 3.0 12.1 0.0 304 305 2.003 150 12.0 13.6 0.0 305 310 1.598 150 12.0 24.2 0.0 310 311 1.598 150 5.0 12.1 0.0 311 312 1.394 150 4.0 1.5 0.0 312 313 1.394 150 5.0 1.5 0.0 313 314 1.101 150 8.0 19.7 0.0 314 315 1.101 150 4.3 19.7 -0.3 310 316 1.101 150 2.3 10.6 -0.3 313 317 1.101 150 2.0 9.1 0.0 317 318 1.101 150 3.3 19.7 -0.3 317 319 1.101 150 -0.3 9.1 -0.3 * * * * * * * * ** • • .. •. ** *******xx xx x* ***** * * * * * * * * * * * * * * * * * * * * * * * * * ** * * ** *********************************** * * * * * * * * * * * * * * * * * * * * * * * * * * ** * ** * * ** HYDRAULIC ANALYSIS WITH REQUIRED FLOW Al REMOTE HEAD * * ** • • .• • • • • ••• • • • • • • •• • • • • •.•• •• • • • • • • • • • • •• • • • . • • • •• • • • • • • • • • • • • • •••• • • • • • •• • • • •• • • • • • • * ** *SUMMARY OF SPRINKLER SYSTEM OPERATION * * ** THE FOLLOWING SPRINKLERS ARE OPERATING THE TOTAL SPRINKLER FLOW DELIVERED = 72.76 GPM THE MINIMUM DENSITY PROVIDED BY THIS SYSTEM IS 0.062 GPM /SQ FT WATER SUPPLY CHARACTERISTICS LOCATION AT PIPE NO 1 STATIC PRESSURE = 65 PSI RESIDUAL PRESSURE = 45 PSI AT 1700 GPM OPERATING PRESSURE = 62.75 PSI AVAILABLE PRESSURE = 64.94 PSI AT 72.73 GPM * * * * * * * ** EXCESSIVE (OR REQUIRED) SUPPLY PRESSURE = 2.19 PSI * * * * * * * ** *********************************** ** * * * * * * * * * * * * * * * * * * * * * * * * * * * ** * * * * * * * * * * ** SUMMARY OF HYDRAULIC CALCULATIONS * * * * * * * * * * * ** *********************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** •••• • • • • •••• • • • • • • • ••• • • • • • •• • • • • • •••• • • • • • • • • •••• • •• LOCATION SPRINKLER K ELEVATION FLOW PRESSURE • • ...r 316 4.90 38.99 21.43 19.12 •• •• •• • 319 4.90 38.99 18.95 14.95 • • • • 315 4.20 38.99 16.39 15.22 .•.•.. 318 4.20 38.99 16.00 14.51 • ••. •••• •• • • ••• • • • • • NODES FLOW PIPE EQV. H -W DIA. PSI/ ELEV. START END DIFF. FROM -TO (GPM) (FT.) FT -C- IN. 100 -FT PSI. PSI. PSI. PSI. 1 2 72.7 70.0 24.2 150 4.07 0.13 -2.17 62.75 64.80 -2.05 2 3 72.7 12.0 %2116.4 150 4.07 0.13 0.00 64.80 62.09 2.71 3 5 72.7 110.0 31.7 150 4.07 0.13 0.00 62.09 61.91 0.18 5 6 72.7 4.0 10.0 120 4.26 0.15 1.73 61.91 60.15 1.75 6 7 72.7 4.0 10.0 120 4.26 0.15 0.00 60.15 60.13 0.02 7 8 72.7 10.0 10.0 120 4.26 0.15 3.90 60.13 56.20 3.93 8 9 72.7 2.0 0.0 120 4.26 0.15 0.43 56.20 55.77 0.44 9 10 72.7 3.0 10.0 120 4.26 0.15 0.00 55.77 55.75 0.02 10 11 72.7 17.7 0.0 120 4.26 0.15 6.79 55.75 48.93 6.81 11 12 72.7 16.7 0.0 120 4.26 0.15 6.35 48.93 42.55 6.38 12 300 72.7 1.0 6.0 120 2.15 4.27 0.00 42.55 42.26 0.30 • • • • 300 301 72.7 301 302 72.7 302 303 72.7 303 304 72.7 304 305 72.7 305 310 72.7 310 311 51.3 311 312 51.3 312 313 51.3 313 314 16.4 314 315 16.4 310 316 21.4 313 317 34.9 317 318 16.0 317 319 18.9 17.0 84.0 70.0 3.0 12.0 12.0 5.0 4.0 5.0 8.0 4.3 2.3 2.0 3.3 -0.3 9.0 120.9 99.8 12.1 13.6 24.2 12.1 1.5 1.5 19.7 19.7 10.6 9.1 19.7 9.1 120 2.15 4.27 0.00 150 2.00 4.02 0.00 150 2.00 4.02 0.00 150 2.00 4.02 0.00 150 2.00 4.02 0.00 150 1.60 12.08 0.00 150 1.60 6.33 0.00 150 1.39 12.31 0.00 150 1.39 12.31 0.00 150 1.10 4.69 0.00 150 1.10 4.69 -0.14 150 1.10 7.70 -0.14 150 1.10 19.06 0.00 150 1.10 4.49 -0.14 150 1.10 6.13 -0.14 42.26 41.15 41.15 32.91 32.91: 2008 26.08 . 25.47 25.47"24M5 2.'03' 24.45"21!157 4.37 20.07..'.1x.99 il'.0t. 18.99 'f31 . 0.tt 18.31 17.51 l! . 16.21: 1543 0 20.07. 19 17.51%1540 15.40 14.51 15.40 15.01 0.39 THE MAXIMUM VELOCITY OF 11.77 FT /S OCCURS BETWEEN NODES 313 AND 317 *********************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** * * * ** END OF SIMULATION * * * ** .cr. w • HYDRAULIC DATA SHEET DESIGN: LOCATION: PROJECT: AREA: DESIGN: HOSE ALLOWANCE: CONSTRUCTION: SYSTEM TYPE: SPRINKLER TYPE: C- FACTOR: FLOW TEST: CALCULATION SUMMARY: FIRE PUMP: MULT .FR FIRE PROTECTION INC 3200 N.W. 38 STREET MIAMI, FLORIDA 33142 DATE' MARCH 11, 2005 • • • • •••• • •• • • • • • • • .. • VILLAGE DEL MAR SE CORNER OF 105 ST. AND BISCAYNE BLVD. MIAMI SHORES, FLORIDA WET INSIDE: C =120 STEEL C =150 CPVC PLASTIC UNDERGROUND: C =140 DUCTILE IRON C =150 C -900 DR14 PLASTIC • • .... • • ••• • • .. • • THIRD FLOOR UNIT B-4 REMOTE BEADS AREA 3 N.F.P.A. 13R INSIDE: 50 GPM OUTSIDE: 50 GPM CONCRETE SLAB WITH CONCRETE BLOCK EXTERIOR AND INTERIOR MAIN DIVIDING WALLS. INTERIOR PARTHIONS TO BE METAL STUD AND DRYWALL WITH DRYWALL CEILINGS TYCO LF -II RESIDENTIAL CHROME RECESSED PENDENT 155 DEG 1/2 NPT K=4.9 TYCO LF -II RESIDENTIAL CHROME HORIZONTAL SIDEWALL 155 DEG 1/2 NPT K=4.2 65 PSI STATIC 45 PSI RESIDUAL @ 1700 GPM FLOW 56.7 PSI @ 70.35 GPM CITY CONNECTION N/A P.S.1. MULTIPLY SCALE BY e 4 6 7 8 9 O i iiiiimmommiu mivammuemsommosumismaaurnommaaarrmomminranueaonumrmrommo mmirserusihrhrrsirrmiuma sss■ss■■ssssssasssssssasas■■ saes■ sss■■ ss ■■■■s■s■■sss■czWiuss■u■s■■sr: s■sss■nnc■h ■■srsrsrPnssssssss as•■ s■s ssss■■■ sssssssli ■1111ssommu■sss■■■■u■■■■111■r sr..s■su■■■ jigs ■1■111■1■sssssrssrsrssu■sus■r sss sassasssss■sessss■■asaaasaaass■ ssss■ sssssss sssssssazacissssasss. in : ssss•Joa 000 sasrsrrssrssssrttt 11111■ ■11111■ ■1111 ■1 ■11 ■1111 ■11■ ■1111111■ ■511■ MI6■ 11■■ 1ANC511■ r; ■■1 115 I 811111 AuANIIA 111111 ■ ■ ■ 111 ■ / ■ 1351111181111111 11111111111111111 ■1111111111111111111OPPI :111(11111W1 11111111111111111111111111 .999 11111■ 1111 111111111111111151111111151 111111111151111■i1911 111111 11.0 1 r 4111 114 WWWWt 1111 GC 11 c 11111[311 ■ 11■ 811511 181111111511188111818511811188 11118111111151uuel1u1111mr !151151aaaarmer 111 115111111111111/ 11111111I11111111I1111 11Iuuuui111IrewJIU11111` 7I111111IlI *m11uIflhPPIIIIIIIc 1111111111111111115 11111 11111 / 11111111111111111111111:1 1 11111111M11111111101I0111131CIC111111111 111111111111111111111111111111111111111111111111111111Ei:: 111111111111111111111111011111 . 111111111111111111 111111111111111 111111111111111111111! 111111111111111111111dl1ll11111 11111111111111111111111111111111111111111111111111111MIIN1111111111111111d111111111AI000IIIIILMt 111111111111111111111111111111111111111111111111111111111111111111111111111311414IIIIII0000IIIIIF #l11 111111111111111111111111 111111111111111111111111111111111ri111111111111111111di11i1 IIIeGIFGF1111L1 111111111111111111111111111111111111111i1111111111111111111111111111111111111111111111G011G1111111 111111111111111111 11111111111111111111111111111111111111f11111111111111111111111111111111111111111111 11111111111111111111111111111111111111111111111111111111 1111IIIIIIIIN111111111111111111111111111111 11111111111111111111111111111111111111111111111111111111 11111111111111111111111IIIIIIIII11111111111 11111111111111111IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII1911I1I1I11111111111111III111111111111111111I1 11111111111111111II11I1IIII111111111111111II1111I11111111I111111111I11111111111111111111111111111111 11111111111111111111111111111111111111111111111111111611111111111111111111111111111 11111111111111111 1111111111111111111111111111111111111111111111111111111111111111111111111111111111111111 111111111111 1111111111111111111111111111111111111111111111111111► 1111111111111111111111 11111111111111111111111111 1111111111111111111111111111111111111111111111111111 111111111111111111111111111111111111111111111111 111111nnnn I11111111111111111111I11111Iui 11111111111 1111111111111111I11I1II111I1111111111111111111111 1111111111 IIIIIIIIIIII111111111111111111111I111111111I1111111111111111111111111111111111111111111111 1111111111111111111111111111111111111111IIIII111111111111111111111111111111111111111111111 ;11111111 111111111111111111111111111111111111111111111111W111111111111111111111111111111111111111101111111 11111111111111111111111111111111111111111111111111111111111111111111111111111111IIn1111111111111111 111111111111111111111111111111111111111111111111111111IIIIIIIIIUh1111111111111111111111111111111111 1111111111111111111111111111111111111111111111► 11111111111111111111111I1111111111II1 11111111111111111 111111111111111111111111111111IIIIIIIIII111111I11111111111111111111111111111111111111111111111111111 111111111111111111111111111111IIIIIIIIIIIIII1Il! IIIIIIII11 1IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII IIIIII1III11111111111111IIIIIIIIIIIIIIIIIIIIIIIIIIIII1111111IIIIIIIIIII111111111IIIIIIIIIIIIi811111 IIIIIIIIIIIIIIIIIIIIIIIIIIIi111111111111111111I1 1i 1111IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII 11111111111111111111111111111I11111111111111111I401111111111111111111IIIIIIIIIIIIIII11IIIIIIIIIII IIIIIIIIIIIIIIIIIIIIIIIIIIIIII11111IIIIII! IIIIII' P111111111111111111111111111111111IIIIIIIIIIIIIII IIIII111111111111111111111111111111111111111111i! iiil1l111111111111111I1111111111111111111111111111 111111111111111111111111111111111111111P IIIIIIIi11111111111111111111111111111111IIIII111111111111111 IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIilIllllIIII11I11IIllllIIII111111IIIIIlIIIIilllIIIlllIlIlIIIII IIIIIIIIIIIIIIINIIIIIIIIIIIII111111111111IIIIIIIIIIIIIINIIIIIIIIIIIIIIIIIIIII11111111111111II11111 IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII IIIIIIIIII1111111111 III II IIIII II111111II IIIIIIIIII IIIII IRII IIIII IIIII IIIII IIIII IIII I NII I N111111II IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIHIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII1IIIIIIIIIIIII IIIIII11111111111111II1I1I11111I11IIII1111111111u1IIIIIIIII1111111111IIIIIIIIIINIIIIIIIIIIIIIIIIII 1111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111 III IIIII111111111111111IIIIII111111I111111111111III111111I1111111111111111111III1111111111111111111 0 1 Z 3 ►zed a C r r 0 a r m w 19r5b p 2ta► * ** FIRENET * ** HYDRAULIC ANALYSIS OF A FIRE PROTECTION SPRINKLER SYSTEM VERSION 2.2 - JANUARY 1992 DATE FOR THIS COMPUTER RUN = 03 -11 -05 - TIME = 04:29:48 ID FOR THIS COMPUTER RUN = THIRD FLOOR UNIT B -4 REMOTE HEADS INPUT DATA FILE NAME = A: \14UNT3FB.DAT OUTPUT DATA FILE NAME = A: \14UNT3FB.OUT * * * * * * * * * * * ** SPRINKLER SYSTEM DATA SUMMARY * * * * * * * * * * * * * * ** .... • • ************************************* * * * * * * * * * * * * * * * * * * * * * * * * *.* * *0 •••• • • • .• • WATER SUPPLY CHARACTERISTICS: STATIC PRESSURE = 65 PSI RESIDUAL PRESSURE = 45 PSI RESIDUAL FLOW = 1700 GPM ELEVATION OF PRESSURE GAGE = 2 FT. SPRINKLER INFORMATION: MAXIMUM SPACING OF SPRINKLER HEADS = 16 FT. MAXIMUM SPACING OF BRANCH LINES = 16 FT. REQUIRED MINIMUM FLOW (PER SPRINKLER) = 16 GPM REQUIRED MINIMUM FLOW DENSITY = .05 GPM /SQ. FT. OTHER SPRINKLER SYSTEM DATA: DEFAULT VALUE FOR C- FACTOR = 120 NUMBER OF BOOSTER PUMPS = 0 SUMMARY OF SPRINKLER OPERATION: SPRINKLER CONSTANT = 4.2 LOCATION OF OPERATING SPRINKLERS: 324 LOCATION OF OPERATING SPRINKLERS: 326 327 SPRINKLER CONSTANT = 4.9 LOCATION OF OPERATING SPRINKLERS: 325 • . . . . • • Oslo • • •• •• • • •• ** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** • • • • . •• • • . • •. • • • • • • • .• O 0 00 • • • .. • • • • • • ▪ • • • •••• • • FLOW REQUIREMENTS: • • • •. • • ••• • OUTSIDE HOSE FLOW REQUIREMENT (AT SUPPLY) = 0 GPM • • • . • INSIDE HOSE FLOW REQUIREMENT (AT LOCATION 0 ) = 0 GPM TOTAL SPRINKLER SYSTEM FLOW REQUIRED (BASE OF RISER) = 0 GPM *********************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** * * * * * * * * * * * * ** PIPE DATA SUMMARY * * * * * * * * * * * * * ** *********************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** NUMBER OF PIPES = 24 NUMBER OF JUNCTIONS = 25 NUMBER OF LOOPS = 0 FROM TO DIAM. HW -C LENGTH EQ. LN. EL. DIFF. (IN.) (FT.) (FT.) (FT.) 1 2 4.070 150 70.0 24.2 -5.0 2 3 4.070 150 12.0 %2116.4 0.0 3 5 4.070 150 110.0 31.7 0.0 5 6 4.260 120 4.0 10.0 4.0 6 7 4.260 120 4.0 10.0 0.0 7 8 4.260 120 10.0 10.0 9.0 8 9 4.260 120 2.0 0.0 1.0 9 10 4.260 120 3.0 10.0 0.0 10 11 4.260 120 17.7 0.0 15.7 11 12 4.260 120 16.7 0.0 14.7 12 300 2.154 120 1.0 6.0 0.0 300 301 2.154 120 17.0 9.0 0.0 301 302 2.003 150 84.0 120.9 0.0 302 303 2.003 150 70.0 99.8 0.0 303 304 2.003 150 3.0 12.1 0.0 304 305 2.003 150 12.0 13.6 0.0 303 320 1.394 150 3.0 9.1 0.0 320 321 1.394 150 2.0 1.5 0.0 321 322 1.394 150 1.0 1.5 0.0 322 323 1.101 150 5.0 1.5 0.0 323 324 1.101 150 23.3 33.3 -0.3 323 327 1.101 150 1.3 24.2 -0.3 320 325 1.101 150 2.8 16.6 -0.8 321 326 1.101 150 1.3 24.2 -0.3 • • • • *********************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** *********************************** * * * * * * * * * * * * * * * ** * * * * * * * * * * * * ** * * ** HYDRAULIC ANALYSIS WITH REQUIRED FLOW AT REMOTE HEAD * * ** *********************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** • • • •••• • • • • •• • • ••• • • • • • .. • • • • •• • • • • • • • • •••• • •• •••• • • • • • •• •• •• • • .� • • • •••• • • • • •••• • • • • • •• • • • • • • • • •• • * ** *SUMMARY OF SPRINKLER SYSTEM OPERATION * * ** THE FOLLOWING SPRINKLERS ARE OPERATING LOCATION 324 326 327 325 THE TOTAL SPRINKLER FLOW DELIVERED = 70.37 GPM THE MINIMUM DENSITY PROVIDED BY THIS SYSTEM IS 0.062 GPM /SQ F/ .•• •• • WATER SUPPLY CHARACTERISTICS LOCATION AT PIPE NO 1 STATIC PRESSURE = 65 PSI RESIDUAL PRESSURE = 45 PSI AT 1700 GPM OPERATING PRESSURE = 56.7 PSI AVAILABLE PRESSURE = 64.94 PSI AT 70.35 GPM * * * * * * * ** NODES FLOW FROM -TO (GPM) SPRINKLER K 4.20 4.20 4.20 4.90 1 2 70.4 2 3 70.4 3 5 70.4 5 6 70.4 6 7 70.4 7 8 70.4 8 9 70.4 9 10 70.4 10 11 70.4 11 12 70.4 12 300 70.4 300 301 70.4 301 302 70.4 302 303 70.4 303 304 0.0 EXCESSIVE (OR REQUIRED) SUPPLY PRESSURE = 8.23 *********************************** * * * * * * * * * * * * * * * * * * * * * * * * * ** * * ** * * * * * * * * * * ** SUMMARY OF HYDRAULIC CALCULATIONS * * * * * * * * * * * ** *********************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** PIPE (FT.) 70.0 12.0 110.0 4.0 4.0 10.0 2.0 3.0 17.7 16.7 1.0 17.0 84.0 70.0 3.0 ELEVATION FLOW PRESSURE 38.99 16.00 14.51 38.99 17.28 16.93 38.99 16.62 15.67 38.49 20.47 17.45 EQV. FT H -W DIA. -C- IN. 24.2 150 4.07 $2116.4 150 4.07 31.7 150 10.0 120 10.0 120 10.0 120 0.0 120 10.0 120 0.0 120 0.0 120 6.0 120 9.0 120 120.9 150 99.8 150 12.1 150 4.07 4.26 4.26 4.26 4.26 4.26 4.26 4.26 2.15 2.15 2.00 2.00 2.00 • 0000 • • 0000 .• .• • • • • •••• • • 0000 • •• • •• • • •• • • • • • •• • • • • • • • • • •••• • • • • ...• PSI• * *4**0 * * ** •• • • ••• • • • •• • PSI/ ELEV. START END DIFF. 100 -FT PSI. PSI. PSI. PSI. 0.12 -2.17 56.71 58.76 -2.05 0.12 0.00 58.76 56.21 2.55 0.12 0.00 56.21 56.05 0.17 0.14 1.73 56.05 54.29 1.75 0.14 0.00 54.29 54.27 0.02 0.14 3.90 54.27 50.34 3.93 0.14 0.43 50.34 49.91 0.44 0.14 0.00 49.91 49.89 0.02 0.14 6.79 49.89 43.08 6.81 0.14 6.35 43.08 36.70 6.38 4.01 0.00 36.70 36.42 0.28 4.01 0.00 36.42 35.38 1.04 3.78 0.00 35.38 27.63 7.75 3.78 0.00 27.63 21.21 6.42 0.00 0.00 21.21 21.21 0.00 304 305 0.0 12.0 13.6 150 2.00 0.00 0.00 21.21 21.21 0.00 303 320 70.4 3.0 9.1 150 1.39 22.09 0.00 21.21 18.55 2.67 320 321 49.9 2.0 1.5 150 1.39 11.69 0.00 18.55 18.14 0.41 321 322 32.6 1.0 1.5 150 1.39 5.32 '0.00 18.14 18.00 0.13 322 323 32.6 5.0 1.5 150 1.10 16.79 0.00 18.00 16.91 1.09 323 324 16.0 23.3 33.3 150 1.10 4.49 -0.14 16.91 14.51 2.40 323 327 16.6 4.3 24.2 150 1.10 4.82 -0.14 16.91 15.68 1.23 320 325 20.5 2.8 16.6 150 1.10 7.07 -0.36 18.55 17.53 1.02 321 326 17.3 1.3 24.2 150 1.10 5.17 -0.14 18.14 16.96 1.18 THE MAXIMUM VELOCITY OF 14.78 FT /S OCCURS BETWEEN NODES 303 AND 32Q"", • • •••• • • • •• • • ••• • • • •• • • *********************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * *** • •• •• * * * ** END OF SIMULATION * * * ** •••• • • • • •• • • • • •• •••• • • • •• • • • • • • • • • • • • • • •••• • • • • • • • • • • •• • • ••• • • • • • •• • Mar 04 05 03:18p DATE: 3/4/2005 LOCATION: 1200 N.E. 105th ST. D NUMBER: 05360 -00072 FEE: 250.00 STATIC PRESSURE: RESIDUAL PRESSUR HYDRANT FLOW: MIAMI -DADE COUNTY FIRE RESCUE DEPARTMENT FIRE ENGINEERING & WATER SUPPLY SERVICES FIRE FLOW REPORT SPRINKLER STATIC: SPRINKLER RESIDUAL: SPRINKLER FLOW: 70 PSIG PITOT 1: • 50 PSIG PITOT 2: PITOT 3: 1762.99177536369 AVAILABLE FLOW @ 20 PSIG: TIME OF TEST: 03/04/2005 TEST BY: Lt. M. Sheri!! ■ STATION: 30 PURPOSE: 2892 65 45 1700 COMMENTS: Requested by Roy Muller of MULLER FIRE PROTECTION, INC. 35 (1) 2.5 IN. PSIG 35 . ( ?) 2.5 Co.' PSIG • .. • • 4.5 PI1 •-•-eAlG • • • •••• •• • • • • • • • • •• • • .... •••• • • • •• • • p.2 • • • .. • • ...• • • • • •••• • • • • • •• • • • • • • • • • • •• • — "l./ J" 1 , l LI �� /exe.k O.I.0 SIGNITURE tqca I Fire &Building Products Technical Services: Tel: (800) 381 -9312 / Fax: (800) 791 -5500 Series LFII Residential Pendent Sprinklers 4.9 K- factor General Description The Series LFII (TY2234) Residential Pendent Sprinklers are decorative, fast response, frangible bulb sprinklers designed for use in residential occu- pancies such as homes, apartments, dormitories, and hotels. When aesthet- ics and optimized flow characteristics are the major consideration, the Series LFII (TY2234) should be the first choice. The Series LFII are to be used in wet pipe residential sprinkler systems for one- and two- family dwellings and mo- bile homes per NFPA 13D; wet pipe residential sprinkler systems for resi- dential occupancies up to and includ- ing four stories in height per NFPA 13R; or, wet pipe sprinkler systems for the residential portions of any occu- pancy per NFPA 13. The Series LFII (TY2234) has a 4.9 (70,6) K- factor that provides the re- quired residential flow rates at reduced pressures, enabling smaller pipe sizes and water supply requirements. The recessed version of the Series LFII (TY2234) is intended for use in areas with finished ceilings. It employs a two -piece Style 20 Recessed Es- cutcheon. The Recessed Escutcheon provides 1/4 inch (6,4 mm) of recessed IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 8 adjustment or up to 1/2 inch (12,7 mm) of total adjustment from the flush ceil- ing position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the pipe nipples to the sprinklers must be cut. The Series LFII (TY2234) has been designed with heat sensitivity and water distribution characteristics proven to help in the control of residen- tial fires and to improve the chance for occupants to escape or be evacuated. WARNINGS The Series LFII (TY2234) Residential Pendent Sprinklers described herein must be installed and maintained in compliance with this document, as well as with the applicable standards of the National Fire Protection Asso- ciation, in addition to the standards of any other authorities having jurisdic- tion. Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Sprinkler/Model Identification Number SIN TY2234 • • • •• •••• • • •••• SEPTEMBER, 2004 TFP4OO • • 1•••• • • 1•••• Page 2 of 8 Technical Data Approvals: UL and C -UL Listed. NYC Approved under MEA 44 -03 -E. Maximum Working Pressure: 175 psi (12,1 bar) Discharge Coefficient: K = 4.9 GPM/psilr (70,6 LPM/barli Temperature Rating: 155 °F /68 °C or 175 °F /79 °C Finishes: White Polyester Coated, Chrome Plated, or Natural Brass Physical Characteristics: Frame Brass Button Bronze Sealing Assembly Beryllium Nickel w/Teflont Bulb 3 mm dia. Glass Compression Screw Bronze Deflector Bronze Ejection Spring .... Stainless Steel tDuPont Registered Trademark Operation The glass Bulb contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass Bulb allowing the sprinkler to activate and flow water. Design Criteria The Series LFII (TY2234) Residential Pendent Sprinklers are UL and C -UL Listed for installation in accordance with the following criteria. NOTE When conditions exist that are outside the scope of the provided criteria, refer to the Residential Sprinkler Design Guide TFP490 for the manufacturer's recommendations that may be accept- able to the local Authority having Juris- diction. System Type. Only wet pipe systems may be utilized. Hydraulic Design. The minimum re- quired sprinkler flow rate for systems designed to NFPA 13D or NFPA 13R are given in Table A as a function of temperature rating and the maximum allowable coverage areas. The sprin- kler flow rate is the minimum required discharge from each of the total number of "design sprinklers" as speci- fied in NFPA 13D or NFPA 13R. For systems designed to NFPA 13, the number of design sprinklers is to be the four most hydraulically demanding sprinklers. The minimum required dis- charge from each of the four sprinklers is to be the greater of the following: • The flow rates given in Table A for NFPA 13D and 13R as a function of TFP400 temperature rating and the maxi- mum allowable coverage area. • A minimum discharge of 0.1 gpm /sq. ft. over the "design area" comprised of the four most hydraulically de- manding sprinklers for the actual coverage areas being protected by the four sprinklers. Obstruction To Water Distribution. Locations of sprinklers are to be in accordance with the obstruction rules of NFPA 13 for residential sprinklers. Operational Sensitivity. • For "Horizontal Ceilings" (maximum 2 inch rise for 12 inch run), the sprin- klers are to be installed with a deflec- tor to ceiling distance of 1 -3/8 to 4 inches or in the recessed position using only the Style 20 Recessed Escutcheon as shown in Figure 2. NOTES The "Beam Ceiling Design Criteria" section starting on Page 4 permits de- flector to ceiling distances up to 15 -3/4 inches. So as to help avoid obstructions to water distribution, a maximum 12 inch deflector -to- ceiling distance is permit- ted for NFPA 13D and NFPA 13R appli- cations where the sprinklers are located in closets. • For "Sloped Ceilings" (greater than 2 inch rise up to 8 inch rise for 12 inch run), the sprinklers are to be installed with a deflector to ceiling • • • • • • • • • • • • • Maximum Coverage Area (a) Ft. x Ft. (m x m) Maximum Spacing Ft. (m) Minimum Flow ib) and Residual Pressure For Horizontal Ceiling (Max. 2 Inch Rise for 12 Inch Run) Minimum Flow OS and Residual Pressure For Sloped Ceiling (Greater Than 2 Inch Rise Up To Max. 4 Inch Rise for 12 Inch Run) Minimum Flow (b) and Residual Pressure For Sloped Ceiling (Greater Than 4 Inch Rise Up To Max. 8 Inch Rise for 12 Inch Run) 155 °F /68 °C or 175F/79°C 155 °F /68 °C 175 °F /79 °C 155 °F /68 °C 175FI79°C 12 x 12 (3,7 x 3,7) 12 (3,7) 13 GPM (49,2 LPM) 7.0 psi (0,48 bar) 13 GPM (49,2 LPM) 7.0 psi (0,48 bar) 17 GPM (64,3 LPM) 12.0 psi (0,83 bar) 13 GPM (49,2 LPM) 7.0 psi (0,48 bar) 18 GPM (68,1 LPM) 13.5 psi (0,93 bar) 14 x 14 (4,3 x 4,3) 14 (4,3) 13 GPM (49,2 LPM) 7.0 psi (0,48 bar) 13 GPM (49,2 LPM) 7.0 psi (0,48 bar) 17 GPM (64,3 LPM) 12.0 psi (0,83 bar) 13 GPM (49,2 LPM) 7.0 psi (0,48 bar) 18 GPM (68,1 LPM) 13.5 psi (0,93 bar) 16 x 16 (4,9 x 4,9) 16 (4,9) 13 GPM (49,2 LPM) 7.0 psi (0,48 bar) 13 GPM (49,2 LPM) 7.0 psi (0,48 bar) 17 GPM (64,3 LPM) 12.0 psi (0,83 bar) 13 GPM (49,2 LPM) 7.0 psi (0,48par) 18 GPM %?1'1 • 13.5 psil0,93 bar) 18 x 18 (5,5 x 5,5) 18 (5,5) 17 GPM (64,3 LPM) 12.0 psi (0,83 bar) 17 GPM (64,3 LPM) 12.0 psi (0,83 bar) 17 GPM (64,3 LPM) 12.0 psi (0,83 bar) 17 GPM (64,3 L v1) 12.0 psi (0,83E94 • 3 GIN x87 •IrM) •22.0 psift,52 bar) 20 x 20 (6,1 x 6,1) 20 (6,1) 20 GPM (75,7 LPM) 16.7 psi (1,15 bar) 20 GPM (75,7 LPM) 16.7 psi (1,15 bar) 20 GPM (75,7 LPM) 16.7 psi (1,15 bar) 21 GPM (79,5•L4'M) 18.4 psi (1,27 bar) • N/A• • • • _ • (a) For coverage area dimensions less than or between those indicated, it is necessary to use the minima ed • flow fool I • next highest coverage area for which hydraulic design criteria are stated. • • • • • •• •• •• • (b) Requirement is based on minimum flow in GPM (LPM) from each sprinkler. The associated residual piassbrea are calculated using the nominal K- factor. Refer to Hydraulic Design Criteria Section for details. • • • • • • • • TABLE A • • •••• • NFPA 13D AND NFPA 13R HYDRAULIC DESIGN CRITERIA FOR THE SERIES LW0V2234) . ... RESIDENTIAL PENDENT AND RECESSED PENDENT SPRINKLERS • • • • • Page 2 of 8 Technical Data Approvals: UL and C -UL Listed. NYC Approved under MEA 44 -03 -E. Maximum Working Pressure: 175 psi (12,1 bar) Discharge Coefficient: K = 4.9 GPM/psilr (70,6 LPM/barli Temperature Rating: 155 °F /68 °C or 175 °F /79 °C Finishes: White Polyester Coated, Chrome Plated, or Natural Brass Physical Characteristics: Frame Brass Button Bronze Sealing Assembly Beryllium Nickel w/Teflont Bulb 3 mm dia. Glass Compression Screw Bronze Deflector Bronze Ejection Spring .... Stainless Steel tDuPont Registered Trademark Operation The glass Bulb contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass Bulb allowing the sprinkler to activate and flow water. Design Criteria The Series LFII (TY2234) Residential Pendent Sprinklers are UL and C -UL Listed for installation in accordance with the following criteria. NOTE When conditions exist that are outside the scope of the provided criteria, refer to the Residential Sprinkler Design Guide TFP490 for the manufacturer's recommendations that may be accept- able to the local Authority having Juris- diction. System Type. Only wet pipe systems may be utilized. Hydraulic Design. The minimum re- quired sprinkler flow rate for systems designed to NFPA 13D or NFPA 13R are given in Table A as a function of temperature rating and the maximum allowable coverage areas. The sprin- kler flow rate is the minimum required discharge from each of the total number of "design sprinklers" as speci- fied in NFPA 13D or NFPA 13R. For systems designed to NFPA 13, the number of design sprinklers is to be the four most hydraulically demanding sprinklers. The minimum required dis- charge from each of the four sprinklers is to be the greater of the following: • The flow rates given in Table A for NFPA 13D and 13R as a function of TFP400 temperature rating and the maxi- mum allowable coverage area. • A minimum discharge of 0.1 gpm /sq. ft. over the "design area" comprised of the four most hydraulically de- manding sprinklers for the actual coverage areas being protected by the four sprinklers. Obstruction To Water Distribution. Locations of sprinklers are to be in accordance with the obstruction rules of NFPA 13 for residential sprinklers. Operational Sensitivity. • For "Horizontal Ceilings" (maximum 2 inch rise for 12 inch run), the sprin- klers are to be installed with a deflec- tor to ceiling distance of 1 -3/8 to 4 inches or in the recessed position using only the Style 20 Recessed Escutcheon as shown in Figure 2. NOTES The "Beam Ceiling Design Criteria" section starting on Page 4 permits de- flector to ceiling distances up to 15 -3/4 inches. So as to help avoid obstructions to water distribution, a maximum 12 inch deflector -to- ceiling distance is permit- ted for NFPA 13D and NFPA 13R appli- cations where the sprinklers are located in closets. • For "Sloped Ceilings" (greater than 2 inch rise up to 8 inch rise for 12 inch run), the sprinklers are to be installed with a deflector to ceiling • • • • • • • • • • • • • TFP400 Components: 1 - Frame 2 - Button 3 - Sealing Assembly 4 - Bulb 5 - Compression Screw 6 - Deflector * * Temperature rating is indicated on Deflector. 7/16° (11,1 mm) NOMINAL MAKE -IN 1/2° NPT CROSS SECTION PENDENT ESCUTCHEON PLATE SEATING SURFACE WRENCH FLATS FIGURE 1 SERIES LFII (TY2234) RESIDENTIAL PENDENT AND RECESSED PENDENT SPRINKLERS 2 -7/8° DIA. (73,0 mm) •• • • ••• RECE fl T'ENDENY • •• • • •••• • • • • •••• • •• • • • • • •• •• •• • • • • • • STYLE 20 RECESSED €,CPJTCHEON •••• • •••• 7/16±1/8" (11,1±3,2 mm) FACE OF SPRINKLER FITTING MOUNTING SURFACE CLOSURE TY2234 2 -7/8° DIA. (73,0 mm) 2 -1/4" DIA. (57,2 mm) 1/2 °(12,7 mm) 1/4° (6,4 mm) MOUNTING PLATE 1 /8° (3,2 mm) 1 -3/8° (34,9 mm) 1 -1 /8° (28,6 mm) FIGURE 2 STYLE 20 RECESSED ESCUTCHEON FOR USE WITH THE SERIES LFII (TY2234) RESIDENTIAL PENDENT SPRINKLER distance of 1 -3/8 to 4 inches or in the recessed position using only the Style 20 Recessed Escutcheon as shown in Figure 2 Sprinkler Spacing. The minimum spacing between sprinklers is 8 feet (2,4 m). The maximum spacing be- tween sprinklers cannot exceed the length of the coverage area (Ref. Table A) being hydraulically calculated (e.g., maximum 12 feet for a 12 ft. x 12 ft. coverage area, or 20 feet for a 20 ft. x 20 ft. coverage area). Page 3 of 8 . • • • ...• • ••• • • • •• • WRENCH RECESS (END °A° USED FOR TY2234) WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 4 W -TYPE 7 RECESSED SPRINKLER WRENCH 1 • • 1•••• • • 1•••• • • • • • • • • • • Page 4 of 8 Beam Ceiling Design Criteria The Series LFII (TY2234) Residential Pendent Sprinklers are UL and C -UL Listed for installation in residential oc- cupancies with horizontal ceilings (i.e., slopes up to a 2 inch rise over a 12 inch run) with beams when installed in ac- cordance with the following criteria: General Information. The basic con- cept of this protection scheme is to locate the sprinklers on the underside of the beams, Ref. Figure 5, (not in the beam pockets); to identify the main beams that principally run in one direc- tion as "primary beams "; and, to iden- tify the beams that run principally per- pendicular to the main beams, as may be present (or in some cases may be necessary for proper sprinkler protec- tion), as "secondary beams ". Primary and Secondary Beam Types. Solid surface, solid or hollow core, combustible or non - combustible. Primary and Secondary Beam Posi- tioning. Directly attached to the un- derside of a combustible or non -com- bustible smooth ceiling at any elevation. Primary Beam Cross - Section: Maxi- mum depth of 14 inches and the maxi- mum width is unlimited. The cross -sec- tional shape of the primary beam may be rectangular to circular. Secondary Beam Cross - Section. Maximum depth to be no greater than the primary beam and the maximum width is unlimited. The cross - sectional shape of the secondary beam may be rectangular to circular. Primary Beam Spacing. The primary beams (Fig. 6A) are to be 3 ft. - 4 in. to 6 ft. from the compartment wall to cen- ter of the nearest beam and from cen- ter to center between beams. Secondary Beam Spacing. The sec- ondary beams principally run perpen- dicular to the primary beams. Secondary beams of a depth equal to the primary beam must be placed so that the beam pockets created by the primary beams do not exceed 20 feet in length (Fig. 6B). NOTE When the beam pockets created by the primary beams exceed 20 feet in length, the installation will require the use of secondary beams as described above. Otherwise, secondary beams need not be present. Secondary beams of a cross - sectional depth greater than one - quarter the depth of the primary beams are to be a minimum of 3 ft. - 4 in. from the compartment wall to center of the nearest beam and from center to cen- ter between beams (Fig. 6C). Secondary beams of a cross - sectional depth no greater than one - quarter the depth of the primary beams may be placed at any compartment wall to center of the nearest beam distance and from any center to center distance between beams (Fig. 6C). Lintels. Lintels over doorways exiting the compartment must be present. The minimum height for the lintels is 8 inches or no less than the depth of the Primary Beams, whichever is greater. Sprinkler Types. Series LFII (TY2234), 155F and 175F, Pendent and Recessed Pendent Residential Sprinklers. Sprinkler Coverage Area and Hy- draulic Design. The sprinkler cover- age areas and hydraulic design criteria as presented in the Table A for "Hori- zontal Ceilings" are to be applied. Sprinkler Position. The deflector to bottom of primary beams for the Series LFII (TY2234) Pendent Sprinklers or Series LFII (TY2234) Recessed Pen- dent Sprinklers is to be 1 -1/4 to 1 -3/4 inches (Fig. 5A). The vertical center- line of the Series LFII (TY2234) Pen- dent Sprinklers is to be no greater than half the primary beam cross - sectional width plus 2 inches from the centerline of the primary beam (Fig 5B). NOTES Core drilling of beams to allow the in- stallation of sprinkler drops requires consulting with a structural engineer. Where core drilling is not permitted, the previously stated sprinkler position criteria for the Series LFII (TY2234) Pendent Sprinklers allows for the sprinkler drop to be placed adjacent to the primary beam. Beam and Soffit Arrangements. A soffit is permitted to be placed around the perimeter of a compartment with the beam arrangement within the sof- fited area (Fig.7). The cross - section of the soffit may be any size as long as it does not create an obstruction to water distribution per the obstruction rules of NFPA 13 for residential sprinklers. When soffits are present, the pre- viously provided 3 ft. - 4 in. to 6 ft. "compartment wall to adjacent beam" distance for the primary and secon- dary beams is to be measured from the face of the soffit as opposed to the compartment wall. TFP400 A B E E t .. • MAXIMUM ONE -HALF BEAM WIDTH PLUS 2° (50,8 mm) • • • • •••• • • . s v 'sr • • TY2234 FIGURE 5 SPRINKLER POSITIONING UNDER PRIMARY BEAMS (Refer to the "Beam Ceiling Design Criteria" section) NOTE Although the distance to the beams is measured from the face of the soffit, the sprinkler coverage area is to be measured from the compartment wall. • .. • • •.•• • • • • • • • • TFP400 Page 5 of 8 ALL FIGURES: DISTANCES ARE MEASURED TO COMPARTMENT WALL FACES AND TO CENTERLINES OF BEAMS *REFER TO FIGURE 6B FOR SPANS EXCEEDING 20' -0° (6,1 m) PRIMARY BEAM COMPARTMENT WALLS SECONDARY BEAM PRIMARY * BEAM COMPARTMENT WALLS A= 3'- 4 °to6-0°(1,0to1,8m) FOR PRIMARY BEAMS HAV- ING A 14° (356 mm) MAXIMUM DEPTH 20'-0° (6,1 m) MAXI MUM • _ • • • • •••• • •• • FIGURE 6A PRIMARY BEAM SPANS UP TO 20' -0° (6,1 m) FIGURE 6B PRIMARY BEAM SPANS GREATER THAN 20' -0° (6,1 m) FIGURE 6C COMBINATIONS OF PRIMARY AND SECONDARY BEAMS 14° (356 mm) MAXIMUM FIGURE 6 BEAM ARRANGEMENTS (Refer to the "Beam Ceiling Design Criteria" section) • • • • • • • •••• • • • • • •• •• •• • A =3'-4° DOM MO • FOR PRIMARY B MS HAV- ING A 14° (356 mm) MAXIM& I • • • • • DEPTH • • • •••• B = 20'-0° (6,1 m) R1AXIMUY • • • • FOR SECONDARY BEAMS • • • • THAT ARE TO BE EQUAL IN DEPTH TO PRIMARY BEAMS AND THAT MUST BE IN PLACE SO THAT PRIMARY BEAM POCKETS DO NOT EXCEED 20' -0° (6,1 m) A.: 3'-4° to 6-0° (1,0 to 1,8 m) FOR PRIMARY BEAMS HAV- ING A 14° (356 mm) MAXIMUM DEPTH C = 3'-4° (1,0 m) MINIMUM FOR SECONDARY BEAMS HAVING DEPTHS GREATER THAN 25% OF PRIMARY BEAMS — or— C = ANY DISTANCE FOR SEC- ONDARY BEAMS HAVING DEPTHS UP TO 25% OF PRIMARY BEAMS • ••• • • • •• • • •• • • • • • •• • • • • •• • • • • • • • • • • • Page 6 of 8 SECONDARY BEAM PRIMARY BEAM FACE OF SOFFIT COMPARTMENT WALLS FIGURE 7 BEAM AND SOFFIT ARRANGEMENTS (Refer to the "Beam Ceiling Design Criteria" section) * USE DISTANCES SHOWN IN FIGURES 6A, 6B & 6C, EXCEPT MEASUREMENTS ARE TAKEN FROM FACES OF SOFFITS INSTEAD OF FROM COMPARTMENT WALL SURFACES • • • • • • • • • •• •• • • •••• • • •• •• • • • • • • • • • • -• • • •• • • • • ••• • • • •• • • •• • • • • • •• •••• • • • •• • • •••• • • • •••• • • Installation The Series LFII (TY2234) must be in- stalled in accordance with the follow- ing instructions: NOTES Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm). A leak tight 1/2 inch NPTsprinkler joint should be obtained with a torque of 7 to 14 ft.lbs. (9,5 to 19,0 Nm). A maxi- mum of 21 ft.lbs. (28,5 Nm) of torque is to be used to install sprinklers. Higher levels of torque may distort the sprinkler inlet with consequent leak- age or impairment of the sprinkler. Do not attempt to compensate for in- sufficient adjustment in an Escutcheon Plate by under- or over - tightening the Sprinkler. Readjust the position of the sprinkler fitting to suit. The Series LFII Pendent Sprinklers must be installed in accordance with the following instructions. Step 1. Pendent sprinklers are to be installed in the pendent position with the deflector parallel to the ceiling. Step 2. With pipe thread sealant ap- plied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W -Type 6 Sprinkler Wrench (Ref. Figure 3). With reference to Figure 1, the W -Type 6 Sprinkler Wrench is to be applied to the wrench flats. The Series LFII Recessed Pendent Sprinklers must be installed in ac- cordance with the following instruc- tions. Step A. Recessed pendent sprinklers are to be installed in the pendent posi- tion with the deflector parallel to the ceiling. Step B. After installing the Style 20 Mounting Plate over the sprinkler threads and with pipe thread sealant applied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step C. Tighten the sprinkler into the sprinkler fitting using only the W -Type 7 Recessed Sprinkler Wrench (Ref. Figure 4). With reference to Figure 1, the W -Type 7 Recessed Sprinkler Wrench is to be applied to the sprinkler wrench flats. Step D. After the ceiling has been in- stalled or the finish coat has been ap- plied, slide on the Style 20 Closure over the Series LFII Sprinkler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. • ••• • • • •• • Care and Maintenance TFP400 • The Series LFII (TY2234) must be maintained and serviced in accord- ance with the following instructions: • • • NOTES Absence of an Escutcheon Plate may delay the sprinkler operation in a fire situation. Before closing a fire protection system main control valve for maintenance work on the fire protection system which it controls, permission to shut down the affected fire protection sys- tem must be obtained from the proper authorities and all personnel who may be affected by this action must be no- tified. Sprinklers which are found to be leak- ing or exhibiting visible signs of corro- sion must be replaced. Automatic sprinklers must never be painted, plated, coated, or otherwise altered after leaving the factory. Modi- fied sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- • • • • • • • • • • • • TFP400 Page 7 of 8 age to the sprinklers - before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be re- placed. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section). The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. The in- stalling contractor or sprinkler manu- facturer should be contacted relative to any questions. NOTE The owner must assure that the sprin- klers are not used for hanging of any objects and that the sprinklers are only cleaned by means of gently dusting with a feather duster; otherwise, non - operation in the event of a fire or inad- vertent operation may result. