ROOFINGPERMIT APPLICATION FOR MIAMI SHORES VILLAGE
Date 1 0 —1 2 — 9 5 Job Address 4.88 N . E . 101 Street Tax Folio
Legal Description Historically Designated: Yes No
Owner/Lessee / Tenant Mr. Reynolds Master Permit # 3.0S6,
Owner's Address 488 N. E. 101 Street
ContractingCo,Quality Roofing Contractor, Inc..
Qualifier Carlos Arocho 751-0382
State # RCoo 5 8 6 2 7 Municipal # Competency # 17889 Ins. Co.
Architect/Engineer Address
Bonding Company Address
Mortgagor Address
Permit Type (circle one): BUILDING ELECTRICAL PLUMBING MECHANICAL ROOFING PAVING FENCE SIGN
WORK DESCRIPTIONTear off roof to wood deck, tin cap 301b. ASTM felt as per building
code, mop on with hot asphalt one layer of 901b. ASTM felt, install valley
and eave metal where required and install Spanish S Grey Colorthru Tile
mortar set approved.
Square Ft. 30 s q- Estimated Cost (value) $ 12,000.00
WARNING TO OWNER: YOU MUST RECORD A NOTICE OF COMMENCEMENT AND YOUR FAILURE TO DO SO MAY
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY (IF YOU INTEND TO OBTAIN FINANCING,
CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.)
Application is hereby made to obtain a permit to do work and installation as indicated above, and on the attached addendum (if applicable). I
certify that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that separate
permits are required for ELECTRICAL, PLUMBING, SIGNS, POOLS, ROOFING and MECHANICAL WORK.
OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable
laws regulating construction and zoning. Furthermore, I authorize the above -named contractor to do the work stated.
Signature of owner an
rq
do President
FEES: PERMIT t ,O RADON
APPROVED:
Zoning Building
Mechanical
Plumbing
Date /p -/3 2i '
/
.4 , I _ I 'A 44 A4a.4111 D - 23
Notary as to t er and/ • • • ' >
My Commission Expire 0°ri' a COMMISSIHE 324212
:is -
£ EXPIRES: October 10, 1997
6 N; ' Banded Thru Notary Public Underwriters
C.C.F.
Address
Phone
Signature of Contractor or Owner- Builder
Notary as to Con actor or
My Commission Expires:
251 N.W. 99th Street
Electrical
754 -0091
orp
I n
•R
TOTAL DUE
/D x/3.9
Date
•1'YLOU HERNANDEZ
MY COMMISSION d CC 324212
EXPIRES: October 10, 1997
Os Bonded Thm Notary Public Undervotters
D -/ 3 - 5J
Engineering
s
W TNESS my hand and Offici
HARVE , g" LERK,
B y
aiAJE 0. FLORIDA, COUNTI' 0; DAD
HEREBY CERTIFY fha` f.is is a 1 : •PY
originalfilodjn7ihi of ce on
PERMIT NO.
STATE OF FLORIDA:
COUNTY OF DADE:
3. Owner(s) name and address: Mr . Reynolds
Interest in property: Man pr
Name and address of fee simple titleholder: N/A
Amount of bond $ 0
6. Lender's name and address: N/A
^� Public
. Name
pmmission Expires.
ho ����
y_gt
, A 0. 19
Seal.
coif and County Cowls
D.C.
Sworn to and subscribed before me this /3 day of
NOTICE OF COMMENCEMENT
A RECORDED COPY MUST BE POSTED ON THE JOB SITE AT TIME OF FIRST INSPECTION
. TAX FOLIO NO.
9 58436442 1995 .00T 26 10:49
THE UNDERSIGNED hereby gives notice that improvements will be made to certain real property, and in accordance with
Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement.
1. Legal description of property and street address: 488 N.E. 1 01 Street
Miami Shores . Fl nri rid 331 38
2. Description of improvement: Install new Tile Roof .
5. Surety:(Payment bond required by owner from contractor, if any)
Name and address: N/A
488 N.E. 101 street Miami Shores, Florida 33138
4. Contractor's name and address: Quality Roofing Contractor, Inc.
251 N.W. 99th Street Miami, F'lnrirla 33150
7. Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided
by Section 713.13(1)(a)7., Florida Statutes,
Name and address: N/A
8. In addition to himself, Owner designates the following person(s) to receive a copy of the Lienor's Notice as provided in
Section 713.13(1)(b), Florida Statutes.
Name and address: N/A
x )% s /f4
Signature of Owner � � Jl
Print Owners Name /rVI1/i 4m .S, e (F J'1a /d
19 9,, c
9. Expiration date of this Notice of Commencement: (the expiration date is 1 year from the date of recording unless a
different date is specified)
Prepared by: Carlos Arocho
Quality Roofing Contractor, Inc
Address: 251 N.W. 991-h street '
' 11
1:1 _ . 1 . _ A A A. .1—.A.A.■
MY COMMISSION II CC 324212
EXPIRES: Octolw 10, 1097
ays.c.v Bonded TM Notary Public Underwriters
129.01.52 2/93
Job Address: 7 ff / 0 / Jr,
Underlavment (continued):
Check all of the following which apply to the proposed underlayment
for use with the proposed tile system assembly:
N ASTM #30 asphalt saturated felt with:
Manufacturer: e eJ ; C- rk s rj
• ASTM #15 asphalt saturated felt with:
Manufacturer:
Q Mineral Surfaced Roll Roofing with:
Manufacturer:
• Other:
Type:
Manufacturer:
lx - fn U ; c_
Underlavment Fasteners (if applicable):
Check one of the following which apply to the proposed
underlayment attachment:
lid Minimum 12 ga. electro - galvanized roofing nail with
minimum 32 ga. x 1' / tin cap:
Length: Pit-1 "
Manufacturer:
O Other:
Type:
Length:
Manufacturer:
Contractor: Quo/. } - r gook, £ L 14?c_ Process No.
