Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
802 NE 100 St (4)
c•I•v•I•L E•N•G•1•N•E•E•R M. I. S. Corporation. 10221 Southwest 16th Street Miami, Florida 33165 Project: Dear Sirs; LG ENGINEERING SERVICES, INC. Consulting Engineers 2020 Northwest 7th Street Miami, Florida 33125 Tel: (305) 649 -6454 Fax: (305) 541 -3298 TILE UPL1F_LTES3 Carter Residence 802 Northeast 100 Street Miami, Florida Information provided by client: Permit Number: 49088 Date Completion: July 5, 2001 Roofing Contractor: M. I. S. Corporation LG Engineering Services, Inc. Project Number: LG01 - 1270 (Testing Laboratory Certificate #00- 0224.07) Tilly 9 2001 In accordance with your request and authorization, a representative of LG Engineering Services, Inc. completed the Roof Tile Uplift Test at the above referenced project. This testing was performed in general accordance with Roofing Application Standard RAS No.106 -- Standard procedure for field verification of the bonding of mortar or adhesive set tile system and mechanically attached, rigid, discontinuous roof systems. The total of the tested roof surface area was less than 5000 square feet, and the mean height of the roof is less than 30 feet above ground surface. The type of tile used for this project was reported to be Altusa Roof Tile. This tile was reported to have been foamed in place. At the time of this testing, one test for every corner, one test for every 100 square feet of roof tile in the perimeter area and one test for every 200 square feet of roof tile in the field area were tested. Initially the entire area of the roof was examine for loose tile. More than 10% of the roof tile located in the field area and more than 20% of the roof tile at the roof perimeter and corner were physically examined. Based on our test results, we conclude that the installat on of the roof tale at the above referenced project meet the test requirement outlined in theabove mentioned protocol Attached please f ind a copy of our test report for your r LG Engineering Services, Inc. appreciates the opportunity of assisting you in this project. If you have any questions or if we may be of further assistance, please do not hesitate to contact the undersigned. Respectfully submitted; LG Engineering Services, Inc. oha ad Sonny Sa11eh;`': roject Manager • - TILE _UPLIFT TEST Carter Residence 802 Northeast 100 Street Miami, Florida Report of TILE UPLIFT TEST for Carter Residence 802 Northeast 100 Street Miami, Florida Project Number: LG01-1270 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 Test •S(atLIS Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass LG Engineering Services, Inc. -- Tile Uplift Test Result -- Project Number: LG01-1270, Page 1 est Number 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 Test Load (lbfj; 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 tatij Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass LG Engineering Services, Inc. -- Tile Uplift Test Result -- Project Number: LG01 -1270, Page 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 62' 55' 44 1 5 8 5 7 6 8 90 4 45 49 45 47 48 46 55 56 57 42 41 59 55 29 52 2 8 51 27 26 25 17 19 6 50 20 21 9 22 10 11 25 12 24 15 14 15 AFP} OXIMAT g51" LOCATION 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 PERMIT ►► AAPPLICATION FOR MIAMI SHORES VILLAGE Dates lE a ��r / pp ob Address p9� ,V 4 Tax Folio Legal Description Historically Designated: Yes No Owner/Lessee / Tenant F/2- •4 A/ 57$ C I 7 jL Master Permit # -< p OS? Phon& 06 J 7 Owner's Address 8Dc9 AV"'/2© 61- Contracting Co. -` &c eya . Address /o7 2/ �(.J 6 S, //01/ ,Tv re `e-6 G , —�✓ r" SS# / � -�� � Pho � t� /s� /<c% . Qualifier State # G GC x'758 Municipal # Architect/Engineer Bonding Company Mortgagor Address Permit Type (circle one) - :�BUILDING ELECTRICAL PLUMBING MECHANIC ROOFING : AVING FENCE SIGN WORK DESCRIPTION 7 /l am 64) ai-0-.40' Square Ft. WARNING TO OWNER: YOU MUST RECORD A NOTICE OF COMMENCEMENT AND YOUR FAILURE TO DO SO MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY (IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.) Application is hereby made to obtain a permit to do work and installation as indicated above, and on the attached addendum (if applicable). I certify that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that separate permits are required for ELECTRICAL PLUMBING, SIGNS, POOLS, ROOFING and MECHANICAL WORK. OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Furthermore, I auk rize the above -named contractor to do the work stated. My Commission Expires: FEES: PERMIT RADON Date Competency # Address Address Estimated Cost (value) Ins. Co. - -- r��'• ;f irer M Grim , . 61/03 _ U003 11 Persplayy May,: ; , oth Notary as to Contractor or Owner - a ui d My Commission Expires: C.C.F. NOTARY V BOND 3PP Date APPROVED: Zoning Mechanical Plumbing Structural Engineer TOTAL DUE Building 517 ectrical A RECORDED COPY MUST BE POSTED ON THE JOB SITE AT TIME OF FIRST INSPECTION PERMIT NO. TAX FOLIO NO. I `) "4O tQ `- 'V 9 ) 4 - D lJ ( 6 STATE OF FLORIDA: COUNTY OF DADE: THE UNDERSIGNED hereby gives notice that improvements will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement. 1. Legal description of property and street address: i*ot !/!/ 'i> ' 1 , 6 /76Asos 3 3 / 3k' 2. Description of improvement: /' P -7 4 1 7 %e /Ue`e 640/7-, u, 3. Owners name and address: `s4 itt✓G / 5 e III Wit- f' 02 .0 / / : A 3 3/3 ' Interest in property: yD1L17'r /e l - i 4»» F 0 l7 Name and address of fee simple titleholder: 4. Contractor's name and address: 5. Surety:(Payment bond required by owner om - contractor, if any) /V/ IV Name and address: Amount of bond $ 6. Lender's name and address: 7. Persons within the State of Florida designated by Owner upon whom notices or other docum-nts may be served as provided by Section 713.13(1)(a)7., Florida Statutes, Name and address: 8. In addition to himself, Owner designates the following person(s) to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b), Florida Statutes. Name and address: 9. Expiration date of this Notice of Commencement: (the expiration date is 1 year from the date of recording unless a different date is specified) Signature of Owner �(/ Print Owners Name r 4)1/c- S C 1471 14 e. Sworn to and subscrib Notary Public NOTICE OF COMMENCEMENT Print Notary's Name My Commission Expires: • .cam% s 40o- STATE or f LORIDA, COUNTY or DADE anginal I I HEREBY CERTIFY that this Is ltrue or the iv" l day or 11 1 1 TNESS my hand a t' li I Seal. HARVEY RUVIN, C RK, .,` /I 'cuit and County Courts n this office on 0 1R:253637 2001 MAY 17 15;;51 x' '17 iyrt ...N• , curs \ 123.01-52 2193 Prepared by: Address: er7L /c9 r ,2'-r/' / 47 --z % —Lr 3 / 5 744 to Ja Contractor's Name: ❑ (Low Slope Application) ❑ (Asphalt/Fiberglass Shingles) ❑ New Roof Flat Roof Arca (ft 366 Exposure category (per ASCE Appendix "E" UNIFORM ROOFING PERMIT APPLICATION PROCESS No. ROOF CATEGORY ❑ (Nail -On Tile) ❑ ( Metal Roofs \Wood Shingles & Shakes) ROOF TYPE Cl e- roofing ❑ Recovering ❑ Repair �3 S f a- a Sam Sloped Roof Area (ft eZ gi Total (ft _ may -88): C Building Classific Lion category (per ASC Job Address: (e42 ,j /1?): • n aA s il -e-- ROOF H P � � , „ i d r a w ,,F1,6444/ plae-14 6110t/POV e 3&" e+' / IIi9 Ft. V Fastener Type: ATTACHMENT Field: 12 Perimeter: jr SPACING Corner 123.01.78 9/96 DETAIL 1 (tic 2 EIGHT AND SYSTEM DETAILS details as needed) M Page - I r f�riao.5 ❑ Maintenance cz7S 729 - Master Permit No. 7 -88 table 1): _.L. I r. 1 I I I I e (Mortar - Adhesive Set Tile) ❑ (Other) 7: • -4I man /O Deck "nc 1 It vim-= �1 . , (27 - 7; 4 1 15 ?,1d. 5 � t c g - I 441 44a- a a 7 A i 6 s NO Aplomb* "2" UNIFORM! ROOFING PERMIT APPLICATION PROCESS No rammer _ t o e * + /2 ,c../ / Wa.:. ,,. Cop f#.w: IS - 44166,+< fie!! !e ✓l �J�� ���`�y Rost c.•.ras A 4101C moor nese Page.2 •T3Nt,HZ d ir DAP moor %i0}4. j • ATTACHMENT! REQUIRED 1) Pico Outcry Lisang Page 2) Dads Carry Product Control Noticed Acceptance-Cora Shea a) Specific *mew Description b) Spero Syrian Limitation e) Omen! Limitations d) Applieble Detail Dra 3) Municipal Permit Application 4) *ha Composed Ancona: initriihrilaanali (Piro 1:4abL. it L to ro•oisii. M+tawkwr -274 ) . M s js =M 718 PCB►: Cestor2:41i a A. tarwr.a.. - ' mawd: x A. (a.94..u..i. Mdikriary ) • M jr___ `Ma: /al PCA: __IL ( 4t 1 11 1.46 .tA,a aCA 1 1 \PPFNflEX "F" r.re )1 r•11t. "NEfbS N CTr'.1Ttnl\ CnP ROnFfNC: CONSIDERATIONS Ir`•• :I...7. _ ' : I ; •: •l.-r.lr r e-, rr,N, n•tr- r;,r` •1C. c. •Irll rile- f \t As it pertains to till, �tF,NG+I , , . ;, :.. :.�Y�;..,...,, :J .:; ..:_ ._•r ... �� ..�•....: - %:: ;;;;17.:;'..-..:::: r. 4 re-. . rt , rn rl, � ,-,. ,,re- r t , , , rnl,r. r (.F rt.ie required roorui� pcculi�, iv pi �,. ,iii iuC v: :u�: .. uu ,: u.. .7:n."2 _`' -. • .. . r . C , . •_ -- _r L. r_ FI,_ :.r_ c., rl' ( 4,. lc , •n. - rri, III fltr minimum torn(. Tilt: pro. iiiv+,� yr . fiia . J� vI .... . -..r. :r _ - - . r . '.-- :_ _ _ _ r'_ _ II,r:n,. A.ir1;rir r ttv rI - lnlln.cinr• ;tr.-.11,c requirements aflU �iailU:�fO� v, �iil n,t....� „ � ,:., ,._ ..,,,..� ��-..._... :.. _ i......_... .L _ 7.......7.7.7 .t !L:. '-'...!....'.r.7.-21...--. Th nit•n: r'c ltlifi: l in rile- - ' � aI L,I VC,`•CCI. - ” should De aaoresscu a> p:,it of site ,.,� .... ..._ __ _. ... , adJaecIl( DON indicateS that tnc tic+n ita, ucCil c.:l7taiflca. r kit) 1 _ `i• C_Tha_.... j _ l - Il,n I,rnnen ni t\csUic(ics- ii Tile workmanship p:i, \lnwn� "..p• -• • - . ... y -� !-•-. .. providing (ha( the rooting system n1ect5 rile winds rc5 +SWn C ailii �iLr iO" j• i % - - s • , ^ •• I -- Aestheticc (appcarancc) issues are not a consideration with respect io • or',..n , ;!; , :l. ::eir_ such as color or architectural appearance. that are not part of a zon i ocl , sl S. . a.; Y,rt . f th- acreenIent between the owner and the contractor. C_ 2. Rcn•liling Wood I)ccla: roofing. ltcn replacing roon�, the c.�ul wood Ju �n :,i n iL.. ; : 11: � r, b‘: C :2 r..:._:, ' r•.. , 1 1, t in accordance with the current provisions of ChapCCr 29 of (he SrtaC. (tile roue r ,Lie - i; us: :::.1 ccocc: : ::a_Y. ....