Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
MC-10-970
Project Address 113 NE 105 Street Miami Shores, FL 33138 -2032 Owner Information Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL 33138 -0000 Phone: (305)795 -2204 Fees Due CCF Education Surcharge Permit Fee Scanning Fee Technology Fee Total: Amount $4.80 $1.60 $265.30 $3.00 $6.40 $281.10 Address Parcel Number 1121360050100 Block: Lot: JULIA RENNINGER 113 NE 105 Street MIAMI SHORES FL 33138 -2032 1 Contractor(s) MARNO A/C SERVICES Phone Cell Phone (305)885 -2195 Tons: 4 Additional Info: MECHANICAL Classification: Residential Approved: Yes Comments: SHOW LOCATION OF A/C UNIT ON SURVEY Date Approved: 6/9/2010: Yes Date Denied: 6/8/2010 Type of Work: A/C SPLIT SYSTEM & DUCT WORK Scanning: 1 In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Futhermore, I authorize the above -named contractor to do the work stated. Authorized Signature: Owner / Applicant / Contractor / Agent Building Department Copy Phone Pay Date Pay Type Amt Paid Amt Due Invoice # MC -5-10 -38024 06/10/2010 Check #: 30732 $ 231.10 $ 50.00 05/28/2010 Check #: 30680 $ 50.00 $ 0.00 June 10, 2010 Date Applicant JULIA RENNINGER Cell Valuation: Total Sq Feet: $ 7,580.00 0 1 Available Inspections: Inspection Type: Final Rough Duct Underground June 10, 2010 1 Inspection Number: INSP - 144655 Scheduled Inspection Date: June 17, 2010 Inspector: Perez, JanPierre Owner: RENNINGER, JULIA Job Address: 113 NE 105 Street Miami Shores, FL 33138 -2032 Project: <NONE> Contractor: MARNO A/C SERVICES Building Department Comments installation of one central a/c split system 4 tons and ductworks S Passed Failed Correction Needed Re- Inspection Fee No Additional Inspections can be scheduled until re- inspection fee is paid. Inspector Comments June 16, 2010 Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 For Inspections please call: (305)762 -4949 Permit Number: MC -5 -10 -970 Permit Type: Mechanical - Residential Inspection Type: Final Work Classification: New A/C System Phone Number Parcel Number 1121360050100 Phone: (305)885 -2195 Page 13 of 20 BUILDING PERMIT APPLICATION FBC 2004 Des , ribe Work: Is Building Historically Designated YES NO Architect/Engineer's Name (if applicable) Type of Work: ['Addition ['Alteration Bond $ Code Enforcement $ Structural Review. $ Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 Permit Type (circle): Building Electrical Plumbing Mechanical Roofing Owner's Name (Fee Sim le Titleholder) J � ;{ �/ � ; E/i f JV1 J)iij Phone it Owner's Address /' s E. ib5 67/2 &f `- Cit /4 wt 5 Shr) { State pt r i Tenant/Lessee Name Job Address (where the work is being done) 1/ , AF., /05: City Miami Shores Village County Miami -Dade Zip 55_ 13 - FOLIO / PARCEL # Contractor's Company Name MVP() A 0 „bp rL) in _Ti • Phone (46,) P43,6 1 96 — Contractor's •Address ► 0/ f I �,�F'e� / City - �a /'1 1/ States � Vl n� Z :_ State Certificate or Registration No.C/40-4 (050 Certificate of Competency No. / Value of Work For this Permit a Square / Linear Footage Of Work: DNew Qkri DPBR $ Permit No. /VC) io - 'q /0 Master Permit No. - Zip 35 lb B Double Fee $ Phone # Phone # Total Fee Now Due $ MO 2010 h r ' MO el n1► . 46. - 1 Repair/Replace ❑ De , lition * *** *** * * * * * * * * *** ** * **: *** * **** * *** *** Fees * *** * *** * *, ***** **** ** * * * *** * ****** * **,r***** Submittal Fee $ V ' Permit Fee $ Q/ 6c G CCF $ 4. CO/CC Notary $ Training/Education Fee $ • Technology Fee $ Q.40 Scanning $ 3 •00 Radon $ Zoning $ See Reverse side -+ 17c) Bonding Company's Name (if applicable) Bonding Company's Address City. State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC OWNER'S Al4FIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged Signature Signature ✓.k L .44L-- Owner or Agent The fore instrument was acknowledged before me this a o day of , 20 /o , by A 111 f<19 who is personally known to me or who has producf b 1` t e..6 mn As identification and who did take an oath. NOTARY PUBLIC: * * * * * * * * * * * * * * * ** (Revised 02/08/06) My Commission Exp { FY PIRE8 June 16, 2012 40 ) 3£ ;.0' S3 FloridallotaryService.com � k�tYr ,Y* - Irre**** pie*** *********Mfr************** **** APPLICATION APPROVED BY: The fore day of who i Contractor oij4_ instrument was acknow ed beforeAcie this 0 20 g by (An erd2 personal y, kno NOTARY PUBLIC: Sign: Print: My Co to me or who has produced as identification and who did take an oath. MMISSIDN # D079248 'iRES Jun 16, 0 6oridallotafl ce•com * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Plans Examiner Engineer Zoning • s ® c NOTICE OF COMMENCEMENT A RECORDED COPY MUST BE POSTED ON THE JOB SITE AT TIME OF FIRST PERMIT NO. 41 1C - .) 10- 910 STATE OF FLORIDA: COUNTY OF MIAMI -DADE: It r °Z I-36 - 09s ®I C Fiiteo THE UNDERSIGNED hereby gives notice that improvements will be made to certain real property, and in accordance with Chapter 713, Florida Statutes; the following information is provided in this Notice of Commencement. 1. L- • al description of property and street / address: �` � � } p`. i .� • � it, • I PP) 4l -5I L or 2. Description of improvement: z s alta4- oto o 00nir),. Lik Ono-ern 17n llcc-1-1 n et e- Ci')C l. net 3. Qvn 01 © /)11r�. Oral~.. t ' er(s) na p and addkess: . 9 h n. KA l ai rW '7TShilmil K % c. I+em ckn ote?, II iA re Interest in property: Name and address of fee simple titleholder. 4. • tractor's n - ` nd - • ress: \ .+ ,� c if, 0 ` -�_' A • --aC. n rr m ▪ � Q t m `4 D • C) o y • O �IJ m m 5. Surety: (Payment bond required by owner from contractor, if any) Name and Address: Amount of bond $ - 15811 6. Lender's name and address: 7. Persons within the state of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)7., Florida Statutes. Name and Address: 8. In addition to himself, Owners designates the following person(s) to receive a copy of the Lienor's Notice as providec in Section 713.13(1)(b), Florida Statutes. Name and Address: . Expiration date of this Notice of Commencement (the expiration date is 1 year from the date of recording unless a different date is specified) Signature of Owner Ce.(no.noue / Print Owner's Name Nnii1CA- ,lck %\e. N611 t 3 Prepared by Oi 1 fY'i(x. a � ® day of`3VN.. , D . o t l,° `7 Swom to and subscribed before me this Notary Public: Print Notary's Name My commission ex i�rg VILMA E FERNAND MY COMMISSION # DD792487 EXPIRES June 16, 2012 FIorI ervlce•cnm TAX FOLIO N6. A - _.'