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and /or national codes. Limited Warranty Products manufactured by Tyco Fire Products are warranted solely to the original Buyer for ten (10) years against defects in material and work- manship when paid for and properly installed and maintained under normal use and service. This warranty will ex- pire ten (10) years from date of ship- ment by Tyco Fire Products. No war- ranty is given for products or components manufactured by compa- nies not affiliated by ownership with Tyco Fire Products or for products and components which have been subject to misuse, improper installation, corro- sion, or which have not been installed, maintained, modified or repaired in ac- cordance with applicable Standards of the National Fire Protection Associa- tion, and/or the standards of any other Authorities Having Jurisdiction. Mate- rials found by Tyco Fire Products to be defective shall be either repaired or replaced, at Tyco Fire Products' sole option. Tyco Fire Products neither as- sumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of products. Tyco Fire Products shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer's representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CON- TRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THE- ORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LABOR CHARGES, RE- GARDLESS OF WHETHER TYCO FIRE PRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENT SHALL TYCO FIRE PRODUCTS' LI- ABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. THE FOREGOING WARRANTY IS MADE IN LIEU OF ANY AND ALL, OTHER WARRANTIES EXPRESS OR IMPLIED. INCLUDING WARRANTIES OF MERCHANTABILITY AND FIT- NESS FOR A PARTICULAR PUR- POSE,. Ordering Procedure When placing an order, indicate the full product name. Contact your local dis- tributor for availability.. Sprinkler Assembly: Series LFII (TY2234), K =4.9, Residen- tial Pendent Sprinkler with (specify) temperature rating and (specify) finish, P/N (specify). 155'F/68°C or Chrome Plated P g1!2b, -9 -155 155 °F /68 °C • • • • • • White Polyesyeg! . 51iiO -155 155 °F /68 °C • • • White • • • (RAL9010)b •.•..• • P/N 51201 -3-155 • Natural Brig • • • • IrI! i 5 1- Lt:1 -1 -155 • 175 °F /79 °C or • • • • • • • Chrome Plat • w •.... • P/N i i 201 -9 -175 175 °F /79 °C • • • White Polyti9ters • 175 °F /79 °C White • • • (RAL9O10) • 175 °F /79 °C • • Natural Brass..• ..• ..... PJR1 • 54-'01 -1 -175•' • •• • • ••• • • *Eastern Hemisphere sales viLy. Recessed Escutcheon: Specify: Style 20 Recessed Escutch- eon with (specify) finish, P/N (specify). 1/2° (15 mm) Style 20 Chrome Plated P/N 56 -705 -9 -010 1/2° (15 mm) Style 20 White Color Coated P/N 56- 705 -4-010 1/2' (15 mm) Style 20 White (RAL9010)* P/N 56- 705 -3-010 1/2° (15 mm) Style 20 Bright Brass Coated P/N 56 -705 -2 -010 *Eastern Hemisphere sales only. 1 -4-175 • P/61464. 01- 3-175• • • Sprinkler Wrench: Specify: W -Type 6 Sprinkler Wrench, P/N 56- 000 -6 -387. Specify: W -Type 7 Sprinkler Wrench, P/N 56- 850 -4 -001. • • • • • • • • • • Page 8 of 8 TFP400 TYCO FIRE PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 • • • • • •• • • •••• • • •• •• .. • • • • •••• • ••• • • • •• • ••• • • • • • • • • • • • • •• • • • • • •• • • • • • • • • • • • • • • • • • •••• • • • • • •• • • ••• • • • • • tqcci I Fire &Building Products Technical Services: Tel: (800) 381 -9312 / Fax: (800) 791 -5500 Series LFII Residential Horizontal Sidewall Sprinklers 4.2 K- factor General Description The Series LFII (TY1334) Residential Horizontal Sidewall Sprinklers are decorative, fast response, frangible bulb sprinklers designed for use in residential occupancies such as homes, apartments, dormitories, and hotels. When aesthetics and optimized flow characteristics are the major con- sideration, the Series LFII (TY1334) should be the first choice. The Series LFII are to be used in wet pipe residential sprinkler systems for one- and two- family dwellings and mo- bile homes per NFPA 13D; wet pipe residential sprinkler systems for resi- dential occupancies up to and includ- ing four stories in height per NFPA 13R; or, wet pipe sprinkler systems for the residential portions of any occu- pancy per NFPA 13. The Series LFII (TY1334) has a 4.2 (60,5) K- factor that provides the re- quired residential flow rates at reduced pressures, enabling smaller pipe sizes and water supply requirements. The recessed version of the Series LFII (TY1334) is intended for use in areas with finished walls. It employs a two -piece Style 20 Recessed Escutch- eon. The Recessed Escutcheon pro- vides 1/4 inch (6,4 mm) of recessed IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 8 adjustment or up to 1/2 inch (12,7 mm) of total adjustment from the flush mounting surface position. The adjust- ment provided by the Recessed Es- cutcheon reduces the accuracy to which the pipe nipples to the sprinklers must be cut. The Series LFII (TY1334) has been designed with heat sensitivity and water distribution characteristics proven to help in the control of residen- tial fires and to improve the chance for occupants to escape or be evacuated. WARNINGS The Series LFII (TY1334) Residential Horizontal Sidewall Sprinklers de- scribed herein must be installed and maintained in compliance with this document, as well as with the applica- ble standards of the National Fire Pro- tection Association, in addition to the standards of any other authorities hav- ing jurisdiction. Failure to do so may Impair the performance of these de- vices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Sprinkler/Model Identification Number SIN TY1334 APRIL, 2004 TFP41O .� .� • • • .... • • .... • • Page 2 of 8 TFP41O Components: 1 - Frame 2 - Button Assembly 3 - Sealing Assembly 4 - Bulb 5 - Compression Screw 6 - Deflector * Temperature rating is indicated on top of Deflector. 7/16° (11,1 mm) END-OF- DEFLECTOR BOSS ArreeN11111 TOP -OF- DEFLECTOR 1 -5/8° (41,3 mm) 2 -1/4° (57,2 mm) 7/16° (11,1 mm) H- NOMINAL MAKE -IN CENTERLINE OF WATERWAY ESCUTCHEON PLATE SEATING SURFACE I 7;1 ! �� STYLE 20 WRENCH FLATS 1/2° NPT RECESSED ESCUTCHEON • • • • • •••• • •RRc ESSED ••• • • •• • • •• • • •• • • •••• FIGURE 1 SERIES LFII (TY1334) RESIDENTIAL HORIZONTAL SIDEWALL AND RECESSED HORIZONTAL SIDEWALL SPRMN LE ?S •• •• • • • • •• •••• • • • •• • 2 -7/8° DIA. (73,0 mm) • TOP -OF- CLOSURE DEFLECTOR a\ 7/16° (11,1 mm) MOUNTING PLATE END -OF- DEFLECTOR BOSS 1-3/8" (34,9 mm) 1 -1/8° (28,6 mm) MOUNTING SURFACE 7/1611/8° (11,1 ±3,2 mm) FACE OF SPRINKLER FITTING 1/8° (3,2 mm) 1/2° (12,7 mm) 1/4° (6,4 mm) 2 -7/8 DIA. (73,0 mm) 2 -1/4 DIA. (57,2 mm) FIGURE 2 STYLE 20 RECESSED ESCUTCHEON FOR USE WITH THE SERIES LFII (TY1334) RESIDENTIAL HORIZONTAL SIDEWALL SPRINKLER • •••• • • • • WREDICH DECESS • (END°A° USED FOR TY1334) WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 4 W -TYPE 7 RECESSED SPRINKLER WRENCH • • • • . • • • •••• • • •• • • TFP410 Page 3 of 8 Technical Data Approvals: UL and C -UL Listed. NYC Approved under MEA 44 -03 -E. Maximum Working Pressure: 175 psi (12,1 bar) Discharge Coefficient: K = 4.2 GPM/psi (60,5 LPM/bar / Temperature Rating: 155 °F /68 °C or 175 °F /79 °C Finishes: White Polyester Coated, Chrome Plated, or Natural Brass Physical Characteristics: Frame Brass Button Bronze Sealing Assembly Beryllium Nickel w/Teflont Bulb 3 mm dia. Glass Compression Screw Bronze Deflector Copper tDupont Registered Trademark Operation The glass Bulb contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass Bulb allowing the sprinkler to activate and flow water. Design Criteria The Series LFII (TY1334) Residential Horizontal Sidewall Sprinklers are UL and C -UL Listed for installation in ac- cordance with the following criteria. NOTE When conditions exist that are outside the scope of the provided criteria, refer to the Residential Sprinkler Design Guide TFP490 for the manufacturer's recommendations that may be accept- able to the local Authority Having Ju- risdiction. System Type. Only wet pipe systems may be utilized. Hydraulic Design. The minimum re- quired sprinkler flow rate for systems designed to NFPA 13D or NFPA 13R are given in Table A, B, C, and D as a function of temperature rating and the maximum allowable coverage areas. The sprinkler flow rate is the minimum required discharge from each of the total number of "design sprinklers" as specified in NFPA 13D or NFPA 13R. For systems designed to NFPA 13, the number of design sprinklers is to be the four most hydraulically demanding sprinklers. The minimum required dis- charge from each of the four sprinklers is to be the greater of the following: • The flow rates given in Tables A, B, C, and D for NFPA 13D and 13R as a function of temperature rating and the maximum allowable coverage area. • A minimum discharge of 0.1 gpm /sq. ft. over the "design area" comprised of the four most hydraulically de- manding sprinklers for the actual coverage areas being protected by the four sprinklers. Obstruction To Water Distribution. Locations of sprinklers are to be in accordance with the obstruction rules of NFPA 13 for residential sprinklers. Operational Sensitivity. The sprin- klers are to be installed with an end -of- deflector -boss to wall distance of 1- 3/8 to 6 inches or in the recessed po- sition using only the Style 20 Re- cessed Escutcheon as shown in Figure 2. In addition the top-of- deflector -to -ceil- ing distance is to be within the range (Ref. Table A, B, C, or D) being hydrau- lically calculated. Sprinkler Spacing. The minimum spacing between sprinklers is 8 feet (2,4 m). The maximum spacing be- tween sprinklers cannot exceed the width of the coverage area (Ref. Table A) being hydraulically calculated (e.g., maximum 12 feet for a 12 ft. x 12 ft. coverage area, or 16 feet for a 16 ft. x 20 ft. coverage area). Installation The Series LFII (TY1334) must be in- stalled in accordance with the follow- ing instructions: NOTES Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm). A leak tight 1/2 inch NPT sprinkler joint should be obtained with a torque of 7 to 14 ft.lbs. (9,5 to 19,0 Nm). A maxi- mum of 21 ft.lbs. (28,5 Nm) of torque is to be used to install sprinklers. Higher levels of torque may distort the sprinkler inlet with consequent leak- age or impairment of the sprinkler. Do not attempt to compensate for in- sufficient adjustment in an Escutcheon Plate by under- or over - tightening the Sprinkler. Readjust the position of the sprinkler fitting to suit. The Series LFII Horizontal Sidewall Sprinklers must be installed in ac- cordance with the following instruc- tions. Step 1. Horizontal sidewall sprinklers are to be installed in the horizontal position with their centerline of water- way perpendicular to the back wall and parallel to the ceiling. The word "TOP" on the Deflector is to facG>;c» ards the ceiling wit the front et %9L the De- flector pailleI•to.he ceiling �• • Step 2. Wii,11, pipe thread stattnt ap- plied to th igag threads, h qrpd tighter the sprinkler jr2t2 the sprin kre; fitting. • Step 3. T?gagg the spCinitlin fhto thg • •, sprinkler fjttio�qq onlylhe W -Type • 6 Sprinkler 7ivrer ch (Ref. figure 3). With refergficefo Figure 1,'the1N- Typ8 • 6 SprinkletAN h is to be•applied to •• the wrencin flas.. •••• The Serie$ LFrI ecessdtrflbrizont4 Sidewall Sprinklers mget be installed in accordance with the•foflowing in- structions. Step A. Recessed horizontal sidewall sprinklers are to be installed in the horizontal position with their centerline of waterway perpendicular to the back wall and parallel to the ceiling. The word "TOP" on the Deflector is to face towards the ceiling. Step B. After installing the Style 20 Mounting Plate over the sprinkler threads and with pipe thread sealant applied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step C. Tighten the sprinkler into the sprinkler fitting using only the W -Type 7 Recessed Sprinkler Wrench (Ref. Figure 4). With reference to Figure 1, the W -Type 7 Recessed Sprinkler Wrench is to be applied to the sprinkler wrench flats. Step C. After the wall has been in- stalled or the finish coat has been ap- plied, slide on the Style 20 Closure over the Series LFII Sprinkler and push the Closure over the Mounting Plate until its flange comes in contact with the wall. (Continued on Page 8) • • • • • • Page 4 of 8 TFP410 ELEVATION •••• Maximum Coverage Area (a) Width x Length 04 Ft. x Ft. (m x m) 12 x 12 (3,7 x 3,7) 14 x 14 (4,3 x 4,3) 16 x 16 (4,9 x 4,9) 16 x 18 (4,9 x 5,5) 16 x 20 (4,9 x 6,1) Maximum Spacing Ft. (m) 12 (3,7) 14 (4,3) 16 ( 16 (4,9) 16 (4,9) • •••• • • • Minimum Flow (c) and Residual Pressure• • • • •• • • • • Top-Of-Deflector- To- Ceiling: 4 to 6 Inches (100 to 150 mm) 155 °F /68 °C 12 GPM (45,4 LPM) 8.2 psi (0,57 bar) 14 GPM (53,0 LPM) 11.1 psi (0,77 bar) 16 GPM (60,6 LPM) 14.5 psi (1,00 bar) 19 GPM (71,9 LPM) 20.5 psi (1,41 bar) 23 GPM (87,1 LPM) 30.0 psi (2,07 bar) 175FF79°C 12 GPM (45,4 LPM) 8.2 psi (0,57 bar) 16 GPM (60,6 LPM) 14.5 psi (1,00 bar) 16 GPM (60,6 LPM) 14.5 psi (1,00 bar) 19 GPM (71,9 LPM) 20.5 psi (1,41 bar) 23 GPM (87,1 LPM) 30.0 psi (2,07 bar) Top- Of- Deilqcarr To- Ceiling:. 6 to 12 Inchea.QQ0 to 150m) • • • • • • • • 155 °F /68 °C • • •• 13 GPM (49,2 LP14). 9.6 psi (0,66 bai3 17 GPM (64,3 LPVI) 16.4 psi (1,13be) _ 18 GPM (68,1 LPM) 18.4 psi (1,27 bar) 21 GPM (79,5 LPM) 25.0 psi (1,72 bar) 26 GPM (98,4 LPM) 38.3 psi (2,64 bar) • • •• • • 175° 9p ▪ • •• • ..1$ GPM (49,2.LPM) • 9.6 psi (Q 66.bar) .18 GPM t6,8.1.I.PM) • X8.4 psi (1,27 bar) 18 GPM f68 + 1•LIV) 18.4 psi (1,27 bar) 21 GPM (79,5 LPM) 25.0 psi (1,72 bar) 26 GPM (98,4 LPM) 38.3 psi (2,64 bar) (a) For coverage area dimensions less than or between those indicated, it is necessary to use the minimum required flow for the next highest coverage area for which hydraulic design criteria are stated. (b) Width (backwall where sprinkler is located) x Length (horizontal throw of sprinkler). (c) Requirement is based on minimum flow in GPM (LPM) from each sprinkler. The associated residual pressures are calculated using the nominal K- factor. Refer to Hydraulic Design Criteria Section for details. (d) Sidewall sprinklers, where installed under a ceiling with a slope greater than 0 inch rise for a 12 inch run to a slope up to 2 inch rise for 12 inch run, must be located per one of the following: • Locate the sprinklers at the high point of the slope and positioned to discharge down the slope. • Locate the sprinklers along the slope and positioned to discharge across the slope. TABLE A NFPA 13D AND NFPA 13R HYDRAULIC DESIGN CRITERIA FOR THE SERIES LFII (TY1334) RESIDENTIAL HORIZONTAL SIDEWALL AND RECESSED HORIZONTAL SIDEWALL SPRINKLERS FOR HORIZONTAL CEILING (Maximum 2 Inch Rise for 12 Inch Run) • • a • Maximum Coverage Area 41 Width x Length (b) FL x Ft. (m x m) Maximum Spacing Ft. (m) • • •••• • • • Minimum Flow lc) and Residual Pressure • • • • • • • • • (I) Two sprinkler design with the sprinklers at the high point of the sidplB tiposItloneo • to discharge down the slope. • •••• • • • •••••• • •••• •••• • Top -Of- Deflector- To- Ceiling: 4 to 6 Inches (100 to 150 mm) Top-0f- Defle.Rort To- Ceilit4 • • 6 to 12 Incluroliftto 300 mm) • _ • • 155 °F /68 °C 175 °F /79 °C 155 °F /68 °C • •, • • • • • 175 °F /H 1 • • ••• 12 x 12 (3,7 x 3,7) 12 (3,7) 1 12 GPM (45,4 LPM) 8.2 psi (0,57 bar) I 12 GPM (45,4 LPM) 82 psi (0,57 bar) I 13 GPM (49,2 LPM) 9.6 psi (0,66 bar) I 13 GPM '49,2 L°PM) 9.6 psi (0,66 bar) 14 x 14 (4,3 x 4,3) 14 (4,3) I 14 GPM (53,0 LPM) 11.1 psi (0,77 bar) I 14 GPM (53,0 LPM) 11.1 psi (0,77 bar) I 17 GPM (64.3 LPM) 16.4 psi (1,13 bar) 1 17 GPM (64.3 LPM) 16.4 psi (1,13 bar) 16 x 16 (4,9 x 4,9) 16 (4,9) 1 16 GPM (60,6 LPM) 14.5 psi (1,00 bar) 1 ` 16 GPM (60,6 LPM) 14.5 psi (1,00 bar) I 18 GPM (68,1 LPM) 18.4 psi (1,27 bar) 1 18 GPM (68,1 LPM) 18.4 psi (1,27 bar) 16 x 18 (4,9 x 5,5) 16 (4,9) I 19 GPM (71,9 LPM) 20.5 psi (1,41 bar) I 19 GPM (71,9 LPM) 20.5 psi (1,41 bar) I 21 GPM (79,5 LPM) 25.0 psi (1,72 bar) I 21 GPM (79,5 LPM) 25.0 psi (1,72 bar) 16 x 20 (4,9 x 6,1) 16 (4,9) 1 24 GPM (90,8 LPM) 32.7 psi (2,25 bar) I 24 GPM (90,8 LPM) 32.7 psi (2,25 bar) I 26 GPM (98,4 LPM) 38.3 psi (2,64 bar) 1 26 GPM (98,4 LPM) 38.3 psi (2,64 bar) TFP410 Page 5 of 8 12" 8" MAXIMUM ELEVATION • (a) For coverage area dimensions Tess than or between those indicated, it is necessary to use the minimum required flow for the next highest coverage area for which hydraulic design criteria are stated. (b) Width (badman where sprinkler is located) x Length (horizontal throw of sprinkler). (c) Requirement is based on minimum flow in GPM (LPM) from each sprinkler. The associated residual pressures are calculated using the nominal K- factor. Refer to Hydraulic Design Criteria Section for details.. TABLE B NFPA 13D AND NFPA 13R HYDRAULIC DESIGN CRITERIA FOR THE SERIES LFII (TY1334) RESIDENTIAL HORIZONTAL SIDEWALL AND RECESSED HORIZONTAL SIDEWALL SPRINKLERS FOR SPRINKLERS AT THE HIGH POINT OF THE SLOPE AND DISCHARGING DOWN THE SLOPE (Greater Than 2 Inch Rise for 12 Inch Run Up To 8 Inch Rise for 12 Inch Run) • • • • • 1 •••• • • 1•• •• •� • • Page 6 of 8 TFP410 ELEVATION 12" 4" MAXIMUM •.•• • • Maximum Coverage Area (e) Width x Length (b) (m x m) Maximum Spacing Ft. (m) • • •••• • • • Minimum Flow (c) and Residual Pressure " • .' : •: (II) Two sprinkler design with the sprinklers located along the slope ana'posiaoned to • ' discharge across the slope. • (III) Three sprinkler design when there are more than two sprinklers )a II t6thpartme d• . with the sprinklers located along the slope,and positioned to disctfa?Vacross t$ie slope. •••• • • • • • Top -Of- Deflector- To- Ceiling: 4 to 6 Inches (100 to 150 mm) . • • • Top-Of- Deflector- fo- Ceiling: 6 to 12 Inchee (t40 300 mm) • 155 °F /68 °C 175 °F /79 °C 155 °F /68 °C • .. • • • ; 175 °F /i9 V , • • • 12 x 12 (3,7 x 3,7) 12 (3,7) II 16 GPM (60,6 LPM) 14.5 psi (1,00 bar) II 16 GPM (60,6 LPM) 14.5 psi (1,00 bar) II 18 GPM (68,1 LPM) 18.4 psi (1,27 bar) II 18 GPM r6 %,1 L1 18.4 psi (1,27 bar) 14 x 14 (4,3 x 4,3) 14 (4,3) II 16 GPM (60,6 LPM) 14.5 psi (1,00 bar) I1 16 GPM (60,6 LPM) 14.5 psi (1,00 bar) II 18 GPM (68,1 LPM) 18.4 psi (1,27 bar) 11 18 GPM (68,1 LPM) 18.4 psi (1,27 bar) 16 x 16 (4,9 x 4,9) 16 (4,9) 11 16 GPM (60,6 LPM) 14.5 psi (1,00 bar) II 16 GPM (60,6 LPM) 14.5 psi (1,00 bar) i ll 18 GPM (68,1 LPM) 18.4 psi (1,27 bar) II 18 GPM (68,1 LPM) 18.4 psi (1,27 bar) 16 x 18 (4,9 x 5,5) 16 (4,9) II 22 GPM (83,3 LPM) 27.4 psi (1,89 bar) II 22 GPM (83,3 LPM) 27.4 psi (1,89 bar) 11 22 GPM (83,3 LPM) 27.4 psi (1,89 bar) II 22 GPM (83,3 LPM) 27.4 psi (1,89 bar) 16 x 20 (4,9 x 6,1) 16 (4,9) III 23 GPM (87,1 LPM) 30.0 psi (2,07 bar) III 23 GPM (87,1 LPM) 30.0 psi (2,07 bar) III 26 GPM (98,4 LPM) 38.3 psi (2,64 bar) III 26 GPM (98,4 LPM) 38.3 psi (2,64 bar) (a) For coverage area dimensions Tess than or between those indicated, it is necessary to use the minimum required flow for the next highest coverage area for which hydraulic design criteria are stated. (b) Width (backwall where sprinkler is located) x Length (horizontal throw of sprinkler). (c) Requirement is based on minimum flow in GPM (LPM) from each sprinkler. The associated residual pressures are calculated using the nominal K- factor. Refer to Hydraulic Design Criteria Section for details.. TABLE C NFPA 13D AND NFPA 13R HYDRAULIC DESIGN CRITERIA FOR THE SERIES LFII (TY1334) RESIDENTIAL HORIZONTAL SIDEWALL AND RECESSED HORIZONTAL S/DEWALL SPRINKLERS FOR SPRINKLERS LOCATED ALONG A SLOPE AND DISCHARGING ACROSS THE SLOPE (Greater Than 2 Inch Rise for 12 Inch Run Up To 4 Inch Rise for 12 Inch Run) Page 6 of 8 TFP410 TFP410 Page 7 of 8 • • •.•• • • •••• • • • •. 12" 8" MAXIMUM ••.