-,r :. remove g the a 'sting root system) t(02__ 3. Common hoofs: Co:union rooy`s are those tt91ic11 have no visible d,liner,tion oe(tvecn ttci hc,orin ti nts (i.e. tot•nhouses. condominiums, eta.). In buildings with common roots. the rooting contractor andror c.snrr should norify the occupants of adjacent units of roofing word: to he performed. Ca l... 4 E~,:nosed ceilin?s: Exposed. open In.:ilm ceilings are where the underside of the roof deckin t can be :-,3 from below. The owner may wish to maintain the archiceccurcl app_arancc, dhCrforc, roollll naii rrra■; or rlie underside of the deckinc. rn: t not b•. acceptable. The SF SC provides the option of tttaintoining n nrprant•r oni. \\r;ltrr: The cttrrcnc roof syst•_ni andlc•r deck of tlic building m; y not drain %veil and ntay taus. tiv h ac ^ L•: : pcOd (cc' .!tll in low I arCnF of tSe roof. Ponding can be :tit indication of structural :. r l,r r o r , prof =: <ion I structu::ll cll;illcer. f oncliri may shorten the life GI }irs: .:,lu iii:. j r_aL.� C fo of tl•.•_ lttt•.' rt s :r:ol, Pridilli' eon:llicit:ins may not be evident Lilian the ortziIl l t:. \LJ Cia ll.y' .:1u i', =11,:, r"lan�_ roo(t1E $y'S:C+tl i r d. fated: coon:lido :1F, cl b^ co rrccred. .c, r: s not 6. Overflow JCt1I1f (+'•':..I v'::act >): Ic ,- .ti ^l +irr_d (ha( rainwater flc, off so 1111( the loos t. r f . P .-,I4 or o tl t rr roof i.letlitonS may Hoek this discharge if Over oadcil 1rUnt a guild up of t�.tt_o r. , a.,i.�,_.�._.�v ... O overflow scuppers (t.'aii oticik(s) ace. i1C1: } ' , rove - id _:+. I: n17. : y I^ ntcess ?n• to illjtall overflov. i scuppers n accird hcc tt ith Chapcer 2 of die Si arc. 1. l 11:c.::::;..:;:71- ..t,i!ir,• In vr ;n.f. natu ral airflow (ltrou the interior 7, ventilation: trioa fooC s(ructur:i Stioillu z •• -r, ,, .r ,t_ci,_ ventilation shall not b: reduced. It Of (hc structural assembly (cite building tCScif j. i iii: C:iijitt:_ ::t7;v,..C: r _ . .,.r :•,., rl,.:• c,- rvl. :c life of the roof. 1 ' be beneficial to CoitSideC ;tdditiJnal vclt(in` ■�'iucil c;i+: iiisu.. I•:.::::,._. � � - - r . C.•r i nc,n lrt.ml nt for further S. Tilt owner may contact the 1Vriatnl•DauC Couu(� „ =r information rc trdirt� the above. Ol•ncr s /A:cnt's Signatt rc r- �rnr c;,enatl MIAM PRODUCT CONTROL NOTICE OF ACCEPTANCE lrnur (USA), 664; Uw 7: Ave. Miami A pprOvvd :`�ZSloll! Eip•res;_tut/now FL 33166 Your appt.caagn for Product Approval of A fnsjn "s Tiff under Chapter $ of the Code. of Miami-Dade County governing the vie of Alternate Materials and Types of Construction. and Cotnpktely described herein, has been reconwnendect for acceptance by the Miarni -Dad•: County Budding Code Compliance Office (BCCO) under the conditions spec red herein. This approval than not be valid after the expiration date stated below. BCCO reserve% the right to secure thi product or materiel at anytime ftonl a jobsite or manuf'acturer's plant (Or quality cameo! testing If this product at material tails to perform in the approved manner. BCCO may revoke. modify. or susaend the use of such product or material immediately. BCCO reserves the right to revoke this approval. Ira is determtined BCC() that this product or ntarerial fails ro meet the requirements of the South Florida Bustdin; Code. The expense of such testing will be incurred by the manufacturer. Acceptance No.t99.1102.0* (Revises No.: 97. 091!.02) Raul Rod rrguee Chief Prodltet •.'ontrol Di•i),on TN IS IS � H COVERSHEET. SEE ADDITIONAL PACES FOR SPEC WIC AND GENERAL CONDITIONS `r !Etigi LDtNC CODE & PRODUCT REVIEW COMMITTEE Thisiiiiiiitajtionfor Product Approval has been reviewed by the BCCO and approved by the Building Co* and PeocWet Revte w�ZIii ttee - be used in Dade County. Florida under the conditions set fonh above ra ^ 1r.ntlltA. R A e Oireq ...J Naa'.. c County 0i..Idpsa6t;ode Compliance On. of 8 !11�►!rt -VAAE CA. :14Tv cLort•i . . +CTRO.04O£ rLACt -te Bti�t.A,'G alrLOs•(; COO.: tot++t+CJ.!Ct-Orrrct: •"CTNO•DAoc FL•etCa au "a a tsr FLALi.t r►' 114► fLentiO4 400 Ise) . 'of) )1)r. ?Ypt FAX ()Oil j COVTr+CT011 LICCSSINC AACTap% 1305. 333 -:3`1 sag i3o513Is.!s!t rpwfr4CTOa exemiteasent siC iM1) 3 P4* owl fl).rsea P t)OUCT CONTROL OiVISIO■ t IO S. 375 : +M : six 1305. 17:.6)).1 - AL All (USA). INC. 3. SCOPE TM revises a hooting system using Abner 'One Piece S' Cyr Alrtiae (%JSAL Inc. described in Setzthoa ? 404 Notice of with the SerMlt florid& Bolding Code, 1994 Edition 1br M locations where the pressure retorts. ss dessintaned k 2. PROD((CT DESCRIPTION One Parse 's• vita Thin ►stns o;0 Fee Root Tile. as atatwfscturcd past designed to comply Inn -Dade Cottony. For the SF$C Chapter 2;. 4o not ecceedi toe design pessswe values obtain by calculations is 4om1ohaace with RAS 1 ?7 guilt lilt Muss listed in section s Weie. The anaeAutteat al+latOons shall be dote as a ntonnetlt based system Cate: Prepared Roan* Sub Category: High Profile Tile eigadmittur agigiust 2.1 radio ACCEPtAvCE tv..:, 10i 0a APPROv4p Demobs. 14, 1499 EXPIRES I Dec,., 16, tat tPoY10E OF A rslrr STMIpAID i- 11 W w• t0' 'o+ thick nee oil 1 • warts i. *varies walvig g dick/mess CCoa■e...*s or psalms mann(act.red by often Disueillbs tWA agmissim Test ; ?sake, uggapien PAM Test as Cameo Mad NIA ASTat Onto Semn.s a ethd an*d Shaer organic tars sera simile or double I* High e* td ale Fa direct deck a NOM -e 1, tei Or adhesive sit aplitatiens. PA 112 Atpaaary a►aw. star root gorses for est es bits. foci rasps aM vapory Nv nwt� ,s Maa tt/&etefd for eeh t,ta male P tfigyolgurnt ASThf O 22d SSrfeter trrpic keg to ieetr.e type 11 be road at & o«lei Mbar shoo. 1 drat.. A(MIAR (USA). INC. ACCEPTANCE loo.: 99./10244 APPROVED -Det:ern 14, (99r EXPIRES .December 16, 2002 Mineral Storage Cap Sher Rainproof 1! Ice &Ad water Shield WWOQ eattani Trla Naas Tile Screws Product Roof Ti la Mortar ( "Tile NOT10E OF ACCE TANCE: aA1R *lien N/A 30` x7S' roll 36" a 73' roll or 60 " *7S' roll ;6" R 73' roll 'r wan. 4 sEues0M mm. 1 s 4' for aid wig. vertical bawls or nun. 1' x 3" for nit alone Min. 106 a i" a<t a ? Kielty 0.31S Mead dia. 0.131" sham dia. 0.173" stew. thread 4iainster N/A Test Saisifitar�mi ASTM O 249 PA 104 ST6NDARD CONDITCO Mineral surfaced atom ft • roll roofing for use ata top ph in a deubte ply undtrlayment system Sinileplr. mail.on Wedertayment with r selF adhering top edge PA 103 SeWadherins ut.dorlayment for use as a IS ply in a me pry underlaywuws system with Approved 130 Or 443 u the bast layer. WoW Po meets Sao immure treated or Institute LP - 3 decay rttsiuint lumber Wens Pit lea AppanO4s E PA 114 i►ptNtlO�s E PA 123 Cornesien niacin& snook screw es a nvIsr tine cuing sail. Csnesiee resitsand nicet severe drib,. galvaeiard. Marie *read mood screw Prepared mortar leis designed for mortar set roof tilt applications. 111.4•111.4.1111....46... Irlasnu faetarer Protect -O- Wrap. Inc with Curtest NOA W.R. Grace Co with C screens NO* =srlerrt CeAn se geeing B.vr yob Roof Company. Inc. (void* current NOA) ALAIAR (USA). INC. f t Qinttc•ese Roo( Tice Mener Rost Tile Adhes..e C'?+y1rat AN1401 Tits -0041 3. LIMITATIONS Menial NIA iaetory Premitted caniuns Test Alttfasplions giadgalOdd PA 1 !3 Pt epe ed enoeta+ wis desired le,r ligAer metrics piplisaiiois Sea PCA Two coutpontm polytweetiase deci`11y roof the the eel See PCA Smelt cmmpene.p po+y+uetheme Oa+t roof tilt adhesive ACCEPTANCE No. :_Ituauf APPRO% D • Member IC 1999 Duster 111, 20111 fialdniegt (Notions Mons (liuA omens NOA ) Potyfesen Products. inc. (.with settriewr NOA) Flexible Prxivets (w anent NOA) 1 Fire ctassiftcation is nog pan oldies aahtartce. 7g.2 For inestee or adhesive set lift applications. a static ;tie1d mph* test shall be performed is accordance with RAS 106_ 3 ; Applicata shall resin the services es Miami -Dade Co j,at, Certified Laboratory ro porfonn arena* sett in accordance wta PA 112, x 'A'. Such testing shall be svbosined to Ms 8wldin Code Compliance I� review 3 e Minimum wsderla)rrtsenas shall be to compliance with; the applicable Aoorn6 Appltea ion Standards lewd whom 4.1 herein. 3 S .0190 hot mopped uader4ymetu applications may be Omlied perpendicular r0 die roof slope unless stated otlsttwtse by die taderlaymai material mMefacawrts published I srstwt. 3 6 This aooeptaaes is for wood deck eppiicaeioas. Miniratemjdeck mquirentents shall be is caliphate with chapter 29 of Me SFOC 3.7 May be iagstled on slopes 7 ad grant. 4. INSTALLATION 4 1 Abaft "OW Piece Se Olay Roof Tile aid eft components s$ft be installed vn VIM esmOiianee wiet, Marne Dada County woofing Application Slam:aid RAS 11/. MS 119. and MS 120. ALM.aR (USA), 114C. ACCEPTANCE Ko.: 99- 102.09 APPROVED :December 16, 11!! EXPIRES :December 16, 2002 NQ=ICE9P ACCEPTANCE_ STANDARD CONDITIONS Rensw9l of this Acceptance (approval) shall be considered alley a reaews1 applicmion has been floe and die original submitted documents, ineluday ttst.supp.rei.`rata. etyiaserios documents. an no Older *en eight (1) bean 3 Any and all approved products shall be permanently labeled with be mentsfsetw,t's name. cif,. state. a$d die following staemsai: 'Mianti'Dade County Product Control Approver, or es spec ificlslly mated itHhs specific conditions of lids Acceptance. Renewals of Acceptant will not be considered if: a There bas been s change in the South Florida Su.Ning Cote sfseties the evaluation of this oepduce and else product is not in compliance With die sods did. es b. Ton product is as layer the same product (identical) as else on originally spooned. c. If !doe Acceptant holder lim not complied with 111 die togwvstnstts of dais eccepistice. ia$lttdiis die correct installation of olio pteduct. d. The =gin, be migitia117 pews& sired end scaled dm Iegoited do inns mtisu itiitesllr s.rpteiiteed, is no longer practicing eels eagiemering profession. e. Any revisipti Or calor in the materials, age. arWer Aansfacwts of the prods= Or pacers shall anasoma us Ity be ame for seenainatien of this Acceptance. eailess prier written apprroval has been ^so (MOW. shoe filing of a revision application %rith appropriate kg) end paned by this office. 3. Any eft f 'moods Olb�wiag shalt also be 'unds for .enema, of this Acceptance: a 'sfecery performance of this product or process. b M4iues of dais Acceptance as an endorsement Of arty prodttti for soles. advertising or any odtbr purposes. 