Loading...
358 NE 101 St (5)MIAMI SHORES VILLAGE BUILDING INSPECTION DEPARTMENT APPLICATION FOR BUILDING PERMIT Application is hereby made for the approval of the detailed statement of the plans and specifications herewith submitted for the build- ing or other structure herein described. This application is made in compliance and conformity with the Building Ordinance of Miami Shores Village, Florida, and all provisions of the Laws of the State of Florida, all ordinances of Miami Shores Village and all rules and regulations of the Building Division of Miami Shores Village shall be complied with, whether herein specified or not. A copy of approved plans and specifications must be kept at building during progress of the work. Date 7/20/62 ,19 Owner's Name and Address.. Minnilee Hearn N Street_... BM ....E. Z. 101st St. Registered Architect and /or Engineer Name and address of licensed contractor ?rotectu Awning t -es Inc. 701 W. 25th L,t. Hialeah Location and legal description of lot to be built on: _ Lot__ of 4 and 5 Block39 Enixammumaarataxamn Miami Shores 1 ammended Street and Number where work is to be done 3 ,58 __N..._ State work to be done and purpose of building (by floors) _Inst:c 11 alum. fold-down awnings and for no other purpose. New Building Remodeling Addition Repairs No. of Stories To be constructed of Kind of foundation Roof Covering Estimated Total cost of improvements $ 714 00.00 Amount of Permit $ 260 Zone cubage required _Plan Cubage Distance to next nearest building Size of Building Lot Maximum live load to be borne by each floor I hereby submit all the plans and specifications for said building. All notices with reference to the building and its construction may be sent to P,rQtactu_.AmiPg Sales,_ Inc, P. 0. Box 595 Hialeah The undersigned applicant for this building permit does hereby certify that he understands and accepts his obligations as an employer of labor under the Florida Workmen's Compensation Act, being Section 5966, Compiled General Laws of Florida, Permanent Supplement, and has complied with the provisions thereof, and will require similar compliance from all contractors or sub - contractors employed by him in the work to be performed under this permit; and will post or cause to be posted for inspection on the site of the work such public notice or notices as are required by the Act. The undersigned agrees to employ only such subcontractors, on work to be per rmed under this permit, as are licensed by Miami Shores Village. �- otectu At ingT es, .uc. Remarks (Signed -.r1-l_l -c.e STATE OF FLORIDA, COUNTY OF DADE. ss. Before me, the undersigned authority, a notary public, duly authorized to administer oaths and take acknowledgments, personally ap- peared to me well known, and who, being by me first duly sworn, upon oath deposes and says that he is the of the above described construction, that he has carefully read the foregoing application, and that he did sign the same, and that all facts therein by him stated are true. Permit No �� Date__` Read, Sworn to and Subscribed before me. Disapproved ate (Signed) G ng Inspector My Commission Expires Notary Public, State of Florida PLANNING BOARD DATE Chairman Member Member Member Member Member Council Approved Date Disapproved Date NOTE: A charge of $1.00 will be made for making corrections or changes to this application after approval has been obtained from the Planning Board. A re- inspection fee of $1.00 will be charged when such re- inspection is made necessary by improper notice for inspection or faulty materials and /or workmanship. PERMIT APPLICATION FOR MIAMI SHORES VILLAGE Date 4-l?)