Loading...
BP2004-425MIAMI SHORES VILLAGE ( 0 ) BUILDING DEPARTMENT 305- 795 -2204 Building Inspection Request Phone # Date Type Insp'n Permit No RP Name Address q o .r. lo / J Company Inspection Date \() 4 /0 Approved Correction Re -Insp' n Fee Permit Type (c Owner's Name (Fee Simple Title o . er le ): Building Owner's Address 3k Tenant/Lessee Name Job Address (where the work is being done) ',� City Miami Shores Village County Is Building Historically Designated YES NO $ Value of Work For this Permit \\ .Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 BUILDING f PERMIT APPLICATIJ14 Z FBC 2001 Master Permit No. Electrical Plumbing Mechanical Roofing \\ N , (1 \ _�1 \ \c . `, Phone ) ) � r 1 - City \,, - ,--N State '� 1 Zip fit' \? ` Miami -Dade Zip _. 1 c) Phone # Permit No. (1 •e 7COLI ' L i 25 Contractor's Company Name \$`,1 ► _ _ _ Phone # Contractor's ldress 1 - ` .1�� Yl �- 2_1 ''\'r: City kl State`' ' Zip Qualifier Architect/Engineer's Name (if applicable) Phone # Square Footage Of Work: Type of Work: ❑Addition ❑Alteration ❑New Repair /Replace ❑ Demolition Describe Work: C - rr J V Ot1 / r Submittal Fee $ hC ( Permit Fee $ ret/ " CCF $ t 0 CO /CC Notary $ Training/Education Fee $ C.! r " 0 Technology Fee $ . i 7) Total Fee Now Due $ 5 . / D (Continued on opposite side) * * * * * * * * * * * * * * * * * * * * * * * * * * ** F ees * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Scanning $ 6 Radon $ Zoning Bond $ Code Enforcement $ Structural Plan Review. $ Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Sign �� -; 4 _ •,\ L \ Signature Owner or Agent Contractor The foregoing instrument was acknowled _ed before me this The foregoing instrument was acknowledged before me this day of ircap ,200-1, by , j: � .� , " day of _ , 20 —, by who is .er onally known to me or who has produced I who is personally known to me or who has produced NOTARY Sign: Print: My Commission Expires: Chc 12/15/03 As identification and who did take an oath. as identification and who did take an oath. = NOTARY PUBLIC: sion .fib m3 Sign: Print: My Commission Expires: (Certificate of Competency Holder) State Certificate or Registration No. Certificate of Competency No. ********************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** .V *� *tt *Z884 * * * * * * * * * * * * * * * * * ** 1 APPLICATION APPROVED BY: Plans Examiner Engineer Zoning Signed: (INSPECTOR) Miami Shores Village 10050 NE 2nd Avenue Phone: 305- 795 -2204 Permit Number: BP2004 -425 Printed: 3/30/2004 Applicant: ALLAN Owner: KELLEY JOB ADDRESS: 720 NE 101 ST Contractor Local Phone: Parcel # 1132060172210 Building Permit KELLEY ALLAN Contractor's Address: Permit Status: APPROVED Permit Expiration: 9/25/2004 Construction Value: $1,700.00 Work: GARAGE DOOR Page 1 of 1 Legal Description: AMD PL MIAMI SHORES SEC 4 LOTS 5 & 6 & W10FT LOT 4 BLK 104 PB Fees: Description Amount FEE2004 -3343 Building Fee $100.00 FEE2004 -3344 CCF $1.20 FEE2004 -3345 Notary Fee $5.00 FEE2004 -3346 Training and Education Fee $0.40 FEE2004 -3347 Technology Fee $2.50 FEE2004 -3348 Scanning Fee $6.00 Total Fees: $115.10 Total Fees: $115.1, Total Receipts: $0 00 6 . . 