6. The Not4ca of Acceptance number preceded by Me words Kam-Dade COusty. Florida. and followed by the espiretioa date may be displayed in adverting lirrastre If any potation of ohs Now= oVAcesp once is displayed. doss it dub be done in its entirely. f. A Copy of is Aceepsace as well as approved drawings and one doanneao, whew it applies. shall be to doe s+tsv by the tnaaufaeturet or its diwr+busors and shall bs svnil bls for in at they* an at all fine. The =sine: tank Aot reseal tie aspics. Faisute tq oewtp.y with any section of ibis Ac,csp soce shall be cause for econiiaeioa and removal of Accepyaco. 9. This Marie* of Acceptance consists of poses 1 them. 7 mad dlis IoM pass >R r •U. MAk (MSAL INC. PROFILE DRAwINGS Opt Pitta 'S' Ct.v Roos Du ACCEPTANCE No. . �t4., APPROVED :December 16. 1999 EXPIRES :December 16. 2002 • itaimes meenet ammo 1 rs.s. ALM aR (USA). INC. ACCEPT/ %C E N.. : 99 APPROVED December ti. 1999 EXPIRES - Member N. 2002 NO T_ C Of A 4! PTA STA CONDITIONS 4 2 0lata For Attachment Calculations Tablet 1: Aeree�rearnic McIliOliers - 4 (P 'File AtNh 2 1 Profile Batten Application Oiract Doe,_,Itooptieation One P 1Td J 0.2S; — 0274 IlEriARIN:21111111Efall maim IMAM tL7 Tile Profile OM exec S Tao T ibis 3: Attachment Resists Etsprsssed as • Hareem • 4 Magi for Nail-00 Systems Tile Fastener Type Direct Deck Thirect Deck flatten Profile Rein 15132" (min. 11032•• plywood) plywoodi Tale 2: es Moments due to .10 Ifl.tbf :1 1" :tF' S ":t2" 1%12 7':12"' os or less neater • sae.ws .es D ono Deoe Oea� Ow ttra tl.a 33 ea. ate' w nvaeu► •N 4prtiy oft %MON • wiw. er 2W AMe Mae et It +..wroir518579 ASC SUPPLY •ii)• Lw• uok WL D 1L 1 77:6110 April 25.2001 Mr. Bob Ferfa,te Polyfoam Inc. P.O Box l 1 2 Spring TX 353 -1132 Re: Two tomponent Polyorethnno Foam Adieulan +l Mo. 91- 0+00.01 Dear Mr. halite- This it to itif renewal Im final review hmc the N foott die Notice of Proposed Action for the above will be issued and MISS kb die Building Code and P product under c for said April 27, 2t)Ol _ We expect that that rev' Product Review Carnrrtittee for their of At eeptanee (KM) will be issued review will be completed within 20 daps. at which • letter we are amending the n of the P�I�aon date <b Jute I, 2008 to elac,a, the � Irk NO* front the original of to the NOA at time of permitting. final w time. Please attach a 99 -0423.01 Tw Cotoponent Pbtyuralhatc Foam wive This letter expires .hula 1, 2001. We hope this feel flee to t thjg office. should you require any further information on 0tis matter please Sin rely, By roans of Apnl I6, 2001 Copy of this Raul Rodrigues Chico. Product Control Division cc remise. J. Painteovi. R A.. Dimmer 916 Poi MAY 14 ' 01 10 :10 I4Crf+ eitun1 +-t r ltvronl . n1 MIAMI-DADE COUNTY, FLORIDA METRO -DADE FLAGLER 8lJn.D,Nc aurt,0lG CODE COMPLIMICE OFFICE • Ica WILSI't:t.ACLE* STER I. sung: I�Ot MIAMI. FLOifli »A 138141/63 oast 17,.2901 SAN (laS1175.390, raoDU I• t DNruct. investor., 1M!) 37S ran/ Fax (10/) N New expiration DOW Jtmtle 1.2001 rvennOrw rt,y, n Thi late wsit>rtc,q �.r • METRO ZIADE METRO -DADE FLAGLER BUILDING PRODUCT CONTROL NOTICE OF ACCEPTANCE Polytonal Products, Inc. 2400 Spring Stuebner Road Spring. 'TX. 77383 Your application for Product Approval of: 'olvfoam Products "Polvpro Alt - 160" Roof Tile Adhesive under Chapter 8 of the Miami -Dade County Code governing the use of Alternate Materials and Types of Construction. and completely described in the plans, specifications and calculations as submitted by: Thc Center for Applied Engineering, inc. and Miles Laboratories Polymers Division has been recommended for acceptance by the Building Code Compliance Office to be used in Dade County, Florida under the specific conditions set forth on page 2.14 and the standard conditions on page 15. This approval shall not be valid after the expiration date stated below. Thc Building Code Compliance Office reserves the right to secure this product or material at any time from a jobsite or manufacturer's plant for quality control testing. If this product or material fails to perform in the approved manner. the Building Code Compliance Office may revoke, modify, or suspend the use of such product or material immediately. The Building Code Compliance Office reserves the right to revoke this approval, if it is determined by the Building Code Compliance Office that this product or material fails to meet the requirements of the South Florida Building Code. The expense of such testing will be incurred by the manufacturer. ACCEPTANCE NO.: 98 0303.02 Renews: 96 0402.02 EXPIRES: 04/16/01 APPROVED: 04/16/98 Intornet mall addra•s: postmaster @buildingcodeonllne.com METROPOLITAN DADE COUNTY, FLORIDA BUILDING CODE COMPLIANCE OFFICE METRO -DADE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 MIAMI. FLORIDA 33130-1563 (305) 375 -2901 FAX (305) 315.2908 PRODUCT CONTROL DIVISION (305) 375.2902 FAX (305) 372.6339 aul Rodriguez Product Control Supervisor THIS IS THE COVERSUF.F.T, SEE ADDITIONAL PAGF..S FOR SPECIFIC AND GENERAL CONDITIONS BUILDING CODE COMr41TTEE This application for Product Approval has been reviewed by the Miami -Dade County Building Code Compliance Office and approved by the Building Code Committee to be used in Dade County, Florida under the conditions set forth above. Charles ()anger, Director. Building Code Compliance Dept. Miami -Dade County Nomepage: http :l/www,bulltlIngcodeonlln0.Com POLYFOAM PRODUCTS, INC. Applicant: Polyfoam Products, Inc. 2400 Spring - Stuebner Road Spring. Texas 77383 -1132 PRODUCT CONTROL NOTICE OF ACCEPTANCE ROOFING COMPONENT APPROVAL Contact: Pat Murray P.O. Box 1 132 Spring, Texas 77383 -1132 Phone: (713)350.1 Fax: (713)288-6450 I'agc 2 of 15 Product Control No.: 98- 0303.02 Product Control No.: 98- 0303.02 Approval Date: April 16, 1998 Expiration Date: April 16, loot Cocoon': Roofing Component Sub- Categgry: Fastening/Adhesive Tips Roof Tile Adhesive Sub-Type: . Two Component Polyurethane System Description Polyfoam Products, Inc., produces two- component expanding polyurethane adhesive for the attachment of clay and concrete roof tile. Polypro® AHI60 is specially designed for application of concrete a nd clay roof tile over a variety of roof deck substrates and underlaymeut materials. Polyproe adhesive is applied with proprietary Eoamprogi RTF 1000 dispensing equipment. Approval of this product is specific to the two component mix and Foampro® RTF 1000 dispensing equipment. Alternative methods of dispensing will require a revision to this approval. t'ulyproQ0 adhesive shall be applied only by 'Qualified Applicators', licensed by Polyfoam Products. Inc. Certificates and identification cards are issued to applicators upon successful completion of a application training program. Approval of this adhesive system is contingent upon application by a 'Qualified Appl icator. Frank Zuloagn, RRC Roofing Product Control Examiner Page 3 of 15 Product Control No.: 98- 0303.02 £OLYFOAM PRODUCTS, INC. TRADE NAMES OF PRODUCTS MANUFACTURED OH LABELED BY APPLICANT Test Product nfication De? L� ^ - oduct pi n ions �-^ —� Two component Polypro® AH 160 N/A PA 101 polyurethane Foatnpro® R I F 1000 N/A See Detail Attached Dispensing Equipment Frank Zuloaga, RKC Roofing Product Control Examiner POLYFOAM PRODUCTS, INC. Test Agency Test Identifier 'LEST REPORTS Center for Applied 1194 -060 Miami Dade Protocol 04 /08/94 Engineering PA 101 Center for Applied 257818 -IPA Miami Dade Protocol 12/16/96 Engineering PA 101 Center for Applied 25- 7438 -3 SSTD 11-93 10/25/95 Engineering Center for Applied 25- 7438 -4 SSTD 11 -93 10/25/95 Engineering Center for Applied 25- 7438 -7 SS - fD 11 -93 11/02/95 Engineering Ccntcr for Applied 25 -7492 SSTD 11 -93 12/12/95 Engineering Miles Laboratories NB -589 -631 ASTM D 1623 02/01/94 Polymers Division Ramtech Laboratories, 9637 -92 ASTM E 108 04/30/93 Inc. Southwest Research 01- 6743.011 ASTM E 108 11/16/94 Institute Southwest Research 01 ASTM E 84 01/16/95 Institute Trinity Engineering 7050.02.96 -1 PA 114 03/14/96 Page 5 of 15 Product Control No.: 98- 0303,02 Test Name/Report Date Frank Zuloaga, RRC Roofing Product Control Examiner Apr-30-.98 04:11P Po lyfoam Products inc. POLYFOAM PRODUCTS, INC. TYPICAL PIIYSICAL PROPERTIES 1'ruj�e rtv Density Compressive Strength Tensile Strength Water Absorption Moisture Vapor Transmission Dimensional Stability Tcs t ASTM D 1622 ASTM D 1621 ASTM D 1623 ASTM 0 2127 ASTM E 96 ASTM 1)2126 ASTM D 2856 86% Page 6 of 15 4 vi'-i -.vt- Product Control No.: 914- 0301.02 Results 1.6 lbs. /ft.' I A PSI Parallel to rise 12 PSI Perpendicular to rise 28 PSI Parallel to rise 0.08 Lbs. /Ft 3.1 Perm / Inch +0.07% Volume Change @ - F.. 2 weeks +6.0% Volume Change (c_41 58°F., 100% Humidity, 2 weeks Closed Cell Content Note: The physical properties listed above are presented as typical average values as determined by accepted ASTM test methods and are subject to normal manufacturing variation. Frank Zuloaga, RRC Roofing Product Control Examiner ikp r' v-+ . it . .-, .