-060 Job Address .55g 64 E 10 (ST • Tax Folio Legal Description I t E WES`r I �L OF LOT4 AU) 5 Historically Designated: Yes No ✓ Owner/Lessee / Tenant LA1UQCY11l? (,( v P (Zl U tQ_ Master Permit # 1/4 5 Owner's Address - 5 1 5 S N.E. (O ( S1 - T • Phone Contracting Co. B - e OLIO ST (ZVOTt f OC72P . Address 1 �j ( 5 ( 5 - ))cA 2 dT 306 Dot . 4404; Qualifier TOP/9E Ic L6-0 E z SS# Phone 3 54'1/ -9 ?&5 State # CSC - O 227 Z Municipal # Competency # Ins. Co. Architect/Engineer _ Address Bonding Company Address Mortgagor Address Permit Type (circle one): BUILDING ELECTRICAL PLUMBING MECHANICAL ROOFING PAVING FENCE SIGN WORK DESCRIPTION O P (c ; , j. caw ,davk (cr c. ( :1 U 0Jo a7 Opa . 4uge; S s .xi bo . Square Ft. Estimated Cost (value) go (> WARNING TO OWNER: YOU MUST RECORD A NOTICE OF COMMENCEMENT AND YOUR FAILURE TO DO SO MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY (IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.) ,, Application is hereby made to obtain a permit to do work and installation as indicated above, and on the attached addendum (if applicable). I certify that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that separate permits are required for ELECTRICAL PLUMBING, SIGNS, POOLS, ROOFING and MECHANICAL WORK. OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Furthermore, I authorize the above -named contractor to do the w• stated. 7/00 Presi t o Notary as to Owi My Commission FEES: PERMIT APPROVED: Zoning Mechanical 0 6610,(70116VA4E ROSSITERIX,e / F44' A444190 20 90 :,! IRE D ecember 10 10 2000 c kj 1, Baled Thm Notary Public Undotwdtas RADON Notary : j o Contractor f Owner- Builder My Co / ssion C.C.F. ` NOTARY —�© BOND' � ' T TOTAL DUE 3 0 Building 1/ Electrical Plumbing Structural Engineer MIAMI -DADE PRODUCT CONTROL NOTICE OF ACCEPTANCE T.M. Window & Door Co. 601 N.W. 12th Ave. Pompano Beach FL 33069 The expense of such testing will be incurred by the manufacturer. Acceptance No.:99- 1201.06 Expires:12 /31 /2000 Approved:02 /2 /2000 CONDITIONS BUILDING CODE & PRODUCT REVIEW COMMITTEE Internet mail address: postmas ter ®buildingcodeonline.com MIAMI -DADE COUNTY, FLORIDA METRO -DADE FLAGLER BUILDING BUILDING CODE COMPLIANCE OFFICE METRO -DADE FLAGLER BUILDING 140 WEST FLAGLER STREET. SUITE 1603 MIAMI, FLORIDA 33130-1563 (305) 375 -2901 FAX (305) 375 -2908 CONTRACTOR LICENSING SECTION (305) 375 -2527 FAX (305) 375 -2558 CONTRACTOR ENFORCEMENT SECTION (305) 375 -2966 FAX (305) 375 -2908 PRODUCT CONTROL DIVISION Your application for Product Approval of: (305) 375 -2902 FAX (305) 372 -6339 PA Series Aluminum Awning Window under Chapter 8 of the Code of Miami-Dade County governing the use of Alternate Materials and Types of Construction, and completely described herein, has been recommended for acceptance by the Miami-Dade County Building Code Compliance Office (I3CCO) under the conditions specified herein. This approval shall not be valid after the expiration date stated below. I3CCO reserves the right to secure this product or material at anytime from a jobsite or manufacturer's plant for quality control testing. IFthis product or material tails to perform in the approved manner, BCCO may revoke, modify, or suspend the use of Such product