. IPT:1411- Tess: ( 111111011 110 �hIIIHh11tl{ll �l{ CFN 2010R0390347 OR Bk 27314 Fs 3596; (1Ps) RECORDED 06/10/2010 10 :05:09 HARVEY RUVIH, CLERIC OF COURT IIIAHI -DADE COUNTY► FLORIDA LAST PAGE ITEM PATH TUB UNIT FEE ITEM SWITCH CUTLETS UNIT FEE ITEM SPACE HEATERS UNIT FEE MET LIGHT CURETS CENTRAL HEATING 'ci k to 3ISHWASHER RECEPTACLES A/C (WIND) DISPOSAL SERVICE TEMPORARY A/C (CENTRAL) At 7d t'' DRINKING FOUNTAIN . SERVICE SIZE IN AMPS DIRT WORK 9t / toc..0 t FLOOR O1AIN SERVICE REPAIR/METER CHANGE REFRIGERATION GREASE TRAP APPLIANCE OUTLETS PROCESS AND PRESS PIPING INTERCEPTOR RANGE TOP UNDERGROUND TANKS LAVATORY OVEN ABOVE GROUND TANKS LAUNDRY TRAY WATER HEATER U.F. PRESSURE VESSELS CLOTHES WASHER MOTORS 0- 1 H' STEAM BOILERS SHOWER MJTORS OVER 1- 3 H' HOT WATER BOILERS SINK, POT /3 COM'. MJTCRS OVER 3- 5 HP MECHANICAL VENTILATION , m/' SINK, RESIDENCE MOTORS OVER 5- 8 HP TRANSPORTING ASSEMBLIES SINK: SLOP M]TCRS OVER 8- 10 HP ELEVATORS/ESCALATORS TEMPORARY WATER CLOSET MJTORS OVER 10- 25 HP FIRE 'SPRINKLER SYSTEMS OR I NAL MOTORS OVER 25-100 HP COOLING TOWERS WATER CLOSET MJTCRS OVER 100 HP VIOLATION INDIRECT WASTES A/C WINDOW RELNSPECTION WATER SUPPLY TO: 1 AIR CONDITIONERS • A/C UNIT STRIP HEATER FIRE SPRINKLER GENERATORS TRANSFORMERS • 'HEATER -NEW INST. - GENERATOZS'TRANSFORMERS HEATER - REPLACE GENERATORS TRANSFORMERS LAWN SPRINKLER -WELL SPECIAL PURPOSE SWIRAING POOL OUTLETS COM,ERCIAL WATER SERVICE SIGN TUBES SEWER CONNECTIONS ....SIGN TRANSFORMERS UTILITY -SEWER SIGN TIME CLOCK UTILITY -WATER FIXTURES SEPTIC TANK ANJENNA RELAY • TELEVISION OUTLETS DRAINFIELD, 4' TILE/RES. VIOLATION PUMP & ABANDON SEPTIC TANK REINSPECTIDH SOAKAGE PIT CU. FT. — CATCH BASIN - - DISCHARGE WELL DOMESTIC WELL AREA DRAIN l 1 Y3F INLET SOLAR WATER HEATER 'IRE STANDPIPE ! } TOL PIPING .AWN SPRINKLER SYSTEM 1 ;AS RANGE - 1 STEP, SET (GAS) AS PIPING 1 ;AN'ATPLICATION FOR BUILDING PERMIT MUST ACCOMPANT THIS ADDENDUM. IF A MASTER PERMIT HAS B. OBTAINED, THE OWNER'S NOTARIZED SIGNATURE NEED NOT BE PRESENT ON SUBSEQUENT APPLICATIONS.j PLUMBING ELECTRICAL MECHANICAL This Instrument Was Prepared By And Should Be Returned To: Julia B. Renninger 1629 North N Street Lake Worth, FL 33460 Property Appraisers Parcel Identification (Folio) Number: 11 -21- 36-005 -0100 WPBDOCS 7785646 1 WARRANTY DEED THIS WARRANTY DEED, executed as of the f day of 41 2010 by JULIA BOWES RENNINGER, a single woman, (the "Grantor "), whose mailing address is 1629 North N Street, Lake Worth, FL 33460, to ANNIKA ELAINE ASHTON, a single woman, and ERIC HERNANDEZ, a single man, as tenants in common as right of survivorship, (the "Grantees), whose mailing address is 113 N.E. 105 Street, Miami Shores, FL 33138. WITNESSETH That Grantor, for and in consideration of the sum of Ten ($10.00) Dollars and other good and valuable consideration to Grantor in hand paid by Grantees the receipt and sufficiency of which is hereby acknowledged, has granted, bargained, and sold to Grantees and Grantees' heirs and assigns forever, the following described real property situate, lying, and being in Miami_ Dade County, Florida, to wit: Lot 10, Block 201 DUNNING'S MIAMI SHORES EXTENSION NO. 1, a subdivision in the SE 'A of Sec 36, Twn 52S, Range 41E, according to the plat thereof, as recorded in Plat Book 41, Page 51 of the Public Records of Dade County, Florida. TO HAVE AND TO HOLD the same in fee simple forever. This conveyance is made SUBJECT TO the following: 1111111 11111 11111 MO CFN 201QRO333716 OR Bk 27288 Pss 4800 - 4801P (2Pss) RECORDED 05/18/2010 13:46:42 DEED DOC TAX 1,542,00 HARVEY RUVIN, CLERK OF COURT MIAMI -DADE COUNTY, FLORIDA 1. Ad valorem real property taxes and assessments for the year 2010 and subsequent years. 2. Comprehensive land use plans, zoning, restrictions, prohibitions, and other requirements imposed by governmental authority. Book27288 /Page4800 CFN #20100333716 Page 1 of 2 3. Restrictions and matters appearing on the plat or otherwise common to the subdivision. 4. Public utility easements of record. And Grantor does hereby fully warrant the title to said land, and will defend the same against the lawful claims of all persons whomsoever. IN WITNESS WHEREOF, Grantor has executed this Warranty Deed as of the day and year first above written. Signed, sealed, and delivered in the presence of: Sign of Witness 1 rA'1e. ho'a'1GS type n• i e + With 1 CAROL A BRUNOVSKY Print or type name of Witness 2 STATE OF FLORIDA COUNTY OF PALM BEACH The foregoing instrument was acknowledged before me this (,S day of , 2010, by Julia Bowes Renninger, who is personally known to me or who has produced as identification. OFFICIAL NOTARIAL SEAL: a °toy; °ee,4 CAROL ABRUNOVSKY * MY COMMSSION II DD N37291 EXPIRES: September 28, 2011 Banded T n Bud Sa,V s WPBDOCS 7785646 t Notary Public (type, print, or stamp name) OR 4K 27288 PG 4841 LAST PAGE ulia Bowes Renninger CAROL A. BRUNOVSKY G Book27288 /Page4801 CFN #20100333716 Page 2 of 2 y � A! /�s PRODUCER Westland 2608 NW MIAMI, (305)593 =`A9 South insurance 97th Ave FL 33172 Sx �^ � ��� L � ° ) , }f ➢� THIS CERTIFICATE IS ISSUED ONLY AND CONFERS NO HOLDER. THIS CERTIFICATE ALTER THE COVERAGE AFFORDED M '' N ES; 4a4 3 SI 1 116 AS A MATTER RIGHTS UPON THE DOES NOT AMEND, BY THE O t !VERAGE ' DATE (MMIDD/YY) 1/12/2010 OF INFORMATION CERTIFICATE EXTEND OF POUCIES BELOW. # A , GRANADA INS CO INSURED MARNO AIR CONDITIONING SERVICE INC 2012 WEST 73RD STREET HIALEAH FL 33016 AR49fetk,_ ., COMPANY BRIDGEFIELD EMPLOYERS INS CO COMPANY C COMPANY D , �� THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE USTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED, NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES >: LIMITS SHOWN MAY HAVE BEEN REDUCED BY TYPE OF INSURANCE PAID CLAIMS, POLICY NUMBER POLICY EFFECmE DATE (MMIDO/YY) POLICY EXPIRATION DATE (MM/DD/YY) LIMITS A GENERAL LIABILITY COMMERCIAL GENERAL LIABILITY 0185FL00005716 -2 1/7/2010 1/7/2011 A is s 2,000,000 "..-°- -e° ' CLAIMS MADE (EEI OCCUR. INJURY H ° - tx' . $ 2AQ0,000 $ 1,000,000 OWNERS & CONTRACTOR'S PROT $ 1;000 000 FII DAMAtaE g clie fire Iti DEXP(Aty+ a 1 50,000 1 all i ANY A AUTOMOBILE LIABILITY Q AUTO 0 ALL OWNED AUTOS ® SCHEDULED AUTOS 0110FL00001777 -2 1R/2010 1/7/2011 - COMBINED SING LIMIT $ 50,000 BODILY INJURY ( Per person) $ 0 HIRED AUTOS NON -OWNED AUTOS BODILY INJURY (Per accident) PROPERTY DAMAGE $ LUARMITY AU•T O AUTO ONLY - EA ACCIDENT $ OTHER THAN AUTO ONLY n � EACH ACCIDENT $ AGOREGATEi $ EXCESS LIABILTY UMBRELLA FORM ® OTHER THAN UMBRELLA FORM EA O R CE $ AGGRE GATE $ $ B EMPLOYERS' THE PR3PRIETOR/ I i ' *moats ARE xcL x' 12 /1/2009 12/1/2010 III STATUTORY LIMITS _. _ _ 6 ACCIDENT $ 1,000,000 DISEASE - POLICY LIMR 1,000,000 DISEASE- EACH EMPLOYEE _ $ 1,000,000 A PH YSICAL DAMAGE 0110FL00001777 2 117/2010 1/7/2011 COMP DED 500 COLL DED 500 DESCRIPTION OF OPERATIONS /LOCATIONSNEHICLESJSPECIAL ITEMS 2008 CHEV EXPRESS VINSIGCGG25V281245928 MECHANICAL CONTRACTOR WC ∎II- iFnr't ln . r x.s� " di^ ��uu,lat AU,.ww�µ'iatiy: Miami Shores Village Building Department 10050 N . E . 2 Ave Miami Shores, Florida 33138 at �'. +x� ®em/*a i0 ,,- � u. 1. fna. tiv�� ..