� .. �.... . POLYFOAM PRODUCTS, INC. rage 7 of 15 Product Control No.: 98-0303.0 SYSTEMS Deck Type: Wood. Non - insulated, New Construction /Rcroof Deck Description: 15/32" or greater, plywood or wood plank. SYSTEM A: Adhesive Set Application Slope Range: 2 ":12" to 7 ":12" Underlayment: Shall comply with Miami -Dade Roofing Application Standard PA 120 Roofing Tile: Any roof tile assembly having a current shall be applied in compliance with the Component Application section and the corresponding Placement Details of this Notice of Acceptance. The adhesive attachment shall provide sufficient attachment resistance expressed as a moment to meet or exceed tits required moment of resistance determined in compliance with Miami-Dade County Roofing Application Standards PA 11 S or PA 127. The adhesive attachment data is noted in the roof tilt assembly NOA. Comments: 1. All 'System Limitations' noted in the tile Roof System Assembly Product Control Approval shall apply. Fronk Zuloaga, RRC Roofing Product Control Examiner Apr - 3u -yes U4 ] 1Lr r0 • Uarr1 rr't. CAUCI 1r r4 -_ POLYFOAM PRODUCTS, INC- 7 L." Y I :J 1Y Product Control No.: 98- 0303.02 SYSTEMS (CONTINUED) Deck Type: Concrete, New Construction /Rerouf Deck Description: Ncw construction SYSTEM B: Adhesive Set Application Slope Range: 2 ":12" to 7 ":12" Underlaytncut / Install Approved underlaymcnt system of one of the following: Waterproofing: Underlayment: (30/90 Hot Mop) fully adhered in a full mopping of ASTM U 312 type IV asphalt applied within the EVT range. Back nailing and laps shall be in compliance with Roofing Application Standard PA 120. Any liquid applied roofing system having a current NOA for its use as a tile undcrlayment system. Roofing Tile: Comments: Any roof tile assembly having a current shall be applied in compliance with the Component Application section and the corresponding Placement Details of this Notice of Acceptance. The adhesive attachment shall provide sufficient attachment resistance expressed as a moment to meet or exceed the required moment of resistance determined in compliance with Miami-Dade County Roofing Application Standards PA 115 or PA 127. The adhesive attachment data is noted in the roof tile assembly NOA. 1. All 'System Limitations' noted in the tile Roof System Assembly Product - Control Approval or waterproofing component Roofing Component Product Control Approval shall apply, as applicable. Page 8 of 15 Frank Zuloaga, RRC Roofing Product Control Examiner Table 1: Adhesive Placement For Each Generic Tile Profile Tile Profile Placement Detail 1 -Piece Barrel 01 'S' Shaped #2 Double Roll {t3 Flat #4 r N v - — ate %. -. . ...... r ... •,. vu••• • • • POLYFOAM PRODUCTS, INC. Product Control No.: 98- 0303.02 COMPONENT APPLICATION 1. Polypro® A1-1160 tilt adhesive shall only be applied over an undcrlayment installed in compliance with application instructions detailed in its NOA.. Underlayment may be any undcrlayments or underlayntent systems listed Miami -Dade County Roofing Application Standard I'A 120. 2. Adhesive application shall be in accordance with the instructions provided herein. Tthe manufacturer may provide additional instructions subsequent to this approval date which may prevail. Installation must be by a Factory Trained 'Qualified Applicator' approved and licensed by Polyfoam Products, Inc. 3. Calibration of the Foantpro® dispensing equipment is required before application of any adhesive. The mix ratio between the "A" component and the "B" component shall be maintained between 1.0- 1.15 (A) : 1.0 (R). The dispense timer shall be set to deliver 0.08 to 0.15 pounds per the as determined at calibration. No other settings shall be approved without revision of NOA. 4. Adhesive shall be dispensed in a 17 in to 23 in' pad at time of application. The cured pad shall be approximately 5" x 12 ". Foam placement shall be in accordance with the 'Placement Details' herein. Each generic tile profile requires a specific placement, as noted in Table 1, below 5. Adhere tile directly in freshly applied adhesive. Tile must be set within 2 to 3 minutes after foam has been dispensed. Page 9 of 15 Frank Zuloaga, RRC Roofing Product Control Examiner Apr -30 -98 04 :13P Polyfoam Products Inc. POLYFOAM PRODUCTS, INC. Page 1 0 of 15 Product Control No.: 98- 0303.02 SYSTEM LIMITATIONS 2. Polypro® AH160 adhesive shall be installed only by 'Qualified Applicators' approved and licensed by Polyfoam Products. Inc. 3. For adhesive set the applications. a field static: uplift test by a Miami-Dade County x PA 106, OG, testing agency, in compliance with Miami -Dade County Roofing Application shall be required not less than 72 hours after application to confirm tile adhesion. 4. Refer to application tenninations Pdsbwrell by Details' Mann ludcdcwi for NOq, penetrations and S. Refer to tile Roof Tile Assembly Product Control NOA for system acceptance with. this Component. 6. Refer to the Prepared Roof Tile Assembly for fire rating. 7. Polypro® AH160 shall not be exposed permanently to sunlight. g. Polypro® AH160 shall be applied with Foampro RTF1000 dispensing equipment only. 9. Polyfoam Products Inc. shall supply Building Official with a list of 'Qualified Applicators' approved and licensed by Polyfoam Products. Inc. Frank Zuloaga, RRC Roofing Product Control Examiner Apr - 30 -98 Uzi : 1 y h' ro iy UO'ii rr rw` POLYFOAM PRODUCTS, INC. PLACEMENT DETAILS Placement Detail #1: Two-Piece Barrel Profile Page 11 of 15 Product Control No.: 98- 0703.02 Frank Zuloaga. R;RC Roofing Product Control E.xarnincr Apr -30 -98 04 : 141-' vo ay' t-ei111 - — POLYFOAM PRODUCTS, INC. N•11 1Ib..V' r.rtN �....wt trw.w •••.trod by ..d.l PLACEMENT DETAILS (CONTINUED) u.d.rt•r•••e I'age 12 of 15 •py .r..glr .dt,..l.. t. ..U1w. 11 to 21 aquavit 1••••• lot wrtrt r10. !h. 111.. Placement Detail H2: 'S' Shaped Tile Profile Product Control No.: 98- 0303.02 wool. tl•■• Ootp (do. Frank Zuloaga,`RRC Roofing Product Control Examiner • Nit-- 30 98 04: 15-' ►moo tyroam rr-uu..`. L. . POf.YFOAM PRODUCTS, INC. 006.0.....•/ by win.) u•••.l.r....l r ••• c.....• PLACEMENT DETAILS (CONTINUED) ...1, ..�.� �--.. to .••••■ 11.23 .rr. l..1 1..•.t..4 walk the lu.. e ■.. C••••• emir. �.•y r,••..• Afire .i...u r .p from - ---I -- ..- Placement Detail 1$3: Double Roll Profile Pagc 13 of 15 Product Control No.. 9$- 0303.02 ..s cl....• r. 4. • Frank Zuloaga, RRC Roofing Product Control Examiner Aar -3v -moo v•.: 1. - POLYFOAM PRODUCTS, INC. Olga It.•ma7h p ..a. ■•••• (whew. nogreiMed PLACEMENT DETAILS (CONTINUED) 4, 7 ,... femel. ✓ ..e ...... wnl,, k..a w iAwl.• .p..w.' 4'.1 .q kw.. ■••■••■•••• Placement Detail #4: Flat Profile Page 14 of 15 Product Control No.: 98- 0303.02 111„0. .,....• _._.l . to .ck1.,. 17.31 *Aar . I.+b.• fo a.wt.at wWl. UN Ole. n uloaga, RUC Roofing Product Control Examiner e - - I r • POLYFOAM PRODUCTS, INC. Polyfuum Products, Inc. 2400 Spring- Stucbncr Road Spring, TX 77383 v an, r r V 4.1 u C L. 11 I - 7 •I •/ :J - 1 . •* C.1 L NOTIC 9 . CCEPT N 'E STANDAR t CO OITIONS Renewal of this Acceptance (approval) shall be considered after a renewal application has been filed and the original submitted documentation. including test supporting data. engineering documents, are no older than eight (8) years. 2 Any and all approved products shall be permanently labeled with the manufacturers name, city. state, and the following statement: "Miami -Dade County Product Control Approved ", or as specifically stated in the specific conditions of this Acceptance. 3 Renewals of Acceptance will not be considered if: a) 'there has been a change in the South Florida Building Code affecting the evaluation of this product and the product is not in compliance with the code changes; b) The product is no longer the same product (identical) as the one originally approved; c) 1f the Acceptance holder has not complied with all the requirements of this acceptance, including the correct installation of the product; d) The engineer who originally prepared, signed and scaled the required documentation initially submitted. is no longer practicing the engineering profession. 4 Any revision ur change in the materials, use, and/or manufacture of the product or prncess shall autumatienlly be cause fnr termination of this Acceptance. unless prior written approval has been requested (through thc fihittg of a revision application with appropriate fee) and granted by this office. 5 Any of the following, shall also bc grounds for removal of this Acceptance: a) Unsatisfactory performance adds product or process; b) Misuse of this Acceptance as an endorsement of'any product, for sales, advertising or any other purposes. 6 The Notice of Acceptance number preceded by the words Miami -Dade County. Florida. and followed by the expiration date may be displayed in advertising literature. If any portion of the Notice of Acceptance is displayed. then it shall be done in its entirety. 7 A copy of this Acceptance as well as approved drawings and other documents, where it applies. shall be pruvidcd to thc user by the manufacturer or its distributors and shall be available for inspection at the job site at all times. Thc copies need not bc resealed by the engineer. g Failure to comply with any section of this Acceptance shall be cause for termination and removal of Acceptance, 9 'I his Acceptance contains pages 1 through 15. END OF THIS ACCEPTANCE Page 15 of 15 Product Control No.: 98.0 }03.02 ACCEPTANCE NO: 98- 0303.02 APPROVED : April 16, 1998 EXPIRES : Apri116.2001 Frank.uloaga, RRC Rooting Product Control Examiner - 1 O r t,Ski s 'J1o3 c, HDI. JUrrL u BUILDING CODE CONtPI.IAW nTM`r :"LACIL:;ia t:83,iq[ 0 140 WEST Ft.AGLER STREET. SUITE 1603 MIAMI. FLORIDA 33130.15D3 PRODUCT CONTROL NOTICE OF ACCEPTANCE (3os3 375.3901 FAX (303) 373 -:9011 CONTRACTOR LiCgv$I(C SECTION (305)375 - -'5:7 FAX MS) $ --3S11 CONTRACTOR LNFORCESIILNr SECTION 0051 175-M6 FAX (3651171.Z9/35 PRODUCT CONTROL DIVISION (305) 31S -:90: FAX (305) 37_.6339 Your application for Product Approval of: GA F Conventional Buili -Up Roof Systems for 1Voud Deck. under Chapter 8 of the Code of Miami-Dade County governing the use of Alternate Materials and Types of Construction, and completely described herein, has been recommended for acceptance by the Miami'Dade County Building Code Compliance Office (BCCO) under the conditions specified herein. This approval shall not be valid after the expiration date stated below. BCCO reserves the to secure this product or material at anytime from a jobsite or manufacturer's plant for quality control testing. If this product or material fails to perform in the approved manner, BCCO may revoke. modify, or suspend the use of such product or material immediately. I3CCO reserves the right to revoke this approval, it' it is determine. BCCO that this product or material fails to meet the requirements or the South Florida Buildings Code. G.A.F. Materials Corporation 1361 Alps Road Wayne NJ 07470 The expense of such testing will be incurred by the manufacturer. Acceptance No.:00-0331.I5 Expires:11 /04/2003 TII'1S IS TIIE COVERSIIEET, SEE ADI)iT•IONAL PACES FOR SPECIFIC AND GENERAL • CONDITIONS BUILDING CODE & PRODUCT REVIE\\• CU, »I'IITTEE anpli,:ation for Product Approval has been re%ie ed by the BCCO a,,.! approved by the Bttildingg Code :t:'.k.t Product Rc•: iew Committee to be used in Dade County, Florida under the conditions set forth above. App roved: 06/29/2000 Internet mail address: postmaster bus ld•+ngcodeonline.eom oli rtit rcD 1G ✓)1 1 :G1 • t om.