WS-11-550Inspection Number: INSP - 157759 Permit Number: WS -3 -11 -550
Scheduled Inspection Date: May 09, 2011
Inspector: Bruhn, Norman
Owner: ROBBIN, DAN AND JOSEPHINE
Job Address: 810 NE 100 Street
Miami Shores, FL 33138-
Project: <NONE>
Contractor: FLORIDA HOME IMPROVEMENT
Building Department Comments
REPLACE 4 IMPACT WINDOWS
Passe
Failed
Correction
Needed
Re- Inspection
Fee
May 06, 2011
No Additional Inspections can be scheduled until
re- inspection fee is paid.
Inspection Worksheet
Miami Shores Village
10050 N.E. 2nd Avenue Miami Shores, FL
Phone: (305)795 -2204 Fax: (305)756 -8972
Inspector Comments
ec___
For Inspections please call: (305)762 -4949
Permit Type: Windows /Shutters
Inspection Type: Final
Work Classification: Window /Door Replacement
Phone Number
Parcel Number 1132060340060
Phone: (954)792 -4415
Page 8of21
10050 N.E.2nd Avenue, Miami Shores, Florida 33138
Tel: (305) 795.2204 Fax: (305) 756.8972
BUILDING Permit No. NS IV 0O PERMIT APPLICATION Master Permit No.
FBC0v%
Permit Type (circle): Building Electrical Plumbing Mechanical Roofing
Owner's Name (Fee Simple Titleholder) _ 0I36/A," Phone # JOS 76 - 3-21?
Owner' v r''s Address g/O E. /0 0
/ sr.
Cit /s) l 6,4-2 State — zip 5 3/36
Tenant/Lessee Name Phone #
Job Address (where the work is being done) gl 0 /0E- 109 sr
City Miami Shores Village County 1VIiami - Dade Zip 3 3/3
Is Building Historically Designated YES NO
Contractor's Company Name FLORIDA HOME IMPROVEMENT
Contractor's Address 4070 SW 30TH AVE
City HOLLYWOOD State FLORIDA Zip 33312
Qualifier WAYNE THOMAS BURNETT
Architect/Engineer's Name (if applicable) +, 4 SS)/b&i®
$ Value of Work For this Permit 10 , ?O (
Type of Work: ['Addition ['Alteration ❑
Deseribe Work: 6 4 1i Z Per
Total Fee Now Due $
(Continued on opposite side)
Miami Shores Village vf/LeCTUW53
�'. MAR 2 9 2011
Building Department
Phone # 954 - 792 -4415
BY:
Phone # qJ -/ -3 1-06630
❑ Repair/Replace ❑ Demolition
40 OS
Square Footage Of Work:
Submittal Fee $ Permit Fee $ `Z CCF $
Notary $ Training/Education Fee $ Technology Fee $
Scanning $ Radon $ Bond $
Code Enforcement $ Structural Plan Review. $
.---∎
5r 61 6 l
,• ",•
STEVE P. SLOZIK
<50 / , /x
1. , , P
;, «. ,,.. .,, :..
• -4,.-- ,,•1
EXPIRES: December 17, 2013
ommission Expires:" cl:;
Bonded Thru Notary Public Undenwrbers
r*** * * * *,w * *** * * * * * * * * * * *** **
* * * *,r ay * * * * * **** * *,* * ar
Bonding Company's Name (if applicable)
Bonding Company's Address
City State Zip
Mortgage Lender's Name (if applicable)
Mortgage Lender's Address
City State Zip
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has
commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating
construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS,
WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDTITONERS, ETC
OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all
applicable laws regulating construction and zoning.
"WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR
PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING,
CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF
COMMENCEMENT."
Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must
promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person
whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site
for the first inspection which occurs seven (7) days after the building permit is issued In the absence of such posted notice, the
inspection will be approved and a reinspectionJee will be charged
Signature
Owner or Agent
The foregoing instrument was acknowledged before me this 029'
day of Mafia"— , 20 /B , by DA) / - •og //►J ,
who is persona knowq to me or who has produced
As identification and who did take an oath.
NOTARY PUBLIC:
Sign:
Print:
My C
APPLICATION APPROVED BY:
Chc 10/14/03
Contractor
The foregoing instrument was acknow edged before me this 0
day of /))f72 il- , 20// , by tOPlyA)E- %
who is personally known to me or who has produced
as identification and who did take an oath.
NOTARY PUBLIC:
Sign:
Print:$ 5
My Commission E
* * * * * * * * * * * * * * * * * * * * * **
Plans Examiner
Engineer
Zoning
P. SMIZIK
MY COMMISSION It DD 947362
ig EXPIRES: December 17, 2013
• Bonded Thru N. Public Undenwrfters
(Certificate of Competency Holder)
State Certificate or Registration No. Certificate of Competency No.
***************************************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * **
FLORIDA BUILDING CODE & ASCE 7 -05
LOADS FOR COMPONENTS AND CLADDING
Mean
Roof
Height 10
0 -15ft
16 ft
18 ft
20 ft
22 ft
24 ft
26 ft
28 ft
30 ft
32 ft
34 ft
36 ft
38 ft
40 ft
42 ft
44 ft
46 ft
48 ft
50 ft
52 ft
54 ft
58 ft
60 ft
-50.
+46.5
-51.1
+47.1
-52.4
+48.3
-53.5
+49.4
INTERIOR Z
-51.1
+47.0
-52.2
+48.1
-54.6 -53.3
+50.4 +49.0
- 55.6 -54.3
+51.3 +49.9
-56.6 -55.2
+52.2 +50.8
57.5 -58.1
+53.0 +51.6
-58.3 -56.9
+53.8 +52.3
-59.1 -57.7
+54.5 +53.1
- 59.9 -58.4
+55.2 +53.7
-60.6 -59.1
+55.9 +54.4
-61.3 -59.8
+56.5 +55.0
-62.0 -60.5
+57.1 +55.6
-62.6 -61.1
+57.7 +56.2
-63.2 51.7
+58.3 +58.7
-63.8 -62.3
+58.8 +57.3
-84.4 52.8
+59.4 +57.8
-64.9 -63.4
+59.9 +58.3
-65.5 -63.9
+80.4 +58.8
-68.0 -64.4
+60.8 +59.2
-88.5 -64.9
+61.3 +59.7
-87.5 -65.8
+62.2 +60.6
-51.3
+47.1
0 2
-52.4
+48.1
.4 +48.8
-53.3
+49.0
-54.2
+49.8
55.1
+50.6
-55.9
+51.3
-56.7
+52.0
-57.4
+52.7
-58.1
+53.3
-58.7
+54.0
-59.4
+54.5
-60.0
+55.1
-60.6
+55.7
-61.2
+56.2
-61.7
+58.7
-622
+57.2
-62.8
+57.6
-63.3
+58.1
53.7
+58.5
-64.7
+59.4
.7
-52.6
+48.2
-53.5
+49.1
-54.3
+49.8
-55.1
+50.6
-55.9
+51.3
58.6
+51.9
-57.3
+52.5
-57.9
+53.1
-58.6
+53.7
-59.2
+54.3
-59.7
+54.8
-60.3
+55.3
-60.8
+55.8
-61.4
+56.3
-61.9
+58.8
-62.4
+57.2
-82.9
+57.7
-63.8
+58.5
-52.0
+47.6
-52.9
+48.4
-53.7
+49.2
-54.5
+49.9
-55.2
+50.6
55.9
+51.3
56.6
+51.9
-57.3
+52.5
-57.9
+53.0
-58.5
+53.6
-59.1
+54.1
-59.6
+54.6
50.1
+55.1
-60.7
+55.8
-61.2
+56.1
-61.7
+56.5
-82.1
+58.9
-63.0
+57.8
SSURES
-49.5
+45.3
-50.5
+46.3
-51.5
+47.1
-52.3
+47.9
-53.2
+48.7
-53.9
+49.4
-54.7
+50.1
-55.4
+50.7
-56.1
+51.3
-58.7
+51.9
-57.3
+52.5
-57.9
+53.0.
-58.5
+53.5
-59.0
+54.0
-59.6
+54.5
-60.1
+55.0
-60.6
+55.4
-81.0
+55.9
51.5
+56.3
52.4
+57.1
- Zone 4
40 45
-49.1
+44.9
.2 -45.9
+41.9
-46.5
+42.5
- 47.7
+43.6
- 48.7
+44.5
- 50.1 -49.7
+45.8 +45.4
-51.0 -50.6
+48.7 +48.3
-51.9 -51.5
+47.5 +47.1
-52.7 -52.3
+48.2 +47.8
-53.5 -53.1
+48.9 +48.5
-54.9 -54.5
+50.2 +49.8
-55.6 -55.1
+50.8 +50.4
-56.2 -55.8
+51.4 +51.0
58.8 56.4
+52.0 +51.5.
-57.4 -57.0
+52.5 +52.1
-58.0 -57.5
+53.0 +52.6
-58.5, ,58:1
+53.5 +53.1
- 59.0 -58.6
+54.0 +53.6
-59.5. 59.1':
+54.5 +54.0
-60.0 -59.6
+54.9 +54.5
-80.5 -60.1
+55.4 +54.9
- 81.0 -60.5
+55.8 +55.3
-61.9 -61.4
+58.6 +58.1
50
-45.5
+41.6
-482
+422
-47.3
+432
-48.4
+442
-49.4
+45.1
-50.3
+45.9
-51.1
+48.7
51.9
+47.4
-52.7
+48.1
-53.4
+48.8
-54.1
+49.4
-54.8
+50.0
-55.4
+50.6
-56.0
+51.1
56.6
+51.7
-57.1
+52.2
•57.7
+52.7
-58.2
+53.1
-58.7
+53.6
-592
+54.0
-59.6
+54.5
-60.1
+54.9
-61.0
+55.7
0 -15
Mean
Roof
Heigh
166
18 ft
20 ft
22 ft
24 ft
26 ft
28 ft
30 ft
32 ft
34 ft
38 ft
38 ft
40 ft
42 ft
44 ft
46 ft
486
60 ft
52 ft
54 ft
56 ft
60 ft
Tributary Area (Sq Ft)
10 15 20 25 30 35 40
45
50
-622 -59.8
+46.5 +452
.1
+47.1
-64.6
+48.3
-6&1
+49.4
-67.4
+50.4
-68.7
+51.3
-69.8
+522
-70.9
+53.0
-72.0
+53.8
-73.0
+54.5
-73.9
+552
-74.8
+55.9
-75.7
+56.5
-76.5
+57.1
-77.3
+57.7
-78.0
+58.3
-78.8
+58.8
-79.5
+59.4
-80.2
+59.9
-80.8
+60.4
-81.5
+60.8
-82.1
+61.3
-83.3
+622
-80.6
+45.9
-62.1
+47.0
-63.5
+48.1
-64.8
+49.0
-66.0
+49.9
-67.1
+50.8
-682
+51.6
-692
+52.3
-70.1
+53.1
-71.0
+53.7
-71.9
+54.4
-72.7
+55.0
-73.5
+55.6
-74.2
+562
-75.0
+56.7
-75.7
+57.3
-76.3
+57.8
-77.0
+58.3
-77.6
+58.8
-78.3
+592
-78.9
+59.7
-80.0
+60.6
-58.0
+44.4
-58.8
+45.0
-60.3
+46.1
-61.6
+47.1
-62.9
+48.1
-64.1
+49.0
-65.1
+49.8
-6662
+50.6
-67.1
+51.3
-68.1
+52.0
-88.9
+52.7
-69.8
+53.3
-70.6
+54.0
-71.3
+54.5
-72.1
+55.1
-72.8
+55.7
-73.5
+56.2
-74.1
+56.7
-74.8
+572
-75.4
+57.8
-76.0
+58.1
-76.6
+58.5
-77.7
+59.4
-58.7
+43.7
-57.5
+44.3
-58.9
+45,4
-602
+46.4
-61.4
+47.4
-62.6
+48.2
-63.6
+49♦1
-64:6
+49.8
+50.8
-66.5
+51.3
-87.3
+51.9
-68.1
+52.5
-68.9
+53.1
-69.7
+53.7
-70.4
+54.3
-71.1
+54.8
-71.8
+55.3
-72.4
+55.8
-73.0
+56.3
-73.8
+58.8
-742
+57.2
-74.8
+57.7
-75.9
+58.5
-55.6
+43.1
-56.3
+43.7
-57.8
+44.8
-59.0
+45.8
-602
+46.8
-61.4
+47.8
-62.4
+48.4
-63.4.