or material immediately. BCCO reserves the right to revoke this approval, if it is determined BCCO that this product or material fails to meet the requirements of the South Florida Building Code. Raul Rodriuuer Chief Product Control Division TIIIS IS THE COVERSUEET, SEE ADDITIONAL ('AGES FOR SPECIFIC AND GENERAL This application for Product Approval has been reviewed by the I3CCO and approved by the I3uildint Code and Product Review Committee to be used in Dade County, Florida under the conditions set forth above. t� •ranciscu .. Quintana, R.A. Director I of Miami -Dade County 13u1Idin�t Code Compliance Office Ilomcpugc: blip : / /www.buildingcodeonline.com T. M. Window & Door Co. APPROVED EXPIRES 2 of 3 ACCEP'T'ANCE No.: 99- 1201.06 NOTICE 01? ACCEPTANCE: STANDARD CONDITIONS FEB 2 5 2000 : December 31, 2000 1. SCOPE 1.1 This renews Notice of Acceptance No. 98- 1223.08, which was issued on January 28, 1999. It approves an aluminum awning window, as described in Section 2 of this Notice of Acceptance, designed to comply with the South Florida Building Code, 1994 Edition for Miami -Dade County, for the locations where the pressure requirements, as determined by SFBC Chapter 23, do not exceed the Design Pressure Rating values indicated in the approved drawings. 2. PRODUCT DESCRIPTION 2.1 The PA -3 Series Aluminum Awning Window and its components shall be constructed in strict compliance with the following documents: Drawing No. PA -3ASS, titled "PA -3 Assembly Drawing," prepared by T. M. Window & Door, dated February 3, 20008, Sheet 1 of 1, bearing the Miami -Dade County Product Control Approval stamp with the Notice of Acceptance number and approval date by the Miami -Dade County Product Control Division. These documents shall hereinafter be referred to as the approved drawings. 3. LIMITATIONS 3.1 This approval applies to single unit applications only, as shown in approved drawings. 4. INSTALLATION 4.1 The aluminum awning window and its components shall be installed in strict compliance with the approved drawings. 4.2 The installation of this product will require a hurricane protection system. 5. LABELING 5.1 Each window unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved ". 6. BUILDING PERMIT REQUIREMENTS 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance. 6.1.2 Duplicate copies of the approved drawings, as identified in Section 2 of this Notice of Acceptance, clearly marked to show the components selected for the proposed installation. 6.1.3 Any other documents required by the Building Official or the South Florida Building Code (SFBC) in order to properly evaluate the installation of this system. Manu I Perez, P.E., Product CpifFol Examiner Produc ntrol Division • T M COMPARATI NEANALYSIS WINDOW - AND DOOR COMPANY 3 -1 AWNING WINDOW DESIGN LOADCAPACITY- -LOADS IN PSI" BASED ON BIDE COUNIYVIA 98-1223.08 NARROW VENTS STANDARD VENTS CALL SSB ANNEAL 1/8' ANNEAL 3 /16" ANNEAL SSB ANNEAL 1/8" ANNEAL 3/16" ANNEAL SIZE WIDTH HEIGHT EXT INT. EXT INT. EXT INT. EXT INT. EXT INT. EXT INT. 12 191/8" X 26" 69 69 ' 69 69 69 69 69 69 69 69 69 69 13 19 1/8" X 38 318" 69 ' 69 69 69 69 69 69 69 69 69 69 69 14 19 1/8" X 50 5/8" 69 69 69 69 69 69 69 69 69 69 69 69 15 19 1/8" X 63" 69 69 69 69 69 69 69 69 69 69 69 69. 