■ • MIAMI -DAD€ COUNTY, METRO -DADE FLAGLER 8 Raul Rodriguez Chief' Product Control Division Hom e: htt : //ww • •runCisco Quintana. R.A. Director I of 32 Miami -Dade County • Building Code Compliance Ott • CA 1 , %iATERIA S CORPORATION s �at • • rv: Sub- Ctjettory: Deck Tyne: N102th Im_csien Pressm (?jr e Ctgssification: ROOFINC SYSTEM APPROVAL Reuling BUR Wood -75 pSf Sir General Limitation 4I TRADE NAMES OF' PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: Product GAF Asphalt Concrete Primer GAF Mineral ShieldD Granules GAF WeatherCoatZ Emulsion GAF Premium Fibered Aluminum Root; Coatin GAF Jetblak All .veatltier Plastic Cement RL'13CR0!Dg ■tvs,lilied C3ttumen Flashing Cement Jetblack Premium Flashing Cement GAFGLAS® #75 GAFGLAS #30 Ultima Base Sheet GAFGLAS Ply 60 Dimensions 5, S5 gallons 60 lb. bads 5 gallons 1, 5 callous 1,5 gallons 5 gallons 5 gallons 3 sq. roll 75 Ib. roll 2 Sq. Roll 70 I bs. /rol l 5 sq. roll 45 Ib. roll Test Specification ASTM D 41 ASTM D 1363 AST ASTM D 3324 ASTM D 4601 ASTM D4601 ASTM D 2173 oF32 Approval Date: v • Zy 2 • expiration Date: Novem Product DesCri ntion Asphalt concrete primer used to promote adhesion of asphalt in built -up rooting. Granules for surfacing of exposed asphalt, cold process ceritent or emulsion. GAF Mineral Shield® Granules shall be used for flashintz applications only. 13 Surface coating for smooth surfaced roofs. Fibered alum inuin W;tttnt . ASTM D 3019 Relined asphalt blended with a mineral ASTM D 3409 stabitizcr and fibers. Permits adhesion to vet and dr. 3 ::rfi.es ASTM D 4586 Fiber ASTM D 4586 Asphalt flashing Cement Asphalt impregnated and coated glass mat base sheet. Asphalt impregnated and coated. fiberglass base sheet Type VI asphalt impregnated glass tclt with.asphalt coating. .-ran Zulosga, RRC Roofing Product Control Examiner C 1 2. GAF MATERIALS CORPORATION GAFGLAS Flex p,yTM 6 GAFGLAS Ply 4® GAFGLAS® Mineral Surfaced Cap Sheet GAFGLAS® STRATAVENT® Perforated GAFGLAS® Flashing GAFGLAS® STRATAVENT Naitable RUBEROID Modified 3 sq. roll Base Sheet 67 lbs. OAFTEMPE 1sothe.rm f. Tapered G.AFTE`RPZ Isotherm R. GAFTEMP Isotherm RA Tapered GAFTEMP isotherm RA GAFTEMP isotherm RN Tapered GAFTEMP Isotherm RN TJVJIJl UJI J rl../�.. JVrrLI 5 sq. roll 45 ib. roll 5 sq. roll 76 Ib. roll 60 Ib. roll various 69 Ib. roll various vartouS various various various various Test ASTM D 2178 ASTM D 2178 ASTM D 3909 ASTM D 4897 D 3672 ASTM D 489 D 3672 ASTM 04601, Type [I, UL Type G2 BUR PA 110 PA 110 PA 110 PA 110 PA 110 PA 110 3 of 32 Acceptance No: 0-0331.1S Product Q4 cripfigt� Type VI asphalt imprenated glass felt with asphalt coating. Type IV asphalt impregnated glass felt with asphalt coating. Asphalt coated, glass fiber mat cap sheet surfaced with mineral granules. Fiber glass base sheet impregnated and coated on both sides with asphalt. Surfaced on the bottom side with mineral granules embedded in asphaltic coating ‘vith factory perforations. Asphalt coated glass fiber mat flashing sheet available in three sizes. Fiber glass base sheet impregnated and coated on both sides with asphalt. Surfaced on the bottom side with mineral granules embedded in asphaltic coating. Premium glass fiber reinforced SBS- modified base sheet Polv isocvaourite Foam insulation. Tapered Polt ■socvanurate foam insulation Polyisocyanurate foam insulation Tapered Polyisocyanurate foam insulation Polyisocyanurate foam insulation Tapered Polyisocyanurate foam insulation Frank Zuioaga, RRC Roofing Product Control Examiner 1-,*JJ r JioJ c'j H. JurrL i CAF' MATERIALS CORPORATION GAFTEMP® Composite t' rnftv ct 7)i --- various o ti rcr.J Test Prepd et. ' C tiOg PA 110 Polyisocyanurate foarp insulation with high density fiberboard or Permalite perlite insulation. Tapered GAFTEMP® various PA 110 Tapered Polyisocyanurate foam insulation Composite with high density fiberboard or Permalite perlite insulation. GAFTEMP® various PA 110 Polyisocyanurate foam insulation with Composite A high density fiberboard or Permalite perlite insulation. Tapered GAFTEMP® various PA 110 Tapered Polyisocyanurate foam insulation ' Composite A with high density fiberboard or Permalite perlite insulation. GAFTEMP® various PA 110 Polyisocyanurate foam insulation with Composite N high density fiberboard or Permalite perlite insulation. Tapered GAFTEMP® various PA 110 Tapered Polyisocyanurate foam insulation Composite N with high density fiberboard or Permalite perlite insulation. GAFTEMP® various PA 110 Fiberboard insulation. Fiberboard GAFTEMPE various PA 110 Perlite insulation board. Permalitefi: GAFTEMP Recover 1 /2" thick PA 110 Perlite recover hoard Board Acceptance No: 00 0331.1 S GAFTENIP® various PA 110 High density wood fiberboard insulation. High Density Fi berboard GAFTITE® #12 Standard Roofing Fastener GAFTITE® #14 Heavy Duty Roofing Fastener GAFTJTE ASAP PA 114 Insulation fastener for steel and plywood decks. PA 1 14 Insulation fastener for steel, wood and concrete decks. PA 114 Pre - assembled GAFTITE Fasteners and metal and pl • 4 of 32 ran uloaga, RRC Roofing Product Control Examiner -s-/5j( y HBC SUi-' 'L r CAF MATERIALS CORPORATION t Teat Product ii .i.+. „- a 4.i. +l ;i :il)t 3:iS.J- ai(]+. .i eacrip2io i Acceptance No: 00.0331.15 GAFTITE® Base PA 1 1 4 Base sheet fastening assembly. Sheet Fastener and Plate Gaivalurne Plates 3" and 3 ''A" PA 114 Round galvalume stress plates. oil h'bb rtb iG ' ✓Jl 14:44 NTB Fasteners PA, 114 Fastener for use in gypsum, tectum and lightweight insulating concrete decks. Polypropylene Plates 3" and 3 '/ PA 1 14 Round polypropylene stress plates. Ruberoid® 20 1.5 sq. roll ASTM D 5147 SBS modified asphalt base sheet and 95 lbs. interply sheet reinforce with a glass fiber mat. Ruberoid® Mop 1 sq. roll ASTM D 5147 Non -woven polyester mat coated with Granule 103 lbs. polymer modified asphalt and surfaced with mineral granules. RUI3EROID MOP I sq. roll ASTM D 5147 Non -woven polyester mat coated with Smooth 87 lbs. polymer modified asphalt and smooth surfaced. RUBEROIDB MOP I sq. roll ASTM D 5147 Non -woven polyster mat coated with PLUS 102 lbs. polymer modified asphalt and surfaced with mineral granules. RUBEROID' MOP 1 sq. roll ASTh1 D 5147 Non - Woven polyester mat coated with fire 170FR 103 lbs. retardant poi. mcr modified asphalt and surfaced with mineral granules. RLBEROIDS MOP 1 sq. roll ASTM D 5147 Non -Woven poly ester mat coated with fire FR - 105 lbs. retardant polymer modified asphalt and surfaced with mineral granules. RUBEROID® 1 sq. rol( ASTM D 5147 Heavy duty, polyester reinforced, asphalt TORCH Smooth 87 lbs. modified bitumen membrane, smooth surface. RUBERO(D® l sq. roll ASTM D 5147 Heavy duty, polyester reinforced, asphalt TORCH Granule 102 lbs. modified bitumen membrane, granule surface. RUBEROID® 'A. sq. roll ASTM D 5147 Heavy duty, polyester reinforced, asphalt TORCH PLUS 93 tbs. modified bitumen tnembran surface 5 of 32 n u loaga, RRC Roofing Product Control Examiner GAF NIATERIALS CORPORATION t• RUBEROID® TORCH FR RUBEROID® 30 RUBERO[D® 30 FR RUBEROID ULTRACLAD® SBS Vent Stacks (metal and plastic) GAF Aluminum Emulsion t.:+YJJ r Jib r'y Htil JurrL RUBEROID 109. Roll ULTRACLAD SBS 101 lbs. GAF Aluminum Roof 5 gallons Paint G:\E Built-Up Roofing Asphalt Y4 sq. roll 90 lbs. 1 sq. roll 92 lbs. I sq. roll 92 lbs. 5 gallons 100 Ib. cartons, bulk RUBEROID MOD 60 Ib. kegs Asphalt RUBEROID MOD 60 Ib. kegs Asphalt L RUBEROID MOD 60 Ib. kegs Asphalt P Test .jdJc0.l:��i aflo, ASTM D 5147 ASTM D 5147 rcD 1C YJ1 1G• Acceptance No: 00-013 I, �' . r 0 11 ri Prn ; oescrintion Heavy duty. polyester reinforced, coated with fire retardant asphalt modified bitumen membrane, granule surface. Non woven fiberglass mat coated with polymer modified asphalt and surfaced with mineral granules. ASTM D 5147 Non woven fiberglass mat coated with fire retardant polymer modified asphalt and . surfaced with mineral granules. Isq. roll ASTM D 5147 Woven fiberglass mat coated with Polymer. 101 lbs. modified asphalt and surfaced with • aluminum, copper or stainless steel foil. PA 100(A) One way valve vent used to relieve built - ASTM D 1929 up pressure within the roof system. GAF ASTM D 635 Vent Stacks are available in metal or plastic. None ASTM D2324, Type I ASTNI D312, Types 1, 11, 111 and IV 6 of 32 Mineral colloidal bituminous emulsion with reflective aluminum flakes ASTV1 D 5 147 Woven fiberglass mat coated %vith Polymer modified asphalt surfaced with aluminum. copper or stainless steel foil. Non- fibered. ikon +inurn pigmented, asphalt roof coating Interply mopping and surfacing asphalt SEBS modified asphalt SEES modified asphalt SEBS modified asphalt n • Zuloaga. RRC Roofing Produce Control Examiner CAF MATERIALS CORPORATION r• TRADE NAMES OF PRODUCTS . UU ; D 77 r'77777.7.7 - \ nchorbond Fastener Test Product D tensions $ncci iication Pyrox various ACFoam 1 various ACFoam I1 various Hy -Therm Nail -line various Hy -Therm SP various Hy -Therm AP various Hy -Therm Stable R various Hv -Therm White various Line Dekfast Fasteners »14 Dekfast He Plate 2 7/8" x 3 1/4" Dekfast Lock Plate 3" x 3 1/4" PA 1 10 Polyisocyanurate foam insulation PA 110 Polyisocyanurate foam insulation PA 110 Polyisocyanurate foam insulation PA 110 Polyisocyanurate foam insulation PA 110 .Polyisocyanurate foam insulation. PA 110 Polyisocyanurate foam insulation PA 110 Polyisocyanurate foam insulation PA 110 Polyisocyanurate foam insulation PA ! 14 Insulation fastenin_ assembly PA 1 1 4 Insulation fastener for steel and concrete decks PA 114 Product Desc jtian Galvalume hex stress plate. PA 114 Polypropylene locking plate. 8 of 32 FL-L. 1L Vl 1G.L Acceptance No: 00 -0331.15 ` ;1 • MitnAlpstugx Apache Products Co. (with current PCA) Atlas Energy Products (with current PCA) Atlas Energy Products (with current PCA).. Celotex Corp. (with current PCA) Celotex Corp. (with current PCA) Celotex Corp. (with current PCA) Celotex Corp. (with current PCA) Celotex Corp. (ith current PCA) Celotex Corp. (with current PCA) Construction Fasteners Inc. (with current PCA) Construction Fasteners Inc. (with current PCA) Construction Fasteners Inc. (with current PCA) gaga. RRC Roofing Product Control Examiner +wJJ rJlbJr'7 rick. ourrL GAF MATERIALS CORPORATION 0 GAFTEMP Composite A GAFTEMP Composite N GAFTEMP GAFCANTrM GAFTEMP GAFEOGET.