• - . ELEVATION Maximum Coverage Area (a) Width x Length (bl FLxFt. (m x m) Maximum Spacing Ft. (m) • • •••• • • • • Minimum Flow (c) and Residual Pressure • • • • • • • (III) Three sprinkler design when there are more than two sprinklers 11113 tDfhpartment• lhd • with the sprinklers located along the slope,and posifloned to dlsdtfftgOicross the slope. •••• • • • • • • • • •••• • • • •••• Top -Of- Deflector- To- Ceiling: • • • • 4 to 6 Inches (100 to 150 mm) • • • 155 °F /68 °C • • 17J°F / °0 • • • • 12 x 12 (3,7 x 3,7) 12 (3,7) Ill 16 GPM (60,6 LPM) 14.5 psi (1,00 bar) I11 16 GPM (60,6 LPM) •' • 14.5 psi (1,00 bar) 14 x 14 (4,3 x 4,3) 14 (4,3) III 16 GPM (60,6 LPM) 14.5 psi (1,00 bar) III 16 GPM (60,6 LPM) 14.5 psi (1,00 bar) 16 x 16 (4,9 x 4,9) 16 (4,9) III 16 GPM (60,6 LPM) 14.5 psi (1,00 bar) Ill 16 GPM (60,6 LPM) 14.5 psi (1,00 bar) 16x18 (4,9 x 5,5) 16 (4,9) N/A N/A 16 x 20 (4,9 x 6,1) 16 (4,9) N/A N/A (a) For coverage area dimensions less than or between those indicated, it is necessary to use the minimum required flow for the next highest coverage area for which hydraulic design criteria are stated. (b) Width (backwall where sprinkler is located) x Length (horizontal throw of sprinkler). (c) Requirement is based on minimum flow in GPM (LPM) from each sprinkler. The associated residual pressures are calculated using the nominal K- factor. Refer to Hydraulic Design Criteria Section for details.. TABLE D NFPA 13D AND NFPA 13R HYDRAULIC DESIGN CRITERIA FOR THE SERIES LFII (TY1334) RESIDENTIAL HORIZONTAL SIDEWALL AND RECESSED HORIZONTAL SIDEWALL SPRINKLERS FOR SPRINKLERS LOCATED ALONG A SLOPE AND DISCHARGING ACROSS THE SLOPE (Greater Than 4 Inch Rise for 12 Inch Run Up To 8 Inch Rise for 12 Inch Run) TFP410 Page 7 of 8 • • •.•• • • •••• • • • •. Page 8 of 8 TFP410 Care and Maintenance The Series LFII (TY1334) must be maintained and serviced in accord- ance with the following instructions: NOTES Absence of an Escutcheon Plate may delay the sprinkler operation in a fire situation. Before closing a fire protection system main control valve for maintenance work on the fire protection system which it controls, permission to shut down the affected fire protection sys- tem must be obtained from the proper authorities and all personnel who may be affected by this action must be no- tified. Sprinklers which are found to be leak- ing or exhibiting visible signs of corro- sion must be replaced. Automatic sprinklers must never be painted, plated, coated, or otherwise altered after leaving the factory. Modi- fied sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers - before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be re- placed. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section). The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. The in- stalling contractor or sprinkler manu- facturer should be contacted relative to any questions. NOTE The owner must assure that the sprin- klers are not used for hanging of any objects and that the sprinklers are only cleaned by means of gently dusting with a feather duster; otherwise, non - operation in the event of a fire or inad- vertent operation may result. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and /or national codes. Limited Warranty Products manufactured by Tyco Fire Products are warranted solely to the original Buyer for ten (10) years against defects in material and work- manship when paid for and properly installed and maintained under normal use and service. This warranty will ex- pire ten (10) years from date of ship- ment by Tyco Fire Products. No war- ranty is given for products or components manufactured by compa- nies not affiliated by ownership with Tyco Fire Products or for products and components which have been subject to misuse, improper installation, corro- sion, or which have not been installed, maintained, modified or repaired in ac- cordance with applicable Standards of the National Fire Protection Associa- tion, and/or the standards of any other Authorities Having Jurisdiction. Mate- rials found by Tyco Fire Products to be defective shall be either repaired or replaced, at Tyco Fire Products' sole option. Tyco Fire Products neither as- sumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of products. Tyco Fire Products shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer's representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CON- TRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THE- ORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LABOR CHARGES, RE- GARDLESS OF WHETHER TYCO FIRE PRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENT SHALL TYCO FIRE PRODUCTS' LI- ABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. THE FOREGOING WARRANTY IS MADE IN LIEU OF ANY AND ALL OTHER WARRANTIES EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY AND FIT- .NESS FOR A PARTICULAR PUR- POSE, Ordering Procedure TYCO FIRE PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 When placing an order, indicate the full product name. Contact your local dis- tributor for availability.. Sprinkler Assembly: Series LFII (TY1334), K =4.2, Residen- tial Horizontal Sidewall Sprinkler with (specify) temperature rating and (specify) finish, P/N (specify). 155 °F /68 °C or Chrome Plated P/N 51- 211 -9 -155 155'F/68°C White Polyester P/45-1 1 -4 -155 155 °F /68 °C • • White • • •••• (RAL9010) • P415j V -3 -155 155F/68°C • • • Natural Bradt• • • • PR051 -2I1 -1 -155 175'F/79°C of • • • Chrome Plated P/N 51- 211 -9 -175. 175 °F /79 °C • • • • • • • • • White Polyester. . • 1/N'5442 ?1-4 -175 175'FT79°C White "" (RAL9010) a ..• • 4.51 -221 -3 -175• 175'F/79°C Natural Brass... . • P/N 5�- 211 -1 -175 • ..•• *Eastern Hemisphere sales "qp y..' • • • Recessed Escutcheon :•� Specify: Style 20 Recessed Escutch- eon with (specify) finish, P/N (specify). 1/2° (15 mm) Style 20 Chrome Plated P/N 56 -705 -9 -010 1/2° (15 mm) Style 20 White Color Coated P/N 56 -705 -4 -010 1/2° (15 mm) Style 20 White (RAL9010)' P/N 56- 705 -3-010 1/2° (15 mm) Style 20 Bright Brass Coated P/N 56 -705 -2 -010 *Eastern Hemisphere sales only. Sprinkler Wrench: Specify: W -Type 6 Sprinkler Wrench, P/N 56- 000 -6 -387. Specify: W -Type 7 Sprinkler Wrench, P/N 56- 850 -4 -001. • • • • • • •� • • tLICIJI Fire &Building Products Technical Services: Tel: (800) 381 -9312 / Fax: (800) 791 -5500 Aft EEIVTRAL Customer Service/Sales: Tel: (215) 362 -0700 / (800) 523 -6512 Fax: (215) 362 -5385 Series TY SA, and 8 0 Kw Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage General Description The Series TY-B, 2.8, 5.6, and 8.0 K- factor, Upright and Pendent Sprin- klers described in this data sheet are standard response - standard cover- age, decorative 5 mm glass bulb type spray sprinklers designed for use in light, ordinary, or extra hazard, com- mercial occupancies such as banks, hotels, shopping malls, factories, refin- eries, chemical plants, etc. The recessed version of the Series TY-B Pendent Sprinkler, where appli- cable, is intended for use in areas with a finished ceiling. It uses a two -piece Style 10 (1/2 inch NPT) or Style40 (3/4 Inch NPT) Recessed Escutcheon. The Recessed Escutcheon provides 1/2 inch (12,7 mrn) of recessed adjust- ment or up to 3/4 inch (19,1 mm) of total adjustment from the flush pen- dent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Corrosion resistant coatings, where applicable, are utilized to extend the life of copper ahoy sprinklers beyond that which would otherwise be ob- tained when exposed to corrosive at- mospheres. Although corrosion resis- tant coated sprinklers have passed the standard corrosion tests of the appli- cable approval agencies, the testing is IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handing and in- stallation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 8 not representative of all possible cor- rosive atmospheres. Conseajuentiy, rt is recommended that the end user be consulted with respect to the suitability of these _coatingss for any given corro- sive The effects of ambi- ent temperature, concentration of cherntoals, and gas/chemical velocity, should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. An intermediate level version of the Series TY-B Pendent Sprinkler can be obtained: by utilizing the Series TY-B Pendent Sprinkler in combination with the Model S2 Shield. WARNINGS The Series TY-B Sprinklers described herein must be installed and main- tained in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association, in addition to the standards of any other authorities hav- ing/urisdiction. Failure to do so may impair the performance of these de- vices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions, Model/Sprinlder Ident ficatiion numbers TY1151 - TY1251 - TY3151- TY3251 - TY4151 - TY4251 - T1(4851 TY4951 - Upright 2.BK,112 "NPT Pendent 2.8K, ti2 "NPT Upright . 5-6K,1 /2°NPT Pendent 5.6 1/2 "1 Upright 8.tiK, 3/4 "NPT Pendent 8.0K, 3/4 "NPT Upright 8 OK,1/2"NPT Pendent 8.0K,1/2 "NPT JULY, 2004 TFP151 Page 2 of 8 ' • • T Pf Si 1 - Frame 2 - Button ESCUTCHEON 7/16' 01,1 mm) PLATE SEATING ° •• NOMINAL SSU* SURFACE t�MT MAKE -IN DEFLECTOR 2-1/4' (57,2 mm) 3 - Sealing 4 - Bulb Assembly 5 -Compression Screw SSP DEFLECTOR PENDENT UPRIGHT 6 - Deflector * Temperature rating is indicated on deflec ooror adjacent to 7 - Bushing orifice Seat on frame. • • • • • • • ••• * thread connections' pr1S® 7/1 can be'provided str‘ • special request. 0 000• • 0 • • • 0000 • •• CROSS SECTION • • FIGURE STANDARD RESPONSE SERIES ma UPRIGHT ' 151) AND PENDENT (TY12W'SPRIM (I 8 K FACTOR, 1.12 INCH NPT • • • 6 5 4 2 3 1 7 •• • • ..•• • ••• ••• • SOO ESCUTCHEON 7/16' (11,1 mm) PLATE SEATING ** NOMINAL SURFACE NPT 1N 1 2 -3/16° (55,6 mm) 1 1 -1/2° (38,1 mm) SSP DEFLECTOR PENDENT 1 - Frame 3 - Sealing 2 - Button Assembly 4-Bulb 5 - Compression Screw STYLE 10 RECESSED ESCUTCHEON WRENCH FLATS 2 -7/8° (73,0 tarn) DIA. — 4 1 RECESSED PENDENT 6 - Deflector SSU DEFLECTOR • • •• • •••• • ••• • • • •• • • ••• • CROSS SECTION * Temperature rating is indicated on deflector or adjacent to orifice seat on frame. * thread connections per ISO 7/1 can be provided on special request. FIGURE 2 STANDARD RESPONSE SERIES TY-B UPRIGHT (TY3151) AND PENDENT (TY3251) SPRINKLERS 5.6 K- FACTOR, 112 INCH NPT 1•• r • t•• • 1•• • r• • • • •• • TFP151 ESCUTCHEON PLATE SEATING SURFACE 2- 5/16° (58,7 mm) 1 -9/16° (3 mm) SSP DEFLECTOR 1/2° (12,7 mm) 3/4° ** NOMINAL MIT MAKE-IN STYLE 40 RECESSED ESCUTCHEON WRENCH RATS 2 -7/8° (7$,0 mm) [?IA PENDENT RECESSED PENDENT FIGURE SSU DEFLECTOR 3/4° UPRIGHT 1/2 (12,7 mm) NOMINAL MAKE -IN 2 -1/4° (57,2 mm) •••• • • CROSS SECTION •. • • • • •. • • • • • • 1 - Frame 3 4 - Bulb 6 - Deflector * Temperature rating is incUeat'c5n detect8Por atijacent't8 2 - Button Assembly 5 - Compression 7 Ejection orifice seat on frame, • : • • Screw Spring **Pipe thread connectionsitto 7/1 cm b pivided opt special request. . • . • • • • • • • • ••• •••• STANDARD RESPONSE SERIES T Y -Q UPRIGh T (TY4151) AND PENDENT (TW2�bi) SPRINkCLERd 11.0 K- FACTOR, 314 INCH NPT • .• • .•• • Page 3ofS • 1 - Frame 2 - Button ESCUTCHEON 7/16° (1'1,1 mm) PLATESEAT G NOMINAL SSU SURFACE I /T MAKE -IN DEFLECTOR 2 -1/4° (57,2 mm) 1-9/16° (39,7 min) 3 - Sealing 4-Bub Assembly 5 - Compression Salem WRENCH FLATS SSP DEFLECTOR PENDENT UPRIGHT 6- Deflector • - . •• • 23/16° (55,6 mm) CROSS SECTION * • • • • • •• • FIGURE 4 STANDARD RESPONSE SERIES TY 0 UPRIGHT (7Y4851) AND .PENDENT (TY4951) SPRINKLERS 8,e KKFACTOR, 1,V INCH NNPT * Temperature rating is indicated on deflector or adjacent to orifice seat-on frame. **Pipe thread connections per ISO 7/1 can be provided on special request ••• ••• • ••• • • • • •• ..• • •• .•. • ••• • Page 4 of 8 TABLE A LABORATORY LISTINGS AND APPROVALS ISM Si NOTES: 1. Listed by Underwriters Laboratories, Inc. (UL). 2. Listed by Underwriters Laboratories, Inc. for use in Canada (C -UL). 3. Approved by Factory Mutual Research Corporation (FM). 4. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 007k103). 5. Approved by the City of New York under MEA 354 -01 -E. 6. VdS Approved (For details contact Tyco Fire & Building Products, Enschede, Netherlands, Tel. 31-53-428-4444/Fax 31- 53- 428 - 3377). 7. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/05). 8. Where Polyester Coated, Lead Coated, Wax Coated, and Wax over Lead Coated Sprinklers are noted to be UL and C -UL Listed, the sprinklers are UL and C-UL Listed as. Corrosion Resistant Sprinklers. Where Lead Coated, Wax Coated, and Wax over Lead Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as Corrosion Resistant Sprinklers. • Installed with Style 10 (1/2° NPT) or Style 40 (3/4° NPT) 3/4° Total Adjustment Recessed Escutcheon, as applicable. ..� 50 °F /66 °C Maximum Ceiling Temperature. Frame and deflector only. Listings and approvals apply to color (Special Order). N/A: Not Available SPRINKLER FINISH (See Note 8) K TYPE TEMP. BULB LIQUID NATURAL CHROME BRASS PLATED WHiI E*`* ° . YESTER LEAD COATED WAX COATED WAX OVER LEAD COATED 1i NPT 135 °F /57°C Orange 1, 2, 3 N/A PENDENT w and 155 Red 175°F/79°C Yellow UPRIGHT 200F/93°C Green (TY1151) 286F/141°C Bkte 360F/182°C Mauve 1, 2 5.6 P PENDENT (TY3251) and UPRIGHT (N3151) 135°F/57 °C Orange 1,2,3,4,5,6,7 1,2,3,5 1,2,3,5 4 ..:,2,3,5 • • .. • • 1 • • 155 ° F/68°C Red 175 °F /79 °C Yellow 200 °F /93 °C Green D avar.3'", 5 • Z'*. 3*31 , 286°F/141 286°F/141°C Blue • • • N/A • • _ 360F/182°C Mauve RECESSED PENDENT (Ty�1)* Figure 4 135 °F /57°C Orange 1, 2, 3, 4, 5 1, 2, 4, 5 . • • • •••••• • • • • N/A •• • • • • • • • • • • •••• ••• • • •• • • • . • • • • • ••• ' • ■ 155 ° F /68°C . Red 175°F/79°C Yellow 200 °F /93°0 G r e en 3/4° NPT PENDENT (TY4251) and UPRIGHT (TY4151) 135 °F /57 °C Orange 1, 2, 3, 4, 5, 6, 7 1,2,5 • • • • ' .. • • • • 1,2,3,5 •..• • • • • • • •.• •••• • :1,2,5 155 F /68°C Red 175 °F /79 °C Yellow 200 °F /93°C Green 286°F/141°C Blue 1",2", 3 ", 5" 1", 2", 5" 360°F /182 °C Mauve WA RECESSED PENDENT (TY4251)* Figure 5 135 °F /57°C Orange N/A 155 °F /68 °C Red 1, 2, 4, 5 175 °F179 °C Yellow 3, 200°F/93°C Green 8.0 1/2° NPT PENDENT (TY4951) and UPRIGHT (TY41) 135 °F /57°C Orange N/A • 155°F/68 °C Red 175 °F /79 °C Yellow 1, 2, 3, 5 200 °F /93°C Green 286°F/141°C Blue 360 °F /182 °C Mauve Page 4 of 8 TABLE A LABORATORY LISTINGS AND APPROVALS ISM Si NOTES: 1. Listed by Underwriters Laboratories, Inc. (UL). 2. Listed by Underwriters Laboratories, Inc. for use in Canada (C -UL). 3. Approved by Factory Mutual Research Corporation (FM). 4. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 007k103). 5. Approved by the City of New York under MEA 354 -01 -E. 6. VdS Approved (For details contact Tyco Fire & Building Products, Enschede, Netherlands, Tel. 31-53-428-4444/Fax 31- 53- 428 - 3377). 7. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/05). 8. Where Polyester Coated, Lead Coated, Wax Coated, and Wax over Lead Coated Sprinklers are noted to be UL and C -UL Listed, the sprinklers are UL and C-UL Listed as. Corrosion Resistant Sprinklers. Where Lead Coated, Wax Coated, and Wax over Lead Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as Corrosion Resistant Sprinklers. • Installed with Style 10 (1/2° NPT) or Style 40 (3/4° NPT) 3/4° Total Adjustment Recessed Escutcheon, as applicable. ..� 50 °F /66 °C Maximum Ceiling Temperature. Frame and deflector only. Listings and approvals apply to color (Special Order). N/A: Not Available Page 4 of 8 TABLE A LABORATORY LISTINGS AND APPROVALS TFP151 NOTES: 1. Listed by Underwriters Laboratories, Inc. (UL). 2. Listed by Underwriters Laboratories, Inc. for use in Canada (C -UL). 3. Approved by Factory Mutual Research Corporation (FM). 4. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 007k/03). 5. Approved by the City of New York under MEA 354 -01 -E. 6. VdS Approved (For details contact Tyco Fire & Building Products, Enschede, Netherlands, Tel. 31- 53- 428- 4444/Fax 31 -53 -428- 3377). 7. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/05). 8. Where Polyester Coated, Lead Coated, Wax Coated, and Wax over Lead Coated Sprinklers are noted to be UL and C -UL Listed, the sprinklers are UL and C -UL Listed as Corrosion Resistant Sprinklers. Where Lead Coated, Wax Coated, and Wax over Lead Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as Corrosion Resistant Sprinklers. * Installed with Style 10 (1/2° NPT) or Style 40 (3/4° NPT) 3/4° Total Adjustment Recessed Escutcheon, as applicable. ** 150 °F /66 °C Maximum Ceiling Temperature. * ** Frame and deflector only. Listings and approvals apply to color (Special Order). N /A: Not Available • • • •••• • • • ••• •• • • • • SPRINKLER FINISH (See Note 8) K TYPE TEMP. BULB NATURAL CHROME WHITE*** LEAD WAX WAX OVER LIQUID BRASS PLATED POLYESTER COATED COATED LEAD COATED 135 °F /57 °C Orange PENDENT 155 °F /68 °C Red 2.8 1 ) 1,2,3 WA 175 °F /79 °C Yellow 1/2° and NPT UPRIGHT 200 °F /93 °C Green (TY1151) 286 °F /141 °C Blue 360 °F /182 °C Mauve 1, 2 135 °F /57 °C Orange PENDENT 155 °F /68 °C Red (TY3251) 1,2,3,4,5,6,7 1,2,3,5 1,2,3,5 1,2,3,5 175 °F /79 °C Yellow and UPRIGHT 200 °F /93 °C Green • • • •••• • 5.6 (TY3151) 286 °F /141 °C Blue 1 ** 2"! 3**`5 ** 11;v 2 **, 5 ** 1/2" 360 °F /182 °C - Mauve • N/A " _ ' NPT 135 °F /57 °C Orange •••• • • • RECESSED 155 °F /68 °C Red •••• • • • • PENDENT (TY3251)* 1, 2, 3, 4, 5 1, 2, 4, 5 ".• • • "• • •• •• •• • 175"F/79°C Yellow 200 °F /93 °C Green Figure 4 PENDENT 135 °F /57 °C Orange • ' • ' • •••• • • • • • • • 155 °F /68 °C Red (TY4251) 1, 2, 5 1.8, • 10 2.5 i 175 °F /79 °C Yellow and 1, 2, 3, 4, 5, 6, 7 ' ' • •• • 8.0 UPRIGHT 200 °F /93 °C Green 3/4° (TY4151) 286 °F /141 °C Blue 1 * *,2 * *, 3 * *, 5 ** I 1 *" 2 ** 5 ** NPT 360 °F/182 °C Mauve N/A 135 °F /57 °C Orange RECESSED 155 °F /68 °C Red PENDENT 1, 2, 3, 4, 5 N/A 175 °F /79 °C Yellow (TY4251)• Figure 5 200 °F /93 °C Green 135 °F /57 °C Orange 8.0 4D.98 155 °F /68 °C Red 1/2" and 175 °F /79 °C Yellow 1, 2, 3, 5 N/A NPT UPRIGHT (TY4851) 200 °F /93 °C Green 286 °F /141 °C Blue 360 °F /182 °C Mauve Page 4 of 8 TABLE A LABORATORY LISTINGS AND APPROVALS TFP151 NOTES: 1. Listed by Underwriters Laboratories, Inc. (UL). 2. Listed by Underwriters Laboratories, Inc. for use in Canada (C -UL). 3. Approved by Factory Mutual Research Corporation (FM). 4. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 007k/03). 5. Approved by the City of New York under MEA 354 -01 -E. 6. VdS Approved (For details contact Tyco Fire & Building Products, Enschede, Netherlands, Tel. 31- 53- 428- 4444/Fax 31 -53 -428- 3377). 7. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/05). 