O 19" overlap
O " overlap 5. Related Accessories:
V 4" overlap
O 19" overlap
O 6" overlap
O 4" overlap
O 19" overlap
O 6" overlap
6Y4" overlap
.k. T ry
Mortar or Adhesive Set Tile Systems
Page - 3
Spacing (per tile system assembly Product Control Approval):
Field:
Laps:
" o.c.
" o.c.
Edge Metal (refer to Section 3408.2 of the South Florida Building
Code):
Type:
Dimensions:
C ' I Jck.v-.i 2-c
Gauge or Thickness: 0
Finish: C-9(1 J .
Note: All edge metal shall be nailed on the flange and nailed or clipped
at the face in compliance with the provisions set forth in Dade
County Protocol PA 111, marked Appendix 'U' in the South
Florida Building Code.
Adhesives (check one of the following):
0 Cold Adhesive:
Type:
Manufacturer:
Flashing Cement:
Type: ftSiM 0
Manufacturer: 9 S Y co
Job Address: L/ ? /v .E )Dl ST
Contractor: 0e / jt KC)0 :',1) �o
Ridge Height: Eave Height: Roof M an Height
1 1 feet 1 feet /.2/ feet
BUILDING INFORMATION 111
Job Site Identification:
Mortar or Adhesive Set Tile Systems
Page - 6
Process No.
Insert Building Ridge Height, Eave Height and Roof Mean Height.
Also insert applicable information pertaining to the building below.
( See ASCE 7 -88 Fact Sheet Attached )
C
Exposure Category:
Classification Catcgory:
At I lurricancc Occanlinc7:
Basic Wind Speed at
Building Location- 110 mph
Building Condition based on
% of openings:
(See Table 9 ofASCE 7-88)
Ground Level
Job Address: 1 438 /1) E io, 5T
Manufacturer:
❑ ASTM #15 asphalt saturated felt with:
Manufacturer:
r
Ei Mineral Surfaced Roll Roofing with:
Manufacturer:
❑ Other:
Type:
Manufacturer:
❑ Other:
Type:
Length:
Manufacturer:
(r f c
Underlayment Fasteners (if applicablel:
Ridge Height: Eave Height:
1 y feet 1 1 feet
BUILDING INFORMATION #1
Job Site Identification:
Job Address: 1. /73 I , F. / 0/ S r, Contractor:
Underlayment (continuedl:
Check all of the following which apply to the proposed underlayment
for use with the proposed tile system assembly:
m ASTM #30 asphalt saturated felt with:
O 19" overlap
❑ " overlap
fd' 4" overlap
P
Check one of the following which apply to the proposed
underlayment attachment:
Id Minimum 12 ga. electro - galvanized roofing nail with
minimum 32 ga. x i / tin cap:
Length: Pig "
Manufacturer:
Mortar or Adhesive Set Tile Systems
Page -6
D 19" overlap
O 6" overlap
O 4" overlap
O 19" overlap
O 6" overlap
liY4" overlap
Contractor: at / � t., �ZOo 1 e hh (/ / Process No.
Roof an Height
/2/) feet
Mortar or Adhesive Set Tile Systems
Page - 3
Insert Building Ridge Height, Eave Height and Roof Mean Height.
Also insert applicable information pertaining to the building below.
( See ASCE 7 -88 Fact Sheet Attached )
C
Exposure Catcgory:
Classification Catcgory:
M I iurricancc Occanlinc?:
Basic Wind Speed at
Building Location: 110 mph
Building Condition based on
% of openings:
(See Table 9 of ASCE 7 -88)
Ground Level
ou.41. y 404' t 1 � Process No.
Spacing (per tile system assembly Product Control Approval):
Field:
Laps:
Type:
5. Related Accessories:
Edge Metal (refer to Section 3408.2 of the South Florida Building
C•de):
Dimensions:
Finish:
❑ Cold Adhesive:
Flashing Cement:
" o.c.
" o.c.
Type:
Manufacturer:
Type:
Manufacturer:
•
Cur.; LLcl
2.v:
Gauge or Thickness: 2-(c c .
Note: All edge metal shall be nailed on the flange and nailed or clipped
at the face in compliance with the provisions set forth in Dade
County Protocol PA 111, marked Appendix 'U' in the South
Florida Building Code.
Adhesives (check one of the following):
A-s 0
�{
Job Address:
WO 13,x. loi sT.
Adhesives (continued):
Ventilation System (check one or more of the following):
Job Address: • . e . / 0) ST
Contractor:
Note: Application of adhesives shall be in compliance with the Roofing
Component Product Control Approval and the minimum
requirements set forth in Subsection 3403.5(e)(4)(cc) of the South
Florida Building Code.
