Loading...
514 NE 101 St (3)MIAMI SHORES VILLAGE APPLICATION FOR BUILDING PERMIT Application is hereby made for the approval of the detailed statement of the plans and specifications herewith submitted for the build- ing or other structure herein described, This application is made in compliance and conformity with the Building Ordinance of Miami Shores Village, Florida, and all provisions of the Laws of the State of Florida, all ordinances of Miami Shores Village and all rules and regulations of the Building Division of Miami Shores Village shall be complied with, whether herein specified or not. A copy of approved plans and specifications must be kept at building during progress of the work. Mr. Denton 514 N.E. 101 St. M. §cores Owner's Name and Address No. Street Registered Architect and /or Engineer _._Orkin__ en - inating_co„I - i960 - . 27 AYE•. i Name and address of licensed contractor Location and legal description of lot to be built on: Lot Block Subdivisign Street and Number where work is to be done ,�- N.E. 101 St. M. SboreS - - -- ---- -- Nylon Tent Fumigation- F'iamigate State work to be done and purpose of building ( b l$ loe )- 110 - tms -- .-__ and for no other purpose. New Building Remodeling Addition Repairs No. of Stories To be constructed of Kind of foundation Roof Covering Estimated Total cost of improvements $ 3__C_7. P Amount of Permit $ Zone cubage required plan Cubage Distance to next nearest building Size of Building Lot Maximum live load to be borne by each floor___. I hereby submit all the plans and specifications for said building. All notices with reference to the building and its construction may be sent to The undersigned applicant for this building permit does hereby certify that he understands and accepts his obligations as an employer of labor under the Florida Workmen's Compensation Act, being Section 5966, Compiled General Laws of Florida, Permanent Supplement, and has complied with the rovisions thereof, and will require similar compliance from all contractors or sub- contractors employed by him in the work to be performed under this permit; and will post or cause to be posted for inspection on the site of the work such public notice or notices as are required by the Act. The undersigned agrees to employ only such subcont;acto y on work to be performed under this permit, as are licensed by Miami Shores Village. �e Remarks (Signed) STATE OF FLORIDA, COUNTY OF DADE. j ss Before me, the undersigned authority, a notary public, duly authorized to administer oaths and take acknowledgments, personally ap- peared - to me well known, and who, being by me first duly sworn, upon oath deposes and says that he is the of the above described construction, that he has carefully read the foregoing application, and that he did sign the same, and that all facts therein by him stated are true. Permit No / 12 7 7 Date ____.___r ._i!_ _'_. Disapproved _ D. to (Signed) _ . -- . Building pector BUILDING INSPECTION DEPARTMENT - MIs . - - 367 ;00 June 15, 1970 Read, Sworn to and Subscribed before me. Notary Public, State of Florida My Commission Expires_ ,19 PLANNING BOARD__. ____. __ DATE Chairman _ __ Member Member _ Member Member _ __ . Member Council Approved _Date Disapproved Date NOTE: A charge of $1.00 will be made for making corrections or changes to this application after approval has been obtained from the Planning Board. A re- inspection fee of 51.00 will be charged when such re- inspection is made necessary by improper notice for inspection or faulty materials and /or workmanship. Harold Architect PaILBDIG: All soil and vent piping shall be intermediate grade cast iron of sizes ICS indicated on the plumbing riser diagram. all water piping both hot and cold shall be galv. iron of sizea as indicated. Furnish and install a 600 precast concrete septic tank with 175 of b Orangebura drain tile. Plumber shafl pecifY available white enamel iron plumbing fixtures as &elected by the awner. T4101- All electric shall be according to code aad shall be run in rigid , tubing with no aaaller then. 0.2 Conductor in any branch circuit, Provide 100 amp. main service switch with a fuse type panel. Allow the sum of a50. for the purahase and installation of all electrical fixtures. . See sheet #2 for additional electricalaspecifications. FIRUPLACEsa Furnish and instellsam2ivaitation cast stone fireplace mantel with fire brick backing and quarry tile hearth, for use of an electric 2000 matt unit heater, All the sum of :2100. for the purchase and installation of one stock cast stene HOT WATta VATER:- Furni'dh'and install a 66 gal, General aectrie ;06�-1A galv. bat water nterage tank with simile 3000 watt unit. EOCFte Over entire roof area tin cap tack one layer of 30r roofing felt. Over 'es area riop on with asphalt one layer of 90,E slate surface roofing felt - lapping. all joints. .Provide necessary 22 ga.: .I. flashing at all valleys and -where roof intersects with wall. Provide 20 ga, 0.I. Drip strip around all eaves. Over entire roof area lay white cement shingle the roofing in a cement bed with double starting course at eaves. Roofer shall guarantee roof for a period of one year against all leaks and defects H . roid HcNei 1 - Aa chi'tect LATH' ABO PLA`..TEas- In all interior walls and ceilings except as otherwise noted, than have rock lath base. All internal and external corners of walls and ceilings and vale shell have 2" x 2" G.I. hardware cloth reinforcing. Where tile wainscot is called for, provide 0.1. e :panded metal lath base. Over all rock lath, apply 2 coats of :sum plaster - :enooth finish. . a11s and ceilings in two baths, in kitchen, shall have mhi.te putty coat finish. Under all tile, provicze cement plaster. Front entrance porch and garage shall have stecca ceilings of .I. expanded eetaneth. 