`' Taper-2d Edge Strip GAF rE\1P PER'IAL1TEE Tapered Roof Insulation P ,a Various GAFTEMP Tapered Various Composite A Various GAFTEMP Tapered Various Composite N GAFTEMP Tapered Various Isotherm R GAFTEMP Tapered Various Isotherm RA GAFTEMP Tapered Various Isotherm RN Various Various Various GAFTEMP Recover 1/2" thick, Board Various sizes Shingle- Mater" 4 sq. roll Underlayment 30 lbs. Teat PA 110 7 of 32 o.J. rc,o Polyisocyanurate/wood fiberboard composite PA 110 Tapered Polyisocyanurate/wood fiberboard composite PA 110 Polyisocyanurate/wood fiberboard composite PA 110 Tapered Polyisocyanurate /wood fiberboard composite PA 110 Tapered polyisocyanurate foam PA 110 Tapered polyisocyanurate foam Tapered polyisocyanurate foam Cut perlite board Tapered perlite board PA 110 Tapered periite board PA 110 Perlite board Product Fiberglass reinforced shingle underlayment GAFTITE® ASAP 500 per box PA 114 Pre - assembled fastener and metal and plastic plates rc co c• c� Acceptance No: 00-0331.15 ran Zuloaga, RRC Roofing Product Control Examiner �jvlj r51tiJ r'7 Hbl, SUrrL r CAF MATERIALS CORPORATION A Dekfast Fasteners #14 Dekfast Fasteners #12 [SO 95+ Composite Asphalt Asphalt Primer Perli•_ Insulation Poly :dtvIene Red Ro. >in Roofing Nails Tin Caps MB aluminum roof coating Dens - Deck EPS various High Density Wood various Fiberboard Petite :Urethane various Com`.)s:te various 4 mil min. various Minimum 4 12 Min. 32 ga. x 1 various Test PA 114 Product �w� w ig;eea:t Insulation fasteners for concrete decks PA 114 Insulation fastener for steel and wood decks. PA 110 Pofyisocyanurate / perlite ridged insulation ASTM D 312 Type 111 or IV Hot asphlat bitumin adhesive ASTM D 41 Asphalt Primer PA 110 Extruded polystyrene insulation PA 110 Wood fiber insulation board PA 110 Perlite / urethane composite board insulation PA 110 Perlite insulation board Vapor barrier / Air bar: Rosin paper for barn :r !.11/4 . on wood decks PA 114 Corrosion resistant annular ring shank nails Corrosion resistant circular discs. PA 121 Aluminum roof coating PA 110 Gypsum insulation board. 9 of 32 011 r1YJ r00 14 C)1 1G 4.4 — Acceptance No: 00 -0331. iJ 1'vYAtitt([1�EurCr Construction Fasteners Inc. (with current PCA) Construction Fasteners Inc. (with current PCA) Firestone (with current PCA) generic generic generic generic generic generic generic generic generic generic Grundy Industries (with current PCA) Georgia Pacific (with cu A Frank Zuloaga, RRC Roofing Product Control Examiner & AF MATERIALS CORPORATION #12 Roofgrip H14 Roofgrip Gripdek Fastener Hexcel Fastener Hextra Standard Plastic Plate ISO 95+ E'N RG'Y -2 ISORoc Olympic Fastener #14 Olympic Polypropylene - r JeJJ Jl�J . i nun, .JV{ 1 - ` 3" round various various various Olympic Standard 3" round Test Product ,i)eset Lion PA 114 insulation fastener for steel or wood decks PA 114 Insulation fastener steel, wood or concrete decks PA 114 - Insulation fastener PA 114 Insulation fastener PA 114 Insulation fastener and metal or plastic plate PA 114 Polyolefin plastic plate PA 110 Polyisocyanurate foam insulation PA 110 Polyisocyanurate foam insulation PA 110 Polyisocyanurate foam / rockwool composite insulation PA 114 3" round galvalurnc .AZ» steel plate PA 114 Insulation fastener 3.25" round PA 114 Polypropylene plastic plate 10of32 Acceptance No: 00-0331.13 Yntt � . ITW Buildex • (with current PCA ITW Buildex (with current PCA) 1TW Buildex (with current PCA) ITW Buildex (with current PCA) 1TW Buildex (with current PCA) ITW Buildex (with current PCA) Firestone (with current PCA) NRG Barriers, inc. (with current PCA) NRG Barriers, Inc. (with current PCA) Olympic Nlanufacturine Group, Inc. (with current PCA) . Olympic Manufacturing Group, Inc, (with current PCA) Olympic Manufacturing Group, Inc. (with current PCA) Frank Zuloaga, RRC Roofing Product Control Examiner 1- -)k73 i `r163 i 7 nDl.. Jurr c.A MATERIALS CORPORATION Acceptance No: 000731.I5 r ' rod gct Olympic Fastener #12 Olympic Fastener ASAP Olympic CR Base Felt Fastener and Base Sheet Disc GlasFast Fastener Paroc Base Board Paroc Cap Board Multi -Max Multi-Max FA L.ltraGard Insul -Fixx Fastener Insul -Fixx P Rawl Fasteners #I2 Teat 1Qinenxipn citics0 3g various various various various various 3" round Product PA 114 Insulation fastener PA 114 Pre- assembled Insulation fastener and plate PA 114 PA 114 Insulation fastener assembly with recessed plastic plate PA 110 Rockwool insulation PA 110 Rockwool insulation PA 110 Polyisocyanurate foam insulation PA 110 Polyisocyanuratc `Jam insulation PA 110 Polyisocyanurate Coati, insulation PA 114 Insulation fastener for steel and wood decks PA 114 Insulation fastener assembly for Base Sheet fastening only 3" round polyethylene stress plate PA 1!4 Insulation fastener for steel and wood decks II of 32 Ull ( LL 1 L-IJ 1G V1 1- • : - � - + Olympic Manufacturing Group, Inc. (with current PCA) Olympic Manufacturing Group, Inc. (with current PCA) Olympic Manufacturing'. Group, Inc. (with current PCA) Owens - Corning Fiberglas Corp. (with current PCA) Partek, Inc_ (with current PCA) Partek, Inc. (with current PCA) Rmax, Inc. (with current PCA) Rmax, Inc. (with current PCA) Schuller International Inc. (with current PCA) SFS /Stadler (with current PCA) SFS /Stadler (with current PCA) The Rawlplug Company Inc. (with current PCA) Frank Zuloaga. RAC Rooting Product Control Examiner 1- GAF MATERIALS CORPORAT1ON Prodgct Rawl Fasteners #14 Rawl 2" Plate Rawl 3" Plate Rawlite 3" Plate Super Prep II Tru -Fast DL Tru -Fast HD Tru -Fast Ultra Tru -Fast DP Tru -Fast TP Structodeck TJc1J .JlJ.J i 7 r1L01., JLJrr L I 2" round 3" round 3" round various Teat PA 114 PA 114 2" round galvalume AZ55 membrane plate PA 114 3" round galvalume AZ55 steel plate PA 114 PA 121 Roof coating PA 114 insulation fastener for steel, or wood Tru -Fast Plastic 3.04" round PA 1 1 4 3.04" round polyethylene Plate plastic plate Tru -Fast MP -3 3.23" round PA 11-1 3.23" round galvalume AZ50 steel plate PA 114 PA 1 14 PA 114 Insulation fastener for use in steel or wood decks PA 114 Insulation fastener for use in steel or wood decks PA 110 High density wood fiber 12 of 32 Product Insulation fastener for use in The Rawlplug steel, wood or concrete • Company Inc. (with current PCA) The Rawlplu Company Inc. (with current PCA) The Rawlplug Company Inc. (with current PCA) The Rawlplug Company Inc. with current PCA) 3" round galvalume AZ55 steel plate for use with Rawlite fasteners Insulation fastener (or nse in wood, steel or conerece decks Stainless Steel fastener for use in steel, wood and concrete decks Acceptance No: 00- 0331.13 T ( tv aau6ke: + hermo- Materials, Inc. with current PCA) Tru -Fast (with current PCA) Tru -Fast (with current PCA) Tru -Fast (with current PCA) Tru -Fast (with current PCA) Tru -Fast (with current PCA) Tru -Fast (with current PCA) Tru -Fast (with current PCA) Frank Zutoaga, RRC Roofing Product Control Examiner *3lJJ i JloS r'7 I-IL but i • t: AF "MATERIALS CORPORATION Test Agency Factory Mutual Research Corporation Factory Mutual Research Corporation Factory Mutual Research Corporation Factory Mutual Research Corporation Factory Mutual Research Corporation Factory Mutual Research Corporation Underwriters Laboratories, Inc. Dynatech Engineering Corporation D.natech Engineering Corporatio:: Test identifier FMRC 1996 1.1. I V8A4.AM 1.I. 2B8A4.AM 1.1.3B9Q1.AM 1.I. ODOA8.AM 1.1. OD I A8.AM J.I. 0Y9Q5.AM 1.1. 3X3A2.AM J.I.0Y9Q5.A,Lt R1306, 87NKI (8(9 143600.02.95- 1 844 82.02.95- I 13 of 3? Dcscr(ption ,• Current Insulation Attachment Requ irements Wind Uplift FMRC 4470 - PA 114 Wind Uplift FMRC 44704 Wind Uplift PA 114 Wind Uplift PA 1;4 0 1 rl-• Wind Uplift FMRC 4470 - PA 114 Wind Uplift FMRC 4470 - PA 1 14 Wind Uplift FMRC 4470 - PA 114 V L.L) 14. Li, a • --1 Acceptance No: 00-0331.15 Pate 01.01.96 06.28.93 07.02.97 01.08.98 07.09.99 07.29.94 04.01.98 08.02.94 07.29.94 Fire Resistance Classification 01.01.93 UL790 - PA 114 02.02.95 02.02.95 Frank Zuloaga, RRC Roofing Product Control Examiner TJfJ.� J1 VJ 1 7 ,-, ,LS - I L L1 GAS' MATERIALS CORPORATION Systems Deck Type 11: Wood, Insulated, New Construction or Reroof Deck Description: 19/ or greater plywood or wood plank System Type A(I): Anchor sheet mechanically fastened, all layers of insulation adhered with approved asphalt. All General and System Limitations shall apply, Insulation Fastener Fastening Layer Type t Fasteners Fastener Detail No. Per Board Density One or more layers of any of the following insulations. Approved Type(s): ACFoam -I, E'NRG'Y 2, GAFTEMP® Isotherm R, E'NRG'Y 2 Plus, GAFTEMP Isotherm RA, GAFTEMP Isotherm RIY, GAFTEMP Composite, GAFTEMP Composite A, GAFTEMP Composite N Minimum: I" x 3' x 4' N/A N/A N/A N/A Approved Type(s): TSORoc, GAFTEMP® Tapered Minimum: I" x 4' x 4' N/A N/A N/A N/A Approved Type(s): High Density Wood Fiber, GAFTEMP® High Density Wood Fiber, GAFTEMP RecoverBoard Minimum: 72" x 4' x 4' N/A N/A N/A N/A Approved Type(s): Wood Fiber, GAFTEMP® Fiberboard Minimum: %2" x 2' x 4' N/A N/A N/A N/A Approved Type(s): Paroc Minimum: 3 /." x 4' x 4' N/A : \ppro'cd Type(s): Pertite, GAFTE,MIP® Permalitc®, Permalitc T pered Minimum: ?'Y x 2' x:1' N/A N/A N/A Minimum N/A (for Tapered)' /." x 2' x4' N/A Approved Type(s): Fiberglas Minimum: t5 /16" x 4' x 4' N/A Approved Type(s): Permalite Tapercd Roof Insulation Minimum: V. " x 2' x 4' N/A N/A 14 of 32 N/A N/A N/A N/A N/A N/A Acceptance No: 00-0331.15 • • N/A N/A N/A N/A Approved Type(s): Tapered isotherm R, Tapered Isotherm RA, Tapered IsothcrmRN, GAFTEMP Composite Tapered, GAFTEMP Composite A Tapered, GAFTEMP Composite N Tapered Minimum: '''h" x 4' x 4' N/A N/A N/A N/A Frank Zuloaga, RRC Roofing Product Control Examiner T.JtJJ J1vJ i 7 rtrA. JUf rL i GAF MATERIALS CORPORATION -45 psf (See General Limitation 47) Maximum Fire Classification: See General Limitation #1. Maximum Slope: See General Limitation #1. Oil rJO rcD lc CJl Acceptance No: 00-033L I S Note: All insulation shall be adhered to the .ont ?”,r 1'01. v ' an:v ae a rote a,' - 40 ibsJn ?lease refer to Metro -Dade County Roofing Application Standard RAS 117 for insulation attachment. Insulations listed as base layer only shall be used only as base layers with a second layer of approved top layer insulation Installed as the final membrane substrate. Composite insulation panels may be used as a to layer placed with the polyisocyanurate side facing down. GAF requires either a ply of GAFGLAS STRATAVENT® perforated laid dry or a layer