16 19 1/8" X 77 7 /8" 69 69 69 69 69 69 69 69 69 69 69 69 H32 26 1/2" X 26" 69 69 69 69 69 69 69 69 69 69 69 69 H33 26 1/2" X 38 3/8" 69 69 69 69 69 69 69 69 69 69 69 69 H34 26 1/2" X 50 5/8" 69 69 69 69 69 69 69 69 69 69 69 69 H35 26 1/2" X 63" 69 69 69 69 69 69 69 69 69 69 69 69 H36 26 1/2" X 77 7/8" 69 69 69 69 69 69 69 69 69 69 69 69 22 37" X 26" 69 69 69 69 69 69 69 69 69 69 69 69 23 37" X 38 3/8" 69 69 69 69 69 69 69 69 69 69 69 69 24 37" X 50 5/8" 69 69 69 69 69 69 69 69 69 69 69 69 25 37" X 63" 69 69 69 69 69 69 69 69 69 69 69 69 26 37" X 77 7/8" 69 69 69 69 69 69 69 69 69 69 69 69 32 53 1/8" X 26" 53 53 53 53 53 53 45 45 45 45 45 45 33 53 1/8" X 38 3/8" 53 53 53 53 53 53 45 45 45 45 45 45 34 53 1/8" X 50 5/8" 53 53 53 53 53 53 45 45 45 45 45 45 35 53 1/8" X 63" 53 53 53 53 53 53 . 45 45 45 45 45 45 36 53 1/8" X 77 7/8" 53 53 53 53 53 53 45 45 45 45 45 45 Note: Water 10.4 psi from ATLSF #1231.01 -97 07/16/1999 BILL OF MATERIAL PART NUMBER DESCRIPTICN MATERIAL / /� �. REMARKS 1 3 -55 ATW FRAME HEAD 1 ALUM 1 PER WINDOW 2 3 -42 ATW FRAME SILL 1 ALUM 1 PER WINDOW 3 3 —41 D ATW FRAME JAMB ALUM 2 PER WINDOW 4 3 -04 DRAW BAR 1 ALUM 1 PER WINDOW 5 3 -19 TORQUE 8AR ARM ALUM 1 PER WINDOW 6 3 -21 VENT ANO TRANSFER LINK ALUM 1 PER WINDOW 7 3 -23A VENT HEAD . ALUM 1 PER VENT 8 3 -24 VENT SILL ALUM 1 PER VENT 9 3 -50 BOTTOM VENT SILL ALUM 1 © BOTTOM VENTI 10 3 -25 VENT JAMS ALUM 2 PER VENT 11 3 -43 VENT HINGE ALUM 2 PER VENT 12 3 -53 VENT LOCK ALUM 2 PER VENT 13 3 -2003C FRAME WEATHERSTRIP VINYL AS AS REOUIRED REOUIRED 14 3 -2007A VENT HEAD WEATHERSTRIP VINYL 15 3 -3041 COYER PLATE ALUM 1 PER WINDOW 16 3 -5000 TORQUE BAR BEARING NYLON 1 PER WINDOW 17 3 -5003 TORQUE BAR ARM BUSHING NYLON 1 PER WINDOW 18 3 —A7000 SHOULDER ARM ALUM 1 PER WINDOW 19 3 -8012 VENT LOCK PIN DRAWBAR & HINGE RIVET STEEL ALUM 2 2 PER VENT PER VENT 20 3 -8014 21 - -- GLASS (558 OR DS8) A1.1U . GLASS AS REQUIRED 22 - -- GLAZING BEAD ALUM AS REOUIRED 23 3 -6006 I TORQUE BAR STEEL 1 PER WINDOW 24 3 -5013 BUSHING GUIDE NYLON 1 PER WINDOW 25 3 -6010 -AL CRAFT OPERATOR LINK ZINC 1 PER WINDOW 26 3 -8000 HOOK TO LINK RIVET ALUM. 2 PER VENT 27 3 -8005 HINGE KEY RIVET ALUM. 2 PER VENT 28 3 -3054 SCREEN FRAME ALUM. 1 PER WINDOW 29 3 -3055 STRETCHER CLIP ALUM. 4 PER WINDOW 3013 -3050 SCREEN FRAME CORNER ALUM. 1 4 PER WINDOW c U c r 1/4" SPACING I✓; -J,: t r 1/4" SPACING 11AX. 1 / SHIM AS REOUIREO r 1 /4" SPACING MAX. 2X BUCK VERTICAL INSTALLATION 3/16" DIA TAPCON 1 1/4 EMEEDMENT MIN. SHIM AS P.EOUIRED 1X BUCK VERTICAL! NSTALLATION 2" x F.T. W003 EL'C< 1 — X P.T. WOOD BUCK a Q O® RICO (1.1 Ill t #10 P.– 1 1/4" E',1EED u: . SHIM AS REOUIRED 1 /4 SPACING BUCK DIMENSION FRAME O.S.M. E3 1/4" !4 "TYP. MAX. -- { 1X BUCK HORIZONTAL INSTALLATION PA -3 AWNING ELEVATION! I A, 1 1 W1 11 ,. 1 al a ' D 1 v Revis:cns hlaterial DESIGN PRESSURE RATING (POSITIVE) =40.67 DESIGN PRESSURE RATING (NEGATIVE) —40.671 Orawn By: MH Date: 2/31 Revised Date: Draw Class: SHOP Pert Numier Part Class: Prco. Category: A.T.W. qY Seriesrhloeel: PA -3 APPROVED AS COMPLYING WITH THE SOUTH FLORIDA BUILDING CODE OAT L64.• 217-Z do PRODUCT C TROL DIVISION BUILDING CODE COMPLIANCE OFFICE ICCEPTANCE NO. _9__2 — /2 Obi T M WINDOW / AND DOOR Pompano Beach, FL. Item: • PA -3 ASSEMBLY DRAWING Sheet: 1 OF 1 j Orawing Numt t PA -SASS lf?evi:ios Level: / IRALIE co / /� �. / //% �` / aft T_ c U c r 1/4" SPACING I✓; -J,: t r 1/4" SPACING 11AX. 1 / SHIM AS REOUIREO r 1 /4" SPACING MAX. 2X BUCK VERTICAL INSTALLATION 3/16" DIA TAPCON 1 1/4 EMEEDMENT MIN. SHIM AS P.EOUIRED 1X BUCK VERTICAL! NSTALLATION 2" x F.T. W003 EL'C< 1 — X P.T. WOOD BUCK a Q O® RICO (1.1 Ill t #10 P.