002 1 Floor finishes throughout, except as otherwise noted, shall have 4 x c ear oak flooring, filled, stained, shellace 1, and waxed. Floors and steps on front entrar ec -orch and livire - -porch :hall Le red qua' :sy tile. Base on living perch ehsll be Zuar y tile. Provide ceresic ueelezed floore in two bathrooms and shower stall. Provide uuarry tile hearth. Provide quarry rrj tzle riser: on porch steps. Provide asphalt tile floor iu kitchen. In :;anise area provide s;:tooth cement finish on concrete slab. LILI,acRK:- All exteeior doors, fraros, a d ocrxLLee shall be ;1 ayprese or fir. All er or doors she. L1 be etook 3.eto type. Deer 2rsees, La.^.,ino f end :.. se shall oe stock Lapnolia or k'oplar. Kitchen cabinets shell be Bill- ...a;l.e accoraing to details on sheet #1 of 5-ply fir. Irovide 1" x 12 of fir ;shelf in eace clothes closet rith 1 1/8' diameter clothes rod under. Provide five 16" &helve* in linen cleeet. t `DG' s -. All caee:,ent sash throughout shall be stock steel stash as maeufacturee uy Lu ,Lupton or equal. eindowe shatl be cc..role° e with all hArdwere, bronze 16 <:esh screening set in bronze fraees, end glazed with quality L) D glass Get in white lead putty. Provide concrete precast ;vindov fr . es for ell oeenirt ;a. 0.a3.k casoleuielin Betting. After stucco work, caulk winders aeain before z .i .nlJin`.j. PAIW 1NG:- A11 interior and exterior woodwork throughout ohrnll receive three coats . 05 an approved brand of lead Bed oil paint. fell e.:terior etucoo ti ril 5 karte adobe brick Shall receive tee coats of "Armor" coat otucco eeint, Lil inte;rio v ache end ceilings except in two bathrooms vad kitchen shall receive; tiro coats of view ;in paint. a7.1.s and oeilingo in batvrco-ns and kitchen snail receive three ,oats of cnsee1 j dint. Paint all steel sash three coats of an approved brand of eotal en eel paint. TIZE' =`iOIt1C :- In each bathroom provide 4 :;lazed tile w inecot with G+ E;" w inscot over tub and in shower stall. erovide six set -in tile accessories in each ra . Whreom, Provide glazed bullnose tile window sills throughout. Provide Blazed tile irairboard in kitchen along with wainscot as shown in details on sheet ;r],. See flocrins specifications for additional tile work. H ;ARJ :- Builder shall provide all necessary rough hardware .fox the construction or this building. Allow the sun of $200. for the purchase of all finished hardware. VErETIAD BLINDS:- This contract shall include the instal atior of stock aluminum venetian blinds throughout. -2- • 0U1LINS' SPECIFICATIONS FOR A CBS RESIDLNCE FOR 1.R. AND MRS. R. DENTON TO BE BUILT ON LOT tt and 35: of LOT 5 BLOCK 95 mum' SHORES SUED, FLORIDA Harold kcNeil, Architect. SITE : - Soil condition is sandy loan and shall be considered as being level.: No trees Ear to be removed, Excavate footings to a depth of at least 10" or to solid ground, reraving all grass roots. FOUNDATIONS:- Foundations shall be reinforced concrete 2000# mix 'of sizes as indicated by typical wall section, sheet two. Footings shall be contained in wood forms, FOUNDATION AILS:* All foundation walls shall be standard 8" and 12" concrete blocks capped with ce..,ent leveling cap. Provide static 8" x 16" precast cement vents, screened 16 mesh bronze. Around entire perimeter of all foundation walla provide a 20 ga. G.I. termite shield. Solder all joints. Provide 2" x 4" plate treated with "Cel -cure .eo3.." FIRST FLOOR Fi 'fl' G: Provide 2 " x 10" - 16" 0.0, 0. structural grade LLYP floor joists treated with "eel-cure-sal". Provide 1" x 2 arose bridging at least once in every span. Over wood joists lay #2 - l x 6 T & G wood sheathing at right angles to joists. Provide reinforced concrete floor slabs where called for, EITXOR WALLS:- All exterior walls shall be standard 8" x 8" x 16" concrete block laid up true and plumb with masonry -mix mortar. Provide standard lid'• : 2 16" U shaped concrete tie beam blocks, with reinforced ccm..Srete as called for. Cap all exterior walls with 2 x 6 treated wood plate bolted every 31 o.c, with 12" x 12" anchor bolts. All exterior walla shah, receive two coats of Vortlard Cement stucco - sxooth finish, On all exterior walls, provide treated 1" x 2" furring strips 16" o.c. INTERIOR PAsTITIONS,.- All interior partitions shall be L..2 SLIP studs 2" x 4" 16" o.c. wth single plate at floor and double plate at head. Provide fire stops once z► in heighth. Truss all openings over ' in width, CEILING JOIS a AND ROOF F'w A?.;I2tG:- Ceiling joists shall be #1 LLIP of sues as indicated on the plans. Hoar r.4 ters shat.. be #1 structural grade 2" x 8" LLYP anchored to wood plate with hurricane anchors 16" o.c, Also spike to ceiling joists. Provide 1 x 6" cross bracing a nd collar beams 48" o.c. Over entire roof area ley '2 - 1" x 6" T &G wood sheathing. HAROLD MCNEIL A R C H I T E C T 7 MIAMI FLORIDA