1 In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responisibility for all work done by either myself, my agent, servants or employes. Signed: (Contractor or Builder) BY: Located at: C) `C1 \ `M\ K \ r Yb g By Produced OWNER BUILDER DISCLOSURE STATEMENT 1 - 1 1 )-eke - 7_,eQ . VILLAGE OF MIAMI SHORES BUILDING DEPARTMENT being the legal property owner, for the property Legally described as Do hereby petition the Village of Miami Shores to act as my own contractor pursuant to the laws of the State of Florida, F.S. 489.103(7),And I have read and understand the following disclosure Statement, which entitles me td 3Irork as my own contractor, I further understand that I as the owner must appear in person to complete all applications. DISCLOSURE STATEMENT State law requires construction to be done by licensed contractors. You have applied for a permit under an exemption to that law. The exemption allows you, as the owner of your property, to act as your own contractor even though you do not have a license. You must supervise the constT uction yourself. You may build or improve a one - family or two-family residence or a farm out - building. You may also build or improve a commercial building at a cost of $25,000.00 or less. The building must be for your own use and occupancy. It may not be built for sale or lease. If you sell or lease a building you have built yourself within one year after the construction is completed, the law will presume that you built it for sale or lease, which is a violation of this exemption. You may not hire an unlicensed person as your contractor. It is your responsibility to make sure that people employed by you have licenses required by state law and by county or municipal licensing ordinances. Any person working on your building who is not Iicensed must work under your supervision and must be employed by you, which means that you must deduct F.I.C.A. and with- holding tax and provide workers' compensation for that employee, all as prescribed by law. Your construction must comply with all applicable laws, ordinances, building codes and zoning regulations. initial of reviewing clerk. Tile foregoing instrument Proof of ownership provided ( ) Was aclgtowledged before me this 2q da of rrOMO_(IL . r `Iho i s personally known to me or who has as identification and who did take an oath.. mis5 or.0:231c13 ° ^ 3Cr 12es: n i 203i --;1, �O7 �pe�� Lond?•dl Thru Atlantic Bondin;; Co., • BUILDING CODE COMPLIANCE OFFICE (BCCO) PRODUCT CONTROL DIVISION NOTICE OF ACCEPTANCE (NOA) DAB Doors Inc. 12195 N.W. 98 Avenue Hialeah Gardens, FL 33018 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by Miami -Dade County Product Control Division and accepted by the Board of Rules and Appeals (BORA) to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right to revoke this acceptance, if it is determined by Miami - Dade County Product Control Division