– 1 1/4" E',1EED u: . SHIM AS REOUIRED 1 /4 SPACING BUCK DIMENSION FRAME O.S.M. E3 1/4" !4 "TYP. MAX. -- { 1X BUCK HORIZONTAL INSTALLATION PA -3 AWNING ELEVATION! I A, 1 1 W1 11 ,. 1 al a ' D 1 v Revis:cns hlaterial DESIGN PRESSURE RATING (POSITIVE) =40.67 DESIGN PRESSURE RATING (NEGATIVE) —40.671 Orawn By: MH Date: 2/31 Revised Date: Draw Class: SHOP Pert Numier Part Class: Prco. Category: A.T.W. qY Seriesrhloeel: PA -3 APPROVED AS COMPLYING WITH THE SOUTH FLORIDA BUILDING CODE OAT L64.• 217-Z do PRODUCT C TROL DIVISION BUILDING CODE COMPLIANCE OFFICE ICCEPTANCE NO. _9__2 — /2 Obi T M WINDOW / AND DOOR Pompano Beach, FL. Item: • PA -3 ASSEMBLY DRAWING Sheet: 1 OF 1 j Orawing Numt t PA -SASS lf?evi:ios Level: / IRALIE PRODUCT CONTROL NOTICE OF ACCEPTANCE MIAMI -DARE COUNTY, FLORIDA . METRO -DADE FLAGLER BUILDING BUILDING CODE COMPLIANCE OFFICE METRO -DADE FLAGLER BUILDING 140 wES'r FLAGLER STREET, SUITE 1603 MIAMI, FLORIDA.33130 -1563 (305) 375 -2901 FAX (305) 375 -2908 • Gopi Glass Sales & Set-vices Corp. CONTRACTOR LICENSING SECTION •7450 NW 41 Street (305) 375 -2527 FAX (305) 375 -2558 •Miami FL 33166 CONTRACTOR ENFORCEMENT SECTION (305) 375 -2966 FAX (305) 375 -2908 PRODUCT CONTROL DIVISION Your application for Product Approval of: / (305) 375 -2902 FAX (305) 372 -6339 . Aluminum Fixed Window Under Chapter 8 of the Code of Miami -Dade County governing the use of Alternate Materials and Types of Construction, and completely described herein, has been recommended for acceptance by the Miami -Dade County Building Code Compliance Office (BCCO) under the conditions specified herein. • This approval shall not be valid after the expiration date stated below. BCCO reserves the right to secure this product or material at anytime from a jobsitc or manufacturer's plant for quality control testing. . . •If this product or material fails to perform in the approved manner, BCCO may revoke, modify, or suspend the use of such product' or material immediately. BCCO reserves the right to revoke this approval, if it is determined BCCO that this product or material fails to meet the requirements of the South Florida Building Code. • • The expense of such testing will be incurred by the manufacturer. Acceptance No.:99- 0629.01 Expires:09 /07/2002 Approved: 08/19/1999 Raul Rodriguez Chief Product Control Division THIIS IS THIE COVERSIIEET, SEE ADDITIONAL PAGES FOR SPECIFIC AND GENERAL CONDITIONS BUILDING CODE & PRODUCT REVIEW COMMITTEE This•application for Product Approval has been reviewed by the BCCO and approved by the Building Code and Product Review Committee to be used in Dade County, Florida under the conditions set forth above. 'rancisco Quintana, R.A. Director . 1 of 3 Miami -Dade County; Building Code Compliance Office 4. INSTALLATION . • Gopi Glass Sales '& Services Corp. ACCEPTANCE No. : '99-0629.01 APPROVED AUG 1 9 1999 ' EXPIRES September 7, 2002 NOTICE 01? ACCEPTANCE: STANDARD CONDITIONS SCOPE This renews the Notice of Acceptance No. 97- 0721.05, whiFh was issued on November 13, 1997. It approves an aluminum fixed window, as described in Section 2 of this Notice of Acceptance, designed to comply with the South Florida Building Code, 1994 Edition for Miami -Dade County, for the locations where the pressure requirements, as determined by SFBC Chapter 23, do not . exceed the Design Pressure Rating values indicated in the