�L.1.. "r�'':flF. SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, THE ISSUING COMPANY WILL ENDEAVOR TO MAIL 30 DAYS WRITTEN NOTICE TO THE CERTIFICATE HOLDER NAMED TO THE LEFT, BUT FAILURE TO MAIL SUCH NOTICE SHALL IMPOSE NO OBLIGATION OR LIABILITY OF ANY KIND UPON THE COMPANY, ITS AGENTS OR REPRESENTATIVES AUTHORIZED REPRESENTATIVE HOMERO LAVERNIA •. :,G'letl)!flO/l �€'8S'! D.B.A.: CM CTQB• Construction Trades Qualifying Board BUSINESS CERTIFICATE OF COMPETENCY 000013581 MARNO AIR CONDITIONING SERVICE INC PE'EZJUAN Is certified under the provisions of Chapter 10 of Miami -Dade County VAUD 'FOR CONTRA T N NT L09 /3o/22oj lu w NIP '3 °qualm a±i - aro z000 (s)3avw. ONU.indno Ac# 3872745 DEAR DATE BATCH NUMBER 07/24 080056729 C Eb 42 6 be CLASS A SIR CONDITIONIN C gamed below IS CERTIFIED tinder the provisions of Chaptq Expiration date: AUG 31, 2010 JUAN MARNO. A/C SERVICE' Y'NC 201210/EST 73RD STREET HAILEAH FL 33016 C RLIE CRIS' OVERNOR T U TT Tti LICENSE NB i tBPLAY ()HIRED BY LAW 1. Y fry (4 WrNif 'FLORIDA PROFESSIONAL REGULATION R Y LICENSING BOARD SEQ #L08072400635 CHUCK DRAGO INTERIM SECRETARY City of I;ialeah Business Tax Receipt Mayor Julio Robaina 2009 -10 238220 -69 No: (OLD- 1711 -2) Amount: $ 150.00 The person, firm or corp. listed here has paid the business tax required to engage in or operate the business specified subject to the regulations and restrictions of the City of Hialeah, Florida Owner: Type of Business: Plumbing, Heating, and Air- Conditioning Contractors MARNO AIR COND SERVICE, INC. 2012 W 73 ST HIALEAH, FL 33016 Validating No.: 0000 THIS IS NOT A BILL Business Location: 2012 W 73 ST Expites September 30, 2010 Planning and Zoning Criteria Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL 33138-0000 Phone: (305)795 -2204 Fax: (305)756 -8972 Miami Shores, FL 33138 - 2032 Total Job Valuation: $6,800.00 Owner's Name: JULIA RENNINGER Job Address: 113 105 Street L ontractor(s) none J rmrary MARNO A/C SERVICES (305)885 -2195 Yes Planning and Zoning Criteria and Comments Tons: 4 Classification: Residential Additional Info: MECHANICAL SHOW LOCATION OF NC UNIT ON SURVEY Issue Date: Not Issued Permit NO. MC-5-10-970 Expires:Not Issued Folio Number:1 1 21 3600501 00 Approved: No Owner's Phone: Total Square Feet: 0 Planning and Zoning Criteria Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL 33138 -0000 Phone: (305)795 -2204 Fax: (305)756 -8972 Planning and Zoning Criteria and Comments Tons: 4 Classification: Residential Additional Info: MECHANICAL Folio Number:1121360050100 Owners Name: JULIA RENNINGER Job Address: 113 105 Street Miami Shores, FL 33138 -2032 Owner's Phone: Total Square Feet: 0 Total Job Valuation: $ 6,800.00 Contractor(s) MARNO NC SERVICES Phone (305)885 - 2195 Primary Contractor Yes 1 Approved: Yes Planning and Zoning Criteria Contractor(s) Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL 33138 -0000 Phone: (305)795 -2204 Fax: (305)756 -8972 Owner's Name: JULIA RENNINGER Job Address: 113 105 Street Miami Shores, FL 33138 -2032 MARNO NC SERVICES Planning and Zoning Criteria and Comments Tons: 4 Classification: Residential Additional Info: MECHANICAL Folio Number:1121360050100 Primary Contractor Yes Approved: No Owner's Phone: Total Square Feet: Total Job Valuation: 0 $ 6,800.00 qviamcDs ProposaI-Acceptan AIR CONDITIONING SERVICE, INC. 2012 W. 73rd Street • Hialeah, FL 33016 885 -2195 • Fax: 823 -2195 LIC q CAC 042630 SUBMI STREET 113 NE 105th Street 1 I •• • • CITY. ST WE HEREBY SUBMIT SPECIFICATIONS • APJ EE'IAL4T'a E CR: PHONE 1- Installation of (1)one centraI a /r.. RhlaPm 1R nn SAAr 9- Installation of duct work 3- Installation of (13)thirteen outlets supply. • I - • 5- Permit 6- Energy calculation Price $7580.00 FPL Rebate - 780.00 Total $ 6800.00 JOB PHONE Payment to be made as follows: 50% down payment $3400.00 25% rough inspection $1700.00 25% final inspection $1700.00 Total $6800.00 ass. WE PROPOSE HEREBY TO FURNISH MATERIAL AND LABOR • COMPLETE IN ACCORDANCE WITH ABOVE SPECIFICATIONS FOR THE S PAYMENT TO BE MADE AS FOLLOWS: Thank You For Your Business. All material is guaranteed to be as specified. All work shall be completed in a workmanlike manner according to standard practices. Any alteration or deviation from above specifications involving extra costs will be executed only upon written orders, and will become an extra charge over and above the amount set forth above. We shall not be responsible for delays caused by strikes, accidents or other contingencies beyond our control. Owner to carry fire, tomado and other necessary insurance. Our workers are fully covered by Workmen's Compensation Insurance. ACCEPTANCE OF PROPOSAL The above prices, specifications, terms and conditions are satisfactory and are hereby accepted. You are authorized to do the work as specified. Payment will be made as outlined above. Date of Acceptance: Page DATE, JOB NAME JOB LOCATION PROJECT DIRECTOR AUTHORIZED SIGNATURE of Pages NOTE: THIS PROPOSAL MAY BE WITHDRAWN BY US IF NOT ACCE WITHIN DOLLARS ( $ efzeCGC{.G. DAYS. DATE OF PLANS FACSIMILE COVER SHEET TO: Arlene PHONE: FAX: (305)756 -8972 FROM: Juan Perez COMPANY: Marano A/C Service Inc. FAX: (305)823 -2195 PHONE: (305)885 -2195 DATE: 6/4/10 Paps including this Cover page: RE: MC -5410 -970 . r:i : 9:23AM�`HENRY MARINES PA �"'" � � r�r €caN : ,;Q z.2eea purtrtgors 4J r • F : ($05) 20F -42 ' IMAM ille: Ay -- -p• . _ LOT 90 BLOCK • 29'1 ONE STORY RES. # • ' CONO, sw1c • .rs.eo' • - 6 B -aQQK - 201 i. LWWrfC x'01 4' G.L.F. oM'cc P 2' LAND SURVEYORS BOUNDARY 'SURVEY $QALLt f" LOT -7 BLOCK. 201 AIMS o , 0 6 31,E oo p 2 , ,�0000ss�. HFBT Na 2 OF , 2 LOT•6 (9LOCK 201 LOT -11 BLOCK • 204 av`1i: Jun. 4. 2010 9:24AM 3332 N.W TTM STREET, SI MI %B WA P!. WO TFJ.E'PHONDI i3D”2114.E0M1 FAS:I$Af; 288-021CB DRAWN NY: IRMO SURD OF LOT 71.t 2 LOCK 201, OF DUNNING'S MIAMI moms I*XTEN$ION NO. 1, ACCORDING TO THE PLAT THE PLAT B OOK 41, 1 3E 61, OF THE PUDUC RECORDS OF MIAMI -DAD COUNTY, FLORIDA. PROPERTY APD{TIL'SS: 113 NE 10S ST, MIAMI, ESL 99188 FOR ANNIIKA MAINE ASHTON LOCATION SI TC�" I .S IQ 1" a NTg% Nova Surveyors, Inc. .AND SURVEYORS .... —a•- -- •---_. -, __. - _ ■ Meow., . - _.�.� me OMR Ad ARC AM a AIR CONFr"ONFA PAD AE = ANCHOR El KNEW Wti= ALUMINIUA IMP A1$ ALUMINIUh' 3HED ABPH. It ASPMALT Ama000KODDIER S.C.R. • Ea'ROWARO WORDY REOOROI meth nBE H?AA.K 10.3. • PAIRS OFIMOWS CA c,E,, T c.R,W, =CONCRETI SLOOP. WALL CH a oNoRD C14,0, t CHORD BE 1RING GL ■CLEAR G.LF. = DAMN L1N• re CAE. = CANA1. MA 1 •17NAI ICE EASEMENTTt CONC. a COMM C.P, • CONCRE1 �OiXCER ms. • CCNC R TU BLAB 4l. = DPAINAO£ FAsavENT D.M, . • °RAMOS t•IAINTRNANDE CAREMEtc DRIVE • OBRIBWAI ENCR = ENCROACI MINT E. T.P, a magic 7 •4ANSF MIER PAD F,P,4. ¢ PINIONED n a0R R WATTON P.H. D Pin HV84!NT F. LP. = rQUNO IPN hI P! I F.I.R. u POUND Ulm ROD F.N.= FOUND NA F.N.C. • POUND NA L s DM: • - THEM MAT BE RAIN IRO) WORDED INTRO 0 MORDO NC71 SHOWN Oh TIM SUAVEY. . THE PumpOAB OP 71 .13 SURVEY IS FOR uss W ORrAININO TRta vu RANCO Ate Ru'!A!'ICIND, AND ANGULO NOT OR utIRD FoJ3 OONSTRL trTION o URPCISI , - E JSARIRWATIONS ABET RAT ofMI HA VETOha TO DL;100Mul! RECORDED tN$TRU IPANY, AfrF•E 4T N tee Pig men TH19 SURVEY Is jy� MAD ! TO 01NDIC!1TIO, LIMITATIONS, RESTRICTIONS, RATIONS on CEMENTS OP TT!ORD ANA L@DAE p - PROM= SY CLIENT OR AMODIO ,TFLE COMPANY. aovNDAM1 &Met I 8,1 CAROM AND 10 A IMPNIO ROPROOIRTAlION OF TM SURVEYWORs PCRPORMEB IN - +HE FIELD. COULD 81 DRAW J ATA 4140 AN ANO /DA NOT 70 SCA!,p, 8A811D1L+>•ITS AS RHO !'IN ARR PEpt FLAT ROOK OT EAINISS SOWN. - rig TERM :'+ASHY' `MEANS I UNE AND AteVE AROUND ENCROACHMENT., - AROWTE.B% SHALL IBRIFTrAPENO RECUIATIONS, MS REVRICTIONO AND E!TlAOKS. AND 'ma OEM RE0PON8®I.E FOR8URMhTriNG PUT FLANS Yew TKO Opp INFORMATION PORTHEIR APPROVA LFOAAUT140102IlTTON ATTNb!ZI IEN IN MM.! C lly.. Qt lemma Iwo as er,ueamsv ww,n, w=. I, ... . uw• �r..., -- r- . - PPM* FEDERAL NATIONAL INSURANCE PROoPANI IN.UEO. • EASEMENT' AND WRNS us, • I.OMAT FLOCK &RVATION LA1LE ■ tme MNNTINANOE EMINENT I..P, • LIONT POLE Mis A MANHOLE DISTANCE F, NOT A PARTOft Mg • DATA!