that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Sectional Garage Door16'- 2" Wide. APPROVAL DOCUMENT: Drawing No. 01 -19, titled "Sectional Residential Garage Door ", dated 04/06/01 with last revision on 08/30/01, sheets 1 through 3 of 3, prepared by Al- Farooq Corporation, signed and sealed by H. Farooq, P.E., bearing the Miami -Dade County Product Control Renewal stamp with the Notice of Acceptance number and expiration date by the Miami -Dade County Product Control Division. MISSILE IMPACT RATING: Large and Small Missile Impact LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product. for sales. advertising or any other purposes shall automatically terminate this NOA...Failure to comply with any section of this NOA shall be cause for tennination and removal of NOA. LIMITATION: This approval requires the manufacturer to do testing of all coils used to fabricate door panels under this Notice of Acceptance. A minimum of 2 specimens shall be cut from each coil and tensile tested according to ASTM E -8 by a Dade County approved laboratory selected and paid by the manufacturer. Every 3 months, four times a year, the manufacturer shall mail to this office: a copy of the tested reports with confirmation that the specimen were selected from coils at the manufacturer production facilities. And a notarized statement from the manufacturer that only coils with yield strength of 39,000 psi or more shall be used to make door panels for Dade County under this Notice of Acceptance ADVERTISEMENT: The NOA number preceded *by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA # 01 -0626.01 consists of this page 1 as well as the approval document mentioned above. The submitted documentation was reviewed -h' (and F. For PE. _J MIAMI -DADE COUNTY, FLORIDA METRO -DADE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 MIAMI, FLORIDA 33130 -1563 (305) 375 -2901 FAX (305) 375 -2908 NOA do 03- 0402.01 Expiration Date: October 04, 2006 Approval Date: April 24, 2003 Page 1 'DOOR IiEIGHT CONSISTS OF 6' -6" 2 SECTIONS 18" 2 SECTIONS 21" 6' -9" 1 SECTION 18" 3 SECTIONS 21' T 4 SECTIONS 21' — T -3' — — 1-6" 5 SECTIONS 18' - 7' -9' 4 SECTIONS 18" 1 SECTION 21" 8' 3 SECTIONS 18" 2 SECTIONS 21' 8' -3" 2 SECTIONS 18" 3 SECTIONS 21' 8' -6" 1 SECTION 18' 4 SECTIONS 21" 8' -9" 5 SECTIONS 21' — 9' 6 SECTIONS 18" — 9' -3" 5 SECTIONS 18" 1 SECTION 21" 9' -6' 4 SECTIONS 18" 2 SECTIONS 21" 9' -9" 3 SECTIONS 18' 3 SECTIONS 21" 10' 2 SECTIONS 18" 4 SECTIONS 21" 10 " -3" 1 SECTION 18" 5 SECTIONS 21" 10 " -6" 6 SECTIONS 21' — 10' -9" 6 SECTIONS 16 1 SECTION 21' 11' 5 SECTIONS 18" 2 SECTIONS 21' 11' -3" 4 SECTIONS 18" 3 SECTIONS 21" 11' -6" 3 SECTIONS 18' 4 SECTIONS 21" 11' -9" 2 SECTIONS 18" 5 SECTIONS 21' 12' 1 SECTIONS 18' 6 SECTIONS 21' 12' -3' 7 SECTIONS 21' — 12' -6" 6 SECTIONS 18" 2 SECTIONS 21' 12' -9' 5 SECTIONS 18' 3 SECTIONS 21" 13' 4 SECTIONS 18" 4 SECTIONS 21" 13' -3" 3 SECTIONS 18" 5 SECTIONS 21" 13' -6' 2 SECTIONS 18' 6 SECTIONS 21' 13' -9' 1 SECTION 18' 7 SECTIONS 21" 14' 8 SECTIONS 21' — 14' -3" 6 SECTIONS 18" 3 SECTIONS 