+492
-84.3
+49.9
-65.2
+50.6
-66.0
+51.3
-66.8
+51.9
-67.6
+52.5
-68.3
+53.0
-69.0
+53.6
-89.7
+54.1
-70.4
-71.0
+55.1
-71.6
+55.6
-722
+56.1
-72.8
-73.3
+57.8
-54.6
+42.7
-55.4
-56.8
-58.1
+45.3
-59.2
+46.3
-60.3
+47.1
+47.9
+48.7
-632
+49.4
-64.1
+50.1
-64.9
+51.3
+51.9
-672
+52.5
-67.9
+53.0
-68.5
+53.5
+54.0
-69.8
-70.4
-71.0
+55.4
-71.6
+55.9
-72.1
+56.3
-73.2
+57.1
-53.8
+42.3
-54.6
+42.9
-55.9
+43.9
-572
+44,9
-58.4
+45.8
-59.4
-60.4
-62.3
+48.9
-63.1
+49.6
-64.0
+502
-64.7
-65.5
+51.4
-66.2
+52.0
-66.9
+52.5
-67.5
+53.0
-68.8
+54.0
-69.9
+54.9
-70.5
-71.0
+55.8
-72.1
+56.6
-53.1
+41.9
-53.9
+42.5
-55.2
+43.6
-56.4
+44.5
-57.6
+45.4
-58.7
+46.3
-59.8
+47.1
-60.8
+47.8
-61.5
+48.5
-62.3
+492
-63.1
+49.8
-63.9
+50.4
-64.6
+51.0
-65.3
+51.5
-66.0
+52.1
+52.6
+53.1
+53.6
-68.5
+54.0
-69.0
+54.5
-69.6
+54.9
-70.1
+55.3
-71.1
-52.5
+41.6
-532
+422
+432
-55.8
+442
-56.9
+45.1
-58.0
+45.9
-58.9
+46.7
+47.4
-80.7
+48.1
-61.6
+48.8
-62.4
+49.4
-63.1
+50.0
-63.8
+50.6
-64.5
+51.1
-652
+51.7
-65.8
+522
-66.5
+52.7
-67.1
+53.1
-67.6
+53.6
-682
+54.0
-68.7
-69.3
+54.9
-70.3
+55.7
WIND VELOCITY=146 MPH
EXPOSURE 'C'
INSTRUCT/ONS FOR TABLE USE:
1. TABLES ARE INTENDED TO DEPICT THE 'WORST CASE PRESSURES. 'WORST CASE IS
DEFINED AS THE CRITICAL CONDMON OF ANY UNKNOWN VARIABLE AS DESCRIBED BELOW.
USE OF CRTRCAL CONDITIONS REQUIRED FOR USE WITH THESE TABLES.
2. FOR SITUATIONS THAT REQUIRE Kd=1.0, TABLE VALUES ARE UNDER-DESIGNED BY A
FACTOR OF 1.18. VERIFY Kd REQUIREMENTS WITH LOCAL MUNICIPALTIY PRIOR TO TABLE USE.
3. USE OF TABLES VALID ONLY FOR BUILDINGS LESS THAN 60' MEAN ROOF HEIGHT.
4. TABLES VALID FOR ALL ROOF SLOPES. REDUCTIONS FOR ROOF SLOPES LESS THAN 10°
SHALL BE PERFORMED BY AN ENGINEER AS A SITE SPECIFIC CONDITION.
5. IDENTIFY THE BUILDING MEAN (AVERAGE) ROOF HEIGHT. IF THE MEAN ROOF HEIGHT
CANNOT BE IDENTIFIED, USE THE PEAK ROOF HEIGHT.
6. ALWAYS ROUND UP ROOF HEIGHTS TO NEXT TABLE VALUE OR TO A CONSERVATIVE
ASSUMPTION.
7. CALCULATE THE TRIBUTARY AREA OF THE OPENING IN QUESTION (HEIGHT * WIDTH) OR
THE SPAN LENGTH (HEIGHT) MULTIPLIED BY AN EFFECTIVE WIDTH THAT NEED NOT BE LESS
THAN ONE-TFIIRD THE SPAN LENGTH (HEIGHT 2 / 3). USE THE AREA BETWEEN STRUCTURAL
OPENINGS ONLY- TFIIS INCLUDES AREAS BETWEEN STRUCTURAL MULLS. IF THE TRIBUTARY
AFtEA OF AN OPENING CANNOT BE IDENTIFIED, THE MOST CRITICAL (10 SQUARE FEET) SHALL
BE USED. ALWAYS ROUND TRIBUTARY AREA DOWN TO THE LESSER TABLE VALUE. FOR LARGER
TFUBUTARY AREAS THAN PUBLISHED, USE THE LARGEST PUBLISHED VALUE.
8. IDENTIFY THE ZONE OF THE OPENING AS INTERIOR (ZONE 4) OR EXTERIOR (ZONE 5) PER
THE FIGURE OR INFORMATION BY OTHERS. ANY QUESTIONABLE OPENING IS TO BE
CONSIDERED TFIE MORE CRITICAL (EXTERIOR) ZONE.
9. READ OFF POSMVE AND NEGATIVE PRESSURES FOR USE AS REQUIRED BY THE LOCAL
MUNICIPALITY IN ACCORDANCE WITH CODE.
GENERAL NOTES:
1. THESE CHARTS ARE NOT VALID AS A SITE-SPECIFIC DRAWING. THESE TABLES ARE ONLY
VALID WHEN SIGNED & RAISED SEALED BY FRANK L BENNARDO, P.E.
2. THIS SPECIFICATION IS INTENDED TO ILLUSTRATE DESIGN WIND PRESSURES AS LISTED.
USE OF THESE TABLES AND CORRESPONDING WIND VELOCITY, EXPOSURE, AND OTHER
COEFFICIENTS USTED HEREIN SHALL BE DICTATED AND VERIFIED BY THE GOVERNING
BUILDING DEPARTMENT AND PERMIT HOLDER. NO WARRANTY FOR APPUCABILITY OF TABLE
VALUE USE IS OFFERED HEREIN.
3. THIS SPECIFICATION IS NOT INTENDED TO OFFER ANY PRODUCT APPROVED
CERTIFICATION. REFER TO ANY SEPARATELY SUBMITTED TEST CRITERIA AND OTHER
APPROVALS FOR DESIGN & INSTALLATION INFORMATION AND APPLICABILITY OF THESE TABLE
VALUES WHICH IS TO BE VERIFIED BY OTHEFtS IN ACCORDANCE WITH GOVERNING CODES.
4. DESIGN IS BASED ON THE 3 SECOND GUST (WIND VELOCITY) FOR A CATEGORY II
(GENERAL RESIDENTIAL & COMMERCIAL CONSTRUCTION) USING AN IMPORTANCE FACTOR
1=1.0. THESE TABLES NOT FOR USE WITH ESSENTIAL FACILITIES OR ASSEMBLY OCCUPANCIES.
TOPOGRAPHIC FACTOR Kzt=1.0 FOR FLAT TERRAIN USE ONLY. THESE TABLES NOT VAUD FOR
HILLY TERRAIN. INTERNAL PRESSURE COEFFICIENT (GCp1=+/-0.18) ENCLOSED BUILDING ONLY.
VERIFY USE OF Kd=0.85 (DIRECTIONALITY FACTOR) WITH LOCAL BUILDING DEPARTMENT. HVHZ
= HIGH VELOCITY HURRICANE ZONE. TABLES ARE FOR WALLS AND VERTICAL SURFACES ONLY.
5. ADHERE TO ALL LOCAL IMPACT PROTECTION SYSTEM ORDINANCES.
6. NO CERTIFICATION IS OFFERED FOR THE INTEGRITY OF THE HOST STRUCTURE.
7. EXCEPT AS EXPRESSLY PROVIDED HEREIN, NO ADDITIONAL CERTIFICATIONS OR
AFFIRMATIONS ARE INTENDED.
a= 10% OF LEAST HORIZONTAL DIMENSION OR 40% OF MRH,
WHICHEVER IS SMALLER, BUT NOT LESS THAN 4% OF LEAST HORIZONTAL
DIMENSION OR 3FT (1m). USE ZONE 5 IF AT ALL IN QUESTION. CONSULT
AN ENGINEER FOR A MORE SPECIFIC INTERPRETATION IF REQUIRED.
WALL ZONE FIGURES
BASED ON Kd=0.85
SEE TABLE NOTES
FOR ALT Kd
PEAK ROOF
HEIGHT
MEAN
ROOF
HEIGHT
FtIC
tri
8
REMARKS
INIT ISSUE
REVISE FOR 07 FBC
DRVVN
CL
TSB
CHKD
FLB
FLB
DATE
04/19/06
THIS DOCUMENT IS TFIE PROPERTY OF FRANK L BENNARDO,
P.E AND SHALL NOT BE REPRODUCED DI WHOLE OR PART
WITHOUT WRITTEN CONSENT OF FRANK L BENNARDO, PE.
MARKINGS TO THIS DOCUMENT ARE NOT PERMUTED AND
INVALIDATE OUR CERTIFICATION,
2007 FLORIDA BUILDING CODE
DESIGN LOADS FOR
COMPONENTS & CLADDING
ENGINEERING
160 SW 12th AVENUE, #106
DEERFIELD BEACH, FL 33442
CERT OF AUTH 09885
MIAMI SHORES BUILDING DEPARTMENT .
PRODUCT APPROVAL SCHEDULE / COMPARISON CHART
Address: 810 NE 100 st, Miami Shores FL 33138 'Permit No.
Opening
ID
Window, Door
or Mullion
Product Acceptance #
Product Approval
Design Pressure
Opening Design
Pressure
Rough Opening
Size
Shutter Required
Yes / No
Mullion Required
Yes / No
Impact
Yes / No
1 2LR
WINDOW
FL130395
+ 70.0
-100.0
- 46.5
+ 62.2
73 x 611/2
NO
NO
YES
2 3LR
4.
FL13039.7
+ 75.0
-100.0
4,
.L
1041/2 x 611/2
4.
4.
4.
3 2LR
4.
FL13039.5
+ 80.0
-134.9
4
4.
43 5/8 x 61
4.
4.
4,
4 PW
4.
FL13045.5
+ 150.0
-150.0
4,
4,
35 x 611/2
4,
4.
4.
FHA - DIAGRAM SHEET
CUSTOMER NAME
fl Oib o +n
E •'. t::: ens <E< §KS °.y.:z �c'a.r.v,.x s�:'c eqt�:, ^r,
LEAD NUMBER
P4142.
TYPE OF PROPERTY
Hfroit
ROOF HEIGHT
I WO
MEASURING TECH
rn.t4-
FLOOR NUMBER
MEASURE DATE
3fZZ.�ri
TOTAL FLOORS
CCC -C- �
.�C�C..- ■� munimm C.. —I• ��C.■ ■■■. ! iaraw
C .. r .■■■;: �
■.. .■....CC. .. ...■. — maw __ man*
imummu..■..... mmimil 73 x 61 1/2 � OM 1041/2 x 611/2 �p
0 -100) FL1303 (75/ -100) FL13'39.7
...I•r " .\ 1■.�.....■■. .. m J A milmum iu m
•••.■ _'� �. � • mirmi /I.ri►�....��.i1 �IIII■HIP��■11.
; le��li
■�r ar► �C �► � ■.er........ � i.r ~ r■.�...■■� MOIMIN GEN
■/1r 1122111H 11 IMMIUB.■......■ .L VILTZEIMINIMMIIIIIIMMJELLAININIMIN
<AiffliPIf .i ....■.■..EMI ..■ T..rMI 43 5/8 x 611/2 ? r 7ii•..
Lil....
k\SML ....... ...
....TM (80/- 134.9) FL13039.51...r, mum \;E'�7.■.. ..�� ..;■M. �■..■rl�■
...■■ re. ... . ....o . v ■.■■..■
a ■ivv J � _r m:�rr
..mCla i .v .■ . ._.._■■ .. i� i...
r. �i�m IN N II nr.m .r I r CC . rl 4. -150 FL13045.5 1MI O
NM 1CC
■.■■MM..� MCC.ICC CC MM iiL / )
C MMiiimMiwumm
CC.......... ...1•.......MMIMMI...r..
.._ . .. ■r■..■.....■■.■....■■u..■...■
..I . CCCC .■■ ■■........r..■.■...■.....■
R: ..v... ■...■■.■.•�...■... ..■..■....ice ■..
■ ...I>�'��i�. ■......`....■.. .....■.�.....■N..m..V
.■.
....Ii" A i/.. ■.... . .. .■■.. .■.MM.■■�! EM
....IM NI■.■..■. .....
�/ �I.'
. .. - �.■..■..■ ..., .... r.�...■..... �■.f�
.. '...■■■....�....■
o.■ ..■. ■■ ummium
■ ■ ....... r,�►o.C.r.■C..■■ .�.. . C
�■.... CTS .........�■.0 ■..■.C�...■..._.... ■.0 CC
'■ ■.
. ■...;. ■.... ■.. ......■.... ■.........►
.��. .....
...�. ■.�.m ...C..■■■.
C C
� �.....■ ■.......■.. mo.
■■..om
' .�.................mu
C
......■.. .... ...- r..■■N ■■■..r ■I�.r.iw�■ ■
....r...■.■.■..
. ■. CCC ■��CC
■ a....... w....r... ......i....■.....■.mu..■..!...
s
.■■ mummilt?i�: . .. ■. ■:..... .......■■■mart._... ■'i.
■
. CCCClI CCCCC .CC�C7R ��ItCC��CA!
...my� dirt...■ ■■■C.mmmmu e mir mmumm ■.
mmom!'_ mli .... ■■memm ■.... ■.. ....■ ummumm.1•w7.
••• 1.�..C. ■..■!.m{ 7 wmC rir 7■■■.■...■I<71f" ..■ mar
■ .■... ■ ■.. ■ ■.� ... ..■■...■.
..
.......MMINMO rr.r.,ME ... ..■..rrt...r
.... lllilll.i.. i �T�1T� �� � * rs11■i ii�>•>•r... -.