of GAFTEMP® PERMALITE or wood fiber overlay board on all isocyanuratc applications. Anchor sheet: GAFGLAS Ply 4 ®, Ply 68, GAFGLAS Flex Ply" 6, 1175 Base Sheet, GAFGLAS #80 UltimaT" Base Sheet, STRATAVENT® Nailable, RUBEROID Modified Base Sheet or RUBERO[D® 20 base sheet applied to the deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" o.c. at the lap staggered in two rows 12" in the field. Base sheet shall serve as anchor sheet for attachment of insulation Base Sheet: (Optional) Install one ply of GAFGLAS® #75, GAFGLAS #80 Ultima"' Ultra Base Sheet, GAFGLAS STRATAVENT® Perforated or RUBEROID Modified Base Sheet directly over the top layer of insulation. Adhere with any approved mopping asphalt applied within the EVT range and at a rate of 20 -40 lbs. /sq; (see General Limitation #4). Ply Sheet: One, two, or three plies GAFGLAS PLY 40, GAFGLAS® PLY 60 Ply or GAFGLAS Flex Ply 6 sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20 -40 lbs. /sq.. Cap Sheet: (Optional) One ply of GAFGLAS® Mineral Surfaced Cap Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20 -40 Ibs.sq.. Surfacing: (Required if no cap sheet is used) Install one of the following: 1. GAF Special Roofing Bitumen with an application rate of 20 lbs. /sq with an application rate of 1.5 gal. /sq.: or GAF WEATHER COATE Emulsion with an application rate of 3 gal. /sq.; or GAF Premium Fibercd Aluminum RuoCCoating with an application rate of 1.5 gal. /sq.. 2. Asphalt flood coat at an application rate of 60 lbs. /sq. t 20 %; plus gravel or slag with an application rate of 400 lbs. /sq. & 300 lbs. /sq., respectively. Maximum Design Pressure: Specification No.: 1-B-5-M, 1- B- S -M/P6, T- B-5 -G, I- B- 5 -G/P6, t- 8 -5 -C, l- B- 5 -C /P6, 1- 0 -5 -M. 1- 0- 5 -M/P6 1- B -a -M, 1- B- 4 -M /P6, t- 0-4 -M, 1- 0- 4 -M /P6, 1- B -4 -G, 1- B- 4 -G/P6, I- 0 -4 -G I- 0- 4- G -/P6, 1- 0-4-C, 1- 0- 4 -C /P6, t- B -4 -C, 1- B- 4 -C/P6, 1- B -3 -M, 1- B -3 -G, 1- B -3 -C, 1- 0 -3 -M, T- 0 -3 -G, 1 -0 -3 -C 15 of32 Roofing Product Control Examiner GU. rJ63 1 Jic.J i Jur .ANA 1 tt <IAL, CORPORATION 1 • Wood Deck System Lin itwions: A slip sheet is required with Ply 48 Flex Ply"' 6 and Ply 6® when used as a mechanicntly fastened be or anchor sheet. '" 2. Y_ Type X gypsum board is acceptable to be installed directly over the wood dcc -_ 30 or ';2 Acceptance Nu: 00- 0331,13 Frank Zuioaga. RRC Rooting !'rocuct Control Examiner 31 of 32 311 • J. •—• �Ur 'CAF NIATERIALS CORPORATION Acceptance No: ¢11- 0331.13 r„ £v .�, ,tgi f ire classification is not part of this a„_� refer to a current Approved Rooting Materials Directory for fire ratings of this product. Insulation may be applied in multiple layers. r, . ,..,,,p,z �,.��,,. The first layer shall be attached in compliance \vith Product Control Approval d i iw,s ii .rr��•••� guidelines. All other layers steall be adhered in a full mopping of approved asphalt applied within the EVT ranee and at a rate of 20 -40 lbs. /sq., or mechanically e a tt a chd sn . he fastening •..,w using t o�b n tc ta,tC,ilnb patiern of the top iayer. 3 Al! standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size shall be a' x 4' maximum. •. 4 An overlay and /or recovery board insulation panel is required on all applications over closed cell Foam insulations when the base sheet is fully mopped. It' no recovery board is used the base sheet may be applied using spot mopping with approved asphalt. 12" diameter circles, 24" o.c.: or strip mopped 8" ribbons in three rows, one at each sidelap and one do\c'n the center or the sheet allowing a continuous area of ventilation. Encircling of the strips is no acceptable A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application of eithety system shall be at a minimum rate of 1 lbs. /sq, Nnte Spot attached systems shall be limited to a maximum design pressure of - rt 5 Fastener spacing for insulation attachment is based on a Minimum Characteristic Forte (F value of 275 !bf„ as tested in compliance with TAS 105. If the fastener value. as Field - tested, is below 375 Ibf., insulation attachme shall not be a.,. .a,.,.cNia 6 Fastener spacing for thlecllanieal attachment of anchor /base Sheet or membrane attachment is based o!h n in inhurn fastener resistance value in conjunction with the maximum design value listed w ;ri "^ the specific system. Should the fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing. prepared. sinned and staled by a Florida Registered Engineer or Architect may be submitted. Said revised fastener spacing utilize the :vithdrawai resistance value taken from Miami - Dade Protocol TAS 105 and calculations in compliance with Miami - Dade Rooting Application Standard Rr \S 1 1 7. Perimeter and corner areas shall comply with the enhanced uplift pressure of these areas. as cal,ulated in compliance :yid] Chapter 23 of the South Florida Buildinv. Code. Fastener densities shall be increase for both insulation and base sheet as needed calcu':aeJ in cotnpliat,se \c late \l . 1 1 1 1 1 D.1iie Roofing Application Standard TAS I 1 7. (When tlti s _•iiir• t t•cferret1 \Nitliin this NO►A, General Limitation #9 will not he Applic; hl \i! attachment and Sizing of perimeter [Milers, metal p an d! 11, ;"„ ^ ,•i11i;, atioil desie s shall conform with N'tiaini -Dade County Root ng A :on Standard TAS and the \ \ind 10. requirements of Chapter 23 of the South Florida Building Code. 9 The maximum designed pressufe limitation listed shall be applicable. to all root pressure Zones (i.C. field, perimeters c o rn e r s No rational analysis. nor extrapolation shall oc permitted for enhanced fastening at enhanced pressure zones (Le. perimeters, extended corners, and corners). (When this I' '►..• :..n is specifically referred ivitiiirl this ■NOA, General Limitation will not be applicable.) fG�� ~ice Frank Zuloaga, RItC Rooting Product Control Examiner 7.1 o3 I . GAF MATERIALS CORPORATION • NOf'Jc'F: OF A. r:7 I Renewal of this Acceptance (approval) shall be considered after a renewal application has been filed and the original submitted documentation, including test supporting data engineering documents, are no older than eight (8) years. Any and all approved products shall be permanently labeled with the manufacturer's name, city, state, and the following statement: "Miami -Dade County Product Control Approved ", or as specifically stated in the specific conditions of this Acceptance. 3 Renewals of Acceptance will not be considered if: a) There has been a change in the South Florida Building Code affecting the evaluation of this product and the product is not in compliance with the code changes; b) The product is no longer the same product (identical) as the one originally approved; c) If the Acceptance holder has not complied with all the requirements of this acceptance, including the correct installation of the product; d) The engineer who originally prepared, signed and sealed the required documentation initially submitted, is no longer practicing the engineering profession. 4 Any revision or change in the materials, use, and/or manufacture of the product or process shall automatically be cause for termination of this Acceptance, unless prior written approval has been requested (through the filing of a revision application with appropriate fee) and granted by this office. 5 Any of the following shall also be grounds for removal of this Acceptance: a) Unsatisfactory performance of this product or process; b) Misuse of this Acceptance as an endorsement of any product, for sales, advertising or any other purposes. 6 The Notice of Acceptance number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. if any portion of the Notice of Acceptance is displayed, then it shall be done in its entiret>. A copy of this Acceptance as well as approved drawings and other documents, where it applies, shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at all times. The copies need not be resealed by the engineer. 8 Failure to comply with any section of this Acceptance shall be cause for termination and removal or Acceptance, 9 This Acceptance contains pages 1 through 32. END OF THIS ACCEPTANCE 32 of 32 L1.1. 1 17 Acceptance No: 00 -0331. I g,... Frank Zuloaga, RRC Roopng Product Control Examiner a 51" ring costs 'series' d illQ", at 1.1 a 1 -1, 2 s, app era' L, pp 7 'Aar -1 2g . ..'plc r A00" i; sq. f 3 i /51tiJ r 7 H6(... , .1•■••••• ..� • GICJ ROOF COMM IIIATEPEALA Roofing Sy, to (TGFu)--Caelthstatd ! ; e'er „ C Uri a0 , applied at 1-1/4 gal / sq (12 dry )2&4 el t or Inc11i 1/4 , sk g L or "Poly-iso Special" with " Polyfoam 251" or "Poly - losrns 1 u+ mut one or two applications "Gacoflex U13-64 ", 1 gal /sq/ saw Coat (12 -24 dry �} s • "Gacoflex UA -65" Series 1 gal /sq or "Gacoflex UA -60", applied at 1.1/ gal /sq (12 dry mils). Incline: l/a ANC "poiy.ise" or " Poly -Iso Special" with "Polyfoam 251" or "Poly - Foaac fee, 303". in. mint 120 coat One or two applications " Cacoflex UB- 7050", applied al I sq application or three applications, • applied 1.1 /4 gal/sq/ application (16.32 dry mils). facing "Gacoflex UAOS" Series (various colors), applied 1 gal/ sq (12 dry mils). akin NC Incline: 1/2 foam "Poly -(so" or "Poly -Iso Special" with "Polyfoam 251" or "Poly- foam 303 ", 1 in. min Base Coat: One or two applications "Gacoflex UB- 7050", applied at 1 ga l sq; application or three applications, applied 1 -114 gal /sq/ a pplication (16-32 dry mils). Surfacing: "Gacoflex UA -60" Series (various colors), applied 1 gal /sq .13 .in costal. Incline: 2 Deck: C F oam: ••'kk.dso" or "Poly -Iso Special" with "Polyfoam 351" or "Poly- roam 303 "'. 1 in. min. Rase Coat "CacoSil 5- I000 ", applied at 1 gal/ sq (10 dry mils). Surfacing "Gacoflex S- I000 ", applied at 1 gal /sq (10 dry mils). 1r Deck: NC Incline: 1 Foam: "Polyfoam 251" or "Polyfoam 303 ", any thickness. Surfacing "Cacoflex Lure- Shield 7007", 4o dry mils. 111 Deck: NC Incline: 2 Foam: "Polyfoam 275 ", any thickness. Base Coat "Gacoflex A- 6111 ". 1 -1 gal /sq (14 dry mils). Surfacing: "Gacoflex A- 6200" series (various colors), 1.1/2 .n• mils). :a Deck: NC Incline. _ Foam: Poll loam 251. "Polyfoam 275" or "Polyfoam 303 ". any thicknes ?. 