approved drawings. PRODUCT DESCRIPTION .1 The Aluminum Fixed Window and its components shall be constructed in strict compliance with the following documents: Drawing No. W97 -11, titled "Gopi Picture Windows," prepared by Al- Farooq Corporation, dated June 24, 1997, Sheets 1 thru 4 of 4, with revision A dated 10/31/97 on Sheet 1 of 4, bearing the Miami -Dade County Product Control Approval stamp with the Notice of Acceptance number and approval date by the Miami -Dade County Product Control Division. These documents shall hereinafter be referred to as the approved drawings. 3. LIMITATIONS 3.1 This approval applies to single unit applications only of interior or exterior single glazed, aluminum fixed windows, as shown in approved drawings. • 4.1 The aluminum fixed window and its components shall be installed in strict compliance with the approved drawings. 4:2 The installation of this product will require a hurricane protection system, • 5. LABELING 5.1 Each panel shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved ". 6. BUILDING PERMIT REQUIREMENTS 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance. 6.1.2 Duplicate copies of the approved drawings, as identified in Section 2 of this Notice of Acceptance, clearly marked to show the components selected for the proposed installation. 6.1.3 Any other documents required by the Building Official or the South Florida Building Code . (SFBC) in order to properly evaluate the installation of this system. Manu Perez, P.E., Product Cont Pmrl, nI- itrnl l�ivieinn 'Examiner • • Gopi Glass Sales & Services Corp. ACCEPTANCE No. : 99- 0629.01 AUG 1 9 1999 APPROVED EXPIRES : September 7, 2002 NOTICE 01? ACCEPTANCE: STANDARD CONDITIONS Renewal of this Acccptancc (approval) shall be considered after a renewal application has been filed and the original submitted documents, including test - supporting data, en documents, are no older than eight (8) years. 2. • Any and all approved products shall be permanently labeled with the manufacturer's name, city, state, and the following statement: "Miami -Dade County Product Control Approval ", or as. specifically stated in the specific conditions of this Acccptancc. 3.: Renewals of Acccptancc will not be considered if: a. There has been a change in the South Florida Building Code affecting the evaluation of this product and the product is not in compliance with the code changes. b. The product is no longer the same product (identical) as the one originally approved. c. if the Acccptancc holder has not complied with all the requirements of this acceptance, including the correct installation of the product. d. The engineer who originally prepared, signed and scaled the required documentation initially submitted, is no longer practicing the engineering profession. 4. Any revision or change in the materials, use, and /or manufacture of the product or process shall automatically be cause for termination of this Acccptancc, unless prior w ritten approval has been requested (through the filing of a revision application with appropriate fee) and granted by this office. 5. Any of the following shall also be grounds for removal of this Acccptancc: a. Unsatisfactory performance of this product or process. b. Misuse of this Acccptancc as an endorsement of any product, for sales, advertising or any other purposes. 6. The Notice of Acccptancc number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the Notice of Acccptancc is displayed, then it shall be done in its entirety. 