RHVAC - Residential & Light Commercial HVAC Loads Program
Gemaire Distributors, Inc.
Miami, FL 33122
Project Summary
Client:
Address:
City:
Phone:
Fax:
Design Data
Project Name:
Reference City:
Daily Temperature Range:
Latitude:
Elevation:
Winter:
Summer:
Check Figures
Total Building Supply CFM: 1320 CFM per square foot: 0.825
Square feet of room area: 1,600 Square feet per ton: 506.527
Building Loads
ALICE WILLIAMS
54 NORTHEAST 100 ST.
MIAMI SHORES, FL.
k
02-23 -2001
Company:
Representative:
Address:
City:
Phone:
Fax:
Comment:
NEW SPLIT SYSTEM AIR CONDITIONER
Miami, Florida
Low
45 Degrees
7 Feet
Outdoor Outdoor Indoor Indoor Grains
Dry Bulb Wet Bulb Re1.Hum. Dry Bulb Difference
40 N/A N/A 72 N/A
90 78 50% 75 61
Elite Software Development, Inc.
NEW SPLIT SYSTEM AIR CONDITIONER
ALL AMERICA
JOHNNY PEREZ
7901 WEST 25 AVE. # 3
HIALEAH, FL. 33016
305- 888 -9641
Total heating required with outside air: 54,046 Btuh / MBH
Total sensible gain: 29,187 Btuh 91 %
Total latent gain: 2,759 Btuh 9 ok
Total cooling required with outside air: 31,946 Btuh 2.662 Tons (based on sensible + latent)
3.159 Tons (based on 77% sensible capacity)
Notes
Calculations are based on 7th edition of ACCA Manual J.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads.
RHVAC - Residential & Light Commercial HVAC Loads Program
Gemaire Distributors, Inc.
Miami, FL 33122
Total Building Summary Loads
Subtotals for structure:
Active People:
Inactive People:
Appliances:
Lighting:
Ductwork:
Infiltration: Winter CFM: 201.6, Summer CFM: 44.8
Ventilation: Winter CFM: 0.0, Summer CFM: 0.0
Sensible Gain Total:
Temperature Swing Multiplier:
Building Load Totals:
Check Figures
Total Building Supply CFM: 1320
Square feet of room area: 1,600
Building Loads
Total heating required with outside air:
Total sensible gain:
Total latent gain:
Total cooling required with outside air:
Notes
02 -23 -2001
54,046 Btuh
29,187 Btuh
2,759 Btuh
31,946 Btuh
Calculations are based on 7th edition of ACCA Manual J.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads.
Elite Software Development, Inc.
NEW SPLIT SYSTEM AIR CONDITIONER
Area Sen. Lat. Sen. Total
Quan Loss Gain Gain Gain
Component
Description
1C Window Clear Glass Metal Frame 202 7,467 0 6,716 6,716
10D Door Wood Solid Core 63 927 0 654 654
13M Part 8" or 12" Block No Insulation Unfinished 108 882 0 413 413
14A Wall 8" or 12" Block No Insulation Unfinished 1,495 24,399 0 11,666 11,666
16D Ceiling R -19 Insulation 1,600 2,714 0 3,646 3,646
19A Floor Over Basement/Encl Crawl Hardwood No Insulation 1,600 7,987 0 0 0
5,068 44,376 0 23,095 23,095
0 0 0 0 0
6 0 900 1,500 2,400
0 0 0 1,200 1,200
0 0 0
0 2,574 0 2,653 2,653
265 7,096 1,859 739 2,598
0 0 0 0 0
29,187
X1.00
54,046 2,759 29,187 31,946
CFM per square foot: 0.825
Square feet per ton: 506.527
54.046 M B H
91 %
9 %
2.662 Tons (based on sensible + latent)
3.159 Tons (based on 77% sensible capacity)
RHVAC - Residential & Light Commercial HVAC Loads Program
Gemaire Distributors, Inc.
Miami, FL 33122
Room Load Summary Reports
System #1 Room Load Summary
Room Area
No Description SF
-- -Zone 1 - --
1 Whole House 1600
System 1 Totals 1600
54,046
Net Required:
Recommended:
Actual:
Type:
Model:
Brand:
Efficiency:
Blower CFM:
Capacity:
Sensible Capacity:
Latent Capacity:
System #1 Cooling System Summary
System #1 Equipment Data
54,046
Cooling
Tons
2.662
3.159
3.333
Htg Htg
Sens Nom
Btuh CFM
Sensible /Latent
Split
91%/9%
77 %123%
75 %/25%
Heating System
n/a
n/a
02 -23 -2001
Run Clg
Duct Sens
Size Btuh
1,320 7 -8 29,187
1,320 29,187
Sensible
Btu h
29,187
29,187
30,000
Elite Software Development. Inc.
NEW SPLIT SYSTEM AIR CONDITIONER
Clg Clg Zone Clg Air
Lat Nom Adj Adj Sys
Btuh CFM Fact CFM CFM
2,759 1,320 1.18 1,562 1,320
2,759 1,320 1,562 1,320
Main Trunk Size: 18x14 in.