8ase. Coat: .one or two applications "Gacoflex LB- 70aA ". applied at 1 :ai ( ' F7 :canon (16 -32 dry mils). Surfacing: Ore application of "Gacoflex A -53 Series" (various colorsi, i C -, r•_ 1 -: _ gal sq. (l3 dry mils)- = Deck: \t: Incline: 1; 1 Foam: Polyfoam 251. "Polyfoam 275' or " Polyfoam 303 ". any thicl.- Base Coat: "Cacnflex L8 -6-1," applied at 1•1 i 2 gal: sq. (18 dry mils). Trowel Coat: 30/60 mesh crushed walnut shells mixed at a rate of t. gal with "Gacoflex LB -64," applied at 1.1/2 gal/ sq or "Gacoflex 113.64", applied at 1.1/2 gal/ sq (18 dry mils) followed by the broadcast application of 30/60 mesh crushed walnut shells applied at 7 -8 lb /sq. Su:facie% "Gacoflex U-66 ", applied at 1/2 gal /sq. (6 dry mils). MATERIALS CORP R1306 ALPS RD, WAYNE Nj (17470 20" or "RUBT>ROI D Modified Base Sheet" may be utilized as an G2 base sheets in any of the following Classifications (tmh%) gypsum board or 1/4 m. dtidt (rata►) Georgia -Pad&c rwerisymett bond stay be used In ncesuanbus- .Csaufiestics. t i. - this is doers, the is tour use over • • q• • , (15/32 in. tads° roof bn Boat! and . boeid are offset 6 fit with fie the ie pert the soot greens, R must be below the board. multiple plies of "GAPGtAS Ply 4" or "Ply 6" may be adhered to ' in hot asphalt. bst Stratavent Nailable Base Sheet" may be mechanically attached P over noncombustible decks and as a recover over existing roof 1.AS Perlite Insulation may be utilized as a cover board over "EVER - a �v insulation in any of the following systems. ASPHALT FELT SYSTEMS WITH NOT ROOFING ASPHALT �as alt glass mat base sheet ("CAFGI.AS 475 Base Sheer or Premimum Base Sheet" ) is a suitable alternate for Type GI mss fiber ply sheet ( "GAFGLAS Pty 4" or "GAFGI.AS Ply 6" ) to the gal /sq (14 LOOK FOR THE UL LARK ON PRODUCT rCD 1G t:11 y 1G; 1" Reofing'Systenta cr The mcd deck raay 1> a es7errod with a `typo G2 sheet "GAPGLAS Strelrvant (Vent -Ply) Perforated ea (Vent -Ply) for ngfleble deers" Perforated to be mopped attached granule zdda down. • Aa an G Type Ca asphalt glass sat base sheet r Sheer, " GAFGLAS di80 Preens= Base Sheets or "G (Vent -Ply) for nai)able decks ".) m�ay be substituted for GI ply sheet ("GAFGLAS Ply 4" or "CAFGLAS Ply 6 ") as the the following systems. Bottom ply or base sleet may be solid mopped spot mopped err fastened. u nless otherwise indicated, all insulations may be hot mopped or �t• rally fastened. "GAFGLAS Flashing" or "Ruberoid" may be used for flashing in any et th. Class A, B or C systems listed below. When " perlite" is referenced. this includes "GAFTEMP PERMALrTEV any other UL Classified perlite insulation. ed stone or slag are suitable alternates for gravel in arty of the am A B or C systems listed. Structural cement fiber building units are considered suitable to be included as a deck in the following Class A, B or C systems listed over C -15/32 or NC. The use of gypsum board under any of the following Class A. B or C systems does not adversely effect the rating. The use of 1/2 in. min gypsum board is an acceptable alternate for insulation over C -15/ 32 decks. The use of polystyrene insulation board between min 3/4 ir. ppeerlite board and deck wtth rosin paper (perlite /rosin paper /polystyrenefperlite) is a suitable alternate for isocyanurate board in the following Class A. B or C systems. "GAFTEMP Isotherm RA ", "GAFTEMP Tapered Isotherm RA" and "CAFTEMP Composite A" may be substituted for any isocyanurate insulation in any of the following Gassifications. Trumbull "Perma Mop" may be utilized with any of the following "Asphalt Felt Systems with Hot Roofing Asphalt". GAFGLAS 480 Premium Base Sheet may be used in any of the following systems. "CAFgg)as Flex Ply 6" is a suitable alternate to "GAF las Ply 6 ". "GAFTEMP Permalite Recover Board" may be used in lieu of any perlite insulation in any of the following NC Classincations . Class A. B and C Hot roofing asphalt, for use with organic and glass felts of modified bitumen membranes. "Rubero)d Heat Weld" SRS roofing membraner may be used in lieu of "Ruberutd Mop" SBS products in any applicable Classincatwn. Class A 1. Deck: C -15: 32 Incline: 3 Insulation (Optional): Onc or mote layers perlite, wood Aber, glass fiber isocyanurate, urethane. perlite. isoc afurate composite. perlite urethane composite. a':wd fiber: )e.tcvanurate compnssre. phenolic, art' thickness. Ply Sheet: Three or more later+ Type Cl "GAFCL.AS Ply 4 - or "CAFGLAS Ply 6 ". hot mopped. Surfacing: Gravel. 2. Deck: C -13/32 Incline: 2 Insulation (Optional): One or more layers perlite, wood fiber, glass fiber: isocyanurate, urethane, perlite/isocyanurate composite, perllte/ urethane composite, wood fiber /istxyarturate composite, phenolic any thickness. Ply Sheet Three or more layers Type GI "CAFCLAS Ply 4 or "GAFGLAS Pl 6 ". Cap Sheet One layer Type G3 "GAFGLAS Mineral Surfrad Cap 3. Dada NC • i • Indian - oe (O math One as more layers , isotpstt b perfite/ieoeyenurate =dime oompante, wood der / isocyanurate comp:id max. Ply sheet Two or more layers lrpe GI "CAPCLAS Ply 4" or 'GAF GLAS Ply 6 ". Cap Sheet One layer Type G3 "CAFCLAS Mineral Surfaced Cai Sheet". 4. Deck NC Incline: 111 Insulation: One or two layers "Isotherm R". 4 in. max. hot mopped. Ply Sheet Any el-Classified gravel surfaced Class A asphalt glass 6be mat system. 3. Deck: C -15132 Incline: 1 Slip Sheet (Optional): Red rosin paper, nailed to deck- BUILDING ELECTRICAL PLUMBING ROOFING Owner of Building Architect Contractor or Builder Legal Description Address of n - MIAMI SHORES VILLAGE, FLORIDA PERMIT IT? 11663 ❑ Work to be performed under this Permit • 3yi ! d i Yr t • /.444- 1 • Lot �''• Building 1 This permit is granted to the contractor or builder named above to construct the building or to install the equipment or device described in the application herefor in strict compliance with all ordinances pertaining thereto and with the understanding that the work will be performed in compliance with any plans, drawings, statements or specifications that may have been submitted to and approved by the proper municipal authorities. This Permit may be revoked at any time if the work is not done in compliance with such ordinances or if the plans are changed without authorization. A further condition upon which this permit is granted is the understanding that the contractor or builder named above assumes the responsibility for a thorough knowledge of the ordinances and regulations pertaining to the work covered hereby whether shown on the plans or drawings or in the statemepts or specifications and that he assu s responsibility for work done by his agents, servants or employees. CONTRACTOR OR _ UILDER Bl. Signed• • / Subdi- vision Value of Project $ DATE‘" / ' ` � 195 Contractor's License No 9• Amt. of Permit BY INSPECTOR • $ In consideration of the issuance to me of this permit I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting tytis perm ! I$s aume responsibility for all work done by either, myself, my agent, servant or employee. 4 ' . 4 — SC.' AUTHORITY MIAMI SHORES VILLAGE APPLICATION FOR BUILDING PERMIT Application is hereby made for the approval of the detailed statement of the plans and specifications herewith submitted for the build- ing or other structure herein described. This application is made in compliance and conformity with the Building Ordinance of Miami Shores Village, Florida, and all provisions of the Laws of the State of Florida, all ordinances of Miami Shores Village and all rules and regulations of the Building Division of Miami Shores Village shall be complied with, whether herein specified or not. A copy of approved plans and specifications must be kept at building during progress of the work. Owner's Name and Address r _ _ ___: - ' - Cw t BUILDING INSPECTION DEPARTMENT r Street and Number where work is to be done > State work to be done and purpose of building (by floors) Date 6 /if No.__ i- Street Registered Architect and /or Engineer z Name and address of licensed contractor ,"�� ` -^-'--- Location Location and legal description of lot to be built o �' Lot / i r ° c ' Block 1 1 Subdivision__,-. ® and for no other purpose. New Building Remodeling Addition Repairs No. of St ries__ To be constructed of Kind of foundation Roof Covering Estimated Total cost of improvements $ Amount of .Permit $ Zone cubage required _Plan Cubage Distance to next nearest building Size of Building Lot Maximum live load to be borne by each floor I hereby submit all the plans and specifications for said building. All notices with reference to the building and its construction may be sent to The undersigned applicant for this building permit does hereby certify that he understands and accepts his obligations as an employer of labor under the Florida Workmen's Compensation Act, being Section 5966, Compiled General Laws of Florida, Permanent Supplement, and has complied with the provisions thereof, and will require similar compliance from all contractors or sub - contractors employed by him in the work to be performed under this permit; and will post or cause to be posted for inspection on the site of the work such public notice or notices as are required by the Act. The undersigned agrees to employ only such son work to be performed under this (Signed) � permit, as are licensed by Miami Shores Village. subcontractors, Remarks g , V L'/ Y ^;fi0-°i J i __ STATE OF FLORIDA, COUNTY OF DADE. ss. Before me, the undersigned authority, a notary public, duly authorized to administer oaths and take acknowledgments, personally ap- peared to me well known, and who, being by me first duly sworn, upon oath deposes and says that he is the of the above described construction, that he has carefully read the foregoing application, and that he did sign the same, and that all facts therein by him stated are true. Permit No Date Read, Sworn to and Subscribed before me. Disapproved Date ( Signed) Notary Public, State of Florida E Bg Building Inspector My Commission Expires PLANNING BOARD DATE Chairman Member Member Member Member Member Council Approved Date Disapproved Date NOTE: A charge of $1.00 will be made for making corrections or changes to this application after approval has been obtained from the Planning Board. A re- inspection fee of $1.00 will be charged when such re- inspection is made necessary by improper notice for inspection or faulty materials and /or workmanship.