► QBODEhG VERTICAL N,T',A = NOT TO SCALE CAL u OVIOSSEAD UTILt1Y LINES V.RS, • O RECORD 000)C OWL • LA S S O ON N RO ■ PO1NTOf CURVET ►.tr • moPESSIONAL LAND SuAVEYOrt PANS.. • POINT of BPQIMh(NO P.0,0.,- POINT' QF CDMMENCIEMEN ` PP. a POWER POLE, P.P,. • POOL PUMP SLAB P,RO, • POINT OF REVER$♦a CURVE PERM - ANTREPERBNCE !J ?. • POINT OF TANGENCY Mot • PAVENOT tVt' • PAR!MAY R+ RECORD DISTANCE HENRY MARINES PA awn RADIUS OF RADIAL RGE, = PANG. R.P. RADNB POINT R.O.E. :t ROOF OVERHAND EASEM4NT MT „ RIOHTAF.WAY SEC. ,1 SECTION &L P, • SET MON PM L.O. /13844 8WK': filD WALK T:- TMCIENT 7WP'• TOWNSHIP U.E. a tmLKY Mama U.P. o UTILITY POLE , ,M, a WATER MaTEIt W.R. • WOOD ROOF w.e... WOOD SW 4. ANGLO A 'I e! NTRAL Q COWER LINE S • MONUMRMT L!NE IIND TTrICAL ▪ OAO zcze C.I.S. = WALL -$--R. O.LP, u WAIN - a--�f' L. • RZON w,P, • WOOD ▪ 410 • 1 IP $r141, SEARIN , E►Y SAID PLAT moment NOT THEN 2) THIS IS A SPECIFIC $ THE CLOSURE PI THE MOO FT. 4 ,BLVArl C0UIJNFY. I - ELK I MOW CERTIFY: THAT THE PROPERTY 8 $CIi1 AND DRAM CO M 1 S WITI4 Tes AS OTT FORTH EY TNR FL PROFE;*IONALLAND FLORIDA AOMINIBTRAIWE• FLCR10A5TATUTP.A, No.0631 P• 3 suR EY 4Q •1 Q-000051 2.1 8HEET 1 OF 2 F AS RECORDED IN 40' .10 1 O • z 111 04 vi 1,I,j I I 4O' (4 � �- S ”, zee — tb. • .o UNES KFFENCE ce CE FILEVAIONs !Maim TOM AMMO TH8 OPOR1PTI0N OF THE I►408 ME REM O= TO WART 01 J/WRY 18 ABOVE AM RIVERA%) TO FEET OF N.R3.1T.D. OF 49.<^O. 'SOUNcIART SURVEY OF NENEON, AR RECENTLY !:R MYEUPERVISION, ? CMNPCAL STA0.RAAM BOARD OP RI IN CHAPTER e1 OITA, PUNSUANV TO 472427, aaa nU4g, , .•s a - IIVA....I, ,.., Fi hUErnI4G ANDA7+t FOUN11:1 2N8, FENCE OWN R8NIF NOT OBI MEM - '?+18 PLAN Off KIRVET ta BEEN PTIPARER Patna vex OF ilia walla NAMED, • HEREON, Tme tasTSFICIe:t IO NOT WIND TO • THE atilWarort MAi i I•D F 1. PN TE 1 AS VINO ACCURACYOFTHE INFORMATION MON. '11 BI LOCAL CALM* - AGENT *HOMO BE CON feIE P FORMARMATION., THE FNP FLC011 MOB *WE DE51 MATES TFBI HO VEN DESCRIBED L A R D TO T i E s m a r m 1 t ZOHM X C O M M U N r rn P A A 1 R t 1 8 U F F N 1 O 2 L DATE eF PM oe111f20n use now ELaVA7IOP.! NM. CERTTFID TO: ANNICA ELAINE ASHTON LAW OFFICES OF f111NRY Es MARINES, PA OLD REPUBLIC NAT ONAL TITS, tNSU lANCR COMPANY PROSPECT MOR1G OE, U.0 ISAOA . ,� ' .. �ry aye! Crum mi, m !!'iATII Ott MI.,019DA �1AI.IA COPiHB � THI9 BURte'Y 44+LE. BEAR THE 0O8140 5 OF THE ArreWriNO LANE REVIEIVI 3N NEVIBEC ,,....r.... I rAL%c .1 .1 SURW, NOTE A) ( Utility Oat Encroaching onto Subject propoily on the North side. I 1 :1 • Tit( P.! • 1ry JR 3sOwsin rIMArdeil in the Ptilitio Records riot Awn on tin Survey. 1 • 'nit, filititory t)F $11•+itky. is for no* in ob,itig Title inguratm and Firms:1m avid thlold not no used fOr Construction PurFars* 71p .;. mum pt4 ART _ 4 1 1 1 11 , +�r iun Uu' 9 :23Ah9� HENRY , MARINES PA "'r - IMP HON. E (X0) 2042000 .� pururt, .. N o . 0 6 31 °P , 2 /�! r� `„ PAx: pm) 264-.1229 Y� 7 4 •-�TVr I�i Mlr�ffi�� LAND SURVEYORS FEET Mu. 2 OF .....2_ _____AIT s uR.v, Y 1, scALB b y" a 20► MO 7x422' OAr I..CT BLOCK 201 a.04x 4' C.L.F LOTS T BLOCK 2pg ,.QT - 11 LOOK 201 tC. E'S sb Est cE AN /KA 4 /7 c1 ,4 Elie ZiuA .i l�EZ // 3 Af- / 0.5 .- 144 Sf 6 4/ /�•�.?/ SL co ces, �C 33 /3d' MARNO AIR CONDITIONING, INC, Service & Installation 2012 West 73 Sheet Hialeah, 1=907 33016 Equipment Schedule Brand Rheem Cond. Unit 14AJM49A01 Air handler Unit RHLLHM4821JA KW 10 Seer 16.00 EER 1300 Freon 410 Total BTU 46,000 Sens 31250 HP 1/3 Voltage 208/230/1 Ari page # 3799432 Tons 4 Project Name: Annika Ashton and Eric Hernandez Builder Name: Street: 113 NE 105 Street Permit Office: City, State, Zip: Miami Shore , Fl , 33138- Permit Number: Owner. Jurisdiction: Design Location: FL, Miami 1. New construction or existing New (From Plans) 2. Single family or multiple family Single- family 3. Number of units, if multiple family 1 4. Number of Bedrooms 0 5. Is this a worst case? No 6. Conditioned floor area (ft 1386 7. Windows Description Area a. U- Factor: Sgl, U =0.55 256.77 ft SHGC: SHGC =0.60 b. U- Factor: N/A ft2 SHGC: c. U- Factor: N/A ft SHGC: d. U- Factor: N/A ft2 SHGC: e. U-Factor: N/A ft2 SHGC: 8. Floor Ty Insulation Area a. Slab -On -Grade Edge Insulation R =10.0 1386.00 ft2 b. N/A R= ft c. N/A R= ft2 9. Wall Types Insulation Area a. Concrete Block - Int Insul, Exterior R =5.0 1205.30 ft b. Concrete Block - Int Insul, Adjacent R =5.0 183.75 ft c. N/A R= ft2 d. N/A R= ft2 10. Ceiling Types Insulation Area a. Under Attic (Vented) R =19.0 1386.00 ft b. N/A R= ft c. N/A R= ft 11. Ducts a. Sup: Attic Ret: Attic AH: Interior Sup. R= 6, 277.2 ft 12. Cooling systems • • • • • • a. Central Unit • • . • Cap:43'6 /hr • ••• • •• V :16 •• • 13. Heating systems •••••• a. Electric Strip Heat ...'• • Cap o .2.0 IjBtu/hr •••••� • • VP: • 14. Hot water systems • •„• • • • ,. • • �• • a. Electric • • . • • • Cap. t�G gallo92 •••••• EG:0.92 b. Conservation features • • • • • None • • ;••••• • 15. Credits • • • • • • • • Vseat • • •••• • • • •,..: oo ' • • • ' ••:••, , • • •∎ • •••• :••• • Total As -Built Modified Loads: 31.26 Glass /Floor Area: 0.185 PASS Total Baseline Loads: 37.06 I hereby certify that the plans and specifi tions covered by this calculation are in complian with th - Florida Energy Code. PREPARED BY 0 ► CD Review of the plans and . specifications covered by this t m calculation indicates compliance F ° 4, , = �� with the Florida Energy Code. arrf ' s Before construction is completed�� this building will be inspected for .; compliance with Section 553.908 *' Florida Statutes. ; b BUILDING OFFICIAL DATE. , - .. — I hereby certify that this with the Florida Energy OWNER/AGENT' building, as designed, is in compliance Code. DATE DATE FORM 1100A -08 'FLO`RIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs Residential Performance Method A - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory- sealed in accordance with N1110.A.3. 5/27/2010 1:57 PM EnergyGauge® USA - FlaRes2008 Page 1 of 5 PROJECT Title: Annika Ashton and Eric Hema Bedrooms: 0 Adress Type: Street Address Building Type: FLAsBuilt Conditioned Area: 1386 Lot # Owner. Total Stories: 1 SubDivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: 113 NE 105 Street Permit Office: Cross Ventilation: County: Dade Jurisdiction: Whole House Fan: City, State, Zip: Miami Shore , Family Type: Single- family Fl , 33138 - New/Existing: New (From Plans) Comment: CLIMATE / IECC Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site Zone 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Miami FL_MIAMI_INTL_AP 1 51 90 75 70 149.5 56 Low FLOORS V # Floor Type Perimeter R -Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio 160.1 ft 10 1386 ft 0 0 1 -s.