C. rd1...IlI1 �.. 1■.r.■••■•■■I■
■ ■■.
1� ■..mumaualom i.i ■.■..!....r.. ■.
C CC CC .0 mmm>!t■■�m[ Im ....ai......
Q
Bi ■ ■. ■ ■C...■. ■..C...C.�1..`.
■N ■I I...■.m■.....■!!..
.. O ■ ..I,i�. i...■■.H�iO._ r.II.� ■ ■n■..■■...■
.....■..I!= mm...f lti mmm rr..II•• ....■■.....f�.
.■.■.■.■■u■ ��...�■!!uI�mfam.rourom mmum r?- .....■...r...■
■r..... unim mumumwmumm A emmammu..IEmfai..■■. ■.ru..m
.........I
....■....I li mommr.u..mmsamm m c m w
...■... .I ts'1=mma iTltlf namm...■. ■■.....■........ m ma
.■..... C.II. ■..... ■..._.....C.■....... .....�b>�.0
.......IuIIII LA1Ll!' i1 IL' S! L' 1.1 YM134iII1tIi11EfllllIMOa ®.■.....MI. Mr.,:VMIiW1Ill
.
■■.■ .> �Ea.....�.. wm.I
"CC•C■..■.... CCC�.■ .■...■. m ■■.■
C�■.....■�
■ . ■...■.......... i..... ii. . .._- ■_---.
mumummommmummmummummommommommommommommimmimmem
....■........minimum ....C............ mmum.......
Florida Building Code Online
Comm
Af'fairs
BCS Home Log In
Product Approval
USER: Pubic User
Product Anornval Menu a Product or And tan Search >SPROSERIEI > AppBeatfl DEW
FL #
Application Type
Code Version
Application Status
Comments
Archived
Address /Phone/Email
Authorized Signature
Technical Representative
Address /Phone /Email
Quality Assurance Representative
Address /Phone /Email
Category
Subcategory
Compliance Method
Certificate of Independence
User MO:seatbe I Hot Topics ( Submit Surcharge I Stats & Fatts I PubSCabons
http : / /www.floridabuilding.org/pr /pr app dtl.aspx?param=wGEVX...
Product Manufacturer PGT Industries
1070 Technology Drive
Nokomis, FL 34275
(941) 486-0100 Ext 22318
druark @pgtindustries.com
Robert park
bclark @pgtindustries.com
Robert Clark
1070 Technology Dr.
Venice, FL 34275
(941) 480-1600 Ext 21106
bdark @pgti ndustries.com
Florida Engineer or Architect Name who developed Luis Roberto Lomas
the Evaluation Report
Florida License PE -62514
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 12/31/2011
Validated By Steven M. Urich, PE
Validation Checklist - Hardcopy Received
039 .t !. 1
FBC Staff E BCIS Re Map ; kinks Search
Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report - Hardcopy Received
Referenced Standard and Year (of Standard) Year
AAMA/WDMA /CSA 101/I.S/A440 2005
ASTM E 1886 2005
ASTM E 1886 2002
ASTM E 1996 2002
ASTM E 1996 2005
TAS 201 1994
TAS 202 1994
TAS 203 1994
1 of 3 2/15/2011 2:33 PM
Florida Building Code Online
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Summary of Products
blip : / /www.floridabuilding.org/pr /pr app dtl.aspx?paramwGEVX...
Method 1 Option D
09/09/2009
09/10/2009
09/21/2009
10/13/2009
FL #
13039.1
Lhnits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: +60/ -65
Other: Rigid PVC From L.B. Plastics AAMA Certified
(LBP -1)
installation Instructions
FL13039 RO Il 08- 00838.odf
Verified By: Luis Roberto Lomas, P.E. 62514
Created by Independent Third Party: Yes
Evaluation Reports
FL13039 RO AE 511381.pdf
FL13039 RQ AE NOA 05- 1208.02 Dupont PVB.pdf
Created by Independent Third Party: Yes
13039.2 2LT HR2710M PVC Horizontal
Roller
21T HR2710M PVC Horizontal Roller 74 1/4" x 63 1/4"
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: +60/ -65
Other. Rigid PVC From LB. Plastics AAMA Certified
(LBP -1)
installation Instructions
FL13039 RO II 08-00839.pdf
Verified By: Luis Roberto Lomas, P.E. 62514
Created by Independent Third Party: Yes
Evaluation Reports
FL13039 RO AE 511382.pdt
FL13039 RO AE NOA 05 -1 08.02 Dupont PVB.pdf
Created by Independent Third Party: Yes
13039.3
Limits of Use
Approved for use In HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: +65/ -80
Other: Rigid PVC From LB. Plastics AAMA Certified
(LBP -1)
Installation Instructions
FL13039 RO n 08- 00840.pdf
Verified By: Luis Roberto Lomas, P.E. 62514
Created by Independent Third Party: Yes
Evaluation Reports
FL13039 RO AE 511383.pdf
FL13039 RO AE NOA Q5- 1208.02 Dupont PVB,pdf
FL13039 RO AE NOA 07- 1116.04 Dupont SGP.pdf
Created by Independent Third Party: Yes
13039.4
Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Model, Number or Name
Description
2LT HR2710 PVC Horizontal Roller 2LT HR2710 PVC Horizontal Roller 74 1/4" x 53 1/4"
2LT HR2710MI PVC Horizontal
Roller
2LT.HR2710MI PVC Horizontal Roller 74 1/4" x 63 1/4"
2LT HR271OM1 PVC Horizontal
Roller
2LT HR271OMI PVC Horizontal Roller 74 1/4" x 76"
Limits of Use
Approved for use In HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: +65/ -80
Other: Rigid PVC From L.B. Plastics AAMA Certified
(LBP -1)
Installation Instructions
FL13039 RO II 08-00841.pdf
Verified By: Luis Roberto Lomas, P.E. 62514
Created by Independent Third Party: Yes
Evaluation Reports
FL13039 RO AE 511384.pdf
FL13039 RO AE NOA 07- 1116.04 Dupont SGP.odf
Created by Independent Third Party: Yes
2LT HR2B10MI Horizontal Roller
2LT HR2810MI Horizontal Rolier 74 1/4" x 63 1/4
Installation Instructions
FL13039 RO 11 08- 00842.pdf
Verified By: Luis Roberto Lomas, P.E. 62514
Created by Independent Third Party: Yes
2 of 3 2/15/2011 2:33 PM
Design Pressure: +70/ -100
Other: Refer To Installation Instructions For Smaller Sizes
Design Pressure Ratings. Rigid PVC From LB. Plastics AAMA
Certified (LBP -1)
Evaluation Reports
F113039 RO AE 511385.odf
FL13039 RO AE NOA 07- 1116.04 Dupont SGP.odf
Created by Independent Third Party: Yes
13039.6
3LT HR2710MI Horizontal Roller
3LT HR2710MI Horizontal Roller 130" x 63"
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: +65/-65
Other: Rigid PVC From L.B. Plastics AAMA Certified
(LBP -1)
Installation Instructions
FL13039 RO U Q8- 00843,odf
Verified By: Luis Roberto Lomas, P.E. 62514
Created by Independent Third Party: Yes
Evaluation Reports
FL13039 RO AE 511386.00
FL13039 RO 9E NOA 05- 1208.02 Dupont PVB.Ddf
FU3039 RO AE NOA 07-1116.04 Dupont SGP.pdf
Created by Independent Third Party: Yes
13039.7
3LT HR2810MI PVC Horizontal
Roller
3LT HR2810MI PVC Horizontal Roller 130" x 63"
Limits of Use
Approved for use In HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: +75/ -100
Other: Rigid PVC From LB. Plastics AAMA Certified
(LBP -1)
Installation Instructions
FL13039 RO II 08- 00844.pdf
Verified By: Luis Roberto Lomas, P.E. 62514
Created by Independent Third Party: Yes
Evaluation Repot
FL13039 RO AE 511387.odf
FL13039 RO AE NOA 07-1116.04 Dupont SGP.pdf
Created by Independent Third Party: Yes
Florida. Building Code Online
DepaMment ofCatmmmu@y Alrees
Florida Beading Code Mine
Codes grid Standards
2555 Shuman' Oak Boulevard
Tallahassee, Fiches 32399 -2100
(850) 487-1824, Fax (850) 4144436
® 2000 -2010 The State of Florida. Al r6915S reserved.
Prloat v statem5et 1 Coavrlaht Statemeset i 1 h Snfnaare I Customer service Survey I Contact U4
Product Approval Accepts:
http: / /www.flaridabuilding.org/pr /pr app dtl.aspx?pararm= wGEVX...
*Al
3 of 3 2/15/2011 2:33 PM
L. Roberto Lomas P.E. Engineering Evaluation Report
1432 Woodford Rd.
Lewisville, NC 27012 Report No.: 511385
336 - 945 -9695
Manufacturer. PGT Industries
1070 Technology Drive
Nokomis, FL 34275
Product Line: 2LT HR2810MI PVC Horizontal Roller Window
Compliance:
The above mentioned product has been evaluated for compliance with the requirements of the Florida Department of
Community Affairs for Statewide Acceptance per Rule 96- 72.070 method 1(d). The product listed herein complies with
Requirements of the Florida Building Code including the HVHZ.
Supporting Technical Documentation:
1. Approval document: drawing number 08-00842, titled 2LT HR2810MI PVC Horizontal Roller Window, prepared,
signed and sealed by Luis Roberto Lomas P.E.
2. Test Report No. NCTL 210- 3638 -1, signed and sealed by Gerard J. Ferrara P.E.
National Certified Testing Laboratories, Orlando, FL.
TAS 201 -94 Large Missile Impact Test
TAS 202 -94 Uniform Static Air Pressure, +70.0 /- 100.0psf design pressure, l2psf water infiltration
TAS 203-94 Cyclic Pressure Loading, +80.01- 140.0psf design pressure
3. Test Report No. NCTL 210 - 3638 -1A, signed and sealed by Gerard J. Ferrara P.E.
National Certified Testing Laboratories, Orlando, FL
AAMANVDMA/CSA 101/L.S.21 M40-05
Design pressure: +70.0 /- 100.0psf
Water penetration resistance: 12psf
ASTM E 1886 - 02/-05 and ASTM E1996- 021-05
ASTM E 18861E 1996 Large Missile Impact Test, Level D, Wind Zone 4
ASTM E 18861E 1996 Cyclic Load Test, +80.0 /- 140.0psf design pressure
4. Anchor calculations, report number 511385 -1, prepared, signed and seated by Luis Roberto Lomas P.E.
5. Comparative analysis, report number 511385 -2, prepared, signed and sealed by Luis Roberto Lomas P.E.
Limitations and Conditions of use:
• Maximum design pressure: +70.0/- 100.0psf (See charts in approval document for smaller units ratings)
• Maximum overall size: 74 V44" x 63 '/"
• Maximum D.L.O.: 31 3 /4" x 5414"
• Units may be glazed with:
o 7/8" IGU consisting of outboard laminated Ifte consisting of 1/8" HS — 0.090" Sentry GlasPtus — 1/8"
HS — Air — inboard cite 1/8" Temp, or
o 5/16" monolithic laminated glass consisting of: 1/8" HS — 0.090" Sentry GlasPlus — 1/8" HS, per ASTM
El 300.
• This product is rated to be used in the HVHZ.
• This product is impact resistant and does not require impact protection in wind borne debris regions.
• Frame material to be extruded white rigid PVC .075" thick.
• Sash material to be extruded white rigid PVC .070" thick.
Installation:
• Units must be installed in accordance with approval document, 08 -00842
Certification of Independence:
Please note that I don't have nor will acquire a financial interest in any company manufacturing or distributing the
product(s) for which this report is being issued. Also, I don't have nor will acquire a financial interest in any other entity
Involved in the approval process of the listed product(s).
1 of 1
-NJ * • GEN q c .0'•
• *404$1,11f
: *
=1,1 •
TAT' t1F
3, ` 1, °R�0 4
/Jive N A i \% "
Luis R. Lomas, P.E.
FL No.: 62514
09/08/2009
CE$IIN PRESSURE RATING
IbiPACTRA7INQ
+ 70.0 PSF
- 100.0 PSF
UMW AND SMALL
MISSILE &+FACT
f4igpt
63.25"
MAX.
UNIT
HEIGHT
74.25" MAX. 'UNIT WIDTH
6" MAX. 10" MAX. O.C.
Msximam design pressure capacity that
ztrNs QDODS PVC NotlEw,tol Sliding Window
Sin and Tate DO Danttilt)
BDD
I;� iFZJT1L al �'ri� ��ai7
1111 11
IMS1111ILL: 111ZEI IMIlliLia7galIOW
LTL�liP:
ILLEICIIIIIGUILLEUCLIIIIIIIIIMIRLI 1 30 0 ILIUM
Eli 1400 Q:L1C mC J 1MIL JR+d7 JE.rF�ILiE7
4 2 . 0 i ] [Gd]L:7 iULU MEM C:EIELSMf:37i 7I 7CU
1 40 E sao LU
atrial 4111E11111133WiffITIMILI
a1I CI311 1=1C< 7La) so-0 EZEINZEILIIErcallialg.
SHEET NO.
1
2 — 4
5
59.25"
PANEL
HEIGHT
Number afaneparepor - .WWI?