The following information is required to confirm compliance with
Subsection 3401.4(e) of the South Florida Building Code.
O Ridge: Type Size in'
Er Soffit: Type Sr e.erll. ' Size L C /a in'
Note: If underlayment is comprised of a self - adhered membrane, both soffit
and ridge ventilation systems are required, unless a base sheet is
applied as an anchor sheet below the self - adhered underlayment.
Note: The Tile System Assembly shall be installed in strict compliance
with the application instructions enumerated in the Product
Control Approval. A permit shall be issued for application of the
specified Tile System Assembly only. Any change to the specified
Tile System Assembly shall require submission of a revised
SECTION II with a copy of SECTION I, noting the permit
number issued.
Mortar or Adhesive Set Tile Systems
Page - 4
Contractor: Otter /. 1 �Z� j � HI7 c eft) r Process No.
Ridge Venting:
t 4f applicable
Deck:
Type %Apr')O
Thtebtees 1 y
Underlayment: 30 h . PrST Pt
Underlayment t
Fastener: ) )4 r e\co is
3
12"
FILL IN API'LICAI3LE ROOFING COMPONENTS WIIICII MAKE UP
TILE SYSTEM ASSEMBLY. INSERT ANY ADDITIONAL LEADERS
INDICATING ADDITIONAL ROOFING COMPONENTS NOT SI !OWN
ON THIS PAGE. ( Where Roofing Componcnt not used in Tile System
Assembly, fill in with "N /A ". )
Head Lap Dimension: "
(minimum Y un/ese otherwise ep.cilied
in the rile ryttem assembly Product Control
APPromQ
Mortar /Adhesive:
Tile: SaAn.sit S &fC
Mc Co hoof
T•I
Tile Fastener: q'
Edge Metal or Gutter
Fastener: / yy '•r, h
te n: 15
Bird Stop: A) 1
(I1/applicable)
Edge Metal "
or Gutter: C r t>avt zeCe
o / .2'/-2''
aGc�cr
Existing or Proposed
Soffit Venting: ,S('r'
V = / Ve..4
DETAIL #1
Job Site Identification:
Mortar or Adhesive Set Tile Systems
Page - 5
Additional Notes:
J No.
•
Job Address: Lyn lv F . 10/ ST.
Contractor: Ot -4 1 f lepd4)-,. Y
l
Sketch Roof Plan, indicating all dimensions, slopes and any roof top equipment.
Also insert variable labeled "a" which represents perimeter and corner dimensions
per Chapter 23 of the South Florida Building Code.
(See ASCE 7 -88 Fact Sheet Attached )
3y
BUILDING INFORMATION #2: Roof Plan with Perimeter and Corner Dimensions
Job Site Identification:
Mortar or Adhesive Set Tile Systems
Page - 7
Process No.
Job Address: L/ 8 N • E. 101 S r, Contractor: 014.4 1:47 _r j CDrdic OrProcess No.
The undersigned certifies that the Mortar or Adhesive Set Tile System
Assembly is in compliance with the plans, specifications, and details
submitted by the architect.
STATE OF FLORIDA - COUNTY OF DADE
Before me this day personally appeared ( - o c Pc-rock c>
who, being first duly sworn, deposes and says that all information submitted
herein is true and correct.
Sworn to and subscribed be
191 .
My commission expires:
L1
Licensed Contractor / Owner
Signature f�
th da o f v/
MARYLOU HERNANDEZ
MY COMMISSION # CC 324212
EXPIRES: October 10, 1997
nde
Not >y Public
State of Florida
Mortar or Adhesive Set Tile Systems
Page - 8
Job Address: 1 p' /O. f. / D / ST
Project Information (continued):
If the proposed undcrlaymcnt is self - adhered, have you complied
with the venting requirements of Section 2913.3 (b), (c) and (d) of
the South Florida Building Code?
yes no
Tile:
Tile Name:
Manufacturer:
Tile Material:
❑ Clay
1'Concrete
❑ Other:
no
4. The Tile System Assembly:
Product Control Approval Number:
Mortar or Adhesive:
Are all related accessories approved for use with this tile system
assembly?
Are the proposed edge metal attachment fasteners in compliance
with the requirements of the South Florida Building Code (minimum
12 ga. annular rin shank, corrossion reisistant nails)?
no
The following information is required to confirm compliance with
Subsections 3403.5(a) and (c) and Section 3404 of the South Florida
Building Code.
SQran`isk S Gce
Me.Vrr Rr9f-
qy- 1011.01
Contractor:
Check one of the following which apply to the proposed tile
securement for use with the proposed tile system assembly:
Mortar or Adhesive Set Tile Systems
Page - 2
L/ Mortar:
❑ Adhesive:
_Process No.
Manufacturer:
Mixing Ratio:
Type:
Manufacturer:
0.--Lr-1 o 1 C—
,1'•
Tile Fasteners (for first three courses if roof pitch exceeds 5 ":12"
and is less than or equal to 7 ":12 "):
Check one of the following which apply to the proposed tile
fasteners (for the first three courses) for use with the proposed tile
system assembly:
❑ Minimum 12 ga. galvanized roofing nail:
E1
Length:
❑ Other: Type:
Length:
Note: All tiles shall be installed in compliance with the provisions set
forth in the tile system assembly manufacturer's Product Control
Approval and the minimum requirements set forth in Subsections
3403.5(c) and 3404.2 of the South Florida Building Code. Tile
fasteners in the first three courses (if applicible) shall be of
sufficient length to penetrate the sheathing a minimum of 1" or
through the sheathing thickness a minimum of / ", whichever is
less.