• • • ROOF e •••• • • • - s•- •i / Roof Gable Roof Solar ° be ck • • •. • •••• V # Type Materials Area Area Color Absor. Tested • Tnsel. • Pitch • ••••• 5/27/2010 1:57 PM EnergyGauge® USA - FlaRes2008 Page 2 of 5 5/27/2010 1:57 PM EnergyGauge® USA - FlaRes2008 Page 3 of 5 DOORS V # Omt Door Type Storms U -Value Area 1 S Wood None 0.460000 20 ft WINDOWS Orientation shown is the entered, asBuilt orientation. V # Omt Frame Overhang Panes NFRC U- Factor SHGC Storms Area Depth Separation Int Shade Screening 1 2 3 4 5 6 7 8 9 10 N Metal N Metal N Metal N Metal N Metal E Metal S Metal S Metal W Metal NW Metal Single (Clear) Yes 0.55 0.6 N 13.10416 3 ft 0 in 2 ft 0 in HERS 2006 Single (Clear) Yes 0.55 0.6 N 4.796875 3 ft 0 in 2 ft 0 in HERS 2006 Single (Clear) Yes 0.55 0.6 N 12.5 ft 3 ft 0 in 2 ft 0 in HERS 2006 Single (Clear) Yes 0.55 0.6 N 40 ft 3 ft 0 in 2 ft 0 in HERS 2006 Single (Clear) Yes 0.55 0.6 N 38.62083 3 ft 0 in 2 ft 0 in HERS 2006 Single (Clear) Yes 0.55 0.6 N 36 ft 3 ft 0 in 2 ft 0 in HERS 2006 Single (Clear) Yes 0.55 0.6 N 60 ft 3 ft 0 in 2 ft 0 in HERS 2006 Single (Clear) Yes 0.55 0.6 N 32.375 ft 3 ft 0 in 2 ft 0 in HERS 2006 Single (Clear) Yes 0.55 0.6 N 6.5 ft 3 ft 0 in 2 ft 0 in HERS 2006 Single (Clear) Yes 0.55 0.6 N 12.87361 3 ft 0 in 2 ft 0 in HERS 2006 None None None None None None None None None None INFILTRATION & VENTING / V Method - Forced Ventilation - Rdri time SLA CFM 50 ACH 50 ELA EgLA Supply CFM ExIta f CCM • Fracricin • • Fan . . was .: Default • 0.00036 1309 6.91 71.9 135.1 0 cfm Int r 0 • •••••• _ • t• • • • ' • i GARAGE • •••• • • •••■ ••.. ••1•4i, ...•I V # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Ex cseQ Wall Insul •••• 1 270.6 ft 270.6 ft 64 ft 8.2 ft • • • •. Invalid) • • • - •_ = • • • .. 1 COOLING SYSTEM • • • • V # System Type Subtype Efficiency Capacity Air Flow SHR • • Ducts 1 Central Unit None SEER: 16 43.59 kBtu/hr 1308 cfrn 0.75 sys#0 HEATING SYSTEM V # System Type Subtype Efficiency Capacity Ducts 1 Electric Strip Heat None COP: 1 21.96 kBtu /hr sys#0 HOT WATER SYSTEM # System Type EF Cap Use SetPnt Conservation 1 Electric 0.92 40 gal 30 gal 120 deg None 5/27/2010 1:57 PM EnergyGauge® USA - FlaRes2008 Page 3 of 5 a SOLAR HOT WATER SYSTEM V FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS / — Supply — — Retum — Air Percent V # Location R -Value Area Location Area Leakage Type Handler CFM 25 Leakage QN RLF 1 Attic 6 277.2 ft Attic 69.3 ft Default Leakage Interior % (Default) (Default) TEMPERATURES Programable Venting Thermostat: Jan X Jan Y X Feb X X� Mar Ceiling 'X Apr Fans: X� May [XX� Jun 'X Jul 'X Aug Aug X� Sep X Oct ct ' Nov X� Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 • • • ilf$ 78 7'8• • PM 78 78 78 78 78 78 78 78 78 78 • ZS • ; • Heating (WD) AM 66 66 66 66 66 68 68 68 $8 .• • 68 • .66 68 • • PM 68 68 68 68 68 68 68 68 68 • • 68 • • ,'66; 8@• , Heating (WEH) AM 66 66 66 66 66 68 68 68 88':" 68 68 48•••• ' PM 68 68 68 68 68 68 68 68 68 68 _ 6tj 66 •••• • • •••• ••••. •• •• •.•••. • . • • 4100 •• • •.•. • .100 j 1 110. • • • • .00.0• • • •.•••• • • 1 010•• • • • • • •• . • • • • . •• • •••• • • 5/27/2010 1:57 PM EnergyGauge® USA - FlaRes2008 Page 4 of 5 COMPONENTS SECTION REQUIREMENTS CHECK Water Heaters NI 112.AB.3 Comply with efficiency requirements in Table NI 12.ABC.3. Switch or clearly marked circuit breaker (electric) or cutoff (gas) must be provided. External or built -in heat trap required. Swimming Pools & Spas NI112.AB.2.3 Spas & heated pools must have covers (except solar heated). Non - commercial pools must have a pump timer. Gas spa & pool heaters must have a minimum thermal efficiency of 78 %. Heat pump pool heaters shall have a minimum COP of 4.0. Shower heads N 1112.AB.2.4 Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG. Air Distribution Systems NI110.AB All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, sealed, insulated and installed in accordance with the criteria of Section NI 110.AB. Ducts in unconditioned attics: R -6 min. insulation. HVAC Controls NI 107.AB.2 Separate readily accessible manual or automatic thermostat for each system. Insulation NI104.AB.1 N1102.B.1.1 Ceilings -Min. R -19. Common walls -frame R -11 or CBS R -3 both sides. Common ceiling & floors R -11. COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK Exterior Windows & Doors NI 106.AB.1.1 Maximum: .3 cfm /sq.ft. window area; .5 cfm /sq.ft. door area. Exterior & Adjacent Walls NI 106.AB.1.2.1 Caulk, gasket, weatherstrip or seal between: windows /doors & frames, surrounding wall; foundation & wall sole or sill plate; joints between exterior wall panels at comers; utility penetrations; between wall panels & top/bottom plates; between walls and floor. EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends from, and is sealed to, the foundation to the top plate. Floors NI106.AB.1.2.2 Penetrations /openings > 1/8" sealed unless backed by truss or joint members. EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed to the perimeter, penetrations and seams,.., Ceilings NI106.AB.1.2.3 Between walls & ceilings; penetrations of ceiling plane to top floo ?;•••• • ••• around shafts, chases, soffits, chimneys, cabinets salad t$ • • • ; continuous air barrier; gaps in gyp board & top plate; antic %cress. • "0 EXCEPTION: Frame ceilings where a continuous infil ValiQrg barrier • • • 1 is installed that is sealed at the perimeter, at penetrations tnd • • ..• seams. • • • • • • • •• .« •■•• .4 Recessed Lighting Fixtures N1106.AB.1.2.4 Type IC rated with no penetrations, sealed; or Type IQ pjrofl -IC . • • ., rated, installed inside a sealed box with 1/2" clearancg$3 "•from • ' insulation; or Type IC with < 2.0 cfm from conditioned space, . ' , tested. • • • • ... • • Multi -story Houses NI 106.AB.1.2.5 Air barrier on perimeter of floor cavity between floors. : I Additional Infiltration reqts N1106.AB.1.3 •••• Exhaust fans vented to outdoors, dampers; combustion s • heaters comply with NFPA, have combustion air. •••• • FORM 1100A -08 7 M 5/27/2010 1:57 PM Code Compliance Cheklist Residential Whole Building Performance Method A - Details ADDRESS: 113 NE 105 Street Miami Shore, FI, 33138- PERMIT #: 1 INFILTRATION REDUCTION COMPLIANCE CHECKLIST OTHER PRESCRIPTIVE MEASURES (must be met or exceeded by all residences. EnergyGauge® USA - FlaRes2008 Page 5 of 5 • • ••• • ••• • •• • •• •••• • • ..•• • •••• • PROJECT Title: Annika Ashton and Eric Herna Bedrooms: 0 Adress Type: Street Address Building Type: User Bathrooms: 0 Lot # Owner: Conditioned Area: 1386 SubDivision: # of Units: 1 Total Stories: 1 PlatBook: Builder Name: Worst Case: No Street: 113 NE 105 Street Permit Office: Rotate Angle: 0 County: Dade Jurisdiction: Cross Ventilation: City, State, Zip: Miami Shore , Family Type: Single- family Whole House Fan: Fl , 33138 - New /Existing: New (From Plans) Comment: CLIMATE Design Design Temp Int Design Temp Heating Design Daily Temp Location Tmy Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Miami FL MIAMI_INTL AP 51 90 70 75 149.5 56 Low UTILITY RATES Fuel Unit Utility Name Monthly Fixed Cost • •4IU • nit • ••••• Electricity kWh Florida Average 0 • • • • •• • 0 • Q9 • • Natural Gas Therm Florida Average 0 • • • • 01./ � ••••• • Fuel Oil Gallon Florida Default 0 ••• • • • • Propane Gallon Florida Default 0 •••••• 1 4 • •••• SURROUNDINGS • • •• • . -- %c�T _ Shade Trees AdJit;Buildings '• • Width ' Distancg Omt Type Height Width Distance Exist Height • •.