DUtne Ofd wood se, :._. clrie SID TCIC saw
IzsrrI11111111E'UM
IIiKAM 'Z11111 7g"m
IBILUMMINEMI E1111
NEM EMMA 111131•111•111 NMI Ina
INEMIIIM MUM KM KM MIMI 11E11 KW
ILIA KM NMI If EMa MIN ILO KMIIIIrKM�ILti
1123 F�RJIr�II�sJwIIL1ITIDO OKEWNI
LILA ELM KM ILIMILUE 11111WWII KM MI
Kai NILAIIILII Enna Latili11101111111.111:111111110111 E•411111*.
(101
TABLE OF CONTENTS •
DESCRIPTION
ELEVATION AND GENERAL NOTES
INSTALLATION DETAILS
COMPONENTS AND GLAZING DETAILS
NOTES:
9)
REVISIONS
REV 1
DESCRIPTION
APPROVED
1) THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH
THE CURRENT FLORIDA BUILDING CODE INCLUDING THE I-IVHZ
2) WOOD FRAMING AND MASONRY OPENING TO BE DESIGNED AND ANCHORED TO
PROPERLY TRANSFER ALL LOADS TO STRUCTURE. FRAMING AND MASONRY
OPENING IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD.
3) CONTRACTOR 15 RESPONSIBLE FOR MAINTAINING STRUCTURAL INTEGRITY OF
WINDOW OPENING AND ALL. WOOD FRAMING AROUND WINDOW.
4) UNITS MUST BE GLAZED PER ASTM E1300 SEE SHEET 5 FOR APPROVED GLASS.
5) APPROVED IMPACT PROTECTIVE SYSTEM IS NOT REQUIRED FOR THIS PRODUCT IN
WIND —BORNE DEBRIS REGIONS.
6) SHIM AS REQUIRED AT EACH INSTALLATION ANCHOR WITH LOAD BEARING SHIM.
SHIM WHERE SPACE OF 1/16" OR GREATER OCCURS. MAXIMUM ALLOWABLE SHIM
STACK TO BE 1/4 ".
7 ) FOR INSTALLATION INTO WOOD FRAMING OR 2X BUCK USE #10 WOOD SCREW
WITH SUFFICIENT LENGTH TO ACHIEVE A 1 3/8" MINIMUM EMBEDMENT INTO
SUBSTRDETALS. ATE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION
8) FOR INSTALLATION INTO CONCRETE /MASONRY U 3/18" ITW TAPCO ITH
SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIM • SUBSTRATE.
LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS.
FOR ANCHORING INTO METAL FRAMING USE #10 TEK SELF TAPPING SCREWS WITH
SUFFICIENT LENGTH TO ACHIEVE A MINIMUM EMBEDMENT OF THREE THREADS PAST
THE FRAME THICKNESS. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND
INSTALLATION DETAILS.
10) ALL FASTENERS TO BE CORROSION RESISTANT.
INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR
MANUFACTURER'S INSTALLATION INSTRUCTIONS. AND ANCHORS SHALL NOT BE
USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH
SPECIFIED BELOW:
A. WOOD — MINIMUM SPECIFIC GRAVITY OF G=0.42
B. CONCRETE — MINIMUM COMPRESSIVE STRENGTH OF 3,200 PSI.
C. MASONRY — STRENGTH CONFORMANCE TO ASTM C -90, GRADE N, TYPE 1 (OR
GREATER).
D. METAL FRAMING — 18GA (.080) MINIMUM THICKNESS
12) ALLOWABLE STRESS INCREASE OF 1/3 WAS NOT USED IN THE DESIGN OF THE
PRODUCT SHOWN HEREIN. WIND LOAD DURATION FACTOR Cd =1.6 WAS USED FOR
W000 ANCHOR CALCULATIONS.
13) FRAME AND SASH MATERIAL: RIGID PVC
11)
PGT INDUSTRIES
1070 TECHNOLOGY DRIVE
NOKOMIS, FL 34275
2LT HR2810MI PVC HORIZONTAL ROLLER WINDOW
74 1/4" x 63 1/4"
ELEVATION AND NOTES
DRAWN:
R.L.
1 200 N0.
08 -00842
r-v
WALE NTS j"ATE 09/02/09 Is" T1 OF 5
1.25"
MIN. EMB.
CONCRETE/
MASONRY
BY OTHERS
1X BUCK PT
EXTERIOR
2.50" MIN.
r EDGE DISTANCE
•
HEAD & JAMB
CONCRNRYFLANGE INSTALLATION
HAD SHO WL JAMES SIMILAR
1X BUCK PT
1.25
MIN. EMB.
f �d
2.50" MIN.
EDGE DISTANCE
;
INTERIOR
.25" MAX. j
SHIM SPACE
SILL
CONCRETMJASONRY FLANGE!NSTALIATION
RIGID FILLER
3/16° TAPCON
3/16 TAPCON
RIGID FILLER
.25 MAX.
f SHIM SPACE
CONCRETE/
MASONRY
BY OTHERS
PERIMETER
SEAL
BY OTHERS
EXTERIOR
Nir
HEAD & JAMB
WOOD FRAMING OR2X BIIOK FLANGE INSTALLATION
HEAD SHOWN JAMBS SMEAR
EXTERIOR
WOOD FRAMING
OR 2X BUCK
BY OTHERS
PERIMETER
SEAL
BY OTHERS
SILL
WOOD FRAMING OR EX BUCK FLANGE
INSTALLATION
T
INTERIOR
Q74 INTERIOR
1 3/8°
MIN. EMB.
.25" MAX. , J
SHIM SPACE
RIGID FILLER
#10 WOOD
SCREW
f10 WOOD
SCREW
RIGID FILLER
.25" MAX.
SHIM SPACE
1 3/8"
MIN. EMB.
REVISIONS
REV
DESCRIPTION
RAZE
MPROVEO
METAL STUD
16GA MIN
BY OTHERS
EXTERIOR INTERIOR
HEAD & JAMB
METAL FRAMING FLANGE INSTALLATION
HEAD SHOWN JAMBS SIMILAR
METAL FRAMING
16GA MIN
BY OTHERS
#10 TEK
SCREW
RIGID FILLER
EXTERIOR , ; - INTERIOR
PGT INDUSTRIES
1070 TECHNOLOGY DRIVE
NOKOMIS, FL 34275
2LT HR2810MI PVC HORIZONTAL ROLLER WINDOW
74 1/4" x 63 1/4"
FLANGE INSTALLATION DETAILS
DRAWN.
R.L.
I D7TO ND.
08-00842
IREI
NTS !DATE 09/02/09 I mIEET2 OF 5
SILL
METAL FRAMING FLANLEWSTALLATION
.25 MAX.
SHIM SPACE
#10 TEK
SCREW
RIGID FILLER
.25 MAX.
SHIM SPACE
CONCRETE/
MASONRY
BY OTHERS
1X BUCK PT
2.50" MIN.
r - EDGE DISTANCE
EXTERIOR
IX BUCK PT
1.25"
MIN. EMS.
I---
HEAD & JAMB
CONCRETMIA$ONRY BOX FRAME INSTALLATION
HEAD SHOWA. JAMBS SIMILAR
2.50° MIN.
EDGE DISTANCE
.25° MAX. j
SHIM SPACE
RIGID FILLER
3/16" TAPCON
3/16" TAPCON
RIGID FILLER
.25" MAX.
SHIM SPACE
SILL
CONCRETE/MASON 4YBOX FRAME INSTALLAT
CONCRETE/
MASONRY
BY OTHERS
WOOD FRAMING
OR 2X BUCK
BY OTHERS
EXTERIOR
Jr
HEAD & JAMB
WOOD FRAMtNG OR EX BUCK BOX FRAME INSTALLATION
HEAD SHOWN, JAMBS SIMILAR
EXTERIOR
WOOD FRAMING
OR 2X BUCK
BY OTHERS
INTERIOR
anf
SILL
WOOD FRAMING OR EX BUCK BOX FRAME
INSTALLATION
T
INTERIOR
1 3/8"
MN. EMS.
25" MAX. J
SHIM SPACE
RIGID FILLER
#10 WOOD
SCREW
#10 W000
SCREW
RIGID FILLER
.25" MAX.
SHIM SPACE
1 3/8"
MIN. EMB.
REVISIONS
DESCRIPTION
DATE I APPROVED
METAL STUD
160A MIN
BY OTHERS
EXTERIOR
EXTERIOR
METAL FRAMING
16GA MIN
BY OTHERS
INTERIOR
HEAD & JAMB
METAL FRAMING BOX FRAME INSTALLATION
HEAD SHOWN, JAMBS SIMILAR
SILL
METAL FRAMING BOX FRAME INSTALLATION
PGT INDUSTRIES
1070 TECHNOLOGY DRIVE
NOKOMIS, FL 34275
2LT HR2810MI PVC HORIZONTAL ROLLER WINDOW
74 1/4" x 63 1/4"
BOX FRAME INSTALLATION DETAILS
DRAWN: DW NO. R
R.L 08 -00842 j E.V
-
SPAI NTS ( DATE 09/02/09 PREET3 OF 5
INTERIOR
.25" MAX.
SHIM SPACE
RIGID FILLER
}0 TEK
CREW
#10 TEK
SCREW
RIGID FILLER
.25" MAX.
SHIM SPACE
9
CONCRETE/
MASONRY
BY OTHERS
1x BUCK PT
EXTERIOR
1X BUCK PT
_l.
1.25"
MIN. EMB.
2.50" MIN.
r EDGE DISTANCE
3/16" TAPCON
INTERIOR
HEAD & JAMB
CONCRETE/MASONRYFIN INSTALLATION
HEAD SHOWN, JAMES SIMIAR
.
I 2.50" MIN.
EDGE DISTANCE
SILL
CONCRETE/MASONRY FIN INSTALLATION
1.25"
MIN. EMB.
.25" MAX. J
SHIM SPACE
RIGID FILLER
c
.25" MAX.
{ SPACE
WOOD FRAMING
OR 2X BUCK
BY OTHERS
SHEATING
BY OTHERS
EXTERIOR
WOOD FRAMING
OR 2X BUCK
BY OTHERS
SHEATING
CONCRETE / BY OTHERS
MASONRY
BY OTHERS
mi
n ,
�"�
EXTERIOR INTERIOR
H''+ &JAMB
WOOD FRAMING OR EX !LICK FAY INSTALLATION
HEAD SHOWN JAMBS SIMILAR
T
#10 WOOD
SCREW
INTERIOR
1.38"
MIN. DAB.
.25 MAX. j
SHIM SPACE
RIGID FILLER
#10 WOOD
SCREW
RIGID FILLER
SILL
WOOD FRAMING OR EX SUCK FIN INSTALLATION
.25" MAX.
} - SHIM SPACE
1.38"
IN. EMB.
REVISIONS
REV
DESCRIPTION I DATE I APPROVED
EXTERIOR
METAL STUD
16GA MIN
BY OTHERS
HEAD & JAMB
METAL FRAMING FIN INSTALLATION
HEAD SHOWN, JAMES SIMILAR
METAL FRAMING
16GA MIN
BY OTHERS ----
SILL
INTERIOR
PGT INDUSTRIES
1070 TECHNOLOGY DRIVE
NOKOMIS, FL 34275
21T HR281OMI PVC HORIZONTAL ROLLER WINDOW
74 1/4" x 63 1/4"
FIN INSTALLATION DETAILS
DRAWN:
R.L.
I DWG ND.
08 -00842
SCALE NTS (DATE 09/02/09 1 15M17 4 OF 5
RIGID FILLER
#10 TEK
SCREW
METAL FRAMING 1?N INSTALLATION
.25" MAX.
SHIM SPACE
#10 TEK
SCREW
RIGID FILLER
.25" MAX.
SHIM SPACE
3.06"
.33"
SIKAFLEX .
552
2.196" - I -
1 1.13"
HEAD & JAMB (8301)
VINYL PVC .075' THICK
1.83 ---
n
GLASS TYPEA
1.476"
INNER INTERLOCK RAIL (8308)
VINYL PVC .07° THICK
I I �r
_ ! I v ll
5" 1 1 fl .5"
t f
SILL (8303)
VINYL PVC .075" THICK
.224"
2.2"
.313"
.125" HS .125 HS
.090" SENTRY .090" SENTRY
GLASPLUS GLASPLUS
.125" HS .125" HS
EXTERIOR 111 INTERIOR EXTERIOR
SIKAFLEX
552
1.83
1.276"
GLASS TYPE 8
4.455"
1.476"
1.295
345"
HS INSERT
(NC -RW-PR -118)
0063 -TS ALUMINUM .tom°THICK
1.476"
.83" I
}
OUTER INTERLOCK RAIL (8307) HORIZONTAL SASH (830j)
VINYL PVC .07" THICK VINYL PVC .07"THICK
-[ 1.27" r-
1.92"
L
VERTICAL STIFFENER
(NC-RW-PR-112)
ALUMINUM 6063 -T 6.08" T HICK
1.476"
VERTICAL SASH (8306)
VINYL PVC .07° THICK
H 2.55"
1.395"
I 5/16' PLAIN BEAD (8321)
VINYL PVC .06" THICK
1.052"
.265"
X1.78"1".-
TT
SASH INSERT (NC -RW-PR -117)
6053-T5 ALUMINUM .085" THICK
- --1.69" --{
1
I r.14"
REVSICOTS
REV
DESCRIPTION
I DATE I APPROVED
-1 1.04 I
.8"
STIFFENER (STIOO7B)
160A GALVANIZED STEEL
.985"
7/8" LIFT BEAD (8324)
VINYL PVC .08 "THICK
.265"
.985"
SILL TRACK 7/8" PLAIN BEAD (8325)
ALUMINUM 6053-T5 VINYL. PVC .08" 7160K
PGT INDUSTRIES
1070 TECHNOLOGY DRIVE
NOKOMIS, FL 34275
2LT HR281OM1 PVC HORIZONTAL ROLLER WINDOW
74 1/4" x 63 1 /4"
COMPONENTS AND GLAZING DETAILS
R.L
MO ND.