Underlayment:
The following information is required to confirm compliance with
Section 3403.5(b) of the South Florida Building Code.
Job Address: 1 4% @3 ,F I C) 1 S r ez�
APPENDIX 'E'
METRO -DADE UNIFORM BUILDING PERMIT
SECTION II
MORTAR OR ADHESIVE SET TILE SYSTEMS
1. General
Contractor:
The information provided in this Section is required to confirm
Product Control Approval of the proposed tile system assembly;
confirm compliance with the wind load requirements of Chapter 23
of the South Florida Building Code (SFBC); and confirm compliance
with Sections 3403.5 and 3404 of the South Florida Building Code.
2. Documentation
The following documents are required for submission with the
Uniform Building Permit application:
► Two (2) copies of the proposed tile system assembly's and
associated roofing component's Product Control
Approval(s).
► One (1) copy of the tile system assembly and/or roofing
component(s) manufacturer's published application
instructions and literature.
► All documents attached herein, filled out and completed in
full.
3. Project Information
Check one of the following:
❑ view Construction
Re -Roof
Nole: Mortar or adhesive set tile systems are not acceptable as recover
applications.
12301.158
Mortar or Adhesive Sct Tile Systems
Page - 1
Q ur, . & I : nr.) Q nt , G Process No.
Is the deck solid sheathed? (circle 'yes' or 'no')
yes no
Deck Tyne (check one of the following:
❑ Nominal'' 'A" Plywood (for re -roof only)
❑ Nominal'/," Plywood
Ig Wood Plank )1( (, "
❑ Other (fill in)
Roof Pitch (fill ink:
3 "
Note: Mortar or adhesive set tile systems shall not be installed at a pitch
greater than 7 ":12 ". Mortar or adhesive set tile applied at a
pitch greater than 5 ":12" and less than or equal to 7 ":12" shall
have the first three courses of tile nailed with not less than one
nail per tile. As an alternate, the first three courses of tile may be
applied in mortar over a single layer of minimum 12 ga. wire
mesh with square openings of not less than '/," which is
mechanically attached to the sheathing with not less than one nail
per 2 ft
Circle 'ves' or 'no' for each of the following:
Have you attached two copies of the tile system manufacturer's
Product Control A ' . royal for the proposed tile system?
no
Have you attached a copy of the tile system assembly and/or
roofing component(s) manufacturer's published, application
instructions and other literature
no
Is the proposed underlayment approved for use with this tile
system assembly?
no
• METRODADE
PRODUCT CONTROL NOTICE OF ACCEPTANCE
Metro Roof Tile, Inc.
11350 N.W. South River Drive
Miami, FL 33178
Your application for Product Approval of:
Spanish S
under Chapter 8 of the Metropolitan Dade County Code governing the use of Alternate Materials and
Types of Construction, and completely described in the plans, specifications and calculations as submitted by:
Redland Technologies, The Center for Applied Enginering, Inc., and Testwell Craig
Laboratories & Consultants, Inc.
has been recommended for acceptance by the Building Code Compliance office to be used in Dade
County, Florida under the specific conditions set forth on pages 2 et. seq. and the Standard Conditions
on page 3.
This approval shall not be valid after the expiration date stated below. The Office of Code Compliance
reserves the right to secure this product or material at anytime from a jobsite or manufacturer's plant for
quality control testing. If this product or material fails to perform in the approved manner, the Code
Compliance Office may revoke, modify, or suspend the use of such product or material immediately. The
applicant shall re- evaluate this product or material should any ammendments to the South Florida Building
Code be enacted affecting this product or material. The Building Code Compliance Office reserves the
the right to revoke this approval, if it is determined by the Building Code Compliance Office that this
product or material fails to meet the requirements of the South Florida Building Code. The expense of
• such testing will be incurred by tlye manufacturer.
Acceptance No.:94- 1017.01
Expires:06 /15/98
METROPOLITAN DADE COUNTY. FLORIDA
METRO -DADE FLAGLER BUILDING
BUILDING CODE COMPLIANCE OFFICE
SUITE 1603
METRO -DADE FLAGLER BUILDING
140 WEST FLAGLER STREET
MIAMI, FLORIDA 33130 -1563
(305) 375 -2901
FAX (305) 375 -2908
PRODUCT CONTROL SECTION
(305) 375 -2902
FAX (305) 372 -6339
Raul Rodriguez
Product Control Supervisor
THIS IS THE COVERSHEET, SEE ADDITIONAL PAGES FOR SPECIFIC AND GENERAL
CONDITIONS
BUILDING CODE COMMITTEE
This application for Product Approval has been reviewed by the Metropolitan Dade County Building
Code Compliance Department and approved by the Building Code Committee to be used in Dade
County, Florida under the conditions set forth above. •
Approved:06 /15/95 -
S V anger,
Director
Building Code Compliance Dept.
Metropolitan Dade County
Applicant:
Metro Roof Tile, Inc.