8. Where Polyester Coated, Lead Coated, Wax Coated, and Wax over Lead Coated Sprinklers are noted to be UL and C -UL Listed, the sprinklers are UL and C -UL Listed as Corrosion Resistant Sprinklers. Where Lead Coated, Wax Coated, and Wax over Lead Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as Corrosion Resistant Sprinklers. * Installed with Style 10 (1/2° NPT) or Style 40 (3/4° NPT) 3/4° Total Adjustment Recessed Escutcheon, as applicable. ** 150 °F /66 °C Maximum Ceiling Temperature. * ** Frame and deflector only. Listings and approvals apply to color (Special Order). N /A: Not Available • • • •••• • • • ••• •• • • • • TFP151 2-7/8° DIA. (73,0 mm) 5/811/4° (15,9±6,4 mm) FACE OF SPRINKLER FITTING MOUNTING SURFACE CLOSURE SERIES TY-B 2 -1/4° DIA. (57,2 mm) 3/4° (19,1 mm) 1/4" (6,4 mm) MOUNTING PLATE 1/8" (3,2 mm) 1 1-1/4" (31,8 mm) 3/4° (19,1 mm) FIGURE 5 SERIES TY-B RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO -PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 5.6 K- FACTOR, 1/2 INCH NPT 5/8±1/4" (15,9±6,4 mm) FACE OF SPRINKLER FITTING MOUNTING SURFACE CLOSURE 2 -7/8° DIA. (73,0 mm) 2-1/4" DIA. (57,2 mm) SERIES TY-B 3/4" (19,1 mm) 1/4" (6,4 mm) MOUNTING PLATE 1/8" (3,2 mm) 1 -5/16° (33,3 mm) 13/16° (20,6 mm) FIGURE 6 SERIES TY-B RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO -PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON 8.0 K- FACTOR, 3/4 INCH NPT Page 5 of 8 WRENCH RECESS (END °B° USED FOR 3/4° NPT MODELS) WRENCH RECESS (END °A° USED FOR 1/2° NPT MODELS) FIGURE 7 W -TYPE 6 SPRINKLER WRENCH • WRENCH • ••• • • • RECESS •• • • PUSI- 'WRENCH• • • INTO ENSURE • ENGAGEMENt WITH SPRINK6ER : • WRENCHING AREA • FIGURE 8 W -TYPE 7 RECESSED SPRINKLER WRENCH • • i • • • • •••• • • •••• • • • Page 6 of 8 TfP1S1 Tecihnical Data Approvals UL and C -UL Listed. FM, LPCB, VdS, and NYC Approved. (Refer to Table A for complete approval information including corrosion resis- tant status.) Maximum Working Pressure 175 psi (12,1 bar) Discharge Coefficient K = 2.8 GPM /psl (40,3 LPM/bar K = 5.6 GPM/psi (80,6 LPM/bar K = 8.0 GPM/psilr (115,2 LPM/barlI Temperature Ratings Refer to Table A Finishes Sprinkler: Reessed Escutcheon: White Coated, Chrome Plated, or Brass Plated Physical Characteristics Frame Bronze Button Brass/Copper Sealing Assembly Beryllium Nickel w/Teflont Bulb Glass Compression Screw Bronze Deflector Copper Bushing (K =2.8) Bronze Operation The glass Bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached,,the fluid expands sufficiently to shatter the glass Bulb, allowing the sprinkler to activate and water to flow. Design Criteria The Series TY-B Pendent and Upright Sprinklers are intended for fire protec- tion systems designed in accordance with the standard Installation rules rec- ognized by the applicable Listing or Approval agency (e.g., UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM's Loss Prevention Data Sheets). Only the Style 10 or 40 Recessed Escutcheon, as applicable, is to be used for recessed pendent installations. Installation The Series TY-B Sprinklers must be installed in accordance with the follow- ing instructions: NOTES Dv not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F/57°C to 3/32 inch (2,4 mm) for the 360 temperature ratings. A leak tight 1/2 inch NPT sprinklerjoint should be obtained with a torque of 7 to 14 ftlbs. (9,5 to 19,0 Nm). A maxi= mum of 21 ft. lbs. (28,5 Nm) of torque may be used. to inStali sprinklers .with 1/2 NPT connections. A leak tight 3/4 inch NPT sprinkler joint should be ob- tained with a torque of 10 to 20 ft lbs. (13,4 to 26,8 Nm). A maximum of 30 ft.lbs. (40,7 Nm) of torque is to be used to install sprinklers with 3/4 NPT con - nectionst Higher levels of torque may distort the sprinkler inlet and cause leakage or impairment of the sprinkler. Do not attempt to make -up for insuffi- cient adjustment in the escutcheon plate by under- or over - tightening the sprinkler. Readjust the position of the sprinkler fitting to suit The Series TY -B Pendent and Up- right Sprinklers must be installed in accordance with the following instruc- tions. Step 1. Pendent sprinklers are to be installed in the pendent position, and upright sprinklers are to be installed in the upright position. Step 2: With pipe thread sealant ap- plied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W -Type 6 Sprinkler Wrench. (Ref. Figure 7), except that an 8 or 10 inch adjustable Crescent wrench is to be used for wax coated sprinklers. With reference to Figures '1 2, 3, and 4 `the W -Type 7 Sprinkler Wrench or the adjustable Crescent wrench, as applicable is to be applied to the wrench flats. When installing wax coated sprinklers with the adjustable Crescent wrench, additional care needs to be exercised to prevent darnage to the Waal coating on the sprinkler wrench flats or frame arms and, consequently, exposure of bare metal to the corrosive environ- ment. The Jaws of the wrench should be opened sufficiently wide to pass over the wrench flats without damag- ing the wax coating. Before wrench tightening the sprinkler, the jaws of the wrench are to be adjusted to Just con- tact the sprinkler wrench flats. After wrench tightening the sprinkler, loosen the wrench jaws before removing the wrench. After installation, the sprinkler wrench flats and frame arms must be in- spected and the wax coating re- touched (repaired) whenever the coat- ing has been damaged and bare metal is exposed. The wax coating on the wrench flats can be retouched by gen- tly applying a heated 1/8 inch diameter steel rod to the areas of wax that have been damaged, to smooth it back over areas when; bare rnbyal jg bxpose,c1 • . • • • • • • •• • NOTa ••. • • Only rrfot,,Nifrg of the Araxt oating 8p' • • plied Z ?MS wrench flats and frame • arms is permitted, and the retoudrldd ' is to be.partarmed 6nP,,efthe tirq@ QC. the in1 igl.spripkler inatg y4tion. • • T tie stestrod shoulc768 heated only to • • the p t •at dhich it cartbegin to melt • the w4x, ifncCapprop�g(•precautrQriu, need LO be taken, when handling Me heated roe' fin ordeP't8'prevene ih4 •: installel fromf' being Obr484 • • If attempts to retouch the wax coating with . complete coverage are unsuc- cessful, additional wax can be ordered in the form of a wax stick (the end of which is color coded). Only the correct color coded wax is to be used, and retouching of wrench flats and frame arms Is only permitted at the time of initial sprinkler installation. With the steel rod heated as previously de- scribed, touch the rod to the area re- quiring additional wax with the rod an- gled downward, and then touch the wax stick to the rod approximately one -half inch away from the area re- quiring retouching. The wax will melt and run down onto the sprinkler. The Series TY -B Recessed Pendent Sprinklers must be installed in ac- cordance with the following instruc- tions. Step A. After installing the Style 10 or 40 Mounting Plate, as applicable, over the sprinkler threads and with pipe thread sealant applied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting: using only the W -Type 7 Recessed Sprinkler Wrench (Ref. Figure 8). With reference to Figure 3 or 4, the W TYpe 7 Recessed Sprinkler Wrench is to be applied to the sprinkler wrench flats. Step C. After the ceiling has been in- TFP151 Page7of8 stalled or the finish coat has been ap- plied, slide on the Style 10 or 40 Clo- sure over the Series TY-B Sprinkler and push the Closure over the Mount- ing Plate until its flange comes in con- tact with the ceiling. Care and Maintenance The Series TY-B Sprinklers must be maintained and serviced in accord- ance with the following Instructions: NOTES Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, permission to shut down the affected fire protection system must be obtained from the proper authorities and all personnel who may be affected by this action must be notified. Absence of an escutcheon, which is used to cover a clearance hole, may delay the time to sprinkler operation in a fire situation. Sprinklers that are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated or otherwise altered after leaving the factory. Modi- fied sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers - before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be re- placed. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section). Frequent visual inspections are rec- ommended to be initially performed for corrosion resistant coated sprinklers, after the installation has been com- pleted, to verify the integrity of the cor- rosion resistant coating. Thereafter, annual inspections per NFPA 25 should suffice; however, instead of in- specting from the floor level, a random sampling of close -up visual inspec- tions should be made, so as to better determine the exact sprinkler condi- tion and the long term integrity of the corrosion resistant coating, as it may be affected by the corrosive conditions present. The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. The in- stalling contractor or sprinkler manu- facturer should be contacted relative to any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and /or national codes. Limited Warranty Products manufactured by Tyco Fire Products are warranted solely to the original Buyer for ten (10) years against defects in material and work- manship when paid for and properly installed and maintained under normal use and service. This warranty will ex- pire ten (10) years from date of ship- ment by Tyco Fire Products. No war- ranty is given for products or components manufactured by compa- nies not affiliated by ownership with Tyco Fire Products or for products and components which have bum 6ubject to misuse,impjdper instaflat!dn, corro sion, or which hate not Dee ir�stalled, maintainedtrnodified or rap1red in ac• cordance W, titbs'tpplicable Standards of the Nationg) Prote¢yon 44ssociaa tion, and/or Oil standards of any other Authorities Juri$dict/dn. Mate- rials found 611"/Co Fire reltrejs to be • defective shah •be either repaired or replaced, .et•T . Fire Products' sole •• option. Tyro F1 re;Productsmither as,; • sumes, ngr autorizes spy person to assume for ittaMy other obligation i3 connectionfn7ith t ?e salQ,df arnucts oY parts of products. Tyco Fite Products shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer's representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CON- TRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THE- ORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LABOR CHARGES, RE- GARDLESS OF WHETHER TYCO FIRE PRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENT SHALL TYCO FIRE PRODUCTS' LI- ABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. THE FOREGOING WARRANTY IS MADE IN LIEU OF ANY AND ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING WARRANTIES OF MERCHANTABILITY AND FIT- NESS FOR A PARTICULAR PUR- POSE, • • • ••• • • • • • • 530 2.8K UPRIGHT (1 /2 °NPT) TY1151 531 2.8K PENDENT (1 /2 °NPT) TY1251 570 5.6K UPRIGHT (1 /2 "NPT) TY3151 571 5.6K PENDENT (1 /2 "NPT) TY3251 590 8.0K UPRIGHT (3 /4 "NPT) TY4151 591 8.0K PENDENT (3 /4 "NPT) TY4251 560 8.0K UPRIGHT (1 /2 "NPT) TY4851 561 8.0K PENDENT (1 /2 "NPT) TY4951 Page 8 of 8 Ordering Procedure P/N 57 - XXX - X - XXX When placing an order, indicate the full product name. Refer to the Price List for complete listing of Part Numbers. Contact your local distributor for avail- ability. Sprinkler Assemblies with NPT Thread Connections: Specify: (Specify Model /SIN), Stand- ard Response, (specify K- factor), (specify temperature rating), Series TY-B (specify Pendent or Upright) Sprinkler with (specify type of finish or coating), P/N (specify from Table B). MODEUSIN 4 3 9 7 6 8 SPRINKLER NATURAL BRASS WHITE POLYESTER WHITE (RAL9010)* CHROME PLATED LEAD COATED WAX COATED 286°F/141°C MAX. WAX OVER LEAD 286°F/141°C MAX. TABLE B PART NUMBER SELECTION SERIES TY-B PENDENT AND UPRIGHT SPRINKLERS Recessed Escutcheon: Specify: Style (specify) Recessed Es- cutcheon with (specify finish), P/N (specify). 1/2" (15 mm) Style 10 Chrome Plated 1/2° (15 mm) Style 10 White Color Coated 1/2° (15 mm) Style 10 White RAL9010* 1/2° (15 mm) Style 10 Brass Plated 3/4° (20 mm) Style 40 Chrome Plated 3/4° (20 mm) Style 40 White Color Coated 3/4° (20 mm) Style 40 White RAL9010* 3/4° (20 mm) Style 40 Brass Plated P/N 56- 701 -9-010 P/N 56-701 -4 -010 P/N 56- 701 -3-010 P/N 56- 701 -2 -010 P/N 56 -700 -9-010 P/N 56- 700 -4 -010 P/N 56- 700 -3-010 P/N 56- 700 -2 -010 * Eastem Hemisphere sales only. Sprinkler Wrench: Specify: W -Type 6 Sprinkler Wrench, P/N 56- 000 -6 -387. Specify: W -Type 7 Sprinkler Wrench, P/N 56- 850 -4 -001. TYCO FIRE PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 135 155 175 200 286 360 TEMPERATURE RATING 135 °F /57 °C 155 °F /68 °C 175 °F /79 °C 200 °F /93 °C 286 °F /141 °C 360 °F /182°C • • • • • •• • • • • TFP151 •••• • ••• • • • •• • • Easteg g saless nly. • • • • • •••• • •• •••• • • • • • • •• •• • • • • • • • • • •••• • • • • •••• • Wax Sticks: • • (for retouching wren& Va:maged wax coating) Specify: (Specify color) color coded Wax Stick for retouching (specify tem- perature rating) temperature rated Se- ries TY-B Sprinklers, P/N (specify). •• • • • Black for 135 °F P/N 56 -065 -1 -135 Red for 155 °F P/N 56 -065 -1 -155 Yellow for 175 °F P/N 56- 065 -1 -175 Blue for 200 °F and 286 °F P/N 56 -065 -1 -286 NOTES Each wax stick is suitable for retouch- ing up to twenty-five sprinklers. The wax used for 286 °F sprinklers is the same as for 200°F sprinklers, and, therefore, the 286 °F sprinkler is limited to the same maximum ceiling tempera- ture as the 200 °F sprinkler (i.e., 150 °F). • • • • • • • • • tqco/ fire &Building Products Technical Services: Tel: (800) 381 -9312 / Fax: (800) 791 -5500 [ANTRAL Customer Service/Sales: Tel: (215) 362 -0700 / (800) 523 -6512 Fax: (215) 362 -5385 Series TY -B — Z8, 5.6, and 8.0 K- factor Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage General Description The Series TY-B, 2.8, 5.6, and 8.0 K- factor, Upright and Pendent Sprin- klers described in this data sheet are standard response - standard cover- age, decorative 5 mm glass bulb type spray sprinklers designed for use in light, ordinary, or extra hazard, com- mercial occupancies such as banks, hotels, shopping malls, factories, refin- eries, chemical plants, etc. The recessed version of the Series TY-B Pendent Sprinkler, where appli- cable, is intended for use in areas with a finished ceiling. it uses a two -piece Style 10 (1/2 inch NPT) or Style 40 (3/4 inch NPT) Recessed Escutcheon. The Recessed Escutcheon provides 1/2 inch (12,7 mm) of recessed adjust- ment or up to 3/4 inch (19,1 mm) of total adjustment from the flush pen- dent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Corrosion resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be ob- tained when exposed to corrosive at- mospheres. Although corrosion resis- tant coated sprinklers have passed the standard corrosion tests of the appli- cable approval agencies, the testing is IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems andcoin- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 8 not representative of all possible cor- rosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suitability of these coatings for any given corro- sive environment. The effects of ambi- ent temperature, concentration of chemicals, and gas /chemical velocity, should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. An intermediate level version of the Series TY-B Pendent Sprinkler can be obtained by utilizing the Series TY-B Pendent Sprinkler in combination with the Model S2 Shield. WARNINGS The Series TY-B Sprinklers described herein must be installed and main- tained In compliance with this docu- ment as well as with the applicable standards of the National Fire Protec- tion Association, in addition to the standards of any other authorities hav- ing jurisdiction. Failure to do so may impair the performance of these de- vices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Model /Sprinkler identification Numbers TYt151 - TY1251 - TY3151 - TY3251 - TY4151 - TY4251 - TY4851 - TY4951 - Upright . 2.8K,112"NPT Pendent 2.8K,1/2"NPT Upright 5.8K,1 /2 "NPT Pendent 5.6K,1/2 "NPT Upright 8.OK, 3/4 "NPT Pendent 8.0K, 3/4 "NPT Upright 8.OK, 1/2"NPT Pendent 8.0K,1/2 "NPT JULY, 2004 TFP151 Page 2 of 8 TFP151 ESCUTCHEON 7/16° (11,1 mm) PLATE SEATING ° •• NOMINAL SSU SURFACE NP T MAKE -IN DEFLECTOR 2 -1/4° (57,2 mm) 1 -9/16° (39,7 mm) WRENCH FLATS SSP DEFLECTOR PENDENT UPRIGHT 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector 2 - Button Assembly 5 - Compression 7 - Busting Screw CROSS SECTION * Temperature rating is indicated on deflector or adjacent to orifice seat on frame. • . • . ** Pipe thread connections per i.SO 7/•1 can be'3jc» jli on special request. • • • spe q •• • • ••• • • • FIGURE 1 •• • STANDARD RESPONSE SERIES TY-B UPRIGHT (TY1151) AND PENDENT (TY12$175PRINKLERS• 2.8 K -FACTOR, 1/2 INCH NPT • • • • •• • • • • •••• • • •. • •••• ESCUTCHEON 7/16° (11,1 mm) PLATE SEATING ** NOMINAL SURFACE N MAKE -IN 2 -3/16° (55,6 mm) 1 1 -1/2° (38,1 mm) STYLE 10 RECESSED ESCUTCHEON WRENCH FLATS SSP DEFLECTOR 2 -7/8° (73,0 mm) DIA. 1/2° NPT ** PENDENT RECESSED PENDENT UPRIGHT 1 - Frame 3 - Sealing 4 - Bulb 2 - Button Assembly 5 - Compression Screw 6 - Deflector SSU DEFLECTOR •• • • • • • 7/16° (11,1 mm) NOMINAL MAKE -IN 2 -3/16° (55,6 mm) • • • •• • • CROSS SECTION FIGURE 2 STANDARD RESPONSE SERIES TY-B UPRIGHT (TY3151) AND PENDENT (1Y3251) SPRINKLERS 5.6 K -FACTOR, 1/2 INCH NPT * Temperature rating is indicated on deflector or adjacent to orifice seat on frame. ** Pipe thread connections per ISO 7/1 can be provided on special request. • • • • • • • ••••• • • •0 • • TFP151 Page 3 of 8 ESCUTCHEON PLATE SEATING SURFACE 2 -5/16° (58,7 mm) 1 1 -9/16° (39,7 mm) 1/2° (12,7 mm) 3/4° ** NOMINAL NPT MAKE -IN STYLE 40 RECESSED ESCUTCHEON WRENCH FLATS SSU DEFLECTOR 2 -7/8° (73,0 mm) DIA. —.-1 3/4° NPT SSP DEFLECTOR PENDENT RECESSED PENDENT UPRIGHT 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector 2 - Button Assembly 5 - Compression 7 - Ejection Screw Spring 1/2° (12,7 mm) NOMINAL MAKE -IN t 2 -1/4° (57,2 mm) CROSS SECTION * Temperature rating is indicated on deflector quatcent to orifice seat on frame. • • • • ** Pipe thread connections pef'IW'7 /= can be ism on special request. • • • .• • FIGURE 3 • RSt STANDARD RESPONSE SERIES TY-B UPRIGHT (TY4151) AND PENDENT (TY425I j N RINK L. • 8.0 K- FACTOR, 3/4 INCH NPT • 410 0. • • • • • • • ESCUTCHEON 7/16" (11,1 mm) PLATE SEATING ° ** NOMINAL SSU SURFACE NPT MAKE -IN DEFLECTOR 2-1/4' (57,2 mm) 1 1 -9/16° (39,7 mm) 1 - Frame 3- Sealing 4 - Bulb 2 - Button Assembly 5 - Compression Screw WRENCH FLATS 2 -3/1 s° (55,6 mm) ' Olt —= 7 SSP DEFLECTOR PENDENT UPRIGHT 6 - Deflector CROSS SECTION •. .• • • • • • .. • • 4100. • 41 • • • •0• • • •• •• • * Temperature rating is indicated on deflector or adjacent to orifice seat on frame. ** Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 4 STANDARD RESPONSE SERIES TY-B UPRIGHT (TY4851) AND PENDENT (TY4951) SPRINKLERS 8.0 K- FACTOR, 112 INCH NPT • •• • •• • • • •41.. • • • • Page 4 of 8 TFP151 NOTES: 1. Listed by Underwriters Laboratories, Inc. (UL). 2. Listed by Underwriters Laboratories, Inc. for use in Canada (C -UL). 3. Approved by Factory Mutual Research Corporation (FM). 4. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 007k/03). 5. Approved by the City of New York under MEA 354 -01 -E. 6. VdS Approved (For details contact Tyco Fire & Building Products, Enschede, Netherlands, Tel. 31- 53- 428- 4444/Fax 31- 53- 428 - 3377). 7. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/05). 