21" 14' -6" 5 SECTIONS 18" 4 SECTIONS 21" 14' -9" 4 SECTIONS 18" 5 SECTIONS 21" 15' 13 SECTIONS 18" 6 SECTIONS 21" 15' -3" 2 SECTIONS 18' 7 SECTIONS 21' 15' -6" 1 SECTION 18' 8 SECTIONS 21" 15' -9" 9 SECTIONS 21" — 16' 6 SECTIONS 18' 4 SECTIONS 21" CENTER STILES CONFIGURATION DOOR WIDTHS j OF CENTER STILES 8' -0" TO 9' -0" 2 9' -1" TO 11' -10" 2 11-0" TO 13' -10" 3 14' -0" TO 15' -10' 4 15-11" TO 16' -2" 5 CENTER STI SEE SCH. 1 10101 MAX. DOOR WIDTH 16' -2" 7 -1/2" X .071" GALV. STEEL END ROLLER HINGE W/ (6) # 14 X 5/8" SMS 7- X .050' GALV. STEEL CE R HINGE W/ (4) j 14 X 1/2" SMS LOCK 2/ DOOR 3/4" W X .15 THK. LATCH SPRING LOADED SLIDE BOLT LOCK (BOTH SIDES) FASTENED W/ (4) # 14 X 1/2' S.M.S. 5/8" MIN. LOCK ENGAGEMENT CONFORMS TO SFBC 3603.2 REGARDING GARAGE DOORS 7 X 7 GALV. AIRCRAFT TYPE CABLE & NICO —PRESS SLEEVE W/ MIN. 5 TO 1 SAFETY FACTOR CENTER STILE OUTSIDE HANDLE 7 "X3'X 0.1 STEEL PLATE WITH (4) #14 X 3/4" • SELF DRILLING SCREWS END STILE OUTSIDE KEYED _LOCK LOCK BAR LOCKING SHOWN I► 8' -0" TO 9' -0" DOOR WIDTHS DOOR WIDTHS 12' -0' TO 13' -10" DOOR WIDTHS PUSH NUT CENTER STILES ■ LOCK BAR GUIDES INSTALLED ON END STILE WITH (4) #14 X 5/8" SMS .16T X .6W LOCK BAR ENGAGES IN TRACK ON EACH SIDE OF DOOR SCHEDULE 'A' TOP FIXTURE 5 -1/2' X 2 -3/4" X 0.1' - STEEL PLATE WITH (6) #14 X 3/4" SELF DR'LLNG SCREWS OPTIONAL VENT MAXIMUM OPENING AREA 120 SQ. IN. - -— 14' -0" TO 15' -1O" DOOR WIDTHS 1 DOOR WIDI i5 15' —'1" TO 1F' -2' INSIDE ELEVATION RAISED PANEL EMBOSSED DOOR OPTIONAL FLUSH FACE WOOD GRAIN DESIGN LEA 1- x (.0 w 0 0 0 0 m 0 0 0 N z 0 0 w v) (-5 0 W 0 0 x V) z 0 O 0 0 w (f) 1 Z io DAB DOOR MODEL 824 MAX. SIZE 16' -2" WIDE X 16' -0" HIGH DESIGN PRESSURE RATING = + 48.0 PSF — 52.0 PSF GENERAL NOTES 1. THIS STRUCTURE IS DESIGNED AS PER THE SOUTH FLORIDA BUILDING CODE 1994 EDITION FOR DADE COUNTY. ALSO FOR WIND LOADS AS PER ASCE 7 -88 USING CORRESPONDING LOADS. 2. ANCHORS SHALL BE AS LISTED, SPACED AS SHOWN ON DETAILS. ANCHOR EMBEDMENT TO BASE MATERIAL SHALL BE BEYOND WALL DRESSING OR STUCCO. 3. ALL BOLTS. NUTS AND WASHERS SHALL BE ZINC PLATED CARBON STEEL 4, ANCHORING OR LOADING CONDITIONS OTHER THAN THOSE SHOWN IN THESE DETAILS ARE NOT PART OF THIS APPROVAL Engr. DR. HUMAYOUN FAROOQ STRUCTURES FLA. PE # 16557 s* i • APr) :i<<<o CU sr'ulaU L °.1 :,1 7iit SHIN FLORIDA, BU/ CODE GATE (ICI ..� BY ' 'RODUC1 CO DIVISION BUILDING CODE COMPLIANCE OFFICE cc:F;k +CE H0.0 / O626.6L, t Jc, z — co 0 zW I CD 0 <I 1""1 N • 0 a o M O a a 0v) U L o z w n o n c70 O 0 C1-- X vi 0 C .i, w 1 K M C ) 0 0 0 W 0_ 0 J 1— z w 0 U) W J z 0 1--- 0 W 0 y 0 0. U T) v .0 a1 0 0 0 w 0 U 0 cc m O 0 o 0 a 8 - ( drawing ro. 01 -19 (sheet 1 of 3 j 0 CO 0 0 1 7 0 -j L.1 4- r 16 GA. X 2 -1/4" X 2" GALV. STEEL U.BAR REINFORCING TRUSS 0 TOP OF PAJ:Q. TRUSS FASTENED TO VERTICAL INTERMEDIATE STILES w/ TWO # 14 X 5/8" S.M.S. AND TO END S11LE W/ FOUR 14 X 3/4' SELF DRILUNG S. 055" X 2 -1/4" X 2" GALV. STEEL U.BAR REINFORCING TRUSS 0 BOTTOM OF PANEL TRUSS FASILNED TO VERTICAL INTERMEDIATE STILES W/ TWO #14 X 5/8" S.M.S. AND