11501 Northwest 117th Way
Medley, Florida 33178
PRODUCT CONTROL NOTICE OF ACCEPTANCE
ROOFING SYSTEM APPROVAL
Category: Prepared Roofing
Sub - Category: High Profile Tile
Type: Nail - on/Mortar Set/Adhesive Set
Sub -Type: Concrete
System Description
Product Control No.:
Approval Date:
Expiration Date:
JUN 1 5 1995
JUN 1 5 1998
94- 1017.01
Metro Roof Tile, Inc., located in Medley, Florida, manufacturers clay roof tile for nail -on, mortar
set or adhesive set applications. This Product Control Approval relates to Metro Roof Tile's "Spanish S"
high tile profile.
tell
11 1 -
11 S -
1 •
The Metro Roof Tile "Spanish S" tile profile is available in a variety of colors and has matching
trim pieces used for rake hip, ridge hip, and valley terminations. These accessories are manufactured for
all profiles and form a part of this Product Control Approval.
The Metro Roof Tile "Spanish S" roof tile has been tested in compliance with the South Florida
Building Code requirements for concrete, nail -on, mortar set or adhesive set tile applications. See the
"Profile Drawing" section in this Approval for the Metro Roof Tile "Spanish S" profile drawing. The
Metro Roof Tile "Spanish S" profile has been tested for both wind characteristics and static uplift
performance, therefore, any consideration for installation shall be done as a 'Moment Based System'.
Data for attachment calculations is noted in Tables 1 through 4 of this Approval.
Contact:
Fernando Arias
Metro Roof Tile, Inc.
11501 Northwest 117th Way
Miami, FL 33178
(305) 558 -6712
2
Raul Rodriguez
Test Product
Product Dimensions Specifications Description
Spanish 'S' Concrete 1= 18" PA 112 High profile, interlocking, one - piece,
Roof Tile w = 10' /z" 'S' shaped, concrete roof tile equipped
'A" thick with two nail holes and a single roll.
For nail -on, mortar set and adhesive set
applications.
Trim Pieces
TRADE NAMES OF PRODUCTS MANUFACTURED OR
LABELED BY APPLICANT
1= varies
w = varies
varying thickness
PA 112 Accessory trim, clay roof pieces for
use at hips, rakes, ridges and valley
terminations. Manufactured for each
tile profile.
Raul Rodriguez
Product Control No.: 94- 1017.01
Product
#30 Felt
#43 Coated Base
Sheet
Mineral Surface Cap
Sheet
Dimensions
N/A
N/A
N/A
Lenzingtex -ZB 140 59" x 164' roll
Underlayment 22 Ibs /roll
Rainproof I1
Ice and Water Shield
Mopping Asphalt
Flashing Cement
TRADE NAMES OF PRODUCTS MANUFACTURED OTHERS
30" x 75' roll
36" x 75' roll
or
60" x 75' roll
36" x 75' roll
N/A
N/A
Test
Specifications
ASTM D 226
type 11
ASTM D 2626
ASTM D 249
PA 104
PA 104
PA 103
ASTM D 312
type III or IV
ASTM D 4586
4
Raul Rodriguez
Product Control No.: 94- 1017.01
Product
Description
Saturated organic felt
to be used as a nailed
anchor sheet.
Saturated and coated
organic base sheet for
single or double ply
underlayment.
Mineral surfaced
asphalt roll roofing
for use as a top ply in
a double ply
underlayment system.
Single ply, nail -on
underlayment.
Single ply, nail -on
underlayment with 2"
self - adhering top
edge.
Self- adhering
underlayment for use
as a top ply in a two
ply underlayment
system with
Approved #30 or #43
as the base layer.
Asphalt for bonding a
mineral surface cap to
a mech. attached base
sheet in a double ply
underlayment system.
Cut back, asphalt
based, asbestos free,
fiber reinforced,
trowel grade cement
for repair and flashing
applications.
Manufacturer
generic
generic
generic
Lenzing
Performance, Inc.
with current PCA
Protect -O -Wrap, Inc.
with current PCA
W.R. Grace Co.
with current PCA
generic
generic
Product
Asphalt Primer
Roofing Nails
Tin Caps
Wood Battens
Tile Nails
Tile Screws
Roof Tile Mortar
( "Ti IeTiteTM ")
Roof Tile Adhesive
( "Polypro® AI-I160 ")
Dimensions
N/A
min. 12 ga. with
'/ head
min. 32 ga.
min. 1 o.d.
max. 2" o.d.
vertical
min. 1 "x4"
horizontal
min. 1" x 4" for use
with vertical battens
or
min. 1" x 2" for use
alone
min. 8d x 2V2" or
min. 10dx3"
#8 x 2 %2" long
0.335" head dia.
0.131" shank dia.
0.175" screw thread
diameter
N/A
N/A
Test
Specifications
ASTM D 41
PA 114
Appendix E
PA 114
Appendix E
Wood Preservers Salt pressure treated
Institute LP - 2 or decay resistant
lumber battens
PA 114
Appendix E
PA 114
Appendix E
PA 123
See PCA
5
Raul Rodriguez
Product Control No.: 94- 1017.01
Product
Description
Cut back, asphalt
based coating used to
facilitate bonding of
dissimilar materials.
Annular ring shank,
hot dipped, electro or
mechanically galv.
roofing nails for use
in underlayment
attachment.
Corrosion resistant
circular disc for use in
underlayment
attachment
Corrosion resistant,
screw, smooth or
annular ring shank
nails.