7: A copy of this Acccptancc as well as approved drawings'and other documents, where it applies, shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at all time. The engineer need not reseal the copies. 8: Failure to comply with any section of this Acccptancc shall be cause for termination and removal of Acccptancc. This Notice of Acccptancc consists of pages 1, 2 and this last page 3. END OF THIS ACCEPTANCE Manuel P rcz, P.E., Product Control miner Product onjrol'Division I•. i 1 •. I 'r.:.': i t ' IM / /J � TYP:':.• 1 2 ' AVG. '. SPACING ..�: • TYPICAL •.- FALSE HUNTINS •(SURFACE APPLIED) HAY.:BE'USED AORB • DIM. FRAME `GG • WINDOW _ 6063 -T5 GLAZING STOP 6063 -T5 — T. 500 .500 �- - 41-- -. 062 FRAME O.G. WINDOW 6063 -T5 062 TYP ` 2 A OR 3 DIM. A OR B DIM. TYPICAL ELEVATIONS NOTES GLASS 3/16'. ANNEALED 1/4' ANNEALED OR 3/16' TEMPERED } . THIS STRUCTURE I5 .DESIGNED AS PER 'TiE SOUTH FLORIDA BUILDING CODE 1994 EDf1TON FOR DADE. COUNTY.• ALSO FOR WIND. LOADS AS PER. ASCE '7 • USING CORRESPONDING LOADS.. . • WOOD BUCKS BY. OTHERS, MUST. BE ANCHORED PROPERLY TO TRANSFER -_ . LOADS :TO THE STRUCTURE. :• • :: ' ".::••••• • • 3.: / ANCHORS SHALL BE AS • USTED,` SPACED . AS~ SHWN O ON DETAILS.- ANCHOR EMBEDMENT TO' BASE. MATERIAL. SHALL' BE BEYOND WALL •.': DRESSING _OR STUCCO.. USE IMPACT RESISTANT SIiU't'i'LrRS AS REQUIRED Y B. ..SFBC.: A.OR B DIH. A OR B DIM. ALLOWABLE LOADS FOR ALTERNATE SHAPES AS SHOWN ABOVE • CAN BE VERIFIED BY INSCRIBING PICTURE WINDOW SHAPE WITHIN SQUARE OR RECTANGLE AS SHOWN IN DOTTED LINES' AND OBTAINING ALLOWABLE LOADS FROM THOSE SHAPES, PROVIDED PERIMETER FASTENERS ARE AS DESCRIBED HEREIN FOR SIZE AND SPACING. PRODUCT \ ` RENEW GLE LITE PICTURE WINDOWS ACCEPTANCE No. - 9 (`k ` 9 -0 EXPIRATION DATE 1tc4.L.I DUCT CONTROL DIVISJO :_gp3DE COMPLIANCE OEEiCE , • Enyr. DR. HUVAYOUN FAROOQ STRUCTURES - FLl PEI 16557:' APPROVED AS _ COMPLYING WITH THE SOUTH FLORIDA BUILDING CODE • DAT I 9� PRODUG�C 0TY,SiO- : BUILDING -. CODE . COMPLIANCE: OFFICE AC NO, 6 ;17 7 -0'7 N O N .> 0 EL. 0 111 o f a) ro O l5 0 N a drawing n W97 -1 sheet 1 of •,' it 10 SMS DR .:. :• 3 /16'x2-1 /4'..TAPCON .. E 6'. FRL114' ENDS b 12' O.C.. TYP.:'. - MAX..: . # 10 SMS OR • • 3/16'x2 -1/4' TAPCON € 6' FROM ENDS & 12' O.C. TYP. • 1 BY OR • 2 BY .. .WOOD BUCK 1/4' MAX. • SHIMS DUCT CONTROL DIVIS IO •G CO . COMPLLA1'CE APPROVED AS COMPLYING WITH THE SOUTH FLORIDA BUILDING CODE ..: DAT 1 1) E 3 14q B PROD ' ONTRQL O MS • °" BUILDING CODE COMPLIANCE OF ?I _( � ACCEPTANCE NQ..----- - I0 SMS OR 3/16'x2 -1/4' TAPCON- 6' FROM ENDS t. . 12' O.C. TYP. GLASS AS PER TABLE 3/16'- ANNEALED 1/4' - ANNEALED 3/16'- TEMPERED Li BY OR 2 BY WOOD BUCK 1/4' SHIM L 1 10 S.}.i.S. 0 12' 0.C. DADE COUNTY - APPROVED MULLION - & MULLION ANCHORS ( J . • 3/16'x2 -1/4' TAPCON - E 6' FROM ENDS 1. 12' 0.C. TYP. PI A 4C 1/4' SHIM z.• V INSIDE GLAZED WINDOW OUTSIDE GLAZED WINDOW GLASS AS PER TABLE 3/16'- ANNEALED 1/4' - ANNEALED - 3 /16'- TEMPERED WOOD BUCKS NOT BY GOPI,' MUST-SUSTAIN LOADS: IMPOSED BY GLAZING SYSTEM •• AND :.TRANSFER THEM TO THE BUILDING STRUCTURE. ` = TYPICAL ANCHORS ,TO BE :.AT 6 ": FROM CORNERS • AND :12" SPACING., :: " . ` `. :.:... FOR •1" BY • BUCKS • 3/1 6 : TAPCONS ONLY, 1 -1/4 "MASONRY. EMBEDMENT .FOR 2 BY BUCKS - . # 10 SMS WITH 3/4" WOOD EMBEDMENT 3/16" TAPCONS WITH 1" WOOD EMBEDMENT 10 S.M.S. 0 12' 0.C. DADE COUNTY APPROVED MUWON & MULLION ANCHORS • # 10 SMS DR 3/16'x2 -1/4' TAPCON E 6' FROM ENDS . L 12' 0.C. TYP. PRODUCT RENEWED ACCEPTANCE No. t t D to 1 -c-A - b I EXPIRATION DATE S.tp i, 0 BY i1 PR •. BUILD c 0 E Z 0 co 2 w a._ O F' U M • O 5 O O0G CD 0 0 b 0 • rowing r W97 sheet 2 of DESIGN . :LOAD. CAPACITY: - 10 • SMS) WINDOW. DLMS... : 19 -1/8 ". 