08 -00842
scALE NTS I DATE 09/02/09 I5 OF 5
FIN ADAPTER
VINYL PVC .062° THICK
5/16" LIFT BEAD (8320)
VINYL PVC.OS°
1 1.279° 1-
15" RI GID FILLER
VINYL PVC .tS"THICK
.797
LJ
15 RIGID FILLER
VINYL PVC .ts"THICK
Florida Building Code Online
Product Approval
USER: Pubic User
Product Ag±rovsl Mara= > Pn,duct or_Aagicetbn Bearch > Aooitatbn List > AppEcatlon DetaM
FL
Application Type
Code Version
Application Status
Comments
Archived
Product Manufacturer
Address /Phone /Email
Authorized Signature
Technical Representative
Address/Phone /Email
Quality Assurance Representative
Address/Phone /Email
Category
Subcategory
Compliance Method
Florida Engineer or Architect Name who developed
the Evaluation Report
Florida License
Quality Assurance Entity
Quality Assurance Contract Expiration Date
Validated By
Certificate of Independence
Referenced Standard and Year (of Standard)
http: / /www.floridabuildil .orgJpr /pr app dtl.aspx?param wGEVX...
Mot Topics f Submit Surcharge i State & Facts ; Pubbca
PGT Industries
1070 Technology Drive
Nokomis, FL 34275
(941) 486-0100 Ext 22318
druark pgtindustries.com
Robert dark
bdark@pgtindustries.com
Robert Clark
1070 Technology Dr.
Venice, FL 34275
(941) 480-1600 Ext21106
bdark@pgtindustries.com
Luis Roberto Lomas
FL13039 RO CQI 511381.pdf
Standard
AAMA/WDMA /CSA 101/I.5/A440
ASTM E 1886
ASTM E 1886
ASTM E 1996
ASTM E 1996
TAS 201
TAS 202
TAS 203
Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report - Hardcopy Received
PE -62514
Keystone Certifications, Inc.
12/31/2011
Steven M. Urich, PE
Valklation Checklist - Hardcopy Received
Year
2005
2005
2002
2002
2005
1994
1994
1994
1 of 3 2/15/2011 2:08 PM
Florida Building Code Online
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Summ
of Products
http://www.floridabuilding.org/pr/pr
Method 1 Option D
09/09/2009
09/10/2009
09/21/2009
10/13/2009
rY
FL #
13039.1
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant Yes
Design Pressure: +60/ -65
Other: Rigid PVC From LB. Plastics AAMA Certified
(LBP -1)
Installation Instructions
FL13039 RO II 08-00838.odf
Verified By: Luis Roberto Lomas, P.E. 62514
Created by Independent Third Party: Yes
Evaluation Reports
FL13039 RO AE 511381.0df
FL13039 RO AE NOA 05- 1208.02 Dupont PVB.ndf
Created by Independent Third Party: Yes
13039.2
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: +60/ -65
Other: Rigid PVC From L.B. Plastics AAMA Certified
(LBP-1)
Installation Instructions
FL13039 RO II 08- 00839.odf
Verified By: Luis Roberto Lomas, P.E. 62514
Created by Independent Third Party: Yes
Evaluation Reports
pi Qg OA E
FL130 9 RO AE NOA 05- 1208.02 Dupont PVB.pdf
Created by Independent Third Party: Yes
13039.3
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: +65/-80
Other: Rigid PVC From LB. Plastics AAMA Certified
(LBP -1)
Installation Instructions
FL13039 RO II 08-00840.pdf
Verified By: Luis Roberto Lomas, P.E. 62514
Created by Independent Third Party: Yes
Evaluation Reports
FL13039 RO AE 511383.odf
FL13039 RO AE NOA 05- 1208.02 Dupont PVB.ndf
F113039 RO AE NOA 07- 1116.04 Dupont SGP.odf
Created by Independent Third Party: Yes
13039.4
13039.5
Model, Number or Name
Description
2LT HR2710 PVC Horizontal Roller 2LT HR2710 PVC Horizontal Roller 74 1/4" x 53 1/4"
2LT HR2710M PVC Horizontal
Roller
2LT HR2710M PVC Horizontal Roller 74 1/4" x 63 1/4"
2LT HR2710MI PVC Horizontal
Roller
2LT HR271OMI PVC Horizontal Roller 74 1/4" x 63 1/4"
2LT HR271OMI PVC Horizontal
Roller
2LT HR271OMI PVC Horizontal Roller 74 1/4" x 76"
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: +65/ -80
Other: Rigid PVC From LB. Plastics AAMA Certified
(LBP -1)
Installation Instructions
FL13039 RO II 08- 00841.odf
Verified By: LuIs Roberto Lomas, P.E. 62514
Created by Independent Third Party: Yes
Evaluation Reports
FL13039 RO AE 511384.pdt
FL13039 RO AE NOA 07-1116.04 Dupont SGP.odf
Created by Independent Third Party: Yes
2LT HR2810MI Horizontal Roller
2LT HR2810MI Horizontal Roller 74 1/4" x 63 1/4"
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Installation Instructions
FL13039 RO 11 08- 00842.odf
Verified By: Luis Roberto Lomas, P.E. 62514
Created by Independent Third Party: Yes
2 of 3 2/15/2011 2:08 PM
Design Pressure: +70/ -100
Other: Refer To Installation Instructions For Smaller Sizes
Design Pressure Ratings. Rigid PVC From L.B. Plastics AAMA
Certified (LBP -1)
Evaluation Reports
FL13039 RO AE 511385.odf
FL13039 RO AE NOA 07-1116.04 Dupont SGP,odf
Created by Independent Third Party: Yes
13039.6 1 3LT HR2710MI Horizontal Roller
3LT HR271OMI Horizontal Roller 130" x 63"
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: +65/ -65
Other. Rigid PVC From L.B. Plastics AAMA Certified
(LBP -1)
Installation Instructions
FL13039 RO II 0$-00843.odf
Verified By: Luis Roberto Lomas, P.E. 62514
Created by Independent Third Party: Yes
Evaluation Reports
FL13039 RO AE 511386.od(
FL13039 RO AE NOA 05- 1208.02 Dupont PVB.pdf
FL13039 RO AE NOA 07- 1116.04 Dupont SGP.pdf
Created by Independent Third Party: Yes
13039.7
3LT HR2810ML PVC Horizontal
Roller
3LT HR2810MI PVC Horizontal Roller 130" x 63°
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: +75/ -100
Other. Rigid PVC From LB. Plastics AAMA Certified
(LBP -1)
Installation Instructions
FL13039 RO II 08- 00844.pdf
Verified By: Luis Roberto Lomas, P.E. 62514
Created by Independent Third Party: Yes
Evaluation Reports
FL13039 RO AE 511387.odf
FL13039 RO AE NOA 07- 1116.04 Dupont SGP.pdf
Created by Independent Third Party: Yes
Florida Building Code Online
http : / /www.floridabuilding.org/pr /pr app dtl.aspx?param wGEVX...
Department ofCommtott<yAriaha
Fkakla Dalkfing Coda Online
Codas and Standards
2555 Shwn rd Oak Boulevard
Tallahassee, Florida 32399.2100
(850)487-1824, Fax (850) 414 -8436
0) 2000 -2010 The State of Florida. An rights reserved
PtWacv Statement 1 galatdahLifalattlea 1 Arras e8 , Statement 1 pluo - Software !Customer SpMrn Survey !Conant !14
Product Approval Accepts:
etrttr itvke
1Cr+ed
3 of 3 2/1512011 2:08 PM
L. Roberto Lomas P.E. Engineering Evaluation Report
1432 Woodford Rd.
Lewisville, NC 27012 Report No.: 511387
336 - 945.9695
Manufacturer: PGT Industries
1070 Technology Drive
Nokomis, FL 34275
Product Line: 3LT HR2810MI PVC Horizontal Roller Window
Compliance:
The above mentioned product has been evaluated for compliance with the requirements of the Florida Department of
Community Affairs for Statewide Acceptance per Rule 9B- 72.070 method 1(d). The product listed herein complies with
Requirements of the Florida Building Code including the HVHZ.
Supporting Technical Documentation:
1. Approval document drawing number 08-00844, titled 3LT HR2810MI PVC Horizontal Roller Window, prepared,
signed and sealed by Luis Roberto Lomas P.E.
2. Test Report No. NCTL 210 - 3641 -3, signed and sealed by Gerard J. Ferrara P.E.
National Certified Testing Laboratories, Orlando, FL.
TAS 201 -94 Large Missile Impact Test
TAS 202 -94 Uniform Static Air Pressure, +75.0 /- 100.0psf design pressure; 12psf water infiltration
TAS 203 -94 Cyclic Pressure Loading, ±75.0/- 100.0psf design pressure
3. Test Report No. NCTL 210 - 3641 -3A, signed and sealed by Gerard J. Ferrara P.E.
National Certified Testing Laboratories, Orlando, FL
AAMA/WDMA/CSA 10111.S.2/ A440-05
Design pressure: +75.0/- 100.0psf
Water penetration resistance: 12psf
ASTM E 1886 - 02/-05 and ASTM E1996-02/ -05
ASTM E 18861E 1996 Large Missile Impact Test, Level D, Wind Zone 4
ASTM E 18861E 1996 Cyclic Load Test, +75.01- 100.0psf design pressure
4. Anchor calculations, report number 511387 -1, prepared, signed and sealed by Luis Roberto Lomas P.E.
Limitations and Conditions of use:
• Maximum design pressure:
• Maximum overall size:
• Maximum Active sash size:
• Maximum Active sash D.L.O.:
• Maximum Fixed sash size:
• Maximum Fixed sash D.LO.:
• Units may be glazed with:
+75.0 /- 100.0psf
130° x 63"
36 1/4" x 59 9/16"
32 3/8 "x54 1/4°
57 7/8" x 59 3/8"
51 1/4" x 541/4°
o 7/8" IGU consisting of outboard laminated lite consisting of: 118" HS — 0.090" Sentry GlasPlus —1 /8"
HS — Air — inboard Ilte 1/8" Temp
o 5116" monolithic laminated glass consisting of: 1/8" HS — 0.090" Sentry GlasPius —1/8" HS
• This product is rated to be used in the HVHZ.
• This product is impact resistant and does not require impact protection in wind bome debris regions.
• Frame material to be extruded white rigid PVC .075" thick.
• Sash material to be extruded white rigid PVC .070" thick
installation:
• Units must be installed in accordance with approval document, 08 -00844
Certification of independence:
Please note that I don't have nor will acquire a financial interest in any company
manufacturing or distributing the product(s) for which this report is being issued. Also, I
don't have nor will acquire a financial interest in any other entity involved in the approval
process of the listed product(s).
1 of 1
�� .01 1111tt
.% 5 R. L0
•\ • • ,r
Z*' D 5 :
7."'-'73 TAT 67
' 4',' / ONA%.� i k1\`'�
Luis R. Lomas, P.E.
FL No.: 62514
09/09/2009
6" MAX.
1
I
12 3/4"
MAX.
O.0 TYP
T
6" MAX.
TYP.
6" MAX.
TYP,
0
36 1/4" ACTIVE
SASH WIDTH
32 3/8"
D.LO.• WIDTH
8" MAX.
O.C. TYP.
130" MAX. O.A. WIDTH
57 7/8" FIXED SASH WIDTH
51 3/4" D.L.O. WIDTH
HR2810M1 PVC HORIZONTAL ROLLER WIN
EXTERIOR VIEW
DESIGN PRESSURE RATING IMPACT RATING
+ 75.0 PSF LARGE AND SMALL
- 100.0 PSF MASSILE IMPACT
TABLE OF CONTENTS
SHEET NO.
1
2
3
4
6 MAX.
TYP. 1_
DESCRIPTION
ELEVATION, ANCHORING AND NOTES
BOX FRAME INSTALLATION DETAILS
FLANGE FRAME INSTALLATION DETAILS
COMPONENTS AND GLAZING DETAILS
REVISIONS
REV I
DESCRIPTION I DATE I APPROVED
PGT INDUSTRIES
1070 TECHNOLOGY DRIVE
NOKOMIS, FL 34275
3LT HR2810MI PVC HORIZONTAL ROLLER WINDOW
130" x 83"
ELEVATION, ANCHORING AND NOTES
CRON:
TJH
I DNS NO.
08 -00844
1�
SCE NTS I° 09/02/09 I OF 4
01111i /
Nao
4 . A T k " OF ; i7-
NOTES:
1) THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO
COMPLY WITH REQUIREMENTS OF THE FLORIDA BUILDING CODE.