Corrosion resistant,
coated, coarse thread
wood screws.
Prepared mortar mix
designed for mortar
set roof tile
applications.
Two component
polyurethane adhesive
designed for adhesive
set roof tile
applications.
Manufacturer
generic
generic
generic
generic
generic
generic
Bermuda Roof
Company, Inc.
with current PCA
Polyfoam Products,
Inc.
with current PCA
Product
Hurricane Clip &
Fasteners
Valley Flashing
Drip Edge
Dimensions
Clips
niin. 'A" width
min. 0.060" thick
Clip Fasteners
min. 8d x 11/4"
min. 26 ga.
min. 16" width
min. 26 ga.
min. 2" face flange
min. 2" deck flange
Test
Specifications
PA 114
Appendix E
ASTM A 525
PA 111
6
Raul Rodriguez
Product
Description Manufacturer
Corrosion resistant generic
bronze, aluminum,
stainless steel,
galvanized steel or
plastic attachment
clips for supplemental
tile attachment. Clips
are installed with
corrosion resistant
roofing nails
compatible with the
clip.
Galvanized steel
valley flashing
Product Control No.: 94- 1617.01 '
Galvanized steel drip
edge
generic
generic
Test Agency
Redland Technologies
Redland Technologies
The Center for Applied
Engineering, Inc.
The Center for Applied
Engineering, Inc.
The Center for Applied
Engineering, Inc.
Redland Technologies
Redland Technologies
Redland Technologies
Redland Technologies
The Center for Applied
Engineering, Inc.
Testwell Craig Laboratories
& Consultants, Inc.
TEST REPORTS
Test Identifier
7161 -03
Appendix III
7161 -03
Appendix III
25- 7200 -1
94 -084
94 -083
7161 -03
Appendix II
Report Dated
Aug. 1, 1994
P0647 -01
PO402
Project No. 307025
Test #MDC -78
Lab ! EA -25
Tech: G. Suarez
Product Control No.: 94-1017.01
Test Name /Report pate
Static Uplift Testing Dec. 1991
PA 102
Static Uplift Testing
PA IO2(A)
Static Uplift Testing
PA 102
(Quik -Drive Screws, Battens)
Static Uplift Testing
PA 101
(Mortar Set)
Static Uplift Testing
PA 101
(Adhesive Set)
Wind Tunnel Testing
PA 108
(Nail -On)
Wind Tunnel Testing
PA 108
(Nail -On)
Wind Tunnel Testing
PA 108
(Mortar Set)
Withdrawal Resistance
Testing of screw vs. smooth
shank nails
Wind Driven Rain
PA 100
Physical Properties
PA 112
7
Raul Rodriguez
Dec. 1991
Feb. 1995
May 1994
April 1994
Dec. 1991
Aug. 1994
Aug. 1994
Sept. 1993
Oct. 1994
July 1994
Deck Type: Wood, Non-insulated
Deck Description: New Construction
19 / 32 " or greater plywood or wood plank.
SYSTEM A: Counter - Batten Application
Slope Range:
Underlayment:
Vertical Battens:
Horizontal Battens:
Roofing Tile:
Comments:
2":12" to 7 ":12"
Note: Counter - Battens, as noted helm'', are required for slope range
2":12" to less than 4":42" a and e optional for slopes of 4":12" to
7 ":12 ". For slopes exceeding 7"/12 ", refer to System C.
Install underlayment system in compliance with Dade County Application
Standard PA 118.
Install vertical battens in compliance with Dade County Application Standard
PA 118
Install horizontal batten
Standard PA 118.
SYSTEMS
Install tile in compliance with Dade County Application Standard PA 118.
(See "Data for Attachment Calculations" included in this Approval.)
1. For re -roof applications,' /,," plywood is an acceptable substrate.
8
Product Control No.: 94- 1017.01
in compliance with Dade County Application
Raul Rodriguez
SYSTEMS
(CONTINUED)
Deck Type: Wood, Non - insulated
Deck Description: New c struction 19 / 12 " or great plywood or wood plank.
SYSTEM B: Direct De Application
Slope Range: 4 ":12" to 7 ": I
Note: System B only acceptable in this slope range. For slopes less than
4 ":12 ", r fe to System A. For slopes in excess of 7 ":12 ", refer to
System
Underlayment: Install unde ayment system compliance with Dade County Application
Standard P • 118.
Roofing Tile: Install tile in compliance with Dade .. fty Application Standard PA 118.
(See 'Data for Attachment Calculations" inclu ectittpis Approval.)
Comments: 1. /For re -roof applications, 15 / 32 " plywood is an acceptable substrate.
9
Raul Rodriguez
Product Control No.: 94- 1017.01
Deck Type: Wood, Non - insulated
Underlayment:
Standard PA 119.
SYSTEMS
(CONTINUED)
Deck Description: New construction 19 / 32 " or greater plywood or wood plank.
SYSTEM C:. Horizontal Batten Application
Slope Range: N 4 ":12" or greater
'Note: Horizontal battens, as noted below, are required for slopes in excess
\ of 7 ":12" and are optional for slopes of 4 ":12" to 7 ":12 ". For slopes
-,less than 4'12 ", refer to System A.
Install underlayment system in compliance with Dade County Application
Horizontal Battens: Install horizontal battens..,in compliance with Dade County Application
Standard PA 119.