Latent
Btuh
2,759
8,718
10,000
Cooling System
Standard NC
38BR042 -30 / FK4BNB006
CARRIER
14.0
1400
40,000 Btuh
30,000 Btuh
10,000 Btuh
Total
Btuh
31,946
37,905
40,000
HVAC DESIGN REQUIRES:
date: 02 -23 -01
REVISIONS:
Duct Smoke Detector
A/H
X
scale:
1/4' = 1' -0"
by:
ERA TECHNICAL
1320
SERVICES
ALL AMERICA
AIR CONDITIONING
7901 W. 25 AVE.
HIALEAH, FL.
33016
305- 888 -9641
Fire Stopping
HVAC DESIGN REQUIRES:
YES
,
NO
Duct Smoke Detector
A/H
X
Fire Damper(s)
SEE PLAN
X
Smoke Damper(s)
1320
X
Fire Rated Enclosure
0
x
Fire Rated Ft/Ceiling Assembly
0.2
X
Fire Stopping
1/3 4.4
X
Smoke Control
COOLING COIL
X
wt; EUUIPMENT SCHEDULE
z
<
UNIT NUMBER
A/H
AREA SERVED
SEE PLAN
TOTAL AIR SUPPLY
1320
OUTSIDE AIR CFM
0
EXTERNAL STATIC PRESSURE -IN W.G.-
0.2
FAN MOTOR HP /FLA
1/3 4.4
ELEC. CHARACTERISTICS V/ Hz/0
208/230 -60 -01
COOLING COIL
COOL. COIL CAP. - BTU /HR-
40000
TOTAL SENSIBLE HEAT - BTU /HR-
30160
ENT. AIR TEMP. -F DB/ F WB- °
MODEL NUMBER
UNIT MANUFACTURER
CARRIER
MODEL NUMBER
FK4BNB006
Iv I
WEIGHT -Ibs.-
MCA/MFS COOLING
MCA/MFS HEATING
UNIT NUMBER
C/U
NG UNI1
LOCATION
ON SLAB
AMBIENT TEMP. °F
9
REFRIGERANT
COMPR. /COND. FAN FLA
DO(
ELEC. CHARACTERISTICS V /Hz/0
208/230 -60 -01
UNIT MANUFACTURER
CARRIER
MODEL NUMBER
38BR042 -30
WEIGHT - Ibs.-
REMARKS
SYSTEM (S)EER
14.0
LIQUID /SUCTION SIZE -IN
3/8" X 7/8"
ELECTRIC HEATER -KW-
10
i
CONDENSING UNIT INSTALLATION DETAIL.
n.t.s.
liquid and
suction lines
(4) 14 gauge tie
down straps.
1 -1/2" pin with washer.
4" concrete slab.
z _ property line: 8' -7"
40' -10"
anchored to
concrete slab.
SEE DETAIL.
refrigerant and
drain lines.
SEE A/H INST.
DETAIL.
AII
r_ -
I
InsIr
NH
i7
A
1
AIVAINv ANN
AV
40CFM
8X4"
04 "flex
DEN FAMILY ROOM
06 "flex
160CFM
10X6"
.41/
AMYAMTAII
■
Asripr .arAi■
•
1
y` .11/41
•
160CFM
/ 10X6"
40CFM
8X4"
04 "flex -/'
BATH
08 "flex
BEDROOM 2
200CFM
10X8"
BEDROOM 1
1
06 "flex
/
08 "flex
\ 16x14"
duct board
COVERED TERRACE
08 "flex
LIVING ROOM
200CFM
10X8"
47'
010 "flex
1Ox1Ox10"
duct board
WINDOW SCHEDULE:
10 4.5 S.F. 0 16 S.F.
20 9 S.F. 0 30 S.F,
® 12 S.F.
04 "flex-
12x12x12"
duct board
L.
WIC
160CFM
10X6"
06 "flex
160CFM
10X6"
06 "flex 1
DINING ROOM
160CFM
10X6"
BEDROOM 3
BATH
40CFM
8X4"
r
3/8" OD liquid line
through crawl space
to C /U.
0 7/8" OD suction line
through crawl space to
C/U insulated with
armafiex 7/8 "x1/2 ".
03/4" PVC drain line —
w/P trap through crawl
space to soil area.
AIR HANDLER INSTALLATION
n.t.s
2 "X4" wood
ALL DUCTWORK TO BE R -6.
ALL DIFFUSERS ARE CEILING TYPE.
U
w
a
2 L.L.
Q
1- W Et
0 O
2
W
U
J
Q 2
CONSULTANT:
PAGE #: 1 of 1
new split system air conditioner
Qs t t t 40t.: $ 40b0 V
a ,
rtigAttl
Ufu
1 0 0 IIVID.•.,.... .oit ogi et t
{ .1 3 t
fs}C�t �,atjf ti
4
ti
tl
. .h.
£C (i o) aft') 91?4 S = t0 f30 Pid
` S cltieC"� E 1,3'
o- . ., j+ P
ip
(s 4. fr) J i*1 Q.kk )1 lJ�(ES.
VP.*
. ,
ki
A Koos- 6.0
r: ot 1•1 : r.
tat g.
° Staa
AI (iv
uvict V p id4 a ti
S"PQ t t. 40,A LA3 5
t4 K' 2ii ", tUV 4 - t0. VI 3t
�i
f'44
sL RO�'!
A0e!'t
r f
i
,Y'