2) WOOD FRAMING AND MASONRY OPENING TO BE DESIGNED AND
ANCHORED TO PROPERLY TRANSFER ALL LOADS TO STRUCTURE.
FRAMING AND MASONRY OPENING IS THE RESPONSIBILITY OF THE
ARCHITECT OR ENGINEER OF RECORD.
3) ALLOWABLE STRESS INCREASE OF 1/3 WAS NOT USED IN THE
DESIGN OF THE PRODUCT SFIOWN HEREIN. WIND LOAD DURATION
FACTOR Cd =1.6 WAS USED FOR WOOD ANCHOR CALCULATIONS.
4) FRAME AND SASH MATERIAL PVC
5) UNITS MUST BE GLAZED WITH 7/8° IGU LAMINATED GLASS OR
11/32" SINGLE LAMINATED GLASS PER ASTM £1300. SEE SHEET 4
FOR APPROVED GLASS TYPES.
6) APPROVED IMPACT PROTECTIVE SYSTEM IS NOT REOUIREQ FOR THIS
PRODUCT IN WIND BORNE DEBRIS REGIONS.
/16" 7) SHIM AS REQUIRED AT EACH INSTALLATION ANCHOR WITH LOAD
SASH BEARING SHIM. SHIM WHERE SPACE OF 1/16" OR GREATER OCCURS.
MAXIMUM ALLOWABLE SHIM STACK
HT 63" 8) FOR ANCHORING INTO MASON r E 3/16" ITW TAPCON H
MAX. OA. SUFFICIENT LENGTH TO ACHIEVE MENT INTO
HEIGHT SUBSTRATE WITH 2 5/8" MINIMUM EDGE DISTANCE. LOCATE ANCHORS
AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS.
9) FOR ANCHORING INTO WOOD FRAMING OR 2X BUCK USE #10 WOOD
SCREW WITH SUFFICIENT LENGTH TO ACHIEVE A 1 3/8° MINIMUM
EMBEDMENT INTO SUBSTRATE. LOCATE ANCHORS AS SHOWN IN
ELEVATIONS AND INSTALLATION DETAILS.
10) FOR ANCHORING INTO 16GA. MINIMUM STEEL STUD USE #10 TEI<
SCREW WITH SUFFICIENT LENGTH TO ACHIEVE 3— THREAD PITCHES
MINIMUM BEHOND SUBSTRATE. LOCATE ANCHORS AS SHOWN IN
ELEVATIONS AND INSTALLATION DETAILS.
11) ALL FASTENERS TO BE CORROSION RESISTANT.
12) INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH
ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS. AND ANCHORS
SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN TI<
MINIMUM STRENGTH SPECIFIED BELOW:
A. WOOD — MINIMUM SPECIFIC GRAVITY OF 0 =0.42
B. CONCRETE — MINIMUM COMPRESSIVE STRENGTH OF 3,200 P51.
C. MASONRY — STRENGTH CONFORMANCE TO ASTM C -90, GRADE N, YPE
1 (OR GREATER).
D. METAL FRAMING — 16GA. (.060") MINIMUM THICKNESS.
2 5/8" MIN.
EDGE DIST.
4
1 1/4" MIN.
EMBEDMENT
Am1Uaru --
APPROVED SEALANT
BY OTHERS
} 1/4" MAX.
SHIM
APPROVED SEALANT
BY OTHERS
1/4" MAX.
} SHIM
1 1/4" MIN.
EMBEDMENT
1 3/8" MIN.
EMBEDMENT
1X BUCK BY OTHERS,
1X BUCK TO BE
PROPERLY SECURED 1/4" MAX. 2
RIGID FILLER SHIM
3/16" ITW
TAPCON
i r EXTERIOR I INTERIOR
HEAD INSTALLATION DETAIL
1X BUCK MASONRY/CONCRETE
HEAD SHOWN JAMB IS SIMILAR
2 5/8" MIN.
EDGE DIST.
SILL INSTALLATION DETAIL
IX BUCK MASONRY/CONCRETE
f MASONRY /CONCRETE
BY OTHERS
APPROVED SEALANT
BY OTHERS
RIGID FILLER
1X BUCK BY OTHERS,
1X BUCK TO BE
PROPERLY SECURED
EXTERIOR X N 1 Il INTERIOR
HEAD INSTALLATION DETAIL
2XBUCKANOODFRAMING
HEAD SHOWN JAMB IS SIMILAR
EXTERIOR N $ $ INTERIOR
1111111
SHIM
2X BUCK /W000 FRAMING
BY OTHERS, 2X BUCK
TO BE PROPERLY SECURED
APPROVED SEALANT
BY OTHERS
SILL INSTALLATION DETAIL
SX BUGKANOOD FRAMING
T
RIGID FILLER
2X BUCK /WOOD FRAMING
BY OTHEn, 2X BUCK
TO BE PROPERLY SECURED
#10 WOOD SCREW
#10 WOOD SCREW
RIGID FILLER
}
1 3/8" MIN.
EMBEDMENT
3-- THREAD PITCHES
BEHOND SUBSTRATE
MIN. PENETRATION
APPROVED SEALANT
BY OTHERS
3- THREAD PITCHES
BEHOND SUBSTRATE
MIN. PENETRATION
REVD
DESCRIPNON
DAVE I APPROVED
APPROVED SEALANT
BY OTHERS
16GA. MIN.
STEEL STUD
EXTERIOR $X INTERIOR
HEAD INSTALLATION DETAIL
!MBA. METAL FRAMING
HEAD SHOWN JAMB IS SIMLAR
RIGID FILLER
1/4" MAX.
SHIM
#10 TEK SCREW
EXTERIOR rrll 4. I1 I INTERIOR
SILL INSTALLATION DETAIL
160A. METAL FRAMING
PGT INDUSTRIES
1070 TECHNOLOGY DRIVE
NOKOMIS, FL 34275
3LT HR2810MI PVC HORIZONTAL ROLLER WINDOW
130" x 63"
BOX FRAME INSTALLATION DETAILS
cowl:
TJH
OWLS NO.
08 -00844
C RS,
SMX NTS !DATE 09/02/09 I SHEET 2 OF 4
#10 TEK SCREW
RIGID FILLER
1/4" MAX.
SHIM
16GA MIN.
STEEL STUD
1 1/4" MIN.
EMBEDMENT
APPROVED SEALANT
BY OTHERS
APPROVED SEALANT
BY OTHERS
1/4 MAX.
I SHIM
1 1/4" MIN.
EMBEDMENT
EXTERIOR
EXTERIOR INTERIOR
HEAD INSTALLATION DETAIL
IX BUCKMASONRVAX)NCRETE
HEAD SHOWN JAMB IS SIMILAR
2 5/8" MIN.
EDGE DIST.
SILL INSTALLATION DETAIL
1X BUCKMASONRY /CONCRETE
f MASONRY /CONCRETE
BY OTHERS
IX BUCK BY OTHERS,
1X BUCK TO BE
PROPERLY SECURED 1/4" MAX.
RIGID FILLER SHIM
INTERIOR
3/16" ITW
TAPCON
RIGID FILLER
1X BUCK BY OTHERS,
1X BUCK TO BE
PROPERLY SECURED
4
1/4" MAX.
SHIM
APPROVED SEALANT
BY OTHERS
2X BUCK/WOOD FRAMING
BY OTHERS, 2X BUCK
TO BE PROPERLY SECURED
APPROVED SEALANT
BY OTHERS
EMBEDMENT P-Wil
man ri .... —_
i r 3111 11110
�
EXTERIOR N N II INTERIOR
HEAD INSTALLATION DETAIL
7X BUCIVWOOD FRAMING
HEAD SHOWN JAMB IS SIMILAR
EXTERIOR I M I INTERIOR
111
.011 I H
„11J
SILL INSTALLATION DETAIL
2X BUCKNVOOD FRAMING
2X BUCK/WOOD FRAMING
BY OTHERS, 2X BUCK
TO BE PROPERLY SECURED
RIGID FILLER
#10 WOOD SCREW
#10 WOOD SCREW
RIGID FILLER APPROVED SEALANT
BY OTHERS
1 3/8" MIN.
EMBEDMENT
3- THREAD PITCHES
BEHOND SUBSTRATE
MIN. PENETRATIO
3- THREAD PITCHES
BEHOND SUBSTRATE
MIN. PENETRATION
RVVIONS
REVI
DESCrmmaN
OM J APPROVED
APPROVED SEALANT
BY OTHERS
EXTERIOR 1 d) J INTERIOR
HEAD INSTALLATION DETAIL
BOA. METAL FRAMING
HEAD SHOWN JAMB IS SIMILAR
EXTERIOR y INTERIOR
SILL INSTALLATION DETAIL
108.4. METAL FRAMING
PGT INDUSTRIES
1070 TECHNOLOGY DRIVE
NOKOMIS, FL 34275
3LT HR2B10MI PVC HORIZONTAL ROLLER WINDOW
130" x 63"
FLANGE FRAME INSTALLATION DETAILS
DRAWN:
TJH
r . NO.
0B -00544
8CAE NTS PATE 09/02/09 iT3 OF 4
160A. MIN.
SII_LL STUD
RIGID FILLER
1/4" MAX. J
SHIM
#10 TEK SCREW
RIGID FILLER
1/4" MAX.
SHIM
16GA. MIN.
STEEL STUD
a
29/64"
HEAD & JAMB (8301)
VINYL PVC .075"7HICK
INNER INTERLOCK RAIL (8308) OUTER INTERLOCK RAIL (8307)
VINYL PVC .07" THICK VINYL PVC .07"THICK
1 11/16°
1
5P ' 9/64"
25/64" T sill TRACK
ALUMINUM EMOTE 46" THICK
7/8"
1/8" HS
.090 SGP
BY DUPONT
1/8° HS
EXTERIOR
SIKAFLEX
552
GLASS TYPEA
1/8" TEMP
SILL (8303)
VINYL PVC .075" THICK
1/8" HS
INTERIOR EXTERIOR
2 13/64 - 7 2 3/16"
1 15/32"
HORIZONTAL SASH (8305)
VOJ19. PVC Or THICK
1 19/64" —
HS INSERT
(NC -RW-PR -118)
6083-75 AL UMINUM .063" THICK
1 1/2"
5/16"
090" SGP
BY DUPONT
1/8 HS
MITER(OR
GLASS TYPE B
51/64"
5/32" J
RIGID FILLER
VINYL PVC .15' THICK
T
1 17/64° - r -
2 25/64"
}
15/32
1
VERTICAL SASH (8306)
VINYL PVC .07 THICK
25/32 I
2 35/64"
r J i�
d 1 59/64
VERTICAL STIFFENER
(NC -RW-PR -113)
ALUMINUM &063- T5.08" THICK
REVCRO
REV I IIESCRIPRDN
I DATE I APPROVED
53/64
63/64"
5/16" PLAIN BEAD (8321)
VINYL PVC.06"THICK
---}- 1 3/64"
51/64"
STIFFENER (ST1007B)
16GA GALVANIZED STEEL
1
83/84°
5/16" LIFT BEAD (8320)
VINYL PV C.06"TTTICK
1 3/64°
iLLiJ 1 32"
7/8 LIFT BEAD (8324)
SASH INSERT (NC -RW-PR -117) VINYL PVC.08'THICK
$083.78ALL .085 THICK
5/32° R G ID FILLER
VINYL PVC .15"THICK
I .-. 17/64"
83/64"
1 39/64"
7/8° P LAIN BEAD (8325)
VINYL PVC .05" IHJGK
PGT INDUSTRIES
1070 TECHNOLOGY DRIVE
NOKOMIS, FL 34275
3LT HR2810MI PVC HORIZONTAL ROLLER WINDOW
130" x 63"
COMPONENTS AND GLAZING DETAILS
auwm
TJH
I DWG NO
08 -00844
NTS DATE 09/02/09 ! SHEET 4 OF 4
I 1 9/32"
%sit, LOP
¢r: a
TAT OF
•�•°F•ft0R10
A 1 N j V. s.
Florida Building Code Online
Bc15 Home I Log in ! User Rebvatbn Hot Topics I Submr Surcharge I Stn &Faits Publications 1 FBC Stuff KM Site Map 1 Lbds j Seiuch ;
Product Approval
USER: public User
Product n al Merw > Ptg¢uet orPnoitation Search > ton LLst > Appasrti m new
FL#
Application Type
Code Version
Application Status
Comments
Archived
Product Manufacturer
Address /Phone/EmaII
Authorized Signature
Technical Representative
Address/Phone /Email
. Quality Assurance Representative
Address/Phone/Email .
Category
Subcategory
Compliance Method
Florida Engineer or Architect Name who developed
the Evaluation Report
Florida license
Quality Assurance Entity
Quality Assurance Contract Expiration Date
Validated By
Certificate of Independence
Referenced Standard and Year (of Standard)
http:// www .fioridabuilding.org/pr /pr_app dtl.aspx?param=wGEVX:..
PGT Indu§ tries
1070 Technology Drive
Nokomis, FL 34275 •
(941) 486 -0100 Ext 22318
druark@pgtindustries.com
Robert Clark
bclark @pgtlndustries.corn
Robert clerk
1070 Technology Dr.
Venice, FL 34275
(941) 480-1600 Ext21106
bciark @pgtindustriescom
Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
• Evaluation Report - Hardcopy Received
Luis Roberto Lomas
PE -62514
Keystone Certifications, Inc.