Roofing Tile: Install tile, in compliance with Dade County Application Standard PA 119.
(See "Data for Attachment Calculations" included in this Approval.)
Comments: 1. For re- is roof applications, /,, plywood is an acceptable substrate.
1°
Raul Rodriguez
Product Control No.: 94- 1017.0I
Underlayment:
Roofing Tile:
Comments:
SYSTEMS
(CONTINUED)
Deck Type: Wood, Non - insulated
Deck Description: New construction 19 /72 " or greater plywood or wood plank.
SYSTEM D: Mortar or Adhesive Set Application
Slope Range: 2 ":12" to 7 ":12"
Note: System D is only acceptable in this slope range.
Product Control No.: 94- 1017.01
Install underlayment system in compliance with Dade County Application
Standard PA 120. (See System Limitation #5.)
Install tile in compliance with Dade County Application Standard PA 120.
(See "Data for Attachment Calculations" included in this Approval.)
1. For re -roof applications, 15 / 12 " plywood is an acceptable substrate.
11
Raul Rodriguez
SYSTEM LIMITATIONS
Product Control No.: 94- 1017.01
1. The standard minimum roof pitch for Metro Roof Tile's "Spanish S" high profile tile shall comply
with Dade County Application Standards PA 118, PA 119 or PA 120, depending on the method of
installation.
2. For nail -on applications, fasteners for mechanical attachment of tiles shall have a head diameter
larger than that of the preformed holes in the tile.
3. System installation shall be in compliance with the system specifications outlined in this Product
Control Approval. The method of attachment utilized shall provide sufficient attachment resistance
expressed as a moment to meet or exceed the required moment of resistance determined in
compliance with Dade County Protocol PA 115 or PA 127. The Metro Roof Tile "Spanish S" tile
profile has been tested for both wind characteristics and static uplift performance, therefore,
attachment calculations for installation in compliance with PA 115 or PA 127 shall be done as a
'Moment Based System'
4. For mortar or adhesive set tile applications, a field static uplift test by a Dade County accredited
testing agency, in compliance with Dade County Protocol PA 106, shall be performed.
5. For mortar set tile applications, 30/90 hot mopped underlayment applications may be installed
perpendicular to the roof pitch unless stated otherwise by the underlayment material manufacturer's
published literature.
6 All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo for
identification in the field.
7. Applications for roofing permits shall include a completed Section 11 of the Uniform Building
Permit, a copy of Metro Roof Tile's current specifications and details, a copy of this Product
Control Approval and a copy of the Product Control Approval of any Roofing Component used in
the proposed tile application. Reference shall be made to appropriate data for the required fire
rating.
8. The applicant shall retain the services of a Dade County certified testing laboratory to maintain
quality control in compliance with the South Florida Building Code and related protocols. Samples
taken shall be in compliance with Dade County Protocol PA 112, Appendix 'A'.
9. Any amendments to these provisions shall be in compliance with Sections 203 and 204 of the South
Florida Building Code.
Raul Rodriguez
Table 3: Attachment Resistance Expressed as a Moment - M, (ft -Ibf)
for Nail -On Systems
Tile
Profile
TILE
APPLICATION
APPROVED
NAILS
APPROVED
SCREWS
APPROVED
FIELD CLIP
WITH:
APPROVED
EAVES CLIP
WITH:
1 nail
2 nails
1 screw
2 screws
1 nail
2 nails
1 nail
2 nails
Metro Roof Tile
Spanish 'S' Tile
Battens
N/A
N/A
N/A
26.80
N/A
N/A
N/A
N/A
Direct Deck
6.20
8.40
28.70
31.80
21.20
25.30
26.90
34.90
Table 2: Restoring Moments due to Gravity - M (ft -Ibf)
Tile
Profile
3 ".12"
or less
4 ":12"
5 ":12"
6 ":12"
7 ":12" or
greater
Battens
Direct
Deck
Battens
Direct
Deck
Battens
Direct
Deck
Battens
Direct
Deck
Battens
Direct
Deck
Metro Roof Tile
Spanish 'S' Tile
6.70
7.10
6.60
7.00
6.46
6.84
6.30
6.67
4.08
N/A
Table 4: Attachment Resistance Expressed as a Moment - M, (ft -Ibf)
for Mortar or Adhesive Set Systems
Tile
Profile
Tile
Application
Attachment
Resistance
Metro Roof Tile Spanish 'S' Tile
Mortar Set
24.50
Adhesive Set
66.50
DATA FOR ATTACHMENT
CALCULATIONS
Product Control No.: 94- 1017.01
13
Raul Rodriguez
Table 1: Aerodynamic Multiplier - X (ft')
Tile
Profile
X (ft')
Batten Application
X (ft')
Direct Deck Application
Metro Roof Tile Spanish 'S' Tile
0.29
0.31
DATA FOR ATTACHMENT
CALCULATIONS
Product Control No.: 94- 1017.01
13
Raul Rodriguez
PROFILE DRAWING
METRO ROOF TILE SPANISH'S' TILE.