TO END STILE W/ FOUR if 14 X 3/4" SELF DRILLING S. 1ST SECTION (BOTTOM) REINFORCING SOUTHERN PINE 0.55 S.G. BOTTOM SEAL .058 ALUM PLATE WITH 1/8' X 1" S.M.S. 0 48' 0.C. AND RUBBER WEATHERSTRIPPING OPTIONAL STOP MOULDING BY DOOR INSTALLE STEEL TRACK BRACKET FASTENED TO WOOD JAMB WITH 5/16" X 1 -3/4' LAG SCREW HEX WASHER HEAD TYPE A 1 -1/4" 1 1.9" X 2.19" X 3.3" X .090" STEEL TRACK BRACKETS SEE SHEET 2 FOR SPACING 2 -1/8" X 1" X .078" GALV. STEEL TRACK FASTENED TO TRACK PLATES W/ t 4 -20 X 5/8" TRUSS HD. SLOT 17._ & V 1,- . j 1 1/2" X 1 -3/4" X 16 GA. (O.0•o8 ") OPEN TUBE 0 TOP & BOTTOM OF EACH PANEL _ # X 5/8" SMS 6 PER HINGE 7 / • ':' iNs7ALLED GN k1LLER SHAD INTERMEDIATE SECTIONS REINFORCING 7 -1/2" X.050 GALV. STEEL CENTER HINGE 16 GA.X 2 -1/4' X 2" GALV. STEEL U.BAR REINFORCING TRUSS TRUSS FASTENED TO VERTICAL INTERMEDIATE STILES W/ TWO 14 X 5/8" S.M.S. AND TO END STILE W/ FOUR # 14 X 3/4" SELF DRILLING SCR. 1/2" X 1 -3/4' X .058" FORMED STEEL -GLUED TO PANEL AND SECURED TO END STILE WITH 3/16" POP RIVETS 0 12" 0.C. 1 -7/8" X 2 -5/8" X .049' STEEL CENTER STILE, GLUED AND RIVETED TO PANEL W/ (4) 3/16" RIVETS # 14 X 5/8" S.M.S. 4/ HINGE L INTERIOR SIDE SECTION E -E POP RIVETS 7 -1/2" X .071 "J END ROLLER HINGE TOP SECTION REINFORCING DGE 3/4" X 2" X 2 -1/2" X .049" STEEL END STILE, CONNECT TO PANELS WITH FLAPS AND (4) 3/16" ALUM RIVETS SEE DETAIL ABOVE 3 -3/4" MIN. DISTANCE • e p e 1.82" 1. X .50 P:JLL W/ .44 DiA. X 4 -1/4" STEM 16 GAX 2 -1/4" X 2" GALV. STEEL U.BAR REINFORCING TRUSS TRUSS FASTENED TO VERTICAL INTERMEDIATE STILES W/ TWO # 14 X 5/8" S.M.S. AND TO END STILE W/ FOUR # 14 X 3/4" SELS DRILLING SCR. e H1-1 /8 "h- '/4 -20 SS BOLT & itv. FLAPS BENT OVER PANEL 1/2" PUNCHED HOLES 0 4" 0.C. 1/2" HILTI SLEEVE ANCHORS OR EQUAL 1 -1/2" MIN. EMBED INTO MASONRY 1 PER BRACKET Engn DR. HUMAYOUN FAR000 STRUCTURES FLA. PE # 16557 24 GA. STEEL PANEL -- 0 0 0 -END STILE 7 63- o4v_2I jQDD FPTr.lVED AS Ci SOUTH FLORID& BUI1UIid COOL WE OCT � � 9 'i Cr by CON .`.. DIVISION RUliOW; CODE. COIiPIIE.NCF OFFICE 1CCHif. tF. � �:�_ ( O O w J 1- z w 0 (1) w J z O 1- U w U) l ( ) rn c 0 N . 0 0. U to 0 .o 0 v 0 ( ) 0 CO 0 0 0 CD 0 0 I 4 CO N r T 0 .0 J L L drawing no. ) 01 -19 (sheet 2 of 3 ,1 DOOR HEIGHT • SECTION HEIGHTS BRACKET PLACEMENTS 1ST 2ND 3RD 4TH 5TH B1 B2 B3 B4 B5 .86 B7 B8 6' -0" 18" 18" 18" 18" N/A 1" 11 -3/4" 23" 34" 45" 56" 67" - 6'- 6" 21" 18" 18" 21" N/A 1" 11 -3/4" 23" 34" 45" 56" 67" - 7' -0" 21" 21" 21" 21" N/A 1" 11 -3/4" 23" 34" 45" 56" 67" 78-1/4" 7' -6" 18" 18" 18" 18" 18" 1" 11 -3/4" 23" 34" 45" 56" 67" 78 -1/4" 8' -0" 21" 18" 18" 18" 21" 1" 11 -3/4" 23" 34" 45" 56" 67" 78 - 1/4" HIL11 SLEEVE ANCHOR SPACING ANCHOR STRUCTURE EMBED SPACING 5/16 BLOCK 1 -1/4" 6 CONC. 1" 6 3/6 BLOCK 1 -1/4" 8 CONC. 1 -1/4" 9 f J 2" SECTION A - A SEE SHEET 2 FOR LOCATION OF REINFORCING TRUSSES 14 G& GALV. STEEL ADJUSTABLE SLIDE FASTENED TOO BRACKET M/ IS CREWS? 