8. Where Polyester Coated, Lead Coated, Wax Coated, and Wax over Lead Coated Sprinklers are noted to be UL and C -UL Listed, the sprinklers are UL and C-UL Listed as Corrosion Resistant Sprinklers. Where Lead Coated, Wax Coated, and Wax over Lead Coated Sprinklers are noted to be FM Approved, the sprinlers are FM Approved as Corrosion Resistant Sprinklers. * Installed with Style 10 (1/2° NPT) or Style 40(3/4° NPT) 3/4° Total Adjustment Recessed Escutcheon, as applicable. '* 150 °F /66 °C Maximum Ceiling Temperature. ""* Frame and deflector only. Listings and approvals apply to color (Special Order). N/A: Not Available TABLE A LABORATORY LISTINGS AND APPROVALS •••• • • •• •• • •••• • ••• • • ••• •••• •• • •••• • • • SPRINKLER•FINISH (See Note 8) K TYPE TEMP. BULB UOUID NATURAL BRASS CHROME • PLATED WHITE"" POLYESTER LEAD I COATED WAX COATED I WAX OVER LEAD COATED 135 °F /57 °C Orange PENDENT 155 °F /68 °C Red 2.8 (TY1251) 1, 2, 3 N/A 175'F179°C Yellow 1/2" and NPT UPRIGHT 200 Green (iY1151) 286°F/141 °C Blue 360°F/182 °C Mauve 1, 2 135 °F /57°C Orange PENDENT (TY3251) 155 °F /68 °C Red 1,2,3,4,5,6,7 1,2,3,5 1,2,3,5 1,2,3,5 175 °F179 °C Yellow and UPRIGHT 200 °F /93 °C Green 5.6 (TY3151) 286 °F /141 °C Blue 1 * *,2 * *, 3**, 5 ** 1", 2 ", 3* *, 5** 1/2" T 360°F /182 °C Mauve • _ wa • 135 °F /57 °C Orange • • • • • • • • • • RECESSED 155 °F /68 °C Red • • • ` • • PENDENT 1,2,3,4,5 1,2,4,5 •••N4' • • 175 °F /79 °C (TY3251 • Yellow • • • • • • • • • Figure 4 200 °F /93 °C Green • ... • • • • .. • _. • 135'F/57°C Orange • • •••• • • • • • PENDENT (TY4251) 155°F/68°C Red 1,2,5 •• •• •$,08.5 •• • •• .1, 2,5 175 °F /79 °C Yellow and 1,2,3,4,5,6,7 • • • •••. • . • 8.0 UPRIGHT 200 °F /93 °C Green • •. • • • • • • NPT (TY4151) 286 °F /141 °C Blue 1 "", 3v, 5" 2' • •1'$,Q2i*, 5'" •" 360°F/182°C Mauve N/A • • • 135 °F /57°C Orange RECESSED 155 °F /68 °C Red PENDENT 1, 2, 3, 4, 5 WA 175 °F /79 °C Yellow (Y4251)• Figure 5 200 °F /93 °C Green 135°F/57°C Orange PENDENT 155 °F /68 °C Red 8.0 (TY4951) 175 °F /79 °C Yellow 1/2' and 1,2,3,5 N/A NPT UPRIGHT (TY1) 200 °F /93 °C Green 286°F/141 °C Blue 360 °F /182 °C Mauve Page 4 of 8 TFP151 NOTES: 1. Listed by Underwriters Laboratories, Inc. (UL). 2. Listed by Underwriters Laboratories, Inc. for use in Canada (C -UL). 3. Approved by Factory Mutual Research Corporation (FM). 4. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 007k/03). 5. Approved by the City of New York under MEA 354 -01 -E. 6. VdS Approved (For details contact Tyco Fire & Building Products, Enschede, Netherlands, Tel. 31- 53- 428- 4444/Fax 31- 53- 428 - 3377). 7. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/05). 8. Where Polyester Coated, Lead Coated, Wax Coated, and Wax over Lead Coated Sprinklers are noted to be UL and C -UL Listed, the sprinklers are UL and C-UL Listed as Corrosion Resistant Sprinklers. Where Lead Coated, Wax Coated, and Wax over Lead Coated Sprinklers are noted to be FM Approved, the sprinlers are FM Approved as Corrosion Resistant Sprinklers. * Installed with Style 10 (1/2° NPT) or Style 40(3/4° NPT) 3/4° Total Adjustment Recessed Escutcheon, as applicable. '* 150 °F /66 °C Maximum Ceiling Temperature. ""* Frame and deflector only. Listings and approvals apply to color (Special Order). N/A: Not Available TABLE A LABORATORY LISTINGS AND APPROVALS •••• • • •• •• • •••• • ••• • • ••• •••• •• • •••• • • • TFP151 5/811/4° (15,91-6,4 mm) FACE OF SPRINKLER FITTING MOUNTING SURFACE CLOSURE 2-7/8' DIA. (73,0 mm) 2-1/4' DIA. (57,2 mm) SERIES TY-B 3/4° (19,1 mm) 1/4° (6,4 mm) MOUNTING PLATE 1 -1/4° (31,8 mm) 3/4° (19,1 mm) FIGURE 5 SERIES TY-B RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO -PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 5.6 K- FACTOR, 1/2 INCH NPT 1 5/8 ±1/4° (15,9±6,4 mm) FACE OF SPRINKLER FITTING MOUNTING SURFACE CLOSURE SERIES TY-B 2 -7/8° DIA. (73,0 mm) 2 -1/4° DIA. (57,2 mm) 3/4° (19,1 mm) 1/4° (6,4 mm) MOUNTING PLATE 1/8° (3,2 mm) t 1 -5/16° (33,3 mm) 13/16° (20,6 mm) FIGURE 6 SERIES TY-B RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON 8.0 K- FACTOR, 3/4 INCH NPT Page 5 of 8 WRENCH RECESS (END °B° USED FOR 8/4° NPT MODELS) WRENCH RECESS (END °A° USED FOR 1/2° NPT MODELS) FIGURE 7 W -TYPE 6 SPRINKLER WRENCH WRENCH RECESS ••. • ••• • • • • •• • • • • • •••• ^'' • •• 'ANN WRENCH. ..% .• ENGAGEMENT WI to SPRINKLER' 'WRENCHING AREA • • • • •••• • •• . FIiURE B. ••• W-TYPE 7 REC{ SEP SPRINKLER WRENCH • • • • • • • • • • • •••• • • •• •� • Page 6 of 8 Technical Data Approvals UL and C -UL Listed. FM, LPCB, VdS, and NYC Approved. (Refer to Table A for complete approval information including corrosion resis- tant status.) Maximum Working Pressure 175 psi (12,1 bar) Discharge Coefficient K = 2.8 GPM/ps1 (40,3 LPM/bar K = 5.6 GPM /psi / (80,6 LPM/bar K = 8.0 GPM/psi (115,2 LPM/bar Temperature Ratings Refer to Table A Finishes Sprinkler: Reessed Escutcheon: White Coated, Chrome Plated, or Brass Plated Physical Characteristics Frame Bronze Button Brass /Copper Sealing Assembly Beryllium Nickel w/Teflont Bulb Glass Compression Screw Bronze Deflector Copper Bushing (K =2.8) Bronze Operation The glass Bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass Bulb, allowing the sprinkler to activate and water to flow. Design Criteria The Series TY B Pendent and Upright Sprinklers are Intended for fire protec- tion systems designed in accordance with the standard installation rules rec- ognized by the applicable Listing or Approval agency (e.g., UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM's Loss Prevention Data Sheets). Only the Style 10 or 40 Recessed Escutcheon, as applicable, is to be used for recessed pendent installations. Installation The Series TY B Sprinklers must be installed in accordance with the follow- ing Instructions: NOTES Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be.present. The diameterof the air bubble is approximately 1/16 inch (1,6 mm) for the 135 °F /57°C to 3/32 inch (2,4 mm) for the 360 °F /182 °C temperature ratings. A leak tight 1/2 inch NPT sprinkler joint should be obtained with a torque of 7 to 14 ft.lbs. (9,5 to 19,0 Nm). A maxi- mum of 21 ft. lbs. (28,5 Nm) of torque may be used to Install sprinklers with 1/2 NPT connections. A leak tight 3/4 inch NPT sprinkler joint should be ob- tained with a torque of 10 to 20 ft.lbs. (13,4 to 26,8 Nm). A maximum of 30 ft.lbs. (40,7Nm) of torque is to be used to Install sprinklers with 3/4 NPT con- nections. Higher levels of torque may distort the sprinkler inlet and cause leakage or impairment of the sprinkler. Do not attempt to make -up for insuffi- cient adjustment in the escutcheon plate by under- or over - tightening the sprinkler. Readjust the position of the sprinkler fitting to suit The Series TY -B Pendent and Up- right Sprinklers must be installed in accordance with the following instruc- tions. Step 1. Pendent sprinklers are to be installed in the pendent position, and upright sprinklers are to be installed in the upright position. Step 2. With pipe thread sealant ap- plied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W -Type 6 Sprinkler Wrench (Ref. Figure 7), except that an 8 or 10 inch adjustable Crescent wrench is to be used for wax coated sprinklers. With reference to Figures 1, 2, 3, and 4 the W -Type 7 Sprinkler Wrench or the adjustable Crescent wrench, as applicable Is to be applied to the wrench flats. When installing wax . coated sprinklers with the adjustable Crescent wrench, additional care needs to be exercised to prevent damage to the Wax coating on the sprinkler wrench flats or frame arms and, consequently, exposure of bare metal to the corrosive environ- ment. The jaws of the wrench should be opened sufficiently wide to pass over the wrench flats without damag- TFP1 51 ing the wax coating. Before wrench tightening the sprinkler, the jaws of the wrench are to be adjusted to just con- tact the sprinkler wrench flats. After wrench tightening the sprinkler, loosen the wrench jaws before removing the wrench. After installation, the sprinkler wrench flats and frame arms must be in- spected and the wax coating re- touched (repaired) whenever the coat- ing has been damaged and bare metal is exposed. The wax coating on the wrench flats can be retouched by gen- tly applying a heated 1/8 inch diameter steel rod to the areas of wax that have been damaged, to smooth It back over areas where bare metal is exposed. NOTES Only retouching of the wax coating ap- plied to the wrench t14 FYI fram arms is riergftt4d, and Cie „ etouching • • is to be 12e/formed only atdhe time of • the inmarsprtn Ter instafletiorf. • The steel rpd, ould bq Lieated only;o • • • the pointat which it can begin to milt • the wax, grid 3pproprI to 1Pecautiorie ; • • • need to b1f tM4n, whin trilling th ®• • • heated rod, •in order te•prewent t ae installer kerrnbteing burned • if attem to retouch � coating • • • • with corjrplele coverage ere unsuc- . cessful, aeldi oma/ wax sandal ordergd • • • in the form of a wax s'ip '(tlte end of which is color coded). Only the correct color coded wax Ls to be used, and retouching of wrench flats and frame arms is only permitted at the time of initial sprinkler installation. With the steel rod heated as previously de- scribed, touch the rod to the area re- quiring additional wax with the rod an- gled downward, and then touch the wax stick to the rod approximately one -half Inch away from the area re- quiring retouching. The wax will melt and run down onto the sprinkler. The Series TY -B Recessed Pendent Sprinklers must be installed in ac- cordance with the following instruc- tions. Step A. After installing the Style 10 or 40 Mounting Plate, as applicable, over the sprinkler threads and with pipe thread sealant applied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W -Type 7 Recessed Sprinkler Wrench (Ref. Figure 8). With reference to Figure 3 or 4, the W -Type 7 Recessed Sprinkler Wrench is to be applied to the sprinkler wrench flats. Step C. After the ceiling has been in- TFP151 stalled or the finish coat has been ap- plied, slide on the Style 10 or 40 Clo- sure over the Series TY B Sprinkler and push the Closure over the Mount- ing Plate until its flange comes in con- tact with the ceiling. Care and Maintenance The Series TY B Sprinklers must be maintained and serviced in accord- ance with the following instructions: NOTES Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, permission to shut down the affected fire protection system must be obtained from the proper authorities and all personnel who maybe affected by this action must be notified. Absence of an escutcheon, which is used to cover a clearance hole, may delay the time to sprinkler operation in a fire situation. Sprinklers that are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated or otherwise altered after leaving the factory. Modi- fied sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced If they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers - before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be re- placed. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section). Frequent visual inspections are rec- ommended to be initially performed for corrosion resistant coated sprinklers, after the installation has been com- pleted, to verify the integrity of the cor- rosion resistant coating. Thereafter, annual inspections per NFPA 25 should suffice; however, instead of in- specting from the floor level, a random sampling of close -up visual.inspec- tions should be made, so as to better determine the exact sprinkler condi- tion and the long term integrity of the corrosion resistant coating, as it may be affected by the corrosive conditions present. The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. The in- stalling contractor or sprinkler manu- facturer should be contacted relative to any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national codes. Limited Warranty Page 7of8 Products manufactured by Tyco Fire Products are warranted solely to the original Buyer for ten (10) years against defects in material and work- manship I when paid for and properly installed and maintained under normal use and Service. This warranty will ex- pire ten c10) years from date of ship- ment by Tyco Fire Products. No war- ranty is given for products or components manufactured by compa- nies not affiliated by ownership with Tyco Fire Products or for products and components which have been subject to misuse, Improper installation, corro- sion, or which have not been Installed, maintained, modified oareli tied in ac- cordance witiskpplicabla'Sfandards OP • •; • the Nationb? Fire PrototiAssocia- • don, and , etandardew other...:. Authorities.ldvimg Jurisdiction. Matg- • vials foundJiy. Vco Fire to be• • • • • defective•gligll be either•rspeired $r • replaced, of Tyco Fire Products' sole'; • •. option. Tf& Fif@ Prodyetb:llither as• • • • sumes, Mir ENthorizes any person b • • . • assume porst •any other obligation in • connection withahe salea products pL •, ! • parts of produpts. Tyco f re • Producls shall not•gg tegponsible for sprinkles design errors eintaurate br • incomplete Informatioi upplied by Buyer or Buyer's representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CON- TRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THE- ORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LABOR CHARGES, RE- GARDLESS OF WHETHER TYCO FIRE PRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENT SHALL TYCO FIRE PRODUCTS' LI- ABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. THE FOREGOING WARRANTY IS MADE IN LIEU OF ANY AND ALL OTHER WARRANTIES EXPRESS OR JMPLI D. INCLUDING WARRANTIES OF MERCHANTABILITY AND FIT - NFS4 F(R A PARTI(I!l AR PUR- POSE 530 2.8K UPRIGHT (1 /21NPT) TY1151 531 2.8K PENDENT (1 /2 1NPT) TY1251 570 5.6K UPRIGHT (1/2NPT) TY3151 571 5.6K PENDENT (1/2°NPT) TY3251 590 8.0K UPRIGHT (3/4 °NPT) TY4151 591 8.0K PENDENT (3 /4 °NPT) TY4251 560 8.0K UPRIGHT (1/2NPT) TY4851 561 8.0K PENDENT (1/21•PT) TY4951 Page 8 of 8 Ordering Procedure P/N 57 XXX- X -tXXX When placing an order, indicate the full product name. Refer to the Price List for complete listing of Part Numbers. Contact your local distributor for avail- ability. Sprinkler Assemblies with NPT Thread Connections: Specify: (Specify Model/SIN), Stand- ard Response, (specify K- factor), (specify temperature rating), Series TV-B (specify Pendent or Upright) Sprinkler with (specify type of finish or coating), P/N (specify from Table B). . MODEIJSIN 1 4 3 9 7 6 8 SPRINKLER NATURAL BRASS WHITE POLYESTER WHITE (RAL9O10)' CHROME PLATED LEAD COATED WAX COATED 286°F/141 °C MAX. WAX OVER LEAD 286°F /141 °C MAX. TABLE B PART NUMBER SELECTION SERIES TY-B PENDENT AND UPRIGHT SPRINKLERS Recessed Escutcheon: Specify: Style (specify) Recessed Es- cutcheon with (specify finish), P/N (specify). 1/2° (15 mm) Style 10 Chrome Plated 1/2' (15 mm) Style 10 white Color Coated 1/2° (15 mm) Style 10 White RAL9010' 1/2° (15 mm) Style 10 Brass Plated 3/4" (20 mm) Style 40 Chrome Plated 3/4° (20 mm) Style 40 White Color Coated 3/4° (20 mm) Style 40 Whte RAL9010' 3/4° (20 mm) Style 40 Brass Plated P/N 56-701-9-010 P/N 56 -701-4-010 P/N 56- 701 -3-010 P/N 56- 701 -2 -010 P/N 56-700-9-010 P/N 56-700-4-010 P/N 56- 700 -3-010 P/N 56- 700 -2 -010 • Eastem Hemisphere sales only. Sprinkler Wrench: Specify: W -Type 6 Sprinkler Wrench, P/N 56- 000 - 6-387. Specify: W -Type 7 Sprinkler Wrench, P/N 56 -850 -4 -001. 135 155 175 200 286 360 TEMPERATURE RATING 135 °F /57 °C 155 °F /68 °C 175 °F /79 °C 200 °F /93°C 286 °F /141 °C 360 °F /182 °C • • • • •••• • • • • Eastatti HeTispherrbal4s Qnly. • •••• • • •• TYCO FIRE PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 •• • •• • • • • • •• •••• • • • •• •• •• • TFP1S1 • • • Wax Sti4tt: •: (for retouching wrench. damaged • • • • wax coating • • •••• • • Specify: ( Specfy coin lol r code • Wax Stick for retouching 4specify tem- perature rating) temperature rated Se- ries TY B Sprinklers, P/N (specify). • • • Black for 135 °F P/N 56-065-1-135 Red for 155 °F P/N 56 -065.1 -155 Yellow for 175 °F P/N 56 -065-1 -175 Blue for 200 °F and 286°F P/N 56 -065 -1 -286 NOTES Each wax stick is suitable for retouch- ing up to twenty -five sprinklers. The wax used for 286 °F sprinklers is the same as for 200°F sprinklers, and, therefore, the 286°F sprinkler is limited to the same maximum ceiling tempera- ture as the 200 °F sprinkler (i.e., 150 °F). •• • • • • • • tqcci I & Building Products Technical Services: Tel: (800) 381 -9312 / Fax: (800) 791 -5500 CENTRAL Customer Service/Sales: Tel: (215) 362 -0700 / (800) 523 -6512 Fax: (215) 362 -5385 Series EC -11 & EC-14 — 11.2 and 14.0 K- factor Extended Coverage (Light and Ordinary Hazard) Upright, Pendent, and Rec. Pendent Sprinklers General Description The Series EC -11 and EC -14 Ex- tended Coverage Upright and Pendent Sprinklers are decorative glass bulb sprinklers designed for use in light or ordinary hazard occupancies. They are intended for use in automatic sprinkler systems designed in accord- ance with standard installation rules (e.g., NFPA 13) for a maximum cover- age area of 400 ft (37,2 m as com- pared to the maximum coverage area of 130 ft (12,1 m for standard cover- age sprinklers used in ordinary haz- ard occupancies or 225 ft (20,6 m for standard coverage sprinklers used in light hazard occupancies. The Series EC -11 and EC -14 Sprin- klers feature a UL and C -UL Listing that permits their use with unob- structed or non - combustible ob- structed ceiling construction as de- fined and permitted by NFPA 13, as well as a specific application listing for use under concrete tees. The Series EC -11 and EC -14 Ex- tended Coverage Sprinklers have been fire tested to compare their per- formance to that of standard coverage spray sprinklers. These tests have shown that the protection provided is equal to or more effective than stand- ard coverage spray sprinklers. IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 8 Corrosion resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be ob- tained when exposed to corrosive at- mospheres. Although corrosion resis- tant coated sprinklers have passed the standard corrosion tests of the appli- cable approval agencies, the testing is not representative of all possible cor- rosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suitability of these corrosion resistant coatings for any given corrosive environment. The effects of ambient temperature, concentration of chemicals, and gas /chemical velocity, should be con- sidered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. WARNINGS The Series EC -11 and EC -14 Ex- tended Coverage Sprinklers described herein must be installed and main- tained in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association, in addition to the standards of any other authorities hav- ing jurisdiction. Failure to do so may impair the integrity of these devices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted relative to any questions. • • • • •... Model /Sprinkler Identification Number TY5137 - Upright, 11.2K TY5237 - Pendent, 112K TY6137 - Upright, 14.0K TY6237 - Pendent,14.0K TY5137 is a redesignation for C5137, G1894, and S2510. TY5237 is a redesignation for C5237, G1893, and S2511. TY6137 is a redesignation for C6137, G1896, and S2610. TY6237 is a redesignation for C6237, G1895, and S2611. APRIL, 2004 TFP22O HAZARD TYPE TEMP. UO D BRASS ASS NATURAL PLATED •• PO`'YEST + F •• • pikTED s • • • 135 °F /57 °C Orange • UGHT UPRIGHT K =11.2 (TY5137) 155 °F /68 °C Red 2 ' l'Y'� •••• • • • • 175F/79°C Yellow • • • I PENDENT K =11.2 (TY5237) 1, 2, 4 • • • • 1, 4 , °C Refer to Table B for K =14.0 (TY6237) 200 °F /93 Green • • • 286 °F /141 °C Blue UL and C -UL Sensitivity Rating 135 °F /57 °C Orange and REC. PENDENT 1, 2, 3, 4 °F °C Refer to Table C for K =11.2 (TY5237) 155 /68 Red N/A 175'F/79°C Yellow FM K =14.0 (TY6237) Sensitivity Rating With Style 30 1, 2, 4 Escutcheon 200°F/93°C Green 286 °F /141 °C Blue UPRIGHT 135*F/57°C Orange K =11.2 (TY5137) 1, 2, 3, 4 155 F/68 C Red ORDINARY K =14.0 (TY6137) 1, 2, 3, 4 175 °F /79 °C Yellow and Refer to Table B for PENDENT 2O0FI93°C Green 1 2 4 UL and C-UL K =11.2 (TY5237) 286 °F /141 °C Blue Sensitivity Rating K =14.0 (TY6237) and REC. PENDENT 135 °F /57 °C Orange Refer to Table C for FM K=11.2 (TY5237) K =14.0 (TY6237) 155 °F /68°C Red 1, 2, 4 N/A 175 °F /79 °C Yellow Sensitivity Rating With Style 40 Escutcheon 200 °F /93 °C Green Page 2 of 8 1 - Frame 2 - Button 3 - Sealing Assembly 4 - Bulb 5 - Compression Screw 6 - Deflector' ° Temperature rating is indicated on deflector " Pipe thread connections per ISO 7/1 can be provided on special request. WRENCH FLAT 1/2" (12,7 mm) J NOMINAL MAKE -IN UPRIGHT 3/4" ** NPT 2- 7/16" (61,9 mm) UPRIGHT & PENDENT FIGURE 1 SERIES EC -11 AND EC -14 EXTENDED COVERAGE SPRINKLE* • • • 11.2 K FACTOR (TY5137) UPRIGHT AND (TY5237) PENDENT • • • 14.0 K- FACTOR (TY6137) UPRIGHT AND (TY6237) PENDENT PENDENT ESCUTCHEON PLATE SEATING SURFACE • CROSS SECTION TFP22O •••• • • •••• • • ••• • • • • • •• • • SPRINKLERONISFl pee Nrtte I) • • NOTES: 1.Usted by Underwriters Laboratories, Inc. (UL). 