12/31/2011
Steven M. Urlch, PE
• Validation Cheddist - Hardcopy Received
FL13045 RO COI 511390.pdf
Startdatrd
AAMA/WDMA/CSA 101/LS.2/A440
ASTM E 1886
ASTM E 1886
ASTM E 1996
ASTM E 1996
TAS 201
TAS 202
TAS 203
2005
2002
2005
2002
2005
1994
1994
1994
1 of 3 2/28/2011 2:48 PM
Florida Building Code Online
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
bate Approved
Summary of Products
http://www.floridabuilding.org/pr/pr app dtl.aspx?paranz= wGEVX...
Method 1 Option D
09/09/2009
09/10/2009
09/15/2009
10/13/2009
FL #
13045.1
13045.2
13045.3
Model, Number or Name
Description
PW2720 PVC Fixed Window
PW2720 PVC Fixed Window 48 1/4" x 96"
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: +65/ -80
Otter: Rigid PVC From LB. Plastics AAMA Certified
(LBP-1)
Installation Instructions
FL13045 RO II 08- 00847.pdf
Verified By: Luis Roberto Lomas, P.E. 62514
Created by Independent Third Party: Yes
Evaluation Reports
FL13045 RO AE 511390.odf
FL13045 RO AE NOA 05- 1208.02 Dupont PVB.pdf
FL13045 RO AE NOA 07- 1116.04 Dupont SGP.pdf
Created by Independent Third Party: Yes
PW2720 PVC Fixed Window
PW2720 PVC Fixed Window 53 1/4" x 84 1/4"
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant Yes
Design Pressure: +65/ -80
Other: Rigid PVC From LB. Plastics AAMA Certified
(LBP -1)
Installation Instructions
FL13045 RO II 08- 00848.odf
Verified By: Luis Roberto Lomas, P.E. 62514
Created by Independent Third Party: Yes
Evaluation Reports
FL13045 RO AE 5113914:df
FL13045 . RO AE NOA 05- 12.08.02 Dupont PVB.sxff
FL13045. RO AE NOA 07- 1116.04 Dupont SGP.pdf
Created by Independent Third Party: Yes
PW2820 PVC Fixed Window
PW2820 PVC Fixed Window 48 1/4 x 96"
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant Yes
Design Pressure: +100/-120
Other: Rigid PVC From LB. Plastics AAMA Certified
(LBP -1)
Installation Instructions •
FL13045 RO II_08- 00849.odf
Verified By: Luis Roberto Lomas, P.E. 62514
Created by Independent Third Party: Yes
Evaluation Reports
FL13045 RO AE 511392.pdf
FL13045 RO AE NOA 07- 1116.04 Dupont SGP.pdf
Created by Independent Third Party: Yes
13045.4 I PW2820 PVC Fixed Window
PW2820 PVC Fixed Window 53 1/4" x 84 1/4"
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant Yes
Design Pressure: +100/ -120
Other: Rigid PVC From LB. Plastics AAMA Certified
(LBP-1)
Installation Instructions
FL13045 RO II 08-00850.pdf
Verified By: Luis Roberto Lomas, P.E. 62514
Created by Independent Third Party: Yes
Evaluation Reports
FL13045 R0 AE 511393.odf
FL13045 RO AE NOA 07- 1116.04 Dupont SGP.pdf
Created by Independent Third Party: Yes
Plot -2820 PVC. Fixed Window
PW2820. PVC Fixed Window 53" x 78'
Lim '•- of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant Yes
Design Pressure: +120/ -120
Other: Rigid PVC From LB. Plastics AAMA Certified
Installation Instructions
FL13045 RO 11 08- 00851,odf
Verified By: Luis Roberto Lomas, P.E. 62514
Created by Independent Third Party: Yes
Evaluation Reports
FL13045 RO AE 511394.odf
2 of 3 2/28/2011 2:48 PM
Florida Building Code Online
lmp: / /www.floridabuilding.org/pr /pr app dtl.aspx?paranrwGEVX...
(LOP -1)
FL13045 RO AE NOA 07-11 6.04 Dupont SOP.pdf
Created by Independent Third Party: Yes
Next
Departmeet of commmr@y Affahs
Fkrdda lialkling code One
codes ands nderds •
2555 Shumard Oak Boulevard
Tallahassee, Florida 32399 -2100
(850) 487 -1824, Fax (830) 414 -8436
IN 2000 - 2010 The State of Florida. All rIghls reserved.
R ac v Stat 1 CANNN9Leaftmeal I dSteedlEtataign= I Plag-In software 1 CatiPIECer_SletiOASPIMY 1 Conteetile
Product Approval Accepts:
3 of 3 2/28/20112:48 PM
L. Roberto Lomas P.E. Engineering Evaluation Report
1432 Woodford Rd
Lewisville, NC 27012 Report No.: 519 394
336-9459695
Manufacturer. POT Industries
1070 Technology Drive
Nokomis, FL 34275
Product Line: PW2820 PVC Fixed Window - Impact
Compliance:
The above mentioned product has been evaluated for compliance with the requirements of the Florida Department of
Community Affairs for Statewide Acceptance per Rule 9B-72.070 method 1(d). The product listed herein complies with
Requirements of the Florida Building Code.
Supporting Technical Documentation:
1. Approval document drawing number 08- 00851, titled PW2820 PVC Fixed Window- Impact, prepared, signed and
sealed by Luis Roberto Lomas P.E.
2. Test Report No. NCTL 210 - 3635 -1, signed and sealed by Gerard J. Ferrara P.E.
National Certified Testing Laboratories, Orlando, FL.
TAS 201-94 Large Missile Impact Test
TAS 202 -94 Uniform Static Air Pressure, t120.0psf design pressure, 25psf water infiltration
TAS 203-94 Cyclic Pressure Loading, ±150.0psf design pressure
3. Test Report No. NCTL 210-3635 -IA, (box, flange and fin installation), signed and sealed by Gerard J. Ferrara P.E.
National Certified Testing Laboratories, Orlando, FL
AAMA/WDMA/CSA 101II.S2/A440 -05
Design pressure: ±120.0psf
Water penetration resistance: 25psf
ASTM E 1886 -02/ -05 and ASTM E1996-02/ -05
ASTM E 18861E 1996 Large Missile Impact Test, Level D, Wind Zone 4
ASTM E 1886/E 1996 Cyclic Load Test, ±150.0psf design pressure
4. Anchor calculations, report number 511394 -1, prepared, signed and sealed by Luis Roberto Lomas P.E.
5. Comparative analysis report number 511394 -2, prepared, signed arid sealed by Luis Roberto Lomas P.E.
Limitations and Conditions of use:
• Maximum design pressure: ±120.0psf
• Maximum overall size: 53" x 78"
• Units to be glazed per ASTM E1300 with:
o 1 1/16° IGU consisting of outboard laminated lite consisting ot: 3/16" HS — 0.090° Sentry GlasPlus by
Dupont — 3/16° HS — Air — Inboard lite 3/16° Temp.
• This product is rated to be used in the HVHZ.
• This product is impact resistant and does not require impact protection in wind borne debris regions.
• Frame material to be extruded white rigid PVC .075" thick.
Installation: Units must be installed in accordance with approval document 08-00851
Certification of Independence:
Please note that I don't have nor will acquire a financial interest in any company manufacturing or distributing the
product(s) for which this report Is being issued. Also, I don't have nor will acquire a financial interest in any other entity
involved in the approval process of the listed product(s).
1 of 1
\` 11111 f
\\ " 0 4 /4 %
N. •.,C E N ' 01 ,. :; .
4 4564:4
f'
% V r • tri ■7": tit
Luis R. Lomas, P.E.
. FL No.: 62514
09/09/2009
DESIGN PRESSURERAT1NG
IMPACT RATING
t12QPSF
LARGE AND SMALL
MISSILE IMPACT
4" MAX. --{
4" MAX.
8" MAX. t
O.C. TYP.
emwil
4" MAX.
53 MAX. WIDTH
a" MAX. 0.0. TYP.
I I 1 1 1
+-- 49 5/8 MAX. D.L.O.
PW28,20 PVC FIXED WINDOW
EXTERIOR VIEW
74 /4°
MAX.
D.L.O.
4" MAX.
75"
MAX.
HEIGHT
SHEET NO.
1
2
3
AteRitlTum design pressure capacity chart (psfJ
TABLE OF CONTENTS
DESCRIPTION
ELEVATION, ANCHORING AND NOTES
CROSS SECTION, GLAZING DETAILS AND COMPONENTS
INSTALLATION DETAILS
REVISIONS
REV
OESCRIPRON I DATE I APPROVED
NOTES:
1) THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO
COMPLY WITH REQUIREMENTS OF THE FLORIDA BUILDING CODE.
2) WOOD FRAMING AND MASONRY OPENING TO BE DESIGNED AND
ANCHORED TO PROPERLY TRANSFER ALL LOADS TO STRUCTURE.
FRAMING ANO MASONRY OPENING 15 THE RESPONSIBILITY OF THE
ARCHITECT OR ENGINEER OF RECORD.
3) UNITS MUST BE GLAZED PER ASTM E1300 WITH 1 1/16" IGU
LAMINATED GLASS CONSISTING OF LAMINATED EXTERIOR LITE: 3/16"
HS - .090" SGP BY DUPONT - 3/16" HS -- AIR - 3/16" TEMP
INTERIOR LITE
4) APPROVED IMPACT PROTECTIVE SYSTEM IS NOT REQUIRED FOR THIS
PRODUCT IN WIND -BORNE DEBRIS REGIONS.
5) SHIM AS REQUIRED AT EACH INSTALLATION ANCHOR WITH LOAD
BEARING SHIM. SHIM WHERE SPACE OF 1/16" OR GREATER OCCURS.
MAXIMUM ALLOWABLE. SHIM STACK TO BE 1/4 ".
6) FOR INSTALLATION INTO WOOD FRAMING OR 2X BUCK USE #10
WOOD SCREW WITH SUFFICIENT LENGTH TO ACHIEVE A 1 3 /6"
MINIMUM EMBEDMENT INTO SUBSTRATE. LOCATE ANCHORS AS SHOWN
IN ELEVATIONS AND INSTALLATION 'DETAILS.
7) FOR INSTALLATION INTO CONCRETE /MASON SE 3/16" ELC�>
ULTRACON TAPCON WITH SUFFICIENT LENGTH • 1/4
MINIMUM EMBEDMENT INTO SUBSTRATE. LOCATE ANCHORS AS SHOWN
IN ELEVATIONS AND INSTALLATION DETAILS.
8) FOR ANCHORING INTO METAL FRAMING USE #10 TEK SELF TAPPING
SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A MINIMUM
EMBEDMENT OF THREE THREADS PAST THE FRAME THICKNESS.
LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION
DETAILS.
9) ALL FASTENERS TO BE CORROSION RESISTANT.
10) INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH
ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS, AND
ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS
LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW:
A. WOOD -- MINIMUM SPECIFIC GRAVITY OF C=0.42
B. CONCRETE - MINIMUM COMPRESSIVE STRENGTH OF 3.200 PSI.
C. MASONRY - STRENGTH CONFORMANCE TO ASTM 0 -90, GRADE N,
TYPE 1 (OR GREATER).
D. METAL FRAMING - 1 6G (.060) MINIMUM THICKNESS
11) ALLOWABLE STRESS INCREASE OF 1/3 WAS NOT USED IN THE
DESIGN OF THE PRODUCT SHOWN HEREIN. WIND LOAD DURATION
FACTOR Cd =1.6 WAS USED FOR WOOD ANCHOR CALCULATIONS.
12) FRAME MATERIAL: EXTRUDED WHITE RIGID PVC .075" THICK.
PGT INDUSTRIES
1070 TECHNOLOGY DRIVE
NOKOMIS, FL 34275
PW2820 PVO FIXED WINDOW - IMPACT
53" x 78"
ELEVATION, ANCHORING AND NOTES
I
DRAWN: DWG N0.
TJH 08 -00835
scALE NTS I DATE 09/09/09 I $"EET 1 OF 3
otti two
71: ce P •' .�'
"HI it0
P neI.'W
dth'(In)
MEMELEMa]Eii
N:
Wail
50:0I
0
O
CM
150.0I
LLIM
LEEL]EF.:lMIt
]
LEMILIII=11.20
150.0
MI
1500E
100.0
'.
El=
, ,
150.0150.0EMEC
E E7
130.0
EEi&]El::&J
I]I,04
160
150.0
150:0
1500
1600
ital
EL• DII
g1EIIb1E
J
60.0
150.0
E 2t.1
150.0II,
�Ir
150.0
150 ..0
1500
150 .0
x'160.0
50.0'
150.0
Ejui:Exma
E[]
160.0
150.0
180. 0EZ;>m]Eja]
EI 21L
,E
150.0
150.0
EEO
150.0
ULU
150.0
ILF
EID
160.0
FIEMMEEI
flit
ta).1Il
iNI).wr"
IJ
7
., ,
]'
EMI
EIE
ILLEIEMEEEIE110
150.0
EMI
-1.�,.❑
150.0EMIE
IlIZE
Ik1dILMILLIlC1
LIME=
., ,
I�'�..�'
QM
160.0
1 5'.0
oqqp
El;'x
:Gal
liatJ
I
F.•
oa I Oak
150
MIME
MEME
EDO
EMI
I)F' Ira
MUM
MIItMIIM
mum
LEM
120.0
gm
LE
4" MAX. --{
4" MAX.