•. • . N None Oft Oft Oft Oft ' •Oft •••••• Oft :•• NE None Oft Oft Oft Oft : • •••• ' E None Oft Oft Oft Oft '• Oft '•••• Oft SE None Oft Oft Oft Oft Oft Oft S None Oft Oft Oft Oft Oft Oft SW None Oft Oft Oft Oft Oft Oft W None Oft Oft Oft Oft Oft Oft NW None Oft Oft Oft Oft Oft Oft FLOORS # Floor Type Perimeter R -Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio 160.1 ft 10 1386 ft 0 0 1 ROOF Roof Gable Roof Solar Deck # Type Materials Area Area Color Absor. Tested Insul. Pitch 1 Gable or shed Composition shingles 1501 ft 288 ft White 0.96 No 0 22.6 deg ATTIC # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 1386 ft N N Building Input Summary Report 5/27/2010 1:58 PM EnergyGauge® / USRFSB v2.8 Page 1 of 4 5/27/2010 1:58 PM Building Input Summary Report EnergyGauge® / USRFSB v2.8 Page 2 of 4 CEILING # Ceiling Type R -Value Area Framing Fraction Truss Type 1 Under Attic (Vented) 19 1386 ft 0.11 Wood WALLS Wall orientation below is as entered. Actual orientation is modified by rotate angle shown in "Project" section above. # Ornt Adjacent To Wall Type Cavity Width Height Sheathing Framing Solar R -Value Ft In Ft In Area R -Value Fraction Absor. 1 N 2 E 3 S 4 W 5 NW 6 S 7 W Exterior Concrete Block - Int Insul Exterior Concrete Block - Int Insul Exterior Concrete Block - Int Insul Exterior Concrete Block - Int Insul Exterior Concrete Block - Int Insul Garage Concrete Block - Int Insul Garage Concrete Block - Int Insul 5 38 6 8 2 314.42 ft 0 0.3 5 46 0 8 2 375.67 ft 0 0.3 5 43 1 8 2 351.85 ft 0 0.3 5 13 0 8 2 106.17 ft 0 0.3 5 7 0 8 2 57.17 ft 0 0.3 5 11 0 8 2 89.83 ft 0 0.3 5 11 6 8 2 93.92 ft 0 0.3 DOORS # Omt Door Type Width Height Storms U -Value Ft In Ft _•'M' • Area. • •. 1 S Wood • • None 0.46 3 • 0 6 .• 8.• 20 ft •• • - • • .•• � WINDOWS 4,41 • • .... • # Ornt Frame Panes NFRC . Overhang •••• :'• • .•••■ • Area Depth Separatio • I t nor Shade. . Screenies • •' U- Factor SHGC Storm n � 1 N 2 N 3 N 4 N 5 N 6 E 7 S 8 S 9 W 10 NW Metal Single (Clear) Yes Metal Single (Clear) Yes Metal Single (Clear) Yes Metal Single (Clear) Yes Metal Single (Clear) Yes Metal Single (Clear) Yes Metal Single (Clear) Yes Metal Single (Clear) Yes Metal Single (Clear) Yes Metal Single (Clear) Yes 0.55 0.6 N 13.1 ft 3 ft 0 in 2 ft 0 in rapes/blinAs • '6xterior 1664 .. •. • 0.55 0.6 N 4.8 ft 3 ft 0 in 2 ft 0 in • • pj ' . s/blinds 'Exterior 100 • 0.55 0.6 N 12.5 ft 3 ft 0 in 2 ft 0 in : Drapes/blinds• • Eftt1'rior 109% • 0.55 0.6 N 40 ft 3 ft 0 in 2 ft 0 in : Dr4es/blind s • •6rt e rior 100% 0.55 0.6 N 38.62 ft 3 ft 0 in 2 ft 0 in Drapes/blinds •'erior 100% 0.55 0.6 N 36 ft 3 ft 0 in 2 ft 0 in Drapes/blinds Exterior 100% 0.55 0.6 N 60 ft 3 ft 0 in 2 ft 0 in Drapes/blinds Exterior 100% 0.55 0.6 N 32.38 ft 3 ft 0 in 2 ft 0 in Drapes/blinds Exterior 100% 0.55 0.6 N 6.5 ft 3 ft 0 in 2 ft 0 in Drapes/blinds Exterior 100% 0.55 0.6 N 12.87 ft 3 ft 0 in 2 ft 0 in Drapes/blinds Exterior 100% INFILTRATION & VENTING Method SLA CFM 50 ELA - Forced Ventilation - Terrain/Wind EqLA ACH ACH 50 Supply Exhaust Run Time Shielding Best Guess 0.00050 1818 99.8 187.7 0.345 9.60 0 0 0 Suburban / Suburban GARAGE # Floor Area Roof Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 270.6 ft 270.6 ft 64 ft 8.2 ft (invalid) MASS Mass Type Area Thickness Furniture Fraction No Added Mass 0 ft 0 ft 0.3 5/27/2010 1:58 PM Building Input Summary Report EnergyGauge® / USRFSB v2.8 Page 2 of 4 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Ductless 1 Central Unit None SEER: 16 43.59 kBtu /hr 1308 cfm 0.75 False HEATING SYSTEM # System Type Subtype Efficiency Capacity Ductless 1 Electric Strip Heat None COP: 1 21.96 kBtu /hr False HOT WATER SYSTEM # System Type EF Cap Use SetPnt Credits gal gal deg DUCTS — Supply — — Retum — Air Percent # Location R -Value Area Location Area Number Leakage Type Handler CFM 25 Leakage QN RLF 1 Attic 6 277.2 ft Attic 69.3 ft (invalid) Default Leakage Interior (Default) (Default) TEMPERATURES Programable Co olin Venting Thermostat: X Jan Y Xi %1:1) Fe Ceiling Apr X Mar ixiApr Fans: N Ma May kip, J Jul J Au Aug S e • S •,• • • ct ge ••••• • •• ti X N . • • • •' 'D. • ' X E oo Thermostat Schedule: HERS 2006 Reference Hours •••• Schedule Type 1 2 3 4 5 6 7 8 9.... •• • • • • 1 • •.,, 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 • : • • 80 PM 80 80 78 78 78 78 78 78 78. • • • 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78; PM 78 78 78 78 78 78 78 78 78. 18 Heating (WD) AM 66 66 66 66 66 68 68 68 68',, • • 06 PM 68 68 68 68 68 68 68 68 68 •• 6.8 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 • . $a . • 78 • 78 • • •7 • • 641• • •66 68 66 8C?" 78 78 • •x• 78 • 68 • 66 68 66 Building Input Summary Report 5/27/2010 1:58 PM EnergyGauge®/ USRFSB v2.8 Page 3 of 4 • Building Input Summary Report APPLIANCES & LIGHTING Appliance Schedule: HERS 2006 Reference Schedule Type 1 Hours 2 3 4 5 6 7 8 9 10 11 12 Ceiling Fans (Summer) AM % Released: 100 PM Annual Use: 0 kWh/Yr Clothes Washer AM % Released: 60 PM Annual Use: 0 kWh/Yr Dishwasher % Released: 60 Annual Use: 0 kWh/Yr Dryer % Released: Annual Use: Lighting % Released: Annual Use: Miscellaneous % Released: Annual Use: Pool Pump % Released: Annual Use: Range % Released: Annual Use: Refrigeration % Released: Annual Use: Well Pump % Released: Annual Use: AM PM AM 10 PM 0 kWh/Yr AM 90 PM 455 kWh/Yr AM 90 PM 760 kWh/Yr AM 0 PM 0 kWh/Yr AM 100 PM 0 kWh/Yr AM 100 PM 775 kWh/Yr AM 0 PM 0 kWh/Yr 0.65 0.65 0.65 0.65 0.65 0.65 0.65 0.33 0.33 0.33 0.33 0.33 0.33 0.33 0.33 0.33 0.33 1 0.9 0.9 0.9 0.9 0.9 0.65 Peak Value: 0 Watts 0.105 0.081 0.047 0.047 0.081 0.128 0.256 0.57 0.849 1 0.977 0.872 0.779 0.698 0.605 0.57 0.581 0.57 0.57 0.57 0.57 0.488 0.43 0.198 Peak Value: 0 Watts 0.139 0.05 0.028 0.024 0.029 0.09 0.169 0.303 0.541 0.594 0.502 0.443 0.377 0.396 0.335 0.323 0.344 0.448 0.791 1 0.8 0.597 0.383 0.281 Peak Value: 0 Watts 0.2 0.1 0.05 0.05 0.875 0.85 0.8 0.625 Peak Value: 0 Watts 0.16 0.15 0.16 0.18 0.23 0.45 0.4 0.26 0.19 0.16 0.17 0.25 0.27 0.34 0.55 0.55 0.88 1 Peak Value: 149 Watts 0.48 0.47 0.47 0.47 0.52 0.5 0.5 0.5 Peak Value: 139 Watts 0 0 0 0 1 1 1 1 Peak Value: 0 Watts 0.057 0.057 0.057 0.057 0.457 0.343 0.286 0.4 Peak Value: 0 Watts 0.85 0.78 0.75 0.73 0.88 0.85 0.85 0.83 Peak Value: 106 Watts 0.05 0.05 0.05 0.05 0.1 0.1 0.1 0.1 Peak Value: 0 Watts 0.05 0.075 0.2 0.375 0.5 0.8 0.95 1 0.625 0.6 0.575 0.55 0.625 0.7 0.65 0.375 0.16 0.12 0.11 0.86 0.51 0.28 0.47 0.47 0.64 0.71 0.67 0.61 ..(1.65 0.53 0.59 0.73 0.79 0.99 1 0.96 • • l l O W " : • • • • • • •• • • • • • • • 0 0 0 0 4••••• 1 "1 b 1 0 0 0 0 q••:•• 0 C •• • ••••• • • •• .•• 0.057 0.114 0.171 0.286 0.333∎••4.343 • 0.34 0.4••• . 0.571 1 0.857 0.429 0.286• • • 19729 .6:01.. 