26=1/27 37 53-1/8". 19-1/8" 26-1/2" 37" 53-1/8" 19 -1/8" 26-1/2" 37" 53-1/8" 19 -1/8" 26-1/2" 37 53 -1 /8" 19 -1/8" 26-1/2" 37" 53 -1/8" A/B .: 38. -3/8" 50 -5/8" 63" 74 -1/4" ANNEALE 77.9 :;; : 57.3 '._ 57.3: • 56.8 ..':. - "77.7 56.2 - - 40.3 38.8 72.0 56.2 40.3 29.4 68.8 53.3 40.3 51.3 40.2 '.' I : x. 77.9 . `. 57.3 ' :: 57.3 56.8 77.7 56.2 40.3 38.8 72.0 56.2 40.3 29.4 68.8 - 53.3 40.3 67.0 67.0 51.3 40.2 ANNEALED XT. :..88.3- .=::<. .76.7.. 104.9 86.6 62.0 59.8 97.1 77.0 62.0 45.3 92.9 72.0' 57.7 43.2 90.4 69.2 - 54.2 INT. .:109.2 •': 80:3. ' 80.3 76.7 :. 104.9 78.8 56.4 54.4 97.1 77.0 56.4 41.2 92.9 72.0 56.4 39.3 90.4 69.2 54.2 3/16" - TEMPERED EXT.':. :: 110.0 ' . . 10.0 110.0 110.0 110.0' 110.0 97.6 90.7 110.0 110.0 94.7 71.3 110.0 106.3 85.1 67.9 110.0 102.2 80.1 65.2 INT, 109.2 80.3 80.3 80.3 • 109.2 78.8 56.4 54.4 109.2 78.8 56.4 • 41.2 '10912 78.8 56.4 39.3 109.2 78.8 56.4 39.3 SINGLE LITE PICTURE WINDOW COMPARATIVE ANALYSIS CHART BASED ON HETI -96 -1061 OF 10 -09 -96 QA TEST SIZE =. 37 -1/4" X 74 -1/4 - . TEST. LOADS = +60.0, -60.0 PSF' DESIGN LOADS = +40.0, 40.0 PSF WATER INFILTRATION TEST 20 PSF TESTED GLASS = 3/16 :•= ANNEALED 0,-.TEST SIZE = " 51 ". X 74 -1 /4" TEST .LOADS = +68.0, -75.0 PSF • DESIGN LOADS =. +45.0. -45.0 PSF WATER INFILTRATION .TEST = . 20 PSF TESTED GLASS = 1/4" - ANNEALED BASED ON FTL -1162 OF 6 -1 -95 TEST SIZE = 59 -1/2" X 77 -1/2" TEST LOADS = +91.0,`. -91.0 PSF DESIGN LOADS = +60.7, - 60.7PSF WATER INFILTRATION TEST = 16.5 PSF TESTED GLASS = 3/16" - TEMPERED :WINDOW DIMS. :. A/B : A/$ 24 " 36 48" 60" 24 " 36" • 48" 60" 4 " 36" EXT. INT. 95.6 94.2 . 83.7 78.5 87.0 87.0 83.7 78.5 EXT. :... . : INT. •110.0 110.0 110.0. 110.0 - 87.0 87.0 87.0 - 87.0 24" 36" 48" 60" 24" 36" 48" 60" 24" 36" 48" 50" 24" 36" 48" 60" 24" 36" 48" 60" 24" 36" 48" 60" 24" 36 48" 60" 48" 60" 72" 84" 96' 108" 120." DESIGN LOAD . CAPACITY PSF (# . 10 SMS) 3/16" ANNEALED - • 1/4" EXT. -'S • : INT'. . 62.1 62.1 . .62.1 62.0 : ' 58.1 . .. • 62.1 : 41.4 -'41 :4 41.4 62.0 41.4 31.0 31.0 58.1 41.4 55.8 41.3 54.3 49.9 44.3 62.1 - 62.0 58.1 62.1 94.2 41.4 63.8 41.4 63.8 41.4 . 59.8 62.0 83.7 41.4 31.0 31.0 58.1 41.4 55.8 41.3 54.3 49.9 44.3 63.8 47.8 47.8 78.5 59.8 47.8 38.3 75.3 55.8 47.1 73:2 53.3 71.8 47.9 42.5 58.8 75.3 110.0 ANNEALED . 3/16" TEMPERED 87.0 110.0 58.0 100.3 58.0 98.8 58.0 88.3 83.7 1 10.0 58.0 98.8 43.5 75.2 43.5 75.2 78.5 110.0 58.0 88.3 43.5 75.2 34.8 • 60:2 55.8 82.4 43.5 69.5 60.2 73.2 108.1 53.3 78.6 64.9 71.8 105.9 47.9 76.0 61.8 65A 65.4 104.3 42.5 74.1 58.8 103.0 72.7 87.0 58.0 58.0 58.0 87.0 58.0 43.5 43.5 87.0 58.0 43.5 34.8 87.0 58.0 43.5 34.8 87.0 58.0 43.5 87.0 58.0 43.5 87.0 58.0 87.0 58.0 PRODUCT RENEWED ACCEPTANCE No. t' 9 9 L .ci • 0( £}CP ' TI ON DA•I E . >w>..•� =20 • PR t3UILD Id' '0 w. UCT CONTROL DIVISION DE COMPLIANCE OF cE■gr: OR. HUAMYOUN FAROOQ STRUCTURES FLA. PE. 15557 .1 1 2PROVED AS COMPLYING WITH `: THE 6DUTH FLORIDA OIL CODE DAT >• tl . :.' : 194 `7 PRODUC ONTROL D11'aS.ON BUILDING CODE • F COMPLIANCE , OF ICE / ACCEPTANCE HO. -17 -t 7 1 4- 0 0 .� U c drawing W97- (sheet 3 c