2.Listed by Underwriters Laboratories, Inc. for use in Canada (C -UL). 3. Approved by Factory Mutual Research Corporation (FM). 4. Approved by the City of New York under MEA 177 -03 -E. 5. Where Polyester Coated or Lead Coated Sprinklers are noted to be UL and C -UL Listed, the sprinklers are UL and C -UL Listed as Corrosion Resistant Sprinklers. 'Frame and Deflector only. Listings and approvals apply to color (Special Order). " Pendent Only. N/A: Not Available TABLE A, LABORATORY LISTINGS AND APPROVALS • • • • • • • • • TFP22O Page 3 of 8 AREA STYLE 14x14 Up. or Pend. 14 x 14 Style 30 Recessed 14 x 14 Style 40 Recessed 16 x 16 Up. or Pend. 16 x 16 Style 30 Recessed 16 x 16 Style 40 Recessed QR: Quick Response SR: Standard Response N/A: Not Applicable Does not apply to Upright K =14.0 UGHT HAZARD ORDINARY HAZARD 135 °F 155 °F 175 °F 200 °F 286 °F 135 °F 155 °F 175 °F 200 °F 286 °F - - - - - N SR SR SR SR SR SR SR SR SR N/A SR SR SR SR N/A QR* QR* QR* QR* QR* + SR SR SR SR SR QR' OR* QR* QR' QR* SR SR SR SR N/A N/A N/A N/A N/A N/A SR SR SR SR NIA 18 x 18 Up. or Pend. QR* OR* QR* QR* QR* SR SR SR SR SR 18 x 18 Style 30 Recessed QR* QR* QR* QR* QR* SR SR SR SR N/A 18 x 18 Style 40 Recessed N/A N/A N/A N/A N/A SR SR SR SR N/A 20 x 20 Up. or Pend. QR* QR* QR* SR* SR* SR SR • SR • S • SR •.SR 20 x 20 Style 30 Recessed QR* SR* OR* SR* SR* SR SR • •st� • • SR . "NA 20 x 20 Style 40 Recessed N/A N/A N/A N/A N/A SR SR • • $6 • • SR • • • • i1A 4 • • 4 4 • • • • • •••• • •• . ...• . TABLE B • • • • • • • 4 SENSITIVITY RATING FOR UL. AND C -UL LISTING OF SERIES EC -11 OR EC- 1.1.$9RSNKLERS • (SEE TABLE D FOR PERMITTED K- FACTOR/AREA COMBINATIONS) : •••• • •••• • AREA STYLE 14 x 14 Up. or Pend. 14 x 14 Style 30 Recessed 14 x 14 Style 40 Recessed 16 x 16 Up. or Pend. 16 x 16 Style 30 Recessed 16 x 16 Style 40 Recessed QR: Quick Response SR: Standard Response N/A: Not Applicable * Pendent Only •• • • ••• • UGHT HAZARD ORDINARY HAZARD' • •' 135 °F 155 °F 175 °F 200 °F 286 °F 135 °F 155 °F 175 °F 200 °F 286 °F — - - - - t/ SR SR SR — NI/ A N/A N/A N/A N/A — N/A N/A N/A N/A NIA QR* QR* N/A N/A N/A SR SR SR SR SR QR QR N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 18 x 18 Up. or Pend. QR* QR* N/A N/A N/A SR SR SR SR SR 18 x 18 Style 30 Recessed QR QR N/A N/A N/A N/A N/A N/A N/A N/A 18 x 18 Style 40 Recessed N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 20 x 20 Up, or Pend. QR* QR* N/A N/A N/A SR SR SR SR SR 20 x 20 Style 30 Recessed QR QR N/A N/A N/A N/A N/A N/A N/A N/A 20 x 20 Style 40 Recessed N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A TABLE C SENSITIVITY RATING FOR FM APPROVAL OF SERIES EC -11 OR EC -14 SPRINKLERS (SEE FM LOSS PREVENTION DATA SHEET 2 -8N FOR PERMITTED K- FACTOR/AREA COMBINATIONS) • • •• • .• • • • ••• • • •••• • • • Page 4 of 8 Technical Data Approvals UL and C - Listed. FM. Approved. (Refer to Table A. for complete approval information including corrosion resis- tant status. The approvals apply to the service conditions indicated in the De- sign Criteria- section.) Maximum Working Pressure 175 psi (12,1 bar) Pipe Thread Connection 3/4 Inch NPT Discharge Coefficients K = 11.2 GPM/psili2 (161,3 LPM/bar K =14.0 GPM/psit /2 (201,6 LPM/barlI Temperature Ratings 135 ° F /57°C to 286 Finish Sprinkler: Refer to Table A Recessed Escutcheon: White Coated, Chrome Plated, and Brass Plated Physical Characteristics Frame Bronze Button Bronze Sealing Assembly Beryllium Nickel w/Teflon Bulb Glass (3 mm dia.) Compression Screw Deflector Bronze Brass Patents U.S.A. Patent Numbers 5,366,022; 5,579,846; 5,584,344; 5,609,211; 5,862,994; and 5,865,256 are appli- cable to the Series EC -11 and EC14 Sprinklers. Other patents are pending with regard to other design features. Operation The glass bulb contains a :fluid• which expands when exposed to heat When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, which then allows the sprin- kler to activate and flow water. Design Criteria The Series EC -11 and EC -14 Ex- tended Coverage Sprinklers must only be installed in accordance with the ap- pitat \e \A- Zat ¶U� VAttg oc F M Approval requirements as indicated below. Only the Style 30 or 40 Re- cessed Escutcheon is to be used for recessed installation, as applicable (Ref: Table A; B,' and C).. UL arid: C-UL Listing Requirements 1; The Series fC�11 anal EC-14 Spein- .ktersy be used for the coverage areas shown In Table D, based on maintaining the minimum:specified ftgw rate as -a function -of coverage area Tand bazar f 9roup:for aw.ot the. sprinklers. in the design;area. 2. With respect t4 heat se ,sJtiriity, .the Series EC-11 and EC 14Sprinklers are permitted toilet:m.0d with unob- structed or .non - combustible ob- structed ceiling construction as de- fined and permitted by NFPA 13. For example: Unobstructed, combustible or non- combustible, ceiling construction with as deflector to ceiling/roof deck distance of 1 to 12 inches (28 to 300 mm). Obstructed, noncombustible, ceiling construction with a deflector location below structural members of 1 to 6 inches (25 to 150 mm) and a:maxi murk' deflector to ceilingtroof deck distance of 22 inches (550 mm). 3. The minimum allowable'spacing be- tween the Series FC:-11 and EC-14 Sprinklers, to prevent cold solder- ing, is 8 feet (2,4 m) forupright sprin- klers and 9 feet (2,7 m) for pendent sprinklers. 4. The Series EC -11 and EC-14 Sprin- klers are to be installed in accord - ance with all other requirements of NFPA 13 for extended coverage W- right and pendent sprinklers. UL and C-UL Specific Application Listing Regirireit ants For installation: Under Concrete Tees The Series; ECM and EC44 Ex- tended Coverage Upright Sprinklers (TN5137 & TY6137) have , a tit, and C-i1L Specifo Application Listing for use, under concrete tees when in- stalled as follows: 1. The sterns of the concrete tee con - svu Lion must spaced at less than c et.(2,3: m); on. comer but more. than 3' feet (M9 m) on center. The depth of the Ooncrete teesmurst not exceed '30 inches: (762 m)..The maxiinuin, permitted : concr m ete tee • enger .3 •.1ea,'t:(9,8 err); fip■ever, Where :the :concrete tee. :length ex- tiaids32%eei0,8 m), tocticotobus tible baffles, equal in height to the depth of the tees, can be installed so that the space between the tees TFP22O does not exceed 32 feet (9,8 m) in length. 2. The sprinkler. deflectors are to be located in a horizontal plane at or above 1 inch (26,4 mm) below the bottom of the concrete tee stems. 3. When the sprinkler deflectors are located , higher than a horizontal plane 1 inch (251,4 mm) beneath the bottorn of the concrete tee stems, the. ..Obstruction t0 sprinkler dis- .Charge criteria requirements of NFPA 13 for extended coverage up- right sprinklers applies. FM :Approval Requirements ... The .Series . ECG11 • c: AC -14 FiS:.. • .tende•ouezage Sprinklers are to be • installed%) aceordans8 viZth;the apppli - . :cable:FFatttztCAuttiaa Criss Preven8611'' Data Skset#erlimited use in buildiljgg. •; of specific ref constrestior ► and forthe • protectibp afArtain ititt ordinary.. hazard iggq-kiptage . non -fly ..• mable or:oorrrhustibleolrqq ).occup8n- ... cies. ki?drrrtation provided h the FM' • Loss Prpe .Data Sh ets relate to, • . but are i o t l to, h y d r vUO d e s ? . ' . ceWng rtlgpe. and • obslz�tions, mini mum afl�.maZimum alloy le sp$L - • • ing, and deflector -to eej(jng distance. instaflation The Series EC -11 and EC-14 Sprin- klers must be. installed in accordance with the following instructions: NOTES Do not install any bulb type sprinkler if the bulbar creaked ofthere is a loss of liquid from the bulb. With the sprinkler held horizontally a small air bubble shouldhepresent The diameterof the air bubble is approximately. 1/16 inch (1,6. mnei) for the:135. °F/57 °C to 3/32 inch (2,4 tam 1 for the 286°F/141°C temperature ratings. A leak tight 3/4inch NPT sprinklerjoint should be tobtairied, with a torque of 10 m 20 fl. bs. (13,4 to 26,8 Nm). A maxi - mum' of 30 ft lbs.:(40.7 Nm) of torque is to be used to -Install sprinklers. Higher levels of tOrgfie may distort the sprinkler". inlet with. consequent leak- age or impairment of the sprinkler. Do not attempt to compensate for in- sufl3cient adjustrnent in an Escutcheon Plate by under- or over- tightening the Sprinkler: Readjust. the position of the sprinklerftting.to suit. Step A t .The sprinldec must be Installed with the deflector parallel to the mount- ing surface. Pendent sprinklers must be installed in the pendent position, TFP22Q _ 1/2±1/8" (12,7±3,2 mm) FACE OF SPRINKLER FITTING f \ MOUNTING SURFACE CLOSURE 2-7/8" DIA. (73,0 mm) 2-1/4° DIA. (57,2 mm) 1/2° (12,7 min) 1/4° (6,4 mrn) MOUNTING PLATE 1/8° (3,2 mm) 1-3/8" (34,9 mm) 1- 1/8°'(28,6 mm) ROME SERIES EC-11 AND €f. --14 Rgogsagg PENDENT SPRINKLER ASSEMBLY WITH TWO -PIECE 1/21NCH-TOTAL ADJUSTMENT STYLE 30 RECESSED ESCUTCHEON 5/8±1/4" (15,9±6,4 mm) FACE OF SPRINKLER FITTING I _ 2-7/8° DIA. (73,0 mm) 2 -1/4° DIA. (57,2 mm) f MOUNTING SURFACE CLOSURE MOUNTING PLATE 3/4° (19,1 mm) 1/4" (6,4 mm) 1/8° ( mm) 1 -3/8° (34,9 mm) 7/8° (22,2 mm) FIGURE 3 SERIES EC-11 AND EC-I4 RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE .314:INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON Pogo 5eiS °FITTING SIDE° TOWARDS SPRINKLER FITTING F/GURE.4 . W -TYPE &SPRINKLER WRENCH WRENCH RECESS (END °A") and upright sprinklers must be in- stalled in the upright position. Step 2. After installing the Style 30 or 40 mounting plate (or other escutch- eon, as applicable) over the sprinkler pipe threads and with pipe thread sealant applied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 3. Wrench tighten upright or pen- dent sprinklers using only the W -Type 3 (End A) Sprinkler Wrench. Wrench tighten the recessed pendent sprin- klers using only the W -Type 22 Sprin- kler Wrench. The wrench recess of the applicable sprinkler wrench (Ref. Fig- ure 4 and 5) is to be applied to the sprinkler wrench flats (Ref. Figure 1). • • •• • •• • • • • •• • • •• • • Page 6 of 8 DESCRIPTION AREA TY5137 (K=11.2) UPRIGHT TY5237 (K=11.2) PENDENT TY6137 (K=14.0) UPRIGHT TY6237 (K =14.0) PENDENT 1 ft. = 0.3048 m 1 ft = 0.093 m 1 gpm = 3.785 Ipm 1 psi = 0.06895 bar 1 gp = 40.74 mm/min 14x 14 16 x 16 18 x 18 20x20 14x 14 16x16 18x 18 20 x 20 14 x 14 16x16 18 x 18 20 x 20 14 x 14 16x16 18x18 20 x 20 LIGHT HAZARD 0.10 GPM/Fr GPM PSI 30 7.2 33 8.7 40 12.8 30 7.2 33 8.7 40 12.8 N/A N/A N/A N/A N/A N/A N/A N/A 37 7.0 37 7.0 40 8.2 GROUP ORDINARY HAZARD 015 GPM/FT GPM 30 39 49 60 30 7.2 39 121 49 19.1 •••••• 60 20.7 •••• 39 49 60 39 49 60 PSI GPM PSI 7.2 12.1 19.1 28.7 • • •• •• 7.8 12.3 • • 18.4 • • 7.8 12.3 18.4 • • • • • •. • • • • • •• • FLOW CRITERIA FOR UL AND C-.IIL LISTING OF SERIES EC 14 AND EC-14 SPRINKLERS GROUP II ORDINARY HAZARD 0.20 GPM/FT 39 12.1 51••••20.7 65,•••33.7 80. • • .57.0 • • • •• • 39 • 12.1 51 20.7 Be e • 433.7 8b • 57.0 •••• • • • •• • 51 • 13.3 65••••21.6 8t1. • ••. • • • •• •-- 51 13.3 65 21.6 80 32.7 •• • • • • • • • • • • • • • • Care and Maintenance The Series EC -11 and EC -14 Sprin- klers must be maintained and serviced in accordance with the following in- structions: NOTE Before closing a fire protection system main control valve for maintenance work on the fire protection system • that it controls, permissionto shut down the affected fire protection systems must be obtained from the proper authori- ties and all personnel who may be affected by this action must be notified. Sprinklers that are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers . rnust never be painted, plated, coated, or otherwise altered after leaving the factory. Modi- fied sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers - before. during, and after installation. Sprinklers dam - aged by dropping, striking, wrench twistielippage, or the like, must be re- placed. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section): Frequent visual inspections are rec- ornrnended to be initially performed for corrosion resistant coated sprinklers, after the installation. has been com- pleted, to verify the integrity of the cor- rosion resistant coating. Thereafter, annual. 'inspections per NFPA 25 should suffice; however, instead of in- specting from the floor level a.random sampling: of close -up visual inspec- tions should. be made, so as to better determine the exact sprinkler condi- ti0.n and the.Iong term integrity of the corrosion. resistant coating, as it may be affected by the corrosive conditions present. The owner Is responsible for the in- spection, testing, and maintenance of their fire protection system and de- TFP22O vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition tp. the standards of any other authorities having . jurisdiction. The in- stalling contractor or sprinkler manu- facturer should be contacted relative to any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service. ••• • • • ••• • ••• • •• • • ••• •••• • •• •••• • •••• • TFP220 Limes Warranty Products manufactured_ by Tyco Fire Products are -warranted: seta/ 'to :the original Buyer for ten'.(1O) year against defects in material and work manship when, paid :for, and properly installed and Maintained bridal frontal . use and service. This Warranty Wilt ex pire ten (10) years from date of ship- ment by Tyco Fire Products; No..war- ranty Is given for products or components manufactured by compa- nies not affiliated by ownership. with Tyco Fire Products or for products and components which have been subject to misuse, improper installation, corro sion or which have not been:installed, maintained; modified or repaired In, cordance with applicable Standards.of the National Fire ProterAiort Associa.- don, and/or the standard& Of Any other Authorities Having Jurisdiction. Mate- rials found by Tyco Fire Products to be defective shall be either repaired or replaced, at Tyco Five Products' sole option. Tyco Fire Produots-neither as- sumps, nor authorizes any person to assume for it, any other obligation in connection with the sale of productsor parts of products. Tyco Fire Products shall not be responsible 'for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer's representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE; IN CON- TRACT; TORT, STRICT LIAEILITY QR UNDER ANY OTHER LEGAL THE- ORY, FOR INCIDENTAL, 'INDIRECT, . SPECIAL OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LABOR CHARGES, RE- GARDLESS OF WHETHER TYCO FIRE PRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO -EVENT SHALL TYCO FIRE PRODUCTS' LI- ABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. THE FOREGOING WARRANTY IS WOE IN. LIEU OF ANYY 4 NDD ALL OTHER WA RRA NTIES EXPRESS OR BIEWILINALLNillialtialiaringfi OF M4REsAN. ?m IT Y AND FIT- NESS FORA PART ICULAR P - POSE WhariPlaqing arlder nd' the full 'product= Vie: P ise:: 000111 the Spru ter ldentitication Water (SIN), quartttty, and temperature rating. Refer to the Price List for complete listing of Part Nlmbers, Contact your local distributor for avail - ability. SprInlOvrissoinblies with NPT Thread Connection - tor ((specify temperat i e rat , (specIty :Pendent:or Upright) Extended Coverage Sprinkl (specify fy fin- ish), P/N (specify - fro Table applicable). Recessed .Escutcheon: Specify: Style- (specify. 30 or 40). Re- cessed Esautcheon with (specify fin - ish), P/N ( specify). Style 3d Recessed Escutcheon Chrome P lated PSN 16-705 -8-071 white Color Coated PSN56- 705 -4011 white (RAL8010)• PSN $6-705 -3 -011 Brass Plated PSN 56- 1'05 -2 -011 Style 40 Recessed Escutcheon Chrome prated PSN 56-700-9-010 White Color Coated PSN 56- 700-4 -010 White (RAL901o)• PSN 56- 700 -3-010 Brass Plated PSN 56- 700.2 -010 •Fastem .Hemisphere sates only. Spunkier Wrench: Specify: W -Type 3 Sprinkler Wrench, • P/N 56 -895 -1 -001 Specify:. W -Type 22 Recessed Sprin- kler Wrench, P/N 56- 665 -7-001 Palge z of . - ESC AAA = 893 (for TV5237 iC11 Pendent) AAA =894 (for TY5137 K112 Upright) AAA = 895 (for TY6237 K14.0 Pep/38M AMC= 88116 jfor TY6137 • • • Kt4A Updight) •: .. • B =1 Vo Natural Bras) B = a White 1I4:4001 O))* .13 = 4'(fonfhjte PayeStr) B =r((olttad Cc d •. B =9•(folthrome l 1dtedj • CCt =135:(for 136 CCU =1.55f(for 155 °C) CCC :175 (for 176 rMC) CCC = 200 (for 200V/93 .. .. . . • .. • .. • *Eastern Hemisphere sales only. TABLE E PART NUMBERS FOR EC-11 AND EC-14 SPRINKLERS • • • • 1••• • • I.. • • • ... • ... • Page 8 of 8 • • • .. .. TYCO FIRE PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 ... • • • • . . • Tf P220 . . • • • • • • •••• • • ▪ • • . . • . • • • .. • • • •••• .. • • • • • •••• • • . • • • .. • • • • •••• • • ▪ •••• ▪ • • • • • .. • • ••• • • • • • two Fire & Building Products Technical Services: Tel: (800) 381 -9312 / Fax: (800) 791 -5500 CENTRAL Customer Service/Sales: Tel: (215) 362 -0700 / (800) 523 -6512 Fax: (215) 362 -5385 Series TY -B --- 5.6 K- factor Horizontal and Vertical Sidewall Sprinkar Standard Response, Standard Coverage General Description The Series TY-B, 5.6 K- factor, Horizon- tal and Vertical Sidewall Sprinklers de- scribed in this data sheet are standard response - standard coverage, deco- rative 5 mm glass bulb type spray sprinklers designed for use in light and ordinary hazard, commercial occupan- cies such as banks, hotels, shopping malls, etc. They are designed for instal- lation along a wall or the side of a beam and just beneath a smooth ceiling. Sidewall sprinklers are commonly used instead of pendent or upright sprinklers due to aesthetics or building construction considerations, where piping across the ceiling is not desir- able. The recessed version of the Series TY-B Horizontal Sidewall Sprinkler is intended for use in areas with a fin- ished wall. It uses a two -piece Style 10 Recessed Escutcheon. The Recessed Escutcheon provides 1/2 inch (12,7 mm) of recessed adjustment or up to 3/4 inch (19,1 mm) of total adjustment from the flush sidewall position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe nipples to the sprinklers must be cut. Corrosion resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be ob- tained when exposed to corrosive at- mospheres. Although corrosion resis- tant coated sprinklers have passed the standard corrosion tests of the appli- cable approval agencies, the testing is not representative of all possible cor- rosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suitability of these coatings for any given corro- sive environment. The effects of ambi- ent temperature, concentration of chemicals, and gas /chemical velocity, should be considered, as a minimum, Page 1 of 6 along with the corrosive nature of the chemical to which the sprinklers will be exposed. WARNINGS The Series TY-B Sprinklers described herein must be installed and main- tained in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association, in addition to the standards of any other authorities hav- ing jurisdiction. Failure to do so may impair the integrity of these devices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted relative to any questions. Model /Sprinkler Identification Numbers TY3351 - Horizontal TY3451 - Vertical Technical Data Approvals UL and C -UL Listed. FM, LPCB, and NYC Approved. (Refer to Table A for complete approval information including corrosion resis- tant status) Maximum Working Pressure 175 psi (12,1 bar) Discharge Coefficient K = 5.6 GPM/psi (80,6 LPM/barl / Temperature Ratings Refer to Table A JANUARY, 2003 • ••••• • •••• • • • • • •• • • Finishes Sprinkler: Refer to Table A Recessed Escutcheon: White Coated, Chrome Plated, and Brass Plated Physical Characteristics Frame Bronze Button Brass /Copper Sealing Assembly Beryllium Nickel w/Teflont Bulb Glass Compression Screw Bronze HSW Deflector Bronze VSW Deflector Copper Patents U.S.A. Patent Number 5,810,263 and UK Patent Number 2,347,624 may be applicable to the Series TY-B Horizon- tal Sidewall Sprinkler. TFP161 •: •• • • • • • Page 2 of 6 NOTES: 1. Listed by Underwriters Laboratories, Inc. (UL) for use in Light and Ordinary Hazard Occupancies at a 4 to 12 inch (100 to 300 mm) top of deflector to ceiling distance. 