0.114• • • •• •• • 0.73 0.73 0.75 0.75 0.8; .0.8 • 0.8 0.88 0.95 1 0.98 0.95 0.93 :AV 0.85 • • • • • • •• .• • • • •• • 0.05 0.05 0.1 0.1 0.1 0.1 Oft"' 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 ••• • 0••• • 5/27/2010 1:58 PM EnergyGauge® / USRFSB v2.8 Page 4 of 4 • • • • • • •• • •• • " ENERGY PERFORMANCE LEVEL (EPL) 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ft 7. Windows*" a. U- Factor: SHGC: b. U- Factor: SHGC: c. U- Factor: SHGC: d. U- Factor: SHGC: e. U- Factor: SHGC: N/A N/A N/A 8. Floor Types a. Slab -On -Grade Edge Insulation b. N/A c. WA DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 84 The lower the EnergyPerformance Index, the more efficient the home. Description SgI, U =0.55 SHGC =0.60 N/A 113 NE 105 Street, Miami Shore, FI, 33138- New (From Plans) Single- family 1 0 No 1386 Area 256.77 ft ft ft ft ft Insulation Area R =10.0 1386.00 ft R= ft R= ft 9. Wall Types a. Concrete Block - Int Insul, Exterior b. Concrete Block - Int Insul, Adjacent c. N/A d. N/A 10. Ceiling Types a. Under Attic (Vented) b. N/A c. N/A 11. Ducts a. Sup: Attic Ret: Attic AH: Interior Sup. R= 6, 277.2 ft 12. Cooling systems a. Central Unit 13. Heating systems a. Electric Strip Heat 14. Hot water systems a. Electric b. Conservation features None 15. Credits I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Address of New Home: Date: City /FL Zip: EnergyGauge® USA - FlaRes2008 • • • • • •• • • •••• • • •••• • • •• • • • • • • • Insulation Area R =5.0 1205.30 ft R =5.0 183.75 ft R= ft R= ft Insulation Area R =19.0 1386.00 ft R= ft R= ft Cap: 43.6 kBtu/hr SEER: 16 • Ctip:.? • ...COP: 1 • • • • • • •• • Cap!40 gallonC • • . •F 0.92 • • •• • • •• • • • • •• • • • • *Note: The home's estimated Energy Performance Index is only available through the EnergyGauge USA - FlaRes2008 computer program. This is not a Building Energy Rating. If your Index is below 100, your home may qualify for incentives if you obtain a Florida Energy Gauge Rating. Contact the Energy Gauge Hotline at (321) 638 -1492 or see the Energy Gauge web site at energygauge.com for information and a list of certified Raters. For information about Florida's Energy Efficiency Code for Building Construction, contact the Department of Community Affairs at (850) 487 -1824. * *Label required by Section 13- 104.4.5 of the Florida Building Code, Building, or Section B2.1.1 of Appendix G of the Florida Building Code, Residential, if not DEFAULT. Pstat • • • • • • • • ROOM NAME Area (ft Htg load (Btuh) Clg load (Btuh) Htg AVF (cfm) Clg AVF (cfm) Residence 1386 21799 37508 1599 1599 Entire House 1386 21799 37508 1599 1599 Other equip loads 158 118 Equip. @ 0.95 RSM 35707 Latent cooling 7885 Tl1TAI0 4'200 04 OG7 43592 4 =00 4 =00 Project Iiiformati• 14334 SW 106 Terrace, Miami, FL 33186 Phone: 305 - 4084025 Fax: 305 - 408 -4026 Email: fem3046@bellsouth.net D esign Inforrnatao Outside db ( °F) Inside db ( °F) Design TD ( °F) Daily range Inside humidity ( %) Moisture difference (gr /Ib) Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat Short Form Entire House Enrique Fernandez For: Annika Ashton and Eric Hernandez 113 NE 105 Street, Miami Shores, Fl 33138 Htg 50 70 20 Clg 90 75 15 L 50 56 Method Construction quality Fireplaces HEATING EQUIPMENT COOLING EQUIPMENT Make n/a Make Trade Trade Model n/a Cond Coil 100 EFF Efficiency 0 Btuh Sensible cooling 21945 Btuh Latent cooling 12 °F Total cooling 1599 cfm Actual air flow 0.073 cfm /Btuh Air flow factor 0.00 in H2O Static pressure Load sensible heat ratio Printout certified by ACCA to meet all requirements of Manual J 8th Ed. wroghtsoft Right -Suite Residential 6.0.02 RSR40612 Auck C:\My Documents\Wrightsoft HVAC\Annika and Eric Residence (Memo Const.).rrp Calc = MJ8 Oriente Infiltration Job: Date: May 26, 2010 By: Enrique Fe andez €0 Simplified Loose 0 .. .. • • • • ...• • • • • •. • • •. . • • • • •. • • • ER •. • • • • • • 0 B t.il? „• 0 Btt • • • • • 0 Btuh' •• .. • • ....15 cfm • •• 1.043 cf�n /Btuh • D.00 in.A20” • • '..' 0033 •.•• • • • • 2010 - May -27 11:30:52 Page 1 Component Btuh /ft Btuh % of Toad Walls 3.3 3355 15.3 Glazing 25.4 6110 27.8 Doors 9.4 192 0.9 Ceilings 1.0 1358 6.2 Floors 1.0 1434 6.5 Infiltration 3.1 3915 17.8 Ducts 5435 24.8 Piping 0 0.0 Humidification 0 0.0 Ventilation 158 0.7 Adjustments 0 Total 21957 100.0 Component Btuh /ft Btuh % of load Walls 2.4 2483 6.6 Glazing 40.2 9660 25.7 Doors 14.4 294 0.8 Ceilings 3.6 5039 13.4 Floors 0.8 1068 2.8 Infiltration 1.2 1521 4.0 Ducts 9093 24.2 Ventilation 118 0.3 Internal gains 8350 22.2 Blower 0 0.0 Adjustments 0 Total 37626 100.0 14334 SW 106 Terrace, Miami, FL 33186 Phone: 305 - 408 -4025 Fax: 305 -408 -4026 Email: fem3046 @bellsouth.net Pr,o`ect Information For: 1 !! esign ,Condition Location: Miami, Int'I AP, FL, US Elevation: 13 ft Latitude: 26 °N Outdoor: Daily range ( °F) Wet bulb ( °F) Wind speed (mph) Heating 50 Overall U -value = 0.161 Btuh /ft °F Data entries checked. Building Analysis Entire House Enrique Fernandez Annika Ashton and Eric Hernandez 113 NE 105 Street, Miami Shores, Fl 33138 15.0 Cooling 90 11 77 (L) 7.5 ' . WrlghtsDft Right -Suite Residential 6.0.02 RSR40612 ACCK C:\ My Documents \Wdghtsoft HVAC\Annika and Eric Residence (Mamo Const.).rrp Calc = MJ8 Oriente Indoor: Heating Indoor temperature ( °F) 70 Design TD ( °F) 20 Relative humidity ( %) 50 Moisture difference (gr /Ib) 11.9 Infiltration: Method Simplified Construction quality Loose Fireplaces 0 eaten • Flows Job: Date: May 26, 2010 By: Enrique Fernandez • • •. • • • • • ••• • • ilPrio • • • • • • • • • • • • • • .. • COOIin • • • • • • •• • • • • • . • •• • • • • • • • .. • • • • . • • • • • Cooling 75 15 50 55.7 • • .... • • 2010 - May -27 11:30:52 Page 1 • • • • 14334 SW 106 Terrace, Miami, FL 33186 Phone: 305-408-4025 Fax: 305-408 -4026 Email: fem3046@bellsouth.net Project Information Design Conditio Location: Miami, Int'I AP, FL, US Elevation: 13 ft Latitude: 26 °N Outdoor: Dry bulb ( °F) Daily range ( °F) Wet bulb ( °F) Wind speed (mph) Construction descriptions Walls 51G: Block Wall 51 F: Adjacent to Unconditioned Space Partitions (none) For: Component Constructions Entire House Enrique Fernandez Annika Ashton and Eric Hernandez 113 NE 105 Street, Miami Shores, Fl 33138 Heating 50 15.0 Cooling 90 11 (L ) 77 7.5 Windows 1A -c1om: Operable, metal frame, no break, clear glass, 1 pane; 2 ft overhang n e s w nw all 1A -c1 omd: Sliding glass door, metal frame, no break, clear glass, n 1 pane Indoor: Heating Indoor temperature ( °F) 70 Design TD ( °F) 20 Relative humidity ( %) 50 Moisture difference (gr/Ib) 11.9 Infiltration: Method Simplified Construction quality Loose Fireplaces 0 Or Area U -value insul R Htg HTM Loss C011111. Gain (ft') (Btuh/ft' -- °F) (ft? °F/Btuh) (BtuhIt'4 •(Btuh) ('W 1 (Btuh)IP • • • •• • n 204 0.200 5.0 4.06. • • • 818 e 242 0.200 5.0 4.04 • •:•867 s 228 0.200 5.0 4.00•••• 913 w 133 0.200 5.0 4.06••••%31 nw 32 0.200 5.0 4.0Q.•••.127 all 839 0.200 5.0 4.0Q,'.3355 s 90 0.000 0.0 0.0Q 0 w 94 0.000 0.0 0.0Q • ; 0 all 184 0.000 0.0 0.0Q • 0 • • • •• • •.