3/4" & NUTS." HEX HEAD HORIZONTAL REINFORCEMENT 1/2" X 1 -3/4" X .058" FORMED STEEL GLUED TO PANEL AND FASTENED TO VERTICAL STILES WITH (2) 3/16" POP RIVETS 2 -3/4" X 5 -1/2" X 3" X .104" GALV. STEEL TOP ROLLER BRACKET (DOUBLE) FASTENED W/ (6) # 14 X 5/8" S.M.S. HORIZONTAL REINFORCEMENT 1/2" X 1 -3/4" X .058" FORMED STEEL GLUED TO PANEL AND FASTENED TO VERTICAL STILES WITH (2) 3/16" POP RIVETS 5/16" MEETING RIB 1.82" DIA. X .50" ROLLERS W/ .44 DIA. X 4-1/4" STEM QPTIONAL INSULATIONS BY 'APACHE PRODUCTS CO' EPS- EXPANDED POLYSTYRENE DENSITY = 1.07 PCF N.OA # 98- 0904.04 OR ISO -25 POLY - ISOCYANURATE DENSITY = 2.0 PCF N.OA # 98- 0904.03 14 GA. GALV. STEEL ROLLER HINGES FASTENED w/ (6) # 14 X 5/8" SMS MIN. .024" ROLL FORMED STEEL PANEL DRAWING QUALRY G -40 MIN. YIELD STRENGTH = 39 KSI WITH PRIMER AND BAKED -ON POLYSTER PAINTED TOP COAT APPUED TO BOTH SIDES OF STEEL 1 12 GA. GALV. STEEL BOTTOM BRACKET FASTENED W/ (4) # 14 X 5//8" SMS re 5/16" X 1 -5/8" LAG SCREWS INTO WOOD OR 5/16" SLEEVE ANCHORS WITH 1 - 1/4" EMBED INTO MASONRY 3 PER BRACKET 2 -1/2" X 4 -1/4" X 13 GA. STEEL PLATES WELDED TO 1 -1/2" X 1 - 1/2" X 14 GA. ANGLE FASTENED TO TRACK WITH (4) 1/4 -20 SS. BOLT & NUTS L7) z Z w 0 n N m1 TRACK CONFIGURATKE CAST ALUM. „,_---- DRUM WOOD FRAMLBUILDINGS STUD WALLS OR COOR OPENING SHALL BE FRAMED SOUD BY NOT LESS THAN (3) 2X6 PRESSURE TREATED GRADE 2 OR BETTER WOOD STUDS. STUD WALLS TO EE CONT. FROM FOOTING TO TIE BEAM. WOOD BUCK CONNECTION TO MASONRY TRACK SHALL BE SECURED WITH TRACK BRACKETS TO PRESSURE TREATED 2X6 W000 JAMBS WHICH SHALL BE ANCHORED TO GROUTED REINFORCED MASONRY BLOCK WALL OR CONC. COLUMN W/ 1/4" TAPCONS WITH 1 - 3/4" EMBED AND A SPACING OF 8" 0.C. OR 3/8" DIA. HII.TI SLEEVE ANCHORS, 1 -3/4" MIN. EMBED AND A SPACING OF 12" O.C. THE BLOCK WALL CELLS SHALL BE GROUT FILLED AND REINFORCED WITH FOUR {j 5 BARS EXTENDING INTO FOOTING AND INTO TIE BE +MS, ALL BARS SHALL BE CONTINUOUS FRCM TIE SEAMS TO FOOTING. PREPARATION OF JAMBS BY OTHERS HORIZ. TRACK SUPPORT AS READ. BY DOOR INSTALLER HORIZ. TRACK LENGTH = OPENING HEIGHT PLUS 12" •- SECTIONS ARE NUMBERED STARTING AT THE BOTTOM FOR DOORS MORE THAN 8 FT. HIGH, USE ADDITIONAL TOP BRACKETS AT 10" 0.C. 14 GA. GALV. STEEL TRACK y ---- -� 2" X 3 -1/2" X 12 GA. TRACK BRACKETS 2 -3/16" HIGH CONNECTED TO TRACK WITH ONE 1/4" BOLTS & NUTS. 1 -1/2" STEEL STRUCTURE BY OTHERS MUST SUPPORT THE LOADS IMPOSED BY DOOR SYSTEM 1/4" 0 HEX HEAD M.S. & LOCK NUT 0 12" 0.C. ALTERNATE TRACK INSTALLATION 3" X 2" X 14 GA CONT. STEEL ANGLE 2" X 3" X .102" STEEL FLAT BRACKETS 0 ±12" 0.C. CONNECTED TO CONT. ANGLE W/ (3) 1/4" 0 SPOT WELDS i J4 MIN. EDGE DISTANCE 1-3 3/4" TYPICAL Engr. DR. HUMAYOUN FAR000 STRUCTURES FI A. PE # 16557 CONC.= MIN. 3000 PSI 1 -1/2" I•.- 1/4 -20 SS BOLT & NUT AT 12" 0.C. 2 -1/8" X 1" X .078" GALV. STEEL TRACK FASTENED TO TRACK PLATES W/ (2) 1/4- 20X5/8" TRUSS HD. SLOTTED M.S. & LOCK NUT LPPrOVED LS COMPLYIEB WITH THE SOUTH FLORID', BUIL4I +WODE DATE ICI 0 JU1 BY PRODUCT CO L DIVISION BUILDIN( CODE COMPLIANCE OFFICE E4CCFY ANCE !.t). Q/ —C 26.G/ co O W � Q J L_ U z Z co o CS O z CO J ( in c 0 t_ c 0 0. N a0 0 .0 0 0 0 0 0 0 d m 0 0 w x ) drawing no.1 01 —19 (sheet 3 of 3