8" MAX. t
O.C. TYP.
emwil
4" MAX.
53 MAX. WIDTH
a" MAX. 0.0. TYP.
I I 1 1 1
+-- 49 5/8 MAX. D.L.O.
PW28,20 PVC FIXED WINDOW
EXTERIOR VIEW
74 /4°
MAX.
D.L.O.
4" MAX.
75"
MAX.
HEIGHT
SHEET NO.
1
2
3
AteRitlTum design pressure capacity chart (psfJ
TABLE OF CONTENTS
DESCRIPTION
ELEVATION, ANCHORING AND NOTES
CROSS SECTION, GLAZING DETAILS AND COMPONENTS
INSTALLATION DETAILS
REVISIONS
REV
OESCRIPRON I DATE I APPROVED
NOTES:
1) THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO
COMPLY WITH REQUIREMENTS OF THE FLORIDA BUILDING CODE.
2) WOOD FRAMING AND MASONRY OPENING TO BE DESIGNED AND
ANCHORED TO PROPERLY TRANSFER ALL LOADS TO STRUCTURE.
FRAMING ANO MASONRY OPENING 15 THE RESPONSIBILITY OF THE
ARCHITECT OR ENGINEER OF RECORD.
3) UNITS MUST BE GLAZED PER ASTM E1300 WITH 1 1/16" IGU
LAMINATED GLASS CONSISTING OF LAMINATED EXTERIOR LITE: 3/16"
HS - .090" SGP BY DUPONT - 3/16" HS -- AIR - 3/16" TEMP
INTERIOR LITE
4) APPROVED IMPACT PROTECTIVE SYSTEM IS NOT REQUIRED FOR THIS
PRODUCT IN WIND -BORNE DEBRIS REGIONS.
5) SHIM AS REQUIRED AT EACH INSTALLATION ANCHOR WITH LOAD
BEARING SHIM. SHIM WHERE SPACE OF 1/16" OR GREATER OCCURS.
MAXIMUM ALLOWABLE. SHIM STACK TO BE 1/4 ".
6) FOR INSTALLATION INTO WOOD FRAMING OR 2X BUCK USE #10
WOOD SCREW WITH SUFFICIENT LENGTH TO ACHIEVE A 1 3 /6"
MINIMUM EMBEDMENT INTO SUBSTRATE. LOCATE ANCHORS AS SHOWN
IN ELEVATIONS AND INSTALLATION 'DETAILS.
7) FOR INSTALLATION INTO CONCRETE /MASON SE 3/16" ELC�>
ULTRACON TAPCON WITH SUFFICIENT LENGTH • 1/4
MINIMUM EMBEDMENT INTO SUBSTRATE. LOCATE ANCHORS AS SHOWN
IN ELEVATIONS AND INSTALLATION DETAILS.
8) FOR ANCHORING INTO METAL FRAMING USE #10 TEK SELF TAPPING
SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A MINIMUM
EMBEDMENT OF THREE THREADS PAST THE FRAME THICKNESS.
LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION
DETAILS.
9) ALL FASTENERS TO BE CORROSION RESISTANT.
10) INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH
ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS, AND
ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS
LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW:
A. WOOD -- MINIMUM SPECIFIC GRAVITY OF C=0.42
B. CONCRETE - MINIMUM COMPRESSIVE STRENGTH OF 3.200 PSI.
C. MASONRY - STRENGTH CONFORMANCE TO ASTM 0 -90, GRADE N,
TYPE 1 (OR GREATER).
D. METAL FRAMING - 1 6G (.060) MINIMUM THICKNESS
11) ALLOWABLE STRESS INCREASE OF 1/3 WAS NOT USED IN THE
DESIGN OF THE PRODUCT SHOWN HEREIN. WIND LOAD DURATION
FACTOR Cd =1.6 WAS USED FOR WOOD ANCHOR CALCULATIONS.
12) FRAME MATERIAL: EXTRUDED WHITE RIGID PVC .075" THICK.
PGT INDUSTRIES
1070 TECHNOLOGY DRIVE
NOKOMIS, FL 34275
PW2820 PVO FIXED WINDOW - IMPACT
53" x 78"
ELEVATION, ANCHORING AND NOTES
I
DRAWN: DWG N0.
TJH 08 -00835
scALE NTS I DATE 09/09/09 I $"EET 1 OF 3
otti two
71: ce P •' .�'
"HI it0
GLASS GLASS BEAD
FRAME CROSS SECTION
3/16" HS
.090" SENTRY
GLASPLUS
BY DUPONT
3/16° HS
EXTERIOR
7/8" GLASS
BITE
SIKAFLEX
552
1 1/18°
GLAZING DETAIL
3/16" TEMP
INTERIOR
RIGID FILLER
FRAME
COVER
5/8'
2 19/84"
1
3 1/4"
FRAME (8304) •
RIGID PVC .075' TRICK
—1 1 49/64"
} 1 9/32" 1
1 / 4 "
33/6
COVER (8345)
MID PVC .08° THICK
T
}
27/
1/2"
RIGID FILLER
RIGID PVC .16" THICK
REVISIONS
DESCRPTION
DATE I APPROVED
17/64"
63/64"
7/8" PLAIN BEAD (8325)
ROID PVC .08° TRICK
PGT INDUSTRIES
1070 TECHNOLOGY DRIVE
NOKOMIS, FL 34275
PW2820 PVC FIXED WINDOW — IMPACT
53" x 78"
CROSS SECTION, GLAZING DETAILS AND COMPONENTS
DRAWN:
TJH
raft NO
08 -00835
-
SCALE NTS I DATE 09/09/09 IsKEEr2 OF 3
1 1/4" MIN.
EMBEDMENT
APPROVED SEALANT
BY OTHERS
1X PT BUCK
BY OTHERS, 1X BUCK
TO BE PROPERLY
SECURED
1 1/4" MIN.
EMBEDMENT
APPROVED SEALANT
BY OTHERS
1X PT BUCK
BY OTHERS, 1X BUCK
TO BE PROPERLY
SECURED
2 1/2 MIN.
EDGE DISTANCE
4 4
A'
4 4
EXTERIOR , INTERIOR
HEAD DETAIL
CONCRETE/MASONRY FLANGE INSTALLATION
HEAD SHOW JAMBS AND SILL SIMILAR
2 1/2 MIN.
EDGE. DISTANCE
• a
O0
EXTERIOR 1 INTERIOR
•
•
.4 d:
HEAD DETAIL
CONCRETEJMASONRYBOXFRAME WSTALLATION
HEAD SHOWN, JAMBS AND SILL SIMILAR
1/4" MAX. ,I
SHIM SPACE
RIGID FILLER
MASONRY /CONCRETE
BY OTHERS
1/4 MAX. J.
SHIM SPACE
RIGID FILLER
3/18" ELCO
ULTRACON
TAPCON
{
3/18 ELCO
ULTRACON
TAPCON
MASONRY /CONCRETE
BY OTHERS
APPROVED
SEALANT
BY OTHERS
APPROVED
SEALANT
BY OTHERS
2X BUCK/WOOD FRAMING
BT OTHERS, 2X BUCK TO
BE PROPERLY SECURED
�
1/4' MAX.
SHIM SPACE
RIGID FILLER
#10 WOOD
SCREW
EXTERIOR INTERIOR
HEAD DETAIL
WOOD FRAMING OR 2X BUCK RANGE INSTALLATION
HEAD SHOWN, JAMBS AND SILL SIMILAR
Mr Mi
L� ■
2X BUCK/WOOD FRAMING
7 BT OTHERS, 2X BUCK TO
BE PROPERLY SECURED
1 3 /8 MIN. METAL STUD
EMBEDMENT 160A MIN
BY OTHERS
L
1 3/8 MIN.
EMBEDMENT
1/4 MAX. •• I
SHIM SPACE
RIGID FILLER
#10 CREW OD
EXTERIOR ' ' + ' INTERIOR
HEAD DETAIL
WOOD FRAMING'OR 2X SUCK SOX FRAME INSTALLATION
HEAD SHOWN, JAMBS AND SILL SIMILAR
APPROVED
SEALANT
BY OTHERS
METAL STUD
16GA MIN
BY OTHERS'
APPROVED
SEALANT
BY OTHERS
REVISIONS
RV I
DESCRIPTION I DATE I APPROVED
HEAD DETAIL
METAL FRAMING FLANGE INSTALLATION
HEAD SHOWN, JAMBS AND SILL SIMILAR
#10 TEK
INTERIOR SCREW
EXTERIOR T INTERIOR
HEAD DETA L
METAL FRAMING BOX FRAME INSTALLATION
HEAD SHOWN, JAMBS AND SILL SIMILAR
1 /4" MAX.
SHIM SPACE
PGT INDUSTRIES
1070 TECHNOLOGY DRIVE
NOKOMIS, FL 34275
PW2820 PVC FIXED WINDOW — IMPACT
53" x 78"
INSTALLATION DETAILS
DRAWN:
TJH
DW3 N0.
1 08 -00835
scALE NTS !WE 09/09/09 IsHEET3 OF 3
3— THREAD PITCH MIN.
BEYOND SUBSTRATE
_ 3- THREAD PITCH MIN.
BEYOND SUB
1/4" MAX.
SHIM SPACE
RIGID FILLER
#10 T£K
SCREW
�� I 1
04/
.‘• 4 • • EN
44.
- .:i ° STATE OP
I ill/ III ILO
NOTICE OF COMMENCEMENT
A RECORDED COPY MUST BE POSTED ON THE JOB SITE AT TIME OF FIRST INSPECTION
PERMIT NO.
STATE OF FLORIDA:
COUNTY OF MIAMI -DADE:
THE UNDERSIGNED hereby gives notice that improvements will be ��•� 1
property, and in accordance with Chapter 713, Florida Statutes, the follbfi►ig jrjon
is provided in this Notice of Commencement. off'
9. Expiration date of this Notice of Commencement
123.01 -52 PAGE3 11/07
1 1-3 0 20(0- 034
TAX FOLIO NO. 0060
Signatu f Owne ner(s 's Aut ed Officer /Director/Partner/Manager who signed above:
By � By
11111111 1111111111111111111 111111111111111111
CFN 2011R.e 21, . 2
OR Ek 27639 E's 2515; tips)
RLCURI LG 04./04/2011 11:01 :5'
HARVEY RUVIWr CLERK OF COURT
MIAMI-DAC'E COUP #T`t r FLORIDA
LAST PAGE
Z a o ce above reserved for use of recording office
1. Legal description of property and street/address: jd m Sf2/Lc5 . 0" /la
I6 l
'etc!' n1E loo sr ih /P rni $7104e5 3/3g
2. Description of improvement: uJI#Jt OM )S •
3.Owner(s) name and address: /Et- RO BB /Al . 810 NE /OO Sr //9 /Ain/, P( .• 3/3 f
Interest in property: OWA) E12.
Name and address of fee simple titleholder:
4. Contractor's name, address and phone number: Florida Home - improvement Associates
4070 SW 30th Ave. Hollywood, Florida 33312 Phone 954 - 792 -4415
5. Surety: (Payment bond required by owner from contractor, if any)
Amount Name, address and phone number:
A of f r.
bond $
6. Lender's name and address:
7. Persons within the State of Florida designated by Owner upon whom notices or other doc • =nts may be served as provided by
Section 713.13(1)(a)7., Florida Statutes,
Name, address and phone number.
8. In addition to himself, Owners designates the following person(s) to = • :Ave a copy of the Lienor's Notice as provided in Section
713.13(1)(b), Florida Statutes.
Name, address and phone number
(the expiration date is 1 year from the date of recording unless a different date Is specified)
WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED
IMPROPER PAYMENTS UNDER CHAPTER 713, PART I, SECTION 713.13. FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR
IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE
FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK
OR RECORDING YOUR NOTICE OF COMMENCEMENT.
Signatu Officer/Director/Partner/Manager
By By r!?!3 1191,1 Print Name /)H T// eZ /7.06.6/A-1 By Name
Title/Office Title/Office
STATE OF FLORIDA
COUNTY OF MIAMI -DADE /)/)
The fore oing instrument was acknowledged before me this .29 ` day of /' / A1Z
By / /J /1✓ - g-p/,/b/N
❑ Individually, or ❑ as for
a known, or ❑ produced the following type of identifi 'on:
Signature of Notary Public:
Print Name: 5 - U Stn /E
(SEAL)
VERIFICATION PURSUANT TO SECTION 92.525, FLORIDA STATUTES
Under penalties of perjury, I declare that I have read the foregoing and
that the facts stated in it are true, to the best of my knowledge and belief.
Florida Hare- Improvement Assoc.
4070 SW 30th Ave:
mod, n.83312
QQ-e//
• " ° �i STEVE P. SMIZIK
? *; :,r_ MY COMMISSION I# DD 947362
.....+•� Bonded Thru Notmy 37, 2013 a wdteis