•• 69 36 62 7 26 200 41 1.270 0.0 1.270 0.0 1.270 0.0 1.270 0.0 1.270 0.0 1.270 0.0 1.270 0.0 Doors 11A0: Wood door, hollow core, no storm s 20 0.470 0.0 Ceilings 16A -19ad: Ceiling under unvented attic, no radiant barrier, dark 1386 0.049 19.0 shingles, R -19 insul. Floors 19A -11 cswp: Hardwood floor over tight enclosed crawl, No wall 1386 0.073 11.0 insul, R -11 blanket wngh'tsoft Right -Suite Residential 6.0.02 RSR40612 C:\My Documents \Wrightsoft HVAC1Annika and Eric Residence (Memo Const.).rrp Calc = MJ8 Orienta 25.4 25.4 25.4 25.4 25.4 25.4 25.4 Job: Date: May 26, 2010 By: Enrique Fernandez 1753 914 1584 168 654 5073 1036 Cooling 75 15 50 55.7 • ••• X 296 • 6050 2.96 715• •296 • 6768 :2.g6.• 393••••• 2.516 • 94••i•• '42e, 2483 0.04 0 ,0.00. 0 0, . • • •. 34.6 44.2 34.6 44.2 70.3 41.3 34.6 2391 1592 2161 292 1810 8247 1414 9.40 192 14.4 294 0.98 1358 3.64 5039 1.03 1434 0.77 1068 2010 -May- 2711:30:53 Page 1 • • • � • • • • 4 - S •••• • • • • •••• • • • • •• • • ••• • • • • • •• • • •• •• •• • • • • • • • • • • •• •• • • • • • • •• • •• • • • • • • • • • • • • • • • • • • • • •• • •••• • • • • Wnghtsoft Right -Suite Residential 6.0.02 RSR40612 2010-May-27 11:30:53 AGIO{ C:\My Documents\Wrightsoft HVAC\Annika and Eric Residence (Memo Const.).rrp Cale = MJ8 Oriente Page 2 • • • •• Project Summary Entire House Enrique Fernandez 14334 SW 106 Terrace, Miami, FL 33186 Phone: 305 - 408 -4025 Fax: 305 - 408 -4026 Email: fem3046@bellsouth.net 1"o1ec I nforrmation • Design Inforinationvt Outside db Inside db Design TD Notes: Structure Ducts Central vent (7 cfm) Humidification Piping Equipment load Method Construction quality Fireplaces For: Annika Ashton and Eric Hernandez 113 NE 105 Street, Miami Shores, Fl 33138 Heating Summary Infiltration Weather: Winter Design Conditions 16364 Btuh 5435 cfm 158 Btuh 0 Btuh 0 Btuh 21957 Btuh Simplified Loose 0 Heating Cooling Area (ft 1386 1386 Volume (ft 11365 11365 Air changes /hour 0.94 0.49 Equiv. AVF (cfm) 178 93 Heating Equipment Summary Make n/a Trade Model n/a Efficiency 100 EFF Heating input 0 Btuh Heating output 21945 Btuh Temperature rise 12 °F Actual air flow 1599 cfm Air flow factor 0.073 cfm /Btuh Static pressure 0.00 in H2O Space thermostat Miami, Int'I AP, FL, US Summer Design Conditions 50 °F Outside db 70 °F Inside db 20 °F Design TD Daily range Relative humidity Moisture difference • Sensible Cooling Equip Structure • . • ;2$415 Btuli Ducts 9093 uh Central vent (7 cfm) • .118 Eit h • i tu Blower ••" 0 h Use manufacturer's data Rate /swing multiplier Equipment sensible Toad •• • Latent Cooling Equipni Structure Ducts Central vent (7 cfm) Equipment latent load Equipment total load Req. total capacity at 0.70 SHR Cooling Equipment Summary Make Trade Cond Coil Efficiency Sensible cooling Latent cooling Total cooling Actual air flow Air flow factor Static pressure Load sensible heat ratio Printout certified by ACCA to meet all requirements of Manual J 8th Ed. . WrIg' htsoft Right -Suite Residential 6.0.02 RSR40612 i(� C\ C:\My Documents \Wrightsoft HVAAnnika and Eric Residence (Memo Const.).rrp Calc = MJ8 Oriente Job: Date: May 26, 2010 By: Enrique Fernandez 90 °F 75 °F 15 °F L 50 % fb 56 �P /• • •••• • teen$ Loas1•S$zing • • • • • •• •• n • •• • • ••1195 • • • 35707 1:314,11 • • • exit Load 4513 Btuh 3100 Btuh 272 Btuh 7885 Btuh 43592 Btuh 4.3 ton 13 SEER 0 Btuh 0 Btuh 0 Btuh 1599 cfm 0.043 cfm/Btuh 0.00 in H2O 0.83 2010 - May -27 11:30:53 Page 1 • • • • • • • • • • • • • • 14334 SW 106 Terrace, Miami, FL 33186 Phone: 305 - 408 -4025 Fax: 305 - 408 -4026 Email: fem3046 @bellsouth.net Project lnforrnation 14,000— 12,000- 10,000 8,000 — 6,000 — 4,000 - 2,000— 0 For: Location: Miami, Int'I AP, FL, US Elevation: 13 ft Latitude: 26 °N Outdoor: Dry bulb ( °F) Daily range ( ° F) Wet bulb ( °F) Wind speed (mph) 8 9 AED Assessment Entire House Enrique Fernandez / Hourly Annika Ashton and Eric Hernandez 113 NE 105 Street, Miami Shores, Fl 33138 Design Conditions Heating 50 15.0 Cooling 90 11 (L ) 77 7.5 st for r Adequate Exposure Divers! Hourly Glazing Load 10 11 12 13 14 15 Hour of Day ® Average . vvr iglhtsoft Right -Suite Residential 6.0.02 RSR40612 ACok C:\My Documents \Wrightsoft HVAC1Annika and Eric Residence (Memo Const.).rrp Calc = MJ8 Oriente Indoor: Heating Indoor temperature ( °F) 70 Design TD ( °F) 20 Relative humidity ( %) 50 Moisture difference (gr/Ib) 11.9 Infiltration: Method Simplified Construction quality Loose Fireplaces 0 16 17 18 19 20 / AEDOmtt Maximum hourly glazing Toad exceeds average by 25.0 %. House has adequate exposure diversity (AED), based on AED limit of 30 %. AED excursion: 0 Btuh Job: Date: May 26, 2010 By: Enrique Fernandez Cooling 75 15 50 55.7 •••• • • • • •••• • • •• • • ••• • • • •• • • • • •• • • • a • • •••• • •• •• • • • • • • • •• •• • • • • • • • • •• • •••• • •••• 2010 - May -27 11:30:53 Page 1 • • • • • • • • • • • • • • • • Right -J Worksheet Entire House Enrique Fernandez 14334 SW 106 Terrace, Miami, FL 33186 Phone: 305 - 408 -4025 Fax: 305 - 408 -4026 Email: fem3046@bellsouth.net Printout certified by ACCA to meet all requirements of Manual J 8th Ed. vv toht50'ft Right -Suite Residential 6.0.02 RSR40612 C:1My ocuments\Wrightsoft HVAC'Annika and Eric Residence (Mamo Const.).rrp Calc = MJ8 Oriente Job: Date: May 26, 2010 By: Enrique Fernandez 1 2 3 4 5 6 11 6 12 13 14 15 Room name Exposed wall Ceiling height Room dimensions Room area Ty Construction U -value number (Btuh/ft - °F) G . 0.200 1A -clom 1.270 1A -clomd 1.2'70 51G 0.200 1A -c1 om 1.270 51G 0.200 1A -clam 1.270 11A0 0.470' 51F 0.000 51G 0.200 1A -dlom 1.270 51F 0.000 51G 0.200 1A -clout 11,270 16A -19ad 0.049 19A- 1lcswp 0.073 Or e e s HTM (Btuh/ft Heat 4.00 26.40 25.40 4.00 25.40 4.00 25.40 9.40 0.00 4.001 25.40 0.00 4.00 25.40 0.98 1.03 Coo 2.96 90.99 2.96 37.75 14.43 0.00 2.96 9 0.00 2.96 70.30 0.77 c) AED excursion Envelope Toss /gain a) Infiltration b) Room ventilation Internal gains: Less external load Less transfer Redistribution Subtotal Duct Toads Occupants © 230 Appliances @ 1200 Total room load Air required (cfm) 8.2 ft 1386.0 ft Entire House 0.0 ft Area ft or perimeter (ft) Gross 41 278 36 311 62 20 90 7 94 57 26 1386 1386 5 6 33% N/P /S 04 0 0 242 30 228 6,2 2tl 90 193 94 32 0 1386 0 32% Load (Btuh) Heat 918 1753 1036 967 914 913 1584 1 92 0 531 168, 0 127 654 1358 1434 12449 3915 0 0 0 0 16364 5435 21799 1599 Cool 605 1414 715 1592 676 2161 294 0 393 29 2 0 94 1810 5039 1068 0 18545 1521 0 1150 7200 0 0 0 28415 9093 37508 1599 Residence 0.0 ft 8.2 ft heat/cool 46.2 x 30.0 ft 1386.0 ft Area ft or perimeter (ft) Gross N/P /S 314 69 41 278 36 311 62 20 90 139 7 94 57 26 '. 1386 1386 4 0 0 242 30 228 82' 20 90 94 32' 1386 0 • • • • •• ; • a •••••• 1010.• 0010• •10••10• • ", " • • • • 1• • 5 6 33% 32% Load (Btuh) Heat 967 914 913 1584 192 1358 1434' ••• r • • • " • _ .. • *Stilt • Al • •• • • 12449 3915 0 0 0 0 16364 5435 21799 1599 Cool 605 391 1414 715 1592 678 2161. :294• 0 393 292 94' 10 5039 1068 • • • • • • •• • • • 0 18545 1521 0 1150 7200 0 0 0 28415 9093 37508 1599 1 • 1 1 1 1 1 • 2010 - May -27 11:30:53 Paae 1 • • • ••••• • • • • • •••• • • •••• • •