2. Listed by Underwriters Laboratories, Inc. for use in Canada (C -UL) for use in Ught and Ordinary Hazard Occupancies at a 4 to 12 inch (100 to 300 mm) top of deflector to ceiling distance. 3. Approved by Factory Mutual Research Corporation (FM) for use in Ught Hazard Occupancies at a 4 to 12 inch (100 to 300 mm) top of deflector to ceiling distance. 4. Approved by the Loss Prevention Certification Board (LPCB) at a 4 to 6 inch (100 to 150 mm) deflector to ceiling distance. 5. Listed by Underwriters Laboratories, Inc. (UL) for use In Light and Ordinary Hazard Occupancies. 6. Listed by Underwriters Laboratories, Inc. for use in Canada (C -UL:) for use in Ught and Ordinary Hazard Occupancies. 7. Approved by Factory Mutual Research Corporation (FM) for use in Ught Hazard Occupancies. 8. Approved by the Loss Prevention Certification Board (LPCB). 9. Approved by the City of New York under MEA 354 -01 -E. 10. Where Polyester Coated, Lead Coated, Wax Coated, and Wax over Lead Coated Sprinklers are noted to be UL and C -UL Listed, the sprinklers are UL and C -UL Listed as Corrosion Resistant Sprinklers. Where Lead Coated, Wax Coated, and Wax over Lead Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as Corrosion Resistant Sprinklers. * Instaled with Style 10 (1 /2° NPT) 3/4" Total Adjustment Recessed Escutcheon. ** 150 °F /66 °C Maximum Ceiling Temperature. * ** Frame and deflector only. Listings and approvals apply to all colors (Special Order). Operation The glass Bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass Bulb, allowing the sprinkler to activate and water to flow. TABLE A LABORATORY LISTINGS AND APPROVALS Design Criteria The Series TY B Horizontal and Verti- cal Sidewall Sprinklers are intended for fire protection systems designed in accordance with the standard installa- tion rules recognized by the applicable Listing or Approval agency (e.g., UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM's Loss Pre- vention Data Sheets). Only the Style 10 Recessed Escutcheon is to be used for recessed horizontal installations. TFP161 SPRINKLER FINISH (See Note 10) K TYPE TEMP. BULB LIQUID NATURAL BRASS CHROME PLATED WHITE*** POLYESTER LEAD COATED WAX COATED WAX OVER LEAD COATED 5.6 1/2° NPT HORIZ. SIDEWALL (TY3351) 135 °F /57°C Orange 1,2,3,4,9 1,2,3,9 1,2,3,9 1,2,3,9 •••• I 1"" = 9'tt,'3ff 9** 155 °F /68 °C Red 175 °F /79 °C Yellow 200 °F /93 °C Green 286 °F /141 °C Blue 1** ' 2; *, 3* r 9 ** • • 360 °F /182 °C Mauve 1, 2, 4, 9 • • • N/A • • ' • RECESSED HORIZ. SIDEWALL (TY3351p Figure 3 135 °F /57°C Orange 1, 2, 3, 4, 9 -- • • • • • • • • • • WA • • • • " ' • • • • • • • • • • - - 155 °F /68 °C Red 175F/79°C Yellow 200 °F /93 °C Green 5.6 1/2" NPT VERTICAL SIDEWALL (TY3451) Installed Pendent or UPNght 135 °F /57 °C Orange 5, 6, 7, 8, 9 5, 6, 7, 9 • • • • • • 5 7, 2 • • • • • • • - _ • - •5 Q • • • • • • 155°F/68°C Red 175 °F /79 °C Yellow 200 °F /93 °C Green 286 °F /141 °C - Blue 5**, 6 * *, 7 * *, 9** 5 * *, 6 * *, 7* *, 9 ** 360 °F /182 °C Mauve 5, 6, 8, 9 N/A Page 2 of 6 NOTES: 1. Listed by Underwriters Laboratories, Inc. (UL) for use in Light and Ordinary Hazard Occupancies at a 4 to 12 inch (100 to 300 mm) top of deflector to ceiling distance. 2. Listed by Underwriters Laboratories, Inc. for use in Canada (C -UL) for use in Ught and Ordinary Hazard Occupancies at a 4 to 12 inch (100 to 300 mm) top of deflector to ceiling distance. 3. Approved by Factory Mutual Research Corporation (FM) for use in Ught Hazard Occupancies at a 4 to 12 inch (100 to 300 mm) top of deflector to ceiling distance. 4. Approved by the Loss Prevention Certification Board (LPCB) at a 4 to 6 inch (100 to 150 mm) deflector to ceiling distance. 5. Listed by Underwriters Laboratories, Inc. (UL) for use In Light and Ordinary Hazard Occupancies. 6. Listed by Underwriters Laboratories, Inc. for use in Canada (C -UL:) for use in Ught and Ordinary Hazard Occupancies. 7. Approved by Factory Mutual Research Corporation (FM) for use in Ught Hazard Occupancies. 8. Approved by the Loss Prevention Certification Board (LPCB). 9. Approved by the City of New York under MEA 354 -01 -E. 10. Where Polyester Coated, Lead Coated, Wax Coated, and Wax over Lead Coated Sprinklers are noted to be UL and C -UL Listed, the sprinklers are UL and C -UL Listed as Corrosion Resistant Sprinklers. Where Lead Coated, Wax Coated, and Wax over Lead Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as Corrosion Resistant Sprinklers. * Instaled with Style 10 (1 /2° NPT) 3/4" Total Adjustment Recessed Escutcheon. ** 150 °F /66 °C Maximum Ceiling Temperature. * ** Frame and deflector only. Listings and approvals apply to all colors (Special Order). Operation The glass Bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass Bulb, allowing the sprinkler to activate and water to flow. TABLE A LABORATORY LISTINGS AND APPROVALS Design Criteria The Series TY B Horizontal and Verti- cal Sidewall Sprinklers are intended for fire protection systems designed in accordance with the standard installa- tion rules recognized by the applicable Listing or Approval agency (e.g., UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM's Loss Pre- vention Data Sheets). Only the Style 10 Recessed Escutcheon is to be used for recessed horizontal installations. TFP161 TFP161 Paige 3 of 6 Installation The Series TY-B Sprinklers must be installed in accordance with the follow- ing instructions: NOTES Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135 °F /57°C to 3/32 inch (2,4 mm) for the 360 °F /182 °C temperature ratings. A leak tight 1/2 inch NPT sprinkler joint should be obtained with a torque of 7 to 14 ft.lbs. (9,5 to 19,0 Nm). A maxi- mum of 21 ft. lbs. (28.5 Nm) of torque may be used to install sprinklers with 1/2 NPT connections. Higher levels of torque may distort the sprinkler inlet and cause leakage or impairment of the sprinkler. Do not attempt to make -up for insuffi- cient adjustment in the escutcheon plate by under- or over - tightening the sprinkler. Readjust the position of the sprinkler fitting to suit. The Series TY -B Horizontal and Ver- tical Sidewall Sprinklers must be in- stalled in accordance with the follow- ing instructions. Step 1. Horizontal sidewall sprinklers are to be installed in the horizontal position with their centerline of water- way perpendicular to the back wall and parallel to the ceiling. The word "TOP" on the Deflector is to face towards the ceiling. Vertical sidewall sprinklers are to be installed in the pendent or upright po- sition with the arrow on the Deflector pointing away from the wall. Step 2. With pipe thread sealant ap- plied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W -Type 6 Sprinkler Wrench (Ref. Figure 4), except that an 8 or 10 inch adjustable Crescent wrench is to be used for wax coated sprinklers. With reference to Figure 1 or 2, the W -Type 6 Sprinkler Wrench or the Crescent wrench, as applicable, is to be applied to the wrench flats. When installing wax coated sprinklers with the adjustable Crescent wrench, additional care needs to be exercised to prevent damage to the wax coating on the sprinkler wrench flats or frame arms and, consequently, exposure of bare metal to the corrosive environ- ment. The jaws of the wrench should 1 - Frame 2 - Button 3 - Sealing Assembly 4 - Bulb 5 - Compression Screw 6 - Deflector 1- 13/16" (46,0 mm) 2 -7/8 DIA. (73,0 mm) 9/16° CENTERLINE OF SPRINKLER WATERWAY (14,3 mm) '1 �s !Rii11 %Ill ill911�� 7/16' • •••• (11,1 mm) • .,, • NOMINAL • • • MAKE -IN • • • • 1-1/2° • •• • • (38,1 mm) STYLE 10 — RECESSED ESCUTCHEON WRENCH FLATS • • • •• 2-3/16' (55,6 mm) .I P R I 3 1 1/2 " ** •••• • • NPT •••• • • ••• • • • • • • • •• • • • • • •• •••• • • • •• • • • •• • • • • •• • • ••• • • • •• • ESCUTCHEON --- PLATE SEATING SURFACE * Temperature rating is indicated on deflector or adjacent to orifice seat on frame. **Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 1 5.6 K- FACTOR STANDARD RESPONSE SERIES TY-B HORIZONTAL SIDEWALL (TY3351) SPRINKLERS be opened sufficiently wide to pass over the wrench flats without damag- ing the wax coating. Before wrench tightening the sprinkler, the jaws of the wrench are to be adjusted to just con- tact the sprinkler wrench flats. After wrench tightening the sprinkler, loosen the wrench jaws before removing the wrench. After installation, the sprinkler wrench flats and frame arms must be in- spected and the wax coating re- touched (repaired) whenever the coat- ing has been damaged and bare metal is exposed. The wax coating on the wrench flats can be retouched by gen- tly applying a heated 1/8 inch diameter steel rod to the areas of wax that have been damaged, to smooth it back over areas where bare metal is exposed. NOTES Only retouching of the wax coating ap- plied to the wrench flats and frame arms is permitted, and the retouching is to be performed only at the time of the initial sprinkler installation. The steel rod should be heated only to the point at which it can begin to melt the wax, and appropriate precautions need to be taken, when handling the • • • • Page 4 of 6 heated rod, in order to prevent the installer from being bumed. If attempts to retouch the wax coating with complete coverage are unsuc- cessful, additional wax can be ordered in the form of a wax stick (the end of which is color coded). Only the correct color coded wax is to be used, and retouching of wrench flats and frame arms is only permitted at the time of initial sprinkler installation. With the steel rod heated as previously de- scribed, touch the rod to the area re- quiring additional wax with the rod an- gled downward, and then touch the wax stick to the rod approximately one -half inch away from the area re- quiring retouching. The wax will melt and run down onto the sprinkler. The Series TY -B Recessed Horizon- tal Sidewall Sprinklers must be in- stalled in accordance with the follow- ing instructions. Step A. Recessed horizontal sidewall sprinklers are to be installed in the horizontal position with their centerline of waterway perpendicular to the back wall and parallel to the ceiling. The word "TOP" on the Deflector is to face towards the ceiling. Step B. After installing the Style 10 Mounting Plate over the sprinkler threads, hand tighten the sprinkler into the sprinkler fitting. Step C. Tighten the sprinkler into the sprinkler fitting using only the W -Type 7 Recessed Sprinkler Wrench (Ref. Figure 5). With reference to Figure 1, the W -Type 7 Recessed Sprinkler Wrench is to be applied to the sprinkler wrench flats. Step D. After the ceiling has been in- stalled or the finish coat has been ap- plied, slide on the Style 10 Closure over the Series TY-B Sprinkler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. ESCUTCHEON PLATE SEATING SURFACE 1 /2° •• NPT (55,6 mm) 1 1-1/2° (38,1 mm) SHOWN PENDENT Care and Maintenance 7/16° (11,1 mm) NOMINAL MAKE -IN WRENCH FLATS The Series TY-B Sprinklers must be maintained and serviced in accord- ance with the following instructions: NOTES Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, permission to shut down the affected fire protection system must be obtained from the proper authorities and all personnel who may be affected by this action must be notified. Absence of an escutcheon, which is used to cover a clearance hole, may delay the time to sprinkler operation in a fire situation. Sprinklers that are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be be painted, plated, coated or otherwise altered after leaving the factory. Modi- fied sprinklers must be replaced. Sprinklers that have been exposed to ARROW MUST POINT AWAY FROM AND BE PERPENDICULAR TO THE BACK WALL SURFACE v41 . T . •'E -3/16° .•• • • ••• • '7 • •••• • • • TFP161 SHOWN • • • CROSS UPRIGHT • SEQ•ION -w • •••• • • • 1 - Frame 3 - Sealing 4 - Bulb • • • - Deflecto • • • 2 - Button Assembly 5 - Compression 7- Ejection Spring • Screw * Temperature rating is indicated on deflector or adjacent to orifice seat on frame. '"'''Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 2 5.6 K- FACTOR STANDARD RESPONSE SERIES TY-B VERTICAL SIDEWALL (TY3451) SPRINKLERS corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers - before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be re- placed. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section). Frequent visual inspections are rec- ommended to be initially performed for corrosion resistant coated sprinklers, after the installation has been com- pleted, to verify the integrity of the cor- rosion resistant coating. Thereafter, annual inspections per NFPA 25 should suffice; however, instead of in- specting from the floor level, a random sampling of close -up visual inspec- tions should be made, so as to better determine the exact sprinkler condi- tion and the long term integrity of the corrosion resistant coating, as it may be affected by the corrosive conditions present. • • • • • • •• • • • • • • • • TFP161 SERIES TY-B MOUNTING PLATE MOUNTING SURFACE CLOSURE 1 -1/4° (31,8 mm) 3/4° (19,1 mm) 5/8-11/4° (15,9±6,4 mm) FACE OF SPRINKLER FITTING v 1/8' (3,2 mm) 3/4° (19,1 mm) 1/4° (6,4 mm) 2 -7/8° DIA. (73,0 mm) 2 -1/4° DIA. (57,2 mm) FIGURE 3 SERIES TY-B RECESSED HORIZONTAL SIDEWALL SPRINKLER WITH TWO -PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. The in- stalling contractor or sprinkler manu- facturer should be contacted relative to any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service. Limited Warranty Products manufactured by Tyco Fire Products are . warranted solely to the original Buyer for ten (10) years against defects in material and work- manship when paid for and properly installed and maintained under normal use and service. This warranty will ex- pire ten (10) years from date of ship- ment by Tyco Fire Products. No war- ranty is given for products or components manufactured by compa- nies not affiliated by ownership with Tyco Fire Products or for products and components which have been subject to misuse, improper installation, corro- sion, or which have not been installed, maintained, modified or repaired in ac- cordance with applicable Standards of the National Fire Protection Associa- tion, and/or the standards of any other Authorities Having Jurisdiction. Mate- rials found by Tyco Fire Products to be defective shall be either repaired or replaced, at Tyco Fire Products' sole option. Tyco Fire Products neither as- sumes, nor authorizes any person to Page 5of6 WRENCH RECESS (END °A° USED FOR 1/2° NPT MODELS) FIGURE 4 W-TYPE 6 SPRINKLER JIII NCH • • • • •... • • • •• • RECESS* • • • • •• ••• • •• •• • • • •• • • • • • • • • • : o . 46H WRENCH - IN ENGAGEMERT • WITH SPRINKLER WRENCHING AREA FIGURE 5 W-TYPE 7 RECESSED SPRINKLER WRENCH assume for it, any other obligation in connection with the sale of products or parts of products. Tyco Fire Products shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer's representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CON- TRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THE- ORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LABOR CHARGES, RE- GARDLESS OF WHETHER TYCO FIRE PRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENT SHALL TYCO FIRE PRODUCTS' LI- ABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. THE FOREGOING WARRANTY IS MADE IN LIEU OF ANY AND ALL OTHER WARRANTIES EXPRESS OR JMPLIED. INCLUDING WARRANTIES OF MERCHANTABILITY AND FIT- NESS FOR A PARTICULAR PUR- POSE. • • • • Page 6 of 6 Ordering Procedure P/N 57 - XXX - X - XXX 578 575 HORIZONTAL SIDEWALL VERTICAL SIDEWALL MODEVSIN TY3351 TY3451 When placing an order, indicate the full product name. Refer to the Price List for complete listing of Part Numbers. Contact your local distributor for avail- ability. Sprinkler Assemblies with NPT Thread Connections: Specify: (Specify Model /SIN), Stand- ard Response, (specify K- factor), (specify temperature rating), Series TY-B (specify Horizontal Sidewall or Vertical Sidewall) Sprinkler with (spec- ify type of finish or coating), P/N (spec- ify from Table B). Recessed Escutcheon: Specify: Style (specify) Recessed Es- cutcheon with (specify finish), P/N (specify). 1/2° (15 mm) Style 10 Chrome Plated P/N 56- 701 -9-010 1 /2° (15 mm) Style 10 White Color Coated P/N 58- 701 -4-010 1/2° (15 mm) Style 10 Brass Plated P/N 58 -701 -2.010 1 4 9 7 6 8 SPRINKLER NATURAL BRASS WHITE POLYESTER CHROME PLATED LEAD COATED WAX COATED 286 °F /141 °C MAX. WAX OVER LEAD 286 °F1141 °C MAX. Sprinkler Wrench: Specify: W -Type 6 Sprinkler Wrench, P/N 56- 000 -6 -387. Specify: W -Type 7 Sprinkler Wrench, P/N 56- 850 -4 -001. Wax Sticks: (for retouching wrench damaged wax coating) Specify: (Specify color) color coded Wax Stick for retouching (specify tem- perature rating) temperature rated Se- ries TY-B Sprinklers, P/N (specify). Black for 135 °F P/N 56-085-1-135 Red for 155 °F ..... P/N 56 -065 -1 -155 Yellow for 175 °F P/N 56-065 -1 -175 Blue for 200 °F and 286 °F P/N 56 -065 4-288 NOTES Each wax stick is suitable for retouch- ing up to twenty-five sprinklers. The wax used for 286 °F sprinklers is the same as for 200 °F sprinklers, and, therefore, the 286 °F sprinkler is limited to the same maximum ceiling tempera- ture as the 200 °F sprinkler (i.e., 150 °F). 135 155 el75 • • 200 •••• TEMPERATURE RATING 135 °F /57 °C 155F/68°C • 175°09:0. • • • 200 °F /91°C: • •• •• 1 289; • @86 °F/141 °O • • •360 °F /1 321C • • • • • • •• •• • • • • • • • TABLEB ••.• • PART NUMBER SELECTION SERIES TY-B HORIZONTAL AND VERTICAL SIDEWALL SPRINKLERS TYCO FIRE PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 TFP161 ••• • • • • •• • • •••• • • •••• • ••• • • • •• •