Raul Rodriguez
Product Control No.: 94- 1017.01
METRO DADE METROPOLITAN DADE COUNTY; FLORIDA
METRO -DADE FLAGLER BUILDING
,NOTICE OF ACCEPTANCE: STANDARD CONDITIONS
UUILDINO CODE COMPLIANCE DEPARTMENT
SUITE 1603
METRO-DADE FLAOLER BUILDING
140 WEST FLAOLER STREET
MIAMI, FLORIDA 33130.1503
(305) 375.2001
FAX (305) 375 -2000
1. Extensions of Acceptance may be considered alter a new application has been filed and the supporting
data, test reports no older than ten (10) years, have been re- evaluated.
All reports of re- testing shall bear the seal, signature and date of an engineer registered in the State of
Florida.
2. Any revision or change in the materials, use, or manufacture of the product or process shall automatically
be cause for termination, unless prior approval is granted for revisions or change.
3. Any unsatisfactory performance of this product or process or a change in Code provisions shall be grounds
for re- evaluation.
4. This acceptance shall not be used as an endorsement of any product for sales or advertising purposes.
5. The Notice of Acceptance number preceded by the words Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the Notice of Acceptance is
displayed, then it shall be done in its entirety.
6. Product approval drawings, where required for permit applications, shall be provided to the applicant by
the manufacturer or his distributors unless otherwise noted in the Notice of Acceptance. The prints need
not be re- sealed by an engineer.
7. Failure to comply with the Standard Conditions shall be cause for termination of the Approval.
This approval supersedes all previous approvals.
15
Raul Rodriguez
Product Control Supervisor
Application is hereby mode for the approval of the detailed statcurem ur ine plans and specifications herewith submitted for the build •
ing or other structure herein described. This application is made in compliance and conformity with the Building Ordinance of Miami
Shores Village, Florida, and nll provisions of the Laws of the State of Florida, all ordinances of Miami Shores Village and all rules and
regulations of the iuilding Division of Miami Shores Village shall be complied with, whether herein specified or not. A copy of approved
plans and specifications must be kept at building during progress of the work.
Owner's Name and Address W ��
Registered Architect and /or Engineer
Name and address of licensed contrtctorr e4P -4 "X
Location and 4' lc 3,l description of lot to be built on: A P f L" 771___5.' Q
Lot `¢ L % Block Q ' I Subdivisio_n.t£ . ! : '.Y: _
Street and Number where work is to be done `� G ` S TS e'
State work to be done and purpose of building (by floors) cr...
Estimated Total cost of improvements $.(,2. °, 0 0
Remarks
STATE OF FLORIDA,
COUNTY OF DADE. SS.
therein by him stated are true.
Permit No.._.21 1 d Date y �
Disapproved
(Signed)
G / a 1
MIAMI SHORES VILLAGE �,✓ /,‘8/f/p #P7
BUILDING INSPECTION DEPARTMENT
APPLICATION FOR BUILDING PERMIT
Date
Building Inspector
Signed)
Read, Sworn to and Subscribed
Notary Public, State of Flo
4
Date q9 J'S
_ No...4 .._ StreeLN t 1 .9j_
S P
1Avv.
a ' 1 07
P -
v e ,.) 4"- T - , t 7• 1....ec^r "Le∎ e S fo ■=1 c� a e r
3 (7 — c e-s
New Building
To be constructed of
• _..__ / �} and for no other purpose.
Kind of foundation Remodeling Addition Repairs ✓ !�e la ° No. of Stories / _ Co
Amount of Permit $..62 Q'
Zone cubage required Plan Cubage
Distance .to next nearest building Size of Building Lot
Maximum live load to be borne by each floor
I hereb submit all the pl s and specifications for said building. All notices with reference to the building and its construction may
be sent to.. O lo C 2,4S u u -Pt"►t .� ea , � -1 d 1 P J UJ t v< l.a t N1 i ►+w. i F ixa . ,33 15L2.--
The undersigned applicant for this building permit does hereby certify that he understands and accepts his obligations as an employer
of Labor under the Florida Workmen's Compensation Act, being Section 5966, Compiled General Laws of Florida, Permanent Supplement,
and has complied with the provisions thereof, and will require similar compliance from all contractors or sub - contractors employcd'by him
in the work to be performed under this permit; and will post or cause to be posted for inspection on the site of the work suchinubliv •
or notices as are required by the Act. The undersigned agrees to employ only such subcontragtors, on Ivor o , performea. uri •; _this
permit, as are licensed by Miami Shores Village.
0- SquW e.K
Before me, the undersigned authority, a notary public, duly authorized � t " o � administer oath and take acknowledgments, personally ap-
peared "W9 4 ,[ gh-e p ~-4 ��3 / tc2th t Ga 0 A%-r fr ...'
to me well known,
and who, being by me first duly sworn, upon oath deposes and says that he is the.2?0.6
of the above described construction, that he has carefully read the foregoing application, and thae did sign the same, and that all facts
v kiOTAR IC STATE OF FLORIDA AT LARGE
My Commission Expires _BA Y.. COMMLS�I.Q.N,EXP NOVA 1985
:BONDED THRU GENERAL INS. UNDERWRITERi
PLANNING BOARD DATE
Chairman Member
MIcrnber Member
Member .. ... — - ....._..._._ ...._....... Member
Council Approved Date Disapproved Date
NOTE: A charge of $1.00 will be made for making corrections or changes to this application after approval has been obtained from
the Plannir.. Board.
A re- inspection fee of 51.00 will be charged when such re- inspection is made necessary by improper notice for inspection or faulty
materials and /or workmanship.